-- CISCO-PTP-MIB.my
|
|
--
|
|
-- August 2010, Vinay Shankarkumar
|
|
--
|
|
-- Copyright (c) 2010-2011-2020 by cisco Systems Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
|
|
CISCO-PTP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Integer32,
|
|
Gauge32,
|
|
Unsigned32,
|
|
Counter32,
|
|
Counter64,
|
|
NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
OBJECT-GROUP,
|
|
MODULE-COMPLIANCE,
|
|
NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION,
|
|
TruthValue,
|
|
DisplayString,
|
|
RowStatus
|
|
FROM SNMPv2-TC
|
|
InetAddressType,
|
|
InetAddress
|
|
FROM INET-ADDRESS-MIB
|
|
InterfaceIndexOrZero
|
|
FROM CISCO-TC
|
|
ciscoMgmt
|
|
FROM CISCO-SMI;
|
|
|
|
|
|
ciscoPtpMIB MODULE-IDENTITY
|
|
LAST-UPDATED "202003170000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
"Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: cs-<list>@cisco.com"
|
|
DESCRIPTION
|
|
"The MIB module for PTPv2 (IEEE1588 - 2008)
|
|
|
|
Overview of PTPv2 (IEEE 1588-2008)
|
|
|
|
This IEEE standard defines a protocol enabling precise
|
|
synchronization of clocks in measurement and control systems
|
|
implemented with packet-based networks, the IEEE Standard PTPv2
|
|
1588 (2008). This MIB does not address the standard IEEE
|
|
1588 (2002). The protocol is applicable to network elements
|
|
communicating using IP. The protocol enables heterogeneous
|
|
systems that include clocks of various inherent precision,
|
|
resolution, and stability to synchronize to a grandmaster
|
|
clock.
|
|
The protocol supports system-wide synchronization accuracy in
|
|
the sub-microsecond range with minimal network and local clock
|
|
computing resources. The standard uses UDP/IP. It includes
|
|
formal mechanisms for message extensions, higher sampling
|
|
rates, correction for asymmetry, a clock type to reduce error
|
|
accumulation in large topologies, and specifications on how to
|
|
incorporate the resulting additional data into the
|
|
synchronization protocol. The standard defines conformance and
|
|
management capability also.
|
|
|
|
MIB description
|
|
|
|
This MIB is to support the Precision Timing Protocol (PTP)
|
|
feature of Cisco System devices.
|
|
|
|
Acronyms:
|
|
ARB arbitrary
|
|
BMC best master clock
|
|
CAN Controller Area Network
|
|
CP Communication Profile
|
|
[according to IEC 61784-1:200710]
|
|
CPF Communication Profile Family
|
|
[according to IEC 61784-1:2007]
|
|
DS Differentiated Service
|
|
E2E End-to-End
|
|
E2ETC End-to-End Transparent Clock
|
|
EUI Extended Unique Identifier.
|
|
FFO Fractional Frequency Offset
|
|
GPS Global Positioning System
|
|
IANA Internet Assigned Numbers Authority
|
|
ICV Integrity Check Value
|
|
ID Identification
|
|
IPv4 Internet Protocol version 4
|
|
IPv6 Internet Protocol version 6
|
|
JD Julian Date
|
|
JDN Julian Day Number
|
|
MAC Media Access Control
|
|
[according to IEEE Std 802.3-2005]
|
|
MJD Modified Julian Day
|
|
NIST National Institute of Standards and
|
|
Technology (see www.nist.gov)
|
|
NTP Network Time Protocol (see IETF RFC 1305
|
|
[B7])
|
|
OUI Organizational Unique Identifier(allocated
|
|
by
|
|
the IEEE)
|
|
P2P Peer-to-Peer
|
|
P2PTC Peer-To-Peer Transparent Clock
|
|
PHY physical layer [according to IEEE Std
|
|
802.3-2005]
|
|
POSIX Portable Operating System Interface
|
|
(see ISO/IEC 9945:2003)
|
|
PPS Pulse per Second
|
|
PTP Precision Time Protocol
|
|
SA Security Associations
|
|
SNTP Simple Network Time Protocol
|
|
SOF Start of Frame
|
|
TAI International Atomic Time
|
|
TC Traffic Class
|
|
TC Transparent Clock
|
|
TLV Type, Length, Value [according to IEEE Std
|
|
802.1AB]
|
|
ToD Time of Day Synchronization
|
|
ToS Type of Service
|
|
UCMM UnConnect Message Manager
|
|
UDP/IP User Datagram Protocol
|
|
UTC Coordinated Universal Time
|
|
|
|
References:
|
|
[1] Precision clock synchronization protocol for networked
|
|
measurement and control systems - IEC 61588 IEEE 1588(tm)
|
|
Edition 2.0 2009-02
|
|
|
|
|
|
Definitions from [1] section 3.1
|
|
|
|
Accuracy:
|
|
The mean of the time or frequency error between the clock under
|
|
test and a perfect reference clock, over an ensemble of
|
|
measurements. Stability is a measure of how the mean varies
|
|
with respect to variables such as time, temperature, and so on.
|
|
|
|
The precision is a measure of the deviation of the error from
|
|
the mean.
|
|
|
|
Atomic process:
|
|
A process is atomic if the values of all inputs to the process
|
|
are not permitted to change until all of the results of the
|
|
process are instantiated, and the outputs of the process are
|
|
not visible to other processes until the processing of each
|
|
output is complete.
|
|
|
|
Boundary clock:
|
|
A clock that has multiple Precision Time Protocol(PTP) ports in
|
|
a domain and maintains the timescale used in the domain. It
|
|
may serve as the source of time, i.e., be a master clock, and
|
|
may synchronize to another clock, i.e., be a slave clock.
|
|
|
|
Boundary node clock:
|
|
A clock that has multiple Precision Time Protocol(PTP) ports in
|
|
a domain and maintains the timescale used in the domain. It
|
|
differs from the boundary clock in that the clock roles can
|
|
change.
|
|
|
|
Clock:
|
|
A node participating in the Precision Time Protocol (PTP) that
|
|
is capable of providing a measurement of the passage of time
|
|
since a defined epoch.
|
|
|
|
Domain:
|
|
A logical grouping of clocks that synchronize to each other
|
|
using the protocol, but that are not necessarily synchronized
|
|
to clocks in another domain.
|
|
|
|
End-to-end transparent clock:
|
|
A transparent clock that supports the use of the end-to-end
|
|
delay measurement mechanism between slave clocks and the master
|
|
clock. Each node must measure the residence time of PTP event
|
|
messages and accumulate it in Correction Field.
|
|
|
|
Epoch:
|
|
The origin of a timescale.
|
|
|
|
Event:
|
|
An abstraction of the mechanism by which signals or conditions
|
|
are generated and represented.
|
|
|
|
Foreign master:
|
|
An ordinary or boundary clock sending Announce messages to
|
|
another clock that is not the current master recognized by the
|
|
other clock.
|
|
|
|
Grandmaster clock:
|
|
Within a domain, a clock that is the ultimate source of time
|
|
for clock synchronization using the protocol.
|
|
|
|
Holdover:
|
|
A clock previously synchronized/syntonized to another clock
|
|
(normally a primary reference or a master clock) but now
|
|
free-running based on its own internal oscillator, whose
|
|
frequency is being adjusted using data acquired while it had
|
|
been synchronized/syntonized to the other clock. It is said to
|
|
be in holdover or in the holdover mode, as long as it is within
|
|
its accuracy requirements.
|
|
|
|
Link:
|
|
A network segment between two Precision Time Protocol ports
|
|
supporting the peer delay mechanism of this standard. The peer
|
|
delay mechanism is designed to measure the propagation time
|
|
over such a link.
|
|
|
|
Management node:
|
|
A device that configures and monitors clocks.
|
|
|
|
Master clock:
|
|
In the context of a single Precision Time Protocol
|
|
communication path, a clock that is the source of time to which
|
|
all other clocks on that path synchronize.
|
|
|
|
Message timestamp point:
|
|
A point within a Precision Time Protocol event message serving
|
|
as a reference point in the message. A timestamp is defined by
|
|
the instant a message timestamp point passes the reference
|
|
plane of a clock.
|
|
|
|
Multicast communication:
|
|
A communication model in which each Precision Time Protocol
|
|
message sent from any PTP port is capable of being received and
|
|
processed by all PTP ports on the same PTP communication path.
|
|
|
|
Node:
|
|
A device that can issue or receive Precision Time Protocol
|
|
communications on a network.
|
|
|
|
One-step clock:
|
|
A clock that provides time information using a single event
|
|
message.
|
|
|
|
On-pass support:
|
|
Indicates that each node in the synchronization chain from
|
|
master to slave can support IEEE-1588.
|
|
|
|
Ordinary clock:
|
|
A clock that has a single Precision Time Protocol port in a
|
|
domain and maintains the timescale used in the domain. It may
|
|
serve as a source of time, i.e., be a master clock, or may
|
|
synchronize to another clock, i.e., be a slave clock.
|
|
|
|
Parent clock:
|
|
The master clock to which a clock is synchronized.
|
|
|
|
|
|
Peer-to-peer transparent clock:
|
|
A transparent clock that, in addition to providing Precision
|
|
Time Protocol event transit time information, also provides
|
|
corrections for the propagation delay of the link connected to
|
|
the port receiving the PTP event message. In the presence of
|
|
peer-to-peer transparent clocks, delay measurements between
|
|
slave clocks and the master clock are performed using the
|
|
peer-to-peer delay measurement mechanism.
|
|
|
|
|
|
Phase change rate:
|
|
The observed rate of change in the measured time with respect
|
|
to the reference time. The phase change rate is equal to the
|
|
fractional frequency offset between the measured frequency and
|
|
the reference frequency.
|
|
|
|
PortNumber:
|
|
An index identifying a specific Precision Time Protocol port on
|
|
a PTP node.
|
|
|
|
Primary reference:
|
|
A source of time and or frequency that is traceable to
|
|
international standards.
|
|
|
|
Profile:
|
|
The set of allowed Precision Time Protocol features applicable
|
|
to a device.
|
|
|
|
Precision Time Protocol communication:
|
|
Information used in the operation of the protocol, transmitted
|
|
in a PTP message over a PTP communication path.
|
|
|
|
Precision Time Protocol communication path: The signaling path
|
|
portion of a particular network enabling direct communication
|
|
among ordinary and boundary clocks.
|
|
|
|
Precision Time Protocol node:
|
|
PTP ordinary, boundary, or transparent clock or a device that
|
|
generates or parses PTP messages.
|
|
|
|
Precision Time Protocol port:
|
|
A logical access point of a clock for PTP communications to the
|
|
communications network.
|
|
|
|
Recognized standard time source:
|
|
A recognized standard time source is a source external to
|
|
Precision Time Protocol that provides time and/or frequency as
|
|
appropriate that is traceable to the international standards
|
|
laboratories maintaining clocks that form the basis for the
|
|
International Atomic Time and Universal Coordinated Time
|
|
timescales. Examples of these are Global Positioning System,
|
|
NTP, and National Institute of Standards and Technology (NIST)
|
|
timeservers.
|
|
|
|
Requestor:
|
|
The port implementing the peer-to-peer delay mechanism that
|
|
initiates the mechanism by sending a Pdelay_Req message.
|
|
|
|
Responder:
|
|
The port responding to the receipt of a Pdelay_Req message as
|
|
part of the operation of the peer-to-peer delay mechanism.
|
|
|
|
Synchronized clocks:
|
|
Two clocks are synchronized to a specified uncertainty if they
|
|
have the same epoch and their measurements of the time of a
|
|
single event at an arbitrary time differ by no more than that
|
|
uncertainty.
|
|
|
|
Syntonized clocks:
|
|
Two clocks are syntonized if the duration of the second is the
|
|
same on both, which means the time as measured by each advances
|
|
at the same rate. They may or may not share the same epoch.
|
|
|
|
Time of Day:
|
|
|
|
|
|
Timeout:
|
|
A mechanism for terminating requested activity that, at least
|
|
from the requester's perspective, does not complete within the
|
|
specified time.
|
|
|
|
Timescale:
|
|
A linear measure of time from an epoch.
|
|
|
|
Traceability:
|
|
A property of the result of a measurement or the value of a
|
|
standard whereby it can be related to stated references,
|
|
usually national or international standards, through an unbroken
|
|
chain of comparisons all having stated uncertainties.
|
|
|
|
Translation device:
|
|
A boundary clock or, in some cases, a transparent clock that
|
|
translates the protocol messages between regions implementing
|
|
different transport and messaging protocols, between different
|
|
versions of IEEE Std 1588-2008/IEC 61588:2009, or different
|
|
Precision Time Protocol profiles.
