Observium_CE/mibs/cisco/CISCO-FIREPOWER-VNIC-MIB

9907 lines
344 KiB
Plaintext

-- *********************************************************************
-- CISCO-FIREPOWER-VNIC-MIB.my
--
-- MIB representation of the Cisco Firepower
-- VNIC management information model package
--
-- Created March 2020 by Charles Bullis
--
-- Copyright (c) 2005-2020 Cisco Systems, Inc. All rights reserved.
--
-- *********************************************************************
CISCO-FIREPOWER-VNIC-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Counter32,
Gauge32,
TimeTicks,
Counter64,
Unsigned32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
RowPointer,
DateAndTime,
DisplayString,
MacAddress,
TimeInterval,
TimeStamp,
TruthValue
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
InetAddressIPv4,
InetAddressIPv6
FROM INET-ADDRESS-MIB
ciscoMgmt
FROM CISCO-SMI
CiscoNetworkAddress,
Unsigned64,
CiscoInetAddressMask,
CiscoAlarmSeverity,
TimeIntervalSec
FROM CISCO-TC
ciscoFirepowerMIBObjects,
CfprManagedObjectId,
CfprManagedObjectDn
FROM CISCO-FIREPOWER-MIB
CfprConditionRemoteInvRslt,
CfprDpsecForgedTransmit,
CfprFabricHostPortId,
CfprFabricSSAPortType,
CfprFabricVlanSharingType,
CfprFsmCompletion,
CfprFsmFlags,
CfprFsmFsmStageStatus,
CfprLsConfigState,
CfprNetworkSwitchId,
CfprNwctrlAdminState,
CfprNwctrlLinkFailAction,
CfprNwctrlRegistrationMode,
CfprPolicyPolicyOwner,
CfprVmMgmtPlane,
CfprVnicAEtherIfType,
CfprVnicAFcIfType,
CfprVnicAIpcIfType,
CfprVnicAScsiIfType,
CfprVnicAppRole,
CfprVnicConfigIssues,
CfprVnicConnectionOwner,
CfprVnicConnectionType,
CfprVnicDefBehType,
CfprVnicDefaultAction,
CfprVnicDynamicConReqProtection,
CfprVnicEtherBaseSwitchId,
CfprVnicEtherType,
CfprVnicExternalMgmtIPMode,
CfprVnicFcBasePersBind,
CfprVnicFcBaseType,
CfprVnicFcNodeOwner,
CfprVnicHostNwIOPerfPref,
CfprVnicIPv4DnsPref,
CfprVnicIScsiIfDefType,
CfprVnicIScsiNodeOwner,
CfprVnicIfOperState,
CfprVnicInstantiation,
CfprVnicIpcType,
CfprVnicL2IfSwitchId,
CfprVnicLanConnTemplSwitchId,
CfprVnicLunId,
CfprVnicPortProfileType,
CfprVnicProfileConfigQualifier,
CfprVnicProfileSetFsmCurrentFsm,
CfprVnicProfileSetFsmStageName,
CfprVnicProfileSetFsmTaskItem,
CfprVnicSanConnTemplTarget,
CfprVnicScsiType,
CfprVnicTemplateTarget,
CfprVnicTemplateType,
CfprVnicVhbaBehPolicyType,
CfprVnicVirtualizationPreferenceType,
CfprVnicVnicBehPolicyType,
CfprVnicVnicBootDev,
CfprVnicVnicOperHostPort
FROM CISCO-FIREPOWER-TC-MIB;
cfprVnicObjects MODULE-IDENTITY
LAST-UPDATED "202003100000Z"
ORGANIZATION "Cisco Systems Inc."
CONTACT-INFO
"Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: firepower-mibs@cisco.com"
DESCRIPTION
"MIB representation of the Cisco Firepower
VNIC management information model package"
::= { ciscoFirepowerMIBObjects 83 }
cfprVnicBootIpPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicBootIpPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootIpPolicy managed object table"
::= { cfprVnicObjects 1 }
cfprVnicBootIpPolicyEntry OBJECT-TYPE
SYNTAX CfprVnicBootIpPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicBootIpPolicyTable table."
INDEX { cfprVnicBootIpPolicyInstanceId }
::= { cfprVnicBootIpPolicyTable 1 }
CfprVnicBootIpPolicyEntry ::= SEQUENCE {
cfprVnicBootIpPolicyInstanceId CfprManagedObjectId,
cfprVnicBootIpPolicyDn CfprManagedObjectDn,
cfprVnicBootIpPolicyRn SnmpAdminString,
cfprVnicBootIpPolicyDescr SnmpAdminString,
cfprVnicBootIpPolicyIntId SnmpAdminString,
cfprVnicBootIpPolicyName SnmpAdminString,
cfprVnicBootIpPolicyPolicyLevel Gauge32,
cfprVnicBootIpPolicyPolicyOwner CfprPolicyPolicyOwner,
cfprVnicBootIpPolicyPoolName SnmpAdminString
}
cfprVnicBootIpPolicyInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicBootIpPolicyEntry 1 }
cfprVnicBootIpPolicyDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootIpPolicy:dn managed object property"
::= { cfprVnicBootIpPolicyEntry 2 }
cfprVnicBootIpPolicyRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootIpPolicy:rn managed object property"
::= { cfprVnicBootIpPolicyEntry 3 }
cfprVnicBootIpPolicyDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootIpPolicy:descr managed object property"
::= { cfprVnicBootIpPolicyEntry 4 }
cfprVnicBootIpPolicyIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootIpPolicy:intId managed object property"
::= { cfprVnicBootIpPolicyEntry 5 }
cfprVnicBootIpPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootIpPolicy:name managed object property"
::= { cfprVnicBootIpPolicyEntry 6 }
cfprVnicBootIpPolicyPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootIpPolicy:policyLevel
managed object property"
::= { cfprVnicBootIpPolicyEntry 7 }
cfprVnicBootIpPolicyPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootIpPolicy:policyOwner
managed object property"
::= { cfprVnicBootIpPolicyEntry 8 }
cfprVnicBootIpPolicyPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootIpPolicy:poolName managed
object property"
::= { cfprVnicBootIpPolicyEntry 9 }
cfprVnicBootTargetTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicBootTargetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootTarget managed object table"
::= { cfprVnicObjects 2 }
cfprVnicBootTargetEntry OBJECT-TYPE
SYNTAX CfprVnicBootTargetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicBootTargetTable table."
INDEX { cfprVnicBootTargetInstanceId }
::= { cfprVnicBootTargetTable 1 }
CfprVnicBootTargetEntry ::= SEQUENCE {
cfprVnicBootTargetInstanceId CfprManagedObjectId,
cfprVnicBootTargetDn CfprManagedObjectDn,
cfprVnicBootTargetRn SnmpAdminString,
cfprVnicBootTargetLun SnmpAdminString,
cfprVnicBootTargetWwn Unsigned64
}
cfprVnicBootTargetInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicBootTargetEntry 1 }
cfprVnicBootTargetDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootTarget:dn managed object property"
::= { cfprVnicBootTargetEntry 2 }
cfprVnicBootTargetRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootTarget:rn managed object property"
::= { cfprVnicBootTargetEntry 3 }
cfprVnicBootTargetLun OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootTarget:lun managed object property"
::= { cfprVnicBootTargetEntry 4 }
cfprVnicBootTargetWwn OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:BootTarget:wwn managed object property"
::= { cfprVnicBootTargetEntry 5 }
cfprVnicConnDefTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicConnDefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ConnDef managed object table"
::= { cfprVnicObjects 3 }
cfprVnicConnDefEntry OBJECT-TYPE
SYNTAX CfprVnicConnDefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicConnDefTable table."
INDEX { cfprVnicConnDefInstanceId }
::= { cfprVnicConnDefTable 1 }
CfprVnicConnDefEntry ::= SEQUENCE {
cfprVnicConnDefInstanceId CfprManagedObjectId,
cfprVnicConnDefDn CfprManagedObjectDn,
cfprVnicConnDefRn SnmpAdminString,
cfprVnicConnDefFltAggr Unsigned64,
cfprVnicConnDefLanConnPolicyName SnmpAdminString,
cfprVnicConnDefOperLanConnPolicyName SnmpAdminString,
cfprVnicConnDefOperSanConnPolicyName SnmpAdminString,
cfprVnicConnDefSanConnPolicyName SnmpAdminString
}
cfprVnicConnDefInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicConnDefEntry 1 }
cfprVnicConnDefDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ConnDef:dn managed object property"
::= { cfprVnicConnDefEntry 2 }
cfprVnicConnDefRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ConnDef:rn managed object property"
::= { cfprVnicConnDefEntry 3 }
cfprVnicConnDefFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ConnDef:fltAggr managed object property"
::= { cfprVnicConnDefEntry 4 }
cfprVnicConnDefLanConnPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ConnDef:lanConnPolicyName
managed object property"
::= { cfprVnicConnDefEntry 5 }
cfprVnicConnDefOperLanConnPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ConnDef:operLanConnPolicyName
managed object property"
::= { cfprVnicConnDefEntry 6 }
cfprVnicConnDefOperSanConnPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ConnDef:operSanConnPolicyName
managed object property"
::= { cfprVnicConnDefEntry 7 }
cfprVnicConnDefSanConnPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ConnDef:sanConnPolicyName
managed object property"
::= { cfprVnicConnDefEntry 8 }
cfprVnicDefBehTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicDefBehEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DefBeh managed object table"
::= { cfprVnicObjects 4 }
cfprVnicDefBehEntry OBJECT-TYPE
SYNTAX CfprVnicDefBehEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicDefBehTable table."
INDEX { cfprVnicDefBehInstanceId }
::= { cfprVnicDefBehTable 1 }
CfprVnicDefBehEntry ::= SEQUENCE {
cfprVnicDefBehInstanceId CfprManagedObjectId,
cfprVnicDefBehDn CfprManagedObjectDn,
cfprVnicDefBehRn SnmpAdminString,
cfprVnicDefBehAction CfprVnicDefaultAction,
cfprVnicDefBehDescr SnmpAdminString,
cfprVnicDefBehIntId SnmpAdminString,
cfprVnicDefBehName SnmpAdminString,
cfprVnicDefBehNwTemplName SnmpAdminString,
cfprVnicDefBehPolicyLevel Gauge32,
cfprVnicDefBehPolicyOwner CfprPolicyPolicyOwner,
cfprVnicDefBehType CfprVnicDefBehType
}
cfprVnicDefBehInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicDefBehEntry 1 }
cfprVnicDefBehDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DefBeh:dn managed object property"
::= { cfprVnicDefBehEntry 2 }
cfprVnicDefBehRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DefBeh:rn managed object property"
::= { cfprVnicDefBehEntry 3 }
cfprVnicDefBehAction OBJECT-TYPE
SYNTAX CfprVnicDefaultAction
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DefBeh:action managed object property"
::= { cfprVnicDefBehEntry 4 }
cfprVnicDefBehDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DefBeh:descr managed object property"
::= { cfprVnicDefBehEntry 5 }
cfprVnicDefBehIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DefBeh:intId managed object property"
::= { cfprVnicDefBehEntry 6 }
cfprVnicDefBehName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DefBeh:name managed object property"
::= { cfprVnicDefBehEntry 7 }
cfprVnicDefBehNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DefBeh:nwTemplName managed object property"
::= { cfprVnicDefBehEntry 8 }
cfprVnicDefBehPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DefBeh:policyLevel managed object property"
::= { cfprVnicDefBehEntry 9 }
cfprVnicDefBehPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DefBeh:policyOwner managed object property"
::= { cfprVnicDefBehEntry 10 }
cfprVnicDefBehType OBJECT-TYPE
SYNTAX CfprVnicDefBehType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DefBeh:type managed object property"
::= { cfprVnicDefBehEntry 11 }
cfprVnicDynamicConTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicDynamicConEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon managed object table"
::= { cfprVnicObjects 5 }
cfprVnicDynamicConEntry OBJECT-TYPE
SYNTAX CfprVnicDynamicConEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicDynamicConTable table."
INDEX { cfprVnicDynamicConInstanceId }
::= { cfprVnicDynamicConTable 1 }
CfprVnicDynamicConEntry ::= SEQUENCE {
cfprVnicDynamicConInstanceId CfprManagedObjectId,
cfprVnicDynamicConDn CfprManagedObjectDn,
cfprVnicDynamicConRn SnmpAdminString,
cfprVnicDynamicConAdaptorProfileName SnmpAdminString,
cfprVnicDynamicConDescr SnmpAdminString,
cfprVnicDynamicConDynamicEth Gauge32,
cfprVnicDynamicConIntId SnmpAdminString,
cfprVnicDynamicConMtu Gauge32,
cfprVnicDynamicConName SnmpAdminString,
cfprVnicDynamicConNamingPrefix SnmpAdminString,
cfprVnicDynamicConPolicyLevel Gauge32,
cfprVnicDynamicConPolicyOwner CfprPolicyPolicyOwner,
cfprVnicDynamicConProtection CfprVnicDynamicConReqProtection
}
cfprVnicDynamicConInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicDynamicConEntry 1 }
cfprVnicDynamicConDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:dn managed object property"
::= { cfprVnicDynamicConEntry 2 }
cfprVnicDynamicConRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:rn managed object property"
::= { cfprVnicDynamicConEntry 3 }
cfprVnicDynamicConAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:adaptorProfileName
managed object property"
::= { cfprVnicDynamicConEntry 4 }
cfprVnicDynamicConDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:descr managed object property"
::= { cfprVnicDynamicConEntry 5 }
cfprVnicDynamicConDynamicEth OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:dynamicEth managed
object property"
::= { cfprVnicDynamicConEntry 6 }
cfprVnicDynamicConIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:intId managed object property"
::= { cfprVnicDynamicConEntry 7 }
cfprVnicDynamicConMtu OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:mtu managed object property"
::= { cfprVnicDynamicConEntry 8 }
cfprVnicDynamicConName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:name managed object property"
::= { cfprVnicDynamicConEntry 9 }
cfprVnicDynamicConNamingPrefix OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:namingPrefix managed
object property"
::= { cfprVnicDynamicConEntry 10 }
cfprVnicDynamicConPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:policyLevel managed
object property"
::= { cfprVnicDynamicConEntry 11 }
cfprVnicDynamicConPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:policyOwner managed
object property"
::= { cfprVnicDynamicConEntry 12 }
cfprVnicDynamicConProtection OBJECT-TYPE
SYNTAX CfprVnicDynamicConReqProtection
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicCon:protection managed
object property"
::= { cfprVnicDynamicConEntry 13 }
cfprVnicDynamicConPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicDynamicConPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy managed object table"
::= { cfprVnicObjects 6 }
cfprVnicDynamicConPolicyEntry OBJECT-TYPE
SYNTAX CfprVnicDynamicConPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicDynamicConPolicyTable table."
INDEX { cfprVnicDynamicConPolicyInstanceId }
::= { cfprVnicDynamicConPolicyTable 1 }
CfprVnicDynamicConPolicyEntry ::= SEQUENCE {
cfprVnicDynamicConPolicyInstanceId CfprManagedObjectId,
cfprVnicDynamicConPolicyDn CfprManagedObjectDn,
cfprVnicDynamicConPolicyRn SnmpAdminString,
cfprVnicDynamicConPolicyAdaptorProfileName SnmpAdminString,
cfprVnicDynamicConPolicyDescr SnmpAdminString,
cfprVnicDynamicConPolicyDynamicEth Gauge32,
cfprVnicDynamicConPolicyIntId SnmpAdminString,
cfprVnicDynamicConPolicyMtu Gauge32,
cfprVnicDynamicConPolicyName SnmpAdminString,
cfprVnicDynamicConPolicyNamingPrefix SnmpAdminString,
cfprVnicDynamicConPolicyPolicyLevel Gauge32,
cfprVnicDynamicConPolicyPolicyOwner CfprPolicyPolicyOwner,
cfprVnicDynamicConPolicyProtection CfprVnicDynamicConReqProtection
}
cfprVnicDynamicConPolicyInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicDynamicConPolicyEntry 1 }
cfprVnicDynamicConPolicyDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:dn managed object property"
::= { cfprVnicDynamicConPolicyEntry 2 }
cfprVnicDynamicConPolicyRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:rn managed object property"
::= { cfprVnicDynamicConPolicyEntry 3 }
cfprVnicDynamicConPolicyAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:adaptorProfileName
managed object property"
::= { cfprVnicDynamicConPolicyEntry 4 }
cfprVnicDynamicConPolicyDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:descr managed
object property"
::= { cfprVnicDynamicConPolicyEntry 5 }
cfprVnicDynamicConPolicyDynamicEth OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:dynamicEth
managed object property"
::= { cfprVnicDynamicConPolicyEntry 6 }
cfprVnicDynamicConPolicyIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:intId managed
object property"
::= { cfprVnicDynamicConPolicyEntry 7 }
cfprVnicDynamicConPolicyMtu OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:mtu managed
object property"
::= { cfprVnicDynamicConPolicyEntry 8 }
cfprVnicDynamicConPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:name managed
object property"
::= { cfprVnicDynamicConPolicyEntry 9 }
cfprVnicDynamicConPolicyNamingPrefix OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:namingPrefix
managed object property"
::= { cfprVnicDynamicConPolicyEntry 10 }
cfprVnicDynamicConPolicyPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:policyLevel
managed object property"
::= { cfprVnicDynamicConPolicyEntry 11 }
cfprVnicDynamicConPolicyPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:policyOwner
managed object property"
::= { cfprVnicDynamicConPolicyEntry 12 }
cfprVnicDynamicConPolicyProtection OBJECT-TYPE
SYNTAX CfprVnicDynamicConReqProtection
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicy:protection
managed object property"
::= { cfprVnicDynamicConPolicyEntry 13 }
cfprVnicDynamicConPolicyRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicDynamicConPolicyRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicyRef managed object table"
::= { cfprVnicObjects 7 }
cfprVnicDynamicConPolicyRefEntry OBJECT-TYPE
SYNTAX CfprVnicDynamicConPolicyRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicDynamicConPolicyRefTable table."
INDEX { cfprVnicDynamicConPolicyRefInstanceId }
::= { cfprVnicDynamicConPolicyRefTable 1 }
CfprVnicDynamicConPolicyRefEntry ::= SEQUENCE {
cfprVnicDynamicConPolicyRefInstanceId CfprManagedObjectId,
cfprVnicDynamicConPolicyRefDn CfprManagedObjectDn,
cfprVnicDynamicConPolicyRefRn SnmpAdminString,
cfprVnicDynamicConPolicyRefConPolicyName SnmpAdminString,
cfprVnicDynamicConPolicyRefOperConPolicyName SnmpAdminString
}
cfprVnicDynamicConPolicyRefInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicDynamicConPolicyRefEntry 1 }
cfprVnicDynamicConPolicyRefDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicyRef:dn managed
object property"
::= { cfprVnicDynamicConPolicyRefEntry 2 }
cfprVnicDynamicConPolicyRefRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicyRef:rn managed
object property"
::= { cfprVnicDynamicConPolicyRefEntry 3 }
cfprVnicDynamicConPolicyRefConPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicyRef:conPolicyName
managed object property"
::= { cfprVnicDynamicConPolicyRefEntry 4 }
cfprVnicDynamicConPolicyRefOperConPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicConPolicyRef:operConPolicyName
managed object property"
::= { cfprVnicDynamicConPolicyRefEntry 5 }
cfprVnicDynamicIdUniverseTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicDynamicIdUniverseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicIdUniverse managed object table"
::= { cfprVnicObjects 8 }
cfprVnicDynamicIdUniverseEntry OBJECT-TYPE
SYNTAX CfprVnicDynamicIdUniverseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicDynamicIdUniverseTable table."
INDEX { cfprVnicDynamicIdUniverseInstanceId }
::= { cfprVnicDynamicIdUniverseTable 1 }
CfprVnicDynamicIdUniverseEntry ::= SEQUENCE {
cfprVnicDynamicIdUniverseInstanceId CfprManagedObjectId,
cfprVnicDynamicIdUniverseDn CfprManagedObjectDn,
cfprVnicDynamicIdUniverseRn SnmpAdminString,
cfprVnicDynamicIdUniverseDescr SnmpAdminString,
cfprVnicDynamicIdUniverseIntId SnmpAdminString,
cfprVnicDynamicIdUniverseName SnmpAdminString,
cfprVnicDynamicIdUniversePolicyLevel Gauge32,
cfprVnicDynamicIdUniversePolicyOwner CfprPolicyPolicyOwner
}
cfprVnicDynamicIdUniverseInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicDynamicIdUniverseEntry 1 }
cfprVnicDynamicIdUniverseDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicIdUniverse:dn managed
object property"
::= { cfprVnicDynamicIdUniverseEntry 2 }
cfprVnicDynamicIdUniverseRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicIdUniverse:rn managed
object property"
::= { cfprVnicDynamicIdUniverseEntry 3 }
cfprVnicDynamicIdUniverseDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicIdUniverse:descr managed
object property"
::= { cfprVnicDynamicIdUniverseEntry 4 }
cfprVnicDynamicIdUniverseIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicIdUniverse:intId managed
object property"
::= { cfprVnicDynamicIdUniverseEntry 5 }
cfprVnicDynamicIdUniverseName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicIdUniverse:name managed
object property"
::= { cfprVnicDynamicIdUniverseEntry 6 }
cfprVnicDynamicIdUniversePolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicIdUniverse:policyLevel
managed object property"
::= { cfprVnicDynamicIdUniverseEntry 7 }
cfprVnicDynamicIdUniversePolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicIdUniverse:policyOwner
managed object property"
::= { cfprVnicDynamicIdUniverseEntry 8 }
cfprVnicDynamicProviderTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicDynamicProviderEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicProvider managed object table"
::= { cfprVnicObjects 9 }
cfprVnicDynamicProviderEntry OBJECT-TYPE
SYNTAX CfprVnicDynamicProviderEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicDynamicProviderTable table."
INDEX { cfprVnicDynamicProviderInstanceId }
::= { cfprVnicDynamicProviderTable 1 }
CfprVnicDynamicProviderEntry ::= SEQUENCE {
cfprVnicDynamicProviderInstanceId CfprManagedObjectId,
cfprVnicDynamicProviderDn CfprManagedObjectDn,
cfprVnicDynamicProviderRn SnmpAdminString,
cfprVnicDynamicProviderName SnmpAdminString
}
cfprVnicDynamicProviderInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicDynamicProviderEntry 1 }
cfprVnicDynamicProviderDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicProvider:dn managed object property"
::= { cfprVnicDynamicProviderEntry 2 }
cfprVnicDynamicProviderRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicProvider:rn managed object property"
::= { cfprVnicDynamicProviderEntry 3 }
cfprVnicDynamicProviderName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicProvider:name managed
object property"
::= { cfprVnicDynamicProviderEntry 4 }
cfprVnicDynamicProviderEpTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicDynamicProviderEpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicProviderEp managed object table"
::= { cfprVnicObjects 10 }
cfprVnicDynamicProviderEpEntry OBJECT-TYPE
SYNTAX CfprVnicDynamicProviderEpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicDynamicProviderEpTable table."
INDEX { cfprVnicDynamicProviderEpInstanceId }
::= { cfprVnicDynamicProviderEpTable 1 }
CfprVnicDynamicProviderEpEntry ::= SEQUENCE {
cfprVnicDynamicProviderEpInstanceId CfprManagedObjectId,
cfprVnicDynamicProviderEpDn CfprManagedObjectDn,
cfprVnicDynamicProviderEpRn SnmpAdminString,
cfprVnicDynamicProviderEpChassisId Gauge32,
cfprVnicDynamicProviderEpPortId Gauge32,
cfprVnicDynamicProviderEpSlotId Gauge32,
cfprVnicDynamicProviderEpSwitchId CfprNetworkSwitchId
}
cfprVnicDynamicProviderEpInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicDynamicProviderEpEntry 1 }
cfprVnicDynamicProviderEpDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicProviderEp:dn managed
object property"
::= { cfprVnicDynamicProviderEpEntry 2 }
cfprVnicDynamicProviderEpRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicProviderEp:rn managed
object property"
::= { cfprVnicDynamicProviderEpEntry 3 }
cfprVnicDynamicProviderEpChassisId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicProviderEp:chassisId
managed object property"
::= { cfprVnicDynamicProviderEpEntry 4 }
cfprVnicDynamicProviderEpPortId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicProviderEp:portId
managed object property"
::= { cfprVnicDynamicProviderEpEntry 5 }
cfprVnicDynamicProviderEpSlotId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicProviderEp:slotId
managed object property"
::= { cfprVnicDynamicProviderEpEntry 6 }
cfprVnicDynamicProviderEpSwitchId OBJECT-TYPE
SYNTAX CfprNetworkSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:DynamicProviderEp:switchId
managed object property"
::= { cfprVnicDynamicProviderEpEntry 7 }
cfprVnicEthLifTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicEthLifEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EthLif managed object table"
::= { cfprVnicObjects 11 }
cfprVnicEthLifEntry OBJECT-TYPE
SYNTAX CfprVnicEthLifEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicEthLifTable table."
INDEX { cfprVnicEthLifInstanceId }
::= { cfprVnicEthLifTable 1 }
CfprVnicEthLifEntry ::= SEQUENCE {
cfprVnicEthLifInstanceId CfprManagedObjectId,
cfprVnicEthLifDn CfprManagedObjectDn,
cfprVnicEthLifRn SnmpAdminString,
cfprVnicEthLifAddr MacAddress,
cfprVnicEthLifName SnmpAdminString,
cfprVnicEthLifNicDn SnmpAdminString,
cfprVnicEthLifOwner CfprVnicConnectionOwner,
cfprVnicEthLifSwitchId CfprNetworkSwitchId,
cfprVnicEthLifType CfprVnicConnectionType,
cfprVnicEthLifVnicDn SnmpAdminString
}
cfprVnicEthLifInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicEthLifEntry 1 }
cfprVnicEthLifDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EthLif:dn managed object property"
::= { cfprVnicEthLifEntry 2 }
cfprVnicEthLifRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EthLif:rn managed object property"
::= { cfprVnicEthLifEntry 3 }
cfprVnicEthLifAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EthLif:addr managed object property"
::= { cfprVnicEthLifEntry 4 }
cfprVnicEthLifName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EthLif:name managed object property"
::= { cfprVnicEthLifEntry 5 }
cfprVnicEthLifNicDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EthLif:nicDn managed object property"
::= { cfprVnicEthLifEntry 6 }
cfprVnicEthLifOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EthLif:owner managed object property"
::= { cfprVnicEthLifEntry 7 }
cfprVnicEthLifSwitchId OBJECT-TYPE
SYNTAX CfprNetworkSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EthLif:switchId managed object property"
::= { cfprVnicEthLifEntry 8 }
cfprVnicEthLifType OBJECT-TYPE
SYNTAX CfprVnicConnectionType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EthLif:type managed object property"
::= { cfprVnicEthLifEntry 9 }
cfprVnicEthLifVnicDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EthLif:vnicDn managed object property"
::= { cfprVnicEthLifEntry 10 }
cfprVnicEtherTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicEtherEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether managed object table"
::= { cfprVnicObjects 12 }
cfprVnicEtherEntry OBJECT-TYPE
SYNTAX CfprVnicEtherEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicEtherTable table."
