-- DES3225G Switch MIB Ver 0.01 1999/06/16
-- History
-- Version 0.01
-- Date 09/08/1999
-- 1. New add swDevCtrlTableLockState ,swPortCtrlLockState ,swPortCtrlBroadcastRisingThr
-- and swPortCtrlBroadcastFallingThr objects.
-- 2. Change swDevCtrlAddrLookupModes object to swDevCtrlAddrLookupModesAndHitRate object.
-- 3. New add swDevCtrlUploadImageFileName and swDevCtrlUploadImage objects . For image
-- file download function.
-- Date 09/30/1999
-- 1. Modify swPortCtrlBroadcastRisingThr and swPortCtrlBroadcastFallingThr object's range.
-- 2. Modify swPortCtrlBroadcastRisingThr and swPortCtrlBroadcastFallingThr object's
-- setting.
-- Date 11/11/1999
-- 1. Modify swDevCtrlTableLockState and swPortCtrlLockState objects. When swVlanInfoStatus
-- is in MAC-Base VLAN mode, these objects are always disabled.
DES3225G-MIB
DEFINITIONS ::= BEGIN
IMPORTS
enterprises, TimeTicks, Counter FROM RFC1155-SMI
OBJECT-TYPE FROM RFC-1212
DisplayString FROM RFC1213-MIB
TRAP-TYPE FROM RFC-1215;
MacAddress ::= OCTET STRING(SIZE(6))
dlink OBJECT IDENTIFIER ::= { enterprises 171 }
dlink-products OBJECT IDENTIFIER ::= { dlink 10 }
dlink-Des3225gProd OBJECT IDENTIFIER ::= { dlink-products 24 }
swProperty OBJECT IDENTIFIER ::= { dlink-Des3225gProd 1 }
swModule OBJECT IDENTIFIER ::= { swProperty 1 }
dlink-mgmt OBJECT IDENTIFIER ::= { dlink 11 }
des3225gSeries OBJECT IDENTIFIER ::= { dlink-mgmt 24 }
swDevPackage OBJECT IDENTIFIER ::= { des3225gSeries 1 }
swModulePackage OBJECT IDENTIFIER ::= { des3225gSeries 2 }
swPortPackage OBJECT IDENTIFIER ::= { des3225gSeries 3 }
swFdbPackage OBJECT IDENTIFIER ::= { des3225gSeries 4 }
-- ********************************************************************
-- swDevPackage OBJECT IDENTIFIER ::= { des3225gSeries 1 }
-- ********************************************************************
swDevInfo OBJECT IDENTIFIER ::= { swDevPackage 1 }
swDevInfoSystemUpTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime at the time the switch entered its
current operational state. If the current state was entered
prior to the last re-initialization, then this object contains
a zero value. This value is in units of seconds."
::= { swDevInfo 1 }
swDevInfoMaxNumOfModule OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of modules in this device."
::= { swDevInfo 2 }
swDevInfoTotalNumOfModule OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current actual number of modules in this device.The values range is
1..swDevInfoMaxNumOfModule."
::= { swDevInfo 3 }
swDevInfoTotalNumOfPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports within this switch. This value is the sum
of the ports within this switch."
::= { swDevInfo 4 }
swDevInfoNumOfPortInUse OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports in this switch connected to the segment or
the end stations."
::= { swDevInfo 5 }
swDevInfoConsoleInUse OBJECT-TYPE
SYNTAX INTEGER {
other(1),
in-use(2),
not-in-use(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This usage indication of console system."
::= { swDevInfo 6 }
swDevInfoSystemLedStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..127))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is a set of system LED indications. The first four octets is
defined as system LED. The first LED is power LED. The second LED
is console LED. The third LED is GIGA module existing LED. The fourth LED
is GIGA module link LED. The other octets following the fourth octets
are the port LED. Every two bytes are presented to a port. The first
byte is presentd to the Link/Activity LED. The second byte is presented
to the Speed LED.
There is one byte per LED.
The most significant bit is used for blink/solid:
Off = The LED is lit permanently.
On = The LED blinks.
The three least significant bits are used for color:
1 = not lit,
2 = green,
3 = yellow,(orange)
4 = blue,
5 = red,
0+6+7 not used
The four remaining bits are currently unused and must be 0.
