-- * Firebrick CPU MIB
-- *
-- * June 2020, Cliff Hones
-- *
-- * Copyright (c) 2020 by Andrews & Arnold
-- *------------------------------------------------
FIREBRICK-CPU-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32,
enterprises
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
InetAddressType,
InetAddress
FROM INET-ADDRESS-MIB
OBJECT-GROUP
FROM SNMPv2-CONF
firebrickNewStyle
FROM FIREBRICK-MIB
;
fbCpuMib MODULE-IDENTITY
LAST-UPDATED "202207150000Z"
ORGANIZATION "Andrews & Arnold Limited"
CONTACT-INFO
"Andrews & Arnold
Unit 1&2, Enterprise Court
Bracknell, Berkshire, RG12 1QS
United Kingdom
Tel: +44 3333 400 999
Email: support@aa.net.uk"
DESCRIPTION "Firebrick CPU usage"
REVISION "202207150000Z"
DESCRIPTION "Additional validation"
REVISION "202006170000Z"
DESCRIPTION "Initial version of this MIB module"
::= { firebrickNewStyle 2 }
fbCpuUsageTable OBJECT-TYPE
SYNTAX SEQUENCE OF FbCpuUsageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"CPU usage for this Firebrick"
::= { fbCpuMib 1 }
fbCpuUsageEntry OBJECT-TYPE
SYNTAX FbCpuUsageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the CPU usage table"
INDEX { fbCpuPeriod, fbCpuCore }
::= { fbCpuUsageTable 1 }
FbCpuUsageEntry ::= SEQUENCE {
fbCpuIRQ Gauge32,
fbCpuAll Gauge32,
fbCpuIRQPeak Gauge32,
fbCpuAllPeak Gauge32,
fbCpuPeriod Integer32,
fbCpuCore Integer32
}
fbCpuPeriod OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The period in minutes covered by this table entry.
Zero indicates that an instantaneous value is required.
Max is 30 minutes."
::= { fbCpuUsageEntry 5 }
fbCpuCore OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The CPU core number covered by this table entry.
The numbering starts at 1, so CPU0 1, CPU1 is 2 etc."
::= { fbCpuUsageEntry 6 }
fbCpuIRQ OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of CPU time spent in interrupt processing for this period.
If period is 0 the instantaneous usage in the last second is used.
Units are 100ths of a percent, so 10000 indicates 100%."
::= { fbCpuUsageEntry 1 }
fbCpuAll OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total percentage of CPU time spent non-idle for this period.
If period is 0 the instantaneous usage in the last second is used.
Units are 100ths of a percent, so 10000 indicates 100%."
::= { fbCpuUsageEntry 2 }
fbCpuIRQPeak OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peak percentage of CPU time in interrupt processing during this period.
If period is 0 the peak usage in the current minute is used.
Units are 100ths of a percent, so 10000 indicates 100%."
::= { fbCpuUsageEntry 3 }
fbCpuAllPeak OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peak percentage of CPU time non-idle during this period.
If period is 0 the peak usage in the current minute is used.
Units are 100ths of a percent, so 10000 indicates 100%."
::= { fbCpuUsageEntry 4 }
END