-- Copyright (c) 2004-2015 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: Port Extender (PEX) information MIB
-- Reference:
-- Version: V1.2
-- History:
-- V1.0 2012-11-12 Initial version by Yang Fan
-- V1.1 2014-03-31 Changed MIB node name to PEX by zushuzhi
-- V1.2 2015-10-15 Added h3cPexDeviceInfoTable and h3cPexTopoTable
-- by zushuzhi
-- ============================================================================
H3C-PEX-MIB DEFINITIONS ::= BEGIN
IMPORTS
h3cCommon
FROM HUAWEI-3COM-OID-MIB
entPhysicalIndex, entPhysicalDescr
FROM ENTITY-MIB
Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
RowStatus, DisplayString
FROM SNMPv2-TC;
h3cPex MODULE-IDENTITY
LAST-UPDATED "201510151129Z" -- 15th October, 2015 at 11:29 GMT
ORGANIZATION
"Hangzhou H3C Technologies Co., Ltd."
CONTACT-INFO
"Platform Team H3C Technologies Co., Ltd.
Haidian District Beijing P.R. China
Http://www.h3c.com
Zip:100085"
DESCRIPTION
"This MIB is used to manage Port Extender (PEX)
information. This MIB is applicable to products that support PEX."
REVISION "201510151129Z"
DESCRIPTION
"Added h3cPexDeviceInfoTable and h3cPexTopoTable."
REVISION "201211121129Z"
DESCRIPTION
"Initial version of this MIB module."
::= { h3cCommon 129 }
-- PEX Specification Information
h3cPexSpecInfo OBJECT IDENTIFIER ::= { h3cPex 1 }
h3cPexPortMinId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lowest PEX port ID that can be used to uniquely identify a PEX port."
::= { h3cPexSpecInfo 1 }
h3cPexPortMaxId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Highest PEX port ID that can be used to uniquely identify a PEX port."
::= { h3cPexSpecInfo 2 }
h3cPexMinAssociateId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lowest ID that can be assigned to a port extender (PEX)."
::= { h3cPexSpecInfo 3 }
h3cPexMaxAssociateId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Highest ID that can be assigned to a PEX."
::= { h3cPexSpecInfo 4 }
h3cPexMaxPortPerPexPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of ports that can be bound to a PEX port."
::= { h3cPexSpecInfo 5 }
-- PEX Information
h3cPexTable OBJECT IDENTIFIER ::= { h3cPex 2 }
h3cPexPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPexPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects used to configure the PEX ports."
::= { h3cPexTable 1 }
h3cPexPortEntry OBJECT-TYPE
SYNTAX H3cPexPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a PEX."
INDEX
{
h3cPexPortId
}
::= { h3cPexPortTable 1 }
H3cPexPortEntry ::= SEQUENCE
{
h3cPexPortId Integer32,
h3cPexPortAssociateId Integer32,
h3cPexPortEntPhysicalIndex Integer32,
h3cPexPortDescr DisplayString,
h3cPexPortStatus INTEGER,
h3cPexPortRowStatus RowStatus
}
h3cPexPortId OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"ID that can be used to uniquely identify a PEX port. The value range
is h3cPexPortMinId to h3cPexPortMaxId."
::= { h3cPexPortEntry 1 }
h3cPexPortAssociateId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ID assigned to a PEX. The
value range is h3cPexMinAssociateId to h3cPexMaxAssociateId.
The value is 0xffff if the PEX is not assigned an ID.
For a successful configuration, the ID should not be used by any
other PEX."
DEFVAL { 65535 }
::= { h3cPexPortEntry 2 }
h3cPexPortEntPhysicalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Entity index of a PEX in the IRF. A value of zero
indicates that the PEX is not online."
DEFVAL { 0 }
::= { h3cPexPortEntry 3 }
h3cPexPortDescr OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..79))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Description for the PEX port. The default value is
'pex-port XXXX', where 'XXXX' is h3cPexPortId.
Writing a zero-length string to this object resets the value to the
default."
::= { h3cPexPortEntry 4 }
h3cPexPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
offline(1),
loading(2),
online(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the PEX.
offline: The PEX is absent or its configuration is incomplete.
loading: The PEX is loading software.
online: The PEX is operating correctly."
DEFVAL { offline }
::= { h3cPexPortEntry 5 }
h3cPexPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The control that allows creation and deletion of entries.
Values include createAndGo, active, and destroy.
If the row to be created or modified already exists,
an error message is returned. If the row to be deleted does not exist,
a success message is returned."
::= { h3cPexPortEntry 6 }
-- PEX PhyPort Information
h3cPexPhyPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPexPhyPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects used to manage physical ports
that can be bound or are already bound to a PEX port."