The lastest two octects are defined as slot module type. The first octect
is slot 1 module type. The second octect is slot 2 module type, and so on.
The module type representation for each byte is listed below:
1 = no slot module,
2 = 1 port BNC,
3 = 2 port Fiber MTRJ,
4 = 2 port TX UTP,
5 = 1 port Fiber SC,
6 = Gigabit
other not used"
::= { swDevInfo 7 }
swDevInfoSaveCfg OBJECT-TYPE
SYNTAX INTEGER {
other(1),
proceeding(2),
completed(3),
changed-not-save(4),
failed(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the status of the device configuration.
other(1) - this entry is currently in use but the conditions
under which it will remain so are different from each
of the following values.
proceeding(2) - the device configuration is saving into the NV-RAM.
completed(3) <20>V all of the device configuration parameters have been
saved into NV-RAM.
changed-not-save <20>V some of the device configuration parameters have
been changed but not saved into NV-RAM.
failed(5) - The processing of saving device configuration is failed."
::= { swDevInfo 8 }
-- ***************************************************
swDevCtrl OBJECT IDENTIFIER ::= { swDevPackage 2 }
swDevCtrlStpState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object can be enabled or disabled spanning tree algorithm
during runtime of the system. When the device is in 802.1Q Vlan
mode, this object will be enabled and cannot be disabled."
::= { swDevCtrl 1 }
swDevIGMPCaptureState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates Internet Group Management Protocol (IGMP) capture
function is enabled or disabled."
::= { swDevCtrl 2 }
swDevCtrlPartitionModeState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object used to enable or disable port auto partition. When the
object apply for all ports of the device"
::= { swDevCtrl 3 }
swDevCtrlTableLockState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates whether the address table is locked.
In other words, the address table doesn't learn any more new address.
The aging timer is suspended when the address table is locked. As long
as the table is locked, all of the frames are dropped if the destination
can not be found in the address.When swVlanInfoStatus is in MAC-Base
VLAN mode, this object is always disabled."
::= { swDevCtrl 4 }
swDevCtrlSaveCfg OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION
"As the object is set, the current device configuration is save
into to NV-RAM."
::= { swDevCtrl 5 }
swDevCtrlHOLState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The object provides a way to prevent HOL (Head Of Line) blocking
between ports. HOL protection may prevent forwarding a packet to
a blocking port.The idea relies on the assumption that it is better
to discard packets destined to blocking ports, then to let them consume
more and more buffers in the input-port's Rx-counters because eventually
these input ports may become totally blocked. The meanings of the values
are:
other(1) - this entry is currently in use but the conditions under
which it will remain so are different from each of the following
values.
disabled(2) - HOL function disable for device.
enabled(3) - HOL function enable for device."
::= { swDevCtrl 6 }
swDevCtrlAddrLookupModesAndHitRate OBJECT-TYPE
SYNTAX INTEGER {
level0(1),
level1(2),
level2(3),
level3(4),
level4(5),
level5(6),
level6(7),
level7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"According to the differnet address looke mode setting, to enlarge the
address table size is possible in device. But there is side effect as
the higher level you have, the lower thorughput device has. That means
Level 0 get the smallest table size, but get better performace. We
recommand the user use the Level 1 as defualt setting."
::= { swDevCtrl 7 }
swDevCtrlUploadImageFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of the image file to be uploaded from the device to TFTP server
when enabling image upload function (by writing swDevCtrlUploadImage)."
::= { swDevCtrl 8 }
swDevCtrlUploadImage OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Image file upload control. Writing it by any value will
immediately invoke image upload function."
::= { swDevCtrl 9 }
-- ***************************************************
swDevAlarm OBJECT IDENTIFIER ::= { swDevPackage 3 }
swDevAlarmPartition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Depending on this object, the device send a trap or not when
any one of the device's ports was partitioned."
::= { swDevAlarm 1 }
swDevAlarmNewRoot OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When the device has become the new root of the Spanning Tree, this
object decide whether to send a new root trap."
::= { swDevAlarm 2 }
swDevAlarmTopologyChange OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object determine to send a trap or not when the switch topology
was changed. If the object is enabled(3), the topologyChange trap is
sent by the device when any of its configured ports transitions from
the Learning state to the Forwarding state, or from the Forwarding state
to the Blocking state. For the same port tranition, the device doesn't
send the trap if this object value is disabled or other."