INDEX { cfprVnicEtherInstanceId }
::= { cfprVnicEtherTable 1 }
CfprVnicEtherEntry ::= SEQUENCE {
cfprVnicEtherInstanceId CfprManagedObjectId,
cfprVnicEtherDn CfprManagedObjectDn,
cfprVnicEtherRn SnmpAdminString,
cfprVnicEtherAdaptorProfileName SnmpAdminString,
cfprVnicEtherAddr MacAddress,
cfprVnicEtherAdminHostPort CfprFabricHostPortId,
cfprVnicEtherAdminVcon SnmpAdminString,
cfprVnicEtherAppInstId SnmpAdminString,
cfprVnicEtherAppRole CfprVnicAppRole,
cfprVnicEtherBootDev CfprVnicVnicBootDev,
cfprVnicEtherConfigQualifier CfprVnicConfigIssues,
cfprVnicEtherConfigState CfprLsConfigState,
cfprVnicEtherDynamicId Gauge32,
cfprVnicEtherEquipmentDn SnmpAdminString,
cfprVnicEtherFltAggr Unsigned64,
cfprVnicEtherIdentPoolName SnmpAdminString,
cfprVnicEtherInstType CfprVnicInstantiation,
cfprVnicEtherIsAllocated TruthValue,
cfprVnicEtherMtu Gauge32,
cfprVnicEtherName SnmpAdminString,
cfprVnicEtherNwCtrlPolicyName SnmpAdminString,
cfprVnicEtherNwTemplName SnmpAdminString,
cfprVnicEtherOperAdaptorProfileName SnmpAdminString,
cfprVnicEtherOperHostPort CfprVnicVnicOperHostPort,
cfprVnicEtherOperIdentPoolName SnmpAdminString,
cfprVnicEtherOperNwCtrlPolicyName SnmpAdminString,
cfprVnicEtherOperNwTemplName SnmpAdminString,
cfprVnicEtherOperOrder Gauge32,
cfprVnicEtherOperPinToGroupName SnmpAdminString,
cfprVnicEtherOperQosPolicyName SnmpAdminString,
cfprVnicEtherOperSpeed Gauge32,
cfprVnicEtherOperStatsPolicyName SnmpAdminString,
cfprVnicEtherOperVcon SnmpAdminString,
cfprVnicEtherOrder Gauge32,
cfprVnicEtherOwner CfprVnicConnectionOwner,
cfprVnicEtherPfDn SnmpAdminString,
cfprVnicEtherPinToGroupName SnmpAdminString,
cfprVnicEtherQosPolicyName SnmpAdminString,
cfprVnicEtherStatsPolicyName SnmpAdminString,
cfprVnicEtherSwitchId CfprVnicEtherBaseSwitchId,
cfprVnicEtherType CfprVnicEtherType,
cfprVnicEtherVirtualizationPreference CfprVnicVirtualizationPreferenceType,
cfprVnicEtherPortType CfprFabricSSAPortType
}
cfprVnicEtherInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicEtherEntry 1 }
cfprVnicEtherDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:dn managed object property"
::= { cfprVnicEtherEntry 2 }
cfprVnicEtherRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:rn managed object property"
::= { cfprVnicEtherEntry 3 }
cfprVnicEtherAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:adaptorProfileName
managed object property"
::= { cfprVnicEtherEntry 4 }
cfprVnicEtherAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:addr managed object property"
::= { cfprVnicEtherEntry 5 }
cfprVnicEtherAdminHostPort OBJECT-TYPE
SYNTAX CfprFabricHostPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:adminHostPort managed object property"
::= { cfprVnicEtherEntry 6 }
cfprVnicEtherAdminVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:adminVcon managed object property"
::= { cfprVnicEtherEntry 7 }
cfprVnicEtherAppInstId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:appInstId managed object property"
::= { cfprVnicEtherEntry 8 }
cfprVnicEtherAppRole OBJECT-TYPE
SYNTAX CfprVnicAppRole
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:appRole managed object property"
::= { cfprVnicEtherEntry 9 }
cfprVnicEtherBootDev OBJECT-TYPE
SYNTAX CfprVnicVnicBootDev
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:bootDev managed object property"
::= { cfprVnicEtherEntry 10 }
cfprVnicEtherConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:configQualifier managed
object property"
::= { cfprVnicEtherEntry 11 }
cfprVnicEtherConfigState OBJECT-TYPE
SYNTAX CfprLsConfigState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:configState managed object property"
::= { cfprVnicEtherEntry 12 }
cfprVnicEtherDynamicId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:dynamicId managed object property"
::= { cfprVnicEtherEntry 13 }
cfprVnicEtherEquipmentDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:equipmentDn managed object property"
::= { cfprVnicEtherEntry 14 }
cfprVnicEtherFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:fltAggr managed object property"
::= { cfprVnicEtherEntry 15 }
cfprVnicEtherIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:identPoolName managed object property"
::= { cfprVnicEtherEntry 16 }
cfprVnicEtherInstType OBJECT-TYPE
SYNTAX CfprVnicInstantiation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:instType managed object property"
::= { cfprVnicEtherEntry 17 }
cfprVnicEtherIsAllocated OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:isAllocated managed object property"
::= { cfprVnicEtherEntry 18 }
cfprVnicEtherMtu OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:mtu managed object property"
::= { cfprVnicEtherEntry 19 }
cfprVnicEtherName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:name managed object property"
::= { cfprVnicEtherEntry 20 }
cfprVnicEtherNwCtrlPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:nwCtrlPolicyName managed
object property"
::= { cfprVnicEtherEntry 21 }
cfprVnicEtherNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:nwTemplName managed object property"
::= { cfprVnicEtherEntry 22 }
cfprVnicEtherOperAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:operAdaptorProfileName
managed object property"
::= { cfprVnicEtherEntry 23 }
cfprVnicEtherOperHostPort OBJECT-TYPE
SYNTAX CfprVnicVnicOperHostPort
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:operHostPort managed object property"
::= { cfprVnicEtherEntry 24 }
cfprVnicEtherOperIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:operIdentPoolName managed
object property"
::= { cfprVnicEtherEntry 25 }
cfprVnicEtherOperNwCtrlPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:operNwCtrlPolicyName
managed object property"
::= { cfprVnicEtherEntry 26 }
cfprVnicEtherOperNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:operNwTemplName managed
object property"
::= { cfprVnicEtherEntry 27 }
cfprVnicEtherOperOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:operOrder managed object property"
::= { cfprVnicEtherEntry 28 }
cfprVnicEtherOperPinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:operPinToGroupName
managed object property"
::= { cfprVnicEtherEntry 29 }
cfprVnicEtherOperQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:operQosPolicyName managed
object property"
::= { cfprVnicEtherEntry 30 }
cfprVnicEtherOperSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:operSpeed managed object property"
::= { cfprVnicEtherEntry 31 }
cfprVnicEtherOperStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:operStatsPolicyName
managed object property"
::= { cfprVnicEtherEntry 32 }
cfprVnicEtherOperVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:operVcon managed object property"
::= { cfprVnicEtherEntry 33 }
cfprVnicEtherOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:order managed object property"
::= { cfprVnicEtherEntry 34 }
cfprVnicEtherOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:owner managed object property"
::= { cfprVnicEtherEntry 35 }
cfprVnicEtherPfDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:pfDn managed object property"
::= { cfprVnicEtherEntry 36 }
cfprVnicEtherPinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:pinToGroupName managed
object property"
::= { cfprVnicEtherEntry 37 }
cfprVnicEtherQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:qosPolicyName managed object property"
::= { cfprVnicEtherEntry 38 }
cfprVnicEtherStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:statsPolicyName managed
object property"
::= { cfprVnicEtherEntry 39 }
cfprVnicEtherSwitchId OBJECT-TYPE
SYNTAX CfprVnicEtherBaseSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:switchId managed object property"
::= { cfprVnicEtherEntry 40 }
cfprVnicEtherType OBJECT-TYPE
SYNTAX CfprVnicEtherType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:type managed object property"
::= { cfprVnicEtherEntry 41 }
cfprVnicEtherVirtualizationPreference OBJECT-TYPE
SYNTAX CfprVnicVirtualizationPreferenceType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:virtualizationPreference
managed object property"
::= { cfprVnicEtherEntry 42 }
cfprVnicEtherPortType OBJECT-TYPE
SYNTAX CfprFabricSSAPortType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ether:portType managed object property"
::= { cfprVnicEtherEntry 43 }
cfprVnicEtherIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicEtherIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf managed object table"
::= { cfprVnicObjects 13 }
cfprVnicEtherIfEntry OBJECT-TYPE
SYNTAX CfprVnicEtherIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicEtherIfTable table."
INDEX { cfprVnicEtherIfInstanceId }
::= { cfprVnicEtherIfTable 1 }
CfprVnicEtherIfEntry ::= SEQUENCE {
cfprVnicEtherIfInstanceId CfprManagedObjectId,
cfprVnicEtherIfDn CfprManagedObjectDn,
cfprVnicEtherIfRn SnmpAdminString,
cfprVnicEtherIfAddr MacAddress,
cfprVnicEtherIfConfigQualifier CfprVnicConfigIssues,
cfprVnicEtherIfDefaultNet TruthValue,
cfprVnicEtherIfFltAggr Unsigned64,
cfprVnicEtherIfName SnmpAdminString,
cfprVnicEtherIfOperState CfprVnicIfOperState,
cfprVnicEtherIfOperVnetDn SnmpAdminString,
cfprVnicEtherIfOperVnetName SnmpAdminString,
cfprVnicEtherIfOwner CfprVnicConnectionOwner,
cfprVnicEtherIfPubNwId Gauge32,
cfprVnicEtherIfSharing CfprFabricVlanSharingType,
cfprVnicEtherIfSwitchId CfprVnicL2IfSwitchId,
cfprVnicEtherIfType CfprVnicAEtherIfType,
cfprVnicEtherIfVnet Gauge32
}
cfprVnicEtherIfInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicEtherIfEntry 1 }
cfprVnicEtherIfDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:dn managed object property"
::= { cfprVnicEtherIfEntry 2 }
cfprVnicEtherIfRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:rn managed object property"
::= { cfprVnicEtherIfEntry 3 }
cfprVnicEtherIfAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:addr managed object property"
::= { cfprVnicEtherIfEntry 4 }
cfprVnicEtherIfConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:configQualifier managed
object property"
::= { cfprVnicEtherIfEntry 5 }
cfprVnicEtherIfDefaultNet OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:defaultNet managed object property"
::= { cfprVnicEtherIfEntry 6 }
cfprVnicEtherIfFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:fltAggr managed object property"
::= { cfprVnicEtherIfEntry 7 }
cfprVnicEtherIfName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:name managed object property"
::= { cfprVnicEtherIfEntry 8 }
cfprVnicEtherIfOperState OBJECT-TYPE
SYNTAX CfprVnicIfOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:operState managed object property"
::= { cfprVnicEtherIfEntry 9 }
cfprVnicEtherIfOperVnetDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:operVnetDn managed object property"
::= { cfprVnicEtherIfEntry 10 }
cfprVnicEtherIfOperVnetName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:operVnetName managed
object property"
::= { cfprVnicEtherIfEntry 11 }
cfprVnicEtherIfOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:owner managed object property"
::= { cfprVnicEtherIfEntry 12 }
cfprVnicEtherIfPubNwId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:pubNwId managed object property"
::= { cfprVnicEtherIfEntry 13 }
cfprVnicEtherIfSharing OBJECT-TYPE
SYNTAX CfprFabricVlanSharingType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:sharing managed object property"
::= { cfprVnicEtherIfEntry 14 }
cfprVnicEtherIfSwitchId OBJECT-TYPE
SYNTAX CfprVnicL2IfSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:switchId managed object property"
::= { cfprVnicEtherIfEntry 15 }
cfprVnicEtherIfType OBJECT-TYPE
SYNTAX CfprVnicAEtherIfType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:type managed object property"
::= { cfprVnicEtherIfEntry 16 }
cfprVnicEtherIfVnet OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:EtherIf:vnet managed object property"
::= { cfprVnicEtherIfEntry 17 }
cfprVnicFcTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicFcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc managed object table"
::= { cfprVnicObjects 14 }
cfprVnicFcEntry OBJECT-TYPE
SYNTAX CfprVnicFcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicFcTable table."
INDEX { cfprVnicFcInstanceId }
::= { cfprVnicFcTable 1 }
CfprVnicFcEntry ::= SEQUENCE {
cfprVnicFcInstanceId CfprManagedObjectId,
cfprVnicFcDn CfprManagedObjectDn,
cfprVnicFcRn SnmpAdminString,
cfprVnicFcAdaptorProfileName SnmpAdminString,
cfprVnicFcAddr Unsigned64,
cfprVnicFcAdminHostPort CfprFabricHostPortId,
cfprVnicFcAdminVcon SnmpAdminString,
cfprVnicFcAppRole CfprVnicAppRole,
cfprVnicFcBootDev CfprVnicVnicBootDev,
cfprVnicFcConfigQualifier CfprVnicConfigIssues,
cfprVnicFcConfigState CfprLsConfigState,
cfprVnicFcEquipmentDn SnmpAdminString,
cfprVnicFcFltAggr Unsigned64,
cfprVnicFcIdentPoolName SnmpAdminString,
cfprVnicFcInstType CfprVnicInstantiation,
cfprVnicFcMaxDataFieldSize Gauge32,
cfprVnicFcName SnmpAdminString,
cfprVnicFcNodeAddr Unsigned64,
cfprVnicFcNwTemplName SnmpAdminString,
cfprVnicFcOperAdaptorProfileName SnmpAdminString,
cfprVnicFcOperHostPort CfprVnicVnicOperHostPort,
cfprVnicFcOperIdentPoolName SnmpAdminString,
cfprVnicFcOperNwTemplName SnmpAdminString,
cfprVnicFcOperOrder Gauge32,
cfprVnicFcOperPinToGroupName SnmpAdminString,
cfprVnicFcOperQosPolicyName SnmpAdminString,
cfprVnicFcOperSpeed Gauge32,
cfprVnicFcOperStatsPolicyName SnmpAdminString,
cfprVnicFcOperVcon SnmpAdminString,
cfprVnicFcOrder Gauge32,
cfprVnicFcOwner CfprVnicConnectionOwner,
cfprVnicFcPersBind CfprVnicFcBasePersBind,
cfprVnicFcPersBindClear TruthValue,
cfprVnicFcPinToGroupName SnmpAdminString,
cfprVnicFcQosPolicyName SnmpAdminString,
cfprVnicFcStatsPolicyName SnmpAdminString,
cfprVnicFcSwitchId CfprNetworkSwitchId,
cfprVnicFcType CfprVnicFcBaseType
}
cfprVnicFcInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicFcEntry 1 }
cfprVnicFcDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:dn managed object property"
::= { cfprVnicFcEntry 2 }
cfprVnicFcRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:rn managed object property"
::= { cfprVnicFcEntry 3 }
cfprVnicFcAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:adaptorProfileName managed
object property"
::= { cfprVnicFcEntry 4 }
cfprVnicFcAddr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:addr managed object property"
::= { cfprVnicFcEntry 5 }
cfprVnicFcAdminHostPort OBJECT-TYPE
SYNTAX CfprFabricHostPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:adminHostPort managed object property"
::= { cfprVnicFcEntry 6 }
cfprVnicFcAdminVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:adminVcon managed object property"
::= { cfprVnicFcEntry 7 }
cfprVnicFcAppRole OBJECT-TYPE
SYNTAX CfprVnicAppRole
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:appRole managed object property"
::= { cfprVnicFcEntry 8 }
cfprVnicFcBootDev OBJECT-TYPE
SYNTAX CfprVnicVnicBootDev
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:bootDev managed object property"
::= { cfprVnicFcEntry 9 }
cfprVnicFcConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:configQualifier managed object property"
::= { cfprVnicFcEntry 10 }
cfprVnicFcConfigState OBJECT-TYPE
SYNTAX CfprLsConfigState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:configState managed object property"
::= { cfprVnicFcEntry 11 }
cfprVnicFcEquipmentDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:equipmentDn managed object property"
::= { cfprVnicFcEntry 12 }
cfprVnicFcFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:fltAggr managed object property"
::= { cfprVnicFcEntry 13 }
cfprVnicFcIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:identPoolName managed object property"
::= { cfprVnicFcEntry 14 }
cfprVnicFcInstType OBJECT-TYPE
SYNTAX CfprVnicInstantiation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:instType managed object property"
::= { cfprVnicFcEntry 15 }
cfprVnicFcMaxDataFieldSize OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:maxDataFieldSize managed object property"
::= { cfprVnicFcEntry 16 }
cfprVnicFcName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:name managed object property"
::= { cfprVnicFcEntry 17 }
cfprVnicFcNodeAddr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:nodeAddr managed object property"
::= { cfprVnicFcEntry 18 }
cfprVnicFcNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:nwTemplName managed object property"
::= { cfprVnicFcEntry 19 }
cfprVnicFcOperAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:operAdaptorProfileName
managed object property"
::= { cfprVnicFcEntry 20 }
cfprVnicFcOperHostPort OBJECT-TYPE
SYNTAX CfprVnicVnicOperHostPort
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:operHostPort managed object property"
::= { cfprVnicFcEntry 21 }
cfprVnicFcOperIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:operIdentPoolName managed
object property"
::= { cfprVnicFcEntry 22 }
cfprVnicFcOperNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:operNwTemplName managed object property"
::= { cfprVnicFcEntry 23 }
cfprVnicFcOperOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:operOrder managed object property"
::= { cfprVnicFcEntry 24 }
cfprVnicFcOperPinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:operPinToGroupName managed
object property"
::= { cfprVnicFcEntry 25 }
cfprVnicFcOperQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:operQosPolicyName managed
object property"
::= { cfprVnicFcEntry 26 }
cfprVnicFcOperSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:operSpeed managed object property"
::= { cfprVnicFcEntry 27 }
cfprVnicFcOperStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:operStatsPolicyName managed
object property"
::= { cfprVnicFcEntry 28 }
cfprVnicFcOperVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:operVcon managed object property"
::= { cfprVnicFcEntry 29 }
cfprVnicFcOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:order managed object property"
::= { cfprVnicFcEntry 30 }
cfprVnicFcOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:owner managed object property"
::= { cfprVnicFcEntry 31 }
cfprVnicFcPersBind OBJECT-TYPE
SYNTAX CfprVnicFcBasePersBind
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:persBind managed object property"
::= { cfprVnicFcEntry 32 }
cfprVnicFcPersBindClear OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:persBindClear managed object property"
::= { cfprVnicFcEntry 33 }
cfprVnicFcPinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:pinToGroupName managed object property"
::= { cfprVnicFcEntry 34 }
cfprVnicFcQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:qosPolicyName managed object property"
::= { cfprVnicFcEntry 35 }
cfprVnicFcStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:statsPolicyName managed object property"
::= { cfprVnicFcEntry 36 }
cfprVnicFcSwitchId OBJECT-TYPE
SYNTAX CfprNetworkSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:switchId managed object property"
::= { cfprVnicFcEntry 37 }
cfprVnicFcType OBJECT-TYPE
SYNTAX CfprVnicFcBaseType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Fc:type managed object property"
::= { cfprVnicFcEntry 38 }
cfprVnicFcGroupDefTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicFcGroupDefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef managed object table"
::= { cfprVnicObjects 15 }
cfprVnicFcGroupDefEntry OBJECT-TYPE
SYNTAX CfprVnicFcGroupDefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicFcGroupDefTable table."
INDEX { cfprVnicFcGroupDefInstanceId }
::= { cfprVnicFcGroupDefTable 1 }
CfprVnicFcGroupDefEntry ::= SEQUENCE {
cfprVnicFcGroupDefInstanceId CfprManagedObjectId,
cfprVnicFcGroupDefDn CfprManagedObjectDn,
cfprVnicFcGroupDefRn SnmpAdminString,
cfprVnicFcGroupDefAdaptorProfileName SnmpAdminString,
cfprVnicFcGroupDefDescr SnmpAdminString,
cfprVnicFcGroupDefIdentPoolName SnmpAdminString,
cfprVnicFcGroupDefIntId SnmpAdminString,
cfprVnicFcGroupDefMaxDataFieldSize Gauge32,
cfprVnicFcGroupDefName SnmpAdminString,
cfprVnicFcGroupDefNwTemplName SnmpAdminString,
cfprVnicFcGroupDefOperStatsPolicyName SnmpAdminString,
cfprVnicFcGroupDefOperStorageConnPolicyName SnmpAdminString,
cfprVnicFcGroupDefPolicyLevel Gauge32,
cfprVnicFcGroupDefPolicyOwner CfprPolicyPolicyOwner,
cfprVnicFcGroupDefQosPolicyName SnmpAdminString,
cfprVnicFcGroupDefStatsPolicyName SnmpAdminString,
cfprVnicFcGroupDefStorageConnPolicyName SnmpAdminString
}
cfprVnicFcGroupDefInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicFcGroupDefEntry 1 }
cfprVnicFcGroupDefDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:dn managed object property"
::= { cfprVnicFcGroupDefEntry 2 }
cfprVnicFcGroupDefRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:rn managed object property"
::= { cfprVnicFcGroupDefEntry 3 }
cfprVnicFcGroupDefAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:adaptorProfileName
managed object property"
::= { cfprVnicFcGroupDefEntry 4 }
cfprVnicFcGroupDefDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:descr managed object property"
::= { cfprVnicFcGroupDefEntry 5 }
cfprVnicFcGroupDefIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:identPoolName
managed object property"
::= { cfprVnicFcGroupDefEntry 6 }
cfprVnicFcGroupDefIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:intId managed object property"
::= { cfprVnicFcGroupDefEntry 7 }
cfprVnicFcGroupDefMaxDataFieldSize OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:maxDataFieldSize
managed object property"
::= { cfprVnicFcGroupDefEntry 8 }
cfprVnicFcGroupDefName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:name managed object property"
::= { cfprVnicFcGroupDefEntry 9 }
cfprVnicFcGroupDefNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:nwTemplName managed
object property"
::= { cfprVnicFcGroupDefEntry 10 }
cfprVnicFcGroupDefOperStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:operStatsPolicyName
managed object property"
::= { cfprVnicFcGroupDefEntry 11 }
cfprVnicFcGroupDefOperStorageConnPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:operStorageConnPolicyName
managed object property"
::= { cfprVnicFcGroupDefEntry 12 }
cfprVnicFcGroupDefPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:policyLevel managed
object property"
::= { cfprVnicFcGroupDefEntry 13 }
cfprVnicFcGroupDefPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:policyOwner managed
object property"
::= { cfprVnicFcGroupDefEntry 14 }
cfprVnicFcGroupDefQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:qosPolicyName
managed object property"
::= { cfprVnicFcGroupDefEntry 15 }
cfprVnicFcGroupDefStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:statsPolicyName
managed object property"
::= { cfprVnicFcGroupDefEntry 16 }
cfprVnicFcGroupDefStorageConnPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupDef:storageConnPolicyName
managed object property"
::= { cfprVnicFcGroupDefEntry 17 }
cfprVnicFcGroupTemplTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicFcGroupTemplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl managed object table"
::= { cfprVnicObjects 16 }
cfprVnicFcGroupTemplEntry OBJECT-TYPE
SYNTAX CfprVnicFcGroupTemplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicFcGroupTemplTable table."
INDEX { cfprVnicFcGroupTemplInstanceId }
::= { cfprVnicFcGroupTemplTable 1 }
CfprVnicFcGroupTemplEntry ::= SEQUENCE {
cfprVnicFcGroupTemplInstanceId CfprManagedObjectId,
cfprVnicFcGroupTemplDn CfprManagedObjectDn,
cfprVnicFcGroupTemplRn SnmpAdminString,
cfprVnicFcGroupTemplAdaptorProfileName SnmpAdminString,
cfprVnicFcGroupTemplDescr SnmpAdminString,
cfprVnicFcGroupTemplIdentPoolName SnmpAdminString,
cfprVnicFcGroupTemplIntId SnmpAdminString,
cfprVnicFcGroupTemplMaxDataFieldSize Gauge32,
cfprVnicFcGroupTemplName SnmpAdminString,
cfprVnicFcGroupTemplNwTemplName SnmpAdminString,
cfprVnicFcGroupTemplOperStatsPolicyName SnmpAdminString,
cfprVnicFcGroupTemplOperStorageConnPolicyName SnmpAdminString,
cfprVnicFcGroupTemplPolicyLevel Gauge32,
cfprVnicFcGroupTemplPolicyOwner CfprPolicyPolicyOwner,
cfprVnicFcGroupTemplQosPolicyName SnmpAdminString,
cfprVnicFcGroupTemplStatsPolicyName SnmpAdminString,
cfprVnicFcGroupTemplStorageConnPolicyName SnmpAdminString,
cfprVnicFcGroupTemplTemplType CfprVnicTemplateType
}
cfprVnicFcGroupTemplInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicFcGroupTemplEntry 1 }
cfprVnicFcGroupTemplDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:dn managed object property"
::= { cfprVnicFcGroupTemplEntry 2 }
cfprVnicFcGroupTemplRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:rn managed object property"
::= { cfprVnicFcGroupTemplEntry 3 }
cfprVnicFcGroupTemplAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:adaptorProfileName
managed object property"
::= { cfprVnicFcGroupTemplEntry 4 }
cfprVnicFcGroupTemplDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:descr managed object property"
::= { cfprVnicFcGroupTemplEntry 5 }
cfprVnicFcGroupTemplIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:identPoolName
managed object property"
::= { cfprVnicFcGroupTemplEntry 6 }
cfprVnicFcGroupTemplIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:intId managed object property"
::= { cfprVnicFcGroupTemplEntry 7 }
cfprVnicFcGroupTemplMaxDataFieldSize OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:maxDataFieldSize
managed object property"
::= { cfprVnicFcGroupTemplEntry 8 }
cfprVnicFcGroupTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:name managed object property"
::= { cfprVnicFcGroupTemplEntry 9 }
cfprVnicFcGroupTemplNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:nwTemplName
managed object property"
::= { cfprVnicFcGroupTemplEntry 10 }
cfprVnicFcGroupTemplOperStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:operStatsPolicyName
managed object property"
::= { cfprVnicFcGroupTemplEntry 11 }
cfprVnicFcGroupTemplOperStorageConnPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:operStorageConnPolicyName
managed object property"
::= { cfprVnicFcGroupTemplEntry 12 }
cfprVnicFcGroupTemplPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:policyLevel
managed object property"
::= { cfprVnicFcGroupTemplEntry 13 }
cfprVnicFcGroupTemplPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:policyOwner
managed object property"
::= { cfprVnicFcGroupTemplEntry 14 }
cfprVnicFcGroupTemplQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:qosPolicyName
managed object property"
::= { cfprVnicFcGroupTemplEntry 15 }
cfprVnicFcGroupTemplStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:statsPolicyName
managed object property"
::= { cfprVnicFcGroupTemplEntry 16 }
cfprVnicFcGroupTemplStorageConnPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:storageConnPolicyName
managed object property"
::= { cfprVnicFcGroupTemplEntry 17 }
cfprVnicFcGroupTemplTemplType OBJECT-TYPE
SYNTAX CfprVnicTemplateType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcGroupTempl:templType managed
object property"
::= { cfprVnicFcGroupTemplEntry 18 }
cfprVnicFcIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicFcIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf managed object table"
::= { cfprVnicObjects 17 }
cfprVnicFcIfEntry OBJECT-TYPE
SYNTAX CfprVnicFcIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicFcIfTable table."
