Observium_CE/mibs/cisco/CISCO-FIREPOWER-PCI-MIB

428 lines
14 KiB
Plaintext

-- *********************************************************************
-- CISCO-FIREPOWER-PCI-MIB.my
--
-- MIB representation of the Cisco Firepower
-- PCI management information model package
--
-- Created March 2020 by Charles Bullis
--
-- Copyright (c) 2005-2020 Cisco Systems, Inc. All rights reserved.
--
-- *********************************************************************
CISCO-FIREPOWER-PCI-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Counter32,
Gauge32,
TimeTicks,
Counter64,
Unsigned32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
RowPointer,
DateAndTime,
DisplayString,
MacAddress,
TimeInterval,
TimeStamp,
TruthValue
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
InetAddressIPv4,
InetAddressIPv6
FROM INET-ADDRESS-MIB
ciscoMgmt
FROM CISCO-SMI
CiscoNetworkAddress,
Unsigned64,
CiscoInetAddressMask,
CiscoAlarmSeverity,
TimeIntervalSec
FROM CISCO-TC
ciscoFirepowerMIBObjects,
CfprManagedObjectId,
CfprManagedObjectDn
FROM CISCO-FIREPOWER-MIB
CfprEquipmentDiscoveryState,
CfprEquipmentOperability,
CfprEquipmentPowerState,
CfprEquipmentPresence,
CfprEquipmentSensorThresholdStatus,
CfprPciEquipSlotId
FROM CISCO-FIREPOWER-TC-MIB;
cfprPciObjects MODULE-IDENTITY
LAST-UPDATED "202003100000Z"
ORGANIZATION "Cisco Systems Inc."
CONTACT-INFO
"Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: firepower-mibs@cisco.com"
DESCRIPTION
"MIB representation of the Cisco Firepower
PCI management information model package"
::= { ciscoFirepowerMIBObjects 60 }
cfprPciEquipSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprPciEquipSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot managed object table"
::= { cfprPciObjects 1 }
cfprPciEquipSlotEntry OBJECT-TYPE
SYNTAX CfprPciEquipSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprPciEquipSlotTable table."
INDEX { cfprPciEquipSlotInstanceId }
::= { cfprPciEquipSlotTable 1 }
CfprPciEquipSlotEntry ::= SEQUENCE {
cfprPciEquipSlotInstanceId CfprManagedObjectId,
cfprPciEquipSlotDn CfprManagedObjectDn,
cfprPciEquipSlotRn SnmpAdminString,
cfprPciEquipSlotControllerReported SnmpAdminString,
cfprPciEquipSlotDiscoveryState CfprEquipmentDiscoveryState,
cfprPciEquipSlotFltAggr Unsigned64,
cfprPciEquipSlotHostReported SnmpAdminString,
cfprPciEquipSlotId CfprPciEquipSlotId,
cfprPciEquipSlotMacLeft MacAddress,
cfprPciEquipSlotMacRight MacAddress,
cfprPciEquipSlotModel SnmpAdminString,
cfprPciEquipSlotRevision SnmpAdminString,
cfprPciEquipSlotSerial SnmpAdminString,
cfprPciEquipSlotSmbiosId Gauge32,
cfprPciEquipSlotVendor SnmpAdminString
}
cfprPciEquipSlotInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprPciEquipSlotEntry 1 }
cfprPciEquipSlotDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:dn managed object property"
::= { cfprPciEquipSlotEntry 2 }
cfprPciEquipSlotRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:rn managed object property"
::= { cfprPciEquipSlotEntry 3 }
cfprPciEquipSlotControllerReported OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:controllerReported
managed object property"
::= { cfprPciEquipSlotEntry 4 }
cfprPciEquipSlotDiscoveryState OBJECT-TYPE
SYNTAX CfprEquipmentDiscoveryState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:discoveryState managed
object property"
::= { cfprPciEquipSlotEntry 5 }
cfprPciEquipSlotFltAggr OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:fltAggr managed object property"
::= { cfprPciEquipSlotEntry 6 }
cfprPciEquipSlotHostReported OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:hostReported managed
object property"
::= { cfprPciEquipSlotEntry 7 }
cfprPciEquipSlotId OBJECT-TYPE
SYNTAX CfprPciEquipSlotId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:id managed object property"
::= { cfprPciEquipSlotEntry 8 }
cfprPciEquipSlotMacLeft OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:macLeft managed object property"
::= { cfprPciEquipSlotEntry 9 }
cfprPciEquipSlotMacRight OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:macRight managed object property"
::= { cfprPciEquipSlotEntry 10 }
cfprPciEquipSlotModel OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:model managed object property"
::= { cfprPciEquipSlotEntry 11 }
cfprPciEquipSlotRevision OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:revision managed object property"
::= { cfprPciEquipSlotEntry 12 }
cfprPciEquipSlotSerial OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:serial managed object property"
::= { cfprPciEquipSlotEntry 13 }
cfprPciEquipSlotSmbiosId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:smbiosId managed object property"
::= { cfprPciEquipSlotEntry 14 }
cfprPciEquipSlotVendor OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:EquipSlot:vendor managed object property"
::= { cfprPciEquipSlotEntry 15 }
cfprPciUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfprPciUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit managed object table"
::= { cfprPciObjects 2 }
cfprPciUnitEntry OBJECT-TYPE
SYNTAX CfprPciUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the cfprPciUnitTable table."
