-- PTP-MIB: ME1200 Private MIB
|
|
--
|
|
--
|
|
-- ****************************************************************
|
|
|
|
ME1200-PTP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
me1200SwitchMgmt
|
|
FROM CISCOME1200-MIB
|
|
ME1200Integer16 FROM ME1200-TC
|
|
ME1200Integer64 FROM ME1200-TC
|
|
ME1200InterfaceIndex FROM ME1200-TC
|
|
ME1200RowEditorState FROM ME1200-TC
|
|
ME1200Unsigned16 FROM ME1200-TC
|
|
ME1200Unsigned64 FROM ME1200-TC
|
|
ME1200Unsigned8 FROM ME1200-TC
|
|
Integer32 FROM SNMPv2-SMI
|
|
IpAddress FROM SNMPv2-SMI
|
|
Unsigned32 FROM SNMPv2-SMI
|
|
MacAddress FROM SNMPv2-TC
|
|
TruthValue FROM SNMPv2-TC
|
|
;
|
|
|
|
me1200PtpMib MODULE-IDENTITY
|
|
LAST-UPDATED "201507060000Z"
|
|
ORGANIZATION
|
|
"Cisco Systems, Inc"
|
|
CONTACT-INFO
|
|
"Cisco Systems, Inc
|
|
Customer Service
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
Tel: +1 800 553-NETS
|
|
E-mail: cs-me1200@cisco.com"
|
|
DESCRIPTION
|
|
"Private PTP MIB."
|
|
REVISION "201507060000Z"
|
|
DESCRIPTION
|
|
"Added hardware clock domain, support for profiles and fields related to
|
|
8275.1"
|
|
REVISION "201503260000Z"
|
|
DESCRIPTION
|
|
"Added attribute Dscp to PtpConfigClocksDefaultDs"
|
|
REVISION "201404140000Z"
|
|
DESCRIPTION
|
|
"Initial version"
|
|
::= { me1200SwitchMgmt 65 }
|
|
|
|
|
|
ME1200ptpClockPortState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { initializing(0), faulty(1), disabled(2), listening(3), preMaster(4), master(5), passive(6), uncalibrated(7), slave(8), p2pTransparent(9), e2eTransparent(10) }
|
|
|
|
ME1200ptpDestAdrType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { default(0), linkLocal(1) }
|
|
|
|
ME1200ptpDeviceType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { none(0), ordBound(1), p2pTransparent(2), e2eTransparent(3), masterOnly(4), slaveOnly(5) }
|
|
|
|
ME1200ptpExtClock1pps ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { onePpsDisable(0), onePpsOutput(1), onePpsInput(2) }
|
|
|
|
ME1200ptpPreferredAdj ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { preferredAdjLtc(0), preferredAdjSyncE(1), preferredAdjXO(2), preferredAdjLtcPhase(3) }
|
|
|
|
ME1200ptpProfile ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { noProfile(0), ieee1588(1), g8265(2), g8275(3) }
|
|
|
|
ME1200ptpProtocol ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { ethernet(0), ethernetMixed(1), ip4multi(2), ip4mixed(3), ip4uni(4), oam(5), onePps(6) }
|
|
|
|
ME1200ptpServoClockOption ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { clockFree(0), clockSyncE(1) }
|
|
|
|
ME1200ptpSlaveClockState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { slaveClockStateFreerun(0), slaveClockStateFreqLocking(1), slaveClockStatePhaseLocking(2), slaveClockStateLocked(3), slaveClockStateHoldover(4), slaveClockStateInvalid(5) }
|
|
|
|
ME1200ptpSystemTimeSyncMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { systemTimeNoSync(0), systemTimeSyncGet(1), systemTimeSyncSet(2) }
|
|
|
|
ME1200ptpUcCommState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { idle(0), initializing(1), connected(2), selected(3), synced(4) }
|
|
|
|
me1200PtpMibObjects OBJECT IDENTIFIER
|
|
::= { me1200PtpMib 1 }
|
|
|
|
me1200PtpCapabilities OBJECT IDENTIFIER
|
|
::= { me1200PtpMibObjects 1 }
|
|
|
|
me1200PtpCapabilitiesGlobals OBJECT IDENTIFIER
|
|
::= { me1200PtpCapabilities 1 }
|
|
|
|
me1200PtpCapabilitiesGlobalsClockCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of PTP clocks supported by the device."
|
|
::= { me1200PtpCapabilitiesGlobals 1 }
|
|
|
|
me1200PtpConfig OBJECT IDENTIFIER
|
|
::= { me1200PtpMibObjects 2 }
|
|
|
|
me1200PtpConfigGlobals OBJECT IDENTIFIER
|
|
::= { me1200PtpConfig 1 }
|
|
|
|
me1200PtpConfigGlobalsExternalClockMode OBJECT IDENTIFIER
|
|
::= { me1200PtpConfigGlobals 1 }
|
|
|
|
me1200PtpConfigGlobalsExternalClockModeOnePpsMode OBJECT-TYPE
|
|
SYNTAX ME1200ptpExtClock1pps
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The mode of the PPS pin."
|
|
::= { me1200PtpConfigGlobalsExternalClockMode 1 }
|
|
|
|
me1200PtpConfigGlobalsExternalClockModeExternalEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"External enable of PPS output."
|
|
::= { me1200PtpConfigGlobalsExternalClockMode 2 }
|
|
|
|
me1200PtpConfigGlobalsExternalClockModeAdjustMethod OBJECT-TYPE
|
|
SYNTAX ME1200ptpPreferredAdj
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The adjustment method of the PPS external output.
|
|
|
|
0: LTC Frequency
|
|
|
|
1: SyncE DPLL
|
|
|
|
2: Oscillator
|
|
|
|
3: LTC Phase"
|
|
::= { me1200PtpConfigGlobalsExternalClockMode 3 }
|
|
|
|
me1200PtpConfigGlobalsExternalClockModeClockFrequency OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The frequency in hertz (Hz) of the PPS external output."
|
|
::= { me1200PtpConfigGlobalsExternalClockMode 4 }
|
|
|
|
me1200PtpConfigGlobalsSystemTimeSyncMode OBJECT IDENTIFIER
|
|
::= { me1200PtpConfigGlobals 2 }
|
|
|
|
me1200PtpConfigGlobalsSystemTimeSyncModeMode OBJECT-TYPE
|
|
SYNTAX ME1200ptpSystemTimeSyncMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mode of the System time <-> ptp time synchronization."
|
|
::= { me1200PtpConfigGlobalsSystemTimeSyncMode 1 }
|
|
|
|
me1200PtpConfigClocks OBJECT IDENTIFIER
|
|
::= { me1200PtpConfig 2 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpConfigClocksDefaultDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the configurable part of the PTP clocks DefaultDS."
|
|
::= { me1200PtpConfigClocks 1 }
|
|
|
|
me1200PtpConfigClocksDefaultDsEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpConfigClocksDefaultDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpConfigClocksDefaultDsClockId }
|
|
::= { me1200PtpConfigClocksDefaultDsTable 1 }
|
|
|
|
ME1200PtpConfigClocksDefaultDsEntry ::= SEQUENCE {
|
|
me1200PtpConfigClocksDefaultDsClockId Integer32,
|
|
me1200PtpConfigClocksDefaultDsDeviceType ME1200ptpDeviceType,
|
|
me1200PtpConfigClocksDefaultDsTwoStepFlag TruthValue,
|
|
me1200PtpConfigClocksDefaultDsPriority1 ME1200Unsigned8,
|
|
me1200PtpConfigClocksDefaultDsPriority2 ME1200Unsigned8,
|
|
me1200PtpConfigClocksDefaultDsOneWay TruthValue,
|
|
me1200PtpConfigClocksDefaultDsDomainNumber ME1200Unsigned8,
|
|
me1200PtpConfigClocksDefaultDsProtocol ME1200ptpProtocol,
|
|
me1200PtpConfigClocksDefaultDsVlanTagEnable TruthValue,
|
|
me1200PtpConfigClocksDefaultDsVid ME1200Unsigned16,
|
|
me1200PtpConfigClocksDefaultDsPcp ME1200Unsigned8,
|
|
me1200PtpConfigClocksDefaultDsMep Integer32,
|
|
me1200PtpConfigClocksDefaultDsClkDom Unsigned32,
|
|
me1200PtpConfigClocksDefaultDsDscp ME1200Unsigned8,
|
|
me1200PtpConfigClocksDefaultDsProfile ME1200ptpProfile,
|
|
me1200PtpConfigClocksDefaultDsLocalPriority ME1200Unsigned8,
|
|
me1200PtpConfigClocksDefaultDsAction ME1200RowEditorState
|
|
}
|
|
|
|
me1200PtpConfigClocksDefaultDsClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 1 }
|
|
|
|
me1200PtpConfigClocksDefaultDsDeviceType OBJECT-TYPE
|
|
SYNTAX ME1200ptpDeviceType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PTP clock type."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 2 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTwoStepFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines whether clock uses follow-up packets."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 3 }
|
|
|
|
me1200PtpConfigClocksDefaultDsPriority1 OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority1 value."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 4 }
|
|
|
|
me1200PtpConfigClocksDefaultDsPriority2 OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority2 value."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 5 }
|
|
|
|
me1200PtpConfigClocksDefaultDsOneWay OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines whether clock uses sync packets only."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 6 }
|
|
|
|
me1200PtpConfigClocksDefaultDsDomainNumber OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The domain number."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 7 }
|
|
|
|
me1200PtpConfigClocksDefaultDsProtocol OBJECT-TYPE
|
|
SYNTAX ME1200ptpProtocol
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The protocol to be used for the encapsulation of the PTP packets."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 8 }
|
|
|
|
me1200PtpConfigClocksDefaultDsVlanTagEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines whether clock uses sync packets only."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 9 }
|
|
|
|
me1200PtpConfigClocksDefaultDsVid OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VLAN id (if VLAN tagging is enabled)."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 10 }
|
|
|
|
me1200PtpConfigClocksDefaultDsPcp OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PCP value (if VLAN tagging is enabled)."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 11 }
|
|
|
|
me1200PtpConfigClocksDefaultDsMep OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The mep instance number (if protocol is OAM)."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 12 }
|
|
|
|
me1200PtpConfigClocksDefaultDsClkDom OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock domain used."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 13 }
|
|
|
|
me1200PtpConfigClocksDefaultDsDscp OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP field value (if protocol is IPv4)."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 14 }
|
|
|
|
me1200PtpConfigClocksDefaultDsProfile OBJECT-TYPE
|
|
SYNTAX ME1200ptpProfile
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PTP profile."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 15 }
|
|
|
|
me1200PtpConfigClocksDefaultDsLocalPriority OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local priority value."