::= { swDevAlarm 3 }
swDevAlarmLinkChange OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object determine to send a trap or not when the link
was changed. If the object is enabled(3), the Link Change trap is
sent by the device when any of its ports link change. The device doesn't
send the trap if this object value is disabled or other."
::= { swDevAlarm 4 }
-- ********************************************************************
-- swModulePackage OBJECT IDENTIFIER ::= { des3225gSeries 2 }
-- ********************************************************************
swModuleInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwModuleInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains information about every module."
::= { swModulePackage 1 }
swModuleInfoEntry OBJECT-TYPE
SYNTAX SwModuleInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information for each module of the device."
INDEX { swModuleInfoIndex }
::= { swModuleInfoTable 1 }
SwModuleInfoEntry ::=
SEQUENCE {
swModuleInfoIndex
INTEGER,
swModuleInfoDesc
DisplayString,
swModuleInfoType
INTEGER,
swModuleInfoTotalNumOfPort
INTEGER,
swModuleInfoNumOfPortInUse
INTEGER,
swModuleInfoPortLedStatus
OCTET STRING
}
swModuleInfoIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates switch module number.(1..swDevInfoMaxNumOfModule)"
::= { swModuleInfoEntry 1 }
swModuleInfoDesc OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the module for memorization ."
::= { swModuleInfoEntry 2 }
swModuleInfoType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
baseModule-UTP(2),
optionModule-2PortFiber-MTRJ(3),
optionModule-2PortTX-UTP(4),
optionModule-1PortFiber-SC(5),
optionModule-1000Base-SX(6),
optionModule-1000Base-LX(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the type of this module."
::= { swModuleInfoEntry 3 }
swModuleInfoTotalNumOfPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports within this module. This value is the sum
of the ports within this module."
::= { swModuleInfoEntry 4 }
swModuleInfoNumOfPortInUse OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports in this module connected to the segment or
the end stations."
::= { swModuleInfoEntry 5 }
swModuleInfoPortLedStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..127))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is a set of module's port LED indications. Every two bytes are
presented to a port. Except the module 3 (Gigabit module) ,the first byte
is presentd to the Link/Activity LED. The second byte is presented to the
Speed LED. For the module 3 ,the first byte is presentd to the module's
existing LED. The second byte is presented to the Link/Activity LED.
There is one byte per LED.
The most significant bit is used for blink/solid:
Off = The LED is lit permanently.
On = The LED blinks.
The three least significant bits are used for color:
1 = not lit,
2 = green,
3 = yellow,(orange)
4 = blue,
5 = red,
0+6+7 not used
The four remaining bits are currently unused and must be 0."
::= { swModuleInfoEntry 6 }
-- ********************************************************************
-- swPortPackage OBJECT IDENTIFIER ::= { des3225gSeries 3 }
-- ********************************************************************
swPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains information about every port."
::= { swPortPackage 1 }
swPortInfoEntry OBJECT-TYPE
SYNTAX SwPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information for each port of the device."
INDEX { swPortInfoModuleIndex ,swPortInfoPortIndex }
::= { swPortInfoTable 1 }
SwPortInfoEntry ::=
SEQUENCE {
swPortInfoModuleIndex
INTEGER,
swPortInfoPortIndex
INTEGER,
swPortInfoType
INTEGER,
swPortInfoLinkStatus
INTEGER,
swPortInfoNwayStatus
INTEGER,
swPortInfoFlowCtrlStatus
INTEGER
}
swPortInfoModuleIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates switch module number.(1..Max module number)"
::= { swPortInfoEntry 1 }
swPortInfoPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the module's port number.(1..Max port number in
the module)"
::= { swPortInfoEntry 2 }
swPortInfoType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
portType-UTP(2),
portType-AUI(3),
portType-Fiber-MTRJ(4),
portType-Fiber-SC(5),
portType-BNC(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the connector type of this port."
::= { swPortInfoEntry 3 }
swPortInfoLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
link-pass(2),
link-fail(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the port link status."
::= { swPortInfoEntry 4 }
swPortInfoNwayStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
half-10Mbps(2),
full-10Mbps(3),
half-100Mbps(4),
full-100Mbps(5),
half-1Gigabps(6),
full-1Gigabps(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the port speed and duplex mode."
