-- Copyright (C) BTI Systems Inc. 2003-2010. All Rights Reserved.
--
-- The information contained herein is the property of BTI Systems Inc.
-- and is strictly confidential. Except as expressly authorized in
-- writing by BTI Systems Inc., the holder shall keep all information
-- contained herein confidential, shall disclose the information only
-- to its employees with a need to know, and shall protect the
-- information, in whole or in part, from disclosure and dissemination
-- to third parties with the same degree of care it uses to protect
-- its own confidential information, but with no less than reasonable
-- care. Except as expressly authorized in writing by BTI Systems Inc.,
-- the holder is granted no rights to use the information contained
-- herein.
--
-- Unpublished. All rights reserved under the copyright laws of
-- Canada.
--
-- OSS Integration
-- BTI Systems Inc. can provide customers with direct access to
-- network element SNMP MIBs for use for integration to OSS systems.
-- Customers must note the following caveats:
--
-- 1) Performance: The BTI Systems Inc. MIBS are performance tested for
-- use with the BTI Systems proNX 900 Node Controller and proNX 9000
-- Network Manager. Customers are responsible for conducting their
-- own testing to ensure that the BTI Systems Inc. NE interfaces meet
-- the needs of their proposed usage. BTI Systems Inc. makes no
-- guarantees that any proposed usage will meet customer requirements.
--
-- 2) Changes between releases: BTI Systems Inc. SNMP MIBs are subject
-- to change as support for new functionality is introduced. BTI
-- Systems Inc. strives to maintain backward compatibility of MIBs
-- across releases but this is not guaranteed and BTI Systems Inc.
-- reserves the right to deprecate or remove support for obsolete
-- MIB elements. OSS integrators must be careful not to rely on
-- functionality that is marked as deprecated as it may be unsupported
-- in a subsequent release. Customers that integrate directly to BTI
-- Systems Inc. MIBs are responsible for all OSS development and
-- integration testing that may arise from MIB changes between releases
-- of BTI Systems Inc. software.
--
------------------------------------------------------------------------
------------------------------------------------------------------------
BTI-7000-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, IpAddress, Gauge32,
Integer32, Unsigned32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DateAndTime, DisplayString, MacAddress, TruthValue,
RowStatus
FROM SNMPv2-TC
btiModules, bti7000
FROM BTI-MIB
FixedX10, FixedX100, ShelfType, ShelfConfigType, SlotType, CpType,
OaType, XcvrType, AmdType, AmdPortType, CondReportType, CondSeverity,
CondServiceAffecting, FiberType, WDMGrid, TimeZone,
AdminStatus, OperStatus, OperStatQlfr, HoursAndMinutes, PassivePortType,
XcvrProtocolType, PMIntervalType, PMValidity, BERType, ProtSwEvtType,
OcnType, StsnType, StmnType, VcnType, MediaRateType, DuplexModeType,
XCType, ProtectionStatusType, Unsigned64, PMMontype, UpgradeCompleteStage,
ProtSwOpCmd, InitializeCmd, OdunType, SwitchIdxType,
PvxL1PortType,PvxPortType,PowerFeedModeType, SyncSwEvtType,
NotifObjectType, NotifCodeType, AreaID, DesignatedRouterPriority,
InetAddressType, InetAddress, EnvNotifCodeType, MirrorConfigType, LoopbackType,
LldpChassisIdSubtype, LldpChassisId, LldpPortIdSubtype, LldpPortId
FROM BTI-TC-MIB;
bti7000Mib MODULE-IDENTITY
LAST-UPDATED "201210091200Z" -- Tuesday, October 09, 12:00:00 EST 2012
ORGANIZATION "BTI Systems Inc."
CONTACT-INFO "Technical Support
BTI Systems Inc.
200-1000 Innovation Drive
Kanata, Ontario, Canada, K2K 3E7
(613) 287-1700
support@btisystems.com"
DESCRIPTION "The external MIB definitions for the BTI 7000 series
products."
REVISION "201210091200Z" -- Tuesday, October 09, 12:00:00 EST 2012
DESCRIPTION "MIB Updates for BTI 7000 Rel 10.3.0:
- added ethIntfLldpAdminStatus"
REVISION "201208291200Z" -- Wednesday, August 29, 12:00:00 EST 2012
DESCRIPTION "MIB Updates for BTI 7000 Rel 10.2.0:
- added missing import of LoopbackType"
REVISION "201202101200Z" -- Friday, February 10, 12:00:00 EST 2012
DESCRIPTION "MIB Updates for BTI 7000 Rel 9.2.0:
- neAutoDeProv object status changed to obsolete
- in support of Remote ID feature, added new objects oaRemoteId
xcvrRemoteId, passivePortRemoteId, ocnRemoteId, stmnRemoteId,
geRemoteId, feRemoteId, fcRemoteId, ethIntfRemoteId, briRemoteId
- added new xcvrLoopbackType object
- added new value oprTerminalLpbk to xcvrLpbkOpCmd object
- added new tl1LogTable and latestTl1LogNum object
- deprecated pvxL2IntfIngressFiltering field in pvxL2IntfTable
- added new objects pvxL2IntfBcastLimit, pvxL2IntfMcastLimit, and
pvxL2IntfDlfLimit
- cpDbApplyResultEvt trap status changed to obsolete
- added new traps xcvrLFCond and xcvrLFClear"
REVISION "201109261200Z" -- Monday, September 26, 12:00:00 EST 2011
DESCRIPTION "MIB Updates for BTI 7000 Rel 9.1.0:
- added opticalLayer branch for all dynamic optical layer
managament objects
- added slotInvDataTable
- expanded value range of cpShelfIdx and cpSlotIdx to
support provisioning of D40MD modules
- added cpDegradeCond and cpDegradeClear traps
- added tl1LogTable"
REVISION "201104261200Z" -- Tuesday, April 26, 12:00:00 EST 2011
DESCRIPTION "MIB Updates for BTI 7000 Rel 8.2.0:
- added eptree and evptree to pvxEthSrvcType to support
ETREE services
- added pvxSrvsUNIForwarding to PvxServiceUNIEntry to
support ETREE services
- added attributes to the PVXSwitchModule and PVXSwitchMember
tables to support stacking
- port numbering changes on multiple tables: Static Multicast,
Static Unicast, Multicast Group, MSTPXstTable
- added pvxLGMaxLinks to support Active/Standby LAG
- added service-Map to pvxClassMapType to support per-flow
services
- added pvxSrvcUNIServiceMap and pvxSrvcUNIFilterSequence
to support per-flow services
- added pvxSrvcUNIEFPSDEnabled to support EFPSD
- added new tables pvSLAMeasurementProfileTable,
pvxEServiceSlaCrntPMTable, pvxEServiceSlaHistPMTable,
pvxEServieSlaPMThresholdTable, pvxSLAThroughputTestTable,
pvxSLAMsmtInitiatorDBTable, and pvxSLAMsmtResponderDBTable
to support the Y.1731 SLA Measurement feature
- added trap pvxSrvcUNIEFPSDLocalEFPSDStateChangeEvent"
REVISION "201103281200Z" -- Monday, March 28, 12:00:00 EST 2011
DESCRIPTION "MIB Updates for BTI 7000 Rel 8.1.4:
- added support for sftp protocol for use with the software
upgrade and database backup/restore operations."
REVISION "201102251200Z" -- Friday, February 25, 12:00:00 EST 2011
DESCRIPTION "MIB Updates for BTI 7000 Rel 8.1.3:
- added two new traps for NTP. One for indicating timing
ref change and the other for when NTP updates the system
date/time."
REVISION "201009171200Z" -- Friday, September 17, 12:00:00 EST 2010
DESCRIPTION "MIB Updates for BTI 7000 Rel 8.1.1:
- added snmpTrapRcvTable for administration of configured
recipients of traps generated by the SNMP agent"
REVISION "201008061200Z" -- Friday, August 6, 12:00:00 EST 2010
DESCRIPTION "MIB Updates for BTI 7000 Rel 8.1.0:
- changed range of objects representing a slot number
to support new 7200 shelf which has 20 slots
- added neFPDetect object to control Pack Missing alarms
- changed status of shelfInvConfig, shelfProvConfig and
shelfDiscConfig objects and shelfConfigurationMismatchCond
and shelfConfigurationMismatchClear notifications to deprecated
- increased size range of vcgTimeSlotIndices string to
support longer list of indices
- added new UAS PM objects in SONET OC-n (ocn), SDH STM-N (stmn),
Gigabit Ethernet (ge), Fiber Channel (fc), ethernet Layer 1
(ethL1IF)
- added ospfGeneralTable, ospfIfTable, ospfLsdbTable and
ospfNbrTable tables for management of OSPF
- added slotInvCoolingUnitMismatchCond and
slotInvCoolingUnitMismatchClear notifications"
REVISION "201006181200Z" -- Friday, June 18, 12:00:00 EST 2010
DESCRIPTION "MIB Updates for BTI 7000 Rel 7.3.2:
- added envCondAttrTable for managing environmental alarms
- added all environmental alarm traps under
envCondNotifications branch"
REVISION "201002121200Z" -- Friday, February 12, 12:00:00 EST 2010
DESCRIPTION "MIB Updates for BTI 7000 Rel 7.3.0:
- added objects pluggableInvWavelengthMin,
pluggableInvWavelengthMax and pluggableInvWavelengthSpacing
in support of tuneable pluggables
- added ocn, stmn, and ols versions of
'WavelengthNotAchievable' traps
- added ocnTransparencyChannel and stsnTransparencyChannel
objects to support DCC configuration on Muxponders
- added values sdSdi through dvbAsi to SYNTAX of briProtocol
- modified range of the IntervalType index field of all
historical PM tables from 1..32 to 1..96 in accordance
with increased binning support
- added objects to support new BER and average BER PM stats
in transceiver (XCVR), SONET OC-n (ocn), SDH STM-N (stmn),
and ethernet Layer 1 (ethL1IF) curent and historical PM tables
- added objects to support 64-bit versions of NBITCR and NBYTCR
stats in transceiver (XCVR), SONET OC-n (ocn), SDH STM-N (stmn),
and ethernet Layer 1 (ethL1IF) current and historical PM tables
- added gcc0ConfigTable and ipExtInterfaceTable
- marked the applyRestore value of the DbBackupAndRestoreCmd
textual convention as obsolete
- added cpSynchronizationPrimRefBasicSSM and
cpSynchronizationSecRefBasicSSM objects to support
synchronization status messages
- added cpSynchronizationSwitchEvt trap
- added briTxLockingCond and briTxLockingClear traps
to notify of when Bit-rate-independent facilities on
the Muxponder are in the process of locking."
REVISION "200901191200Z" -- Friday, June 19, 12:00:00 EST 2009
DESCRIPTION "MIB Updates for BTI 7000 Rel 7.2.0:
- added all objects under ntpClient branch for management
of Network Time Protocol
- added ocnDCCTransparency and stmnDCCTransparency objects
- added values vc42v, sts1c6v and sts3c2v to vcgType object
- added odunTable table for management of ODU-N facilities
on Muxponder circuit packs
- added briTable table for management of Bit Rate
Independent facilities on Muxponder circuit packs
- replaced references to SwitchIdxType TC with an integer
range of 1..11
- added btiCrntPMTable and briHistPMTable for retrieval of
current and historical PMs on BRI facilities
- added condObjectType and condCodeType objects to all
condition Trap varbind lists, added evtDescription,
evtObjectType and evtCodeType objects to all event Trap
varbind lists, added actCondObjectType and actCondCodeType
objects to actCondTable, and added actAlarmObjectType and
actAlarmCodeType objects to actAlarmTable to support
enhanced event/alarm/condition information feature.
- added briLpbkOpTable for BRI facility loopback management
- added new objects pvxL2IntfIsUNI to pvxL2IntfTrustIncomingDscp
in pvxL2IntfTable
- changed DEFVAL value of pvxL2IntfType from cep to pnp
- added setErrorInfo objects for reporting of error information
in response to failed set requests
- added condNotifCtrlTable and eventNotifState objects for
management of configurable alarm severity feature
- added new PVX Ethernet Interface Traps olsLossOfFrameCond to
olsOTUTrailTraceMismatchClear
- added new set of Traps under odunCondNotifications branch
- added new set of Traps under briCondNotifications branch
- added new set of Traps under ntpcCondNotifications branch"
REVISION "200812191200Z" -- Friday, December 19, 12:00:00 EST 2008
DESCRIPTION "MIB Updates for BTI 7000 Rel 7.1.2:
- corrected OID for slotInvUpgradeStage, slotInvUpgradeResult,
and slotInvPackUSI objects
- corrected DEFVAL clause for shelfPowerFeedA, shelfPowerFeedB
- added new values to ocnLineMapping/stmnLineMapping objects
- changed SYNTAX of vcgTimeSlotIndices object
- added ethIntMACAddr object
- changed ethIntfLineMapping value of none to tenglan
- added ethL1IFCrntPMTable, ethL1IFHistPMTable, and
ethL1IFPMThresholdTable for performance management
of Ethernet Layer 1 interfaces on PVX cards
- corrected MAX-ACCESS of all protection entity objects
in XC tables to read-create
- replaced otunProtGrpTable and otunProtSwOpTable with
ocnProtGrpTable, stmnProtGrpTable, ocnProtSwOpTable and
stmnProtSwOpTable
- added ocnProtSwitchEvt and stmnProtSwitchEvt traps
- added ethL1IFStatusChangeEvt and ethL1IFTcaEvt traps
- removed all unused otun and odun related objects"
REVISION "200810101200Z" -- Friday, October 10, 12:00:00 EST 2008
DESCRIPTION "MIB Updates for BTI 7000 Rel 7.1.1:
- added shelfInvUSI, slotInvPackUSI, and pluggableInvUSI objects
- added shelfPowerFeedA, shelfPowerFeedB objects
- removed NBITCR, NBYTCR from PM Threshold tables for
XCVRx, OCn, and STMn
- added EthIntfTable and pvxL2IntfTable for management of
Ethernet Layer 1 and Layer 2 interfaces respectively on
PVX card
- added pvxL2IFCrntPMTable, pvxL2IFHistPMTable, and
pvxL2IFPMThresholdTable for performance management
of Ethernet Layer 2 interfaces on PVX cards
- added the condDescription varbind to all condition
raise and clear traps
- added varbinds to shelfInvPlugin, slotInvPlugin and
pluggableInvPlugin event traps to provide detailed
data for the newly plugged in inventory item
- added ocnOTNPayloadMismatchCond and stmnOTNPayloadMismatchCond
condition traps
- added new condition traps under ethPortCondNotifications
and pvxL2PortCondNotifications OID branches"
REVISION "200805301200Z" -- Friday, May 30, 12:00:00 EST 2008
DESCRIPTION "MIB Updates for BTI 7000 Rel 7.1.0:
- replaced references to Netstender with BTI 7000
- added SDBERTh and Trace-related objects to xcvrTable
- added initialization objects for all PM value objects
- added TOHTransparency and LineMapping objects to ocnTable
and stmnTable
- added GFPMode and FlowControl objects to geTable
- modified vcgTable to allow creation of row entries
- added fcTable for Fiber Channel facilities on MXP cards
- added odunTable to support Traps on MXP cards
- added SUPPLY2, and OTU PMs to XCVR PM Tables
- added SONET Line layer, OTU, and FEC PMs to OC-N PM Tables
- added SDH MS layer, OTU, and FEC PMs to STM-N PM Tables
- added additional Layer 2 PMs to GE PM Tables
- added Fiber Channel PM Tables
- added several new Traps for TPR and 10GMXP packs"
REVISION "200709141200Z" -- Tuesday, September 18, 12:00:00 EST 2007
DESCRIPTION "MIB Updates for Netstender Rel 6.2.0: Completion of SNMP
coverage for all cards including all Wavelength Conversion,
2.5G Muxponder and AMD circuit packs. Addition of full
management support including Muxponder facilities, protocol
PMs, synchronization management, and database change messages.
New and expanded tables and other objects include:
- amdTable
- ocnTable
- stsnTable
- stmnTable
- vcnTable
- geTable
- feTable
- vcgTable
- serialTable
- xcvrCrntPMTable
- xcvrHistPMTable
- xcvrPMThresholdTable
- amdCrntPMTable
- amdHistPMTable
- ocnCrntPMTable
- ocnHistPMTable
- ocnPMThresholdTable
- stsnCrntPMTable
- stsnHistPMTable
- stsnPMThresholdByPortTable
- stmnCrntPMTable
- stmnHistPMTable
- stmnPMThresholdTable
- vcnCrntPMTable
- vcnHistPMTable
- vcnPMThresholdByPortTable
- geCrntPMTable
- geHistPMTable
- gePMThresholdTable
- vcgXCTable
- ocnLpbkOpTable
- stsnProtSwOpTable
- stmnLpbkOpTable
- vcnProtSwOpTable
- geLpbkOpTable
- cpSynchronizationTable
- networkNeighborTable
- Threshold crossing alert notifications and supporting
objects
- Database change messages and supporting objects"
REVISION "200707161200Z" -- Monday, July 16, 12:00:00 EST 2007
DESCRIPTION "MIB updates for Netstender Rel. 6.1: Added tables and traps in
support of new 2.5G Muxponder card.
- ocnTable, stsnTable, stmnTable, vcnTable, geTable
- stsnProtSwitchEvt, vcnProtSwitchEvt
- all condition notifications under ocnCondNotifications,
stsnCondNotifications, stmnCondNotifications,
vcnCondNotifications, geCondNotifications
- shelfInvAssemblyPEC object marked obsolete"
REVISION "200703091200Z" -- Friday, March 9, 12:00:00 EST 2007
DESCRIPTION "MIB Updates for Netstender Rel 5.1.1: Addition of full SNMP
support for management of inventory, equipment, optical
amplifiers, 2.5G wavelength conversion transceivers and
passive cards. New and expanded tables and other objects
include:
- networkElement group
- shelfInvTable
- slotInvTable
- pluggableInvTable
- shelfTable
- cpTable
- oaTable
- xcvrTable
- passivePortTable
- oscTable
- netMgmtTable
- oaCrntPMTable
- oaHistPMTable
- xcvrCrntPMTable
- xcvrHistPMTable
- xcvrXCTable
- xcvrProtGrpTable
- commitESOpTable
- cpRestartOpTable
- oaOOBRSDOpTable
- xcvrLpbkOpTable
- xcvrProtSwOpTable
- dataCommsPingTable
- addition of several Traps and supporting objects under
eventNotifications branch"
REVISION "200608251200Z" -- Friday, August 25, 12:00:00 EST 2006
DESCRIPTION "MIB Updates for Netstender Rel 5.1:
- generalized naming of SFP Inventory related objects and
notifications to allow for inclusion of XFPs as well as SFPs
- added Traps for Forced Switch, Lockout and Temp conditions
- added read-only support for Optical Amplifer Performance
Monitoring
- removed obsolete Red and Blue type OA notifications"
REVISION "200512051200Z" -- Monday, December 5, 12:00:00 EST 2005
DESCRIPTION "MIB Updates for Netstender Rel 4.1:
- changed actCondTable Index fields MAX-ACCESS to read-only
- added support for new multi-shelf, AMD, and XCVR Traps
- added TL1 IP Lockout, DspCommCond and Unsupported Pack traps
- marked some unused shelf-related Traps as obsolete"
REVISION "200507251200Z" -- Monday, July 25, 12:00:00 EST 2005
DESCRIPTION "MIB Updates for Netstender Rel 3.1.1:
- added support for TL1 User Lockout Traps
- added actCondTable to support retrieval of active conditions
on Netstender
- updated Contact Info in Module Identity"
REVISION "200501071200Z" -- Monday, February 7, 12:00:00 EST 2005
DESCRIPTION "MIB Updates for Netstender Rel 3.1:
- changed Shutdown terminology to Safety for OBR Traps
- added sfpInvTable, xcvrTable and new Traps for SFPs"
REVISION "200409231200Z" -- Thursday, September 23, 12:00:00 EST 2004
DESCRIPTION "MIB Updates for Netstender Rel 3.0:
- generalized object names to Netstender to support both
Netstender 2060 and Netstender 1030
- changed name of file from net2060.my to netstender.my
- changed name of MIB from NETSTENDER-2060-MIB to
NETSTENDER-MIB
- eliminated unnecessary textual conventions
- redefined several enumerations as textual conventions and
moved to BTI-TC-MIB
- corrected the descriptions for several objects"
REVISION "200409091434Z" -- Thursday, September 9, 14:34:00 EST 2004
DESCRIPTION "MIB Updates for Netstender 2060 Rel 2.2:
- added new Single Channel Booster Amp card types and OA type
- changed OIDs of SNMPv2c notifications to make them reverse
mapable: SNMPv2c -> SNMPv1 -> SNMPv2c
- defined new OA Back Reflection Shutdown notifications"
REVISION "200404142235Z" -- Wednesday, April 14, 22:35:00 EST 2004
DESCRIPTION "MIB Updates for Netstender 2060 Rel 2.1.3:
- added new supported card types and optical amplifier types
- added new Red and Blue type objects to OA Table
- defined new Red and Blue type OA notifications
- corrected the descriptions for several notifications"
REVISION "200312011200Z" -- Monday, December 1, 12:00:00 EST 2003
DESCRIPTION "The initial version of this MIB module, released with the
Netstender 2060 Rel 2.1 product."
::= { btiModules 3 }
objects OBJECT IDENTIFIER ::= { bti7000 1 }
networkElement OBJECT IDENTIFIER ::= { objects 1 }
inventory OBJECT IDENTIFIER ::= { objects 2 }
equipment OBJECT IDENTIFIER ::= { objects 3 }
facilities OBJECT IDENTIFIER ::= { objects 4 }
dataComms OBJECT IDENTIFIER ::= { objects 5 }
performance OBJECT IDENTIFIER ::= { objects 6 }
conditions OBJECT IDENTIFIER ::= { objects 7 }
administration OBJECT IDENTIFIER ::= { objects 8 }
connections OBJECT IDENTIFIER ::= { objects 9 }
protection OBJECT IDENTIFIER ::= { objects 10 }
operations OBJECT IDENTIFIER ::= { objects 11 }
synchronization OBJECT IDENTIFIER ::= { objects 12 }
topology OBJECT IDENTIFIER ::= { objects 13 }
pvxObjects OBJECT IDENTIFIER ::= { objects 14 }
miscellaneous OBJECT IDENTIFIER ::= { objects 15 }
opticalLayer OBJECT IDENTIFIER ::= { objects 16 }
pvxBridge OBJECT IDENTIFIER ::= { pvxObjects 1 }
pvxNotificationObjects OBJECT IDENTIFIER ::= { pvxObjects 4 }
mstpNotificationObjects OBJECT IDENTIFIER ::= { pvxNotificationObjects 1 }
notifications OBJECT IDENTIFIER ::= { bti7000 2 }
eventNotifications OBJECT IDENTIFIER ::= { notifications 1 }
conditionNotifications OBJECT IDENTIFIER ::= { notifications 2 }
dbChangeNotifications OBJECT IDENTIFIER ::= { notifications 3 }
notificationObjects OBJECT IDENTIFIER ::= { notifications 4 }
notificationControl OBJECT IDENTIFIER ::= { notifications 5 }
evtNotificationObjects OBJECT IDENTIFIER ::= { eventNotifications 1 }
neEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 2 }
shelfInvEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 3 }
slotInvEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 4 }
shelfEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 5 }
cpEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 6 }
oaEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 7 }
dataCommsEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 8 }
pluggableInvEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 9 }
xcvrEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 10 }
adminEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 11 }
amdEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 12 }
ocnEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 13 }
stsnEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 14 }
stmnEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 15 }
vcnEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 16 }
geEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 17 }
fcEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 18 }
ethPortEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 21 }
pvxL2EvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 22 }
mstpEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 23 }
briEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 24 }
cpSynchronizationEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 25 }
pvxESrvcBWPrflEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 26 }
pvxESrvcEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 27 }
pvxERPSSrvcNNIEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 28 }
pvxERPSSrvcEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 29 }
pvxSlaMsmtEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 30 }
ntpcEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 31 }
pvxSUniEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 32 }
olEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 33 }
pvxLldpEvtNotifications OBJECT IDENTIFIER ::= { eventNotifications 34 }
neCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 1 }
shelfInvCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 2 }
slotInvCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 3 }
shelfCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 4 }
cpCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 5 }
oaCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 6 }
dataCommsCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 7 }
pluggableInvCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 8 }
xcvrCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 9 }
adminCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 10 }
amdCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 11 }
ocnCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 12 }
stsnCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 13 }
stmnCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 14 }
vcnCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 15 }
geCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 16 }
fcCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 17 }
ethPortCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 20 }
pvxL2PortCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 21 }
mstpCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 22 }
lagCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 23 }
odunCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 24 }
briCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 25 }
ntpcCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 26 }
envCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 27 }
olCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 28 }
erpsCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 29 }
swMemberCondNotifications OBJECT IDENTIFIER ::= { conditionNotifications 30 }
condNotifCtrl OBJECT IDENTIFIER ::= { notificationControl 1 }
eventNotifCtrl OBJECT IDENTIFIER ::= { notificationControl 2 }
neOperations OBJECT IDENTIFIER ::= { operations 1 }
shelfInvOperations OBJECT IDENTIFIER ::= { operations 2 }
slotInvOperations OBJECT IDENTIFIER ::= { operations 3 }
shelfOperations OBJECT IDENTIFIER ::= { operations 4 }
cpOperations OBJECT IDENTIFIER ::= { operations 5 }
oaOperations OBJECT IDENTIFIER ::= { operations 6 }
dataCommsOperations OBJECT IDENTIFIER ::= { operations 7 }
pluggableInvOperations OBJECT IDENTIFIER ::= { operations 8 }
xcvrOperations OBJECT IDENTIFIER ::= { operations 9 }
adminOperations OBJECT IDENTIFIER ::= { operations 10 }
amdOperations OBJECT IDENTIFIER ::= { operations 11 }
ocnOperations OBJECT IDENTIFIER ::= { operations 12 }
stsnOperations OBJECT IDENTIFIER ::= { operations 13 }
stmnOperations OBJECT IDENTIFIER ::= { operations 14 }
vcnOperations OBJECT IDENTIFIER ::= { operations 15 }
geOperations OBJECT IDENTIFIER ::= { operations 16 }
fcOperations OBJECT IDENTIFIER ::= { operations 17 }
briOperations OBJECT IDENTIFIER ::= { operations 18 }
-----------------------------------------------------------------------
-----------------------------------------------------------------------
-- Managed object definitions.
-----------------------------------------------------------------------
-----------------------------------------------------------------------
-----------------------------------------------------------------------
-- Objects related to the Network Element as a whole
--
-- The following table lists the system level parameters supported by
-- BTI 7000 Series under the networkElement branch of the MIB. These
-- objects are in addition to those supported under the system group
-- of MIB-II.
-----------------------------------------------------------------------
neSWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The software version that is active on the NE currently."
::= { networkElement 1 }
neNum OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This is a unique network element number used to identify the
network element and to differentiate it from other NEs in the
management domain."
::= { networkElement 2 }
neSiteNum OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This is a network element site number used to uniquely
identify the site of the NE and to differentiate it from other
NE sites in the management domain."
::= { networkElement 3 }
neDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The current system date and time, without time zone
information."
::= { networkElement 4 }
neTimeZone OBJECT-TYPE
SYNTAX TimeZone
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The time zone in which the local time of this system is to be
reported. Typically, the time zone is the one in which the
system is physically located."
::= { networkElement 5 }
neAutoDST OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A setting that indicates whether the system time should be
updated automatically in accordance with the daylight savings
time characteristics of the current time zone."
::= { networkElement 6 }
neGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The default IP routing gateway for network management
interfaces on the node. If not specified, this object returns
a value of 0.0.0.0."
::= { networkElement 7 }
neSecGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The secondary IP routing gateway for network management
interfaces on the node. If not specified, this object returns
a value of 0.0.0.0."
::= { networkElement 8 }
neActiveGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP routing gateway that is currently active on the node.
If no gateway is active, this object returns a value of
0.0.0.0."
::= { networkElement 9 }
neAutoProv OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2),
autoEnabled (3),
autoProvOff (4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A setting that specifies if automatic provisioning of
equipment and facilities is enabled. If automatic provisioning
is enabled, this object indicates the default administration
status. The possible values include:
- enabled: Applicable entities are auto provisioned with the
initial state enabled.
- disabled: Applicable entities are auto provisioned with the
initial state disabled.
- autoEnabled: Applicable entities are auto provisioned and
placed into the auto-enabled state.
- autoProvOff: Auto provisioning is disabled."
::= { networkElement 10 }
neAutoDeProv OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-write
STATUS obsolete -- Obsolete as of release 8.2.0
DESCRIPTION "The time delay after a physical shelf or circuit pack is
removed from the NE before the provisioned entities that are
supported by the removed equipment are automatically
deprovisioned. If this object is set to a value of 000-00,
auto deprovisioning is disabled."
::= { networkElement 11 }
neAutoEnabledTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The system wide default auto-enable timer value. This timer
specifies a time delay after a provisioned facility in the
auto-enabled state is cleared of all alarms before the state
of the facility transitions to enabled. The default value can
be overridden by a facility-specific value that is specified
when the facility is either provisioned or edited in its
respective table."
::= { networkElement 12 }
ntpClient OBJECT IDENTIFIER ::= { networkElement 13 }
ntpClientPollingRate OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The polling rate for the NTP client to periodically fetch the
system time from the list of NTP servers configured."
::= { ntpClient 1 }
ntpClientAuthKey OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "The NTP authentication key ID, if authentication is required."
::= { ntpClient 2 }
ntpClientSyncState OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Status indicating if the node is in sync with one of the time
servers. Either Y or N."
::= { ntpClient 3 }
ntpClientStratum OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Specifies the stratum of the timer server the node in in sync
with."
::= { ntpClient 4 }
ntpClientRefIPAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of the time server the node is in sync with."
::= { ntpClient 5 }
ntpClientAssocTable OBJECT-TYPE
SYNTAX SEQUENCE OF NTPClientAssocEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of NTP servers to poll for the system time. The NTP
client then decides which is best clock source."
::= { ntpClient 6 }
ntpClientAssocEntry OBJECT-TYPE
SYNTAX NTPClientAssocEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The list entry for an NTP server."
INDEX { ntpClientAssocIdx }
::= { ntpClientAssocTable 1 }
NTPClientAssocEntry ::= SEQUENCE { ntpClientAssocIdx IpAddress,
ntpClientAssocRowStatus RowStatus }
ntpClientAssocIdx OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The IP address of the NTP server."
::= { ntpClientAssocEntry 1 }
ntpClientAssocRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
NTP client association table."
::= { ntpClientAssocEntry 100 }
ntpOldTimeAndDate OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The date and time of the system before the NTP client updated the
system clock."
::= { ntpClient 7 }
ntpNewTimeAndDate OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The new system date and time updated by the NTP client."
::= { ntpClient 8 }
ntpRefIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This the NTP server being used as the clock reference for the system."
::= { ntpClient 9 }
ntpRefStratum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This is the stratum of the NTP server being used as the clock
reference for the system."
::= { ntpClient 10 }
neFPDetect OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A setting that indicates whether the system should report pack
missing alarms."
::= { networkElement 14 }
neHTAutoShutdown OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A system wide setting that specifies whether the circuit pack
pack high temperature automatic shutdown (HTAS) is enabled.
When enabled, the circuit packs which support the HTAS feature
will be automatically powered down if the shutdown temperature
threshold for that circuit pack is exceeded.
There will be alarms indicating that the shutdown has occurred.
The default setting is enabled."
::= { networkElement 15 }
-----------------------------------------------------------------------
-- Objects related to the physical shelf inventory on the system
--
-- A listing of physically detected BTI 7000 Series shelves can be
-- retrieved from the shelfInvTable. The following table lists the
-- readable objects in each entry of the
-- shelfInvTable.
-----------------------------------------------------------------------
shelfInvTable OBJECT-TYPE
SYNTAX SEQUENCE OF ShelfInvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every physically detected
shelf on the NE. Each row contains a list of attributes that
pertain to a physical shelf."
::= { inventory 1 }
shelfInvEntry OBJECT-TYPE
SYNTAX ShelfInvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the shelf inventory table."
INDEX { shelfInvIdx }
::= { shelfInvTable 1 }
ShelfInvEntry ::= SEQUENCE { shelfInvIdx INTEGER,
shelfInvExpectedNEName DisplayString,
shelfInvExpectedIPAddress DisplayString,
shelfInvExpectedShelfNum INTEGER,
shelfInvExpectedMSISerialNum DisplayString,
shelfInvDiscoveredNEName DisplayString,
shelfInvDiscoveredIPAddress DisplayString,
shelfInvDiscoveredShelfNum INTEGER,
shelfInvDiscoveredMSISerialNum DisplayString,
shelfInvType ShelfType,
shelfInvShortName DisplayString,
shelfInvName DisplayString,
shelfInvChassisPEC DisplayString,
shelfInvChassisCLEI DisplayString,
shelfInvAssemblyPEC DisplayString,
shelfInvRev INTEGER,
shelfInvConfig ShelfConfigType,
shelfInvUSI DisplayString,
shelfInvSerialNum DisplayString,
shelfInvMfgDate DisplayString,
shelfInvMfgLoc DisplayString,
shelfInvTestDate DisplayString,
shelfInvTestLoc DisplayString}
shelfInvIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf. It is set to 1 for the main shelf,
otherwise the object is based on the expansion shelf port on
which the shelf is detected, and the number of hops from the
main shelf."
::= { shelfInvEntry 1 }
shelfInvExpectedNEName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The NE name expected by the main shelf to be reported by the
expansion shelf as the name of the NE to which it belongs."
::= { shelfInvEntry 2 }
shelfInvExpectedIPAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The string representation of the NE NMS IP address that is
expected by the main shelf to be reported by the expansion
shelf as the IP address of the NE to which it belongs."
::= { shelfInvEntry 3 }
shelfInvExpectedShelfNum OBJECT-TYPE
SYNTAX INTEGER (11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the expansion shelf that is expected by the main
shelf to be reported by the attached shelf."
::= { shelfInvEntry 4 }
shelfInvExpectedMSISerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The serial number of the Main Shelf Interface circuit pack
that is expected by the main shelf to be reported by the
expansion shelf as the MSI serial number of the NE main shelf
to which it belongs."
::= { shelfInvEntry 5 }
shelfInvDiscoveredNEName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The actual NE name reported by the expansion shelf as the name
of the NE to which it belongs."
::= { shelfInvEntry 6 }
shelfInvDiscoveredIPAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The string representation of the actual NE NMS IP address
reported by the expansion shelf as the IP address of the NE to
which it belongs."
::= { shelfInvEntry 7 }
shelfInvDiscoveredShelfNum OBJECT-TYPE
SYNTAX INTEGER (11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The actual number of the expansion shelf reported by the
attached shelf."
::= { shelfInvEntry 8 }
shelfInvDiscoveredMSISerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The actual serial number of the Main Shelf Interface circuit
pack reported by the expansion shelf as the MSI serial number
of the NE main shelf to which it belongs."
::= { shelfInvEntry 9 }
shelfInvType OBJECT-TYPE
SYNTAX ShelfType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if the shelf functions as a main shelf or an
expansion shelf."
::= { shelfInvEntry 10 }
shelfInvShortName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A concise representation of the shelf brand name."
::= { shelfInvEntry 11 }
shelfInvName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The full representation of the shelf brand name."
::= { shelfInvEntry 12 }
shelfInvChassisPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A string representation of the Product Equipment Code for the
shelf chassis alone."
::= { shelfInvEntry 13 }
shelfInvChassisCLEI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A string representation of the Telcordia Common Language
Equipment Identifier for the shelf chassis alone."
::= { shelfInvEntry 14 }
shelfInvAssemblyPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "A string representation of the Product Equipment Code for the
shelf assembly, which bundles the shelf chassis, shelf
interface pack, and cooling unit."
::= { shelfInvEntry 15 }
shelfInvRev OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The shelf hardware revision number. A value of 0 indicates
that the revision is unspecified."
::= { shelfInvEntry 16 }
shelfInvConfig OBJECT-TYPE
SYNTAX ShelfConfigType
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The shelf configuration with respect to the number of slots
for holding replaceable circuit packs.
Note: This object is no longer supported as of BTI 7000
Release 8.1.0, and is maintained in the MIB for backwards-
compatibility for management of pre-8.1 nodes."
::= { shelfInvEntry 17 }
shelfInvUSI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Unique Serial Identifier (only for FNC-branded equipment)"
::= { shelfInvEntry 18 }
shelfInvSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The serial number of the unit."
::= { shelfInvEntry 19 }
shelfInvMfgDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The shelf manufacture date in the format YYYY-MM-DD."
::= { shelfInvEntry 20 }
shelfInvMfgLoc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The shelf manufacture location."
::= { shelfInvEntry 21 }
shelfInvTestDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The shelf test date in the format YYYY-MM-DD."
::= { shelfInvEntry 22 }
shelfInvTestLoc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The shelf test location."
::= { shelfInvEntry 23 }
-----------------------------------------------------------------------
-- Objects related to the physical circuit packs inventory within
-- the slots of the system
--
-- A listing of the physically detected circuit packs and other
-- replaceable units can be retrieved from the slotInvTable. The following
-- table lists the readable objects in each entry of the slotInvTable.
-----------------------------------------------------------------------
slotInvTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlotInvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every slot on every shelf of
the NE in which a circuit pack or other replaceable unit is
seated. Each row contains a list of attributes that pertain to
the circuit pack within the slot."
::= { inventory 2 }
slotInvEntry OBJECT-TYPE
SYNTAX SlotInvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the slot inventory table."
INDEX { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx }
::= { slotInvTable 1 }
SlotInvEntry ::= SEQUENCE { slotInvShelfIdx INTEGER,
slotInvSlotTypeIdx SlotType,
slotInvSlotIdx INTEGER,
slotInvSWVersion DisplayString,
slotInvPackShortName DisplayString,
slotInvPackName DisplayString,
slotInvPackPEC DisplayString,
slotInvPackCLEI DisplayString,
slotInvPackSerialNum DisplayString,
slotInvPackRev INTEGER,
slotInvPackMfgDate DisplayString,
slotInvPackMfgLoc DisplayString,
slotInvPackTestDate DisplayString,
slotInvPackTestLoc DisplayString,
slotInvUpgradeStage UpgradeCompleteStage,
slotInvUpgradeResult INTEGER,
slotInvPackUSI DisplayString,
slotInvTempHighTh INTEGER,
slotInvTempShutdownTh INTEGER}
slotInvShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the slot inventory item is
detected."
::= { slotInvEntry 1 }
slotInvSlotTypeIdx OBJECT-TYPE
SYNTAX SlotType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The type of slot that contains the inventory item."
::= { slotInvEntry 2 }
slotInvSlotIdx OBJECT-TYPE
SYNTAX INTEGER (0..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within the shelf containing the
inventory item. The number is from 1 to 20 for regular circuit
pack slots. For main shelf interface type slots, the number
is set to 0. For 7060/7030/7020 expansion shelf interface and
cooling unit type slots, the number is set to 0.
For 7200 common communications module type slots, the number
is 1 or 2. For 7200 cooling unit type slots, the number is
from 1 to 4."
::= { slotInvEntry 3 }
slotInvSWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The version of the software running on the circuit pack in the
given slot."
::= { slotInvEntry 4 }
slotInvPackShortName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A concise representation of the name of the circuit pack or
unit."
::= { slotInvEntry 5 }
slotInvPackName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The full name of the circuit pack or unit."
::= { slotInvEntry 6 }
slotInvPackPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Product Equipment Code for the circuit pack or unit."
::= { slotInvEntry 7 }
slotInvPackCLEI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Telcordia Common Language Equipment Identifier for the
circuit pack or unit."
::= { slotInvEntry 8 }
slotInvPackSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The serial number of the unit."
::= { slotInvEntry 9 }
slotInvPackRev OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The circuit pack or unit hardware revision number. A value of
0 indicates that the revision is unspecified."
::= { slotInvEntry 10 }
slotInvPackMfgDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The circuit pack manufacture date in the format YYYY-MM-DD."
::= { slotInvEntry 11 }
slotInvPackMfgLoc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The circuit pack manufacture location."
::= { slotInvEntry 12 }
slotInvPackTestDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The circuit pack test date in the format YYYY-MM-DD."
::= { slotInvEntry 13 }
slotInvPackTestLoc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The circuit pack test location."
::= { slotInvEntry 14 }
slotInvUpgradeStage OBJECT-TYPE
SYNTAX UpgradeCompleteStage
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The stage of the circuit pack upgrade process that has been
completed."
::= { slotInvEntry 15 }
slotInvUpgradeResult OBJECT-TYPE
SYNTAX INTEGER { success (1),
failure (2) }
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates if the identified stage of the circuit pack upgrade
process has resulted in success or failure."
::= { slotInvEntry 16 }
slotInvPackUSI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Unique Serial Identifier (only for FNC-branded equipment)"
::= { slotInvEntry 17 }
slotInvTempHighTh OBJECT-TYPE
SYNTAX INTEGER (1..65535)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The circuit pack high temperature threshold."
::= { slotInvEntry 18 }
slotInvTempShutdownTh OBJECT-TYPE
SYNTAX INTEGER (1..65535)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The circuit pack shutdown temperature threshold."
::= { slotInvEntry 19 }
-----------------------------------------------------------------------
-- Objects related to the physical SFP (Small Formfactor Pluggable),
-- XFP (10 Gigabit Small Formfactor Pluggable) inventory or other
-- pluggable transceivers within the circuit packs of the system
--
-- A listing of pluggable transceiver devices that are physically
-- present can be retrieved from the pluggableInvTable. Pluggable
-- transceivers consist of SFPs and XFPs that are on the following types
-- of circuit packs:
-- <20> Multiport System Control Processor (MSCP) circuit pack
-- <20> Expansion Shelf Interface (ESI) circuit pack
-- <20> Wavelength conversion (WM, WR and WT) circuit packs
-- <20> Transponder (TPR) circuit packs
--
-- The following table lists the readable objects in each entry of the
-- pluggableInvTable.
-----------------------------------------------------------------------
pluggableInvTable OBJECT-TYPE
SYNTAX SEQUENCE OF PluggableInvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every SFP/XFP or other
pluggable present on any circuit pack or other replaceable
unit present in the NE. Each row contains a list of attributes
that pertain to the detected SFP/XFP."
::= { inventory 3 }
pluggableInvEntry OBJECT-TYPE
SYNTAX PluggableInvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the pluggable inventory table."
INDEX { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx }
::= { pluggableInvTable 1 }
PluggableInvEntry ::= SEQUENCE { pluggableInvShelfIdx INTEGER,
pluggableInvSlotTypeIdx SlotType,
pluggableInvSlotIdx INTEGER,
pluggableInvPortIdx INTEGER,
pluggableInvType INTEGER,
pluggableInvPEC DisplayString,
pluggableInvCLEI DisplayString,
pluggableInvVendorName DisplayString,
pluggableInvVendorOUI DisplayString,
pluggableInvVendorPartNum DisplayString,
pluggableInvVendorRev DisplayString,
pluggableInvVendorSerialNum DisplayString,
pluggableInvMfgDate DisplayString,
pluggableInvConnectorType INTEGER,
pluggableInvMinBitRate INTEGER,
pluggableInvMaxBitRate INTEGER,
pluggableInvNomBitRate INTEGER,
pluggableInvEncoding DisplayString,
pluggableInvWavelength FixedX100,
pluggableInvReach INTEGER,
pluggableInvTxFaultImpl TruthValue,
pluggableInvLOSImpl TruthValue,
pluggableInvDDiagImpl TruthValue,
pluggableInvTxDisableImpl TruthValue,
pluggableInvMedia INTEGER,
pluggableInvUSI DisplayString,
pluggableInvWavelengthMin FixedX100,
pluggableInvWavelengthMax FixedX100,
pluggableInvWavelengthSpacing INTEGER }
pluggableInvShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the pluggable inventory item
resides."
::= { pluggableInvEntry 1 }
pluggableInvSlotTypeIdx OBJECT-TYPE
SYNTAX SlotType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The type of slot containing the pluggable inventory item."
::= { pluggableInvEntry 2 }
pluggableInvSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot that contains the pluggable inventory
item."
::= { pluggableInvEntry 3 }
pluggableInvPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..5)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack that contains the
pluggable inventory item."
::= { pluggableInvEntry 4 }
pluggableInvType OBJECT-TYPE
SYNTAX INTEGER { unknown (1),
sfp (2),
xfp (3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of small form-factor pluggable inventory item."
::= { pluggableInvEntry 5 }
pluggableInvPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Product Equipment Code for the pluggable inventory item."
::= { pluggableInvEntry 6 }
pluggableInvCLEI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Telcordia Common Language Equipment Identifier for the
pluggable inventory item."
::= { pluggableInvEntry 7 }
pluggableInvVendorName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Vendor Name of the pluggable inventory item."
::= { pluggableInvEntry 8 }
pluggableInvVendorOUI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Vendor IEEE Organizationally Unique Identifier."
::= { pluggableInvEntry 9 }
pluggableInvVendorPartNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Vendor Part Number."
::= { pluggableInvEntry 10 }
pluggableInvVendorRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Vendor Revision Number."
::= { pluggableInvEntry 11 }
pluggableInvVendorSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Vendor Serial Number."
::= { pluggableInvEntry 12 }
pluggableInvMfgDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The manufacture date in the format YYYY-MM-DD.."
::= { pluggableInvEntry 13 }
pluggableInvConnectorType OBJECT-TYPE
SYNTAX INTEGER { unknown (1), -- Unknown or unspecified
sc (2), -- SC
fcs1cc (3), -- Fibre Channel Style 1 Copper Connector
fcs2cc (4), -- Fibre Channel Style 2 Copper Connector
bnctnc (5), -- BNC/TNC
fcch (6), -- Fibre Channel Coaxial Headers
fj (7), -- FiberJack
lc (8), -- LC
mtrj (9), -- MT-RJ
mu (10), -- MU
sg (11), -- SG
op (12), -- Optical Pigtail
hssdc2 (13), -- HSSDC II
cp (14), -- Copper Pigtail
vs (15) } -- Vendor Specific
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of connector on the pluggable unit."
::= { pluggableInvEntry 14 }
pluggableInvMinBitRate OBJECT-TYPE
SYNTAX INTEGER (0..65535)
UNITS "MBits/sec"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum bit rate supported by the pluggable. A value of 0
means unspecified."
::= { pluggableInvEntry 15 }
pluggableInvMaxBitRate OBJECT-TYPE
SYNTAX INTEGER (0..65535)
UNITS "MBits/sec"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum bit rate supported by the pluggable. A value of 0
means unspecified."
::= { pluggableInvEntry 16 }
pluggableInvNomBitRate OBJECT-TYPE
SYNTAX INTEGER (0..65535)
UNITS "MBits/sec"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The nominal bit rate supported by the pluggable. A value of 0
means unspecified."
::= { pluggableInvEntry 17 }
pluggableInvEncoding OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual comma-delimited list of serial encoding mechanisms
supported by the pluggable."
::= { pluggableInvEntry 18 }
pluggableInvWavelength OBJECT-TYPE
SYNTAX FixedX100
UNITS "nanometers/100"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The wavelength transmitted by the pluggable. A value of 0
means unspecified."
::= { pluggableInvEntry 19 }
pluggableInvReach OBJECT-TYPE
SYNTAX INTEGER (0..65535)
UNITS "kilometers"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reach supported by the pluggable. A value of 0 means
unspecified."
::= { pluggableInvEntry 20 }
pluggableInvTxFaultImpl OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if the pluggable implements the Transmit Fault
signal."
::= { pluggableInvEntry 21 }
pluggableInvLOSImpl OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if the pluggable implements the Loss of Signal
signal."
::= { pluggableInvEntry 22 }
pluggableInvDDiagImpl OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if the pluggable implements support for Digital
Diagnostics."
::= { pluggableInvEntry 23 }
pluggableInvTxDisableImpl OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if the pluggable implements support for disabling
the transmit laser."
::= { pluggableInvEntry 24 }
pluggableInvMedia OBJECT-TYPE
SYNTAX INTEGER { unknown (1),
electrical (2),
optical (3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The physical media type of the pluggable"
::= { pluggableInvEntry 25 }
pluggableInvUSI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Unique Serial Identifier (only for FNC-branded equipment)"
::= { pluggableInvEntry 26 }
pluggableInvWavelengthMin OBJECT-TYPE
SYNTAX FixedX100
UNITS "nanometers/100"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The wavelength minimum for the tunable pluggable. A value of 0
means unspecified. "
::= { pluggableInvEntry 27 }
pluggableInvWavelengthMax OBJECT-TYPE
SYNTAX FixedX100
UNITS "nanometers/100"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The wavelength maximum for the tunable pluggable.A value of 0
means unspecified."
::= { pluggableInvEntry 28 }
pluggableInvWavelengthSpacing OBJECT-TYPE
SYNTAX INTEGER ( 0 | 50 | 100 )
UNITS "GHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The wavelength spacing for the tunable pluggable. A value of 0
means unspecified."
::= { pluggableInvEntry 29 }
-----------------------------------------------------------------------
-- Objects related to the physical XFP (10 Gigabit Small Formfactor Pluggable)
-- inventory within the circuit packs of the system
--
-- A listing of pluggable transceiver devices that are physically
-- present can be retrieved from the pluggableInvTable. Pluggable
-- transceivers consist of XFPs that are on the following types
-- of circuit packs:
-- <20> Wavelength conversion (WM, WR and WT) circuit packs
-- <20> Transponder (TPR) circuit packs
--
-- The pluggableInvRestartOpTable is used to perform pluggable restarts. There is one row in
-- the table for every restartable pluggable that is provisioned on the system. The
-- pluggable restart is performed by setting the pluggableInvRestartOpCmd for the targeted
-- pluggable row to perform a coldRestart.
--
-- The following table lists the objects in each entry of the pluggableInvRestartOpTable.
-----------------------------------------------------------------------
pluggableInvRestartOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF PluggableInvRestartOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned restartable
pluggable on a circuit pack."
::= { pluggableInvOperations 1 }
pluggableInvRestartOpEntry OBJECT-TYPE
SYNTAX PluggableInvRestartOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the pluggable restart
operation table."
INDEX { pluggableInvRestartOpTypeIdx,
pluggableInvRestartOpShelfIdx,
pluggableInvRestartOpSlotIdx,
pluggableInvRestartOpPortIdx }
::= { pluggableInvRestartOpTable 1 }
PluggableInvRestartOpEntry ::= SEQUENCE { pluggableInvRestartOpTypeIdx INTEGER,
pluggableInvRestartOpShelfIdx INTEGER,
pluggableInvRestartOpSlotIdx INTEGER,
pluggableInvRestartOpPortIdx INTEGER,
pluggableInvRestartOpCmd INTEGER }
pluggableInvRestartOpTypeIdx OBJECT-TYPE
SYNTAX INTEGER { unknown (1),
xfp (3) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of small form-factor pluggable inventory item targeted for the restart
operation."
::= { pluggableInvRestartOpEntry 1 }
pluggableInvRestartOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the pluggable inventory item
resides targeted for the restart operation is provisioned."
::= { pluggableInvRestartOpEntry 2 }
pluggableInvRestartOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot that contains the pluggable inventory
item targeted for the restart operation is provisioned."
::= { pluggableInvRestartOpEntry 3 }
pluggableInvRestartOpPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..28)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack that contains the
pluggable inventory item."
::= { pluggableInvRestartOpEntry 4 }
pluggableInvRestartOpCmd OBJECT-TYPE
SYNTAX INTEGER { noOp (1),
coldRestart (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a restart operation as follows.
- coldRestart causes a pluggable restart
When this object is read, the value noOp is returned."
::= { pluggableInvRestartOpEntry 5 }
-----------------------------------------------------------------------
-- The slotInvDataTable provides a listing of any specialized data
-- records available for slot inventory entries on the system.
-----------------------------------------------------------------------
slotInvDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlotInvDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains a listing of any specialized data
records available for the slot inventory entries on the
system. Each row contains a single item of data for a
specialized data record for a slot inventory entry."
::= { inventory 4 }
slotInvDataEntry OBJECT-TYPE
SYNTAX SlotInvDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the slot inventory data table."
INDEX { slotInvDataShelfIdx,
slotInvDataSlotTypeIdx,
slotInvDataSlotIdx,
slotInvDataRecordIdx,
slotInvDataNameIdx }
::= { slotInvDataTable 1 }
SlotInvDataEntry ::= SEQUENCE { slotInvDataShelfIdx INTEGER,
slotInvDataSlotTypeIdx SlotType,
slotInvDataSlotIdx INTEGER,
slotInvDataRecordIdx Unsigned32,
slotInvDataNameIdx INTEGER,
slotInvDataValue DisplayString }
slotInvDataShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the slot inventory item is
detected."
::= { slotInvDataEntry 1 }
slotInvDataSlotTypeIdx OBJECT-TYPE
SYNTAX SlotType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of slot that contains the inventory item."
::= { slotInvDataEntry 2 }
slotInvDataSlotIdx OBJECT-TYPE
SYNTAX INTEGER (0..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within the shelf containing the
inventory item. The number is from 1 to 20 for regular circuit
pack slots. For shelfInterface and coolingUnit type slots, the
number is set to 0."
::= { slotInvDataEntry 3 }
slotInvDataRecordIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specialized data record index."
::= { slotInvDataEntry 4 }
slotInvDataNameIdx OBJECT-TYPE
SYNTAX INTEGER { wavelength (1),
loss (2),
dispersion (3) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The name of the data item."
::= { slotInvDataEntry 5 }
slotInvDataValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the data item."
::= { slotInvDataEntry 6 }
-----------------------------------------------------------------------
-- Objects related to provisioned shelves on the system
--
-- A listing of provisioned shelves is contained in the shelfTable of
-- the BTI 7000 Series MIB. When retrieved, this table lists one row
-- for every provisioned shelf. There is at least one row for the main
-- shelf that is auto provisioned and it can never be deprovisioned.
-- There is also one additional row for each provisioned expansion
-- shelf.
--
-- To manually provision an expansion shelf, a row must be created in
-- the shelfTable. To deprovision an expansion shelf, its row must be
-- destroyed. The following table lists the objects in each entry of
-- the shelfTable.
-----------------------------------------------------------------------
shelfTable OBJECT-TYPE
SYNTAX SEQUENCE OF ShelfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned shelf on the
NE. Each row contains a list of attributes that pertain to a
provisioned shelf."
::= { equipment 1 }
shelfEntry OBJECT-TYPE
SYNTAX ShelfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the shelf table."
INDEX { shelfIdx }
::= { shelfTable 1 }
ShelfEntry ::= SEQUENCE { shelfIdx INTEGER,
shelfProvConfig ShelfConfigType,
shelfDiscConfig ShelfConfigType,
shelfType ShelfType,
shelfPEC DisplayString,
shelfAdminStatus AdminStatus,
shelfOperStatus OperStatus,
shelfOperStatQlfr OperStatQlfr,
shelfId DisplayString,
shelfCustom1 DisplayString,
shelfCustom2 DisplayString,
shelfCustom3 DisplayString,
shelfPowerFeedA PowerFeedModeType,
shelfPowerFeedB PowerFeedModeType,
shelfRowStatus RowStatus }
shelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf that has been provisioned. This is set
to 1 for the main shelf. Otherwise, the number is based on the
expansion shelf port number on which this shelf is expected to
be detected and the number of hops from the main shelf."
::= { shelfEntry 1 }
shelfProvConfig OBJECT-TYPE
SYNTAX ShelfConfigType
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION "The provisioned configuration for the shelf.
Note: This object is no longer supported as of BTI 7000
Release 8.1.0, and is maintained in the MIB for backwards-
compatibility for management of pre-8.1 nodes."
DEFVAL { sixSlot }
::= { shelfEntry 2 }
shelfDiscConfig OBJECT-TYPE
SYNTAX ShelfConfigType
MAX-ACCESS accessible-for-notify
STATUS deprecated
DESCRIPTION "The configuration of the actual shelf discovered.
Note: This object is no longer supported as of BTI 7000
Release 8.1.0, and is maintained in the MIB for backwards-
compatibility for management of pre-8.1 nodes."
::= { shelfEntry 3 }
shelfType OBJECT-TYPE
SYNTAX ShelfType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the provisioned shelf is a main or expansion
shelf. Only expansion shelves can be created. The main shelf
is automatically provisioned and can never be de-provisioned."
DEFVAL { expansion }
::= { shelfEntry 4 }
shelfPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates the provisioned shelf Product Equipment Code. This
is a mandatory object when a row of the shelf table is
created. The PEC can only be set at the time of row creation,
and it cannot be edited later."
::= { shelfEntry 5 }
shelfAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the shelf."
DEFVAL { enabled }
::= { shelfEntry 6 }
shelfOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the shelf."
::= { shelfEntry 7 }
shelfOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual list of qualifiers of the reported operational
status of the shelf."
::= { shelfEntry 8 }
shelfId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
shelf in a manner useful to the user such as the location
where the shelf is installed."
DEFVAL { "" }
::= { shelfEntry 9 }
shelfCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { shelfEntry 10 }
shelfCustom2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { shelfEntry 11 }
shelfCustom3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { shelfEntry 12 }
shelfPowerFeedA OBJECT-TYPE
SYNTAX PowerFeedModeType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The power feed mode for rail A."
DEFVAL { dc }
::= { shelfEntry 13 }
shelfPowerFeedB OBJECT-TYPE
SYNTAX PowerFeedModeType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The power feed mode for rail B."
DEFVAL { dc }
::= { shelfEntry 14 }
shelfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
shelf table, which in turn controls provisioning and
deprovisioning of shelf objects."
::= { shelfEntry 100 }
-----------------------------------------------------------------------
-- Objects related to provisioned circuit packs on the system
--
-- A listing of provisioned circuit packs is contained in the cpTable
-- of the BTI 7000 Series MIB. When retrieved, this table includes one
-- row for every provisioned circuit pack. There is at least one row
-- for the System Control Processor (SCP) circuit pack that is auto
-- provisioned in slot 5 of the main shelf (This circuit pack
-- cannot be deprovisioned.). There is also an additional row for every
-- other provisioned circuit pack.
--
-- To manually provision a circuit pack, a row must be created in the
-- cpTable. To deprovision a circuit pack, its row must be destroyed.
--
-- Note: Circuit packs can only be provisioned in slots of the type
-- described as regular in the slotInvTable. Shelf interface and
-- cooling units do not need to be provisioned.
--
-- The following table lists the objects in each entry of the cpTable.
-----------------------------------------------------------------------
cpTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned circuit pack
on the NE. Each row contains a list of attributes that pertain
to a provisioned circuit pack."
::= { equipment 2 }
cpEntry OBJECT-TYPE
SYNTAX CpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the circuit pack table."
INDEX { cpTypeIdx,
cpShelfIdx,
cpSlotIdx }
::= { cpTable 1 }
CpEntry ::= SEQUENCE { cpTypeIdx CpType,
cpShelfIdx INTEGER,
cpSlotIdx INTEGER,
cpPEC DisplayString,
cpAdminStatus AdminStatus,
cpOperStatus OperStatus,
cpOperStatQlfr OperStatQlfr,
cpId DisplayString,
cpCustom1 DisplayString,
cpCustom2 DisplayString,
cpCustom3 DisplayString,
cpUpgradeStage UpgradeCompleteStage,
cpUpgradeResult INTEGER,
cpRowStatus RowStatus }
cpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The specific type of circuit pack provisioned."
::= { cpEntry 1 }
cpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the circuit pack is
provisioned."
::= { cpEntry 2 }
cpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot in which the circuit pack is
provisioned."
::= { cpEntry 3 }
cpPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates the provisioned circuit pack Product Equipment Code.
This is a mandatory object when a row of the circuit pack
table is created. The PEC can only be set at the time of row
creation, and it cannot be edited later."
::= { cpEntry 4 }
cpAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the circuit pack."
DEFVAL { enabled }
::= { cpEntry 5 }
cpOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the circuit pack."
::= { cpEntry 6 }
cpOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual list of qualifiers of the reported operational
status of the circuit pack."
::= { cpEntry 7 }
cpId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
circuit pack in a manner useful to the user."
DEFVAL { "" }
::= { cpEntry 8 }
cpCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { cpEntry 9 }
cpCustom2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { cpEntry 10 }
cpCustom3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { cpEntry 11 }
cpUpgradeStage OBJECT-TYPE
SYNTAX UpgradeCompleteStage
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Used in notifications sent during the circuit pack software
upgrade process. It indicates the stage of the circuit pack
upgrade process that has been completed."
::= { cpEntry 12 }
cpUpgradeResult OBJECT-TYPE
SYNTAX INTEGER { success (1),
failure (2) }
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates if the identified stage of the circuit pack upgrade
process has resulted in success or failure."
::= { cpEntry 13 }
cpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
circuit pack table, which in turn controls the provisioning
and de-provisioning of circuit pack objects."
::= { cpEntry 100 }
-----------------------------------------------------------------------
-- Objects related to provisioned Optical Amplifier facilities
--
-- A listing of provisioned optical amplifiers is contained in the
-- oaTable of the BTI 7000 Series MIB. When retrieved, this table
-- provides one row for each provisioned optical amplifier.
--
-- To manually provision a optical amplifier, a row must be created in
-- the oaTable. To deprovision a optical amplifier, its row must be
-- destroyed.
--
-- The following table lists the objects in each entry of the oaTable.
-----------------------------------------------------------------------
oaTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned optical
amplifier facility on the NE. Each row contains a list of
attributes that pertain to the optical amplifier."
::= { facilities 1 }
oaEntry OBJECT-TYPE
SYNTAX OaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical amplifier table."
INDEX { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx }
::= { oaTable 1 }
OaEntry ::= SEQUENCE { oaTypeIdx OaType,
oaShelfIdx INTEGER,
oaSlotIdx INTEGER,
oaIdx INTEGER,
oaCaseTempMaxTh INTEGER,
oaCaseTempMaxShutdownTh INTEGER,
oaLaserTempMinShutdownTh INTEGER,
oaLaserTempMaxShutdownTh INTEGER,
oaOpticalPwrReceivedMinTh FixedX10,
oaOpticalPwrReceivedMaxTh FixedX10,
oaSSIOpticalPwrReceivedMaxTh FixedX10,
oaOpticalPwrTransmittedMinTh FixedX10,
oaOpticalPwrTransmittedMaxTh FixedX10,
oaBackReflectionSafetyTh FixedX10,
oaMSInsertionLossMaxTh FixedX10,
oaCaseTemp INTEGER,
oaLaser1Temp INTEGER,
oaLaser2Temp INTEGER,
oaOpticalPwrReceived FixedX10,
oaSSIOpticalPwrReceived FixedX10,
oaOpticalPwrTransmitted FixedX10,
oaMSInsertionLoss FixedX10,
oaEffectiveGain FixedX10,
oaFSOOpticalPwrTransmitted FixedX10,
oaLaser1Current FixedX10,
oaLaser2Current FixedX10,
oaLaser1Power FixedX10,
oaLaser2Power FixedX10,
oaOpticalBackReflection FixedX10,
oaVariableOpticalAttenuation FixedX10,
oaAdminStatus AdminStatus,
oaOperStatus OperStatus,
oaOperStatQlfr OperStatQlfr,
oaAutoEnableTimer HoursAndMinutes,
oaActAutoEnableTimer HoursAndMinutes,
oaModeSetting INTEGER,
oaGainSetting FixedX10,
oaPwrSetting FixedX10,
oaTiltCompSetting FixedX10,
oaStatus INTEGER,
oaLaserStatus INTEGER,
oaId1 DisplayString,
oaId2 DisplayString,
oaFiberType FiberType,
oaGrid WDMGrid,
oaNumChannels INTEGER,
oaCustom1 DisplayString,
oaCustom2 DisplayString,
oaCustom3 DisplayString,
oaWavelength FixedX100,
oaRemoteId DisplayString,
oaRowStatus RowStatus }
oaTypeIdx OBJECT-TYPE
SYNTAX OaType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The specific type of optical amplifier provisioned."
::= { oaEntry 1 }
oaShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the optical amplifier
facility is provisioned."
::= { oaEntry 2 }
oaSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot in which the optical amplifier facility
is provisioned."
::= { oaEntry 3 }
oaIdx OBJECT-TYPE
SYNTAX INTEGER (1..1)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
optical amplifier facility is provisioned."
::= { oaEntry 4 }
oaCaseTempMaxTh OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The case temperature threshold."
DEFVAL { 60 }
::= { oaEntry 5 }
oaCaseTempMaxShutdownTh OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The case temperature shutdown threshold."
::= { oaEntry 6 }
oaLaserTempMinShutdownTh OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser temperature minimum shutdown threshold. A default
value is provided when the optical amplifier is created based
on the optical amplifier type provisioned."
::= { oaEntry 7 }
oaLaserTempMaxShutdownTh OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser temperature maximum shutdown threshold. A default
value is provided when the optical amplifier is created based
on the optical amplifier type provisioned."
::= { oaEntry 8 }
oaOpticalPwrReceivedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The optical power received minimum threshold. A default value
is provided when the optical amplifier is created based on the
optical amplifier type provisioned."
::= { oaEntry 9 }
oaOpticalPwrReceivedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The optical power received maximum threshold. A default value
is provided when the optical amplifier is created based on the
optical amplifier type provisioned."
::= { oaEntry 10 }
oaSSIOpticalPwrReceivedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The secondary stage input optical power received maximum
threshold. This object is applicable only to OLAM type
amplifiers."
DEFVAL { 55 }
::= { oaEntry 11 }
oaOpticalPwrTransmittedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The optical power transmitted minimum threshold. A default
value is provided when the optical amplifier is created based
on the optical amplifier type provisioned."
::= { oaEntry 12 }
oaOpticalPwrTransmittedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The optical power transmitted maximum threshold. A default
value is provided when the optical amplifier is created based
on the optical amplifier type provisioned."
::= { oaEntry 13 }
oaBackReflectionSafetyTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical back reflection safety threshold."
::= { oaEntry 14 }
oaMSInsertionLossMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This is the mid-stage maximum insertion loss signal threshold.
It applies to mid-stage access amplifiers only."
DEFVAL { 150 }
::= { oaEntry 15 }
oaCaseTemp OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier case temperature."
::= { oaEntry 16 }
oaLaser1Temp OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature of the optical amplifier laser 1."
::= { oaEntry 17 }
oaLaser2Temp OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature of the optical amplifier laser 2."
::= { oaEntry 18 }
oaOpticalPwrReceived OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the amplifier."
::= { oaEntry 19 }
oaSSIOpticalPwrReceived OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the second stage of the
amplifier. It applies to mid-stage access amplifiers only."
::= { oaEntry 20 }
oaOpticalPwrTransmitted OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the amplifier."
::= { oaEntry 21 }
oaMSInsertionLoss OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The mid-stage insertion loss. This object is only applicable
to OLAM type amplifiers."
::= { oaEntry 22 }
oaEffectiveGain OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The effective gain level of the optical amplifier."
::= { oaEntry 33 }
oaFSOOpticalPwrTransmitted OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the first stage
of the amplifier. It applies to mid-stage access amplifiers
only."
::= { oaEntry 34 }
oaLaser1Current OBJECT-TYPE
SYNTAX FixedX10
UNITS "mAmp/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 1 current."
::= { oaEntry 35 }
oaLaser2Current OBJECT-TYPE
SYNTAX FixedX10
UNITS "mAmp/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 2 current."
::= { oaEntry 36 }
oaLaser1Power OBJECT-TYPE
SYNTAX FixedX10
UNITS "mWatts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 1 power."
::= { oaEntry 37 }
oaLaser2Power OBJECT-TYPE
SYNTAX FixedX10
UNITS "mWatts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 2 power."
::= { oaEntry 38 }
oaOpticalBackReflection OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical back reflection of the amplifier."
::= { oaEntry 39 }
oaVariableOpticalAttenuation OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The variable optical attenuation of the amplifier."
::= { oaEntry 40 }
oaAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the optical amplifier."
DEFVAL { enabled }
::= { oaEntry 41 }
oaOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the optical amplifier."
::= { oaEntry 42 }
oaOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual list of qualifiers of the reported operational
status of the optical amplifier."
::= { oaEntry 43 }
oaAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the auto-enable timer for the targeted optical
amplifier. This value only applies if the oaAdminStatus object
is set to autoEnabled. Otherwise, the value returned is
000-00. The supported range of values is 000-00 to 096-00."
DEFVAL { "008-00" }
::= { oaEntry 44 }
oaActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time remaining on the auto-enable timer, if it
is actively counting down. Otherwise, the value returned is
000-00."
::= { oaEntry 45 }
oaModeSetting OBJECT-TYPE
SYNTAX INTEGER { constantGain (2),
constantPower (3) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The desired mode of operation to which this optical amplifier
is set."
DEFVAL { constantGain }
::= { oaEntry 46 }
oaGainSetting OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The effective gain (excluding ASE) set point. A default value
is provided when the optical amplifier is created based on the
optical amplifier type provisioned."
::= { oaEntry 47 }
oaPwrSetting OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The signal output power (excluding ASE) set point. A default
value is provided when the optical amplifier is created based
on the optical amplifier type provisioned."
::= { oaEntry 48 }
oaTiltCompSetting OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The desired tilt compensation to which this optical amplifier
is set."
DEFVAL { 0 }
::= { oaEntry 49 }
oaStatus OBJECT-TYPE
SYNTAX INTEGER { none (1),
constantGain (2),
constantPower (3),
eyeSafe (4),
shutdown (5),
constantGainOff (6),
constantPowerOff (7),
constantLaserCurrent (8),
constantLaserCurrentOff (9),
constantLaserPower (10),
constantLaserPowerOff (11) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The specific operational status of the amplifier."
::= { oaEntry 50 }
oaLaserStatus OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The actual operational status of the optical amplifier laser."
::= { oaEntry 51 }
oaId1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
optical amplifier in a manner useful to the user."
DEFVAL { "" }
::= { oaEntry 52 }
oaId2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
optical amplifier in a manner useful to the user."
DEFVAL { "" }
::= { oaEntry 53 }
oaFiberType OBJECT-TYPE
SYNTAX FiberType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optional specification of the fiber type that interfaces
with the optical amplifier."
DEFVAL { none }
::= { oaEntry 54 }
oaGrid OBJECT-TYPE
SYNTAX WDMGrid
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optional indication of the WDM grid to which the link
conforms."
DEFVAL { none }
::= { oaEntry 55 }
oaNumChannels OBJECT-TYPE
SYNTAX INTEGER (0..40)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optional indication of the number of channels that the link
is carrying."
