-- CISCO-FLOW-METADATA-MIB.my
|
|
--
|
|
-- Vignesh C R
|
|
-- Copyright (c) 2005-2006-2012 by cisco Systems Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
|
|
CISCO-FLOW-METADATA-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
InetAddressType,
|
|
InetAddress,
|
|
InetPortNumber
|
|
FROM INET-ADDRESS-MIB
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
ciscoMgmt
|
|
FROM CISCO-SMI;
|
|
|
|
|
|
ciscoFlowMetadataMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201212200000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
"Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: cs-medianet-metadata@cisco.com"
|
|
DESCRIPTION
|
|
"The MIB module for managing Cisco medianet flow metadata.
|
|
Metadata, in the simplest form, is data that qualifies
|
|
other data. Flow metadata is data that describes a flow
|
|
in the network. Metadata plays an important role in providing
|
|
a framework, that makes data from one component available to
|
|
another component on the same network element as well as
|
|
across other network elements.
|
|
|
|
MIB Table Overview:
|
|
===================
|
|
This MIB consists of two tables:
|
|
|
|
1) cfmMetadataFlowTable
|
|
2) cfmMetadataFlowAttrTable
|
|
|
|
cfmMetadataFlowTable provides the details about the six tuple
|
|
which can uniquely identify a network traffic flow.
|
|
|
|
cfmMetadataFlowAttrTable will specify flow attributes carried
|
|
in the metadata flow. Flow attribute values are
|
|
represented in 'Type-Value' format.
|
|
|
|
cfmMetadataFlowAttrType - Represent the type of flow attribute.
|
|
cfmMetadataFlowAttrValue - Represent corresponding flow
|
|
attribute value.
|
|
|
|
cfmMetadataFlowTable and cfmMetadataFlowAttrTable are linked
|
|
together using flow ID which will map respective metadata flow
|
|
attributes with the corresponding flow key."
|
|
REVISION "201212170000Z"
|
|
DESCRIPTION
|
|
"Deprecated
|
|
|
|
CfmMetadataFlowAttrType
|
|
cfmMetadataFlowAttributeTable
|
|
|
|
as coupled to transport protocol.
|
|
Added
|
|
|
|
cfmMetadataFlowAllAttrTable
|
|
|
|
decoupling it from transport protocol."
|
|
REVISION "201103200000Z"
|
|
DESCRIPTION
|
|
"Latest version of this MIB module."
|
|
::= { ciscoMgmt 789 }
|
|
|
|
|
|
|
|
-- Textual Conventions definition will be defined before this line
|
|
|
|
CfmMetadataFlowAttributeType ::= TEXTUAL-CONVENTION
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object specifies the attributes types
|
|
that is applicable to a given flow.
|
|
|
|
The following are the entire possible metadata attribute
|
|
types and a brief explanation for the same.
|
|
|
|
other(0) - Other attribute types than listed below.
|
|
appDescription(94) - Application description of the
|
|
the flow. It is represented as a string of
|
|
length 55 characters.
|
|
appTag(95) - Application tag value of the flow.
|
|
It is represented as unsigned32.
|
|
appName(96) - Application name of the flow. It is
|
|
represented as a string of length 24 characters.
|
|
appVersion(97) - Application version of the flow. It is
|
|
represented as a string of length 40 characters.
|
|
appVendor(98) - Application vendor of the flow. It is
|
|
represented as a string of length 40 characters.
|
|
vmFlowTimeout(100) - Flow time out value of the flow.
|
|
It is represented as unsigned32.
|
|
vmRTPClockFrequency(101) - Clock frequency of the flow.
|
|
It is represented as unsigned32.
|
|
pakrate(103) - Packet rate of the flow. It is
|
|
represented as unsigned64.
|
|
l3Bitrate(104) - L3 bit rate of the flow. It is
|
|
represented as unsigned32.
|
|
mediaBitrate(105) - Media bit rate of the flow. It is
|
|
represented as unsigned32.
|
|
mediaVideoPaksize(106) - Media video bit rate of the flow.
|
|
It is represented as unsigned32.
|
|
globalSessionID(107) - Global session ID of the flow.It is
|
|
represented as a string of length 80 characters.