::= { swPortInfoEntry 5 }
swPortInfoFlowCtrlStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
flowctrl-disabled(2),
flowctrl-enabled(3),
backpressure-disabled(4),
backpressure-enabled(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the port flow control status."
::= { swPortInfoEntry 6 }
-- *******************************************************
swPortCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwPortCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains control information about every port."
::= { swPortPackage 2 }
swPortCtrlEntry OBJECT-TYPE
SYNTAX SwPortCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of control information for each port of the device."
INDEX { swPortCtrlModuleIndex,swPortCtrlPortIndex }
::= { swPortCtrlTable 1 }
SwPortCtrlEntry ::=
SEQUENCE {
swPortCtrlModuleIndex
INTEGER,
swPortCtrlPortIndex
INTEGER,
swPortCtrlAdminState
INTEGER,
swPortCtrlLinkStatusAlarmState
INTEGER,
swPortCtrlNwayState
INTEGER,
swPortCtrlFlowCtrlState
INTEGER,
swPortCtrlBackPressState
INTEGER,
swPortCtrlLockState
INTEGER,
swPortCtrlPriority
INTEGER,
swPortCtrlStpState
INTEGER,
swPortCtrlHOLState
INTEGER,
swPortCtrlBroadcastRisingThr
INTEGER,
swPortCtrlBroadcastFallingThr
INTEGER,
swPortCtrlBroadcastRisingAct
INTEGER,
swPortCtrlBroadcastFallingAct
INTEGER,
swPortCtrlCleanAllStatisticCounter
INTEGER
}
swPortCtrlModuleIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the device module number.(1..Max module number)"
::= { swPortCtrlEntry 1 }
swPortCtrlPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the module's port number.(1..Max port number in
the module)"
::= { swPortCtrlEntry 2 }
swPortCtrlAdminState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object decide the port enabled or disabled."
::= { swPortCtrlEntry 3 }
swPortCtrlLinkStatusAlarmState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Depending on this object to determine to send a trap or
not when link status changes ."
::= { swPortCtrlEntry 4 }
swPortCtrlNwayState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
nway-enabled(2),
nway-disabled-10Mbps-Half(3),
nway-disabled-10Mbps-Full(4),
nway-disabled-100Mbps-Half(5),
nway-disabled-100Mbps-Full(6),
nway-disabled-1Gigabps-Half(7),
nway-disabled-1Gigabps-Full(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Chose the port speed, duplex mode, and N-Way function mode."
::= { swPortCtrlEntry 5 }
swPortCtrlFlowCtrlState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set IEEE 802.3x compliant flow control function as enabled or disabled.
And IEEE 802.3x compliant flow control function work only when the port
is in full duplex mode.If the port is set Auto-negotiation enabled, the
object stands for flow control capability. The results should be referred
to swPortInfoFlowCtrlStatus object. If the port is in force mode, this
objects is simply used to set the flow control state (on/off). In force
mode, if you change it from enabled to disabled state, it will work after
next system restart. But the flow control changing from disabled to enabled
state, it will immediately work."
::= { swPortCtrlEntry 6 }
swPortCtrlBackPressState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Depending on this object determine to enable or disable the
backpressure function when the port is working in half duplex mode."
::= { swPortCtrlEntry 7 }
swPortCtrlLockState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disable(2),
enable(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The state of this entry. When the swDevCtrlTableLockState object is
enabled, the state is not changed. When swVlanInfoStatus is in
MAC-Base VLAN mode, this object is always disabled.The meanings of
the values are:
other(1) - this entry is currently in use but the conditions under
which it will remain so are different from each of the
following values.
disable(2) - Port lock funtion disable.
enable(3) - Locking a port. Once the port is locked, it will not
learn new SA addresses, and drop unknown/moved-SA packets
forwarding to/from such ports. This is a way to prevent
undesired traffic from being received or transmmited on
the port. Note that locking a port doesn't lock the MAC
address entries associated with the locked port, i.e. the
existing address entries of the locked port will be age
out even though it is locked."
::= { swPortCtrlEntry 8 }
swPortCtrlPriority OBJECT-TYPE
SYNTAX INTEGER {
other(1),
default(2),
force-low-priority(3),
force-high-priority(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The priority queueing for packets received on this port, except for
BPDU/IGMP packets and packets with unknown unicast destination address.