|
|
|
|
transparent clock:
|
|
A device that measures the time taken for a Precision Time
|
|
Protocol event message to transit the device and provides this
|
|
information to clocks receiving this PTP event message.
|
|
|
|
Two-step clock:
|
|
A clock that provides time information using the combination of
|
|
an event message and a subsequent general message.
|
|
|
|
The below table specifies the object formats of the various
|
|
textual conventions used.
|
|
|
|
Data type mapping Textual Convention SYNTAX
|
|
-------------------- ------------------ ---------------------
|
|
5.3.2 TimeInterval ClockTimeInterval OCTET
|
|
STRING(SIZE(1..255))
|
|
5.3.3 Timestamp ClockTimestamp OCTET STRING(SIZE(6))
|
|
5.3.4 ClockIdentity ClockIdentity OCTET
|
|
STRING(SIZE(1..255))
|
|
5.3.5 PortIdentity ClockPortNumber INTEGER(1..65535)
|
|
5.3.7 ClockQuality ClockQualityClassType
|
|
|
|
Simple master-slave hierarchy [1] section 6.6.2.4
|
|
|
|
---------------
|
|
- Ordinary -
|
|
- Clock(1) -
|
|
- GrandMaster -
|
|
-------M-------
|
|
|
|
|
1
|
|
|
|
|
-------S-------------------------------
|
|
- Boundary -
|
|
- Clock(1) -
|
|
--------------M------------------M-----
|
|
| |
|
|
2 3
|
|
| |
|
|
-----S------ -------S------------------
|
|
- Ordinary - - Boundary -
|
|
- Clock(2) - - Clock(2) -
|
|
------------ -----M-------------M------
|
|
| |
|
|
4 5
|
|
| |
|
|
-----S------ -----S------
|
|
- Ordinary - - Ordinary -
|
|
- Clock(3) - - Clock(4) -
|
|
------------ ------------
|
|
|
|
Grandmaster
|
|
|
|
Boundary Clock(0-N) Ordinary Clocks(0-N)
|
|
Ordinary Clocks(0-N)
|
|
|
|
|
|
Relationship cardinality
|
|
PTP system 1 : N PTP Clock
|
|
PTP Clock 1 : 1 Domain
|
|
PTP Clock 1 : N PTP Ports
|
|
PTP Port N : N Physical Port (interface in IF-MIB)
|
|
|
|
Transparent clock diagram from section 6.7.1.3 of [1]
|
|
|
|
|
|
+----------------------------+
|
|
| Boundary clock - 1 |
|
|
+----------------------------+
|
|
| |
|
|
| |
|
|
+-- A --+ B
|
|
| |
|
|
+---------------------+ |
|
|
| Ordinary clock - 1| |
|
|
+---------------------+ |
|
|
+----------------------+
|
|
+--------------+ | End-to-end |
|
|
| Ordinary |------------------| transparent clock- |
|
|
| clock 1-1 | | 1 - 1 |
|
|
+--------------+ +----------------------+
|
|
|
|
|
|
|
|
C
|
|
|
|
|
|
|
|
+----------------------+
|
|
+--------------+ | End-to-end |
|
|
| Ordinary |------------------| transparent clock- |
|
|
| clock 1-2 | | 1 - 2 |
|
|
+--------------+ +----------------------+
|
|
|
|
|
|
The MIB refers to the sections of the IEEE 1588 standard for
|
|
reference. Throughout the MIB various secions from the standard
|
|
are referenced"
|
|
REVISION "202003170000Z"
|
|
DESCRIPTION
|
|
"Added a new MIB notification ciscoPtpMIBNotifyRogueMaster
|
|
for the new object cPtpClockRogueMasterDetect."
|
|
REVISION "202003160000Z"
|
|
DESCRIPTION
|
|
"Added the following objects to cPtpClockPortTable.
|
|
|
|
cPtpClockPortBlockGMC TruthValue
|
|
cPtpClockRogueMasterDetect TruthValue
|
|
|
|
Also modified the MIB conform group, ciscoPtpMIBClockPortGroup
|
|
for the new objects.
|
|
|
|
|
|
Added the following objects to the MIB
|
|
|
|
cPtpClockSystemTimePropertiesDomainIndex ClockDomainType
|
|
cPtpClockSystemTimePropertiesClockTypeIndex ClockType
|
|
cPtpClockSystemTimePropertiesInstanceIndex
|
|
ClockInstanceType
|
|
cPtpClockSystemTimePropertiesClockSyntonized TruthValue
|
|
cPtpClockSystemTimePropertiesDomainSyntonized TruthValue
|
|
cPtpClockSystemTimePropertiesFrequencyOffset Integer32
|
|
|
|
to cPtpClockSystemTimePropertiesTable.
|
|
|
|
Added a new MIB conform group,
|
|
ciscoPtpMIBClockSystemTimePropertiesGroup for the new objects.
|
|
|
|
Also modified the ciscoPtpMIBCompliances2 to add the new group
|
|
ciscoPtpMIBClockSystemTimePropertiesGroup."
|
|
REVISION "201908220000Z"
|
|
DESCRIPTION
|
|
"Version updating PTP notification objects."
|
|
::= { ciscoMgmt 760 }
|
|
|
|
|
|
|
|
ClockDomainType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Domain is identified by an integer, the domainNumber, in
|
|
the range of 0 to 255. An integer value that is used to assign
|
|
each PTP device to a particular domain. The following values
|
|
define the valid domains. [1] Section 7.1 Domains Table 2
|
|
|
|
Value definition.
|
|
--------- -------------------
|
|
0 Default domain
|
|
1 Alternate domain 1
|
|
2 Alternate domain 2
|
|
3 Alternate domain 3
|
|
4 - 127 User-defined domains
|
|
128 - 255 Reserved"
|
|
|
|
REFERENCE "Section 7.1 Domains and Table 2 of [1]"
|
|
SYNTAX Unsigned32 (0..255)
|
|
|
|
ClockIdentity ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clock Identity is an 8-octet array and will be presented in
|
|
the form of a character array. The value of the
|
|
ClockIdentity should be taken from the IEEE EUI-64 individual
|
|
assigned numbers as indicated in Section 7.5.2.2.2 of [1]. The
|
|
EUI-64 address is divided into the following fields.
|
|
|
|
OUI byte[0-2]
|
|
Extension identifier bytes:[3-7]
|
|
|
|
The clock identifier can be constructed from existing EUI-48
|
|
assignments and here is an abbreviated example extracted from
|
|
section 7.5.2.2.2 [1].
|
|
|
|
Company EUI-48 = 0xACDE4823456716
|
|
EUI-64 = ACDE48FFFE23456716
|
|
|
|
It is important to note the IEEE Registration Authority has
|
|
deprecated the use of MAC-48 in any new design."
|
|
|
|
REFERENCE "Section 7.5.2.2.1 from [1]"
|
|
SYNTAX OCTET STRING (SIZE (1..255))
|
|
|
|
ClockIntervalBase2 ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interval included in message types Announce, Sync,
|
|
Delay_Req, and Pdelay_Req as indicated in section 7.7.2.1 of
|
|
[1].
|
|
|
|
The mean time interval between successive messages shall be
|
|
represented as the logarithm to the base 2 of this time
|
|
interval measured in seconds on the local clock of the device
|
|
sending the message. The values of these logarithmic attributes
|
|
shall be selected from integers in the range -128 to 127 subject
|
|
to further limits established in an applicable PTP profile."
|
|
|
|
REFERENCE
|
|
"Section 7.7.2.1 General interval specification of [1]"
|
|
SYNTAX Integer32 (-128..127)
|
|
|
|
ClockMechanismType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clock type based on whether End to End or peer to peer
|
|
mechanisms are used. The mechanism used to calculate the Mean
|
|
Path Delay as indicated in Table 9 of IEEE 1588-2008.
|
|
|
|
Delay mechanism Value(hex) Specification
|
|
E2E 01 The port is configured to use
|
|
the delay request-response
|
|
mechanism.
|
|
|
|
P2P 02 The port is configured to use
|
|
the peer delay mechanism.
|
|
|
|
DISABLED FE The port does not implement
|
|
the delay mechanism."
|
|
|
|
REFERENCE "Sections 8.2.5.4.4, 6.6.4 and 7.4.2 of [1]."
|
|
SYNTAX INTEGER {
|
|
e2e(1),
|
|
p2p(2),
|
|
disabled(254)
|
|
}
|
|
|
|
ClockInstanceType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance of the Clock of a given clock type in a given
|
|
domain."
|
|
SYNTAX Unsigned32 (0..255)
|
|
|
|
ClockPortNumber ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index identifying a specific Precision Time Protocol (PTP)
|
|
port on a PTP node."
|
|
|
|
REFERENCE "Section 7.5.2.3 Port Number and 5.3.5 of [1]"
|
|
SYNTAX Unsigned32 (0..65535)
|
|
|
|
ClockPortState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the value of the current state of the protocol engine
|
|
associated with this port.
|
|
Port state Value Description
|
|
-----------------------------------------------------------
|
|
initializing 1 In this state a port initializes
|
|
its data sets, hardware, and
|
|
communication facilities.
|
|
faulty 2 The fault state of the protocol.
|
|
disabled 3 The port shall not place any
|
|
messages on its communication path.
|
|
listening 4 The port is waiting for the
|
|
announceReceiptTimeout to expire or
|
|
to receive an Announce message from
|
|
a master.
|
|
preMaster 5 The port shall behave in all respects
|
|
as though it were in the MASTER state
|
|
except that it shall not place any
|
|
messages on its communication path
|
|
except for Pdelay_Req, Pdelay_Resp,
|
|
Pdelay_Resp_Follow_Up, signaling, or
|
|
management messages.
|
|
master 6 The port is behaving as a master
|
|
port.
|
|
passive 7 The port shall not place any
|
|
messages on its communication path
|
|
except for Pdelay_Req, Pdelay_Resp,
|
|
Pdelay_Resp_Follow_Up, or signaling
|
|
messages, or management messages
|
|
that are a required response to
|
|
another management message
|
|
uncalibrated 8 The local port is preparing to
|
|
synchronize to the master port.
|
|
slave 9 The port is synchronizing to the
|
|
selected master port."
|
|
|
|
REFERENCE "Section 8.2.5.3.1 portState and 9.2.5 of [1]"
|
|
SYNTAX INTEGER {
|
|
initializing(1),
|
|
faulty(2),
|
|
disabled(3),
|
|
listening(4),
|
|
preMaster(5),
|
|
master(6),
|
|
passive(7),
|
|
uncalibrated(8),
|
|
slave(9)
|
|
}
|
|
|
|
ClockProfileType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock Profile used. From [1] section 3.1.30, Profile is the set
|
|
of allowed Precision Time Protocol (PTP) features applicable to
|
|
a device."
|
|
|
|
REFERENCE "Section 3.1.30 and 19.3 PTP profiles of [1]"
|
|
SYNTAX INTEGER {
|
|
default(1),
|
|
telecom(2),
|
|
vendorspecific(3)
|
|
}
|
|
|
|
ClockQualityAccuracyType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ClockQuality as specified in section 5.3.7, 7.6.2.5 and
|
|
Table 6 of [1].
|
|
|
|
The following values are not represented in the enumerated
|
|
values.
|
|
|
|
0x01-0x1F Reserved
|
|
0x32-0x7F Reserved
|
|
|
|
It is important to note that section 7.1.1 RFC2578 allows for
|
|
gaps and enumerate values to start with zero when indicated by
|
|
the protocol."
|
|
|
|
REFERENCE "Section 5.3.7, 7.6.2.5 and Table 6 of [1]"
|
|
SYNTAX INTEGER {
|
|
reserved00(1), -- 0
|
|
nanoSecond25(32), -- 0x20
|
|
nanoSecond100(33), -- 0x21
|
|
nanoSecond250(34), -- 0x22
|
|
microSec1(35), -- 0x23
|
|
microSec2dot5(36), -- 0x24
|
|
microSec10(37), -- 0x25
|
|
microSec25(38), -- 0x26
|
|
microSec100(39), -- 0x27
|
|
microSec250(40), -- 0x28
|
|
milliSec1(41), -- 0x29
|
|
milliSec2dot5(42), -- 0x2A
|
|
milliSec10(43), -- 0x2B
|
|
milliSec25(44), -- 0x2C
|
|
milliSec100(45), -- 0x2D
|
|
milliSec250(46), -- 0x2E
|
|
second1(47), -- 0x2F
|
|
second10(48), -- 0x30
|
|
secondGreater10(49), -- 0x31
|
|
unknown(254), -- 0xFE
|
|
reserved255(255) -- 0xFF
|
|
}
|
|
|
|
ClockQualityClassType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ClockQuality as specified in section 5.3.7, 7.6.2.4 and
|
|
Table 5 of [1].
