Observium_CE/mibs/electroline/ELECTROLINE-DHT-GLOBAL-FIBERNODE-MIB

953 lines
27 KiB
Plaintext

--**************************************************************************
--
-- Copyright 2012 Electroline Equipment Inc
-- All Rights Reserved
--
--
--
--**************************************************************************
-- Filename : ELECTROLINE-DHT-GLOBAL-FIBERNODE.mib
-- Author : Anass El bahri
-- Creation Date : 2012.10.26
--
--**************************************************************************
-- Description:
--
-- This MIB contains all Global Fiber Node Mibs extension
--
--**************************************************************************
-- Revision History:
-- 2012.10.26 Anass El bahri First Draft
-- 2012.12.05 Anass El bahri Add the control MIBS
-- 2012.12.17 Anass El bahri Add comment (official version)
-- 2013.04.29 Anass El bahri Add the support of the new version of protocol(4.2)
-- 2013.05.06 Anass El bahri Add type of power supply mib
-- 2013.05.07 Anass El bahri Add Optical receiver type
--
--**************************************************************************
ELECTROLINE-DHT-GLOBAL-FIBERNODE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32, Counter32
FROM SNMPv2-SMI
DisplayString
FROM RFC1213-MIB
TruthValue
FROM SNMPv2-TC
dhtExtensionsMibObjects
FROM ELECTROLINE-DHT-EXTENSIONS-MIB;
dhtGlobalFnIdentMIB MODULE-IDENTITY
LAST-UPDATED "200412100000Z"
ORGANIZATION "Electroline Equipment Inc"
CONTACT-INFO
"Electroline Equipment Inc.
E-mail: support@electroline.com
Telephone:
(514) 374-6335
(800)-461-3344 (Toll-free - North America)
"
DESCRIPTION
"This set of objects monitor and control a GLOBAL fiber node (VTN-200) that may be present and connected to the ECMM-06.
This file includes a control object, and status object.
"
REVISION "200412100000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { dhtExtensionsMibObjects 14 }
--Global Fiber Node Objects
globalFnIdentObjects OBJECT IDENTIFIER ::= { dhtGlobalFnIdentMIB 1 }
--- ******************
--- * Return lasers
--- ******************
--number of return lazer
globalFnNumberReturnLaser OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the return laser table.
A zero entry means the table does not exist and the functional
area is not present in this device."
::= { globalFnIdentObjects 1 }
--return laser table
globalFnReturnLaserTable OBJECT-TYPE
SYNTAX SEQUENCE OF GlobalFnReturnLaserTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about return lasers in a fiber node"
::= { globalFnIdentObjects 2 }
--return lasers entry
globalFnReturnLaserTableEntry OBJECT-TYPE
SYNTAX GlobalFnReturnLaserTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information about each return laser in a fiber node."
INDEX {globalFnReturnLaserIndex}
::= { globalFnReturnLaserTable 1 }
GlobalFnReturnLaserTableEntry ::=
SEQUENCE
{
globalFnReturnLaserIndex
INTEGER,
globalFnReturnLaserState
INTEGER,
globalFnReturnLaserRFLevel
INTEGER,
globalFnReturnLaserRFState
INTEGER,
globalFnReturnLaserRFControl
INTEGER,
globalFnReturnLaserElecAttenuator
INTEGER,
}
--return laser index
globalFnReturnLaserIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Index into globalFnRetrunLaserTable.
a VTN-200 fiber node may have 4 transmitters, numbered 1,2,3,4 in modules 1,2. each module contain two transmitters.
Module1 can contain RTX1 , RTX2 and Module2 can contain RTX3 , RTX4.
"
::= {globalFnReturnLaserTableEntry 1}
--return laser state
globalFnReturnLaserState OBJECT-TYPE
SYNTAX INTEGER { unavailable(1), available(2) }
ACCESS read-only
STATUS current
DESCRIPTION
"Report the state of this return transmitter.
if the state is available, this return transmitter is plugged in the module.
if the state is unavailable, this return transmitter is not plugged in the module.
"
::= {globalFnReturnLaserTableEntry 2}
--return laser RF level
globalFnReturnLaserRFLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Return a laser RF Level. Units in 1 dBmV."