DEFVAL { 0 }
::= { oaEntry 56 }
oaCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { oaEntry 57 }
oaCustom2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { oaEntry 58 }
oaCustom3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { oaEntry 59 }
oaWavelength OBJECT-TYPE
SYNTAX FixedX100
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The wavelength transmitted from the OA port. This object
applies only to single channel amplifiers (sba, spa)."
::= { oaEntry 60 }
oaRemoteId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Identifies the remote node and port to which the
optical amplifier port is connected, in the format
prescribed by the PSM network management system."
DEFVAL { "" }
::= { oaEntry 61 }
oaRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
optical amplifier table, which in turn controls provisioning
and deprovisioning of optical amplifier facilities."
::= { oaEntry 100 }
-----------------------------------------------------------------------
-- Objects related to provisioned Optical Transceivers on
-- Wavelength Conversion Circuit Packs
--
-- A listing of provisioned optical transceiver ports is contained in the
-- xcvrTable of the BTI 7000 Series MIB. When retrieved, this table includes one
-- row for each provisioned transceiver port entity.
--
-- Optical transceiver ports are provisioned on wavelength conversion circuit
-- packs that include:
-- <20> Wavelength Manager (WM)
-- <20> Wavelength Regenerator (WR)
-- <20> Wavelength Translator (WT)
-- <20> Transponder (TPR)
-- The following table lists the objects in each entry of the xcvrTable.
-----------------------------------------------------------------------
xcvrTable OBJECT-TYPE
SYNTAX SEQUENCE OF XcvrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned optical
transceiver on a wavelength translator, regenerator or manager
card. Each row contains a list of attributes that pertain to
the transceiver."
::= { facilities 2 }
xcvrEntry OBJECT-TYPE
SYNTAX XcvrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical transceiver table."
INDEX { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx }
::= { xcvrTable 1 }
XcvrEntry ::= SEQUENCE { xcvrTypeIdx XcvrType,
xcvrShelfIdx INTEGER,
xcvrSlotIdx INTEGER,
xcvrIdx INTEGER,
xcvrOpticalPwrReceivedMinTh FixedX10,
xcvrOpticalPwrReceivedMaxTh FixedX10,
xcvrOpticalPwrTransmittedMinTh FixedX10,
xcvrOpticalPwrTransmittedMaxTh FixedX10,
xcvrOpticalPwrReceived FixedX10,
xcvrOpticalPwrTransmitted FixedX10,
xcvrProtSwEvtType ProtSwEvtType,
xcvrPEC DisplayString,
xcvrAdminStatus AdminStatus,
xcvrOperStatus OperStatus,
xcvrOperStatQlfr OperStatQlfr,
xcvrAutoEnableTimer HoursAndMinutes,
xcvrActAutoEnableTimer HoursAndMinutes,
xcvrProtocol XcvrProtocolType,
xcvrWavelength FixedX100,
xcvrVendorPN1 DisplayString,
xcvrVendorPN2 DisplayString,
xcvrVendorPN3 DisplayString,
xcvrPhyPMMon INTEGER,
xcvrFPSD INTEGER,
xcvrLaserStatus INTEGER,
xcvrId1 DisplayString,
xcvrId2 DisplayString,
xcvrFiberType FiberType,
xcvrGrid WDMGrid,
xcvrCustom1 DisplayString,
xcvrCustom2 DisplayString,
xcvrCustom3 DisplayString,
xcvrTraceLabel DisplayString,
xcvrExpectedTraceLabel DisplayString,
xcvrReceivedTraceLabel DisplayString,
xcvrSDBERTh BERType,
xcvrLoopbackType LoopbackType,
xcvrRemoteId DisplayString,
xcvrRowStatus RowStatus }
xcvrTypeIdx OBJECT-TYPE
SYNTAX XcvrType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The specific type of wavelength conversion function of the
circuit pack on which the transceiver is provisioned."
::= { xcvrEntry 1 }
xcvrShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the transceiver is
provisioned."
::= { xcvrEntry 2 }
xcvrSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within which the transceiver is
provisioned."
::= { xcvrEntry 3 }
xcvrIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
transceiver is provisioned."
::= { xcvrEntry 4 }
xcvrOpticalPwrReceivedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received minimum threshold."
::= { xcvrEntry 5 }
xcvrOpticalPwrReceivedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received maximum threshold."
::= { xcvrEntry 6 }
xcvrOpticalPwrTransmittedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted minimum threshold."
::= { xcvrEntry 7 }
xcvrOpticalPwrTransmittedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted maximum threshold."
::= { xcvrEntry 8 }
xcvrOpticalPwrReceived OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power received on the input of the transceiver."
::= { xcvrEntry 9 }
xcvrOpticalPwrTransmitted OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power transmitted at the output of the
transceiver."
::= { xcvrEntry 10 }
xcvrProtSwEvtType OBJECT-TYPE
SYNTAX ProtSwEvtType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates the type of protection switching event that has
occured on an optical transceiver port."
::= { xcvrEntry 11 }
xcvrPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned transceiver Product Equipment Code
used to validate the physically present transceiver."
DEFVAL { "" }
::= { xcvrEntry 12 }
xcvrAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the optical transceiver."
DEFVAL { enabled }
::= { xcvrEntry 13 }
xcvrOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the optical transceiver."
::= { xcvrEntry 14 }
xcvrOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the optical transceiver."
::= { xcvrEntry 15 }
xcvrAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the auto-enable timer for the targeted optical
transceiver. This value only applies if the xcvrAdminStatus
object is set to autoEnabled. Otherwise, the value returned is
000-00."
DEFVAL { "008-00" }
::= { xcvrEntry 16 }
xcvrActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time remaining on the auto-enable timer if it is
actively counting down. Otherwise, the value returned is
000-00."
::= { xcvrEntry 17 }
xcvrProtocol OBJECT-TYPE
SYNTAX XcvrProtocolType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The protocol of the service to be carried by the port. This is
a mandatory object when a row of the transceiver table is
created."
::= { xcvrEntry 18 }
xcvrWavelength OBJECT-TYPE
SYNTAX FixedX100
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The wavelength to be transmitted by the transceiver port. This
is a mandatory object when a row of the transceiver table is
created for ports that have a pluggable transceiver."
::= { xcvrEntry 19 }
xcvrVendorPN1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
physically present transceiver."
DEFVAL { "" }
::= { xcvrEntry 20 }
xcvrVendorPN2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
physically present transceiver."
DEFVAL { "" }
::= { xcvrEntry 21 }
xcvrVendorPN3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
physically present transceiver."
DEFVAL { "" }
::= { xcvrEntry 22 }
xcvrPhyPMMon OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the port is configured to report threshold
crossing conditions for physical layer performance monitoring
parameters."
DEFVAL { disabled }
::= { xcvrEntry 23 }
xcvrFPSD OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the port is configured for Fault Propagation Shut
Down."
DEFVAL { disabled }
::= { xcvrEntry 24 }
xcvrLaserStatus OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2),
idle (3),
aisl (4),
msais (5),
odu2ais (6),
prbs (7),
remoteFault (8),
odu2lck (9),
odu2oci (10) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of the operational status of the transceiver
laser."
::= { xcvrEntry 25 }
xcvrId1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
optical transceiver in a manner useful to the user."
DEFVAL { "" }
::= { xcvrEntry 26 }
xcvrId2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
optical transceiver in a manner useful to the user."
DEFVAL { "" }
::= { xcvrEntry 27 }
xcvrFiberType OBJECT-TYPE
SYNTAX FiberType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optional specification of the fiber type that interfaces to
the optical transceiver."
DEFVAL { none }
::= { xcvrEntry 28 }
xcvrGrid OBJECT-TYPE
SYNTAX WDMGrid
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optical indication of the WDM grid the link conforms."
DEFVAL { none }
::= { xcvrEntry 29 }
xcvrCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { xcvrEntry 30 }
xcvrCustom2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { xcvrEntry 31 }
xcvrCustom3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { xcvrEntry 32 }
xcvrTraceLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "If specified, this attribute will describe the trace label to
be used in the outgoing OTN or SONET/SDH trace."
DEFVAL { "" }
::= { xcvrEntry 33 }
xcvrExpectedTraceLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This attribute will describe the trace label that is expected
to be received in the incoming OTN or SONET/SDH trace. If
specified, this expected trace label will be compared to the
actual value for xcvrReceivedTraceLabel, and a trace mismatch
alarm will be raised if the two trace labels do not match."
DEFVAL { "" }
::= { xcvrEntry 34 }
xcvrReceivedTraceLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The actual received trace label on the incoming OTN or
SONET/SDH trace."
::= { xcvrEntry 35 }
xcvrSDBERTh OBJECT-TYPE
SYNTAX BERType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Bit Error Rate threshold above which the Signal Degrade
condition is raised."
DEFVAL { none }
::= { xcvrEntry 36 }
xcvrLoopbackType OBJECT-TYPE
SYNTAX LoopbackType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The loopback type that is currently active on the xcvr"
DEFVAL { noLoopback }
::= { xcvrEntry 37 }
xcvrRemoteId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Identifies the remote node and port to which the
transceiver port is connected, in the format
prescribed by the PSM network management system."
DEFVAL { "" }
::= { xcvrEntry 38 }
xcvrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
Transceiver table, which in turn controls provisioning and
deprovisioning of optical transceiver facilities."
::= { xcvrEntry 100 }
-----------------------------------------------------------------------
-- Objects related to provisioned Active Multiplexer-Demultiplexer
-- ports on AMD cards
--
-- A listing of provisioned active multiplexer-demultiplexer ports is
-- contained in the amdTable of the BTI 7000 Series MIB. When retrieved,
-- this table includes one row for each port on active
-- multiplexer-demultiplexer packs.
--
-- All entries in the amdTable are created and deleted automatically as
-- a result of the creation and deletion of the supporting entry in
-- the cpTable.
--
-- The following table lists the objects in each entry of the amdTable.
-----------------------------------------------------------------------
amdTable OBJECT-TYPE
SYNTAX SEQUENCE OF AmdEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "This table contains one row for every provisioned active
multiplexer-demultiplexer facility. AMD facilities include AMD
line facilities and AMD channel facilities. Each row contains
a list of attributes that pertain to one facility."
::= { facilities 3 }
amdEntry OBJECT-TYPE
SYNTAX AmdEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The conceptual row object of the Active Mux-Demux table."
INDEX { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx }
::= { amdTable 1 }
AmdEntry ::= SEQUENCE { amdTypeIdx AmdType,
amdShelfIdx INTEGER,
amdSlotIdx INTEGER,
amdLineIdx INTEGER,
amdPortIdx AmdPortType,
amdOpticalPwrReceivedMinTh FixedX10,
amdOpticalPwrReceivedMaxTh FixedX10,
amdOpticalPwrTransmittedTarget FixedX10,
amdOpticalAttenuationTarget FixedX10,
amdOpticalPwrReceived FixedX10,
amdOpticalPwrTransmitted FixedX10,
amdOpticalAttentuation FixedX10,
amdAdminStatus AdminStatus,
amdOperStatus OperStatus,
amdOperStatQlfr OperStatQlfr,
amdAutoEnableTimer HoursAndMinutes,
amdActAutoEnableTimer HoursAndMinutes,
amdWavelength FixedX100,
amdId1 DisplayString,
amdId2 DisplayString,
amdFiberType FiberType,
amdGrid WDMGrid,
amdCustom1 DisplayString,
amdCustom2 DisplayString,
amdCustom3 DisplayString,
amdRowStatus RowStatus }
amdTypeIdx OBJECT-TYPE
SYNTAX AmdType
MAX-ACCESS accessible-for-notify
STATUS obsolete
DESCRIPTION "The specific type of active multiplexer-demultiplexer circuit
pack on which the facility is provisioned."
::= { amdEntry 1 }
amdShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS obsolete
DESCRIPTION "The number of the shelf on which the active
multiplexer-demultiplexer facility is provisioned."
::= { amdEntry 2 }
amdSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS accessible-for-notify
STATUS obsolete
DESCRIPTION "The number of the slot within which the active
multiplexer-demultiplexer facility is provisioned."
::= { amdEntry 3 }
amdLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..1)
MAX-ACCESS accessible-for-notify
STATUS obsolete
DESCRIPTION "The number of the multiplexed wavelength line on the AMD
circuit pack."
::= { amdEntry 4 }
amdPortIdx OBJECT-TYPE
SYNTAX AmdPortType
MAX-ACCESS accessible-for-notify
STATUS obsolete
DESCRIPTION "Identifies a specific port on the identified line of the AMD
circuit pack."
::= { amdEntry 5 }
amdOpticalPwrReceivedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "This is the optical power received minimum threshold."
::= { amdEntry 6 }
amdOpticalPwrReceivedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "This is the optical power received maximum threshold."
::= { amdEntry 7 }
amdOpticalPwrTransmittedTarget OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "This is the optical power transmitted target level."
::= { amdEntry 8 }
amdOpticalAttenuationTarget OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "This is the optical power attenuation target level."
::= { amdEntry 9 }
amdOpticalPwrReceived OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS obsolete
DESCRIPTION "The optical input power received for the channel."
::= { amdEntry 10 }
amdOpticalPwrTransmitted OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS obsolete
DESCRIPTION "The optical power level transmitted for the channel."
::= { amdEntry 11 }
amdOpticalAttentuation OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS accessible-for-notify
STATUS obsolete
DESCRIPTION "The optical power attenuation for the line."
::= { amdEntry 12 }
amdAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "The administrative status of the AMD port."
DEFVAL { enabled }
::= { amdEntry 13 }
amdOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The reported operational status of the AMD port."
::= { amdEntry 14 }
amdOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the AMD port."
::= { amdEntry 15 }
amdAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "Specifies the auto-enable timer for the targeted AMD port.
This value only applies if the amdAdminStatus object is set to
autoEnabled. Otherwise, the value returned is 000-00."
DEFVAL { "008-00" }
::= { amdEntry 16 }
amdActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates the time remaining on the auto-enable timer if it is
actively counting down. Otherwise, the value returned is
000-00."
::= { amdEntry 17 }
amdWavelength OBJECT-TYPE
SYNTAX FixedX100
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The wavelength transmitted from the AMD port. This object
applies only to channel ports."
::= { amdEntry 18 }
amdId1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "Textual data recorded by the user to describe the provisioned
optical transceiver in a manner useful to the user."
DEFVAL { "" }
::= { amdEntry 19 }
amdId2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "Textual data recorded by the user to describe the provisioned
optical transceiver in a manner useful to the user."
DEFVAL { "" }
::= { amdEntry 20 }
amdFiberType OBJECT-TYPE
SYNTAX FiberType
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "An optional specification of the fiber type that interfaces to
the AMD port."
DEFVAL { none }
::= { amdEntry 21 }
amdGrid OBJECT-TYPE
SYNTAX WDMGrid
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "An optical indication of the WDM grid to which the AMD port
link conforms."
DEFVAL { none }
::= { amdEntry 22 }
amdCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { amdEntry 23 }
amdCustom2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { amdEntry 24 }
amdCustom3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { amdEntry 25 }
amdRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS accessible-for-notify
STATUS obsolete
DESCRIPTION "The active multiplexer-demultiplexer table RowStatus object is
not readable or writeable because all entries in the AMD table
are automatically created and deleted when the AMD circuit
pack is created or deleted. This AMD row status object is used
only in database change notifications to indicate if the row
has been created or deleted."
::= { amdEntry 100 }
-----------------------------------------------------------------------
-- Objects related to optical facilities carried on the ports of
-- provisioned passive circuit packs.
--
-- A listing of provisioned passive circuit pack ports is contained
-- in the assivePortTable of the BTI 7000 Series MIB. When retrieved,
-- this table includes one row for each port on passive packs.
--
-- All entries in the passivePortTable are created and deleted
-- automatically as a result of the creation and deletion of the
-- supporting entry in the cpTable.
--
-- The following table lists the objects in each entry of the
-- passivePortTable.
-----------------------------------------------------------------------
passivePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PassivePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for each port on every provisioned
passive circuit pack on the NE. Each list contains a list of
attributes that pertain to the passive port."
::= { facilities 4 }
passivePortEntry OBJECT-TYPE
SYNTAX PassivePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the passive circuit pack port
table."
INDEX { passivePortCpTypeIdx,
passivePortShelfIdx,
passivePortSlotIdx,
passivePortLineIdx,
passivePortTypeIdx }
::= { passivePortTable 1 }
PassivePortEntry ::= SEQUENCE { passivePortCpTypeIdx CpType,
passivePortShelfIdx INTEGER,
passivePortSlotIdx INTEGER,
passivePortLineIdx INTEGER,
passivePortTypeIdx PassivePortType,
passivePortId1 DisplayString,
passivePortId2 DisplayString,
passivePortFiberType FiberType,
passivePortGrid WDMGrid,
passivePortNumChannels INTEGER,
passivePortWavelength FixedX100,
passivePortCustom1 DisplayString,
passivePortCustom2 DisplayString,
passivePortCustom3 DisplayString,
passivePortRemoteId DisplayString,
passivePortRowStatus RowStatus }
passivePortCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of circuit pack on which the passive port is found."
::= { passivePortEntry 1 }
passivePortShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the passive circuit pack port
is provisioned."
::= { passivePortEntry 2 }
passivePortSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the passive circuit pack
port is provisioned."
::= { passivePortEntry 3 }
passivePortLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies the multiplexed multi-channel optical facility
instance associated with the targeted passive port."
::= { passivePortEntry 4 }
passivePortTypeIdx OBJECT-TYPE
SYNTAX PassivePortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies the specific passive port on the circuit pack
according to function."
::= { passivePortEntry 5 }
passivePortId1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An optional name used to identify the passive circuit pack
port facility."
::= { passivePortEntry 6 }
passivePortId2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An optional identifier for the passive circuit pack port
circuit."
::= { passivePortEntry 7 }
passivePortFiberType OBJECT-TYPE
SYNTAX FiberType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An optional specification of the fiber type interfacing the
passive circuit pack port."
::= { passivePortEntry 8 }
passivePortGrid OBJECT-TYPE
SYNTAX WDMGrid
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An optional indication of the DWM grid that the link conforms
to."
::= { passivePortEntry 9 }
passivePortNumChannels OBJECT-TYPE
SYNTAX INTEGER (1..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An optional indication of the number of channels that the link
is carrying. This field does not apply to individual channel
type ports."
::= { passivePortEntry 10 }
passivePortWavelength OBJECT-TYPE
SYNTAX FixedX100
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of the wavelength that the port is carrying."
::= { passivePortEntry 11 }
passivePortCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
::= { passivePortEntry 12 }
passivePortCustom2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
::= { passivePortEntry 13 }
passivePortCustom3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
::= { passivePortEntry 14 }
passivePortRemoteId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Identifies the remote node and port to which the
passive card port is connected, in the format
prescribed by the PSM network management system."
DEFVAL { "" }
::= { passivePortEntry 15 }
passivePortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The passive port table RowStatus object is not readable or
writeable because all entries in the passive port table are
automatically created and deleted when the circuit pack is
created or deleted. This passive port row status object is
used only in database change notifications to indicate if the
row has been created or deleted."
::= { passivePortEntry 100 }
-----------------------------------------------------------------------
-- Objects related to provisioned SONET OC-N facilities on
-- Muxponder Circuit Packs
--
-- A listing of provisioned SONET OC-N ports is contained in the
-- ocnTable of the BTI 7000 Series MIB. When retrieved, this table
-- includes one row for each provisioned SONET OC-N port facility, that
-- includes OC-48 and OC-192 facilities.
--
-- Note: The ocnTable manages the OC-N facilities on muxponder circuit
-- packs. It is not used for OC-N services on wavelength conversion type
-- circuit packs. For management of these facilities, the xcvrTable is
-- used.
--
-- To manually provision an OC-48 or OC-192 facility, a row must be
-- created in the ocnTable. To deprovision an OC-N facility, its row must
-- be destroyed.
--
-- The following table lists the objects in each entry of the ocnTable.
-----------------------------------------------------------------------
ocnTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned SONET OC-N
facility on the system. Each row contains a list of attributes
that pertain to the facility."
::= { facilities 5 }
ocnEntry OBJECT-TYPE
SYNTAX OcnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the OC-N table."
INDEX { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx }
::= { ocnTable 1 }
OcnEntry ::= SEQUENCE { ocnTypeIdx OcnType,
ocnShelfIdx INTEGER,
ocnSlotIdx INTEGER,
ocnPortIdx INTEGER,
ocnOpticalPwrReceivedMinTh FixedX10,
ocnOpticalPwrReceivedMaxTh FixedX10,
ocnOpticalPwrTransmittedMinTh FixedX10,
ocnOpticalPwrTransmittedMaxTh FixedX10,
ocnOpticalPwrReceived FixedX10,
ocnOpticalPwrTransmitted FixedX10,
ocnBER BERType,
ocnBERTh BERType,
ocnPEC DisplayString,
ocnAdminStatus AdminStatus,
ocnOperStatus OperStatus,
ocnOperStatQlfr OperStatQlfr,
ocnAutoEnableTimer HoursAndMinutes,
ocnActAutoEnableTimer HoursAndMinutes,
ocnWavelength FixedX100,
ocnVendorPN1 DisplayString,
ocnVendorPN2 DisplayString,
ocnVendorPN3 DisplayString,
ocnPhyPMMon INTEGER,
ocnLaserStatus INTEGER,
ocnId1 DisplayString,
ocnFiberType FiberType,
ocnCustom1 DisplayString,
ocnTOHTransparency INTEGER,
ocnLineMapping INTEGER,
ocnProtSwEvtType ProtSwEvtType,
ocnDCCTransparency INTEGER,
ocnTransparencyChannel INTEGER,
ocnRemoteId DisplayString,
ocnRowStatus RowStatus }
ocnTypeIdx OBJECT-TYPE
SYNTAX OcnType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The specific type of OC-N signal which is provisioned."
::= { ocnEntry 1 }
ocnShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the OC-N facility is
provisioned."
::= { ocnEntry 2 }
ocnSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within which the OC-N facility is
provisioned."
::= { ocnEntry 3 }
ocnPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the OC-N
facility is provisioned."
::= { ocnEntry 4 }
ocnOpticalPwrReceivedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received minimum threshold."
::= { ocnEntry 5 }
ocnOpticalPwrReceivedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received maximum threshold."
::= { ocnEntry 6 }
ocnOpticalPwrTransmittedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted minimum threshold."
::= { ocnEntry 7 }
ocnOpticalPwrTransmittedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted maximum threshold."
::= { ocnEntry 8 }
ocnOpticalPwrReceived OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power received on the input of the transceiver."
::= { ocnEntry 9 }
ocnOpticalPwrTransmitted OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power transmitted at the output of the
transceiver."
::= { ocnEntry 10 }
ocnBER OBJECT-TYPE
SYNTAX BERType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The Bit Error Rate measured on the received signal."
::= { ocnEntry 11 }
ocnBERTh OBJECT-TYPE
SYNTAX BERType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Bit Error Rate threshold above which the Signal Degrade
condition is raised."
DEFVAL { tenExpMinus5 }
::= { ocnEntry 12 }
ocnPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned Product Equipment Code used to
validate the physically present optical transceiver on the
OC-N port."
DEFVAL { "" }
::= { ocnEntry 13 }
ocnAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the OC-N facility."
DEFVAL { enabled }
::= { ocnEntry 14 }
ocnOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the OC-N facility."
::= { ocnEntry 15 }
ocnOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the OC-N facility."
::= { ocnEntry 16 }
ocnAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the auto-enable timer for the targeted OC-N
facility. This value only applies if the ocnAdminStatus object
is set to autoEnabled. Otherwise, the value returned is
000-00."
DEFVAL { "008-00" }
::= { ocnEntry 17 }
ocnActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time remaining on the auto-enable timer if it is
actively counting down. Otherwise, the value returned is
000-00."
::= { ocnEntry 18 }
ocnWavelength OBJECT-TYPE
SYNTAX FixedX100
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The wavelength to be transmitted by the transceiver on the
OC-N facility port. This is a mandatory object when a row of
the OC-N table is created."
::= { ocnEntry 19 }
ocnVendorPN1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the OC-N facility port."
DEFVAL { "" }
::= { ocnEntry 20 }
ocnVendorPN2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the OC-N facility port."
DEFVAL { "" }
::= { ocnEntry 21 }
ocnVendorPN3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the OC-N facility port."
DEFVAL { "" }
::= { ocnEntry 22 }
ocnPhyPMMon OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the OC-N facility is configured to report
threshold crossing conditions for physical layer performance
monitoring parameters."
DEFVAL { disabled }
::= { ocnEntry 23 }
ocnLaserStatus OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of the operational status of the transceiver
laser on the OC-N facility port."
::= { ocnEntry 24 }
ocnId1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
OC-N facility in a manner useful to the user."
DEFVAL { "" }
::= { ocnEntry 25 }
ocnFiberType OBJECT-TYPE
SYNTAX FiberType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optional specification of the fiber type that interfaces to
the OC-N facility port."
DEFVAL { none }
::= { ocnEntry 26 }
ocnCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { ocnEntry 27 }
ocnTOHTransparency OBJECT-TYPE
SYNTAX INTEGER { yes (1),
no (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to configure whether the transport overhead of the the
SONET OC-N facility is to be handled transparently or if it is
to be terminated and regenerated. This object only applies to
OC-48 client facilities on the 10G MXP circuit pack and the OC-12
and OC-3 client facilities on the 8-port 2.5G MXP circuit pack."
DEFVAL { no }
::= { ocnEntry 28 }
ocnLineMapping OBJECT-TYPE
SYNTAX INTEGER { unmapped (1),
odu1ToOtu2 (2),
otu2 (3),
subOdu1ToOtu1 (4),
otu1 (5) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to configure the OTN configuration of the line port. If
set to unmapped, there is no OTN digital wrapper added to the
OC-192 or OC-48 facility.
The odu1ToOtu2 and otu2 mapping is applicable to OC-192 line
ports as follows:
odu1ToOtu2 - the line port is configured as an OTN digitally
wrapped OTU2 facility containing 4 ODU1 units.
otu2 - the line port is configured as an OTN digitally
wrapped OTU2 facility to which an OC-192 facility is
directly mapped.
The subOdu1ToOtu1 and otu1 mapping is applicable to OC-48 line
ports as follows:
subOdu1ToOtu1 - the line port is configured as an OTN digitally
wrapped ODU1 facility containing 4 sub-ODU1 units.
otu1 - the line port is configured as an OTN digitally wrapped
OTU1 facility to which an OC-48 facility is directly mapped.
This object applies only to the OC-192 line port of the 10G MXP
circuit pack and the OC-48 line port of the 8-port 2.5G circuit pack."
DEFVAL { otu2 }
::= { ocnEntry 29 }
ocnProtSwEvtType OBJECT-TYPE
SYNTAX ProtSwEvtType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates the type of protection switching event that has
occured on an OC-N facility."
::= { ocnEntry 30 }
ocnDCCTransparency OBJECT-TYPE
SYNTAX INTEGER { yes (1),
no (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to configure whether the Data Communications Channel (DCC)
is transported transparently through the circuit pack. Specifically,
this refers to the D1, D2 and D3 section DCC bytes.
This object only applies to OC-48 client facilities on the
10G MXP circuit pack and the OC-12 client facilities on the
8-port 2.5G MXP circuit pack."
DEFVAL { no }
::= { ocnEntry 31 }
ocnTransparencyChannel OBJECT-TYPE
SYNTAX INTEGER (1..48)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to configure the STS1 channel number on which the DCC
is transported. This object only applies to OC-48 client facilities
on the 10G MXP circuit pack and the OC-12 client facilities on the
8-port 2.5G MXP circuit pack."
DEFVAL { 1 }
::= { ocnEntry 32 }
ocnRemoteId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Identifies the remote node and port to which the
OC-n port is connected, in the format prescribed
by the PSM network management system."
DEFVAL { "" }
::= { ocnEntry 33 }
ocnRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
OC-N table, which in turn controls provisioning and
deprovisioning of OC-N facilities."
::= { ocnEntry 100 }
-----------------------------------------------------------------------
-- Objects related to created SONET STS-N facilities on
-- Muxponder Circuit Packs
--
-- A listing of SONET STS-N path entities that are created on the
-- BTI 7000 Series system. STS-1 path facilities are employed on the
-- SONET version of the Dual GbE Muxponder circuit pack. Only STS-1
-- paths involved in protected VCG configurations on the muxponder card
-- are listed in the stsnTable.
--
-- The following table lists the objects in each entry of the
-- stsnTable.
-----------------------------------------------------------------------
stsnTable OBJECT-TYPE
SYNTAX SEQUENCE OF StsnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every created SONET STS-N
facility on the system. Each row contains a list of attributes
that pertain to the facility."
::= { facilities 6 }
stsnEntry OBJECT-TYPE
SYNTAX StsnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the STS-N table."
INDEX { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx }
::= { stsnTable 1 }
StsnEntry ::= SEQUENCE { stsnTypeIdx StsnType,
stsnShelfIdx INTEGER,
stsnSlotIdx INTEGER,
stsnPortIdx INTEGER,
stsnIdx INTEGER,
stsnProtSwEvtType ProtSwEvtType,
stsnBER BERType,
stsnBERTh BERType,
stsnProtSwStatus OperStatQlfr }
stsnTypeIdx OBJECT-TYPE
SYNTAX StsnType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The specific type of STS-N signal which is created."
::= { stsnEntry 1 }
stsnShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the STS-N facility exists."
::= { stsnEntry 2 }
stsnSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within which the STS-N facility
exists."
::= { stsnEntry 3 }
stsnPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the STS-N
facility exists."
::= { stsnEntry 4 }
stsnIdx OBJECT-TYPE
SYNTAX INTEGER (1..192)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The stsn channel number within the port in which the STS-N
facility exists."
::= { stsnEntry 5 }
stsnProtSwEvtType OBJECT-TYPE
SYNTAX ProtSwEvtType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates the type of protection switching event that has
occured on an STS-N facility."
::= { stsnEntry 6 }
stsnBER OBJECT-TYPE
SYNTAX BERType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The Bit Error Rate measured on the received channel."
::= { stsnEntry 7 }
stsnBERTh OBJECT-TYPE
SYNTAX BERType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The Bit Error Rate threshold above which the Signal Degrade
condition is raised."
::= { stsnEntry 8 }
stsnProtSwStatus OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "If the STS-N facility is configured as part of a protection
grouping, this object indicates its protection status."
::= { stsnEntry 9 }
-----------------------------------------------------------------------
-- Objects related to provisioned SDH STM-N facilities on
-- Muxponder Circuit Packs
--
-- A listing of provisioned SDH STM-N ports is contained in the
-- stmnTable of the BTI 7000 Series MIB. When retrieved, this table
-- includes one row for each provisioned SDH STM-N port facility,
-- which includes STM-16 and STM-64 facilities.
--
-- Note: The stmnTable manages STM-N facilities on muxponder circuit
-- packs, and is not used for wavelength conversion type circuit packs.
-- For management of these facilities, the xcvrTable is used.
--
-- To manually provision an STM-16 or STM-64 facility, a row must be
-- created in the stmnTable. To deprovision an STM-N facility, its row
-- must be destroyed.
--
-- The following table lists the objects in each entry of the
-- stmnTable.
-----------------------------------------------------------------------
stmnTable OBJECT-TYPE
SYNTAX SEQUENCE OF StmnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned SDH STM-N
facility on the system. Each row contains a list of attributes
that pertain to the facility."
::= { facilities 7 }
stmnEntry OBJECT-TYPE
SYNTAX StmnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the STM-N table."
INDEX { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx }
::= { stmnTable 1 }
StmnEntry ::= SEQUENCE { stmnTypeIdx StmnType,
stmnShelfIdx INTEGER,
stmnSlotIdx INTEGER,
stmnPortIdx INTEGER,
stmnOpticalPwrReceivedMinTh FixedX10,
stmnOpticalPwrReceivedMaxTh FixedX10,
stmnOpticalPwrTransmittedMinTh FixedX10,
stmnOpticalPwrTransmittedMaxTh FixedX10,
stmnOpticalPwrReceived FixedX10,
stmnOpticalPwrTransmitted FixedX10,
stmnBER BERType,
stmnBERTh BERType,
stmnPEC DisplayString,
stmnAdminStatus AdminStatus,
stmnOperStatus OperStatus,
stmnOperStatQlfr OperStatQlfr,
stmnAutoEnableTimer HoursAndMinutes,
stmnActAutoEnableTimer HoursAndMinutes,
stmnWavelength FixedX100,
stmnVendorPN1 DisplayString,
stmnVendorPN2 DisplayString,
stmnVendorPN3 DisplayString,
stmnPhyPMMon INTEGER,
stmnLaserStatus INTEGER,
stmnId1 DisplayString,
stmnFiberType FiberType,
stmnCustom1 DisplayString,
stmnTOHTransparency INTEGER,
stmnLineMapping INTEGER,
stmnProtSwEvtType ProtSwEvtType,
stmnDCCTransparency INTEGER,
stmnTransparencyChannel INTEGER,
stmnRemoteId DisplayString,
stmnRowStatus RowStatus }
stmnTypeIdx OBJECT-TYPE
SYNTAX StmnType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The specific type of STM-N signal which is provisioned."
::= { stmnEntry 1 }
stmnShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the STM-N facility is
provisioned."
::= { stmnEntry 2 }
stmnSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within which the STM-N facility is
provisioned."
::= { stmnEntry 3 }
stmnPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the STM-N
facility is provisioned."
::= { stmnEntry 4 }
stmnOpticalPwrReceivedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received minimum threshold."
::= { stmnEntry 5 }
stmnOpticalPwrReceivedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received maximum threshold."
::= { stmnEntry 6 }
stmnOpticalPwrTransmittedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted minimum threshold."
::= { stmnEntry 7 }
stmnOpticalPwrTransmittedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted maximum threshold."
::= { stmnEntry 8 }
stmnOpticalPwrReceived OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power received on the input of the transceiver."
::= { stmnEntry 9 }
stmnOpticalPwrTransmitted OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power transmitted at the output of the
transceiver."
::= { stmnEntry 10 }
stmnBER OBJECT-TYPE
SYNTAX BERType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The Bit Error Rate measured on the received signal."
::= { stmnEntry 11 }
stmnBERTh OBJECT-TYPE
SYNTAX BERType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Bit Error Rate threshold above which the Signal Degrade
condition is raised."
DEFVAL { tenExpMinus6 }
::= { stmnEntry 12 }
stmnPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned Product Equipment Code used to
validate the physically present optical transceiver on the
STM-N port."
DEFVAL { "" }
::= { stmnEntry 13 }
stmnAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the STM-N facility."
DEFVAL { enabled }
::= { stmnEntry 14 }
stmnOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the STM-N facility."
::= { stmnEntry 15 }
stmnOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the STM-N facility."
::= { stmnEntry 16 }
stmnAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the auto-enable timer for the targeted STM-N
facility. This value only applies if the stmnAdminStatus
object is set to autoEnabled. Otherwise, the value returned is
000-00."
DEFVAL { "008-00" }
::= { stmnEntry 17 }
stmnActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time remaining on the auto-enable timer if it is
actively counting down. Otherwise, the value returned is
000-00."
::= { stmnEntry 18 }
stmnWavelength OBJECT-TYPE
SYNTAX FixedX100
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The wavelength to be transmitted by the transceiver on the
STM-N facility port. This is a mandatory object when a row of
the STM-N table is created."
::= { stmnEntry 19 }
stmnVendorPN1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the STM-N facility port."
DEFVAL { "" }
::= { stmnEntry 20 }
stmnVendorPN2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the STM-N facility port."
DEFVAL { "" }
::= { stmnEntry 21 }
stmnVendorPN3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the STM-N facility port."
DEFVAL { "" }
::= { stmnEntry 22 }
stmnPhyPMMon OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the STM-N facility is configured to report
threshold crossing conditions for physical layer performance
monitoring parameters."
DEFVAL { disabled }
::= { stmnEntry 23 }
stmnLaserStatus OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of the operational status of the transceiver
laser on the STM-N facility port."
::= { stmnEntry 24 }
stmnId1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
STM-N facility in a manner useful to the user."
DEFVAL { "" }
::= { stmnEntry 25 }
stmnFiberType OBJECT-TYPE
SYNTAX FiberType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optional specification of the fiber type that interfaces to
the STM-N facility port."
DEFVAL { none }
::= { stmnEntry 26 }
stmnCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { stmnEntry 27 }
stmnTOHTransparency OBJECT-TYPE
SYNTAX INTEGER { yes (1),
no (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to configure whether the transport overhead of the the
SDH STM-N facility is to be handled transparently or if it is
to be terminated and regenerated. This object only applies to
STM-16 client facilities on the 10G MXP circuit pack and the STM-4
and STM-1 client facilities on the 8-port 2.5G MXP circuit pack."
DEFVAL { no }
::= { stmnEntry 28 }
stmnLineMapping OBJECT-TYPE
SYNTAX INTEGER { unmapped (1),
odu1ToOtu2 (2),
otu2 (3),
subOdu1ToOtu1 (4),
otu1 (5) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to configure the OTN configuration of the line port. If
set to unmapped, there is no OTN digital wrapper added to the
STM-64 or STM-16 facility.
The odu1ToOtu2 and otu2 mapping is applicable to STM-64 line
ports as follows:
odu1ToOtu2 - the line port is configured as an OTN digitally
wrapped OTU2 facility containing 4 ODU1 units.
otu2 - the line port is configured as an OTN digitally
wrapped OTU2 facility to which an STM-64 facility is
directly mapped.
The subOdu1ToOtu1 and otu1 mapping is applicable to STM-16 line
ports as follows:
subOdu1ToOtu1 - the line port is configured as an OTN digitally
wrapped ODU1 facility containing 4 sub-ODU1 units.
otu1 - the line port is configured as an OTN digitally wrapped
OTU1 facility to which an STM-16 facility is directly mapped.
This object applies only to the STM-64 line port of the 10G MXP
circuit pack and the STM-16 line port of the 8-port 2.5G circuit pack."
DEFVAL { otu2 }
::= { stmnEntry 29 }
stmnProtSwEvtType OBJECT-TYPE
SYNTAX ProtSwEvtType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates the type of protection switching event that has
occured on an STM-N facility."
::= { stmnEntry 30 }
stmnDCCTransparency OBJECT-TYPE
SYNTAX INTEGER { yes (1),
no (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to configure whether the Data Communications Channel (DCC)
is transported transparently through the circuit pack. Specifically,
this refers to the D1, D2 and D3 section DCC bytes.
This object only applies to STM-16 client facilities on the
10G MXP circuit pack and the STM-4 client facilities on the
8-port 2.5G MXP circuit pack."
DEFVAL { no }
::= { stmnEntry 31 }
stmnTransparencyChannel OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to configure the VC4 channel number on which the DCC
is transported. This object only applies to STM-16 client facilities
on the 10G MXP circuit pack and the STM-4 client facilities on the
8-port 2.5G MXP circuit pack."
DEFVAL { 1 }
::= { stmnEntry 32 }
stmnRemoteId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Identifies the remote node and port to which the
STM-n port is connected, in the format prescribed
by the PSM network management system."
DEFVAL { "" }
::= { stmnEntry 33 }
stmnRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
STM-N table, which in turn controls provisioning and
deprovisioning of STM-N facilities."
::= { stmnEntry 100 }
-----------------------------------------------------------------------
-- Objects related to created SDH VC-N facilities on
-- Muxponder Circuit Packs
--
-- The vcnTable lists the SDH VC-N path entities that are created on
-- the BTI 7000 Series system. VC4 path facilities are employed on SDH
-- versions of the Dual GbE Muxponder circuit pack.
--
-- Only VC4 paths involved in protected VCG configurations on the
-- muxponder card are listed in the stsnTable.
--
-- The following table lists the objects in each entry of the vcnTable.
-----------------------------------------------------------------------
vcnTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every created SDH VC-N
facility on the system. Each row contains a list of attributes
that pertain to the facility."
::= { facilities 8 }
vcnEntry OBJECT-TYPE
SYNTAX VcnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the VC-N table."
INDEX { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx }
::= { vcnTable 1 }
VcnEntry ::= SEQUENCE { vcnTypeIdx VcnType,
vcnShelfIdx INTEGER,
vcnSlotIdx INTEGER,
vcnPortIdx INTEGER,
vcnIdx INTEGER,
vcnProtSwEvtType ProtSwEvtType,
vcnBER BERType,
vcnBERTh BERType,
vcnProtSwStatus OperStatQlfr }
vcnTypeIdx OBJECT-TYPE
SYNTAX VcnType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The specific type of VC-N signal which is created."
::= { vcnEntry 1 }
vcnShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the VC-N facility exists."
::= { vcnEntry 2 }
vcnSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within which the VC-N facility exists."
::= { vcnEntry 3 }
vcnPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the VC-N
facility exists."
::= { vcnEntry 4 }
vcnIdx OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The vcn channel number within the port in which the VC-N
facility exists."
::= { vcnEntry 5 }
vcnProtSwEvtType OBJECT-TYPE
SYNTAX ProtSwEvtType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates the type of protection switching event that has
occured on a VC-N facility."
::= { vcnEntry 6 }
vcnBER OBJECT-TYPE
SYNTAX BERType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The Bit Error Rate measured on the received channel."
::= { vcnEntry 7 }
vcnBERTh OBJECT-TYPE
SYNTAX BERType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The Bit Error Rate threshold above which the Signal Degrade
condition is raised."
::= { vcnEntry 8 }
vcnProtSwStatus OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "If the VC-N facility is configured as part of a protection
grouping, this object indicates its protection status."
::= { vcnEntry 9 }
-----------------------------------------------------------------------
-- Objects related to provisioned Gigabit Ethernet (GE) facilities on
-- Muxponder Circuit Packs
--
-- A listing of provisioned Gigabit Ethernet facilities is contained
-- in the geTable ofthe BTI 7000 Series MIB. When retrieved, this table
-- includes one row for each provisioned Gigabit Ethernet port
-- facility.
--
-- Note: The geTable manages Gigabit Ethernet facilities on muxponder
-- circuit packs, and is not used for wavelength conversion type circuit
-- packs. For management of these facilities, the xcvrTable is used.
--
-- To manually provision a Gigabit Ethernet facility, a row must be
-- created in the geTable. To deprovision a Gigabit Ethernet facility,
-- its row must be destroyed.
--
-- The following table lists the objects in each entry of the geTable.
-----------------------------------------------------------------------
geTable OBJECT-TYPE
SYNTAX SEQUENCE OF GeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned Gigabit
Ethernet (GE) facility on the system. Each row contains a list
of attributes that pertain to the facility."
::= { facilities 9 }
geEntry OBJECT-TYPE
SYNTAX GeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the GE table."
INDEX { geShelfIdx,
geSlotIdx,
gePortIdx }
::= { geTable 1 }
GeEntry ::= SEQUENCE { geShelfIdx INTEGER,
geSlotIdx INTEGER,
gePortIdx INTEGER,
geOpticalPwrReceivedMinTh FixedX10,
geOpticalPwrReceivedMaxTh FixedX10,
geOpticalPwrTransmittedMinTh FixedX10,
geOpticalPwrTransmittedMaxTh FixedX10,
geOpticalPwrReceived FixedX10,
geOpticalPwrTransmitted FixedX10,
gePEC DisplayString,
geAdminStatus AdminStatus,
geOperStatus OperStatus,
geOperStatQlfr OperStatQlfr,
geAutoEnableTimer HoursAndMinutes,
geActAutoEnableTimer HoursAndMinutes,
geWavelength FixedX100,
geVendorPN1 DisplayString,
geVendorPN2 DisplayString,
geVendorPN3 DisplayString,
gePhyPMMon INTEGER,
geFPSD INTEGER,
geLaserStatus INTEGER,
geId1 DisplayString,
geFiberType FiberType,
geCustom1 DisplayString,
geSpeed Gauge32,
geDuplex DuplexModeType,
geMediaRate MediaRateType,
geMTU Integer32,
geMACAddr MacAddress,
geGfpMode INTEGER,
geFlowControl INTEGER,
geRemoteId DisplayString,
geRowStatus RowStatus }
geShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the GE facility is
provisioned."
::= { geEntry 1 }
geSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within which the GE facility is
provisioned."
::= { geEntry 2 }
gePortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the GE
facility is provisioned."
::= { geEntry 3 }
geOpticalPwrReceivedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received minimum threshold."
::= { geEntry 4 }
geOpticalPwrReceivedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received maximum threshold."
::= { geEntry 5 }
geOpticalPwrTransmittedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted minimum threshold."
::= { geEntry 6 }
geOpticalPwrTransmittedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted maximum threshold."
::= { geEntry 7 }
geOpticalPwrReceived OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power received on the input of the transceiver."
::= { geEntry 8 }
geOpticalPwrTransmitted OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power transmitted at the output of the
transceiver."
::= { geEntry 9 }
gePEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned transceiver Product Equipment Code
used to validate the physically present transceiver on the
Gigabit Ethernet port."
DEFVAL { "" }
::= { geEntry 10 }
geAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the Gigabit Ethernet facility."
DEFVAL { enabled }
::= { geEntry 11 }
geOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the Gigabit Ethernet
facility."
::= { geEntry 12 }
geOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the Gigabit Ethernet facility."
::= { geEntry 13 }
geAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the auto-enable timer for the targeted Gigabit
Ethernet facility. This value only applies if the
geAdminStatus object is set to autoEnabled. Otherwise, the
value returned is 000-00."
DEFVAL { "008-00" }
::= { geEntry 14 }
geActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time remaining on the auto-enable timer if it is
actively counting down. Otherwise, the value returned is
000-00."
::= { geEntry 15 }
geWavelength OBJECT-TYPE
SYNTAX FixedX100
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The wavelength to be transmitted by the transceiver on the
Gigabit Ethernet facility port. This is a mandatory object
when a row of the Gigabit Ethernet table is created."
::= { geEntry 16 }
geVendorPN1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the Gigabit Ethernet facility port."
DEFVAL { "" }
::= { geEntry 17 }
geVendorPN2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the Gigabit Ethernet facility port."
DEFVAL { "" }
::= { geEntry 18 }
geVendorPN3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the Gigabit Ethernet facility port."
DEFVAL { "" }
::= { geEntry 19 }
gePhyPMMon OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the Gigabit Ethernet facility is configured to
report threshold crossing conditions for physical layer
performance monitoring parameters."
DEFVAL { disabled }
::= { geEntry 20 }
geFPSD OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the Gigabit Ethernet facility is configured for
Fault Propagation Shut Down."
DEFVAL { disabled }
::= { geEntry 21 }
geLaserStatus OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of the operational status of the transceiver
laser on the Gigabit Ethernet facility port."
::= { geEntry 22 }
geId1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
Gigabit Ethernet facility in a manner useful to the user."
DEFVAL { "" }
::= { geEntry 23 }
geFiberType OBJECT-TYPE
SYNTAX FiberType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optional specification of the fiber type that interfaces to
the Gigabit Ethernet facility port."
DEFVAL { none }
::= { geEntry 24 }
geCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { geEntry 25 }
geSpeed OBJECT-TYPE
SYNTAX Gauge32
UNITS "Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The speed of the Gigabit Ethernet facility link."
::= { geEntry 26 }
geDuplex OBJECT-TYPE
SYNTAX DuplexModeType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The duplex mode of the Gigabit Ethernet facility interface."
::= { geEntry 27 }
geMediaRate OBJECT-TYPE
SYNTAX MediaRateType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The configured media rate of the Gigabit Ethernet facility
interface."
DEFVAL { autoNegotiated }
::= { geEntry 28 }
geMTU OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MTU size for the Gigabit Ethernet facility interface."
::= { geEntry 29 }
geMACAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of the Gigabit Ethernet facility interface."
::= { geEntry 30 }
geGfpMode OBJECT-TYPE
SYNTAX INTEGER { unmapped (1),
gfpf (2), -- GFP - Framed
gfpt (3) } -- GFP - Transparent
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Configures the mapping of GE facility port onto the line port
using either framed or transparent general framing protocol."
DEFVAL { gfpt }
::= { geEntry 31 }
geFlowControl OBJECT-TYPE
SYNTAX INTEGER { transparent (1),
local (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Configures the flow control setting of GE facility as
transparent or locally enabled."
DEFVAL { transparent }
::= { geEntry 32 }
geRemoteId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Identifies the remote node and port to which the
gigabit ethernet port is connected, in the format
prescribed by the PSM network management system."
DEFVAL { "" }
::= { geEntry 33 }
geRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
Gigabit Ethernet table, which in turn controls provisioning
and deprovisioning of Gigabit Ethernet facilities."
::= { geEntry 100 }
-----------------------------------------------------------------------
-- Objects related to provisioned Fast Ethernet (FE) facilities on
-- Muxponder Circuit Packs
--
-- A listing of provisioned Fast Ethernet facilities is contained in
-- the feTable of the BTI 7000 Series MIB. When retrieved, this table
-- includes one row for each provisioned Fast Ethernet port facility.
--
-- To manually provision a Fast Ethernet facility, a row must be
-- created in the feTable. To deprovision a Fast Ethernet facility,
-- its row must be destroyed.
--
-- The following table lists the objects in each entry of the feTable.
-----------------------------------------------------------------------
feTable OBJECT-TYPE
SYNTAX SEQUENCE OF FeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned Fast
Ethernet (FE) facility on the system. Each row contains a list
of attributes that pertain to the facility."
::= { facilities 10 }
feEntry OBJECT-TYPE
SYNTAX FeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the FE table."
INDEX { feShelfIdx,
feSlotIdx,
fePortIdx }
::= { feTable 1 }
FeEntry ::= SEQUENCE { feShelfIdx INTEGER,
feSlotIdx INTEGER,
fePortIdx INTEGER,
feId1 DisplayString,
feCustom1 DisplayString,
feSpeed Gauge32,
feDuplex DuplexModeType,
feMediaRate MediaRateType,
feMTU Integer32,
feMACAddr MacAddress,
feRemoteId DisplayString,
feRowStatus RowStatus }
feShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the FE facility is
provisioned."
::= { feEntry 1 }
feSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within which the FE facility is
provisioned."
::= { feEntry 2 }
fePortIdx OBJECT-TYPE
SYNTAX INTEGER (5..6)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the FE
facility is provisioned."
::= { feEntry 3 }
feId1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
Fast Ethernet facility in a manner useful to the user."
DEFVAL { "" }
::= { feEntry 4 }
feCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { feEntry 5 }
feSpeed OBJECT-TYPE
SYNTAX Gauge32
UNITS "Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The speed of the Fast Ethernet facility link."
::= { feEntry 6 }
feDuplex OBJECT-TYPE
SYNTAX DuplexModeType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The duplex mode of the Fast Ethernet facility interface."
::= { feEntry 7 }
feMediaRate OBJECT-TYPE
SYNTAX MediaRateType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The configured media rate of the Fast Ethernet facility
interface."
::= { feEntry 8 }
feMTU OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MTU size for the Fast Ethernet facility interface."
::= { feEntry 9 }
feMACAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of the Fast Ethernet facility interface."
::= { feEntry 10 }
feRemoteId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Identifies the remote node and port to which the
fast ethernet port is connected, in the format
prescribed by the PSM network management system."
DEFVAL { "" }
::= { feEntry 11 }
feRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
Fast Ethernet table, which in turn controls provisioning and
deprovisioning of Fast Ethernet facilities."
::= { feEntry 100 }
-----------------------------------------------------------------------
-- Objects related to VCG entities on Muxponder Circuit Packs
--
-- A listing of Virtual Concatenation Group (VCG) entities is
-- contained in the vcgTable of the BTI 7000 Series MIB. When retrieved,
-- this table includes one row for each created VCG. VCG entities are
-- created on muxponder circuit packs to facilitate cross connect
-- management.
--
-- All VCGs are created and deleted automatically as a result of the
-- creation and deletion of the supporting entity in the ocnTable or the
-- stmnTable. The following table lists the objects in each entry of the
-- vcgTable.
-----------------------------------------------------------------------
vcgTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned Virtual
Concatenation Group (VCG) enitity on the system. Each row
contains a list of attributes that pertain to the VCG."
::= { facilities 11 }
vcgEntry OBJECT-TYPE
SYNTAX VcgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the VCG table."
INDEX { vcgShelfIdx,
vcgSlotIdx,
vcgPortIdx,
vcgIdx }
::= { vcgTable 1 }
VcgEntry ::= SEQUENCE { vcgShelfIdx INTEGER,
vcgSlotIdx INTEGER,
vcgPortIdx INTEGER,
vcgIdx INTEGER,
vcgType INTEGER,
vcgTimeSlotIndices DisplayString,
vcgRowStatus RowStatus }
vcgShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the VCG entity is located."
::= { vcgEntry 1 }
vcgSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the VCG entity is
located."
::= { vcgEntry 2 }
vcgPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the VCG
entity is located."
::= { vcgEntry 3 }
vcgIdx OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the VCG within the identified port."
::= { vcgEntry 4 }
vcgType OBJECT-TYPE
SYNTAX INTEGER { sts1c21v (1),
sts1c2v (2),
sts3c7v (3),
sts3c1v (4),
vc47v (5),
vc41v (6),
sts1c3v (7),
sts1c19v (8),
sts1c22v (9),
sts1c37v (10),
sts1c74v (11),
sts3c6v (12),
sts3c12v (13),
sts3c24v (14),
vc46v (15),
vc412v (16),
vc424v (17),
vc42v (18),
sts1c6v (19),
sts3c2v (20),
sts1c31v (21),
sts3c10v (22),
vc410v (23) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The format of the VCG."
::= { vcgEntry 5 }
vcgTimeSlotIndices OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..511))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A textual listing of the time slot indices used for the VCG.
The information is formatted as a comma-separated list of of
individual time slot indices or time slot index ranges. For
example, a value of 'X-Y,Z' indicates that the VCG includes
all time slots in the range of X to Y, plus Z, when X, Y, and
Z are all integers."
::= { vcgEntry 6 }
vcgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
VCG table, which in turn controls provisioning and
deprovisioning of Virtual Concatenation groups. Manual
creation and deletion of VCGs is supported only on the 10G
MXP, as all VCGs on the 2.5G MXP are auto-created and
deleted."
::= { vcgEntry 100 }
-----------------------------------------------------------------------
-- Objects related to provisioned fiber channel facilities on
-- Muxponder Circuit Packs
--
-- A listing of provisioned Fibre Channel facilities is contained in
-- the fcTable of the BTI 7000 Series MIB. When retrieved, this table
-- includes one row for each provisioned Fibre Channel port facility.
--
-- Note: The fcTable manages Fibre Channel facilities on muxponder
-- circuit packs, and is not used for wavelength conversion type
-- circuit packs. For management of these facilities, the xcvrTable
-- is used.
--
-- To manually provision a Fibre Channel facility, a row must be
-- created in the fcTable. To deprovision a Fibre Channel facility,
-- its row must be destroyed.
--
-- The following table lists the objects in each entry of the fcTable.
-----------------------------------------------------------------------
fcTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned fiber
channel facility on the system. Each row contains a list of
attributes that pertain to the facility."
::= { facilities 12 }
fcEntry OBJECT-TYPE
SYNTAX FcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the fiber channel table."
INDEX { fcShelfIdx,
fcSlotIdx,
fcPortIdx }
::= { fcTable 1 }
FcEntry ::= SEQUENCE { fcShelfIdx INTEGER,
fcSlotIdx INTEGER,
fcPortIdx INTEGER,
fcRate INTEGER,
fcOpticalPwrReceivedMinTh FixedX10,
fcOpticalPwrReceivedMaxTh FixedX10,
fcOpticalPwrTransmittedMinTh FixedX10,
fcOpticalPwrTransmittedMaxTh FixedX10,
fcOpticalPwrReceived FixedX10,
fcOpticalPwrTransmitted FixedX10,
fcPEC DisplayString,
fcAdminStatus AdminStatus,
fcOperStatus OperStatus,
fcOperStatQlfr OperStatQlfr,
fcAutoEnableTimer HoursAndMinutes,
fcActAutoEnableTimer HoursAndMinutes,
fcWavelength FixedX100,
fcVendorPN1 DisplayString,
fcVendorPN2 DisplayString,
fcVendorPN3 DisplayString,
fcPhyPMMon INTEGER,
fcFPSD INTEGER,
fcLaserStatus INTEGER,
fcId1 DisplayString,
fcFiberType FiberType,
fcCustom1 DisplayString,
fcGfpMode INTEGER,
fcRemoteId DisplayString,
fcRowStatus RowStatus }
fcShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the fiber channel facility is
provisioned."
::= { fcEntry 1 }
fcSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within which the fiber channel facility
is provisioned."
::= { fcEntry 2 }
fcPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the fiber
channel facility is provisioned."
::= { fcEntry 3 }
fcRate OBJECT-TYPE
SYNTAX INTEGER { oneGbs (1),
twoGbs (2),
fourGbs (3) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The rate of the fiber channel signal which is provisioned."
::= { fcEntry 4 }
fcOpticalPwrReceivedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received minimum threshold."
::= { fcEntry 5 }
fcOpticalPwrReceivedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received maximum threshold."
::= { fcEntry 6 }
fcOpticalPwrTransmittedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted minimum threshold."
::= { fcEntry 7 }
fcOpticalPwrTransmittedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted maximum threshold."
::= { fcEntry 8 }
fcOpticalPwrReceived OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power received on the input of the transceiver."
::= { fcEntry 9 }
fcOpticalPwrTransmitted OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power transmitted at the output of the
transceiver."
::= { fcEntry 10 }
fcPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned Product Equipment Code used to
validate the physically present optical transceiver on the
fiber channel port."
DEFVAL { "" }
::= { fcEntry 11 }
fcAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the fiber channel facility."
DEFVAL { enabled }
::= { fcEntry 12 }
fcOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the fiber channel
facility."
::= { fcEntry 13 }
fcOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the fiber channel facility."
::= { fcEntry 14 }
fcAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the auto-enable timer for the targeted fiber channel
facility. This value only applies if the fcAdminStatus object
is set to autoEnabled. Otherwise, the value returned is
000-00."
DEFVAL { "008-00" }
::= { fcEntry 15 }
fcActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time remaining on the auto-enable timer if it is
actively counting down. Otherwise, the value returned is
000-00."
::= { fcEntry 16 }
fcWavelength OBJECT-TYPE
SYNTAX FixedX100
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The wavelength to be transmitted by the transceiver on the
fiber channel facility port. This is a mandatory object when a
row of the fiber channel table is created."
::= { fcEntry 17 }
fcVendorPN1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the fiber channel facility port."
DEFVAL { "" }
::= { fcEntry 18 }
fcVendorPN2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the fiber channel facility port."
DEFVAL { "" }
::= { fcEntry 19 }
fcVendorPN3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the fiber channel facility port."
DEFVAL { "" }
::= { fcEntry 20 }
fcPhyPMMon OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the fiber channel facility is configured to
report threshold crossing conditions for physical layer
performance monitoring parameters."
DEFVAL { disabled }
::= { fcEntry 21 }
fcFPSD OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the Fiber Channel facility is configured for
Fault Propagation Shut Down."
DEFVAL { disabled }
::= { fcEntry 22 }
fcLaserStatus OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of the operational status of the transceiver
laser on the fiber channel facility port."
::= { fcEntry 23 }
fcId1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
fiber channel facility in a manner useful to the user."
DEFVAL { "" }
::= { fcEntry 24 }
fcFiberType OBJECT-TYPE
SYNTAX FiberType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optional specification of the fiber type that interfaces to
the fiber channel facility port."
DEFVAL { none }
::= { fcEntry 25 }
fcCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { fcEntry 26 }
fcGfpMode OBJECT-TYPE
SYNTAX INTEGER { unmapped (1),
gfpt (2) } -- GFP - Transparent
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Configures the mapping of fiber channel facility port onto the
line port using GFP. Only the transparent mapping is supported
for fiber channel facilities."
DEFVAL { gfpt }
::= { fcEntry 27 }
fcRemoteId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Identifies the remote node and port to which the
fiber channel port is connected, in the format
prescribed by the PSM network management system."
DEFVAL { "" }
::= { fcEntry 28 }
fcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
fiber channel table, which in turn controls provisioning and
deprovisioning of fiber channel facilities."
::= { fcEntry 100 }
-----------------------------------------------------------------------
-- Objects related to Optical Service Channel entities
-- on the system
--
-- A listing of provisioned optical supervisory channel (OSC)
-- facilities is contained in the oscTable of the BTI 7000 Series MIB.
-- When retrieved, this table provides one row for each provisioned OSC
-- interface. There is up to two entries in this table.
--
-- The following table lists the objects in each entry of the oscTable.
-----------------------------------------------------------------------
oscTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned optical
supervisory channel interface on the NE. Each row contains a
list of attributes that pertain to the OSC."
::= { dataComms 1 }
oscEntry OBJECT-TYPE
SYNTAX OscEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical supervisory channel
table."
INDEX { oscShelfIdx,
oscSlotIdx,
oscIdx }
::= { oscTable 1 }
OscEntry ::= SEQUENCE { oscShelfIdx INTEGER,
oscSlotIdx INTEGER,
oscIdx INTEGER,
oscAdminStatus AdminStatus,
oscOperStatus OperStatus,
oscOperStatQlfr OperStatQlfr,
oscCustom1 DisplayString,
oscType INTEGER,
oscUnmbrd TruthValue,
oscSpeed Gauge32,
oscDuplex DuplexModeType,
oscMediaRate MediaRateType,
oscMTU Integer32,
oscMACAddr MacAddress,
oscIPAddr IpAddress,
oscIPMask IpAddress,
oscIPBcast IpAddress,
oscRowStatus RowStatus }
oscShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the OSC is provisioned."
::= { oscEntry 1 }
oscSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot in which the OSC is provisioned."
::= { oscEntry 2 }
oscIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the OSC is
provisioned."
::= { oscEntry 3 }
oscAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the OSC interface."
DEFVAL { enabled }
::= { oscEntry 4 }
oscOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the OSC interface."
::= { oscEntry 5 }
oscOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual list of qualifiers for the reported operational
status of the OSC interface."
::= { oscEntry 6 }
oscCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { oscEntry 7 }
oscType OBJECT-TYPE
SYNTAX INTEGER { optical (1),
electrical (2),
logical (3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of physical communication medium attached to the OSC
interface."
::= { oscEntry 8 }
oscUnmbrd OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether or not the OSC interface is the type that
requires an IP address to be assigned."
::= { oscEntry 9 }
oscSpeed OBJECT-TYPE
SYNTAX Gauge32
UNITS "Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The speed of the OSC link."
::= { oscEntry 10 }
oscDuplex OBJECT-TYPE
SYNTAX DuplexModeType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The duplex mode of the OSC interface."
::= { oscEntry 11 }
oscMediaRate OBJECT-TYPE
SYNTAX MediaRateType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The configured media rate of the OSC interface."
::= { oscEntry 12 }
oscMTU OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MTU size for the OSC interface."
::= { oscEntry 13 }
oscMACAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of the OSC interface."
::= { oscEntry 14 }
oscIPAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The IP Address of the OSC interface. A value of 0.0.0.0
indicates that the interface is not assigned an IP address."
::= { oscEntry 15 }
oscIPMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The IP Subnet Mask of the OSC interface."
::= { oscEntry 16 }
oscIPBcast OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP broadcast address of the OSC interface."
::= { oscEntry 17 }
oscRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
OSC table, which in turn controls provisioning and
deprovisioning of OSC interfaces."
::= { oscEntry 100 }
-----------------------------------------------------------------------
-- Objects related to the Network Management Interfaces
-- on the system
--
-- A listing of the network management interface entities on the
-- BTI 7000 Series is contained in the netMgmtTable of the BTI-7000-MIB.
-- When retrieved, this table provides one row for each network
-- management interface. There are two entries in this table:
--
-- <20> one for the network management system (NMS) interface
-- <20> one for the craft interface
--
-- The following table lists the objects in each entry of the
-- netMgmtTable.
-----------------------------------------------------------------------
netMgmtTable OBJECT-TYPE
SYNTAX SEQUENCE OF NetMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every network management
interface on the NE. Each row contains a list of attributes
that pertain to the interface."
::= { dataComms 2 }
netMgmtEntry OBJECT-TYPE
SYNTAX NetMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the network management interface
table."
INDEX { netMgmtIdx }
::= { netMgmtTable 1 }
NetMgmtEntry ::= SEQUENCE { netMgmtIdx INTEGER,
netMgmtAdminStatus AdminStatus,
netMgmtOperStatus OperStatus,
netMgmtOperStatQlfr OperStatQlfr,
netMgmtIPAddr IpAddress,
netMgmtIPMask IpAddress,
netMgmtIPBcast IpAddress,
netMgmtCustom1 DisplayString,
netMgmtType INTEGER,
netMgmtUnmbrd TruthValue,
netMgmtSpeed Gauge32,
netMgmtDuplex DuplexModeType,
netMgmtMediaRate MediaRateType,
netMgmtMTU Integer32,
netMgmtMACAddr MacAddress }
netMgmtIdx OBJECT-TYPE
SYNTAX INTEGER { nms (1),
craft (2) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies the specific management interface."
::= { netMgmtEntry 1 }
netMgmtAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The administrative status of the management interface."
DEFVAL { enabled }
::= { netMgmtEntry 2 }
netMgmtOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the management interface."
::= { netMgmtEntry 3 }
netMgmtOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual list of qualifiers for the reported operational
status of the management interface."
::= { netMgmtEntry 4 }
netMgmtIPAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP Address of the management interface."
::= { netMgmtEntry 5 }
netMgmtIPMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP Subnet Mask of the management interface."
::= { netMgmtEntry 6 }
netMgmtIPBcast OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP broadcast address of the management interface."
::= { netMgmtEntry 7 }
netMgmtCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { netMgmtEntry 8 }
netMgmtType OBJECT-TYPE
SYNTAX INTEGER { optical (1),
electrical (2),
logical (3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of physical communication medium attached to the
management interface."
::= { netMgmtEntry 9 }
netMgmtUnmbrd OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether or not the management interface is the type
that requires an IP address to be assigned."
::= { netMgmtEntry 10 }
netMgmtSpeed OBJECT-TYPE
SYNTAX Gauge32
UNITS "Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The speed of the management interface link."
::= { netMgmtEntry 11 }
netMgmtDuplex OBJECT-TYPE
SYNTAX DuplexModeType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The duplex mode of the management interface."
::= { netMgmtEntry 12 }
netMgmtMediaRate OBJECT-TYPE
SYNTAX MediaRateType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The configured media rate of the management interface."
::= { netMgmtEntry 13 }
netMgmtMTU OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MTU size for this management interface."
::= { netMgmtEntry 14 }
netMgmtMACAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of the management interface."
::= { netMgmtEntry 15 }
-----------------------------------------------------------------------
-- Objects related to serial communications ports
--
-- The serialTable contains a listing of serial communications ports
-- on the BTI 7000 Series that can be used for a management interface
-- to the system. Currently, a single entry is supported in the table
-- for the serial port on the
-- shelf controller circuit pack faceplate.
--
-- The following table lists the objects in each entry of the
-- serialTable.
-----------------------------------------------------------------------
serialTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of serial communication ports on the network element.
Each row contains a list of attributes that pertain to a given
serial port."
::= { dataComms 3 }
serialEntry OBJECT-TYPE
SYNTAX SerialEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object for the serial port table."
INDEX { serialPortIdx }
::= { serialTable 1 }
SerialEntry ::= SEQUENCE { serialPortIdx INTEGER,
serialBaudRate Unsigned32,
serialDataBits INTEGER,
serialParity INTEGER,
serialStopBits INTEGER }
serialPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The serial port instance on the NE."
::= { serialEntry 1 }
serialBaudRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The baud rate of the serial port."
::= { serialEntry 2 }
serialDataBits OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The number of data bits of the serial port."
::= { serialEntry 3 }
serialParity OBJECT-TYPE
SYNTAX INTEGER { none (1),
odd (2),
even (3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The parity value of the serial port."
::= { serialEntry 4 }
serialStopBits OBJECT-TYPE
SYNTAX INTEGER { one (1),
two (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The number of stop bits of the serial port."
::= { serialEntry 5 }
-----------------------------------------------------------------------
-- Objects related to provisioned Ethernet facilities
------------------------------------------------------------------------
ethIntfTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIntfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned Ethernet
facility on the system. Each row contains a list of attributes
that pertain to the facility."
::= { facilities 14 }
ethIntfEntry OBJECT-TYPE
SYNTAX EthIntfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the ethIntfTable table."
INDEX { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx }
::= { ethIntfTable 1 }
EthIntfEntry ::= SEQUENCE { ethIntfShelfIdx INTEGER,
ethIntfSlotIdx INTEGER,
ethIntfPortTypeIdx PvxL1PortType,
ethIntfPortIdx INTEGER,
ethIntfOpticalPwrReceivedMinTh FixedX10,
ethIntfOpticalPwrReceivedMaxTh FixedX10,
ethIntfOpticalPwrTransmittedMinTh FixedX10,
ethIntfOpticalPwrTransmittedMaxTh FixedX10,
ethIntfOpticalPwrReceived FixedX10,
ethIntfOpticalPwrTransmitted FixedX10,
ethIntfPEC DisplayString,
ethIntfAdminStatus AdminStatus,
ethIntfOperStatus OperStatus,
ethIntfOperStatQlfr OperStatQlfr,
ethIntfAutoEnableTimer HoursAndMinutes,
ethIntfActAutoEnableTimer HoursAndMinutes,
ethIntfWavelength FixedX100,
ethIntfVendorPN1 DisplayString,
ethIntfVendorPN2 DisplayString,
ethIntfVendorPN3 DisplayString,
ethIntfPhyPMMon INTEGER,
ethIntfFPSD INTEGER,
ethIntfLaserStatus INTEGER,
ethIntfId1 DisplayString,
ethIntfFiberType FiberType,
ethIntfCustom1 DisplayString,
ethIntfSpeed Gauge32,
ethIntfDuplex INTEGER,
ethIntfMediaRate MediaRateType,
ethIntfMTU INTEGER,
ethIntfLinkStatus INTEGER,
ethIntfLagId INTEGER,
ethIntfLagPortPriority Integer32,
ethIntfBER BERType,
ethIntfMACAddr MacAddress,
ethIntfLineMapping INTEGER,
ethIntfErrorCorrection INTEGER,
ethIntfLpbkOpCmd INTEGER,
ethIntfRemoteId DisplayString,
ethIntfMirrorConfig MirrorConfigType,
ethIntfLldpAdminStatus INTEGER,
ethIntfLldpRemChassisIdSubtype LldpChassisIdSubtype,
ethIntfLldpRemChassisId LldpChassisId,
ethIntfLldpRemPortIdSubtype LldpPortIdSubtype,
ethIntfLldpRemPortId LldpPortId,
ethIntfBouncingStateChangeCount Integer32,
ethIntfRowStatus RowStatus }
ethIntfShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1 | 11 | 21 | 31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf in which the Ethernet facility
resides."