INDEX { cfprVnicFcIfInstanceId }
::= { cfprVnicFcIfTable 1 }
CfprVnicFcIfEntry ::= SEQUENCE {
cfprVnicFcIfInstanceId CfprManagedObjectId,
cfprVnicFcIfDn CfprManagedObjectDn,
cfprVnicFcIfRn SnmpAdminString,
cfprVnicFcIfConfigQualifier CfprVnicConfigIssues,
cfprVnicFcIfInitiator Unsigned64,
cfprVnicFcIfName SnmpAdminString,
cfprVnicFcIfOperState CfprVnicIfOperState,
cfprVnicFcIfOperVnetDn SnmpAdminString,
cfprVnicFcIfOperVnetName SnmpAdminString,
cfprVnicFcIfOwner CfprVnicConnectionOwner,
cfprVnicFcIfPubNwId Gauge32,
cfprVnicFcIfSharing CfprFabricVlanSharingType,
cfprVnicFcIfSwitchId CfprVnicL2IfSwitchId,
cfprVnicFcIfType CfprVnicAFcIfType,
cfprVnicFcIfVnet Gauge32
}
cfprVnicFcIfInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicFcIfEntry 1 }
cfprVnicFcIfDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:dn managed object property"
::= { cfprVnicFcIfEntry 2 }
cfprVnicFcIfRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:rn managed object property"
::= { cfprVnicFcIfEntry 3 }
cfprVnicFcIfConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:configQualifier managed
object property"
::= { cfprVnicFcIfEntry 4 }
cfprVnicFcIfInitiator OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:initiator managed object property"
::= { cfprVnicFcIfEntry 5 }
cfprVnicFcIfName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:name managed object property"
::= { cfprVnicFcIfEntry 6 }
cfprVnicFcIfOperState OBJECT-TYPE
SYNTAX CfprVnicIfOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:operState managed object property"
::= { cfprVnicFcIfEntry 7 }
cfprVnicFcIfOperVnetDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:operVnetDn managed object property"
::= { cfprVnicFcIfEntry 8 }
cfprVnicFcIfOperVnetName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:operVnetName managed object property"
::= { cfprVnicFcIfEntry 9 }
cfprVnicFcIfOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:owner managed object property"
::= { cfprVnicFcIfEntry 10 }
cfprVnicFcIfPubNwId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:pubNwId managed object property"
::= { cfprVnicFcIfEntry 11 }
cfprVnicFcIfSharing OBJECT-TYPE
SYNTAX CfprFabricVlanSharingType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:sharing managed object property"
::= { cfprVnicFcIfEntry 12 }
cfprVnicFcIfSwitchId OBJECT-TYPE
SYNTAX CfprVnicL2IfSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:switchId managed object property"
::= { cfprVnicFcIfEntry 13 }
cfprVnicFcIfType OBJECT-TYPE
SYNTAX CfprVnicAFcIfType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:type managed object property"
::= { cfprVnicFcIfEntry 14 }
cfprVnicFcIfVnet OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcIf:vnet managed object property"
::= { cfprVnicFcIfEntry 15 }
cfprVnicFcLifTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicFcLifEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcLif managed object table"
::= { cfprVnicObjects 18 }
cfprVnicFcLifEntry OBJECT-TYPE
SYNTAX CfprVnicFcLifEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicFcLifTable table."
INDEX { cfprVnicFcLifInstanceId }
::= { cfprVnicFcLifTable 1 }
CfprVnicFcLifEntry ::= SEQUENCE {
cfprVnicFcLifInstanceId CfprManagedObjectId,
cfprVnicFcLifDn CfprManagedObjectDn,
cfprVnicFcLifRn SnmpAdminString,
cfprVnicFcLifAddr Unsigned64,
cfprVnicFcLifName SnmpAdminString,
cfprVnicFcLifNicDn SnmpAdminString,
cfprVnicFcLifOwner CfprVnicConnectionOwner,
cfprVnicFcLifSwitchId CfprNetworkSwitchId,
cfprVnicFcLifType CfprVnicConnectionType,
cfprVnicFcLifVnicDn SnmpAdminString
}
cfprVnicFcLifInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicFcLifEntry 1 }
cfprVnicFcLifDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcLif:dn managed object property"
::= { cfprVnicFcLifEntry 2 }
cfprVnicFcLifRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcLif:rn managed object property"
::= { cfprVnicFcLifEntry 3 }
cfprVnicFcLifAddr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcLif:addr managed object property"
::= { cfprVnicFcLifEntry 4 }
cfprVnicFcLifName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcLif:name managed object property"
::= { cfprVnicFcLifEntry 5 }
cfprVnicFcLifNicDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcLif:nicDn managed object property"
::= { cfprVnicFcLifEntry 6 }
cfprVnicFcLifOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcLif:owner managed object property"
::= { cfprVnicFcLifEntry 7 }
cfprVnicFcLifSwitchId OBJECT-TYPE
SYNTAX CfprNetworkSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcLif:switchId managed object property"
::= { cfprVnicFcLifEntry 8 }
cfprVnicFcLifType OBJECT-TYPE
SYNTAX CfprVnicConnectionType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcLif:type managed object property"
::= { cfprVnicFcLifEntry 9 }
cfprVnicFcLifVnicDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcLif:vnicDn managed object property"
::= { cfprVnicFcLifEntry 10 }
cfprVnicFcNodeTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicFcNodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcNode managed object table"
::= { cfprVnicObjects 19 }
cfprVnicFcNodeEntry OBJECT-TYPE
SYNTAX CfprVnicFcNodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicFcNodeTable table."
INDEX { cfprVnicFcNodeInstanceId }
::= { cfprVnicFcNodeTable 1 }
CfprVnicFcNodeEntry ::= SEQUENCE {
cfprVnicFcNodeInstanceId CfprManagedObjectId,
cfprVnicFcNodeDn CfprManagedObjectDn,
cfprVnicFcNodeRn SnmpAdminString,
cfprVnicFcNodeAddrData Unsigned64,
cfprVnicFcNodeFltAggr Unsigned64,
cfprVnicFcNodeIdentPoolName SnmpAdminString,
cfprVnicFcNodeMaxDerivableWWPN Gauge32,
cfprVnicFcNodeOperIdentPoolName SnmpAdminString,
cfprVnicFcNodeOwner CfprVnicFcNodeOwner
}
cfprVnicFcNodeInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicFcNodeEntry 1 }
cfprVnicFcNodeDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcNode:dn managed object property"
::= { cfprVnicFcNodeEntry 2 }
cfprVnicFcNodeRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcNode:rn managed object property"
::= { cfprVnicFcNodeEntry 3 }
cfprVnicFcNodeAddrData OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcNode:addr managed object property"
::= { cfprVnicFcNodeEntry 4 }
cfprVnicFcNodeFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcNode:fltAggr managed object property"
::= { cfprVnicFcNodeEntry 5 }
cfprVnicFcNodeIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcNode:identPoolName managed
object property"
::= { cfprVnicFcNodeEntry 6 }
cfprVnicFcNodeMaxDerivableWWPN OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcNode:maxDerivableWWPN managed
object property"
::= { cfprVnicFcNodeEntry 7 }
cfprVnicFcNodeOperIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcNode:operIdentPoolName
managed object property"
::= { cfprVnicFcNodeEntry 8 }
cfprVnicFcNodeOwner OBJECT-TYPE
SYNTAX CfprVnicFcNodeOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcNode:owner managed object property"
::= { cfprVnicFcNodeEntry 9 }
cfprVnicFcOEIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicFcOEIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf managed object table"
::= { cfprVnicObjects 20 }
cfprVnicFcOEIfEntry OBJECT-TYPE
SYNTAX CfprVnicFcOEIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicFcOEIfTable table."
INDEX { cfprVnicFcOEIfInstanceId }
::= { cfprVnicFcOEIfTable 1 }
CfprVnicFcOEIfEntry ::= SEQUENCE {
cfprVnicFcOEIfInstanceId CfprManagedObjectId,
cfprVnicFcOEIfDn CfprManagedObjectDn,
cfprVnicFcOEIfRn SnmpAdminString,
cfprVnicFcOEIfConfigQualifier CfprVnicConfigIssues,
cfprVnicFcOEIfInitiator Unsigned64,
cfprVnicFcOEIfName SnmpAdminString,
cfprVnicFcOEIfOperState CfprVnicIfOperState,
cfprVnicFcOEIfOperVnetDn SnmpAdminString,
cfprVnicFcOEIfOperVnetName SnmpAdminString,
cfprVnicFcOEIfOwner CfprVnicConnectionOwner,
cfprVnicFcOEIfPubNwId Gauge32,
cfprVnicFcOEIfSharing CfprFabricVlanSharingType,
cfprVnicFcOEIfSwitchId CfprVnicL2IfSwitchId,
cfprVnicFcOEIfType CfprVnicAFcIfType,
cfprVnicFcOEIfVnet Gauge32
}
cfprVnicFcOEIfInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicFcOEIfEntry 1 }
cfprVnicFcOEIfDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:dn managed object property"
::= { cfprVnicFcOEIfEntry 2 }
cfprVnicFcOEIfRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:rn managed object property"
::= { cfprVnicFcOEIfEntry 3 }
cfprVnicFcOEIfConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:configQualifier managed
object property"
::= { cfprVnicFcOEIfEntry 4 }
cfprVnicFcOEIfInitiator OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:initiator managed object property"
::= { cfprVnicFcOEIfEntry 5 }
cfprVnicFcOEIfName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:name managed object property"
::= { cfprVnicFcOEIfEntry 6 }
cfprVnicFcOEIfOperState OBJECT-TYPE
SYNTAX CfprVnicIfOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:operState managed object property"
::= { cfprVnicFcOEIfEntry 7 }
cfprVnicFcOEIfOperVnetDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:operVnetDn managed object property"
::= { cfprVnicFcOEIfEntry 8 }
cfprVnicFcOEIfOperVnetName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:operVnetName managed object property"
::= { cfprVnicFcOEIfEntry 9 }
cfprVnicFcOEIfOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:owner managed object property"
::= { cfprVnicFcOEIfEntry 10 }
cfprVnicFcOEIfPubNwId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:pubNwId managed object property"
::= { cfprVnicFcOEIfEntry 11 }
cfprVnicFcOEIfSharing OBJECT-TYPE
SYNTAX CfprFabricVlanSharingType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:sharing managed object property"
::= { cfprVnicFcOEIfEntry 12 }
cfprVnicFcOEIfSwitchId OBJECT-TYPE
SYNTAX CfprVnicL2IfSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:switchId managed object property"
::= { cfprVnicFcOEIfEntry 13 }
cfprVnicFcOEIfType OBJECT-TYPE
SYNTAX CfprVnicAFcIfType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:type managed object property"
::= { cfprVnicFcOEIfEntry 14 }
cfprVnicFcOEIfVnet OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:FcOEIf:vnet managed object property"
::= { cfprVnicFcOEIfEntry 15 }
cfprVnicIPv4DhcpTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIPv4DhcpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dhcp managed object table"
::= { cfprVnicObjects 21 }
cfprVnicIPv4DhcpEntry OBJECT-TYPE
SYNTAX CfprVnicIPv4DhcpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIPv4DhcpTable table."
INDEX { cfprVnicIPv4DhcpInstanceId }
::= { cfprVnicIPv4DhcpTable 1 }
CfprVnicIPv4DhcpEntry ::= SEQUENCE {
cfprVnicIPv4DhcpInstanceId CfprManagedObjectId,
cfprVnicIPv4DhcpDn CfprManagedObjectDn,
cfprVnicIPv4DhcpRn SnmpAdminString,
cfprVnicIPv4DhcpAddr InetAddressIPv4,
cfprVnicIPv4DhcpDefGw InetAddressIPv4,
cfprVnicIPv4DhcpSubnet InetAddressIPv4
}
cfprVnicIPv4DhcpInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIPv4DhcpEntry 1 }
cfprVnicIPv4DhcpDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dhcp:dn managed object property"
::= { cfprVnicIPv4DhcpEntry 2 }
cfprVnicIPv4DhcpRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dhcp:rn managed object property"
::= { cfprVnicIPv4DhcpEntry 3 }
cfprVnicIPv4DhcpAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dhcp:addr managed object property"
::= { cfprVnicIPv4DhcpEntry 4 }
cfprVnicIPv4DhcpDefGw OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dhcp:defGw managed object property"
::= { cfprVnicIPv4DhcpEntry 5 }
cfprVnicIPv4DhcpSubnet OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dhcp:subnet managed object property"
::= { cfprVnicIPv4DhcpEntry 6 }
cfprVnicIPv4DnsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIPv4DnsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dns managed object table"
::= { cfprVnicObjects 22 }
cfprVnicIPv4DnsEntry OBJECT-TYPE
SYNTAX CfprVnicIPv4DnsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIPv4DnsTable table."
INDEX { cfprVnicIPv4DnsInstanceId }
::= { cfprVnicIPv4DnsTable 1 }
CfprVnicIPv4DnsEntry ::= SEQUENCE {
cfprVnicIPv4DnsInstanceId CfprManagedObjectId,
cfprVnicIPv4DnsDn CfprManagedObjectDn,
cfprVnicIPv4DnsRn SnmpAdminString,
cfprVnicIPv4DnsAddr InetAddressIPv4,
cfprVnicIPv4DnsDefGw InetAddressIPv4,
cfprVnicIPv4DnsPref CfprVnicIPv4DnsPref,
cfprVnicIPv4DnsSubnet InetAddressIPv4
}
cfprVnicIPv4DnsInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIPv4DnsEntry 1 }
cfprVnicIPv4DnsDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dns:dn managed object property"
::= { cfprVnicIPv4DnsEntry 2 }
cfprVnicIPv4DnsRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dns:rn managed object property"
::= { cfprVnicIPv4DnsEntry 3 }
cfprVnicIPv4DnsAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dns:addr managed object property"
::= { cfprVnicIPv4DnsEntry 4 }
cfprVnicIPv4DnsDefGw OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dns:defGw managed object property"
::= { cfprVnicIPv4DnsEntry 5 }
cfprVnicIPv4DnsPref OBJECT-TYPE
SYNTAX CfprVnicIPv4DnsPref
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dns:pref managed object property"
::= { cfprVnicIPv4DnsEntry 6 }
cfprVnicIPv4DnsSubnet OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4Dns:subnet managed object property"
::= { cfprVnicIPv4DnsEntry 7 }
cfprVnicIPv4IfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIPv4IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If managed object table"
::= { cfprVnicObjects 23 }
cfprVnicIPv4IfEntry OBJECT-TYPE
SYNTAX CfprVnicIPv4IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIPv4IfTable table."
INDEX { cfprVnicIPv4IfInstanceId }
::= { cfprVnicIPv4IfTable 1 }
CfprVnicIPv4IfEntry ::= SEQUENCE {
cfprVnicIPv4IfInstanceId CfprManagedObjectId,
cfprVnicIPv4IfDn CfprManagedObjectDn,
cfprVnicIPv4IfRn SnmpAdminString,
cfprVnicIPv4IfAddr InetAddressIPv4,
cfprVnicIPv4IfConfigQualifier CfprVnicConfigIssues,
cfprVnicIPv4IfName SnmpAdminString,
cfprVnicIPv4IfOperState CfprVnicIfOperState,
cfprVnicIPv4IfOperVnetDn SnmpAdminString,
cfprVnicIPv4IfOperVnetName SnmpAdminString,
cfprVnicIPv4IfOwner CfprVnicConnectionOwner,
cfprVnicIPv4IfPubNwId Gauge32,
cfprVnicIPv4IfSharing CfprFabricVlanSharingType,
cfprVnicIPv4IfSwitchId CfprNetworkSwitchId,
cfprVnicIPv4IfType CfprVnicConnectionType,
cfprVnicIPv4IfVnet Gauge32
}
cfprVnicIPv4IfInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIPv4IfEntry 1 }
cfprVnicIPv4IfDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:dn managed object property"
::= { cfprVnicIPv4IfEntry 2 }
cfprVnicIPv4IfRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:rn managed object property"
::= { cfprVnicIPv4IfEntry 3 }
cfprVnicIPv4IfAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:addr managed object property"
::= { cfprVnicIPv4IfEntry 4 }
cfprVnicIPv4IfConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:configQualifier managed
object property"
::= { cfprVnicIPv4IfEntry 5 }
cfprVnicIPv4IfName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:name managed object property"
::= { cfprVnicIPv4IfEntry 6 }
cfprVnicIPv4IfOperState OBJECT-TYPE
SYNTAX CfprVnicIfOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:operState managed object property"
::= { cfprVnicIPv4IfEntry 7 }
cfprVnicIPv4IfOperVnetDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:operVnetDn managed object property"
::= { cfprVnicIPv4IfEntry 8 }
cfprVnicIPv4IfOperVnetName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:operVnetName managed object property"
::= { cfprVnicIPv4IfEntry 9 }
cfprVnicIPv4IfOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:owner managed object property"
::= { cfprVnicIPv4IfEntry 10 }
cfprVnicIPv4IfPubNwId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:pubNwId managed object property"
::= { cfprVnicIPv4IfEntry 11 }
cfprVnicIPv4IfSharing OBJECT-TYPE
SYNTAX CfprFabricVlanSharingType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:sharing managed object property"
::= { cfprVnicIPv4IfEntry 12 }
cfprVnicIPv4IfSwitchId OBJECT-TYPE
SYNTAX CfprNetworkSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:switchId managed object property"
::= { cfprVnicIPv4IfEntry 13 }
cfprVnicIPv4IfType OBJECT-TYPE
SYNTAX CfprVnicConnectionType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:type managed object property"
::= { cfprVnicIPv4IfEntry 14 }
cfprVnicIPv4IfVnet OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4If:vnet managed object property"
::= { cfprVnicIPv4IfEntry 15 }
cfprVnicIPv4IscsiAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIPv4IscsiAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4IscsiAddr managed object table"
::= { cfprVnicObjects 24 }
cfprVnicIPv4IscsiAddrEntry OBJECT-TYPE
SYNTAX CfprVnicIPv4IscsiAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIPv4IscsiAddrTable table."
INDEX { cfprVnicIPv4IscsiAddrInstanceId }
::= { cfprVnicIPv4IscsiAddrTable 1 }
CfprVnicIPv4IscsiAddrEntry ::= SEQUENCE {
cfprVnicIPv4IscsiAddrInstanceId CfprManagedObjectId,
cfprVnicIPv4IscsiAddrDn CfprManagedObjectDn,
cfprVnicIPv4IscsiAddrRn SnmpAdminString,
cfprVnicIPv4IscsiAddrAddr InetAddressIPv4,
cfprVnicIPv4IscsiAddrDefGw InetAddressIPv4,
cfprVnicIPv4IscsiAddrPrimDns InetAddressIPv4,
cfprVnicIPv4IscsiAddrSecDns InetAddressIPv4,
cfprVnicIPv4IscsiAddrSubnet InetAddressIPv4
}
cfprVnicIPv4IscsiAddrInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIPv4IscsiAddrEntry 1 }
cfprVnicIPv4IscsiAddrDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4IscsiAddr:dn managed object property"
::= { cfprVnicIPv4IscsiAddrEntry 2 }
cfprVnicIPv4IscsiAddrRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4IscsiAddr:rn managed object property"
::= { cfprVnicIPv4IscsiAddrEntry 3 }
cfprVnicIPv4IscsiAddrAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4IscsiAddr:addr managed object property"
::= { cfprVnicIPv4IscsiAddrEntry 4 }
cfprVnicIPv4IscsiAddrDefGw OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4IscsiAddr:defGw managed object property"
::= { cfprVnicIPv4IscsiAddrEntry 5 }
cfprVnicIPv4IscsiAddrPrimDns OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4IscsiAddr:primDns managed
object property"
::= { cfprVnicIPv4IscsiAddrEntry 6 }
cfprVnicIPv4IscsiAddrSecDns OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4IscsiAddr:secDns managed
object property"
::= { cfprVnicIPv4IscsiAddrEntry 7 }
cfprVnicIPv4IscsiAddrSubnet OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4IscsiAddr:subnet managed
object property"
::= { cfprVnicIPv4IscsiAddrEntry 8 }
cfprVnicIPv4PooledIscsiAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIPv4PooledIscsiAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4PooledIscsiAddr managed object table"
::= { cfprVnicObjects 25 }
cfprVnicIPv4PooledIscsiAddrEntry OBJECT-TYPE
SYNTAX CfprVnicIPv4PooledIscsiAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIPv4PooledIscsiAddrTable table."
INDEX { cfprVnicIPv4PooledIscsiAddrInstanceId }
::= { cfprVnicIPv4PooledIscsiAddrTable 1 }
CfprVnicIPv4PooledIscsiAddrEntry ::= SEQUENCE {
cfprVnicIPv4PooledIscsiAddrInstanceId CfprManagedObjectId,
cfprVnicIPv4PooledIscsiAddrDn CfprManagedObjectDn,
cfprVnicIPv4PooledIscsiAddrRn SnmpAdminString,
cfprVnicIPv4PooledIscsiAddrAddr InetAddressIPv4,
cfprVnicIPv4PooledIscsiAddrDefGw InetAddressIPv4,
cfprVnicIPv4PooledIscsiAddrIdentPoolName SnmpAdminString,
cfprVnicIPv4PooledIscsiAddrOperIdentPoolName SnmpAdminString,
cfprVnicIPv4PooledIscsiAddrPrimDns InetAddressIPv4,
cfprVnicIPv4PooledIscsiAddrSecDns InetAddressIPv4,
cfprVnicIPv4PooledIscsiAddrSubnet InetAddressIPv4
}
cfprVnicIPv4PooledIscsiAddrInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIPv4PooledIscsiAddrEntry 1 }
cfprVnicIPv4PooledIscsiAddrDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4PooledIscsiAddr:dn managed
object property"
::= { cfprVnicIPv4PooledIscsiAddrEntry 2 }
cfprVnicIPv4PooledIscsiAddrRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4PooledIscsiAddr:rn managed
object property"
::= { cfprVnicIPv4PooledIscsiAddrEntry 3 }
cfprVnicIPv4PooledIscsiAddrAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4PooledIscsiAddr:addr
managed object property"
::= { cfprVnicIPv4PooledIscsiAddrEntry 4 }
cfprVnicIPv4PooledIscsiAddrDefGw OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4PooledIscsiAddr:defGw
managed object property"
::= { cfprVnicIPv4PooledIscsiAddrEntry 5 }
cfprVnicIPv4PooledIscsiAddrIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4PooledIscsiAddr:identPoolName
managed object property"
::= { cfprVnicIPv4PooledIscsiAddrEntry 6 }
cfprVnicIPv4PooledIscsiAddrOperIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4PooledIscsiAddr:operIdentPoolName
managed object property"
::= { cfprVnicIPv4PooledIscsiAddrEntry 7 }
cfprVnicIPv4PooledIscsiAddrPrimDns OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4PooledIscsiAddr:primDns
managed object property"
::= { cfprVnicIPv4PooledIscsiAddrEntry 8 }
cfprVnicIPv4PooledIscsiAddrSecDns OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4PooledIscsiAddr:secDns
managed object property"
::= { cfprVnicIPv4PooledIscsiAddrEntry 9 }
cfprVnicIPv4PooledIscsiAddrSubnet OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4PooledIscsiAddr:subnet
managed object property"
::= { cfprVnicIPv4PooledIscsiAddrEntry 10 }
cfprVnicIPv4StaticRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIPv4StaticRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4StaticRoute managed object table"
::= { cfprVnicObjects 26 }
cfprVnicIPv4StaticRouteEntry OBJECT-TYPE
SYNTAX CfprVnicIPv4StaticRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIPv4StaticRouteTable table."
INDEX { cfprVnicIPv4StaticRouteInstanceId }
::= { cfprVnicIPv4StaticRouteTable 1 }
CfprVnicIPv4StaticRouteEntry ::= SEQUENCE {
cfprVnicIPv4StaticRouteInstanceId CfprManagedObjectId,
cfprVnicIPv4StaticRouteDn CfprManagedObjectDn,
cfprVnicIPv4StaticRouteRn SnmpAdminString,
cfprVnicIPv4StaticRouteAddr InetAddressIPv4,
cfprVnicIPv4StaticRouteDefGw InetAddressIPv4,
cfprVnicIPv4StaticRouteGwAddr InetAddressIPv4,
cfprVnicIPv4StaticRouteGwSubnet InetAddressIPv4,
cfprVnicIPv4StaticRouteSubnet InetAddressIPv4
}
cfprVnicIPv4StaticRouteInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIPv4StaticRouteEntry 1 }
cfprVnicIPv4StaticRouteDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4StaticRoute:dn managed object property"
::= { cfprVnicIPv4StaticRouteEntry 2 }
cfprVnicIPv4StaticRouteRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4StaticRoute:rn managed object property"
::= { cfprVnicIPv4StaticRouteEntry 3 }
cfprVnicIPv4StaticRouteAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4StaticRoute:addr managed
object property"
::= { cfprVnicIPv4StaticRouteEntry 4 }
cfprVnicIPv4StaticRouteDefGw OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4StaticRoute:defGw managed
object property"
::= { cfprVnicIPv4StaticRouteEntry 5 }
cfprVnicIPv4StaticRouteGwAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4StaticRoute:gwAddr managed
object property"
::= { cfprVnicIPv4StaticRouteEntry 6 }
cfprVnicIPv4StaticRouteGwSubnet OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4StaticRoute:gwSubnet
managed object property"
::= { cfprVnicIPv4StaticRouteEntry 7 }
cfprVnicIPv4StaticRouteSubnet OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IPv4StaticRoute:subnet managed
object property"
::= { cfprVnicIPv4StaticRouteEntry 8 }
cfprVnicIScsiTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIScsiEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi managed object table"
::= { cfprVnicObjects 27 }
cfprVnicIScsiEntry OBJECT-TYPE
SYNTAX CfprVnicIScsiEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIScsiTable table."