::= {globalFnReturnLaserTableEntry 3}
--return laser RF control
globalFnReturnLaserRFControl OBJECT-TYPE
SYNTAX INTEGER {off(1),on(2)}
ACCESS read-write
STATUS current
DESCRIPTION
"control the return laser RF path"
::= {globalFnReturnLaserTableEntry 4}
--return laser electronic attenuator value
globalFnReturnLaserElecAttenuator OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"Return a laser electronic attenuator value. Units in 0.5 dB.
user can set a return transmitter electronic value by setting this variable.
"
::= {globalFnReturnLaserTableEntry 5}
--- ******************
--- * Optical receivers
--- ******************
--number of optical receivers
globalFnNumberOpticalReceiver OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the optical receiver table.
A zero entry means the table does not exist and the functional
area is not present in the device."
::= { globalFnIdentObjects 3 }
-- optical receivers AGC ON/OFF
globalFnOpticalReceiverAGCState OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-only
STATUS current
DESCRIPTION
"Reports the optical receivers AGC state.
0 = Optical receiver1 AGC OFF;Optical receiver2 AGC OFF
1 = Optical receiver1 AGC OFF;Optical receiver2 AGC ON
2 = Optical receiver1 AGC ON;Optical receiver2 AGC OFF
3 = Optical receiver1 AGC ON;Optical receiver2 AGC ON."
::= {globalFnIdentObjects 4}
--Opyical receiver AGC control
globalFnOpticalReceiverAGCControl OBJECT-TYPE
SYNTAX INTEGER {frx1-agc-off(1),frx1-agc-on(2),frx2-agc-off(3),frx2-agc-on(4)}
ACCESS read-write
STATUS current
DESCRIPTION
"control the FRX1 and FRX2 AGC."
::= {globalFnIdentObjects 5}
--Optical receivers table
globalFnOpticalReceiverTable OBJECT-TYPE
SYNTAX SEQUENCE OF GlobalFnOpticalReceiverTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about Optical receivers in a fiber node"
::= { globalFnIdentObjects 6 }
--Optical receivers entry
globalFnOpticalReceiverTableEntry OBJECT-TYPE
SYNTAX GlobalFnOpticalReceiverTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information about each optical receiver in a fiber node."
INDEX {globalFnOpticalReceiverIndex}
::= { globalFnOpticalReceiverTable 1 }
GlobalFnOpticalReceiverTableEntry ::=
SEQUENCE
{
globalFnOpticalReceiverIndex
INTEGER,
globalFnOpticalReceiverState
INTEGER,
globalFnOpticalReceiverType
DisplayString,
globalFnOpticalReceiverRFLevel
INTEGER,
globalFnOpticalReceiverRFControl
INTEGER,
globalFnOpticalReceiverElecAttenuator
INTEGER,
}
--Optical receiver index
globalFnOpticalReceiverIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Index into globalFnOpticalReceiverTable.
a VTN-200 fiber node may have 4 receivers, numbered 1,2,3,4 in modules 1,2. each module contain two receivers.
Module1 can contain FRX1 , FRX2 and Module2 can contain FRX3 , FRX4."
::= {globalFnOpticalReceiverTableEntry 1}
--Optical receiver state
globalFnOpticalReceiverState OBJECT-TYPE
SYNTAX INTEGER { unavailable(1), available(2) }
ACCESS read-only
STATUS current
DESCRIPTION
"Report the state of this optical receiver.
if the state is available, this optical receiver is plugged in the module.
if the state is unavailable, this optical receiver is not plugged in the module.
"
::= {globalFnOpticalReceiverTableEntry 2}
--Optical receiver type
globalFnOpticalReceiverType OBJECT-TYPE
SYNTAX DisplayString ( SIZE(0..20) )
ACCESS read-only
STATUS optional
DESCRIPTION
"Type of optical receiver. Some valid values are: , standard frx,low input frx."
::= { globalFnOpticalReceiverTableEntry 3 }
--Optical receiver RF level
globalFnOpticalReceiverRFLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Return an optical receiver RF Level. Units in 1 dBmV."
