-- The Ericsson Alarm MIB
--
-- Copyright (c) 2008 by Ericsson AB.
-- All rights reserved.
--
-- This MIB is documented further in EAB/OP-07:0139
--
-- Authors:
-- Stefan Wallin (DataDuctus, primary author)
-- Vincent Desbois
-- Ulf Hallgarn
-- Tomas Jonsson
-- Peter Loborg
-- David Partain
-- Mattias Pettersson A
-- Ingemar Segerberg
-- Johan Wallin
-- Martin Wettergren
--
ERICSSON-ALARM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Unsigned32, Gauge32
FROM SNMPv2-SMI
TruthValue, DateAndTime
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
ericssonModules
FROM ERICSSON-TOP-MIB
EriAdditionalText, EriLargeAdditionalText, EriAlarmType,
EriAlarmSequenceNumber, EriAlarmIndex,
EriAlarmSpecificProblem
FROM ERICSSON-ALARM-TC-MIB
EriProbableCause
FROM ERICSSON-ALARM-PC-MIB
EriMO
FROM ERICSSON-TC-MIB
ResourceId
FROM ALARM-MIB
ItuPerceivedSeverity
FROM ITU-ALARM-TC-MIB
IANAItuEventType
FROM IANA-ITU-ALARM-TC-MIB
snmpTargetBasicGroup
FROM SNMP-TARGET-MIB
snmpNotifyGroup
FROM SNMP-NOTIFICATION-MIB
OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF;
ericssonAlarmMIB MODULE-IDENTITY
LAST-UPDATED "200810170000Z"
ORGANIZATION "Ericsson AB"
CONTACT-INFO
"Email: snmp.mib.contact@ericsson.com "
DESCRIPTION
"See also Documentation and Use of the Ericsson
SNMP Alarm MIB, Document number EAB/OP-07:0139.
This MIB Module is an Ericsson-wide SNMP
interface for managing alarms. Main inputs to
the MIB design are the 3GPP Alarm IRP and X.733.
However, an important restriction is that the MIB
only represents the resource view and not
management activities like acknowledgment, etc.
It describes generic notifications used to send
alarm state changes and a table which represents
the current active alarms in the system. The MIB
supports both stateful alarms and stateless
alarms (that have no clear notification).
Stateless alarms are called alerts.
It is important to identify clearly what is to be
considered the same alarm object instance. All
unique alarm *types* are identified by
'AlarmType'. An AlarmType is a one-to-one
mapping with X.733 EventType, ProbabableCause and
SpecificProblem. A pair of integers are used to
specify the alarm type.
A unique alarm object *instance* is the
combination of managed object and AlarmType. In
this way there, is no ambiguity about how alarm
and alarm clear correlation should be performed:
the same managed object instance and AlarmType
shall be used. The same is true for changing
existing alarm states. Severity and
additionalText can be changed on an existing
alarm.
For stateful alarms there are notifications to
report a new alarm and a cleared alarm. Changing
an alarm is done via the new alarm notification.
The management system shall match the alarm by
using alarm type and managed object instance in
the same way as for clear notifications.
The MIB has different notifications for different
severities in order to support SNMP managers
which maps severities based on notification
identifiers. For stateless alarms, there are
generic notifications to send the alarm raise
with different severities.
A table lists all active alarms so that a manager
can read an initial state and also perform an
alarm resynchronization procedure. There is also
a table of latest stateless alarms. Since the
stateless alarms do not have a corresponding
clear message, the table size is limited by the
agent instrumentation.
The MIB supports two approaches for detecting
lost notifications:
- sequence numbers are used in the alarm
notifications, and are shown in the active
alarm table. The last used sequence number can
be read in a scalar variable
- a time stamp indicates the last time alarm
tables where updated.
Heartbeat mechanisms are supported both in pull
and push mode:
- Pull: the classical SNMP polling where a
manager polls a scalar variable, for example
the last sequence number used
- Push: the agent can be configured to send
heartbeat notifications. These contains the
last used sequence numbers.
Document number: 5/196 03-CXC 172 7549, Rev A"
REVISION "200810170000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { ericssonModules 4 }
--==========
--==Groups==
--==========
eriAlarmObjects OBJECT IDENTIFIER ::= { ericssonAlarmMIB 1 }
eriAlarmNotifications OBJECT IDENTIFIER ::= { ericssonAlarmMIB 2 }
eriAlarmNotifsPrefix OBJECT IDENTIFIER ::= { eriAlarmNotifications 0 }
eriAlarmConformance OBJECT IDENTIFIER ::= { ericssonAlarmMIB 4 }
eriAlarmSummary OBJECT IDENTIFIER ::= { eriAlarmObjects 1 } -- eriAlarmSum
eriAlarmNotifObjects OBJECT IDENTIFIER ::= { eriAlarmObjects 2 } -- eriAlarmNObj
eriAlarmActiveAlarms OBJECT IDENTIFIER ::= { eriAlarmObjects 3 } -- eriAlarmActive
eriAlarmAlerts OBJECT IDENTIFIER ::= { eriAlarmObjects 4 } -- eriAlarmAlert
eriAlarmHeartBeat OBJECT IDENTIFIER ::= { eriAlarmObjects 5 } -- eriAlarmHb
--====================
--==Alarm summary==
--====================
eriAlarmSumIndeterminate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the number of currently active
alarms with perceived severity 'indeterminate'.
Note that only stateful alarms are included."
::= { eriAlarmSummary 1 }
eriAlarmSumCritical OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the number of currently active
alarms with perceived severity 'critical'. Note
that only stateful alarms are included."
::= { eriAlarmSummary 2 }
eriAlarmSumMajor OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the number of currently active
alarms with perceived severity 'major'. Note
that only stateful alarms are included."