|
|
multipartySessionID(108) - Multi party session ID of the
|
|
flow. It is represented as a string of length 80
|
|
characters.
|
|
rtpMediaFlow(109) - RTP media flow attribute of the flow.
|
|
It is represented as uint8.
|
|
mediaEncryptionStatus(110) - Media encryption status of the
|
|
flow. It is represented as uint8.
|
|
syntheticTraffic(111) - Synthetic traffic represented
|
|
as uint8.
|
|
meteringPriority(112) - Metering Priority of the flow.
|
|
It is represented as uint8.
|
|
endpointModel(113) - Endpoint device model signaling the
|
|
flow. It is represented as string of 40 characters
|
|
length.
|
|
endpointVendor(114) - Endpoint device vendor signaling
|
|
the flow. It is represented as string of 40
|
|
characters length.
|
|
endpointVersion(115) - Endpoint device version signaling
|
|
the flow. It is represented as string of 40
|
|
characters length.
|
|
ssrc(116) - Synchronization source of the flow. It is
|
|
represented as uint32.
|
|
endpointIPAddressType(117) - IP address type of the
|
|
endpoint device signaling the flow. It is
|
|
represented as uint8.
|
|
endpointIPAddressLength(118) - IP address length of the
|
|
endpoint device signaling the flow. It is
|
|
represented as uint8.
|
|
endpointIPAddressValue(119) - IP address of the endpoint
|
|
device signaling the flow. It is represented as a
|
|
string of 16 characters length.
|
|
sipProxyServerType(120) - SIP proxy server IP address
|
|
type of the flow. It is represented as uint8.
|
|
sipProxyServerLength(121) - SIP proxy server IP address
|
|
length of the flow. It is represented as uint8.
|
|
sipProxyServerValue(122) - SIP proxy server IP address
|
|
of the flow. It is represented as a string of 16
|
|
characters length.
|
|
bandwidth(123) - Bandwidth of the flow. It is represented
|
|
as uint32.
|
|
deviceName(124) - Endpoint device name signaling the flow.
|
|
It is represented as a string of 100 characters
|
|
length.
|
|
deviceClass(125) - Endpoint device class signaling the
|
|
flow. It is represented as a string of 100
|
|
characters length.
|
|
sipUserName(126) - SIP flow user name. It is represented as
|
|
a string of 16 characters length.
|
|
sipEmail(127) - SIP flow email ID. It is represented as a
|
|
string of 24 characters length.
|
|
audioCodec(128) - Audio codec of the flow. It is
|
|
represented as uint8.
|
|
bandwidthConsumed(129) - Bandwidth consumed of the flow.
|
|
It is represented as uint32.
|
|
payloadType(130) - Payload type of the flow. It is
|
|
represented as uint8.
|
|
mimeType(131) - MIME type of the flow. It is represented
|
|
as a string of 16 characters length.
|
|
extrapolatedBandwidth(132) - Extrapolated bandwidth of the
|
|
flow. It is represented as uint32.
|
|
cname(134) - cname of the flow. It is represented as a
|
|
string of 24 characters in length.
|
|
videoCodec(135) - Video codec of the flow. It is
|
|
represented as uint8.
|
|
sdpSessionID(136) - SDP session ID of the flow. It is
|
|
represented as a string of 80 characters length.
|
|
domainName(137) - Domain name of the flow. It is
|
|
represented as a string of 24 characters length.
|
|
endpointSwVersion(138) - Software version of the endpoint
|
|
device signaling the flow. It is represented as a
|
|
string of 24 characters length.
|
|
tosDscp(139) - Tos/Dscp value of the flow. It is
|
|
represented as uint8.
|
|
|
|
This textual-convention and objects of this type have been
|
|
deprecated as no longer needed.
|
|
CfmMetadataFlowAttributeType object is superseded by cfmMetadataFlowAllAttrValue."