::= {globalFnOpticalReceiverTableEntry 4}
--Optical receiver RF control
globalFnOpticalReceiverRFControl OBJECT-TYPE
SYNTAX INTEGER { off(1),on(2)}
ACCESS read-write
STATUS current
DESCRIPTION
"Control the optical receiver RF path"
::= {globalFnOpticalReceiverTableEntry 5}
--Optical receiver electronic attenuator
globalFnOpticalReceiverElecAttenuator OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"Return an optical receiver electronic attenuator value. Units in 0.5 dB.
user can set optical receiver electronic value by setting this variable.
"
::= {globalFnOpticalReceiverTableEntry 6}
--- ******************
--- * wing switchs
--- ******************
--number of wing switch
globalFnNumberWingSwitch OBJECT-TYPE
SYNTAX INTEGER ( 0..8 )
ACCESS read-only
STATUS current
DESCRIPTION
"Number of wing switches in this fiber node
A zero entry means the table does not exist and the functional
area is not present in the device."
::= { globalFnIdentObjects 7 }
--wing switch table
globalFnWingSwitchTable OBJECT-TYPE
SYNTAX SEQUENCE OF GlobalFnWingSwitchTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
" table containing information about wing switches in this fiber node"
::= { globalFnIdentObjects 8 }
--wing switch entry
globalFnWingSwitchTableEntry OBJECT-TYPE
SYNTAX GlobalFnWingSwitchTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"List of information about each wing switch."
INDEX {globalFnWingSwitchIndex}
::= { globalFnWingSwitchTable 1 }
GlobalFnWingSwitchTableEntry ::=
SEQUENCE
{
globalFnWingSwitchIndex
INTEGER,
globalFnWingSwitchState
INTEGER,
globalFnWingSwitchControl
INTEGER,
}
--wing switch index
globalFnWingSwitchIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Index into the dhtGlobalFnWingSwitchTable."
::= {globalFnWingSwitchTableEntry 1}
--wing switch state
globalFnWingSwitchState OBJECT-TYPE
SYNTAX INTEGER {unavailable(0), off(1), sixDb(2), normal(3)}
ACCESS read-only
STATUS current
DESCRIPTION
"Reports the state of the wing switch.
unavailable(0) indicate that the wing switch is unavailable.
off(1) indicate that the wing switch is off.
sixDb(2) indicate that the RF level of the node RF port is 6 db.
normal(3) indicate that the wing switch is normal.
"
::= {globalFnWingSwitchTableEntry 2}
--wing switch control
globalFnWingSwitchControl OBJECT-TYPE
SYNTAX INTEGER {off(1), sixDb(2), normal(3)}
ACCESS read-write
STATUS current
DESCRIPTION
"control the wing switch."
::= {globalFnWingSwitchTableEntry 3}
--- ******************
--- * RF routers
--- ******************
-- number of Rf router
globalFnNumberRFRouter OBJECT-TYPE
SYNTAX INTEGER ( 0..8 )
ACCESS read-only
STATUS current
DESCRIPTION
"Number of RF router in this fiber node
A zero entry means the table does not exist and the functional
area is not present in the device."
::= { globalFnIdentObjects 9 }
-- RF router table
globalFnRFRouterTable OBJECT-TYPE
SYNTAX SEQUENCE OF GlobalFnRFRouterTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
" table containing information about RF routers in this fiber node"
::= { globalFnIdentObjects 10 }
-- RF router table
globalRFRouterTableEntry OBJECT-TYPE
SYNTAX GlobalFnRFRouterTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"List of information about each RF router."
INDEX { globalFnRFRouterIndex }
::= { globalFnRFRouterTable 1 }
GlobalFnRFRouterTableEntry ::=
SEQUENCE
{
globalFnRFRouterIndex
INTEGER,
globalFnRFRouterType
DisplayString,
globalFnRFRouterDownstreamSwitchState
INTEGER,
globalFnRFRouterDownstreamSwitchControl
INTEGER,
globalFnRFRouterDownstreamControlTypeState
INTEGER,
globalFnRFRouterDownstreamControlTypeSetting
INTEGER,
globalFnRFRouterUptreamSwitchState
INTEGER,
globalFnRFRouterUptreamSwitchControl
INTEGER,
globalFnRFRouterUpstreamControlTypeState
INTEGER,
globalFnRFRouterUpstreamControlTypeSetting
INTEGER,
}
-- RF router index
globalFnRFRouterIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Index into the dhtGlobalFnRFRouterTable."