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 16 }
|
|
|
|
me1200PtpConfigClocksDefaultDsAction OBJECT-TYPE
|
|
SYNTAX ME1200RowEditorState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action"
|
|
::= { me1200PtpConfigClocksDefaultDsEntry 100 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditor OBJECT IDENTIFIER
|
|
::= { me1200PtpConfigClocks 2 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 1 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorDeviceType OBJECT-TYPE
|
|
SYNTAX ME1200ptpDeviceType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PTP clock type."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 2 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorTwoStepFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines whether clock uses follow-up packets."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 3 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorPriority1 OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority1 value."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 4 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorPriority2 OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority2 value."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 5 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorOneWay OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines whether clock uses sync packets only."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 6 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorDomainNumber OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The domain number."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 7 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorProtocol OBJECT-TYPE
|
|
SYNTAX ME1200ptpProtocol
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The protocol to be used for the encapsulation of the PTP packets."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 8 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorVlanTagEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines whether clock uses sync packets only."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 9 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorVid OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VLAN id (if VLAN tagging is enabled)."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 10 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorPcp OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PCP value (if VLAN tagging is enabled)."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 11 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorMep OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The mep instance number (if protocol is OAM)."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 12 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorClkDom OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock domain used."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 13 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorDscp OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSCP field value (if protocol is IPv4)."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 14 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorProfile OBJECT-TYPE
|
|
SYNTAX ME1200ptpProfile
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PTP profile."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 15 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorLocalPriority OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local priority value."
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 16 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorAction OBJECT-TYPE
|
|
SYNTAX ME1200RowEditorState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action"
|
|
::= { me1200PtpConfigClocksDefaultDsTableRowEditor 100 }
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpConfigClocksTimePropertiesDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the configurable part of the PTP clocks TimePropertiesDS."
|
|
::= { me1200PtpConfigClocks 3 }
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpConfigClocksTimePropertiesDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpConfigClocksTimePropertiesDsClockId }
|
|
::= { me1200PtpConfigClocksTimePropertiesDsTable 1 }
|
|
|
|
ME1200PtpConfigClocksTimePropertiesDsEntry ::= SEQUENCE {
|
|
me1200PtpConfigClocksTimePropertiesDsClockId Integer32,
|
|
me1200PtpConfigClocksTimePropertiesDsCurrentUtcOffset ME1200Integer16,
|
|
me1200PtpConfigClocksTimePropertiesDsCurrentUtcOffsetValid TruthValue,
|
|
me1200PtpConfigClocksTimePropertiesDsLeap59 TruthValue,
|
|
me1200PtpConfigClocksTimePropertiesDsLeap61 TruthValue,
|
|
me1200PtpConfigClocksTimePropertiesDsTimeTraceable TruthValue,
|
|
me1200PtpConfigClocksTimePropertiesDsFrequencyTraceable TruthValue,
|
|
me1200PtpConfigClocksTimePropertiesDsPtpTimescale TruthValue,
|
|
me1200PtpConfigClocksTimePropertiesDsTimeSource ME1200Unsigned8
|
|
}
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpConfigClocksTimePropertiesDsEntry 1 }
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsCurrentUtcOffset OBJECT-TYPE
|
|
SYNTAX ME1200Integer16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current UTC time offset."
|
|
::= { me1200PtpConfigClocksTimePropertiesDsEntry 2 }
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsCurrentUtcOffsetValid OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the current UTC time offset value is valid."
|
|
::= { me1200PtpConfigClocksTimePropertiesDsEntry 3 }
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsLeap59 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the last minute of the day has only 59 seconds."
|
|
::= { me1200PtpConfigClocksTimePropertiesDsEntry 4 }
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsLeap61 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the last minute of the day has 61 seconds."
|
|
::= { me1200PtpConfigClocksTimePropertiesDsEntry 5 }
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsTimeTraceable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that time is traceable to a primary reference."
|
|
::= { me1200PtpConfigClocksTimePropertiesDsEntry 6 }
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsFrequencyTraceable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that frequency is traceable to a primary reference."
|
|
::= { me1200PtpConfigClocksTimePropertiesDsEntry 7 }
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsPtpTimescale OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether timescale of the grandmaster clock is PTP."
|
|
::= { me1200PtpConfigClocksTimePropertiesDsEntry 8 }
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsTimeSource OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Source of time used by the grandmaster clock."
|
|
::= { me1200PtpConfigClocksTimePropertiesDsEntry 9 }
|
|
|
|
me1200PtpConfigClocksFilterParametersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpConfigClocksFilterParametersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the configurable part of the PTP clocks filter parameters."
|
|
::= { me1200PtpConfigClocks 4 }
|
|
|
|
me1200PtpConfigClocksFilterParametersEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpConfigClocksFilterParametersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpConfigClocksFilterParametersClockId }
|
|
::= { me1200PtpConfigClocksFilterParametersTable 1 }
|
|
|
|
ME1200PtpConfigClocksFilterParametersEntry ::= SEQUENCE {
|
|
me1200PtpConfigClocksFilterParametersClockId Integer32,
|
|
me1200PtpConfigClocksFilterParametersDelayFilter Unsigned32,
|
|
me1200PtpConfigClocksFilterParametersFilterType Unsigned32,
|
|
me1200PtpConfigClocksFilterParametersPeriod Unsigned32,
|
|
me1200PtpConfigClocksFilterParametersDist Unsigned32
|
|
}
|
|
|
|
me1200PtpConfigClocksFilterParametersClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpConfigClocksFilterParametersEntry 1 }
|
|
|
|
me1200PtpConfigClocksFilterParametersDelayFilter OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the time constant of the delay filter."
|
|
::= { me1200PtpConfigClocksFilterParametersEntry 2 }
|
|
|
|
me1200PtpConfigClocksFilterParametersFilterType OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects the type of filter/servo used."
|
|
::= { me1200PtpConfigClocksFilterParametersEntry 3 }
|
|
|
|
me1200PtpConfigClocksFilterParametersPeriod OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the period of the offset filter."
|
|
::= { me1200PtpConfigClocksFilterParametersEntry 4 }
|
|
|
|
me1200PtpConfigClocksFilterParametersDist OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the dist value of the offset filter."
|
|
::= { me1200PtpConfigClocksFilterParametersEntry 5 }
|
|
|
|
me1200PtpConfigClocksServoParametersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpConfigClocksServoParametersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the configurable part of the PTP clocks servo parameters."
