HIRSCHMANN-WAN-STATUS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY, Integer32
|
|
FROM SNMPv2-SMI -- RFC 2578
|
|
hmWanMgmt
|
|
FROM HIRSCHMANN-WAN-MIB;
|
|
|
|
hmWanStatusMib MODULE-IDENTITY
|
|
LAST-UPDATED "201502130000Z" -- Februar 13, 2015
|
|
ORGANIZATION "Hirschmann Automation and Control GmbH"
|
|
CONTACT-INFO
|
|
"Postal: Stuttgarter Str. 45-51
|
|
72654 Neckartenzlingen
|
|
Germany
|
|
Phone: +49 7127 140
|
|
E-mail: hac.support@belden.com"
|
|
DESCRIPTION
|
|
"Copyright (C) 2015. All Rights Reserved."
|
|
REVISION "201502130000Z" -- Februar 13, 2015
|
|
DESCRIPTION
|
|
"Initial version."
|
|
::= { hmWanMgmt 3 }
|
|
|
|
hmWanStatusMBusOverload1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (0),
|
|
yes (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
::= { hmWanStatusMib 1 }
|
|
|
|
hmWanStatusMBusOverload2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (0),
|
|
yes (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
::= { hmWanStatusMib 2 }
|
|
|
|
hmWanStatusTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
::= { hmWanStatusMib 3 }
|
|
|
|
hmWanStatusVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
::= { hmWanStatusMib 4 }
|
|
|
|
END
|