::= { ethIntfEntry 1 }
ethIntfSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot in which the Ethernet facility
resides."
::= { ethIntfEntry 2 }
ethIntfPortTypeIdx OBJECT-TYPE
SYNTAX PvxL1PortType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The type of the port on the circuit pack."
::= {ethIntfEntry 3 }
ethIntfPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
ethernet facility is provisioned."
::= { ethIntfEntry 4 }
ethIntfOpticalPwrReceivedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received minimum threshold."
::= { ethIntfEntry 5 }
ethIntfOpticalPwrReceivedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received maximum threshold."
::= { ethIntfEntry 6 }
ethIntfOpticalPwrTransmittedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted minimum threshold."
::= { ethIntfEntry 7 }
ethIntfOpticalPwrTransmittedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted maximum threshold."
::= { ethIntfEntry 8 }
ethIntfOpticalPwrReceived OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power received on the input of the transceiver."
::= { ethIntfEntry 9 }
ethIntfOpticalPwrTransmitted OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power transmitted at the output of the
transceiver."
::= { ethIntfEntry 10 }
ethIntfPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned transceiver Product Equipment Code
used to validate the physically present transceiver on the
Ethernet port."
DEFVAL { "" }
::= { ethIntfEntry 11 }
ethIntfAdminStatus OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the Ethernet facility."
DEFVAL { enabled }
::= { ethIntfEntry 12 }
ethIntfOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the Ethernet facility."
::= { ethIntfEntry 13 }
ethIntfOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the Ethernet facility."
::= { ethIntfEntry 14 }
ethIntfAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the auto-enable timer for the targeted Ethernet
facility. This value only applies if the AdminStatus object is
set to autoEnabled. Otherwise, the value returned is 000-00."
DEFVAL { "008-00" }
::= { ethIntfEntry 15 }
ethIntfActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time remaining on the auto-enable timer if it is
actively counting down. Otherwise, the value returned is
000-00."
::= { ethIntfEntry 16 }
ethIntfWavelength OBJECT-TYPE
SYNTAX FixedX100
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The wavelength to be transmitted by the transceiver on the
Gigabit Ethernet facility port. This is a mandatory object
when a row of the Ethernet table is created."
::= { ethIntfEntry 17 }
ethIntfVendorPN1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the Ethernet facility port."
DEFVAL { "" }
::= { ethIntfEntry 18 }
ethIntfVendorPN2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the Ethernet facility port."
DEFVAL { "" }
::= { ethIntfEntry 19 }
ethIntfVendorPN3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the Ethernet facility port."
DEFVAL { "" }
::= { ethIntfEntry 20 }
ethIntfPhyPMMon OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the Ethernet facility is configured to report
threshold crossing conditions for physical layer performance
monitoring parameters."
DEFVAL { disabled }
::= { ethIntfEntry 21 }
ethIntfFPSD OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the Ethernet facility is configured for Fault
Propagation Shut Down."
DEFVAL { disabled }
::= { ethIntfEntry 22 }
ethIntfLaserStatus OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of the operational status of the transceiver
laser on the Ethernet facility port."
::= { ethIntfEntry 23 }
ethIntfId1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
facility in a manner useful to the user."
DEFVAL { "" }
::= { ethIntfEntry 24 }
ethIntfFiberType OBJECT-TYPE
SYNTAX FiberType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optional specification of the fiber type that interfaces to
the Ethernet facility port."
DEFVAL { none }
::= { ethIntfEntry 25 }
ethIntfCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { ethIntfEntry 26 }
ethIntfSpeed OBJECT-TYPE
SYNTAX Gauge32
UNITS "Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The speed of the Ethernet facility link. This object is
mandatory to create a new facility and determines the type of
interface, based on speed."
::= { ethIntfEntry 27 }
ethIntfDuplex OBJECT-TYPE
SYNTAX INTEGER { half (1),
full (2),
both (3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The duplex mode of the Ethernet facility interface."
::= { ethIntfEntry 28 }
ethIntfMediaRate OBJECT-TYPE
SYNTAX MediaRateType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The configured media rate of the Ethernet facility interface.
For 10 GE interfaces, the media rate can only be autoNegotiated."
DEFVAL { autoNegotiated }
::= { ethIntfEntry 29 }
ethIntfMTU OBJECT-TYPE
SYNTAX INTEGER (1518..9600)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The MTU size for the Ethernet facility interface."
DEFVAL { 1518 }
::= { ethIntfEntry 30 }
ethIntfLinkStatus OBJECT-TYPE
SYNTAX INTEGER { up (1),
down (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object provides the link status information regarding the
particular interface."
::= { ethIntfEntry 31 }
ethIntfLagId OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object provides the information regarding the LAG Id of
the particular interface."
::= { ethIntfEntry 32 }
ethIntfLagPortPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object provides the information for lag port priority of
the particular interface."
::= { ethIntfEntry 33 }
-- ethIntfEntry 34 DELETED!
ethIntfBER OBJECT-TYPE
SYNTAX BERType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Signal Degrade Bit Error Ratio (SDBER) is used to
configure the error rate threshold above which a Signal
Degrade is declared."
DEFVAL { tenExpMinus5 }
::= { ethIntfEntry 37 }
-- ethIntfEntry 38 DELETED!
ethIntfMACAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of the interface."
::= { ethIntfEntry 39 }
ethIntfLineMapping OBJECT-TYPE
SYNTAX INTEGER { tenglanphy (1),
otu2gfp1 (2),
notApplicable (3),
stacking (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "For 10 GE interfaces, both 10 GE LAN PHY and OTU2 encapsulated
10GE LAN PHY will be supported. The line mapping attribute
allow provisioning of either of the protocol. This attributes
applies to 10 GE interfaces only. When a 10 GE interface is configured
as a stacking port, this field is set to stacking.
NOTE: This parameter does not apply to gigabitEthernet type
interfaces, attempts to set this for gigE port types will fail.
Reading this object for non-10GigE interfaces will return
notApplicable."
DEFVAL { tenglanphy }
::= { ethIntfEntry 40 }
ethIntfErrorCorrection OBJECT-TYPE
SYNTAX INTEGER { none (1),
fec (2),
efec (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "For 10G in OTU2 line-mapping mode, this object specifies
the error correction mode. For interfaces in tenlanphy
line-mapping mode, this object must be none. Attempts to
set it to any other value while in tenglanphy mode will fail.
NOTE: This parameter does not apply to gigabitEthernet type
interfaces, attempts to set this for gigE port types will fail."
DEFVAL { none }
::= { ethIntfEntry 41 }
ethIntfLpbkOpCmd OBJECT-TYPE
SYNTAX INTEGER { noOp (1),
oprLpbk (2),
rlsLpbk (3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a loopback operation on a transceiver facility
as follows:
- oprLpbk: operates a loopback on the transceiver
- rlsLpbk: causes a previously invoked loopback to be released
When read, this object returns noOp."
::= { ethIntfEntry 42 }
ethIntfRemoteId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Identifies the remote node and port to which the
PVX ethernet port is connected, in the format
prescribed by the PSM network management system."
DEFVAL { "" }
::= { ethIntfEntry 43 }
ethIntfMirrorConfig OBJECT-TYPE
SYNTAX MirrorConfigType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Mirror configuration for the physical ethernet port"
DEFVAL { none }
::= { ethIntfEntry 44 }
ethIntfLldpAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The administratively desired status of the local LLDP agent.
If the associated ethIntfLldpAdminStatus object has a
value of 'enabled(1)', then the LLDP agent will transmit
and receive LLDP frames on this port.
If the associated ethIntfLldpAdminStatus object has a
value of 'disabled(2)', then LLDP agent will not transmit or
receive LLDP frames on this port. If there is remote systems
information which is received on this port and stored in
other tables, before the port's ethIntfLldpAdminStatus
becomes disabled, then the information will naturally age out."
-- REFERENCE "IEEE 802.1AB-2005 10.5.1"
DEFVAL { enabled }
::= { ethIntfEntry 45 }
ethIntfLldpRemChassisIdSubtype OBJECT-TYPE
SYNTAX LldpChassisIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of encoding used to identify the chassis associated
with the remote system."
-- REFERENCE "IEEE 802.1AB-2005 9.5.2.2"
::= { ethIntfEntry 46 }
ethIntfLldpRemChassisId OBJECT-TYPE
SYNTAX LldpChassisId
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value used to identify the chassis component
associated with the remote system."
-- REFERENCE "IEEE 802.1AB-2005 9.5.2.3"
::= { ethIntfEntry 47 }
ethIntfLldpRemPortIdSubtype OBJECT-TYPE
SYNTAX LldpPortIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of port identifier encoding used in the associated
'ethIntfLldpRemPortId' object."
-- REFERENCE "IEEE 802.1AB-2005 9.5.3.2"
::= { ethIntfEntry 48 }
ethIntfLldpRemPortId OBJECT-TYPE
SYNTAX LldpPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value used to identify the port component
associated with the remote system."
-- REFERENCE "IEEE 802.1AB-2005 9.5.3.3"
::= { ethIntfEntry 49 }
ethIntfBouncingStateChangeCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Count of the Ethernet facility operational state changes sinse last reboot"
::= { ethIntfEntry 50 }
ethIntfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
Ethernet table, which in turn controls provisioning and
deprovisioning of Ethernet facilities."
::= { ethIntfEntry 100 }
-----------------------------------------------------------------------
-- Objects related to ODU-N facilities on Muxponder Circuit Packs
-----------------------------------------------------------------------
odunTable OBJECT-TYPE
SYNTAX SEQUENCE OF OdunEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every ODU-N
facility on the system."
::= { facilities 15 }
odunEntry OBJECT-TYPE
SYNTAX OdunEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the ODU-N table."
INDEX { odunTypeIdx,
odunShelfIdx,
odunSlotIdx,
odunPortIdx }
::= { odunTable 1 }
OdunEntry ::= SEQUENCE { odunTypeIdx OdunType,
odunShelfIdx INTEGER,
odunSlotIdx INTEGER,
odunPortIdx INTEGER,
odunIdx INTEGER }
odunTypeIdx OBJECT-TYPE
SYNTAX OdunType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The specific type of ODU-N which is provisioned."
::= { odunEntry 1 }
odunShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the ODU-N facility is
provisioned."
::= { odunEntry 2 }
odunSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within which the ODU-N facility is
provisioned."
::= { odunEntry 3 }
odunPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the ODU-N
facility is provisioned."
::= { odunEntry 4 }
odunIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The ODU-N channel number within the port in which the ODU-N
facility exists."
::= { odunEntry 5 }
-----------------------------------------------------------------------
-- Objects related to provisioned Bit Rate Independent (BRI)
-- facilities on Muxponder Circuit Packs
-----------------------------------------------------------------------
briTable OBJECT-TYPE
SYNTAX SEQUENCE OF BriEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned
Bit Rate Independent (BRI) facility on the system.
Each row contains a list of attributes that pertain
to the facility."
::= { facilities 16 }
briEntry OBJECT-TYPE
SYNTAX BriEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the BRI table."
INDEX { briShelfIdx,
briSlotIdx,
briPortIdx }
::= { briTable 1 }
BriEntry ::= SEQUENCE { briShelfIdx INTEGER,
briSlotIdx INTEGER,
briPortIdx INTEGER,
briProtocol INTEGER,
briOpticalPwrReceivedMinTh FixedX10,
briOpticalPwrReceivedMaxTh FixedX10,
briOpticalPwrTransmittedMinTh FixedX10,
briOpticalPwrTransmittedMaxTh FixedX10,
briOpticalPwrReceived FixedX10,
briOpticalPwrTransmitted FixedX10,
briPEC DisplayString,
briAdminStatus AdminStatus,
briOperStatus OperStatus,
briOperStatQlfr OperStatQlfr,
briAutoEnableTimer HoursAndMinutes,
briActAutoEnableTimer HoursAndMinutes,
briWavelength FixedX100,
briVendorPN1 DisplayString,
briVendorPN2 DisplayString,
briVendorPN3 DisplayString,
briPhyPMMon INTEGER,
briLaserStatus INTEGER,
briId1 DisplayString,
briFiberType FiberType,
briCustom1 DisplayString,
briBitRate FixedX100,
briRemoteId DisplayString,
briRowStatus RowStatus }
briShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the BRI facility is
provisioned."
::= { briEntry 1 }
briSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within which the BRI facility
is provisioned."
::= { briEntry 2 }
briPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
BRI facility is provisioned."
::= { briEntry 3 }
briProtocol OBJECT-TYPE
SYNTAX INTEGER { fx100 (1),
escon (2),
sdSdi (3),
hdSdi (4),
hdSdi1001 (5),
dvbAsi (6)}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The protocol of the BRI signal which is provisioned."
::= { briEntry 4 }
briOpticalPwrReceivedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received minimum threshold."
::= { briEntry 5 }
briOpticalPwrReceivedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power received maximum threshold."
::= { briEntry 6 }
briOpticalPwrTransmittedMinTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted minimum threshold."
::= { briEntry 7 }
briOpticalPwrTransmittedMaxTh OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the optical power transmitted maximum threshold."
::= { briEntry 8 }
briOpticalPwrReceived OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power received on the input of the transceiver."
::= { briEntry 9 }
briOpticalPwrTransmitted OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The optical power transmitted at the output of the
transceiver."
::= { briEntry 10 }
briPEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned Product Equipment Code used to
validate the physically present optical transceiver on the
BRI port."
DEFVAL { "" }
::= { briEntry 11 }
briAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the BRI facility."
DEFVAL { enabled }
::= { briEntry 12 }
briOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the BRI facility."
::= { briEntry 13 }
briOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is a textual list of qualifiers about the reported
operational status of the BRI facility."
::= { briEntry 14 }
briAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the auto-enable timer for the targeted BRI
facility. This value only applies if the briAdminStatus object
is set to autoEnabled. Otherwise, the value returned is
000-00."
DEFVAL { "008-00" }
::= { briEntry 15 }
briActAutoEnableTimer OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time remaining on the auto-enable timer if it is
actively counting down. Otherwise, the value returned is
000-00."
::= { briEntry 16 }
briWavelength OBJECT-TYPE
SYNTAX FixedX100
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The wavelength to be transmitted by the transceiver on the
BRI facility port. This is a mandatory object when a
row of the fiber channel table is created."
::= { briEntry 17 }
briVendorPN1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the BRI facility port."
DEFVAL { "" }
::= { briEntry 18 }
briVendorPN2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the BRI facility port."
DEFVAL { "" }
::= { briEntry 19 }
briVendorPN3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optionally provisioned part number used to validate the
optical transceiver on the BRI facility port."
DEFVAL { "" }
::= { briEntry 20 }
briPhyPMMon OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates if the BRI facility is configured to
report threshold crossing conditions for physical layer
performance monitoring parameters."
DEFVAL { disabled }
::= { briEntry 21 }
briLaserStatus OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of the operational status of the transceiver
laser on the BRI facility port."
::= { briEntry 22 }
briId1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
BRI facility in a manner useful to the user."
DEFVAL { "" }
::= { briEntry 23 }
briFiberType OBJECT-TYPE
SYNTAX FiberType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An optional specification of the fiber type that interfaces to
the BRI facility port."
DEFVAL { none }
::= { briEntry 24 }
briCustom1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A variable length text string for operating company use."
DEFVAL { "" }
::= { briEntry 25 }
briBitRate OBJECT-TYPE
SYNTAX FixedX100
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The bit rate transmitted by the BRI facility port in Mbps."
::= { briEntry 26 }
briRemoteId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Identifies the remote node and port to which the
Bitrate Independent port is connected, in the
format prescribed by the PSM network management
system."
DEFVAL { "" }
::= { briEntry 27 }
briRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
BRI table, which in turn controls provisioning and
deprovisioning of BRI facilities."
::= { briEntry 100 }
-----------------------------------------------------------------------
-- Objects used to retrieve current Optical Amplifier
-- Performance Monitoring statistics
--
-- A listing of current optical amplifier PM values are contained in
-- the oaCrntPMTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each set of current optical amplifier
-- PM data. The following table lists the objects in each entry of the
-- oaCrntPMTable.
-----------------------------------------------------------------------
oaCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the optical amplifier facilities on the NE."
::= { performance 1 }
oaCrntPMEntry OBJECT-TYPE
SYNTAX OaCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the optical amplifier current
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a current
measurement interval for a given optical amplifier."
INDEX { oaCrntPMOaTypeIdx,
oaCrntPMShelfIdx,
oaCrntPMSlotIdx,
oaCrntPMOaIdx,
oaCrntPMIntervalTypeIdx }
::= { oaCrntPMTable 1 }
OaCrntPMEntry ::= SEQUENCE { oaCrntPMOaTypeIdx OaType,
oaCrntPMShelfIdx INTEGER,
oaCrntPMSlotIdx INTEGER,
oaCrntPMOaIdx INTEGER,
oaCrntPMIntervalTypeIdx PMIntervalType,
oaCrntPMCaseTempValue INTEGER,
oaCrntPMCaseTempTimeStamp DateAndTime,
oaCrntPMCaseTempValidity PMValidity,
oaCrntPMLaser1TempValue INTEGER,
oaCrntPMLaser1TempTimeStamp DateAndTime,
oaCrntPMLaser1TempValidity PMValidity,
oaCrntPMLaser2TempValue INTEGER,
oaCrntPMLaser2TempTimeStamp DateAndTime,
oaCrntPMLaser2TempValidity PMValidity,
oaCrntPMOPRValue FixedX10,
oaCrntPMOPRTimeStamp DateAndTime,
oaCrntPMOPRValidity PMValidity,
oaCrntPMSSIOPRValue FixedX10,
oaCrntPMSSIOPRTimeStamp DateAndTime,
oaCrntPMSSIOPRValidity PMValidity,
oaCrntPMOPTValue FixedX10,
oaCrntPMOPTTimeStamp DateAndTime,
oaCrntPMOPTValidity PMValidity,
oaCrntPMMSInsLossValue FixedX10,
oaCrntPMMSInsLossTimeStamp DateAndTime,
oaCrntPMMSInsLossValidity PMValidity,
oaCrntPMEffectiveGainValue FixedX10,
oaCrntPMEffectiveGainTimeStamp DateAndTime,
oaCrntPMEffectiveGainValidity PMValidity,
oaCrntPMFSOOPTValue FixedX10,
oaCrntPMFSOOPTTimeStamp DateAndTime,
oaCrntPMFSOOPTValidity PMValidity,
oaCrntPMLaser1CurrentValue FixedX10,
oaCrntPMLaser1CurrentTimeStamp DateAndTime,
oaCrntPMLaser1CurrentValidity PMValidity,
oaCrntPMLaser2CurrentValue FixedX10,
oaCrntPMLaser2CurrentTimeStamp DateAndTime,
oaCrntPMLaser2CurrentValidity PMValidity,
oaCrntPMLaser1PowerValue FixedX10,
oaCrntPMLaser1PowerTimeStamp DateAndTime,
oaCrntPMLaser1PowerValidity PMValidity,
oaCrntPMLaser2PowerValue FixedX10,
oaCrntPMLaser2PowerTimeStamp DateAndTime,
oaCrntPMLaser2PowerValidity PMValidity,
oaCrntPMOBRValue FixedX10,
oaCrntPMOBRTimeStamp DateAndTime,
oaCrntPMOBRValidity PMValidity,
oaCrntPMVOAValue FixedX10,
oaCrntPMVOATimeStamp DateAndTime,
oaCrntPMVOAValidity PMValidity }
oaCrntPMOaTypeIdx OBJECT-TYPE
SYNTAX OaType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the optical amplifier targeted for PM retrieval."
::= { oaCrntPMEntry 1 }
oaCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the amplifier targeted for
PMs is provisioned."
::= { oaCrntPMEntry 2 }
oaCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the optical amplifier
targeted for PMs is provisioned."
::= { oaCrntPMEntry 3 }
oaCrntPMOaIdx OBJECT-TYPE
SYNTAX INTEGER (1..1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the amplifier port on which the circuit pack for
PMs is targeted."
::= { oaCrntPMEntry 4 }
oaCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { oaCrntPMEntry 5 }
oaCrntPMCaseTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier case temperature."
::= { oaCrntPMEntry 6 }
oaCrntPMCaseTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the case temperature value."
::= { oaCrntPMEntry 7 }
oaCrntPMCaseTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided case temperature
value."
::= { oaCrntPMEntry 8 }
oaCrntPMLaser1TempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 1 temperature."
::= { oaCrntPMEntry 9 }
oaCrntPMLaser1TempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 1 temperature value."
::= { oaCrntPMEntry 10 }
oaCrntPMLaser1TempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 1 temperature
value."
::= { oaCrntPMEntry 11 }
oaCrntPMLaser2TempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 2 temperature."
::= { oaCrntPMEntry 12 }
oaCrntPMLaser2TempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 2 temperature value."
::= { oaCrntPMEntry 13 }
oaCrntPMLaser2TempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 2 temperature
value."
::= { oaCrntPMEntry 14 }
oaCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the amplifer."
::= { oaCrntPMEntry 15 }
oaCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { oaCrntPMEntry 16 }
oaCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { oaCrntPMEntry 17 }
oaCrntPMSSIOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the second stage of
the amplifier."
::= { oaCrntPMEntry 18 }
oaCrntPMSSIOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the second stage input optical
power received value."
::= { oaCrntPMEntry 19 }
oaCrntPMSSIOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided second stage input
optical power received value."
::= { oaCrntPMEntry 20 }
oaCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the amplifier."
::= { oaCrntPMEntry 21 }
oaCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { oaCrntPMEntry 22 }
oaCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { oaCrntPMEntry 23 }
oaCrntPMMSInsLossValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The mid-stage insertion loss."
::= { oaCrntPMEntry 24 }
oaCrntPMMSInsLossTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the mid-stage insertion loss
value."
::= { oaCrntPMEntry 25 }
oaCrntPMMSInsLossValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided mid-stage insertion
loss value."
::= { oaCrntPMEntry 26 }
oaCrntPMEffectiveGainValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The effective gain of the optical amplifier. This reading is
compensated for amplified spontaneous emissions."
::= { oaCrntPMEntry 27 }
oaCrntPMEffectiveGainTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the effective gain value."
::= { oaCrntPMEntry 28 }
oaCrntPMEffectiveGainValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided effective gain value."
::= { oaCrntPMEntry 29 }
oaCrntPMFSOOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the first stage
of the amplifier."
::= { oaCrntPMEntry 30 }
oaCrntPMFSOOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the first stage output optical
power transmitted value."
::= { oaCrntPMEntry 31 }
oaCrntPMFSOOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided first stage output
optical power transmitted value."
::= { oaCrntPMEntry 32 }
oaCrntPMLaser1CurrentValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mAmp/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 1 current."
::= { oaCrntPMEntry 33 }
oaCrntPMLaser1CurrentTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 1 current value."
::= { oaCrntPMEntry 34 }
oaCrntPMLaser1CurrentValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 1 current value."
::= { oaCrntPMEntry 35 }
oaCrntPMLaser2CurrentValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mAmp/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 2 current."
::= { oaCrntPMEntry 36 }
oaCrntPMLaser2CurrentTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 2 current value."
::= { oaCrntPMEntry 37 }
oaCrntPMLaser2CurrentValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 2 current value."
::= { oaCrntPMEntry 38 }
oaCrntPMLaser1PowerValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mWatts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 1 power."
::= { oaCrntPMEntry 39 }
oaCrntPMLaser1PowerTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 1 power value."
::= { oaCrntPMEntry 40 }
oaCrntPMLaser1PowerValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 1 power value."
::= { oaCrntPMEntry 41 }
oaCrntPMLaser2PowerValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mWatts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 2 power."
::= { oaCrntPMEntry 42 }
oaCrntPMLaser2PowerTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 2 power value."
::= { oaCrntPMEntry 43 }
oaCrntPMLaser2PowerValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 2 power value."
::= { oaCrntPMEntry 44 }
oaCrntPMOBRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The back reflected optical power measured at the output of the
second stage of the optical amplifier."
::= { oaCrntPMEntry 45 }
oaCrntPMOBRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical back reflection value."
::= { oaCrntPMEntry 46 }
oaCrntPMOBRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical back reflection
value."
::= { oaCrntPMEntry 47 }
oaCrntPMVOAValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The variable optical attenuation of the amplifier."
::= { oaCrntPMEntry 48 }
oaCrntPMVOATimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the variable optical attenuation
value."
::= { oaCrntPMEntry 49 }
oaCrntPMVOAValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided variable optical
attenuation value."
::= { oaCrntPMEntry 50 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical Optical Amplifier
-- Performance Monitoring statistics
--
-- A listing of historical optical amplifier PM values are contained in
-- the oaHistPMTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each set of historical optical amplifier
-- PM data.
--
-- The following table lists the objects in each entry of the
-- oaHistPMTable.
-----------------------------------------------------------------------
oaHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the optical amplifier facilities on the NE."
::= { performance 2 }
oaHistPMEntry OBJECT-TYPE
SYNTAX OaHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the optical amplifier historical
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a historical
measurement interval for a given optical amplifier."
INDEX { oaHistPMOaTypeIdx,
oaHistPMShelfIdx,
oaHistPMSlotIdx,
oaHistPMOaIdx,
oaHistPMIntervalTypeIdx,
oaHistPMIntervalIdx }
::= { oaHistPMTable 1 }
OaHistPMEntry ::= SEQUENCE { oaHistPMOaTypeIdx OaType,
oaHistPMShelfIdx INTEGER,
oaHistPMSlotIdx INTEGER,
oaHistPMOaIdx INTEGER,
oaHistPMIntervalTypeIdx PMIntervalType,
oaHistPMIntervalIdx INTEGER,
oaHistPMCaseTempValue INTEGER,
oaHistPMCaseTempTimeStamp DateAndTime,
oaHistPMCaseTempValidity PMValidity,
oaHistPMLaser1TempValue INTEGER,
oaHistPMLaser1TempTimeStamp DateAndTime,
oaHistPMLaser1TempValidity PMValidity,
oaHistPMLaser2TempValue INTEGER,
oaHistPMLaser2TempTimeStamp DateAndTime,
oaHistPMLaser2TempValidity PMValidity,
oaHistPMOPRValue FixedX10,
oaHistPMOPRTimeStamp DateAndTime,
oaHistPMOPRValidity PMValidity,
oaHistPMSSIOPRValue FixedX10,
oaHistPMSSIOPRTimeStamp DateAndTime,
oaHistPMSSIOPRValidity PMValidity,
oaHistPMOPTValue FixedX10,
oaHistPMOPTTimeStamp DateAndTime,
oaHistPMOPTValidity PMValidity,
oaHistPMMSInsLossValue FixedX10,
oaHistPMMSInsLossTimeStamp DateAndTime,
oaHistPMMSInsLossValidity PMValidity,
oaHistPMEffectiveGainValue FixedX10,
oaHistPMEffectiveGainTimeStamp DateAndTime,
oaHistPMEffectiveGainValidity PMValidity,
oaHistPMFSOOPTValue FixedX10,
oaHistPMFSOOPTTimeStamp DateAndTime,
oaHistPMFSOOPTValidity PMValidity,
oaHistPMLaser1CurrentValue FixedX10,
oaHistPMLaser1CurrentTimeStamp DateAndTime,
oaHistPMLaser1CurrentValidity PMValidity,
oaHistPMLaser2CurrentValue FixedX10,
oaHistPMLaser2CurrentTimeStamp DateAndTime,
oaHistPMLaser2CurrentValidity PMValidity,
oaHistPMLaser1PowerValue FixedX10,
oaHistPMLaser1PowerTimeStamp DateAndTime,
oaHistPMLaser1PowerValidity PMValidity,
oaHistPMLaser2PowerValue FixedX10,
oaHistPMLaser2PowerTimeStamp DateAndTime,
oaHistPMLaser2PowerValidity PMValidity,
oaHistPMOBRValue FixedX10,
oaHistPMOBRTimeStamp DateAndTime,
oaHistPMOBRValidity PMValidity,
oaHistPMVOAValue FixedX10,
oaHistPMVOATimeStamp DateAndTime,
oaHistPMVOAValidity PMValidity }
oaHistPMOaTypeIdx OBJECT-TYPE
SYNTAX OaType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the optical amplifier targeted for PM retrieval."
::= { oaHistPMEntry 1 }
oaHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the amplifier targeted for
PMs is provisioned."
::= { oaHistPMEntry 2 }
oaHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the optical amplifier
targeted for PMs is provisioned."
::= { oaHistPMEntry 3 }
oaHistPMOaIdx OBJECT-TYPE
SYNTAX INTEGER (1..1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the amplifier port on the circuit pack targeted
for PMs."
::= { oaHistPMEntry 4 }
oaHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { oaHistPMEntry 5 }
oaHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1..96 for 15-minute
bins, and for 1-day historical bins, the value is 1."
::= { oaHistPMEntry 6 }
oaHistPMCaseTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier case temperature."
::= { oaHistPMEntry 7 }
oaHistPMCaseTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the case temperature value."
::= { oaHistPMEntry 8 }
oaHistPMCaseTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided case temperature
value."
::= { oaHistPMEntry 9 }
oaHistPMLaser1TempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 1 temperature."
::= { oaHistPMEntry 10 }
oaHistPMLaser1TempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 1 temperature value."
::= { oaHistPMEntry 11 }
oaHistPMLaser1TempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 1 temperature
value."
::= { oaHistPMEntry 12 }
oaHistPMLaser2TempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 2 temperature."
::= { oaHistPMEntry 13 }
oaHistPMLaser2TempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 2 temperature value."
::= { oaHistPMEntry 14 }
oaHistPMLaser2TempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 2 temperature
value."
::= { oaHistPMEntry 15 }
oaHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the amplifer."
::= { oaHistPMEntry 16 }
oaHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { oaHistPMEntry 17 }
oaHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { oaHistPMEntry 18 }
oaHistPMSSIOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the second stage of
the amplifier."
::= { oaHistPMEntry 19 }
oaHistPMSSIOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the second stage input optical
power received value."
::= { oaHistPMEntry 20 }
oaHistPMSSIOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided second stage input
optical power received value."
::= { oaHistPMEntry 21 }
oaHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the amplifier."
::= { oaHistPMEntry 22 }
oaHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { oaHistPMEntry 23 }
oaHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { oaHistPMEntry 24 }
oaHistPMMSInsLossValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The mid-stage insertion loss."
::= { oaHistPMEntry 25 }
oaHistPMMSInsLossTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the mid-stage insertion loss
value."
::= { oaHistPMEntry 26 }
oaHistPMMSInsLossValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided mid-stage insertion
loss value."
::= { oaHistPMEntry 27 }
oaHistPMEffectiveGainValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The effective gain of the optical amplifier. This reading is
compensated for amplified spontaneous emissions."
::= { oaHistPMEntry 28 }
oaHistPMEffectiveGainTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the effective gain value."
::= { oaHistPMEntry 29 }
oaHistPMEffectiveGainValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided effective gain value."
::= { oaHistPMEntry 30 }
oaHistPMFSOOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the first stage
of the amplifier."
::= { oaHistPMEntry 31 }
oaHistPMFSOOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the first stage output optical
power transmitted value."
::= { oaHistPMEntry 32 }
oaHistPMFSOOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided first stage output
optical power transmitted value."
::= { oaHistPMEntry 33 }
oaHistPMLaser1CurrentValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mAmp/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 1 current."
::= { oaHistPMEntry 34 }
oaHistPMLaser1CurrentTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 1 current value."
::= { oaHistPMEntry 35 }
oaHistPMLaser1CurrentValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 1 current value."
::= { oaHistPMEntry 36 }
oaHistPMLaser2CurrentValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mAmp/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 2 current."
::= { oaHistPMEntry 37 }
oaHistPMLaser2CurrentTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 2 current value."
::= { oaHistPMEntry 38 }
oaHistPMLaser2CurrentValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 2 current value."
::= { oaHistPMEntry 39 }
oaHistPMLaser1PowerValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mWatts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 1 power."
::= { oaHistPMEntry 40 }
oaHistPMLaser1PowerTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 1 power value."
::= { oaHistPMEntry 41 }
oaHistPMLaser1PowerValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 1 power value."
::= { oaHistPMEntry 42 }
oaHistPMLaser2PowerValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mWatts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical amplifier laser 2 power."
::= { oaHistPMEntry 43 }
oaHistPMLaser2PowerTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser 2 power value."
::= { oaHistPMEntry 44 }
oaHistPMLaser2PowerValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser 2 power value."
::= { oaHistPMEntry 45 }
oaHistPMOBRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The back reflected optical power measured at the output of the
second stage of the optical amplifier."
::= { oaHistPMEntry 46 }
oaHistPMOBRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical back reflection value."
::= { oaHistPMEntry 47 }
oaHistPMOBRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical back reflection
value."
::= { oaHistPMEntry 48 }
oaHistPMVOAValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The variable optical attenuation of the amplifier."
::= { oaHistPMEntry 49 }
oaHistPMVOATimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the variable optical attenuation
value."
::= { oaHistPMEntry 50 }
oaHistPMVOAValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided variable optical
attenuation value."
::= { oaHistPMEntry 51 }
-----------------------------------------------------------------------
-- Objects used to retrieve current Optical Transceiver
-- Performance Monitoring statistics
--
-- A listing of current transceiver PM values are contained in the
-- xcvrCrntPMTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for eachset of current transceiver PM data.
--
-- The following table lists the objects in each entry of the
-- xcvrCrntPMTable.
-----------------------------------------------------------------------
xcvrCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF XcvrCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the optical transceiver facilities on the NE."
::= { performance 3 }
xcvrCrntPMEntry OBJECT-TYPE
SYNTAX XcvrCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the optical transceiver current
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a current
measurement interval for a given optical transceiver."
INDEX { xcvrCrntPMTypeIdx,
xcvrCrntPMShelfIdx,
xcvrCrntPMSlotIdx,
xcvrCrntPMIdx,
xcvrCrntPMIntervalTypeIdx }
::= { xcvrCrntPMTable 1 }
XcvrCrntPMEntry ::= SEQUENCE { xcvrCrntPMTypeIdx XcvrType,
xcvrCrntPMShelfIdx INTEGER,
xcvrCrntPMSlotIdx INTEGER,
xcvrCrntPMIdx INTEGER,
xcvrCrntPMIntervalTypeIdx PMIntervalType,
xcvrCrntPMOPRValue FixedX10,
xcvrCrntPMOPRTimeStamp DateAndTime,
xcvrCrntPMOPRValidity PMValidity,
xcvrCrntPMOPTValue FixedX10,
xcvrCrntPMOPTTimeStamp DateAndTime,
xcvrCrntPMOPTValidity PMValidity,
xcvrCrntPMTempValue INTEGER,
xcvrCrntPMTempTimeStamp DateAndTime,
xcvrCrntPMTempValidity PMValidity,
xcvrCrntPMSupplyVoltageValue FixedX10,
xcvrCrntPMSupplyVoltageTimeStamp DateAndTime,
xcvrCrntPMSupplyVoltageValidity PMValidity,
xcvrCrntPMLBCValue INTEGER,
xcvrCrntPMLBCTimeStamp DateAndTime,
xcvrCrntPMLBCValidity PMValidity,
xcvrCrntPMCVSValue Unsigned32,
xcvrCrntPMCVSTimeStamp DateAndTime,
xcvrCrntPMCVSValidity PMValidity,
xcvrCrntPMESSValue Unsigned32,
xcvrCrntPMESSTimeStamp DateAndTime,
xcvrCrntPMESSValidity PMValidity,
xcvrCrntPMSESSValue Unsigned32,
xcvrCrntPMSESSTimeStamp DateAndTime,
xcvrCrntPMSESSValidity PMValidity,
xcvrCrntPMSEFSSValue Unsigned32,
xcvrCrntPMSEFSSTimeStamp DateAndTime,
xcvrCrntPMSEFSSValidity PMValidity,
xcvrCrntPMRSEBValue Unsigned32,
xcvrCrntPMRSEBTimeStamp DateAndTime,
xcvrCrntPMRSEBValidity PMValidity,
xcvrCrntPMRSBBEValue Unsigned32,
xcvrCrntPMRSBBETimeStamp DateAndTime,
xcvrCrntPMRSBBEValidity PMValidity,
xcvrCrntPMRSESValue Unsigned32,
xcvrCrntPMRSESTimeStamp DateAndTime,
xcvrCrntPMRSESValidity PMValidity,
xcvrCrntPMRSSESValue Unsigned32,
xcvrCrntPMRSSESTimeStamp DateAndTime,
xcvrCrntPMRSSESValidity PMValidity,
xcvrCrntPMRSOFSValue Unsigned32,
xcvrCrntPMRSOFSTimeStamp DateAndTime,
xcvrCrntPMRSOFSValidity PMValidity,
xcvrCrntPMCVValue Unsigned32,
xcvrCrntPMCVTimeStamp DateAndTime,
xcvrCrntPMCVValidity PMValidity,
xcvrCrntPMESValue Unsigned32,
xcvrCrntPMESTimeStamp DateAndTime,
xcvrCrntPMESValidity PMValidity,
xcvrCrntPMSESValue Unsigned32,
xcvrCrntPMSESTimeStamp DateAndTime,
xcvrCrntPMSESValidity PMValidity,
xcvrCrntPMINVBLKValue Unsigned32,
xcvrCrntPMINVBLKTimeStamp DateAndTime,
xcvrCrntPMINVBLKValidity PMValidity,
xcvrCrntPMNBITCRValue Unsigned32,
xcvrCrntPMNBITCRTimeStamp DateAndTime,
xcvrCrntPMNBITCRValidity PMValidity,
xcvrCrntPMNBYTCRValue Unsigned32,
xcvrCrntPMNBYTCRTimeStamp DateAndTime,
xcvrCrntPMNBYTCRValidity PMValidity,
xcvrCrntPMUNCRCDWValue Unsigned32,
xcvrCrntPMUNCRCDWTimeStamp DateAndTime,
xcvrCrntPMUNCRCDWValidity PMValidity,
xcvrCrntPMTBYCRXValue Unsigned64,
xcvrCrntPMTBYCRXTimeStamp DateAndTime,
xcvrCrntPMTBYCRXValidity PMValidity,
xcvrCrntPMTBYCRXInitialize InitializeCmd,
xcvrCrntPMTFRCRXValue Unsigned64,
xcvrCrntPMTFRCRXTimeStamp DateAndTime,
xcvrCrntPMTFRCRXValidity PMValidity,
xcvrCrntPMTFRCRXInitialize InitializeCmd,
xcvrCrntPMBCSTValue Unsigned64,
xcvrCrntPMBCSTTimeStamp DateAndTime,
xcvrCrntPMBCSTValidity PMValidity,
xcvrCrntPMBCSTInitialize InitializeCmd,
xcvrCrntPMMCSTValue Unsigned64,
xcvrCrntPMMCSTTimeStamp DateAndTime,
xcvrCrntPMMCSTValidity PMValidity,
xcvrCrntPMMCSTInitialize InitializeCmd,
xcvrCrntPMSIZE64Value Unsigned64,
xcvrCrntPMSIZE64TimeStamp DateAndTime,
xcvrCrntPMSIZE64Validity PMValidity,
xcvrCrntPMSIZE64Initialize InitializeCmd,
xcvrCrntPMSIZE65To127Value Unsigned64,
xcvrCrntPMSIZE65To127TimeStamp DateAndTime,
xcvrCrntPMSIZE65To127Validity PMValidity,
xcvrCrntPMSIZE65To127Initialize InitializeCmd,
xcvrCrntPMSIZE128To255Value Unsigned64,
xcvrCrntPMSIZE128To255TimeStamp DateAndTime,
xcvrCrntPMSIZE128To255Validity PMValidity,
xcvrCrntPMSIZE128To255Initialize InitializeCmd,
xcvrCrntPMSIZE256To511Value Unsigned64,
xcvrCrntPMSIZE256To511TimeStamp DateAndTime,
xcvrCrntPMSIZE256To511Validity PMValidity,
xcvrCrntPMSIZE256To511Initialize InitializeCmd,
xcvrCrntPMSIZE512To1023Value Unsigned64,
xcvrCrntPMSIZE512To1023TimeStamp DateAndTime,
xcvrCrntPMSIZE512To1023Validity PMValidity,
xcvrCrntPMSIZE512To1023Initialize InitializeCmd,
xcvrCrntPMSIZE1024To1518Value Unsigned64,
xcvrCrntPMSIZE1024To1518TimeStamp DateAndTime,
xcvrCrntPMSIZE1024To1518Validity PMValidity,
xcvrCrntPMSIZE1024To1518Initialize InitializeCmd,
xcvrCrntPMSIZEOver1518Value Unsigned64,
xcvrCrntPMSIZEOver1518TimeStamp DateAndTime,
xcvrCrntPMSIZEOver1518Validity PMValidity,
xcvrCrntPMSIZEOver1518Initialize InitializeCmd,
xcvrCrntPMFCSEValue Unsigned32,
xcvrCrntPMFCSETimeStamp DateAndTime,
xcvrCrntPMFCSEValidity PMValidity,
xcvrCrntPMFRDRValue Unsigned32,
xcvrCrntPMFRDRTimeStamp DateAndTime,
xcvrCrntPMFRDRValidity PMValidity,
xcvrCrntPMUSIZEValue Unsigned32,
xcvrCrntPMUSIZETimeStamp DateAndTime,
xcvrCrntPMUSIZEValidity PMValidity,
xcvrCrntPMOSIZEValue Unsigned32,
xcvrCrntPMOSIZETimeStamp DateAndTime,
xcvrCrntPMOSIZEValidity PMValidity,
xcvrCrntPMFRGTValue Unsigned32,
xcvrCrntPMFRGTTimeStamp DateAndTime,
xcvrCrntPMFRGTValidity PMValidity,
xcvrCrntPMJABRValue Unsigned32,
xcvrCrntPMJABRTimeStamp DateAndTime,
xcvrCrntPMJABRValidity PMValidity,
xcvrCrntPMOTUEBValue Unsigned32,
xcvrCrntPMOTUEBTimeStamp DateAndTime,
xcvrCrntPMOTUEBValidity PMValidity,
xcvrCrntPMOTUBBEValue Unsigned32,
xcvrCrntPMOTUBBETimeStamp DateAndTime,
xcvrCrntPMOTUBBEValidity PMValidity,
xcvrCrntPMOTUESValue Unsigned32,
xcvrCrntPMOTUESTimeStamp DateAndTime,
xcvrCrntPMOTUESValidity PMValidity,
xcvrCrntPMOTUSESValue Unsigned32,
xcvrCrntPMOTUSESTimeStamp DateAndTime,
xcvrCrntPMOTUSESValidity PMValidity,
xcvrCrntPMOTUOFSValue Unsigned32,
xcvrCrntPMOTUOFSTimeStamp DateAndTime,
xcvrCrntPMOTUOFSValidity PMValidity,
xcvrCrntPMSupplyVoltage2Value FixedX10,
xcvrCrntPMSupplyVoltage2TimeStamp DateAndTime,
xcvrCrntPMSupplyVoltage2Validity PMValidity,
xcvrCrntPMCVSInitialize InitializeCmd,
xcvrCrntPMESSInitialize InitializeCmd,
xcvrCrntPMSESSInitialize InitializeCmd,
xcvrCrntPMSEFSSInitialize InitializeCmd,
xcvrCrntPMRSEBInitialize InitializeCmd,
xcvrCrntPMRSBBEInitialize InitializeCmd,
xcvrCrntPMRSESInitialize InitializeCmd,
xcvrCrntPMRSSESInitialize InitializeCmd,
xcvrCrntPMRSOFSInitialize InitializeCmd,
xcvrCrntPMCVInitialize InitializeCmd,
xcvrCrntPMESInitialize InitializeCmd,
xcvrCrntPMSESInitialize InitializeCmd,
xcvrCrntPMINVBLKInitialize InitializeCmd,
xcvrCrntPMNBITCRInitialize InitializeCmd,
xcvrCrntPMNBYTCRInitialize InitializeCmd,
xcvrCrntPMUNCRCDWInitialize InitializeCmd,
xcvrCrntPMFCSEInitialize InitializeCmd,
xcvrCrntPMFRDRInitialize InitializeCmd,
xcvrCrntPMUSIZEInitialize InitializeCmd,
xcvrCrntPMOSIZEInitialize InitializeCmd,
xcvrCrntPMFRGTInitialize InitializeCmd,
xcvrCrntPMJABRInitialize InitializeCmd,
xcvrCrntPMOTUEBInitialize InitializeCmd,
xcvrCrntPMOTUBBEInitialize InitializeCmd,
xcvrCrntPMOTUESInitialize InitializeCmd,
xcvrCrntPMOTUSESInitialize InitializeCmd,
xcvrCrntPMOTUOFSInitialize InitializeCmd,
xcvrCrntPMUASSValue Unsigned32,
xcvrCrntPMUASSTimeStamp DateAndTime,
xcvrCrntPMUASSValidity PMValidity,
xcvrCrntPMUASSInitialize InitializeCmd,
xcvrCrntPMRSUASValue Unsigned32,
xcvrCrntPMRSUASTimeStamp DateAndTime,
xcvrCrntPMRSUASValidity PMValidity,
xcvrCrntPMRSUASInitialize InitializeCmd,
xcvrCrntPMUASValue Unsigned32,
xcvrCrntPMUASTimeStamp DateAndTime,
xcvrCrntPMUASValidity PMValidity,
xcvrCrntPMUASInitialize InitializeCmd,
xcvrCrntPMOTUUASValue Unsigned32,
xcvrCrntPMOTUUASTimeStamp DateAndTime,
xcvrCrntPMOTUUASValidity PMValidity,
xcvrCrntPMOTUUASInitialize InitializeCmd,
xcvrCrntPMOTNBERValue DisplayString,
xcvrCrntPMOTNBERTimeStamp DateAndTime,
xcvrCrntPMOTNBERValidity PMValidity,
xcvrCrntPMOTNBERInitialize InitializeCmd,
xcvrCrntPMOTNAVGBERValue DisplayString,
xcvrCrntPMOTNAVGBERTimeStamp DateAndTime,
xcvrCrntPMOTNAVGBERValidity PMValidity,
xcvrCrntPMOTNAVGBERInitialize InitializeCmd,
xcvrCrntPMNBITCR64BitValue Unsigned64,
xcvrCrntPMNBITCR64BitTimeStamp DateAndTime,
xcvrCrntPMNBITCR64BitValidity PMValidity,
xcvrCrntPMNBITCR64BitInitialize InitializeCmd,
xcvrCrntPMNBYTCR64BitValue Unsigned64,
xcvrCrntPMNBYTCR64BitTimeStamp DateAndTime,
xcvrCrntPMNBYTCR64BitValidity PMValidity,
xcvrCrntPMNBYTCR64BitInitialize InitializeCmd,
xcvrCrntPMOPRMinValue FixedX10,
xcvrCrntPMOPRMinTimeStamp DateAndTime,
xcvrCrntPMOPRMinValidity PMValidity,
xcvrCrntPMOPRMinInitialize InitializeCmd,
xcvrCrntPMOPRMaxValue FixedX10,
xcvrCrntPMOPRMaxTimeStamp DateAndTime,
xcvrCrntPMOPRMaxValidity PMValidity,
xcvrCrntPMOPRMaxInitialize InitializeCmd,
xcvrCrntPMOPRAvgValue FixedX10,
xcvrCrntPMOPRAvgTimeStamp DateAndTime,
xcvrCrntPMOPRAvgValidity PMValidity,
xcvrCrntPMOPRAvgInitialize InitializeCmd,
xcvrCrntPMOPTMinValue FixedX10,
xcvrCrntPMOPTMinTimeStamp DateAndTime,
xcvrCrntPMOPTMinValidity PMValidity,
xcvrCrntPMOPTMinInitialize InitializeCmd,
xcvrCrntPMOPTMaxValue FixedX10,
xcvrCrntPMOPTMaxTimeStamp DateAndTime,
xcvrCrntPMOPTMaxValidity PMValidity,
xcvrCrntPMOPTMaxInitialize InitializeCmd,
xcvrCrntPMOPTAvgValue FixedX10,
xcvrCrntPMOPTAvgTimeStamp DateAndTime,
xcvrCrntPMOPTAvgValidity PMValidity,
xcvrCrntPMOPTAvgInitialize InitializeCmd }
xcvrCrntPMTypeIdx OBJECT-TYPE
SYNTAX XcvrType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the optical transceiver targeted for PMs."
::= { xcvrCrntPMEntry 1 }
xcvrCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The shelf number on which the optical transceiver targeted for
PMs is provisioned."
::= { xcvrCrntPMEntry 2 }
xcvrCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The slot number on which the optical transceiver targeted for
PMs is provisioned."
::= { xcvrCrntPMEntry 3 }
xcvrCrntPMIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The optical transceiver port number on the circuit pack that
is targeted for PMs."
::= { xcvrCrntPMEntry 4 }
xcvrCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { xcvrCrntPMEntry 5 }
xcvrCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the transceiver."
::= { xcvrCrntPMEntry 6 }
xcvrCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { xcvrCrntPMEntry 7 }
xcvrCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { xcvrCrntPMEntry 8 }
xcvrCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the
transceiver."
::= { xcvrCrntPMEntry 9 }
xcvrCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { xcvrCrntPMEntry 10 }
xcvrCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { xcvrCrntPMEntry 11 }
xcvrCrntPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical transceiver temperature."
::= { xcvrCrntPMEntry 12 }
xcvrCrntPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { xcvrCrntPMEntry 13 }
xcvrCrntPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { xcvrCrntPMEntry 14 }
xcvrCrntPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The transceiver supply voltage."
::= { xcvrCrntPMEntry 15 }
xcvrCrntPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { xcvrCrntPMEntry 16 }
xcvrCrntPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { xcvrCrntPMEntry 17 }
xcvrCrntPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The transceiver laser bias current."
::= { xcvrCrntPMEntry 18 }
xcvrCrntPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { xcvrCrntPMEntry 19 }
xcvrCrntPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { xcvrCrntPMEntry 20 }
xcvrCrntPMCVSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations at the section layer. This
object applies only to transciever ports provisioned for a
SONET OC-N protocol."
::= { xcvrCrntPMEntry 21 }
xcvrCrntPMCVSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer coding violations
value."
::= { xcvrCrntPMEntry 22 }
xcvrCrntPMCVSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer coding
violations value."
::= { xcvrCrntPMEntry 23 }
xcvrCrntPMESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the section layer. This object
applies only to transciever ports provisioned for a SONET OC-N
protocol."
::= { xcvrCrntPMEntry 24 }
xcvrCrntPMESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer errored seconds
value."
::= { xcvrCrntPMEntry 25 }
xcvrCrntPMESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer errored
seconds value."
::= { xcvrCrntPMEntry 26 }
xcvrCrntPMSESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the section layer.
This object applies only to transciever ports provisioned for
a SONET OC-N protocol."
::= { xcvrCrntPMEntry 27 }
xcvrCrntPMSESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
seconds value."
::= { xcvrCrntPMEntry 28 }
xcvrCrntPMSESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored seconds value."
::= { xcvrCrntPMEntry 29 }
xcvrCrntPMSEFSSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored framing seconds at the section
layer. This object applies only to transciever ports
provisioned for a SONET OC-N protocol."
::= { xcvrCrntPMEntry 30 }
xcvrCrntPMSEFSSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
framing seconds value."
::= { xcvrCrntPMEntry 31 }
xcvrCrntPMSEFSSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored framing seconds value."
::= { xcvrCrntPMEntry 32 }
xcvrCrntPMRSEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section errored blocks. This object
applies only to transciever ports provisioned for a SDH STM-N
protocol."
::= { xcvrCrntPMEntry 33 }
xcvrCrntPMRSEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section errored
blocks value."
::= { xcvrCrntPMEntry 34 }
xcvrCrntPMRSEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
errored blocks value."
::= { xcvrCrntPMEntry 35 }
xcvrCrntPMRSBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section background block errors. This
object applies only to transciever ports provisioned for a SDH
STM-N protocol."
::= { xcvrCrntPMEntry 36 }
xcvrCrntPMRSBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section background
block errors value."
::= { xcvrCrntPMEntry 37 }
xcvrCrntPMRSBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
background block errors value."
::= { xcvrCrntPMEntry 38 }
xcvrCrntPMRSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section errored seconds. This object
applies only to transciever ports provisioned for a SDH STM-N
protocol."
::= { xcvrCrntPMEntry 39 }
xcvrCrntPMRSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section errored
seconds value."
::= { xcvrCrntPMEntry 40 }
xcvrCrntPMRSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
errored seconds value."
::= { xcvrCrntPMEntry 41 }
xcvrCrntPMRSSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section severely errored seconds.
This object applies only to transciever ports provisioned for
a SDH STM-N protocol."
::= { xcvrCrntPMEntry 42 }
xcvrCrntPMRSSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section severely
errored seconds value."
::= { xcvrCrntPMEntry 43 }
xcvrCrntPMRSSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
severely errored seconds value."
::= { xcvrCrntPMEntry 44 }
xcvrCrntPMRSOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section out-of-frame seconds. This
object applies only to transciever ports provisioned for a SDH
STM-N protocol."
::= { xcvrCrntPMEntry 45 }
xcvrCrntPMRSOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section
out-of-frame seconds value."
::= { xcvrCrntPMEntry 46 }
xcvrCrntPMRSOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
out-of-frame seconds value."
::= { xcvrCrntPMEntry 47 }
xcvrCrntPMCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations. This object applies only to
transciever ports provisioned for the gigabit ethernet
protocol or a fiber channel protocol."
::= { xcvrCrntPMEntry 48 }
xcvrCrntPMCVTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the coding violations value."
::= { xcvrCrntPMEntry 49 }
xcvrCrntPMCVValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided coding violations
value."
::= { xcvrCrntPMEntry 50 }
xcvrCrntPMESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds. This object applies only to
transciever ports provisioned for an ethernet protocol
or a fiber channel protocol."
::= { xcvrCrntPMEntry 51 }
xcvrCrntPMESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the errored seconds value."
::= { xcvrCrntPMEntry 52 }
xcvrCrntPMESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided errored seconds value."
::= { xcvrCrntPMEntry 53 }
xcvrCrntPMSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds. This object applies
only to transciever ports provisioned for an ethernet
protocol or a fiber channel protocol."
::= { xcvrCrntPMEntry 54 }
xcvrCrntPMSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the severely errored seconds
value."
::= { xcvrCrntPMEntry 55 }
xcvrCrntPMSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided severely errored
seconds value."
::= { xcvrCrntPMEntry 56 }
xcvrCrntPMINVBLKValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of invalid blocks. This object applies only to
transciever ports provisioned for the 10 gigabit ethernet LAN
protocol."
::= { xcvrCrntPMEntry 57 }
xcvrCrntPMINVBLKTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the invalid blocks value."
::= { xcvrCrntPMEntry 58 }
xcvrCrntPMINVBLKValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided invalid blocks value."
::= { xcvrCrntPMEntry 59 }
xcvrCrntPMNBITCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bits corrected. This object
applies only to transciever ports provisioned for a protocol
that includes Forward Error Correction (FEC)."
::= { xcvrCrntPMEntry 60 }
xcvrCrntPMNBITCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bits corrected
value."
::= { xcvrCrntPMEntry 61 }
xcvrCrntPMNBITCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bits
corrected value."
::= { xcvrCrntPMEntry 62 }
xcvrCrntPMNBYTCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bytes corrected. This object
applies only to transciever ports provisioned for a protocol
that includes Forward Error Correction (FEC)."
::= { xcvrCrntPMEntry 63 }
xcvrCrntPMNBYTCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bytes corrected
value."
::= { xcvrCrntPMEntry 64 }
xcvrCrntPMNBYTCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bytes
corrected value."
::= { xcvrCrntPMEntry 65 }
xcvrCrntPMUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of uncorrectable codewords. This object
applies only to transciever ports provisioned for a protocol
that includes Forward Error Correction (FEC)."
::= { xcvrCrntPMEntry 66 }
xcvrCrntPMUNCRCDWTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the uncorrectable codewords value."
::= { xcvrCrntPMEntry 67 }
xcvrCrntPMUNCRCDWValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided uncorrectable codewords
value."
::= { xcvrCrntPMEntry 68 }
xcvrCrntPMTBYCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of bytes of data (including those in bad
frames) received (excluding framing bits but including FCS
octets). This object applies only to transceiver ports
provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 69 }
xcvrCrntPMTBYCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the received bytes count value."
::= { xcvrCrntPMEntry 70 }
xcvrCrntPMTBYCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided received bytes count
value."
::= { xcvrCrntPMEntry 71 }
xcvrCrntPMTBYCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMTBYCRXValue
object to 0."
::= { xcvrCrntPMEntry 72 }
xcvrCrntPMTFRCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of received frames (incl. bad frames,
broadcast frames, and multicast frames received). This object
applies only to transceiver ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 73 }
xcvrCrntPMTFRCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total received frames count
value."
::= { xcvrCrntPMEntry 74 }
xcvrCrntPMTFRCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided received frames count
value."
::= { xcvrCrntPMEntry 75 }
xcvrCrntPMTFRCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMTFRCRXValue
object to 0."
::= { xcvrCrntPMEntry 76 }
xcvrCrntPMBCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
the broadcast address. Note that this does not include
multicast frames. This object applies only to transceiver
ports provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 77 }
xcvrCrntPMBCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the broadcast packets received
count value."
::= { xcvrCrntPMEntry 78 }
xcvrCrntPMBCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided broadcast packets
received count value."
::= { xcvrCrntPMEntry 79 }
xcvrCrntPMBCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMBCSTValue object
to 0."
::= { xcvrCrntPMEntry 80 }
xcvrCrntPMMCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
a multicast address. Note that this number does not include
frames directed to the broadcast address. This object applies
only to transceiver ports provisioned for the 10 gigabit
ethernet LAN protocol."
::= { xcvrCrntPMEntry 81 }
xcvrCrntPMMCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multicast packets received
count value."
::= { xcvrCrntPMEntry 82 }
xcvrCrntPMMCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multicast packets
received count value."
::= { xcvrCrntPMEntry 83 }
xcvrCrntPMMCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMMCSTValue object
to 0."
::= { xcvrCrntPMEntry 84 }
xcvrCrntPMSIZE64Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of 64 byte frames received (excluding framing
bits but including FCS octets). This object applies only to
transceiver ports provisioned for the 10 gigabit ethernet LAN
protocol."
::= { xcvrCrntPMEntry 85 }
xcvrCrntPMSIZE64TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of 64-byte packets
received."
::= { xcvrCrntPMEntry 86 }
xcvrCrntPMSIZE64Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of 64-byte
packets packets received."
::= { xcvrCrntPMEntry 87 }
xcvrCrntPMSIZE64Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMSIZE64Value
object to 0."
::= { xcvrCrntPMEntry 88 }
xcvrCrntPMSIZE65To127Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 65 to 127 bytes
inclusive in length (excluding framing bits but including FCS
octets). This object applies only to transceiver ports
provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 89 }
xcvrCrntPMSIZE65To127TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 65 and
127 bytes."
::= { xcvrCrntPMEntry 90 }
xcvrCrntPMSIZE65To127Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 65 and 127 bytes."
::= { xcvrCrntPMEntry 91 }
xcvrCrntPMSIZE65To127Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMSIZE65To127Value
object to 0."
::= { xcvrCrntPMEntry 92 }
xcvrCrntPMSIZE128To255Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 128 to 255 bytes
inclusive in length (excluding framing bits but including FCS
octets). This object applies only to transceiver ports
provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 93 }
xcvrCrntPMSIZE128To255TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 128
and 255 bytes."
::= { xcvrCrntPMEntry 94 }
xcvrCrntPMSIZE128To255Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 128 and 255 bytes."
::= { xcvrCrntPMEntry 95 }
xcvrCrntPMSIZE128To255Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
xcvrCrntPMSIZE128To255Value object to 0."
::= { xcvrCrntPMEntry 96 }
xcvrCrntPMSIZE256To511Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 256 to 511 bytes
inclusive in length (excluding framing bits but including FCS
octets). This object applies only to transceiver ports
provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 97 }
xcvrCrntPMSIZE256To511TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 256
and 511 bytes."
::= { xcvrCrntPMEntry 98 }
xcvrCrntPMSIZE256To511Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 256 and 511 bytes."
::= { xcvrCrntPMEntry 99 }
xcvrCrntPMSIZE256To511Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
xcvrCrntPMSIZE256To511Value object to 0."
::= { xcvrCrntPMEntry 100 }
xcvrCrntPMSIZE512To1023Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 512 to 1023 bytes
inclusive in length (excluding framing bits but including FCS
octets). This object applies only to transceiver ports
provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 101 }
xcvrCrntPMSIZE512To1023TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 512
and 1023 bytes."
::= { xcvrCrntPMEntry 102 }
xcvrCrntPMSIZE512To1023Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 512 and 1023 bytes."
::= { xcvrCrntPMEntry 103 }
xcvrCrntPMSIZE512To1023Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
xcvrCrntPMSIZE512To1023Value object to 0."
::= { xcvrCrntPMEntry 104 }
xcvrCrntPMSIZE1024To1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 1024 to 1518
bytes inclusive in length (excluding framing bits but
including FCS octets). This object applies only to transceiver
ports provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 105 }
xcvrCrntPMSIZE1024To1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 1024
and 1518 bytes."
::= { xcvrCrntPMEntry 106 }
xcvrCrntPMSIZE1024To1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 1024 and 1518 bytes."
::= { xcvrCrntPMEntry 107 }
xcvrCrntPMSIZE1024To1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
xcvrCrntPMSIZE1024To1518Value object to 0."
::= { xcvrCrntPMEntry 108 }
xcvrCrntPMSIZEOver1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are greater than or
equal to 1519 bytes in length (excluding framing bits but
including FCS octets). This object applies only to transceiver
ports provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 109 }
xcvrCrntPMSIZEOver1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets over 1518
bytes."
::= { xcvrCrntPMEntry 110 }
xcvrCrntPMSIZEOver1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets over
1518 bytes."
::= { xcvrCrntPMEntry 111 }
xcvrCrntPMSIZEOver1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
xcvrCrntPMSIZEOver1518Value object to 0."
::= { xcvrCrntPMEntry 112 }
xcvrCrntPMFCSEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of packets that had a valid length but had either a
Frame Check Sequence (FCS) or a bad FCS with a non-integral
number of octets (Alignment Error) . This object applies only
to transceiver ports provisioned for the 10 gigabit ethernet
LAN protocol."
::= { xcvrCrntPMEntry 113 }
xcvrCrntPMFCSETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets with bad FCS
or alignment error."
::= { xcvrCrntPMEntry 114 }
xcvrCrntPMFCSEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets with
bad FCS or alignment error."
::= { xcvrCrntPMEntry 115 }
xcvrCrntPMFRDRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of dropped frames due to lack of resources or
otherwise. Note that this number is not necessarily the number
of frames dropped; it is just the number of times that it
could be detected. This object applies only to transceiver
ports provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 116 }
xcvrCrntPMFRDRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of dropped packets."
::= { xcvrCrntPMEntry 117 }
xcvrCrntPMFRDRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of dropped
packets."
::= { xcvrCrntPMEntry 118 }
xcvrCrntPMUSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets long (excluding framing bits, but including FCS octets)
and were otherwise well formed. This object applies only to
transceiver ports provisioned for the 10 gigabit ethernet LAN
protocol."
::= { xcvrCrntPMEntry 119 }
xcvrCrntPMUSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of undersized packets."
::= { xcvrCrntPMEntry 120 }
xcvrCrntPMUSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of undersized
packets."
::= { xcvrCrntPMEntry 121 }
xcvrCrntPMOSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were longer than 9600
octets (excluding framing bits, but including FCS octets) and
were otherwise well formed. This object applies only to
transceiver ports provisioned for the 10 gigabit ethernet LAN
protocol."
::= { xcvrCrntPMEntry 122 }
xcvrCrntPMOSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of oversized packets."
::= { xcvrCrntPMEntry 123 }
xcvrCrntPMOSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of oversized
packets."
::= { xcvrCrntPMEntry 124 }
xcvrCrntPMFRGTValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets in length (excluding framing bits but including FCS
octets) and had either a bad Frame Check Sequence (FCS) with
an integral number of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error). This object
applies only to transceiver ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 125 }
xcvrCrntPMFRGTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of received packet
fragments."
::= { xcvrCrntPMEntry 126 }
xcvrCrntPMFRGTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of received
packet fragments."
::= { xcvrCrntPMEntry 127 }
xcvrCrntPMJABRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were longer than
14336 9600 octets (excluding framing bits, but including FCS
octets), and had either a bad Frame Check Sequence (FCS) with
an integral number of octets (FCS Error) or a bad FCS with
non-integral number of octets (Alignment Error). This object
applies only to transceiver ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrCrntPMEntry 128 }
xcvrCrntPMJABRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of received jabbers."
::= { xcvrCrntPMEntry 129 }
xcvrCrntPMJABRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of received
jabbers."
::= { xcvrCrntPMEntry 130 }
xcvrCrntPMOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTN digital wrapper layer errored blocks."
::= { xcvrCrntPMEntry 131 }
xcvrCrntPMOTUEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
errored blocks value."
::= { xcvrCrntPMEntry 132 }
xcvrCrntPMOTUEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer errored blocks value."
::= { xcvrCrntPMEntry 133 }
xcvrCrntPMOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTN digital wrapper layer background block
errors."
::= { xcvrCrntPMEntry 134 }
xcvrCrntPMOTUBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
background block errors."
::= { xcvrCrntPMEntry 135 }
xcvrCrntPMOTUBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer background block errors value."
::= { xcvrCrntPMEntry 136 }
xcvrCrntPMOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the OTN digital wrapper
layer."
::= { xcvrCrntPMEntry 137 }
xcvrCrntPMOTUESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
errored seconds value."
::= { xcvrCrntPMEntry 138 }
xcvrCrntPMOTUESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer errored seconds value."
::= { xcvrCrntPMEntry 139 }
xcvrCrntPMOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the OTN digital
wrapper layer."
::= { xcvrCrntPMEntry 140 }
xcvrCrntPMOTUSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
severely errored seconds value."
::= { xcvrCrntPMEntry 141 }
xcvrCrntPMOTUSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer severely errored seconds value."
::= { xcvrCrntPMEntry 142 }
xcvrCrntPMOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Out-Of-Frame seconds at the OTN digital wrapper
layer."
::= { xcvrCrntPMEntry 143 }
xcvrCrntPMOTUOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
Out-Of-Frame seconds value."
::= { xcvrCrntPMEntry 144 }
xcvrCrntPMOTUOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer Out-of-Frame seconds value."
::= { xcvrCrntPMEntry 145 }
xcvrCrntPMSupplyVoltage2Value OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A second supply voltage value on the transceiver."
::= { xcvrCrntPMEntry 146 }
xcvrCrntPMSupplyVoltage2TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the second supply voltage value."
::= { xcvrCrntPMEntry 147 }
xcvrCrntPMSupplyVoltage2Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided second supply voltage
value."
::= { xcvrCrntPMEntry 148 }
xcvrCrntPMCVSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMCVSValue object
to 0."
::= { xcvrCrntPMEntry 149 }
xcvrCrntPMESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMESSValue object
to 0."
::= { xcvrCrntPMEntry 150 }
xcvrCrntPMSESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMSESSValue object
to 0."
::= { xcvrCrntPMEntry 151 }
xcvrCrntPMSEFSSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMSEFSSValue
object to 0."
::= { xcvrCrntPMEntry 152 }
xcvrCrntPMRSEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMRSEBValue object
to 0."
::= { xcvrCrntPMEntry 153 }
xcvrCrntPMRSBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMRSBBEValue
object to 0."
::= { xcvrCrntPMEntry 154 }
xcvrCrntPMRSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMRSESValue object
to 0."
::= { xcvrCrntPMEntry 155 }
xcvrCrntPMRSSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMRSSESValue
object to 0."
::= { xcvrCrntPMEntry 156 }
xcvrCrntPMRSOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMRSOFSValue
object to 0."
::= { xcvrCrntPMEntry 157 }
xcvrCrntPMCVInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMCVValue object
to 0."
::= { xcvrCrntPMEntry 158 }
xcvrCrntPMESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMESValue object
to 0."
::= { xcvrCrntPMEntry 159 }
xcvrCrntPMSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMSESValue object
to 0."
::= { xcvrCrntPMEntry 160 }
xcvrCrntPMINVBLKInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMINVBLKValue
object to 0."
::= { xcvrCrntPMEntry 161 }
xcvrCrntPMNBITCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMNBITCRValue
object to 0."
::= { xcvrCrntPMEntry 162 }
xcvrCrntPMNBYTCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMNBYTCRValue
object to 0."
::= { xcvrCrntPMEntry 163 }
xcvrCrntPMUNCRCDWInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMUNCRCDWValue
object to 0."
::= { xcvrCrntPMEntry 164 }
xcvrCrntPMFCSEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMFCSEValue object
to 0."
::= { xcvrCrntPMEntry 165 }
xcvrCrntPMFRDRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMFRDRValue object
to 0."
::= { xcvrCrntPMEntry 166 }
xcvrCrntPMUSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMUSIZEValue
object to 0."
::= { xcvrCrntPMEntry 167 }
xcvrCrntPMOSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOSIZEValue
object to 0."
::= { xcvrCrntPMEntry 168 }
xcvrCrntPMFRGTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMFRGTValue object
to 0."
::= { xcvrCrntPMEntry 169 }
xcvrCrntPMJABRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMJABRValue object
to 0."
::= { xcvrCrntPMEntry 170 }
xcvrCrntPMOTUEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOTUEBValue
object to 0."
::= { xcvrCrntPMEntry 171 }
xcvrCrntPMOTUBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOTUBBEValue
object to 0."
::= { xcvrCrntPMEntry 172 }
xcvrCrntPMOTUESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOTUESValue
object to 0."
::= { xcvrCrntPMEntry 173 }
xcvrCrntPMOTUSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOTUSESValue
object to 0."
::= { xcvrCrntPMEntry 174 }
xcvrCrntPMOTUOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOTUOFSValue
object to 0."
::= { xcvrCrntPMEntry 175 }
xcvrCrntPMUASSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the section layer.
This object applies only to transciever ports provisioned for
a SONET OC-N protocol."
::= { xcvrCrntPMEntry 176 }
xcvrCrntPMUASSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer unavailable
seconds value."
::= { xcvrCrntPMEntry 177 }
xcvrCrntPMUASSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer
unavailable seconds value."
::= { xcvrCrntPMEntry 178 }
xcvrCrntPMUASSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMUASSValue
object to 0."
::= { xcvrCrntPMEntry 179 }
xcvrCrntPMRSUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section unavailable seconds.