INDEX { cfprVnicIScsiInstanceId }
::= { cfprVnicIScsiTable 1 }
CfprVnicIScsiEntry ::= SEQUENCE {
cfprVnicIScsiInstanceId CfprManagedObjectId,
cfprVnicIScsiDn CfprManagedObjectDn,
cfprVnicIScsiRn SnmpAdminString,
cfprVnicIScsiAdaptorProfileName SnmpAdminString,
cfprVnicIScsiAddr MacAddress,
cfprVnicIScsiAdminHostPort CfprFabricHostPortId,
cfprVnicIScsiAdminVcon SnmpAdminString,
cfprVnicIScsiAppRole CfprVnicAppRole,
cfprVnicIScsiAuthProfileName SnmpAdminString,
cfprVnicIScsiBootDev CfprVnicVnicBootDev,
cfprVnicIScsiConfigQualifier CfprVnicConfigIssues,
cfprVnicIScsiConfigState CfprLsConfigState,
cfprVnicIScsiEquipmentDn SnmpAdminString,
cfprVnicIScsiEthEpDn SnmpAdminString,
cfprVnicIScsiExtIPState CfprVnicExternalMgmtIPMode,
cfprVnicIScsiFltAggr Unsigned64,
cfprVnicIScsiIdentPoolName SnmpAdminString,
cfprVnicIScsiInitNameSuffix SnmpAdminString,
cfprVnicIScsiInitiatorName SnmpAdminString,
cfprVnicIScsiInstType CfprVnicInstantiation,
cfprVnicIScsiIqnIdentPoolName SnmpAdminString,
cfprVnicIScsiName SnmpAdminString,
cfprVnicIScsiNwTemplName SnmpAdminString,
cfprVnicIScsiOperAdaptorProfileName SnmpAdminString,
cfprVnicIScsiOperAuthProfileName SnmpAdminString,
cfprVnicIScsiOperHostPort CfprVnicVnicOperHostPort,
cfprVnicIScsiOperIdentPoolName SnmpAdminString,
cfprVnicIScsiOperIqnIdentPoolName SnmpAdminString,
cfprVnicIScsiOperOrder Gauge32,
cfprVnicIScsiOperSpeed Gauge32,
cfprVnicIScsiOperStatsPolicyName SnmpAdminString,
cfprVnicIScsiOperVcon SnmpAdminString,
cfprVnicIScsiOrder Gauge32,
cfprVnicIScsiOwner CfprVnicConnectionOwner,
cfprVnicIScsiPinToGroupName SnmpAdminString,
cfprVnicIScsiQosPolicyName SnmpAdminString,
cfprVnicIScsiStatsPolicyName SnmpAdminString,
cfprVnicIScsiSwitchId CfprNetworkSwitchId,
cfprVnicIScsiType CfprVnicConnectionType,
cfprVnicIScsiVnicDefType CfprVnicIScsiIfDefType,
cfprVnicIScsiVnicName SnmpAdminString
}
cfprVnicIScsiInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIScsiEntry 1 }
cfprVnicIScsiDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:dn managed object property"
::= { cfprVnicIScsiEntry 2 }
cfprVnicIScsiRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:rn managed object property"
::= { cfprVnicIScsiEntry 3 }
cfprVnicIScsiAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:adaptorProfileName
managed object property"
::= { cfprVnicIScsiEntry 4 }
cfprVnicIScsiAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:addr managed object property"
::= { cfprVnicIScsiEntry 5 }
cfprVnicIScsiAdminHostPort OBJECT-TYPE
SYNTAX CfprFabricHostPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:adminHostPort managed object property"
::= { cfprVnicIScsiEntry 6 }
cfprVnicIScsiAdminVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:adminVcon managed object property"
::= { cfprVnicIScsiEntry 7 }
cfprVnicIScsiAppRole OBJECT-TYPE
SYNTAX CfprVnicAppRole
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:appRole managed object property"
::= { cfprVnicIScsiEntry 8 }
cfprVnicIScsiAuthProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:authProfileName managed
object property"
::= { cfprVnicIScsiEntry 9 }
cfprVnicIScsiBootDev OBJECT-TYPE
SYNTAX CfprVnicVnicBootDev
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:bootDev managed object property"
::= { cfprVnicIScsiEntry 10 }
cfprVnicIScsiConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:configQualifier managed
object property"
::= { cfprVnicIScsiEntry 11 }
cfprVnicIScsiConfigState OBJECT-TYPE
SYNTAX CfprLsConfigState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:configState managed object property"
::= { cfprVnicIScsiEntry 12 }
cfprVnicIScsiEquipmentDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:equipmentDn managed object property"
::= { cfprVnicIScsiEntry 13 }
cfprVnicIScsiEthEpDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:ethEpDn managed object property"
::= { cfprVnicIScsiEntry 14 }
cfprVnicIScsiExtIPState OBJECT-TYPE
SYNTAX CfprVnicExternalMgmtIPMode
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:extIPState managed object property"
::= { cfprVnicIScsiEntry 15 }
cfprVnicIScsiFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:fltAggr managed object property"
::= { cfprVnicIScsiEntry 16 }
cfprVnicIScsiIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:identPoolName managed object property"
::= { cfprVnicIScsiEntry 17 }
cfprVnicIScsiInitNameSuffix OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:initNameSuffix managed
object property"
::= { cfprVnicIScsiEntry 18 }
cfprVnicIScsiInitiatorName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:initiatorName managed object property"
::= { cfprVnicIScsiEntry 19 }
cfprVnicIScsiInstType OBJECT-TYPE
SYNTAX CfprVnicInstantiation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:instType managed object property"
::= { cfprVnicIScsiEntry 20 }
cfprVnicIScsiIqnIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:iqnIdentPoolName managed
object property"
::= { cfprVnicIScsiEntry 21 }
cfprVnicIScsiName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:name managed object property"
::= { cfprVnicIScsiEntry 22 }
cfprVnicIScsiNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:nwTemplName managed object property"
::= { cfprVnicIScsiEntry 23 }
cfprVnicIScsiOperAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:operAdaptorProfileName
managed object property"
::= { cfprVnicIScsiEntry 24 }
cfprVnicIScsiOperAuthProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:operAuthProfileName
managed object property"
::= { cfprVnicIScsiEntry 25 }
cfprVnicIScsiOperHostPort OBJECT-TYPE
SYNTAX CfprVnicVnicOperHostPort
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:operHostPort managed object property"
::= { cfprVnicIScsiEntry 26 }
cfprVnicIScsiOperIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:operIdentPoolName managed
object property"
::= { cfprVnicIScsiEntry 27 }
cfprVnicIScsiOperIqnIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:operIqnIdentPoolName
managed object property"
::= { cfprVnicIScsiEntry 28 }
cfprVnicIScsiOperOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:operOrder managed object property"
::= { cfprVnicIScsiEntry 29 }
cfprVnicIScsiOperSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:operSpeed managed object property"
::= { cfprVnicIScsiEntry 30 }
cfprVnicIScsiOperStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:operStatsPolicyName
managed object property"
::= { cfprVnicIScsiEntry 31 }
cfprVnicIScsiOperVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:operVcon managed object property"
::= { cfprVnicIScsiEntry 32 }
cfprVnicIScsiOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:order managed object property"
::= { cfprVnicIScsiEntry 33 }
cfprVnicIScsiOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:owner managed object property"
::= { cfprVnicIScsiEntry 34 }
cfprVnicIScsiPinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:pinToGroupName managed
object property"
::= { cfprVnicIScsiEntry 35 }
cfprVnicIScsiQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:qosPolicyName managed object property"
::= { cfprVnicIScsiEntry 36 }
cfprVnicIScsiStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:statsPolicyName managed
object property"
::= { cfprVnicIScsiEntry 37 }
cfprVnicIScsiSwitchId OBJECT-TYPE
SYNTAX CfprNetworkSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:switchId managed object property"
::= { cfprVnicIScsiEntry 38 }
cfprVnicIScsiType OBJECT-TYPE
SYNTAX CfprVnicConnectionType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:type managed object property"
::= { cfprVnicIScsiEntry 39 }
cfprVnicIScsiVnicDefType OBJECT-TYPE
SYNTAX CfprVnicIScsiIfDefType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:vnicDefType managed object property"
::= { cfprVnicIScsiEntry 40 }
cfprVnicIScsiVnicName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsi:vnicName managed object property"
::= { cfprVnicIScsiEntry 41 }
cfprVnicIScsiAutoTargetIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIScsiAutoTargetIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiAutoTargetIf managed object table"
::= { cfprVnicObjects 28 }
cfprVnicIScsiAutoTargetIfEntry OBJECT-TYPE
SYNTAX CfprVnicIScsiAutoTargetIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIScsiAutoTargetIfTable table."
INDEX { cfprVnicIScsiAutoTargetIfInstanceId }
::= { cfprVnicIScsiAutoTargetIfTable 1 }
CfprVnicIScsiAutoTargetIfEntry ::= SEQUENCE {
cfprVnicIScsiAutoTargetIfInstanceId CfprManagedObjectId,
cfprVnicIScsiAutoTargetIfDn CfprManagedObjectDn,
cfprVnicIScsiAutoTargetIfRn SnmpAdminString,
cfprVnicIScsiAutoTargetIfDhcpVendorId SnmpAdminString
}
cfprVnicIScsiAutoTargetIfInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIScsiAutoTargetIfEntry 1 }
cfprVnicIScsiAutoTargetIfDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiAutoTargetIf:dn managed
object property"
::= { cfprVnicIScsiAutoTargetIfEntry 2 }
cfprVnicIScsiAutoTargetIfRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiAutoTargetIf:rn managed
object property"
::= { cfprVnicIScsiAutoTargetIfEntry 3 }
cfprVnicIScsiAutoTargetIfDhcpVendorId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiAutoTargetIf:dhcpVendorId
managed object property"
::= { cfprVnicIScsiAutoTargetIfEntry 4 }
cfprVnicIScsiBootParamsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIScsiBootParamsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootParams managed object table"
::= { cfprVnicObjects 29 }
cfprVnicIScsiBootParamsEntry OBJECT-TYPE
SYNTAX CfprVnicIScsiBootParamsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIScsiBootParamsTable table."
INDEX { cfprVnicIScsiBootParamsInstanceId }
::= { cfprVnicIScsiBootParamsTable 1 }
CfprVnicIScsiBootParamsEntry ::= SEQUENCE {
cfprVnicIScsiBootParamsInstanceId CfprManagedObjectId,
cfprVnicIScsiBootParamsDn CfprManagedObjectDn,
cfprVnicIScsiBootParamsRn SnmpAdminString,
cfprVnicIScsiBootParamsDescr SnmpAdminString,
cfprVnicIScsiBootParamsIntId SnmpAdminString,
cfprVnicIScsiBootParamsName SnmpAdminString,
cfprVnicIScsiBootParamsPolicyLevel Gauge32,
cfprVnicIScsiBootParamsPolicyOwner CfprPolicyPolicyOwner
}
cfprVnicIScsiBootParamsInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIScsiBootParamsEntry 1 }
cfprVnicIScsiBootParamsDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootParams:dn managed object property"
::= { cfprVnicIScsiBootParamsEntry 2 }
cfprVnicIScsiBootParamsRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootParams:rn managed object property"
::= { cfprVnicIScsiBootParamsEntry 3 }
cfprVnicIScsiBootParamsDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootParams:descr managed
object property"
::= { cfprVnicIScsiBootParamsEntry 4 }
cfprVnicIScsiBootParamsIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootParams:intId managed
object property"
::= { cfprVnicIScsiBootParamsEntry 5 }
cfprVnicIScsiBootParamsName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootParams:name managed
object property"
::= { cfprVnicIScsiBootParamsEntry 6 }
cfprVnicIScsiBootParamsPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootParams:policyLevel
managed object property"
::= { cfprVnicIScsiBootParamsEntry 7 }
cfprVnicIScsiBootParamsPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootParams:policyOwner
managed object property"
::= { cfprVnicIScsiBootParamsEntry 8 }
cfprVnicIScsiBootVnicTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIScsiBootVnicEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic managed object table"
::= { cfprVnicObjects 30 }
cfprVnicIScsiBootVnicEntry OBJECT-TYPE
SYNTAX CfprVnicIScsiBootVnicEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIScsiBootVnicTable table."
INDEX { cfprVnicIScsiBootVnicInstanceId }
::= { cfprVnicIScsiBootVnicTable 1 }
CfprVnicIScsiBootVnicEntry ::= SEQUENCE {
cfprVnicIScsiBootVnicInstanceId CfprManagedObjectId,
cfprVnicIScsiBootVnicDn CfprManagedObjectDn,
cfprVnicIScsiBootVnicRn SnmpAdminString,
cfprVnicIScsiBootVnicAuthProfileName SnmpAdminString,
cfprVnicIScsiBootVnicDescr SnmpAdminString,
cfprVnicIScsiBootVnicInitiatorName SnmpAdminString,
cfprVnicIScsiBootVnicIntId SnmpAdminString,
cfprVnicIScsiBootVnicIqnIdentPoolName SnmpAdminString,
cfprVnicIScsiBootVnicName SnmpAdminString,
cfprVnicIScsiBootVnicOperAuthProfileName SnmpAdminString,
cfprVnicIScsiBootVnicOperIqnIdentPoolName SnmpAdminString,
cfprVnicIScsiBootVnicPolicyLevel Gauge32,
cfprVnicIScsiBootVnicPolicyOwner CfprPolicyPolicyOwner
}
cfprVnicIScsiBootVnicInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIScsiBootVnicEntry 1 }
cfprVnicIScsiBootVnicDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:dn managed object property"
::= { cfprVnicIScsiBootVnicEntry 2 }
cfprVnicIScsiBootVnicRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:rn managed object property"
::= { cfprVnicIScsiBootVnicEntry 3 }
cfprVnicIScsiBootVnicAuthProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:authProfileName
managed object property"
::= { cfprVnicIScsiBootVnicEntry 4 }
cfprVnicIScsiBootVnicDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:descr managed object property"
::= { cfprVnicIScsiBootVnicEntry 5 }
cfprVnicIScsiBootVnicInitiatorName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:initiatorName
managed object property"
::= { cfprVnicIScsiBootVnicEntry 6 }
cfprVnicIScsiBootVnicIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:intId managed object property"
::= { cfprVnicIScsiBootVnicEntry 7 }
cfprVnicIScsiBootVnicIqnIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:iqnIdentPoolName
managed object property"
::= { cfprVnicIScsiBootVnicEntry 8 }
cfprVnicIScsiBootVnicName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:name managed object property"
::= { cfprVnicIScsiBootVnicEntry 9 }
cfprVnicIScsiBootVnicOperAuthProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:operAuthProfileName
managed object property"
::= { cfprVnicIScsiBootVnicEntry 10 }
cfprVnicIScsiBootVnicOperIqnIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:operIqnIdentPoolName
managed object property"
::= { cfprVnicIScsiBootVnicEntry 11 }
cfprVnicIScsiBootVnicPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:policyLevel
managed object property"
::= { cfprVnicIScsiBootVnicEntry 12 }
cfprVnicIScsiBootVnicPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiBootVnic:policyOwner
managed object property"
::= { cfprVnicIScsiBootVnicEntry 13 }
cfprVnicIScsiLCPTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIScsiLCPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP managed object table"
::= { cfprVnicObjects 31 }
cfprVnicIScsiLCPEntry OBJECT-TYPE
SYNTAX CfprVnicIScsiLCPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIScsiLCPTable table."
INDEX { cfprVnicIScsiLCPInstanceId }
::= { cfprVnicIScsiLCPTable 1 }
CfprVnicIScsiLCPEntry ::= SEQUENCE {
cfprVnicIScsiLCPInstanceId CfprManagedObjectId,
cfprVnicIScsiLCPDn CfprManagedObjectDn,
cfprVnicIScsiLCPRn SnmpAdminString,
cfprVnicIScsiLCPAdaptorProfileName SnmpAdminString,
cfprVnicIScsiLCPAddr MacAddress,
cfprVnicIScsiLCPAdminHostPort CfprFabricHostPortId,
cfprVnicIScsiLCPAdminVcon SnmpAdminString,
cfprVnicIScsiLCPAppRole CfprVnicAppRole,
cfprVnicIScsiLCPBootDev CfprVnicVnicBootDev,
cfprVnicIScsiLCPConfigQualifier CfprVnicConfigIssues,
cfprVnicIScsiLCPConfigState CfprLsConfigState,
cfprVnicIScsiLCPEquipmentDn SnmpAdminString,
cfprVnicIScsiLCPFltAggr Unsigned64,
cfprVnicIScsiLCPIdentPoolName SnmpAdminString,
cfprVnicIScsiLCPInstType CfprVnicInstantiation,
cfprVnicIScsiLCPName SnmpAdminString,
cfprVnicIScsiLCPNwTemplName SnmpAdminString,
cfprVnicIScsiLCPOperAdaptorProfileName SnmpAdminString,
cfprVnicIScsiLCPOperHostPort CfprVnicVnicOperHostPort,
cfprVnicIScsiLCPOperIdentPoolName SnmpAdminString,
cfprVnicIScsiLCPOperOrder Gauge32,
cfprVnicIScsiLCPOperSpeed Gauge32,
cfprVnicIScsiLCPOperStatsPolicyName SnmpAdminString,
cfprVnicIScsiLCPOperVcon SnmpAdminString,
cfprVnicIScsiLCPOrder Gauge32,
cfprVnicIScsiLCPOwner CfprVnicConnectionOwner,
cfprVnicIScsiLCPPinToGroupName SnmpAdminString,
cfprVnicIScsiLCPQosPolicyName SnmpAdminString,
cfprVnicIScsiLCPStatsPolicyName SnmpAdminString,
cfprVnicIScsiLCPSwitchId CfprNetworkSwitchId,
cfprVnicIScsiLCPType CfprVnicConnectionType,
cfprVnicIScsiLCPVnicName SnmpAdminString
}
cfprVnicIScsiLCPInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIScsiLCPEntry 1 }
cfprVnicIScsiLCPDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:dn managed object property"
::= { cfprVnicIScsiLCPEntry 2 }
cfprVnicIScsiLCPRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:rn managed object property"
::= { cfprVnicIScsiLCPEntry 3 }
cfprVnicIScsiLCPAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:adaptorProfileName
managed object property"
::= { cfprVnicIScsiLCPEntry 4 }
cfprVnicIScsiLCPAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:addr managed object property"
::= { cfprVnicIScsiLCPEntry 5 }
cfprVnicIScsiLCPAdminHostPort OBJECT-TYPE
SYNTAX CfprFabricHostPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:adminHostPort managed
object property"
::= { cfprVnicIScsiLCPEntry 6 }
cfprVnicIScsiLCPAdminVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:adminVcon managed object property"
::= { cfprVnicIScsiLCPEntry 7 }
cfprVnicIScsiLCPAppRole OBJECT-TYPE
SYNTAX CfprVnicAppRole
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:appRole managed object property"
::= { cfprVnicIScsiLCPEntry 8 }
cfprVnicIScsiLCPBootDev OBJECT-TYPE
SYNTAX CfprVnicVnicBootDev
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:bootDev managed object property"
::= { cfprVnicIScsiLCPEntry 9 }
cfprVnicIScsiLCPConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:configQualifier
managed object property"
::= { cfprVnicIScsiLCPEntry 10 }
cfprVnicIScsiLCPConfigState OBJECT-TYPE
SYNTAX CfprLsConfigState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:configState managed
object property"
::= { cfprVnicIScsiLCPEntry 11 }
cfprVnicIScsiLCPEquipmentDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:equipmentDn managed
object property"
::= { cfprVnicIScsiLCPEntry 12 }
cfprVnicIScsiLCPFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:fltAggr managed object property"
::= { cfprVnicIScsiLCPEntry 13 }
cfprVnicIScsiLCPIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:identPoolName managed
object property"
::= { cfprVnicIScsiLCPEntry 14 }
cfprVnicIScsiLCPInstType OBJECT-TYPE
SYNTAX CfprVnicInstantiation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:instType managed object property"
::= { cfprVnicIScsiLCPEntry 15 }
cfprVnicIScsiLCPName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:name managed object property"
::= { cfprVnicIScsiLCPEntry 16 }
cfprVnicIScsiLCPNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:nwTemplName managed
object property"
::= { cfprVnicIScsiLCPEntry 17 }
cfprVnicIScsiLCPOperAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:operAdaptorProfileName
managed object property"
::= { cfprVnicIScsiLCPEntry 18 }
cfprVnicIScsiLCPOperHostPort OBJECT-TYPE
SYNTAX CfprVnicVnicOperHostPort
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:operHostPort managed
object property"
::= { cfprVnicIScsiLCPEntry 19 }
cfprVnicIScsiLCPOperIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:operIdentPoolName
managed object property"
::= { cfprVnicIScsiLCPEntry 20 }
cfprVnicIScsiLCPOperOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:operOrder managed object property"
::= { cfprVnicIScsiLCPEntry 21 }
cfprVnicIScsiLCPOperSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:operSpeed managed object property"
::= { cfprVnicIScsiLCPEntry 22 }
cfprVnicIScsiLCPOperStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:operStatsPolicyName
managed object property"
::= { cfprVnicIScsiLCPEntry 23 }
cfprVnicIScsiLCPOperVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:operVcon managed object property"
::= { cfprVnicIScsiLCPEntry 24 }
cfprVnicIScsiLCPOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:order managed object property"
::= { cfprVnicIScsiLCPEntry 25 }
cfprVnicIScsiLCPOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:owner managed object property"
::= { cfprVnicIScsiLCPEntry 26 }
cfprVnicIScsiLCPPinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:pinToGroupName managed
object property"
::= { cfprVnicIScsiLCPEntry 27 }
cfprVnicIScsiLCPQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:qosPolicyName managed
object property"
::= { cfprVnicIScsiLCPEntry 28 }
cfprVnicIScsiLCPStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:statsPolicyName
managed object property"
::= { cfprVnicIScsiLCPEntry 29 }
cfprVnicIScsiLCPSwitchId OBJECT-TYPE
SYNTAX CfprNetworkSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:switchId managed object property"
::= { cfprVnicIScsiLCPEntry 30 }
cfprVnicIScsiLCPType OBJECT-TYPE
SYNTAX CfprVnicConnectionType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:type managed object property"
::= { cfprVnicIScsiLCPEntry 31 }
cfprVnicIScsiLCPVnicName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiLCP:vnicName managed object property"
::= { cfprVnicIScsiLCPEntry 32 }
cfprVnicIScsiNodeTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIScsiNodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiNode managed object table"
::= { cfprVnicObjects 32 }
cfprVnicIScsiNodeEntry OBJECT-TYPE
SYNTAX CfprVnicIScsiNodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIScsiNodeTable table."
INDEX { cfprVnicIScsiNodeInstanceId }
::= { cfprVnicIScsiNodeTable 1 }
CfprVnicIScsiNodeEntry ::= SEQUENCE {
cfprVnicIScsiNodeInstanceId CfprManagedObjectId,
cfprVnicIScsiNodeDn CfprManagedObjectDn,
cfprVnicIScsiNodeRn SnmpAdminString,
cfprVnicIScsiNodeFltAggr Unsigned64,
cfprVnicIScsiNodeInitNameSuffix SnmpAdminString,
cfprVnicIScsiNodeInitiatorName SnmpAdminString,
cfprVnicIScsiNodeIqnIdentPoolName SnmpAdminString,
cfprVnicIScsiNodeOperIqnIdentPoolName SnmpAdminString,
cfprVnicIScsiNodeOwner CfprVnicIScsiNodeOwner
}
cfprVnicIScsiNodeInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIScsiNodeEntry 1 }
cfprVnicIScsiNodeDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiNode:dn managed object property"
::= { cfprVnicIScsiNodeEntry 2 }
cfprVnicIScsiNodeRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiNode:rn managed object property"
::= { cfprVnicIScsiNodeEntry 3 }
cfprVnicIScsiNodeFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiNode:fltAggr managed object property"
::= { cfprVnicIScsiNodeEntry 4 }
cfprVnicIScsiNodeInitNameSuffix OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiNode:initNameSuffix
managed object property"
::= { cfprVnicIScsiNodeEntry 5 }
cfprVnicIScsiNodeInitiatorName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiNode:initiatorName managed
object property"
::= { cfprVnicIScsiNodeEntry 6 }
cfprVnicIScsiNodeIqnIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiNode:iqnIdentPoolName
managed object property"
::= { cfprVnicIScsiNodeEntry 7 }
cfprVnicIScsiNodeOperIqnIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiNode:operIqnIdentPoolName
managed object property"
::= { cfprVnicIScsiNodeEntry 8 }
cfprVnicIScsiNodeOwner OBJECT-TYPE
SYNTAX CfprVnicIScsiNodeOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiNode:owner managed object property"
::= { cfprVnicIScsiNodeEntry 9 }
cfprVnicIScsiStaticTargetIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIScsiStaticTargetIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiStaticTargetIf managed object table"
::= { cfprVnicObjects 33 }
cfprVnicIScsiStaticTargetIfEntry OBJECT-TYPE
SYNTAX CfprVnicIScsiStaticTargetIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIScsiStaticTargetIfTable table."
INDEX { cfprVnicIScsiStaticTargetIfInstanceId }
::= { cfprVnicIScsiStaticTargetIfTable 1 }
CfprVnicIScsiStaticTargetIfEntry ::= SEQUENCE {
cfprVnicIScsiStaticTargetIfInstanceId CfprManagedObjectId,
cfprVnicIScsiStaticTargetIfDn CfprManagedObjectDn,
cfprVnicIScsiStaticTargetIfRn SnmpAdminString,
cfprVnicIScsiStaticTargetIfAuthProfileName SnmpAdminString,
cfprVnicIScsiStaticTargetIfIpAddress InetAddressIPv4,
cfprVnicIScsiStaticTargetIfName SnmpAdminString,
cfprVnicIScsiStaticTargetIfOperAuthProfileName SnmpAdminString,
cfprVnicIScsiStaticTargetIfPort Gauge32,
cfprVnicIScsiStaticTargetIfPriority Gauge32
}
cfprVnicIScsiStaticTargetIfInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIScsiStaticTargetIfEntry 1 }
cfprVnicIScsiStaticTargetIfDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiStaticTargetIf:dn managed
object property"
::= { cfprVnicIScsiStaticTargetIfEntry 2 }
cfprVnicIScsiStaticTargetIfRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiStaticTargetIf:rn managed
object property"
::= { cfprVnicIScsiStaticTargetIfEntry 3 }
cfprVnicIScsiStaticTargetIfAuthProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiStaticTargetIf:authProfileName
managed object property"
::= { cfprVnicIScsiStaticTargetIfEntry 4 }
cfprVnicIScsiStaticTargetIfIpAddress OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiStaticTargetIf:ipAddress
managed object property"
::= { cfprVnicIScsiStaticTargetIfEntry 5 }
cfprVnicIScsiStaticTargetIfName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiStaticTargetIf:name
managed object property"
::= { cfprVnicIScsiStaticTargetIfEntry 6 }
cfprVnicIScsiStaticTargetIfOperAuthProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiStaticTargetIf:operAuthProfileName
managed object property"
::= { cfprVnicIScsiStaticTargetIfEntry 7 }
cfprVnicIScsiStaticTargetIfPort OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiStaticTargetIf:port
managed object property"
::= { cfprVnicIScsiStaticTargetIfEntry 8 }
cfprVnicIScsiStaticTargetIfPriority OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IScsiStaticTargetIf:priority
managed object property"
::= { cfprVnicIScsiStaticTargetIfEntry 9 }
cfprVnicInternalProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicInternalProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:InternalProfile managed object table"
::= { cfprVnicObjects 34 }
cfprVnicInternalProfileEntry OBJECT-TYPE
SYNTAX CfprVnicInternalProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicInternalProfileTable table."
