364 lines
13 KiB
Plaintext
364 lines
13 KiB
Plaintext
-- *********************************************************************
|
|
-- CISCO-UNIFIED-COMPUTING-CONTROLLER-MIB.my
|
|
--
|
|
-- MIB representation of the Cisco Unified Computing System
|
|
-- CONTROLLER management information model package
|
|
--
|
|
-- Created July 2018 by Charles Bullis
|
|
--
|
|
-- Copyright (c) 2005-2018 Cisco Systems, Inc. All rights reserved.
|
|
--
|
|
-- *********************************************************************
|
|
|
|
CISCO-UNIFIED-COMPUTING-CONTROLLER-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Counter32,
|
|
Gauge32,
|
|
TimeTicks,
|
|
Counter64,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
RowPointer,
|
|
DateAndTime,
|
|
DisplayString,
|
|
MacAddress,
|
|
TimeInterval,
|
|
TimeStamp,
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
InetAddressIPv4,
|
|
InetAddressIPv6
|
|
FROM INET-ADDRESS-MIB
|
|
ciscoMgmt
|
|
FROM CISCO-SMI
|
|
CiscoNetworkAddress,
|
|
Unsigned64,
|
|
CiscoInetAddressMask,
|
|
CiscoAlarmSeverity,
|
|
TimeIntervalSec
|
|
FROM CISCO-TC
|
|
ciscoUnifiedComputingMIBObjects,
|
|
CucsManagedObjectId,
|
|
CucsManagedObjectDn
|
|
FROM CISCO-UNIFIED-COMPUTING-MIB;
|
|
|
|
cucsControllerObjects MODULE-IDENTITY
|
|
LAST-UPDATED "201807260000Z"
|
|
ORGANIZATION "Cisco Systems Inc."
|
|
CONTACT-INFO
|
|
"Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel: +1 800 553 -NETS
|
|
|
|
E-mail: cs-san@cisco.com, cs-lan-switch-snmp@cisco.com"
|
|
DESCRIPTION
|
|
"MIB representation of the Cisco Unified Computing System
|
|
CONTROLLER management information model package"
|
|
::= { ciscoUnifiedComputingMIBObjects 83 }
|
|
|
|
cucsControllerHaControllerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CucsControllerHaControllerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:HaController managed object table"
|
|
::= { cucsControllerObjects 5 }
|
|
|
|
cucsControllerHaControllerEntry OBJECT-TYPE
|
|
SYNTAX CucsControllerHaControllerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for the cucsControllerHaControllerTable table."
|
|
INDEX { cucsControllerHaControllerInstanceId }
|
|
::= { cucsControllerHaControllerTable 1 }
|
|
|
|
CucsControllerHaControllerEntry ::= SEQUENCE {
|
|
cucsControllerHaControllerInstanceId CucsManagedObjectId,
|
|
cucsControllerHaControllerDn CucsManagedObjectDn,
|
|
cucsControllerHaControllerRn SnmpAdminString,
|
|
cucsControllerHaControllerTrigElectionFlag TruthValue
|
|
}
|
|
|
|
cucsControllerHaControllerInstanceId OBJECT-TYPE
|
|
SYNTAX CucsManagedObjectId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instance identifier of the managed object."
|
|
::= { cucsControllerHaControllerEntry 1 }
|
|
|
|
cucsControllerHaControllerDn OBJECT-TYPE
|
|
SYNTAX CucsManagedObjectDn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:HaController:dn managed object property"
|
|
::= { cucsControllerHaControllerEntry 2 }
|
|
|
|
cucsControllerHaControllerRn OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:HaController:rn managed object property"
|
|
::= { cucsControllerHaControllerEntry 3 }
|
|
|
|
cucsControllerHaControllerTrigElectionFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:HaController:trigElectionFlag
|
|
managed object property"
|
|
::= { cucsControllerHaControllerEntry 4 }
|
|
|
|
cucsControllerMgmtDbCheckPolTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CucsControllerMgmtDbCheckPolEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:MgmtDbCheckPol managed object table"
|
|
::= { cucsControllerObjects 8 }
|
|
|
|
cucsControllerMgmtDbCheckPolEntry OBJECT-TYPE
|
|
SYNTAX CucsControllerMgmtDbCheckPolEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for the cucsControllerMgmtDbCheckPolTable table."