::= {globalRFRouterTableEntry 1}
-- RF router type
globalFnRFRouterType OBJECT-TYPE
SYNTAX DisplayString ( SIZE(0..20))
ACCESS read-only
STATUS current
DESCRIPTION
"RF router type
0 = Not Present.
1 = Router Reserved Type1.
2 = Router Reserved Type2.
3 = Router Reserved Type3.
4 = Router Reserved Type4.
"
::= {globalRFRouterTableEntry 2}
-- RF router downstream switch state
globalFnRFRouterDownstreamSwitchState OBJECT-TYPE
SYNTAX INTEGER {unavailable(0), redundantMode(1), segmentation(2) }
ACCESS read-only
STATUS current
DESCRIPTION
"Reports the state of the downstream redundant & segmentation switch.
unavailable(0) indicates that the switch is unavailable.
redundantMode(1) indicates that the switch is in redundant mode.
segmentation(2) indicates that the switch is in segmentation mode."
::= {globalRFRouterTableEntry 3}
-- RF router downstream switch control
globalFnRFRouterDownstreamSwitchControl OBJECT-TYPE
SYNTAX INTEGER {redundantMode(1), segmentation(2) }
ACCESS read-write
STATUS current
DESCRIPTION
"control the downstream switch."
::= {globalRFRouterTableEntry 4}
-- RF router downstream control type state
globalFnRFRouterDownstreamControlTypeState OBJECT-TYPE
SYNTAX INTEGER {remote(0), local(1)}
ACCESS read-only
STATUS current
DESCRIPTION
"Reports the control mode of the downstream redundant & segmentation switch.
remote(0) indicates that the switch is in remote mode.
local(1) indicates that the switch is in local mode."
::= {globalRFRouterTableEntry 5}
-- RF router downstream control type setting
globalFnRFRouterDownstreamControlTypeSetting OBJECT-TYPE
SYNTAX INTEGER {remote(0), local(1)}
ACCESS read-write
STATUS current
DESCRIPTION
"Control the downstream redundant & segmentation switch mode."
::= {globalRFRouterTableEntry 6}
-- RF router upstream switch state
globalFnRFRouterUptreamSwitchState OBJECT-TYPE
SYNTAX INTEGER {unavailable(0), redundantMode(1), segmentation(2) }
ACCESS read-only
STATUS current
DESCRIPTION
"Reports the state of the upstream redundant & segmentation switch state.
unavailable(0) indicates that the switch is unavailable.
redundantMode(1) indicates that the switch is in redundant mode.
segmentation(2) indicates that the switch is in segmentation mode."
::= {globalRFRouterTableEntry 7}
-- RF router upstream switch control
globalFnRFRouterUptreamSwitchControl OBJECT-TYPE
SYNTAX INTEGER {redundantMode(1), segmentation(2) }
ACCESS read-write
STATUS current
DESCRIPTION
"control the upstream switch."
::= {globalRFRouterTableEntry 8}
-- RF router upstream control type state
globalFnRFRouterUpstreamControlTypeState OBJECT-TYPE
SYNTAX INTEGER {remote(0), local(1)}
ACCESS read-only
STATUS current
DESCRIPTION
"Reports the control mode of the upstream redundant & segmentation switch.
remote(0) indicates that the switch is in remote mode.
local(1) indicates that the switch is in local mode."
::= {globalRFRouterTableEntry 9}
-- RF router upstream control type setting
globalFnRFRouterUpstreamControlTypeSetting OBJECT-TYPE
SYNTAX INTEGER {remote(0), local(1)}
ACCESS read-write
STATUS current
DESCRIPTION
"control the mode of upstream switch."
::= {globalRFRouterTableEntry 10}
--- ******************
--- * RF ports
--- ******************
--number of rf port
globalFnNumberRFPort OBJECT-TYPE
SYNTAX INTEGER ( 0..16 )
ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the RF port table.
A zero entry means the table does not exist and the functional
area is not present in the device."