|
|
::= { me1200PtpConfigClocks 5 }
|
|
|
|
me1200PtpConfigClocksServoParametersEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpConfigClocksServoParametersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpConfigClocksServoParametersClockId }
|
|
::= { me1200PtpConfigClocksServoParametersTable 1 }
|
|
|
|
ME1200PtpConfigClocksServoParametersEntry ::= SEQUENCE {
|
|
me1200PtpConfigClocksServoParametersClockId Integer32,
|
|
me1200PtpConfigClocksServoParametersDisplay TruthValue,
|
|
me1200PtpConfigClocksServoParametersPEnable TruthValue,
|
|
me1200PtpConfigClocksServoParametersIEnable TruthValue,
|
|
me1200PtpConfigClocksServoParametersDEnable TruthValue,
|
|
me1200PtpConfigClocksServoParametersPval Unsigned32,
|
|
me1200PtpConfigClocksServoParametersIval Unsigned32,
|
|
me1200PtpConfigClocksServoParametersDval Unsigned32,
|
|
me1200PtpConfigClocksServoParametersSrvOption ME1200ptpServoClockOption,
|
|
me1200PtpConfigClocksServoParametersSynceThreshold Unsigned32,
|
|
me1200PtpConfigClocksServoParametersSynceAp Unsigned32,
|
|
me1200PtpConfigClocksServoParametersHoFilter Integer32,
|
|
me1200PtpConfigClocksServoParametersStableAdjThreshold ME1200Unsigned64
|
|
}
|
|
|
|
me1200PtpConfigClocksServoParametersClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpConfigClocksServoParametersEntry 1 }
|
|
|
|
me1200PtpConfigClocksServoParametersDisplay OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether output shall be sent to the debug terminal."
|
|
::= { me1200PtpConfigClocksServoParametersEntry 2 }
|
|
|
|
me1200PtpConfigClocksServoParametersPEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether P-value of servo algorithm shall be used."
|
|
::= { me1200PtpConfigClocksServoParametersEntry 3 }
|
|
|
|
me1200PtpConfigClocksServoParametersIEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether I-value of servo algorithm shall be used."
|
|
::= { me1200PtpConfigClocksServoParametersEntry 4 }
|
|
|
|
me1200PtpConfigClocksServoParametersDEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether D-value of servo algorithm shall be used."
|
|
::= { me1200PtpConfigClocksServoParametersEntry 5 }
|
|
|
|
me1200PtpConfigClocksServoParametersPval OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"P-value of the offset filter."
|
|
::= { me1200PtpConfigClocksServoParametersEntry 6 }
|
|
|
|
me1200PtpConfigClocksServoParametersIval OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"I-value of the offset filter."
|
|
::= { me1200PtpConfigClocksServoParametersEntry 7 }
|
|
|
|
me1200PtpConfigClocksServoParametersDval OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"D-value of the offset filter."
|
|
::= { me1200PtpConfigClocksServoParametersEntry 8 }
|
|
|
|
me1200PtpConfigClocksServoParametersSrvOption OBJECT-TYPE
|
|
SYNTAX ME1200ptpServoClockOption
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"D-value of the offset filter."
|
|
::= { me1200PtpConfigClocksServoParametersEntry 9 }
|
|
|
|
me1200PtpConfigClocksServoParametersSynceThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SyncE Threshold"
|
|
::= { me1200PtpConfigClocksServoParametersEntry 10 }
|
|
|
|
me1200PtpConfigClocksServoParametersSynceAp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SyncE Ap"
|
|
::= { me1200PtpConfigClocksServoParametersEntry 11 }
|
|
|
|
me1200PtpConfigClocksServoParametersHoFilter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Holdoff low pass filter constant."
|
|
::= { me1200PtpConfigClocksServoParametersEntry 12 }
|
|
|
|
me1200PtpConfigClocksServoParametersStableAdjThreshold OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned64
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Threshold at which offset is assumed to be stable."
|
|
::= { me1200PtpConfigClocksServoParametersEntry 13 }
|
|
|
|
me1200PtpConfigClocksSlaveConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpConfigClocksSlaveConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the configurable part of the PTP clocks slave configuration."
|
|
::= { me1200PtpConfigClocks 6 }
|
|
|
|
me1200PtpConfigClocksSlaveConfigEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpConfigClocksSlaveConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpConfigClocksSlaveConfigClockId }
|
|
::= { me1200PtpConfigClocksSlaveConfigTable 1 }
|
|
|
|
ME1200PtpConfigClocksSlaveConfigEntry ::= SEQUENCE {
|
|
me1200PtpConfigClocksSlaveConfigClockId Integer32,
|
|
me1200PtpConfigClocksSlaveConfigStableOffset Unsigned32,
|
|
me1200PtpConfigClocksSlaveConfigOffsetOk Unsigned32,
|
|
me1200PtpConfigClocksSlaveConfigOffsetFail Unsigned32
|
|
}
|
|
|
|
me1200PtpConfigClocksSlaveConfigClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpConfigClocksSlaveConfigEntry 1 }
|
|
|
|
me1200PtpConfigClocksSlaveConfigStableOffset OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Stable offset threshold in ns."
|
|
::= { me1200PtpConfigClocksSlaveConfigEntry 2 }
|
|
|
|
me1200PtpConfigClocksSlaveConfigOffsetOk OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Offset OK threshold in ns."
|
|
::= { me1200PtpConfigClocksSlaveConfigEntry 3 }
|
|
|
|
me1200PtpConfigClocksSlaveConfigOffsetFail OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Offset fail threshold in ns."
|
|
::= { me1200PtpConfigClocksSlaveConfigEntry 4 }
|
|
|
|
me1200PtpConfigClocksUnicastSlaveConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpConfigClocksUnicastSlaveConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the configurable part of the PTP clocks unicast slave
|
|
configuration."
|
|
::= { me1200PtpConfigClocks 7 }
|
|
|
|
me1200PtpConfigClocksUnicastSlaveConfigEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpConfigClocksUnicastSlaveConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpConfigClocksUnicastSlaveConfigClockId, me1200PtpConfigClocksUnicastSlaveConfigMasterId }
|
|
::= { me1200PtpConfigClocksUnicastSlaveConfigTable 1 }
|
|
|
|
ME1200PtpConfigClocksUnicastSlaveConfigEntry ::= SEQUENCE {
|
|
me1200PtpConfigClocksUnicastSlaveConfigClockId Integer32,
|
|
me1200PtpConfigClocksUnicastSlaveConfigMasterId Integer32,
|
|
me1200PtpConfigClocksUnicastSlaveConfigDuration Unsigned32,
|
|
me1200PtpConfigClocksUnicastSlaveConfigIpAddress IpAddress
|
|
}
|
|
|
|
me1200PtpConfigClocksUnicastSlaveConfigClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpConfigClocksUnicastSlaveConfigEntry 1 }
|
|
|
|
me1200PtpConfigClocksUnicastSlaveConfigMasterId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpConfigClocksUnicastSlaveConfigEntry 2 }
|
|
|
|
me1200PtpConfigClocksUnicastSlaveConfigDuration OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds for which the Announce/Sync messages are requested."
|
|
::= { me1200PtpConfigClocksUnicastSlaveConfigEntry 3 }
|
|
|
|
me1200PtpConfigClocksUnicastSlaveConfigIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv4 address of requested master clock."
|
|
::= { me1200PtpConfigClocksUnicastSlaveConfigEntry 4 }
|
|
|
|
me1200PtpConfigClocksPortDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpConfigClocksPortDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the configurable part of the PTP clocks PortDS."
|
|
::= { me1200PtpConfigClocks 8 }
|
|
|
|
me1200PtpConfigClocksPortDsEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpConfigClocksPortDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpConfigClocksPortDsClockId, me1200PtpConfigClocksPortDsPortId }
|
|
::= { me1200PtpConfigClocksPortDsTable 1 }
|
|
|
|
ME1200PtpConfigClocksPortDsEntry ::= SEQUENCE {
|
|
me1200PtpConfigClocksPortDsClockId Integer32,
|
|
me1200PtpConfigClocksPortDsPortId ME1200InterfaceIndex,
|
|
me1200PtpConfigClocksPortDsEnabled ME1200Unsigned8,
|
|
me1200PtpConfigClocksPortDsLogAnnounceInterval ME1200Integer16,
|
|
me1200PtpConfigClocksPortDsAnnounceReceiptTimeout ME1200Unsigned8,
|
|
me1200PtpConfigClocksPortDsLogSyncInterval ME1200Integer16,
|
|
me1200PtpConfigClocksPortDsDelayMechanism ME1200Unsigned8,
|
|
me1200PtpConfigClocksPortDsLogMinPdelayReqInterval ME1200Integer16,
|
|
me1200PtpConfigClocksPortDsDelayAsymmetry ME1200Integer64,
|
|
me1200PtpConfigClocksPortDsIngressLatency ME1200Integer64,
|
|
me1200PtpConfigClocksPortDsEgressLatency ME1200Integer64,
|
|
me1200PtpConfigClocksPortDsPortInternal TruthValue,
|
|
me1200PtpConfigClocksPortDsVersionNumber ME1200Unsigned16,
|
|
me1200PtpConfigClocksPortDsMcastAddr ME1200ptpDestAdrType,
|
|
me1200PtpConfigClocksPortDsNotSlave TruthValue,
|
|
me1200PtpConfigClocksPortDsLocalPriority ME1200Unsigned8
|
|
}
|
|
|
|
me1200PtpConfigClocksPortDsClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpConfigClocksPortDsEntry 1 }
|
|
|
|
me1200PtpConfigClocksPortDsPortId OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpConfigClocksPortDsEntry 2 }
|
|
|
|
me1200PtpConfigClocksPortDsEnabled OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines whether port is enabled."
