-- WWP-PING-MIB.my
--
--
WWP-PING-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, Integer32, Counter32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
TruthValue, TEXTUAL-CONVENTION
FROM SNMPv2-TC
wwpModules
FROM WWP-SMI;
wwpPingMIB MODULE-IDENTITY
LAST-UPDATED "200107031257Z"
ORGANIZATION
"Organization."
CONTACT-INFO
" Mib Meister
Postal: World Wide Packets
P.O. Box 950
Veradale, WA 99037
USA
Phone: +1 509 242 9000
Email: mib.meister@worldwidepackets.com"
DESCRIPTION
"The MIB for WWP Ping"
REVISION "200107031257Z"
DESCRIPTION
"Initial Creation"
::= { wwpModules 21 }
--
-- Textual conventions
--
PingFailCause ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Description."
SYNTAX INTEGER
{
unknownHost(1),
socketError(2),
bindError(3),
connectError(4),
missingHost(5),
asyncError(6),
nonBlockError(7),
mcastError(8),
ttlError(9),
mcastTtlError(10),
outputError(11),
unreachableError(12),
isAlive(13),
txRx(14),
commandCompleted(15),
noStatus(16),
sendRecvMismatch(17)
}
PingState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Description."
SYNTAX INTEGER
{
idle(1),
pinging(2),
pingComplete(3),
failed(4)
}
--
-- Node definitions
--
wwpPingMIBObjects OBJECT IDENTIFIER ::= { wwpPingMIB 1 }
wwpPingDelay OBJECT-TYPE
SYNTAX Integer32 (0..100000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the minimum amount of time to wait
before sending the next packet in a sequence after receiving a
response or declaring a timeout for a previous packet."
::= { wwpPingMIBObjects 1 }
wwpPingPacketSize OBJECT-TYPE
SYNTAX Integer32 (1..1464)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The size of the ping packets to send to the target."
DEFVAL { 56 }
::= { wwpPingMIBObjects 2 }
wwpPingActivate OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ping can be activated by setting this object to true.
Once the ping operation is completed , the object is
set to 'false'. This object can be set to 'false'
by the Management Station to stop the ping."
::= { wwpPingMIBObjects 3 }
wwpPingAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address of the device to be pinged. The default
value should be of the loopback address."
::= { wwpPingMIBObjects 4 }
wwpPingPacketCount OBJECT-TYPE
SYNTAX Integer32 (0..100000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of icmp requests to send to the target."
::= { wwpPingMIBObjects 5 }
wwpPingPacketTimeout OBJECT-TYPE
SYNTAX Integer32 (0..100000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the amount of time to wait for a response to a
transmitted packet before declaring the packet 'dropped'."
::= { wwpPingMIBObjects 6 }
wwpPingSentPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ping packets that have been sent to the target."
::= { wwpPingMIBObjects 8 }
wwpPingReceivedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ping packets that have been reveived from the target."
::= { wwpPingMIBObjects 9 }
wwpPingFailCause OBJECT-TYPE
SYNTAX PingFailCause
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the ping."
::= { wwpPingMIBObjects 13 }
wwpPingState OBJECT-TYPE
SYNTAX PingState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the ping process.The state be pinging, idle,
complete or failed."
DEFVAL { idle }
::= { wwpPingMIBObjects 15 }
wwpPingUntilStopped OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"setting this object to true prior to wwpPingActivate will
cause the device to ping the specified host until
wwpPingActivate is set to false. The object can't be
modified once the ping is active. The object returns to
'false' once the ping is halted."
DEFVAL { false }
::= { wwpPingMIBObjects 16 }
END
--
-- WWP-PING-MIB.my
--