This object applies only to transciever ports provisioned for
a SDH STM-N protocol."
::= { xcvrCrntPMEntry 180 }
xcvrCrntPMRSUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section
unavailable seconds value."
::= { xcvrCrntPMEntry 181 }
xcvrCrntPMRSUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
unavailable seconds value."
::= { xcvrCrntPMEntry 182 }
xcvrCrntPMRSUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMRSUASValue
object to 0."
::= { xcvrCrntPMEntry 183 }
xcvrCrntPMUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds. This object applies
only to transciever ports provisioned for the gigabit ethernet
protocol or a fiber channel protocol."
::= { xcvrCrntPMEntry 184 }
xcvrCrntPMUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the unavailable seconds
value."
::= { xcvrCrntPMEntry 185 }
xcvrCrntPMUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided unavailable
seconds value."
::= { xcvrCrntPMEntry 186 }
xcvrCrntPMUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMUASValue
object to 0."
::= { xcvrCrntPMEntry 187 }
xcvrCrntPMOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the OTN digital
wrapper layer."
::= { xcvrCrntPMEntry 188 }
xcvrCrntPMOTUUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
unavailable seconds value."
::= { xcvrCrntPMEntry 189 }
xcvrCrntPMOTUUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer unavailable seconds value."
::= { xcvrCrntPMEntry 190 }
xcvrCrntPMOTUUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOTUUASValue
object to 0."
::= { xcvrCrntPMEntry 191 }
xcvrCrntPMOTNBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous BER of transciever ports provisioned for the 10 gigabit
ethernet LAN with FEC protocol."
::= { xcvrCrntPMEntry 192 }
xcvrCrntPMOTNBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous BER."
::= { xcvrCrntPMEntry 193 }
xcvrCrntPMOTNBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous BER."
::= { xcvrCrntPMEntry 194 }
xcvrCrntPMOTNBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOTNBERValue
object to 0."
::= { xcvrCrntPMEntry 195 }
xcvrCrntPMOTNAVGBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average/interval BER of transciever ports provisioned for the 10 gigabit
ethernet LAN with FEC protocol."
::= { xcvrCrntPMEntry 196 }
xcvrCrntPMOTNAVGBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average/interval BER."
::= { xcvrCrntPMEntry 197 }
xcvrCrntPMOTNAVGBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average/interval BER."
::= { xcvrCrntPMEntry 198 }
xcvrCrntPMOTNAVGBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOTNAVGBERValue
object to 0."
::= { xcvrCrntPMEntry 199 }
xcvrCrntPMNBITCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bits corrected. This object
applies only to transciever ports provisioned for a protocol
that includes Forward Error Correction (FEC)."
::= { xcvrCrntPMEntry 200 }
xcvrCrntPMNBITCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bits
corrected value."
::= { xcvrCrntPMEntry 201 }
xcvrCrntPMNBITCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number
of bits corrected value."
::= { xcvrCrntPMEntry 202 }
xcvrCrntPMNBITCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMNBITCR64BitValue
object to 0."
::= { xcvrCrntPMEntry 203 }
xcvrCrntPMNBYTCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bytes corrected. This object
applies only to transciever ports provisioned for a protocol
that includes Forward Error Correction (FEC)."
::= { xcvrCrntPMEntry 204 }
xcvrCrntPMNBYTCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bytes
corrected value."
::= { xcvrCrntPMEntry 205 }
xcvrCrntPMNBYTCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of
bytes corrected value."
::= { xcvrCrntPMEntry 206 }
xcvrCrntPMNBYTCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMNBYTCR64BitValue
object to 0."
::= { xcvrCrntPMEntry 207 }
xcvrCrntPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { xcvrCrntPMEntry 208 }
xcvrCrntPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { xcvrCrntPMEntry 209 }
xcvrCrntPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { xcvrCrntPMEntry 210 }
xcvrCrntPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOPRMinValue
object to 0."
::= { xcvrCrntPMEntry 211 }
xcvrCrntPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { xcvrCrntPMEntry 212 }
xcvrCrntPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { xcvrCrntPMEntry 213 }
xcvrCrntPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { xcvrCrntPMEntry 214 }
xcvrCrntPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOPRMaxValue
object to 0."
::= { xcvrCrntPMEntry 215 }
xcvrCrntPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { xcvrCrntPMEntry 216 }
xcvrCrntPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { xcvrCrntPMEntry 217 }
xcvrCrntPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { xcvrCrntPMEntry 218 }
xcvrCrntPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOPRAvgValue
object to 0."
::= { xcvrCrntPMEntry 219 }
xcvrCrntPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { xcvrCrntPMEntry 220 }
xcvrCrntPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { xcvrCrntPMEntry 221 }
xcvrCrntPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { xcvrCrntPMEntry 222 }
xcvrCrntPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOPTMinValue
object to 0."
::= { xcvrCrntPMEntry 223 }
xcvrCrntPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { xcvrCrntPMEntry 224 }
xcvrCrntPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { xcvrCrntPMEntry 225 }
xcvrCrntPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { xcvrCrntPMEntry 226 }
xcvrCrntPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOPTMaxValue
object to 0."
::= { xcvrCrntPMEntry 227 }
xcvrCrntPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { xcvrCrntPMEntry 228 }
xcvrCrntPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { xcvrCrntPMEntry 229 }
xcvrCrntPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { xcvrCrntPMEntry 230 }
xcvrCrntPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrCrntPMOPTAvgValue
object to 0."
::= { xcvrCrntPMEntry 231 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical Optical Transceiver
-- Performance Monitoring statistics
--
-- A listing of historical transceiver PM values are contained in the
-- xcvrHistPMTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each set of historical transceiver
-- PM data.
--
-- The following table lists the objects in each entry of the xcvrHistPMTable.
-----------------------------------------------------------------------
xcvrHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF XcvrHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the optical transceiver facilities on the NE."
::= { performance 4 }
xcvrHistPMEntry OBJECT-TYPE
SYNTAX XcvrHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the optical transceiver historical
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a historical
measurement interval for a given optical transceiver."
INDEX { xcvrHistPMTypeIdx,
xcvrHistPMShelfIdx,
xcvrHistPMSlotIdx,
xcvrHistPMIdx,
xcvrHistPMIntervalTypeIdx,
xcvrHistPMIntervalIdx }
::= { xcvrHistPMTable 1 }
XcvrHistPMEntry ::= SEQUENCE { xcvrHistPMTypeIdx XcvrType,
xcvrHistPMShelfIdx INTEGER,
xcvrHistPMSlotIdx INTEGER,
xcvrHistPMIdx INTEGER,
xcvrHistPMIntervalTypeIdx PMIntervalType,
xcvrHistPMIntervalIdx INTEGER,
xcvrHistPMOPRValue FixedX10,
xcvrHistPMOPRTimeStamp DateAndTime,
xcvrHistPMOPRValidity PMValidity,
xcvrHistPMOPTValue FixedX10,
xcvrHistPMOPTTimeStamp DateAndTime,
xcvrHistPMOPTValidity PMValidity,
xcvrHistPMTempValue INTEGER,
xcvrHistPMTempTimeStamp DateAndTime,
xcvrHistPMTempValidity PMValidity,
xcvrHistPMSupplyVoltageValue FixedX10,
xcvrHistPMSupplyVoltageTimeStamp DateAndTime,
xcvrHistPMSupplyVoltageValidity PMValidity,
xcvrHistPMLBCValue INTEGER,
xcvrHistPMLBCTimeStamp DateAndTime,
xcvrHistPMLBCValidity PMValidity,
xcvrHistPMCVSValue Unsigned32,
xcvrHistPMCVSTimeStamp DateAndTime,
xcvrHistPMCVSValidity PMValidity,
xcvrHistPMESSValue Unsigned32,
xcvrHistPMESSTimeStamp DateAndTime,
xcvrHistPMESSValidity PMValidity,
xcvrHistPMSESSValue Unsigned32,
xcvrHistPMSESSTimeStamp DateAndTime,
xcvrHistPMSESSValidity PMValidity,
xcvrHistPMSEFSSValue Unsigned32,
xcvrHistPMSEFSSTimeStamp DateAndTime,
xcvrHistPMSEFSSValidity PMValidity,
xcvrHistPMRSEBValue Unsigned32,
xcvrHistPMRSEBTimeStamp DateAndTime,
xcvrHistPMRSEBValidity PMValidity,
xcvrHistPMRSBBEValue Unsigned32,
xcvrHistPMRSBBETimeStamp DateAndTime,
xcvrHistPMRSBBEValidity PMValidity,
xcvrHistPMRSESValue Unsigned32,
xcvrHistPMRSESTimeStamp DateAndTime,
xcvrHistPMRSESValidity PMValidity,
xcvrHistPMRSSESValue Unsigned32,
xcvrHistPMRSSESTimeStamp DateAndTime,
xcvrHistPMRSSESValidity PMValidity,
xcvrHistPMRSOFSValue Unsigned32,
xcvrHistPMRSOFSTimeStamp DateAndTime,
xcvrHistPMRSOFSValidity PMValidity,
xcvrHistPMCVValue Unsigned32,
xcvrHistPMCVTimeStamp DateAndTime,
xcvrHistPMCVValidity PMValidity,
xcvrHistPMESValue Unsigned32,
xcvrHistPMESTimeStamp DateAndTime,
xcvrHistPMESValidity PMValidity,
xcvrHistPMSESValue Unsigned32,
xcvrHistPMSESTimeStamp DateAndTime,
xcvrHistPMSESValidity PMValidity,
xcvrHistPMINVBLKValue Unsigned32,
xcvrHistPMINVBLKTimeStamp DateAndTime,
xcvrHistPMINVBLKValidity PMValidity,
xcvrHistPMNBITCRValue Unsigned32,
xcvrHistPMNBITCRTimeStamp DateAndTime,
xcvrHistPMNBITCRValidity PMValidity,
xcvrHistPMNBYTCRValue Unsigned32,
xcvrHistPMNBYTCRTimeStamp DateAndTime,
xcvrHistPMNBYTCRValidity PMValidity,
xcvrHistPMUNCRCDWValue Unsigned32,
xcvrHistPMUNCRCDWTimeStamp DateAndTime,
xcvrHistPMUNCRCDWValidity PMValidity,
xcvrHistPMTBYCRXValue Unsigned64,
xcvrHistPMTBYCRXTimeStamp DateAndTime,
xcvrHistPMTBYCRXValidity PMValidity,
xcvrHistPMTBYCRXInitialize InitializeCmd,
xcvrHistPMTFRCRXValue Unsigned64,
xcvrHistPMTFRCRXTimeStamp DateAndTime,
xcvrHistPMTFRCRXValidity PMValidity,
xcvrHistPMTFRCRXInitialize InitializeCmd,
xcvrHistPMBCSTValue Unsigned64,
xcvrHistPMBCSTTimeStamp DateAndTime,
xcvrHistPMBCSTValidity PMValidity,
xcvrHistPMBCSTInitialize InitializeCmd,
xcvrHistPMMCSTValue Unsigned64,
xcvrHistPMMCSTTimeStamp DateAndTime,
xcvrHistPMMCSTValidity PMValidity,
xcvrHistPMMCSTInitialize InitializeCmd,
xcvrHistPMSIZE64Value Unsigned64,
xcvrHistPMSIZE64TimeStamp DateAndTime,
xcvrHistPMSIZE64Validity PMValidity,
xcvrHistPMSIZE64Initialize InitializeCmd,
xcvrHistPMSIZE65To127Value Unsigned64,
xcvrHistPMSIZE65To127TimeStamp DateAndTime,
xcvrHistPMSIZE65To127Validity PMValidity,
xcvrHistPMSIZE65To127Initialize InitializeCmd,
xcvrHistPMSIZE128To255Value Unsigned64,
xcvrHistPMSIZE128To255TimeStamp DateAndTime,
xcvrHistPMSIZE128To255Validity PMValidity,
xcvrHistPMSIZE128To255Initialize InitializeCmd,
xcvrHistPMSIZE256To511Value Unsigned64,
xcvrHistPMSIZE256To511TimeStamp DateAndTime,
xcvrHistPMSIZE256To511Validity PMValidity,
xcvrHistPMSIZE256To511Initialize InitializeCmd,
xcvrHistPMSIZE512To1023Value Unsigned64,
xcvrHistPMSIZE512To1023TimeStamp DateAndTime,
xcvrHistPMSIZE512To1023Validity PMValidity,
xcvrHistPMSIZE512To1023Initialize InitializeCmd,
xcvrHistPMSIZE1024To1518Value Unsigned64,
xcvrHistPMSIZE1024To1518TimeStamp DateAndTime,
xcvrHistPMSIZE1024To1518Validity PMValidity,
xcvrHistPMSIZE1024To1518Initialize InitializeCmd,
xcvrHistPMSIZEOver1518Value Unsigned64,
xcvrHistPMSIZEOver1518TimeStamp DateAndTime,
xcvrHistPMSIZEOver1518Validity PMValidity,
xcvrHistPMSIZEOver1518Initialize InitializeCmd,
xcvrHistPMFCSEValue Unsigned32,
xcvrHistPMFCSETimeStamp DateAndTime,
xcvrHistPMFCSEValidity PMValidity,
xcvrHistPMFRDRValue Unsigned32,
xcvrHistPMFRDRTimeStamp DateAndTime,
xcvrHistPMFRDRValidity PMValidity,
xcvrHistPMUSIZEValue Unsigned32,
xcvrHistPMUSIZETimeStamp DateAndTime,
xcvrHistPMUSIZEValidity PMValidity,
xcvrHistPMOSIZEValue Unsigned32,
xcvrHistPMOSIZETimeStamp DateAndTime,
xcvrHistPMOSIZEValidity PMValidity,
xcvrHistPMFRGTValue Unsigned32,
xcvrHistPMFRGTTimeStamp DateAndTime,
xcvrHistPMFRGTValidity PMValidity,
xcvrHistPMJABRValue Unsigned32,
xcvrHistPMJABRTimeStamp DateAndTime,
xcvrHistPMJABRValidity PMValidity,
xcvrHistPMOTUEBValue Unsigned32,
xcvrHistPMOTUEBTimeStamp DateAndTime,
xcvrHistPMOTUEBValidity PMValidity,
xcvrHistPMOTUBBEValue Unsigned32,
xcvrHistPMOTUBBETimeStamp DateAndTime,
xcvrHistPMOTUBBEValidity PMValidity,
xcvrHistPMOTUESValue Unsigned32,
xcvrHistPMOTUESTimeStamp DateAndTime,
xcvrHistPMOTUESValidity PMValidity,
xcvrHistPMOTUSESValue Unsigned32,
xcvrHistPMOTUSESTimeStamp DateAndTime,
xcvrHistPMOTUSESValidity PMValidity,
xcvrHistPMOTUOFSValue Unsigned32,
xcvrHistPMOTUOFSTimeStamp DateAndTime,
xcvrHistPMOTUOFSValidity PMValidity,
xcvrHistPMSupplyVoltage2Value FixedX10,
xcvrHistPMSupplyVoltage2TimeStamp DateAndTime,
xcvrHistPMSupplyVoltage2Validity PMValidity,
xcvrHistPMCVSInitialize InitializeCmd,
xcvrHistPMESSInitialize InitializeCmd,
xcvrHistPMSESSInitialize InitializeCmd,
xcvrHistPMSEFSSInitialize InitializeCmd,
xcvrHistPMRSEBInitialize InitializeCmd,
xcvrHistPMRSBBEInitialize InitializeCmd,
xcvrHistPMRSESInitialize InitializeCmd,
xcvrHistPMRSSESInitialize InitializeCmd,
xcvrHistPMRSOFSInitialize InitializeCmd,
xcvrHistPMCVInitialize InitializeCmd,
xcvrHistPMESInitialize InitializeCmd,
xcvrHistPMSESInitialize InitializeCmd,
xcvrHistPMINVBLKInitialize InitializeCmd,
xcvrHistPMNBITCRInitialize InitializeCmd,
xcvrHistPMNBYTCRInitialize InitializeCmd,
xcvrHistPMUNCRCDWInitialize InitializeCmd,
xcvrHistPMFCSEInitialize InitializeCmd,
xcvrHistPMFRDRInitialize InitializeCmd,
xcvrHistPMUSIZEInitialize InitializeCmd,
xcvrHistPMOSIZEInitialize InitializeCmd,
xcvrHistPMFRGTInitialize InitializeCmd,
xcvrHistPMJABRInitialize InitializeCmd,
xcvrHistPMOTUEBInitialize InitializeCmd,
xcvrHistPMOTUBBEInitialize InitializeCmd,
xcvrHistPMOTUESInitialize InitializeCmd,
xcvrHistPMOTUSESInitialize InitializeCmd,
xcvrHistPMOTUOFSInitialize InitializeCmd,
xcvrHistPMUASSValue Unsigned32,
xcvrHistPMUASSTimeStamp DateAndTime,
xcvrHistPMUASSValidity PMValidity,
xcvrHistPMUASSInitialize InitializeCmd,
xcvrHistPMRSUASValue Unsigned32,
xcvrHistPMRSUASTimeStamp DateAndTime,
xcvrHistPMRSUASValidity PMValidity,
xcvrHistPMRSUASInitialize InitializeCmd,
xcvrHistPMUASValue Unsigned32,
xcvrHistPMUASTimeStamp DateAndTime,
xcvrHistPMUASValidity PMValidity,
xcvrHistPMUASInitialize InitializeCmd,
xcvrHistPMOTUUASValue Unsigned32,
xcvrHistPMOTUUASTimeStamp DateAndTime,
xcvrHistPMOTUUASValidity PMValidity,
xcvrHistPMOTUUASInitialize InitializeCmd,
xcvrHistPMOTNBERValue DisplayString,
xcvrHistPMOTNBERTimeStamp DateAndTime,
xcvrHistPMOTNBERValidity PMValidity,
xcvrHistPMOTNBERInitialize InitializeCmd,
xcvrHistPMOTNAVGBERValue DisplayString,
xcvrHistPMOTNAVGBERTimeStamp DateAndTime,
xcvrHistPMOTNAVGBERValidity PMValidity,
xcvrHistPMOTNAVGBERInitialize InitializeCmd,
xcvrHistPMNBITCR64BitValue Unsigned64,
xcvrHistPMNBITCR64BitTimeStamp DateAndTime,
xcvrHistPMNBITCR64BitValidity PMValidity,
xcvrHistPMNBITCR64BitInitialize InitializeCmd,
xcvrHistPMNBYTCR64BitValue Unsigned64,
xcvrHistPMNBYTCR64BitTimeStamp DateAndTime,
xcvrHistPMNBYTCR64BitValidity PMValidity,
xcvrHistPMNBYTCR64BitInitialize InitializeCmd,
xcvrHistPMOPRMinValue FixedX10,
xcvrHistPMOPRMinTimeStamp DateAndTime,
xcvrHistPMOPRMinValidity PMValidity,
xcvrHistPMOPRMinInitialize InitializeCmd,
xcvrHistPMOPRMaxValue FixedX10,
xcvrHistPMOPRMaxTimeStamp DateAndTime,
xcvrHistPMOPRMaxValidity PMValidity,
xcvrHistPMOPRMaxInitialize InitializeCmd,
xcvrHistPMOPRAvgValue FixedX10,
xcvrHistPMOPRAvgTimeStamp DateAndTime,
xcvrHistPMOPRAvgValidity PMValidity,
xcvrHistPMOPRAvgInitialize InitializeCmd,
xcvrHistPMOPTMinValue FixedX10,
xcvrHistPMOPTMinTimeStamp DateAndTime,
xcvrHistPMOPTMinValidity PMValidity,
xcvrHistPMOPTMinInitialize InitializeCmd,
xcvrHistPMOPTMaxValue FixedX10,
xcvrHistPMOPTMaxTimeStamp DateAndTime,
xcvrHistPMOPTMaxValidity PMValidity,
xcvrHistPMOPTMaxInitialize InitializeCmd,
xcvrHistPMOPTAvgValue FixedX10,
xcvrHistPMOPTAvgTimeStamp DateAndTime,
xcvrHistPMOPTAvgValidity PMValidity,
xcvrHistPMOPTAvgInitialize InitializeCmd }
xcvrHistPMTypeIdx OBJECT-TYPE
SYNTAX XcvrType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the optical transceiver targeted for PMs."
::= { xcvrHistPMEntry 1 }
xcvrHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the optical transceiver
targeted for PMs is provisioned."
::= { xcvrHistPMEntry 2 }
xcvrHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the optical transceiver
targeted for PMs is provisioned."
::= { xcvrHistPMEntry 3 }
xcvrHistPMIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the transceiver port targeted for PMs."
::= { xcvrHistPMEntry 4 }
xcvrHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { xcvrHistPMEntry 5 }
xcvrHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { xcvrHistPMEntry 6 }
xcvrHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the transceiver."
::= { xcvrHistPMEntry 7 }
xcvrHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { xcvrHistPMEntry 8 }
xcvrHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { xcvrHistPMEntry 9 }
xcvrHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the
transceiver."
::= { xcvrHistPMEntry 10 }
xcvrHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { xcvrHistPMEntry 11 }
xcvrHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { xcvrHistPMEntry 12 }
xcvrHistPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical transceiver temperature."
::= { xcvrHistPMEntry 13 }
xcvrHistPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { xcvrHistPMEntry 14 }
xcvrHistPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { xcvrHistPMEntry 15 }
xcvrHistPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The transceiver supply voltage."
::= { xcvrHistPMEntry 16 }
xcvrHistPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { xcvrHistPMEntry 17 }
xcvrHistPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { xcvrHistPMEntry 18 }
xcvrHistPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The transceiver laser bias current."
::= { xcvrHistPMEntry 19 }
xcvrHistPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { xcvrHistPMEntry 20 }
xcvrHistPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { xcvrHistPMEntry 21 }
xcvrHistPMCVSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations at the section layer. This
object applies only to transciever ports provisioned for a
SONET OC-N protocol."
::= { xcvrHistPMEntry 22 }
xcvrHistPMCVSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer coding violations
value."
::= { xcvrHistPMEntry 23 }
xcvrHistPMCVSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer coding
violations value."
::= { xcvrHistPMEntry 24 }
xcvrHistPMESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the section layer. This object
applies only to transciever ports provisioned for a SONET OC-N
protocol."
::= { xcvrHistPMEntry 25 }
xcvrHistPMESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer errored seconds
value."
::= { xcvrHistPMEntry 26 }
xcvrHistPMESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer errored
seconds value."
::= { xcvrHistPMEntry 27 }
xcvrHistPMSESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the section layer.
This object applies only to transciever ports provisioned for
a SONET OC-N protocol."
::= { xcvrHistPMEntry 28 }
xcvrHistPMSESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
seconds value."
::= { xcvrHistPMEntry 29 }
xcvrHistPMSESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored seconds value."
::= { xcvrHistPMEntry 30 }
xcvrHistPMSEFSSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored framing seconds at the section
layer. This object applies only to transciever ports
provisioned for a SONET OC-N protocol."
::= { xcvrHistPMEntry 31 }
xcvrHistPMSEFSSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
framing seconds value."
::= { xcvrHistPMEntry 32 }
xcvrHistPMSEFSSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored framing seconds value."
::= { xcvrHistPMEntry 33 }
xcvrHistPMRSEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section errored blocks. This object
applies only to transciever ports provisioned for a SDH STM-N
protocol."
::= { xcvrHistPMEntry 34 }
xcvrHistPMRSEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section errored
blocks value."
::= { xcvrHistPMEntry 35 }
xcvrHistPMRSEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
errored blocks value."
::= { xcvrHistPMEntry 36 }
xcvrHistPMRSBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section background block errors. This
object applies only to transciever ports provisioned for a SDH
STM-N protocol."
::= { xcvrHistPMEntry 37 }
xcvrHistPMRSBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section background
block errors value."
::= { xcvrHistPMEntry 38 }
xcvrHistPMRSBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
background block errors value."
::= { xcvrHistPMEntry 39 }
xcvrHistPMRSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section errored seconds. This object
applies only to transciever ports provisioned for a SDH STM-N
protocol."
::= { xcvrHistPMEntry 40 }
xcvrHistPMRSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section errored
seconds value."
::= { xcvrHistPMEntry 41 }
xcvrHistPMRSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
errored seconds value."
::= { xcvrHistPMEntry 42 }
xcvrHistPMRSSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section severely errored seconds.
This object applies only to transciever ports provisioned for
a SDH STM-N protocol."
::= { xcvrHistPMEntry 43 }
xcvrHistPMRSSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section severely
errored seconds value."
::= { xcvrHistPMEntry 44 }
xcvrHistPMRSSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
severely errored seconds value."
::= { xcvrHistPMEntry 45 }
xcvrHistPMRSOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section out-of-frame seconds. This
object applies only to transciever ports provisioned for a SDH
STM-N protocol."
::= { xcvrHistPMEntry 46 }
xcvrHistPMRSOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section
out-of-frame seconds value."
::= { xcvrHistPMEntry 47 }
xcvrHistPMRSOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
out-of-frame seconds value."
::= { xcvrHistPMEntry 48 }
xcvrHistPMCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations. This object applies only to
transciever ports provisioned for the gigabit ethernet
protocol or a fiber channel protocol."
::= { xcvrHistPMEntry 49 }
xcvrHistPMCVTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the coding violations value."
::= { xcvrHistPMEntry 50 }
xcvrHistPMCVValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided coding violations
value."
::= { xcvrHistPMEntry 51 }
xcvrHistPMESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds. This object applies only to
transciever ports provisioned for an ethernet protocol
or a fiber channel protocol."
::= { xcvrHistPMEntry 52 }
xcvrHistPMESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the errored seconds value."
::= { xcvrHistPMEntry 53 }
xcvrHistPMESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided errored seconds value."
::= { xcvrHistPMEntry 54 }
xcvrHistPMSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds. This object applies
only to transciever ports provisioned for an ethernet
protocol or a fiber channel protocol."
::= { xcvrHistPMEntry 55 }
xcvrHistPMSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the severely errored seconds
value."
::= { xcvrHistPMEntry 56 }
xcvrHistPMSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided severely errored
seconds value."
::= { xcvrHistPMEntry 57 }
xcvrHistPMINVBLKValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of invalid blocks. This object applies only to
transciever ports provisioned for the 10 gigabit ethernet LAN
protocol."
::= { xcvrHistPMEntry 58 }
xcvrHistPMINVBLKTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the invalid blocks value."
::= { xcvrHistPMEntry 59 }
xcvrHistPMINVBLKValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided invalid blocks value."
::= { xcvrHistPMEntry 60 }
xcvrHistPMNBITCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bits corrected. This object
applies only to transciever ports provisioned for a protocol
that includes Forward Error Correction (FEC)."
::= { xcvrHistPMEntry 61 }
xcvrHistPMNBITCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bits corrected
value."
::= { xcvrHistPMEntry 62 }
xcvrHistPMNBITCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bits
corrected value."
::= { xcvrHistPMEntry 63 }
xcvrHistPMNBYTCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bytes corrected. This object
applies only to transciever ports provisioned for a protocol
that includes Forward Error Correction (FEC)."
::= { xcvrHistPMEntry 64 }
xcvrHistPMNBYTCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bytes corrected
value."
::= { xcvrHistPMEntry 65 }
xcvrHistPMNBYTCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bytes
corrected value."
::= { xcvrHistPMEntry 66 }
xcvrHistPMUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of uncorrectable codewords. This object
applies only to transciever ports provisioned for a protocol
that includes Forward Error Correction (FEC)."
::= { xcvrHistPMEntry 67 }
xcvrHistPMUNCRCDWTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the uncorrectable codewords value."
::= { xcvrHistPMEntry 68 }
xcvrHistPMUNCRCDWValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided uncorrectable codewords
value."
::= { xcvrHistPMEntry 69 }
xcvrHistPMTBYCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of bytes of data (including those in bad
frames) received (excluding framing bits but including FCS
bytes). This object applies only to transceiver ports
provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 70 }
xcvrHistPMTBYCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the received bytes count value."
::= { xcvrHistPMEntry 71 }
xcvrHistPMTBYCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided received bytes count
value."
::= { xcvrHistPMEntry 72 }
xcvrHistPMTBYCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMTBYCRXValue
object to 0."
::= { xcvrHistPMEntry 73 }
xcvrHistPMTFRCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of received frames (incl. bad frames,
broadcast frames, and multicast frames received). This object
applies only to transceiver ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 74 }
xcvrHistPMTFRCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the received frames count value."
::= { xcvrHistPMEntry 75 }
xcvrHistPMTFRCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided received frames count
value."
::= { xcvrHistPMEntry 76 }
xcvrHistPMTFRCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMTFRCRXValue
object to 0."
::= { xcvrHistPMEntry 77 }
xcvrHistPMBCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
the broadcast address. Note that this does not include
multicast frames. This object applies only to transceiver
ports provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 78 }
xcvrHistPMBCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the broadcast packets received
count value."
::= { xcvrHistPMEntry 79 }
xcvrHistPMBCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided broadcast packets
received count value."
::= { xcvrHistPMEntry 80 }
xcvrHistPMBCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMBCSTValue object
to 0."
::= { xcvrHistPMEntry 81 }
xcvrHistPMMCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
a multicast address. Note that this number does not include
frames directed to the broadcast address. This object applies
only to transceiver ports provisioned for the 10 gigabit
ethernet LAN protocol."
::= { xcvrHistPMEntry 82 }
xcvrHistPMMCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multicast packets received
count value."
::= { xcvrHistPMEntry 83 }
xcvrHistPMMCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multicast packets
received count value."
::= { xcvrHistPMEntry 84 }
xcvrHistPMMCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMMCSTValue object
to 0."
::= { xcvrHistPMEntry 85 }
xcvrHistPMSIZE64Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of 64 byte frames received (excluding framing
bits but including FCS octets). This object applies only to
transceiver ports provisioned for the 10 gigabit ethernet LAN
protocol."
::= { xcvrHistPMEntry 86 }
xcvrHistPMSIZE64TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of 64-byte packets
received."
::= { xcvrHistPMEntry 87 }
xcvrHistPMSIZE64Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of 64-byte
packets packets received."
::= { xcvrHistPMEntry 88 }
xcvrHistPMSIZE64Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMSIZE64Value
object to 0."
::= { xcvrHistPMEntry 89 }
xcvrHistPMSIZE65To127Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 65 to 127 bytes
inclusive in length (excluding framing bits but including FCS
octets). This object applies only to transceiver ports
provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 90 }
xcvrHistPMSIZE65To127TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 65 and
127 bytes."
::= { xcvrHistPMEntry 91 }
xcvrHistPMSIZE65To127Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 65 and 127 bytes."
::= { xcvrHistPMEntry 92 }
xcvrHistPMSIZE65To127Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMSIZE65To127Value
object to 0."
::= { xcvrHistPMEntry 93 }
xcvrHistPMSIZE128To255Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 128 to 255 bytes
inclusive in length (excluding framing bits but including FCS
octets). This object applies only to transceiver ports
provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 94 }
xcvrHistPMSIZE128To255TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 128
and 255 bytes."
::= { xcvrHistPMEntry 95 }
xcvrHistPMSIZE128To255Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 128 and 255 bytes."
::= { xcvrHistPMEntry 96 }
xcvrHistPMSIZE128To255Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
xcvrHistPMSIZE128To255Value object to 0."
::= { xcvrHistPMEntry 97 }
xcvrHistPMSIZE256To511Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 256 to 511 bytes
inclusive in length (excluding framing bits but including FCS
octets). This object applies only to transceiver ports
provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 98 }
xcvrHistPMSIZE256To511TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 256
and 511 bytes."
::= { xcvrHistPMEntry 99 }
xcvrHistPMSIZE256To511Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 256 and 511 bytes."
::= { xcvrHistPMEntry 100 }
xcvrHistPMSIZE256To511Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
xcvrHistPMSIZE256To511Value object to 0."
::= { xcvrHistPMEntry 101 }
xcvrHistPMSIZE512To1023Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 512 to 1023 bytes
inclusive in length (excluding framing bits but including FCS
octets). This object applies only to transceiver ports
provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 102 }
xcvrHistPMSIZE512To1023TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 512
and 1023 bytes."
::= { xcvrHistPMEntry 103 }
xcvrHistPMSIZE512To1023Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 512 and 1023 bytes."
::= { xcvrHistPMEntry 104 }
xcvrHistPMSIZE512To1023Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
xcvrHistPMSIZE512To1023Value object to 0."
::= { xcvrHistPMEntry 105 }
xcvrHistPMSIZE1024To1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 1024 to 1518
bytes inclusive in length (excluding framing bits but
including FCS octets). This object applies only to transceiver
ports provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 106 }
xcvrHistPMSIZE1024To1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 1024
and 1518 bytes."
::= { xcvrHistPMEntry 107 }
xcvrHistPMSIZE1024To1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 1024 and 1518 bytes."
::= { xcvrHistPMEntry 108 }
xcvrHistPMSIZE1024To1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
xcvrHistPMSIZE1024To1518Value object to 0."
::= { xcvrHistPMEntry 109 }
xcvrHistPMSIZEOver1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are greater than or
equal to 1519 bytes in length (excluding framing bits but
including FCS octets). This object applies only to transceiver
ports provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 110 }
xcvrHistPMSIZEOver1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets over 1518
bytes."
::= { xcvrHistPMEntry 111 }
xcvrHistPMSIZEOver1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets over
1518 bytes."
::= { xcvrHistPMEntry 112 }
xcvrHistPMSIZEOver1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
xcvrHistPMSIZEOver1518Value object to 0."
::= { xcvrHistPMEntry 113 }
xcvrHistPMFCSEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of packets that had a valid length but had either a
Frame Check Sequence (FCS) or a bad FCS with a non-integral
number of octets (Alignment Error) . This object applies only
to transceiver ports provisioned for the 10 gigabit ethernet
LAN protocol."
::= { xcvrHistPMEntry 114 }
xcvrHistPMFCSETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets with bad FCS
or alignment error."
::= { xcvrHistPMEntry 115 }
xcvrHistPMFCSEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets with
bad FCS or alignment error."
::= { xcvrHistPMEntry 116 }
xcvrHistPMFRDRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of dropped frames due to lack of resources or
otherwise. Note that this number is not necessarily the number
of frames dropped; it is just the number of times that it
could be detected. This object applies only to transceiver
ports provisioned for the 10 gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 117 }
xcvrHistPMFRDRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of dropped packets."
::= { xcvrHistPMEntry 118 }
xcvrHistPMFRDRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of dropped
packets."
::= { xcvrHistPMEntry 119 }
xcvrHistPMUSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets long (excluding framing bits, but including FCS octets)
and were otherwise well formed. This object applies only to
transceiver ports provisioned for the 10 gigabit ethernet LAN
protocol."
::= { xcvrHistPMEntry 120 }
xcvrHistPMUSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of undersized packets."
::= { xcvrHistPMEntry 121 }
xcvrHistPMUSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of undersized
packets."
::= { xcvrHistPMEntry 122 }
xcvrHistPMOSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were longer than 9600
octets (excluding framing bits, but including FCS octets) and
were otherwise well formed. This object applies only to
transceiver ports provisioned for the 10 gigabit ethernet LAN
protocol."
::= { xcvrHistPMEntry 123 }
xcvrHistPMOSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of oversized packets."
::= { xcvrHistPMEntry 124 }
xcvrHistPMOSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of oversized
packets."
::= { xcvrHistPMEntry 125 }
xcvrHistPMFRGTValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets in length (excluding framing bits but including FCS
octets) and had either a bad Frame Check Sequence (FCS) with
an integral number of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error). This object
applies only to transceiver ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 126 }
xcvrHistPMFRGTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of received packet
fragments."
::= { xcvrHistPMEntry 127 }
xcvrHistPMFRGTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of received
packet fragments."
::= { xcvrHistPMEntry 128 }
xcvrHistPMJABRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were longer than
14336 9600 octets (excluding framing bits, but including FCS
octets), and had either a bad Frame Check Sequence (FCS) with
an integral number of octets (FCS Error) or a bad FCS with
non-integral number of octets (Alignment Error). This object
applies only to transceiver ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrHistPMEntry 129 }
xcvrHistPMJABRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of received jabbers."
::= { xcvrHistPMEntry 130 }
xcvrHistPMJABRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of received
jabbers."
::= { xcvrHistPMEntry 131 }
xcvrHistPMOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTN digital wrapper layer errored blocks."
::= { xcvrHistPMEntry 132 }
xcvrHistPMOTUEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
errored blocks value."
::= { xcvrHistPMEntry 133 }
xcvrHistPMOTUEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer errored blocks value."
::= { xcvrHistPMEntry 134 }
xcvrHistPMOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTN digital wrapper layer background block
errors."
::= { xcvrHistPMEntry 135 }
xcvrHistPMOTUBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
background block errors."
::= { xcvrHistPMEntry 136 }
xcvrHistPMOTUBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer background block errors value."
::= { xcvrHistPMEntry 137 }
xcvrHistPMOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the OTN digital wrapper
layer."
::= { xcvrHistPMEntry 138 }
xcvrHistPMOTUESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
errored seconds value."
::= { xcvrHistPMEntry 139 }
xcvrHistPMOTUESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer errored seconds value."
::= { xcvrHistPMEntry 140 }
xcvrHistPMOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the OTN digital
wrapper layer."
::= { xcvrHistPMEntry 141 }
xcvrHistPMOTUSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
severely errored seconds value."
::= { xcvrHistPMEntry 142 }
xcvrHistPMOTUSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer severely errored seconds value."
::= { xcvrHistPMEntry 143 }
xcvrHistPMOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Out-Of-Frame seconds at the OTN digital wrapper
layer."
::= { xcvrHistPMEntry 144 }
xcvrHistPMOTUOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
Out-Of-Frame seconds value."
::= { xcvrHistPMEntry 145 }
xcvrHistPMOTUOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer Out-of-Frame seconds value."
::= { xcvrHistPMEntry 146 }
xcvrHistPMSupplyVoltage2Value OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A second supply voltage value on the transceiver."
::= { xcvrHistPMEntry 147 }
xcvrHistPMSupplyVoltage2TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the second supply voltage value."
::= { xcvrHistPMEntry 148 }
xcvrHistPMSupplyVoltage2Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided second supply voltage
value."
::= { xcvrHistPMEntry 149 }
xcvrHistPMCVSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMCVSValue object
to 0."
::= { xcvrHistPMEntry 150 }
xcvrHistPMESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMESSValue object
to 0."
::= { xcvrHistPMEntry 151 }
xcvrHistPMSESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMSESSValue object
to 0."
::= { xcvrHistPMEntry 152 }
xcvrHistPMSEFSSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMSEFSSValue
object to 0."
::= { xcvrHistPMEntry 153 }
xcvrHistPMRSEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMRSEBValue object
to 0."
::= { xcvrHistPMEntry 154 }
xcvrHistPMRSBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMRSBBEValue
object to 0."
::= { xcvrHistPMEntry 155 }
xcvrHistPMRSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMRSESValue object
to 0."
::= { xcvrHistPMEntry 156 }
xcvrHistPMRSSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMRSSESValue
object to 0."
::= { xcvrHistPMEntry 157 }
xcvrHistPMRSOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMRSOFSValue
object to 0."
::= { xcvrHistPMEntry 158 }
xcvrHistPMCVInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMCVValue object
to 0."
::= { xcvrHistPMEntry 159 }
xcvrHistPMESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMESValue object
to 0."
::= { xcvrHistPMEntry 160 }
xcvrHistPMSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMSESValue object
to 0."
::= { xcvrHistPMEntry 161 }
xcvrHistPMINVBLKInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMINVBLKValue
object to 0."
::= { xcvrHistPMEntry 162 }
xcvrHistPMNBITCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMNBITCRValue
object to 0."
::= { xcvrHistPMEntry 163 }
xcvrHistPMNBYTCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMNBYTCRValue
object to 0."
::= { xcvrHistPMEntry 164 }
xcvrHistPMUNCRCDWInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMUNCRCDWValue
object to 0."
::= { xcvrHistPMEntry 165 }
xcvrHistPMFCSEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMFCSEValue object
to 0."
::= { xcvrHistPMEntry 166 }
xcvrHistPMFRDRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMFRDRValue object
to 0."
::= { xcvrHistPMEntry 167 }
xcvrHistPMUSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMUSIZEValue
object to 0."
::= { xcvrHistPMEntry 168 }
xcvrHistPMOSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOSIZEValue
object to 0."
::= { xcvrHistPMEntry 169 }
xcvrHistPMFRGTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMFRGTValue object
to 0."
::= { xcvrHistPMEntry 170 }
xcvrHistPMJABRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMJABRValue object
to 0."
::= { xcvrHistPMEntry 171 }
xcvrHistPMOTUEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOTUEBValue
object to 0."
::= { xcvrHistPMEntry 172 }
xcvrHistPMOTUBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOTUBBEValue
object to 0."
::= { xcvrHistPMEntry 173 }
xcvrHistPMOTUESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOTUESValue
object to 0."
::= { xcvrHistPMEntry 174 }
xcvrHistPMOTUSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOTUSESValue
object to 0."
::= { xcvrHistPMEntry 175 }
xcvrHistPMOTUOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOTUOFSValue
object to 0."
::= { xcvrHistPMEntry 176 }
xcvrHistPMUASSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the section layer.
This object applies only to transciever ports provisioned for
a SONET OC-N protocol."
::= { xcvrHistPMEntry 177 }
xcvrHistPMUASSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer unavailable
seconds value."
::= { xcvrHistPMEntry 178 }
xcvrHistPMUASSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer
unavailable seconds value."
::= { xcvrHistPMEntry 179 }
xcvrHistPMUASSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMUASSValue
object to 0."
::= { xcvrHistPMEntry 180 }
xcvrHistPMRSUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section unavailable seconds.
This object applies only to transciever ports provisioned for
a SDH STM-N protocol."
::= { xcvrHistPMEntry 181 }
xcvrHistPMRSUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section
unavailable seconds value."
::= { xcvrHistPMEntry 182 }
xcvrHistPMRSUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
unavailable seconds value."
::= { xcvrHistPMEntry 183 }
xcvrHistPMRSUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMRSUASValue
object to 0."
::= { xcvrHistPMEntry 184 }
xcvrHistPMUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds. This object applies
only to transciever ports provisioned for the gigabit ethernet
protocol or a fiber channel protocol."
::= { xcvrHistPMEntry 185 }
xcvrHistPMUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the unavailable seconds
value."
::= { xcvrHistPMEntry 186 }
xcvrHistPMUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided unavailable
seconds value."
::= { xcvrHistPMEntry 187 }
xcvrHistPMUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMUASValue
object to 0."
::= { xcvrHistPMEntry 188 }
xcvrHistPMOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the OTN digital
wrapper layer."
::= { xcvrHistPMEntry 189 }
xcvrHistPMOTUUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTN digital wrapper layer
unavailable seconds value."
::= { xcvrHistPMEntry 190 }
xcvrHistPMOTUUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTN digital wrapper
layer unavailable seconds value."
::= { xcvrHistPMEntry 191 }
xcvrHistPMOTUUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOTUUASValue
object to 0."
::= { xcvrHistPMEntry 192 }
xcvrHistPMOTNBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous BER of transciever ports provisioned for the 10 gigabit
ethernet LAN with FEC protocol."
::= { xcvrHistPMEntry 193 }
xcvrHistPMOTNBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous BER."
::= { xcvrHistPMEntry 194 }
xcvrHistPMOTNBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous BER."
::= { xcvrHistPMEntry 195 }
xcvrHistPMOTNBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOTNBERValue
object to 0."
::= { xcvrHistPMEntry 196 }
xcvrHistPMOTNAVGBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The interval/average BER of transciever ports provisioned for the 10 gigabit
ethernet LAN with FEC protocol."
::= { xcvrHistPMEntry 197 }
xcvrHistPMOTNAVGBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the interval/average BER."
::= { xcvrHistPMEntry 198 }
xcvrHistPMOTNAVGBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided interval/average BER."
::= { xcvrHistPMEntry 199 }
xcvrHistPMOTNAVGBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOTNAVGBERValue
object to 0."
::= { xcvrHistPMEntry 200 }
xcvrHistPMNBITCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bits corrected. This object
applies only to transciever ports provisioned for a protocol
that includes Forward Error Correction (FEC)."
::= { xcvrHistPMEntry 201 }
xcvrHistPMNBITCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bits
corrected value."
::= { xcvrHistPMEntry 202 }
xcvrHistPMNBITCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number
of bits corrected value."
::= { xcvrHistPMEntry 203 }
xcvrHistPMNBITCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMNBITCR64BitValue
object to 0."
::= { xcvrHistPMEntry 204 }
xcvrHistPMNBYTCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bytes corrected. This object
applies only to transciever ports provisioned for a protocol
that includes Forward Error Correction (FEC)."
::= { xcvrHistPMEntry 205 }
xcvrHistPMNBYTCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bytes
corrected value."
::= { xcvrHistPMEntry 206 }
xcvrHistPMNBYTCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bytes
corrected value."
::= { xcvrHistPMEntry 207 }
xcvrHistPMNBYTCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMNBYTCR64BitValue
object to 0."
::= { xcvrHistPMEntry 208 }
xcvrHistPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { xcvrHistPMEntry 209 }
xcvrHistPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { xcvrHistPMEntry 210 }
xcvrHistPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { xcvrHistPMEntry 211 }
xcvrHistPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOPRMinValue
object to 0."
::= { xcvrHistPMEntry 212 }
xcvrHistPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { xcvrHistPMEntry 213 }
xcvrHistPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { xcvrHistPMEntry 214 }
xcvrHistPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { xcvrHistPMEntry 215 }
xcvrHistPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOPRMaxValue
object to 0."
::= { xcvrHistPMEntry 216 }
xcvrHistPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { xcvrHistPMEntry 217 }
xcvrHistPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { xcvrHistPMEntry 218 }
xcvrHistPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { xcvrHistPMEntry 219 }
xcvrHistPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOPRAvgValue
object to 0."
::= { xcvrHistPMEntry 220 }
xcvrHistPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { xcvrHistPMEntry 221 }
xcvrHistPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { xcvrHistPMEntry 222 }
xcvrHistPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { xcvrHistPMEntry 223 }
xcvrHistPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOPTMinValue
object to 0."
::= { xcvrHistPMEntry 224 }
xcvrHistPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { xcvrHistPMEntry 225 }
xcvrHistPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { xcvrHistPMEntry 226 }
xcvrHistPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { xcvrHistPMEntry 227 }
xcvrHistPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOPTMaxValue
object to 0."
::= { xcvrHistPMEntry 228 }
xcvrHistPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { xcvrHistPMEntry 229 }
xcvrHistPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { xcvrHistPMEntry 230 }
xcvrHistPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { xcvrHistPMEntry 231 }
xcvrHistPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the xcvrHistPMOPTAvgValue
object to 0."
::= { xcvrHistPMEntry 232 }
-----------------------------------------------------------------------
-- Objects used to manage Optical Transceiver Performance
-- Monitoring Threshold Levels
--
-- A listing of transceiver PM threshold levels are contained in the
-- xcvrPMThresholdTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each optical transceiver, providing the
-- PM threshold settings for that transceiver for a given interval type.
--
-- The following table lists the objects in each entry of the
-- xcvrPMThresholdTable.
-----------------------------------------------------------------------
xcvrPMThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF XcvrPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of threshold levels for performance monitoring counter
values on optical transceiver facilities, that are used in the
generation of threshold crossing alerts."
::= { performance 5 }
xcvrPMThresholdEntry OBJECT-TYPE
SYNTAX XcvrPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the optical transceiver performance
monitoring threshold table. Each row of this table contains a
set of PM thresholds for a given interval type that applies to
an individual optical transceiver."
INDEX { xcvrPMThresholdTypeIdx,
xcvrPMThresholdShelfIdx,
xcvrPMThresholdSlotIdx,
xcvrPMThresholdIdx,
xcvrPMThresholdIntervalTypeIdx }
::= { xcvrPMThresholdTable 1 }
XcvrPMThresholdEntry ::= SEQUENCE { xcvrPMThresholdTypeIdx XcvrType,
xcvrPMThresholdShelfIdx INTEGER,
xcvrPMThresholdSlotIdx INTEGER,
xcvrPMThresholdIdx INTEGER,
xcvrPMThresholdIntervalTypeIdx PMIntervalType,
xcvrPMThresholdCVSValue Unsigned32,
xcvrPMThresholdESSValue Unsigned32,
xcvrPMThresholdSESSValue Unsigned32,
xcvrPMThresholdSEFSSValue Unsigned32,
xcvrPMThresholdRSEBValue Unsigned32,
xcvrPMThresholdRSBBEValue Unsigned32,
xcvrPMThresholdRSESValue Unsigned32,
xcvrPMThresholdRSSESValue Unsigned32,
xcvrPMThresholdRSOFSValue Unsigned32,
xcvrPMThresholdCVValue Unsigned32,
xcvrPMThresholdESValue Unsigned32,
xcvrPMThresholdSESValue Unsigned32,
xcvrPMThresholdINVBLKValue Unsigned32,
xcvrPMThresholdUNCRCDWValue Unsigned32,
xcvrPMThresholdFCSEValue Unsigned32,
xcvrPMThresholdFRDRValue Unsigned32,
xcvrPMThresholdUSIZEValue Unsigned32,
xcvrPMThresholdOSIZEValue Unsigned32,
xcvrPMThresholdFRGTValue Unsigned32,
xcvrPMThresholdJABRValue Unsigned32,
xcvrPMThresholdOTUEBValue Unsigned32,
xcvrPMThresholdOTUBBEValue Unsigned32,
xcvrPMThresholdOTUESValue Unsigned32,
xcvrPMThresholdOTUSESValue Unsigned32,
xcvrPMThresholdOTUOFSValue Unsigned32,
xcvrPMThresholdUASSValue Unsigned32,
xcvrPMThresholdRSUASValue Unsigned32,
xcvrPMThresholdUASValue Unsigned32,
xcvrPMThresholdOTUUASValue Unsigned32 }
xcvrPMThresholdTypeIdx OBJECT-TYPE
SYNTAX XcvrType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the optical transceiver targeted for PM
thresholds."
::= { xcvrPMThresholdEntry 1 }
xcvrPMThresholdShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The shelf number on which the optical transceiver targeted for
PM thresholds is provisioned."
::= { xcvrPMThresholdEntry 2 }
xcvrPMThresholdSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The slot number on which the optical transceiver targeted for
PM thresholds is provisioned."
::= { xcvrPMThresholdEntry 3 }
xcvrPMThresholdIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The optical transceiver port number on the circuit pack that
is targeted for PM thresholds."
::= { xcvrPMThresholdEntry 4 }
xcvrPMThresholdIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length. Thresholds
are supported for the 15-minute and 1-day PM bins only."
::= { xcvrPMThresholdEntry 5 }
xcvrPMThresholdCVSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of coding violations at the
section layer. This object applies only to transciever ports
provisioned for a SONET OC-N protocol."
::= { xcvrPMThresholdEntry 6 }
xcvrPMThresholdESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored seconds at the section
layer. This object applies only to transciever ports
provisioned for a SONET OC-N protocol."
::= { xcvrPMThresholdEntry 7 }
xcvrPMThresholdSESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold fro the count of severely errored seconds at the
section layer. This object applies only to transciever ports
provisioned for a SONET OC-N protocol."
::= { xcvrPMThresholdEntry 8 }
xcvrPMThresholdSEFSSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of severely errored framing
seconds at the section layer. This object applies only to
transciever ports provisioned for a SONET OC-N protocol."
::= { xcvrPMThresholdEntry 9 }
xcvrPMThresholdRSEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section errored
blocks. This object applies only to transciever ports
provisioned for a SDH STM-N protocol."
::= { xcvrPMThresholdEntry 10 }
xcvrPMThresholdRSBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section background
block errors. This object applies only to transciever ports
provisioned for a SDH STM-N protocol."
::= { xcvrPMThresholdEntry 11 }
xcvrPMThresholdRSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section errored
seconds. This object applies only to transciever ports
provisioned for a SDH STM-N protocol."
::= { xcvrPMThresholdEntry 12 }
xcvrPMThresholdRSSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section severely
errored seconds. This object applies only to transciever ports
provisioned for a SDH STM-N protocol."
::= { xcvrPMThresholdEntry 13 }
xcvrPMThresholdRSOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section
out-of-frame seconds. This object applies only to transciever
ports provisioned for a SDH STM-N protocol."
::= { xcvrPMThresholdEntry 14 }
xcvrPMThresholdCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of coding violations. This object
applies only to transciever ports provisioned for the gigabit
ethernet protocol or a fiber channel protocol."
::= { xcvrPMThresholdEntry 15 }
xcvrPMThresholdESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored seconds. This object
applies only to transciever ports provisioned for an
ethernet protocol or a fiber channel protocol."
::= { xcvrPMThresholdEntry 16 }
xcvrPMThresholdSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of severely errored seconds. This
object applies only to transciever ports provisioned for an
ethernet protocol or a fiber channel protocol."
::= { xcvrPMThresholdEntry 17 }
xcvrPMThresholdINVBLKValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of invalid blocks. This object
applies only to transciever ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrPMThresholdEntry 18 }
xcvrPMThresholdUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of uncorrectable codewords. This
object applies only to transciever ports provisioned for the
10 gigabit ethernet LAN with FEC protocol."
::= { xcvrPMThresholdEntry 21 }
xcvrPMThresholdFCSEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of FCSE packets. This object
applies only to transceiver ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrPMThresholdEntry 22 }
xcvrPMThresholdFRDRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of dropped frames. This object
applies only to transceiver ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrPMThresholdEntry 23 }
xcvrPMThresholdUSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of undersized frames. This object
applies only to transceiver ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrPMThresholdEntry 24 }
xcvrPMThresholdOSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of oversized frames. This object
applies only to transceiver ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrPMThresholdEntry 25 }
xcvrPMThresholdFRGTValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of frame fragments. This object
applies only to transceiver ports provisioned for the 10
gigabit ethernet LAN protocol."
::= { xcvrPMThresholdEntry 26 }
xcvrPMThresholdJABRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of jabbers. This object applies
only to transceiver ports provisioned for the 10 gigabit
ethernet LAN protocol."
::= { xcvrPMThresholdEntry 27 }
xcvrPMThresholdOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored blocks at the OTN
digital wrapper layer."
::= { xcvrPMThresholdEntry 28 }
xcvrPMThresholdOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of background block errors at the
OTN digital wrapper layer."
::= { xcvrPMThresholdEntry 29 }
xcvrPMThresholdOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored seconds at the OTN
digital wrapper layer."
::= { xcvrPMThresholdEntry 30 }
xcvrPMThresholdOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of severely errored seconds at the
OTN digital wrapper layer."
::= { xcvrPMThresholdEntry 31 }
xcvrPMThresholdOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Out-of-Frame seconds at the OTN
digital wrapper layer."
::= { xcvrPMThresholdEntry 32 }
xcvrPMThresholdUASSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of unavailable seconds at the
section layer. This object applies only to transciever ports
provisioned for a SONET OC-N protocol."
::= { xcvrPMThresholdEntry 33 }
xcvrPMThresholdRSUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section
unavailable seconds. This object applies only to transciever
ports provisioned for a SDH STM-N protocol."
::= { xcvrPMThresholdEntry 34 }
xcvrPMThresholdUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of unavailable seconds. This
object applies only to transciever ports provisioned for an
ethernet protocol or a fiber channel protocol."
::= { xcvrPMThresholdEntry 35 }
xcvrPMThresholdOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of unavailable seconds at the
OTN digital wrapper layer."
::= { xcvrPMThresholdEntry 36 }
-----------------------------------------------------------------------
-- Objects used to retrieve current Active Multiplexer-
-- Demultiplexer Performance Monitoring statistics
--
-- A listing of current active multiplexer-demultiplexer PM values is
-- contained in the amdCrntPMTable of the BTI 7000 Series MIB. When
-- retrieved, this table provides one row for each set of current active
-- multiplexer-demultiplexer PM data.
--
-- The following table lists the objects in each entry of the
-- amdCrntPMTable.
-----------------------------------------------------------------------
amdCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF AmdCrntPMEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "A table of current performance monitoring statistics collected
for the ports of active multiplexer-demultiplexer circuit
packs."
::= { performance 6 }
amdCrntPMEntry OBJECT-TYPE
SYNTAX AmdCrntPMEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The row entry object of the active multiplexer-demultiplexer
current performance monitoring table. Each row of this table
contains a full set of PM statistics and related data for a
current measurement interval for a given AMD port."
INDEX { amdCrntPMTypeIdx,
amdCrntPMShelfIdx,
amdCrntPMSlotIdx,
amdCrntPMLineIdx,
amdCrntPMPortIdx,
amdCrntPMIntervalTypeIdx }
::= { amdCrntPMTable 1 }
AmdCrntPMEntry ::= SEQUENCE { amdCrntPMTypeIdx AmdType,
amdCrntPMShelfIdx INTEGER,
amdCrntPMSlotIdx INTEGER,
amdCrntPMLineIdx INTEGER,
amdCrntPMPortIdx AmdPortType,
amdCrntPMIntervalTypeIdx PMIntervalType,
amdCrntPMOPRValue FixedX10,
amdCrntPMOPRTimeStamp DateAndTime,
amdCrntPMOPRValidity PMValidity,
amdCrntPMOPTValue FixedX10,
amdCrntPMOPTTimeStamp DateAndTime,
amdCrntPMOPTValidity PMValidity,
amdCrntPMVOAValue FixedX10,
amdCrntPMVOATimeStamp DateAndTime,
amdCrntPMVOAValidity PMValidity,
amdCrntPMLitChnValue INTEGER,
amdCrntPMLitChnTimeStamp DateAndTime,
amdCrntPMLitChnValidity PMValidity }
amdCrntPMTypeIdx OBJECT-TYPE
SYNTAX AmdType
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The specific type of active multiplexer-demultiplexer circuit
pack on which the facility targeted for PMs is provisioned."
::= { amdCrntPMEntry 1 }
amdCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The number of the shelf on which the active
multiplexer-demultiplexer facility targeted for PMs is
provisioned."
::= { amdCrntPMEntry 2 }
amdCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The number of the slot within which the active
multiplexer-demultiplexer facility targeted for PMs is
provisioned."
::= { amdCrntPMEntry 3 }
amdCrntPMLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..1)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The number of the multiplexed wavelength line on the AMD
circuit pack that is targeted for PMs."
::= { amdCrntPMEntry 4 }
amdCrntPMPortIdx OBJECT-TYPE
SYNTAX AmdPortType
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "Identifies a specific port on the identified line of the AMD
circuit pack that is targeted for PMs."
::= { amdCrntPMEntry 5 }
amdCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The type of PM bin according to interval length."
::= { amdCrntPMEntry 6 }
amdCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The optical power received on the input of the AMD port."
::= { amdCrntPMEntry 7 }
amdCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The date and time stamp of the optical power received value."
::= { amdCrntPMEntry 8 }
amdCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { amdCrntPMEntry 9 }
amdCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The optical power transmitted at the output of the AMD port."
::= { amdCrntPMEntry 10 }
amdCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { amdCrntPMEntry 11 }
amdCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { amdCrntPMEntry 12 }
amdCrntPMVOAValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The variable optical attenuation of the AMD port."
::= { amdCrntPMEntry 13 }
amdCrntPMVOATimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The date and time stamp of the variable optical attenuation
value."
::= { amdCrntPMEntry 14 }
amdCrntPMVOAValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates the validity of the provided variable optical
attenuation value."
::= { amdCrntPMEntry 15 }
amdCrntPMLitChnValue OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The number of muxed channels with light on the line port."
::= { amdCrntPMEntry 16 }
amdCrntPMLitChnTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The date and time stamp of the number of lit channels value."
::= { amdCrntPMEntry 17 }
amdCrntPMLitChnValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates the validity of the provided number of lit channels
value."
::= { amdCrntPMEntry 18 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical Active Multiplexer-
-- Demultiplexer Performance Monitoring statistics
--
-- A listing of historical active multiplexer-demultiplexer PM values is
-- contained in the amdHistPMTable of the BTI 7000 Series MIB. When
-- retrieved, this table provides one row for each set of historical
-- active multiplexer-demultiplexer PM data.
--
-- The following table lists the objects in each entry of the
-- amdHistPMTable.
-----------------------------------------------------------------------
amdHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF AmdHistPMEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "A table of historical performance monitoring statistics
collected for the ports of active multiplexer-demultiplexer
circuit packs."
::= { performance 7 }
amdHistPMEntry OBJECT-TYPE
SYNTAX AmdHistPMEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The row entry object of the active multiplexer-demultiplexer
historical performance monitoring table. Each row of this
table contains a full set of PM statistics and related data
for a historical measurement interval for a given AMD port."
INDEX { amdHistPMTypeIdx,
amdHistPMShelfIdx,
amdHistPMSlotIdx,
amdHistPMLineIdx,
amdHistPMPortIdx,
amdHistPMIntervalTypeIdx,
amdHistPMIntervalIdx }
::= { amdHistPMTable 1 }
AmdHistPMEntry ::= SEQUENCE { amdHistPMTypeIdx AmdType,
amdHistPMShelfIdx INTEGER,
amdHistPMSlotIdx INTEGER,
amdHistPMLineIdx INTEGER,
amdHistPMPortIdx AmdPortType,
amdHistPMIntervalTypeIdx PMIntervalType,
amdHistPMIntervalIdx INTEGER,
amdHistPMOPRValue FixedX10,
amdHistPMOPRTimeStamp DateAndTime,
amdHistPMOPRValidity PMValidity,
amdHistPMOPTValue FixedX10,
amdHistPMOPTTimeStamp DateAndTime,
amdHistPMOPTValidity PMValidity,
amdHistPMVOAValue FixedX10,
amdHistPMVOATimeStamp DateAndTime,
amdHistPMVOAValidity PMValidity,
amdHistPMLitChnValue INTEGER,
amdHistPMLitChnTimeStamp DateAndTime,
amdHistPMLitChnValidity PMValidity }
amdHistPMTypeIdx OBJECT-TYPE
SYNTAX AmdType
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The specific type of active multiplexer-demultiplexer circuit
pack on which the facility targeted for PMs is provisioned."
::= { amdHistPMEntry 1 }
amdHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The number of the shelf on which the active
multiplexer-demultiplexer facility targeted for PMs is
provisioned."
::= { amdHistPMEntry 2 }
amdHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The number of the slot within which the active
multiplexer-demultiplexer facility targeted for PMs is
provisioned."
::= { amdHistPMEntry 3 }
amdHistPMLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..1)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The number of the multiplexed wavelength line on the AMD
circuit pack that is targeted for PMs."
::= { amdHistPMEntry 4 }
amdHistPMPortIdx OBJECT-TYPE
SYNTAX AmdPortType
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "Identifies a specific port on the identified line of the AMD
circuit pack that is targeted for PMs."
::= { amdHistPMEntry 5 }
amdHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The type of PM bin according to interval length."
::= { amdHistPMEntry 6 }
amdHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { amdHistPMEntry 7 }
amdHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The optical power received on the input of the AMD port."
::= { amdHistPMEntry 8 }
amdHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The date and time stamp of the optical power received value."
::= { amdHistPMEntry 9 }
amdHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { amdHistPMEntry 10 }
amdHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The optical power transmitted at the output of the AMD port."
::= { amdHistPMEntry 11 }
amdHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { amdHistPMEntry 12 }
amdHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { amdHistPMEntry 13 }
amdHistPMVOAValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dB/10"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The variable optical attenuation of the AMD port."
::= { amdHistPMEntry 14 }
amdHistPMVOATimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The date and time stamp of the variable optical attenuation
value."
::= { amdHistPMEntry 15 }
amdHistPMVOAValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates the validity of the provided variable optical
attenuation valcue."
::= { amdHistPMEntry 16 }
amdHistPMLitChnValue OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The number of muxed channels with light on the line port."
::= { amdHistPMEntry 17 }
amdHistPMLitChnTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The date and time stamp of the number of lit channels value."
::= { amdHistPMEntry 18 }
amdHistPMLitChnValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates the validity of the provided number of lit channels
value."
::= { amdHistPMEntry 19 }
-----------------------------------------------------------------------
-- Objects used to retrieve current SONET OC-N
-- Performance Monitoring statistics
--
-- A listing of current SONET OC-N PM values is contained in the
-- ocnCrntPMTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each set of current SONET OC-N PM data.
--
-- The following table lists the objects in each entry of the
-- ocnCrntPMTable.
-----------------------------------------------------------------------
ocnCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcnCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the SONET OC-N facilities on the NE."
::= { performance 8 }
ocnCrntPMEntry OBJECT-TYPE
SYNTAX OcnCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SONET OC-N current performance
monitoring table. Each row of this table contains a full set
of PM statistics and related data for a current measurement
interval for a given OC-N facility."
INDEX { ocnCrntPMTypeIdx,
ocnCrntPMShelfIdx,
ocnCrntPMSlotIdx,
ocnCrntPMPortIdx,
ocnCrntPMIntervalTypeIdx }
::= { ocnCrntPMTable 1 }
OcnCrntPMEntry ::= SEQUENCE { ocnCrntPMTypeIdx OcnType,
ocnCrntPMShelfIdx INTEGER,
ocnCrntPMSlotIdx INTEGER,
ocnCrntPMPortIdx INTEGER,
ocnCrntPMIntervalTypeIdx PMIntervalType,
ocnCrntPMOPRValue FixedX10,
ocnCrntPMOPRTimeStamp DateAndTime,
ocnCrntPMOPRValidity PMValidity,
ocnCrntPMOPTValue FixedX10,
ocnCrntPMOPTTimeStamp DateAndTime,
ocnCrntPMOPTValidity PMValidity,
ocnCrntPMTempValue INTEGER,
ocnCrntPMTempTimeStamp DateAndTime,
ocnCrntPMTempValidity PMValidity,
ocnCrntPMSupplyVoltageValue FixedX10,
ocnCrntPMSupplyVoltageTimeStamp DateAndTime,
ocnCrntPMSupplyVoltageValidity PMValidity,
ocnCrntPMLBCValue INTEGER,
ocnCrntPMLBCTimeStamp DateAndTime,
ocnCrntPMLBCValidity PMValidity,
ocnCrntPMCVSValue Unsigned32,
ocnCrntPMCVSTimeStamp DateAndTime,
ocnCrntPMCVSValidity PMValidity,
ocnCrntPMESSValue Unsigned32,
ocnCrntPMESSTimeStamp DateAndTime,
ocnCrntPMESSValidity PMValidity,
ocnCrntPMSESSValue Unsigned32,
ocnCrntPMSESSTimeStamp DateAndTime,
ocnCrntPMSESSValidity PMValidity,
ocnCrntPMSEFSSValue Unsigned32,
ocnCrntPMSEFSSTimeStamp DateAndTime,
ocnCrntPMSEFSSValidity PMValidity,
ocnCrntPMSupplyVoltage2Value FixedX10,
ocnCrntPMSupplyVoltage2TimeStamp DateAndTime,
ocnCrntPMSupplyVoltage2Validity PMValidity,
ocnCrntPMCVLValue Unsigned32,
ocnCrntPMCVLTimeStamp DateAndTime,
ocnCrntPMCVLValidity PMValidity,
ocnCrntPMESLValue Unsigned32,
ocnCrntPMESLTimeStamp DateAndTime,
ocnCrntPMESLValidity PMValidity,
ocnCrntPMSESLValue Unsigned32,
ocnCrntPMSESLTimeStamp DateAndTime,
ocnCrntPMSESLValidity PMValidity,
ocnCrntPMUASLValue Unsigned32,
ocnCrntPMUASLTimeStamp DateAndTime,
ocnCrntPMUASLValidity PMValidity,
ocnCrntPMOTUEBValue Unsigned32,
ocnCrntPMOTUEBTimeStamp DateAndTime,
ocnCrntPMOTUEBValidity PMValidity,
ocnCrntPMOTUBBEValue Unsigned32,
ocnCrntPMOTUBBETimeStamp DateAndTime,
ocnCrntPMOTUBBEValidity PMValidity,
ocnCrntPMOTUESValue Unsigned32,
ocnCrntPMOTUESTimeStamp DateAndTime,
ocnCrntPMOTUESValidity PMValidity,
ocnCrntPMOTUSESValue Unsigned32,
ocnCrntPMOTUSESTimeStamp DateAndTime,
ocnCrntPMOTUSESValidity PMValidity,
ocnCrntPMOTUOFSValue Unsigned32,
ocnCrntPMOTUOFSTimeStamp DateAndTime,
ocnCrntPMOTUOFSValidity PMValidity,
ocnCrntPMNBITCRValue Unsigned32,
ocnCrntPMNBITCRTimeStamp DateAndTime,
ocnCrntPMNBITCRValidity PMValidity,
ocnCrntPMNBYTCRValue Unsigned32,
ocnCrntPMNBYTCRTimeStamp DateAndTime,
ocnCrntPMNBYTCRValidity PMValidity,
ocnCrntPMUNCRCDWValue Unsigned32,
ocnCrntPMUNCRCDWTimeStamp DateAndTime,
ocnCrntPMUNCRCDWValidity PMValidity,
ocnCrntPMCVSInitialize InitializeCmd,
ocnCrntPMESSInitialize InitializeCmd,
ocnCrntPMSESSInitialize InitializeCmd,
ocnCrntPMSEFSSInitialize InitializeCmd,
ocnCrntPMCVLInitialize InitializeCmd,
ocnCrntPMESLInitialize InitializeCmd,
ocnCrntPMSESLInitialize InitializeCmd,
ocnCrntPMUASLInitialize InitializeCmd,
ocnCrntPMOTUEBInitialize InitializeCmd,
ocnCrntPMOTUBBEInitialize InitializeCmd,
ocnCrntPMOTUESInitialize InitializeCmd,
ocnCrntPMOTUSESInitialize InitializeCmd,
ocnCrntPMOTUOFSInitialize InitializeCmd,
ocnCrntPMNBITCRInitialize InitializeCmd,
ocnCrntPMNBYTCRInitialize InitializeCmd,
ocnCrntPMUNCRCDWInitialize InitializeCmd,
ocnCrntPMOTNBERValue DisplayString,
ocnCrntPMOTNBERTimeStamp DateAndTime,
ocnCrntPMOTNBERValidity PMValidity,
ocnCrntPMOTNBERInitialize InitializeCmd,
ocnCrntPMOTNAVGBERValue DisplayString,
ocnCrntPMOTNAVGBERTimeStamp DateAndTime,
ocnCrntPMOTNAVGBERValidity PMValidity,
ocnCrntPMOTNAVGBERInitialize InitializeCmd,
ocnCrntPMNBITCR64BitValue Unsigned64,
ocnCrntPMNBITCR64BitTimeStamp DateAndTime,
ocnCrntPMNBITCR64BitValidity PMValidity,
ocnCrntPMNBITCR64BitInitialize InitializeCmd,
ocnCrntPMNBYTCR64BitValue Unsigned64,
ocnCrntPMNBYTCR64BitTimeStamp DateAndTime,
ocnCrntPMNBYTCR64BitValidity PMValidity,
ocnCrntPMNBYTCR64BitInitialize InitializeCmd,
ocnCrntPMUASSValue Unsigned32,
ocnCrntPMUASSTimeStamp DateAndTime,
ocnCrntPMUASSValidity PMValidity,
ocnCrntPMUASSInitialize InitializeCmd,
ocnCrntPMOTUUASValue Unsigned32,
ocnCrntPMOTUUASTimeStamp DateAndTime,
ocnCrntPMOTUUASValidity PMValidity,
ocnCrntPMOTUUASInitialize InitializeCmd,
ocnCrntPMOPRMinValue FixedX10,
ocnCrntPMOPRMinTimeStamp DateAndTime,
ocnCrntPMOPRMinValidity PMValidity,
ocnCrntPMOPRMinInitialize InitializeCmd,
ocnCrntPMOPRMaxValue FixedX10,
ocnCrntPMOPRMaxTimeStamp DateAndTime,
ocnCrntPMOPRMaxValidity PMValidity,
ocnCrntPMOPRMaxInitialize InitializeCmd,
ocnCrntPMOPRAvgValue FixedX10,
ocnCrntPMOPRAvgTimeStamp DateAndTime,
ocnCrntPMOPRAvgValidity PMValidity,
ocnCrntPMOPRAvgInitialize InitializeCmd,
ocnCrntPMOPTMinValue FixedX10,
ocnCrntPMOPTMinTimeStamp DateAndTime,
ocnCrntPMOPTMinValidity PMValidity,
ocnCrntPMOPTMinInitialize InitializeCmd,
ocnCrntPMOPTMaxValue FixedX10,
ocnCrntPMOPTMaxTimeStamp DateAndTime,
ocnCrntPMOPTMaxValidity PMValidity,
ocnCrntPMOPTMaxInitialize InitializeCmd,
ocnCrntPMOPTAvgValue FixedX10,
ocnCrntPMOPTAvgTimeStamp DateAndTime,
ocnCrntPMOPTAvgValidity PMValidity,
ocnCrntPMOPTAvgInitialize InitializeCmd }
ocnCrntPMTypeIdx OBJECT-TYPE
SYNTAX OcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of OC-N facility targeted for PMs."