|
|
::= { me1200PtpConfigClocksPortDsEntry 3 }
|
|
|
|
me1200PtpConfigClocksPortDsLogAnnounceInterval OBJECT-TYPE
|
|
SYNTAX ME1200Integer16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interval between announce message transmissions."
|
|
::= { me1200PtpConfigClocksPortDsEntry 4 }
|
|
|
|
me1200PtpConfigClocksPortDsAnnounceReceiptTimeout OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timeout for receiving announce messages on the port."
|
|
::= { me1200PtpConfigClocksPortDsEntry 5 }
|
|
|
|
me1200PtpConfigClocksPortDsLogSyncInterval OBJECT-TYPE
|
|
SYNTAX ME1200Integer16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interval for issuing sync meesages in the master."
|
|
::= { me1200PtpConfigClocksPortDsEntry 6 }
|
|
|
|
me1200PtpConfigClocksPortDsDelayMechanism OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay mechanism used for the port."
|
|
::= { me1200PtpConfigClocksPortDsEntry 7 }
|
|
|
|
me1200PtpConfigClocksPortDsLogMinPdelayReqInterval OBJECT-TYPE
|
|
SYNTAX ME1200Integer16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of logMinPdelayReqInterval"
|
|
::= { me1200PtpConfigClocksPortDsEntry 8 }
|
|
|
|
me1200PtpConfigClocksPortDsDelayAsymmetry OBJECT-TYPE
|
|
SYNTAX ME1200Integer64
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the communication path asymmetry."
|
|
::= { me1200PtpConfigClocksPortDsEntry 9 }
|
|
|
|
me1200PtpConfigClocksPortDsIngressLatency OBJECT-TYPE
|
|
SYNTAX ME1200Integer64
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ingress delay for port."
|
|
::= { me1200PtpConfigClocksPortDsEntry 10 }
|
|
|
|
me1200PtpConfigClocksPortDsEgressLatency OBJECT-TYPE
|
|
SYNTAX ME1200Integer64
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Egress delay for port."
|
|
::= { me1200PtpConfigClocksPortDsEntry 11 }
|
|
|
|
me1200PtpConfigClocksPortDsPortInternal OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines whether port is enabled as an internal interface."
|
|
::= { me1200PtpConfigClocksPortDsEntry 12 }
|
|
|
|
me1200PtpConfigClocksPortDsVersionNumber OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of PTP being used by the port."
|
|
::= { me1200PtpConfigClocksPortDsEntry 13 }
|
|
|
|
me1200PtpConfigClocksPortDsMcastAddr OBJECT-TYPE
|
|
SYNTAX ME1200ptpDestAdrType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The multicast address used (default or link local)."
|
|
::= { me1200PtpConfigClocksPortDsEntry 14 }
|
|
|
|
me1200PtpConfigClocksPortDsNotSlave OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When true, the port will not act as a slave."
|
|
::= { me1200PtpConfigClocksPortDsEntry 15 }
|
|
|
|
me1200PtpConfigClocksPortDsLocalPriority OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local priority value."
|
|
::= { me1200PtpConfigClocksPortDsEntry 16 }
|
|
|
|
me1200PtpStatus OBJECT IDENTIFIER
|
|
::= { me1200PtpMibObjects 3 }
|
|
|
|
me1200PtpStatusClocks OBJECT IDENTIFIER
|
|
::= { me1200PtpStatus 1 }
|
|
|
|
me1200PtpStatusClocksDefaultDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpStatusClocksDefaultDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the dynamic (status) part of the PTP clocks DefaultDS."
|
|
::= { me1200PtpStatusClocks 1 }
|
|
|
|
me1200PtpStatusClocksDefaultDsEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpStatusClocksDefaultDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpStatusClocksDefaultDsClockId }
|
|
::= { me1200PtpStatusClocksDefaultDsTable 1 }
|
|
|
|
ME1200PtpStatusClocksDefaultDsEntry ::= SEQUENCE {
|
|
me1200PtpStatusClocksDefaultDsClockId Integer32,
|
|
me1200PtpStatusClocksDefaultDsClockIdentity OCTET STRING,
|
|
me1200PtpStatusClocksDefaultDsClockQualityClockClass ME1200Unsigned8,
|
|
me1200PtpStatusClocksDefaultDsClockQualityClockAccuracy ME1200Unsigned8,
|
|
me1200PtpStatusClocksDefaultDsClockQualityOffsetScaledLogVar ME1200Unsigned16
|
|
}
|
|
|
|
me1200PtpStatusClocksDefaultDsClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksDefaultDsEntry 1 }
|
|
|
|
me1200PtpStatusClocksDefaultDsClockIdentity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the unique 8 byte clockIdentify field from the DefaultDS
|
|
structure."
|
|
::= { me1200PtpStatusClocksDefaultDsEntry 2 }
|
|
|
|
me1200PtpStatusClocksDefaultDsClockQualityClockClass OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock class field of the clock quality structure."
|
|
::= { me1200PtpStatusClocksDefaultDsEntry 3 }
|
|
|
|
me1200PtpStatusClocksDefaultDsClockQualityClockAccuracy OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock accuracy field of the clock quality structure."
|
|
::= { me1200PtpStatusClocksDefaultDsEntry 4 }
|
|
|
|
me1200PtpStatusClocksDefaultDsClockQualityOffsetScaledLogVar OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the offsetScaledLogVariance field of the clock quality
|
|
structure."
|
|
::= { me1200PtpStatusClocksDefaultDsEntry 5 }
|
|
|
|
me1200PtpStatusClocksCurrentDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpStatusClocksCurrentDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the dynamic (status) part of the PTP clocks CurrentDS."
|
|
::= { me1200PtpStatusClocks 2 }
|
|
|
|
me1200PtpStatusClocksCurrentDsEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpStatusClocksCurrentDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpStatusClocksCurrentDsClockId }
|
|
::= { me1200PtpStatusClocksCurrentDsTable 1 }
|
|
|
|
ME1200PtpStatusClocksCurrentDsEntry ::= SEQUENCE {
|
|
me1200PtpStatusClocksCurrentDsClockId Integer32,
|
|
me1200PtpStatusClocksCurrentDsStepsRemoved ME1200Unsigned16,
|
|
me1200PtpStatusClocksCurrentDsOffsetFromMaster ME1200Integer64,
|
|
me1200PtpStatusClocksCurrentDsMeanPathDelay ME1200Integer64
|
|
}
|
|
|
|
me1200PtpStatusClocksCurrentDsClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksCurrentDsEntry 1 }
|
|
|
|
me1200PtpStatusClocksCurrentDsStepsRemoved OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of PTP clocks traversed from the grandmaster to the local
|
|
PTP clock."
|
|
::= { me1200PtpStatusClocksCurrentDsEntry 2 }
|
|
|
|
me1200PtpStatusClocksCurrentDsOffsetFromMaster OBJECT-TYPE
|
|
SYNTAX ME1200Integer64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time differece in ns from the grandmaster to the local PTP clock."
|
|
::= { me1200PtpStatusClocksCurrentDsEntry 3 }
|
|
|
|
me1200PtpStatusClocksCurrentDsMeanPathDelay OBJECT-TYPE
|
|
SYNTAX ME1200Integer64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The mean path delay from the master to the local slave."
|
|
::= { me1200PtpStatusClocksCurrentDsEntry 4 }
|
|
|
|
me1200PtpStatusClocksParentDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpStatusClocksParentDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the dynamic (status) part of the PTP clocks ParentDS."
|
|
::= { me1200PtpStatusClocks 3 }
|
|
|
|
me1200PtpStatusClocksParentDsEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpStatusClocksParentDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpStatusClocksParentDsClockId }
|
|
::= { me1200PtpStatusClocksParentDsTable 1 }
|
|
|
|
ME1200PtpStatusClocksParentDsEntry ::= SEQUENCE {
|
|
me1200PtpStatusClocksParentDsClockId Integer32,
|
|
me1200PtpStatusClocksParentDsParentPortIdentityClockIdentity OCTET STRING,
|
|
me1200PtpStatusClocksParentDsParentPortIdentityPortNumber ME1200Unsigned16,
|
|
me1200PtpStatusClocksParentDsParentStats TruthValue,
|
|
me1200PtpStatusClocksParentDsObservedParentOffsetScaledLogVar ME1200Unsigned16,
|
|
me1200PtpStatusClocksParentDsObservedParentClockPhaseChangeRate Integer32,
|
|
me1200PtpStatusClocksParentDsGrmstrIdentity OCTET STRING,
|
|
me1200PtpStatusClocksParentDsGrmstrClkQualClockClass ME1200Unsigned8,
|
|
me1200PtpStatusClocksParentDsGmstrClkQualClockAccuracy ME1200Unsigned8,
|
|
me1200PtpStatusClocksParentDsGmstrClkQualOffsetScaledLogVar ME1200Unsigned16,
|
|
me1200PtpStatusClocksParentDsGmstrPriority1 ME1200Unsigned8,
|
|
me1200PtpStatusClocksParentDsGmstrPriority2 ME1200Unsigned8
|
|
}
|
|
|
|
me1200PtpStatusClocksParentDsClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksParentDsEntry 1 }
|
|
|
|
me1200PtpStatusClocksParentDsParentPortIdentityClockIdentity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the 8 byte unique clock identity of the parent port."