::= { eriAlarmSummary 3 }
eriAlarmSumMinor OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the number of currently active
alarms with perceived severity 'minor'. Note
that only stateful alarms are included."
::= { eriAlarmSummary 4 }
eriAlarmSumWarning OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the number of currently active
alarms with perceived severity 'warning'. Note
that only stateful alarms are included."
::= { eriAlarmSummary 5 }
--=============================
-- Notification objects
--==============================
eriAlarmNObjAdditionalText OBJECT-TYPE
SYNTAX EriAdditionalText
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This is a scalar variable only used in
notifications. It is size ranged with a smaller
size than the corresponding type used in the
active alarm table. This is in order to make sure
that all alarm information will fit into one UDP
packet. The additional text can be further
appended by using the dedicated append
notification."
::= { eriAlarmNotifObjects 1 }
eriAlarmNObjMoreAdditionalText OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This is a scalar variable only used in
notifications. It tells the management system
that the additional text will be appended by
subsequent append additional text notifications.
NOTE: this object exists simply because of the
limitations of PDU size inherent in SNMP over
UDP, which limits the size of the PDU+headers to
under 1500 octets. Otherwise, the notification
will be fragmented."
::= { eriAlarmNotifObjects 2 }
eriAlarmNObjResourceId OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This is a scalar variable only used in
notifications. It tells the management system
that there is an SNMP-based Resource ID (OID)
that identifies the alarming resource. NOTE:
this object exists simply because of the
limitations of PDU size inherent in SNMP over
UDP, which limits the size of the PDU+headers to
under 1500 octets. Otherwise, the notification
will be fragmented."
::= { eriAlarmNotifObjects 3 }
--======================
--==Active Alarm table==
--======================
eriAlarmActiveNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the total number of currently
active alarms, i.e. the total number of entries
in the Alarm Table."
::= { eriAlarmActiveAlarms 1 }
eriAlarmActiveLastChanged OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A timestamp when the active alarm table was last
changed. The value can be used by a manager to
initiate an alarm resynchronization procedure.
NOTE: All fields of the DateAndTime MUST be
filled out, including the hours and minutes from
UTC. As such, the value should be 11 octets
long."
REFERENCE
"DateAndTime is defined in RFC 2579, page 18"
::= { eriAlarmActiveAlarms 2 }
eriAlarmActiveLastSequenceNo OBJECT-TYPE
SYNTAX EriAlarmSequenceNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last used sequence number for a alarm state
change notification. A management system can poll
this variable in order to detect lost alarm
change notifications."
::= { eriAlarmActiveAlarms 3 }
eriAlarmActiveTableURL OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A URL pointing to a location where the contents
of the alarm table can be retrieved as a file.
The actual format of the file is out of the scope
of this MIB and can be found in the system
documentation. A Uniform Resource Locator in
accordance with RFC 4248. A string of length
zero means that the agent does not have a URL to
provide."
::= { eriAlarmActiveAlarms 4 }
eriAlarmActiveAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF EriAlarmActiveAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table list all active alarms in the system.
The aspect is the resource view of the alarms,
not the administrative states and processes
performed by users. The number of entries,
active alarms, can be read in
eriAlarmActiveNumber. Entries are created when a
resource has a new alarm state. If the same
resource has several active alarms, with
different Alarm Types, this will be represented
as separate rows. Rows disappear whenever the
alarm is cleared in the resource.
Rows can be changed when an alarm changes
severity or additional text. Alarms where the
clear state cannot be detected by the resource
are not represented in this table.
The contents of the active alarm table can also
be fetched using file transfer.
eriAlarmActiveTableURL provides a URL to the
file."
::= { eriAlarmActiveAlarms 5 }
eriAlarmActiveAlarmEntry OBJECT-TYPE
SYNTAX EriAlarmActiveAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"One entry in the table holds one active alarm
for a given resource. Entries are created by the
system when a resource has a new alarm state.
Entries are deleted by the system when a resource
alarm state is cleared.
Alarm severity and additional text can later be
changed in a row."
INDEX {
eriAlarmActiveIndex
}
::= { eriAlarmActiveAlarmTable 1 }
EriAlarmActiveAlarmEntry ::= SEQUENCE {
eriAlarmActiveIndex EriAlarmIndex,
eriAlarmActiveMajorType EriAlarmType, -- Unique integer
eriAlarmActiveMinorType EriAlarmType, -- Unique integer
eriAlarmActiveSpecificProblem EriAlarmSpecificProblem, -- Unique text
eriAlarmActiveManagedObject EriMO, -- Distinguished Name
eriAlarmActiveEventType IANAItuEventType, -- X.733
eriAlarmActiveEventTime DateAndTime, -- Time for last state change
eriAlarmActiveOriginalEventTime DateAndTime, -- Time for alarm raise
eriAlarmActiveProbableCause EriProbableCause, -- X.733
eriAlarmActiveSeverity ItuPerceivedSeverity, -- Last state change
eriAlarmActiveOriginalSeverity ItuPerceivedSeverity, -- Alarm raise
eriAlarmActiveAdditionalText EriLargeAdditionalText, -- Last state change
eriAlarmActiveOrigAdditionalText EriLargeAdditionalText, -- Alarm raise
eriAlarmActiveResourceId ResourceId -- SNMP OID for MO
}
eriAlarmActiveIndex OBJECT-TYPE
SYNTAX EriAlarmIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each
alarm. It is recommended that values are
assigned contiguously starting from 1. The value
for each alarm must remain constant at least from
one re-initialization of the entity to the next
re-initialization. Note that this index should
not be used for alarm synchronization purposes
since the 'logical' index for an alarm is
- eriAlarmActiveMajorType
- eriAlarmActiveMinorType
- eriAlarmActiveManagedObject"
::= { eriAlarmActiveAlarmEntry 1 }
eriAlarmActiveMajorType OBJECT-TYPE
SYNTAX EriAlarmType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In combination with eriAlarmActiveMinorType,
this provides a unique identification of the
fault type. Different managed object types and
instances can share alarm types, but if the same
managed object reports the same alarm type, it is
to be considered as the same alarm state. The
alarm type is a simplification of the different
X.733 and 3GPP alarm IRP alarm correlation
mechanisms based on EventType, ProbableCause,
SpecificProblem and NotificationId. For systems
where eriAlarmActiveMajorType is not needed for
identification purposes, it is not used and MUST
be zero-valued."