::= { globalFnIdentObjects 11 }
-- RF link switch state
globalRFLinkSwitchState OBJECT-TYPE
SYNTAX INTEGER ( 0..255 )
ACCESS read-only
STATUS current
DESCRIPTION
"return the RF link switch status
Bit7 = Optical receiver1 RF ON/OFF State
Bit6 = Optical receiver2 RF ON/OFF State
Bit5 = Optical receiver3 RF ON/OFF State
Bit4 = Optical receiver4 RF ON/OFF State
Bit3 = Return laser1 RF ON/OFF State
Bit2 = Return laser2 RF ON/OFF State
Bit1 = Return laser3 RF ON/OFF State
Bit0 = Return laser4 RF ON/OFF State
0 = RF OFF
1 = RF ON
E.g. 0xA0 = 1010 0000 stand for Optical receiver1 Plug in module1&Optical receiver2 Plug in module1 RF ON, and other RF OFF."
::= { globalFnIdentObjects 12 }
--RF reverse link switch state
globalReverseRFLinkSwitchState OBJECT-TYPE
SYNTAX INTEGER ( 0..7 )
ACCESS read-only
STATUS current
DESCRIPTION
"return the reverse RF link switch state
0 = RF Path1 OFF :RF Path2 OFF :RF Path3 OFF
1 = RF Path1 OFF :RF Path2 OFF :RF Path3 ON
2 = RF Path1 OFF :RF Path2 ON :RF Path3 OFF
3 = RF Path1 ON :RF Path2 OFF :RF Path3 OFF
4 = RF Path1 OFF :RF Path2 ON :RF Path3 ON
5 = RF Path1 ON :RF Path2 ON :RF Path3 OFF
6 = RF Path1 ON :RF Path2 OFF :RF Path3 ON
7 = RF Path1 ON :RF Path2 ON :RF Path3 ON."
::= { globalFnIdentObjects 13 }
--RF reverse link switch control
globalReverseRFLinkSwitchControl OBJECT-TYPE
SYNTAX INTEGER { path1-off(1),path1-on(2),path2-off(3),path2-on(4),path3-off(5),path3-on(6)}
ACCESS read-write
STATUS current
DESCRIPTION
"control the reverse link switch path"
::= { globalFnIdentObjects 14 }
--RF ports table
globalFnRFPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF GlobalFnRFPortTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
" table containing information about RF ports in this fiber node"
::= { globalFnIdentObjects 15 }
--RF ports table entry
globalFnRFPortTableEntry OBJECT-TYPE
SYNTAX GlobalFnRFPortTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"List of information about each RF port."
INDEX {globalFnRFPortIndex}
::= { globalFnRFPortTable 1 }
GlobalFnRFPortTableEntry ::=
SEQUENCE
{
globalFnRFPortIndex
INTEGER,
globalUpStreamRFLevel
INTEGER,
globalFnDownStreamRFLevel
INTEGER,
}
--RF port index
globalFnRFPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Index into the fnRFPortTable.
This index is application specific. It can be either the nth port, or a port number.
For example, a node may have 4 ports, numbered 1, 3, 4, 6. Thus, the indexes could be
.1, .3, .4, .6, OR .1, .2, .3., .4. In the latter case, the port name is critical."
::= {globalFnRFPortTableEntry 1}
--RF port upstream RF level
globalUpStreamRFLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Port Reverse RF Level. Units in 1 dBmV."
::= { globalFnRFPortTableEntry 2}
--RF port downstream RF level
globalFnDownStreamRFLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Port Forward RF Level. Units in 1 dBmV."
::= { globalFnRFPortTableEntry 3}
--- ***********************
--- * electronic attenuator
--- ***********************
-- number of electronic attenuator
globalFnNumberElecAttenuator OBJECT-TYPE
SYNTAX INTEGER (0..2)
ACCESS read-only
STATUS current
DESCRIPTION
"return the number of electronic attenuator in this fiber node."