|
|
|
|
Value Description
|
|
------
|
|
----------------------------------------------------------
|
|
0 Reserved to enable compatibility with future
|
|
versions.
|
|
1-5 Reserved
|
|
6 Shall designate a clock that is synchronized
|
|
to a primary reference time source. The
|
|
timescale distributed shall be PTP. A
|
|
clockClass 6 clock shall not be a slave to
|
|
another clock in the domain.
|
|
7 Shall designate a clock that has previously
|
|
been designated as clockClass 6 but that has
|
|
lost the ability to synchronize to a primary
|
|
reference time source and is in holdover mode
|
|
and within holdover specifications. The
|
|
timescale distributed shall be PTP. A
|
|
clockClass 7 clock shall not be a slave to
|
|
another clock in the domain.
|
|
8 Reserved.
|
|
9-10 Reserved to enable compatibility with future
|
|
versions.
|
|
11-12 Reserved.
|
|
13 Shall designate a clock that is synchronized
|
|
to an application-specific source of time.
|
|
The timescale distributed shall be ARB. A
|
|
clockClass 13 clock shall not be a slave to
|
|
another clock in the domain.
|
|
14 Shall designate a clock that has previously
|
|
been designated as clockClass 13 but that
|
|
has lost the ability to synchronize to an
|
|
application-specific source of time and is
|
|
in holdover mode and within holdover
|
|
specifications. The timescale distributed
|
|
shall be ARB. A clockClass 14 clock shall
|
|
not be a slave to another clock in the domain.
|
|
15-51 Reserved.
|
|
52 Degradation alternative A for a clock of
|
|
clockClass 7 that is not within holdover
|
|
specification. A clock of clockClass 52
|
|
shall not be a slave to another clock in
|
|
the domain.
|
|
53-57 Reserved.
|
|
58 Degradation alternative A for a clock of
|
|
clockClass 14 that is not within holdover
|
|
specification. A clock of clockClass 58 shall
|
|
not be a slave to another clock in the domain.
|
|
59-67 Reserved.
|
|
68-122 For use by alternate PTP profiles.
|
|
123-127 Reserved.
|
|
128-132 Reserved.
|
|
133-170 For use by alternate PTP profiles.
|
|
171-186 Reserved.
|
|
|
|
187 Degradation alternative B for a clock of
|
|
clockClass 7 that is not within holdover
|
|
specification. A clock of clockClass 187 may
|
|
be a slave to another clock in the domain.
|
|
188-192 Reserved.
|
|
193 Degradation alternative B for a clock of
|
|
clockClass 14 that is not within holdover
|
|
specification. A clock of clockClass 193 may
|
|
be a slave to another clock in the domain.
|
|
194-215 Reserved.
|
|
216-232 For use by alternate PTP profiles.
|
|
233-247 Reserved.
|
|
248 Default. This clockClass shall be used if
|
|
none of the other clockClass definitions apply.
|
|
249-250 Reserved.
|
|
251 Reserved for version 1 compatibility; see Clause 18.
|
|
252-254 Reserved.
|
|
255 Shall be the clockClass of a slave-only clock; see
|
|
9.2.2."
|
|
|
|
REFERENCE "section 5.3.7, 7.6.2.4 and Table 5 of [1]."
|
|
SYNTAX Unsigned32 (0..255)
|
|
|
|
ClockRoleType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Clock Role. The protocol generates a Master Slave
|
|
relationship among the clocks in the system.
|
|
|
|
Clock Role Value Description
|
|
--------------------------------------------------------------
|
|
Master clock 1 A clock that is the source of
|
|
time to which all other clocks on
|
|
that path synchronize.
|
|
|
|
Slave clock 2 A clock which synchronizes to
|
|
another clock (master)."
|
|
SYNTAX INTEGER {
|
|
master(1),
|
|
slave(2)
|
|
}
|
|
|
|
ClockStateType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clock state returned by PTP engine.
|
|
|
|
Clock State Value Description
|
|
--------------------------------------------------------------
|
|
Freerun state 1 Applies to a slave device that is not
|
|
locked to a master. This is the initial
|
|
state a slave starts out with when it
|
|
is not getting any PTP packets from the
|
|
master or because of some other input
|
|
error (erroneous packets, etc).
|
|
|
|
Holdover state 2 In this state the slave device is
|
|
locked to a master but communication
|
|
with the master is lost or the
|
|
timestamps in the ptp packets are
|
|
incorrect. But since the slave was
|
|
locked to the master, it can run with
|
|
the same accuracy for sometime. The
|
|
slave can continue to operate in this
|
|
state for some time. If communication
|
|
with the master is not restored for a
|
|
while, the device is moved to the
|
|
FREERUN state.
|
|
|
|
Acquiring state 3 The slave device is receiving packets
|
|
from a master and is trying to acquire
|
|
a lock.
|
|
|
|
Freq_locked state 4 Slave device is locked to the Master
|
|
with respect to frequency, but not phase
|
|
aligned
|
|
|
|
Phase_aligned state 5 Locked to the master with respect to
|
|
frequency and phase."
|
|
SYNTAX INTEGER {
|
|
freerun(1),
|
|
holdover(2),
|
|
acquiring(3),
|
|
frequencyLocked(4),
|
|
phaseAligned(5)
|
|
}
|
|
|
|
ClockTimeSourceType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ClockQuality as specified in section 5.3.7, 7.6.2.6 and
|
|
Table 7 of [1].
|
|
|
|
The following values are not represented in the enumerated
|
|
values.
|
|
|
|
0xF0-0xFE For use by alternate PTP profiles
|
|
0xFF Reserved
|
|
|
|
It is important to note that section 7.1.1 RFC2578 allows for
|
|
gaps and enumerate values to start with zero when indicated by
|
|
the protocol."
|
|
|
|
REFERENCE "section 5.3.7, 7.6.2.6 and Table 7 of [1]."
|
|
SYNTAX INTEGER {
|
|
atomicClock(16), -- 0x10
|
|
gps(32), -- 0x20
|
|
terrestrialRadio(48), -- 0x22
|
|
ptp(64), -- 0x40
|
|
ntp(80), -- 0x50
|
|
handSet(96), -- 0x60
|
|
other(144), -- 0x90
|
|
internalOsillator(160) -- 0xA0
|
|
}
|
|
|
|
ClockTimeInterval ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This textual convention corresponds to the TimeInterval
|
|
structure indicated in section 5.3.2 of [1]. It will be
|
|
presented in the form of a character array.
|
|
|
|
The TimeInterval type represents time intervals.
|
|
|
|
struct TimeInterval
|
|
{
|
|
Integer64 scaledNanoseconds;
|
|
};
|
|
|
|
The scaledNanoseconds member is the time interval expressed in
|
|
units of nanoseconds and multiplied by 2**16.
|
|
|
|
Positive or negative time intervals outside the maximum range
|
|
of this data type shall be encoded as the largest positive and
|
|
negative values of the data type, respectively.
|
|
|
|
For example, 2.5 ns is expressed as 0000 0000 0002 8000 in
|
|
Base16."
|
|
|
|
REFERENCE
|
|
"Section 5.3.2 and setion 7.7.2.1 Timer interval
|
|
specification of [1]"
|
|
SYNTAX OCTET STRING (SIZE (1..255))
|
|
|
|
ClockTxModeType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmission mode.
|
|
|
|
unicast. Using unicast commnuication channel.
|
|
|
|
multicast. Using Multicast communication channel.
|
|
|
|
multicast-mix. Using multicast-unicast communication channel"
|
|
SYNTAX INTEGER {
|
|
unicast(1),
|
|
multicast(2),
|
|
multicastmix(3)
|
|
}
|
|
|
|
ClockType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clock types as defined in the MIB module description."
|
|
|
|
REFERENCE "section 6.5.1 of [1]."
|
|
SYNTAX INTEGER {
|
|
ordinaryClock(1),
|
|
boundaryClock(2),
|
|
transparentClock(3),
|
|
boundaryNode(4)
|
|
}
|
|
ciscoPtpMIBNotifs OBJECT IDENTIFIER
|
|
::= { ciscoPtpMIB 0 }
|
|
|
|
ciscoPtpMIBObjects OBJECT IDENTIFIER
|
|
::= { ciscoPtpMIB 1 }
|
|
|
|
ciscoPtpMIBConformance OBJECT IDENTIFIER
|
|
::= { ciscoPtpMIB 2 }
|
|
|
|
ciscoPtpMIBSystemInfo OBJECT IDENTIFIER
|
|
::= { ciscoPtpMIBObjects 1 }
|
|
|
|
-- Conformance Information Definition
|
|
|
|
ciscoPtpMIBCompliances OBJECT IDENTIFIER
|
|
::= { ciscoPtpMIBConformance 1 }
|
|
|
|
|
|
ciscoPtpGMClockChange NOTIFICATION-TYPE
|
|
OBJECTS { cPtpClockParentDSGMClockIdentity }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ciscoPtpPGMClockChange notification is generated when the
|
|
value of cPtpClockParentDSGMClockIdentity is changed.
|
|
The Notification contains the PTP new grand master clock
|
|
identity."
|
|
::= { ciscoPtpMIBNotifs 1 }
|
|
|
|
ciscoPtpParentClockChange NOTIFICATION-TYPE
|
|
OBJECTS { cPtpClockParentDSParentPortIdentity }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ciscoPtpParentlockChange notification is generated when the
|
|
value of cPtpClockParentPortIdentity is changed.
|
|
The Notification contains PTP new parent clock identity and the
|
|
port
|
|
on which this is learnt."
|
|
::= { ciscoPtpMIBNotifs 2 }
|
|
|
|
ciscoPtpRogueMaster NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cPtpClockRogueMasterDetect,
|
|
cPtpClockPortName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ciscoPtpRogueMaster notification is generated when the
|
|
value of cPtpClockRogueMasterDetect is changed. This object
|
|
specifies the ptp rogue master detection on the port"
|
|
::= { ciscoPtpMIBNotifs 3 }
|
|
ciscoPtpMIBGroups OBJECT IDENTIFIER
|
|
::= { ciscoPtpMIBConformance 2 }
|
|
|
|
|
|
ciscoPtpMIBCompliances1 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Compliance statement for agents that provide read-only support
|
|
for CISCO-PTP-MIB. Such devices can only be monitored using this
|
|
MIB module.
|
|
|
|
The Module is implemented with support for read-only. In other
|
|
words, only monitoring is available by implementing this
|
|
MODULE-COMPLIANCE."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ciscoPtpMIBSystemInfoGroup }
|
|
::= { ciscoPtpMIBCompliances 1 }
|
|
|
|
ciscoPtpMIBCompliances2 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Compliance statement for agents that provide read-only support
|
|
for CISCO-PTP-MIB. Such devices can only be monitored using this
|
|
MIB module.
|
|
|
|
The Module is implemented with support for read-only. In other
|
|
words, only monitoring is available by implementing this
|
|
MODULE-COMPLIANCE."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
ciscoPtpMIBClockCurrentDSGroup,
|
|
ciscoPtpMIBClockParentDSGroup,
|
|
ciscoPtpMIBClockDefaultDSGroup,
|
|
ciscoPtpMIBClockRunningGroup,
|
|
ciscoPtpMIBClockTimepropertiesGroup,
|
|
ciscoPtpMIBClockSystemTimePropertiesGroup
|
|
}
|
|
::= { ciscoPtpMIBCompliances 2 }
|
|
|
|
ciscoPtpMIBCompliances3 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Compliance statement for agents that provide read-only support
|
|
for CISCO-PTP-MIB. Such devices can only be monitored using this
|
|
MIB module.
|
|
|
|
The Module is implemented with support for read-only. In other
|
|
words, only monitoring is available by implementing this
|
|
MODULE-COMPLIANCE."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
ciscoPtpMIBClockPortGroup,
|
|
ciscoPtpMIBClockPortDSGroup,
|
|
ciscoPtpMIBClockPortRunningGroup,
|
|
ciscoPtpMIBClockPortAssociateGroup
|
|
}
|
|
::= { ciscoPtpMIBCompliances 3 }
|
|
|
|
ciscoPtpMIBCompliances4 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Compliance statement for agents that provide read-only support
|
|
for CISCO-PTP-MIB. Such devices can only be monitored using this
|
|
MIB module.