INDEX { cfprPciUnitInstanceId }
::= { cfprPciUnitTable 1 }
CfprPciUnitEntry ::= SEQUENCE {
cfprPciUnitInstanceId CfprManagedObjectId,
cfprPciUnitDn CfprManagedObjectDn,
cfprPciUnitRn SnmpAdminString,
cfprPciUnitId Gauge32,
cfprPciUnitLocationDn SnmpAdminString,
cfprPciUnitModel SnmpAdminString,
cfprPciUnitOperQualifierReason SnmpAdminString,
cfprPciUnitOperState CfprEquipmentOperability,
cfprPciUnitOperability CfprEquipmentOperability,
cfprPciUnitPciAddr SnmpAdminString,
cfprPciUnitPciSlot SnmpAdminString,
cfprPciUnitPerf CfprEquipmentSensorThresholdStatus,
cfprPciUnitPower CfprEquipmentPowerState,
cfprPciUnitPresence CfprEquipmentPresence,
cfprPciUnitRevision SnmpAdminString,
cfprPciUnitSerial SnmpAdminString,
cfprPciUnitThermal CfprEquipmentSensorThresholdStatus,
cfprPciUnitVendor SnmpAdminString,
cfprPciUnitVoltage CfprEquipmentSensorThresholdStatus
}
cfprPciUnitInstanceId OBJECT-TYPE
SYNTAX CfprManagedObjectId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Instance identifier of the managed object."
::= { cfprPciUnitEntry 1 }
cfprPciUnitDn OBJECT-TYPE
SYNTAX CfprManagedObjectDn
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:dn managed object property"
::= { cfprPciUnitEntry 2 }
cfprPciUnitRn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:rn managed object property"
::= { cfprPciUnitEntry 3 }
cfprPciUnitId OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:id managed object property"
::= { cfprPciUnitEntry 4 }
cfprPciUnitLocationDn OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:locationDn managed object property"
::= { cfprPciUnitEntry 5 }
cfprPciUnitModel OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:model managed object property"
::= { cfprPciUnitEntry 6 }
cfprPciUnitOperQualifierReason OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:operQualifierReason managed
object property"
::= { cfprPciUnitEntry 7 }
cfprPciUnitOperState OBJECT-TYPE
SYNTAX CfprEquipmentOperability
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:operState managed object property"
::= { cfprPciUnitEntry 8 }
cfprPciUnitOperability OBJECT-TYPE
SYNTAX CfprEquipmentOperability
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:operability managed object property"
::= { cfprPciUnitEntry 9 }
cfprPciUnitPciAddr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:pciAddr managed object property"
::= { cfprPciUnitEntry 10 }
cfprPciUnitPciSlot OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:pciSlot managed object property"
::= { cfprPciUnitEntry 11 }
cfprPciUnitPerf OBJECT-TYPE
SYNTAX CfprEquipmentSensorThresholdStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:perf managed object property"
::= { cfprPciUnitEntry 12 }
cfprPciUnitPower OBJECT-TYPE
SYNTAX CfprEquipmentPowerState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:power managed object property"
::= { cfprPciUnitEntry 13 }
cfprPciUnitPresence OBJECT-TYPE
SYNTAX CfprEquipmentPresence
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:presence managed object property"
::= { cfprPciUnitEntry 14 }
cfprPciUnitRevision OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:revision managed object property"
::= { cfprPciUnitEntry 15 }
cfprPciUnitSerial OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:serial managed object property"
::= { cfprPciUnitEntry 16 }
cfprPciUnitThermal OBJECT-TYPE
SYNTAX CfprEquipmentSensorThresholdStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:thermal managed object property"
::= { cfprPciUnitEntry 17 }
cfprPciUnitVendor OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:vendor managed object property"
::= { cfprPciUnitEntry 18 }
cfprPciUnitVoltage OBJECT-TYPE
SYNTAX CfprEquipmentSensorThresholdStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cisco Firepower pci:Unit:voltage managed object property"
::= { cfprPciUnitEntry 19 }
END