Observium_CE/mibs/cisco/CISCO-DMN-DSG-PROTOCOLS-MIB

173 lines
4.6 KiB
Plaintext

--*****************************************************************
-- CISCO_DMN_DSG_Protocols.mib: MIB file for protocol settings.
--
-- February 2012, Aaron Curtin
--
-- Copyright (c) 2012 by Cisco Systems, Inc. All rights reserved.
--*****************************************************************
CISCO-DMN-DSG-PROTOCOLS-MIB
DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE,
MODULE-IDENTITY, Counter32
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
ciscoDSGUtilities
FROM CISCO-DMN-DSG-ROOT-MIB;
ciscoDSGProtocols MODULE-IDENTITY
LAST-UPDATED "201307101903Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Cisco Systems, Inc.
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553 NETS
E-mail: cs-ipsla@cisco.com"
DESCRIPTION "Cisco Routing MIB."
REVISION "201307101903Z"
DESCRIPTION "V01.00.01 2013-07-10
Replace DTX with Syslog."
REVISION "201203070730Z"
DESCRIPTION "V01.00.00 2012-03-07
Initial Version."
::= { ciscoDSGUtilities 39 }
--**************************************
-- Protocols
--**************************************
protocolsCtrlTelnet OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select whether to allow Telnet connections or not"
::= { ciscoDSGProtocols 1 }
protocolsCtrlSSH OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select whether to allow secure shell connections or not."
::= { ciscoDSGProtocols 2 }
protocolsCtrlHTTP OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
secure(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select whether to allow web connections or not and choose
secure or unsecure mode."
::= { ciscoDSGProtocols 3 }
protocolsCtrlSNMP OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select whether to allow SNMP connections or not."
::= { ciscoDSGProtocols 5 }
protocolsCtrlRIP OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select whether to allow RIPv2 protocol or not."
::= { ciscoDSGProtocols 6 }
protocolsCtrlMPE OBJECT-TYPE
SYNTAX INTEGER {
fwdNone(1),
fwdAll(2),
fwdFiltered(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select whether to allow MPE protocol or not and select a mode."
::= { ciscoDSGProtocols 7 }
protocolsCtrlIGMP OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
v3(2),
v2(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select whether to allow IGMP protocol or not."
::= { ciscoDSGProtocols 8 }
protocolslTimeoutsIdleSessonGlobal OBJECT-TYPE
SYNTAX INTEGER (0..1209600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of seconds after which an idle session will timeout.
Enter 0 to never timeout. Minimum timeout is 30 seconds."
::= { ciscoDSGProtocols 9 }
protocolsCtrlSyslog OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
legacy(2),
syslogTcp(3),
syslogUdp(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select whether to allow Syslog and select a mode."
::= { ciscoDSGProtocols 10 }
protocolsCtrlSyslogCfgIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Syslog server entry IP Address."
::= { ciscoDSGProtocols 11 }
protocolsCtrlSyslogCfgPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Syslog server entry port number."
::= { ciscoDSGProtocols 12 }
END