|
|
|
|
The Module is implemented with support for read-only. In other
|
|
words, only monitoring is available by implementing this
|
|
MODULE-COMPLIANCE."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
ciscoPtpMIBClockTranparentDSGroup,
|
|
ciscoPtpMIBClockPortTransDSGroup
|
|
}
|
|
::= { ciscoPtpMIBCompliances 4 }
|
|
|
|
ciscoPtpMIBCompliances5 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Compliance statement for agents that provide read-only support
|
|
for CISCO-PTP-MIB. Such devices can only be monitored using this
|
|
MIB module.
|
|
|
|
The Module is implemented with support for read-only. In other
|
|
words, only monitoring is available by implementing this
|
|
MODULE-COMPLIANCE."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ciscoPtpMIBNotificationGroup }
|
|
::= { ciscoPtpMIBCompliances 5 }
|
|
|
|
ciscoPtpMIBSystemInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpSystemDomainTotals,
|
|
cPtpDomainClockPortsTotal,
|
|
cPtpDomainClockPortPhysicalInterfacesTotal,
|
|
cPtpClockInput1ppsEnabled,
|
|
cPtpClockOutput1ppsEnabled,
|
|
cPtpClockOutput1ppsOffsetEnabled,
|
|
cPtpClockInputFrequencyEnabled,
|
|
cPtpClockTODEnabled,
|
|
cPtpClockOutput1ppsOffsetValue,
|
|
cPtpClockOutput1ppsOffsetNegative,
|
|
cPtpSystemProfile,
|
|
cPtpClockInput1ppsInterface,
|
|
cPtpClockOutput1ppsInterface,
|
|
cPtpClockTODInterface
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing system-wide
|
|
information"
|
|
::= { ciscoPtpMIBGroups 1 }
|
|
|
|
ciscoPtpMIBClockCurrentDSGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockCurrentDSStepsRemoved,
|
|
cPtpClockCurrentDSOffsetFromMaster,
|
|
cPtpClockCurrentDSMeanPathDelay
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing PTP Current Dataset
|
|
information"
|
|
::= { ciscoPtpMIBGroups 2 }
|
|
|
|
ciscoPtpMIBClockParentDSGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockParentDSParentPortIdentity,
|
|
cPtpClockParentDSParentStats,
|
|
cPtpClockParentDSOffset,
|
|
cPtpClockParentDSClockPhChRate,
|
|
cPtpClockParentDSGMClockIdentity,
|
|
cPtpClockParentDSGMClockPriority1,
|
|
cPtpClockParentDSGMClockPriority2,
|
|
cPtpClockParentDSGMClockQualityClass,
|
|
cPtpClockParentDSGMClockQualityAccuracy,
|
|
cPtpClockParentDSGMClockQualityOffset
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing PTP Parent Dataset
|
|
information"
|
|
::= { ciscoPtpMIBGroups 3 }
|
|
|
|
ciscoPtpMIBClockDefaultDSGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockDefaultDSTwoStepFlag,
|
|
cPtpClockDefaultDSClockIdentity,
|
|
cPtpClockDefaultDSPriority1,
|
|
cPtpClockDefaultDSPriority2,
|
|
cPtpClockDefaultDSSlaveOnly,
|
|
cPtpClockDefaultDSQualityClass,
|
|
cPtpClockDefaultDSQualityAccuracy,
|
|
cPtpClockDefaultDSQualityOffset
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing PTP Default Dataset
|
|
information"
|
|
::= { ciscoPtpMIBGroups 4 }
|
|
|
|
ciscoPtpMIBClockRunningGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockRunningState,
|
|
cPtpClockRunningPacketsSent,
|
|
cPtpClockRunningPacketsReceived
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing PTP running state
|
|
information"
|
|
::= { ciscoPtpMIBGroups 5 }
|
|
|
|
ciscoPtpMIBClockTimepropertiesGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockTimePropertiesDSCurrentUTCOffsetValid,
|
|
cPtpClockTimePropertiesDSCurrentUTCOffset,
|
|
cPtpClockTimePropertiesDSLeap59,
|
|
cPtpClockTimePropertiesDSLeap61,
|
|
cPtpClockTimePropertiesDSTimeTraceable,
|
|
cPtpClockTimePropertiesDSFreqTraceable,
|
|
cPtpClockTimePropertiesDSPTPTimescale,
|
|
cPtpClockTimePropertiesDSSource
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing PTP Time Properties
|
|
information"
|
|
::= { ciscoPtpMIBGroups 6 }
|
|
|
|
ciscoPtpMIBClockTranparentDSGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockTransDefaultDSClockIdentity,
|
|
cPtpClockTransDefaultDSNumOfPorts,
|
|
cPtpClockTransDefaultDSDelay,
|
|
cPtpClockTransDefaultDSPrimaryDomain
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing PTP Transparent
|
|
Dataset
|
|
information"
|
|
::= { ciscoPtpMIBGroups 7 }
|
|
|
|
ciscoPtpMIBClockPortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockPortName,
|
|
cPtpClockPortSyncOneStep,
|
|
cPtpClockPortCurrentPeerAddress,
|
|
cPtpClockPortNumOfAssociatedPorts,
|
|
cPtpClockPortCurrentPeerAddressType,
|
|
cPtpClockPortRole,
|
|
cPtpClockPortBlockGMC,
|
|
cPtpClockRogueMasterDetect
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing information for a
|
|
given PTP Port."
|
|
::= { ciscoPtpMIBGroups 8 }
|
|
|
|
ciscoPtpMIBClockPortDSGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockPortDSName,
|
|
cPtpClockPortDSPortIdentity,
|
|
cPtpClockPortDSAnnouncementInterval,
|
|
cPtpClockPortDSAnnounceRctTimeout,
|
|
cPtpClockPortDSSyncInterval,
|
|
cPtpClockPortDSMinDelayReqInterval,
|
|
cPtpClockPortDSPeerDelayReqInterval,
|
|
cPtpClockPortDSDelayMech,
|
|
cPtpClockPortDSPeerMeanPathDelay,
|
|
cPtpClockPortDSGrantDuration,
|
|
cPtpClockPortDSPTPVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing PTP Port Dataset
|
|
information"
|
|
::= { ciscoPtpMIBGroups 9 }
|
|
|
|
ciscoPtpMIBClockPortRunningGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockPortRunningName,
|
|
cPtpClockPortRunningState,
|
|
cPtpClockPortRunningRole,
|
|
cPtpClockPortRunningInterfaceIndex,
|
|
cPtpClockPortRunningIPversion,
|
|
cPtpClockPortRunningEncapsulationType,
|
|
cPtpClockPortRunningTxMode,
|
|
cPtpClockPortRunningRxMode,
|
|
cPtpClockPortRunningPacketsReceived,
|
|
cPtpClockPortRunningPacketsSent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing PTP running interface
|
|
information"
|
|
::= { ciscoPtpMIBGroups 10 }
|
|
|
|
ciscoPtpMIBClockPortTransDSGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockPortTransDSPortIdentity,
|
|
cPtpClockPortTransDSlogMinPdelayReqInt,
|
|
cPtpClockPortTransDSFaultyFlag,
|
|
cPtpClockPortTransDSPeerMeanPathDelay
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing PTP TransparentDS
|
|
Dataset
|
|
information"
|
|
::= { ciscoPtpMIBGroups 11 }
|
|
|
|
ciscoPtpMIBClockPortAssociateGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockPortAssociatePacketsSent,
|
|
cPtpClockPortAssociatePacketsReceived,
|
|
cPtpClockPortAssociateAddress,
|
|
cPtpClockPortAssociateAddressType,
|
|
cPtpClockPortAssociateInErrors,
|
|
cPtpClockPortAssociateOutErrors
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing information on peer
|
|
PTP ports for a given PTP clock-port."
|
|
::= { ciscoPtpMIBGroups 12 }
|
|
|
|
ciscoPtpMIBNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
ciscoPtpParentClockChange,
|
|
ciscoPtpGMClockChange
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing information of PTP
|
|
notifications for changes
|
|
in PTP parent clock and grand master clock."
|
|
::= { ciscoPtpMIBGroups 13 }
|
|
|
|
ciscoPtpMIBClockSystemTimePropertiesGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cPtpClockSystemTimePropertiesClockSyntonized,
|
|
cPtpClockSystemTimePropertiesDomainSyntonized,
|
|
cPtpClockSystemTimePropertiesFrequencyOffset
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group which aggregates objects describing PTP Time Properties
|
|
information."
|
|
::= { ciscoPtpMIBGroups 14 }
|
|
ciscoPtpMIBClockInfo OBJECT IDENTIFIER
|
|
::= { ciscoPtpMIBObjects 2 }
|
|
|
|
|
|
cPtpSystemTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpSystemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of count information about the PTP system for all
|
|
domains."
|
|
::= { ciscoPtpMIBSystemInfo 1 }
|
|
|
|
cPtpSystemEntry OBJECT-TYPE
|
|
SYNTAX CPtpSystemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing count information about a
|
|
single domain. New row entries are added when the PTP clock for
|
|
this domain is configured, while the unconfiguration of the PTP
|
|
clock removes it."
|
|
INDEX {
|
|
cPtpDomainIndex,
|
|
cPtpInstanceIndex
|
|
}
|
|
::= { cPtpSystemTable 1 }
|
|
|
|
CPtpSystemEntry ::= SEQUENCE {
|
|
cPtpDomainIndex ClockDomainType,
|
|
cPtpInstanceIndex ClockInstanceType,
|
|
cPtpDomainClockPortsTotal Gauge32,
|
|
cPtpDomainClockPortPhysicalInterfacesTotal Gauge32
|
|
}
|
|
|
|
cPtpDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices. The Clock Domain is a logical group of
|
|
clocks and devices that synchronize with each other using the
|
|
PTP protocol.
|
|
|
|
|
|
0 Default domain
|
|
1 Alternate domain 1
|
|
2 Alternate domain 2
|
|
3 Alternate domain 3
|
|
4 - 127 User-defined domains
|
|
128 - 255 Reserved"
|
|
::= { cPtpSystemEntry 1 }
|
|
|
|
cPtpInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the Clock for this
|
|
domain."
|
|
::= { cPtpSystemEntry 2 }
|
|
|
|
cPtpDomainClockPortsTotal OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "ptp ports"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the total number of clock ports
|
|
configured within a domain."
|
|
::= { cPtpSystemEntry 3 }
|
|
|
|
cPtpDomainClockPortPhysicalInterfacesTotal OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "physical ports"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the total number of clock port Physical
|
|
interfaces configured within a domain instance for PTP
|
|
communications."
|
|
::= { cPtpSystemEntry 4 }
|
|
|
|
|
|
|
|
cPtpSystemDomainTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpSystemDomainEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP system for all clock modes
|
|
-- ordinary, boundary or transparent."
|
|
::= { ciscoPtpMIBSystemInfo 2 }
|
|
|
|
cPtpSystemDomainEntry OBJECT-TYPE
|
|
SYNTAX CPtpSystemDomainEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
clock mode for the PTP system. A row entry gets added when PTP
|
|
clocks are configured on the router."
|
|
INDEX { cPtpSystemDomainClockTypeIndex }
|
|
::= { cPtpSystemDomainTable 1 }
|
|
|
|
CPtpSystemDomainEntry ::= SEQUENCE {
|
|
cPtpSystemDomainClockTypeIndex ClockType,
|
|
cPtpSystemDomainTotals Gauge32
|
|
}
|
|
|
|
cPtpSystemDomainClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the
|
|
Textual convention description."
|
|
::= { cPtpSystemDomainEntry 1 }
|
|
|
|
cPtpSystemDomainTotals OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "domains"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the total number of PTP domains for this
|
|
particular clock type configured in this node."
|
|
::= { cPtpSystemDomainEntry 2 }
|
|
|
|
|
|
|
|
cPtpClockNodeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockNodeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP system for a given domain."
|
|
::= { ciscoPtpMIBSystemInfo 3 }
|
|
|
|
cPtpClockNodeEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockNodeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
domain. A entry is added when a new PTP clock domain is
|
|
configured on the router."
|
|
INDEX {
|
|
cPtpClockDomainIndex,
|
|
cPtpClockTypeIndex,
|
|
cPtpClockInstanceIndex
|
|
}
|
|
::= { cPtpClockNodeTable 1 }
|
|
|
|
CPtpClockNodeEntry ::= SEQUENCE {
|
|
cPtpClockDomainIndex ClockDomainType,
|
|
cPtpClockTypeIndex ClockType,
|
|
cPtpClockInstanceIndex ClockInstanceType,
|
|
cPtpClockInput1ppsEnabled TruthValue,
|
|
cPtpClockInputFrequencyEnabled TruthValue,
|
|
cPtpClockTODEnabled TruthValue,
|
|
cPtpClockOutput1ppsEnabled TruthValue,
|
|
cPtpClockOutput1ppsOffsetEnabled TruthValue,
|
|
cPtpClockOutput1ppsOffsetValue Unsigned32,
|
|
cPtpClockOutput1ppsOffsetNegative TruthValue,
|
|
cPtpClockInput1ppsInterface DisplayString,
|
|
cPtpClockOutput1ppsInterface DisplayString,
|
|
cPtpClockTODInterface DisplayString
|
|
}
|
|
|
|
cPtpClockDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockNodeEntry 1 }
|
|
|
|
cPtpClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the
|
|
Textual convention description."
