806 lines
28 KiB
Plaintext
806 lines
28 KiB
Plaintext
-- =================================================================
|
|
-- Copyright (C) 2003 by H3C TECHNOLOGIES. All rights reserved
|
|
--
|
|
-- Description:This MIB file is used for management of userlog
|
|
-- information.
|
|
-- Reference:
|
|
-- Version: V1.1
|
|
-- History:
|
|
-- V1.0
|
|
-- 31st Mar 2003
|
|
-- tianli, initial version
|
|
-- V1.1 2005-07-05
|
|
-- Modify value range of hwUserlogNatAclNumber and hwUserlogFlowAclNumber
|
|
-- by tanbo02122.
|
|
-- Update file format by gaolong.
|
|
-- =================================================================
|
|
HUAWEI-USERLOG-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
huawei,huaweiMgmt,huaweiDatacomm
|
|
FROM HUAWEI-3COM-OID-MIB
|
|
OBJECT-GROUP, MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF
|
|
IpAddress, Integer32, Counter32, OBJECT-TYPE,
|
|
MODULE-IDENTITY
|
|
FROM SNMPv2-SMI;
|
|
|
|
|
|
hwUserLogMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200304100000Z" -- April 10, 2003 at 00:00 GMT
|
|
ORGANIZATION
|
|
"Hangzhou H3C Tech. Co., Ltd."
|
|
CONTACT-INFO
|
|
"Platform Team Hangzhou H3C Tech. Co., Ltd.
|
|
Hai-Dian District Beijing P.R. China
|
|
http://www.h3c.com
|
|
Zip:100085
|
|
"
|
|
DESCRIPTION
|
|
"The HUAWEI-USERLOG-MIB contains objects to
|
|
Manage configuration and Monitor running state
|
|
for userlog feature."
|
|
::= { huaweiDatacomm 18 }
|
|
|
|
|
|
hwUserlogObjects OBJECT IDENTIFIER ::= { hwUserLogMIB 1 }
|
|
|
|
|
|
hwUserlogNatObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 1 }
|
|
|
|
|
|
hwUserlogNatVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NAT LOG version. Currently only version 1 is developed."
|
|
::= { hwUserlogNatObjects 1 }
|
|
|
|
|
|
hwUserlogNatSyslog OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
NAT LOG format.
|
|
If 1, LOG format is sysLog.
|
|
If 0, LOG format is UDP packet.
|
|
UDP packet is the default format, and is recommended.
|
|
"
|
|
::= { hwUserlogNatObjects 2 }
|
|
|
|
|
|
hwUserlogNatSourceIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Source IP address of NAT LOG UDP packet."
|
|
::= { hwUserlogNatObjects 3 }
|
|
|
|
|
|
hwUserlogNatFlowBegin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Log the NAT flow when it is created.
|
|
If 1, this function is enabled.
|
|
If 0, this function is disabled.
|
|
This function will be used when real-time monitor required.
|
|
"
|
|
::= { hwUserlogNatObjects 4 }
|
|
|
|
|
|
hwUserlogNatActiveTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The active time for long-time existed NAT flow.
|
|
Unit: minute. Range: 10 minutes ~ 120 minutes.
|
|
When setting it, NAT flow can be logged after an interval of
|
|
active time.
|
|
This function will be used when real-time monitor required.
|
|
The default value 0 means real-time monitor function is disabled.
|
|
"
|
|
::= { hwUserlogNatObjects 5 }
|
|
|
|
|
|
hwUserlogNatSlotCfgInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwUserlogNatSlotCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of NAT LOG configuration information for the
|
|
specified slot."
|
|
::= { hwUserlogNatObjects 6 }
|
|
|
|
|
|
hwUserlogNatSlotCfgInfoEntry OBJECT-TYPE
|
|
SYNTAX HwUserlogNatSlotCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NAT LOG Configuration Information Entry for a slot."
|
|
INDEX { hwUserlogNatCfgSlotNumber }
|
|
::= { hwUserlogNatSlotCfgInfoTable 1 }
|
|
|
|
|
|
HwUserlogNatSlotCfgInfoEntry ::=
|
|
SEQUENCE {
|
|
hwUserlogNatCfgSlotNumber
|
|
Integer32,
|
|
hwUserlogNatEnable
|
|
Integer32,
|
|
hwUserlogNatAclNumber
|
|
Integer32,
|
|
hwUserlogNatHostAddress
|
|
IpAddress,
|
|
hwUserlogNatUdpPort
|
|
Integer32
|
|
}
|
|
|
|
hwUserlogNatCfgSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot number. Specify which slot is configured with NAT LOG. "
|
|
::= { hwUserlogNatSlotCfgInfoEntry 1 }
|
|
|
|
|
|
hwUserlogNatEnable OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The NAT LOG feature Enable status.