::= { eriAlarmActiveAlarmEntry 2 }
eriAlarmActiveMinorType OBJECT-TYPE
SYNTAX EriAlarmType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In combination with with
eriAlarmActiveMajorType, this provides a unique
identification of the fault type, not including
the managed object. Different managed object
types and instances can share alarm types, but if
the same managed object reports the same alarm
type it is to be considered as the same alarm
state. The alarm type is a simplification of the
different X.733 and 3GPP alarm IRP alarm
correlation mechanisms based on EventType,
ProbableCause, SpecificProblem and
NotificationId."
::= { eriAlarmActiveAlarmEntry 3 }
eriAlarmActiveSpecificProblem OBJECT-TYPE
SYNTAX EriAlarmSpecificProblem
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a clear-text unique identification of
the alarm type. There is a one-to-one mapping
between eriAlarmActiveSpecificProblem and
[eriAlarmActiveMajorType,eriAlarmActiveMinorType]"
::= { eriAlarmActiveAlarmEntry 4 }
eriAlarmActiveManagedObject OBJECT-TYPE
SYNTAX EriMO
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 3GPP naming convention shall be used as
format for the managed object parameter. Note
that the granularity must be good enough to
guarantee unique alarm states and relevant
resource identification to the operator.
NOTE: The DN should be *relative* to the nodes
*own* root."
REFERENCE
"3GPP TS 32.106-8 V3.2, Name convention for
Managed Objects"
::= { eriAlarmActiveAlarmEntry 5 }
eriAlarmActiveEventType OBJECT-TYPE
SYNTAX IANAItuEventType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The event type as defined in X.733/X.736."
REFERENCE
"ITU Recommendation X.733, 'Information
Technology - Open Systems Interconnection -
System Management: Alarm Reporting Function',
1992"
::= { eriAlarmActiveAlarmEntry 6 }
eriAlarmActiveEventTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A time stamp of the alarm state change event.
Note that this variable represents the last
change of the alarm state, like changed severity
or additional text. If the alarm has not changed
state this variable represents the alarm raise
time and will be the same as originalEventTime.
NOTE: All fields of the DateAndTime MUST be
filled out, including the hours and minutes from
UTC. As such, the value should be 11 octets
long."
REFERENCE
"DateAndTime is defined in RFC 2579, page 18.
ITU Recommendation X.733, 'Information Technology
- Open Systems Interconnection - System
Management: Alarm Reporting Function', 1992"
::= { eriAlarmActiveAlarmEntry 7 }
eriAlarmActiveOriginalEventTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time-stamp of the original alarm raise
notification.
NOTE: All fields of the DateAndTime MUST be
filled out, including the hours and minutes from
UTC. As such, the value should be 11 octets
long."
REFERENCE
"DateAndTime is defined in RFC 2579, page 18."
::= { eriAlarmActiveAlarmEntry 8 }
eriAlarmActiveProbableCause OBJECT-TYPE
SYNTAX EriProbableCause
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The probable cause for the alarm originally
defined by X.733 and subsequent standards. See
also the ERICSSON-ALARM-PC-MIB. Due to the
history of problems in maintaining a standardized
probable cause the probable cause is not unique.
A best effort mapping of the alarm to existing
probable causes are used."
REFERENCE
"ITU Recommendation X.733, 'Information
Technology - Open Systems Interconnection -
System Management: Alarm Reporting Function',
1992"
::= { eriAlarmActiveAlarmEntry 9 }
eriAlarmActiveSeverity OBJECT-TYPE
SYNTAX ItuPerceivedSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm as defined by X.733.
Note that this may not be the original severity
since the alarm may have changed severity."
REFERENCE
"ITU Recommendation X.733, 'Information
Technology - Open Systems Interconnection -
System Management: Alarm Reporting Function',
1992"
::= { eriAlarmActiveAlarmEntry 10 }
eriAlarmActiveOriginalSeverity OBJECT-TYPE
SYNTAX ItuPerceivedSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The original severity as reported by the alarm
raise notification."
::= { eriAlarmActiveAlarmEntry 11 }
eriAlarmActiveAdditionalText OBJECT-TYPE
SYNTAX EriLargeAdditionalText
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user friendly text describing the alarm. The
text is both static depending on the alarm type
(probable cause), and dynamic depending on
managed object instance and other conditions.
This string is longer than the corresponding
varbind in the notification in order to manage
large strings."
REFERENCE
"ITU Recommendation X.733, 'Information
Technology - Open Systems Interconnection -
System Management: Alarm Reporting Function',
1992"
::= { eriAlarmActiveAlarmEntry 12 }
eriAlarmActiveOrigAdditionalText OBJECT-TYPE
SYNTAX EriLargeAdditionalText
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user-friendly text describing the alarm. The
text is both static depending on the alarm type
(probable cause), and dynamic depending on
managed object and other conditions. This is the
original text as reported by the first alarm
notification, after which it is not altered."
REFERENCE
"ITU Recommendation X.733, 'Information
Technology - Open Systems Interconnection -
System Management: Alarm Reporting Function',
1992"
::= { eriAlarmActiveAlarmEntry 13 }
eriAlarmActiveResourceId OBJECT-TYPE
SYNTAX ResourceId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In case the alarm refers to an object which is
instrumented by SNMP this variable indicates the
corresponding OID for the managed object."