INDEX { cfprVnicInternalProfileInstanceId }
::= { cfprVnicInternalProfileTable 1 }
CfprVnicInternalProfileEntry ::= SEQUENCE {
cfprVnicInternalProfileInstanceId CfprManagedObjectId,
cfprVnicInternalProfileDn CfprManagedObjectDn,
cfprVnicInternalProfileRn SnmpAdminString,
cfprVnicInternalProfileDescr SnmpAdminString,
cfprVnicInternalProfileIntId SnmpAdminString,
cfprVnicInternalProfileMaxPorts Gauge32,
cfprVnicInternalProfileName SnmpAdminString,
cfprVnicInternalProfilePolicyLevel Gauge32,
cfprVnicInternalProfilePolicyOwner CfprPolicyPolicyOwner
}
cfprVnicInternalProfileInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicInternalProfileEntry 1 }
cfprVnicInternalProfileDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:InternalProfile:dn managed object property"
::= { cfprVnicInternalProfileEntry 2 }
cfprVnicInternalProfileRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:InternalProfile:rn managed object property"
::= { cfprVnicInternalProfileEntry 3 }
cfprVnicInternalProfileDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:InternalProfile:descr managed
object property"
::= { cfprVnicInternalProfileEntry 4 }
cfprVnicInternalProfileIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:InternalProfile:intId managed
object property"
::= { cfprVnicInternalProfileEntry 5 }
cfprVnicInternalProfileMaxPorts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:InternalProfile:maxPorts
managed object property"
::= { cfprVnicInternalProfileEntry 6 }
cfprVnicInternalProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:InternalProfile:name managed
object property"
::= { cfprVnicInternalProfileEntry 7 }
cfprVnicInternalProfilePolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:InternalProfile:policyLevel
managed object property"
::= { cfprVnicInternalProfileEntry 8 }
cfprVnicInternalProfilePolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:InternalProfile:policyOwner
managed object property"
::= { cfprVnicInternalProfileEntry 9 }
cfprVnicIpV4HistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIpV4HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4History managed object table"
::= { cfprVnicObjects 35 }
cfprVnicIpV4HistoryEntry OBJECT-TYPE
SYNTAX CfprVnicIpV4HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIpV4HistoryTable table."
INDEX { cfprVnicIpV4HistoryInstanceId }
::= { cfprVnicIpV4HistoryTable 1 }
CfprVnicIpV4HistoryEntry ::= SEQUENCE {
cfprVnicIpV4HistoryInstanceId CfprManagedObjectId,
cfprVnicIpV4HistoryDn CfprManagedObjectDn,
cfprVnicIpV4HistoryRn SnmpAdminString,
cfprVnicIpV4HistoryOldIpV4Addr InetAddressIPv4
}
cfprVnicIpV4HistoryInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIpV4HistoryEntry 1 }
cfprVnicIpV4HistoryDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4History:dn managed object property"
::= { cfprVnicIpV4HistoryEntry 2 }
cfprVnicIpV4HistoryRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4History:rn managed object property"
::= { cfprVnicIpV4HistoryEntry 3 }
cfprVnicIpV4HistoryOldIpV4Addr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4History:oldIpV4Addr managed
object property"
::= { cfprVnicIpV4HistoryEntry 4 }
cfprVnicIpV4MgmtPooledAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIpV4MgmtPooledAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4MgmtPooledAddr managed object table"
::= { cfprVnicObjects 36 }
cfprVnicIpV4MgmtPooledAddrEntry OBJECT-TYPE
SYNTAX CfprVnicIpV4MgmtPooledAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIpV4MgmtPooledAddrTable table."
INDEX { cfprVnicIpV4MgmtPooledAddrInstanceId }
::= { cfprVnicIpV4MgmtPooledAddrTable 1 }
CfprVnicIpV4MgmtPooledAddrEntry ::= SEQUENCE {
cfprVnicIpV4MgmtPooledAddrInstanceId CfprManagedObjectId,
cfprVnicIpV4MgmtPooledAddrDn CfprManagedObjectDn,
cfprVnicIpV4MgmtPooledAddrRn SnmpAdminString,
cfprVnicIpV4MgmtPooledAddrAddr InetAddressIPv4,
cfprVnicIpV4MgmtPooledAddrDefGw InetAddressIPv4,
cfprVnicIpV4MgmtPooledAddrName SnmpAdminString,
cfprVnicIpV4MgmtPooledAddrOperName SnmpAdminString,
cfprVnicIpV4MgmtPooledAddrPrimDns InetAddressIPv4,
cfprVnicIpV4MgmtPooledAddrSecDns InetAddressIPv4,
cfprVnicIpV4MgmtPooledAddrSubnet InetAddressIPv4
}
cfprVnicIpV4MgmtPooledAddrInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIpV4MgmtPooledAddrEntry 1 }
cfprVnicIpV4MgmtPooledAddrDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4MgmtPooledAddr:dn managed
object property"
::= { cfprVnicIpV4MgmtPooledAddrEntry 2 }
cfprVnicIpV4MgmtPooledAddrRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4MgmtPooledAddr:rn managed
object property"
::= { cfprVnicIpV4MgmtPooledAddrEntry 3 }
cfprVnicIpV4MgmtPooledAddrAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4MgmtPooledAddr:addr managed
object property"
::= { cfprVnicIpV4MgmtPooledAddrEntry 4 }
cfprVnicIpV4MgmtPooledAddrDefGw OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4MgmtPooledAddr:defGw
managed object property"
::= { cfprVnicIpV4MgmtPooledAddrEntry 5 }
cfprVnicIpV4MgmtPooledAddrName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4MgmtPooledAddr:name managed
object property"
::= { cfprVnicIpV4MgmtPooledAddrEntry 6 }
cfprVnicIpV4MgmtPooledAddrOperName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4MgmtPooledAddr:operName
managed object property"
::= { cfprVnicIpV4MgmtPooledAddrEntry 7 }
cfprVnicIpV4MgmtPooledAddrPrimDns OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4MgmtPooledAddr:primDns
managed object property"
::= { cfprVnicIpV4MgmtPooledAddrEntry 8 }
cfprVnicIpV4MgmtPooledAddrSecDns OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4MgmtPooledAddr:secDns
managed object property"
::= { cfprVnicIpV4MgmtPooledAddrEntry 9 }
cfprVnicIpV4MgmtPooledAddrSubnet OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4MgmtPooledAddr:subnet
managed object property"
::= { cfprVnicIpV4MgmtPooledAddrEntry 10 }
cfprVnicIpV4PooledAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIpV4PooledAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4PooledAddr managed object table"
::= { cfprVnicObjects 37 }
cfprVnicIpV4PooledAddrEntry OBJECT-TYPE
SYNTAX CfprVnicIpV4PooledAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIpV4PooledAddrTable table."
INDEX { cfprVnicIpV4PooledAddrInstanceId }
::= { cfprVnicIpV4PooledAddrTable 1 }
CfprVnicIpV4PooledAddrEntry ::= SEQUENCE {
cfprVnicIpV4PooledAddrInstanceId CfprManagedObjectId,
cfprVnicIpV4PooledAddrDn CfprManagedObjectDn,
cfprVnicIpV4PooledAddrRn SnmpAdminString,
cfprVnicIpV4PooledAddrAddr InetAddressIPv4,
cfprVnicIpV4PooledAddrDefGw InetAddressIPv4,
cfprVnicIpV4PooledAddrName SnmpAdminString,
cfprVnicIpV4PooledAddrOperName SnmpAdminString,
cfprVnicIpV4PooledAddrPrimDns InetAddressIPv4,
cfprVnicIpV4PooledAddrSecDns InetAddressIPv4,
cfprVnicIpV4PooledAddrSubnet InetAddressIPv4
}
cfprVnicIpV4PooledAddrInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIpV4PooledAddrEntry 1 }
cfprVnicIpV4PooledAddrDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4PooledAddr:dn managed object property"
::= { cfprVnicIpV4PooledAddrEntry 2 }
cfprVnicIpV4PooledAddrRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4PooledAddr:rn managed object property"
::= { cfprVnicIpV4PooledAddrEntry 3 }
cfprVnicIpV4PooledAddrAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4PooledAddr:addr managed object property"
::= { cfprVnicIpV4PooledAddrEntry 4 }
cfprVnicIpV4PooledAddrDefGw OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4PooledAddr:defGw managed
object property"
::= { cfprVnicIpV4PooledAddrEntry 5 }
cfprVnicIpV4PooledAddrName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4PooledAddr:name managed object property"
::= { cfprVnicIpV4PooledAddrEntry 6 }
cfprVnicIpV4PooledAddrOperName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4PooledAddr:operName managed
object property"
::= { cfprVnicIpV4PooledAddrEntry 7 }
cfprVnicIpV4PooledAddrPrimDns OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4PooledAddr:primDns managed
object property"
::= { cfprVnicIpV4PooledAddrEntry 8 }
cfprVnicIpV4PooledAddrSecDns OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4PooledAddr:secDns managed
object property"
::= { cfprVnicIpV4PooledAddrEntry 9 }
cfprVnicIpV4PooledAddrSubnet OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4PooledAddr:subnet managed
object property"
::= { cfprVnicIpV4PooledAddrEntry 10 }
cfprVnicIpV4ProfDerivedAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIpV4ProfDerivedAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4ProfDerivedAddr managed object table"
::= { cfprVnicObjects 38 }
cfprVnicIpV4ProfDerivedAddrEntry OBJECT-TYPE
SYNTAX CfprVnicIpV4ProfDerivedAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIpV4ProfDerivedAddrTable table."
INDEX { cfprVnicIpV4ProfDerivedAddrInstanceId }
::= { cfprVnicIpV4ProfDerivedAddrTable 1 }
CfprVnicIpV4ProfDerivedAddrEntry ::= SEQUENCE {
cfprVnicIpV4ProfDerivedAddrInstanceId CfprManagedObjectId,
cfprVnicIpV4ProfDerivedAddrDn CfprManagedObjectDn,
cfprVnicIpV4ProfDerivedAddrRn SnmpAdminString,
cfprVnicIpV4ProfDerivedAddrAddr InetAddressIPv4,
cfprVnicIpV4ProfDerivedAddrDefGw InetAddressIPv4,
cfprVnicIpV4ProfDerivedAddrSubnet InetAddressIPv4
}
cfprVnicIpV4ProfDerivedAddrInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIpV4ProfDerivedAddrEntry 1 }
cfprVnicIpV4ProfDerivedAddrDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4ProfDerivedAddr:dn managed
object property"
::= { cfprVnicIpV4ProfDerivedAddrEntry 2 }
cfprVnicIpV4ProfDerivedAddrRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4ProfDerivedAddr:rn managed
object property"
::= { cfprVnicIpV4ProfDerivedAddrEntry 3 }
cfprVnicIpV4ProfDerivedAddrAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4ProfDerivedAddr:addr
managed object property"
::= { cfprVnicIpV4ProfDerivedAddrEntry 4 }
cfprVnicIpV4ProfDerivedAddrDefGw OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4ProfDerivedAddr:defGw
managed object property"
::= { cfprVnicIpV4ProfDerivedAddrEntry 5 }
cfprVnicIpV4ProfDerivedAddrSubnet OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4ProfDerivedAddr:subnet
managed object property"
::= { cfprVnicIpV4ProfDerivedAddrEntry 6 }
cfprVnicIpV4StaticAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIpV4StaticAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4StaticAddr managed object table"
::= { cfprVnicObjects 39 }
cfprVnicIpV4StaticAddrEntry OBJECT-TYPE
SYNTAX CfprVnicIpV4StaticAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIpV4StaticAddrTable table."
INDEX { cfprVnicIpV4StaticAddrInstanceId }
::= { cfprVnicIpV4StaticAddrTable 1 }
CfprVnicIpV4StaticAddrEntry ::= SEQUENCE {
cfprVnicIpV4StaticAddrInstanceId CfprManagedObjectId,
cfprVnicIpV4StaticAddrDn CfprManagedObjectDn,
cfprVnicIpV4StaticAddrRn SnmpAdminString,
cfprVnicIpV4StaticAddrAddr InetAddressIPv4,
cfprVnicIpV4StaticAddrDefGw InetAddressIPv4,
cfprVnicIpV4StaticAddrPrimDns InetAddressIPv4,
cfprVnicIpV4StaticAddrSecDns InetAddressIPv4,
cfprVnicIpV4StaticAddrSubnet InetAddressIPv4
}
cfprVnicIpV4StaticAddrInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIpV4StaticAddrEntry 1 }
cfprVnicIpV4StaticAddrDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4StaticAddr:dn managed object property"
::= { cfprVnicIpV4StaticAddrEntry 2 }
cfprVnicIpV4StaticAddrRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4StaticAddr:rn managed object property"
::= { cfprVnicIpV4StaticAddrEntry 3 }
cfprVnicIpV4StaticAddrAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4StaticAddr:addr managed object property"
::= { cfprVnicIpV4StaticAddrEntry 4 }
cfprVnicIpV4StaticAddrDefGw OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4StaticAddr:defGw managed
object property"
::= { cfprVnicIpV4StaticAddrEntry 5 }
cfprVnicIpV4StaticAddrPrimDns OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4StaticAddr:primDns managed
object property"
::= { cfprVnicIpV4StaticAddrEntry 6 }
cfprVnicIpV4StaticAddrSecDns OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4StaticAddr:secDns managed
object property"
::= { cfprVnicIpV4StaticAddrEntry 7 }
cfprVnicIpV4StaticAddrSubnet OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV4StaticAddr:subnet managed
object property"
::= { cfprVnicIpV4StaticAddrEntry 8 }
cfprVnicIpV6HistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIpV6HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6History managed object table"
::= { cfprVnicObjects 40 }
cfprVnicIpV6HistoryEntry OBJECT-TYPE
SYNTAX CfprVnicIpV6HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIpV6HistoryTable table."
INDEX { cfprVnicIpV6HistoryInstanceId }
::= { cfprVnicIpV6HistoryTable 1 }
CfprVnicIpV6HistoryEntry ::= SEQUENCE {
cfprVnicIpV6HistoryInstanceId CfprManagedObjectId,
cfprVnicIpV6HistoryDn CfprManagedObjectDn,
cfprVnicIpV6HistoryRn SnmpAdminString,
cfprVnicIpV6HistoryOldIpV6Addr InetAddressIPv6
}
cfprVnicIpV6HistoryInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIpV6HistoryEntry 1 }
cfprVnicIpV6HistoryDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6History:dn managed object property"
::= { cfprVnicIpV6HistoryEntry 2 }
cfprVnicIpV6HistoryRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6History:rn managed object property"
::= { cfprVnicIpV6HistoryEntry 3 }
cfprVnicIpV6HistoryOldIpV6Addr OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6History:oldIpV6Addr managed
object property"
::= { cfprVnicIpV6HistoryEntry 4 }
cfprVnicIpV6MgmtPooledAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIpV6MgmtPooledAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6MgmtPooledAddr managed object table"
::= { cfprVnicObjects 41 }
cfprVnicIpV6MgmtPooledAddrEntry OBJECT-TYPE
SYNTAX CfprVnicIpV6MgmtPooledAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIpV6MgmtPooledAddrTable table."
INDEX { cfprVnicIpV6MgmtPooledAddrInstanceId }
::= { cfprVnicIpV6MgmtPooledAddrTable 1 }
CfprVnicIpV6MgmtPooledAddrEntry ::= SEQUENCE {
cfprVnicIpV6MgmtPooledAddrInstanceId CfprManagedObjectId,
cfprVnicIpV6MgmtPooledAddrDn CfprManagedObjectDn,
cfprVnicIpV6MgmtPooledAddrRn SnmpAdminString,
cfprVnicIpV6MgmtPooledAddrAddr InetAddressIPv6,
cfprVnicIpV6MgmtPooledAddrDefGw InetAddressIPv6,
cfprVnicIpV6MgmtPooledAddrName SnmpAdminString,
cfprVnicIpV6MgmtPooledAddrOperName SnmpAdminString,
cfprVnicIpV6MgmtPooledAddrPrefix Gauge32,
cfprVnicIpV6MgmtPooledAddrPrimDns InetAddressIPv6,
cfprVnicIpV6MgmtPooledAddrSecDns InetAddressIPv6
}
cfprVnicIpV6MgmtPooledAddrInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIpV6MgmtPooledAddrEntry 1 }
cfprVnicIpV6MgmtPooledAddrDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6MgmtPooledAddr:dn managed
object property"
::= { cfprVnicIpV6MgmtPooledAddrEntry 2 }
cfprVnicIpV6MgmtPooledAddrRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6MgmtPooledAddr:rn managed
object property"
::= { cfprVnicIpV6MgmtPooledAddrEntry 3 }
cfprVnicIpV6MgmtPooledAddrAddr OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6MgmtPooledAddr:addr managed
object property"
::= { cfprVnicIpV6MgmtPooledAddrEntry 4 }
cfprVnicIpV6MgmtPooledAddrDefGw OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6MgmtPooledAddr:defGw
managed object property"
::= { cfprVnicIpV6MgmtPooledAddrEntry 5 }
cfprVnicIpV6MgmtPooledAddrName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6MgmtPooledAddr:name managed
object property"
::= { cfprVnicIpV6MgmtPooledAddrEntry 6 }
cfprVnicIpV6MgmtPooledAddrOperName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6MgmtPooledAddr:operName
managed object property"
::= { cfprVnicIpV6MgmtPooledAddrEntry 7 }
cfprVnicIpV6MgmtPooledAddrPrefix OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6MgmtPooledAddr:prefix
managed object property"
::= { cfprVnicIpV6MgmtPooledAddrEntry 8 }
cfprVnicIpV6MgmtPooledAddrPrimDns OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6MgmtPooledAddr:primDns
managed object property"
::= { cfprVnicIpV6MgmtPooledAddrEntry 9 }
cfprVnicIpV6MgmtPooledAddrSecDns OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6MgmtPooledAddr:secDns
managed object property"
::= { cfprVnicIpV6MgmtPooledAddrEntry 10 }
cfprVnicIpV6StaticAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIpV6StaticAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6StaticAddr managed object table"
::= { cfprVnicObjects 42 }
cfprVnicIpV6StaticAddrEntry OBJECT-TYPE
SYNTAX CfprVnicIpV6StaticAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIpV6StaticAddrTable table."
INDEX { cfprVnicIpV6StaticAddrInstanceId }
::= { cfprVnicIpV6StaticAddrTable 1 }
CfprVnicIpV6StaticAddrEntry ::= SEQUENCE {
cfprVnicIpV6StaticAddrInstanceId CfprManagedObjectId,
cfprVnicIpV6StaticAddrDn CfprManagedObjectDn,
cfprVnicIpV6StaticAddrRn SnmpAdminString,
cfprVnicIpV6StaticAddrAddr InetAddressIPv6,
cfprVnicIpV6StaticAddrDefGw InetAddressIPv6,
cfprVnicIpV6StaticAddrPrefix Gauge32,
cfprVnicIpV6StaticAddrPrimDns InetAddressIPv6,
cfprVnicIpV6StaticAddrSecDns InetAddressIPv6
}
cfprVnicIpV6StaticAddrInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIpV6StaticAddrEntry 1 }
cfprVnicIpV6StaticAddrDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6StaticAddr:dn managed object property"
::= { cfprVnicIpV6StaticAddrEntry 2 }
cfprVnicIpV6StaticAddrRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6StaticAddr:rn managed object property"
::= { cfprVnicIpV6StaticAddrEntry 3 }
cfprVnicIpV6StaticAddrAddr OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6StaticAddr:addr managed object property"
::= { cfprVnicIpV6StaticAddrEntry 4 }
cfprVnicIpV6StaticAddrDefGw OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6StaticAddr:defGw managed
object property"
::= { cfprVnicIpV6StaticAddrEntry 5 }
cfprVnicIpV6StaticAddrPrefix OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6StaticAddr:prefix managed
object property"
::= { cfprVnicIpV6StaticAddrEntry 6 }
cfprVnicIpV6StaticAddrPrimDns OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6StaticAddr:primDns managed
object property"
::= { cfprVnicIpV6StaticAddrEntry 7 }
cfprVnicIpV6StaticAddrSecDns OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpV6StaticAddr:secDns managed
object property"
::= { cfprVnicIpV6StaticAddrEntry 8 }
cfprVnicIpcTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIpcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc managed object table"
::= { cfprVnicObjects 43 }
cfprVnicIpcEntry OBJECT-TYPE
SYNTAX CfprVnicIpcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIpcTable table."
INDEX { cfprVnicIpcInstanceId }
::= { cfprVnicIpcTable 1 }
CfprVnicIpcEntry ::= SEQUENCE {
cfprVnicIpcInstanceId CfprManagedObjectId,
cfprVnicIpcDn CfprManagedObjectDn,
cfprVnicIpcRn SnmpAdminString,
cfprVnicIpcAdaptorProfileName SnmpAdminString,
cfprVnicIpcAddr MacAddress,
cfprVnicIpcAdminHostPort CfprFabricHostPortId,
cfprVnicIpcAdminVcon SnmpAdminString,
cfprVnicIpcAppRole CfprVnicAppRole,
cfprVnicIpcBootDev CfprVnicVnicBootDev,
cfprVnicIpcConfigQualifier CfprVnicConfigIssues,
cfprVnicIpcConfigState CfprLsConfigState,
cfprVnicIpcEquipmentDn SnmpAdminString,
cfprVnicIpcIdentPoolName SnmpAdminString,
cfprVnicIpcInstType CfprVnicInstantiation,
cfprVnicIpcMtu Gauge32,
cfprVnicIpcName SnmpAdminString,
cfprVnicIpcNwCtrlPolicyName SnmpAdminString,
cfprVnicIpcNwTemplName SnmpAdminString,
cfprVnicIpcOperAdaptorProfileName SnmpAdminString,
cfprVnicIpcOperHostPort CfprVnicVnicOperHostPort,
cfprVnicIpcOperIdentPoolName SnmpAdminString,
cfprVnicIpcOperNwCtrlPolicyName SnmpAdminString,
cfprVnicIpcOperNwTemplName SnmpAdminString,
cfprVnicIpcOperOrder Gauge32,
cfprVnicIpcOperPinToGroupName SnmpAdminString,
cfprVnicIpcOperQosPolicyName SnmpAdminString,
cfprVnicIpcOperSpeed Gauge32,
cfprVnicIpcOperStatsPolicyName SnmpAdminString,
cfprVnicIpcOperVcon SnmpAdminString,
cfprVnicIpcOrder Gauge32,
cfprVnicIpcOwner CfprVnicConnectionOwner,
cfprVnicIpcPinToGroupName SnmpAdminString,
cfprVnicIpcQosPolicyName SnmpAdminString,
cfprVnicIpcStatsPolicyName SnmpAdminString,
cfprVnicIpcSwitchId CfprVnicEtherBaseSwitchId,
cfprVnicIpcType CfprVnicIpcType
}
cfprVnicIpcInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIpcEntry 1 }
cfprVnicIpcDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:dn managed object property"
::= { cfprVnicIpcEntry 2 }
cfprVnicIpcRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:rn managed object property"
::= { cfprVnicIpcEntry 3 }
cfprVnicIpcAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:adaptorProfileName managed
object property"
::= { cfprVnicIpcEntry 4 }
cfprVnicIpcAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:addr managed object property"
::= { cfprVnicIpcEntry 5 }
cfprVnicIpcAdminHostPort OBJECT-TYPE
SYNTAX CfprFabricHostPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:adminHostPort managed object property"
::= { cfprVnicIpcEntry 6 }
cfprVnicIpcAdminVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:adminVcon managed object property"
::= { cfprVnicIpcEntry 7 }
cfprVnicIpcAppRole OBJECT-TYPE
SYNTAX CfprVnicAppRole
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:appRole managed object property"
::= { cfprVnicIpcEntry 8 }
cfprVnicIpcBootDev OBJECT-TYPE
SYNTAX CfprVnicVnicBootDev
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:bootDev managed object property"
::= { cfprVnicIpcEntry 9 }
cfprVnicIpcConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:configQualifier managed object property"
::= { cfprVnicIpcEntry 10 }
cfprVnicIpcConfigState OBJECT-TYPE
SYNTAX CfprLsConfigState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:configState managed object property"
::= { cfprVnicIpcEntry 11 }
cfprVnicIpcEquipmentDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:equipmentDn managed object property"
::= { cfprVnicIpcEntry 12 }
cfprVnicIpcIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:identPoolName managed object property"
::= { cfprVnicIpcEntry 13 }
cfprVnicIpcInstType OBJECT-TYPE
SYNTAX CfprVnicInstantiation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:instType managed object property"
::= { cfprVnicIpcEntry 14 }
cfprVnicIpcMtu OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:mtu managed object property"
::= { cfprVnicIpcEntry 15 }
cfprVnicIpcName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:name managed object property"
::= { cfprVnicIpcEntry 16 }
cfprVnicIpcNwCtrlPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:nwCtrlPolicyName managed
object property"
::= { cfprVnicIpcEntry 17 }
cfprVnicIpcNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:nwTemplName managed object property"
::= { cfprVnicIpcEntry 18 }
cfprVnicIpcOperAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:operAdaptorProfileName
managed object property"
::= { cfprVnicIpcEntry 19 }
cfprVnicIpcOperHostPort OBJECT-TYPE
SYNTAX CfprVnicVnicOperHostPort
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:operHostPort managed object property"
::= { cfprVnicIpcEntry 20 }
cfprVnicIpcOperIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:operIdentPoolName managed
object property"
::= { cfprVnicIpcEntry 21 }
cfprVnicIpcOperNwCtrlPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:operNwCtrlPolicyName
managed object property"
::= { cfprVnicIpcEntry 22 }
cfprVnicIpcOperNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:operNwTemplName managed object property"
::= { cfprVnicIpcEntry 23 }
cfprVnicIpcOperOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:operOrder managed object property"
::= { cfprVnicIpcEntry 24 }
cfprVnicIpcOperPinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:operPinToGroupName managed
object property"
::= { cfprVnicIpcEntry 25 }
cfprVnicIpcOperQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:operQosPolicyName managed
object property"
::= { cfprVnicIpcEntry 26 }
cfprVnicIpcOperSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:operSpeed managed object property"
::= { cfprVnicIpcEntry 27 }
cfprVnicIpcOperStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:operStatsPolicyName managed
object property"
::= { cfprVnicIpcEntry 28 }
cfprVnicIpcOperVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:operVcon managed object property"
::= { cfprVnicIpcEntry 29 }
cfprVnicIpcOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:order managed object property"
::= { cfprVnicIpcEntry 30 }
cfprVnicIpcOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:owner managed object property"
::= { cfprVnicIpcEntry 31 }
cfprVnicIpcPinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:pinToGroupName managed object property"
::= { cfprVnicIpcEntry 32 }
cfprVnicIpcQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:qosPolicyName managed object property"
::= { cfprVnicIpcEntry 33 }
cfprVnicIpcStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:statsPolicyName managed object property"
::= { cfprVnicIpcEntry 34 }
cfprVnicIpcSwitchId OBJECT-TYPE
SYNTAX CfprVnicEtherBaseSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:switchId managed object property"
::= { cfprVnicIpcEntry 35 }
cfprVnicIpcType OBJECT-TYPE
SYNTAX CfprVnicIpcType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Ipc:type managed object property"
::= { cfprVnicIpcEntry 36 }
cfprVnicIpcIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIpcIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf managed object table"
::= { cfprVnicObjects 44 }
cfprVnicIpcIfEntry OBJECT-TYPE
SYNTAX CfprVnicIpcIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIpcIfTable table."