IGMP and BPDU packets are always routed with high priority; packets with
unknown unicast destination addresses are always routed with low priority.
Other packets follow the rules below:
other(1) - this entry is currently in use but the conditions under
which it will remain so are different from each of the
following values.
default(2) - A packet is normally classified as low priority
,unless at least one of the following is true:
.The packet contained a TAG (per 802.1Q definition) with the
priority greater or equal to 4.
.The address-table entry for the destination address had Pd=HIGH.
force-low_priority(3) - A packet is normally classified as low priority.
force-high_priority(4) - A packet is normally classified as high
priority."
::= { swPortCtrlEntry 9 }
swPortCtrlStpState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The state of STP(spanning tree algorithm) operation on this port. That's
meaning the port whether add in the STP. The value enabled(3) indicates
that STP is enabled on this port, as long as swDevCtrlStpState is also
enabled for this device. When disabled(2) but swDevCtrlStpState is still
enabled for the device, STP is disabled on this port : any BPDU packets
received will be discarded and no BPDU packets will be propagated from
the port. When the device is in 802.1Q Vlan mode, this object will be
enabled and cannot be disabled."
::= { swPortCtrlEntry 10 }
swPortCtrlHOLState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The object provides a way to prevent HOL (Head Of Line) blocking
between ports. HOL protection may prevent forwarding a packet to
a blocking port.The idea relies on the assumption that it is better
to discard packets destined to blocking ports, then to let them consume
more and more buffers in the input-port's Rx-counters because eventually
these input ports may become totally blocked. The value enabled(3)
indicates that HOL function is enabled on this port, as long as
swDevCtrlHOLState is also enabled for this device. When disabled(2) but
swDevCtrlHOLState is still enabled for the device, HOL function is disabled
on this port. The meanings of the values are:
other(1) - this entry is currently in use but the conditions under
which it will remain so are different from each of the following
values.
disabled(2) - HOL function disable.
enabled(3) - HOL function enable."
::= { swPortCtrlEntry 11 }
swPortCtrlBroadcastRisingThr OBJECT-TYPE
SYNTAX INTEGER (1..1488000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This allows the user to specify the broadcast packets per second.
Broadcast traffic above this rate activates broadcast storm control
(i.e. swPortCtrlBroadcastRisingAct) on the port. The default value
is 500 broadcast packets per second. The setting must be bigger
than the value in swPortCtrlBroadcastFallingThr."
::= { swPortCtrlEntry 12 }
swPortCtrlBroadcastFallingThr OBJECT-TYPE
SYNTAX INTEGER (1..1488000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This allows the user to specify the broadcast packets per second.
If broadcast traffic is below this rate and rising threshold
condition has been met at least once before this falling threshold
is met, the device will apply the action described in
swPortCtrlBroadcastFallingAct. The default value 250. The setting
must be fewer than the value in swPortCtrlBroadcastRisingThr."
::= { swPortCtrlEntry 13 }
swPortCtrlBroadcastRisingAct OBJECT-TYPE
SYNTAX INTEGER {
other(1),
do-nothing(2),
blocking(3),
blocking-trap(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the system action when broadcast storm
rising threshold is met.
other(1) - this entry is currently in use but the conditions under
which it will remain so are different from each of the following
values.
do-nothing(2) - no action.
blocking(3) - the port can discard any coming broadcast frame.
blocking-trap(4) - the port can discard any coming broadcast frame. And
the device can send a broadcast rising trap."
::= { swPortCtrlEntry 14 }
swPortCtrlBroadcastFallingAct OBJECT-TYPE
SYNTAX INTEGER {
other(1),
do-nothing(2),
forwarding(3),
forwarding-trap(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the device action when broadcast storm
falling threshold is met.
other(1) - this entry is currently in use but the conditions under
which it will remain so are different from each of the following
values.
do-nothing(2) - no action.
forwarding(3) - the port has returned to normal operation mode.
forwarding-trap(4) - the port has returned to normal operation mode. And
the device can send a broadcast falling trap."
::= { swPortCtrlEntry 15 }
swPortCtrlCleanAllStatisticCounter OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Setting this object will reset current device's all statistic counters."
::= { swPortCtrlEntry 16 }
-- ******************************************************
swPortStTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwPortStEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of port statistic Counter entries."