REFERENCE
"RFC 3877 IETF ALARM MIB"
::= { eriAlarmActiveAlarmEntry 14 }
--======================
--==Alert table==
--======================
-- This table lists the latest reported alerts.
eriAlarmAlertNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of rows in the alert table."
::= { eriAlarmAlerts 1 }
eriAlarmAlertLastChanged OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A timestamp when the alert table was last
changed. Can be used by a manager to initiate a
an update of alerts procedure.
NOTE: All fields of the DateAndTime MUST be
filled out, including the hours and minutes from
UTC. As such, the value should be 11 octets
long."
REFERENCE
"DateAndTime is defined in RFC 2579, page 18"
::= { eriAlarmAlerts 2 }
eriAlarmAlertLastSequenceNo OBJECT-TYPE
SYNTAX EriAlarmSequenceNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last sequence number used in alert
notifications. This can be used to detect a lost
notification."
::= { eriAlarmAlerts 3 }
eriAlarmAlertTableURL OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A URL pointing to a location where the contents
of alert table can be retrieved as a file. The
format of the file is out of the scope of this
MIB and system dependant. A Uniform Resource
Locator in accordance with RFC 4248."
::= { eriAlarmAlerts 4 }
eriAlarmAlertTable OBJECT-TYPE
SYNTAX SEQUENCE OF EriAlarmAlertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the last alerts in the system.
An alert is a stateless alarm, that is no clear
notification will be sent. Rows in this table are
created when a new alarm event is detected. Rows
are deleted by the instrumentation at a
predefined size or age."
::= { eriAlarmAlerts 5 }
eriAlarmAlertEntry OBJECT-TYPE
SYNTAX EriAlarmAlertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"One entry in the table holds one alert for a
given resource. Rows in this table are created
when a new alert is detected. Rows are deleted
by the instrumentation at a predefined size or
age."
INDEX { eriAlarmAlertIndex }
::= { eriAlarmAlertTable 1 }
EriAlarmAlertEntry ::= SEQUENCE {
eriAlarmAlertIndex EriAlarmIndex,
eriAlarmAlertMajorType EriAlarmType,
eriAlarmAlertMinorType EriAlarmType,
eriAlarmAlertSpecificProblem EriAlarmSpecificProblem,
eriAlarmAlertManagedObject EriMO,
eriAlarmAlertEventType IANAItuEventType,
eriAlarmAlertEventTime DateAndTime,
eriAlarmAlertProbableCause EriProbableCause,
eriAlarmAlertSeverity ItuPerceivedSeverity,
eriAlarmAlertAdditionalText EriLargeAdditionalText,
eriAlarmAlertResourceId ResourceId
}
eriAlarmAlertIndex OBJECT-TYPE
SYNTAX EriAlarmIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index in the alert table."
::= { eriAlarmAlertEntry 1 }
eriAlarmAlertMajorType OBJECT-TYPE
SYNTAX EriAlarmType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In combination with eriAlarmAlertMinorType, this
provides unique identification of the fault.
Different managed object types and instances can
share alarm types, but if the same managed object
reports the same alarm type it is to be
considered as the same alarm state. The alarm
type is a simplification of the different X.733
and 3GPP alarm IRP alarm correlation mechanisms
based on EventType, ProbableCause,
SpecificProblem and NotificationId."
::= { eriAlarmAlertEntry 2 }
eriAlarmAlertMinorType OBJECT-TYPE
SYNTAX EriAlarmType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In combination with eriAlarmAlertMajorType, this
provides a unique identification of the fault.
Different managed object types and instances can
share alarm types. But if the same managed object
reports the same alarm type it is to be
considered as the same alarm state. The alarm
type is a simplification of the different X.733
and 3GPP alarm IRP alarm correlation mechanisms
based on EventType, ProbableCause,
SpecificProblem and NotificationId. "
::= { eriAlarmAlertEntry 3 }
eriAlarmAlertSpecificProblem OBJECT-TYPE
SYNTAX EriAlarmSpecificProblem
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a clear-text unique identification of
the alert type. There is a one-to-one mapping
between eriAlarmAlertSpecificProblem and
[eriAlarmAlertMajorType, eriAlarmAlertMinorType]"
::= { eriAlarmAlertEntry 4 }
eriAlarmAlertManagedObject OBJECT-TYPE
SYNTAX EriMO
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 3GPP naming convention shall be used as
format for the managed object parameter. Note
that the granularity must be good enough to
guarantee relevant resource identification to the
operator.
NOTE: The DN should be *relative* to the nodes
*own* root."
REFERENCE
"3GPP TS 32.106-8 V3.2, Name convention for
Managed Objects"
::= { eriAlarmAlertEntry 5 }
eriAlarmAlertEventType OBJECT-TYPE
SYNTAX IANAItuEventType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The event type as defined in X.733/X.736."
REFERENCE
"ITU Recommendation X.733, 'Information
Technology - Open Systems Interconnection -
System Management: Alarm Reporting Function',
1992"
::= { eriAlarmAlertEntry 6 }
eriAlarmAlertEventTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A time stamp of the alert. NOTE: All fields of
the DateAndTime MUST be filled out, including the
hours and minutes from UTC. As such, the value
should be 11 octets long."
REFERENCE
"DateAndTime is defined in RFC 2579, page 18.
ITU Recommendation X.733, 'Information Technology
- Open Systems Interconnection - System
Management: Alarm Reporting Function', 1992"
::= { eriAlarmAlertEntry 7 }
eriAlarmAlertProbableCause OBJECT-TYPE
SYNTAX EriProbableCause
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The probable cause for the alarm originally
defined by X.733 and subsequent standards.
