CAMBIUM-NETWORKS-RPS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
|
|
Unsigned32, Integer32, Counter32, enterprises
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
ifIndex
|
|
FROM IF-MIB
|
|
RowStatus, TruthValue
|
|
FROM SNMPv2-TC;
|
|
|
|
cnRPSMib MODULE-IDENTITY
|
|
LAST-UPDATED "202209082000Z" -- September 08, 2022
|
|
ORGANIZATION "Cambium Networks, Inc."
|
|
CONTACT-INFO "cambiumnetworks.com"
|
|
DESCRIPTION
|
|
"This MIB module contains objects related to the
|
|
Removable Power Supply support."
|
|
|
|
REVISION "202209082000Z" -- September 08, 2022
|
|
DESCRIPTION "Ver 2: Add cnRPSCurrentInputVoltage"
|
|
REVISION "202007030000Z" -- July 03, 2020
|
|
DESCRIPTION "Ver 1: Initial version."
|
|
|
|
::= { enterprises 17713 24 6 }
|
|
|
|
--
|
|
-- Removable Power Supply attributes
|
|
--
|
|
|
|
cnRPSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CnRPSTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RPS entry"
|
|
|
|
::= { cnRPSMib 1 }
|
|
|
|
cnRPSTableEntry OBJECT-TYPE
|
|
SYNTAX CnRPSTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port-specific data related to the transceivers"
|
|
|
|
INDEX { cnRPSIndex }
|
|
::= { cnRPSTable 1 }
|
|
|
|
CnRPSTableEntry ::= SEQUENCE {
|
|
cnRPSIndex Integer32,
|
|
cnRPSMaximumVoltage Integer32,
|
|
cnRPSMaximumCurrent Integer32,
|
|
cnRPSMaximumWatts Integer32,
|
|
cnRPSStatus INTEGER,
|
|
cnRPSCurrentInputVoltage Integer32
|
|
}
|
|
|
|
cnRPSIndex OBJECT-TYPE
|
|
SYNTAX Integer32(1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RPS index identifier attribute"
|
|
|
|
::= { cnRPSTableEntry 1 }
|
|
|
|
cnRPSMaximumVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum voltage of power supply."
|
|
|
|
::= { cnRPSTableEntry 2 }
|
|
|
|
cnRPSMaximumCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "amps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum current of power supply."
|
|
|
|
::= { cnRPSTableEntry 3 }
|
|
|
|
cnRPSMaximumWatts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum watts of power supply."
|
|
|
|
::= { cnRPSTableEntry 4 }
|
|
|
|
cnRPSStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
ok(1),
|
|
error(2),
|
|
notpresent(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of power supply."
|
|
|
|
::= { cnRPSTableEntry 5 }
|
|
|
|
cnRPSCurrentInputVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current input voltage applied to the power supply."
|
|
|
|
::= { cnRPSTableEntry 6 }
|
|
|
|
cnRPSTrapMsg NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cnRPSMaximumWatts,
|
|
cnRPSStatus,
|
|
cnRPSIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent out whenever a status change occurs on a power supply."
|
|
::= { cnRPSMib 2 }
|
|
|
|
END
|