|
|
If 1, NAT LOG is enbled.
|
|
If 0, NAT LOG is disabled.
|
|
"
|
|
::= { hwUserlogNatSlotCfgInfoEntry 2 }
|
|
|
|
|
|
hwUserlogNatAclNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Access-list number.
|
|
The value 0 means no ACL is specified.
|
|
Only when NAT LOG is enabled, can ACL be configured.
|
|
Only NAT flow which match the ACL will be logged.
|
|
"
|
|
::= { hwUserlogNatSlotCfgInfoEntry 3 }
|
|
|
|
|
|
hwUserlogNatHostAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of NAT LOG server. "
|
|
::= { hwUserlogNatSlotCfgInfoEntry 4 }
|
|
|
|
|
|
hwUserlogNatUdpPort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UDP Port Number of NAT LOG UDP packet."
|
|
::= { hwUserlogNatSlotCfgInfoEntry 5 }
|
|
|
|
|
|
hwUserlogNatSlotRunInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwUserlogNatSlotRunInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of NAT LOG running information for the specified slot."
|
|
::= { hwUserlogNatObjects 7 }
|
|
|
|
|
|
hwUserlogNatSlotRunInfoEntry OBJECT-TYPE
|
|
SYNTAX HwUserlogNatSlotRunInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NAT LOG Running Information Entry for a slot."
|
|
INDEX { hwUserlogNatRunSlotNumber }
|
|
::= { hwUserlogNatSlotRunInfoTable 1 }
|
|
|
|
|
|
HwUserlogNatSlotRunInfoEntry ::=
|
|
SEQUENCE {
|
|
hwUserlogNatRunSlotNumber
|
|
Integer32,
|
|
hwUserlogNatTotalEntries
|
|
Counter32,
|
|
hwUserlogNatTotalPackets
|
|
Counter32,
|
|
hwUserlogNatFailedEntries
|
|
Counter32,
|
|
hwUserlogNatFailedPackets
|
|
Counter32,
|
|
hwUserlogNatClearRunStat
|
|
Integer32
|
|
}
|
|
|
|
hwUserlogNatRunSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot number. Specify on which slot the NAT LOG statistics
|
|
displayed."
|
|
::= { hwUserlogNatSlotRunInfoEntry 1 }
|
|
|
|
|
|
hwUserlogNatTotalEntries OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of NAT flow entries which are logged."
|
|
::= { hwUserlogNatSlotRunInfoEntry 2 }
|
|
|
|
|
|
hwUserlogNatTotalPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of NAT LOG UDP packets generated by the router."
|
|
::= { hwUserlogNatSlotRunInfoEntry 3 }
|
|
|
|
|
|
hwUserlogNatFailedEntries OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of NAT flow entries failed in outputting."
|
|
::= { hwUserlogNatSlotRunInfoEntry 4 }
|
|
|
|
|
|
hwUserlogNatFailedPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of NAT LOG UDP packets failed in outputting."
|
|
::= { hwUserlogNatSlotRunInfoEntry 5 }
|
|
|
|
|
|
hwUserlogNatClearRunStat OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Clear the running statistics for NAT LOG. Write-only.
|
|
If 1, the running statistics for NAT LOG is resetted.
|
|
Other value is invalid.
|
|
"
|
|
::= { hwUserlogNatSlotRunInfoEntry 6 }
|
|
|
|
|
|
hwUserlogFlowObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 2 }
|
|
|
|
|
|
hwUserlogFlowVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BAS FLOW LOG version. Currently only version 1 is developed."
|
|
::= { hwUserlogFlowObjects 1 }
|
|
|
|
|
|
hwUserlogFlowSyslog OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
BAS FLOW LOG format.
|
|
If 1, LOG format is sysLog.
|
|
If 0, LOG format is UDP packet.
|
|
UDP packet is the default format, and is recommended.
|
|
"
|
|
::= { hwUserlogFlowObjects 2 }
|
|
|
|
|
|
hwUserlogFlowSourceIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Source IP address of BAS FLOW LOG UDP packet."
|
|
::= { hwUserlogFlowObjects 3 }
|
|
|
|
|
|
hwUserlogFlowFlowBegin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Log the BAS flow when it is created.
|
|
If 1, this function is enabled.
|
|
If 0, this function is disabled.
|
|
This function will be used when real-time monitor required.
|
|
"
|
|
::= { hwUserlogFlowObjects 4 }
|
|
|
|
|
|
hwUserlogFlowActiveTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The active time for long-time existed BAS flow.