See also the ERICSSON-ALARM-PC-MIB. Due to the
history of problems in maintaining a standardized
probable cause the probable cause is not unique.
A best effort mapping of the alert to existing
probable causes are used."
REFERENCE
"ITU Recommendation X.733, 'Information
Technology - Open Systems Interconnection -
System Management: Alarm Reporting Function',
1992"
::= { eriAlarmAlertEntry 8 }
eriAlarmAlertSeverity OBJECT-TYPE
SYNTAX ItuPerceivedSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alert as defined by X.733"
REFERENCE
"ITU Recommendation X.733, 'Information
Technology - Open Systems Interconnection -
System Management: Alarm Reporting Function',
1992"
::= { eriAlarmAlertEntry 9 }
eriAlarmAlertAdditionalText OBJECT-TYPE
SYNTAX EriLargeAdditionalText
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user friendly text describing the alert. The
text is both static depending on the alert type
and dynamic depending on managed object and other
conditions."
REFERENCE
"ITU Recommendation X.733, 'Information
Technology - Open Systems Interconnection -
System Management: Alarm Reporting Function',
1992"
::= { eriAlarmAlertEntry 10 }
eriAlarmAlertResourceId OBJECT-TYPE
SYNTAX ResourceId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In case the alert refers to an object which is
instrumented by SNMP this variable indicates the
corresponding OID for the managed object."
REFERENCE
"RFC 3877 IETF ALARM MIB"
::= { eriAlarmAlertEntry 11 }
--=============
-- Heartbeat
--==============
eriAlarmHbInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The notification eriAlarmHeartBeatNotif will be
sent every eriAlarmHbInterval. Managers can
subscribe to the notification using the SNMP
framework MIBS by using the snmpNotifyName
'heartbeat'. (SNMP-NOTIFICATION-MIB,
snmpNotifyTable)"
::= { eriAlarmHeartBeat 1 }
--====================================================
--==Notifications and notification specific objects ==
--====================================================
eriAlarmIndeterminate NOTIFICATION-TYPE
OBJECTS {
eriAlarmActiveManagedObject,
eriAlarmActiveMajorType,
eriAlarmActiveMinorType,
eriAlarmActiveSpecificProblem,
eriAlarmActiveLastSequenceNo,
eriAlarmActiveEventType,
eriAlarmActiveEventTime,
eriAlarmActiveProbableCause,
eriAlarmNObjAdditionalText,
eriAlarmNObjMoreAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"This notification is sent when a resource
detects a new alarm state with severity
indeterminate. The notification is also used to
change severity and/or additional text of an
alarm. The combination of ManagedObject and
MajorType/MinorType is always unique and can be
used by management systems to correlate alarm,
alarm change, and alarm clear. A corresponding
row will be created in the Alarm Table. The
sequence number will increase for every
notification and can be used to detect lost
notifications.
A management system should be prepared for
appending text to additional text, indicated by
the eriAlarmNObjMoreAdditionalText varbind, and
sent with eriAlarmAppendInfo. (Note do not
confuse this with a change of additional text.)
A management system should also be prepared to
receive a resource ID (OID) identifying the
alarming resource if the system sending the
notification can provide that information. In
that case, eriAlarmNObjResourceId will be set to
'true' and the resource ID will be sent in an
eriAlarmAppendInfo notification."
::= { eriAlarmNotifsPrefix 1 }
eriAlarmWarning NOTIFICATION-TYPE
OBJECTS {
eriAlarmActiveManagedObject,
eriAlarmActiveMajorType,
eriAlarmActiveMinorType,
eriAlarmActiveSpecificProblem,
eriAlarmActiveLastSequenceNo,
eriAlarmActiveEventType,
eriAlarmActiveEventTime,
eriAlarmActiveProbableCause,
eriAlarmNObjAdditionalText,
eriAlarmNObjMoreAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"This notification is sent when a resource
detects a new alarm state with severity warning.
The notification is also used to change severity
and/or additional text of an alarm. The
combination of ManagedObject and
MajorType/MinorType is always unique and can be
used by management systems to correlate alarm,
alarm change, and alarm clear. A corresponding
row will be created in the Alarm Table,
(eriAlarmActiveAlarmTable). The sequence number
will increase for every notification and can be
used to detect lost notifications.
A management system should be prepared for
appending text to additional text, indicated by
the eriAlarmNObjMoreAdditionalText varbind, and
sent with eriAlarmAppendInfo. (Note do not
confuse this with a change of additional text.)
A management system should also be prepared to
receive a resource ID (OID) identifying the
alarming resource if the system sending the
notification can provide that information. In
that case, eriAlarmNObjResourceId will be set to
'true' and the resource ID will be sent in an
eriAlarmAppendInfo notification."
::= { eriAlarmNotifsPrefix 2 }
eriAlarmMinor NOTIFICATION-TYPE
OBJECTS {
eriAlarmActiveManagedObject,
eriAlarmActiveMajorType,
eriAlarmActiveMinorType,
eriAlarmActiveSpecificProblem,
eriAlarmActiveLastSequenceNo,
eriAlarmActiveEventType,
eriAlarmActiveEventTime,
eriAlarmActiveProbableCause,
eriAlarmNObjAdditionalText,
eriAlarmNObjMoreAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"This notification is sent when a resource
detects a new alarm state with severity minor.
The notification is also used to change severity
and/or additional text of an alarm. The
combination of ManagedObject and
MajorType/MinorType is always unique and can be
used by management systems to correlate alarm,
alarm change, and alarm clear. A corresponding
row will be created in the Alarm Table,
(eriAlarmActiveAlarmTable). The sequence number
will increase for every notification and can be
used to detect lost notifications.