INDEX { cfprVnicIpcIfInstanceId }
::= { cfprVnicIpcIfTable 1 }
CfprVnicIpcIfEntry ::= SEQUENCE {
cfprVnicIpcIfInstanceId CfprManagedObjectId,
cfprVnicIpcIfDn CfprManagedObjectDn,
cfprVnicIpcIfRn SnmpAdminString,
cfprVnicIpcIfAddr MacAddress,
cfprVnicIpcIfConfigQualifier CfprVnicConfigIssues,
cfprVnicIpcIfDefaultNet TruthValue,
cfprVnicIpcIfName SnmpAdminString,
cfprVnicIpcIfOperState CfprVnicIfOperState,
cfprVnicIpcIfOperVnetDn SnmpAdminString,
cfprVnicIpcIfOperVnetName SnmpAdminString,
cfprVnicIpcIfOwner CfprVnicConnectionOwner,
cfprVnicIpcIfPubNwId Gauge32,
cfprVnicIpcIfSharing CfprFabricVlanSharingType,
cfprVnicIpcIfSwitchId CfprVnicL2IfSwitchId,
cfprVnicIpcIfType CfprVnicAIpcIfType,
cfprVnicIpcIfVnet Gauge32
}
cfprVnicIpcIfInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIpcIfEntry 1 }
cfprVnicIpcIfDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:dn managed object property"
::= { cfprVnicIpcIfEntry 2 }
cfprVnicIpcIfRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:rn managed object property"
::= { cfprVnicIpcIfEntry 3 }
cfprVnicIpcIfAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:addr managed object property"
::= { cfprVnicIpcIfEntry 4 }
cfprVnicIpcIfConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:configQualifier managed
object property"
::= { cfprVnicIpcIfEntry 5 }
cfprVnicIpcIfDefaultNet OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:defaultNet managed object property"
::= { cfprVnicIpcIfEntry 6 }
cfprVnicIpcIfName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:name managed object property"
::= { cfprVnicIpcIfEntry 7 }
cfprVnicIpcIfOperState OBJECT-TYPE
SYNTAX CfprVnicIfOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:operState managed object property"
::= { cfprVnicIpcIfEntry 8 }
cfprVnicIpcIfOperVnetDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:operVnetDn managed object property"
::= { cfprVnicIpcIfEntry 9 }
cfprVnicIpcIfOperVnetName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:operVnetName managed object property"
::= { cfprVnicIpcIfEntry 10 }
cfprVnicIpcIfOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:owner managed object property"
::= { cfprVnicIpcIfEntry 11 }
cfprVnicIpcIfPubNwId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:pubNwId managed object property"
::= { cfprVnicIpcIfEntry 12 }
cfprVnicIpcIfSharing OBJECT-TYPE
SYNTAX CfprFabricVlanSharingType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:sharing managed object property"
::= { cfprVnicIpcIfEntry 13 }
cfprVnicIpcIfSwitchId OBJECT-TYPE
SYNTAX CfprVnicL2IfSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:switchId managed object property"
::= { cfprVnicIpcIfEntry 14 }
cfprVnicIpcIfType OBJECT-TYPE
SYNTAX CfprVnicAIpcIfType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:type managed object property"
::= { cfprVnicIpcIfEntry 15 }
cfprVnicIpcIfVnet OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IpcIf:vnet managed object property"
::= { cfprVnicIpcIfEntry 16 }
cfprVnicIqnHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicIqnHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IqnHistory managed object table"
::= { cfprVnicObjects 45 }
cfprVnicIqnHistoryEntry OBJECT-TYPE
SYNTAX CfprVnicIqnHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicIqnHistoryTable table."
INDEX { cfprVnicIqnHistoryInstanceId }
::= { cfprVnicIqnHistoryTable 1 }
CfprVnicIqnHistoryEntry ::= SEQUENCE {
cfprVnicIqnHistoryInstanceId CfprManagedObjectId,
cfprVnicIqnHistoryDn CfprManagedObjectDn,
cfprVnicIqnHistoryRn SnmpAdminString,
cfprVnicIqnHistoryOldInitiatorName SnmpAdminString
}
cfprVnicIqnHistoryInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicIqnHistoryEntry 1 }
cfprVnicIqnHistoryDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IqnHistory:dn managed object property"
::= { cfprVnicIqnHistoryEntry 2 }
cfprVnicIqnHistoryRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IqnHistory:rn managed object property"
::= { cfprVnicIqnHistoryEntry 3 }
cfprVnicIqnHistoryOldInitiatorName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:IqnHistory:oldInitiatorName
managed object property"
::= { cfprVnicIqnHistoryEntry 4 }
cfprVnicLanConnPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicLanConnPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnPolicy managed object table"
::= { cfprVnicObjects 46 }
cfprVnicLanConnPolicyEntry OBJECT-TYPE
SYNTAX CfprVnicLanConnPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicLanConnPolicyTable table."
INDEX { cfprVnicLanConnPolicyInstanceId }
::= { cfprVnicLanConnPolicyTable 1 }
CfprVnicLanConnPolicyEntry ::= SEQUENCE {
cfprVnicLanConnPolicyInstanceId CfprManagedObjectId,
cfprVnicLanConnPolicyDn CfprManagedObjectDn,
cfprVnicLanConnPolicyRn SnmpAdminString,
cfprVnicLanConnPolicyDescr SnmpAdminString,
cfprVnicLanConnPolicyFltAggr Unsigned64,
cfprVnicLanConnPolicyIntId SnmpAdminString,
cfprVnicLanConnPolicyName SnmpAdminString,
cfprVnicLanConnPolicyPolicyLevel Gauge32,
cfprVnicLanConnPolicyPolicyOwner CfprPolicyPolicyOwner
}
cfprVnicLanConnPolicyInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicLanConnPolicyEntry 1 }
cfprVnicLanConnPolicyDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnPolicy:dn managed object property"
::= { cfprVnicLanConnPolicyEntry 2 }
cfprVnicLanConnPolicyRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnPolicy:rn managed object property"
::= { cfprVnicLanConnPolicyEntry 3 }
cfprVnicLanConnPolicyDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnPolicy:descr managed object property"
::= { cfprVnicLanConnPolicyEntry 4 }
cfprVnicLanConnPolicyFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnPolicy:fltAggr managed
object property"
::= { cfprVnicLanConnPolicyEntry 5 }
cfprVnicLanConnPolicyIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnPolicy:intId managed object property"
::= { cfprVnicLanConnPolicyEntry 6 }
cfprVnicLanConnPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnPolicy:name managed object property"
::= { cfprVnicLanConnPolicyEntry 7 }
cfprVnicLanConnPolicyPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnPolicy:policyLevel
managed object property"
::= { cfprVnicLanConnPolicyEntry 8 }
cfprVnicLanConnPolicyPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnPolicy:policyOwner
managed object property"
::= { cfprVnicLanConnPolicyEntry 9 }
cfprVnicLanConnTemplTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicLanConnTemplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl managed object table"
::= { cfprVnicObjects 47 }
cfprVnicLanConnTemplEntry OBJECT-TYPE
SYNTAX CfprVnicLanConnTemplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicLanConnTemplTable table."
INDEX { cfprVnicLanConnTemplInstanceId }
::= { cfprVnicLanConnTemplTable 1 }
CfprVnicLanConnTemplEntry ::= SEQUENCE {
cfprVnicLanConnTemplInstanceId CfprManagedObjectId,
cfprVnicLanConnTemplDn CfprManagedObjectDn,
cfprVnicLanConnTemplRn SnmpAdminString,
cfprVnicLanConnTemplDescr SnmpAdminString,
cfprVnicLanConnTemplIdentPoolName SnmpAdminString,
cfprVnicLanConnTemplIntId SnmpAdminString,
cfprVnicLanConnTemplMtu Gauge32,
cfprVnicLanConnTemplName SnmpAdminString,
cfprVnicLanConnTemplNwCtrlPolicyName SnmpAdminString,
cfprVnicLanConnTemplOperIdentPoolName SnmpAdminString,
cfprVnicLanConnTemplOperNwCtrlPolicyName SnmpAdminString,
cfprVnicLanConnTemplOperQosPolicyName SnmpAdminString,
cfprVnicLanConnTemplOperStatsPolicyName SnmpAdminString,
cfprVnicLanConnTemplPinToGroupName SnmpAdminString,
cfprVnicLanConnTemplPolicyLevel Gauge32,
cfprVnicLanConnTemplPolicyOwner CfprPolicyPolicyOwner,
cfprVnicLanConnTemplQosPolicyName SnmpAdminString,
cfprVnicLanConnTemplStatsPolicyName SnmpAdminString,
cfprVnicLanConnTemplSwitchId CfprVnicLanConnTemplSwitchId,
cfprVnicLanConnTemplTarget CfprVnicTemplateTarget,
cfprVnicLanConnTemplTemplType CfprVnicTemplateType
}
cfprVnicLanConnTemplInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicLanConnTemplEntry 1 }
cfprVnicLanConnTemplDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:dn managed object property"
::= { cfprVnicLanConnTemplEntry 2 }
cfprVnicLanConnTemplRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:rn managed object property"
::= { cfprVnicLanConnTemplEntry 3 }
cfprVnicLanConnTemplDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:descr managed object property"
::= { cfprVnicLanConnTemplEntry 4 }
cfprVnicLanConnTemplIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:identPoolName
managed object property"
::= { cfprVnicLanConnTemplEntry 5 }
cfprVnicLanConnTemplIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:intId managed object property"
::= { cfprVnicLanConnTemplEntry 6 }
cfprVnicLanConnTemplMtu OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:mtu managed object property"
::= { cfprVnicLanConnTemplEntry 7 }
cfprVnicLanConnTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:name managed object property"
::= { cfprVnicLanConnTemplEntry 8 }
cfprVnicLanConnTemplNwCtrlPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:nwCtrlPolicyName
managed object property"
::= { cfprVnicLanConnTemplEntry 9 }
cfprVnicLanConnTemplOperIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:operIdentPoolName
managed object property"
::= { cfprVnicLanConnTemplEntry 10 }
cfprVnicLanConnTemplOperNwCtrlPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:operNwCtrlPolicyName
managed object property"
::= { cfprVnicLanConnTemplEntry 11 }
cfprVnicLanConnTemplOperQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:operQosPolicyName
managed object property"
::= { cfprVnicLanConnTemplEntry 12 }
cfprVnicLanConnTemplOperStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:operStatsPolicyName
managed object property"
::= { cfprVnicLanConnTemplEntry 13 }
cfprVnicLanConnTemplPinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:pinToGroupName
managed object property"
::= { cfprVnicLanConnTemplEntry 14 }
cfprVnicLanConnTemplPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:policyLevel
managed object property"
::= { cfprVnicLanConnTemplEntry 15 }
cfprVnicLanConnTemplPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:policyOwner
managed object property"
::= { cfprVnicLanConnTemplEntry 16 }
cfprVnicLanConnTemplQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:qosPolicyName
managed object property"
::= { cfprVnicLanConnTemplEntry 17 }
cfprVnicLanConnTemplStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:statsPolicyName
managed object property"
::= { cfprVnicLanConnTemplEntry 18 }
cfprVnicLanConnTemplSwitchId OBJECT-TYPE
SYNTAX CfprVnicLanConnTemplSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:switchId managed
object property"
::= { cfprVnicLanConnTemplEntry 19 }
cfprVnicLanConnTemplTarget OBJECT-TYPE
SYNTAX CfprVnicTemplateTarget
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:target managed object property"
::= { cfprVnicLanConnTemplEntry 20 }
cfprVnicLanConnTemplTemplType OBJECT-TYPE
SYNTAX CfprVnicTemplateType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LanConnTempl:templType managed
object property"
::= { cfprVnicLanConnTemplEntry 21 }
cfprVnicLifVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicLifVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan managed object table"
::= { cfprVnicObjects 48 }
cfprVnicLifVlanEntry OBJECT-TYPE
SYNTAX CfprVnicLifVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicLifVlanTable table."
INDEX { cfprVnicLifVlanInstanceId }
::= { cfprVnicLifVlanTable 1 }
CfprVnicLifVlanEntry ::= SEQUENCE {
cfprVnicLifVlanInstanceId CfprManagedObjectId,
cfprVnicLifVlanDn CfprManagedObjectDn,
cfprVnicLifVlanRn SnmpAdminString,
cfprVnicLifVlanAddr MacAddress,
cfprVnicLifVlanConfigQualifier CfprVnicConfigIssues,
cfprVnicLifVlanDefaultNet TruthValue,
cfprVnicLifVlanName SnmpAdminString,
cfprVnicLifVlanOperState CfprVnicIfOperState,
cfprVnicLifVlanOperVnetDn SnmpAdminString,
cfprVnicLifVlanOperVnetName SnmpAdminString,
cfprVnicLifVlanOwner CfprVnicConnectionOwner,
cfprVnicLifVlanPubNwId Gauge32,
cfprVnicLifVlanSharing CfprFabricVlanSharingType,
cfprVnicLifVlanSwitchId CfprVnicL2IfSwitchId,
cfprVnicLifVlanType CfprVnicAEtherIfType,
cfprVnicLifVlanVnet Gauge32
}
cfprVnicLifVlanInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicLifVlanEntry 1 }
cfprVnicLifVlanDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:dn managed object property"
::= { cfprVnicLifVlanEntry 2 }
cfprVnicLifVlanRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:rn managed object property"
::= { cfprVnicLifVlanEntry 3 }
cfprVnicLifVlanAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:addr managed object property"
::= { cfprVnicLifVlanEntry 4 }
cfprVnicLifVlanConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:configQualifier managed
object property"
::= { cfprVnicLifVlanEntry 5 }
cfprVnicLifVlanDefaultNet OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:defaultNet managed object property"
::= { cfprVnicLifVlanEntry 6 }
cfprVnicLifVlanName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:name managed object property"
::= { cfprVnicLifVlanEntry 7 }
cfprVnicLifVlanOperState OBJECT-TYPE
SYNTAX CfprVnicIfOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:operState managed object property"
::= { cfprVnicLifVlanEntry 8 }
cfprVnicLifVlanOperVnetDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:operVnetDn managed object property"
::= { cfprVnicLifVlanEntry 9 }
cfprVnicLifVlanOperVnetName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:operVnetName managed
object property"
::= { cfprVnicLifVlanEntry 10 }
cfprVnicLifVlanOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:owner managed object property"
::= { cfprVnicLifVlanEntry 11 }
cfprVnicLifVlanPubNwId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:pubNwId managed object property"
::= { cfprVnicLifVlanEntry 12 }
cfprVnicLifVlanSharing OBJECT-TYPE
SYNTAX CfprFabricVlanSharingType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:sharing managed object property"
::= { cfprVnicLifVlanEntry 13 }
cfprVnicLifVlanSwitchId OBJECT-TYPE
SYNTAX CfprVnicL2IfSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:switchId managed object property"
::= { cfprVnicLifVlanEntry 14 }
cfprVnicLifVlanType OBJECT-TYPE
SYNTAX CfprVnicAEtherIfType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:type managed object property"
::= { cfprVnicLifVlanEntry 15 }
cfprVnicLifVlanVnet OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVlan:vnet managed object property"
::= { cfprVnicLifVlanEntry 16 }
cfprVnicLifVsanTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicLifVsanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan managed object table"
::= { cfprVnicObjects 49 }
cfprVnicLifVsanEntry OBJECT-TYPE
SYNTAX CfprVnicLifVsanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicLifVsanTable table."
INDEX { cfprVnicLifVsanInstanceId }
::= { cfprVnicLifVsanTable 1 }
CfprVnicLifVsanEntry ::= SEQUENCE {
cfprVnicLifVsanInstanceId CfprManagedObjectId,
cfprVnicLifVsanDn CfprManagedObjectDn,
cfprVnicLifVsanRn SnmpAdminString,
cfprVnicLifVsanConfigQualifier CfprVnicConfigIssues,
cfprVnicLifVsanInitiator Unsigned64,
cfprVnicLifVsanName SnmpAdminString,
cfprVnicLifVsanOperState CfprVnicIfOperState,
cfprVnicLifVsanOperVnetDn SnmpAdminString,
cfprVnicLifVsanOperVnetName SnmpAdminString,
cfprVnicLifVsanOwner CfprVnicConnectionOwner,
cfprVnicLifVsanPubNwId Gauge32,
cfprVnicLifVsanSharing CfprFabricVlanSharingType,
cfprVnicLifVsanSwitchId CfprVnicL2IfSwitchId,
cfprVnicLifVsanType CfprVnicAFcIfType,
cfprVnicLifVsanVnet Gauge32
}
cfprVnicLifVsanInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicLifVsanEntry 1 }
cfprVnicLifVsanDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:dn managed object property"
::= { cfprVnicLifVsanEntry 2 }
cfprVnicLifVsanRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:rn managed object property"
::= { cfprVnicLifVsanEntry 3 }
cfprVnicLifVsanConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:configQualifier managed
object property"
::= { cfprVnicLifVsanEntry 4 }
cfprVnicLifVsanInitiator OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:initiator managed object property"
::= { cfprVnicLifVsanEntry 5 }
cfprVnicLifVsanName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:name managed object property"
::= { cfprVnicLifVsanEntry 6 }
cfprVnicLifVsanOperState OBJECT-TYPE
SYNTAX CfprVnicIfOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:operState managed object property"
::= { cfprVnicLifVsanEntry 7 }
cfprVnicLifVsanOperVnetDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:operVnetDn managed object property"
::= { cfprVnicLifVsanEntry 8 }
cfprVnicLifVsanOperVnetName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:operVnetName managed
object property"
::= { cfprVnicLifVsanEntry 9 }
cfprVnicLifVsanOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:owner managed object property"
::= { cfprVnicLifVsanEntry 10 }
cfprVnicLifVsanPubNwId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:pubNwId managed object property"
::= { cfprVnicLifVsanEntry 11 }
cfprVnicLifVsanSharing OBJECT-TYPE
SYNTAX CfprFabricVlanSharingType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:sharing managed object property"
::= { cfprVnicLifVsanEntry 12 }
cfprVnicLifVsanSwitchId OBJECT-TYPE
SYNTAX CfprVnicL2IfSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:switchId managed object property"
::= { cfprVnicLifVsanEntry 13 }
cfprVnicLifVsanType OBJECT-TYPE
SYNTAX CfprVnicAFcIfType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:type managed object property"
::= { cfprVnicLifVsanEntry 14 }
cfprVnicLifVsanVnet OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:LifVsan:vnet managed object property"
::= { cfprVnicLifVsanEntry 15 }
cfprVnicLunTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicLunEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Lun managed object table"
::= { cfprVnicObjects 50 }
cfprVnicLunEntry OBJECT-TYPE
SYNTAX CfprVnicLunEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicLunTable table."
INDEX { cfprVnicLunInstanceId }
::= { cfprVnicLunTable 1 }
CfprVnicLunEntry ::= SEQUENCE {
cfprVnicLunInstanceId CfprManagedObjectId,
cfprVnicLunDn CfprManagedObjectDn,
cfprVnicLunRn SnmpAdminString,
cfprVnicLunBootable TruthValue,
cfprVnicLunId CfprVnicLunId
}
cfprVnicLunInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicLunEntry 1 }
cfprVnicLunDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Lun:dn managed object property"
::= { cfprVnicLunEntry 2 }
cfprVnicLunRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Lun:rn managed object property"
::= { cfprVnicLunEntry 3 }
cfprVnicLunBootable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Lun:bootable managed object property"
::= { cfprVnicLunEntry 4 }
cfprVnicLunId OBJECT-TYPE
SYNTAX CfprVnicLunId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Lun:id managed object property"
::= { cfprVnicLunEntry 5 }
cfprVnicMacHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicMacHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:MacHistory managed object table"
::= { cfprVnicObjects 51 }
cfprVnicMacHistoryEntry OBJECT-TYPE
SYNTAX CfprVnicMacHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicMacHistoryTable table."
INDEX { cfprVnicMacHistoryInstanceId }
::= { cfprVnicMacHistoryTable 1 }
CfprVnicMacHistoryEntry ::= SEQUENCE {
cfprVnicMacHistoryInstanceId CfprManagedObjectId,
cfprVnicMacHistoryDn CfprManagedObjectDn,
cfprVnicMacHistoryRn SnmpAdminString,
cfprVnicMacHistoryOldaddr MacAddress
}
cfprVnicMacHistoryInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicMacHistoryEntry 1 }
cfprVnicMacHistoryDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:MacHistory:dn managed object property"
::= { cfprVnicMacHistoryEntry 2 }
cfprVnicMacHistoryRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:MacHistory:rn managed object property"
::= { cfprVnicMacHistoryEntry 3 }
cfprVnicMacHistoryOldaddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:MacHistory:oldaddr managed object property"
::= { cfprVnicMacHistoryEntry 4 }
cfprVnicOProfileAliasTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicOProfileAliasEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:OProfileAlias managed object table"
::= { cfprVnicObjects 52 }
cfprVnicOProfileAliasEntry OBJECT-TYPE
SYNTAX CfprVnicOProfileAliasEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicOProfileAliasTable table."
INDEX { cfprVnicOProfileAliasInstanceId }
::= { cfprVnicOProfileAliasTable 1 }
CfprVnicOProfileAliasEntry ::= SEQUENCE {
cfprVnicOProfileAliasInstanceId CfprManagedObjectId,
cfprVnicOProfileAliasDn CfprManagedObjectDn,
cfprVnicOProfileAliasRn SnmpAdminString,
cfprVnicOProfileAliasAlias SnmpAdminString,
cfprVnicOProfileAliasMgmtPlane CfprVmMgmtPlane,
cfprVnicOProfileAliasVSwitchId SnmpAdminString,
cfprVnicOProfileAliasVSwitchName SnmpAdminString
}
cfprVnicOProfileAliasInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicOProfileAliasEntry 1 }
cfprVnicOProfileAliasDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:OProfileAlias:dn managed object property"
::= { cfprVnicOProfileAliasEntry 2 }
cfprVnicOProfileAliasRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:OProfileAlias:rn managed object property"
::= { cfprVnicOProfileAliasEntry 3 }
cfprVnicOProfileAliasAlias OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:OProfileAlias:alias managed object property"
::= { cfprVnicOProfileAliasEntry 4 }
cfprVnicOProfileAliasMgmtPlane OBJECT-TYPE
SYNTAX CfprVmMgmtPlane
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:OProfileAlias:mgmtPlane managed
object property"
::= { cfprVnicOProfileAliasEntry 5 }
cfprVnicOProfileAliasVSwitchId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:OProfileAlias:vSwitchId managed
object property"
::= { cfprVnicOProfileAliasEntry 6 }
cfprVnicOProfileAliasVSwitchName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:OProfileAlias:vSwitchName
managed object property"
::= { cfprVnicOProfileAliasEntry 7 }
cfprVnicProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile managed object table"
::= { cfprVnicObjects 53 }
cfprVnicProfileEntry OBJECT-TYPE
SYNTAX CfprVnicProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicProfileTable table."
INDEX { cfprVnicProfileInstanceId }
::= { cfprVnicProfileTable 1 }
CfprVnicProfileEntry ::= SEQUENCE {
cfprVnicProfileInstanceId CfprManagedObjectId,
cfprVnicProfileDn CfprManagedObjectDn,
cfprVnicProfileRn SnmpAdminString,
cfprVnicProfileCdp CfprNwctrlAdminState,
cfprVnicProfileConfigQualifier CfprVnicProfileConfigQualifier,
cfprVnicProfileCos Gauge32,
cfprVnicProfileDescr SnmpAdminString,
cfprVnicProfileForgeMac CfprDpsecForgedTransmit,
cfprVnicProfileHostNwIOPerf CfprVnicHostNwIOPerfPref,
cfprVnicProfileIntId SnmpAdminString,
cfprVnicProfileMacRegisterMode CfprNwctrlRegistrationMode,
cfprVnicProfileMaxPorts Gauge32,
cfprVnicProfileName SnmpAdminString,
cfprVnicProfileNwCtrlPolicyName SnmpAdminString,
cfprVnicProfileOperNwCtrlPolicyName SnmpAdminString,
cfprVnicProfileOperQosPolicyName SnmpAdminString,
cfprVnicProfilePinToGroupName SnmpAdminString,
cfprVnicProfilePolicyLevel Gauge32,
cfprVnicProfilePolicyOwner CfprPolicyPolicyOwner,
cfprVnicProfilePortProfileUuid SnmpAdminString,
cfprVnicProfilePrimaryVlanId Gauge32,
cfprVnicProfileQosPolicyDn SnmpAdminString,
cfprVnicProfileQosPolicyId SnmpAdminString,
cfprVnicProfileQosPolicyName SnmpAdminString,
cfprVnicProfileSwABorderAggrPort Gauge32,
cfprVnicProfileSwABorderPort Gauge32,
cfprVnicProfileSwABorderSlot Gauge32,
cfprVnicProfileSwBBorderAggrPort Gauge32,
cfprVnicProfileSwBBorderPort Gauge32,
cfprVnicProfileSwBBorderSlot Gauge32,
cfprVnicProfileType CfprVnicPortProfileType,
cfprVnicProfileUplinkFailAction CfprNwctrlLinkFailAction
}
cfprVnicProfileInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicProfileEntry 1 }
cfprVnicProfileDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:dn managed object property"
::= { cfprVnicProfileEntry 2 }
cfprVnicProfileRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:rn managed object property"
::= { cfprVnicProfileEntry 3 }
cfprVnicProfileCdp OBJECT-TYPE
SYNTAX CfprNwctrlAdminState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:cdp managed object property"
::= { cfprVnicProfileEntry 4 }
cfprVnicProfileConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicProfileConfigQualifier
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:configQualifier managed
object property"
::= { cfprVnicProfileEntry 5 }
cfprVnicProfileCos OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:cos managed object property"
::= { cfprVnicProfileEntry 6 }
cfprVnicProfileDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:descr managed object property"
::= { cfprVnicProfileEntry 7 }
cfprVnicProfileForgeMac OBJECT-TYPE
SYNTAX CfprDpsecForgedTransmit
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:forgeMac managed object property"
::= { cfprVnicProfileEntry 8 }
cfprVnicProfileHostNwIOPerf OBJECT-TYPE
SYNTAX CfprVnicHostNwIOPerfPref
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:hostNwIOPerf managed
object property"
::= { cfprVnicProfileEntry 9 }
cfprVnicProfileIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:intId managed object property"
::= { cfprVnicProfileEntry 10 }
cfprVnicProfileMacRegisterMode OBJECT-TYPE
SYNTAX CfprNwctrlRegistrationMode
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:macRegisterMode managed
object property"
::= { cfprVnicProfileEntry 11 }
cfprVnicProfileMaxPorts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:maxPorts managed object property"
::= { cfprVnicProfileEntry 12 }
cfprVnicProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:name managed object property"
::= { cfprVnicProfileEntry 13 }
cfprVnicProfileNwCtrlPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:nwCtrlPolicyName
managed object property"
::= { cfprVnicProfileEntry 14 }
cfprVnicProfileOperNwCtrlPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:operNwCtrlPolicyName
managed object property"
::= { cfprVnicProfileEntry 15 }
cfprVnicProfileOperQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:operQosPolicyName
managed object property"
::= { cfprVnicProfileEntry 16 }
cfprVnicProfilePinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:pinToGroupName managed
object property"
::= { cfprVnicProfileEntry 17 }
cfprVnicProfilePolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:policyLevel managed object property"
::= { cfprVnicProfileEntry 18 }
cfprVnicProfilePolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:policyOwner managed object property"
::= { cfprVnicProfileEntry 19 }
cfprVnicProfilePortProfileUuid OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:portProfileUuid managed
object property"
::= { cfprVnicProfileEntry 20 }
cfprVnicProfilePrimaryVlanId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:primaryVlanId managed
object property"
::= { cfprVnicProfileEntry 21 }
cfprVnicProfileQosPolicyDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:qosPolicyDn managed object property"
::= { cfprVnicProfileEntry 22 }
cfprVnicProfileQosPolicyId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:qosPolicyId managed object property"
::= { cfprVnicProfileEntry 23 }
cfprVnicProfileQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:qosPolicyName managed
object property"
::= { cfprVnicProfileEntry 24 }
cfprVnicProfileSwABorderAggrPort OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:swABorderAggrPort
managed object property"
::= { cfprVnicProfileEntry 25 }
cfprVnicProfileSwABorderPort OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:swABorderPort managed
object property"
::= { cfprVnicProfileEntry 26 }
cfprVnicProfileSwABorderSlot OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:swABorderSlot managed
object property"
::= { cfprVnicProfileEntry 27 }
cfprVnicProfileSwBBorderAggrPort OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:swBBorderAggrPort
managed object property"
::= { cfprVnicProfileEntry 28 }
cfprVnicProfileSwBBorderPort OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:swBBorderPort managed
object property"
::= { cfprVnicProfileEntry 29 }
cfprVnicProfileSwBBorderSlot OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:swBBorderSlot managed
object property"
::= { cfprVnicProfileEntry 30 }
cfprVnicProfileType OBJECT-TYPE
SYNTAX CfprVnicPortProfileType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:type managed object property"
::= { cfprVnicProfileEntry 31 }
cfprVnicProfileUplinkFailAction OBJECT-TYPE
SYNTAX CfprNwctrlLinkFailAction
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Profile:uplinkFailAction
managed object property"
::= { cfprVnicProfileEntry 32 }
cfprVnicProfileAliasTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicProfileAliasEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileAlias managed object table"
::= { cfprVnicObjects 54 }
cfprVnicProfileAliasEntry OBJECT-TYPE
SYNTAX CfprVnicProfileAliasEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicProfileAliasTable table."