|
|
::= { cPtpClockNodeEntry 2 }
|
|
|
|
cPtpClockInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the Clock for this clock
|
|
type for the given domain."
|
|
::= { cPtpClockNodeEntry 3 }
|
|
|
|
cPtpClockInput1ppsEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether the node is enabled for PTP input
|
|
clocking using the 1pps interface."
|
|
::= { cPtpClockNodeEntry 4 }
|
|
|
|
cPtpClockInputFrequencyEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether enabled for Frequency input using
|
|
the 1.544 Mhz, 2.048 Mhz, or 10Mhz timing interface."
|
|
::= { cPtpClockNodeEntry 5 }
|
|
|
|
cPtpClockTODEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether the node is enabled for TOD."
|
|
::= { cPtpClockNodeEntry 6 }
|
|
|
|
cPtpClockOutput1ppsEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether the node is enabled for PTP input
|
|
clocking using the 1pps interface."
|
|
::= { cPtpClockNodeEntry 7 }
|
|
|
|
cPtpClockOutput1ppsOffsetEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether an offset is configured in order
|
|
to compensate for a known phase error such as network
|
|
asymmetry."
|
|
REFERENCE
|
|
"section 11 Clock offset, path delay, residence time, and
|
|
asymmetry corrections of [1]"
|
|
::= { cPtpClockNodeEntry 8 }
|
|
|
|
cPtpClockOutput1ppsOffsetValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the fixed offset value configured to be
|
|
added for the 1pps output."
|
|
::= { cPtpClockNodeEntry 9 }
|
|
|
|
cPtpClockOutput1ppsOffsetNegative OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether the added (fixed) offset to the
|
|
1pps output is negative or not. When object returns TRUE the
|
|
offset is negative and when object returns FALSE the offset is
|
|
positive."
|
|
::= { cPtpClockNodeEntry 10 }
|
|
|
|
cPtpClockInput1ppsInterface OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the 1pps interface used for PTP input
|
|
clocking."
|
|
::= { cPtpClockNodeEntry 11 }
|
|
|
|
cPtpClockOutput1ppsInterface OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the 1pps interface used for PTP output
|
|
clocking."
|
|
::= { cPtpClockNodeEntry 12 }
|
|
|
|
cPtpClockTODInterface OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the interface used for PTP TOD."
|
|
::= { cPtpClockNodeEntry 13 }
|
|
|
|
|
|
|
|
cPtpSystemProfile OBJECT-TYPE
|
|
SYNTAX ClockProfileType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP Profile implemented on the
|
|
system."
|
|
REFERENCE "Section 19.3 PTP profiles of [1]"
|
|
::= { ciscoPtpMIBSystemInfo 4 }
|
|
|
|
cPtpClockCurrentDSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockCurrentDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP clock Current Datasets for
|
|
all domains."
|
|
::= { ciscoPtpMIBClockInfo 1 }
|
|
|
|
cPtpClockCurrentDSEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockCurrentDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
PTP clock Current Datasets for a domain."
|
|
REFERENCE
|
|
"1588 Version 2.0 Section 8.2.2 currentDS data set member
|
|
specifications of [1]"
|
|
INDEX {
|
|
cPtpClockCurrentDSDomainIndex,
|
|
cPtpClockCurrentDSClockTypeIndex,
|
|
cPtpClockCurrentDSInstanceIndex
|
|
}
|
|
::= { cPtpClockCurrentDSTable 1 }
|
|
|
|
CPtpClockCurrentDSEntry ::= SEQUENCE {
|
|
cPtpClockCurrentDSDomainIndex ClockDomainType,
|
|
cPtpClockCurrentDSClockTypeIndex ClockType,
|
|
cPtpClockCurrentDSInstanceIndex ClockInstanceType,
|
|
cPtpClockCurrentDSStepsRemoved Counter32,
|
|
cPtpClockCurrentDSOffsetFromMaster ClockTimeInterval,
|
|
cPtpClockCurrentDSMeanPathDelay ClockTimeInterval
|
|
}
|
|
|
|
cPtpClockCurrentDSDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockCurrentDSEntry 1 }
|
|
|
|
cPtpClockCurrentDSClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the
|
|
Textual convention description."
|
|
::= { cPtpClockCurrentDSEntry 2 }
|
|
|
|
cPtpClockCurrentDSInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockCurrentDSEntry 3 }
|
|
|
|
cPtpClockCurrentDSStepsRemoved OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "steps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current clock dataset StepsRemoved value.
|
|
|
|
This object specifies the distance measured by the number of
|
|
Boundary clocks between the local clock and the Foreign master
|
|
as indicated in the stepsRemoved field of Announce messages."
|
|
REFERENCE "1588 Version 2.0 Section 8.2.2.2 stepsRemoved"
|
|
::= { cPtpClockCurrentDSEntry 4 }
|
|
|
|
cPtpClockCurrentDSOffsetFromMaster OBJECT-TYPE
|
|
SYNTAX ClockTimeInterval
|
|
UNITS "Time Interval"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the current clock dataset ClockOffset
|
|
value. The value of the computation of the offset in time
|
|
between
|
|
a slave and a master clock."
|
|
REFERENCE "1588 Version 2.0 Section 8.2.2.3 of [1]"
|
|
::= { cPtpClockCurrentDSEntry 5 }
|
|
|
|
cPtpClockCurrentDSMeanPathDelay OBJECT-TYPE
|
|
SYNTAX ClockTimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the current clock dataset
|
|
MeanPathDelay value.
|
|
|
|
The mean path delay between a pair of ports as measure by the
|
|
delay request-response mechanism."
|
|
REFERENCE "1588 Version 2.0 Section 8.2.2.4 mean path delay"
|
|
::= { cPtpClockCurrentDSEntry 6 }
|
|
|
|
|
|
|
|
cPtpClockParentDSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockParentDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP clock Parent Datasets for
|
|
all domains."
|
|
::= { ciscoPtpMIBClockInfo 2 }
|
|
|
|
cPtpClockParentDSEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockParentDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
PTP clock Parent Datasets for a domain."
|
|
REFERENCE
|
|
"Section 8.2.3 parentDS data set member specifications of
|
|
[1]"
|
|
INDEX {
|
|
cPtpClockParentDSDomainIndex,
|
|
cPtpClockParentDSClockTypeIndex,
|
|
cPtpClockParentDSInstanceIndex
|
|
}
|
|
::= { cPtpClockParentDSTable 1 }
|
|
|
|
CPtpClockParentDSEntry ::= SEQUENCE {
|
|
cPtpClockParentDSDomainIndex ClockDomainType,
|
|
cPtpClockParentDSClockTypeIndex ClockType,
|
|
cPtpClockParentDSInstanceIndex ClockInstanceType,
|
|
cPtpClockParentDSParentPortIdentity OCTET STRING,
|
|
cPtpClockParentDSParentStats TruthValue,
|
|
cPtpClockParentDSOffset ClockIntervalBase2,
|
|
cPtpClockParentDSClockPhChRate Integer32,
|
|
cPtpClockParentDSGMClockIdentity ClockIdentity,
|
|
cPtpClockParentDSGMClockPriority1 Integer32,
|
|
cPtpClockParentDSGMClockPriority2 Integer32,
|
|
cPtpClockParentDSGMClockQualityClass ClockQualityClassType,
|
|
cPtpClockParentDSGMClockQualityAccuracy ClockQualityAccuracyType,
|
|
cPtpClockParentDSGMClockQualityOffset Unsigned32
|
|
}
|
|
|
|
cPtpClockParentDSDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockParentDSEntry 1 }
|
|
|
|
cPtpClockParentDSClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the
|
|
Textual convention description."
|
|
::= { cPtpClockParentDSEntry 2 }
|
|
|
|
cPtpClockParentDSInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockParentDSEntry 3 }
|
|
|
|
cPtpClockParentDSParentPortIdentity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the value of portIdentity of the port on
|
|
the master that issues the Sync messages used in synchronizing
|
|
this clock."
|
|
REFERENCE
|
|
"section 8.2.3.2 parentDS.parentPortIdentity of [1]"
|
|
::= { cPtpClockParentDSEntry 4 }
|
|
|
|
cPtpClockParentDSParentStats OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Parent Dataset ParentStats value.
|
|
|
|
This value indicates whether the values of ParentDSOffset
|
|
and ParentDSClockPhChRate have been measured and are valid.
|
|
A TRUE value shall indicate valid data."
|
|
REFERENCE "section 8.2.3.3 parentDS.parentStats of [1]"
|
|
::= { cPtpClockParentDSEntry 5 }
|
|
|
|
cPtpClockParentDSOffset OBJECT-TYPE
|
|
SYNTAX ClockIntervalBase2 (-128..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Parent Dataset
|
|
ParentOffsetScaledLogVariance value.
|
|
|
|
This value is the variance of the parent clocks phase as
|
|
measured by the local clock."
|
|
REFERENCE
|
|
"section 8.2.3.4
|
|
parentDS.observedParentOffsetScaledLogVariance [1]"
|
|
::= { cPtpClockParentDSEntry 6 }
|
|
|
|
cPtpClockParentDSClockPhChRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock's parent dataset
|
|
ParentClockPhaseChangeRate value.
|
|
|
|
This value is an estimate of the parent clocks phase change
|
|
rate as measured by the slave clock."
|
|
REFERENCE
|
|
"section 8.2.3.5
|
|
parentDS.observedParentClockPhaseChangeRate of [1]"
|
|
::= { cPtpClockParentDSEntry 7 }
|
|
|
|
cPtpClockParentDSGMClockIdentity OBJECT-TYPE
|
|
SYNTAX ClockIdentity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the parent dataset Grandmaster clock
|
|
identity."
|
|
REFERENCE
|
|
"section 8.2.3.6 parentDS.grandmasterIdentity of [1]"
|
|
::= { cPtpClockParentDSEntry 8 }
|
|
|
|
cPtpClockParentDSGMClockPriority1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the parent dataset Grandmaster clock
|
|
priority1."
|
|
REFERENCE
|
|
"section 8.2.3.8 parentDS.grandmasterPriority1 of [1]"
|
|
::= { cPtpClockParentDSEntry 9 }
|
|
|
|
cPtpClockParentDSGMClockPriority2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the parent dataset grandmaster clock
|
|
priority2."
|
|
REFERENCE
|
|
"section 8.2.3.9 parentDS.grandmasterPriority2 of [1]"
|
|
::= { cPtpClockParentDSEntry 10 }
|
|
|
|
cPtpClockParentDSGMClockQualityClass OBJECT-TYPE
|
|
SYNTAX ClockQualityClassType (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the parent dataset grandmaster clock
|
|
quality class."
|
|
REFERENCE
|
|
"section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
|
|
::= { cPtpClockParentDSEntry 11 }
|
|
|
|
cPtpClockParentDSGMClockQualityAccuracy OBJECT-TYPE
|
|
SYNTAX ClockQualityAccuracyType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the parent dataset grandmaster clock
|
|
quality accuracy."
|
|
REFERENCE
|
|
"section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
|
|
::= { cPtpClockParentDSEntry 12 }
|
|
|
|
cPtpClockParentDSGMClockQualityOffset OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the parent dataset grandmaster clock
|
|
quality offset."
|
|
REFERENCE
|
|
"section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
|
|
::= { cPtpClockParentDSEntry 13 }
|
|
|
|
|
|
|
|
cPtpClockDefaultDSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockDefaultDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP clock Default Datasets for
|
|
all domains."
|
|
::= { ciscoPtpMIBClockInfo 3 }
|
|
|
|
cPtpClockDefaultDSEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockDefaultDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
PTP clock Default Datasets for a domain."