|
|
::= { me1200PtpStatusClocksParentDsEntry 2 }
|
|
|
|
me1200PtpStatusClocksParentDsParentPortIdentityPortNumber OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the port number on the parent associated with the parent clock."
|
|
::= { me1200PtpStatusClocksParentDsEntry 3 }
|
|
|
|
me1200PtpStatusClocksParentDsParentStats OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Parents stats (always false)."
|
|
::= { me1200PtpStatusClocksParentDsEntry 4 }
|
|
|
|
me1200PtpStatusClocksParentDsObservedParentOffsetScaledLogVar OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field is optional and is not computed (as signaled by parentStats
|
|
being false)."
|
|
::= { me1200PtpStatusClocksParentDsEntry 5 }
|
|
|
|
me1200PtpStatusClocksParentDsObservedParentClockPhaseChangeRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field is optional and is not computed (as signaled by parentStats
|
|
being false)."
|
|
::= { me1200PtpStatusClocksParentDsEntry 6 }
|
|
|
|
me1200PtpStatusClocksParentDsGrmstrIdentity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the 8 byte unique clock identity of the grand master clock."
|
|
::= { me1200PtpStatusClocksParentDsEntry 7 }
|
|
|
|
me1200PtpStatusClocksParentDsGrmstrClkQualClockClass OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock class of the clock quality structure of the grand
|
|
master clock."
|
|
::= { me1200PtpStatusClocksParentDsEntry 8 }
|
|
|
|
me1200PtpStatusClocksParentDsGmstrClkQualClockAccuracy OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock accuracy of the clock quality structure of the grand
|
|
master clock."
|
|
::= { me1200PtpStatusClocksParentDsEntry 9 }
|
|
|
|
me1200PtpStatusClocksParentDsGmstrClkQualOffsetScaledLogVar OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the offsetScaledLogVariance field of the clock quality
|
|
structure of the grand master clock."
|
|
::= { me1200PtpStatusClocksParentDsEntry 10 }
|
|
|
|
me1200PtpStatusClocksParentDsGmstrPriority1 OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Grandmaster Priority1 value."
|
|
::= { me1200PtpStatusClocksParentDsEntry 11 }
|
|
|
|
me1200PtpStatusClocksParentDsGmstrPriority2 OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Grandmaster Priority2 value."
|
|
::= { me1200PtpStatusClocksParentDsEntry 12 }
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpStatusClocksTimePropertiesDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the dynamic (status) part of the PTP clocks TimePropertiesDS."
|
|
::= { me1200PtpStatusClocks 4 }
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpStatusClocksTimePropertiesDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpStatusClocksTimePropertiesDsClockId }
|
|
::= { me1200PtpStatusClocksTimePropertiesDsTable 1 }
|
|
|
|
ME1200PtpStatusClocksTimePropertiesDsEntry ::= SEQUENCE {
|
|
me1200PtpStatusClocksTimePropertiesDsClockId Integer32,
|
|
me1200PtpStatusClocksTimePropertiesDsCurrentUtcOffset ME1200Integer16,
|
|
me1200PtpStatusClocksTimePropertiesDsCurrentUtcOffsetValid TruthValue,
|
|
me1200PtpStatusClocksTimePropertiesDsLeap59 TruthValue,
|
|
me1200PtpStatusClocksTimePropertiesDsLeap61 TruthValue,
|
|
me1200PtpStatusClocksTimePropertiesDsTimeTraceable TruthValue,
|
|
me1200PtpStatusClocksTimePropertiesDsFrequencyTraceable TruthValue,
|
|
me1200PtpStatusClocksTimePropertiesDsPtpTimescale TruthValue,
|
|
me1200PtpStatusClocksTimePropertiesDsTimeSource ME1200Unsigned8
|
|
}
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksTimePropertiesDsEntry 1 }
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsCurrentUtcOffset OBJECT-TYPE
|
|
SYNTAX ME1200Integer16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current UTC time offset."
|
|
::= { me1200PtpStatusClocksTimePropertiesDsEntry 2 }
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsCurrentUtcOffsetValid OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the current UTC time offset value is valid."
|
|
::= { me1200PtpStatusClocksTimePropertiesDsEntry 3 }
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsLeap59 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the last minute of the day has only 59 seconds."
|
|
::= { me1200PtpStatusClocksTimePropertiesDsEntry 4 }
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsLeap61 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the last minute of the day has 61 seconds."
|
|
::= { me1200PtpStatusClocksTimePropertiesDsEntry 5 }
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsTimeTraceable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that time is traceable to a primary reference."
|
|
::= { me1200PtpStatusClocksTimePropertiesDsEntry 6 }
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsFrequencyTraceable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that frequency is traceable to a primary reference."
|
|
::= { me1200PtpStatusClocksTimePropertiesDsEntry 7 }
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsPtpTimescale OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether timescale of the grandmaster clock is PTP."
|
|
::= { me1200PtpStatusClocksTimePropertiesDsEntry 8 }
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsTimeSource OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Source of time used by the grandmaster clock."
|
|
::= { me1200PtpStatusClocksTimePropertiesDsEntry 9 }
|
|
|
|
me1200PtpStatusClocksSlaveDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpStatusClocksSlaveDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the dynamic (status) part of the PTP clocks SlaveDS."
|
|
::= { me1200PtpStatusClocks 5 }
|
|
|
|
me1200PtpStatusClocksSlaveDsEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpStatusClocksSlaveDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpStatusClocksSlaveDsClockId }
|
|
::= { me1200PtpStatusClocksSlaveDsTable 1 }
|
|
|
|
ME1200PtpStatusClocksSlaveDsEntry ::= SEQUENCE {
|
|
me1200PtpStatusClocksSlaveDsClockId Integer32,
|
|
me1200PtpStatusClocksSlaveDsSlavePort ME1200Unsigned16,
|
|
me1200PtpStatusClocksSlaveDsSlaveState ME1200ptpSlaveClockState,
|
|
me1200PtpStatusClocksSlaveDsHoldoverStable ME1200Unsigned8,
|
|
me1200PtpStatusClocksSlaveDsHoldoverAdj ME1200Integer64
|
|
}
|
|
|
|
me1200PtpStatusClocksSlaveDsClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksSlaveDsEntry 1 }
|
|
|
|
me1200PtpStatusClocksSlaveDsSlavePort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"0 => no slave port, 1..n => selected slave port."
|
|
::= { me1200PtpStatusClocksSlaveDsEntry 2 }
|
|
|
|
me1200PtpStatusClocksSlaveDsSlaveState OBJECT-TYPE
|
|
SYNTAX ME1200ptpSlaveClockState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slaves state."
|
|
::= { me1200PtpStatusClocksSlaveDsEntry 3 }
|
|
|
|
me1200PtpStatusClocksSlaveDsHoldoverStable OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True if the stabilization period has expired."
|
|
::= { me1200PtpStatusClocksSlaveDsEntry 4 }
|
|
|
|
me1200PtpStatusClocksSlaveDsHoldoverAdj OBJECT-TYPE
|
|
SYNTAX ME1200Integer64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The calculated holdover offset (ppb*10)."
|
|
::= { me1200PtpStatusClocksSlaveDsEntry 5 }
|
|
|
|
me1200PtpStatusClocksUnicastMasterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpStatusClocksUnicastMasterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the dynamic (status) part of the PTP clocks unicast master
|
|
table."