INDEX { cfprVnicProfileAliasInstanceId }
::= { cfprVnicProfileAliasTable 1 }
CfprVnicProfileAliasEntry ::= SEQUENCE {
cfprVnicProfileAliasInstanceId CfprManagedObjectId,
cfprVnicProfileAliasDn CfprManagedObjectDn,
cfprVnicProfileAliasRn SnmpAdminString,
cfprVnicProfileAliasAlias SnmpAdminString,
cfprVnicProfileAliasSwUuid SnmpAdminString
}
cfprVnicProfileAliasInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicProfileAliasEntry 1 }
cfprVnicProfileAliasDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileAlias:dn managed object property"
::= { cfprVnicProfileAliasEntry 2 }
cfprVnicProfileAliasRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileAlias:rn managed object property"
::= { cfprVnicProfileAliasEntry 3 }
cfprVnicProfileAliasAlias OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileAlias:alias managed object property"
::= { cfprVnicProfileAliasEntry 4 }
cfprVnicProfileAliasSwUuid OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileAlias:swUuid managed object property"
::= { cfprVnicProfileAliasEntry 5 }
cfprVnicProfileRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicProfileRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileRef managed object table"
::= { cfprVnicObjects 55 }
cfprVnicProfileRefEntry OBJECT-TYPE
SYNTAX CfprVnicProfileRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicProfileRefTable table."
INDEX { cfprVnicProfileRefInstanceId }
::= { cfprVnicProfileRefTable 1 }
CfprVnicProfileRefEntry ::= SEQUENCE {
cfprVnicProfileRefInstanceId CfprManagedObjectId,
cfprVnicProfileRefDn CfprManagedObjectDn,
cfprVnicProfileRefRn SnmpAdminString,
cfprVnicProfileRefName SnmpAdminString,
cfprVnicProfileRefSourceDn SnmpAdminString
}
cfprVnicProfileRefInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicProfileRefEntry 1 }
cfprVnicProfileRefDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileRef:dn managed object property"
::= { cfprVnicProfileRefEntry 2 }
cfprVnicProfileRefRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileRef:rn managed object property"
::= { cfprVnicProfileRefEntry 3 }
cfprVnicProfileRefName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileRef:name managed object property"
::= { cfprVnicProfileRefEntry 4 }
cfprVnicProfileRefSourceDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileRef:sourceDn managed object property"
::= { cfprVnicProfileRefEntry 5 }
cfprVnicProfileSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicProfileSetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet managed object table"
::= { cfprVnicObjects 56 }
cfprVnicProfileSetEntry OBJECT-TYPE
SYNTAX CfprVnicProfileSetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicProfileSetTable table."
INDEX { cfprVnicProfileSetInstanceId }
::= { cfprVnicProfileSetTable 1 }
CfprVnicProfileSetEntry ::= SEQUENCE {
cfprVnicProfileSetInstanceId CfprManagedObjectId,
cfprVnicProfileSetDn CfprManagedObjectDn,
cfprVnicProfileSetRn SnmpAdminString,
cfprVnicProfileSetFltAggr Unsigned64,
cfprVnicProfileSetFsmDescr SnmpAdminString,
cfprVnicProfileSetFsmPrev SnmpAdminString,
cfprVnicProfileSetFsmProgr Gauge32,
cfprVnicProfileSetFsmRmtInvErrCode Gauge32,
cfprVnicProfileSetFsmRmtInvErrDescr SnmpAdminString,
cfprVnicProfileSetFsmRmtInvRslt CfprConditionRemoteInvRslt,
cfprVnicProfileSetFsmStageDescr SnmpAdminString,
cfprVnicProfileSetFsmStamp DateAndTime,
cfprVnicProfileSetFsmStatus SnmpAdminString,
cfprVnicProfileSetFsmTry Gauge32,
cfprVnicProfileSetGenNum Gauge32
}
cfprVnicProfileSetInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicProfileSetEntry 1 }
cfprVnicProfileSetDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:dn managed object property"
::= { cfprVnicProfileSetEntry 2 }
cfprVnicProfileSetRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:rn managed object property"
::= { cfprVnicProfileSetEntry 3 }
cfprVnicProfileSetFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:fltAggr managed object property"
::= { cfprVnicProfileSetEntry 4 }
cfprVnicProfileSetFsmDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:fsmDescr managed object property"
::= { cfprVnicProfileSetEntry 5 }
cfprVnicProfileSetFsmPrev OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:fsmPrev managed object property"
::= { cfprVnicProfileSetEntry 6 }
cfprVnicProfileSetFsmProgr OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:fsmProgr managed object property"
::= { cfprVnicProfileSetEntry 7 }
cfprVnicProfileSetFsmRmtInvErrCode OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:fsmRmtInvErrCode
managed object property"
::= { cfprVnicProfileSetEntry 8 }
cfprVnicProfileSetFsmRmtInvErrDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:fsmRmtInvErrDescr
managed object property"
::= { cfprVnicProfileSetEntry 9 }
cfprVnicProfileSetFsmRmtInvRslt OBJECT-TYPE
SYNTAX CfprConditionRemoteInvRslt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:fsmRmtInvRslt
managed object property"
::= { cfprVnicProfileSetEntry 10 }
cfprVnicProfileSetFsmStageDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:fsmStageDescr
managed object property"
::= { cfprVnicProfileSetEntry 11 }
cfprVnicProfileSetFsmStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:fsmStamp managed object property"
::= { cfprVnicProfileSetEntry 12 }
cfprVnicProfileSetFsmStatus OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:fsmStatus managed
object property"
::= { cfprVnicProfileSetEntry 13 }
cfprVnicProfileSetFsmTry OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:fsmTry managed object property"
::= { cfprVnicProfileSetEntry 14 }
cfprVnicProfileSetGenNum OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSet:genNum managed object property"
::= { cfprVnicProfileSetEntry 15 }
cfprVnicProfileSetFsmTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicProfileSetFsmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsm managed object table"
::= { cfprVnicObjects 57 }
cfprVnicProfileSetFsmEntry OBJECT-TYPE
SYNTAX CfprVnicProfileSetFsmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicProfileSetFsmTable table."
INDEX { cfprVnicProfileSetFsmInstanceId }
::= { cfprVnicProfileSetFsmTable 1 }
CfprVnicProfileSetFsmEntry ::= SEQUENCE {
cfprVnicProfileSetFsmInstanceId CfprManagedObjectId,
cfprVnicProfileSetFsmDn CfprManagedObjectDn,
cfprVnicProfileSetFsmRn SnmpAdminString,
cfprVnicProfileSetFsmCompletionTime DateAndTime,
cfprVnicProfileSetFsmCurrentFsm CfprVnicProfileSetFsmCurrentFsm,
cfprVnicProfileSetFsmDescrData SnmpAdminString,
cfprVnicProfileSetFsmFsmStatus CfprFsmFsmStageStatus,
cfprVnicProfileSetFsmProgress Gauge32,
cfprVnicProfileSetFsmRmtErrCode Gauge32,
cfprVnicProfileSetFsmRmtErrDescr SnmpAdminString,
cfprVnicProfileSetFsmRmtRslt CfprConditionRemoteInvRslt
}
cfprVnicProfileSetFsmInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicProfileSetFsmEntry 1 }
cfprVnicProfileSetFsmDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsm:dn managed object property"
::= { cfprVnicProfileSetFsmEntry 2 }
cfprVnicProfileSetFsmRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsm:rn managed object property"
::= { cfprVnicProfileSetFsmEntry 3 }
cfprVnicProfileSetFsmCompletionTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsm:completionTime
managed object property"
::= { cfprVnicProfileSetFsmEntry 4 }
cfprVnicProfileSetFsmCurrentFsm OBJECT-TYPE
SYNTAX CfprVnicProfileSetFsmCurrentFsm
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsm:currentFsm
managed object property"
::= { cfprVnicProfileSetFsmEntry 5 }
cfprVnicProfileSetFsmDescrData OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsm:descr managed object property"
::= { cfprVnicProfileSetFsmEntry 6 }
cfprVnicProfileSetFsmFsmStatus OBJECT-TYPE
SYNTAX CfprFsmFsmStageStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsm:fsmStatus managed
object property"
::= { cfprVnicProfileSetFsmEntry 7 }
cfprVnicProfileSetFsmProgress OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsm:progress managed
object property"
::= { cfprVnicProfileSetFsmEntry 8 }
cfprVnicProfileSetFsmRmtErrCode OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsm:rmtErrCode
managed object property"
::= { cfprVnicProfileSetFsmEntry 9 }
cfprVnicProfileSetFsmRmtErrDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsm:rmtErrDescr
managed object property"
::= { cfprVnicProfileSetFsmEntry 10 }
cfprVnicProfileSetFsmRmtRslt OBJECT-TYPE
SYNTAX CfprConditionRemoteInvRslt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsm:rmtRslt managed
object property"
::= { cfprVnicProfileSetFsmEntry 11 }
cfprVnicProfileSetFsmStageTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicProfileSetFsmStageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmStage managed object table"
::= { cfprVnicObjects 58 }
cfprVnicProfileSetFsmStageEntry OBJECT-TYPE
SYNTAX CfprVnicProfileSetFsmStageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicProfileSetFsmStageTable table."
INDEX { cfprVnicProfileSetFsmStageInstanceId }
::= { cfprVnicProfileSetFsmStageTable 1 }
CfprVnicProfileSetFsmStageEntry ::= SEQUENCE {
cfprVnicProfileSetFsmStageInstanceId CfprManagedObjectId,
cfprVnicProfileSetFsmStageDn CfprManagedObjectDn,
cfprVnicProfileSetFsmStageRn SnmpAdminString,
cfprVnicProfileSetFsmStageDescrData SnmpAdminString,
cfprVnicProfileSetFsmStageLastUpdateTime DateAndTime,
cfprVnicProfileSetFsmStageName CfprVnicProfileSetFsmStageName,
cfprVnicProfileSetFsmStageOrder Gauge32,
cfprVnicProfileSetFsmStageRetry Gauge32,
cfprVnicProfileSetFsmStageStageStatus CfprFsmFsmStageStatus
}
cfprVnicProfileSetFsmStageInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicProfileSetFsmStageEntry 1 }
cfprVnicProfileSetFsmStageDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmStage:dn managed
object property"
::= { cfprVnicProfileSetFsmStageEntry 2 }
cfprVnicProfileSetFsmStageRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmStage:rn managed
object property"
::= { cfprVnicProfileSetFsmStageEntry 3 }
cfprVnicProfileSetFsmStageDescrData OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmStage:descr
managed object property"
::= { cfprVnicProfileSetFsmStageEntry 4 }
cfprVnicProfileSetFsmStageLastUpdateTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmStage:lastUpdateTime
managed object property"
::= { cfprVnicProfileSetFsmStageEntry 5 }
cfprVnicProfileSetFsmStageName OBJECT-TYPE
SYNTAX CfprVnicProfileSetFsmStageName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmStage:name managed
object property"
::= { cfprVnicProfileSetFsmStageEntry 6 }
cfprVnicProfileSetFsmStageOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmStage:order
managed object property"
::= { cfprVnicProfileSetFsmStageEntry 7 }
cfprVnicProfileSetFsmStageRetry OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmStage:retry
managed object property"
::= { cfprVnicProfileSetFsmStageEntry 8 }
cfprVnicProfileSetFsmStageStageStatus OBJECT-TYPE
SYNTAX CfprFsmFsmStageStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmStage:stageStatus
managed object property"
::= { cfprVnicProfileSetFsmStageEntry 9 }
cfprVnicProfileSetFsmTaskTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicProfileSetFsmTaskEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmTask managed object table"
::= { cfprVnicObjects 59 }
cfprVnicProfileSetFsmTaskEntry OBJECT-TYPE
SYNTAX CfprVnicProfileSetFsmTaskEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicProfileSetFsmTaskTable table."
INDEX { cfprVnicProfileSetFsmTaskInstanceId }
::= { cfprVnicProfileSetFsmTaskTable 1 }
CfprVnicProfileSetFsmTaskEntry ::= SEQUENCE {
cfprVnicProfileSetFsmTaskInstanceId CfprManagedObjectId,
cfprVnicProfileSetFsmTaskDn CfprManagedObjectDn,
cfprVnicProfileSetFsmTaskRn SnmpAdminString,
cfprVnicProfileSetFsmTaskCompletion CfprFsmCompletion,
cfprVnicProfileSetFsmTaskFlags CfprFsmFlags,
cfprVnicProfileSetFsmTaskItem CfprVnicProfileSetFsmTaskItem,
cfprVnicProfileSetFsmTaskSeqId Gauge32
}
cfprVnicProfileSetFsmTaskInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicProfileSetFsmTaskEntry 1 }
cfprVnicProfileSetFsmTaskDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmTask:dn managed
object property"
::= { cfprVnicProfileSetFsmTaskEntry 2 }
cfprVnicProfileSetFsmTaskRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmTask:rn managed
object property"
::= { cfprVnicProfileSetFsmTaskEntry 3 }
cfprVnicProfileSetFsmTaskCompletion OBJECT-TYPE
SYNTAX CfprFsmCompletion
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmTask:completion
managed object property"
::= { cfprVnicProfileSetFsmTaskEntry 4 }
cfprVnicProfileSetFsmTaskFlags OBJECT-TYPE
SYNTAX CfprFsmFlags
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmTask:flags managed
object property"
::= { cfprVnicProfileSetFsmTaskEntry 5 }
cfprVnicProfileSetFsmTaskItem OBJECT-TYPE
SYNTAX CfprVnicProfileSetFsmTaskItem
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmTask:item managed
object property"
::= { cfprVnicProfileSetFsmTaskEntry 6 }
cfprVnicProfileSetFsmTaskSeqId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ProfileSetFsmTask:seqId managed
object property"
::= { cfprVnicProfileSetFsmTaskEntry 7 }
cfprVnicRackServerDiscoveryProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicRackServerDiscoveryProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:RackServerDiscoveryProfile
managed object table"
::= { cfprVnicObjects 60 }
cfprVnicRackServerDiscoveryProfileEntry OBJECT-TYPE
SYNTAX CfprVnicRackServerDiscoveryProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicRackServerDiscoveryProfileTable table."
INDEX { cfprVnicRackServerDiscoveryProfileInstanceId }
::= { cfprVnicRackServerDiscoveryProfileTable 1 }
CfprVnicRackServerDiscoveryProfileEntry ::= SEQUENCE {
cfprVnicRackServerDiscoveryProfileInstanceId CfprManagedObjectId,
cfprVnicRackServerDiscoveryProfileDn CfprManagedObjectDn,
cfprVnicRackServerDiscoveryProfileRn SnmpAdminString,
cfprVnicRackServerDiscoveryProfileDescr SnmpAdminString,
cfprVnicRackServerDiscoveryProfileIntId SnmpAdminString,
cfprVnicRackServerDiscoveryProfileMaxPorts Gauge32,
cfprVnicRackServerDiscoveryProfileName SnmpAdminString,
cfprVnicRackServerDiscoveryProfilePolicyLevel Gauge32,
cfprVnicRackServerDiscoveryProfilePolicyOwner CfprPolicyPolicyOwner
}
cfprVnicRackServerDiscoveryProfileInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicRackServerDiscoveryProfileEntry 1 }
cfprVnicRackServerDiscoveryProfileDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:RackServerDiscoveryProfile:dn
managed object property"
::= { cfprVnicRackServerDiscoveryProfileEntry 2 }
cfprVnicRackServerDiscoveryProfileRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:RackServerDiscoveryProfile:rn
managed object property"
::= { cfprVnicRackServerDiscoveryProfileEntry 3 }
cfprVnicRackServerDiscoveryProfileDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:RackServerDiscoveryProfile:descr
managed object property"
::= { cfprVnicRackServerDiscoveryProfileEntry 4 }
cfprVnicRackServerDiscoveryProfileIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:RackServerDiscoveryProfile:intId
managed object property"
::= { cfprVnicRackServerDiscoveryProfileEntry 5 }
cfprVnicRackServerDiscoveryProfileMaxPorts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:RackServerDiscoveryProfile:maxPorts
managed object property"
::= { cfprVnicRackServerDiscoveryProfileEntry 6 }
cfprVnicRackServerDiscoveryProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:RackServerDiscoveryProfile:name
managed object property"
::= { cfprVnicRackServerDiscoveryProfileEntry 7 }
cfprVnicRackServerDiscoveryProfilePolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:RackServerDiscoveryProfile:policyLevel
managed object property"
::= { cfprVnicRackServerDiscoveryProfileEntry 8 }
cfprVnicRackServerDiscoveryProfilePolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:RackServerDiscoveryProfile:policyOwner
managed object property"
::= { cfprVnicRackServerDiscoveryProfileEntry 9 }
cfprVnicSanConnPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicSanConnPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnPolicy managed object table"
::= { cfprVnicObjects 61 }
cfprVnicSanConnPolicyEntry OBJECT-TYPE
SYNTAX CfprVnicSanConnPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicSanConnPolicyTable table."
INDEX { cfprVnicSanConnPolicyInstanceId }
::= { cfprVnicSanConnPolicyTable 1 }
CfprVnicSanConnPolicyEntry ::= SEQUENCE {
cfprVnicSanConnPolicyInstanceId CfprManagedObjectId,
cfprVnicSanConnPolicyDn CfprManagedObjectDn,
cfprVnicSanConnPolicyRn SnmpAdminString,
cfprVnicSanConnPolicyDescr SnmpAdminString,
cfprVnicSanConnPolicyFltAggr Unsigned64,
cfprVnicSanConnPolicyIntId SnmpAdminString,
cfprVnicSanConnPolicyName SnmpAdminString,
cfprVnicSanConnPolicyPolicyLevel Gauge32,
cfprVnicSanConnPolicyPolicyOwner CfprPolicyPolicyOwner
}
cfprVnicSanConnPolicyInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicSanConnPolicyEntry 1 }
cfprVnicSanConnPolicyDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnPolicy:dn managed object property"
::= { cfprVnicSanConnPolicyEntry 2 }
cfprVnicSanConnPolicyRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnPolicy:rn managed object property"
::= { cfprVnicSanConnPolicyEntry 3 }
cfprVnicSanConnPolicyDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnPolicy:descr managed object property"
::= { cfprVnicSanConnPolicyEntry 4 }
cfprVnicSanConnPolicyFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnPolicy:fltAggr managed
object property"
::= { cfprVnicSanConnPolicyEntry 5 }
cfprVnicSanConnPolicyIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnPolicy:intId managed object property"
::= { cfprVnicSanConnPolicyEntry 6 }
cfprVnicSanConnPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnPolicy:name managed object property"
::= { cfprVnicSanConnPolicyEntry 7 }
cfprVnicSanConnPolicyPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnPolicy:policyLevel
managed object property"
::= { cfprVnicSanConnPolicyEntry 8 }
cfprVnicSanConnPolicyPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnPolicy:policyOwner
managed object property"
::= { cfprVnicSanConnPolicyEntry 9 }
cfprVnicSanConnTemplTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicSanConnTemplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl managed object table"
::= { cfprVnicObjects 62 }
cfprVnicSanConnTemplEntry OBJECT-TYPE
SYNTAX CfprVnicSanConnTemplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicSanConnTemplTable table."
INDEX { cfprVnicSanConnTemplInstanceId }
::= { cfprVnicSanConnTemplTable 1 }
CfprVnicSanConnTemplEntry ::= SEQUENCE {
cfprVnicSanConnTemplInstanceId CfprManagedObjectId,
cfprVnicSanConnTemplDn CfprManagedObjectDn,
cfprVnicSanConnTemplRn SnmpAdminString,
cfprVnicSanConnTemplDescr SnmpAdminString,
cfprVnicSanConnTemplIdentPoolName SnmpAdminString,
cfprVnicSanConnTemplIntId SnmpAdminString,
cfprVnicSanConnTemplMaxDataFieldSize Gauge32,
cfprVnicSanConnTemplName SnmpAdminString,
cfprVnicSanConnTemplNwCtrlPolicyName SnmpAdminString,
cfprVnicSanConnTemplOperIdentPoolName SnmpAdminString,
cfprVnicSanConnTemplOperQosPolicyName SnmpAdminString,
cfprVnicSanConnTemplOperStatsPolicyName SnmpAdminString,
cfprVnicSanConnTemplPinToGroupName SnmpAdminString,
cfprVnicSanConnTemplPolicyLevel Gauge32,
cfprVnicSanConnTemplPolicyOwner CfprPolicyPolicyOwner,
cfprVnicSanConnTemplQosPolicyName SnmpAdminString,
cfprVnicSanConnTemplStatsPolicyName SnmpAdminString,
cfprVnicSanConnTemplSwitchId CfprNetworkSwitchId,
cfprVnicSanConnTemplTarget CfprVnicSanConnTemplTarget,
cfprVnicSanConnTemplTemplType CfprVnicTemplateType
}
cfprVnicSanConnTemplInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicSanConnTemplEntry 1 }
cfprVnicSanConnTemplDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:dn managed object property"
::= { cfprVnicSanConnTemplEntry 2 }
cfprVnicSanConnTemplRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:rn managed object property"
::= { cfprVnicSanConnTemplEntry 3 }
cfprVnicSanConnTemplDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:descr managed object property"
::= { cfprVnicSanConnTemplEntry 4 }
cfprVnicSanConnTemplIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:identPoolName
managed object property"
::= { cfprVnicSanConnTemplEntry 5 }
cfprVnicSanConnTemplIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:intId managed object property"
::= { cfprVnicSanConnTemplEntry 6 }
cfprVnicSanConnTemplMaxDataFieldSize OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:maxDataFieldSize
managed object property"
::= { cfprVnicSanConnTemplEntry 7 }
cfprVnicSanConnTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:name managed object property"
::= { cfprVnicSanConnTemplEntry 8 }
cfprVnicSanConnTemplNwCtrlPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:nwCtrlPolicyName
managed object property"
::= { cfprVnicSanConnTemplEntry 9 }
cfprVnicSanConnTemplOperIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:operIdentPoolName
managed object property"
::= { cfprVnicSanConnTemplEntry 10 }
cfprVnicSanConnTemplOperQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:operQosPolicyName
managed object property"
::= { cfprVnicSanConnTemplEntry 11 }
cfprVnicSanConnTemplOperStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:operStatsPolicyName
managed object property"
::= { cfprVnicSanConnTemplEntry 12 }
cfprVnicSanConnTemplPinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:pinToGroupName
managed object property"
::= { cfprVnicSanConnTemplEntry 13 }
cfprVnicSanConnTemplPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:policyLevel
managed object property"
::= { cfprVnicSanConnTemplEntry 14 }
cfprVnicSanConnTemplPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:policyOwner
managed object property"
::= { cfprVnicSanConnTemplEntry 15 }
cfprVnicSanConnTemplQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:qosPolicyName
managed object property"
::= { cfprVnicSanConnTemplEntry 16 }
cfprVnicSanConnTemplStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:statsPolicyName
managed object property"
::= { cfprVnicSanConnTemplEntry 17 }
cfprVnicSanConnTemplSwitchId OBJECT-TYPE
SYNTAX CfprNetworkSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:switchId managed
object property"
::= { cfprVnicSanConnTemplEntry 18 }
cfprVnicSanConnTemplTarget OBJECT-TYPE
SYNTAX CfprVnicSanConnTemplTarget
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:target managed object property"
::= { cfprVnicSanConnTemplEntry 19 }
cfprVnicSanConnTemplTemplType OBJECT-TYPE
SYNTAX CfprVnicTemplateType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:SanConnTempl:templType managed
object property"
::= { cfprVnicSanConnTemplEntry 20 }
cfprVnicScsiTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicScsiEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi managed object table"
::= { cfprVnicObjects 63 }
cfprVnicScsiEntry OBJECT-TYPE
SYNTAX CfprVnicScsiEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicScsiTable table."