::= { ocnCrntPMEntry 1 }
ocnCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the OC-N facility targeted
for PMs is provisioned."
::= { ocnCrntPMEntry 2 }
ocnCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the OC-N facility targeted
for PMs is provisioned."
::= { ocnCrntPMEntry 3 }
ocnCrntPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the OC-N
facility targeted for PMs is provisioned."
::= { ocnCrntPMEntry 4 }
ocnCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { ocnCrntPMEntry 5 }
ocnCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the OC-N facility
port."
::= { ocnCrntPMEntry 6 }
ocnCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { ocnCrntPMEntry 7 }
ocnCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { ocnCrntPMEntry 8 }
ocnCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the OC-N
facility port."
::= { ocnCrntPMEntry 9 }
ocnCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { ocnCrntPMEntry 10 }
ocnCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { ocnCrntPMEntry 11 }
ocnCrntPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the OC-N facility port."
::= { ocnCrntPMEntry 12 }
ocnCrntPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { ocnCrntPMEntry 13 }
ocnCrntPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { ocnCrntPMEntry 14 }
ocnCrntPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the OC-N facility port."
::= { ocnCrntPMEntry 15 }
ocnCrntPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { ocnCrntPMEntry 16 }
ocnCrntPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { ocnCrntPMEntry 17 }
ocnCrntPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the OC-N facility port."
::= { ocnCrntPMEntry 18 }
ocnCrntPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { ocnCrntPMEntry 19 }
ocnCrntPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { ocnCrntPMEntry 20 }
ocnCrntPMCVSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations at the section layer."
::= { ocnCrntPMEntry 21 }
ocnCrntPMCVSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer coding violations
value."
::= { ocnCrntPMEntry 22 }
ocnCrntPMCVSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer coding
violations value."
::= { ocnCrntPMEntry 23 }
ocnCrntPMESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the section layer."
::= { ocnCrntPMEntry 24 }
ocnCrntPMESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer errored seconds
value."
::= { ocnCrntPMEntry 25 }
ocnCrntPMESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer errored
seconds value."
::= { ocnCrntPMEntry 26 }
ocnCrntPMSESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the section layer."
::= { ocnCrntPMEntry 27 }
ocnCrntPMSESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
seconds value."
::= { ocnCrntPMEntry 28 }
ocnCrntPMSESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored seconds value."
::= { ocnCrntPMEntry 29 }
ocnCrntPMSEFSSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored framing seconds at the section
layer."
::= { ocnCrntPMEntry 30 }
ocnCrntPMSEFSSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
framing seconds value."
::= { ocnCrntPMEntry 31 }
ocnCrntPMSEFSSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored framing seconds value."
::= { ocnCrntPMEntry 32 }
ocnCrntPMSupplyVoltage2Value OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the second supply voltage source measured on the
OC-N facility port transceiver."
::= { ocnCrntPMEntry 33 }
ocnCrntPMSupplyVoltage2TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the second supply voltage value."
::= { ocnCrntPMEntry 34 }
ocnCrntPMSupplyVoltage2Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided second supply voltage
value."
::= { ocnCrntPMEntry 35 }
ocnCrntPMCVLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations at the line layer."
::= { ocnCrntPMEntry 36 }
ocnCrntPMCVLTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the line layer coding violations
value."
::= { ocnCrntPMEntry 37 }
ocnCrntPMCVLValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided line layer coding
violations value."
::= { ocnCrntPMEntry 38 }
ocnCrntPMESLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the line layer."
::= { ocnCrntPMEntry 39 }
ocnCrntPMESLTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the line layer errored seconds
value."
::= { ocnCrntPMEntry 40 }
ocnCrntPMESLValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided line layer errored
seconds value."
::= { ocnCrntPMEntry 41 }
ocnCrntPMSESLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the line layer."
::= { ocnCrntPMEntry 42 }
ocnCrntPMSESLTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the line layer severely errored
seconds value."
::= { ocnCrntPMEntry 43 }
ocnCrntPMSESLValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided line layer severely
errored seconds value."
::= { ocnCrntPMEntry 44 }
ocnCrntPMUASLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the line layer."
::= { ocnCrntPMEntry 45 }
ocnCrntPMUASLTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the line layer unavailable seconds
value."
::= { ocnCrntPMEntry 46 }
ocnCrntPMUASLValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided line layer unavailable
seconds value."
::= { ocnCrntPMEntry 47 }
ocnCrntPMOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored blocks."
::= { ocnCrntPMEntry 48 }
ocnCrntPMOTUEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored blocks value."
::= { ocnCrntPMEntry 49 }
ocnCrntPMOTUEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored blocks value."
::= { ocnCrntPMEntry 50 }
ocnCrntPMOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer background block
errors."
::= { ocnCrntPMEntry 51 }
ocnCrntPMOTUBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
background block errors value."
::= { ocnCrntPMEntry 52 }
ocnCrntPMOTUBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer background block errors value."
::= { ocnCrntPMEntry 53 }
ocnCrntPMOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored seconds."
::= { ocnCrntPMEntry 54 }
ocnCrntPMOTUESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored seconds value."
::= { ocnCrntPMEntry 55 }
ocnCrntPMOTUESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored seconds value."
::= { ocnCrntPMEntry 56 }
ocnCrntPMOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer severely errored
seconds."
::= { ocnCrntPMEntry 57 }
ocnCrntPMOTUSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
severely errored seconds value."
::= { ocnCrntPMEntry 58 }
ocnCrntPMOTUSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer severely errored seconds value."
::= { ocnCrntPMEntry 59 }
ocnCrntPMOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer out-of-frame seconds."
::= { ocnCrntPMEntry 60 }
ocnCrntPMOTUOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
out-of-frame seconds value."
::= { ocnCrntPMEntry 61 }
ocnCrntPMOTUOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer out-of-frame seconds value."
::= { ocnCrntPMEntry 62 }
ocnCrntPMNBITCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bits corrected. This object applies
only to OC-192 line port provisioned for OTN line mapping."
::= { ocnCrntPMEntry 63 }
ocnCrntPMNBITCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bits corrected
value."
::= { ocnCrntPMEntry 64 }
ocnCrntPMNBITCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bits
corrected value."
::= { ocnCrntPMEntry 65 }
ocnCrntPMNBYTCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bytes corrected. This object
applies only to OC-192 line port provisioned for OTN line
mapping."
::= { ocnCrntPMEntry 66 }
ocnCrntPMNBYTCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bytes corrected
value."
::= { ocnCrntPMEntry 67 }
ocnCrntPMNBYTCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bytes
corrected value."
::= { ocnCrntPMEntry 68 }
ocnCrntPMUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of uncorrectable codewords. This object applies only
to OC-192 line port provisioned for OTN line mapping."
::= { ocnCrntPMEntry 69 }
ocnCrntPMUNCRCDWTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the uncorrectable codewords value."
::= { ocnCrntPMEntry 70 }
ocnCrntPMUNCRCDWValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided uncorrectable codewords
value."
::= { ocnCrntPMEntry 71 }
ocnCrntPMCVSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMCVSValue object
to 0."
::= { ocnCrntPMEntry 72 }
ocnCrntPMESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMESSValue object
to 0."
::= { ocnCrntPMEntry 73 }
ocnCrntPMSESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMSESSValue object
to 0."
::= { ocnCrntPMEntry 74 }
ocnCrntPMSEFSSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMSEFSSValue object
to 0."
::= { ocnCrntPMEntry 75 }
ocnCrntPMCVLInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMCVLValue object
to 0."
::= { ocnCrntPMEntry 76 }
ocnCrntPMESLInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMESLValue object
to 0."
::= { ocnCrntPMEntry 77 }
ocnCrntPMSESLInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMSESLValue object
to 0."
::= { ocnCrntPMEntry 78 }
ocnCrntPMUASLInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMUASLValue object
to 0."
::= { ocnCrntPMEntry 79 }
ocnCrntPMOTUEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOTUEBValue object
to 0."
::= { ocnCrntPMEntry 80 }
ocnCrntPMOTUBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOTUBBEValue
object to 0."
::= { ocnCrntPMEntry 81 }
ocnCrntPMOTUESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOTUESValue object
to 0."
::= { ocnCrntPMEntry 82 }
ocnCrntPMOTUSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOTUSESValue
object to 0."
::= { ocnCrntPMEntry 83 }
ocnCrntPMOTUOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOTUOFSValue
object to 0."
::= { ocnCrntPMEntry 84 }
ocnCrntPMNBITCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMNBITCRValue
object to 0."
::= { ocnCrntPMEntry 85 }
ocnCrntPMNBYTCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMNBYTCRValue
object to 0."
::= { ocnCrntPMEntry 86 }
ocnCrntPMUNCRCDWInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMUNCRCDWValue
object to 0."
::= { ocnCrntPMEntry 87 }
ocnCrntPMOTNBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous BER of OC-192 line port provisioned for OTN line mapping."
::= { ocnCrntPMEntry 88 }
ocnCrntPMOTNBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous BER."
::= { ocnCrntPMEntry 89 }
ocnCrntPMOTNBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous BER."
::= { ocnCrntPMEntry 90 }
ocnCrntPMOTNBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOTNBERValue
object to 0."
::= { ocnCrntPMEntry 91 }
ocnCrntPMOTNAVGBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The interval/average BER of OC-192 line port provisioned for OTN line mapping."
::= { ocnCrntPMEntry 92 }
ocnCrntPMOTNAVGBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the interval/average BER."
::= { ocnCrntPMEntry 93 }
ocnCrntPMOTNAVGBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided interval/average BER."
::= { ocnCrntPMEntry 94 }
ocnCrntPMOTNAVGBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOTNAVGBERValue
object to 0."
::= { ocnCrntPMEntry 95 }
ocnCrntPMNBITCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bits corrected. This object
applies only to OC-192 line port provisioned for OTN line mapping."
::= { ocnCrntPMEntry 96 }
ocnCrntPMNBITCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bits corrected
value."
::= { ocnCrntPMEntry 97 }
ocnCrntPMNBITCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bits
corrected value."
::= { ocnCrntPMEntry 98 }
ocnCrntPMNBITCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMNBITCR64BitValue
object to 0."
::= { ocnCrntPMEntry 99 }
ocnCrntPMNBYTCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bytes corrected. This object
applies only to OC-192 line port provisioned for OTN line
mapping."
::= { ocnCrntPMEntry 100 }
ocnCrntPMNBYTCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bytes corrected
value."
::= { ocnCrntPMEntry 101 }
ocnCrntPMNBYTCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bytes
corrected value."
::= { ocnCrntPMEntry 102 }
ocnCrntPMNBYTCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMNBYTCR64BitValue
object to 0."
::= { ocnCrntPMEntry 103 }
ocnCrntPMUASSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the section layer.
This object applies only to OC-192 line port provisioned
for OTN line mapping."
::= { ocnCrntPMEntry 104 }
ocnCrntPMUASSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the unavailable seconds at
the section layer"
::= { ocnCrntPMEntry 105 }
ocnCrntPMUASSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the unavailable seconds at
the section layer."
::= { ocnCrntPMEntry 106 }
ocnCrntPMUASSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMUASSValue
object to 0."
::= { ocnCrntPMEntry 107 }
ocnCrntPMOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer unavailable seconds."
::= { ocnCrntPMEntry 108 }
ocnCrntPMOTUUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
unavailable seconds value."
::= { ocnCrntPMEntry 109 }
ocnCrntPMOTUUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer unavailable seconds value."
::= { ocnCrntPMEntry 110 }
ocnCrntPMOTUUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOTUUASValue
object to 0."
::= { ocnCrntPMEntry 111 }
ocnCrntPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { ocnCrntPMEntry 112 }
ocnCrntPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { ocnCrntPMEntry 113 }
ocnCrntPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { ocnCrntPMEntry 114 }
ocnCrntPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOPRMinValue
object to 0."
::= { ocnCrntPMEntry 115 }
ocnCrntPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { ocnCrntPMEntry 116 }
ocnCrntPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { ocnCrntPMEntry 117 }
ocnCrntPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { ocnCrntPMEntry 118 }
ocnCrntPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOPRMaxValue
object to 0."
::= { ocnCrntPMEntry 119 }
ocnCrntPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { ocnCrntPMEntry 120 }
ocnCrntPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { ocnCrntPMEntry 121 }
ocnCrntPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { ocnCrntPMEntry 122 }
ocnCrntPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOPRAvgValue
object to 0."
::= { ocnCrntPMEntry 123 }
ocnCrntPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { ocnCrntPMEntry 124 }
ocnCrntPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { ocnCrntPMEntry 125 }
ocnCrntPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { ocnCrntPMEntry 126 }
ocnCrntPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOPTMinValue
object to 0."
::= { ocnCrntPMEntry 127 }
ocnCrntPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { ocnCrntPMEntry 128 }
ocnCrntPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { ocnCrntPMEntry 129 }
ocnCrntPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { ocnCrntPMEntry 130 }
ocnCrntPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOPTMaxValue
object to 0."
::= { ocnCrntPMEntry 131 }
ocnCrntPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { ocnCrntPMEntry 132 }
ocnCrntPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { ocnCrntPMEntry 133 }
ocnCrntPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { ocnCrntPMEntry 134 }
ocnCrntPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnCrntPMOPTAvgValue
object to 0."
::= { ocnCrntPMEntry 135 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical SONET OC-N
-- Performance Monitoring statistics
--
-- A listing of historical SONET OC-N PM values is contained in the
-- ocnHistPMTable of the BTI 7000 Series MIB. When retrieved, this table
-- provides one row for each set of current SONET OC-N PM data.
--
-- The following table lists the objects in each entry of the
-- ocnHistPMTable.
-----------------------------------------------------------------------
ocnHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcnHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the SONET OC-N facilities on the NE."
::= { performance 9 }
ocnHistPMEntry OBJECT-TYPE
SYNTAX OcnHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SONET OC-N historical performance
monitoring table. Each row of this table contains a full set
of PM statistics and related data for a historical measurement
interval for a given OC-N facility."
INDEX { ocnHistPMTypeIdx,
ocnHistPMShelfIdx,
ocnHistPMSlotIdx,
ocnHistPMPortIdx,
ocnHistPMIntervalTypeIdx,
ocnHistPMIntervalIdx }
::= { ocnHistPMTable 1 }
OcnHistPMEntry ::= SEQUENCE { ocnHistPMTypeIdx OcnType,
ocnHistPMShelfIdx INTEGER,
ocnHistPMSlotIdx INTEGER,
ocnHistPMPortIdx INTEGER,
ocnHistPMIntervalTypeIdx PMIntervalType,
ocnHistPMIntervalIdx INTEGER,
ocnHistPMOPRValue FixedX10,
ocnHistPMOPRTimeStamp DateAndTime,
ocnHistPMOPRValidity PMValidity,
ocnHistPMOPTValue FixedX10,
ocnHistPMOPTTimeStamp DateAndTime,
ocnHistPMOPTValidity PMValidity,
ocnHistPMTempValue INTEGER,
ocnHistPMTempTimeStamp DateAndTime,
ocnHistPMTempValidity PMValidity,
ocnHistPMSupplyVoltageValue FixedX10,
ocnHistPMSupplyVoltageTimeStamp DateAndTime,
ocnHistPMSupplyVoltageValidity PMValidity,
ocnHistPMLBCValue INTEGER,
ocnHistPMLBCTimeStamp DateAndTime,
ocnHistPMLBCValidity PMValidity,
ocnHistPMCVSValue Unsigned32,
ocnHistPMCVSTimeStamp DateAndTime,
ocnHistPMCVSValidity PMValidity,
ocnHistPMESSValue Unsigned32,
ocnHistPMESSTimeStamp DateAndTime,
ocnHistPMESSValidity PMValidity,
ocnHistPMSESSValue Unsigned32,
ocnHistPMSESSTimeStamp DateAndTime,
ocnHistPMSESSValidity PMValidity,
ocnHistPMSEFSSValue Unsigned32,
ocnHistPMSEFSSTimeStamp DateAndTime,
ocnHistPMSEFSSValidity PMValidity,
ocnHistPMSupplyVoltage2Value FixedX10,
ocnHistPMSupplyVoltage2TimeStamp DateAndTime,
ocnHistPMSupplyVoltage2Validity PMValidity,
ocnHistPMCVLValue Unsigned32,
ocnHistPMCVLTimeStamp DateAndTime,
ocnHistPMCVLValidity PMValidity,
ocnHistPMESLValue Unsigned32,
ocnHistPMESLTimeStamp DateAndTime,
ocnHistPMESLValidity PMValidity,
ocnHistPMSESLValue Unsigned32,
ocnHistPMSESLTimeStamp DateAndTime,
ocnHistPMSESLValidity PMValidity,
ocnHistPMUASLValue Unsigned32,
ocnHistPMUASLTimeStamp DateAndTime,
ocnHistPMUASLValidity PMValidity,
ocnHistPMOTUEBValue Unsigned32,
ocnHistPMOTUEBTimeStamp DateAndTime,
ocnHistPMOTUEBValidity PMValidity,
ocnHistPMOTUBBEValue Unsigned32,
ocnHistPMOTUBBETimeStamp DateAndTime,
ocnHistPMOTUBBEValidity PMValidity,
ocnHistPMOTUESValue Unsigned32,
ocnHistPMOTUESTimeStamp DateAndTime,
ocnHistPMOTUESValidity PMValidity,
ocnHistPMOTUSESValue Unsigned32,
ocnHistPMOTUSESTimeStamp DateAndTime,
ocnHistPMOTUSESValidity PMValidity,
ocnHistPMOTUOFSValue Unsigned32,
ocnHistPMOTUOFSTimeStamp DateAndTime,
ocnHistPMOTUOFSValidity PMValidity,
ocnHistPMNBITCRValue Unsigned32,
ocnHistPMNBITCRTimeStamp DateAndTime,
ocnHistPMNBITCRValidity PMValidity,
ocnHistPMNBYTCRValue Unsigned32,
ocnHistPMNBYTCRTimeStamp DateAndTime,
ocnHistPMNBYTCRValidity PMValidity,
ocnHistPMUNCRCDWValue Unsigned32,
ocnHistPMUNCRCDWTimeStamp DateAndTime,
ocnHistPMUNCRCDWValidity PMValidity,
ocnHistPMCVSInitialize InitializeCmd,
ocnHistPMESSInitialize InitializeCmd,
ocnHistPMSESSInitialize InitializeCmd,
ocnHistPMSEFSSInitialize InitializeCmd,
ocnHistPMCVLInitialize InitializeCmd,
ocnHistPMESLInitialize InitializeCmd,
ocnHistPMSESLInitialize InitializeCmd,
ocnHistPMUASLInitialize InitializeCmd,
ocnHistPMOTUEBInitialize InitializeCmd,
ocnHistPMOTUBBEInitialize InitializeCmd,
ocnHistPMOTUESInitialize InitializeCmd,
ocnHistPMOTUSESInitialize InitializeCmd,
ocnHistPMOTUOFSInitialize InitializeCmd,
ocnHistPMNBITCRInitialize InitializeCmd,
ocnHistPMNBYTCRInitialize InitializeCmd,
ocnHistPMUNCRCDWInitialize InitializeCmd,
ocnHistPMOTNBERValue DisplayString,
ocnHistPMOTNBERTimeStamp DateAndTime,
ocnHistPMOTNBERValidity PMValidity,
ocnHistPMOTNBERInitialize InitializeCmd,
ocnHistPMOTNAVGBERValue DisplayString,
ocnHistPMOTNAVGBERTimeStamp DateAndTime,
ocnHistPMOTNAVGBERValidity PMValidity,
ocnHistPMOTNAVGBERInitialize InitializeCmd,
ocnHistPMNBITCR64BitValue Unsigned64,
ocnHistPMNBITCR64BitTimeStamp DateAndTime,
ocnHistPMNBITCR64BitValidity PMValidity,
ocnHistPMNBITCR64BitInitialize InitializeCmd,
ocnHistPMNBYTCR64BitValue Unsigned64,
ocnHistPMNBYTCR64BitTimeStamp DateAndTime,
ocnHistPMNBYTCR64BitValidity PMValidity,
ocnHistPMNBYTCR64BitInitialize InitializeCmd,
ocnHistPMUASSValue Unsigned32,
ocnHistPMUASSTimeStamp DateAndTime,
ocnHistPMUASSValidity PMValidity,
ocnHistPMUASSInitialize InitializeCmd,
ocnHistPMOTUUASValue Unsigned32,
ocnHistPMOTUUASTimeStamp DateAndTime,
ocnHistPMOTUUASValidity PMValidity,
ocnHistPMOTUUASInitialize InitializeCmd,
ocnHistPMOPRMinValue FixedX10,
ocnHistPMOPRMinTimeStamp DateAndTime,
ocnHistPMOPRMinValidity PMValidity,
ocnHistPMOPRMinInitialize InitializeCmd,
ocnHistPMOPRMaxValue FixedX10,
ocnHistPMOPRMaxTimeStamp DateAndTime,
ocnHistPMOPRMaxValidity PMValidity,
ocnHistPMOPRMaxInitialize InitializeCmd,
ocnHistPMOPRAvgValue FixedX10,
ocnHistPMOPRAvgTimeStamp DateAndTime,
ocnHistPMOPRAvgValidity PMValidity,
ocnHistPMOPRAvgInitialize InitializeCmd,
ocnHistPMOPTMinValue FixedX10,
ocnHistPMOPTMinTimeStamp DateAndTime,
ocnHistPMOPTMinValidity PMValidity,
ocnHistPMOPTMinInitialize InitializeCmd,
ocnHistPMOPTMaxValue FixedX10,
ocnHistPMOPTMaxTimeStamp DateAndTime,
ocnHistPMOPTMaxValidity PMValidity,
ocnHistPMOPTMaxInitialize InitializeCmd,
ocnHistPMOPTAvgValue FixedX10,
ocnHistPMOPTAvgTimeStamp DateAndTime,
ocnHistPMOPTAvgValidity PMValidity,
ocnHistPMOPTAvgInitialize InitializeCmd}
ocnHistPMTypeIdx OBJECT-TYPE
SYNTAX OcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the OC-N facility targeted for PMs."
::= { ocnHistPMEntry 1 }
ocnHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the OC-N facility targeted
for PMs is provisioned."
::= { ocnHistPMEntry 2 }
ocnHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the OC-N facility targeted
for PMs is provisioned."
::= { ocnHistPMEntry 3 }
ocnHistPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the OC-N
facility targeted for PMs is provisioned."
::= { ocnHistPMEntry 4 }
ocnHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { ocnHistPMEntry 5 }
ocnHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { ocnHistPMEntry 6 }
ocnHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the OC-N facility."
::= { ocnHistPMEntry 7 }
ocnHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { ocnHistPMEntry 8 }
ocnHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { ocnHistPMEntry 9 }
ocnHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the OC-N
facility."
::= { ocnHistPMEntry 10 }
ocnHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { ocnHistPMEntry 11 }
ocnHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { ocnHistPMEntry 12 }
ocnHistPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the OC-N facility port."
::= { ocnHistPMEntry 13 }
ocnHistPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { ocnHistPMEntry 14 }
ocnHistPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { ocnHistPMEntry 15 }
ocnHistPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the OC-N facility port."
::= { ocnHistPMEntry 16 }
ocnHistPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { ocnHistPMEntry 17 }
ocnHistPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { ocnHistPMEntry 18 }
ocnHistPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the OC-N facility port."
::= { ocnHistPMEntry 19 }
ocnHistPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { ocnHistPMEntry 20 }
ocnHistPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { ocnHistPMEntry 21 }
ocnHistPMCVSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations at the section layer."
::= { ocnHistPMEntry 22 }
ocnHistPMCVSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer coding violations
value."
::= { ocnHistPMEntry 23 }
ocnHistPMCVSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer coding
violations value."
::= { ocnHistPMEntry 24 }
ocnHistPMESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the section layer."
::= { ocnHistPMEntry 25 }
ocnHistPMESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer errored seconds
value."
::= { ocnHistPMEntry 26 }
ocnHistPMESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer errored
seconds value."
::= { ocnHistPMEntry 27 }
ocnHistPMSESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the section layer."
::= { ocnHistPMEntry 28 }
ocnHistPMSESSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
seconds value."
::= { ocnHistPMEntry 29 }
ocnHistPMSESSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored seconds value."
::= { ocnHistPMEntry 30 }
ocnHistPMSEFSSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored framing seconds at the section
layer."
::= { ocnHistPMEntry 31 }
ocnHistPMSEFSSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the section layer severely errored
framing seconds value."
::= { ocnHistPMEntry 32 }
ocnHistPMSEFSSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided section layer severely
errored framing seconds value."
::= { ocnHistPMEntry 33 }
ocnHistPMSupplyVoltage2Value OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the second supply voltage source measured on the
OC-N facility port transceiver."
::= { ocnHistPMEntry 34 }
ocnHistPMSupplyVoltage2TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the second supply voltage value."
::= { ocnHistPMEntry 35 }
ocnHistPMSupplyVoltage2Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided second supply voltage
value."
::= { ocnHistPMEntry 36 }
ocnHistPMCVLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations at the line layer."
::= { ocnHistPMEntry 37 }
ocnHistPMCVLTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the line layer coding violations
value."
::= { ocnHistPMEntry 38 }
ocnHistPMCVLValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided line layer coding
violations value."
::= { ocnHistPMEntry 39 }
ocnHistPMESLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the line layer."
::= { ocnHistPMEntry 40 }
ocnHistPMESLTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the line layer errored seconds
value."
::= { ocnHistPMEntry 41 }
ocnHistPMESLValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided line layer errored
seconds value."
::= { ocnHistPMEntry 42 }
ocnHistPMSESLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the line layer."
::= { ocnHistPMEntry 43 }
ocnHistPMSESLTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the line layer severely errored
seconds value."
::= { ocnHistPMEntry 44 }
ocnHistPMSESLValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided line layer severely
errored seconds value."
::= { ocnHistPMEntry 45 }
ocnHistPMUASLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the line layer."
::= { ocnHistPMEntry 46 }
ocnHistPMUASLTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the line layer unavailable seconds
value."
::= { ocnHistPMEntry 47 }
ocnHistPMUASLValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided line layer unavailable
seconds value."
::= { ocnHistPMEntry 48 }
ocnHistPMOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored blocks."
::= { ocnHistPMEntry 49 }
ocnHistPMOTUEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored blocks value."
::= { ocnHistPMEntry 50 }
ocnHistPMOTUEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored blocks value."
::= { ocnHistPMEntry 51 }
ocnHistPMOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer background block
errors."
::= { ocnHistPMEntry 52 }
ocnHistPMOTUBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
background block errors value."
::= { ocnHistPMEntry 53 }
ocnHistPMOTUBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer background block errors value."
::= { ocnHistPMEntry 54 }
ocnHistPMOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored seconds."
::= { ocnHistPMEntry 55 }
ocnHistPMOTUESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored seconds value."
::= { ocnHistPMEntry 56 }
ocnHistPMOTUESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored seconds value."
::= { ocnHistPMEntry 57 }
ocnHistPMOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer severely errored
seconds."
::= { ocnHistPMEntry 58 }
ocnHistPMOTUSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
severely errored seconds value."
::= { ocnHistPMEntry 59 }
ocnHistPMOTUSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer severely errored seconds value."
::= { ocnHistPMEntry 60 }
ocnHistPMOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer out-of-frame seconds."
::= { ocnHistPMEntry 61 }
ocnHistPMOTUOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
out-of-frame seconds value."
::= { ocnHistPMEntry 62 }
ocnHistPMOTUOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer out-of-frame seconds value."
::= { ocnHistPMEntry 63 }
ocnHistPMNBITCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bits corrected. This object applies
only to OC-192 line port provisioned for OTN line mapping."
::= { ocnHistPMEntry 64 }
ocnHistPMNBITCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bits corrected
value."
::= { ocnHistPMEntry 65 }
ocnHistPMNBITCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bits
corrected value."
::= { ocnHistPMEntry 66 }
ocnHistPMNBYTCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bytes corrected. This object
applies only to OC-192 line port provisioned for OTN line
mapping."
::= { ocnHistPMEntry 67 }
ocnHistPMNBYTCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bytes corrected
value."
::= { ocnHistPMEntry 68 }
ocnHistPMNBYTCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bytes
corrected value."
::= { ocnHistPMEntry 69 }
ocnHistPMUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of uncorrectable codewords. This object applies only
to OC-192 line port provisioned for OTN line mapping."
::= { ocnHistPMEntry 70 }
ocnHistPMUNCRCDWTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the uncorrectable codewords value."
::= { ocnHistPMEntry 71 }
ocnHistPMUNCRCDWValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided uncorrectable codewords
value."
::= { ocnHistPMEntry 72 }
ocnHistPMCVSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMCVSValue object
to 0."
::= { ocnHistPMEntry 73 }
ocnHistPMESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMESSValue object
to 0."
::= { ocnHistPMEntry 74 }
ocnHistPMSESSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMSESSValue object
to 0."
::= { ocnHistPMEntry 75 }
ocnHistPMSEFSSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMSEFSSValue object
to 0."
::= { ocnHistPMEntry 76 }
ocnHistPMCVLInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMCVLValue object
to 0."
::= { ocnHistPMEntry 77 }
ocnHistPMESLInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMESLValue object
to 0."
::= { ocnHistPMEntry 78 }
ocnHistPMSESLInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMSESLValue object
to 0."
::= { ocnHistPMEntry 79 }
ocnHistPMUASLInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMUASLValue object
to 0."
::= { ocnHistPMEntry 80 }
ocnHistPMOTUEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOTUEBValue object
to 0."
::= { ocnHistPMEntry 81 }
ocnHistPMOTUBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOTUBBEValue
object to 0."
::= { ocnHistPMEntry 82 }
ocnHistPMOTUESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOTUESValue object
to 0."
::= { ocnHistPMEntry 83 }
ocnHistPMOTUSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOTUSESValue
object to 0."
::= { ocnHistPMEntry 84 }
ocnHistPMOTUOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOTUOFSValue
object to 0."
::= { ocnHistPMEntry 85 }
ocnHistPMNBITCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMNBITCRValue
object to 0."
::= { ocnHistPMEntry 86 }
ocnHistPMNBYTCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMNBYTCRValue
object to 0."
::= { ocnHistPMEntry 87 }
ocnHistPMUNCRCDWInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMUNCRCDWValue
object to 0."
::= { ocnHistPMEntry 88 }
ocnHistPMOTNBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous BER of OC-192 line port provisioned for OTN line mapping."
::= { ocnHistPMEntry 89 }
ocnHistPMOTNBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous BER."
::= { ocnHistPMEntry 90 }
ocnHistPMOTNBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous BER."
::= { ocnHistPMEntry 91 }
ocnHistPMOTNBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOTNBERValue
object to 0."
::= { ocnHistPMEntry 92 }
ocnHistPMOTNAVGBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The interval/average BER of OC-192 line port provisioned for OTN line mapping."
::= { ocnHistPMEntry 93 }
ocnHistPMOTNAVGBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the interval/average BER."
::= { ocnHistPMEntry 94 }
ocnHistPMOTNAVGBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided interval/average BER."
::= { ocnHistPMEntry 95 }
ocnHistPMOTNAVGBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOTNAVGBERValue
object to 0."
::= { ocnHistPMEntry 96 }
ocnHistPMNBITCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bits corrected. This object
applies only to OC-192 line port provisioned for OTN line mapping."
::= { ocnHistPMEntry 97 }
ocnHistPMNBITCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bits corrected
value."
::= { ocnHistPMEntry 98 }
ocnHistPMNBITCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bits
corrected value."
::= { ocnHistPMEntry 99 }
ocnHistPMNBITCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMNBITCR64BitValue
object to 0."
::= { ocnHistPMEntry 100 }
ocnHistPMNBYTCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bytes corrected. This object
applies only to OC-192 line port provisioned for OTN line
mapping."
::= { ocnHistPMEntry 101 }
ocnHistPMNBYTCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bytes corrected
value."
::= { ocnHistPMEntry 102 }
ocnHistPMNBYTCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bytes
corrected value."
::= { ocnHistPMEntry 103 }
ocnHistPMNBYTCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMNBYTCR64BitValue
object to 0."
::= { ocnHistPMEntry 104 }
ocnHistPMUASSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the section layer.
This object applies only to OC-192 line port provisioned
for OTN line mapping."
::= { ocnHistPMEntry 105 }
ocnHistPMUASSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the unavailable seconds at the section layer."
::= { ocnHistPMEntry 106 }
ocnHistPMUASSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the unavailable seconds at the section layer."
::= { ocnHistPMEntry 107 }
ocnHistPMUASSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMUASSValue
object to 0."
::= { ocnHistPMEntry 108 }
ocnHistPMOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer unavailable seconds."
::= { ocnHistPMEntry 109 }
ocnHistPMOTUUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
unavailable seconds value."
::= { ocnHistPMEntry 110 }
ocnHistPMOTUUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer unavailable seconds value."
::= { ocnHistPMEntry 111 }
ocnHistPMOTUUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOTUUASValue
object to 0."
::= { ocnHistPMEntry 112 }
ocnHistPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { ocnHistPMEntry 113 }
ocnHistPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { ocnHistPMEntry 114 }
ocnHistPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { ocnHistPMEntry 115 }
ocnHistPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOPRMinValue
object to 0."
::= { ocnHistPMEntry 116 }
ocnHistPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { ocnHistPMEntry 117 }
ocnHistPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { ocnHistPMEntry 118 }
ocnHistPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { ocnHistPMEntry 119 }
ocnHistPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOPRMaxValue
object to 0."
::= { ocnHistPMEntry 120 }
ocnHistPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { ocnHistPMEntry 121 }
ocnHistPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { ocnHistPMEntry 122 }
ocnHistPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { ocnHistPMEntry 123 }
ocnHistPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOPRAvgValue
object to 0."
::= { ocnHistPMEntry 124 }
ocnHistPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { ocnHistPMEntry 125 }
ocnHistPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { ocnHistPMEntry 126 }
ocnHistPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { ocnHistPMEntry 127 }
ocnHistPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOPTMinValue
object to 0."
::= { ocnHistPMEntry 128 }
ocnHistPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { ocnHistPMEntry 129 }
ocnHistPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { ocnHistPMEntry 130 }
ocnHistPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { ocnHistPMEntry 131 }
ocnHistPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOPTMaxValue
object to 0."
::= { ocnHistPMEntry 132 }
ocnHistPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { ocnHistPMEntry 133 }
ocnHistPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { ocnHistPMEntry 134 }
ocnHistPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { ocnHistPMEntry 135 }
ocnHistPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ocnHistPMOPTAvgValue
object to 0."
::= { ocnHistPMEntry 136 }
-----------------------------------------------------------------------
-- Objects used to manage SONET OC-N Performance
-- Monitoring Threshold Levels
--
-- A listing of SONET OC-N PM threshold levels is contained in the
-- ocnPMThresholdTable of the BTI-7000-MIB. When retrieved, this table
-- provides one row for each set of current SONET OC-N PM threshold
-- data.
--
-- The following table lists the objects in each entry of the
-- ocnPMThresholdTable.
-----------------------------------------------------------------------
ocnPMThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcnPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of threshold levels for performance monitoring counter
values on SONET OC-N facilities, that are used in the
generation of threshold crossing alerts."
::= { performance 10 }
ocnPMThresholdEntry OBJECT-TYPE
SYNTAX OcnPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SONET OC-N performance monitoring
threshold table. Each row of this table contains a set of PM
thresholds for a given interval type that applies to an
individual OC-N facility."
INDEX { ocnPMThresholdTypeIdx,
ocnPMThresholdShelfIdx,
ocnPMThresholdSlotIdx,
ocnPMThresholdPortIdx,
ocnPMThresholdIntervalTypeIdx }
::= { ocnPMThresholdTable 1 }
OcnPMThresholdEntry ::= SEQUENCE { ocnPMThresholdTypeIdx OcnType,
ocnPMThresholdShelfIdx INTEGER,
ocnPMThresholdSlotIdx INTEGER,
ocnPMThresholdPortIdx INTEGER,
ocnPMThresholdIntervalTypeIdx PMIntervalType,
ocnPMThresholdCVSValue Unsigned32,
ocnPMThresholdESSValue Unsigned32,
ocnPMThresholdSESSValue Unsigned32,
ocnPMThresholdSEFSSValue Unsigned32,
ocnPMThresholdCVLValue Unsigned32,
ocnPMThresholdESLValue Unsigned32,
ocnPMThresholdSESLValue Unsigned32,
ocnPMThresholdUASLValue Unsigned32,
ocnPMThresholdOTUEBValue Unsigned32,
ocnPMThresholdOTUBBEValue Unsigned32,
ocnPMThresholdOTUESValue Unsigned32,
ocnPMThresholdOTUSESValue Unsigned32,
ocnPMThresholdOTUOFSValue Unsigned32,
ocnPMThresholdUNCRCDWValue Unsigned32,
ocnPMThresholdUASSValue Unsigned32,
ocnPMThresholdOTUUASValue Unsigned32 }
ocnPMThresholdTypeIdx OBJECT-TYPE
SYNTAX OcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the OC-N facility targeted for PM thresholds."
::= { ocnPMThresholdEntry 1 }
ocnPMThresholdShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The shelf number on which the OC-N facility targeted for PM
thresholds is provisioned."
::= { ocnPMThresholdEntry 2 }
ocnPMThresholdSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The slot number on which the OC-N facility targeted for PM
thresholds is provisioned."
::= { ocnPMThresholdEntry 3 }
ocnPMThresholdPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the OC-N
facility targeted for PM thresholds is provisioned."
::= { ocnPMThresholdEntry 4 }
ocnPMThresholdIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length. Thresholds
are supported for the 15-minute and 1-day PM bins only."
::= { ocnPMThresholdEntry 5 }
ocnPMThresholdCVSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of coding violations at the
section layer."
::= { ocnPMThresholdEntry 6 }
ocnPMThresholdESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored seconds at the section
layer."
::= { ocnPMThresholdEntry 7 }
ocnPMThresholdSESSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold fro the count of severely errored seconds at the
section layer."
::= { ocnPMThresholdEntry 8 }
ocnPMThresholdSEFSSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of severely errored framing
seconds at the section layer."
::= { ocnPMThresholdEntry 9 }
ocnPMThresholdCVLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of coding violations at the line
layer."
::= { ocnPMThresholdEntry 10 }
ocnPMThresholdESLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored seconds at the line
layer."
::= { ocnPMThresholdEntry 11 }
ocnPMThresholdSESLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of severely errored seconds at the
line layer."
::= { ocnPMThresholdEntry 12 }
ocnPMThresholdUASLValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of unavailable seconds at the line
layer."
::= { ocnPMThresholdEntry 13 }
ocnPMThresholdOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored blocks at the OTU
digital wrapper layer."
::= { ocnPMThresholdEntry 14 }
ocnPMThresholdOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of background block errors at the
OTU digital wrapper layer."
::= { ocnPMThresholdEntry 15 }
ocnPMThresholdOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored seconds at the OTU
digital wrapper layer."
::= { ocnPMThresholdEntry 16 }
ocnPMThresholdOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of severely errored seconds at the
OTU digital wrapper layer."
::= { ocnPMThresholdEntry 17 }
ocnPMThresholdOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of out-of-frame seconds at the OTU
digital wrapper layer."
::= { ocnPMThresholdEntry 18 }
ocnPMThresholdUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of uncorrectable codewords."
::= { ocnPMThresholdEntry 21 }
ocnPMThresholdUASSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of unavailable seconds at the
section layer."
::= { ocnPMThresholdEntry 22 }
ocnPMThresholdOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of unavailable seconds at the
OTU digital wrapper layer."
::= { ocnPMThresholdEntry 23 }
-----------------------------------------------------------------------
-- Objects used to retrieve current SONET STS-N
-- Performance Monitoring statistics
--
-- A listing of current SONET STS-N PM values is contained in the
-- stsnCrntPMTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each set of current SONET STS-N PM data.
--
-- The following table lists the objects in each entry of the
-- stsnCrntPMTable.
-----------------------------------------------------------------------
stsnCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF StsnCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the SONET STS-N facilities on the NE."
::= { performance 11 }
stsnCrntPMEntry OBJECT-TYPE
SYNTAX StsnCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SONET STS-N current performance
monitoring table. Each row of this table contains a full set
of PM statistics and related data for a current measurement
interval for a given STS-N facility."
INDEX { stsnCrntPMTypeIdx,
stsnCrntPMShelfIdx,
stsnCrntPMSlotIdx,
stsnCrntPMPortIdx,
stsnCrntPMIdx,
stsnCrntPMIntervalTypeIdx }
::= { stsnCrntPMTable 1 }
StsnCrntPMEntry ::= SEQUENCE { stsnCrntPMTypeIdx StsnType,
stsnCrntPMShelfIdx INTEGER,
stsnCrntPMSlotIdx INTEGER,
stsnCrntPMPortIdx INTEGER,
stsnCrntPMIdx INTEGER,
stsnCrntPMIntervalTypeIdx PMIntervalType,
stsnCrntPMCVPValue Unsigned32,
stsnCrntPMCVPTimeStamp DateAndTime,
stsnCrntPMCVPValidity PMValidity,
stsnCrntPMESPValue Unsigned32,
stsnCrntPMESPTimeStamp DateAndTime,
stsnCrntPMESPValidity PMValidity,
stsnCrntPMSESPValue Unsigned32,
stsnCrntPMSESPTimeStamp DateAndTime,
stsnCrntPMSESPValidity PMValidity,
stsnCrntPMUASPValue Unsigned32,
stsnCrntPMUASPTimeStamp DateAndTime,
stsnCrntPMUASPValidity PMValidity,
stsnCrntPMFCPValue Unsigned32,
stsnCrntPMFCPTimeStamp DateAndTime,
stsnCrntPMFCPValidity PMValidity,
stsnCrntPMCVPInitialize InitializeCmd,
stsnCrntPMESPInitialize InitializeCmd,
stsnCrntPMSESPInitialize InitializeCmd,
stsnCrntPMUASPInitialize InitializeCmd,
stsnCrntPMFCPInitialize InitializeCmd }
stsnCrntPMTypeIdx OBJECT-TYPE
SYNTAX StsnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of STS-N facility targeted for PMs."
::= { stsnCrntPMEntry 1 }
stsnCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the STS-N facility targeted for
PMs."
::= { stsnCrntPMEntry 2 }
stsnCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the STS-N facility targeted for
PMs."
::= { stsnCrntPMEntry 3 }
stsnCrntPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack of the STS-N
facility targeted for PMs."
::= { stsnCrntPMEntry 4 }
stsnCrntPMIdx OBJECT-TYPE
SYNTAX INTEGER (1..192)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The sts index number of the STS-N facility targeted for PMs."
::= { stsnCrntPMEntry 5 }
stsnCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { stsnCrntPMEntry 6 }
stsnCrntPMCVPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations at the path layer."
::= { stsnCrntPMEntry 7 }
stsnCrntPMCVPTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the path layer coding violations
value."
::= { stsnCrntPMEntry 8 }
stsnCrntPMCVPValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided path layer coding
violations value."
::= { stsnCrntPMEntry 9 }
stsnCrntPMESPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the path layer."
::= { stsnCrntPMEntry 10 }
stsnCrntPMESPTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the path layer errored seconds
value."
::= { stsnCrntPMEntry 11 }
stsnCrntPMESPValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided path layer errored
seconds value."
::= { stsnCrntPMEntry 12 }
stsnCrntPMSESPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the path layer."
::= { stsnCrntPMEntry 13 }
stsnCrntPMSESPTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the path layer severely errored
seconds value."
::= { stsnCrntPMEntry 14 }
stsnCrntPMSESPValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided path layer severely
errored seconds value."
::= { stsnCrntPMEntry 15 }
stsnCrntPMUASPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the path layer."
::= { stsnCrntPMEntry 16 }
stsnCrntPMUASPTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the path layer unavailable seconds
value."
::= { stsnCrntPMEntry 17 }
stsnCrntPMUASPValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided path layer unavailable
seconds value."
::= { stsnCrntPMEntry 18 }
stsnCrntPMFCPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The failure count at the path layer."
::= { stsnCrntPMEntry 19 }
stsnCrntPMFCPTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the path layer failure count
value."
::= { stsnCrntPMEntry 20 }
stsnCrntPMFCPValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided path layer failure
count value."
::= { stsnCrntPMEntry 21 }
stsnCrntPMCVPInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stsnCrntPMCVPValue object
to 0."
::= { stsnCrntPMEntry 22 }
stsnCrntPMESPInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stsnCrntPMESPValue object
to 0."
::= { stsnCrntPMEntry 23 }
stsnCrntPMSESPInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stsnCrntPMSESPValue object
to 0."
::= { stsnCrntPMEntry 24 }
stsnCrntPMUASPInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stsnCrntPMUASPValue object
to 0."
::= { stsnCrntPMEntry 25 }
stsnCrntPMFCPInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stsnCrntPMFCPValue object
to 0."
::= { stsnCrntPMEntry 26 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical SONET STS-N
-- Performance Monitoring statistics
--
-- A listing of historical SONET STS-N PM values is contained in the
-- stsnHistPMTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each set of historical SONET STS-N PM
-- data.
--
-- The following table lists the objects in each entry of the
-- stsnHistPMTable.
-----------------------------------------------------------------------
stsnHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF StsnHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the SONET STS-N facilities on the NE."
::= { performance 12 }
stsnHistPMEntry OBJECT-TYPE
SYNTAX StsnHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SONET STS-N historical performance
monitoring table. Each row of this table contains a full set
of PM statistics and related data for a historical measurement
interval for a given STS-N facility."
INDEX { stsnHistPMTypeIdx,
stsnHistPMShelfIdx,
stsnHistPMSlotIdx,
stsnHistPMPortIdx,
stsnHistPMIdx,
stsnHistPMIntervalTypeIdx,
stsnHistPMIntervalIdx }
::= { stsnHistPMTable 1 }
StsnHistPMEntry ::= SEQUENCE { stsnHistPMTypeIdx StsnType,
stsnHistPMShelfIdx INTEGER,
stsnHistPMSlotIdx INTEGER,
stsnHistPMPortIdx INTEGER,
stsnHistPMIdx INTEGER,
stsnHistPMIntervalTypeIdx PMIntervalType,
stsnHistPMIntervalIdx INTEGER,
stsnHistPMCVPValue Unsigned32,
stsnHistPMCVPTimeStamp DateAndTime,
stsnHistPMCVPValidity PMValidity,
stsnHistPMESPValue Unsigned32,
stsnHistPMESPTimeStamp DateAndTime,
stsnHistPMESPValidity PMValidity,
stsnHistPMSESPValue Unsigned32,
stsnHistPMSESPTimeStamp DateAndTime,
stsnHistPMSESPValidity PMValidity,
stsnHistPMUASPValue Unsigned32,
stsnHistPMUASPTimeStamp DateAndTime,
stsnHistPMUASPValidity PMValidity,
stsnHistPMFCPValue Unsigned32,
stsnHistPMFCPTimeStamp DateAndTime,
stsnHistPMFCPValidity PMValidity,
stsnHistPMCVPInitialize InitializeCmd,
stsnHistPMESPInitialize InitializeCmd,
stsnHistPMSESPInitialize InitializeCmd,
stsnHistPMUASPInitialize InitializeCmd,
stsnHistPMFCPInitialize InitializeCmd }
stsnHistPMTypeIdx OBJECT-TYPE
SYNTAX StsnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the STS-N facility targeted for PMs."
::= { stsnHistPMEntry 1 }
stsnHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the STS-N facility targeted for
PMs."
::= { stsnHistPMEntry 2 }
stsnHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the STS-N facility targeted for
PMs."
::= { stsnHistPMEntry 3 }
stsnHistPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack of the STS-N
facility targeted for PMs."
::= { stsnHistPMEntry 4 }
stsnHistPMIdx OBJECT-TYPE
SYNTAX INTEGER (1..192)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The sts index number of the STS-N facility targeted for PMs."
::= { stsnHistPMEntry 5 }
stsnHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { stsnHistPMEntry 6 }
stsnHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { stsnHistPMEntry 7 }
stsnHistPMCVPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of coding violations at the path layer."
::= { stsnHistPMEntry 8 }
stsnHistPMCVPTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the path layer coding violations
value."
::= { stsnHistPMEntry 9 }
stsnHistPMCVPValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided path layer coding
violations value."
::= { stsnHistPMEntry 10 }
stsnHistPMESPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of errored seconds at the path layer."
::= { stsnHistPMEntry 11 }
stsnHistPMESPTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the path layer errored seconds
value."
::= { stsnHistPMEntry 12 }
stsnHistPMESPValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided path layer errored
seconds value."
::= { stsnHistPMEntry 13 }
stsnHistPMSESPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of severely errored seconds at the path layer."
::= { stsnHistPMEntry 14 }
stsnHistPMSESPTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the path layer severely errored
seconds value."
::= { stsnHistPMEntry 15 }
stsnHistPMSESPValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided path layer severely
errored seconds value."
::= { stsnHistPMEntry 16 }
stsnHistPMUASPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds at the path layer."
::= { stsnHistPMEntry 17 }
stsnHistPMUASPTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the path layer unavailable seconds
value."
::= { stsnHistPMEntry 18 }
stsnHistPMUASPValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided path layer unavailable
seconds value."
::= { stsnHistPMEntry 19 }
stsnHistPMFCPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The failure count at the path layer."
::= { stsnHistPMEntry 20 }
stsnHistPMFCPTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the path layer failure count."
::= { stsnHistPMEntry 21 }
stsnHistPMFCPValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided path layer failure
count."
::= { stsnHistPMEntry 22 }
stsnHistPMCVPInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stsnHistPMCVPValue object
to 0."
::= { stsnHistPMEntry 23 }
stsnHistPMESPInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stsnHistPMESPValue object
to 0."
::= { stsnHistPMEntry 24 }
stsnHistPMSESPInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stsnHistPMSESPValue object
to 0."
::= { stsnHistPMEntry 25 }
stsnHistPMUASPInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stsnHistPMUASPValue object
to 0."
::= { stsnHistPMEntry 26 }
stsnHistPMFCPInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stsnHistPMFCPValue object
to 0."
::= { stsnHistPMEntry 27 }
-----------------------------------------------------------------------
-- Objects used to manage SONET STS-N Performance
-- Monitoring Threshold Levels
--
-- A listing of SONET STS-N PM threshold levels is contained in the
-- stsnPMThresholdByPortTable of the BTI-7000-MIB. When retrieved, this
-- table provides one row for each set of current SONET STS-N
-- PM threshold data.
--
-- The following table lists the objects in each entry of the
-- stsnPMThresholdByPortTable.
-----------------------------------------------------------------------
stsnPMThresholdByPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF StsnPMThresholdByPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of threshold levels for performance monitoring counter
values on SONET STS-N facilities, that are used in the
generation of threshold crossing alerts. The STS-N threshold
settings will be the same for all STS channels on a given OC-N
facility port."
::= { performance 13 }
stsnPMThresholdByPortEntry OBJECT-TYPE
SYNTAX StsnPMThresholdByPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SONET STS-N performance monitoring
threshold by port table. Each row of this table contains a set
of PM thresholds for a given interval type that applies to all
the STS-N channels on an OC-N facility port."
INDEX { stsnPMThresholdByPortTypeIdx,
stsnPMThresholdByPortShelfIdx,
stsnPMThresholdByPortSlotIdx,
stsnPMThresholdByPortIdx,
stsnPMThresholdByPortIntervalTypeIdx }
::= { stsnPMThresholdByPortTable 1 }
StsnPMThresholdByPortEntry ::= SEQUENCE { stsnPMThresholdByPortTypeIdx StsnType,
stsnPMThresholdByPortShelfIdx INTEGER,
stsnPMThresholdByPortSlotIdx INTEGER,
stsnPMThresholdByPortIdx INTEGER,
stsnPMThresholdByPortIntervalTypeIdx PMIntervalType,
stsnPMThresholdByPortCVPValue Unsigned32,
stsnPMThresholdByPortESPValue Unsigned32,
stsnPMThresholdByPortSESPValue Unsigned32,
stsnPMThresholdByPortUASPValue Unsigned32,
stsnPMThresholdByPortFCPValue Unsigned32 }
stsnPMThresholdByPortTypeIdx OBJECT-TYPE
SYNTAX StsnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the STS-N facilities targeted for PM thresholds."
::= { stsnPMThresholdByPortEntry 1 }
stsnPMThresholdByPortShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The shelf number of the STS-N facilities targeted for PM
thresholds."
::= { stsnPMThresholdByPortEntry 2 }
stsnPMThresholdByPortSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The slot number of the STS-N facilities targeted for PM
thresholds."
::= { stsnPMThresholdByPortEntry 3 }
stsnPMThresholdByPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack of the STS-N
facilities targeted for PM thresholds."
::= { stsnPMThresholdByPortEntry 4 }
stsnPMThresholdByPortIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length. Thresholds
are supported for the 15-minute and 1-day PM bins only."
::= { stsnPMThresholdByPortEntry 5 }
stsnPMThresholdByPortCVPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of coding violations at the path
layer."
::= { stsnPMThresholdByPortEntry 6 }
stsnPMThresholdByPortESPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored seconds at the path
layer."
::= { stsnPMThresholdByPortEntry 9 }
stsnPMThresholdByPortSESPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of severely errored seconds at the
path layer."
::= { stsnPMThresholdByPortEntry 10 }
stsnPMThresholdByPortUASPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of unavailable seconds at the path
layer."
::= { stsnPMThresholdByPortEntry 11 }
stsnPMThresholdByPortFCPValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the failure count at the path layer."
::= { stsnPMThresholdByPortEntry 12 }
-----------------------------------------------------------------------
-- Objects used to retrieve current SDH STM-N
-- Performance Monitoring statistics
--
-- A listing of current SDH STM-N PM values is contained in the
-- StmnCrntPMEntry of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each set of current SDH STM-N PM data.
--
-- The following table lists the objects in each entry of the
-- StmnCrntPMEntry.
-----------------------------------------------------------------------
stmnCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF StmnCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the SDH STM-N facilities on the NE."
::= { performance 14 }
stmnCrntPMEntry OBJECT-TYPE
SYNTAX StmnCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SDH STM-N current performance
monitoring table. Each row of this table contains a full set
of PM statistics and related data for a current measurement
interval for a given STM-N facility."
INDEX { stmnCrntPMTypeIdx,
stmnCrntPMShelfIdx,
stmnCrntPMSlotIdx,
stmnCrntPMPortIdx,
stmnCrntPMIntervalTypeIdx }
::= { stmnCrntPMTable 1 }
StmnCrntPMEntry ::= SEQUENCE { stmnCrntPMTypeIdx StmnType,
stmnCrntPMShelfIdx INTEGER,
stmnCrntPMSlotIdx INTEGER,
stmnCrntPMPortIdx INTEGER,
stmnCrntPMIntervalTypeIdx PMIntervalType,
stmnCrntPMOPRValue FixedX10,
stmnCrntPMOPRTimeStamp DateAndTime,
stmnCrntPMOPRValidity PMValidity,
stmnCrntPMOPTValue FixedX10,
stmnCrntPMOPTTimeStamp DateAndTime,
stmnCrntPMOPTValidity PMValidity,
stmnCrntPMTempValue INTEGER,
stmnCrntPMTempTimeStamp DateAndTime,
stmnCrntPMTempValidity PMValidity,
stmnCrntPMSupplyVoltageValue FixedX10,
stmnCrntPMSupplyVoltageTimeStamp DateAndTime,
stmnCrntPMSupplyVoltageValidity PMValidity,
stmnCrntPMLBCValue INTEGER,
stmnCrntPMLBCTimeStamp DateAndTime,
stmnCrntPMLBCValidity PMValidity,
stmnCrntPMRSEBValue Unsigned32,
stmnCrntPMRSEBTimeStamp DateAndTime,
stmnCrntPMRSEBValidity PMValidity,
stmnCrntPMRSBBEValue Unsigned32,
stmnCrntPMRSBBETimeStamp DateAndTime,
stmnCrntPMRSBBEValidity PMValidity,
stmnCrntPMRSESValue Unsigned32,
stmnCrntPMRSESTimeStamp DateAndTime,
stmnCrntPMRSESValidity PMValidity,
stmnCrntPMRSSESValue Unsigned32,
stmnCrntPMRSSESTimeStamp DateAndTime,
stmnCrntPMRSSESValidity PMValidity,
stmnCrntPMRSOFSValue Unsigned32,
stmnCrntPMRSOFSTimeStamp DateAndTime,
stmnCrntPMRSOFSValidity PMValidity,
stmnCrntPMSupplyVoltage2Value FixedX10,
stmnCrntPMSupplyVoltage2TimeStamp DateAndTime,
stmnCrntPMSupplyVoltage2Validity PMValidity,
stmnCrntPMMSEBValue Unsigned32,
stmnCrntPMMSEBTimeStamp DateAndTime,
stmnCrntPMMSEBValidity PMValidity,
stmnCrntPMMSBBEValue Unsigned32,
stmnCrntPMMSBBETimeStamp DateAndTime,
stmnCrntPMMSBBEValidity PMValidity,
stmnCrntPMMSESValue Unsigned32,
stmnCrntPMMSESTimeStamp DateAndTime,
stmnCrntPMMSESValidity PMValidity,
stmnCrntPMMSSESValue Unsigned32,
stmnCrntPMMSSESTimeStamp DateAndTime,
stmnCrntPMMSSESValidity PMValidity,
stmnCrntPMMSUASValue Unsigned32,
stmnCrntPMMSUASTimeStamp DateAndTime,
stmnCrntPMMSUASValidity PMValidity,
stmnCrntPMOTUEBValue Unsigned32,
stmnCrntPMOTUEBTimeStamp DateAndTime,
stmnCrntPMOTUEBValidity PMValidity,
stmnCrntPMOTUBBEValue Unsigned32,
stmnCrntPMOTUBBETimeStamp DateAndTime,
stmnCrntPMOTUBBEValidity PMValidity,
stmnCrntPMOTUESValue Unsigned32,
stmnCrntPMOTUESTimeStamp DateAndTime,
stmnCrntPMOTUESValidity PMValidity,
stmnCrntPMOTUSESValue Unsigned32,
stmnCrntPMOTUSESTimeStamp DateAndTime,
stmnCrntPMOTUSESValidity PMValidity,
stmnCrntPMOTUOFSValue Unsigned32,
stmnCrntPMOTUOFSTimeStamp DateAndTime,
stmnCrntPMOTUOFSValidity PMValidity,
stmnCrntPMNBITCRValue Unsigned32,
stmnCrntPMNBITCRTimeStamp DateAndTime,
stmnCrntPMNBITCRValidity PMValidity,
stmnCrntPMNBYTCRValue Unsigned32,
stmnCrntPMNBYTCRTimeStamp DateAndTime,
stmnCrntPMNBYTCRValidity PMValidity,
stmnCrntPMUNCRCDWValue Unsigned32,
stmnCrntPMUNCRCDWTimeStamp DateAndTime,
stmnCrntPMUNCRCDWValidity PMValidity,
stmnCrntPMRSEBInitialize InitializeCmd,
stmnCrntPMRSBBEInitialize InitializeCmd,
stmnCrntPMRSESInitialize InitializeCmd,
stmnCrntPMRSSESInitialize InitializeCmd,
stmnCrntPMRSOFSInitialize InitializeCmd,
stmnCrntPMMSEBInitialize InitializeCmd,
stmnCrntPMMSBBEInitialize InitializeCmd,
stmnCrntPMMSESInitialize InitializeCmd,
stmnCrntPMMSSESInitialize InitializeCmd,
stmnCrntPMMSUASInitialize InitializeCmd,
stmnCrntPMOTUEBInitialize InitializeCmd,
stmnCrntPMOTUBBEInitialize InitializeCmd,
stmnCrntPMOTUESInitialize InitializeCmd,
stmnCrntPMOTUSESInitialize InitializeCmd,
stmnCrntPMOTUOFSInitialize InitializeCmd,
stmnCrntPMNBITCRInitialize InitializeCmd,
stmnCrntPMNBYTCRInitialize InitializeCmd,
stmnCrntPMUNCRCDWInitialize InitializeCmd,
stmnCrntPMOTNBERValue DisplayString,
stmnCrntPMOTNBERTimeStamp DateAndTime,
stmnCrntPMOTNBERValidity PMValidity,
stmnCrntPMOTNBERInitialize InitializeCmd,
stmnCrntPMOTNAVGBERValue DisplayString,
stmnCrntPMOTNAVGBERTimeStamp DateAndTime,
stmnCrntPMOTNAVGBERValidity PMValidity,
stmnCrntPMOTNAVGBERInitialize InitializeCmd,
stmnCrntPMNBITCR64BitValue Unsigned64,
stmnCrntPMNBITCR64BitTimeStamp DateAndTime,
stmnCrntPMNBITCR64BitValidity PMValidity,
stmnCrntPMNBITCR64BitInitialize InitializeCmd,
stmnCrntPMNBYTCR64BitValue Unsigned64,
stmnCrntPMNBYTCR64BitTimeStamp DateAndTime,
stmnCrntPMNBYTCR64BitValidity PMValidity,
stmnCrntPMNBYTCR64BitInitialize InitializeCmd,
stmnCrntPMRSUASValue Unsigned32,
stmnCrntPMRSUASTimeStamp DateAndTime,
stmnCrntPMRSUASValidity PMValidity,
stmnCrntPMRSUASInitialize InitializeCmd,
stmnCrntPMOTUUASValue Unsigned32,
stmnCrntPMOTUUASTimeStamp DateAndTime,
stmnCrntPMOTUUASValidity PMValidity,
stmnCrntPMOTUUASInitialize InitializeCmd,
stmnCrntPMOPRMinValue FixedX10,
stmnCrntPMOPRMinTimeStamp DateAndTime,
stmnCrntPMOPRMinValidity PMValidity,
stmnCrntPMOPRMinInitialize InitializeCmd,
stmnCrntPMOPRMaxValue FixedX10,
stmnCrntPMOPRMaxTimeStamp DateAndTime,
stmnCrntPMOPRMaxValidity PMValidity,
stmnCrntPMOPRMaxInitialize InitializeCmd,
stmnCrntPMOPRAvgValue FixedX10,
stmnCrntPMOPRAvgTimeStamp DateAndTime,
stmnCrntPMOPRAvgValidity PMValidity,
stmnCrntPMOPRAvgInitialize InitializeCmd,
stmnCrntPMOPTMinValue FixedX10,
stmnCrntPMOPTMinTimeStamp DateAndTime,
stmnCrntPMOPTMinValidity PMValidity,
stmnCrntPMOPTMinInitialize InitializeCmd,
stmnCrntPMOPTMaxValue FixedX10,
stmnCrntPMOPTMaxTimeStamp DateAndTime,
stmnCrntPMOPTMaxValidity PMValidity,
stmnCrntPMOPTMaxInitialize InitializeCmd,
stmnCrntPMOPTAvgValue FixedX10,
stmnCrntPMOPTAvgTimeStamp DateAndTime,
stmnCrntPMOPTAvgValidity PMValidity,
stmnCrntPMOPTAvgInitialize InitializeCmd }
stmnCrntPMTypeIdx OBJECT-TYPE
SYNTAX StmnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of STM-N facility targeted for PMs."
::= { stmnCrntPMEntry 1 }
stmnCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the STM-N facility targeted
for PMs is provisioned."
::= { stmnCrntPMEntry 2 }
stmnCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the STM-N facility
targeted for PMs is provisioned."
::= { stmnCrntPMEntry 3 }
stmnCrntPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the STM-N
facility targeted for PMs is provisioned."
::= { stmnCrntPMEntry 4 }
stmnCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { stmnCrntPMEntry 5 }
stmnCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the OC-N facility
port."
::= { stmnCrntPMEntry 6 }
stmnCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { stmnCrntPMEntry 7 }
stmnCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { stmnCrntPMEntry 8 }
stmnCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the STM-N
facility port."
::= { stmnCrntPMEntry 9 }
stmnCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { stmnCrntPMEntry 10 }
stmnCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { stmnCrntPMEntry 11 }
stmnCrntPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the STM-N facility port."
::= { stmnCrntPMEntry 12 }
stmnCrntPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { stmnCrntPMEntry 13 }
stmnCrntPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { stmnCrntPMEntry 14 }
stmnCrntPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the STM-N facility port."
::= { stmnCrntPMEntry 15 }
stmnCrntPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { stmnCrntPMEntry 16 }
stmnCrntPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { stmnCrntPMEntry 17 }
stmnCrntPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the STM-N facility port."
::= { stmnCrntPMEntry 18 }
stmnCrntPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { stmnCrntPMEntry 19 }
stmnCrntPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { stmnCrntPMEntry 20 }
stmnCrntPMRSEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section errored blocks."
::= { stmnCrntPMEntry 21 }
stmnCrntPMRSEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section errored
blocks value."
::= { stmnCrntPMEntry 22 }
stmnCrntPMRSEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
errored blocks value."
::= { stmnCrntPMEntry 23 }
stmnCrntPMRSBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section background block errors."
::= { stmnCrntPMEntry 24 }
stmnCrntPMRSBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section background
block errors value."
::= { stmnCrntPMEntry 25 }
stmnCrntPMRSBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
background block errors value."
::= { stmnCrntPMEntry 26 }
stmnCrntPMRSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section errored seconds."
::= { stmnCrntPMEntry 27 }
stmnCrntPMRSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section errored
seconds value."
::= { stmnCrntPMEntry 28 }
stmnCrntPMRSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
errored seconds value."
::= { stmnCrntPMEntry 29 }
stmnCrntPMRSSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section severely errored seconds."
::= { stmnCrntPMEntry 30 }
stmnCrntPMRSSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section severely
errored seconds value."
::= { stmnCrntPMEntry 31 }
stmnCrntPMRSSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
severely errored seconds value."
::= { stmnCrntPMEntry 32 }
stmnCrntPMRSOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section out-of-frame seconds."
::= { stmnCrntPMEntry 33 }
stmnCrntPMRSOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section
out-of-frame seconds value."
::= { stmnCrntPMEntry 34 }
stmnCrntPMRSOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
out-of-frame seconds value."
::= { stmnCrntPMEntry 35 }
stmnCrntPMSupplyVoltage2Value OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the second supply voltage source measured on the
STM-N facility port transceiver."
::= { stmnCrntPMEntry 36 }
stmnCrntPMSupplyVoltage2TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the second supply voltage value."
::= { stmnCrntPMEntry 37 }
stmnCrntPMSupplyVoltage2Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided second supply voltage
value."
::= { stmnCrntPMEntry 38 }
stmnCrntPMMSEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of multiplex section errored blocks."
::= { stmnCrntPMEntry 39 }
stmnCrntPMMSEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multiplex section errored
blocks value."
::= { stmnCrntPMEntry 40 }
stmnCrntPMMSEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multiplex section
errored blocks value."
::= { stmnCrntPMEntry 41 }
stmnCrntPMMSBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of multiplex section background block errors."
::= { stmnCrntPMEntry 42 }
stmnCrntPMMSBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multiplex section background
block errors value."
::= { stmnCrntPMEntry 43 }
stmnCrntPMMSBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multiplex section
background block errors value."
::= { stmnCrntPMEntry 44 }
stmnCrntPMMSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of multiplex section errored seconds."
::= { stmnCrntPMEntry 45 }
stmnCrntPMMSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multiplex section errored
seconds value."
::= { stmnCrntPMEntry 46 }
stmnCrntPMMSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multiplex section
errored seconds value."
::= { stmnCrntPMEntry 47 }
stmnCrntPMMSSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of multiplex section severely errored seconds."
::= { stmnCrntPMEntry 48 }
stmnCrntPMMSSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multiplex section severely
errored seconds value."
::= { stmnCrntPMEntry 49 }
stmnCrntPMMSSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multiplex section
severely errored seconds value."
::= { stmnCrntPMEntry 50 }
stmnCrntPMMSUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of multiplex section unavailable seconds."
::= { stmnCrntPMEntry 51 }
stmnCrntPMMSUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multiplex section unavailable
seconds value."