|
|
INDEX {
|
|
cPtpClockDefaultDSDomainIndex,
|
|
cPtpClockDefaultDSClockTypeIndex,
|
|
cPtpClockDefaultDSInstanceIndex
|
|
}
|
|
::= { cPtpClockDefaultDSTable 1 }
|
|
|
|
CPtpClockDefaultDSEntry ::= SEQUENCE {
|
|
cPtpClockDefaultDSDomainIndex ClockDomainType,
|
|
cPtpClockDefaultDSClockTypeIndex ClockType,
|
|
cPtpClockDefaultDSInstanceIndex ClockInstanceType,
|
|
cPtpClockDefaultDSTwoStepFlag TruthValue,
|
|
cPtpClockDefaultDSClockIdentity ClockIdentity,
|
|
cPtpClockDefaultDSPriority1 Integer32,
|
|
cPtpClockDefaultDSPriority2 Integer32,
|
|
cPtpClockDefaultDSSlaveOnly TruthValue,
|
|
cPtpClockDefaultDSQualityClass ClockQualityClassType,
|
|
cPtpClockDefaultDSQualityAccuracy ClockQualityAccuracyType,
|
|
cPtpClockDefaultDSQualityOffset Integer32
|
|
}
|
|
|
|
cPtpClockDefaultDSDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockDefaultDSEntry 1 }
|
|
|
|
cPtpClockDefaultDSClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the
|
|
Textual convention description."
|
|
::= { cPtpClockDefaultDSEntry 2 }
|
|
|
|
cPtpClockDefaultDSInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockDefaultDSEntry 3 }
|
|
|
|
cPtpClockDefaultDSTwoStepFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether the Two Step process is used."
|
|
::= { cPtpClockDefaultDSEntry 4 }
|
|
|
|
cPtpClockDefaultDSClockIdentity OBJECT-TYPE
|
|
SYNTAX ClockIdentity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the default Datasets clock identity."
|
|
::= { cPtpClockDefaultDSEntry 5 }
|
|
|
|
cPtpClockDefaultDSPriority1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the default Datasets clock Priority1."
|
|
::= { cPtpClockDefaultDSEntry 6 }
|
|
|
|
cPtpClockDefaultDSPriority2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the default Datasets clock Priority2."
|
|
::= { cPtpClockDefaultDSEntry 7 }
|
|
|
|
cPtpClockDefaultDSSlaveOnly OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether the SlaveOnly flag is set."
|
|
::= { cPtpClockDefaultDSEntry 8 }
|
|
|
|
cPtpClockDefaultDSQualityClass OBJECT-TYPE
|
|
SYNTAX ClockQualityClassType (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the default dataset Quality Class."
|
|
::= { cPtpClockDefaultDSEntry 9 }
|
|
|
|
cPtpClockDefaultDSQualityAccuracy OBJECT-TYPE
|
|
SYNTAX ClockQualityAccuracyType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the default dataset Quality Accurarcy."
|
|
::= { cPtpClockDefaultDSEntry 10 }
|
|
|
|
cPtpClockDefaultDSQualityOffset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the default dataset Quality offset."
|
|
::= { cPtpClockDefaultDSEntry 11 }
|
|
|
|
|
|
|
|
cPtpClockRunningTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockRunningEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP clock Running Datasets for
|
|
all domains."
|
|
::= { ciscoPtpMIBClockInfo 4 }
|
|
|
|
cPtpClockRunningEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockRunningEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
PTP clock running Datasets for a domain."
|
|
INDEX {
|
|
cPtpClockRunningDomainIndex,
|
|
cPtpClockRunningClockTypeIndex,
|
|
cPtpClockRunningInstanceIndex
|
|
}
|
|
::= { cPtpClockRunningTable 1 }
|
|
|
|
CPtpClockRunningEntry ::= SEQUENCE {
|
|
cPtpClockRunningDomainIndex ClockDomainType,
|
|
cPtpClockRunningClockTypeIndex ClockType,
|
|
cPtpClockRunningInstanceIndex ClockInstanceType,
|
|
cPtpClockRunningState ClockStateType,
|
|
cPtpClockRunningPacketsSent Counter64,
|
|
cPtpClockRunningPacketsReceived Counter64
|
|
}
|
|
|
|
cPtpClockRunningDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockRunningEntry 1 }
|
|
|
|
cPtpClockRunningClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the
|
|
Textual convention description."
|
|
::= { cPtpClockRunningEntry 2 }
|
|
|
|
cPtpClockRunningInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockRunningEntry 3 }
|
|
|
|
cPtpClockRunningState OBJECT-TYPE
|
|
SYNTAX ClockStateType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Clock state returned by PTP engine
|
|
which was described earlier.
|
|
|
|
Freerun state. Applies to a slave device that is not locked to
|
|
a master. This is the initial state a slave starts out with
|
|
when
|
|
it is not getting any PTP packets from the master or because of
|
|
some other input error (erroneous packets, etc).
|
|
|
|
Holdover state. In this state the slave device is locked to a
|
|
master but communication with the master is lost or the
|
|
timestamps in the ptp packets are incorrect. But since the
|
|
slave was locked to the master, it can run with the same
|
|
accuracy for
|
|
sometime. The slave can continue to operate in this state for
|
|
some time. If communication with the master is not restored for
|
|
a while, the device is moved to the FREERUN state.
|
|
|
|
Acquiring state. The slave device is receiving packets from a
|
|
master and is trying to acquire a lock.
|
|
|
|
Freq_locked state. Slave device is locked to the Master with
|
|
respect to frequency, but not phase aligned
|
|
|
|
Phase_aligned state. Locked to the master with respect to
|
|
frequency and phase."
|
|
::= { cPtpClockRunningEntry 4 }
|
|
|
|
cPtpClockRunningPacketsSent OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the total number of all packet Unicast
|
|
and multicast that have been sent out for this clock in this
|
|
domain for this type."
|
|
::= { cPtpClockRunningEntry 5 }
|
|
|
|
cPtpClockRunningPacketsReceived OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the total number of all packet Unicast
|
|
and multicast that have been received for this clock in this
|
|
domain for this type."
|
|
::= { cPtpClockRunningEntry 6 }
|
|
|
|
|
|
|
|
cPtpClockTimePropertiesDSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockTimePropertiesDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP clock Timeproperties
|
|
Datasets for all domains."
|
|
::= { ciscoPtpMIBClockInfo 5 }
|
|
|
|
cPtpClockTimePropertiesDSEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockTimePropertiesDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
PTP clock timeproperties Datasets for a domain."
|
|
REFERENCE "Section 8.2.4 of [1]"
|
|
INDEX {
|
|
cPtpClockTimePropertiesDSDomainIndex,
|
|
cPtpClockTimePropertiesDSClockTypeIndex,
|
|
cPtpClockTimePropertiesDSInstanceIndex
|
|
}
|
|
::= { cPtpClockTimePropertiesDSTable 1 }
|
|
|
|
CPtpClockTimePropertiesDSEntry ::= SEQUENCE {
|
|
cPtpClockTimePropertiesDSDomainIndex ClockDomainType,
|
|
cPtpClockTimePropertiesDSClockTypeIndex ClockType,
|
|
cPtpClockTimePropertiesDSInstanceIndex ClockInstanceType,
|
|
cPtpClockTimePropertiesDSCurrentUTCOffsetValid TruthValue,
|
|
cPtpClockTimePropertiesDSCurrentUTCOffset Integer32,
|
|
cPtpClockTimePropertiesDSLeap59 TruthValue,
|
|
cPtpClockTimePropertiesDSLeap61 TruthValue,
|
|
cPtpClockTimePropertiesDSTimeTraceable TruthValue,
|
|
cPtpClockTimePropertiesDSFreqTraceable TruthValue,
|
|
cPtpClockTimePropertiesDSPTPTimescale TruthValue,
|
|
cPtpClockTimePropertiesDSSource ClockTimeSourceType
|
|
}
|
|
|
|
cPtpClockTimePropertiesDSDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockTimePropertiesDSEntry 1 }
|
|
|
|
cPtpClockTimePropertiesDSClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the
|
|
Textual convention description."
|
|
::= { cPtpClockTimePropertiesDSEntry 2 }
|
|
|
|
cPtpClockTimePropertiesDSInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockTimePropertiesDSEntry 3 }
|
|
|
|
cPtpClockTimePropertiesDSCurrentUTCOffsetValid OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the timeproperties dataset value of
|
|
whether current UTC offset is valid."
|
|
REFERENCE "Section 8.2.4.2 of [1]"
|
|
::= { cPtpClockTimePropertiesDSEntry 4 }
|
|
|
|
cPtpClockTimePropertiesDSCurrentUTCOffset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the timeproperties dataset value of
|
|
current UTC offset.
|
|
|
|
In PTP systems whose epoch is the PTP epoch, the value of
|
|
timePropertiesDS.currentUtcOffset is the offset
|
|
between TAI and UTC; otherwise the value has no meaning. The
|
|
value shall be in units of seconds.
|
|
The initialization value shall be selected as follows:
|
|
a) If the timePropertiesDS.ptpTimescale (see 8.2.4.8) is TRUE,
|
|
the value is the value obtained from a
|
|
primary reference if the value is known at the time of
|
|
initialization, else.
|
|
b) The value shall be the current number of leap seconds (7.2.3)
|
|
when the node is designed."
|
|
REFERENCE "Section 8.2.4.3 of [1]"
|
|
::= { cPtpClockTimePropertiesDSEntry 5 }
|
|
|
|
cPtpClockTimePropertiesDSLeap59 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Leap59 value in the clock Current
|
|
Dataset."
|
|
REFERENCE "Section 8.2.4.4 of [1]"
|
|
::= { cPtpClockTimePropertiesDSEntry 6 }
|
|
|
|
cPtpClockTimePropertiesDSLeap61 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Leap61 value in the clock Current
|
|
Dataset."
|
|
REFERENCE "Section 8.2.4.5 of [1]"
|
|
::= { cPtpClockTimePropertiesDSEntry 7 }
|
|
|
|
cPtpClockTimePropertiesDSTimeTraceable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Timetraceable value in the clock
|
|
Current Dataset."
|
|
REFERENCE "Section 8.2.4.6 of [1]"
|
|
::= { cPtpClockTimePropertiesDSEntry 8 }
|
|
|
|
cPtpClockTimePropertiesDSFreqTraceable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Frequency Traceable value in the
|
|
clock Current Dataset."
|
|
REFERENCE "Section 8.2.4.7 of [1]"
|
|
::= { cPtpClockTimePropertiesDSEntry 9 }
|
|
|
|
cPtpClockTimePropertiesDSPTPTimescale OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP Timescale value in the clock
|
|
Current Dataset."
|
|
REFERENCE "Section 8.2.4.8 of [1]"
|
|
::= { cPtpClockTimePropertiesDSEntry 10 }
|
|
|
|
cPtpClockTimePropertiesDSSource OBJECT-TYPE
|
|
SYNTAX ClockTimeSourceType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Timesource value in the clock Current
|
|
Dataset."
|
|
REFERENCE "Section 8.2.4.9 of [1]"
|
|
::= { cPtpClockTimePropertiesDSEntry 11 }
|
|
|
|
|
|
|
|
cPtpClockTransDefaultDSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockTransDefaultDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP Transparent clock Default
|
|
Datasets for all domains."
|
|
::= { ciscoPtpMIBClockInfo 6 }
|
|
|
|
cPtpClockTransDefaultDSEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockTransDefaultDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
PTP Transparent clock Default Datasets for a domain."
|
|
REFERENCE "Section 8.3.2 of [1]"
|
|
INDEX {
|
|
cPtpClockTransDefaultDSDomainIndex,
|
|
cPtpClockTransDefaultDSInstanceIndex
|
|
}
|
|
::= { cPtpClockTransDefaultDSTable 1 }
|
|
|
|
CPtpClockTransDefaultDSEntry ::= SEQUENCE {
|
|
cPtpClockTransDefaultDSDomainIndex ClockDomainType,
|
|
cPtpClockTransDefaultDSInstanceIndex ClockInstanceType,
|
|
cPtpClockTransDefaultDSClockIdentity ClockIdentity,
|
|
cPtpClockTransDefaultDSNumOfPorts Counter32,
|
|
cPtpClockTransDefaultDSDelay ClockMechanismType,
|
|
cPtpClockTransDefaultDSPrimaryDomain Integer32
|
|
}
|
|
|
|
cPtpClockTransDefaultDSDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockTransDefaultDSEntry 1 }
|
|
|
|
cPtpClockTransDefaultDSInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockTransDefaultDSEntry 2 }
|
|
|
|
cPtpClockTransDefaultDSClockIdentity OBJECT-TYPE
|
|
SYNTAX ClockIdentity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the value of the clockIdentity attribute
|
|
of the local clock."
|
|
REFERENCE "Section 8.3.2.2.1 of [1]"
|
|
::= { cPtpClockTransDefaultDSEntry 3 }
|
|
|
|
cPtpClockTransDefaultDSNumOfPorts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of PTP ports of the device."