|
|
SYNTAX INTEGER {
|
|
other(0),
|
|
appDescription(94),
|
|
appTag(95),
|
|
appName(96),
|
|
appVersion(97),
|
|
appVendor(98),
|
|
vmFlowTimeout(100),
|
|
vmRTPClockFrequency(101),
|
|
pakRate(103),
|
|
l3Bitrate(104),
|
|
mediaBitrate(105),
|
|
mediaVideoPaksize(106),
|
|
globalSessionID(107),
|
|
multipartySessionID(108),
|
|
rtpMediaFlow(109),
|
|
mediaEncryptionStatus(110),
|
|
syntheticTraffic(111),
|
|
meteringPriority(112),
|
|
endpointModel(113),
|
|
endpointVendor(114),
|
|
endpointVersion(115),
|
|
ssrc(116),
|
|
endpointIPAddressType(117),
|
|
endpointIPAddressLength(118),
|
|
endpointIPAddressValue(119),
|
|
sipProxyServerType(120),
|
|
sipProxyServerLength(121),
|
|
sipProxyServerValue(122),
|
|
bandwidth(123),
|
|
deviceName(124),
|
|
deviceClass(125),
|
|
sipUserName(126),
|
|
sipEmail(127),
|
|
audioCodec(128),
|
|
bandwidthConsumed(129),
|
|
payloadType(130),
|
|
mimeType(131),
|
|
extrapolatedBandwidth(132),
|
|
cname(134),
|
|
videoCodec(135),
|
|
sdpSessionID(136),
|
|
domainName(137),
|
|
endpointSwVersion(138),
|
|
tosDscp(139)
|
|
}
|
|
|
|
CfmMetadataFlowAttrVal ::= TEXTUAL-CONVENTION
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This textual convention denotes a value to be used with
|
|
'cfmMetadataFlowAttributeType'. A ' CfmMetadataFlowAttrVal '
|
|
is always interpreted within the context of
|
|
cfmMetadataFlowAttrEntry. Every usage of the
|
|
' CfmMetadataFlowAttrVal' textual convention is
|
|
required to specify the ' CfmMetadataFlowAttributeType '
|
|
object.
|
|
CfmMetadataFlowAttrVal object is deprecated as no longer
|
|
needed."
|
|
SYNTAX OCTET STRING (SIZE (1..255))
|
|
cFlowMetadataMIBNotifs OBJECT IDENTIFIER
|
|
::= { ciscoFlowMetadataMIB 0 }
|
|
|
|
cFlowMetadataMIBObjects OBJECT IDENTIFIER
|
|
::= { ciscoFlowMetadataMIB 1 }
|
|
|
|
cFlowMetadataMIBConform OBJECT IDENTIFIER
|
|
::= { ciscoFlowMetadataMIB 2 }
|
|
|
|
|
|
cfmMetadataFlowTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CfmMetadataFlowEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of 6-tuple and flow id that is used to
|
|
identify the metadata flows."
|
|
::= { cFlowMetadataMIBObjects 1 }
|
|
|
|
cfmMetadataFlowEntry OBJECT-TYPE
|
|
SYNTAX CfmMetadataFlowEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing the flow id and the 6-tuple
|
|
which is used as a key to uniquely identify a
|
|
metadata flow ."
|
|
INDEX { cfmMetadataFlowId }
|
|
::= { cfmMetadataFlowTable 1 }
|
|
|
|
CfmMetadataFlowEntry ::= SEQUENCE {
|
|
cfmMetadataFlowId Unsigned32,
|
|
cfmMetadataFlowProtocolType INTEGER,
|
|
cfmMetadataFlowDestAddrType InetAddressType,
|
|
cfmMetadataFlowDestAddr InetAddress,
|
|
cfmMetadataFlowDestPort InetPortNumber,
|
|
cfmMetadataFlowSrcAddrType InetAddressType,
|
|
cfmMetadataFlowSrcAddr InetAddress,
|
|
cfmMetadataFlowSrcPort InetPortNumber,
|
|
cfmMetadataFlowSSRC Unsigned32
|
|
}
|
|
|
|
cfmMetadataFlowId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ID that uniquely identifies this metadata flow.
|
|
It is dynamically generated once the flow key
|
|
information is available and assigned to the flow."
|
|
::= { cfmMetadataFlowEntry 1 }
|
|
|
|
cfmMetadataFlowProtocolType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(1),
|
|
udp(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The protocol type of this metadata flow."
|
|
::= { cfmMetadataFlowEntry 2 }
|
|
|
|
cfmMetadataFlowDestAddrType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of destination Internet address of
|
|
this metadata flow."