::= { stmnCrntPMEntry 52 }
stmnCrntPMMSUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multiplex section
unavailable seconds value."
::= { stmnCrntPMEntry 53 }
stmnCrntPMOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored blocks."
::= { stmnCrntPMEntry 54 }
stmnCrntPMOTUEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored blocks value."
::= { stmnCrntPMEntry 55 }
stmnCrntPMOTUEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored blocks value."
::= { stmnCrntPMEntry 56 }
stmnCrntPMOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer background block
errors."
::= { stmnCrntPMEntry 57 }
stmnCrntPMOTUBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
background block errors value."
::= { stmnCrntPMEntry 58 }
stmnCrntPMOTUBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer background block errors value."
::= { stmnCrntPMEntry 59 }
stmnCrntPMOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored seconds."
::= { stmnCrntPMEntry 60 }
stmnCrntPMOTUESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored seconds value."
::= { stmnCrntPMEntry 61 }
stmnCrntPMOTUESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored seconds value."
::= { stmnCrntPMEntry 62 }
stmnCrntPMOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer severely errored
seconds."
::= { stmnCrntPMEntry 63 }
stmnCrntPMOTUSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
severely errored seconds value."
::= { stmnCrntPMEntry 64 }
stmnCrntPMOTUSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer severely errored seconds value."
::= { stmnCrntPMEntry 65 }
stmnCrntPMOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer out-of-frame seconds."
::= { stmnCrntPMEntry 66 }
stmnCrntPMOTUOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
out-of-frame seconds value."
::= { stmnCrntPMEntry 67 }
stmnCrntPMOTUOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer severely errored framing seconds value."
::= { stmnCrntPMEntry 68 }
stmnCrntPMNBITCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bits corrected. This object applies
only to STM-64 line port provisioned for OTN line mapping."
::= { stmnCrntPMEntry 69 }
stmnCrntPMNBITCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bits corrected
value."
::= { stmnCrntPMEntry 70 }
stmnCrntPMNBITCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bits
corrected value."
::= { stmnCrntPMEntry 71 }
stmnCrntPMNBYTCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bytes corrected. This object
applies only to STM-64 line port provisioned for OTN line
mapping."
::= { stmnCrntPMEntry 72 }
stmnCrntPMNBYTCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bytes corrected
value."
::= { stmnCrntPMEntry 73 }
stmnCrntPMNBYTCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bytes
corrected value."
::= { stmnCrntPMEntry 74 }
stmnCrntPMUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of uncorrectable codewords. This object applies only
to STM-64 line port provisioned for OTN line mapping."
::= { stmnCrntPMEntry 75 }
stmnCrntPMUNCRCDWTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the uncorrectable codewords value."
::= { stmnCrntPMEntry 76 }
stmnCrntPMUNCRCDWValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided uncorrectable codewords
value."
::= { stmnCrntPMEntry 77 }
stmnCrntPMRSEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMRSEBValue object
to 0."
::= { stmnCrntPMEntry 78 }
stmnCrntPMRSBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMRSBBEValue
object to 0."
::= { stmnCrntPMEntry 79 }
stmnCrntPMRSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMRSESValue object
to 0."
::= { stmnCrntPMEntry 80 }
stmnCrntPMRSSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMRSSESValue
object to 0."
::= { stmnCrntPMEntry 81 }
stmnCrntPMRSOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMRSOFSValue
object to 0."
::= { stmnCrntPMEntry 82 }
stmnCrntPMMSEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMMSEBValue object
to 0."
::= { stmnCrntPMEntry 83 }
stmnCrntPMMSBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMMSBBEValue
object to 0."
::= { stmnCrntPMEntry 84 }
stmnCrntPMMSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMMSESValue object
to 0."
::= { stmnCrntPMEntry 85 }
stmnCrntPMMSSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMMSSESValue
object to 0."
::= { stmnCrntPMEntry 86 }
stmnCrntPMMSUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMMSUASValue
object to 0."
::= { stmnCrntPMEntry 87 }
stmnCrntPMOTUEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOTUEBValue
object to 0."
::= { stmnCrntPMEntry 88 }
stmnCrntPMOTUBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOTUBBEValue
object to 0."
::= { stmnCrntPMEntry 89 }
stmnCrntPMOTUESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOTUESValue
object to 0."
::= { stmnCrntPMEntry 90 }
stmnCrntPMOTUSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOTUSESValue
object to 0."
::= { stmnCrntPMEntry 91 }
stmnCrntPMOTUOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOTUOFSValue
object to 0."
::= { stmnCrntPMEntry 92 }
stmnCrntPMNBITCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMNBITCRValue
object to 0."
::= { stmnCrntPMEntry 93 }
stmnCrntPMNBYTCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMNBYTCRValue
object to 0."
::= { stmnCrntPMEntry 94 }
stmnCrntPMUNCRCDWInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMUNCRCDWValue
object to 0."
::= { stmnCrntPMEntry 95 }
stmnCrntPMOTNBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous BER of STM-64 line port provisioned for OTN line mapping."
::= { stmnCrntPMEntry 96 }
stmnCrntPMOTNBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous BER."
::= { stmnCrntPMEntry 97 }
stmnCrntPMOTNBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous BER."
::= { stmnCrntPMEntry 98 }
stmnCrntPMOTNBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOTNBERValue
object to 0."
::= { stmnCrntPMEntry 99 }
stmnCrntPMOTNAVGBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The interval/average BER of STM-64 line port provisioned for OTN line mapping."
::= { stmnCrntPMEntry 100 }
stmnCrntPMOTNAVGBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the interval/average BER."
::= { stmnCrntPMEntry 101 }
stmnCrntPMOTNAVGBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided interval/average BER."
::= { stmnCrntPMEntry 102 }
stmnCrntPMOTNAVGBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOTNAVGBERValue
object to 0."
::= { stmnCrntPMEntry 103 }
stmnCrntPMNBITCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bits corrected. This object applies
only to STM-64 line port provisioned for OTN line mapping."
::= { stmnCrntPMEntry 104 }
stmnCrntPMNBITCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bits corrected
value."
::= { stmnCrntPMEntry 105 }
stmnCrntPMNBITCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bits
corrected value."
::= { stmnCrntPMEntry 106 }
stmnCrntPMNBITCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMNBITCR64BitValue
object to 0."
::= { stmnCrntPMEntry 107 }
stmnCrntPMNBYTCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bytes corrected. This object
applies only to STM-64 line port provisioned for OTN line
mapping."
::= { stmnCrntPMEntry 108 }
stmnCrntPMNBYTCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bytes corrected
value."
::= { stmnCrntPMEntry 109 }
stmnCrntPMNBYTCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bytes
corrected value."
::= { stmnCrntPMEntry 110 }
stmnCrntPMNBYTCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMNBYTCR64BitValue
object to 0."
::= { stmnCrntPMEntry 111 }
stmnCrntPMRSUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section unavailable seconds.
This object applies only to STM-64 line port provisioned
for OTN line mapping."
::= { stmnCrntPMEntry 112 }
stmnCrntPMRSUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section
unavailable seconds value."
::= { stmnCrntPMEntry 113 }
stmnCrntPMRSUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
unavailable seconds value."
::= { stmnCrntPMEntry 114 }
stmnCrntPMRSUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMRSUASValue
object to 0."
::= { stmnCrntPMEntry 115 }
stmnCrntPMOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer unavailable seconds."
::= { stmnCrntPMEntry 116 }
stmnCrntPMOTUUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
unavailable seconds value."
::= { stmnCrntPMEntry 117 }
stmnCrntPMOTUUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer unavailable seconds value."
::= { stmnCrntPMEntry 118 }
stmnCrntPMOTUUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOTUUASValue
object to 0."
::= { stmnCrntPMEntry 119 }
stmnCrntPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { stmnCrntPMEntry 120 }
stmnCrntPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { stmnCrntPMEntry 121 }
stmnCrntPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { stmnCrntPMEntry 122 }
stmnCrntPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOPRMinValue
object to 0."
::= { stmnCrntPMEntry 123 }
stmnCrntPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { stmnCrntPMEntry 124 }
stmnCrntPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { stmnCrntPMEntry 125 }
stmnCrntPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { stmnCrntPMEntry 126 }
stmnCrntPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOPRMaxValue
object to 0."
::= { stmnCrntPMEntry 127 }
stmnCrntPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { stmnCrntPMEntry 128 }
stmnCrntPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { stmnCrntPMEntry 129 }
stmnCrntPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { stmnCrntPMEntry 130 }
stmnCrntPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOPRAvgValue
object to 0."
::= { stmnCrntPMEntry 131 }
stmnCrntPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { stmnCrntPMEntry 132 }
stmnCrntPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { stmnCrntPMEntry 133 }
stmnCrntPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { stmnCrntPMEntry 134 }
stmnCrntPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOPTMinValue
object to 0."
::= { stmnCrntPMEntry 135 }
stmnCrntPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { stmnCrntPMEntry 136 }
stmnCrntPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { stmnCrntPMEntry 137 }
stmnCrntPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { stmnCrntPMEntry 138 }
stmnCrntPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOPTMaxValue
object to 0."
::= { stmnCrntPMEntry 139 }
stmnCrntPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { stmnCrntPMEntry 140 }
stmnCrntPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { stmnCrntPMEntry 141 }
stmnCrntPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { stmnCrntPMEntry 142 }
stmnCrntPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMOPTAvgValue
object to 0."
::= { stmnCrntPMEntry 143 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical SDH STM-N
-- Performance Monitoring statistics
--
-- A listing of historical SDH STM-N PM values is contained in the
-- StmnHistPMEntry of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for set of each historical SDH STM-N PM data.
--
-- The following table lists the objects in each entry of the
-- StmnHistPMEntry.
-----------------------------------------------------------------------
stmnHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF StmnHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the SDH STM-N facilities on the NE."
::= { performance 15 }
stmnHistPMEntry OBJECT-TYPE
SYNTAX StmnHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SDH STM-N historical performance
monitoring table. Each row of this table contains a full set
of PM statistics and related data for a historical measurement
interval for a given STM-N facility."
INDEX { stmnHistPMTypeIdx,
stmnHistPMShelfIdx,
stmnHistPMSlotIdx,
stmnHistPMPortIdx,
stmnHistPMIntervalTypeIdx,
stmnHistPMIntervalIdx }
::= { stmnHistPMTable 1 }
StmnHistPMEntry ::= SEQUENCE { stmnHistPMTypeIdx StmnType,
stmnHistPMShelfIdx INTEGER,
stmnHistPMSlotIdx INTEGER,
stmnHistPMPortIdx INTEGER,
stmnHistPMIntervalTypeIdx PMIntervalType,
stmnHistPMIntervalIdx INTEGER,
stmnHistPMOPRValue FixedX10,
stmnHistPMOPRTimeStamp DateAndTime,
stmnHistPMOPRValidity PMValidity,
stmnHistPMOPTValue FixedX10,
stmnHistPMOPTTimeStamp DateAndTime,
stmnHistPMOPTValidity PMValidity,
stmnHistPMTempValue INTEGER,
stmnHistPMTempTimeStamp DateAndTime,
stmnHistPMTempValidity PMValidity,
stmnHistPMSupplyVoltageValue FixedX10,
stmnHistPMSupplyVoltageTimeStamp DateAndTime,
stmnHistPMSupplyVoltageValidity PMValidity,
stmnHistPMLBCValue INTEGER,
stmnHistPMLBCTimeStamp DateAndTime,
stmnHistPMLBCValidity PMValidity,
stmnHistPMRSEBValue Unsigned32,
stmnHistPMRSEBTimeStamp DateAndTime,
stmnHistPMRSEBValidity PMValidity,
stmnHistPMRSBBEValue Unsigned32,
stmnHistPMRSBBETimeStamp DateAndTime,
stmnHistPMRSBBEValidity PMValidity,
stmnHistPMRSESValue Unsigned32,
stmnHistPMRSESTimeStamp DateAndTime,
stmnHistPMRSESValidity PMValidity,
stmnHistPMRSSESValue Unsigned32,
stmnHistPMRSSESTimeStamp DateAndTime,
stmnHistPMRSSESValidity PMValidity,
stmnHistPMRSOFSValue Unsigned32,
stmnHistPMRSOFSTimeStamp DateAndTime,
stmnHistPMRSOFSValidity PMValidity,
stmnHistPMSupplyVoltage2Value FixedX10,
stmnHistPMSupplyVoltage2TimeStamp DateAndTime,
stmnHistPMSupplyVoltage2Validity PMValidity,
stmnHistPMMSEBValue Unsigned32,
stmnHistPMMSEBTimeStamp DateAndTime,
stmnHistPMMSEBValidity PMValidity,
stmnHistPMMSBBEValue Unsigned32,
stmnHistPMMSBBETimeStamp DateAndTime,
stmnHistPMMSBBEValidity PMValidity,
stmnHistPMMSESValue Unsigned32,
stmnHistPMMSESTimeStamp DateAndTime,
stmnHistPMMSESValidity PMValidity,
stmnHistPMMSSESValue Unsigned32,
stmnHistPMMSSESTimeStamp DateAndTime,
stmnHistPMMSSESValidity PMValidity,
stmnHistPMMSUASValue Unsigned32,
stmnHistPMMSUASTimeStamp DateAndTime,
stmnHistPMMSUASValidity PMValidity,
stmnHistPMOTUEBValue Unsigned32,
stmnHistPMOTUEBTimeStamp DateAndTime,
stmnHistPMOTUEBValidity PMValidity,
stmnHistPMOTUBBEValue Unsigned32,
stmnHistPMOTUBBETimeStamp DateAndTime,
stmnHistPMOTUBBEValidity PMValidity,
stmnHistPMOTUESValue Unsigned32,
stmnHistPMOTUESTimeStamp DateAndTime,
stmnHistPMOTUESValidity PMValidity,
stmnHistPMOTUSESValue Unsigned32,
stmnHistPMOTUSESTimeStamp DateAndTime,
stmnHistPMOTUSESValidity PMValidity,
stmnHistPMOTUOFSValue Unsigned32,
stmnHistPMOTUOFSTimeStamp DateAndTime,
stmnHistPMOTUOFSValidity PMValidity,
stmnHistPMNBITCRValue Unsigned32,
stmnHistPMNBITCRTimeStamp DateAndTime,
stmnHistPMNBITCRValidity PMValidity,
stmnHistPMNBYTCRValue Unsigned32,
stmnHistPMNBYTCRTimeStamp DateAndTime,
stmnHistPMNBYTCRValidity PMValidity,
stmnHistPMUNCRCDWValue Unsigned32,
stmnHistPMUNCRCDWTimeStamp DateAndTime,
stmnHistPMUNCRCDWValidity PMValidity,
stmnHistPMRSEBInitialize InitializeCmd,
stmnHistPMRSBBEInitialize InitializeCmd,
stmnHistPMRSESInitialize InitializeCmd,
stmnHistPMRSSESInitialize InitializeCmd,
stmnHistPMRSOFSInitialize InitializeCmd,
stmnHistPMMSEBInitialize InitializeCmd,
stmnHistPMMSBBEInitialize InitializeCmd,
stmnHistPMMSESInitialize InitializeCmd,
stmnHistPMMSSESInitialize InitializeCmd,
stmnHistPMMSUASInitialize InitializeCmd,
stmnHistPMOTUEBInitialize InitializeCmd,
stmnHistPMOTUBBEInitialize InitializeCmd,
stmnHistPMOTUESInitialize InitializeCmd,
stmnHistPMOTUSESInitialize InitializeCmd,
stmnHistPMOTUOFSInitialize InitializeCmd,
stmnHistPMNBITCRInitialize InitializeCmd,
stmnHistPMNBYTCRInitialize InitializeCmd,
stmnHistPMUNCRCDWInitialize InitializeCmd,
stmnHistPMOTNBERValue DisplayString,
stmnHistPMOTNBERTimeStamp DateAndTime,
stmnHistPMOTNBERValidity PMValidity,
stmnHistPMOTNBERInitialize InitializeCmd,
stmnHistPMOTNAVGBERValue DisplayString,
stmnHistPMOTNAVGBERTimeStamp DateAndTime,
stmnHistPMOTNAVGBERValidity PMValidity,
stmnHistPMOTNAVGBERInitialize InitializeCmd,
stmnHistPMNBITCR64BitValue Unsigned64,
stmnHistPMNBITCR64BitTimeStamp DateAndTime,
stmnHistPMNBITCR64BitValidity PMValidity,
stmnHistPMNBITCR64BitInitialize InitializeCmd,
stmnHistPMNBYTCR64BitValue Unsigned64,
stmnHistPMNBYTCR64BitTimeStamp DateAndTime,
stmnHistPMNBYTCR64BitValidity PMValidity,
stmnHistPMNBYTCR64BitInitialize InitializeCmd,
stmnHistPMRSUASValue Unsigned32,
stmnHistPMRSUASTimeStamp DateAndTime,
stmnHistPMRSUASValidity PMValidity,
stmnHistPMRSUASInitialize InitializeCmd,
stmnHistPMOTUUASValue Unsigned32,
stmnHistPMOTUUASTimeStamp DateAndTime,
stmnHistPMOTUUASValidity PMValidity,
stmnHistPMOTUUASInitialize InitializeCmd,
stmnHistPMOPRMinValue FixedX10,
stmnHistPMOPRMinTimeStamp DateAndTime,
stmnHistPMOPRMinValidity PMValidity,
stmnHistPMOPRMinInitialize InitializeCmd,
stmnHistPMOPRMaxValue FixedX10,
stmnHistPMOPRMaxTimeStamp DateAndTime,
stmnHistPMOPRMaxValidity PMValidity,
stmnHistPMOPRMaxInitialize InitializeCmd,
stmnHistPMOPRAvgValue FixedX10,
stmnHistPMOPRAvgTimeStamp DateAndTime,
stmnHistPMOPRAvgValidity PMValidity,
stmnHistPMOPRAvgInitialize InitializeCmd,
stmnHistPMOPTMinValue FixedX10,
stmnHistPMOPTMinTimeStamp DateAndTime,
stmnHistPMOPTMinValidity PMValidity,
stmnHistPMOPTMinInitialize InitializeCmd,
stmnHistPMOPTMaxValue FixedX10,
stmnHistPMOPTMaxTimeStamp DateAndTime,
stmnHistPMOPTMaxValidity PMValidity,
stmnHistPMOPTMaxInitialize InitializeCmd,
stmnHistPMOPTAvgValue FixedX10,
stmnHistPMOPTAvgTimeStamp DateAndTime,
stmnHistPMOPTAvgValidity PMValidity,
stmnHistPMOPTAvgInitialize InitializeCmd }
stmnHistPMTypeIdx OBJECT-TYPE
SYNTAX StmnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the STM-N facility targeted for PMs."
::= { stmnHistPMEntry 1 }
stmnHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the STM-N facility targeted
for PMs is provisioned."
::= { stmnHistPMEntry 2 }
stmnHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the STM-N facility
targeted for PMs is provisioned."
::= { stmnHistPMEntry 3 }
stmnHistPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the STM-N
facility targeted for PMs is provisioned."
::= { stmnHistPMEntry 4 }
stmnHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { stmnHistPMEntry 5 }
stmnHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { stmnHistPMEntry 6 }
stmnHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the STM-N
facility."
::= { stmnHistPMEntry 7 }
stmnHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { stmnHistPMEntry 8 }
stmnHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { stmnHistPMEntry 9 }
stmnHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the STM-N
facility."
::= { stmnHistPMEntry 10 }
stmnHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { stmnHistPMEntry 11 }
stmnHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { stmnHistPMEntry 12 }
stmnHistPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the STM-N facility port."
::= { stmnHistPMEntry 13 }
stmnHistPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { stmnHistPMEntry 14 }
stmnHistPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { stmnHistPMEntry 15 }
stmnHistPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the STM-N facility port."
::= { stmnHistPMEntry 16 }
stmnHistPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { stmnHistPMEntry 17 }
stmnHistPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { stmnHistPMEntry 18 }
stmnHistPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the STM-N facility port."
::= { stmnHistPMEntry 19 }
stmnHistPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { stmnHistPMEntry 20 }
stmnHistPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { stmnHistPMEntry 21 }
stmnHistPMRSEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section errored blocks."
::= { stmnHistPMEntry 22 }
stmnHistPMRSEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section errored
blocks value."
::= { stmnHistPMEntry 23 }
stmnHistPMRSEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
errored blocks value."
::= { stmnHistPMEntry 24 }
stmnHistPMRSBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section background block errors."
::= { stmnHistPMEntry 25 }
stmnHistPMRSBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section background
block errors value."
::= { stmnHistPMEntry 26 }
stmnHistPMRSBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
background block errors value."
::= { stmnHistPMEntry 27 }
stmnHistPMRSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section errored seconds."
::= { stmnHistPMEntry 28 }
stmnHistPMRSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section errored
seconds value."
::= { stmnHistPMEntry 29 }
stmnHistPMRSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
errored seconds value."
::= { stmnHistPMEntry 30 }
stmnHistPMRSSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section severely errored seconds."
::= { stmnHistPMEntry 31 }
stmnHistPMRSSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section severely
errored seconds value."
::= { stmnHistPMEntry 32 }
stmnHistPMRSSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
severely errored seconds value."
::= { stmnHistPMEntry 33 }
stmnHistPMRSOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section out-of-frame seconds."
::= { stmnHistPMEntry 34 }
stmnHistPMRSOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section
out-of-frame seconds value."
::= { stmnHistPMEntry 35 }
stmnHistPMRSOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
out-of-frame seconds value."
::= { stmnHistPMEntry 36 }
stmnHistPMSupplyVoltage2Value OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the second supply voltage source measured on the
STM-N facility port transceiver."
::= { stmnHistPMEntry 37 }
stmnHistPMSupplyVoltage2TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the second supply voltage value."
::= { stmnHistPMEntry 38 }
stmnHistPMSupplyVoltage2Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided second supply voltage
value."
::= { stmnHistPMEntry 39 }
stmnHistPMMSEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of multiplex section errored blocks."
::= { stmnHistPMEntry 40 }
stmnHistPMMSEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multiplex section errored
blocks value."
::= { stmnHistPMEntry 41 }
stmnHistPMMSEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multiplex section
errored blocks value."
::= { stmnHistPMEntry 42 }
stmnHistPMMSBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of multiplex section background block errors."
::= { stmnHistPMEntry 43 }
stmnHistPMMSBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multiplex section background
block errors value."
::= { stmnHistPMEntry 44 }
stmnHistPMMSBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multiplex section
background block errors value."
::= { stmnHistPMEntry 45 }
stmnHistPMMSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of multiplex section errored seconds."
::= { stmnHistPMEntry 46 }
stmnHistPMMSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multiplex section errored
seconds value."
::= { stmnHistPMEntry 47 }
stmnHistPMMSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multiplex section
errored seconds value."
::= { stmnHistPMEntry 48 }
stmnHistPMMSSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of multiplex section severely errored seconds."
::= { stmnHistPMEntry 49 }
stmnHistPMMSSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multiplex section severely
errored seconds value."
::= { stmnHistPMEntry 50 }
stmnHistPMMSSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multiplex section
severely errored seconds value."
::= { stmnHistPMEntry 51 }
stmnHistPMMSUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of multiplex section unavailable seconds."
::= { stmnHistPMEntry 52 }
stmnHistPMMSUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multiplex section unavailable
seconds value."
::= { stmnHistPMEntry 53 }
stmnHistPMMSUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multiplex section
unavailable seconds value."
::= { stmnHistPMEntry 54 }
stmnHistPMOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored blocks."
::= { stmnHistPMEntry 55 }
stmnHistPMOTUEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored blocks value."
::= { stmnHistPMEntry 56 }
stmnHistPMOTUEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored blocks value."
::= { stmnHistPMEntry 57 }
stmnHistPMOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer background block
errors."
::= { stmnHistPMEntry 58 }
stmnHistPMOTUBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
background block errors value."
::= { stmnHistPMEntry 59 }
stmnHistPMOTUBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer background block errors value."
::= { stmnHistPMEntry 60 }
stmnHistPMOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored seconds."
::= { stmnHistPMEntry 61 }
stmnHistPMOTUESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored seconds value."
::= { stmnHistPMEntry 62 }
stmnHistPMOTUESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored seconds value."
::= { stmnHistPMEntry 63 }
stmnHistPMOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer severely errored
seconds."
::= { stmnHistPMEntry 64 }
stmnHistPMOTUSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
severely errored seconds value."
::= { stmnHistPMEntry 65 }
stmnHistPMOTUSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer severely errored seconds value."
::= { stmnHistPMEntry 66 }
stmnHistPMOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer out-of-frame seconds."
::= { stmnHistPMEntry 67 }
stmnHistPMOTUOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
out-of-frame seconds value."
::= { stmnHistPMEntry 68 }
stmnHistPMOTUOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer severely errored framing seconds value."
::= { stmnHistPMEntry 69 }
stmnHistPMNBITCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bits corrected. This object applies
only to STM-64 line port provisioned for OTN line mapping."
::= { stmnHistPMEntry 70 }
stmnHistPMNBITCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bits corrected
value."
::= { stmnHistPMEntry 71 }
stmnHistPMNBITCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bits
corrected value."
::= { stmnHistPMEntry 72 }
stmnHistPMNBYTCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bytes corrected. This object
applies only to STM-64 line port provisioned for OTN line
mapping."
::= { stmnHistPMEntry 73 }
stmnHistPMNBYTCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bytes corrected
value."
::= { stmnHistPMEntry 74 }
stmnHistPMNBYTCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bytes
corrected value."
::= { stmnHistPMEntry 75 }
stmnHistPMUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of uncorrectable codewords. This object applies only
to STM-64 line port provisioned for OTN line mapping."
::= { stmnHistPMEntry 76 }
stmnHistPMUNCRCDWTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the uncorrectable codewords value."
::= { stmnHistPMEntry 77 }
stmnHistPMUNCRCDWValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided uncorrectable codewords
value."
::= { stmnHistPMEntry 78 }
stmnHistPMRSEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMRSEBValue object
to 0."
::= { stmnHistPMEntry 79 }
stmnHistPMRSBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMRSBBEValue
object to 0."
::= { stmnHistPMEntry 80 }
stmnHistPMRSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMRSESValue object
to 0."
::= { stmnHistPMEntry 81 }
stmnHistPMRSSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMRSSESValue
object to 0."
::= { stmnHistPMEntry 82 }
stmnHistPMRSOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMRSOFSValue
object to 0."
::= { stmnHistPMEntry 83 }
stmnHistPMMSEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMMSEBValue object
to 0."
::= { stmnHistPMEntry 84 }
stmnHistPMMSBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMMSBBEValue
object to 0."
::= { stmnHistPMEntry 85 }
stmnHistPMMSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMMSESValue object
to 0."
::= { stmnHistPMEntry 86 }
stmnHistPMMSSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMMSSESValue
object to 0."
::= { stmnHistPMEntry 87 }
stmnHistPMMSUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMMSUASValue
object to 0."
::= { stmnHistPMEntry 88 }
stmnHistPMOTUEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOTUEBValue
object to 0."
::= { stmnHistPMEntry 89 }
stmnHistPMOTUBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOTUBBEValue
object to 0."
::= { stmnHistPMEntry 90 }
stmnHistPMOTUESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOTUESValue
object to 0."
::= { stmnHistPMEntry 91 }
stmnHistPMOTUSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOTUSESValue
object to 0."
::= { stmnHistPMEntry 92 }
stmnHistPMOTUOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOTUOFSValue
object to 0."
::= { stmnHistPMEntry 93 }
stmnHistPMNBITCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMNBITCRValue
object to 0."
::= { stmnHistPMEntry 94 }
stmnHistPMNBYTCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMNBYTCRValue
object to 0."
::= { stmnHistPMEntry 95 }
stmnHistPMUNCRCDWInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMUNCRCDWValue
object to 0."
::= { stmnHistPMEntry 96 }
stmnHistPMOTNBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous BER of STM-64 line port provisioned for OTN line mapping."
::= { stmnHistPMEntry 97 }
stmnHistPMOTNBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous BER."
::= { stmnHistPMEntry 98 }
stmnHistPMOTNBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous BER."
::= { stmnHistPMEntry 99 }
stmnHistPMOTNBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOTNBERValue
object to 0."
::= { stmnHistPMEntry 100 }
stmnHistPMOTNAVGBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The interval/average BER of STM-64 line port provisioned for OTN line mapping."
::= { stmnHistPMEntry 101 }
stmnHistPMOTNAVGBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the interval/average BER."
::= { stmnHistPMEntry 102 }
stmnHistPMOTNAVGBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided interval/average BER."
::= { stmnHistPMEntry 103 }
stmnHistPMOTNAVGBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOTNAVGBERValue
object to 0."
::= { stmnHistPMEntry 104 }
stmnHistPMNBITCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bits corrected. This object applies
only to STM-64 line port provisioned for OTN line mapping."
::= { stmnHistPMEntry 105 }
stmnHistPMNBITCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bits corrected
value."
::= { stmnHistPMEntry 106 }
stmnHistPMNBITCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bits
corrected value."
::= { stmnHistPMEntry 107 }
stmnHistPMNBITCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMNBITCR64BitValue
object to 0."
::= { stmnHistPMEntry 108 }
stmnHistPMNBYTCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bytes corrected. This object
applies only to STM-64 line port provisioned for OTN line
mapping."
::= { stmnHistPMEntry 109 }
stmnHistPMNBYTCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bytes corrected
value."
::= { stmnHistPMEntry 110 }
stmnHistPMNBYTCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bytes
corrected value."
::= { stmnHistPMEntry 111 }
stmnHistPMNBYTCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnCrntPMNBYTCR64BitValue
object to 0."
::= { stmnHistPMEntry 112 }
stmnHistPMRSUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of regenerator section unavailable seconds.
This object applies only to STM-64 line port provisioned
for OTN line mapping."
::= { stmnHistPMEntry 113 }
stmnHistPMRSUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the regenerator section
unavailable seconds value."
::= { stmnHistPMEntry 114 }
stmnHistPMRSUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided regenerator section
unavailable seconds value."
::= { stmnHistPMEntry 115 }
stmnHistPMRSUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMRSUASValue
object to 0."
::= { stmnHistPMEntry 116 }
stmnHistPMOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer unavailable seconds."
::= { stmnHistPMEntry 117 }
stmnHistPMOTUUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
unavailable seconds value."
::= { stmnHistPMEntry 118 }
stmnHistPMOTUUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer unavailable seconds value."
::= { stmnHistPMEntry 119 }
stmnHistPMOTUUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOTUUASValue
object to 0."
::= { stmnHistPMEntry 120 }
stmnHistPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { stmnHistPMEntry 121 }
stmnHistPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { stmnHistPMEntry 122 }
stmnHistPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { stmnHistPMEntry 123 }
stmnHistPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOPRMinValue
object to 0."
::= { stmnHistPMEntry 124 }
stmnHistPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { stmnHistPMEntry 125 }
stmnHistPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { stmnHistPMEntry 126 }
stmnHistPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { stmnHistPMEntry 127 }
stmnHistPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOPRMaxValue
object to 0."
::= { stmnHistPMEntry 128 }
stmnHistPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { stmnHistPMEntry 129 }
stmnHistPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { stmnHistPMEntry 130 }
stmnHistPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { stmnHistPMEntry 131 }
stmnHistPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOPRAvgValue
object to 0."
::= { stmnHistPMEntry 132 }
stmnHistPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { stmnHistPMEntry 133 }
stmnHistPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { stmnHistPMEntry 134 }
stmnHistPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { stmnHistPMEntry 135 }
stmnHistPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOPTMinValue
object to 0."
::= { stmnHistPMEntry 136 }
stmnHistPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { stmnHistPMEntry 137 }
stmnHistPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { stmnHistPMEntry 138 }
stmnHistPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { stmnHistPMEntry 139 }
stmnHistPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOPTMaxValue
object to 0."
::= { stmnHistPMEntry 140 }
stmnHistPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { stmnHistPMEntry 141 }
stmnHistPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { stmnHistPMEntry 142 }
stmnHistPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { stmnHistPMEntry 143 }
stmnHistPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the stmnHistPMOPTAvgValue
object to 0."
::= { stmnHistPMEntry 144 }
-----------------------------------------------------------------------
-- Objects used to manage SDH STM-N
-- Monitoring Threshold Levels
--
-- A listing of SDH STM-N PM threshold levels is contained in the
-- stsmPMThresholdTable of the BTI-7000-MIB. When retrieved, this
-- table provides one row for each set of SDH STM-N PM threshold data.
--
-- The following table lists the objects in each entry of the
-- stsmPMThresholdTable.
-----------------------------------------------------------------------
stmnPMThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF StmnPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of threshold levels for performance monitoring counter
values on SDH STM-N facilities, that are used in the
generation of threshold crossing alerts."
::= { performance 16 }
stmnPMThresholdEntry OBJECT-TYPE
SYNTAX StmnPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SDH STM-N performance monitoring
threshold table. Each row of this table contains a set of PM
thresholds for a given interval type that applies to an
individual STM-N facility."
INDEX { stmnPMThresholdTypeIdx,
stmnPMThresholdShelfIdx,
stmnPMThresholdSlotIdx,
stmnPMThresholdPortIdx,
stmnPMThresholdIntervalTypeIdx }
::= { stmnPMThresholdTable 1 }
StmnPMThresholdEntry ::= SEQUENCE { stmnPMThresholdTypeIdx StmnType,
stmnPMThresholdShelfIdx INTEGER,
stmnPMThresholdSlotIdx INTEGER,
stmnPMThresholdPortIdx INTEGER,
stmnPMThresholdIntervalTypeIdx PMIntervalType,
stmnPMThresholdRSEBValue Unsigned32,
stmnPMThresholdRSBBEValue Unsigned32,
stmnPMThresholdRSESValue Unsigned32,
stmnPMThresholdRSSESValue Unsigned32,
stmnPMThresholdRSOFSValue Unsigned32,
stmnPMThresholdMSEBValue Unsigned32,
stmnPMThresholdMSBBEValue Unsigned32,
stmnPMThresholdMSESValue Unsigned32,
stmnPMThresholdMSSESValue Unsigned32,
stmnPMThresholdMSUASValue Unsigned32,
stmnPMThresholdOTUEBValue Unsigned32,
stmnPMThresholdOTUBBEValue Unsigned32,
stmnPMThresholdOTUESValue Unsigned32,
stmnPMThresholdOTUSESValue Unsigned32,
stmnPMThresholdOTUOFSValue Unsigned32,
stmnPMThresholdUNCRCDWValue Unsigned32,
stmnPMThresholdRSUASValue Unsigned32,
stmnPMThresholdOTUUASValue Unsigned32 }
stmnPMThresholdTypeIdx OBJECT-TYPE
SYNTAX StmnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the STM-N facility targeted for PM thresholds."
::= { stmnPMThresholdEntry 1 }
stmnPMThresholdShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The shelf number on which the STM-N facility targeted for PM
thresholds is provisioned."
::= { stmnPMThresholdEntry 2 }
stmnPMThresholdSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The slot number on which the STM-N facility targeted for PM
thresholds is provisioned."
::= { stmnPMThresholdEntry 3 }
stmnPMThresholdPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the STM-N
facility targeted for PM thresholds is provisioned."
::= { stmnPMThresholdEntry 4 }
stmnPMThresholdIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length. Thresholds
are supported for the 15-minute and 1-day PM bins only."
::= { stmnPMThresholdEntry 5 }
stmnPMThresholdRSEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section errored
blocks."
::= { stmnPMThresholdEntry 6 }
stmnPMThresholdRSBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section background
block errors."
::= { stmnPMThresholdEntry 7 }
stmnPMThresholdRSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section errored
seconds."
::= { stmnPMThresholdEntry 8 }
stmnPMThresholdRSSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section severely
errored seconds."
::= { stmnPMThresholdEntry 9 }
stmnPMThresholdRSOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section
out-of-frame seconds."
::= { stmnPMThresholdEntry 10 }
stmnPMThresholdMSEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of multiplex section errored
blocks."
::= { stmnPMThresholdEntry 11 }
stmnPMThresholdMSBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of multiplex section background
block errors."
::= { stmnPMThresholdEntry 12 }
stmnPMThresholdMSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of multiplex section errored
seconds."
::= { stmnPMThresholdEntry 13 }
stmnPMThresholdMSSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of multiplex section severely
errored seconds."
::= { stmnPMThresholdEntry 14 }
stmnPMThresholdMSUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of multiplex section unavailable
seconds."
::= { stmnPMThresholdEntry 15 }
stmnPMThresholdOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of OTU digital wrapper layer
errored blocks."
::= { stmnPMThresholdEntry 16 }
stmnPMThresholdOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of OTU digital wrapper layer
background block errors."
::= { stmnPMThresholdEntry 17 }
stmnPMThresholdOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of OTU digital wrapper layer
errored seconds."
::= { stmnPMThresholdEntry 18 }
stmnPMThresholdOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of OTU digital wrapper layer
severely errored seconds."
::= { stmnPMThresholdEntry 19 }
stmnPMThresholdOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of OTU digital wrapper layer
out-of-frame seconds."
::= { stmnPMThresholdEntry 20 }
stmnPMThresholdUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of uncorrectable codewords."
::= { stmnPMThresholdEntry 23 }
stmnPMThresholdRSUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of regenerator section
unavailable seconds."
::= { stmnPMThresholdEntry 24 }
stmnPMThresholdOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of OTU digital wrapper layer
unavailable seconds."
::= { stmnPMThresholdEntry 25 }
-----------------------------------------------------------------------
-- Objects used to retrieve current SDH VC-N
-- Performance Monitoring statistics
--
-- A listing of current SDH VC-N PM values is contained in the
-- vcnCrntPMTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each set of current SDH VC-N PM data.
--
-- The following table lists the objects in each entry of the
-- vcnCrntPMTable.
-----------------------------------------------------------------------
vcnCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcnCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the SDH VC-N facilities on the NE."
::= { performance 17 }
vcnCrntPMEntry OBJECT-TYPE
SYNTAX VcnCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SDH VC-N current performance
monitoring table. Each row of this table contains a full set
of PM statistics and related data for a current measurement
interval for a given VC-N facility."
INDEX { vcnCrntPMTypeIdx,
vcnCrntPMShelfIdx,
vcnCrntPMSlotIdx,
vcnCrntPMPortIdx,
vcnCrntPMIdx,
vcnCrntPMIntervalTypeIdx }
::= { vcnCrntPMTable 1 }
VcnCrntPMEntry ::= SEQUENCE { vcnCrntPMTypeIdx VcnType,
vcnCrntPMShelfIdx INTEGER,
vcnCrntPMSlotIdx INTEGER,
vcnCrntPMPortIdx INTEGER,
vcnCrntPMIdx INTEGER,
vcnCrntPMIntervalTypeIdx PMIntervalType,
vcnCrntPMHPEBValue Unsigned32,
vcnCrntPMHPEBTimeStamp DateAndTime,
vcnCrntPMHPEBValidity PMValidity,
vcnCrntPMHPBBEValue Unsigned32,
vcnCrntPMHPBBETimeStamp DateAndTime,
vcnCrntPMHPBBEValidity PMValidity,
vcnCrntPMHPESValue Unsigned32,
vcnCrntPMHPESTimeStamp DateAndTime,
vcnCrntPMHPESValidity PMValidity,
vcnCrntPMHPSESValue Unsigned32,
vcnCrntPMHPSESTimeStamp DateAndTime,
vcnCrntPMHPSESValidity PMValidity,
vcnCrntPMHPUASValue Unsigned32,
vcnCrntPMHPUASTimeStamp DateAndTime,
vcnCrntPMHPUASValidity PMValidity,
vcnCrntPMHPEBInitialize InitializeCmd,
vcnCrntPMHPBBEInitialize InitializeCmd,
vcnCrntPMHPESInitialize InitializeCmd,
vcnCrntPMHPSESInitialize InitializeCmd,
vcnCrntPMHPUASInitialize InitializeCmd }
vcnCrntPMTypeIdx OBJECT-TYPE
SYNTAX VcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of VC-N facility targeted for PMs."
::= { vcnCrntPMEntry 1 }
vcnCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the VC-N facility targeted for
PMs."
::= { vcnCrntPMEntry 2 }
vcnCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the VC-N facility targeted for PMs."
::= { vcnCrntPMEntry 3 }
vcnCrntPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack of the VC-N
facility targeted for PMs."
::= { vcnCrntPMEntry 4 }
vcnCrntPMIdx OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The channel number of the VC-N facility targeted for PMs."
::= { vcnCrntPMEntry 5 }
vcnCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { vcnCrntPMEntry 6 }
vcnCrntPMHPEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of high order path errored blocks."
::= { vcnCrntPMEntry 7 }
vcnCrntPMHPEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the high order path errored blocks
value."
::= { vcnCrntPMEntry 8 }
vcnCrntPMHPEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided high order path errored
blocks value."
::= { vcnCrntPMEntry 9 }
vcnCrntPMHPBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of high order path background block errors."
::= { vcnCrntPMEntry 10 }
vcnCrntPMHPBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the high order path background
block errors value."
::= { vcnCrntPMEntry 11 }
vcnCrntPMHPBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided high order path
background block errors value."
::= { vcnCrntPMEntry 12 }
vcnCrntPMHPESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of high order path errored seconds."
::= { vcnCrntPMEntry 13 }
vcnCrntPMHPESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the high order path errored seconds
value."
::= { vcnCrntPMEntry 14 }
vcnCrntPMHPESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided high order path errored
seconds value."
::= { vcnCrntPMEntry 15 }
vcnCrntPMHPSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of high order path severely errored seconds."
::= { vcnCrntPMEntry 16 }
vcnCrntPMHPSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the high order path severely
errored seconds value."
::= { vcnCrntPMEntry 17 }
vcnCrntPMHPSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided high order path
severely errored seconds value."
::= { vcnCrntPMEntry 18 }
vcnCrntPMHPUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of high order path unavailable seconds."
::= { vcnCrntPMEntry 19 }
vcnCrntPMHPUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the high order path unavailable
seconds value."
::= { vcnCrntPMEntry 20 }
vcnCrntPMHPUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided high order path
unavailable seconds value."
::= { vcnCrntPMEntry 21 }
vcnCrntPMHPEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the vcnCrntPMHPEBValue object
to 0."
::= { vcnCrntPMEntry 22 }
vcnCrntPMHPBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the vcnCrntPMHPBBEValue object
to 0."
::= { vcnCrntPMEntry 23 }
vcnCrntPMHPESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the vcnCrntPMHPESValue object
to 0."
::= { vcnCrntPMEntry 24 }
vcnCrntPMHPSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the vcnCrntPMHPSESValue object
to 0."
::= { vcnCrntPMEntry 25 }
vcnCrntPMHPUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the vcnCrntPMHPUASValue object
to 0."
::= { vcnCrntPMEntry 26 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical SDH VC-N
-- Performance Monitoring statistics
--
-- A listing of historical SDH VC-N PM values is contained in the
-- vcnHistPMTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each set of historical SDH VC-N PM data.
--
-- The following table lists the objects in each entry of the
-- vcnHistPMTable.
-----------------------------------------------------------------------
vcnHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcnHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the SDH VC-N facilities on the NE."
::= { performance 18 }
vcnHistPMEntry OBJECT-TYPE
SYNTAX VcnHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SDH VC-N historical performance
monitoring table. Each row of this table contains a full set
of PM statistics and related data for a historical measurement
interval for a given VC-N facility."
INDEX { vcnHistPMTypeIdx,
vcnHistPMShelfIdx,
vcnHistPMSlotIdx,
vcnHistPMPortIdx,
vcnHistPMIdx,
vcnHistPMIntervalTypeIdx,
vcnHistPMIntervalIdx }
::= { vcnHistPMTable 1 }
VcnHistPMEntry ::= SEQUENCE { vcnHistPMTypeIdx VcnType,
vcnHistPMShelfIdx INTEGER,
vcnHistPMSlotIdx INTEGER,
vcnHistPMPortIdx INTEGER,
vcnHistPMIdx INTEGER,
vcnHistPMIntervalTypeIdx PMIntervalType,
vcnHistPMIntervalIdx INTEGER,
vcnHistPMHPEBValue Unsigned32,
vcnHistPMHPEBTimeStamp DateAndTime,
vcnHistPMHPEBValidity PMValidity,
vcnHistPMHPBBEValue Unsigned32,
vcnHistPMHPBBETimeStamp DateAndTime,
vcnHistPMHPBBEValidity PMValidity,
vcnHistPMHPESValue Unsigned32,
vcnHistPMHPESTimeStamp DateAndTime,
vcnHistPMHPESValidity PMValidity,
vcnHistPMHPSESValue Unsigned32,
vcnHistPMHPSESTimeStamp DateAndTime,
vcnHistPMHPSESValidity PMValidity,
vcnHistPMHPUASValue Unsigned32,
vcnHistPMHPUASTimeStamp DateAndTime,
vcnHistPMHPUASValidity PMValidity,
vcnHistPMHPEBInitialize InitializeCmd,
vcnHistPMHPBBEInitialize InitializeCmd,
vcnHistPMHPESInitialize InitializeCmd,
vcnHistPMHPSESInitialize InitializeCmd,
vcnHistPMHPUASInitialize InitializeCmd }
vcnHistPMTypeIdx OBJECT-TYPE
SYNTAX VcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the VC-N facility targeted for PMs."
::= { vcnHistPMEntry 1 }
vcnHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the VC-N facility targeted for
PMs."
::= { vcnHistPMEntry 2 }
vcnHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the VC-N facility targeted for PMs."
::= { vcnHistPMEntry 3 }
vcnHistPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack of the VC-N
facility targeted for PMs."
::= { vcnHistPMEntry 4 }
vcnHistPMIdx OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The channel number of the VC-N facility targeted for PMs."
::= { vcnHistPMEntry 5 }
vcnHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { vcnHistPMEntry 6 }
vcnHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { vcnHistPMEntry 7 }
vcnHistPMHPEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of high order path errored blocks."
::= { vcnHistPMEntry 8 }
vcnHistPMHPEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the high order path errored blocks
value."
::= { vcnHistPMEntry 9 }
vcnHistPMHPEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided high order path errored
blocks value."
::= { vcnHistPMEntry 10 }
vcnHistPMHPBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of high order path background block errors."
::= { vcnHistPMEntry 11 }
vcnHistPMHPBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the high order path background
block errors value."
::= { vcnHistPMEntry 12 }
vcnHistPMHPBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided high order path
background block errors value."
::= { vcnHistPMEntry 13 }
vcnHistPMHPESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of high order path errored seconds."
::= { vcnHistPMEntry 14 }
vcnHistPMHPESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the high order path errored seconds
value."
::= { vcnHistPMEntry 15 }
vcnHistPMHPESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the high order path errored seconds
value."
::= { vcnHistPMEntry 16 }
vcnHistPMHPSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of high order path severely errored seconds."
::= { vcnHistPMEntry 17 }
vcnHistPMHPSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the high order path severely
errored seconds value."
::= { vcnHistPMEntry 18 }
vcnHistPMHPSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided high order path
severely errored seconds value."
::= { vcnHistPMEntry 19 }
vcnHistPMHPUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of high order path unavailable seconds."
::= { vcnHistPMEntry 20 }
vcnHistPMHPUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the high order path unavailable
seconds value."
::= { vcnHistPMEntry 21 }
vcnHistPMHPUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided high order path
unavailable seconds value."
::= { vcnHistPMEntry 22 }
vcnHistPMHPEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the vcnHistPMHPEBValue object
to 0."
::= { vcnHistPMEntry 23 }
vcnHistPMHPBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the vcnHistPMHPBBEValue object
to 0."
::= { vcnHistPMEntry 24 }
vcnHistPMHPESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the vcnHistPMHPESValue object
to 0."
::= { vcnHistPMEntry 25 }
vcnHistPMHPSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the vcnHistPMHPSESValue object
to 0."
::= { vcnHistPMEntry 26 }
vcnHistPMHPUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the vcnHistPMHPUASValue object
to 0."
::= { vcnHistPMEntry 27 }
-----------------------------------------------------------------------
-- Objects used to manage SDH VC-N Performance
-- Monitoring Threshold Levels
--
-- A listing of SDH VC-N PM threshold levels is contained in the
-- VcnPMThresholdByPortEntry of the BTI-7000-MIB. When retrieved, this
-- table provides one row for each set of SDH VC-N PM threshold data.
--
-- The following table lists the objects in each entry of the
-- VcnPMThresholdByPortEntry.
-----------------------------------------------------------------------
vcnPMThresholdByPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcnPMThresholdByPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of threshold levels for performance monitoring counter
values on SDH VC-N facilities, that are used in the generation
of threshold crossing alerts. The VC-N threshold settings will
be the same for all channels on a given STM-N facility port."
::= { performance 19 }
vcnPMThresholdByPortEntry OBJECT-TYPE
SYNTAX VcnPMThresholdByPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the SDH STM-N performance monitoring
threshold by port table. Each row of this table contains a set
of PM thresholds for a given interval type that applies to all
the VC-N channels on an STM-N facility port."
INDEX { vcnPMThresholdByPortTypeIdx,
vcnPMThresholdByPortShelfIdx,
vcnPMThresholdByPortSlotIdx,
vcnPMThresholdByPortIdx,
vcnPMThresholdByPortIntervalTypeIdx }
::= { vcnPMThresholdByPortTable 1 }
VcnPMThresholdByPortEntry ::= SEQUENCE { vcnPMThresholdByPortTypeIdx VcnType,
vcnPMThresholdByPortShelfIdx INTEGER,
vcnPMThresholdByPortSlotIdx INTEGER,
vcnPMThresholdByPortIdx INTEGER,
vcnPMThresholdByPortIntervalTypeIdx PMIntervalType,
vcnPMThresholdByPortHPEBValue Unsigned32,
vcnPMThresholdByPortHPBBEValue Unsigned32,
vcnPMThresholdByPortHPESValue Unsigned32,
vcnPMThresholdByPortHPSESValue Unsigned32,
vcnPMThresholdByPortHPUASValue Unsigned32 }
vcnPMThresholdByPortTypeIdx OBJECT-TYPE
SYNTAX VcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the VC-N facility targeted for PM thresholds."
::= { vcnPMThresholdByPortEntry 1 }
vcnPMThresholdByPortShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The shelf number of the VC-N facilities targeted for PM
thresholds."
::= { vcnPMThresholdByPortEntry 2 }
vcnPMThresholdByPortSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The slot number of the VC-N facilities targeted for PM
thresholds."
::= { vcnPMThresholdByPortEntry 3 }
vcnPMThresholdByPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack of the VC-N
facilities targeted for PM thresholds."
::= { vcnPMThresholdByPortEntry 4 }
vcnPMThresholdByPortIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length. Thresholds
are supported for the 15-minute and 1-day PM bins only."
::= { vcnPMThresholdByPortEntry 5 }
vcnPMThresholdByPortHPEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of high order path errored
blocks."
::= { vcnPMThresholdByPortEntry 6 }
vcnPMThresholdByPortHPBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of high order path background
block errors."
::= { vcnPMThresholdByPortEntry 7 }
vcnPMThresholdByPortHPESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of high order path errored
seconds."
::= { vcnPMThresholdByPortEntry 8 }
vcnPMThresholdByPortHPSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of high order path severely
errored seconds."
::= { vcnPMThresholdByPortEntry 9 }
vcnPMThresholdByPortHPUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of high order path unavailable
seconds."
::= { vcnPMThresholdByPortEntry 10 }
-----------------------------------------------------------------------
-- Objects used to retrieve current Gigabit Ethernet
-- Performance Monitoring statistics
--
-- A listing of current Gigabit Ethernet PM values is contained in the
-- geCrntPMTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each set of current Gigabit Ethernet
-- PM data.
--
-- The following table lists the objects in each entry of the
-- geCrntPMTable.
-----------------------------------------------------------------------
geCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF GeCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the Gigabit Ethernet facilities on the NE."
::= { performance 20 }
geCrntPMEntry OBJECT-TYPE
SYNTAX GeCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Gigabit Ethernet current
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a current
measurement interval for a given Gigabit Ethernet facility."
INDEX { geCrntPMShelfIdx,
geCrntPMSlotIdx,
geCrntPMPortIdx,
geCrntPMIntervalTypeIdx }
::= { geCrntPMTable 1 }
GeCrntPMEntry ::= SEQUENCE { geCrntPMShelfIdx INTEGER,
geCrntPMSlotIdx INTEGER,
geCrntPMPortIdx INTEGER,
geCrntPMIntervalTypeIdx PMIntervalType,
geCrntPMOPRValue FixedX10,
geCrntPMOPRTimeStamp DateAndTime,
geCrntPMOPRValidity PMValidity,
geCrntPMOPTValue FixedX10,
geCrntPMOPTTimeStamp DateAndTime,
geCrntPMOPTValidity PMValidity,
geCrntPMTempValue INTEGER,
geCrntPMTempTimeStamp DateAndTime,
geCrntPMTempValidity PMValidity,
geCrntPMSupplyVoltageValue FixedX10,
geCrntPMSupplyVoltageTimeStamp DateAndTime,
geCrntPMSupplyVoltageValidity PMValidity,
geCrntPMLBCValue INTEGER,
geCrntPMLBCTimeStamp DateAndTime,
geCrntPMLBCValidity PMValidity,
geCrntPMCVValue Unsigned32,
geCrntPMCVTimeStamp DateAndTime,
geCrntPMCVValidity PMValidity,
geCrntPMESValue Unsigned32,
geCrntPMESTimeStamp DateAndTime,
geCrntPMESValidity PMValidity,
geCrntPMSESValue Unsigned32,
geCrntPMSESTimeStamp DateAndTime,
geCrntPMSESValidity PMValidity,
geCrntPMTFRCRXValue Unsigned64,
geCrntPMTFRCRXTimeStamp DateAndTime,
geCrntPMTFRCRXValidity PMValidity,
geCrntPMTFRCRXInitialize InitializeCmd,
geCrntPMTFRCTXValue Unsigned64,
geCrntPMTFRCTXTimeStamp DateAndTime,
geCrntPMTFRCTXValidity PMValidity,
geCrntPMTFRCTXInitialize InitializeCmd,
geCrntPMFRDRValue Unsigned32,
geCrntPMFRDRTimeStamp DateAndTime,
geCrntPMFRDRValidity PMValidity,
geCrntPMFCSEValue Unsigned32,
geCrntPMFCSETimeStamp DateAndTime,
geCrntPMFCSEValidity PMValidity,
geCrntPMTBYCRXValue Unsigned64,
geCrntPMTBYCRXTimeStamp DateAndTime,
geCrntPMTBYCRXValidity PMValidity,
geCrntPMTBYCRXInitialize InitializeCmd,
geCrntPMTBYCTXValue Unsigned64,
geCrntPMTBYCTXTimeStamp DateAndTime,
geCrntPMTBYCTXValidity PMValidity,
geCrntPMTBYCTXInitialize InitializeCmd,
geCrntPMBCSTValue Unsigned64,
geCrntPMBCSTTimeStamp DateAndTime,
geCrntPMBCSTValidity PMValidity,
geCrntPMBCSTInitialize InitializeCmd,
geCrntPMMCSTValue Unsigned64,
geCrntPMMCSTTimeStamp DateAndTime,
geCrntPMMCSTValidity PMValidity,
geCrntPMMCSTInitialize InitializeCmd,
geCrntPMSIZE64Value Unsigned64,
geCrntPMSIZE64TimeStamp DateAndTime,
geCrntPMSIZE64Validity PMValidity,
geCrntPMSIZE64Initialize InitializeCmd,
geCrntPMSIZE65To127Value Unsigned64,
geCrntPMSIZE65To127TimeStamp DateAndTime,
geCrntPMSIZE65To127Validity PMValidity,
geCrntPMSIZE65To127Initialize InitializeCmd,
geCrntPMSIZE128To255Value Unsigned64,
geCrntPMSIZE128To255TimeStamp DateAndTime,
geCrntPMSIZE128To255Validity PMValidity,
geCrntPMSIZE128To255Initialize InitializeCmd,
geCrntPMSIZE256To511Value Unsigned64,
geCrntPMSIZE256To511TimeStamp DateAndTime,
geCrntPMSIZE256To511Validity PMValidity,
geCrntPMSIZE256To511Initialize InitializeCmd,
geCrntPMSIZE512To1023Value Unsigned64,
geCrntPMSIZE512To1023TimeStamp DateAndTime,
geCrntPMSIZE512To1023Validity PMValidity,
geCrntPMSIZE512To1023Initialize InitializeCmd,
geCrntPMSIZE1024To1518Value Unsigned64,
geCrntPMSIZE1024To1518TimeStamp DateAndTime,
geCrntPMSIZE1024To1518Validity PMValidity,
geCrntPMSIZE1024To1518Initialize InitializeCmd,
geCrntPMSIZEOver1518Value Unsigned64,
geCrntPMSIZEOver1518TimeStamp DateAndTime,
geCrntPMSIZEOver1518Validity PMValidity,
geCrntPMSIZEOver1518Initialize InitializeCmd,
geCrntPMTPFCRXValue Unsigned64,
geCrntPMTPFCRXTimeStamp DateAndTime,
geCrntPMTPFCRXValidity PMValidity,
geCrntPMTPFCRXInitialize InitializeCmd,
geCrntPMTPFCTXValue Unsigned64,
geCrntPMTPFCTXTimeStamp DateAndTime,
geCrntPMTPFCTXValidity PMValidity,
geCrntPMTPFCTXInitialize InitializeCmd,
geCrntPMUSIZEValue Unsigned32,
geCrntPMUSIZETimeStamp DateAndTime,
geCrntPMUSIZEValidity PMValidity,
geCrntPMOSIZEValue Unsigned32,
geCrntPMOSIZETimeStamp DateAndTime,
geCrntPMOSIZEValidity PMValidity,
geCrntPMFRGTValue Unsigned32,
geCrntPMFRGTTimeStamp DateAndTime,
geCrntPMFRGTValidity PMValidity,
geCrntPMJABRValue Unsigned32,
geCrntPMJABRTimeStamp DateAndTime,
geCrntPMJABRValidity PMValidity,
geCrntPMCVInitialize InitializeCmd,
geCrntPMESInitialize InitializeCmd,
geCrntPMSESInitialize InitializeCmd,
geCrntPMFCSEInitialize InitializeCmd,
geCrntPMFRDRInitialize InitializeCmd,
geCrntPMUSIZEInitialize InitializeCmd,
geCrntPMOSIZEInitialize InitializeCmd,
geCrntPMFRGTInitialize InitializeCmd,
geCrntPMJABRInitialize InitializeCmd,
geCrntPMUASValue Unsigned32,
geCrntPMUASTimeStamp DateAndTime,
geCrntPMUASValidity PMValidity,
geCrntPMUASInitialize InitializeCmd,
geCrntPMOPRMinValue FixedX10,
geCrntPMOPRMinTimeStamp DateAndTime,
geCrntPMOPRMinValidity PMValidity,
geCrntPMOPRMinInitialize InitializeCmd,
geCrntPMOPRMaxValue FixedX10,
geCrntPMOPRMaxTimeStamp DateAndTime,
geCrntPMOPRMaxValidity PMValidity,
geCrntPMOPRMaxInitialize InitializeCmd,
geCrntPMOPRAvgValue FixedX10,
geCrntPMOPRAvgTimeStamp DateAndTime,
geCrntPMOPRAvgValidity PMValidity,
geCrntPMOPRAvgInitialize InitializeCmd,
geCrntPMOPTMinValue FixedX10,
geCrntPMOPTMinTimeStamp DateAndTime,
geCrntPMOPTMinValidity PMValidity,
geCrntPMOPTMinInitialize InitializeCmd,
geCrntPMOPTMaxValue FixedX10,
geCrntPMOPTMaxTimeStamp DateAndTime,
geCrntPMOPTMaxValidity PMValidity,
geCrntPMOPTMaxInitialize InitializeCmd,
geCrntPMOPTAvgValue FixedX10,
geCrntPMOPTAvgTimeStamp DateAndTime,
geCrntPMOPTAvgValidity PMValidity,
geCrntPMOPTAvgInitialize InitializeCmd }
geCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the GE facility targeted for
PMs is provisioned."
::= { geCrntPMEntry 1 }
geCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the GE facility targeted
for PMs is provisioned."
::= { geCrntPMEntry 2 }
geCrntPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the GE
facility targeted for PMs is provisioned."
::= { geCrntPMEntry 3 }
geCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { geCrntPMEntry 4 }
geCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the GE facility
port."
::= { geCrntPMEntry 5 }
geCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { geCrntPMEntry 6 }
geCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { geCrntPMEntry 7 }
geCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the GE facility
port."
::= { geCrntPMEntry 8 }
geCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { geCrntPMEntry 9 }
geCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { geCrntPMEntry 10 }
geCrntPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the GE facility port."
::= { geCrntPMEntry 11 }
geCrntPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { geCrntPMEntry 12 }
geCrntPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { geCrntPMEntry 13 }
geCrntPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the GE facility port."
::= { geCrntPMEntry 14 }
geCrntPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { geCrntPMEntry 15 }
geCrntPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { geCrntPMEntry 16 }
geCrntPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the GE facility port."
::= { geCrntPMEntry 17 }
geCrntPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { geCrntPMEntry 18 }
geCrntPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { geCrntPMEntry 19 }
geCrntPMCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Gigabit Ethernet 8B/10B coding violations."
::= { geCrntPMEntry 20 }
geCrntPMCVTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE coding violations value."
::= { geCrntPMEntry 21 }
geCrntPMCVValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE coding violations
value."
::= { geCrntPMEntry 22 }
geCrntPMESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of GE errored seconds."
::= { geCrntPMEntry 23 }
geCrntPMESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE errored seconds value."
::= { geCrntPMEntry 24 }
geCrntPMESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE errored seconds
value."
::= { geCrntPMEntry 25 }
geCrntPMSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of GE severely errored seconds."
::= { geCrntPMEntry 26 }
geCrntPMSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE severely errored seconds
value."
::= { geCrntPMEntry 27 }
geCrntPMSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE severely errored
seconds value."
::= { geCrntPMEntry 28 }
geCrntPMTFRCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total received frame count."
::= { geCrntPMEntry 29 }
geCrntPMTFRCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total received frame count
value."
::= { geCrntPMEntry 30 }
geCrntPMTFRCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total received frame
count value."
::= { geCrntPMEntry 31 }
geCrntPMTFRCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMTFRCRXValue object
to 0."
::= { geCrntPMEntry 32 }
geCrntPMTFRCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total transmitted frame count."
::= { geCrntPMEntry 33 }
geCrntPMTFRCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total transmitted frame
count value."
::= { geCrntPMEntry 34 }
geCrntPMTFRCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total transmitted
frame count value."
::= { geCrntPMEntry 35 }
geCrntPMTFRCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMTFRCTXValue object
to 0."
::= { geCrntPMEntry 36 }
geCrntPMFRDRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Gigabit Ethernet discarded frames."
::= { geCrntPMEntry 37 }
geCrntPMFRDRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE discarded frames value."
::= { geCrntPMEntry 38 }
geCrntPMFRDRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE discarded frames
value."
::= { geCrntPMEntry 39 }
geCrntPMFCSEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Gigabit Ethernet frame checksum errors."
::= { geCrntPMEntry 40 }
geCrntPMFCSETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE frame checksum errors
value."
::= { geCrntPMEntry 41 }
geCrntPMFCSEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE frame checksum
errors value."
::= { geCrntPMEntry 42 }
geCrntPMTBYCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total received byte count."
::= { geCrntPMEntry 43 }
geCrntPMTBYCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total received byte count
value."
::= { geCrntPMEntry 44 }
geCrntPMTBYCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total received byte
count value."
::= { geCrntPMEntry 45 }
geCrntPMTBYCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMTBYCRXValue object
to 0."
::= { geCrntPMEntry 46 }
geCrntPMTBYCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total transmitted byte count."
::= { geCrntPMEntry 47 }
geCrntPMTBYCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total transmitted byte count
value."
::= { geCrntPMEntry 48 }
geCrntPMTBYCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total transmitted
byte count value."
::= { geCrntPMEntry 49 }
geCrntPMTBYCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMTBYCTXValue object
to 0."
::= { geCrntPMEntry 50 }
geCrntPMBCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
the broadcast address. Note that this does not include
multicast frames."
::= { geCrntPMEntry 51 }
geCrntPMBCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the broadcast packets received
count value."
::= { geCrntPMEntry 52 }
geCrntPMBCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided broadcast packets
received count value."
::= { geCrntPMEntry 53 }
geCrntPMBCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMBCSTValue object
to 0."
::= { geCrntPMEntry 54 }
geCrntPMMCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
a multicast address. Note that this number does not include
frames directed to the broadcast address."
::= { geCrntPMEntry 55 }
geCrntPMMCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multicast packets received
count value."
::= { geCrntPMEntry 56 }
geCrntPMMCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multicast packets
received count value."
::= { geCrntPMEntry 57 }
geCrntPMMCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMMCSTValue object
to 0."
::= { geCrntPMEntry 58 }
geCrntPMSIZE64Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of 64 byte frames received (excluding framing
bits but including FCS octets)."
::= { geCrntPMEntry 59 }
geCrntPMSIZE64TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of 64-byte packets
received."
::= { geCrntPMEntry 60 }
geCrntPMSIZE64Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of 64-byte
packets packets received."
::= { geCrntPMEntry 61 }
geCrntPMSIZE64Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMSIZE64Value object
to 0."
::= { geCrntPMEntry 62 }
geCrntPMSIZE65To127Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 65 to 127 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { geCrntPMEntry 63 }
geCrntPMSIZE65To127TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 65 and
127 bytes."
::= { geCrntPMEntry 64 }
geCrntPMSIZE65To127Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 65 and 127 bytes."
::= { geCrntPMEntry 65 }
geCrntPMSIZE65To127Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMSIZE65To127Value
object to 0."
::= { geCrntPMEntry 66 }
geCrntPMSIZE128To255Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 128 to 255 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { geCrntPMEntry 67 }
geCrntPMSIZE128To255TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 128
and 255 bytes."
::= { geCrntPMEntry 68 }
geCrntPMSIZE128To255Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 128 and 255 bytes."
::= { geCrntPMEntry 69 }
geCrntPMSIZE128To255Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMSIZE128To255Value
object to 0."
::= { geCrntPMEntry 70 }
geCrntPMSIZE256To511Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 256 to 511 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { geCrntPMEntry 71 }
geCrntPMSIZE256To511TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 256
and 511 bytes."
::= { geCrntPMEntry 72 }
geCrntPMSIZE256To511Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 256 and 511 bytes."
::= { geCrntPMEntry 73 }
geCrntPMSIZE256To511Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMSIZE256To511Value
object to 0."
::= { geCrntPMEntry 74 }
geCrntPMSIZE512To1023Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 512 to 1023 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { geCrntPMEntry 75 }
geCrntPMSIZE512To1023TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 512
and 1023 bytes."
::= { geCrntPMEntry 76 }
geCrntPMSIZE512To1023Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 512 and 1023 bytes."
::= { geCrntPMEntry 77 }
geCrntPMSIZE512To1023Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMSIZE512To1023Value
object to 0."
::= { geCrntPMEntry 78 }
geCrntPMSIZE1024To1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 1024 to 1518
bytes inclusive in length (excluding framing bits but
including FCS octets)."
::= { geCrntPMEntry 79 }
geCrntPMSIZE1024To1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 1024
and 1518 bytes."
::= { geCrntPMEntry 80 }
geCrntPMSIZE1024To1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 1024 and 1518 bytes."
::= { geCrntPMEntry 81 }
geCrntPMSIZE1024To1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
geCrntPMSIZE1024To1518Value object to 0."
::= { geCrntPMEntry 82 }
geCrntPMSIZEOver1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are greater than or
equal to 1519 bytes in length (excluding framing bits but
including FCS octets)."
::= { geCrntPMEntry 83 }
geCrntPMSIZEOver1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets over 1518
bytes."
::= { geCrntPMEntry 84 }
geCrntPMSIZEOver1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets over
1518 bytes."
::= { geCrntPMEntry 85 }
geCrntPMSIZEOver1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMSIZEOver1518Value
object to 0."
::= { geCrntPMEntry 86 }
geCrntPMTPFCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total received pause frame count."
::= { geCrntPMEntry 87 }
geCrntPMTPFCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total received pause frame
count value."
::= { geCrntPMEntry 88 }
geCrntPMTPFCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total received pause
frame count value."
::= { geCrntPMEntry 89 }
geCrntPMTPFCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMTPFCRXValue object
to 0."
::= { geCrntPMEntry 90 }
geCrntPMTPFCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total transmitted pause frame count."
::= { geCrntPMEntry 91 }
geCrntPMTPFCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total transmitted pause
frame count value."
::= { geCrntPMEntry 92 }
geCrntPMTPFCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total transmitted
pause frame count value."
::= { geCrntPMEntry 93 }
geCrntPMTPFCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMTPFCTXValue object
to 0."
::= { geCrntPMEntry 94 }
geCrntPMUSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets long (excluding framing bits, but including FCS octets)
and were otherwise well formed."
::= { geCrntPMEntry 95 }
geCrntPMUSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of undersized packets."
::= { geCrntPMEntry 96 }
geCrntPMUSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of undersized
packets."
::= { geCrntPMEntry 97 }
geCrntPMOSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were longer than 9600
octets (excluding framing bits, but including FCS octets) and
were otherwise well formed."
::= { geCrntPMEntry 98 }
geCrntPMOSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of oversized packets."
::= { geCrntPMEntry 99 }
geCrntPMOSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of oversized
packets."
::= { geCrntPMEntry 100 }
geCrntPMFRGTValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets in length (excluding framing bits but including FCS
octets) and had either a bad Frame Check Sequence (FCS) with
an integral number of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error)."
::= { geCrntPMEntry 101 }
geCrntPMFRGTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of received packet
fragments."
::= { geCrntPMEntry 102 }
geCrntPMFRGTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of received
packet fragments."
::= { geCrntPMEntry 103 }
geCrntPMJABRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were longer than
14336 9600 octets (excluding framing bits, but including FCS
octets), and had either a bad Frame Check Sequence (FCS) with
an integral number of octets (FCS Error) or a bad FCS with
non-integral number of octets (Alignment Error)."
::= { geCrntPMEntry 104 }
geCrntPMJABRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of received jabbers."
::= { geCrntPMEntry 105 }
geCrntPMJABRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of received
jabbers."
::= { geCrntPMEntry 106 }
geCrntPMCVInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMCVValue object to
0."
::= { geCrntPMEntry 107 }
geCrntPMESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMESValue object to
0."
::= { geCrntPMEntry 108 }
geCrntPMSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMSESValue object to
0."