|
|
::= { me1200PtpStatusClocks 6 }
|
|
|
|
me1200PtpStatusClocksUnicastMasterEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpStatusClocksUnicastMasterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpStatusClocksUnicastMasterClockId, me1200PtpStatusClocksUnicastMasterSlaveIp }
|
|
::= { me1200PtpStatusClocksUnicastMasterTable 1 }
|
|
|
|
ME1200PtpStatusClocksUnicastMasterEntry ::= SEQUENCE {
|
|
me1200PtpStatusClocksUnicastMasterClockId Integer32,
|
|
me1200PtpStatusClocksUnicastMasterSlaveIp IpAddress,
|
|
me1200PtpStatusClocksUnicastMasterSlaveMac MacAddress,
|
|
me1200PtpStatusClocksUnicastMasterPort ME1200Unsigned16,
|
|
me1200PtpStatusClocksUnicastMasterAnnLogMsgPeriod ME1200Integer16,
|
|
me1200PtpStatusClocksUnicastMasterAnn TruthValue,
|
|
me1200PtpStatusClocksUnicastMasterLogMsgPeriod ME1200Integer16,
|
|
me1200PtpStatusClocksUnicastMasterSync TruthValue
|
|
}
|
|
|
|
me1200PtpStatusClocksUnicastMasterClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksUnicastMasterEntry 1 }
|
|
|
|
me1200PtpStatusClocksUnicastMasterSlaveIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksUnicastMasterEntry 2 }
|
|
|
|
me1200PtpStatusClocksUnicastMasterSlaveMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksUnicastMasterEntry 3 }
|
|
|
|
me1200PtpStatusClocksUnicastMasterPort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port on the master that slave is connected to."
|
|
::= { me1200PtpStatusClocksUnicastMasterEntry 4 }
|
|
|
|
me1200PtpStatusClocksUnicastMasterAnnLogMsgPeriod OBJECT-TYPE
|
|
SYNTAX ME1200Integer16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The granted Announce interval."
|
|
::= { me1200PtpStatusClocksUnicastMasterEntry 5 }
|
|
|
|
me1200PtpStatusClocksUnicastMasterAnn OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True if sending announce messages."
|
|
::= { me1200PtpStatusClocksUnicastMasterEntry 6 }
|
|
|
|
me1200PtpStatusClocksUnicastMasterLogMsgPeriod OBJECT-TYPE
|
|
SYNTAX ME1200Integer16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The granted sync interval."
|
|
::= { me1200PtpStatusClocksUnicastMasterEntry 7 }
|
|
|
|
me1200PtpStatusClocksUnicastMasterSync OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True if sending sync messages."
|
|
::= { me1200PtpStatusClocksUnicastMasterEntry 8 }
|
|
|
|
me1200PtpStatusClocksUnicastSlaveTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpStatusClocksUnicastSlaveEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the dynamic (status) part of the PTP clocks unicast slave
|
|
table."
|
|
::= { me1200PtpStatusClocks 7 }
|
|
|
|
me1200PtpStatusClocksUnicastSlaveEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpStatusClocksUnicastSlaveEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpStatusClocksUnicastSlaveClockId, me1200PtpStatusClocksUnicastSlaveMasterId }
|
|
::= { me1200PtpStatusClocksUnicastSlaveTable 1 }
|
|
|
|
ME1200PtpStatusClocksUnicastSlaveEntry ::= SEQUENCE {
|
|
me1200PtpStatusClocksUnicastSlaveClockId Integer32,
|
|
me1200PtpStatusClocksUnicastSlaveMasterId Integer32,
|
|
me1200PtpStatusClocksUnicastSlaveMasterIp IpAddress,
|
|
me1200PtpStatusClocksUnicastSlaveMasterMac MacAddress,
|
|
me1200PtpStatusClocksUnicastSlaveSourcePortIdentityClockIdentity OCTET STRING,
|
|
me1200PtpStatusClocksUnicastSlaveSourcePortIdentityPortNumber ME1200Unsigned16,
|
|
me1200PtpStatusClocksUnicastSlavePort ME1200Unsigned16,
|
|
me1200PtpStatusClocksUnicastSlaveLogMsgPeriod ME1200Integer16,
|
|
me1200PtpStatusClocksUnicastSlaveCommState ME1200ptpUcCommState,
|
|
me1200PtpStatusClocksUnicastSlaveConfMasterIp IpAddress
|
|
}
|
|
|
|
me1200PtpStatusClocksUnicastSlaveClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksUnicastSlaveEntry 1 }
|
|
|
|
me1200PtpStatusClocksUnicastSlaveMasterId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksUnicastSlaveEntry 2 }
|
|
|
|
me1200PtpStatusClocksUnicastSlaveMasterIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the IP address of the master."
|
|
::= { me1200PtpStatusClocksUnicastSlaveEntry 3 }
|
|
|
|
me1200PtpStatusClocksUnicastSlaveMasterMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the MAC address of the master."
|
|
::= { me1200PtpStatusClocksUnicastSlaveEntry 4 }
|
|
|
|
me1200PtpStatusClocksUnicastSlaveSourcePortIdentityClockIdentity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the 8 byte unique clock identity of the source port."
|
|
::= { me1200PtpStatusClocksUnicastSlaveEntry 5 }
|
|
|
|
me1200PtpStatusClocksUnicastSlaveSourcePortIdentityPortNumber OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is port number of the port used on the source."
|
|
::= { me1200PtpStatusClocksUnicastSlaveEntry 6 }
|
|
|
|
me1200PtpStatusClocksUnicastSlavePort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port (on the slave) connected to the master."
|
|
::= { me1200PtpStatusClocksUnicastSlaveEntry 7 }
|
|
|
|
me1200PtpStatusClocksUnicastSlaveLogMsgPeriod OBJECT-TYPE
|
|
SYNTAX ME1200Integer16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The granted sync interval."
|
|
::= { me1200PtpStatusClocksUnicastSlaveEntry 8 }
|
|
|
|
me1200PtpStatusClocksUnicastSlaveCommState OBJECT-TYPE
|
|
SYNTAX ME1200ptpUcCommState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Communication state."
|
|
::= { me1200PtpStatusClocksUnicastSlaveEntry 9 }
|
|
|
|
me1200PtpStatusClocksUnicastSlaveConfMasterIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Copy of the destination ip address."
|
|
::= { me1200PtpStatusClocksUnicastSlaveEntry 10 }
|
|
|
|
me1200PtpStatusClocksPortsDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpStatusClocksPortsDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the dynamic (status) part of the PTP clocks PortDS."
|
|
::= { me1200PtpStatusClocks 8 }
|
|
|
|
me1200PtpStatusClocksPortsDsEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpStatusClocksPortsDsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpStatusClocksPortsDsClockId, me1200PtpStatusClocksPortsDsPortId }
|
|
::= { me1200PtpStatusClocksPortsDsTable 1 }
|
|
|
|
ME1200PtpStatusClocksPortsDsEntry ::= SEQUENCE {
|
|
me1200PtpStatusClocksPortsDsClockId Integer32,
|
|
me1200PtpStatusClocksPortsDsPortId ME1200InterfaceIndex,
|
|
me1200PtpStatusClocksPortsDsPortState ME1200ptpClockPortState,
|
|
me1200PtpStatusClocksPortsDsLogMinDelayReqInterval ME1200Integer16,
|
|
me1200PtpStatusClocksPortsDsPeerMeanPathDelay ME1200Integer64,
|
|
me1200PtpStatusClocksPortsDsPeerDelayOk TruthValue
|
|
}
|
|
|
|
me1200PtpStatusClocksPortsDsClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksPortsDsEntry 1 }
|
|
|
|
me1200PtpStatusClocksPortsDsPortId OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksPortsDsEntry 2 }
|
|
|
|
me1200PtpStatusClocksPortsDsPortState OBJECT-TYPE
|
|
SYNTAX ME1200ptpClockPortState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksPortsDsEntry 3 }
|
|
|
|
me1200PtpStatusClocksPortsDsLogMinDelayReqInterval OBJECT-TYPE
|
|
SYNTAX ME1200Integer16
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksPortsDsEntry 4 }
|
|
|
|
me1200PtpStatusClocksPortsDsPeerMeanPathDelay OBJECT-TYPE
|
|
SYNTAX ME1200Integer64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksPortsDsEntry 5 }
|
|
|
|
me1200PtpStatusClocksPortsDsPeerDelayOk OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpStatusClocksPortsDsEntry 6 }
|
|
|
|
me1200PtpControl OBJECT IDENTIFIER
|
|
::= { me1200PtpMibObjects 4 }
|
|
|
|
me1200PtpControlClocksTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200PtpControlClocksEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the PTP clocks control structure."
|
|
::= { me1200PtpControl 1 }
|
|
|
|
me1200PtpControlClocksEntry OBJECT-TYPE
|
|
SYNTAX ME1200PtpControlClocksEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clockId index must be a value must be a value from 0 up to the
|
|
number of PTP clocks minus one."
|
|
INDEX { me1200PtpControlClocksClockId }
|
|
::= { me1200PtpControlClocksTable 1 }
|
|
|
|
ME1200PtpControlClocksEntry ::= SEQUENCE {
|
|
me1200PtpControlClocksClockId Integer32,
|
|
me1200PtpControlClocksSyncToSystemClock ME1200Unsigned8
|
|
}
|
|
|
|
me1200PtpControlClocksClockId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpControlClocksEntry 1 }
|
|
|
|
me1200PtpControlClocksSyncToSystemClock OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200PtpControlClocksEntry 2 }
|
|
|
|
me1200PtpStatistics OBJECT IDENTIFIER
|
|
::= { me1200PtpMibObjects 5 }
|
|
|
|
me1200PtpNotifs OBJECT IDENTIFIER
|
|
::= { me1200PtpMibObjects 6 }
|
|
|
|
me1200PtpNotifsPortStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
me1200PtpStatusClocksPortsDsPortId,
|
|
me1200PtpStatusClocksPortsDsPortState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An me1200PtpNotifsPortStateChange notification is sent when the Port State changes occurs.