|
|
::= { cfmMetadataFlowEntry 3 }
|
|
|
|
cfmMetadataFlowDestAddr OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination Internet address of this metadata flow.
|
|
The type of this address is determined by the value of
|
|
cfmMetadataFlowDestAddrType."
|
|
::= { cfmMetadataFlowEntry 4 }
|
|
|
|
cfmMetadataFlowDestPort OBJECT-TYPE
|
|
SYNTAX InetPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination port of this metadata flow."
|
|
::= { cfmMetadataFlowEntry 5 }
|
|
|
|
cfmMetadataFlowSrcAddrType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of source Internet address of this metadata flow."
|
|
::= { cfmMetadataFlowEntry 6 }
|
|
|
|
cfmMetadataFlowSrcAddr OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source Internet address of this metadata flow.
|
|
The type of this address is determined by the value of
|
|
cfmMetadataFlowSrcAddrType."
|
|
::= { cfmMetadataFlowEntry 7 }
|
|
|
|
cfmMetadataFlowSrcPort OBJECT-TYPE
|
|
SYNTAX InetPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port of this metadata flow."
|
|
::= { cfmMetadataFlowEntry 8 }
|
|
|
|
cfmMetadataFlowSSRC OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..4294967295)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronization Source Identifier (SSRC) of this
|
|
metadata flow."
|
|
::= { cfmMetadataFlowEntry 9 }
|
|
|
|
|
|
|
|
cfmMetadataFlowAttrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CfmMetadataFlowAttrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A list of metadata flows and their additional attribute
|
|
parameters.
|
|
cfmMetadataFlowAttrTable object is superseded by cfmMetadataFlowAttribTable."
|
|
::= { cFlowMetadataMIBObjects 2 }
|
|
|
|
cfmMetadataFlowAttrEntry OBJECT-TYPE
|
|
SYNTAX CfmMetadataFlowAttrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An entry containing additional attribute parameter
|
|
for a particular metadata flow.
|
|
cfmMetadataFlowAttrEntry object is superseded by cfmMetadataFlowAttribEntry."
|
|
INDEX {
|
|
cfmMetadataFlowId,
|
|
cfmMetadataFlowAttrType
|
|
}
|
|
::= { cfmMetadataFlowAttrTable 1 }
|
|
|
|
CfmMetadataFlowAttrEntry ::= SEQUENCE {
|
|
cfmMetadataFlowAttrType CfmMetadataFlowAttributeType,
|
|
cfmMetadataFlowAttrValue CfmMetadataFlowAttrVal
|
|
}
|
|
|
|
cfmMetadataFlowAttrType OBJECT-TYPE
|
|
SYNTAX CfmMetadataFlowAttributeType
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The attribute type applicable to a given metadata flow.
|
|
|
|
The attribute types are explained in
|
|
CfmMetadataFlowAttrType.
|
|
cfmMetadataFlowAttrType object is superseded by
|
|
cfmMetadataIpFixIeId."
|
|
::= { cfmMetadataFlowAttrEntry 1 }
|
|
|
|
cfmMetadataFlowAttrValue OBJECT-TYPE
|
|
SYNTAX CfmMetadataFlowAttrVal
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The attribute value associated with the attribute type
|
|
of a given metadata flow.
|
|
cfmMetadataFlowAttrValue object is superseded by cfmMetadataFlowAttribValue."
|
|
::= { cfmMetadataFlowAttrEntry 2 }
|
|
|
|
|
|
|
|
cfmMetadataFlowAllAttrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CfmMetadataFlowAllAttrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of metadata flows and their additional attribute
|
|
parameters."
|
|
::= { cFlowMetadataMIBObjects 3 }
|
|
|
|
cfmMetadataFlowAllAttrEntry OBJECT-TYPE
|
|
SYNTAX CfmMetadataFlowAllAttrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing additional attribute parameter
|
|
for a particular metadata flow."