::= { geCrntPMEntry 109 }
geCrntPMFCSEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMFCSEValue object
to 0."
::= { geCrntPMEntry 110 }
geCrntPMFRDRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMFRDRValue object
to 0."
::= { geCrntPMEntry 111 }
geCrntPMUSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMUSIZEValue object
to 0."
::= { geCrntPMEntry 112 }
geCrntPMOSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMOSIZEValue object
to 0."
::= { geCrntPMEntry 113 }
geCrntPMFRGTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMFRGTValue object
to 0."
::= { geCrntPMEntry 114 }
geCrntPMJABRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMJABRValue object
to 0."
::= { geCrntPMEntry 115 }
geCrntPMUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds. This object applies
only to transciever ports provisioned for the gigabit ethernet
protocol."
::= { geCrntPMEntry 116 }
geCrntPMUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the unavailable seconds
value."
::= { geCrntPMEntry 117 }
geCrntPMUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided unavailable
seconds value."
::= { geCrntPMEntry 118 }
geCrntPMUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMUASValue
object to 0."
::= { geCrntPMEntry 119 }
geCrntPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { geCrntPMEntry 120 }
geCrntPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { geCrntPMEntry 121 }
geCrntPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { geCrntPMEntry 122 }
geCrntPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMOPRMinValue
object to 0."
::= { geCrntPMEntry 123 }
geCrntPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { geCrntPMEntry 124 }
geCrntPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { geCrntPMEntry 125 }
geCrntPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { geCrntPMEntry 126 }
geCrntPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMOPRMaxValue
object to 0."
::= { geCrntPMEntry 127 }
geCrntPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { geCrntPMEntry 128 }
geCrntPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { geCrntPMEntry 129 }
geCrntPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { geCrntPMEntry 130 }
geCrntPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMOPRAvgValue
object to 0."
::= { geCrntPMEntry 131 }
geCrntPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { geCrntPMEntry 132 }
geCrntPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { geCrntPMEntry 133 }
geCrntPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { geCrntPMEntry 134 }
geCrntPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMOPTMinValue
object to 0."
::= { geCrntPMEntry 135 }
geCrntPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { geCrntPMEntry 136 }
geCrntPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { geCrntPMEntry 137 }
geCrntPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { geCrntPMEntry 138 }
geCrntPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMOPTMaxValue
object to 0."
::= { geCrntPMEntry 139 }
geCrntPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { geCrntPMEntry 140 }
geCrntPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { geCrntPMEntry 141 }
geCrntPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { geCrntPMEntry 142 }
geCrntPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geCrntPMOPTAvgValue
object to 0."
::= { geCrntPMEntry 143 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical Gigabit Ethernet
-- Performance Monitoring statistics
--
-- A listing of historical Gigabit Ethernet PM values is contained in
-- the geHistPMTable of the BTI 7000 Series MIB. When retrieved, this
-- table provides one row for each set of historical Gigabit Ethernet
-- PM data.
--
-- The following table lists the objects in each entry of the geHistPMTable.
-----------------------------------------------------------------------
geHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF GeHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the Gigabit Ethernet facilities on the NE."
::= { performance 21 }
geHistPMEntry OBJECT-TYPE
SYNTAX GeHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Gigabit Ethernet historical
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a historical
measurement interval for a given Gigabit Ethernet facility."
INDEX { geHistPMShelfIdx,
geHistPMSlotIdx,
geHistPMPortIdx,
geHistPMIntervalTypeIdx,
geHistPMIntervalIdx }
::= { geHistPMTable 1 }
GeHistPMEntry ::= SEQUENCE { geHistPMShelfIdx INTEGER,
geHistPMSlotIdx INTEGER,
geHistPMPortIdx INTEGER,
geHistPMIntervalTypeIdx PMIntervalType,
geHistPMIntervalIdx INTEGER,
geHistPMOPRValue FixedX10,
geHistPMOPRTimeStamp DateAndTime,
geHistPMOPRValidity PMValidity,
geHistPMOPTValue FixedX10,
geHistPMOPTTimeStamp DateAndTime,
geHistPMOPTValidity PMValidity,
geHistPMTempValue INTEGER,
geHistPMTempTimeStamp DateAndTime,
geHistPMTempValidity PMValidity,
geHistPMSupplyVoltageValue FixedX10,
geHistPMSupplyVoltageTimeStamp DateAndTime,
geHistPMSupplyVoltageValidity PMValidity,
geHistPMLBCValue INTEGER,
geHistPMLBCTimeStamp DateAndTime,
geHistPMLBCValidity PMValidity,
geHistPMCVValue Unsigned32,
geHistPMCVTimeStamp DateAndTime,
geHistPMCVValidity PMValidity,
geHistPMESValue Unsigned32,
geHistPMESTimeStamp DateAndTime,
geHistPMESValidity PMValidity,
geHistPMSESValue Unsigned32,
geHistPMSESTimeStamp DateAndTime,
geHistPMSESValidity PMValidity,
geHistPMTFRCRXValue Unsigned64,
geHistPMTFRCRXTimeStamp DateAndTime,
geHistPMTFRCRXValidity PMValidity,
geHistPMTFRCRXInitialize InitializeCmd,
geHistPMTFRCTXValue Unsigned64,
geHistPMTFRCTXTimeStamp DateAndTime,
geHistPMTFRCTXValidity PMValidity,
geHistPMTFRCTXInitialize InitializeCmd,
geHistPMFRDRValue Unsigned32,
geHistPMFRDRTimeStamp DateAndTime,
geHistPMFRDRValidity PMValidity,
geHistPMFCSEValue Unsigned32,
geHistPMFCSETimeStamp DateAndTime,
geHistPMFCSEValidity PMValidity,
geHistPMTBYCRXValue Unsigned64,
geHistPMTBYCRXTimeStamp DateAndTime,
geHistPMTBYCRXValidity PMValidity,
geHistPMTBYCRXInitialize InitializeCmd,
geHistPMTBYCTXValue Unsigned64,
geHistPMTBYCTXTimeStamp DateAndTime,
geHistPMTBYCTXValidity PMValidity,
geHistPMTBYCTXInitialize InitializeCmd,
geHistPMBCSTValue Unsigned64,
geHistPMBCSTTimeStamp DateAndTime,
geHistPMBCSTValidity PMValidity,
geHistPMBCSTInitialize InitializeCmd,
geHistPMMCSTValue Unsigned64,
geHistPMMCSTTimeStamp DateAndTime,
geHistPMMCSTValidity PMValidity,
geHistPMMCSTInitialize InitializeCmd,
geHistPMSIZE64Value Unsigned64,
geHistPMSIZE64TimeStamp DateAndTime,
geHistPMSIZE64Validity PMValidity,
geHistPMSIZE64Initialize InitializeCmd,
geHistPMSIZE65To127Value Unsigned64,
geHistPMSIZE65To127TimeStamp DateAndTime,
geHistPMSIZE65To127Validity PMValidity,
geHistPMSIZE65To127Initialize InitializeCmd,
geHistPMSIZE128To255Value Unsigned64,
geHistPMSIZE128To255TimeStamp DateAndTime,
geHistPMSIZE128To255Validity PMValidity,
geHistPMSIZE128To255Initialize InitializeCmd,
geHistPMSIZE256To511Value Unsigned64,
geHistPMSIZE256To511TimeStamp DateAndTime,
geHistPMSIZE256To511Validity PMValidity,
geHistPMSIZE256To511Initialize InitializeCmd,
geHistPMSIZE512To1023Value Unsigned64,
geHistPMSIZE512To1023TimeStamp DateAndTime,
geHistPMSIZE512To1023Validity PMValidity,
geHistPMSIZE512To1023Initialize InitializeCmd,
geHistPMSIZE1024To1518Value Unsigned64,
geHistPMSIZE1024To1518TimeStamp DateAndTime,
geHistPMSIZE1024To1518Validity PMValidity,
geHistPMSIZE1024To1518Initialize InitializeCmd,
geHistPMSIZEOver1518Value Unsigned64,
geHistPMSIZEOver1518TimeStamp DateAndTime,
geHistPMSIZEOver1518Validity PMValidity,
geHistPMSIZEOver1518Initialize InitializeCmd,
geHistPMTPFCRXValue Unsigned64,
geHistPMTPFCRXTimeStamp DateAndTime,
geHistPMTPFCRXValidity PMValidity,
geHistPMTPFCRXInitialize InitializeCmd,
geHistPMTPFCTXValue Unsigned64,
geHistPMTPFCTXTimeStamp DateAndTime,
geHistPMTPFCTXValidity PMValidity,
geHistPMTPFCTXInitialize InitializeCmd,
geHistPMUSIZEValue Unsigned32,
geHistPMUSIZETimeStamp DateAndTime,
geHistPMUSIZEValidity PMValidity,
geHistPMOSIZEValue Unsigned32,
geHistPMOSIZETimeStamp DateAndTime,
geHistPMOSIZEValidity PMValidity,
geHistPMFRGTValue Unsigned32,
geHistPMFRGTTimeStamp DateAndTime,
geHistPMFRGTValidity PMValidity,
geHistPMJABRValue Unsigned32,
geHistPMJABRTimeStamp DateAndTime,
geHistPMJABRValidity PMValidity,
geHistPMCVInitialize InitializeCmd,
geHistPMESInitialize InitializeCmd,
geHistPMSESInitialize InitializeCmd,
geHistPMFCSEInitialize InitializeCmd,
geHistPMFRDRInitialize InitializeCmd,
geHistPMUSIZEInitialize InitializeCmd,
geHistPMOSIZEInitialize InitializeCmd,
geHistPMFRGTInitialize InitializeCmd,
geHistPMJABRInitialize InitializeCmd,
geHistPMUASValue Unsigned32,
geHistPMUASTimeStamp DateAndTime,
geHistPMUASValidity PMValidity,
geHistPMUASInitialize InitializeCmd,
geHistPMOPRMinValue FixedX10,
geHistPMOPRMinTimeStamp DateAndTime,
geHistPMOPRMinValidity PMValidity,
geHistPMOPRMinInitialize InitializeCmd,
geHistPMOPRMaxValue FixedX10,
geHistPMOPRMaxTimeStamp DateAndTime,
geHistPMOPRMaxValidity PMValidity,
geHistPMOPRMaxInitialize InitializeCmd,
geHistPMOPRAvgValue FixedX10,
geHistPMOPRAvgTimeStamp DateAndTime,
geHistPMOPRAvgValidity PMValidity,
geHistPMOPRAvgInitialize InitializeCmd,
geHistPMOPTMinValue FixedX10,
geHistPMOPTMinTimeStamp DateAndTime,
geHistPMOPTMinValidity PMValidity,
geHistPMOPTMinInitialize InitializeCmd,
geHistPMOPTMaxValue FixedX10,
geHistPMOPTMaxTimeStamp DateAndTime,
geHistPMOPTMaxValidity PMValidity,
geHistPMOPTMaxInitialize InitializeCmd,
geHistPMOPTAvgValue FixedX10,
geHistPMOPTAvgTimeStamp DateAndTime,
geHistPMOPTAvgValidity PMValidity,
geHistPMOPTAvgInitialize InitializeCmd}
geHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the GE facility targeted for
PMs is provisioned."
::= { geHistPMEntry 1 }
geHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the GE facility targeted
for PMs is provisioned."
::= { geHistPMEntry 2 }
geHistPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the GE
facility targeted for PMs is provisioned."
::= { geHistPMEntry 3 }
geHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { geHistPMEntry 4 }
geHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { geHistPMEntry 5 }
geHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the GE facility
port."
::= { geHistPMEntry 6 }
geHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { geHistPMEntry 7 }
geHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { geHistPMEntry 8 }
geHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the GE facility
port."
::= { geHistPMEntry 9 }
geHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { geHistPMEntry 10 }
geHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { geHistPMEntry 11 }
geHistPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the GE facility port."
::= { geHistPMEntry 12 }
geHistPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { geHistPMEntry 13 }
geHistPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { geHistPMEntry 14 }
geHistPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the GE facility port."
::= { geHistPMEntry 15 }
geHistPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { geHistPMEntry 16 }
geHistPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { geHistPMEntry 17 }
geHistPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the GE facility port."
::= { geHistPMEntry 18 }
geHistPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { geHistPMEntry 19 }
geHistPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { geHistPMEntry 20 }
geHistPMCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Gigabit Ethernet 8B/10B coding violations."
::= { geHistPMEntry 21 }
geHistPMCVTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE coding violations value."
::= { geHistPMEntry 22 }
geHistPMCVValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE coding violations
value."
::= { geHistPMEntry 23 }
geHistPMESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of GE errored seconds."
::= { geHistPMEntry 24 }
geHistPMESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE errored seconds value."
::= { geHistPMEntry 25 }
geHistPMESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE errored seconds
value."
::= { geHistPMEntry 26 }
geHistPMSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of GE severely errored seconds."
::= { geHistPMEntry 27 }
geHistPMSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE severely errored seconds
value."
::= { geHistPMEntry 28 }
geHistPMSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE severely errored
seconds value."
::= { geHistPMEntry 29 }
geHistPMTFRCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total received byte count."
::= { geHistPMEntry 30 }
geHistPMTFRCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total received byte count
value."
::= { geHistPMEntry 31 }
geHistPMTFRCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total received byte
count value."
::= { geHistPMEntry 32 }
geHistPMTFRCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMTBYCRXValue object
to 0."
::= { geHistPMEntry 33 }
geHistPMTFRCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total transmitted frame count."
::= { geHistPMEntry 34 }
geHistPMTFRCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total transmitted frame
count value."
::= { geHistPMEntry 35 }
geHistPMTFRCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total transmitted
frame count value."
::= { geHistPMEntry 36 }
geHistPMTFRCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMTFRCTXValue object
to 0."
::= { geHistPMEntry 37 }
geHistPMFRDRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Gigabit Ethernet discarded frames."
::= { geHistPMEntry 38 }
geHistPMFRDRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE discarded frames value."
::= { geHistPMEntry 39 }
geHistPMFRDRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE discarded frames
value."
::= { geHistPMEntry 40 }
geHistPMFCSEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Gigabit Ethernet frame checksum errors."
::= { geHistPMEntry 41 }
geHistPMFCSETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE frame checksum errors
value."
::= { geHistPMEntry 42 }
geHistPMFCSEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE frame checksum
errors value."
::= { geHistPMEntry 43 }
geHistPMTBYCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total received byte count."
::= { geHistPMEntry 44 }
geHistPMTBYCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total received byte count
value."
::= { geHistPMEntry 45 }
geHistPMTBYCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total received byte
count value."
::= { geHistPMEntry 46 }
geHistPMTBYCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMTBYCRXValue object
to 0."
::= { geHistPMEntry 47 }
geHistPMTBYCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total transmitted byte count."
::= { geHistPMEntry 48 }
geHistPMTBYCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total transmitted byte count
value."
::= { geHistPMEntry 49 }
geHistPMTBYCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total transmitted
byte count value."
::= { geHistPMEntry 50 }
geHistPMTBYCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMTBYCTXValue object
to 0."
::= { geHistPMEntry 51 }
geHistPMBCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
the broadcast address. Note that this does not include
multicast frames."
::= { geHistPMEntry 52 }
geHistPMBCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the broadcast packets received
count value."
::= { geHistPMEntry 53 }
geHistPMBCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided broadcast packets
received count value."
::= { geHistPMEntry 54 }
geHistPMBCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMBCSTValue object
to 0."
::= { geHistPMEntry 55 }
geHistPMMCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
a multicast address. Note that this number does not include
frames directed to the broadcast address."
::= { geHistPMEntry 56 }
geHistPMMCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multicast packets received
count value."
::= { geHistPMEntry 57 }
geHistPMMCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multicast packets
received count value."
::= { geHistPMEntry 58 }
geHistPMMCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMMCSTValue object
to 0."
::= { geHistPMEntry 59 }
geHistPMSIZE64Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of 64 byte frames received (excluding framing
bits but including FCS octets)."
::= { geHistPMEntry 60 }
geHistPMSIZE64TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of 64-byte packets
received."
::= { geHistPMEntry 61 }
geHistPMSIZE64Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of 64-byte
packets packets received."
::= { geHistPMEntry 62 }
geHistPMSIZE64Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMSIZE64Value object
to 0."
::= { geHistPMEntry 63 }
geHistPMSIZE65To127Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 65 to 127 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { geHistPMEntry 64 }
geHistPMSIZE65To127TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 65 and
127 bytes."
::= { geHistPMEntry 65 }
geHistPMSIZE65To127Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 65 and 127 bytes."
::= { geHistPMEntry 66 }
geHistPMSIZE65To127Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMSIZE65To127Value
object to 0."
::= { geHistPMEntry 67 }
geHistPMSIZE128To255Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 128 to 255 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { geHistPMEntry 68 }
geHistPMSIZE128To255TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 128
and 255 bytes."
::= { geHistPMEntry 69 }
geHistPMSIZE128To255Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 128 and 255 bytes."
::= { geHistPMEntry 70 }
geHistPMSIZE128To255Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMSIZE128To255Value
object to 0."
::= { geHistPMEntry 71 }
geHistPMSIZE256To511Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 256 to 511 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { geHistPMEntry 72 }
geHistPMSIZE256To511TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 256
and 511 bytes."
::= { geHistPMEntry 73 }
geHistPMSIZE256To511Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 256 and 511 bytes."
::= { geHistPMEntry 74 }
geHistPMSIZE256To511Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMSIZE256To511Value
object to 0."
::= { geHistPMEntry 75 }
geHistPMSIZE512To1023Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 512 to 1023 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { geHistPMEntry 76 }
geHistPMSIZE512To1023TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 512
and 1023 bytes."
::= { geHistPMEntry 77 }
geHistPMSIZE512To1023Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 512 and 1023 bytes."
::= { geHistPMEntry 78 }
geHistPMSIZE512To1023Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMSIZE512To1023Value
object to 0."
::= { geHistPMEntry 79 }
geHistPMSIZE1024To1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 1024 to 1518
bytes inclusive in length (excluding framing bits but
including FCS octets)."
::= { geHistPMEntry 80 }
geHistPMSIZE1024To1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 1024
and 1518 bytes."
::= { geHistPMEntry 81 }
geHistPMSIZE1024To1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 1024 and 1518 bytes."
::= { geHistPMEntry 82 }
geHistPMSIZE1024To1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
geHistPMSIZE1024To1518Value object to 0."
::= { geHistPMEntry 83 }
geHistPMSIZEOver1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are greater than or
equal to 1519 bytes in length (excluding framing bits but
including FCS octets)."
::= { geHistPMEntry 84 }
geHistPMSIZEOver1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets over 1518
bytes."
::= { geHistPMEntry 85 }
geHistPMSIZEOver1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets over
1518 bytes."
::= { geHistPMEntry 86 }
geHistPMSIZEOver1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMSIZEOver1518Value
object to 0."
::= { geHistPMEntry 87 }
geHistPMTPFCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total received pause frame count."
::= { geHistPMEntry 88 }
geHistPMTPFCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total received pause frame
count value."
::= { geHistPMEntry 89 }
geHistPMTPFCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total received pause
frame count value."
::= { geHistPMEntry 90 }
geHistPMTPFCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMTPFCRXValue object
to 0."
::= { geHistPMEntry 91 }
geHistPMTPFCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Gigabit Ethernet total transmitted pause frame count."
::= { geHistPMEntry 92 }
geHistPMTPFCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the GE total transmitted pause
frame count value."
::= { geHistPMEntry 93 }
geHistPMTPFCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided GE total transmitted
pause frame count value."
::= { geHistPMEntry 94 }
geHistPMTPFCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMTPFCTXValue object
to 0."
::= { geHistPMEntry 95 }
geHistPMUSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets long (excluding framing bits, but including FCS octets)
and were otherwise well formed."
::= { geHistPMEntry 96 }
geHistPMUSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of undersized packets."
::= { geHistPMEntry 97 }
geHistPMUSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of undersized
packets."
::= { geHistPMEntry 98 }
geHistPMOSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were longer than 9600
octets (excluding framing bits, but including FCS octets) and
were otherwise well formed."
::= { geHistPMEntry 99 }
geHistPMOSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of oversized packets."
::= { geHistPMEntry 100 }
geHistPMOSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of oversized
packets."
::= { geHistPMEntry 101 }
geHistPMFRGTValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets in length (excluding framing bits but including FCS
octets) and had either a bad Frame Check Sequence (FCS) with
an integral number of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error)."
::= { geHistPMEntry 102 }
geHistPMFRGTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of received packet
fragments."
::= { geHistPMEntry 103 }
geHistPMFRGTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of received
packet fragments."
::= { geHistPMEntry 104 }
geHistPMJABRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were longer than
14336 9600 octets (excluding framing bits, but including FCS
octets), and had either a bad Frame Check Sequence (FCS) with
an integral number of octets (FCS Error) or a bad FCS with
non-integral number of octets (Alignment Error)."
::= { geHistPMEntry 105 }
geHistPMJABRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of received jabbers."
::= { geHistPMEntry 106 }
geHistPMJABRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of received
jabbers."
::= { geHistPMEntry 107 }
geHistPMCVInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMCVValue object to
0."
::= { geHistPMEntry 108 }
geHistPMESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMESValue object to
0."
::= { geHistPMEntry 109 }
geHistPMSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMSESValue object to
0."
::= { geHistPMEntry 110 }
geHistPMFCSEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMFCSEValue object
to 0."
::= { geHistPMEntry 111 }
geHistPMFRDRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMFRDRValue object
to 0."
::= { geHistPMEntry 112 }
geHistPMUSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMUSIZEValue object
to 0."
::= { geHistPMEntry 113 }
geHistPMOSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMOSIZEValue object
to 0."
::= { geHistPMEntry 114 }
geHistPMFRGTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMFRGTValue object
to 0."
::= { geHistPMEntry 115 }
geHistPMJABRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMJABRValue object
to 0."
::= { geHistPMEntry 116 }
geHistPMUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds. This object applies
only to transciever ports provisioned for the gigabit ethernet
protocol."
::= { geHistPMEntry 117 }
geHistPMUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the unavailable seconds
value."
::= { geHistPMEntry 118 }
geHistPMUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided unavailable
seconds value."
::= { geHistPMEntry 119 }
geHistPMUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMUASValue
object to 0."
::= { geHistPMEntry 120 }
geHistPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { geHistPMEntry 121 }
geHistPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { geHistPMEntry 122 }
geHistPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { geHistPMEntry 123 }
geHistPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMOPRMinValue
object to 0."
::= { geHistPMEntry 124 }
geHistPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { geHistPMEntry 125 }
geHistPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { geHistPMEntry 126 }
geHistPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { geHistPMEntry 127 }
geHistPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMOPRMaxValue
object to 0."
::= { geHistPMEntry 128 }
geHistPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { geHistPMEntry 129 }
geHistPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { geHistPMEntry 130 }
geHistPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { geHistPMEntry 131 }
geHistPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMOPRAvgValue
object to 0."
::= { geHistPMEntry 132 }
geHistPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { geHistPMEntry 133 }
geHistPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { geHistPMEntry 134 }
geHistPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { geHistPMEntry 135 }
geHistPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMOPTMinValue
object to 0."
::= { geHistPMEntry 136 }
geHistPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { geHistPMEntry 137 }
geHistPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { geHistPMEntry 138 }
geHistPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { geHistPMEntry 139 }
geHistPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMOPTMaxValue
object to 0."
::= { geHistPMEntry 140 }
geHistPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { geHistPMEntry 141 }
geHistPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { geHistPMEntry 142 }
geHistPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { geHistPMEntry 143 }
geHistPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the geHistPMOPTAvgValue
object to 0."
::= { geHistPMEntry 144 }
-----------------------------------------------------------------------
-- Objects used to manage Gigabit Ethernet Performance
-- Monitoring Threshold Levels
--
-- A listing of Gigabit Ethernet PM threshold levels is contained in
-- the gePMThresholdTable of the BTI-7000-MIB. When retrieved, this
-- table provides one row for each set of Gigabit Ethernet PM threshold
-- data.
--
-- The following table lists the objects in each entry of the
-- gePMThresholdTable.
-----------------------------------------------------------------------
gePMThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF GePMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of threshold levels for performance monitoring counter
values on Gigabit Ethernet facilities, that are used in the
generation of threshold crossing alerts."
::= { performance 22 }
gePMThresholdEntry OBJECT-TYPE
SYNTAX GePMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Gigabit Ethernet performance
monitoring threshold table. Each row of this table contains a
set of PM thresholds for a given interval type that applies to
an individual GE facility."
INDEX { gePMThresholdShelfIdx,
gePMThresholdSlotIdx,
gePMThresholdPortIdx,
gePMThresholdIntervalTypeIdx }
::= { gePMThresholdTable 1 }
GePMThresholdEntry ::= SEQUENCE { gePMThresholdShelfIdx INTEGER,
gePMThresholdSlotIdx INTEGER,
gePMThresholdPortIdx INTEGER,
gePMThresholdIntervalTypeIdx PMIntervalType,
gePMThresholdCVValue Unsigned32,
gePMThresholdESValue Unsigned32,
gePMThresholdSESValue Unsigned32,
gePMThresholdFRDRValue Unsigned32,
gePMThresholdFCSEValue Unsigned32,
gePMThresholdUSIZEValue Unsigned32,
gePMThresholdOSIZEValue Unsigned32,
gePMThresholdFRGTValue Unsigned32,
gePMThresholdJABRValue Unsigned32,
gePMThresholdUASValue Unsigned32}
gePMThresholdShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The shelf number on which the Gigabit Ethernet facility
targeted for PM thresholds is provisioned."
::= { gePMThresholdEntry 1 }
gePMThresholdSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The slot number on which the Gigabit Ethernet facility
targeted for PM thresholds is provisioned."
::= { gePMThresholdEntry 2 }
gePMThresholdPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
Gigabit Ethernet facility targeted for PM thresholds is
provisioned."
::= { gePMThresholdEntry 3 }
gePMThresholdIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length. Thresholds
are supported for the 15-minute and 1-day PM bins only."
::= { gePMThresholdEntry 4 }
gePMThresholdCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Gigabit Ethernet 8B/10B coding
violations."
::= { gePMThresholdEntry 5 }
gePMThresholdESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Gigabit Ethernet errored
seconds."
::= { gePMThresholdEntry 6 }
gePMThresholdSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Gigabit Ethernet severely
errored seconds."
::= { gePMThresholdEntry 7 }
gePMThresholdFRDRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Gigabit Ethernet discarded
frames."
::= { gePMThresholdEntry 8 }
gePMThresholdFCSEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Gigabit Ethernet frame check
sum errors."
::= { gePMThresholdEntry 9 }
gePMThresholdUSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Gigabit Ethernet undersized
frames."
::= { gePMThresholdEntry 10 }
gePMThresholdOSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Gigabit Ethernet oversized
frames."
::= { gePMThresholdEntry 11 }
gePMThresholdFRGTValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Gigabit Ethernet frame
fragments."
::= { gePMThresholdEntry 12 }
gePMThresholdJABRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Gigabit Ethernet jabbers."
::= { gePMThresholdEntry 13 }
gePMThresholdUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Gigabit Ethernet unavailable seconds."
::= { gePMThresholdEntry 14 }
-----------------------------------------------------------------------
-- Objects used to retrieve current Fiber Channel
-- Performance Monitoring statistics
-----------------------------------------------------------------------
fcCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the Fiber Channel facilities on the NE."
::= { performance 23 }
fcCrntPMEntry OBJECT-TYPE
SYNTAX FcCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Fiber Channel current performance
monitoring table. Each row of this table contains a full set
of PM statistics and related data for a current measurement
interval for a given Fiber Channel facility."
INDEX { fcCrntPMShelfIdx,
fcCrntPMSlotIdx,
fcCrntPMPortIdx,
fcCrntPMIntervalTypeIdx }
::= { fcCrntPMTable 1 }
FcCrntPMEntry ::= SEQUENCE { fcCrntPMShelfIdx INTEGER,
fcCrntPMSlotIdx INTEGER,
fcCrntPMPortIdx INTEGER,
fcCrntPMIntervalTypeIdx PMIntervalType,
fcCrntPMOPRValue FixedX10,
fcCrntPMOPRTimeStamp DateAndTime,
fcCrntPMOPRValidity PMValidity,
fcCrntPMOPTValue FixedX10,
fcCrntPMOPTTimeStamp DateAndTime,
fcCrntPMOPTValidity PMValidity,
fcCrntPMTempValue INTEGER,
fcCrntPMTempTimeStamp DateAndTime,
fcCrntPMTempValidity PMValidity,
fcCrntPMSupplyVoltageValue FixedX10,
fcCrntPMSupplyVoltageTimeStamp DateAndTime,
fcCrntPMSupplyVoltageValidity PMValidity,
fcCrntPMLBCValue INTEGER,
fcCrntPMLBCTimeStamp DateAndTime,
fcCrntPMLBCValidity PMValidity,
fcCrntPMCVValue Unsigned32,
fcCrntPMCVTimeStamp DateAndTime,
fcCrntPMCVValidity PMValidity,
fcCrntPMESValue Unsigned32,
fcCrntPMESTimeStamp DateAndTime,
fcCrntPMESValidity PMValidity,
fcCrntPMSESValue Unsigned32,
fcCrntPMSESTimeStamp DateAndTime,
fcCrntPMSESValidity PMValidity,
fcCrntPMCVInitialize InitializeCmd,
fcCrntPMESInitialize InitializeCmd,
fcCrntPMSESInitialize InitializeCmd,
fcCrntPMUASValue Unsigned32,
fcCrntPMUASTimeStamp DateAndTime,
fcCrntPMUASValidity PMValidity,
fcCrntPMUASInitialize InitializeCmd,
fcCrntPMOPRMinValue FixedX10,
fcCrntPMOPRMinTimeStamp DateAndTime,
fcCrntPMOPRMinValidity PMValidity,
fcCrntPMOPRMinInitialize InitializeCmd,
fcCrntPMOPRMaxValue FixedX10,
fcCrntPMOPRMaxTimeStamp DateAndTime,
fcCrntPMOPRMaxValidity PMValidity,
fcCrntPMOPRMaxInitialize InitializeCmd,
fcCrntPMOPRAvgValue FixedX10,
fcCrntPMOPRAvgTimeStamp DateAndTime,
fcCrntPMOPRAvgValidity PMValidity,
fcCrntPMOPRAvgInitialize InitializeCmd,
fcCrntPMOPTMinValue FixedX10,
fcCrntPMOPTMinTimeStamp DateAndTime,
fcCrntPMOPTMinValidity PMValidity,
fcCrntPMOPTMinInitialize InitializeCmd,
fcCrntPMOPTMaxValue FixedX10,
fcCrntPMOPTMaxTimeStamp DateAndTime,
fcCrntPMOPTMaxValidity PMValidity,
fcCrntPMOPTMaxInitialize InitializeCmd,
fcCrntPMOPTAvgValue FixedX10,
fcCrntPMOPTAvgTimeStamp DateAndTime,
fcCrntPMOPTAvgValidity PMValidity,
fcCrntPMOPTAvgInitialize InitializeCmd }
fcCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the FC facility targeted for
PMs is provisioned."
::= { fcCrntPMEntry 1 }
fcCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the FC facility targeted
for PMs is provisioned."
::= { fcCrntPMEntry 2 }
fcCrntPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the FC
facility targeted for PMs is provisioned."
::= { fcCrntPMEntry 3 }
fcCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { fcCrntPMEntry 4 }
fcCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the FC facility
port."
::= { fcCrntPMEntry 5 }
fcCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { fcCrntPMEntry 6 }
fcCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { fcCrntPMEntry 7 }
fcCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the FC facility
port."
::= { fcCrntPMEntry 8 }
fcCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { fcCrntPMEntry 9 }
fcCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { fcCrntPMEntry 10 }
fcCrntPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the FC facility port."
::= { fcCrntPMEntry 11 }
fcCrntPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { fcCrntPMEntry 12 }
fcCrntPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { fcCrntPMEntry 13 }
fcCrntPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the FC facility port."
::= { fcCrntPMEntry 14 }
fcCrntPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { fcCrntPMEntry 15 }
fcCrntPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { fcCrntPMEntry 16 }
fcCrntPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the FC facility port."
::= { fcCrntPMEntry 17 }
fcCrntPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { fcCrntPMEntry 18 }
fcCrntPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { fcCrntPMEntry 19 }
fcCrntPMCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Fiber Channel coding violations."
::= { fcCrntPMEntry 20 }
fcCrntPMCVTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the FC coding violations value."
::= { fcCrntPMEntry 21 }
fcCrntPMCVValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided FC coding violations
value."
::= { fcCrntPMEntry 22 }
fcCrntPMESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of FC errored seconds."
::= { fcCrntPMEntry 23 }
fcCrntPMESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the FC errored seconds value."
::= { fcCrntPMEntry 24 }
fcCrntPMESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided FC errored seconds
value."
::= { fcCrntPMEntry 25 }
fcCrntPMSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of FC severely errored seconds."
::= { fcCrntPMEntry 26 }
fcCrntPMSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the FC severely errored seconds
value."
::= { fcCrntPMEntry 27 }
fcCrntPMSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided FC severely errored
seconds value."
::= { fcCrntPMEntry 28 }
fcCrntPMCVInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcCrntPMCVValue object to
0."
::= { fcCrntPMEntry 29 }
fcCrntPMESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcCrntPMESValue object to
0."
::= { fcCrntPMEntry 30 }
fcCrntPMSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcCrntPMSESValue object to
0."
::= { fcCrntPMEntry 31 }
fcCrntPMUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds. This object applies
only to transciever ports provisioned for the fiber
channel protocol."
::= { fcCrntPMEntry 32 }
fcCrntPMUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the unavailable seconds
value."
::= { fcCrntPMEntry 33 }
fcCrntPMUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided unavailable
seconds value."
::= { fcCrntPMEntry 34 }
fcCrntPMUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcCrntPMUASValue
object to 0."
::= { fcCrntPMEntry 35 }
fcCrntPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { fcCrntPMEntry 36 }
fcCrntPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { fcCrntPMEntry 37 }
fcCrntPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { fcCrntPMEntry 38 }
fcCrntPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcCrntPMOPRMinValue
object to 0."
::= { fcCrntPMEntry 39 }
fcCrntPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { fcCrntPMEntry 40 }
fcCrntPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { fcCrntPMEntry 41 }
fcCrntPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { fcCrntPMEntry 42 }
fcCrntPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcCrntPMOPRMaxValue
object to 0."
::= { fcCrntPMEntry 43 }
fcCrntPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { fcCrntPMEntry 44 }
fcCrntPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { fcCrntPMEntry 45 }
fcCrntPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { fcCrntPMEntry 46 }
fcCrntPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcCrntPMOPRAvgValue
object to 0."
::= { fcCrntPMEntry 47 }
fcCrntPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { fcCrntPMEntry 48 }
fcCrntPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { fcCrntPMEntry 49 }
fcCrntPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { fcCrntPMEntry 50 }
fcCrntPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcCrntPMOPTMinValue
object to 0."
::= { fcCrntPMEntry 51 }
fcCrntPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { fcCrntPMEntry 52 }
fcCrntPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { fcCrntPMEntry 53 }
fcCrntPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { fcCrntPMEntry 54 }
fcCrntPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcCrntPMOPTMaxValue
object to 0."
::= { fcCrntPMEntry 55 }
fcCrntPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { fcCrntPMEntry 56 }
fcCrntPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { fcCrntPMEntry 57 }
fcCrntPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { fcCrntPMEntry 58 }
fcCrntPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcCrntPMOPTAvgValue
object to 0."
::= { fcCrntPMEntry 59 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical Fiber Channel
-- Performance Monitoring statistics
-----------------------------------------------------------------------
fcHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the Fiber Channel facilities on the NE."
::= { performance 24 }
fcHistPMEntry OBJECT-TYPE
SYNTAX FcHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Fiber Channel historical
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a historical
measurement interval for a given Fiber Channel facility."
INDEX { fcHistPMShelfIdx,
fcHistPMSlotIdx,
fcHistPMPortIdx,
fcHistPMIntervalTypeIdx,
fcHistPMIntervalIdx }
::= { fcHistPMTable 1 }
FcHistPMEntry ::= SEQUENCE { fcHistPMShelfIdx INTEGER,
fcHistPMSlotIdx INTEGER,
fcHistPMPortIdx INTEGER,
fcHistPMIntervalTypeIdx PMIntervalType,
fcHistPMIntervalIdx INTEGER,
fcHistPMOPRValue FixedX10,
fcHistPMOPRTimeStamp DateAndTime,
fcHistPMOPRValidity PMValidity,
fcHistPMOPTValue FixedX10,
fcHistPMOPTTimeStamp DateAndTime,
fcHistPMOPTValidity PMValidity,
fcHistPMTempValue INTEGER,
fcHistPMTempTimeStamp DateAndTime,
fcHistPMTempValidity PMValidity,
fcHistPMSupplyVoltageValue FixedX10,
fcHistPMSupplyVoltageTimeStamp DateAndTime,
fcHistPMSupplyVoltageValidity PMValidity,
fcHistPMLBCValue INTEGER,
fcHistPMLBCTimeStamp DateAndTime,
fcHistPMLBCValidity PMValidity,
fcHistPMCVValue Unsigned32,
fcHistPMCVTimeStamp DateAndTime,
fcHistPMCVValidity PMValidity,
fcHistPMESValue Unsigned32,
fcHistPMESTimeStamp DateAndTime,
fcHistPMESValidity PMValidity,
fcHistPMSESValue Unsigned32,
fcHistPMSESTimeStamp DateAndTime,
fcHistPMSESValidity PMValidity,
fcHistPMCVInitialize InitializeCmd,
fcHistPMESInitialize InitializeCmd,
fcHistPMSESInitialize InitializeCmd,
fcHistPMUASValue Unsigned32,
fcHistPMUASTimeStamp DateAndTime,
fcHistPMUASValidity PMValidity,
fcHistPMUASInitialize InitializeCmd,
fcHistPMOPRMinValue FixedX10,
fcHistPMOPRMinTimeStamp DateAndTime,
fcHistPMOPRMinValidity PMValidity,
fcHistPMOPRMinInitialize InitializeCmd,
fcHistPMOPRMaxValue FixedX10,
fcHistPMOPRMaxTimeStamp DateAndTime,
fcHistPMOPRMaxValidity PMValidity,
fcHistPMOPRMaxInitialize InitializeCmd,
fcHistPMOPRAvgValue FixedX10,
fcHistPMOPRAvgTimeStamp DateAndTime,
fcHistPMOPRAvgValidity PMValidity,
fcHistPMOPRAvgInitialize InitializeCmd,
fcHistPMOPTMinValue FixedX10,
fcHistPMOPTMinTimeStamp DateAndTime,
fcHistPMOPTMinValidity PMValidity,
fcHistPMOPTMinInitialize InitializeCmd,
fcHistPMOPTMaxValue FixedX10,
fcHistPMOPTMaxTimeStamp DateAndTime,
fcHistPMOPTMaxValidity PMValidity,
fcHistPMOPTMaxInitialize InitializeCmd,
fcHistPMOPTAvgValue FixedX10,
fcHistPMOPTAvgTimeStamp DateAndTime,
fcHistPMOPTAvgValidity PMValidity,
fcHistPMOPTAvgInitialize InitializeCmd }
fcHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the FC facility targeted for
PMs is provisioned."
::= { fcHistPMEntry 1 }
fcHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the FC facility targeted
for PMs is provisioned."
::= { fcHistPMEntry 2 }
fcHistPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the FC
facility targeted for PMs is provisioned."
::= { fcHistPMEntry 3 }
fcHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { fcHistPMEntry 4 }
fcHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { fcHistPMEntry 5 }
fcHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the FC facility
port."
::= { fcHistPMEntry 6 }
fcHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { fcHistPMEntry 7 }
fcHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { fcHistPMEntry 8 }
fcHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the FC facility
port."
::= { fcHistPMEntry 9 }
fcHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { fcHistPMEntry 10 }
fcHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { fcHistPMEntry 11 }
fcHistPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the FC facility port."
::= { fcHistPMEntry 12 }
fcHistPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { fcHistPMEntry 13 }
fcHistPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { fcHistPMEntry 14 }
fcHistPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the FC facility port."
::= { fcHistPMEntry 15 }
fcHistPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { fcHistPMEntry 16 }
fcHistPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { fcHistPMEntry 17 }
fcHistPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the FC facility port."
::= { fcHistPMEntry 18 }
fcHistPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { fcHistPMEntry 19 }
fcHistPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { fcHistPMEntry 20 }
fcHistPMCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Fiber Channel coding violations."
::= { fcHistPMEntry 21 }
fcHistPMCVTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the FC coding violations value."
::= { fcHistPMEntry 22 }
fcHistPMCVValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided FC coding violations
value."
::= { fcHistPMEntry 23 }
fcHistPMESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of FC errored seconds."
::= { fcHistPMEntry 24 }
fcHistPMESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the FC errored seconds value."
::= { fcHistPMEntry 25 }
fcHistPMESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided FC errored seconds
value."
::= { fcHistPMEntry 26 }
fcHistPMSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of FC severely errored seconds."
::= { fcHistPMEntry 27 }
fcHistPMSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the FC severely errored seconds
value."
::= { fcHistPMEntry 28 }
fcHistPMSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided FC severely errored
seconds value."
::= { fcHistPMEntry 29 }
fcHistPMCVInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcHistPMCVValue object to
0."
::= { fcHistPMEntry 30 }
fcHistPMESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcHistPMESValue object to
0."
::= { fcHistPMEntry 31 }
fcHistPMSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcHistPMSESValue object to
0."
::= { fcHistPMEntry 32 }
fcHistPMUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds. This object applies
only to transciever ports provisioned for the fiber
channel protocol."
::= { fcHistPMEntry 33 }
fcHistPMUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the unavailable seconds
value."
::= { fcHistPMEntry 34 }
fcHistPMUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided unavailable
seconds value."
::= { fcHistPMEntry 35 }
fcHistPMUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcHistPMUASValue
object to 0."
::= { fcHistPMEntry 36 }
fcHistPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { fcHistPMEntry 37 }
fcHistPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { fcHistPMEntry 38 }
fcHistPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { fcHistPMEntry 39 }
fcHistPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcHistPMOPRMinValue
object to 0."
::= { fcHistPMEntry 40 }
fcHistPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { fcHistPMEntry 41 }
fcHistPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { fcHistPMEntry 42 }
fcHistPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { fcHistPMEntry 43 }
fcHistPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcHistPMOPRMaxValue
object to 0."
::= { fcHistPMEntry 44 }
fcHistPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { fcHistPMEntry 45 }
fcHistPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { fcHistPMEntry 46 }
fcHistPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { fcHistPMEntry 47 }
fcHistPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcHistPMOPRAvgValue
object to 0."
::= { fcHistPMEntry 48 }
fcHistPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { fcHistPMEntry 49 }
fcHistPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { fcHistPMEntry 50 }
fcHistPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { fcHistPMEntry 51 }
fcHistPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcHistPMOPTMinValue
object to 0."
::= { fcHistPMEntry 52 }
fcHistPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { fcHistPMEntry 53 }
fcHistPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { fcHistPMEntry 54 }
fcHistPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { fcHistPMEntry 55 }
fcHistPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcHistPMOPTMaxValue
object to 0."
::= { fcHistPMEntry 56 }
fcHistPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { fcHistPMEntry 57 }
fcHistPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { fcHistPMEntry 58 }
fcHistPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { fcHistPMEntry 59 }
fcHistPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the fcHistPMOPTAvgValue
object to 0."
::= { fcHistPMEntry 60 }
-----------------------------------------------------------------------
-- Objects used to manage Fiber Channel Performance
-- Monitoring Threshold Levels
-----------------------------------------------------------------------
fcPMThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of threshold levels for performance monitoring counter
values on Fiber Channel facilities, that are used in the
generation of threshold crossing alerts."
::= { performance 25 }
fcPMThresholdEntry OBJECT-TYPE
SYNTAX FcPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Fiber Channel performance
monitoring threshold table. Each row of this table contains a
set of PM thresholds for a given interval type that applies to
an individual FC facility."
INDEX { fcPMThresholdShelfIdx,
fcPMThresholdSlotIdx,
fcPMThresholdPortIdx,
fcPMThresholdIntervalTypeIdx }
::= { fcPMThresholdTable 1 }
FcPMThresholdEntry ::= SEQUENCE { fcPMThresholdShelfIdx INTEGER,
fcPMThresholdSlotIdx INTEGER,
fcPMThresholdPortIdx INTEGER,
fcPMThresholdIntervalTypeIdx PMIntervalType,
fcPMThresholdCVValue Unsigned32,
fcPMThresholdESValue Unsigned32,
fcPMThresholdSESValue Unsigned32,
fcPMThresholdUASValue Unsigned32 }
fcPMThresholdShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The shelf number on which the Fiber Channel facility targeted
for PM thresholds is provisioned."
::= { fcPMThresholdEntry 1 }
fcPMThresholdSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The slot number on which the Fiber Channel facility targeted
for PM thresholds is provisioned."
::= { fcPMThresholdEntry 2 }
fcPMThresholdPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the Fiber
Channel facility targeted for PM thresholds is provisioned."
::= { fcPMThresholdEntry 3 }
fcPMThresholdIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length. Thresholds
are supported for the 15-minute and 1-day PM bins only."
::= { fcPMThresholdEntry 4 }
fcPMThresholdCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Fiber Channel coding
violations."
::= { fcPMThresholdEntry 5 }
fcPMThresholdESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Fiber Channel errored seconds."
::= { fcPMThresholdEntry 6 }
fcPMThresholdSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Fiber Channel severely errored
seconds."
::= { fcPMThresholdEntry 7 }
fcPMThresholdUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of Fiber Channel unavailable seconds."
::= { fcPMThresholdEntry 8 }
-----------------------------------------------------------------------
-- Objects used to retrieve current Ethernet Layer 1 Interface
-- Performance Monitoring statistics
-----------------------------------------------------------------------
ethL1IFCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthL1IFCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the Ethernet Layer 1 Interface facilities on the NE."
::= { performance 26 }
ethL1IFCrntPMEntry OBJECT-TYPE
SYNTAX EthL1IFCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Ethernet Layer 1 Interface current
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a current
measurement interval for a given Ethernet Layer 1 Interface facility."
INDEX { ethL1IFCrntPMShelfIdx,
ethL1IFCrntPMSlotIdx,
ethL1IFCrntPMPortTypeIdx,
ethL1IFCrntPMPortIdx,
ethL1IFCrntPMIntervalTypeIdx }
::= { ethL1IFCrntPMTable 1 }
EthL1IFCrntPMEntry ::= SEQUENCE { ethL1IFCrntPMShelfIdx INTEGER,
ethL1IFCrntPMSlotIdx INTEGER,
ethL1IFCrntPMPortTypeIdx PvxL1PortType,
ethL1IFCrntPMPortIdx INTEGER,
ethL1IFCrntPMIntervalTypeIdx PMIntervalType,
ethL1IFCrntPMOPRValue FixedX10,
ethL1IFCrntPMOPRTimeStamp DateAndTime,
ethL1IFCrntPMOPRValidity PMValidity,
ethL1IFCrntPMOPTValue FixedX10,
ethL1IFCrntPMOPTTimeStamp DateAndTime,
ethL1IFCrntPMOPTValidity PMValidity,
ethL1IFCrntPMTempValue INTEGER,
ethL1IFCrntPMTempTimeStamp DateAndTime,
ethL1IFCrntPMTempValidity PMValidity,
ethL1IFCrntPMSupplyVoltageValue FixedX10,
ethL1IFCrntPMSupplyVoltageTimeStamp DateAndTime,
ethL1IFCrntPMSupplyVoltageValidity PMValidity,
ethL1IFCrntPMSupplyVoltage2Value FixedX10,
ethL1IFCrntPMSupplyVoltage2TimeStamp DateAndTime,
ethL1IFCrntPMSupplyVoltage2Validity PMValidity,
ethL1IFCrntPMLBCValue INTEGER,
ethL1IFCrntPMLBCTimeStamp DateAndTime,
ethL1IFCrntPMLBCValidity PMValidity,
ethL1IFCrntPMCVValue Unsigned32,
ethL1IFCrntPMCVTimeStamp DateAndTime,
ethL1IFCrntPMCVValidity PMValidity,
ethL1IFCrntPMCVInitialize InitializeCmd,
ethL1IFCrntPMINVBLKValue Unsigned32,
ethL1IFCrntPMINVBLKTimeStamp DateAndTime,
ethL1IFCrntPMINVBLKValidity PMValidity,
ethL1IFCrntPMINVBLKInitialize InitializeCmd,
ethL1IFCrntPMESValue Unsigned32,
ethL1IFCrntPMESTimeStamp DateAndTime,
ethL1IFCrntPMESValidity PMValidity,
ethL1IFCrntPMESInitialize InitializeCmd,
ethL1IFCrntPMSESValue Unsigned32,
ethL1IFCrntPMSESTimeStamp DateAndTime,
ethL1IFCrntPMSESValidity PMValidity,
ethL1IFCrntPMSESInitialize InitializeCmd,
ethL1IFCrntPMOTUEBValue Unsigned32,
ethL1IFCrntPMOTUEBTimeStamp DateAndTime,
ethL1IFCrntPMOTUEBValidity PMValidity,
ethL1IFCrntPMOTUEBInitialize InitializeCmd,
ethL1IFCrntPMOTUBBEValue Unsigned32,
ethL1IFCrntPMOTUBBETimeStamp DateAndTime,
ethL1IFCrntPMOTUBBEValidity PMValidity,
ethL1IFCrntPMOTUBBEInitialize InitializeCmd,
ethL1IFCrntPMOTUESValue Unsigned32,
ethL1IFCrntPMOTUESTimeStamp DateAndTime,
ethL1IFCrntPMOTUESValidity PMValidity,
ethL1IFCrntPMOTUESInitialize InitializeCmd,
ethL1IFCrntPMOTUSESValue Unsigned32,
ethL1IFCrntPMOTUSESTimeStamp DateAndTime,
ethL1IFCrntPMOTUSESValidity PMValidity,
ethL1IFCrntPMOTUSESInitialize InitializeCmd,
ethL1IFCrntPMOTUOFSValue Unsigned32,
ethL1IFCrntPMOTUOFSTimeStamp DateAndTime,
ethL1IFCrntPMOTUOFSValidity PMValidity,
ethL1IFCrntPMOTUOFSInitialize InitializeCmd,
ethL1IFCrntPMNBITCRValue Unsigned32,
ethL1IFCrntPMNBITCRTimeStamp DateAndTime,
ethL1IFCrntPMNBITCRValidity PMValidity,
ethL1IFCrntPMNBITCRInitialize InitializeCmd,
ethL1IFCrntPMNBYTCRValue Unsigned32,
ethL1IFCrntPMNBYTCRTimeStamp DateAndTime,
ethL1IFCrntPMNBYTCRValidity PMValidity,
ethL1IFCrntPMNBYTCRInitialize InitializeCmd,
ethL1IFCrntPMUNCRCDWValue Unsigned32,
ethL1IFCrntPMUNCRCDWTimeStamp DateAndTime,
ethL1IFCrntPMUNCRCDWValidity PMValidity,
ethL1IFCrntPMUNCRCDWInitialize InitializeCmd,
ethL1IFCrntPMOTNBERValue DisplayString,
ethL1IFCrntPMOTNBERTimeStamp DateAndTime,
ethL1IFCrntPMOTNBERValidity PMValidity,
ethL1IFCrntPMOTNBERInitialize InitializeCmd,
ethL1IFCrntPMOTNAVGBERValue DisplayString,
ethL1IFCrntPMOTNAVGBERTimeStamp DateAndTime,
ethL1IFCrntPMOTNAVGBERValidity PMValidity,
ethL1IFCrntPMOTNAVGBERInitialize InitializeCmd,
ethL1IFCrntPMNBITCR64BitValue Unsigned64,
ethL1IFCrntPMNBITCR64BitTimeStamp DateAndTime,
ethL1IFCrntPMNBITCR64BitValidity PMValidity,
ethL1IFCrntPMNBITCR64BitInitialize InitializeCmd,
ethL1IFCrntPMNBYTCR64BitValue Unsigned64,
ethL1IFCrntPMNBYTCR64BitTimeStamp DateAndTime,
ethL1IFCrntPMNBYTCR64BitValidity PMValidity,
ethL1IFCrntPMNBYTCR64BitInitialize InitializeCmd,
ethL1IFCrntPMUASValue Unsigned32,
ethL1IFCrntPMUASTimeStamp DateAndTime,
ethL1IFCrntPMUASValidity PMValidity,
ethL1IFCrntPMUASInitialize InitializeCmd,
ethL1IFCrntPMOTUUASValue Unsigned32,
ethL1IFCrntPMOTUUASTimeStamp DateAndTime,
ethL1IFCrntPMOTUUASValidity PMValidity,
ethL1IFCrntPMOTUUASInitialize InitializeCmd,
ethL1IFCrntPMOPRMinValue FixedX10,
ethL1IFCrntPMOPRMinTimeStamp DateAndTime,
ethL1IFCrntPMOPRMinValidity PMValidity,
ethL1IFCrntPMOPRMinInitialize InitializeCmd,
ethL1IFCrntPMOPRMaxValue FixedX10,
ethL1IFCrntPMOPRMaxTimeStamp DateAndTime,
ethL1IFCrntPMOPRMaxValidity PMValidity,
ethL1IFCrntPMOPRMaxInitialize InitializeCmd,
ethL1IFCrntPMOPRAvgValue FixedX10,
ethL1IFCrntPMOPRAvgTimeStamp DateAndTime,
ethL1IFCrntPMOPRAvgValidity PMValidity,
ethL1IFCrntPMOPRAvgInitialize InitializeCmd,
ethL1IFCrntPMOPTMinValue FixedX10,
ethL1IFCrntPMOPTMinTimeStamp DateAndTime,
ethL1IFCrntPMOPTMinValidity PMValidity,
ethL1IFCrntPMOPTMinInitialize InitializeCmd,
ethL1IFCrntPMOPTMaxValue FixedX10,
ethL1IFCrntPMOPTMaxTimeStamp DateAndTime,
ethL1IFCrntPMOPTMaxValidity PMValidity,
ethL1IFCrntPMOPTMaxInitialize InitializeCmd,
ethL1IFCrntPMOPTAvgValue FixedX10,
ethL1IFCrntPMOPTAvgTimeStamp DateAndTime,
ethL1IFCrntPMOPTAvgValidity PMValidity,
ethL1IFCrntPMOPTAvgInitialize InitializeCmd }
ethL1IFCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the Ethernet Layer 1 facility targeted for
PMs is provisioned."
::= { ethL1IFCrntPMEntry 1 }
ethL1IFCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the Ethernet Layer 1 facility targeted
for PMs is provisioned."
::= { ethL1IFCrntPMEntry 2 }
ethL1IFCrntPMPortTypeIdx OBJECT-TYPE
SYNTAX PvxL1PortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of Ethernet Layer 1 port
targeted for PMs."
::= { ethL1IFCrntPMEntry 3 }
ethL1IFCrntPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the identified type
targeted for PMs."
::= { ethL1IFCrntPMEntry 4 }
ethL1IFCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { ethL1IFCrntPMEntry 5 }
ethL1IFCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the Ethernet Layer 1 facility
port."
::= { ethL1IFCrntPMEntry 6 }
ethL1IFCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { ethL1IFCrntPMEntry 7 }
ethL1IFCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { ethL1IFCrntPMEntry 8 }
ethL1IFCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the Ethernet Layer 1 facility
port."
::= { ethL1IFCrntPMEntry 9 }
ethL1IFCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { ethL1IFCrntPMEntry 10 }
ethL1IFCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { ethL1IFCrntPMEntry 11 }
ethL1IFCrntPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the Ethernet Layer 1 facility port."
::= { ethL1IFCrntPMEntry 12 }
ethL1IFCrntPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { ethL1IFCrntPMEntry 13 }
ethL1IFCrntPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { ethL1IFCrntPMEntry 14 }
ethL1IFCrntPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the Ethernet Layer 1 facility port."
::= { ethL1IFCrntPMEntry 15 }
ethL1IFCrntPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { ethL1IFCrntPMEntry 16 }
ethL1IFCrntPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { ethL1IFCrntPMEntry 17 }
ethL1IFCrntPMSupplyVoltage2Value OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A second supply voltage value measured on the Ethernet Layer 1 facility port.
This object is available only for XFP-equipped Ethernet Interface ports."
::= { ethL1IFCrntPMEntry 18 }
ethL1IFCrntPMSupplyVoltage2TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the second supply voltage value."
::= { ethL1IFCrntPMEntry 19 }
ethL1IFCrntPMSupplyVoltage2Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided second supply voltage value."
::= { ethL1IFCrntPMEntry 20 }
ethL1IFCrntPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the Ethernet Layer 1 facility port."
::= { ethL1IFCrntPMEntry 21 }
ethL1IFCrntPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { ethL1IFCrntPMEntry 22 }
ethL1IFCrntPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { ethL1IFCrntPMEntry 23 }
ethL1IFCrntPMCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of 8B/10B coding violations. This object is only available
on Gigabit Ethernet ports."
::= { ethL1IFCrntPMEntry 24 }
ethL1IFCrntPMCVTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the coding violations value."
::= { ethL1IFCrntPMEntry 25 }
ethL1IFCrntPMCVValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided coding violations
value."
::= { ethL1IFCrntPMEntry 26 }
ethL1IFCrntPMCVInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMCVValue object
to 0."
::= { ethL1IFCrntPMEntry 27 }
ethL1IFCrntPMINVBLKValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of invalid blocks. This object is only available
on 10 Gigabit Ethernet ports."
::= { ethL1IFCrntPMEntry 28 }
ethL1IFCrntPMINVBLKTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the invalid blocks value."
::= { ethL1IFCrntPMEntry 29 }
ethL1IFCrntPMINVBLKValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided invalid blocks
value."
::= { ethL1IFCrntPMEntry 30 }
ethL1IFCrntPMINVBLKInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMINVBLKValue object
to 0."
::= { ethL1IFCrntPMEntry 31 }
ethL1IFCrntPMESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Ethernet Layer 1 errored seconds."
::= { ethL1IFCrntPMEntry 32 }
ethL1IFCrntPMESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the Ethernet Layer 1 errored seconds value."
::= { ethL1IFCrntPMEntry 33 }
ethL1IFCrntPMESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided Ethernet Layer 1 errored seconds
value."
::= { ethL1IFCrntPMEntry 34 }
ethL1IFCrntPMESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMESValue object
to 0."
::= { ethL1IFCrntPMEntry 35 }
ethL1IFCrntPMSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Ethernet Layer 1 severely errored seconds."
::= { ethL1IFCrntPMEntry 36 }
ethL1IFCrntPMSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the Ethernet Layer 1 severely errored seconds
value."
::= { ethL1IFCrntPMEntry 37 }
ethL1IFCrntPMSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided Ethernet Layer 1 severely errored
seconds value."
::= { ethL1IFCrntPMEntry 38 }
ethL1IFCrntPMSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMSESValue object
to 0."
::= { ethL1IFCrntPMEntry 39 }
ethL1IFCrntPMOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored blocks."
::= { ethL1IFCrntPMEntry 40 }
ethL1IFCrntPMOTUEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored blocks value."
::= { ethL1IFCrntPMEntry 41 }
ethL1IFCrntPMOTUEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored blocks value."
::= { ethL1IFCrntPMEntry 42 }
ethL1IFCrntPMOTUEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOTUEBValue object
to 0."
::= { ethL1IFCrntPMEntry 43 }
ethL1IFCrntPMOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer background block
errors."
::= { ethL1IFCrntPMEntry 44 }
ethL1IFCrntPMOTUBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
background block errors value."
::= { ethL1IFCrntPMEntry 45 }
ethL1IFCrntPMOTUBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer background block errors value."
::= { ethL1IFCrntPMEntry 46 }
ethL1IFCrntPMOTUBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOTUBBEValue object
to 0."
::= { ethL1IFCrntPMEntry 47 }
ethL1IFCrntPMOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored seconds."
::= { ethL1IFCrntPMEntry 48 }
ethL1IFCrntPMOTUESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored seconds value."
::= { ethL1IFCrntPMEntry 49 }
ethL1IFCrntPMOTUESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored seconds value."
::= { ethL1IFCrntPMEntry 50 }
ethL1IFCrntPMOTUESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOTUESValue object
to 0."
::= { ethL1IFCrntPMEntry 51 }
ethL1IFCrntPMOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer severely errored
seconds."
::= { ethL1IFCrntPMEntry 52 }
ethL1IFCrntPMOTUSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
severely errored seconds value."
::= { ethL1IFCrntPMEntry 53 }
ethL1IFCrntPMOTUSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer severely errored seconds value."
::= { ethL1IFCrntPMEntry 54 }
ethL1IFCrntPMOTUSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOTUSESValue object
to 0."
::= { ethL1IFCrntPMEntry 55 }
ethL1IFCrntPMOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer out-of-frame seconds."
::= { ethL1IFCrntPMEntry 56 }
ethL1IFCrntPMOTUOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
out-of-frame seconds value."
::= { ethL1IFCrntPMEntry 57 }
ethL1IFCrntPMOTUOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer out-of-frame seconds value."
::= { ethL1IFCrntPMEntry 58 }
ethL1IFCrntPMOTUOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOTUOFSValue object
to 0."
::= { ethL1IFCrntPMEntry 59 }
ethL1IFCrntPMNBITCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bits corrected. This object
applies only to xGigE line ports provisioned for OTN line
mapping with Forward Eror Correction (FEC)."
::= { ethL1IFCrntPMEntry 60 }
ethL1IFCrntPMNBITCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bits corrected
value."
::= { ethL1IFCrntPMEntry 61 }
ethL1IFCrntPMNBITCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bits
corrected value."
::= { ethL1IFCrntPMEntry 62 }
ethL1IFCrntPMNBITCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMNBITCRValue object
to 0."
::= { ethL1IFCrntPMEntry 63 }
ethL1IFCrntPMNBYTCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bytes corrected. This object
applies only to xGigE line ports provisioned for OTN line
mapping with Forward Eror Correction (FEC)."
::= { ethL1IFCrntPMEntry 64 }
ethL1IFCrntPMNBYTCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bytes corrected
value."
::= { ethL1IFCrntPMEntry 65 }
ethL1IFCrntPMNBYTCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bytes
corrected value."
::= { ethL1IFCrntPMEntry 66 }
ethL1IFCrntPMNBYTCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMNBYTCRValue object
to 0."
::= { ethL1IFCrntPMEntry 67 }
ethL1IFCrntPMUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of uncorrectable codewords. This object
applies only to xGigE line ports provisioned for OTN line
mapping with Forward Eror Correction (FEC)."
::= { ethL1IFCrntPMEntry 68 }
ethL1IFCrntPMUNCRCDWTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the uncorrectable codewords value."
::= { ethL1IFCrntPMEntry 69 }
ethL1IFCrntPMUNCRCDWValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided uncorrectable codewords
value."
::= { ethL1IFCrntPMEntry 70 }
ethL1IFCrntPMUNCRCDWInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMUNCRCDWValue object
to 0."
::= { ethL1IFCrntPMEntry 71 }
ethL1IFCrntPMOTNBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous BER of the line port."
::= { ethL1IFCrntPMEntry 72 }
ethL1IFCrntPMOTNBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous BER."
::= { ethL1IFCrntPMEntry 73 }
ethL1IFCrntPMOTNBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous BER."
::= { ethL1IFCrntPMEntry 74 }
ethL1IFCrntPMOTNBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOTNBERValue object
to 0."
::= { ethL1IFCrntPMEntry 75 }
ethL1IFCrntPMOTNAVGBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The interval/average BER of the line port."
::= { ethL1IFCrntPMEntry 76 }
ethL1IFCrntPMOTNAVGBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the interval/average BER."
::= { ethL1IFCrntPMEntry 77 }
ethL1IFCrntPMOTNAVGBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided interval/average BER."
::= { ethL1IFCrntPMEntry 78 }
ethL1IFCrntPMOTNAVGBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOTNAVGBERValue object
to 0."
::= { ethL1IFCrntPMEntry 79 }
ethL1IFCrntPMNBITCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bits corrected. This object
applies only to xGigE line ports provisioned for OTN line
mapping with Forward Eror Correction (FEC)."
::= { ethL1IFCrntPMEntry 80 }
ethL1IFCrntPMNBITCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bits corrected
value."
::= { ethL1IFCrntPMEntry 81 }
ethL1IFCrntPMNBITCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bits
corrected value."
::= { ethL1IFCrntPMEntry 82 }
ethL1IFCrntPMNBITCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMNBITCR64BitValue
object to 0."
::= { ethL1IFCrntPMEntry 83 }
ethL1IFCrntPMNBYTCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bytes corrected. This object
applies only to xGigE line ports provisioned for OTN line
mapping with Forward Eror Correction (FEC)."
::= { ethL1IFCrntPMEntry 84 }
ethL1IFCrntPMNBYTCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bytes corrected
value."
::= { ethL1IFCrntPMEntry 85 }
ethL1IFCrntPMNBYTCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bytes
corrected value."
::= { ethL1IFCrntPMEntry 86 }
ethL1IFCrntPMNBYTCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMNBYTCR64BitValue
object to 0."
::= { ethL1IFCrntPMEntry 87 }
ethL1IFCrntPMUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds. This object is only available
on Gigabit Ethernet ports."
::= { ethL1IFCrntPMEntry 88 }
ethL1IFCrntPMUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the unavailable seconds
value."
::= { ethL1IFCrntPMEntry 89 }
ethL1IFCrntPMUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided unavailable
seconds value."
::= { ethL1IFCrntPMEntry 90 }
ethL1IFCrntPMUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMUASValue
object to 0."
::= { ethL1IFCrntPMEntry 91 }
ethL1IFCrntPMOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer unavailable seconds."
::= { ethL1IFCrntPMEntry 92 }
ethL1IFCrntPMOTUUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
unavailable seconds value."
::= { ethL1IFCrntPMEntry 93 }
ethL1IFCrntPMOTUUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer unavailable seconds value."
::= { ethL1IFCrntPMEntry 94 }
ethL1IFCrntPMOTUUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOTUUASValue object
to 0."
::= { ethL1IFCrntPMEntry 95 }
ethL1IFCrntPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { ethL1IFCrntPMEntry 96 }
ethL1IFCrntPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { ethL1IFCrntPMEntry 97 }
ethL1IFCrntPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { ethL1IFCrntPMEntry 98 }
ethL1IFCrntPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOPRMinValue
object to 0."
::= { ethL1IFCrntPMEntry 99 }
ethL1IFCrntPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { ethL1IFCrntPMEntry 100 }
ethL1IFCrntPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { ethL1IFCrntPMEntry 101 }
ethL1IFCrntPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { ethL1IFCrntPMEntry 102 }
ethL1IFCrntPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOPRMaxValue
object to 0."
::= { ethL1IFCrntPMEntry 103 }
ethL1IFCrntPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { ethL1IFCrntPMEntry 104 }
ethL1IFCrntPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { ethL1IFCrntPMEntry 105 }
ethL1IFCrntPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { ethL1IFCrntPMEntry 106 }
ethL1IFCrntPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOPRAvgValue
object to 0."
::= { ethL1IFCrntPMEntry 107 }
ethL1IFCrntPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { ethL1IFCrntPMEntry 108 }
ethL1IFCrntPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { ethL1IFCrntPMEntry 109 }
ethL1IFCrntPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { ethL1IFCrntPMEntry 110 }
ethL1IFCrntPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOPTMinValue
object to 0."
::= { ethL1IFCrntPMEntry 111 }
ethL1IFCrntPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { ethL1IFCrntPMEntry 112 }
ethL1IFCrntPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { ethL1IFCrntPMEntry 113 }
ethL1IFCrntPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { ethL1IFCrntPMEntry 114 }
ethL1IFCrntPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOPTMaxValue
object to 0."
::= { ethL1IFCrntPMEntry 115 }
ethL1IFCrntPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { ethL1IFCrntPMEntry 116 }
ethL1IFCrntPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { ethL1IFCrntPMEntry 117 }
ethL1IFCrntPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { ethL1IFCrntPMEntry 118 }
ethL1IFCrntPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFCrntPMOPTAvgValue
object to 0."
::= { ethL1IFCrntPMEntry 119 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical Ethernet Layer 1 Interface
-- Performance Monitoring statistics
-----------------------------------------------------------------------
ethL1IFHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthL1IFHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics collected
for the Ethernet Layer 1 Interface facilities on the NE."
::= { performance 27 }
ethL1IFHistPMEntry OBJECT-TYPE
SYNTAX EthL1IFHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Ethernet Layer 1 Interface historical
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a historical
measurement interval for a given Ethernet Layer 1 Interface facility."