::= { h3cPexTable 2 }
h3cPexPhyPortEntry OBJECT-TYPE
SYNTAX H3cPexPhyPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a physical port that can be bound to or
has been bound to a PEX port."
INDEX
{
entPhysicalIndex
}
::= { h3cPexPhyPortTable 1 }
H3cPexPhyPortEntry ::= SEQUENCE
{
h3cPexPhyPortStatus INTEGER,
h3cPexPhyPortBelongToPexPort Integer32,
h3cPexPhyPortNeighborEntIndex Integer32
}
h3cPexPhyPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
down(2),
blocked(3),
forwarding(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the physical port that is bound to a PEX port.
The following are status values:
unknown: The physical port is not bound to any PEX port.
down: The physical port is link down.
blocked: The physical port is blocked and cannot forward traffic.
forwarding: The physical port can forwarding traffic."
DEFVAL { unknown }
::= { h3cPexPhyPortEntry 1 }
h3cPexPhyPortBelongToPexPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ID of the PEX port to which the physical port belongs. The value
range is h3cPexPortMinId to h3cPexPortMaxId. A value of zero
indicates that the port doesn't belong to any PEX port."
DEFVAL { 0 }
::= { h3cPexPhyPortEntry 2 }
h3cPexPhyPortNeighborEntIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Entity index of a physical port that connects the PEX to the parent
device. This value is identical to entPhysicalIndex in ENTITY-MIB.
A value of zero indicates that the physical port is not bound to any
PEX port or is not up."
::= { h3cPexPhyPortEntry 3 }
-- PEX Topology Information
h3cPexDeviceInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPexDeviceInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains online PEXs in the IRF system."
::= { h3cPexTable 3 }
h3cPexDeviceInfoEntry OBJECT-TYPE
SYNTAX H3cPexDeviceInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a PEX in the IRF system. The index is the PEX
entity index."
INDEX
{
entPhysicalIndex
}
::= { h3cPexDeviceInfoTable 1 }
H3cPexDeviceInfoEntry ::= SEQUENCE
{
h3cPexDeviceStatus INTEGER,
h3cPexDeviceAssociateId Integer32
}
h3cPexDeviceStatus OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
faulty(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the PEX.
normal: The PEX is operating correctly.
faulty: The PEX is faulty."
::= { h3cPexDeviceInfoEntry 1 }
h3cPexDeviceAssociateId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID assigned to the PEX."
::= { h3cPexDeviceInfoEntry 2 }
h3cPexTopoTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPexTopoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information about the PEX physical ports and
neighbor ports on PEXs."
::= { h3cPexTable 4 }
h3cPexTopoEntry OBJECT-TYPE
SYNTAX H3cPexTopoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a PEX link."
INDEX
{
entPhysicalIndex
}
::= { h3cPexTopoTable 1 }
H3cPexTopoEntry ::= SEQUENCE
{
h3cPexNeighborEntIndex Integer32
}
h3cPexNeighborEntIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Entity index of a PEX in the IRF system."
::= { h3cPexTopoEntry 1 }
-- PEX Traps
h3cPexTraps OBJECT IDENTIFIER ::= { h3cPex 3 }
h3cPexTrapPrefix OBJECT IDENTIFIER ::= { h3cPexTraps 0 }
h3cPexPortOnline NOTIFICATION-TYPE
OBJECTS
{
h3cPexPortId,
h3cPexPortDescr
}
STATUS current
DESCRIPTION
"An h3cPexPortOnline trap is sent when the PEX transitions to
online state."
::= { h3cPexTrapPrefix 1 }
h3cPexPortOffline NOTIFICATION-TYPE
OBJECTS
{
h3cPexPortId,
h3cPexPortDescr
}
STATUS current
DESCRIPTION
"An h3cPexPortOnline trap is sent when the PEX transitions to
offline state."
::= { h3cPexTrapPrefix 2 }
h3cPexPhyPortForwarding NOTIFICATION-TYPE
OBJECTS
{
h3cPexEntPhysicalIndexBind,
entPhysicalDescr
}
STATUS current
DESCRIPTION
"An h3cPexPhyPortForwarding trap is sent when the PEX physical port
transitions to forwarding state."
::= { h3cPexTrapPrefix 3 }
h3cPexPhyPortBlocked NOTIFICATION-TYPE
OBJECTS
{
h3cPexEntPhysicalIndexBind,
entPhysicalDescr
}
STATUS current
DESCRIPTION
"An h3cPexPhyPortBlocked trap is sent when the PEX physical port
transitions from forwarding state to blocked state."
::= { h3cPexTrapPrefix 4 }
h3cPexTrapObjects OBJECT IDENTIFIER ::= { h3cPex 4 }
h3cPexEntPhysicalIndexBind OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This index is identical to entPhysicalIndex in ENTITY-MIB."
::= { h3cPexTrapObjects 1 }
END