INDEX { cfprVnicScsiInstanceId }
::= { cfprVnicScsiTable 1 }
CfprVnicScsiEntry ::= SEQUENCE {
cfprVnicScsiInstanceId CfprManagedObjectId,
cfprVnicScsiDn CfprManagedObjectDn,
cfprVnicScsiRn SnmpAdminString,
cfprVnicScsiAdaptorProfileName SnmpAdminString,
cfprVnicScsiAdminHostPort CfprFabricHostPortId,
cfprVnicScsiAdminVcon SnmpAdminString,
cfprVnicScsiAppRole CfprVnicAppRole,
cfprVnicScsiBootDev CfprVnicVnicBootDev,
cfprVnicScsiConfigQualifier CfprVnicConfigIssues,
cfprVnicScsiConfigState CfprLsConfigState,
cfprVnicScsiEquipmentDn SnmpAdminString,
cfprVnicScsiIdentPoolName SnmpAdminString,
cfprVnicScsiInstType CfprVnicInstantiation,
cfprVnicScsiName SnmpAdminString,
cfprVnicScsiNwTemplName SnmpAdminString,
cfprVnicScsiOperHostPort CfprVnicVnicOperHostPort,
cfprVnicScsiOperOrder Gauge32,
cfprVnicScsiOperSpeed Gauge32,
cfprVnicScsiOperStatsPolicyName SnmpAdminString,
cfprVnicScsiOperVcon SnmpAdminString,
cfprVnicScsiOrder Gauge32,
cfprVnicScsiOwner CfprVnicConnectionOwner,
cfprVnicScsiPinToGroupName SnmpAdminString,
cfprVnicScsiQosPolicyName SnmpAdminString,
cfprVnicScsiStatsPolicyName SnmpAdminString,
cfprVnicScsiSwitchId CfprNetworkSwitchId,
cfprVnicScsiType CfprVnicScsiType
}
cfprVnicScsiInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicScsiEntry 1 }
cfprVnicScsiDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:dn managed object property"
::= { cfprVnicScsiEntry 2 }
cfprVnicScsiRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:rn managed object property"
::= { cfprVnicScsiEntry 3 }
cfprVnicScsiAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:adaptorProfileName managed
object property"
::= { cfprVnicScsiEntry 4 }
cfprVnicScsiAdminHostPort OBJECT-TYPE
SYNTAX CfprFabricHostPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:adminHostPort managed object property"
::= { cfprVnicScsiEntry 5 }
cfprVnicScsiAdminVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:adminVcon managed object property"
::= { cfprVnicScsiEntry 6 }
cfprVnicScsiAppRole OBJECT-TYPE
SYNTAX CfprVnicAppRole
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:appRole managed object property"
::= { cfprVnicScsiEntry 7 }
cfprVnicScsiBootDev OBJECT-TYPE
SYNTAX CfprVnicVnicBootDev
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:bootDev managed object property"
::= { cfprVnicScsiEntry 8 }
cfprVnicScsiConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:configQualifier managed
object property"
::= { cfprVnicScsiEntry 9 }
cfprVnicScsiConfigState OBJECT-TYPE
SYNTAX CfprLsConfigState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:configState managed object property"
::= { cfprVnicScsiEntry 10 }
cfprVnicScsiEquipmentDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:equipmentDn managed object property"
::= { cfprVnicScsiEntry 11 }
cfprVnicScsiIdentPoolName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:identPoolName managed object property"
::= { cfprVnicScsiEntry 12 }
cfprVnicScsiInstType OBJECT-TYPE
SYNTAX CfprVnicInstantiation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:instType managed object property"
::= { cfprVnicScsiEntry 13 }
cfprVnicScsiName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:name managed object property"
::= { cfprVnicScsiEntry 14 }
cfprVnicScsiNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:nwTemplName managed object property"
::= { cfprVnicScsiEntry 15 }
cfprVnicScsiOperHostPort OBJECT-TYPE
SYNTAX CfprVnicVnicOperHostPort
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:operHostPort managed object property"
::= { cfprVnicScsiEntry 16 }
cfprVnicScsiOperOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:operOrder managed object property"
::= { cfprVnicScsiEntry 17 }
cfprVnicScsiOperSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:operSpeed managed object property"
::= { cfprVnicScsiEntry 18 }
cfprVnicScsiOperStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:operStatsPolicyName
managed object property"
::= { cfprVnicScsiEntry 19 }
cfprVnicScsiOperVcon OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:operVcon managed object property"
::= { cfprVnicScsiEntry 20 }
cfprVnicScsiOrder OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:order managed object property"
::= { cfprVnicScsiEntry 21 }
cfprVnicScsiOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:owner managed object property"
::= { cfprVnicScsiEntry 22 }
cfprVnicScsiPinToGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:pinToGroupName managed object property"
::= { cfprVnicScsiEntry 23 }
cfprVnicScsiQosPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:qosPolicyName managed object property"
::= { cfprVnicScsiEntry 24 }
cfprVnicScsiStatsPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:statsPolicyName managed
object property"
::= { cfprVnicScsiEntry 25 }
cfprVnicScsiSwitchId OBJECT-TYPE
SYNTAX CfprNetworkSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:switchId managed object property"
::= { cfprVnicScsiEntry 26 }
cfprVnicScsiType OBJECT-TYPE
SYNTAX CfprVnicScsiType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Scsi:type managed object property"
::= { cfprVnicScsiEntry 27 }
cfprVnicScsiIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicScsiIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf managed object table"
::= { cfprVnicObjects 64 }
cfprVnicScsiIfEntry OBJECT-TYPE
SYNTAX CfprVnicScsiIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicScsiIfTable table."
INDEX { cfprVnicScsiIfInstanceId }
::= { cfprVnicScsiIfTable 1 }
CfprVnicScsiIfEntry ::= SEQUENCE {
cfprVnicScsiIfInstanceId CfprManagedObjectId,
cfprVnicScsiIfDn CfprManagedObjectDn,
cfprVnicScsiIfRn SnmpAdminString,
cfprVnicScsiIfAddr Unsigned64,
cfprVnicScsiIfConfigQualifier CfprVnicConfigIssues,
cfprVnicScsiIfName SnmpAdminString,
cfprVnicScsiIfOperState CfprVnicIfOperState,
cfprVnicScsiIfOperVnetDn SnmpAdminString,
cfprVnicScsiIfOperVnetName SnmpAdminString,
cfprVnicScsiIfOwner CfprVnicConnectionOwner,
cfprVnicScsiIfPubNwId Gauge32,
cfprVnicScsiIfSharing CfprFabricVlanSharingType,
cfprVnicScsiIfSwitchId CfprNetworkSwitchId,
cfprVnicScsiIfType CfprVnicAScsiIfType,
cfprVnicScsiIfVnet Gauge32
}
cfprVnicScsiIfInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicScsiIfEntry 1 }
cfprVnicScsiIfDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:dn managed object property"
::= { cfprVnicScsiIfEntry 2 }
cfprVnicScsiIfRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:rn managed object property"
::= { cfprVnicScsiIfEntry 3 }
cfprVnicScsiIfAddr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:addr managed object property"
::= { cfprVnicScsiIfEntry 4 }
cfprVnicScsiIfConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:configQualifier managed
object property"
::= { cfprVnicScsiIfEntry 5 }
cfprVnicScsiIfName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:name managed object property"
::= { cfprVnicScsiIfEntry 6 }
cfprVnicScsiIfOperState OBJECT-TYPE
SYNTAX CfprVnicIfOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:operState managed object property"
::= { cfprVnicScsiIfEntry 7 }
cfprVnicScsiIfOperVnetDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:operVnetDn managed object property"
::= { cfprVnicScsiIfEntry 8 }
cfprVnicScsiIfOperVnetName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:operVnetName managed object property"
::= { cfprVnicScsiIfEntry 9 }
cfprVnicScsiIfOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:owner managed object property"
::= { cfprVnicScsiIfEntry 10 }
cfprVnicScsiIfPubNwId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:pubNwId managed object property"
::= { cfprVnicScsiIfEntry 11 }
cfprVnicScsiIfSharing OBJECT-TYPE
SYNTAX CfprFabricVlanSharingType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:sharing managed object property"
::= { cfprVnicScsiIfEntry 12 }
cfprVnicScsiIfSwitchId OBJECT-TYPE
SYNTAX CfprNetworkSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:switchId managed object property"
::= { cfprVnicScsiIfEntry 13 }
cfprVnicScsiIfType OBJECT-TYPE
SYNTAX CfprVnicAScsiIfType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:type managed object property"
::= { cfprVnicScsiIfEntry 14 }
cfprVnicScsiIfVnet OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:ScsiIf:vnet managed object property"
::= { cfprVnicScsiIfEntry 15 }
cfprVnicUsnicConPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicUsnicConPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicy managed object table"
::= { cfprVnicObjects 65 }
cfprVnicUsnicConPolicyEntry OBJECT-TYPE
SYNTAX CfprVnicUsnicConPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicUsnicConPolicyTable table."
INDEX { cfprVnicUsnicConPolicyInstanceId }
::= { cfprVnicUsnicConPolicyTable 1 }
CfprVnicUsnicConPolicyEntry ::= SEQUENCE {
cfprVnicUsnicConPolicyInstanceId CfprManagedObjectId,
cfprVnicUsnicConPolicyDn CfprManagedObjectDn,
cfprVnicUsnicConPolicyRn SnmpAdminString,
cfprVnicUsnicConPolicyAdaptorProfileName SnmpAdminString,
cfprVnicUsnicConPolicyDescr SnmpAdminString,
cfprVnicUsnicConPolicyIntId SnmpAdminString,
cfprVnicUsnicConPolicyName SnmpAdminString,
cfprVnicUsnicConPolicyPolicyLevel Gauge32,
cfprVnicUsnicConPolicyPolicyOwner CfprPolicyPolicyOwner,
cfprVnicUsnicConPolicyUsnicCount Gauge32
}
cfprVnicUsnicConPolicyInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicUsnicConPolicyEntry 1 }
cfprVnicUsnicConPolicyDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicy:dn managed object property"
::= { cfprVnicUsnicConPolicyEntry 2 }
cfprVnicUsnicConPolicyRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicy:rn managed object property"
::= { cfprVnicUsnicConPolicyEntry 3 }
cfprVnicUsnicConPolicyAdaptorProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicy:adaptorProfileName
managed object property"
::= { cfprVnicUsnicConPolicyEntry 4 }
cfprVnicUsnicConPolicyDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicy:descr managed
object property"
::= { cfprVnicUsnicConPolicyEntry 5 }
cfprVnicUsnicConPolicyIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicy:intId managed
object property"
::= { cfprVnicUsnicConPolicyEntry 6 }
cfprVnicUsnicConPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicy:name managed object property"
::= { cfprVnicUsnicConPolicyEntry 7 }
cfprVnicUsnicConPolicyPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicy:policyLevel
managed object property"
::= { cfprVnicUsnicConPolicyEntry 8 }
cfprVnicUsnicConPolicyPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicy:policyOwner
managed object property"
::= { cfprVnicUsnicConPolicyEntry 9 }
cfprVnicUsnicConPolicyUsnicCount OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicy:usnicCount
managed object property"
::= { cfprVnicUsnicConPolicyEntry 10 }
cfprVnicUsnicConPolicyRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicUsnicConPolicyRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicyRef managed object table"
::= { cfprVnicObjects 66 }
cfprVnicUsnicConPolicyRefEntry OBJECT-TYPE
SYNTAX CfprVnicUsnicConPolicyRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicUsnicConPolicyRefTable table."
INDEX { cfprVnicUsnicConPolicyRefInstanceId }
::= { cfprVnicUsnicConPolicyRefTable 1 }
CfprVnicUsnicConPolicyRefEntry ::= SEQUENCE {
cfprVnicUsnicConPolicyRefInstanceId CfprManagedObjectId,
cfprVnicUsnicConPolicyRefDn CfprManagedObjectDn,
cfprVnicUsnicConPolicyRefRn SnmpAdminString,
cfprVnicUsnicConPolicyRefConPolicyName SnmpAdminString,
cfprVnicUsnicConPolicyRefOperConPolicyName SnmpAdminString
}
cfprVnicUsnicConPolicyRefInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicUsnicConPolicyRefEntry 1 }
cfprVnicUsnicConPolicyRefDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicyRef:dn managed
object property"
::= { cfprVnicUsnicConPolicyRefEntry 2 }
cfprVnicUsnicConPolicyRefRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicyRef:rn managed
object property"
::= { cfprVnicUsnicConPolicyRefEntry 3 }
cfprVnicUsnicConPolicyRefConPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicyRef:conPolicyName
managed object property"
::= { cfprVnicUsnicConPolicyRefEntry 4 }
cfprVnicUsnicConPolicyRefOperConPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:UsnicConPolicyRef:operConPolicyName
managed object property"
::= { cfprVnicUsnicConPolicyRefEntry 5 }
cfprVnicVhbaBehPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicVhbaBehPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VhbaBehPolicy managed object table"
::= { cfprVnicObjects 67 }
cfprVnicVhbaBehPolicyEntry OBJECT-TYPE
SYNTAX CfprVnicVhbaBehPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicVhbaBehPolicyTable table."
INDEX { cfprVnicVhbaBehPolicyInstanceId }
::= { cfprVnicVhbaBehPolicyTable 1 }
CfprVnicVhbaBehPolicyEntry ::= SEQUENCE {
cfprVnicVhbaBehPolicyInstanceId CfprManagedObjectId,
cfprVnicVhbaBehPolicyDn CfprManagedObjectDn,
cfprVnicVhbaBehPolicyRn SnmpAdminString,
cfprVnicVhbaBehPolicyAction CfprVnicDefaultAction,
cfprVnicVhbaBehPolicyDescr SnmpAdminString,
cfprVnicVhbaBehPolicyIntId SnmpAdminString,
cfprVnicVhbaBehPolicyName SnmpAdminString,
cfprVnicVhbaBehPolicyNwTemplName SnmpAdminString,
cfprVnicVhbaBehPolicyPolicyLevel Gauge32,
cfprVnicVhbaBehPolicyPolicyOwner CfprPolicyPolicyOwner,
cfprVnicVhbaBehPolicyType CfprVnicVhbaBehPolicyType
}
cfprVnicVhbaBehPolicyInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicVhbaBehPolicyEntry 1 }
cfprVnicVhbaBehPolicyDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VhbaBehPolicy:dn managed object property"
::= { cfprVnicVhbaBehPolicyEntry 2 }
cfprVnicVhbaBehPolicyRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VhbaBehPolicy:rn managed object property"
::= { cfprVnicVhbaBehPolicyEntry 3 }
cfprVnicVhbaBehPolicyAction OBJECT-TYPE
SYNTAX CfprVnicDefaultAction
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VhbaBehPolicy:action managed
object property"
::= { cfprVnicVhbaBehPolicyEntry 4 }
cfprVnicVhbaBehPolicyDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VhbaBehPolicy:descr managed object property"
::= { cfprVnicVhbaBehPolicyEntry 5 }
cfprVnicVhbaBehPolicyIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VhbaBehPolicy:intId managed object property"
::= { cfprVnicVhbaBehPolicyEntry 6 }
cfprVnicVhbaBehPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VhbaBehPolicy:name managed object property"
::= { cfprVnicVhbaBehPolicyEntry 7 }
cfprVnicVhbaBehPolicyNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VhbaBehPolicy:nwTemplName
managed object property"
::= { cfprVnicVhbaBehPolicyEntry 8 }
cfprVnicVhbaBehPolicyPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VhbaBehPolicy:policyLevel
managed object property"
::= { cfprVnicVhbaBehPolicyEntry 9 }
cfprVnicVhbaBehPolicyPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VhbaBehPolicy:policyOwner
managed object property"
::= { cfprVnicVhbaBehPolicyEntry 10 }
cfprVnicVhbaBehPolicyType OBJECT-TYPE
SYNTAX CfprVnicVhbaBehPolicyType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VhbaBehPolicy:type managed object property"
::= { cfprVnicVhbaBehPolicyEntry 11 }
cfprVnicVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan managed object table"
::= { cfprVnicObjects 68 }
cfprVnicVlanEntry OBJECT-TYPE
SYNTAX CfprVnicVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicVlanTable table."
INDEX { cfprVnicVlanInstanceId }
::= { cfprVnicVlanTable 1 }
CfprVnicVlanEntry ::= SEQUENCE {
cfprVnicVlanInstanceId CfprManagedObjectId,
cfprVnicVlanDn CfprManagedObjectDn,
cfprVnicVlanRn SnmpAdminString,
cfprVnicVlanConfigQualifier CfprVnicConfigIssues,
cfprVnicVlanFltAggr Unsigned64,
cfprVnicVlanName SnmpAdminString,
cfprVnicVlanOperState CfprVnicIfOperState,
cfprVnicVlanOperVnetDn SnmpAdminString,
cfprVnicVlanOperVnetName SnmpAdminString,
cfprVnicVlanOwner CfprVnicConnectionOwner,
cfprVnicVlanPubNwId Gauge32,
cfprVnicVlanSharing CfprFabricVlanSharingType,
cfprVnicVlanSwitchId CfprNetworkSwitchId,
cfprVnicVlanType CfprVnicConnectionType,
cfprVnicVlanVlanName SnmpAdminString,
cfprVnicVlanVnet Gauge32
}
cfprVnicVlanInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicVlanEntry 1 }
cfprVnicVlanDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:dn managed object property"
::= { cfprVnicVlanEntry 2 }
cfprVnicVlanRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:rn managed object property"
::= { cfprVnicVlanEntry 3 }
cfprVnicVlanConfigQualifier OBJECT-TYPE
SYNTAX CfprVnicConfigIssues
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:configQualifier managed
object property"
::= { cfprVnicVlanEntry 4 }
cfprVnicVlanFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:fltAggr managed object property"
::= { cfprVnicVlanEntry 5 }
cfprVnicVlanName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:name managed object property"
::= { cfprVnicVlanEntry 6 }
cfprVnicVlanOperState OBJECT-TYPE
SYNTAX CfprVnicIfOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:operState managed object property"
::= { cfprVnicVlanEntry 7 }
cfprVnicVlanOperVnetDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:operVnetDn managed object property"
::= { cfprVnicVlanEntry 8 }
cfprVnicVlanOperVnetName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:operVnetName managed object property"
::= { cfprVnicVlanEntry 9 }
cfprVnicVlanOwner OBJECT-TYPE
SYNTAX CfprVnicConnectionOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:owner managed object property"
::= { cfprVnicVlanEntry 10 }
cfprVnicVlanPubNwId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:pubNwId managed object property"
::= { cfprVnicVlanEntry 11 }
cfprVnicVlanSharing OBJECT-TYPE
SYNTAX CfprFabricVlanSharingType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:sharing managed object property"
::= { cfprVnicVlanEntry 12 }
cfprVnicVlanSwitchId OBJECT-TYPE
SYNTAX CfprNetworkSwitchId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:switchId managed object property"
::= { cfprVnicVlanEntry 13 }
cfprVnicVlanType OBJECT-TYPE
SYNTAX CfprVnicConnectionType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:type managed object property"
::= { cfprVnicVlanEntry 14 }
cfprVnicVlanVlanName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:vlanName managed object property"
::= { cfprVnicVlanEntry 15 }
cfprVnicVlanVnet OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:Vlan:vnet managed object property"
::= { cfprVnicVlanEntry 16 }
cfprVnicVmqConPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicVmqConPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicy managed object table"
::= { cfprVnicObjects 69 }
cfprVnicVmqConPolicyEntry OBJECT-TYPE
SYNTAX CfprVnicVmqConPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicVmqConPolicyTable table."
INDEX { cfprVnicVmqConPolicyInstanceId }
::= { cfprVnicVmqConPolicyTable 1 }
CfprVnicVmqConPolicyEntry ::= SEQUENCE {
cfprVnicVmqConPolicyInstanceId CfprManagedObjectId,
cfprVnicVmqConPolicyDn CfprManagedObjectDn,
cfprVnicVmqConPolicyRn SnmpAdminString,
cfprVnicVmqConPolicyDescr SnmpAdminString,
cfprVnicVmqConPolicyIntId SnmpAdminString,
cfprVnicVmqConPolicyIntrCount Gauge32,
cfprVnicVmqConPolicyName SnmpAdminString,
cfprVnicVmqConPolicyPolicyLevel Gauge32,
cfprVnicVmqConPolicyPolicyOwner CfprPolicyPolicyOwner,
cfprVnicVmqConPolicyVmqCount Gauge32
}
cfprVnicVmqConPolicyInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicVmqConPolicyEntry 1 }
cfprVnicVmqConPolicyDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicy:dn managed object property"
::= { cfprVnicVmqConPolicyEntry 2 }
cfprVnicVmqConPolicyRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicy:rn managed object property"
::= { cfprVnicVmqConPolicyEntry 3 }
cfprVnicVmqConPolicyDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicy:descr managed object property"
::= { cfprVnicVmqConPolicyEntry 4 }
cfprVnicVmqConPolicyIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicy:intId managed object property"
::= { cfprVnicVmqConPolicyEntry 5 }
cfprVnicVmqConPolicyIntrCount OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicy:intrCount managed
object property"
::= { cfprVnicVmqConPolicyEntry 6 }
cfprVnicVmqConPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicy:name managed object property"
::= { cfprVnicVmqConPolicyEntry 7 }
cfprVnicVmqConPolicyPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicy:policyLevel
managed object property"
::= { cfprVnicVmqConPolicyEntry 8 }
cfprVnicVmqConPolicyPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicy:policyOwner
managed object property"
::= { cfprVnicVmqConPolicyEntry 9 }
cfprVnicVmqConPolicyVmqCount OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicy:vmqCount managed
object property"
::= { cfprVnicVmqConPolicyEntry 10 }
cfprVnicVmqConPolicyRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicVmqConPolicyRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicyRef managed object table"
::= { cfprVnicObjects 70 }
cfprVnicVmqConPolicyRefEntry OBJECT-TYPE
SYNTAX CfprVnicVmqConPolicyRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicVmqConPolicyRefTable table."
INDEX { cfprVnicVmqConPolicyRefInstanceId }
::= { cfprVnicVmqConPolicyRefTable 1 }
CfprVnicVmqConPolicyRefEntry ::= SEQUENCE {
cfprVnicVmqConPolicyRefInstanceId CfprManagedObjectId,
cfprVnicVmqConPolicyRefDn CfprManagedObjectDn,
cfprVnicVmqConPolicyRefRn SnmpAdminString,
cfprVnicVmqConPolicyRefConPolicyName SnmpAdminString,
cfprVnicVmqConPolicyRefOperConPolicyName SnmpAdminString
}
cfprVnicVmqConPolicyRefInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicVmqConPolicyRefEntry 1 }
cfprVnicVmqConPolicyRefDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicyRef:dn managed object property"
::= { cfprVnicVmqConPolicyRefEntry 2 }
cfprVnicVmqConPolicyRefRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicyRef:rn managed object property"
::= { cfprVnicVmqConPolicyRefEntry 3 }
cfprVnicVmqConPolicyRefConPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicyRef:conPolicyName
managed object property"
::= { cfprVnicVmqConPolicyRefEntry 4 }
cfprVnicVmqConPolicyRefOperConPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VmqConPolicyRef:operConPolicyName
managed object property"
::= { cfprVnicVmqConPolicyRefEntry 5 }
cfprVnicVnicBehPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicVnicBehPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VnicBehPolicy managed object table"
::= { cfprVnicObjects 71 }
cfprVnicVnicBehPolicyEntry OBJECT-TYPE
SYNTAX CfprVnicVnicBehPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicVnicBehPolicyTable table."
INDEX { cfprVnicVnicBehPolicyInstanceId }
::= { cfprVnicVnicBehPolicyTable 1 }
CfprVnicVnicBehPolicyEntry ::= SEQUENCE {
cfprVnicVnicBehPolicyInstanceId CfprManagedObjectId,
cfprVnicVnicBehPolicyDn CfprManagedObjectDn,
cfprVnicVnicBehPolicyRn SnmpAdminString,
cfprVnicVnicBehPolicyAction CfprVnicDefaultAction,
cfprVnicVnicBehPolicyDescr SnmpAdminString,
cfprVnicVnicBehPolicyIntId SnmpAdminString,
cfprVnicVnicBehPolicyName SnmpAdminString,
cfprVnicVnicBehPolicyNwTemplName SnmpAdminString,
cfprVnicVnicBehPolicyPolicyLevel Gauge32,
cfprVnicVnicBehPolicyPolicyOwner CfprPolicyPolicyOwner,
cfprVnicVnicBehPolicyType CfprVnicVnicBehPolicyType
}
cfprVnicVnicBehPolicyInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicVnicBehPolicyEntry 1 }
cfprVnicVnicBehPolicyDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VnicBehPolicy:dn managed object property"
::= { cfprVnicVnicBehPolicyEntry 2 }
cfprVnicVnicBehPolicyRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VnicBehPolicy:rn managed object property"
::= { cfprVnicVnicBehPolicyEntry 3 }
cfprVnicVnicBehPolicyAction OBJECT-TYPE
SYNTAX CfprVnicDefaultAction
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VnicBehPolicy:action managed
object property"
::= { cfprVnicVnicBehPolicyEntry 4 }
cfprVnicVnicBehPolicyDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VnicBehPolicy:descr managed object property"
::= { cfprVnicVnicBehPolicyEntry 5 }
cfprVnicVnicBehPolicyIntId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VnicBehPolicy:intId managed object property"
::= { cfprVnicVnicBehPolicyEntry 6 }
cfprVnicVnicBehPolicyName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VnicBehPolicy:name managed object property"
::= { cfprVnicVnicBehPolicyEntry 7 }
cfprVnicVnicBehPolicyNwTemplName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VnicBehPolicy:nwTemplName
managed object property"
::= { cfprVnicVnicBehPolicyEntry 8 }
cfprVnicVnicBehPolicyPolicyLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VnicBehPolicy:policyLevel
managed object property"
::= { cfprVnicVnicBehPolicyEntry 9 }
cfprVnicVnicBehPolicyPolicyOwner OBJECT-TYPE
SYNTAX CfprPolicyPolicyOwner
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VnicBehPolicy:policyOwner
managed object property"
::= { cfprVnicVnicBehPolicyEntry 10 }
cfprVnicVnicBehPolicyType OBJECT-TYPE
SYNTAX CfprVnicVnicBehPolicyType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:VnicBehPolicy:type managed object property"
::= { cfprVnicVnicBehPolicyEntry 11 }
cfprVnicWwnnHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicWwnnHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:WwnnHistory managed object table"
::= { cfprVnicObjects 72 }
cfprVnicWwnnHistoryEntry OBJECT-TYPE
SYNTAX CfprVnicWwnnHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicWwnnHistoryTable table."
INDEX { cfprVnicWwnnHistoryInstanceId }
::= { cfprVnicWwnnHistoryTable 1 }
CfprVnicWwnnHistoryEntry ::= SEQUENCE {
cfprVnicWwnnHistoryInstanceId CfprManagedObjectId,
cfprVnicWwnnHistoryDn CfprManagedObjectDn,
cfprVnicWwnnHistoryRn SnmpAdminString,
cfprVnicWwnnHistoryOldwwnn Unsigned64
}
cfprVnicWwnnHistoryInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicWwnnHistoryEntry 1 }
cfprVnicWwnnHistoryDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:WwnnHistory:dn managed object property"
::= { cfprVnicWwnnHistoryEntry 2 }
cfprVnicWwnnHistoryRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:WwnnHistory:rn managed object property"
::= { cfprVnicWwnnHistoryEntry 3 }
cfprVnicWwnnHistoryOldwwnn OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:WwnnHistory:oldwwnn managed object property"
::= { cfprVnicWwnnHistoryEntry 4 }
cfprVnicWwpnHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprVnicWwpnHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower vnic:WwpnHistory managed object table"
::= { cfprVnicObjects 73 }
cfprVnicWwpnHistoryEntry OBJECT-TYPE
SYNTAX CfprVnicWwpnHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprVnicWwpnHistoryTable table."
INDEX { cfprVnicWwpnHistoryInstanceId }
::= { cfprVnicWwpnHistoryTable 1 }
CfprVnicWwpnHistoryEntry ::= SEQUENCE {
cfprVnicWwpnHistoryInstanceId CfprManagedObjectId,
cfprVnicWwpnHistoryDn CfprManagedObjectDn,
cfprVnicWwpnHistoryRn SnmpAdminString,
cfprVnicWwpnHistoryOldaddr Unsigned64
}
cfprVnicWwpnHistoryInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprVnicWwpnHistoryEntry 1 }
cfprVnicWwpnHistoryDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:WwpnHistory:dn managed object property"
::= { cfprVnicWwpnHistoryEntry 2 }
cfprVnicWwpnHistoryRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:WwpnHistory:rn managed object property"
::= { cfprVnicWwpnHistoryEntry 3 }
cfprVnicWwpnHistoryOldaddr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower vnic:WwpnHistory:oldaddr managed object property"
::= { cfprVnicWwpnHistoryEntry 4 }
END