|
|
Unit: minute. Range: 10 minutes ~ 120 minutes.
|
|
When setting it, BAS flow can be logged after an internal of
|
|
active time.
|
|
This function will be used when real-time monitor required.
|
|
The default value 0 means real-time monitor function is disabled.
|
|
"
|
|
::= { hwUserlogFlowObjects 5 }
|
|
|
|
|
|
hwUserlogFlowSlotCfgInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwUserlogFlowSlotCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of BAS FLOW LOG configuration information for the
|
|
specified slot."
|
|
::= { hwUserlogFlowObjects 6 }
|
|
|
|
|
|
hwUserlogFlowSlotCfgInfoEntry OBJECT-TYPE
|
|
SYNTAX HwUserlogFlowSlotCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BAS FLOW LOG Configuration Information Entry for a slot."
|
|
INDEX { hwUserlogFlowCfgSlotNumber }
|
|
::= { hwUserlogFlowSlotCfgInfoTable 1 }
|
|
|
|
|
|
HwUserlogFlowSlotCfgInfoEntry ::=
|
|
SEQUENCE {
|
|
hwUserlogFlowCfgSlotNumber
|
|
Integer32,
|
|
hwUserlogFlowEnable
|
|
Integer32,
|
|
hwUserlogFlowAclNumber
|
|
Integer32,
|
|
hwUserlogFlowHostAddress
|
|
IpAddress,
|
|
hwUserlogFlowUdpPort
|
|
Integer32
|
|
}
|
|
|
|
hwUserlogFlowCfgSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot number. Specify which slot is configured with BAS FLOW LOG."
|
|
::= { hwUserlogFlowSlotCfgInfoEntry 1 }
|
|
|
|
|
|
hwUserlogFlowEnable OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The BAS FLOW LOG feature Enable status.
|
|
If 1, BAS FLOW LOG is enbled.
|
|
If 0, BAS FLOW LOG is disabled.
|
|
"
|
|
::= { hwUserlogFlowSlotCfgInfoEntry 2 }
|
|
|
|
|
|
hwUserlogFlowAclNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Access-list number.
|
|
The value 0 means no ACL is specified.
|
|
Only when BAS FLOW LOG is enabled, can ACL be configured.
|
|
Only BAS flow which match the ACL will be logged.
|
|
"
|
|
::= { hwUserlogFlowSlotCfgInfoEntry 3 }
|
|
|
|
|
|
hwUserlogFlowHostAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of BAS FLOW LOG server. "
|
|
::= { hwUserlogFlowSlotCfgInfoEntry 4 }
|
|
|
|
|
|
hwUserlogFlowUdpPort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UDP Port Number of BAS FLOW LOG UDP packet."
|
|
::= { hwUserlogFlowSlotCfgInfoEntry 5 }
|
|
|
|
|
|
hwUserlogFlowSlotRunInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwUserlogFlowSlotRunInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of BAS FLOW LOG running information for the specified slot."
|
|
::= { hwUserlogFlowObjects 7 }
|
|
|
|
|
|
hwUserlogFlowSlotRunInfoEntry OBJECT-TYPE
|
|
SYNTAX HwUserlogFlowSlotRunInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Running Information Entry for a slot."
|
|
INDEX { hwUserlogFlowRunSlotNumber }
|
|
::= { hwUserlogFlowSlotRunInfoTable 1 }
|
|
|
|
|
|
HwUserlogFlowSlotRunInfoEntry ::=
|
|
SEQUENCE {
|
|
hwUserlogFlowRunSlotNumber
|
|
Integer32,
|
|
hwUserlogFlowTotalEntries
|
|
Counter32,
|
|
hwUserlogFlowTotalPackets
|
|
Counter32,
|
|
hwUserlogFlowFailedEntries
|
|
Counter32,
|
|
hwUserlogFlowFailedPackets
|
|
Counter32,
|
|
hwUserlogFlowClearRunStat
|
|
Integer32
|
|
}
|
|
|
|
hwUserlogFlowRunSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot number. Specify on which slot the BAS FLOW LOG
|
|
statistics displayed."
|
|
::= { hwUserlogFlowSlotRunInfoEntry 1 }
|
|
|
|
|
|
hwUserlogFlowTotalEntries OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BAS FLOW Entries which are logged."
|
|
::= { hwUserlogFlowSlotRunInfoEntry 2 }
|
|
|
|
|
|
hwUserlogFlowTotalPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of FLOW LOG UDP packet generated by the router."