|
|
INDEX { cucsControllerMgmtDbCheckPolInstanceId }
|
|
::= { cucsControllerMgmtDbCheckPolTable 1 }
|
|
|
|
CucsControllerMgmtDbCheckPolEntry ::= SEQUENCE {
|
|
cucsControllerMgmtDbCheckPolInstanceId CucsManagedObjectId,
|
|
cucsControllerMgmtDbCheckPolDn CucsManagedObjectDn,
|
|
cucsControllerMgmtDbCheckPolRn SnmpAdminString,
|
|
cucsControllerMgmtDbCheckPolHealthCheckInterval Gauge32,
|
|
cucsControllerMgmtDbCheckPolInternalBackupInterval Gauge32,
|
|
cucsControllerMgmtDbCheckPolLastIntegrityCheckTime DateAndTime,
|
|
cucsControllerMgmtDbCheckPolLastInternalBackupTime DateAndTime,
|
|
cucsControllerMgmtDbCheckPolResetCorruptCount TruthValue,
|
|
cucsControllerMgmtDbCheckPolTriggerHealthCheck TruthValue
|
|
}
|
|
|
|
cucsControllerMgmtDbCheckPolInstanceId OBJECT-TYPE
|
|
SYNTAX CucsManagedObjectId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instance identifier of the managed object."
|
|
::= { cucsControllerMgmtDbCheckPolEntry 1 }
|
|
|
|
cucsControllerMgmtDbCheckPolDn OBJECT-TYPE
|
|
SYNTAX CucsManagedObjectDn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:MgmtDbCheckPol:dn managed object property"
|
|
::= { cucsControllerMgmtDbCheckPolEntry 2 }
|
|
|
|
cucsControllerMgmtDbCheckPolRn OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:MgmtDbCheckPol:rn managed object property"
|
|
::= { cucsControllerMgmtDbCheckPolEntry 3 }
|
|
|
|
cucsControllerMgmtDbCheckPolHealthCheckInterval OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:MgmtDbCheckPol:healthCheckInterval
|
|
managed object property"
|
|
::= { cucsControllerMgmtDbCheckPolEntry 4 }
|
|
|
|
cucsControllerMgmtDbCheckPolInternalBackupInterval OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:MgmtDbCheckPol:internalBackupInterval
|
|
managed object property"
|
|
::= { cucsControllerMgmtDbCheckPolEntry 5 }
|
|
|
|
cucsControllerMgmtDbCheckPolLastIntegrityCheckTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:MgmtDbCheckPol:lastIntegrityCheckTime
|
|
managed object property"
|
|
::= { cucsControllerMgmtDbCheckPolEntry 6 }
|
|
|
|
cucsControllerMgmtDbCheckPolLastInternalBackupTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:MgmtDbCheckPol:lastInternalBackupTime
|
|
managed object property"
|
|
::= { cucsControllerMgmtDbCheckPolEntry 7 }
|
|
|
|
cucsControllerMgmtDbCheckPolResetCorruptCount OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:MgmtDbCheckPol:resetCorruptCount
|
|
managed object property"
|
|
::= { cucsControllerMgmtDbCheckPolEntry 8 }
|
|
|
|
cucsControllerMgmtDbCheckPolTriggerHealthCheck OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:MgmtDbCheckPol:triggerHealthCheck
|
|
managed object property"
|
|
::= { cucsControllerMgmtDbCheckPolEntry 9 }
|
|
|
|
cucsControllerOperationalVersionHolderTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CucsControllerOperationalVersionHolderEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:OperationalVersionHolder
|
|
managed object table"
|
|
::= { cucsControllerObjects 6 }
|
|
|
|
cucsControllerOperationalVersionHolderEntry OBJECT-TYPE
|
|
SYNTAX CucsControllerOperationalVersionHolderEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for the cucsControllerOperationalVersionHolderTable table."