|
|
Port State is an enumerated integer value. Description of various possible Port States is:
|
|
|
|
initializing - In this state a port initializes
|
|
its data sets, hardware, and
|
|
communication facilities.
|
|
|
|
faulty - The fault state of the protocol.
|
|
|
|
disabled - The port shall not place any
|
|
messages on its communication path.
|
|
|
|
listening - The port is waiting for the
|
|
announceReceiptTimeout to expire or
|
|
to receive an Announce message from
|
|
a master.
|
|
|
|
preMaster - The port shall behave in all respects
|
|
as though it were in the MASTER state
|
|
except that it shall not place any
|
|
messages on its communication path
|
|
except for Pdelay_Req, Pdelay_Resp,
|
|
Pdelay_Resp_Follow_Up, signaling, or
|
|
management messages.
|
|
master - The port is behaving as a master port.
|
|
|
|
passive - The port shall not place any
|
|
messages on its communication path
|
|
except for Pdelay_Req, Pdelay_Resp,
|
|
Pdelay_Resp_Follow_Up, or signaling
|
|
messages, or management messages
|
|
that are a required response to
|
|
another management message
|
|
|
|
uncalibrated - The local port is preparing to
|
|
synchronize to the master port.
|
|
|
|
slave - The port is synchronizing to the
|
|
selected master port.
|
|
|
|
p2pTransparent - The port is in point to point
|
|
transparent state.
|
|
|
|
e2eTransparent - The port is in end to end
|
|
transparent state."
|
|
::= { me1200PtpNotifs 1 }
|
|
|
|
me1200PtpNotifsClockSlaveStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
me1200PtpStatusClocksSlaveDsClockId,
|
|
me1200PtpStatusClocksSlaveDsSlaveState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An me1200PtpNotifsClockSlaveStateChange notification is sent when the clock slave state changes.
|
|
Clock Slave Sate is an enumerated integer value. Description of various possible Port States is:
|
|
|
|
Freerun - Applies to a slave device that is not locked to
|
|
a master. This is the initial state a slave starts out with
|
|
when it is not getting any PTP packets from the master or because of
|
|
some other input error (erroneous packets, etc).
|
|
FreqLocking - The slave device is receiving packets from a
|
|
master and is trying to acquire a frequency lock.
|
|
PhaseLocking - The slave device is receiving packets from a
|
|
master and is trying to acquire a phase lock.
|
|
Locked - Locked to the master with respect to
|
|
frequency and phase.
|
|
Holdover - In this state the slave device is locked to a
|
|
master but communication with the master is lost or the
|
|
timestamps in the ptp packets are incorrect. But since the
|
|
slave was locked to the master, it can run with the same
|
|
accuracy for
|
|
sometime. The slave can continue to operate in this state for
|
|
some time. If communication with the master is not restored for
|
|
a while, the device is moved to the FREERUN state.
|
|
Invalid - The slave is in Invalid state.
|
|
"
|
|
::= { me1200PtpNotifs 2 }
|
|
|
|
me1200PtpNotifsUnicastCommunicationStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
me1200PtpStatusClocksUnicastSlaveCommState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An me1200PtpNotifsUnicastCommunicationStateChange notification is sent when the unicast communication
|
|
state changes (A unicast slave reports change in the communication state to the configured masters).
|
|
Unicast communication state is an enumerated integer value.
|
|
Description of various possible states is:
|
|
|
|
idle - When communication state is idle.
|
|
intializing - When communication state is initializing.
|
|
connected - When communication state is connected.
|
|
selected - When communication state is selected.
|
|
synced - When communication state is synced.
|
|
"
|
|
::= { me1200PtpNotifs 3 }
|
|
|
|
me1200PtpNotifsUnicastSlaveAppears NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
me1200PtpStatusClocksUnicastMasterSlaveIp
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An me1200PtpNotifsUnicastSlaveAppears notification is sent when a unicast slave appears.
|
|
"
|
|
::= { me1200PtpNotifs 4 }
|
|
|
|
me1200PtpNotifsUnicastSlaveDisappears NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
me1200PtpStatusClocksUnicastMasterSlaveIp
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An me1200PtpNotifsUnicastSlaveDisappears notification is sent when a unicast slave disappears.
|
|
"
|
|
::= { me1200PtpNotifs 5 }
|
|
|
|
me1200PtpMibConformance OBJECT IDENTIFIER
|
|
::= { me1200PtpMib 2 }
|
|
|
|
me1200PtpMibCompliances OBJECT IDENTIFIER
|
|
::= { me1200PtpMibConformance 1 }
|
|
|
|
me1200PtpMibGroups OBJECT IDENTIFIER
|
|
::= { me1200PtpMibConformance 2 }
|
|
|
|
me1200PtpCapabilitiesGlobalsInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpCapabilitiesGlobalsClockCount }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 1 }
|
|
|
|
me1200PtpConfigGlobalsExternalClockModeInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpConfigGlobalsExternalClockModeOnePpsMode,
|
|
me1200PtpConfigGlobalsExternalClockModeExternalEnable,
|
|
me1200PtpConfigGlobalsExternalClockModeAdjustMethod,
|
|
me1200PtpConfigGlobalsExternalClockModeClockFrequency }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 2 }
|
|
|
|
me1200PtpConfigGlobalsSystemTimeSyncModeInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpConfigGlobalsSystemTimeSyncModeMode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 3 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpConfigClocksDefaultDsDeviceType,
|
|
me1200PtpConfigClocksDefaultDsTwoStepFlag,
|
|
me1200PtpConfigClocksDefaultDsPriority1,
|
|
me1200PtpConfigClocksDefaultDsPriority2,
|
|
me1200PtpConfigClocksDefaultDsOneWay,
|
|
me1200PtpConfigClocksDefaultDsDomainNumber,
|
|
me1200PtpConfigClocksDefaultDsProtocol,
|
|
me1200PtpConfigClocksDefaultDsVlanTagEnable,
|
|
me1200PtpConfigClocksDefaultDsVid,
|
|
me1200PtpConfigClocksDefaultDsPcp,
|
|
me1200PtpConfigClocksDefaultDsMep,
|
|
me1200PtpConfigClocksDefaultDsClkDom,
|
|
me1200PtpConfigClocksDefaultDsDscp,
|
|
me1200PtpConfigClocksDefaultDsProfile,
|
|
me1200PtpConfigClocksDefaultDsLocalPriority,
|
|
me1200PtpConfigClocksDefaultDsAction }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 4 }
|
|
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpConfigClocksDefaultDsTableRowEditorClockId,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorDeviceType,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorTwoStepFlag,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorPriority1,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorPriority2,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorOneWay,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorDomainNumber,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorProtocol,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorVlanTagEnable,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorVid,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorPcp,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorMep,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorClkDom,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorDscp,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorProfile,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorLocalPriority,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorAction }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 5 }
|
|
|
|
me1200PtpConfigClocksTimePropertiesDsTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpConfigClocksTimePropertiesDsCurrentUtcOffset,
|
|
me1200PtpConfigClocksTimePropertiesDsCurrentUtcOffsetValid,
|
|
me1200PtpConfigClocksTimePropertiesDsLeap59,
|
|
me1200PtpConfigClocksTimePropertiesDsLeap61,
|
|
me1200PtpConfigClocksTimePropertiesDsTimeTraceable,
|
|
me1200PtpConfigClocksTimePropertiesDsFrequencyTraceable,
|
|
me1200PtpConfigClocksTimePropertiesDsPtpTimescale,
|
|
me1200PtpConfigClocksTimePropertiesDsTimeSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 6 }