A management system should be prepared for
appending text to additional text, indicated by
the eriAlarmNObjMoreAdditionalText varbind, and
sent with eriAlarmAppendInfo. (Note do not
confuse this with a change of additional text.)
A management system should also be prepared to
receive a resource ID (OID) identifying the
alarming resource if the system sending the
notification can provide that information. In
that case, eriAlarmNObjResourceId will be set to
'true' and the resource ID will be sent in an
eriAlarmAppendInfo notification."
::= { eriAlarmNotifsPrefix 3 }
eriAlarmMajor NOTIFICATION-TYPE
OBJECTS {
eriAlarmActiveManagedObject,
eriAlarmActiveMajorType,
eriAlarmActiveMinorType,
eriAlarmActiveSpecificProblem,
eriAlarmActiveLastSequenceNo,
eriAlarmActiveEventType,
eriAlarmActiveEventTime,
eriAlarmActiveProbableCause,
eriAlarmNObjAdditionalText,
eriAlarmNObjMoreAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"This notification is sent when a resource
detects a new alarm state with severity major.
The notification is also used to change severity
and/or additional text of an alarm. The
combination of ManagedObject and
MajorType/MinorType is always unique and can be
used by management systems to correlate alarm,
alarm change, and alarm clear. A corresponding
row will be created in the Alarm Table,
(eriAlarmActiveAlarmTable). The sequence number
will increase for every notification and can be
used to detect lost notifications.
A management system should be prepared for
appending text to additional text, indicated by
the eriAlarmNObjMoreAdditionalText varbind, and
sent with eriAlarmAppendInfo. (Note do not
confuse this with a change of additional text.)
A management system should also be prepared to
receive a resource ID (OID) identifying the
alarming resource if the system sending the
notification can provide that information. In
that case, eriAlarmNObjResourceId will be set to
'true' and the resource ID will be sent in an
eriAlarmAppendInfo notification."
::= { eriAlarmNotifsPrefix 4 }
eriAlarmCritical NOTIFICATION-TYPE
OBJECTS {
eriAlarmActiveManagedObject,
eriAlarmActiveMajorType,
eriAlarmActiveMinorType,
eriAlarmActiveSpecificProblem,
eriAlarmActiveLastSequenceNo,
eriAlarmActiveEventType,
eriAlarmActiveEventTime,
eriAlarmActiveProbableCause,
eriAlarmNObjAdditionalText,
eriAlarmNObjMoreAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"This notification is sent when a resource
detects a new alarm state with severity critical.
The notification is also used to change severity
and/or additional text of an alarm. The
combination of ManagedObject and
MajorType/MinorType is always unique and can be
used by management systems to correlate alarm,
alarm change, and alarm clear. A corresponding
row will be created in the Alarm Table,
(eriAlarmActiveAlarmTable). The sequence number
will increase for every notification and can be
used to detect lost notifications.
A management system should be prepared for
appending text to additional text, indicated by
the eriAlarmNObjMoreAdditionalText varbind, and
sent with eriAlarmAppendInfo. (Note do not
confuse this with a change of additional text.)
A management system should also be prepared to
receive a resource ID (OID) identifying the
alarming resource if the system sending the
notification can provide that information. In
that case, eriAlarmNObjResourceId will be set to
'true' and the resource ID will be sent in an
eriAlarmAppendInfo notification."
::= { eriAlarmNotifsPrefix 5 }
eriAlarmCleared NOTIFICATION-TYPE
OBJECTS {
eriAlarmActiveManagedObject,
eriAlarmActiveMajorType,
eriAlarmActiveMinorType,
eriAlarmActiveSpecificProblem,
eriAlarmActiveLastSequenceNo,
eriAlarmActiveEventType,
eriAlarmActiveEventTime,
eriAlarmActiveProbableCause,
eriAlarmNObjAdditionalText,
eriAlarmNObjMoreAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"This notification is sent when a resource
detects a cleared alarm state. The combination
of ManagedObject and MajorType/MinorType is
always unique and shall be used by management
systems to correlate alarm and alarm clear. The
corresponding row in the alarm table will be
deleted, (eriAlarmActiveAlarmTable). The
sequence number will increase for every
notification and can be used to detect lost
notifications. A management system should be
prepared for appending text to additional text,
indicated by the eriAlarmNObjMoreAdditionalText
varbind, and sent with eriAlarmAppendInfo.
(Note do not confuse this with a change of
additional text).
A management system should also be prepared to
receive a resource ID (OID) identifying the
alarming resource if the system sending the
notification can provide that information. In
that case, eriAlarmNObjResourceId will be set to
'true' and the resource ID will be sent in an
eriAlarmAppendInfo notification.
A management system should also be prepared to
receive a resource ID (OID) identifying the
alarming resource if the system sending the
notification can provide that information. In
that case, eriAlarmNObjResourceId will be set to
'true' and the resource ID will be sent in an
eriAlarmAppendInfo notification."
::= { eriAlarmNotifsPrefix 7 }
eriAlarmAppendInfo NOTIFICATION-TYPE
OBJECTS {
eriAlarmActiveManagedObject,
eriAlarmActiveMajorType,
eriAlarmActiveMinorType,
eriAlarmNObjAdditionalText,
eriAlarmActiveResourceId
}
STATUS current
DESCRIPTION
"This notification is sent in order to append
further info to an existing alarm. It might be
additional text or a resource ID (OID)
identifying the alarming resource using an OID.
If additional text is sent, do not confuse this
with an actual change of additional text which is
reported using the eriAlarm<severity>
notification.
A zero-length string value for
eriAlarmNObjAdditionalText means that no
additional text is being sent in this
notification.
A null OID (0.0) value for
eriAlarmActiveResourceId means that no resource
ID is being sent in this notification."