::= { globalFnIdentObjects 16 }
-- electronic attenuator table
globalFnElecAttenuatorTable OBJECT-TYPE
SYNTAX SEQUENCE OF GlobalFnElecAttenuatorTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about electronic attenuator in this fiber node"
::= { globalFnIdentObjects 17 }
-- electronic attenuator entry
globalFnElecAttenuatorTableEntry OBJECT-TYPE
SYNTAX GlobalFnElecAttenuatorTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information about each electronic attenuator in this fiber node."
INDEX {globalFnElecAttenuatorIndex}
::= { globalFnElecAttenuatorTable 1 }
GlobalFnElecAttenuatorTableEntry ::=
SEQUENCE
{
globalFnElecAttenuatorIndex
INTEGER,
globalFnElecAttenuatorValue
INTEGER,
}
-- electronic attenuator index
globalFnElecAttenuatorIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Index into the dhtGlobalFnElecAttenuatorTable."
::= {globalFnElecAttenuatorTableEntry 1}
-- electronic attenuator value
globalFnElecAttenuatorValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"return the attenuator value. Units in 0.5 dB.
user can set electronic attenuator value by writing this variable.
"
::= {globalFnElecAttenuatorTableEntry 2}
--- ***********************
--- * electronic equaslisers
--- ***********************
-- number of electronic equalizer
globalFnNumberElecEqualizer OBJECT-TYPE
SYNTAX INTEGER (0..2)
ACCESS read-only
STATUS current
DESCRIPTION
"return the number of electronic equalizer in this fiber node."
::= { globalFnIdentObjects 18 }
-- electronic equalizer table
globalFnElecEqualizerTable OBJECT-TYPE
SYNTAX SEQUENCE OF GlobalFnElecEqualizerTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about electronic equalizer in a fiber node"
::= { globalFnIdentObjects 19 }
-- electronic equalizer table
globalFnElecEqualizerTableEntry OBJECT-TYPE
SYNTAX GlobalFnElecEqualizerTableEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information about each electronic eqalizer in this fiber node."
INDEX {globalFnElecEqualizerIndex}
::= { globalFnElecEqualizerTable 1 }
GlobalFnElecEqualizerTableEntry ::=
SEQUENCE
{
globalFnElecEqualizerIndex
INTEGER,
globalFnElecEqualizerValue
INTEGER,
}
-- electronic equalizer index
globalFnElecEqualizerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"Index into the dhtGlobalFnElecAttenuatorTable."
::= {globalFnElecEqualizerTableEntry 1}
-- electronic equalizer value
globalFnElecEqualizerValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"return the equalizer value. Units in 0.5 dB.
user can set electronic equaliser value by writing this variable.
"
::= {globalFnElecEqualizerTableEntry 2}
-- optical reveivers AGC offset
globalFnAGCOffsetValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"return the optical receivers AGC offset value.
user can set AGC offset value by writing this variable.
"
::= {globalFnIdentObjects 20}
-- optical reveivers AGC RF level
globalFnAGCRfLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"return the optical receivers AGC RF level value.
user can set AGC RF level by writing this variable.
"
::= {globalFnIdentObjects 21}
-- optical reveivers RF level offset
globalFnRfLevelOffsetValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"return the RF level offset value.
user can set RF level offset value by writing this variable.
"
::= {globalFnIdentObjects 22}
-- fiber internal temperature
globalFnTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"return the fiber node internal temperature."
::= {globalFnIdentObjects 23}
-- fiber node reset
globalFnReset OBJECT-TYPE
SYNTAX INTEGER { reset(1)}
ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to reset the VTN-200 by writing 1 to it.
Other values written to the object have no effect.
Reading the object returns a 1, and has no effect on the unit."
::= {globalFnIdentObjects 24}
-- reset all RTX and FRX modules
globalFnResetFrxRtx OBJECT-TYPE
SYNTAX INTEGER { reset(1)}
ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to reset all RTX and FRX modules by writing 1 to it.
Other values written to the object have no effect.
Reading the object returns a 1, and has no effect on the unit."
::= {globalFnIdentObjects 25}
-- type of power supply
globalFnTypeOfPowerSupply OBJECT-TYPE
SYNTAX INTEGER { linePower(1),mainPower(2),not-defined(0)}
ACCESS read-only
STATUS current
DESCRIPTION
"Report the type of the power supply. "
::= {globalFnIdentObjects 26}
END