-- MY-SYSTEM-MIB.mib: My System MIB file
|
|
--
|
|
-- March 2002, Wuzg
|
|
--
|
|
-- Copyright (c) 2002 by My Networks Co.,Ltd.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
--
|
|
|
|
DES7200-SYSTEM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
Integer32,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
myMgmt
|
|
FROM DES7200-SMI;
|
|
|
|
mySystemMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200203200000Z"
|
|
ORGANIZATION "D-Link Crop."
|
|
CONTACT-INFO
|
|
"
|
|
http://support.dlink.com"
|
|
DESCRIPTION
|
|
"This module defines my system mibs."
|
|
REVISION "200203200000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { myMgmt 1}
|
|
|
|
mySystemMIBObjects OBJECT IDENTIFIER ::= { mySystemMIB 1 }
|
|
|
|
mySystemHwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the Revision number of hardware resides
|
|
on the FastSwitch."
|
|
::= { mySystemMIBObjects 1 }
|
|
|
|
mySystemSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the Revision number of software resides
|
|
on the FastSwitch."
|
|
::= { mySystemMIBObjects 2 }
|
|
|
|
mySystemBootVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the Revision number of BOOT software resides
|
|
on the FastSwitch."
|
|
::= { mySystemMIBObjects 3 }
|
|
|
|
mySystemSysCtrlVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the Revision number of CTRL software resides
|
|
on the FastSwitch."
|
|
::= { mySystemMIBObjects 4 }
|
|
|
|
mySystemParametersSave OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Save all parameters changed in configuration by setting
|
|
this object to any value but 0, set its value to 0 will
|
|
cause no action of agent, otherwise all changes of
|
|
prarameters will be saved for retrive when system is
|
|
reset, if parameter is changed but not saved all changes
|
|
will come to their original value when system down and up
|
|
again, when query always return value 0."
|
|
::= { mySystemMIBObjects 5 }
|
|
|
|
mySystemOutBandRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
baud9600 (1),
|
|
baud19200 (2),
|
|
baud38400 (3),
|
|
baud57600 (4),
|
|
baud115200 (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determine the console(OutBand) baud rate :
|
|
9600 - 1,19200 - 2, 38300 - 3, 57600 - 4, 115200 - 5,
|
|
when the console baud rate is other value will return value 0."
|
|
::= { mySystemMIBObjects 6 }
|
|
|
|
mySystemReset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object allow perform soft reset of system by setting its
|
|
value to none zero. if a soft resetis performed, after this
|
|
having completed a warm start trap will send to declare the state
|
|
and when queried will always return 0."
|
|
::= { mySystemMIBObjects 7 }
|
|
|
|
mySwitchLayer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
layer2 (1), -- Layer 2 Switch
|
|
layer3 (2), -- Layer 3 Switch
|
|
router(3) -- Router
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Which layer's device the switch in system "
|
|
::= { mySystemMIBObjects 8 }
|
|
|
|
mySystemHwPower OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
rpsNoLink(1),
|
|
rpsLinkAndNoPower(2),
|
|
rpsLinkAndReadyForPower(3),
|
|
rpsLinkAndPower(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of power."
|
|
::= { mySystemMIBObjects 9 }
|
|
|
|
mySystemHwFan OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
work(1),
|
|
stop(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of fan."
|
|
::= { mySystemMIBObjects 10 }
|
|
|
|
--The mySystemOutBandTimeout is obsoleted after 2007.9
|
|
mySystemOutBandTimeout OBJECT-TYPE
|
|
SYNTAX Integer32(0..3600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The timeout of console.0 indicate that timeout function is disabled."
|
|
::= { mySystemMIBObjects 11 }
|
|
|
|
--The mySystemTelnetTimeout is obsoleted after 2007.9
|
|
mySystemTelnetTimeout OBJECT-TYPE
|
|
SYNTAX Integer32(0..3600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The timeout of telnet.0 indicate that timeout function is disabled."
|
|
::= { mySystemMIBObjects 12 }
|
|
|
|
mySystemMainFile OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the name of main file on the FastSwitch."
|
|
::= { mySystemMIBObjects 13 }
|
|
|
|
mySystemCurrentPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the current power of the FastSwitch."
|
|
::= { mySystemMIBObjects 14 }
|
|
|
|
mySystemRemainPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the remain power of the FastSwitch."
|
|
::= { mySystemMIBObjects 15 }
|
|
|
|
mySystemTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the temperature of the FastSwitch."
|
|
::= { mySystemMIBObjects 16 }
|
|
|
|
mySystemElectricalSourceNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the electrical source number of the FastSwitch."