|
|
REFERENCE "Section 8.3.2.2.2 of [1]"
|
|
::= { cPtpClockTransDefaultDSEntry 4 }
|
|
|
|
cPtpClockTransDefaultDSDelay OBJECT-TYPE
|
|
SYNTAX ClockMechanismType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object, if the transparent clock is an end-to-end
|
|
transparent clock, has the value shall be E2E; If the
|
|
transparent clock is a peer-to-peer transparent clock, the
|
|
value
|
|
shall be P2P."
|
|
REFERENCE "Section 8.3.2.3.1 of [1]"
|
|
::= { cPtpClockTransDefaultDSEntry 5 }
|
|
|
|
cPtpClockTransDefaultDSPrimaryDomain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the value of the primary syntonization
|
|
domain. The initialization value shall be 0."
|
|
REFERENCE "Section 8.3.2.3.2 of [1]"
|
|
::= { cPtpClockTransDefaultDSEntry 6 }
|
|
|
|
|
|
|
|
cPtpClockPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the clock ports for a particular
|
|
domain."
|
|
::= { ciscoPtpMIBClockInfo 7 }
|
|
|
|
cPtpClockPortEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
clock port."
|
|
INDEX {
|
|
cPtpClockPortDomainIndex,
|
|
cPtpClockPortClockTypeIndex,
|
|
cPtpClockPortClockInstanceIndex,
|
|
cPtpClockPortTablePortNumberIndex
|
|
}
|
|
::= { cPtpClockPortTable 1 }
|
|
|
|
CPtpClockPortEntry ::= SEQUENCE {
|
|
cPtpClockPortDomainIndex ClockDomainType,
|
|
cPtpClockPortClockTypeIndex ClockType,
|
|
cPtpClockPortClockInstanceIndex ClockInstanceType,
|
|
cPtpClockPortTablePortNumberIndex ClockPortNumber,
|
|
cPtpClockPortName DisplayString,
|
|
cPtpClockPortRole ClockRoleType,
|
|
cPtpClockPortSyncOneStep TruthValue,
|
|
cPtpClockPortCurrentPeerAddressType InetAddressType,
|
|
cPtpClockPortCurrentPeerAddress InetAddress,
|
|
cPtpClockPortNumOfAssociatedPorts Gauge32,
|
|
cPtpClockPortBlockGMC TruthValue,
|
|
cPtpClockRogueMasterDetect TruthValue
|
|
}
|
|
|
|
cPtpClockPortDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockPortEntry 1 }
|
|
|
|
cPtpClockPortClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the
|
|
Textual convention description."
|
|
::= { cPtpClockPortEntry 2 }
|
|
|
|
cPtpClockPortClockInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockPortEntry 3 }
|
|
|
|
cPtpClockPortTablePortNumberIndex OBJECT-TYPE
|
|
SYNTAX ClockPortNumber (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP Portnumber for this port."
|
|
::= { cPtpClockPortEntry 4 }
|
|
|
|
cPtpClockPortName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP clock port name configured on the
|
|
router."
|
|
::= { cPtpClockPortEntry 5 }
|
|
|
|
cPtpClockPortRole OBJECT-TYPE
|
|
SYNTAX ClockRoleType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object describes the current role (slave/master) of the
|
|
port."
|
|
::= { cPtpClockPortEntry 6 }
|
|
|
|
cPtpClockPortSyncOneStep OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies that one-step clock operation between
|
|
the PTP master and slave device is enabled."
|
|
::= { cPtpClockPortEntry 7 }
|
|
|
|
cPtpClockPortCurrentPeerAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the current peer's network address used
|
|
for PTP communication. Based on the scenario and the setup
|
|
involved, the values might look like these -
|
|
Scenario Value
|
|
------------------- ----------------
|
|
Single Master master port
|
|
Multiple Masters selected master port
|
|
Single Slave slave port
|
|
Multiple Slaves <empty>
|
|
|
|
(In relevant setups, information on available
|
|
slaves and available masters will be available through
|
|
cPtpClockPortAssociateTable)"
|
|
::= { cPtpClockPortEntry 8 }
|
|
|
|
cPtpClockPortCurrentPeerAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the current peer's network address used
|
|
for PTP communication. Based on the scenario and the setup
|
|
involved, the values might look like these -
|
|
Scenario Value
|
|
------------------- ----------------
|
|
Single Master master port
|
|
Multiple Masters selected master port
|
|
Single Slave slave port
|
|
Multiple Slaves <empty>
|
|
|
|
(In relevant setups, information on available
|
|
slaves and available masters will be available through
|
|
cPtpClockPortAssociateTable)"
|
|
::= { cPtpClockPortEntry 9 }
|
|
|
|
cPtpClockPortNumOfAssociatedPorts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies -
|
|
For a master port - the number of PTP slave sessions (peers)
|
|
associated with this PTP port.
|
|
For a slave port - the number of masters available to this slave
|
|
port (might or might not be peered)."
|
|
::= { cPtpClockPortEntry 10 }
|
|
|
|
cPtpClockPortBlockGMC OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies that the ptp port is configured with ptp
|
|
gmc-block or not."
|
|
::= { cPtpClockPortEntry 11 }
|
|
|
|
cPtpClockRogueMasterDetect OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies that port receives the PTP packets from
|
|
other network, which the device is not interested to sync with."
|
|
::= { cPtpClockPortEntry 12 }
|
|
|
|
|
|
|
|
cPtpClockPortDSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockPortDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the clock ports dataset for a
|
|
particular domain."
|
|
::= { ciscoPtpMIBClockInfo 8 }
|
|
|
|
cPtpClockPortDSEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockPortDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing port dataset information for
|
|
a single clock port."
|
|
INDEX {
|
|
cPtpClockPortDSDomainIndex,
|
|
cPtpClockPortDSClockTypeIndex,
|
|
cPtpClockPortDSClockInstanceIndex,
|
|
cPtpClockPortDSPortNumberIndex
|
|
}
|
|
::= { cPtpClockPortDSTable 1 }
|
|
|
|
CPtpClockPortDSEntry ::= SEQUENCE {
|
|
cPtpClockPortDSDomainIndex ClockDomainType,
|
|
cPtpClockPortDSClockTypeIndex ClockType,
|
|
cPtpClockPortDSClockInstanceIndex ClockInstanceType,
|
|
cPtpClockPortDSPortNumberIndex ClockPortNumber,
|
|
cPtpClockPortDSName DisplayString,
|
|
cPtpClockPortDSPortIdentity OCTET STRING,
|
|
cPtpClockPortDSAnnouncementInterval Integer32,
|
|
cPtpClockPortDSAnnounceRctTimeout Integer32,
|
|
cPtpClockPortDSSyncInterval Integer32,
|
|
cPtpClockPortDSMinDelayReqInterval Integer32,
|
|
cPtpClockPortDSPeerDelayReqInterval Integer32,
|
|
cPtpClockPortDSDelayMech ClockMechanismType,
|
|
cPtpClockPortDSPeerMeanPathDelay ClockTimeInterval,
|
|
cPtpClockPortDSGrantDuration Unsigned32,
|
|
cPtpClockPortDSPTPVersion Integer32
|
|
}
|
|
|
|
cPtpClockPortDSDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockPortDSEntry 1 }
|
|
|
|
cPtpClockPortDSClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the
|
|
Textual convention description."
|
|
::= { cPtpClockPortDSEntry 2 }
|
|
|
|
cPtpClockPortDSClockInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockPortDSEntry 3 }
|
|
|
|
cPtpClockPortDSPortNumberIndex OBJECT-TYPE
|
|
SYNTAX ClockPortNumber (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP portnumber associated with this
|
|
PTP port."
|
|
::= { cPtpClockPortDSEntry 4 }
|
|
|
|
cPtpClockPortDSName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP clock port name."
|
|
::= { cPtpClockPortDSEntry 5 }
|
|
|
|
cPtpClockPortDSPortIdentity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP clock port Identity."
|
|
::= { cPtpClockPortDSEntry 6 }
|
|
|
|
cPtpClockPortDSAnnouncementInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Announce message transmission
|
|
interval associated with this clock port."
|
|
::= { cPtpClockPortDSEntry 7 }
|
|
|
|
cPtpClockPortDSAnnounceRctTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Announce receipt timeout associated
|
|
with this clock port."
|
|
::= { cPtpClockPortDSEntry 8 }
|
|
|
|
cPtpClockPortDSSyncInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Sync message transmission interval."
|
|
::= { cPtpClockPortDSEntry 9 }
|
|
|
|
cPtpClockPortDSMinDelayReqInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Delay_Req message transmission
|
|
interval."
|
|
::= { cPtpClockPortDSEntry 10 }
|
|
|
|
cPtpClockPortDSPeerDelayReqInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Pdelay_Req message transmission
|
|
interval."
|
|
::= { cPtpClockPortDSEntry 11 }
|
|
|
|
cPtpClockPortDSDelayMech OBJECT-TYPE
|
|
SYNTAX ClockMechanismType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the delay mechanism used. If the clock
|
|
is an end-to-end clock, the value of the is e2e, else if the
|
|
clock is a peer to-peer clock, the value shall be p2p."
|
|
::= { cPtpClockPortDSEntry 12 }
|
|
|
|
cPtpClockPortDSPeerMeanPathDelay OBJECT-TYPE
|
|
SYNTAX ClockTimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the peer meanPathDelay."
|
|
::= { cPtpClockPortDSEntry 13 }
|
|
|
|
cPtpClockPortDSGrantDuration OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the grant duration allocated by the
|
|
master."
|
|
::= { cPtpClockPortDSEntry 14 }
|
|
|
|
cPtpClockPortDSPTPVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP version being used."
|
|
::= { cPtpClockPortDSEntry 15 }
|
|
|
|
|
|
|
|
cPtpClockPortRunningTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockPortRunningEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the clock ports running dataset for
|
|
a particular domain."
|
|
::= { ciscoPtpMIBClockInfo 9 }
|
|
|
|
cPtpClockPortRunningEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockPortRunningEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing runing dataset information
|
|
about a single clock port."
|
|
INDEX {
|
|
cPtpClockPortRunningDomainIndex,
|
|
cPtpClockPortRunningClockTypeIndex,
|
|
cPtpClockPortRunningClockInstanceIndex,
|
|
cPtpClockPortRunningPortNumberIndex
|
|
}
|
|
::= { cPtpClockPortRunningTable 1 }
|
|
|
|
CPtpClockPortRunningEntry ::= SEQUENCE {
|
|
cPtpClockPortRunningDomainIndex ClockDomainType,
|
|
cPtpClockPortRunningClockTypeIndex ClockType,
|
|
cPtpClockPortRunningClockInstanceIndex ClockInstanceType,
|
|
cPtpClockPortRunningPortNumberIndex ClockPortNumber,
|
|
cPtpClockPortRunningName DisplayString,
|
|
cPtpClockPortRunningState ClockPortState,
|
|
cPtpClockPortRunningRole ClockRoleType,
|
|
cPtpClockPortRunningInterfaceIndex InterfaceIndexOrZero,
|
|
cPtpClockPortRunningIPversion Integer32,
|
|
cPtpClockPortRunningEncapsulationType Integer32,
|
|
cPtpClockPortRunningTxMode ClockTxModeType,
|
|
cPtpClockPortRunningRxMode ClockTxModeType,
|
|
cPtpClockPortRunningPacketsReceived Counter64,
|
|
cPtpClockPortRunningPacketsSent Counter64
|
|
}
|
|
|
|
cPtpClockPortRunningDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockPortRunningEntry 1 }
|
|
|
|
cPtpClockPortRunningClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the
|
|
Textual convention description."
|
|
::= { cPtpClockPortRunningEntry 2 }
|
|
|
|
cPtpClockPortRunningClockInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockPortRunningEntry 3 }
|
|
|
|
cPtpClockPortRunningPortNumberIndex OBJECT-TYPE
|
|
SYNTAX ClockPortNumber (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP portnumber associated with this
|
|
clock port."
|
|
::= { cPtpClockPortRunningEntry 4 }
|
|
|
|
cPtpClockPortRunningName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP clock port name."
|
|
::= { cPtpClockPortRunningEntry 5 }
|
|
|
|
cPtpClockPortRunningState OBJECT-TYPE
|
|
SYNTAX ClockPortState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the port state returned by PTP engine.
|
|
|
|
initializing - In this state a port initializes
|
|
its data sets, hardware, and
|
|
communication facilities.
|
|
faulty - The fault state of the protocol.
|
|
disabled - The port shall not place any
|
|
messages on its communication path.