::= { swPortPackage 3 }
swPortStEntry OBJECT-TYPE
SYNTAX SwPortStEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry include all the port statistic Counter which support
by the device, like Bytes received, Bytes Sent ..."
INDEX { swPortStModuleIndex,swPortStPortIndex }
::= { swPortStTable 1 }
SwPortStEntry ::=
SEQUENCE {
swPortStModuleIndex
INTEGER,
swPortStPortIndex
INTEGER,
swPortStByteRx
Counter,
swPortStByteTx
Counter,
swPortStFrameRx
Counter,
swPortStFrameTx
Counter,
swPortStTotalBytesRx
Counter,
swPortStTotalFramesRx
Counter,
swPortStBroadcastFramesRx
Counter,
swPortStMulticastFramesRx
Counter,
swPortStCRCError
Counter,
swPortStOversizeFrames
Counter,
swPortStFragments
Counter,
swPortStJabber
Counter,
swPortStCollision
Counter,
swPortStLateCollision
Counter,
swPortStFrames-64-bytes
Counter,
swPortStFrames-65-127-bytes
Counter,
swPortStFrames-128-255-bytes
Counter,
swPortStFrames-256-511-bytes
Counter,
swPortStFrames-512-1023-bytes
Counter,
swPortStFrames-1024-1536-bytes
Counter,
swPortStFramesDroppedFrames
Counter,
swPortStMulticastFramesTx
Counter,
swPortStBroadcastFramesTx
Counter,
swPortStUndersizeFrames
Counter
}
swPortStModuleIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the device module number.(1..Max module number)"
::= { swPortStEntry 1 }
swPortStPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the module's port number.(1..Max port number in
the module)"
::= { swPortStEntry 2 }
swPortStByteRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"swDevCtrlCounterMode = 2(switched-frames):This counter is incre-
mented once for every data octet of good packets(unicast + multi-
cast + broadcast) received.
swDevCtrlCounterMode = 3(all-frames):This counter is incremented
once for every data octet of good packets(unicast + multicast +
broadcast packets) and for local and dropped packets."
::= { swPortStEntry 3 }
swPortStByteTx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every data octet of a trans-
mitted good packet."
::= { swPortStEntry 4 }
swPortStFrameRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"swDevCtrlCounterMode = 2(switched-frames):This counter is incre-
mented once for every good packet(unicast + multicast + broadcast
) received.
swDevCtrlCounterMode = 3(all-frames):This counter is incremented
once for every good packet(unicast + multicast + broadcast packets)
and for local and dropped packets received."
::= { swPortStEntry 5 }
swPortStFrameTx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every transmitted good packet."
::= { swPortStEntry 6 }
swPortStTotalBytesRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every data octet of all
received packets. This include data octets of rejected and local
packets which are not forwarded to the switching core for trans-
mission. This counter should reflect all the data octets received
on the line. Note: A nibble is not counted as a whole byte."
::= { swPortStEntry 7 }
swPortStTotalFramesRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every received packets. This
include rejected and local packets which are not forwarded to the
switching core for transmission. This counter should reflect all
packets received on the line."
::= { swPortStEntry 8 }
swPortStBroadcastFramesRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"swDevCtrlCounterMode = 2(switched-frames):This counter is incre-
mented once for every good broadcast packet received.
swDevCtrlCounterMode = 3(all-frames):This counter is incremented
once for every good broadcast packet received and for local and
dropped broadcast packets."
::= { swPortStEntry 9 }
swPortStMulticastFramesRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"swDevCtrlCounterMode = 2(switched-frames):This counter is incre-
mented once for every good multicast packet received.
swDevCtrlCounterMode = 3(all-frames):This counter is incremented
once for every good multicast packet received and for local and
dropped multicast packets. This counter does not include broad-
cast packets."
::= { swPortStEntry 10 }
swPortStCRCError OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every received packet which
meets all the following conditions:
1.Packet data length is between 64 and 1518 bytes inclusive.
2.Packet has invalid CRC.
3.Collision event , late collision event and receive error event
have not been detected."
::= { swPortStEntry 11 }
swPortStOversizeFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good frames with length more than 1518 bytes."
::= { swPortStEntry 12 }
swPortStFragments OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every received packet which
meets all the following conditions:
1.Packet data length is less than 64 bytes or packet withourt SFD
and is less than 64 bytes in length.
2.Packet has invalid CRC.