|
|
::= { mySystemMIBObjects 17 }
|
|
|
|
mySystemElectricalSourceIsNormalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MySystemElectricalSourceIsNormalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of electrical source entries. Each object displays
|
|
whether different electrical sources are normal or not."
|
|
::= { mySystemMIBObjects 18 }
|
|
|
|
mySystemElectricalSourceIsNormalEntry OBJECT-TYPE
|
|
SYNTAX MySystemElectricalSourceIsNormalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays whether different electrical sources are normal or not."
|
|
INDEX { mySystemElectricalSourceIsNormalIndex }
|
|
::= { mySystemElectricalSourceIsNormalTable 1 }
|
|
|
|
MySystemElectricalSourceIsNormalEntry ::=
|
|
SEQUENCE {
|
|
mySystemElectricalSourceIsNormalIndex Integer32,
|
|
mySystemElectricalSourceIsNormal INTEGER,
|
|
mySystemElectricalSourceName DisplayString
|
|
}
|
|
|
|
mySystemElectricalSourceIsNormalIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a electrical source."
|
|
::= { mySystemElectricalSourceIsNormalEntry 1 }
|
|
|
|
mySystemElectricalSourceIsNormal OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noexist (1), --no exist
|
|
existnopower (2), -- exist no power
|
|
existreadypower (3), --exist ready power
|
|
normal (4), --normal
|
|
powerbutabnormal (5), --power but abnormal
|
|
unknow (6) --unknow
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays whether an electrical source is normal or not."
|
|
::= { mySystemElectricalSourceIsNormalEntry 2 }
|
|
|
|
mySystemElectricalSourceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of electrical source"
|
|
::= { mySystemElectricalSourceIsNormalEntry 3 }
|
|
|
|
mySystemCurrentVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the current voltage of the FastSwitch."
|
|
::= { mySystemMIBObjects 19 }
|
|
|
|
mySystemFanNUM OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the number of fan on the FastSwitch."
|
|
::= { mySystemMIBObjects 20 }
|
|
|
|
mySystemFanIsNormalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MySystemFanIsNormalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of fan entries. Each object displays
|
|
whether different fans are normal or not."
|
|
::= { mySystemMIBObjects 21 }
|
|
|
|
mySystemFanIsNormalEntry OBJECT-TYPE
|
|
SYNTAX MySystemFanIsNormalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays whether different fans are normal or not."
|
|
INDEX { mySystemFanIsNormalIndex }
|
|
::= { mySystemFanIsNormalTable 1 }
|
|
|
|
MySystemFanIsNormalEntry ::=
|
|
SEQUENCE {
|
|
mySystemFanIsNormalIndex Integer32,
|
|
mySystemFanIsNormal INTEGER,
|
|
mySystemFanName DisplayString
|
|
}
|
|
|
|
mySystemFanIsNormalIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a fan."
|
|
::= { mySystemFanIsNormalEntry 1 }
|
|
|
|
mySystemFanIsNormal OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noexist (1), --no exist
|
|
existnopower (2), -- exist no power
|
|
existreadypower (3), --exist ready power
|
|
normal (4), --normal
|
|
powerbutabnormal (5), --power but abnormal
|
|
unknow (6) --unknow
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays whether an fan is normal or not."
|
|
::= { mySystemFanIsNormalEntry 2 }
|
|
|
|
mySystemFanName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of fan"
|
|
::= { mySystemFanIsNormalEntry 3 }
|
|
|
|
mySystemReloadTimeRemain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the remain time of reloading on the FastSwitch."
|
|
::= { mySystemMIBObjects 22 }
|
|
|
|
mySystemTemperatureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MySystemTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of temperature entries. Each object displays
|
|
the temperature information."
|
|
::= { mySystemMIBObjects 23 }
|
|
|
|
mySystemTemperatureEntry OBJECT-TYPE
|
|
SYNTAX MySystemTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the temperature information."
|
|
INDEX { mySystemTemperatureIndex }
|
|
::= { mySystemTemperatureTable 1 }
|
|
|
|
MySystemTemperatureEntry ::=
|
|
SEQUENCE {
|
|
mySystemTemperatureIndex Integer32,
|
|
mySystemTemperatureName DisplayString,
|
|
mySystemTemperatureCurrent Integer32,
|
|
mySystemTemperatureWarningVaule Integer32,
|
|
mySystemTemperatureCritialVaule Integer32
|
|
}
|
|
|
|
mySystemTemperatureIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a device's temperature information."
|
|
::= { mySystemTemperatureEntry 1 }
|
|
|
|
mySystemTemperatureName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual name assigned to a temperature chip"
|
|
::= { mySystemTemperatureEntry 2 }
|
|
|
|
mySystemTemperatureCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the current temperature of the FastSwitch.The temperature display
|
|
is not supported for the current temperature returns to 0."