|
|
INDEX { cucsControllerOperationalVersionHolderInstanceId }
|
|
::= { cucsControllerOperationalVersionHolderTable 1 }
|
|
|
|
CucsControllerOperationalVersionHolderEntry ::= SEQUENCE {
|
|
cucsControllerOperationalVersionHolderInstanceId CucsManagedObjectId,
|
|
cucsControllerOperationalVersionHolderDn CucsManagedObjectDn,
|
|
cucsControllerOperationalVersionHolderRn SnmpAdminString,
|
|
cucsControllerOperationalVersionHolderSerial SnmpAdminString
|
|
}
|
|
|
|
cucsControllerOperationalVersionHolderInstanceId OBJECT-TYPE
|
|
SYNTAX CucsManagedObjectId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instance identifier of the managed object."
|
|
::= { cucsControllerOperationalVersionHolderEntry 1 }
|
|
|
|
cucsControllerOperationalVersionHolderDn OBJECT-TYPE
|
|
SYNTAX CucsManagedObjectDn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:OperationalVersionHolder:dn
|
|
managed object property"
|
|
::= { cucsControllerOperationalVersionHolderEntry 2 }
|
|
|
|
cucsControllerOperationalVersionHolderRn OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:OperationalVersionHolder:rn
|
|
managed object property"
|
|
::= { cucsControllerOperationalVersionHolderEntry 3 }
|
|
|
|
cucsControllerOperationalVersionHolderSerial OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:OperationalVersionHolder:serial
|
|
managed object property"
|
|
::= { cucsControllerOperationalVersionHolderEntry 4 }
|
|
|
|
cucsControllerPreferedVersionHolderTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CucsControllerPreferedVersionHolderEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:PreferedVersionHolder managed object table"
|
|
::= { cucsControllerObjects 7 }
|
|
|
|
cucsControllerPreferedVersionHolderEntry OBJECT-TYPE
|
|
SYNTAX CucsControllerPreferedVersionHolderEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for the cucsControllerPreferedVersionHolderTable table."
|
|
INDEX { cucsControllerPreferedVersionHolderInstanceId }
|
|
::= { cucsControllerPreferedVersionHolderTable 1 }
|
|
|
|
CucsControllerPreferedVersionHolderEntry ::= SEQUENCE {
|
|
cucsControllerPreferedVersionHolderInstanceId CucsManagedObjectId,
|
|
cucsControllerPreferedVersionHolderDn CucsManagedObjectDn,
|
|
cucsControllerPreferedVersionHolderRn SnmpAdminString,
|
|
cucsControllerPreferedVersionHolderInUse TruthValue,
|
|
cucsControllerPreferedVersionHolderSerial SnmpAdminString
|
|
}
|
|
|
|
cucsControllerPreferedVersionHolderInstanceId OBJECT-TYPE
|
|
SYNTAX CucsManagedObjectId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instance identifier of the managed object."
|
|
::= { cucsControllerPreferedVersionHolderEntry 1 }
|
|
|
|
cucsControllerPreferedVersionHolderDn OBJECT-TYPE
|
|
SYNTAX CucsManagedObjectDn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:PreferedVersionHolder:dn
|
|
managed object property"
|
|
::= { cucsControllerPreferedVersionHolderEntry 2 }
|
|
|
|
cucsControllerPreferedVersionHolderRn OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:PreferedVersionHolder:rn
|
|
managed object property"
|
|
::= { cucsControllerPreferedVersionHolderEntry 3 }
|
|
|
|
cucsControllerPreferedVersionHolderInUse OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:PreferedVersionHolder:inUse
|
|
managed object property"
|
|
::= { cucsControllerPreferedVersionHolderEntry 4 }
|
|
|
|
cucsControllerPreferedVersionHolderSerial OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco UCS controller:PreferedVersionHolder:serial
|
|
managed object property"
|
|
::= { cucsControllerPreferedVersionHolderEntry 5 }
|
|
|
|
END
|