|
|
::= { hwUserlogFlowSlotRunInfoEntry 3 }
|
|
|
|
|
|
hwUserlogFlowFailedEntries OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BAS FLOW entries failed in outputting. "
|
|
::= { hwUserlogFlowSlotRunInfoEntry 4 }
|
|
|
|
|
|
hwUserlogFlowFailedPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BAS FLOW LOG UDP packet failed in outputting."
|
|
::= { hwUserlogFlowSlotRunInfoEntry 5 }
|
|
|
|
|
|
hwUserlogFlowClearRunStat OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Clear the running statistics for FLOW LOG. Write-only.
|
|
If 1, the running statistics for FLOW LOG is resetted.
|
|
Other value is invalid.
|
|
"
|
|
::= { hwUserlogFlowSlotRunInfoEntry 6 }
|
|
|
|
|
|
hwUserlogAccessObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 3 }
|
|
|
|
|
|
hwUserlogAccessVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BAS ACCESS LOG version. Currently only version 1 is developed."
|
|
::= { hwUserlogAccessObjects 1 }
|
|
|
|
|
|
hwUserlogAccessSyslog OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
BAS ACCESS LOG format.
|
|
If 1, LOG format is sysLog;
|
|
If 0, LOG format is UDP packet.
|
|
UDP packet is the default format, and is recommended.
|
|
"
|
|
::= { hwUserlogAccessObjects 2 }
|
|
|
|
|
|
hwUserlogAccessSourceIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Source IP address of BAS ACCESS LOG UDP packet."
|
|
::= { hwUserlogAccessObjects 3 }
|
|
|
|
|
|
hwUserlogAccessSlotCfgInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwUserlogAccessSlotCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of BAS ACCESS LOG configuration information for the specified slot."
|
|
::= { hwUserlogAccessObjects 4 }
|
|
|
|
|
|
hwUserlogAccessSlotCfgInfoEntry OBJECT-TYPE
|
|
SYNTAX HwUserlogAccessSlotCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BAS ACCESS LOG Configuration Information Entry for a slot."
|
|
INDEX { hwUserlogAccessCfgSlotNumber }
|
|
::= { hwUserlogAccessSlotCfgInfoTable 1 }
|
|
|
|
|
|
HwUserlogAccessSlotCfgInfoEntry ::=
|
|
SEQUENCE {
|
|
hwUserlogAccessCfgSlotNumber
|
|
Integer32,
|
|
hwUserlogAccessEnable
|
|
Integer32,
|
|
hwUserlogAccessHostAddress
|
|
IpAddress,
|
|
hwUserlogAccessUdpPort
|
|
Integer32
|
|
}
|
|
|
|
hwUserlogAccessCfgSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot number. Specify which slot is configured with BAS ACCESS LOG."
|
|
::= { hwUserlogAccessSlotCfgInfoEntry 1 }
|
|
|
|
|
|
hwUserlogAccessEnable OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The BAS ACCESS LOG feature Enable status.
|
|
If 1, BAS ACCESS LOG is enbled.
|
|
If 0, BAS ACCESS LOG is disabled.
|
|
"
|
|
::= { hwUserlogAccessSlotCfgInfoEntry 2 }
|
|
|
|
|
|
hwUserlogAccessHostAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of BAS ACCESS LOG server."
|
|
::= { hwUserlogAccessSlotCfgInfoEntry 3 }
|
|
|
|
|
|
hwUserlogAccessUdpPort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UDP Port Number of BAS ACCESS LOG UDP packet."
|
|
::= { hwUserlogAccessSlotCfgInfoEntry 4 }
|
|
|
|
|
|
hwUserlogAccessSlotRunInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwUserlogAccessSlotRunInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of BAS ACCESS LOG running information for the specified slot."
|
|
::= { hwUserlogAccessObjects 5 }
|
|
|
|
|
|
hwUserlogAccessSlotRunInfoEntry OBJECT-TYPE
|
|
SYNTAX HwUserlogAccessSlotRunInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Running Information Entry for a slot."
|
|
INDEX { hwUserlogAccessRunSlotNumber }
|
|
::= { hwUserlogAccessSlotRunInfoTable 1 }
|
|
|
|
|
|
HwUserlogAccessSlotRunInfoEntry ::=
|
|
SEQUENCE {
|
|
hwUserlogAccessRunSlotNumber
|
|
Integer32,
|
|
hwUserlogAccessTotalEntries
|
|
Counter32,
|
|
hwUserlogAccessTotalPackets
|
|
Counter32,
|
|
hwUserlogAccessFailedEntries
|
|
Counter32,
|
|
hwUserlogAccessFailedPackets
|
|
Counter32,
|
|
hwUserlogAccessClearRunStat
|
|
Integer32
|
|
}
|
|
|
|
hwUserlogAccessRunSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot number. Specify on which slot the BAS ACCESS LOG statistics displayed."