|
|
|
|
me1200PtpConfigClocksFilterParametersTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpConfigClocksFilterParametersDelayFilter,
|
|
me1200PtpConfigClocksFilterParametersFilterType,
|
|
me1200PtpConfigClocksFilterParametersPeriod,
|
|
me1200PtpConfigClocksFilterParametersDist }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 7 }
|
|
|
|
me1200PtpConfigClocksServoParametersTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpConfigClocksServoParametersDisplay,
|
|
me1200PtpConfigClocksServoParametersPEnable,
|
|
me1200PtpConfigClocksServoParametersIEnable,
|
|
me1200PtpConfigClocksServoParametersDEnable,
|
|
me1200PtpConfigClocksServoParametersPval,
|
|
me1200PtpConfigClocksServoParametersIval,
|
|
me1200PtpConfigClocksServoParametersDval,
|
|
me1200PtpConfigClocksServoParametersSrvOption,
|
|
me1200PtpConfigClocksServoParametersSynceThreshold,
|
|
me1200PtpConfigClocksServoParametersSynceAp,
|
|
me1200PtpConfigClocksServoParametersHoFilter,
|
|
me1200PtpConfigClocksServoParametersStableAdjThreshold }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 8 }
|
|
|
|
me1200PtpConfigClocksSlaveConfigTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpConfigClocksSlaveConfigStableOffset,
|
|
me1200PtpConfigClocksSlaveConfigOffsetOk,
|
|
me1200PtpConfigClocksSlaveConfigOffsetFail }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 9 }
|
|
|
|
me1200PtpConfigClocksUnicastSlaveConfigTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpConfigClocksUnicastSlaveConfigDuration,
|
|
me1200PtpConfigClocksUnicastSlaveConfigIpAddress }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 10 }
|
|
|
|
me1200PtpConfigClocksPortDsTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpConfigClocksPortDsEnabled,
|
|
me1200PtpConfigClocksPortDsLogAnnounceInterval,
|
|
me1200PtpConfigClocksPortDsAnnounceReceiptTimeout,
|
|
me1200PtpConfigClocksPortDsLogSyncInterval,
|
|
me1200PtpConfigClocksPortDsDelayMechanism,
|
|
me1200PtpConfigClocksPortDsLogMinPdelayReqInterval,
|
|
me1200PtpConfigClocksPortDsDelayAsymmetry,
|
|
me1200PtpConfigClocksPortDsIngressLatency,
|
|
me1200PtpConfigClocksPortDsEgressLatency,
|
|
me1200PtpConfigClocksPortDsPortInternal,
|
|
me1200PtpConfigClocksPortDsVersionNumber,
|
|
me1200PtpConfigClocksPortDsMcastAddr,
|
|
me1200PtpConfigClocksPortDsNotSlave,
|
|
me1200PtpConfigClocksPortDsLocalPriority }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 11 }
|
|
|
|
me1200PtpStatusClocksDefaultDsTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpStatusClocksDefaultDsClockIdentity,
|
|
me1200PtpStatusClocksDefaultDsClockQualityClockClass,
|
|
me1200PtpStatusClocksDefaultDsClockQualityClockAccuracy,
|
|
me1200PtpStatusClocksDefaultDsClockQualityOffsetScaledLogVar }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 12 }
|
|
|
|
me1200PtpStatusClocksCurrentDsTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpStatusClocksCurrentDsStepsRemoved,
|
|
me1200PtpStatusClocksCurrentDsOffsetFromMaster,
|
|
me1200PtpStatusClocksCurrentDsMeanPathDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 13 }
|
|
|
|
me1200PtpStatusClocksParentDsTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpStatusClocksParentDsParentPortIdentityClockIdentity,
|
|
me1200PtpStatusClocksParentDsParentPortIdentityPortNumber,
|
|
me1200PtpStatusClocksParentDsParentStats,
|
|
me1200PtpStatusClocksParentDsObservedParentOffsetScaledLogVar,
|
|
me1200PtpStatusClocksParentDsObservedParentClockPhaseChangeRate,
|
|
me1200PtpStatusClocksParentDsGrmstrIdentity,
|
|
me1200PtpStatusClocksParentDsGrmstrClkQualClockClass,
|
|
me1200PtpStatusClocksParentDsGmstrClkQualClockAccuracy,
|
|
me1200PtpStatusClocksParentDsGmstrClkQualOffsetScaledLogVar,
|
|
me1200PtpStatusClocksParentDsGmstrPriority1,
|
|
me1200PtpStatusClocksParentDsGmstrPriority2 }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 14 }
|
|
|
|
me1200PtpStatusClocksTimePropertiesDsTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpStatusClocksTimePropertiesDsCurrentUtcOffset,
|
|
me1200PtpStatusClocksTimePropertiesDsCurrentUtcOffsetValid,
|
|
me1200PtpStatusClocksTimePropertiesDsLeap59,
|
|
me1200PtpStatusClocksTimePropertiesDsLeap61,
|
|
me1200PtpStatusClocksTimePropertiesDsTimeTraceable,
|
|
me1200PtpStatusClocksTimePropertiesDsFrequencyTraceable,
|
|
me1200PtpStatusClocksTimePropertiesDsPtpTimescale,
|
|
me1200PtpStatusClocksTimePropertiesDsTimeSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 15 }
|
|
|
|
me1200PtpStatusClocksSlaveDsTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpStatusClocksSlaveDsSlavePort,
|
|
me1200PtpStatusClocksSlaveDsSlaveState,
|
|
me1200PtpStatusClocksSlaveDsHoldoverStable,
|
|
me1200PtpStatusClocksSlaveDsHoldoverAdj }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 16 }
|
|
|
|
me1200PtpStatusClocksUnicastMasterTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpStatusClocksUnicastMasterSlaveMac,
|
|
me1200PtpStatusClocksUnicastMasterPort,
|
|
me1200PtpStatusClocksUnicastMasterAnnLogMsgPeriod,
|
|
me1200PtpStatusClocksUnicastMasterAnn,
|
|
me1200PtpStatusClocksUnicastMasterLogMsgPeriod,
|
|
me1200PtpStatusClocksUnicastMasterSync }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 17 }
|
|
|
|
me1200PtpStatusClocksUnicastSlaveTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpStatusClocksUnicastSlaveMasterIp,
|
|
me1200PtpStatusClocksUnicastSlaveMasterMac,
|
|
me1200PtpStatusClocksUnicastSlaveSourcePortIdentityClockIdentity,
|
|
me1200PtpStatusClocksUnicastSlaveSourcePortIdentityPortNumber,
|
|
me1200PtpStatusClocksUnicastSlavePort,
|
|
me1200PtpStatusClocksUnicastSlaveLogMsgPeriod,
|
|
me1200PtpStatusClocksUnicastSlaveCommState,
|
|
me1200PtpStatusClocksUnicastSlaveConfMasterIp }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 18 }
|
|
|
|
me1200PtpStatusClocksPortsDsTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpStatusClocksPortsDsPortState,
|
|
me1200PtpStatusClocksPortsDsLogMinDelayReqInterval,
|
|
me1200PtpStatusClocksPortsDsPeerMeanPathDelay,
|
|
me1200PtpStatusClocksPortsDsPeerDelayOk }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 19 }
|
|
|
|
me1200PtpControlClocksTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200PtpControlClocksSyncToSystemClock }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200PtpMibGroups 20 }
|
|
|
|
me1200PtpNotifsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
me1200PtpNotifsPortStateChange,
|
|
me1200PtpNotifsClockSlaveStateChange,
|
|
me1200PtpNotifsUnicastCommunicationStateChange,
|
|
me1200PtpNotifsUnicastSlaveAppears,
|
|
me1200PtpNotifsUnicastSlaveDisappears
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PTP Nofication events' group."
|
|
::= { me1200PtpMibGroups 21 }
|
|
|
|
me1200PtpMibCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the implementation."
|
|
|
|
MODULE -- this module
|
|
|
|
MANDATORY-GROUPS { me1200PtpCapabilitiesGlobalsInfoGroup,
|
|
me1200PtpConfigGlobalsExternalClockModeInfoGroup,
|
|
me1200PtpConfigGlobalsSystemTimeSyncModeInfoGroup,
|
|
me1200PtpConfigClocksDefaultDsTableInfoGroup,
|
|
me1200PtpConfigClocksDefaultDsTableRowEditorInfoGroup,
|
|
me1200PtpConfigClocksTimePropertiesDsTableInfoGroup,
|
|
me1200PtpConfigClocksFilterParametersTableInfoGroup,
|
|
me1200PtpConfigClocksServoParametersTableInfoGroup,
|
|
me1200PtpConfigClocksSlaveConfigTableInfoGroup,
|
|
me1200PtpConfigClocksUnicastSlaveConfigTableInfoGroup,
|
|
me1200PtpConfigClocksPortDsTableInfoGroup,
|
|
me1200PtpStatusClocksDefaultDsTableInfoGroup,
|
|
me1200PtpStatusClocksCurrentDsTableInfoGroup,
|
|
me1200PtpStatusClocksParentDsTableInfoGroup,
|
|
me1200PtpStatusClocksTimePropertiesDsTableInfoGroup,
|
|
me1200PtpStatusClocksSlaveDsTableInfoGroup,
|
|
me1200PtpStatusClocksUnicastMasterTableInfoGroup,
|
|
me1200PtpStatusClocksUnicastSlaveTableInfoGroup,
|
|
me1200PtpStatusClocksPortsDsTableInfoGroup,
|
|
me1200PtpControlClocksTableInfoGroup,
|
|
me1200PtpNotifsGroup }
|
|
|
|
::= { me1200PtpMibCompliances 1 }
|
|
|
|
END
|