::= { eriAlarmNotifsPrefix 8 }
--============================
-- Alerts
--===============================
eriAlarmIndAlert NOTIFICATION-TYPE
OBJECTS {
eriAlarmAlertManagedObject,
eriAlarmAlertMajorType,
eriAlarmAlertMinorType,
eriAlarmAlertSpecificProblem,
eriAlarmAlertLastSequenceNo,
eriAlarmAlertEventType,
eriAlarmAlertEventTime,
eriAlarmAlertProbableCause,
eriAlarmNObjAdditionalText,
eriAlarmNObjMoreAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"This notification is sent when a resource
detects a new alert with severity indeterminate.
A corresponding row will be created in the Alert
Table. The sequence number will increase for
every notification and can be used to detect lost
notifications."
::= { eriAlarmNotifsPrefix 10 }
eriAlarmWarnAlert NOTIFICATION-TYPE
OBJECTS {
eriAlarmAlertManagedObject,
eriAlarmAlertMajorType,
eriAlarmAlertMinorType,
eriAlarmAlertSpecificProblem,
eriAlarmAlertLastSequenceNo,
eriAlarmAlertEventType,
eriAlarmAlertEventTime,
eriAlarmAlertProbableCause,
eriAlarmNObjAdditionalText,
eriAlarmNObjMoreAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"This notification is sent when a resource
detects a new alert with severity warning. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
every notification and can be used to detect lost
notifications."
::= { eriAlarmNotifsPrefix 11 }
eriAlarmMinorAlert NOTIFICATION-TYPE
OBJECTS {
eriAlarmAlertManagedObject,
eriAlarmAlertMajorType,
eriAlarmAlertMinorType,
eriAlarmAlertSpecificProblem,
eriAlarmAlertLastSequenceNo,
eriAlarmAlertEventType,
eriAlarmAlertEventTime,
eriAlarmAlertProbableCause,
eriAlarmNObjAdditionalText,
eriAlarmNObjMoreAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"This notification is sent when a resource
detects a new alert with severity minor. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
every notification and can be used to detect lost
notifications."
::= { eriAlarmNotifsPrefix 12 }
eriAlarmMajorAlert NOTIFICATION-TYPE
OBJECTS {
eriAlarmAlertManagedObject,
eriAlarmAlertMajorType,
eriAlarmAlertMinorType,
eriAlarmAlertSpecificProblem,
eriAlarmAlertLastSequenceNo,
eriAlarmAlertEventType,
eriAlarmAlertEventTime,
eriAlarmAlertProbableCause,
eriAlarmNObjAdditionalText,
eriAlarmNObjMoreAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"This notification is sent when a resource
detects a new alert with severity major. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
every notification and can be used to detect lost
notifications."
::= { eriAlarmNotifsPrefix 13 }
eriAlarmCriticalAlert NOTIFICATION-TYPE
OBJECTS {
eriAlarmAlertManagedObject,
eriAlarmAlertMajorType,
eriAlarmAlertMinorType,
eriAlarmAlertSpecificProblem,
eriAlarmAlertLastSequenceNo,
eriAlarmAlertEventType,
eriAlarmAlertEventTime,
eriAlarmAlertProbableCause,
eriAlarmNObjAdditionalText,
eriAlarmNObjMoreAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"This notification is sent when a resource
detects a new alert with severity critical. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
every notification and can be used to detect lost
notifications."
::= { eriAlarmNotifsPrefix 14 }
eriAlarmAppendAlertInfo NOTIFICATION-TYPE
OBJECTS {
eriAlarmAlertManagedObject,
eriAlarmAlertMajorType,
eriAlarmAlertMinorType,
eriAlarmNObjAdditionalText,
eriAlarmAlertResourceId
}
STATUS current
DESCRIPTION
"This notification is sent in order to append
further info to an existing alert. It might be
additional text or a resource ID (OID)
identifying the alarming resource using an OID.
This complements information sent in a previous
notification.
If additional text is sent, do not confuse this
with an actual change of additional text which is
reported using the eriAlarmAlert<severity>
notification.
A zero-length string value for
eriAlarmNObjAdditionalText means that no
additional text is being sent in this
notification.
A null OID (0.0) value for
eriAlarmAlertResourceId means that no resource
ID is being sent in this notification."
::= { eriAlarmNotifsPrefix 15 }
eriAlarmHeartBeatNotif NOTIFICATION-TYPE
OBJECTS {
eriAlarmActiveLastSequenceNo,
eriAlarmAlertLastSequenceNo,
eriAlarmActiveLastChanged,
eriAlarmAlertLastChanged
}
STATUS current
DESCRIPTION
"This is a heartbeat notification with interval
according to the eriAlarmHbInterval. It contains
the last sequence numbers used for alarms and
alarm events. These varbinds can be used to
detect lost notifications.
The notification eriAlarmHeartBeatNotif will be
sent every eriAlarmHbInterval. Managers can
subscribe to the notification using the SNMP
framework MIBS by using the snmpNotifyName
'heartbeat'. (SNMP-NOTIFICATION-MIB,
snmpNotifyTable)."
::= { eriAlarmNotifsPrefix 20}
eriAlarmAlarmListRebuilt NOTIFICATION-TYPE
OBJECTS { eriAlarmActiveTableURL }
STATUS current
DESCRIPTION
"This notification is sent when the active alarm
list has reached a stable situation after a
restart or after a system internal audit process.
It is an indication to the manager to perform a
alarm resynchronization procedure."
::= { eriAlarmNotifsPrefix 30}
--======================================================================
-- CONFORMANCE INFORMATION
--======================================================================
eriAlarmCompliances OBJECT IDENTIFIER ::= { eriAlarmConformance 1 }
eriAlarmBasicAlarmsCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Minimal compliance for the Ericsson Alarm MIB.