|
|
listening - The port is waiting for the
|
|
announceReceiptTimeout to expire or
|
|
to receive an Announce message from
|
|
a master.
|
|
preMaster - The port shall behave in all respects
|
|
as though it were in the MASTER state
|
|
except that it shall not place any
|
|
messages on its communication path
|
|
except for Pdelay_Req, Pdelay_Resp,
|
|
Pdelay_Resp_Follow_Up, signaling, or
|
|
management messages.
|
|
master - The port is behaving as a master port.
|
|
|
|
passive - The port shall not place any
|
|
messages on its communication path
|
|
except for Pdelay_Req, Pdelay_Resp,
|
|
Pdelay_Resp_Follow_Up, or signaling
|
|
messages, or management messages
|
|
that are a required response to
|
|
another management message
|
|
uncalibrated - The local port is preparing to
|
|
synchronize to the master port.
|
|
slave - The port is synchronizing to the
|
|
selected master port."
|
|
::= { cPtpClockPortRunningEntry 6 }
|
|
|
|
cPtpClockPortRunningRole OBJECT-TYPE
|
|
SYNTAX ClockRoleType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Clock Role."
|
|
::= { cPtpClockPortRunningEntry 7 }
|
|
|
|
cPtpClockPortRunningInterfaceIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the interface on the router being used by
|
|
the PTP Clock for PTP communication."
|
|
::= { cPtpClockPortRunningEntry 8 }
|
|
|
|
cPtpClockPortRunningIPversion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifirst the IP version being used for PTP
|
|
communication (the mapping used)."
|
|
::= { cPtpClockPortRunningEntry 9 }
|
|
|
|
cPtpClockPortRunningEncapsulationType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the type of encapsulation if the
|
|
interface is adding extra layers (eg. VLAN, Pseudowire
|
|
encapsulation...) for the PTP messages."
|
|
::= { cPtpClockPortRunningEntry 10 }
|
|
|
|
cPtpClockPortRunningTxMode OBJECT-TYPE
|
|
SYNTAX ClockTxModeType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock transmission mode as
|
|
|
|
unicast: Using unicast commnuication channel.
|
|
multicast: Using Multicast communication channel.
|
|
multicast-mix: Using multicast-unicast communication channel"
|
|
::= { cPtpClockPortRunningEntry 11 }
|
|
|
|
cPtpClockPortRunningRxMode OBJECT-TYPE
|
|
SYNTAX ClockTxModeType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifie the clock receive mode as
|
|
|
|
unicast: Using unicast commnuication channel.
|
|
multicast: Using Multicast communication channel.
|
|
multicast-mix: Using multicast-unicast communication channel"
|
|
::= { cPtpClockPortRunningEntry 12 }
|
|
|
|
cPtpClockPortRunningPacketsReceived OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the packets received on the clock port
|
|
(cummulative)."
|
|
::= { cPtpClockPortRunningEntry 13 }
|
|
|
|
cPtpClockPortRunningPacketsSent OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the packets sent on the clock port
|
|
(cummulative)."
|
|
::= { cPtpClockPortRunningEntry 14 }
|
|
|
|
|
|
|
|
cPtpClockPortTransDSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockPortTransDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the Transparent clock ports running
|
|
dataset for a particular domain."
|
|
::= { ciscoPtpMIBClockInfo 10 }
|
|
|
|
cPtpClockPortTransDSEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockPortTransDSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing clock port Transparent
|
|
dataset information about a single clock port"
|
|
INDEX {
|
|
cPtpClockPortTransDSDomainIndex,
|
|
cPtpClockPortTransDSInstanceIndex,
|
|
cPtpClockPortTransDSPortNumberIndex
|
|
}
|
|
::= { cPtpClockPortTransDSTable 1 }
|
|
|
|
CPtpClockPortTransDSEntry ::= SEQUENCE {
|
|
cPtpClockPortTransDSDomainIndex ClockDomainType,
|
|
cPtpClockPortTransDSInstanceIndex ClockInstanceType,
|
|
cPtpClockPortTransDSPortNumberIndex ClockPortNumber,
|
|
cPtpClockPortTransDSPortIdentity ClockIdentity,
|
|
cPtpClockPortTransDSlogMinPdelayReqInt Integer32,
|
|
cPtpClockPortTransDSFaultyFlag TruthValue,
|
|
cPtpClockPortTransDSPeerMeanPathDelay ClockTimeInterval
|
|
}
|
|
|
|
cPtpClockPortTransDSDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockPortTransDSEntry 1 }
|
|
|
|
cPtpClockPortTransDSInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockPortTransDSEntry 2 }
|
|
|
|
cPtpClockPortTransDSPortNumberIndex OBJECT-TYPE
|
|
SYNTAX ClockPortNumber (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP port number associated with this
|
|
port."
|
|
REFERENCE "Section 7.5.2 Port Identity of [1]"
|
|
::= { cPtpClockPortTransDSEntry 3 }
|
|
|
|
cPtpClockPortTransDSPortIdentity OBJECT-TYPE
|
|
SYNTAX ClockIdentity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the value of the PortIdentity
|
|
attribute of the local port."
|
|
REFERENCE "Section 8.3.3.2.1 of [1]"
|
|
::= { cPtpClockPortTransDSEntry 4 }
|
|
|
|
cPtpClockPortTransDSlogMinPdelayReqInt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the value of the logarithm to the
|
|
base 2 of the minPdelayReqInterval."
|
|
REFERENCE "Section 8.3.3.3.1 of [1]"
|
|
::= { cPtpClockPortTransDSEntry 5 }
|
|
|
|
cPtpClockPortTransDSFaultyFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the value TRUE if the port is faulty
|
|
and FALSE if the port is operating normally."
|
|
REFERENCE "Section 8.3.3.3.2 of [1]"
|
|
::= { cPtpClockPortTransDSEntry 6 }
|
|
|
|
cPtpClockPortTransDSPeerMeanPathDelay OBJECT-TYPE
|
|
SYNTAX ClockTimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies, (if the delayMechanism used is P2P) the
|
|
value is the estimate of the current one-way propagation delay,
|
|
i.e., <meanPathDelay> on the link attached to this port
|
|
computed
|
|
using the peer delay mechanism. If the value of the
|
|
delayMechanism
|
|
used is E2E, then the value will be zero."
|
|
REFERENCE "Section 8.3.3.3.3 of [1]"
|
|
::= { cPtpClockPortTransDSEntry 7 }
|
|
|
|
|
|
|
|
cPtpClockPortAssociateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockPortAssociateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about a given port's associated ports.
|
|
|
|
For a master port - multiple slave ports which have established
|
|
sessions with the current master port.
|
|
For a slave port - the list of masters available for a given
|
|
slave port.
|
|
|
|
Session information (pkts, errors) to be displayed based on
|
|
availability and scenario."
|
|
::= { ciscoPtpMIBClockInfo 11 }
|
|
|
|
cPtpClockPortAssociateEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockPortAssociateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
associated port for the given clockport."
|
|
INDEX {
|
|
cPtpClockPortCurrentDomainIndex,
|
|
cPtpClockPortCurrentClockTypeIndex,
|
|
cPtpClockPortCurrentClockInstanceIndex,
|
|
cPtpClockPortCurrentPortNumberIndex,
|
|
cPtpClockPortAssociatePortIndex
|
|
}
|
|
::= { cPtpClockPortAssociateTable 1 }
|
|
|
|
CPtpClockPortAssociateEntry ::= SEQUENCE {
|
|
cPtpClockPortCurrentDomainIndex ClockDomainType,
|
|
cPtpClockPortCurrentClockTypeIndex ClockType,
|
|
cPtpClockPortCurrentClockInstanceIndex ClockInstanceType,
|
|
cPtpClockPortCurrentPortNumberIndex ClockPortNumber,
|
|
cPtpClockPortAssociatePortIndex Unsigned32,
|
|
cPtpClockPortAssociateAddressType InetAddressType,
|
|
cPtpClockPortAssociateAddress InetAddress,
|
|
cPtpClockPortAssociatePacketsSent Counter64,
|
|
cPtpClockPortAssociatePacketsReceived Counter64,
|
|
cPtpClockPortAssociateInErrors Counter64,
|
|
cPtpClockPortAssociateOutErrors Counter64
|
|
}
|
|
|
|
cPtpClockPortCurrentDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the given port's domain number."
|
|
::= { cPtpClockPortAssociateEntry 1 }
|
|
|
|
cPtpClockPortCurrentClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the given port's clock type."
|
|
::= { cPtpClockPortAssociateEntry 2 }
|
|
|
|
cPtpClockPortCurrentClockInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockPortAssociateEntry 3 }
|
|
|
|
cPtpClockPortCurrentPortNumberIndex OBJECT-TYPE
|
|
SYNTAX ClockPortNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP Port Number for the given port."
|
|
::= { cPtpClockPortAssociateEntry 4 }
|
|
|
|
cPtpClockPortAssociatePortIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the associated port's serial number in
|
|
the current port's context."
|
|
::= { cPtpClockPortAssociateEntry 5 }
|
|
|
|
cPtpClockPortAssociateAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the peer port's network address type used
|
|
for PTP communication."
|
|
::= { cPtpClockPortAssociateEntry 6 }
|
|
|
|
cPtpClockPortAssociateAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the peer port's network address used for
|
|
PTP communication."
|
|
::= { cPtpClockPortAssociateEntry 7 }
|
|
|
|
cPtpClockPortAssociatePacketsSent OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets sent to this peer port from the current
|
|
port."
|
|
::= { cPtpClockPortAssociateEntry 8 }
|
|
|
|
cPtpClockPortAssociatePacketsReceived OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets received from this peer port by the
|
|
current port."
|
|
::= { cPtpClockPortAssociateEntry 9 }
|
|
|
|
cPtpClockPortAssociateInErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the input errors associated with the
|
|
peer port."
|
|
::= { cPtpClockPortAssociateEntry 10 }
|
|
|
|
cPtpClockPortAssociateOutErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the output errors associated with the
|
|
peer port."
|
|
::= { cPtpClockPortAssociateEntry 11 }
|
|
|
|
|
|
|
|
cPtpClockSystemTimePropertiesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CPtpClockSystemTimePropertiesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP clock System
|
|
Timeproperties."
|
|
::= { ciscoPtpMIBClockInfo 12 }
|
|
|
|
cPtpClockSystemTimePropertiesEntry OBJECT-TYPE
|
|
SYNTAX CPtpClockSystemTimePropertiesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
PTP clock timeproperties for a domain."
|
|
INDEX {
|
|
cPtpClockSystemTimePropertiesDomainIndex,
|
|
cPtpClockSystemTimePropertiesInstanceIndex,
|
|
cPtpClockSystemTimePropertiesClockTypeIndex
|
|
}
|
|
::= { cPtpClockSystemTimePropertiesTable 1 }
|
|
|
|
CPtpClockSystemTimePropertiesEntry ::= SEQUENCE {
|
|
cPtpClockSystemTimePropertiesDomainIndex ClockDomainType,
|
|
cPtpClockSystemTimePropertiesClockTypeIndex ClockType,
|
|
cPtpClockSystemTimePropertiesInstanceIndex ClockInstanceType,
|
|
cPtpClockSystemTimePropertiesClockSyntonized TruthValue,
|
|
cPtpClockSystemTimePropertiesDomainSyntonized TruthValue,
|
|
cPtpClockSystemTimePropertiesFrequencyOffset Integer32
|
|
}
|
|
|
|
cPtpClockSystemTimePropertiesDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices."
|
|
::= { cPtpClockSystemTimePropertiesEntry 1 }
|
|
|
|
cPtpClockSystemTimePropertiesClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the textual
|
|
convention description."
|
|
::= { cPtpClockSystemTimePropertiesEntry 2 }
|
|
|
|
cPtpClockSystemTimePropertiesInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the clock for this clock
|
|
type in the given domain."
|
|
::= { cPtpClockSystemTimePropertiesEntry 3 }
|
|
|
|
cPtpClockSystemTimePropertiesClockSyntonized OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies if slave device's ptp clock is in sync
|
|
with GM clock or not."
|
|
::= { cPtpClockSystemTimePropertiesEntry 4 }
|
|
|
|
cPtpClockSystemTimePropertiesDomainSyntonized OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies if slave device's ptp clock domain value
|
|
is in sync with GM clock or not."
|
|
::= { cPtpClockSystemTimePropertiesEntry 5 }
|
|
|
|
cPtpClockSystemTimePropertiesFrequencyOffset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the timeproperties value of frequency
|
|
offset."
|
|
::= { cPtpClockSystemTimePropertiesEntry 6 }
|
|
|
|
|
|
|
|
END
|
|
|
|
|