|
|
::= { mySystemTemperatureEntry 3 }
|
|
|
|
mySystemTemperatureWarningVaule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The first warning of temperature of FastSwitch."
|
|
::= { mySystemTemperatureEntry 4 }
|
|
|
|
mySystemTemperatureCritialVaule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The second warning of temperature of FastSwitch."
|
|
::= { mySystemTemperatureEntry 5 }
|
|
|
|
mySystemSerialno OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the serial number resides
|
|
on the FastSwitch."
|
|
::= { mySystemMIBObjects 24 }
|
|
|
|
mySystemVersionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MySystemVersionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of system version entries. Each object displays
|
|
the system version information."
|
|
::= { mySystemMIBObjects 25 }
|
|
|
|
mySystemVersionEntry OBJECT-TYPE
|
|
SYNTAX MySystemVersionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the system version information."
|
|
INDEX { mySystemVersionIndex }
|
|
::= { mySystemVersionTable 1 }
|
|
|
|
MySystemVersionEntry ::=
|
|
SEQUENCE {
|
|
mySystemVersionIndex Unsigned32,
|
|
mySystemVersionName DisplayString,
|
|
mySystemVersionSwBoot DisplayString,
|
|
mySystemVersionSwCtrl DisplayString,
|
|
mySystemVersionSwMain DisplayString,
|
|
mySystemVersionHw DisplayString,
|
|
mySystemVersionSerialno DisplayString
|
|
}
|
|
|
|
mySystemVersionIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a device's system version information."
|
|
::= { mySystemVersionEntry 1 }
|
|
|
|
mySystemVersionName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual name assigned to a system version chip"
|
|
::= { mySystemVersionEntry 2 }
|
|
|
|
mySystemVersionSwBoot OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the software boot system version of the FastSwitch."
|
|
::= { mySystemVersionEntry 3 }
|
|
|
|
mySystemVersionSwCtrl OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the software ctrl system version of the FastSwitch."
|
|
::= { mySystemVersionEntry 4 }
|
|
|
|
mySystemVersionSwMain OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the software main system version of the FastSwitch."
|
|
::= { mySystemVersionEntry 5 }
|
|
|
|
mySystemVersionHw OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the hardware system version of the FastSwitch."
|
|
::= { mySystemVersionEntry 6 }
|
|
|
|
mySystemVersionSerialno OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the serial number of the FastSwitch."
|
|
::= { mySystemVersionEntry 7 }
|
|
|
|
mySystemMIBTraps OBJECT IDENTIFIER ::= { mySystemMIB 2 }
|
|
|
|
mySystemHardChangeDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description of hard change"
|
|
::= { mySystemMIBTraps 1 }
|
|
|
|
mySystemHardChangeDetected NOTIFICATION-TYPE
|
|
OBJECTS {mySystemHardChangeDesc}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System hardware has changed include number of devices or number of modules
|
|
or the place or type of the module is change."
|
|
::= { mySystemMIBTraps 2 }
|
|
|
|
mySystemPowerStateChange NOTIFICATION-TYPE
|
|
OBJECTS {mySystemHwPower}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"while the state of power changed, then this trap will be sent."
|
|
::= { mySystemMIBTraps 3 }
|
|
|
|
mySystemFanStateChange NOTIFICATION-TYPE
|
|
OBJECTS {mySystemHwFan}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"while the state of fan changed, then this trap will be sent."
|
|
::= { mySystemMIBTraps 4 }
|
|
|
|
|
|
mySystemMIBConformance OBJECT IDENTIFIER ::= { mySystemMIB 3 }
|
|
mySystemMIBCompliances OBJECT IDENTIFIER ::= { mySystemMIBConformance 1 }
|
|
mySystemMIBGroups OBJECT IDENTIFIER ::= { mySystemMIBConformance 2 }
|
|
|
|
|
|
-- compliance statements
|
|
|
|
mySystemMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the My System MIB"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { mySystemMIBGroup
|
|
}
|
|
::= { mySystemMIBCompliances 1 }
|
|
|
|
-- units of conformance
|
|
|
|
mySystemMIBGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
mySystemHwVersion,
|
|
mySystemSwVersion,
|
|
mySystemBootVersion,
|
|
mySystemSysCtrlVersion,
|
|
mySystemParametersSave,
|
|
mySystemReset,
|
|
mySystemOutBandRate,
|
|
mySwitchLayer
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing system information and
|
|
opertion to a My agent."
|
|
::= { mySystemMIBGroups 1 }
|
|
|
|
END
|