3.Collision event , late collision event and receive error event
have not been detected."
::= { swPortStEntry 13 }
swPortStJabber OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames with length more than 1518 bytes and with
CRC error or misaligned."
::= { swPortStEntry 14 }
swPortStCollision OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Collisions"
::= { swPortStEntry 15 }
swPortStLateCollision OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Late Collision(collision occurring later than
576th transmitted bit)."
::= { swPortStEntry 16 }
swPortStFrames-64-bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every received and trans-
mitted packet with size of 64 bytes. This counter includes reject-
ed received and transmitted packets."
::= { swPortStEntry 17 }
swPortStFrames-65-127-bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every received and trans-
mitted packet with size of 65 to 127 bytes. This counter includes
rejected received and transmitted packets."
::= { swPortStEntry 18 }
swPortStFrames-128-255-bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every received and trans-
mitted packet with size of 128 to 255 bytes. This counter includes
rejected received and transmitted packets."
::= { swPortStEntry 19 }
swPortStFrames-256-511-bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every received and trans-
mitted packet with size of 256 to 511 bytes. This counter includes
rejected received and transmitted packets."
::= { swPortStEntry 20 }
swPortStFrames-512-1023-bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every received and trans-
mitted packet with size of 512 to 1023 bytes. This counter includ-
es rejected received and transmitted packets."
::= { swPortStEntry 21 }
swPortStFrames-1024-1536-bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every received and trans-
mitted packet with size of 1024 to 1536 bytes. This counter includ-
es rejected received and transmitted packets."
::= { swPortStEntry 22 }
swPortStFramesDroppedFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every received dropped pack-
et."
::= { swPortStEntry 23 }
swPortStMulticastFramesTx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of multicast frames sent. This counter does not include
broadcast packets."
::= { swPortStEntry 24 }
swPortStBroadcastFramesTx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of broadcast frames sent."
::= { swPortStEntry 25 }
swPortStUndersizeFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented once for every received packet which
meets all the following conditions:
1.Packet data length is less than 64 bytes.
2.Packet has valid CRC.
3.Collision event , late collision event and receive error event
have not been detected."
::= { swPortStEntry 26 }
-- ********************************************************************
-- swFdbPackage OBJECT IDENTIFIER ::= { des3225gSeries 4 }
-- ********************************************************************
swFdbStaticTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwFdbStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Like typical legacy bridge devices, FDB table records the mapping
of Source MAC Address and its associated source port, and forward
incoming packets to its destination port according to the Destination
MAC Address of the packet as well as the MAC-port pair entries of the
FDB table. Note that the priority of FDB table entries is lower than
Filtering Table, i.e. if there is a table hash collision between the
entries of FDB Table and Filtering Table inside the switch H/W address
table, then Filtering Table entry overwrite the colliding entry of
FDB Table. See swFdbFilterTable description also."
::= { swFdbPackage 1 }
swFdbStaticEntry OBJECT-TYPE
SYNTAX SwFdbStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information specifies which ports the frames with specific
destination MAC address to go. "
INDEX { swFdbStaticVid , swFdbStaticAddressIndex }
::= { swFdbStaticTable 1 }
SwFdbStaticEntry ::=
SEQUENCE {
swFdbStaticVid
INTEGER,
swFdbStaticAddressIndex
MacAddress,
swFdbStaticPortMap
OCTET STRING,
swFdbStaticState
INTEGER,
swFdbStaticStatus
INTEGER
}
swFdbStaticVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the VLAN-ID. If VLAN is in mac-based
mode or disabled, the object indicates the default VLAN-ID (0)."
::= { swFdbStaticEntry 1 }
swFdbStaticAddressIndex OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The destination MAC address in a frame to which this entry's
forwarding information applies. This object can take the value of
an unicast address or the multicast address."
::= { swFdbStaticEntry 2 }
swFdbStaticPortMap OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The set of ports to which frames received from a specific port
and destined for a specific MAC address, are allowed to be
forwarded. Each octet within the value of this object specifies
a set of eight ports, with the first octet specifying ports 1
through 8, the second octet specifying ports 9 through 16, etc.