|
|
INDEX {
|
|
cfmMetadataFlowId,
|
|
cfmMetadataIpFixIeId,
|
|
cfmMetadataFlowAllAttrInstanceId
|
|
}
|
|
::= { cfmMetadataFlowAllAttrTable 1 }
|
|
|
|
CfmMetadataFlowAllAttrEntry ::= SEQUENCE {
|
|
cfmMetadataIpFixIeId Unsigned32,
|
|
cfmMetadataFlowAllAttrInstanceId Unsigned32,
|
|
cfmMetadataFlowAllAttrValue OCTET STRING,
|
|
cfmMetadataFlowAllAttrPen Unsigned32
|
|
}
|
|
|
|
cfmMetadataIpFixIeId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The attribute IPFix IE-ID associated with the attribute of a
|
|
given metadata flow.
|
|
|
|
Logically, IE-ID is only 15 bits, but in existing transports,
|
|
such as the actual IPFIX transport protocol, and Cisco metadata
|
|
signaling in RSVP, the IE-ID is encoded as a uint16. If the
|
|
high-order bit is 0, then it indicates that VendorID is 0 (IANA
|
|
= IETF standardized attributes)."
|
|
::= { cfmMetadataFlowAllAttrEntry 1 }
|
|
|
|
cfmMetadataFlowAllAttrInstanceId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The attribute arbitrary instance, assigned locally by the
|
|
implementation, associated with the attribute IPFix
|
|
IE-ID of a given metadata flow."
|
|
::= { cfmMetadataFlowAllAttrEntry 2 }
|
|
|
|
cfmMetadataFlowAllAttrValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The attribute value associated with the attribute IPFix IE-ID
|
|
of a given metadata flow."
|
|
::= { cfmMetadataFlowAllAttrEntry 3 }
|
|
|
|
cfmMetadataFlowAllAttrPen OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The attribute IANA Private Enterprise Number associated with
|
|
vendor for the attribute IPFix IE-ID of a given metadata flow."
|
|
REFERENCE
|
|
"http://www.iana.org/assignments/enterprise-numbers"
|
|
::= { cfmMetadataFlowAllAttrEntry 4 }
|
|
|
|
|
|
cfmMetadataMIBCompliances OBJECT IDENTIFIER
|
|
::= { cFlowMetadataMIBConform 1 }
|
|
|
|
cfmMetadataMIBGroups OBJECT IDENTIFIER
|
|
::= { cFlowMetadataMIBConform 2 }
|
|
|
|
|
|
cfmMetadataMIBCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for the CISCO-FLOW-METADATA-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { cfmMetadateFlowInfoGroup }
|
|
::= { cfmMetadataMIBCompliances 1 }
|
|
|
|
cfmMetadataMIBComplianceV2 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the CISCO-FLOW-METADATA-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { cfmMetadateFlowInfoGroupV2 }
|
|
::= { cfmMetadataMIBCompliances 2 }
|
|
|
|
-- Units of Conformance
|
|
|
|
cfmMetadateFlowInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cfmMetadataFlowProtocolType,
|
|
cfmMetadataFlowDestAddrType,
|
|
cfmMetadataFlowDestAddr,
|
|
cfmMetadataFlowDestPort,
|
|
cfmMetadataFlowSrcAddrType,
|
|
cfmMetadataFlowSrcAddr,
|
|
cfmMetadataFlowSrcPort,
|
|
cfmMetadataFlowSSRC,
|
|
cfmMetadataFlowAttrType,
|
|
cfmMetadataFlowAttrValue
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects which provide metadata flow
|
|
information.
|
|
cfmMetadateFlowInfoGroup object is superseded by cfmMetadateFlowInfoGroupV2."
|
|
::= { cfmMetadataMIBGroups 1 }
|
|
|
|
cfmMetadateFlowInfoGroupV2 OBJECT-GROUP
|
|
OBJECTS {
|
|
cfmMetadataFlowProtocolType,
|
|
cfmMetadataFlowDestAddrType,
|
|
cfmMetadataFlowDestAddr,
|
|
cfmMetadataFlowDestPort,
|
|
cfmMetadataFlowSrcAddrType,
|
|
cfmMetadataFlowSrcAddr,
|
|
cfmMetadataFlowSrcPort,
|
|
cfmMetadataFlowSSRC,
|
|
cfmMetadataFlowAllAttrValue,
|
|
cfmMetadataFlowAllAttrPen
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects which provide metadata flow
|
|
information."
|
|
::= { cfmMetadataMIBGroups 2 }
|
|
|
|
END
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|