Minimal compliance is to support heartbeat,
active alarm list, and alarm notifications for
raise and clear."
MODULE -- this module
MANDATORY-GROUPS
{
eriAlarmSummaryGroup,
eriAlarmActiveAlarmsGroup,
eriAlarmHeartBeatGroup,
eriAlarmSimpleAlarmGroup,
eriAlarmHeartBeatNotifGroup
}
GROUP eriAlarmAlertsGroup
DESCRIPTION "If the system supports history of
stateless events, alerts."
GROUP eriAlarmAlertNotifGroup
DESCRIPTION "If the system supports notifications
for stateless events, alerts."
GROUP eriAlarmChangeAlarmGroup
DESCRIPTION "If the system supports columns in
the alarm table for original attribute values of
additional text, severity and event time."
GROUP eriAlarmAddAddInfoGroup
DESCRIPTION "If the system supports notifications
to append text or resource id to existing alarms."
GROUP eriAlarmSNMPResourceGroup
DESCRIPTION "If the system supports SNMP Object
Identifiers to identify managed objects in
parallel with DNs."
OBJECT eriAlarmHbInterval
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, but is highly
desirable."
MODULE SNMP-TARGET-MIB
MANDATORY-GROUPS {snmpTargetBasicGroup}
MODULE SNMP-NOTIFICATION-MIB
MANDATORY-GROUPS {snmpNotifyGroup}
::= {eriAlarmCompliances 1}
eriAlarmGroups OBJECT IDENTIFIER ::= { eriAlarmConformance 2 }
eriAlarmSummaryGroup OBJECT-GROUP
OBJECTS {
eriAlarmSumIndeterminate,
eriAlarmSumCritical,
eriAlarmSumMajor,
eriAlarmSumMinor,
eriAlarmSumWarning
}
STATUS current
DESCRIPTION
"Group containing the summary counters for alarms."
::= { eriAlarmGroups 1 }
eriAlarmActiveAlarmsGroup OBJECT-GROUP
OBJECTS {
eriAlarmActiveNumber,
eriAlarmActiveLastChanged,
eriAlarmActiveLastSequenceNo,
eriAlarmActiveTableURL,
eriAlarmActiveMajorType,
eriAlarmActiveMinorType,
eriAlarmActiveSpecificProblem,
eriAlarmActiveManagedObject,
eriAlarmActiveEventType,
eriAlarmActiveEventTime,
eriAlarmActiveProbableCause,
eriAlarmActiveSeverity,
eriAlarmActiveAdditionalText,
eriAlarmNObjAdditionalText,
eriAlarmNObjResourceId
}
STATUS current
DESCRIPTION
"The group of objects needed to support the
active alarm list."
::= { eriAlarmGroups 2 }
eriAlarmAlertsGroup OBJECT-GROUP
OBJECTS {
eriAlarmAlertNumber,
eriAlarmAlertLastChanged,
eriAlarmAlertLastSequenceNo,
eriAlarmAlertTableURL,
eriAlarmAlertMajorType,
eriAlarmAlertMinorType,
eriAlarmAlertSpecificProblem,
eriAlarmAlertManagedObject,
eriAlarmAlertEventType,
eriAlarmAlertEventTime,
eriAlarmAlertProbableCause,
eriAlarmAlertSeverity,
eriAlarmAlertAdditionalText
}
STATUS current
DESCRIPTION
"The group of objects needed to support the alert
history."
::= { eriAlarmGroups 3 }
eriAlarmHeartBeatGroup OBJECT-GROUP
OBJECTS {eriAlarmHbInterval}
STATUS current
DESCRIPTION
"Only read is required for compliance"
::= { eriAlarmGroups 4 }
eriAlarmSNMPResourceGroup OBJECT-GROUP
OBJECTS {
eriAlarmActiveResourceId,
eriAlarmAlertResourceId
}
STATUS current
DESCRIPTION
"Objects that support SNMP object identifiers for
resource identification."
::= { eriAlarmGroups 5 }
eriAlarmChangeAlarmGroup OBJECT-GROUP
OBJECTS {
eriAlarmActiveOriginalEventTime,
eriAlarmActiveOriginalSeverity,
eriAlarmActiveOrigAdditionalText,
eriAlarmNObjMoreAdditionalText
}
STATUS current
DESCRIPTION
"Objects that stores previous state of an alarm."
::= { eriAlarmGroups 6 }
eriAlarmSimpleAlarmGroup NOTIFICATION-GROUP
NOTIFICATIONS {
eriAlarmIndeterminate,
eriAlarmWarning,
eriAlarmMinor,
eriAlarmMajor,
eriAlarmCritical,
eriAlarmCleared,
eriAlarmAlarmListRebuilt
}
STATUS current
DESCRIPTION
"The notifications in this MIB module."
::= { eriAlarmGroups 10 }
eriAlarmAddAddInfoGroup NOTIFICATION-GROUP
NOTIFICATIONS {
eriAlarmAppendInfo,
eriAlarmAppendAlertInfo
}
STATUS current
DESCRIPTION
"Notification to support appending of additional text."
::= { eriAlarmGroups 12 }
eriAlarmAlertNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS {
eriAlarmIndAlert,
eriAlarmWarnAlert,
eriAlarmMinorAlert,
eriAlarmMajorAlert,
eriAlarmCriticalAlert
}
STATUS current
DESCRIPTION
"Notifications for stateless alarms"
::= { eriAlarmGroups 13 }
eriAlarmHeartBeatNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS {eriAlarmHeartBeatNotif}
STATUS current
DESCRIPTION
"Heartbeat notifications."
::= { eriAlarmGroups 14 }
--======================================================================
-- COMPLIANCE STATEMENTS
--======================================================================
END --this file