|
|
::= { hwUserlogAccessSlotRunInfoEntry 1 }
|
|
|
|
|
|
hwUserlogAccessTotalEntries OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BAS ACCESS Records which are logged."
|
|
::= { hwUserlogAccessSlotRunInfoEntry 2 }
|
|
|
|
|
|
hwUserlogAccessTotalPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of ACCESS LOG UDP packet generated by the router."
|
|
::= { hwUserlogAccessSlotRunInfoEntry 3 }
|
|
|
|
|
|
hwUserlogAccessFailedEntries OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BAS ACCESS entries failed in outputting."
|
|
::= { hwUserlogAccessSlotRunInfoEntry 4 }
|
|
|
|
|
|
hwUserlogAccessFailedPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BAS ACCESS LOG UDP packet failed in outputting."
|
|
::= { hwUserlogAccessSlotRunInfoEntry 5 }
|
|
|
|
|
|
hwUserlogAccessClearRunStat OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Clear the running statistics for ACCESS LOG. Write-only.
|
|
If 1, the running statistics for ACCESS LOG is resetted.
|
|
Other value is invalid.
|
|
"
|
|
::= { hwUserlogAccessSlotRunInfoEntry 6 }
|
|
|
|
|
|
hwUserlogNotifications OBJECT IDENTIFIER ::= { hwUserLogMIB 2 }
|
|
|
|
|
|
hwUserlogConformance OBJECT IDENTIFIER ::= { hwUserLogMIB 3 }
|
|
|
|
|
|
hwUserlogCompliances OBJECT IDENTIFIER ::= { hwUserlogConformance 1 }
|
|
|
|
|
|
hwUserlogCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement the
|
|
Userlog mib."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { hwUserlogMandatoryGroup }
|
|
::= { hwUserlogCompliances 1 }
|
|
|
|
|
|
hwUserlogGroups OBJECT IDENTIFIER ::= { hwUserlogConformance 2 }
|
|
|
|
|
|
hwUserlogMandatoryGroup OBJECT-GROUP
|
|
OBJECTS { hwUserlogNatEnable, hwUserlogNatHostAddress, hwUserlogNatUdpPort,
|
|
hwUserlogFlowEnable, hwUserlogFlowHostAddress, hwUserlogFlowUdpPort,
|
|
hwUserlogAccessEnable, hwUserlogAccessHostAddress, hwUserlogAccessUdpPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing mandatory Userlog information."
|
|
::= { hwUserlogGroups 1 }
|
|
|
|
|
|
hwUserlogConfigGroup OBJECT-GROUP
|
|
OBJECTS { hwUserlogNatVersion, hwUserlogNatSyslog, hwUserlogNatSourceIP,
|
|
hwUserlogNatFlowBegin, hwUserlogNatActiveTime, hwUserlogNatCfgSlotNumber,
|
|
hwUserlogNatEnable, hwUserlogNatAclNumber, hwUserlogNatHostAddress,
|
|
hwUserlogNatUdpPort, hwUserlogFlowVersion, hwUserlogFlowSyslog,
|
|
hwUserlogFlowSourceIP, hwUserlogFlowFlowBegin, hwUserlogFlowActiveTime,
|
|
hwUserlogFlowCfgSlotNumber, hwUserlogFlowEnable, hwUserlogFlowAclNumber,
|
|
hwUserlogFlowHostAddress, hwUserlogFlowUdpPort, hwUserlogAccessVersion,
|
|
hwUserlogAccessSyslog, hwUserlogAccessSourceIP, hwUserlogAccessCfgSlotNumber,
|
|
hwUserlogAccessEnable, hwUserlogAccessHostAddress, hwUserlogAccessUdpPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All configurable parameters of Userlog feature."
|
|
::= { hwUserlogGroups 2 }
|
|
|
|
|
|
hwUserlogInfoGroup OBJECT-GROUP
|
|
OBJECTS { hwUserlogNatTotalEntries, hwUserlogNatTotalPackets,
|
|
hwUserlogNatFailedEntries, hwUserlogNatFailedPackets,
|
|
hwUserlogFlowTotalEntries, hwUserlogFlowTotalPackets,
|
|
hwUserlogFlowFailedEntries, hwUserlogFlowFailedPackets,
|
|
hwUserlogAccessTotalEntries, hwUserlogAccessTotalPackets,
|
|
hwUserlogAccessFailedEntries, hwUserlogAccessFailedPackets
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All running information of Userlog feature."
|
|
::= { hwUserlogGroups 3 }
|
|
|
|
END
|