Within each octet, the most significant bit represents the lowest
numbered port, and the least significant bit represents the highest
numbered port. Thus, each port of the bridge is represented by
a single bit within the value of this object. If that bit has a
value of '1' then that port is included in the set of ports; the
port is not included if its bit has a value of '0'.(Note that the
setting of the bit corresponding to the port from which a frame
is received is irrelevant.). In module 1 (base module), there are
22 100M twisted-pair ports (port 1..22) which is mapped to the PortMap's
port 1 to 22 respectively. In module 2 (slot 1 module), there are 2 100M
FX/100 TX (or a single port 100M FX) ports which is mapped to the
PortMap's port 23, 24 respectively (if the module is a single port 100M FX
, it is just mapped to port 23 and port 24 is ignored). Module 3 (slot 2
module) is a single-port Gigabit Ethernet and it is mapped to the PortMap's
port 25."
::= { swFdbStaticEntry 3 }
swFdbStaticState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
valid(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the status of this entry.
other(1) - this entry is currently in use but the conditions under
which it will remain so are different from each of the following
values.
invalid(2) - writing this value to the object, and then the corresponding
entry will be removed from the table.
valid(3) - this entry is reside in the table."
::= { swFdbStaticEntry 4 }
swFdbStaticStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
apply(2),
not-apply(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the status of this entry.
other(1) - this entry is currently in use but the conditions under
which it will remain so are different from each of the following
values.
apply(2) - this entry is currently in use and reside in the table.
not-apply(3) - this entry is reside in the table but currently not
in use due to conflict with filter table."
::= { swFdbStaticEntry 5 }
swFdbFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwFdbFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table which contains the filtering information of the
unicast/multicast entries. This table is used by the transparent
switching function in determining how to filter the received frames.
The Filtering Table entries' priority overrides Static FDB Table
as well as IGMP table entries, say, if there is a hash table entry
collision between Filtering Table and Static FDB Table setting in
the switch device's H/W address table, then Filter Table entry setting
overwrites the colliding entry in Static FDB Table. See swFdbStaticTable
description also."
::= { swFdbPackage 2 }
swFdbFilterEntry OBJECT-TYPE
SYNTAX SwFdbFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information about a specific unicast/multicast MAC address
for which the switch has filtering information."
INDEX { swFdbFilterVid , swFdbFilterAddressIndex }
::= { swFdbFilterTable 1 }
SwFdbFilterEntry ::=
SEQUENCE {
swFdbFilterVid
INTEGER,
swFdbFilterAddressIndex
MacAddress,
swFdbFilterState
INTEGER
}
swFdbFilterVid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the VLAN-ID. If VLAN is in mac-based
mode or disabled, the object indicates the default VLAN-ID (0)."
::= { swFdbFilterEntry 1 }
swFdbFilterAddressIndex OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates a unicast/multicast MAC address for which the bridge
has filtering information."
::= { swFdbFilterEntry 2 }
swFdbFilterState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
dst-src-addr(2),
invalid(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the status of this entry.
other(1) - this entry is currently in use but the conditions under
which it will remain so are different from each of the following
values.
dst-src-addr(2) - recieved frames's destination address or source
address are currently used to be filtered as it meets with
the MAC address entry of the table.
invalid(3) - writing this value to the object, and then the corresponding
entry will be removed from the table."
::= { swFdbFilterEntry 3 }
portPartition TRAP-TYPE
ENTERPRISE swProperty
VARIABLES {
swPortInfoModuleIndex,swPortInfoPortIndex
}
DESCRIPTION
"The trap is sent whenever the port state enter the
Partion mode when more than 61 collisions occur while
trasmitting."
::=1
linkChangeEvent TRAP-TYPE
ENTERPRISE swProperty
VARIABLES {
swPortInfoModuleIndex,swPortInfoPortIndex
}
DESCRIPTION
"The trap is sent whenever the link state of a port changes
from link up to link down or from link down to link up"
::= 2
broadcastRisingStorm TRAP-TYPE
ENTERPRISE swProperty
VARIABLES {
swPortInfoModuleIndex,swPortInfoPortIndex
}
DESCRIPTION
"The trap indicates that broadcast higher rising threshold
. This trap including the port ID"
::= 3
broadcastFallingStorm TRAP-TYPE
ENTERPRISE swProperty
VARIABLES {
swPortInfoModuleIndex,swPortInfoPortIndex
}
DESCRIPTION
"The trap indicates that broadcast higher falling threshold
. This trap including the port ID"
::= 4
END