INDEX { ethL1IFHistPMShelfIdx,
ethL1IFHistPMSlotIdx,
ethL1IFHistPMPortTypeIdx,
ethL1IFHistPMPortIdx,
ethL1IFHistPMIntervalTypeIdx,
ethL1IFHistPMIntervalIdx }
::= { ethL1IFHistPMTable 1 }
EthL1IFHistPMEntry ::= SEQUENCE { ethL1IFHistPMShelfIdx INTEGER,
ethL1IFHistPMSlotIdx INTEGER,
ethL1IFHistPMPortTypeIdx PvxL1PortType,
ethL1IFHistPMPortIdx INTEGER,
ethL1IFHistPMIntervalTypeIdx PMIntervalType,
ethL1IFHistPMIntervalIdx INTEGER,
ethL1IFHistPMOPRValue FixedX10,
ethL1IFHistPMOPRTimeStamp DateAndTime,
ethL1IFHistPMOPRValidity PMValidity,
ethL1IFHistPMOPTValue FixedX10,
ethL1IFHistPMOPTTimeStamp DateAndTime,
ethL1IFHistPMOPTValidity PMValidity,
ethL1IFHistPMTempValue INTEGER,
ethL1IFHistPMTempTimeStamp DateAndTime,
ethL1IFHistPMTempValidity PMValidity,
ethL1IFHistPMSupplyVoltageValue FixedX10,
ethL1IFHistPMSupplyVoltageTimeStamp DateAndTime,
ethL1IFHistPMSupplyVoltageValidity PMValidity,
ethL1IFHistPMSupplyVoltage2Value FixedX10,
ethL1IFHistPMSupplyVoltage2TimeStamp DateAndTime,
ethL1IFHistPMSupplyVoltage2Validity PMValidity,
ethL1IFHistPMLBCValue INTEGER,
ethL1IFHistPMLBCTimeStamp DateAndTime,
ethL1IFHistPMLBCValidity PMValidity,
ethL1IFHistPMCVValue Unsigned32,
ethL1IFHistPMCVTimeStamp DateAndTime,
ethL1IFHistPMCVValidity PMValidity,
ethL1IFHistPMCVInitialize InitializeCmd,
ethL1IFHistPMINVBLKValue Unsigned32,
ethL1IFHistPMINVBLKTimeStamp DateAndTime,
ethL1IFHistPMINVBLKValidity PMValidity,
ethL1IFHistPMINVBLKInitialize InitializeCmd,
ethL1IFHistPMESValue Unsigned32,
ethL1IFHistPMESTimeStamp DateAndTime,
ethL1IFHistPMESValidity PMValidity,
ethL1IFHistPMESInitialize InitializeCmd,
ethL1IFHistPMSESValue Unsigned32,
ethL1IFHistPMSESTimeStamp DateAndTime,
ethL1IFHistPMSESValidity PMValidity,
ethL1IFHistPMSESInitialize InitializeCmd,
ethL1IFHistPMOTUEBValue Unsigned32,
ethL1IFHistPMOTUEBTimeStamp DateAndTime,
ethL1IFHistPMOTUEBValidity PMValidity,
ethL1IFHistPMOTUEBInitialize InitializeCmd,
ethL1IFHistPMOTUBBEValue Unsigned32,
ethL1IFHistPMOTUBBETimeStamp DateAndTime,
ethL1IFHistPMOTUBBEValidity PMValidity,
ethL1IFHistPMOTUBBEInitialize InitializeCmd,
ethL1IFHistPMOTUESValue Unsigned32,
ethL1IFHistPMOTUESTimeStamp DateAndTime,
ethL1IFHistPMOTUESValidity PMValidity,
ethL1IFHistPMOTUESInitialize InitializeCmd,
ethL1IFHistPMOTUSESValue Unsigned32,
ethL1IFHistPMOTUSESTimeStamp DateAndTime,
ethL1IFHistPMOTUSESValidity PMValidity,
ethL1IFHistPMOTUSESInitialize InitializeCmd,
ethL1IFHistPMOTUOFSValue Unsigned32,
ethL1IFHistPMOTUOFSTimeStamp DateAndTime,
ethL1IFHistPMOTUOFSValidity PMValidity,
ethL1IFHistPMOTUOFSInitialize InitializeCmd,
ethL1IFHistPMNBITCRValue Unsigned32,
ethL1IFHistPMNBITCRTimeStamp DateAndTime,
ethL1IFHistPMNBITCRValidity PMValidity,
ethL1IFHistPMNBITCRInitialize InitializeCmd,
ethL1IFHistPMNBYTCRValue Unsigned32,
ethL1IFHistPMNBYTCRTimeStamp DateAndTime,
ethL1IFHistPMNBYTCRValidity PMValidity,
ethL1IFHistPMNBYTCRInitialize InitializeCmd,
ethL1IFHistPMUNCRCDWValue Unsigned32,
ethL1IFHistPMUNCRCDWTimeStamp DateAndTime,
ethL1IFHistPMUNCRCDWValidity PMValidity,
ethL1IFHistPMUNCRCDWInitialize InitializeCmd,
ethL1IFHistPMOTNBERValue DisplayString,
ethL1IFHistPMOTNBERTimeStamp DateAndTime,
ethL1IFHistPMOTNBERValidity PMValidity,
ethL1IFHistPMOTNBERInitialize InitializeCmd,
ethL1IFHistPMOTNAVGBERValue DisplayString,
ethL1IFHistPMOTNAVGBERTimeStamp DateAndTime,
ethL1IFHistPMOTNAVGBERValidity PMValidity,
ethL1IFHistPMOTNAVGBERInitialize InitializeCmd,
ethL1IFHistPMNBITCR64BitValue Unsigned64,
ethL1IFHistPMNBITCR64BitTimeStamp DateAndTime,
ethL1IFHistPMNBITCR64BitValidity PMValidity,
ethL1IFHistPMNBITCR64BitInitialize InitializeCmd,
ethL1IFHistPMNBYTCR64BitValue Unsigned64,
ethL1IFHistPMNBYTCR64BitTimeStamp DateAndTime,
ethL1IFHistPMNBYTCR64BitValidity PMValidity,
ethL1IFHistPMNBYTCR64BitInitialize InitializeCmd,
ethL1IFHistPMUASValue Unsigned32,
ethL1IFHistPMUASTimeStamp DateAndTime,
ethL1IFHistPMUASValidity PMValidity,
ethL1IFHistPMUASInitialize InitializeCmd,
ethL1IFHistPMOTUUASValue Unsigned32,
ethL1IFHistPMOTUUASTimeStamp DateAndTime,
ethL1IFHistPMOTUUASValidity PMValidity,
ethL1IFHistPMOTUUASInitialize InitializeCmd,
ethL1IFHistPMOPRMinValue FixedX10,
ethL1IFHistPMOPRMinTimeStamp DateAndTime,
ethL1IFHistPMOPRMinValidity PMValidity,
ethL1IFHistPMOPRMinInitialize InitializeCmd,
ethL1IFHistPMOPRMaxValue FixedX10,
ethL1IFHistPMOPRMaxTimeStamp DateAndTime,
ethL1IFHistPMOPRMaxValidity PMValidity,
ethL1IFHistPMOPRMaxInitialize InitializeCmd,
ethL1IFHistPMOPRAvgValue FixedX10,
ethL1IFHistPMOPRAvgTimeStamp DateAndTime,
ethL1IFHistPMOPRAvgValidity PMValidity,
ethL1IFHistPMOPRAvgInitialize InitializeCmd,
ethL1IFHistPMOPTMinValue FixedX10,
ethL1IFHistPMOPTMinTimeStamp DateAndTime,
ethL1IFHistPMOPTMinValidity PMValidity,
ethL1IFHistPMOPTMinInitialize InitializeCmd,
ethL1IFHistPMOPTMaxValue FixedX10,
ethL1IFHistPMOPTMaxTimeStamp DateAndTime,
ethL1IFHistPMOPTMaxValidity PMValidity,
ethL1IFHistPMOPTMaxInitialize InitializeCmd,
ethL1IFHistPMOPTAvgValue FixedX10,
ethL1IFHistPMOPTAvgTimeStamp DateAndTime,
ethL1IFHistPMOPTAvgValidity PMValidity,
ethL1IFHistPMOPTAvgInitialize InitializeCmd }
ethL1IFHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the Ethernet Layer 1 facility targeted for
PMs is provisioned."
::= { ethL1IFHistPMEntry 1 }
ethL1IFHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the Ethernet Layer 1 facility targeted
for PMs is provisioned."
::= { ethL1IFHistPMEntry 2 }
ethL1IFHistPMPortTypeIdx OBJECT-TYPE
SYNTAX PvxL1PortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of Ethernet Layer 1 port
targeted for PMs."
::= { ethL1IFHistPMEntry 3 }
ethL1IFHistPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the identified type
targeted for PMs."
::= { ethL1IFHistPMEntry 4 }
ethL1IFHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { ethL1IFHistPMEntry 5 }
ethL1IFHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1..96 for 15-minute
bins, and for 1-day historical bins, the value is 1."
::= { ethL1IFHistPMEntry 6 }
ethL1IFHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the Ethernet Layer 1 facility
port."
::= { ethL1IFHistPMEntry 7 }
ethL1IFHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { ethL1IFHistPMEntry 8 }
ethL1IFHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { ethL1IFHistPMEntry 9 }
ethL1IFHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the Ethernet Layer 1 facility
port."
::= { ethL1IFHistPMEntry 10 }
ethL1IFHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { ethL1IFHistPMEntry 11 }
ethL1IFHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { ethL1IFHistPMEntry 12 }
ethL1IFHistPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the Ethernet Layer 1 facility port."
::= { ethL1IFHistPMEntry 13 }
ethL1IFHistPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { ethL1IFHistPMEntry 14 }
ethL1IFHistPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { ethL1IFHistPMEntry 15 }
ethL1IFHistPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the Ethernet Layer 1 facility port."
::= { ethL1IFHistPMEntry 16 }
ethL1IFHistPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { ethL1IFHistPMEntry 17 }
ethL1IFHistPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { ethL1IFHistPMEntry 18 }
ethL1IFHistPMSupplyVoltage2Value OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A second supply voltage value measured on the Ethernet Layer 1 facility port.
This object is available only for XFP-equipped Ethernet Interface ports."
::= { ethL1IFHistPMEntry 19 }
ethL1IFHistPMSupplyVoltage2TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the second supply voltage value."
::= { ethL1IFHistPMEntry 20 }
ethL1IFHistPMSupplyVoltage2Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided second supply voltage value."
::= { ethL1IFHistPMEntry 21 }
ethL1IFHistPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the Ethernet Layer 1 facility port."
::= { ethL1IFHistPMEntry 22 }
ethL1IFHistPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { ethL1IFHistPMEntry 23 }
ethL1IFHistPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { ethL1IFHistPMEntry 24 }
ethL1IFHistPMCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of 8B/10B coding violations. This object is only available
on Gigabit Ethernet ports."
::= { ethL1IFHistPMEntry 25 }
ethL1IFHistPMCVTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the coding violations value."
::= { ethL1IFHistPMEntry 26 }
ethL1IFHistPMCVValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided coding violations
value."
::= { ethL1IFHistPMEntry 27 }
ethL1IFHistPMCVInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMCVValue object
to 0."
::= { ethL1IFHistPMEntry 28 }
ethL1IFHistPMINVBLKValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of invalid blocks. This object is only available
on 10 Gigabit Ethernet ports."
::= { ethL1IFHistPMEntry 29 }
ethL1IFHistPMINVBLKTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the invalid blocks value."
::= { ethL1IFHistPMEntry 30 }
ethL1IFHistPMINVBLKValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided invalid blocks
value."
::= { ethL1IFHistPMEntry 31 }
ethL1IFHistPMINVBLKInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMINVBLKValue object
to 0."
::= { ethL1IFHistPMEntry 32 }
ethL1IFHistPMESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Ethernet Layer 1 errored seconds."
::= { ethL1IFHistPMEntry 33 }
ethL1IFHistPMESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the Ethernet Layer 1 errored seconds value."
::= { ethL1IFHistPMEntry 34 }
ethL1IFHistPMESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided Ethernet Layer 1 errored seconds
value."
::= { ethL1IFHistPMEntry 35 }
ethL1IFHistPMESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMESValue object
to 0."
::= { ethL1IFHistPMEntry 36 }
ethL1IFHistPMSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of Ethernet Layer 1 severely errored seconds."
::= { ethL1IFHistPMEntry 37 }
ethL1IFHistPMSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the Ethernet Layer 1 severely errored seconds
value."
::= { ethL1IFHistPMEntry 38 }
ethL1IFHistPMSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided Ethernet Layer 1 severely errored
seconds value."
::= { ethL1IFHistPMEntry 39 }
ethL1IFHistPMSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMSESValue object
to 0."
::= { ethL1IFHistPMEntry 40 }
ethL1IFHistPMOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored blocks."
::= { ethL1IFHistPMEntry 41 }
ethL1IFHistPMOTUEBTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored blocks value."
::= { ethL1IFHistPMEntry 42 }
ethL1IFHistPMOTUEBValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored blocks value."
::= { ethL1IFHistPMEntry 43 }
ethL1IFHistPMOTUEBInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOTUEBValue object
to 0."
::= { ethL1IFHistPMEntry 44 }
ethL1IFHistPMOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer background block
errors."
::= { ethL1IFHistPMEntry 45 }
ethL1IFHistPMOTUBBETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
background block errors value."
::= { ethL1IFHistPMEntry 46 }
ethL1IFHistPMOTUBBEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer background block errors value."
::= { ethL1IFHistPMEntry 47 }
ethL1IFHistPMOTUBBEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOTUBBEValue object
to 0."
::= { ethL1IFHistPMEntry 48 }
ethL1IFHistPMOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer errored seconds."
::= { ethL1IFHistPMEntry 49 }
ethL1IFHistPMOTUESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
errored seconds value."
::= { ethL1IFHistPMEntry 50 }
ethL1IFHistPMOTUESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer errored seconds value."
::= { ethL1IFHistPMEntry 51 }
ethL1IFHistPMOTUESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOTUESValue object
to 0."
::= { ethL1IFHistPMEntry 52 }
ethL1IFHistPMOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer severely errored
seconds."
::= { ethL1IFHistPMEntry 53 }
ethL1IFHistPMOTUSESTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
severely errored seconds value."
::= { ethL1IFHistPMEntry 54 }
ethL1IFHistPMOTUSESValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer severely errored seconds value."
::= { ethL1IFHistPMEntry 55 }
ethL1IFHistPMOTUSESInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOTUSESValue object
to 0."
::= { ethL1IFHistPMEntry 56 }
ethL1IFHistPMOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer out-of-frame seconds."
::= { ethL1IFHistPMEntry 57 }
ethL1IFHistPMOTUOFSTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
out-of-frame seconds value."
::= { ethL1IFHistPMEntry 58 }
ethL1IFHistPMOTUOFSValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer out-of-frame seconds value."
::= { ethL1IFHistPMEntry 59 }
ethL1IFHistPMOTUOFSInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOTUOFSValue object
to 0."
::= { ethL1IFHistPMEntry 60 }
ethL1IFHistPMNBITCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bits corrected."
::= { ethL1IFHistPMEntry 61 }
ethL1IFHistPMNBITCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bits corrected
value."
::= { ethL1IFHistPMEntry 62 }
ethL1IFHistPMNBITCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bits
corrected value."
::= { ethL1IFHistPMEntry 63 }
ethL1IFHistPMNBITCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMNBITCRValue object
to 0."
::= { ethL1IFHistPMEntry 64 }
ethL1IFHistPMNBYTCRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of the number of bytes corrected. This object
applies only to OC-192 line port provisioned for OTN line
mapping."
::= { ethL1IFHistPMEntry 65 }
ethL1IFHistPMNBYTCRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the number of bytes corrected
value."
::= { ethL1IFHistPMEntry 66 }
ethL1IFHistPMNBYTCRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided number of bytes
corrected value."
::= { ethL1IFHistPMEntry 67 }
ethL1IFHistPMNBYTCRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMNBYTCRValue object
to 0."
::= { ethL1IFHistPMEntry 68 }
ethL1IFHistPMUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of uncorrectable codewords. This object applies only
to OC-192 line port provisioned for OTN line mapping."
::= { ethL1IFHistPMEntry 69 }
ethL1IFHistPMUNCRCDWTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the uncorrectable codewords value."
::= { ethL1IFHistPMEntry 70 }
ethL1IFHistPMUNCRCDWValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided uncorrectable codewords
value."
::= { ethL1IFHistPMEntry 71 }
ethL1IFHistPMUNCRCDWInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMUNCRCDWValue object
to 0."
::= { ethL1IFHistPMEntry 72 }
ethL1IFHistPMOTNBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The instantaneous BER of the line port."
::= { ethL1IFHistPMEntry 73 }
ethL1IFHistPMOTNBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the instantaneous BER."
::= { ethL1IFHistPMEntry 74 }
ethL1IFHistPMOTNBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided instantaneous BER."
::= { ethL1IFHistPMEntry 75 }
ethL1IFHistPMOTNBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOTNBERValue object
to 0."
::= { ethL1IFHistPMEntry 76 }
ethL1IFHistPMOTNAVGBERValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The interval/average BER of the line port."
::= { ethL1IFHistPMEntry 77 }
ethL1IFHistPMOTNAVGBERTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the interval/average BER."
::= { ethL1IFHistPMEntry 78 }
ethL1IFHistPMOTNAVGBERValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided interval/average BER."
::= { ethL1IFHistPMEntry 79 }
ethL1IFHistPMOTNAVGBERInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOTNAVGBERValue object
to 0."
::= { ethL1IFHistPMEntry 80 }
ethL1IFHistPMNBITCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bits corrected. This object
applies only to xGigE line ports provisioned for OTN line
mapping with Forward Eror Correction (FEC)."
::= { ethL1IFHistPMEntry 81 }
ethL1IFHistPMNBITCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bits corrected
value."
::= { ethL1IFHistPMEntry 82 }
ethL1IFHistPMNBITCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bits
corrected value."
::= { ethL1IFHistPMEntry 83 }
ethL1IFHistPMNBITCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMNBITCR64BitValue
object to 0."
::= { ethL1IFHistPMEntry 84 }
ethL1IFHistPMNBYTCR64BitValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 64-bit count of the number of bytes corrected. This object
applies only to xGigE line ports provisioned for OTN line
mapping with Forward Eror Correction (FEC)."
::= { ethL1IFHistPMEntry 85 }
ethL1IFHistPMNBYTCR64BitTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the 64-bit number of bytes corrected
value."
::= { ethL1IFHistPMEntry 86 }
ethL1IFHistPMNBYTCR64BitValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided 64-bit number of bytes
corrected value."
::= { ethL1IFHistPMEntry 87 }
ethL1IFHistPMNBYTCR64BitInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMNBYTCR64BitValue
object to 0."
::= { ethL1IFHistPMEntry 88 }
ethL1IFHistPMUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of unavailable seconds. This object is only available
on Gigabit Ethernet ports."
::= { ethL1IFHistPMEntry 89 }
ethL1IFHistPMUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the unavailable seconds
value."
::= { ethL1IFHistPMEntry 90 }
ethL1IFHistPMUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided unavailable
seconds value."
::= { ethL1IFHistPMEntry 91 }
ethL1IFHistPMUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMUASValue
object to 0."
::= { ethL1IFHistPMEntry 92 }
ethL1IFHistPMOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of OTU digital wrapper layer unavailable seconds."
::= { ethL1IFHistPMEntry 93 }
ethL1IFHistPMOTUUASTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the OTU digital wrapper layer
unavailable seconds value."
::= { ethL1IFHistPMEntry 94 }
ethL1IFHistPMOTUUASValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided OTU digital wrapper
layer unavailable seconds value."
::= { ethL1IFHistPMEntry 95 }
ethL1IFHistPMOTUUASInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOTUUASValue object
to 0."
::= { ethL1IFHistPMEntry 96 }
ethL1IFHistPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { ethL1IFHistPMEntry 97 }
ethL1IFHistPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { ethL1IFHistPMEntry 98 }
ethL1IFHistPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { ethL1IFHistPMEntry 99 }
ethL1IFHistPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOPRMinValue
object to 0."
::= { ethL1IFHistPMEntry 100 }
ethL1IFHistPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { ethL1IFHistPMEntry 101 }
ethL1IFHistPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { ethL1IFHistPMEntry 102 }
ethL1IFHistPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { ethL1IFHistPMEntry 103 }
ethL1IFHistPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOPRMaxValue
object to 0."
::= { ethL1IFHistPMEntry 104 }
ethL1IFHistPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { ethL1IFHistPMEntry 105 }
ethL1IFHistPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { ethL1IFHistPMEntry 106 }
ethL1IFHistPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { ethL1IFHistPMEntry 107 }
ethL1IFHistPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOPRAvgValue
object to 0."
::= { ethL1IFHistPMEntry 108 }
ethL1IFHistPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { ethL1IFHistPMEntry 109 }
ethL1IFHistPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { ethL1IFHistPMEntry 110 }
ethL1IFHistPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { ethL1IFHistPMEntry 111 }
ethL1IFHistPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOPTMinValue
object to 0."
::= { ethL1IFHistPMEntry 112 }
ethL1IFHistPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { ethL1IFHistPMEntry 113 }
ethL1IFHistPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { ethL1IFHistPMEntry 114 }
ethL1IFHistPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { ethL1IFHistPMEntry 115 }
ethL1IFHistPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOPTMaxValue
object to 0."
::= { ethL1IFHistPMEntry 116 }
ethL1IFHistPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { ethL1IFHistPMEntry 117 }
ethL1IFHistPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { ethL1IFHistPMEntry 118 }
ethL1IFHistPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { ethL1IFHistPMEntry 119 }
ethL1IFHistPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the ethL1IFHistPMOPTAvgValue
object to 0."
::= { ethL1IFHistPMEntry 120 }
-----------------------------------------------------------------------
-- Objects used to manage Ethernet Layer 1 Interface Performance
-- Monitoring Threshold Levels
-----------------------------------------------------------------------
ethL1IFPMThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthL1IFPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of threshold levels for performance monitoring counter
values on Ethernet Layer 1 facilities, that are used in the
generation of threshold crossing alerts."
::= { performance 28 }
ethL1IFPMThresholdEntry OBJECT-TYPE
SYNTAX EthL1IFPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the Ethernet Layer 1 performance
monitoring threshold table. Each row of this table contains a
set of PM thresholds for a given interval type that applies to
an individual Ethernet Layer 1 facility."
INDEX { ethL1IFPMThresholdShelfIdx,
ethL1IFPMThresholdSlotIdx,
ethL1IFPMThresholdPortTypeIdx,
ethL1IFPMThresholdPortIdx,
ethL1IFPMThresholdIntervalTypeIdx }
::= { ethL1IFPMThresholdTable 1 }
EthL1IFPMThresholdEntry ::= SEQUENCE { ethL1IFPMThresholdShelfIdx INTEGER,
ethL1IFPMThresholdSlotIdx INTEGER,
ethL1IFPMThresholdPortTypeIdx PvxL1PortType,
ethL1IFPMThresholdPortIdx INTEGER,
ethL1IFPMThresholdIntervalTypeIdx PMIntervalType,
ethL1IFPMThresholdCVValue Unsigned32,
ethL1IFPMThresholdINVBLKValue Unsigned32,
ethL1IFPMThresholdESValue Unsigned32,
ethL1IFPMThresholdSESValue Unsigned32,
ethL1IFPMThresholdOTUEBValue Unsigned32,
ethL1IFPMThresholdOTUBBEValue Unsigned32,
ethL1IFPMThresholdOTUESValue Unsigned32,
ethL1IFPMThresholdOTUSESValue Unsigned32,
ethL1IFPMThresholdOTUOFSValue Unsigned32,
ethL1IFPMThresholdUNCRCDWValue Unsigned32,
ethL1IFPMThresholdUASValue Unsigned32,
ethL1IFPMThresholdOTUUASValue Unsigned32 }
ethL1IFPMThresholdShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The shelf number on which the Ethernet Layer 1 facility
targeted for PM thresholds is provisioned."
::= { ethL1IFPMThresholdEntry 1 }
ethL1IFPMThresholdSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The slot number on which the Ethernet Layer 1 facility
targeted for PM thresholds is provisioned."
::= { ethL1IFPMThresholdEntry 2 }
ethL1IFPMThresholdPortTypeIdx OBJECT-TYPE
SYNTAX PvxL1PortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of Ethernet Layer 1 port
targeted for PM thresholds."
::= { ethL1IFPMThresholdEntry 3 }
ethL1IFPMThresholdPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the identified type
targeted for PM thresholds."
::= { ethL1IFPMThresholdEntry 4 }
ethL1IFPMThresholdIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length. Thresholds
are supported for the 15-minute and 1-day PM bins only."
::= { ethL1IFPMThresholdEntry 5 }
ethL1IFPMThresholdCVValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of 8B/10B coding
violations. This object is only available
on Gigabit Ethernet ports."
::= { ethL1IFPMThresholdEntry 6 }
ethL1IFPMThresholdINVBLKValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of invalid blocks.
This object is only available
on 10 Gigabit Ethernet ports."
::= { ethL1IFPMThresholdEntry 7 }
ethL1IFPMThresholdESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored
seconds."
::= { ethL1IFPMThresholdEntry 8 }
ethL1IFPMThresholdSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of severely
errored seconds."
::= { ethL1IFPMThresholdEntry 9 }
ethL1IFPMThresholdOTUEBValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored blocks at the OTU
digital wrapper layer."
::= { ethL1IFPMThresholdEntry 10 }
ethL1IFPMThresholdOTUBBEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of background block errors at the
OTU digital wrapper layer."
::= { ethL1IFPMThresholdEntry 11 }
ethL1IFPMThresholdOTUESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of errored seconds at the OTU
digital wrapper layer."
::= { ethL1IFPMThresholdEntry 12 }
ethL1IFPMThresholdOTUSESValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of severely errored seconds at the
OTU digital wrapper layer."
::= { ethL1IFPMThresholdEntry 13 }
ethL1IFPMThresholdOTUOFSValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of out-of-frame seconds at the OTU
digital wrapper layer."
::= { ethL1IFPMThresholdEntry 14 }
ethL1IFPMThresholdUNCRCDWValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of uncorrectable codewords."
::= { ethL1IFPMThresholdEntry 15 }
ethL1IFPMThresholdUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of unavailable seconds."
::= { ethL1IFPMThresholdEntry 16 }
ethL1IFPMThresholdOTUUASValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of unavailable seconds at the
OTU digital wrapper layer."
::= { ethL1IFPMThresholdEntry 17 }
-----------------------------------------------------------------------
-- Objects used to retrieve current Ethernet Layer 2
-- Performance Monitoring statistics for PacketVX Interfaces
-----------------------------------------------------------------------
pvxL2IFCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF PvxL2IFCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the PacketVX Layer2 interfaces on the NE."
::= { performance 29 }
pvxL2IFCrntPMEntry OBJECT-TYPE
SYNTAX PvxL2IFCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the PacketVX Layer 2 current
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a current
measurement interval for a given PVX Layer 2 interface facility."
INDEX { pvxL2IFCrntPMSwitchIdx,
pvxL2IFCrntPMShelfIdx,
pvxL2IFCrntPMSlotIdx,
pvxL2IFCrntPMPortTypeIdx,
pvxL2IFCrntPMPortIdx,
pvxL2IFCrntPMIntervalTypeIdx }
::= { pvxL2IFCrntPMTable 1 }
PvxL2IFCrntPMEntry ::= SEQUENCE { pvxL2IFCrntPMSwitchIdx INTEGER,
pvxL2IFCrntPMShelfIdx INTEGER,
pvxL2IFCrntPMSlotIdx INTEGER,
pvxL2IFCrntPMPortTypeIdx PvxPortType,
pvxL2IFCrntPMPortIdx INTEGER,
pvxL2IFCrntPMIntervalTypeIdx PMIntervalType,
pvxL2IFCrntPMTFRCRXValue Unsigned64,
pvxL2IFCrntPMTFRCRXTimeStamp DateAndTime,
pvxL2IFCrntPMTFRCRXValidity PMValidity,
pvxL2IFCrntPMTFRCRXInitialize InitializeCmd,
pvxL2IFCrntPMTFRCTXValue Unsigned64,
pvxL2IFCrntPMTFRCTXTimeStamp DateAndTime,
pvxL2IFCrntPMTFRCTXValidity PMValidity,
pvxL2IFCrntPMTFRCTXInitialize InitializeCmd,
pvxL2IFCrntPMFRDRValue Unsigned32,
pvxL2IFCrntPMFRDRTimeStamp DateAndTime,
pvxL2IFCrntPMFRDRValidity PMValidity,
pvxL2IFCrntPMFRDRInitialize InitializeCmd,
pvxL2IFCrntPMFCSEValue Unsigned32,
pvxL2IFCrntPMFCSETimeStamp DateAndTime,
pvxL2IFCrntPMFCSEValidity PMValidity,
pvxL2IFCrntPMFCSEInitialize InitializeCmd,
pvxL2IFCrntPMTBYCRXValue Unsigned64,
pvxL2IFCrntPMTBYCRXTimeStamp DateAndTime,
pvxL2IFCrntPMTBYCRXValidity PMValidity,
pvxL2IFCrntPMTBYCRXInitialize InitializeCmd,
pvxL2IFCrntPMTBYCTXValue Unsigned64,
pvxL2IFCrntPMTBYCTXTimeStamp DateAndTime,
pvxL2IFCrntPMTBYCTXValidity PMValidity,
pvxL2IFCrntPMTBYCTXInitialize InitializeCmd,
pvxL2IFCrntPMBCSTValue Unsigned64,
pvxL2IFCrntPMBCSTTimeStamp DateAndTime,
pvxL2IFCrntPMBCSTValidity PMValidity,
pvxL2IFCrntPMBCSTInitialize InitializeCmd,
pvxL2IFCrntPMMCSTValue Unsigned64,
pvxL2IFCrntPMMCSTTimeStamp DateAndTime,
pvxL2IFCrntPMMCSTValidity PMValidity,
pvxL2IFCrntPMMCSTInitialize InitializeCmd,
pvxL2IFCrntPMSIZE64Value Unsigned64,
pvxL2IFCrntPMSIZE64TimeStamp DateAndTime,
pvxL2IFCrntPMSIZE64Validity PMValidity,
pvxL2IFCrntPMSIZE64Initialize InitializeCmd,
pvxL2IFCrntPMSIZE65To127Value Unsigned64,
pvxL2IFCrntPMSIZE65To127TimeStamp DateAndTime,
pvxL2IFCrntPMSIZE65To127Validity PMValidity,
pvxL2IFCrntPMSIZE65To127Initialize InitializeCmd,
pvxL2IFCrntPMSIZE128To255Value Unsigned64,
pvxL2IFCrntPMSIZE128To255TimeStamp DateAndTime,
pvxL2IFCrntPMSIZE128To255Validity PMValidity,
pvxL2IFCrntPMSIZE128To255Initialize InitializeCmd,
pvxL2IFCrntPMSIZE256To511Value Unsigned64,
pvxL2IFCrntPMSIZE256To511TimeStamp DateAndTime,
pvxL2IFCrntPMSIZE256To511Validity PMValidity,
pvxL2IFCrntPMSIZE256To511Initialize InitializeCmd,
pvxL2IFCrntPMSIZE512To1023Value Unsigned64,
pvxL2IFCrntPMSIZE512To1023TimeStamp DateAndTime,
pvxL2IFCrntPMSIZE512To1023Validity PMValidity,
pvxL2IFCrntPMSIZE512To1023Initialize InitializeCmd,
pvxL2IFCrntPMSIZE1024To1518Value Unsigned64,
pvxL2IFCrntPMSIZE1024To1518TimeStamp DateAndTime,
pvxL2IFCrntPMSIZE1024To1518Validity PMValidity,
pvxL2IFCrntPMSIZE1024To1518Initialize InitializeCmd,
pvxL2IFCrntPMSIZEOver1518Value Unsigned64,
pvxL2IFCrntPMSIZEOver1518TimeStamp DateAndTime,
pvxL2IFCrntPMSIZEOver1518Validity PMValidity,
pvxL2IFCrntPMSIZEOver1518Initialize InitializeCmd,
pvxL2IFCrntPMTPFCRXValue Unsigned64,
pvxL2IFCrntPMTPFCRXTimeStamp DateAndTime,
pvxL2IFCrntPMTPFCRXValidity PMValidity,
pvxL2IFCrntPMTPFCRXInitialize InitializeCmd,
pvxL2IFCrntPMTPFCTXValue Unsigned64,
pvxL2IFCrntPMTPFCTXTimeStamp DateAndTime,
pvxL2IFCrntPMTPFCTXValidity PMValidity,
pvxL2IFCrntPMTPFCTXInitialize InitializeCmd,
pvxL2IFCrntPMUSIZEValue Unsigned32,
pvxL2IFCrntPMUSIZETimeStamp DateAndTime,
pvxL2IFCrntPMUSIZEValidity PMValidity,
pvxL2IFCrntPMUSIZEInitialize InitializeCmd,
pvxL2IFCrntPMOSIZEValue Unsigned32,
pvxL2IFCrntPMOSIZETimeStamp DateAndTime,
pvxL2IFCrntPMOSIZEValidity PMValidity,
pvxL2IFCrntPMOSIZEInitialize InitializeCmd,
pvxL2IFCrntPMFRGTValue Unsigned32,
pvxL2IFCrntPMFRGTTimeStamp DateAndTime,
pvxL2IFCrntPMFRGTValidity PMValidity,
pvxL2IFCrntPMFRGTInitialize InitializeCmd}
pvxL2IFCrntPMSwitchIdx OBJECT-TYPE
SYNTAX INTEGER(1..11)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The identifier of the ethernet switch instance on which
the Layer 2 Interface facilitiy is provisioned."
::= {pvxL2IFCrntPMEntry 1 }
pvxL2IFCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the PVX Layer2 IF targeted for
PMs is provisioned. For LAG entities, the shelf number is 0."
::= { pvxL2IFCrntPMEntry 2 }
pvxL2IFCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the PVX Layer2 IF targeted
for PMs is provisioned. For LAG entities, the slot number is 0."
::= { pvxL2IFCrntPMEntry 3 }
pvxL2IFCrntPMPortTypeIdx OBJECT-TYPE
SYNTAX PvxPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PacketVX port on which the Layer 2 Interface facility
is provisioned."
::= { pvxL2IFCrntPMEntry 4 }
pvxL2IFCrntPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the identified type on which the PVX Layer 2 IF
facility targeted for PMs is provisioned."
::= { pvxL2IFCrntPMEntry 5 }
pvxL2IFCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { pvxL2IFCrntPMEntry 6 }
pvxL2IFCrntPMTFRCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total received frame count receieved on the interface."
::= { pvxL2IFCrntPMEntry 7 }
pvxL2IFCrntPMTFRCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total received frame count
value."
::= { pvxL2IFCrntPMEntry 8 }
pvxL2IFCrntPMTFRCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided total received frame
count value."
::= { pvxL2IFCrntPMEntry 9 }
pvxL2IFCrntPMTFRCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMTFRCRXValue object
to 0."
::= { pvxL2IFCrntPMEntry 10 }
pvxL2IFCrntPMTFRCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total transmitted frame count on the interface."
::= { pvxL2IFCrntPMEntry 11 }
pvxL2IFCrntPMTFRCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total transmitted frame
count value."
::= { pvxL2IFCrntPMEntry 12 }
pvxL2IFCrntPMTFRCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided total transmitted
frame count value."
::= { pvxL2IFCrntPMEntry 13 }
pvxL2IFCrntPMTFRCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMTFRCTXValue object
to 0."
::= { pvxL2IFCrntPMEntry 14 }
pvxL2IFCrntPMFRDRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of discarded frames on the interface."
::= { pvxL2IFCrntPMEntry 15 }
pvxL2IFCrntPMFRDRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the discarded frames value."
::= { pvxL2IFCrntPMEntry 16 }
pvxL2IFCrntPMFRDRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided discarded frames
value."
::= { pvxL2IFCrntPMEntry 17 }
pvxL2IFCrntPMFRDRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMFRDRValue object
to 0."
::= { pvxL2IFCrntPMEntry 18 }
pvxL2IFCrntPMFCSEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of frame checksum errors on the interface."
::= { pvxL2IFCrntPMEntry 19 }
pvxL2IFCrntPMFCSETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the frame checksum errors value."
::= { pvxL2IFCrntPMEntry 20 }
pvxL2IFCrntPMFCSEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided frame checksum errors
value."
::= { pvxL2IFCrntPMEntry 21 }
pvxL2IFCrntPMFCSEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMFCSEValue
object to 0."
::= { pvxL2IFCrntPMEntry 22 }
pvxL2IFCrntPMTBYCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total received byte count on the interface."
::= { pvxL2IFCrntPMEntry 23 }
pvxL2IFCrntPMTBYCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total received byte count
value."
::= { pvxL2IFCrntPMEntry 24 }
pvxL2IFCrntPMTBYCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided total received byte
count value."
::= { pvxL2IFCrntPMEntry 25 }
pvxL2IFCrntPMTBYCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMTBYCRXValue
object to 0."
::= { pvxL2IFCrntPMEntry 26 }
pvxL2IFCrntPMTBYCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total transmitted byte count on the interface."
::= { pvxL2IFCrntPMEntry 27 }
pvxL2IFCrntPMTBYCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total transmitted byte count
value."
::= { pvxL2IFCrntPMEntry 28 }
pvxL2IFCrntPMTBYCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided Ftotal transmitted byte
count value."
::= { pvxL2IFCrntPMEntry 29 }
pvxL2IFCrntPMTBYCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMTBYCTXValue
object to 0."
::= { pvxL2IFCrntPMEntry 30 }
pvxL2IFCrntPMBCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
the broadcast address. Note that this does not include
multicast frames."
::= { pvxL2IFCrntPMEntry 31 }
pvxL2IFCrntPMBCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the broadcast packets received
count value."
::= { pvxL2IFCrntPMEntry 32 }
pvxL2IFCrntPMBCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided broadcast packets
received count value."
::= { pvxL2IFCrntPMEntry 33 }
pvxL2IFCrntPMBCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMBCSTValue
object to 0."
::= { pvxL2IFCrntPMEntry 34 }
pvxL2IFCrntPMMCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
a multicast address. Note that this number does not include
frames directed to the broadcast address."
::= { pvxL2IFCrntPMEntry 35 }
pvxL2IFCrntPMMCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multicast packets received
count value."
::= { pvxL2IFCrntPMEntry 36 }
pvxL2IFCrntPMMCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multicast packets
received count value."
::= { pvxL2IFCrntPMEntry 37 }
pvxL2IFCrntPMMCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMMCSTValue
object to 0."
::= { pvxL2IFCrntPMEntry 38 }
pvxL2IFCrntPMSIZE64Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of 64 byte frames received (excluding framing
bits but including FCS octets)."
::= { pvxL2IFCrntPMEntry 39 }
pvxL2IFCrntPMSIZE64TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of 64-byte packets
received."
::= { pvxL2IFCrntPMEntry 40 }
pvxL2IFCrntPMSIZE64Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of 64-byte
packets packets received."
::= { pvxL2IFCrntPMEntry 41 }
pvxL2IFCrntPMSIZE64Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMSIZE64Value
object to 0."
::= { pvxL2IFCrntPMEntry 42 }
pvxL2IFCrntPMSIZE65To127Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 65 to 127 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { pvxL2IFCrntPMEntry 43 }
pvxL2IFCrntPMSIZE65To127TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 65 and
127 bytes."
::= { pvxL2IFCrntPMEntry 44 }
pvxL2IFCrntPMSIZE65To127Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 65 and 127 bytes."
::= { pvxL2IFCrntPMEntry 45 }
pvxL2IFCrntPMSIZE65To127Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFCrntPMSIZE65To127Value object to 0."
::= { pvxL2IFCrntPMEntry 46 }
pvxL2IFCrntPMSIZE128To255Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 128 to 255 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { pvxL2IFCrntPMEntry 47 }
pvxL2IFCrntPMSIZE128To255TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 128
and 255 bytes."
::= { pvxL2IFCrntPMEntry 48 }
pvxL2IFCrntPMSIZE128To255Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 128 and 255 bytes."
::= { pvxL2IFCrntPMEntry 49 }
pvxL2IFCrntPMSIZE128To255Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFCrntPMSIZE128To255Value object to 0."
::= { pvxL2IFCrntPMEntry 50 }
pvxL2IFCrntPMSIZE256To511Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 256 to 511 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { pvxL2IFCrntPMEntry 51 }
pvxL2IFCrntPMSIZE256To511TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 256
and 511 bytes."
::= { pvxL2IFCrntPMEntry 52 }
pvxL2IFCrntPMSIZE256To511Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 256 and 511 bytes."
::= { pvxL2IFCrntPMEntry 53 }
pvxL2IFCrntPMSIZE256To511Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFCrntPMSIZE256To511Value object to 0."
::= { pvxL2IFCrntPMEntry 54 }
pvxL2IFCrntPMSIZE512To1023Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 512 to 1023 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { pvxL2IFCrntPMEntry 55 }
pvxL2IFCrntPMSIZE512To1023TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 512
and 1023 bytes."
::= { pvxL2IFCrntPMEntry 56 }
pvxL2IFCrntPMSIZE512To1023Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 512 and 1023 bytes."
::= { pvxL2IFCrntPMEntry 57 }
pvxL2IFCrntPMSIZE512To1023Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFCrntPMSIZE512To1023Value object to 0."
::= { pvxL2IFCrntPMEntry 58 }
pvxL2IFCrntPMSIZE1024To1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 1024 to 1518
bytes inclusive in length (excluding framing bits but
including FCS octets)."
::= { pvxL2IFCrntPMEntry 59 }
pvxL2IFCrntPMSIZE1024To1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 1024
and 1518 bytes."
::= { pvxL2IFCrntPMEntry 60 }
pvxL2IFCrntPMSIZE1024To1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 1024 and 1518 bytes."
::= { pvxL2IFCrntPMEntry 61 }
pvxL2IFCrntPMSIZE1024To1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFCrntPMSIZE1024To1518Value object to 0."
::= { pvxL2IFCrntPMEntry 62 }
pvxL2IFCrntPMSIZEOver1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are greater than or
equal to 1519 bytes in length (excluding framing bits but
including FCS octets)."
::= { pvxL2IFCrntPMEntry 63 }
pvxL2IFCrntPMSIZEOver1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets over 1518
bytes."
::= { pvxL2IFCrntPMEntry 64 }
pvxL2IFCrntPMSIZEOver1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets over
1518 bytes."
::= { pvxL2IFCrntPMEntry 65 }
pvxL2IFCrntPMSIZEOver1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFCrntPMSIZEOver1518Value object to 0."
::= { pvxL2IFCrntPMEntry 66 }
pvxL2IFCrntPMTPFCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total received pause frame count on the interface."
::= { pvxL2IFCrntPMEntry 67 }
pvxL2IFCrntPMTPFCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total received pause frame
count value."
::= { pvxL2IFCrntPMEntry 68 }
pvxL2IFCrntPMTPFCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided total received pause
frame count value."
::= { pvxL2IFCrntPMEntry 69 }
pvxL2IFCrntPMTPFCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMTPFCRXValue
object to 0."
::= { pvxL2IFCrntPMEntry 70 }
pvxL2IFCrntPMTPFCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total transmitted pause frame count on the interface."
::= { pvxL2IFCrntPMEntry 71 }
pvxL2IFCrntPMTPFCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total transmitted pause frame
count value."
::= { pvxL2IFCrntPMEntry 72 }
pvxL2IFCrntPMTPFCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided total transmitted pause
frame count value."
::= { pvxL2IFCrntPMEntry 73 }
pvxL2IFCrntPMTPFCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMTPFCTXValue
object to 0."
::= { pvxL2IFCrntPMEntry 74 }
pvxL2IFCrntPMUSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets long (excluding framing bits, but including FCS octets)
and were otherwise well formed."
::= { pvxL2IFCrntPMEntry 75 }
pvxL2IFCrntPMUSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of undersized packets."
::= { pvxL2IFCrntPMEntry 76 }
pvxL2IFCrntPMUSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of undersized
packets."
::= { pvxL2IFCrntPMEntry 77 }
pvxL2IFCrntPMUSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMUSIZEValue
object to 0."
::= { pvxL2IFCrntPMEntry 78 }
pvxL2IFCrntPMOSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were longer than 9600
octets (excluding framing bits, but including FCS octets) and
were otherwise well formed."
::= { pvxL2IFCrntPMEntry 79 }
pvxL2IFCrntPMOSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of oversized packets."
::= { pvxL2IFCrntPMEntry 80 }
pvxL2IFCrntPMOSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of oversized
packets."
::= { pvxL2IFCrntPMEntry 81 }
pvxL2IFCrntPMOSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMOSIZEValue
object to 0."
::= { pvxL2IFCrntPMEntry 82 }
pvxL2IFCrntPMFRGTValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets in length (excluding framing bits but including FCS
octets) and had either a bad Frame Check Sequence (FCS) with
an integral number of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error)."
::= { pvxL2IFCrntPMEntry 83 }
pvxL2IFCrntPMFRGTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of received packet
fragments."
::= { pvxL2IFCrntPMEntry 84 }
pvxL2IFCrntPMFRGTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of received
packet fragments."
::= { pvxL2IFCrntPMEntry 85 }
pvxL2IFCrntPMFRGTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFCrntPMFRGTValue
object to 0."
::= { pvxL2IFCrntPMEntry 86 }
-- { pvxL2IFCrntPMEntry 87 } DELETED
-- { pvxL2IFCrntPMEntry 88 } DELETED
-- { pvxL2IFCrntPMEntry 89 } DELETED
-- { pvxL2IFCrntPMEntry 90 } DELETED
-----------------------------------------------------------------------
-- Objects used to retrieve historical Ethernet Layer 2
-- Performance Monitoring statistics for PacketVX Interfaces
-----------------------------------------------------------------------
pvxL2IFHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF PvxL2IFHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the PacketVX Layer2 interfaces on the NE."
::= { performance 30 }
pvxL2IFHistPMEntry OBJECT-TYPE
SYNTAX PvxL2IFHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the PacketVX Layer 2 historical
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a historical
measurement interval for a given PVX Layer 2 interface
facility."
INDEX { pvxL2IFHistPMSwitchIdx,
pvxL2IFHistPMShelfIdx,
pvxL2IFHistPMSlotIdx,
pvxL2IFHistPMPortTypeIdx,
pvxL2IFHistPMPortIdx,
pvxL2IFHistPMIntervalTypeIdx,
pvxL2IFHistPMIntervalIdx }
::= { pvxL2IFHistPMTable 1 }
PvxL2IFHistPMEntry ::= SEQUENCE { pvxL2IFHistPMSwitchIdx INTEGER,
pvxL2IFHistPMShelfIdx INTEGER,
pvxL2IFHistPMSlotIdx INTEGER,
pvxL2IFHistPMPortTypeIdx PvxPortType,
pvxL2IFHistPMPortIdx INTEGER,
pvxL2IFHistPMIntervalTypeIdx PMIntervalType,
pvxL2IFHistPMIntervalIdx INTEGER,
pvxL2IFHistPMTFRCRXValue Unsigned64,
pvxL2IFHistPMTFRCRXTimeStamp DateAndTime,
pvxL2IFHistPMTFRCRXValidity PMValidity,
pvxL2IFHistPMTFRCRXInitialize InitializeCmd,
pvxL2IFHistPMTFRCTXValue Unsigned64,
pvxL2IFHistPMTFRCTXTimeStamp DateAndTime,
pvxL2IFHistPMTFRCTXValidity PMValidity,
pvxL2IFHistPMTFRCTXInitialize InitializeCmd,
pvxL2IFHistPMFRDRValue Unsigned32,
pvxL2IFHistPMFRDRTimeStamp DateAndTime,
pvxL2IFHistPMFRDRValidity PMValidity,
pvxL2IFHistPMFRDRInitialize InitializeCmd,
pvxL2IFHistPMFCSEValue Unsigned32,
pvxL2IFHistPMFCSETimeStamp DateAndTime,
pvxL2IFHistPMFCSEValidity PMValidity,
pvxL2IFHistPMFCSEInitialize InitializeCmd,
pvxL2IFHistPMTBYCRXValue Unsigned64,
pvxL2IFHistPMTBYCRXTimeStamp DateAndTime,
pvxL2IFHistPMTBYCRXValidity PMValidity,
pvxL2IFHistPMTBYCRXInitialize InitializeCmd,
pvxL2IFHistPMTBYCTXValue Unsigned64,
pvxL2IFHistPMTBYCTXTimeStamp DateAndTime,
pvxL2IFHistPMTBYCTXValidity PMValidity,
pvxL2IFHistPMTBYCTXInitialize InitializeCmd,
pvxL2IFHistPMBCSTValue Unsigned64,
pvxL2IFHistPMBCSTTimeStamp DateAndTime,
pvxL2IFHistPMBCSTValidity PMValidity,
pvxL2IFHistPMBCSTInitialize InitializeCmd,
pvxL2IFHistPMMCSTValue Unsigned64,
pvxL2IFHistPMMCSTTimeStamp DateAndTime,
pvxL2IFHistPMMCSTValidity PMValidity,
pvxL2IFHistPMMCSTInitialize InitializeCmd,
pvxL2IFHistPMSIZE64Value Unsigned64,
pvxL2IFHistPMSIZE64TimeStamp DateAndTime,
pvxL2IFHistPMSIZE64Validity PMValidity,
pvxL2IFHistPMSIZE64Initialize InitializeCmd,
pvxL2IFHistPMSIZE65To127Value Unsigned64,
pvxL2IFHistPMSIZE65To127TimeStamp DateAndTime,
pvxL2IFHistPMSIZE65To127Validity PMValidity,
pvxL2IFHistPMSIZE65To127Initialize InitializeCmd,
pvxL2IFHistPMSIZE128To255Value Unsigned64,
pvxL2IFHistPMSIZE128To255TimeStamp DateAndTime,
pvxL2IFHistPMSIZE128To255Validity PMValidity,
pvxL2IFHistPMSIZE128To255Initialize InitializeCmd,
pvxL2IFHistPMSIZE256To511Value Unsigned64,
pvxL2IFHistPMSIZE256To511TimeStamp DateAndTime,
pvxL2IFHistPMSIZE256To511Validity PMValidity,
pvxL2IFHistPMSIZE256To511Initialize InitializeCmd,
pvxL2IFHistPMSIZE512To1023Value Unsigned64,
pvxL2IFHistPMSIZE512To1023TimeStamp DateAndTime,
pvxL2IFHistPMSIZE512To1023Validity PMValidity,
pvxL2IFHistPMSIZE512To1023Initialize InitializeCmd,
pvxL2IFHistPMSIZE1024To1518Value Unsigned64,
pvxL2IFHistPMSIZE1024To1518TimeStamp DateAndTime,
pvxL2IFHistPMSIZE1024To1518Validity PMValidity,
pvxL2IFHistPMSIZE1024To1518Initialize InitializeCmd,
pvxL2IFHistPMSIZEOver1518Value Unsigned64,
pvxL2IFHistPMSIZEOver1518TimeStamp DateAndTime,
pvxL2IFHistPMSIZEOver1518Validity PMValidity,
pvxL2IFHistPMSIZEOver1518Initialize InitializeCmd,
pvxL2IFHistPMTPFCRXValue Unsigned64,
pvxL2IFHistPMTPFCRXTimeStamp DateAndTime,
pvxL2IFHistPMTPFCRXValidity PMValidity,
pvxL2IFHistPMTPFCRXInitialize InitializeCmd,
pvxL2IFHistPMTPFCTXValue Unsigned64,
pvxL2IFHistPMTPFCTXTimeStamp DateAndTime,
pvxL2IFHistPMTPFCTXValidity PMValidity,
pvxL2IFHistPMTPFCTXInitialize InitializeCmd,
pvxL2IFHistPMUSIZEValue Unsigned32,
pvxL2IFHistPMUSIZETimeStamp DateAndTime,
pvxL2IFHistPMUSIZEValidity PMValidity,
pvxL2IFHistPMUSIZEInitialize InitializeCmd,
pvxL2IFHistPMOSIZEValue Unsigned32,
pvxL2IFHistPMOSIZETimeStamp DateAndTime,
pvxL2IFHistPMOSIZEValidity PMValidity,
pvxL2IFHistPMOSIZEInitialize InitializeCmd,
pvxL2IFHistPMFRGTValue Unsigned32,
pvxL2IFHistPMFRGTTimeStamp DateAndTime,
pvxL2IFHistPMFRGTValidity PMValidity,
pvxL2IFHistPMFRGTInitialize InitializeCmd}
pvxL2IFHistPMSwitchIdx OBJECT-TYPE
SYNTAX INTEGER(1..11)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The identifier of the ethernet switch instance on which the
Layer 2 Interface facilitiy is provisioned."
::= {pvxL2IFHistPMEntry 1 }
pvxL2IFHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the PVX Layer2 IF targeted
for PMs is provisioned. For LAG entities, the shelf number is 0."
::= { pvxL2IFHistPMEntry 2 }
pvxL2IFHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the PVX Layer2 IF targeted
for PMs is provisioned. For LAG entities, the slot number is 0."
::= { pvxL2IFHistPMEntry 3 }
pvxL2IFHistPMPortTypeIdx OBJECT-TYPE
SYNTAX PvxPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PacketVX port on which the Layer 2 Interface
facility is provisioned."
::= { pvxL2IFHistPMEntry 4 }
pvxL2IFHistPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the identified type on which the PVX
Layer 2 IF facility targeted for PMs is provisioned."
::= { pvxL2IFHistPMEntry 5 }
pvxL2IFHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { pvxL2IFHistPMEntry 6 }
pvxL2IFHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { pvxL2IFHistPMEntry 7 }
pvxL2IFHistPMTFRCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total received frame count receieved on the interface."
::= { pvxL2IFHistPMEntry 8 }
pvxL2IFHistPMTFRCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total received frame count
value."
::= { pvxL2IFHistPMEntry 9 }
pvxL2IFHistPMTFRCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided total received frame
count value."
::= { pvxL2IFHistPMEntry 10 }
pvxL2IFHistPMTFRCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMTFRCRXValue
object to 0."
::= { pvxL2IFHistPMEntry 11 }
pvxL2IFHistPMTFRCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total transmitted frame count on the interface."
::= { pvxL2IFHistPMEntry 12 }
pvxL2IFHistPMTFRCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total transmitted frame count
value."
::= { pvxL2IFHistPMEntry 13 }
pvxL2IFHistPMTFRCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided total transmitted frame
count value."
::= { pvxL2IFHistPMEntry 14 }
pvxL2IFHistPMTFRCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMTFRCTXValue
object to 0."
::= { pvxL2IFHistPMEntry 15 }
pvxL2IFHistPMFRDRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of discarded frames on the interface."
::= { pvxL2IFHistPMEntry 16 }
pvxL2IFHistPMFRDRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the discarded frames value."
::= { pvxL2IFHistPMEntry 17 }
pvxL2IFHistPMFRDRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided discarded frames
value."
::= { pvxL2IFHistPMEntry 18 }
pvxL2IFHistPMFRDRInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMFRDRValue
object to 0."
::= { pvxL2IFHistPMEntry 19 }
pvxL2IFHistPMFCSEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The count of frame checksum errors on the interface."
::= { pvxL2IFHistPMEntry 20 }
pvxL2IFHistPMFCSETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the frame checksum errors value."
::= { pvxL2IFHistPMEntry 21 }
pvxL2IFHistPMFCSEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided frame checksum errors
value."
::= { pvxL2IFHistPMEntry 22 }
pvxL2IFHistPMFCSEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMFCSEValue
object to 0."
::= { pvxL2IFHistPMEntry 23 }
pvxL2IFHistPMTBYCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total received byte count on the interface."
::= { pvxL2IFHistPMEntry 24 }
pvxL2IFHistPMTBYCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total received byte count
value."
::= { pvxL2IFHistPMEntry 25 }
pvxL2IFHistPMTBYCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided total received byte
count value."
::= { pvxL2IFHistPMEntry 26 }
pvxL2IFHistPMTBYCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMTBYCRXValue
object to 0."
::= { pvxL2IFHistPMEntry 27 }
pvxL2IFHistPMTBYCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total transmitted byte count on the interface."
::= { pvxL2IFHistPMEntry 28 }
pvxL2IFHistPMTBYCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total transmitted byte count
value."
::= { pvxL2IFHistPMEntry 29 }
pvxL2IFHistPMTBYCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided Ftotal transmitted byte
count value."
::= { pvxL2IFHistPMEntry 30 }
pvxL2IFHistPMTBYCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMTBYCTXValue
object to 0."
::= { pvxL2IFHistPMEntry 31 }
pvxL2IFHistPMBCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
the broadcast address. Note that this does not include
multicast frames."
::= { pvxL2IFHistPMEntry 32 }
pvxL2IFHistPMBCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the broadcast packets received
count value."
::= { pvxL2IFHistPMEntry 33 }
pvxL2IFHistPMBCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided broadcast packets
received count value."
::= { pvxL2IFHistPMEntry 34 }
pvxL2IFHistPMBCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMBCSTValue
object to 0."
::= { pvxL2IFHistPMEntry 35 }
pvxL2IFHistPMMCSTValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of good frames received that were directed to
a multicast address. Note that this number does not include
frames directed to the broadcast address."
::= { pvxL2IFHistPMEntry 36 }
pvxL2IFHistPMMCSTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the multicast packets received
count value."
::= { pvxL2IFHistPMEntry 37 }
pvxL2IFHistPMMCSTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided multicast packets
received count value."
::= { pvxL2IFHistPMEntry 38 }
pvxL2IFHistPMMCSTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMMCSTValue
object to 0."
::= { pvxL2IFHistPMEntry 39 }
pvxL2IFHistPMSIZE64Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of 64 byte frames received (excluding framing
bits but including FCS octets)."
::= { pvxL2IFHistPMEntry 40 }
pvxL2IFHistPMSIZE64TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of 64-byte packets
received."
::= { pvxL2IFHistPMEntry 41 }
pvxL2IFHistPMSIZE64Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of 64-byte
packets packets received."
::= { pvxL2IFHistPMEntry 42 }
pvxL2IFHistPMSIZE64Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMSIZE64Value
object to 0."
::= { pvxL2IFHistPMEntry 43 }
pvxL2IFHistPMSIZE65To127Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 65 to 127 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { pvxL2IFHistPMEntry 44 }
pvxL2IFHistPMSIZE65To127TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 65 and
127 bytes."
::= { pvxL2IFHistPMEntry 45 }
pvxL2IFHistPMSIZE65To127Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 65 and 127 bytes."
::= { pvxL2IFHistPMEntry 46 }
pvxL2IFHistPMSIZE65To127Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFHistPMSIZE65To127Value object to 0."
::= { pvxL2IFHistPMEntry 47 }
pvxL2IFHistPMSIZE128To255Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 128 to 255 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { pvxL2IFHistPMEntry 48 }
pvxL2IFHistPMSIZE128To255TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 128
and 255 bytes."
::= { pvxL2IFHistPMEntry 49 }
pvxL2IFHistPMSIZE128To255Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 128 and 255 bytes."
::= { pvxL2IFHistPMEntry 50 }
pvxL2IFHistPMSIZE128To255Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFHistPMSIZE128To255Value object to 0."
::= { pvxL2IFHistPMEntry 51 }
pvxL2IFHistPMSIZE256To511Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 256 to 511 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { pvxL2IFHistPMEntry 52 }
pvxL2IFHistPMSIZE256To511TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 256
and 511 bytes."
::= { pvxL2IFHistPMEntry 53 }
pvxL2IFHistPMSIZE256To511Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 256 and 511 bytes."
::= { pvxL2IFHistPMEntry 54 }
pvxL2IFHistPMSIZE256To511Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFHistPMSIZE256To511Value object to 0."
::= { pvxL2IFHistPMEntry 55 }
pvxL2IFHistPMSIZE512To1023Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 512 to 1023 bytes
inclusive in length (excluding framing bits but including FCS
octets)."
::= { pvxL2IFHistPMEntry 56 }
pvxL2IFHistPMSIZE512To1023TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 512
and 1023 bytes."
::= { pvxL2IFHistPMEntry 57 }
pvxL2IFHistPMSIZE512To1023Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 512 and 1023 bytes."
::= { pvxL2IFHistPMEntry 58 }
pvxL2IFHistPMSIZE512To1023Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFHistPMSIZE512To1023Value object to 0."
::= { pvxL2IFHistPMEntry 59 }
pvxL2IFHistPMSIZE1024To1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are 1024 to 1518
bytes inclusive in length (excluding framing bits but
including FCS octets)."
::= { pvxL2IFHistPMEntry 60 }
pvxL2IFHistPMSIZE1024To1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets between 1024
and 1518 bytes."
::= { pvxL2IFHistPMEntry 61 }
pvxL2IFHistPMSIZE1024To1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets
between 1024 and 1518 bytes."
::= { pvxL2IFHistPMEntry 62 }
pvxL2IFHistPMSIZE1024To1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFHistPMSIZE1024To1518Value object to 0."
::= { pvxL2IFHistPMEntry 63 }
pvxL2IFHistPMSIZEOver1518Value OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of frames received that are greater than or
equal to 1519 bytes in length (excluding framing bits but
including FCS octets)."
::= { pvxL2IFHistPMEntry 64 }
pvxL2IFHistPMSIZEOver1518TimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of packets over 1518
bytes."
::= { pvxL2IFHistPMEntry 65 }
pvxL2IFHistPMSIZEOver1518Validity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of packets over
1518 bytes."
::= { pvxL2IFHistPMEntry 66 }
pvxL2IFHistPMSIZEOver1518Initialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the
pvxL2IFHistPMSIZEOver1518Value object to 0."
::= { pvxL2IFHistPMEntry 67 }
pvxL2IFHistPMTPFCRXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total received pause frame count on the interface."
::= { pvxL2IFHistPMEntry 68 }
pvxL2IFHistPMTPFCRXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total received pause frame
count value."
::= { pvxL2IFHistPMEntry 69 }
pvxL2IFHistPMTPFCRXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided total received pause
frame count value."
::= { pvxL2IFHistPMEntry 70 }
pvxL2IFHistPMTPFCRXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMTPFCRXValue
object to 0."
::= { pvxL2IFHistPMEntry 71 }
pvxL2IFHistPMTPFCTXValue OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total transmitted pause frame count on the interface."
::= { pvxL2IFHistPMEntry 72 }
pvxL2IFHistPMTPFCTXTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the total transmitted pause frame
count value."
::= { pvxL2IFHistPMEntry 73 }
pvxL2IFHistPMTPFCTXValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided total transmitted pause
frame count value."
::= { pvxL2IFHistPMEntry 74 }
pvxL2IFHistPMTPFCTXInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMTPFCTXValue
object to 0."
::= { pvxL2IFHistPMEntry 75 }
pvxL2IFHistPMUSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets long (excluding framing bits, but including FCS octets)
and were otherwise well formed."
::= { pvxL2IFHistPMEntry 76 }
pvxL2IFHistPMUSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of undersized packets."
::= { pvxL2IFHistPMEntry 77 }
pvxL2IFHistPMUSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of undersized
packets."
::= { pvxL2IFHistPMEntry 78 }
pvxL2IFHistPMUSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMUSIZEValue
object to 0."
::= { pvxL2IFHistPMEntry 79 }
pvxL2IFHistPMOSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were longer than 9600
octets (excluding framing bits, but including FCS octets) and
were otherwise well formed."
::= { pvxL2IFHistPMEntry 80 }
pvxL2IFHistPMOSIZETimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of oversized packets."
::= { pvxL2IFHistPMEntry 81 }
pvxL2IFHistPMOSIZEValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of oversized
packets."
::= { pvxL2IFHistPMEntry 82 }
pvxL2IFHistPMOSIZEInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMOSIZEValue
object to 0."
::= { pvxL2IFHistPMEntry 83 }
pvxL2IFHistPMFRGTValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total number of frames received that were less than 64
octets in length (excluding framing bits but including FCS
octets) and had either a bad Frame Check Sequence (FCS) with
an integral number of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error)."
::= { pvxL2IFHistPMEntry 84 }
pvxL2IFHistPMFRGTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the count of received packet
fragments."
::= { pvxL2IFHistPMEntry 85 }
pvxL2IFHistPMFRGTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided count of received
packet fragments."
::= { pvxL2IFHistPMEntry 86 }
pvxL2IFHistPMFRGTInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the pvxL2IFHistPMFRGTValue
object to 0."
::= { pvxL2IFHistPMEntry 87 }
-- { pvxL2IFHistPMEntry 88 } DELETED
-- { pvxL2IFHistPMEntry 89 } DELETED
-- { pvxL2IFHistPMEntry 90 } DELETED
-- { pvxL2IFHistPMEntry 91 } DELETED
-----------------------------------------------------------------------
-- Objects used to manage configured Ethernet Layer 2
-- Performance Monitoring thresholds levels on PacketVX Interfaces
-----------------------------------------------------------------------
pvxL2IFPMThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF PvxL2IFPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of threshold levels for performance monitoring counter
values on PVX Layer 2 IF facilities, that are used in the
generation of threshold crossing alerts."
::= { performance 31 }
pvxL2IFPMThresholdEntry OBJECT-TYPE
SYNTAX PvxL2IFPMThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the PacketVX Layer 2 Interface
performance monitoring threshold table. Each row of this table
contains a set of PM thresholds for a given interval type that
applies to an individual PVX Layer 2 IF facility."
INDEX { pvxL2IFPMThresholdSwitchIdx,
pvxL2IFPMThresholdShelfIdx,
pvxL2IFPMThresholdSlotIdx,
pvxL2IFPMThresholdPortTypeIdx,
pvxL2IFPMThresholdPortIdx,
pvxL2IFPMThresholdIntervalTypeIdx }
::= { pvxL2IFPMThresholdTable 1 }
PvxL2IFPMThresholdEntry ::= SEQUENCE { pvxL2IFPMThresholdSwitchIdx INTEGER,
pvxL2IFPMThresholdShelfIdx INTEGER,
pvxL2IFPMThresholdSlotIdx INTEGER,
pvxL2IFPMThresholdPortTypeIdx PvxPortType,
pvxL2IFPMThresholdPortIdx INTEGER,
pvxL2IFPMThresholdIntervalTypeIdx PMIntervalType,
pvxL2IFPMThresholdFRDRValue Unsigned32,
pvxL2IFPMThresholdFCSEValue Unsigned32,
pvxL2IFPMThresholdUSIZEValue Unsigned32,
pvxL2IFPMThresholdOSIZEValue Unsigned32,
pvxL2IFPMThresholdFRGTValue Unsigned32}
pvxL2IFPMThresholdSwitchIdx OBJECT-TYPE
SYNTAX INTEGER(1..11)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The identifier of the ethernet switch instance on which the
Layer 2 Interface facilitiy is provisioned."
::= {pvxL2IFPMThresholdEntry 1 }
pvxL2IFPMThresholdShelfIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the PVX Layer2 IF targeted
for PM thresholds is provisioned. For LAG entities, the shelf number is 0."
::= { pvxL2IFPMThresholdEntry 2 }
pvxL2IFPMThresholdSlotIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the PVX Layer2 IF targeted
for PM thresholds is provisioned. For LAG entities, the slot number is 0."
::= { pvxL2IFPMThresholdEntry 3 }
pvxL2IFPMThresholdPortTypeIdx OBJECT-TYPE
SYNTAX PvxPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PacketVX port on which the Layer 2 Interface
facility is provisioned."
::= { pvxL2IFPMThresholdEntry 4 }
pvxL2IFPMThresholdPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the identified type on which the PVX
Layer 2 IF facility targeted for PM thresholds is
provisioned."
::= { pvxL2IFPMThresholdEntry 5 }
pvxL2IFPMThresholdIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { pvxL2IFPMThresholdEntry 6 }
pvxL2IFPMThresholdFRDRValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of discarded frames on the
interface."
::= { pvxL2IFPMThresholdEntry 7 }
pvxL2IFPMThresholdFCSEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of frame checksum errors on the
interface."
::= { pvxL2IFPMThresholdEntry 8 }
pvxL2IFPMThresholdUSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of undersized frames."
::= { pvxL2IFPMThresholdEntry 9 }
pvxL2IFPMThresholdOSIZEValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of oversized frames."
::= { pvxL2IFPMThresholdEntry 10 }
pvxL2IFPMThresholdFRGTValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The threshold for the count of fragmented frames."
::= { pvxL2IFPMThresholdEntry 11 }
-- { pvxL2IFPMThresholdEntry 12 } DELETED
-----------------------------------------------------------------------
-- Objects used to retrieve current Bit Rate Independent (BRI) port
-- Performance Monitoring statistics
-----------------------------------------------------------------------
briCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF BriCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the Bit Rate Independent (BRI) facilities on the NE."
::= { performance 38 }
briCrntPMEntry OBJECT-TYPE
SYNTAX BriCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the BRI current performance
monitoring table. Each row of this table contains a full set
of PM statistics and related data for a current measurement
interval for a given BRI facility."
INDEX { briCrntPMShelfIdx,
briCrntPMSlotIdx,
briCrntPMPortIdx,
briCrntPMIntervalTypeIdx }
::= { briCrntPMTable 1 }
BriCrntPMEntry ::= SEQUENCE { briCrntPMShelfIdx INTEGER,
briCrntPMSlotIdx INTEGER,
briCrntPMPortIdx INTEGER,
briCrntPMIntervalTypeIdx PMIntervalType,
briCrntPMOPRValue FixedX10,
briCrntPMOPRTimeStamp DateAndTime,
briCrntPMOPRValidity PMValidity,
briCrntPMOPTValue FixedX10,
briCrntPMOPTTimeStamp DateAndTime,
briCrntPMOPTValidity PMValidity,
briCrntPMTempValue INTEGER,
briCrntPMTempTimeStamp DateAndTime,
briCrntPMTempValidity PMValidity,
briCrntPMSupplyVoltageValue FixedX10,
briCrntPMSupplyVoltageTimeStamp DateAndTime,
briCrntPMSupplyVoltageValidity PMValidity,
briCrntPMLBCValue INTEGER,
briCrntPMLBCTimeStamp DateAndTime,
briCrntPMLBCValidity PMValidity,
briCrntPMOPRMinValue FixedX10,
briCrntPMOPRMinTimeStamp DateAndTime,
briCrntPMOPRMinValidity PMValidity,
briCrntPMOPRMinInitialize InitializeCmd,
briCrntPMOPRMaxValue FixedX10,
briCrntPMOPRMaxTimeStamp DateAndTime,
briCrntPMOPRMaxValidity PMValidity,
briCrntPMOPRMaxInitialize InitializeCmd,
briCrntPMOPRAvgValue FixedX10,
briCrntPMOPRAvgTimeStamp DateAndTime,
briCrntPMOPRAvgValidity PMValidity,
briCrntPMOPRAvgInitialize InitializeCmd,
briCrntPMOPTMinValue FixedX10,
briCrntPMOPTMinTimeStamp DateAndTime,
briCrntPMOPTMinValidity PMValidity,
briCrntPMOPTMinInitialize InitializeCmd,
briCrntPMOPTMaxValue FixedX10,
briCrntPMOPTMaxTimeStamp DateAndTime,
briCrntPMOPTMaxValidity PMValidity,
briCrntPMOPTMaxInitialize InitializeCmd,
briCrntPMOPTAvgValue FixedX10,
briCrntPMOPTAvgTimeStamp DateAndTime,
briCrntPMOPTAvgValidity PMValidity,
briCrntPMOPTAvgInitialize InitializeCmd }
briCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the BRI facility targeted for
PMs is provisioned."
::= { briCrntPMEntry 1 }
briCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the BRI facility targeted
for PMs is provisioned."
::= { briCrntPMEntry 2 }
briCrntPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the BRI
facility targeted for PMs is provisioned."
::= { briCrntPMEntry 3 }
briCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of BRI bin according to interval length."
::= { briCrntPMEntry 4 }
briCrntPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the BRI facility
port."
::= { briCrntPMEntry 5 }
briCrntPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { briCrntPMEntry 6 }
briCrntPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { briCrntPMEntry 7 }
briCrntPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the BRI facility
port."
::= { briCrntPMEntry 8 }
briCrntPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { briCrntPMEntry 9 }
briCrntPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { briCrntPMEntry 10 }
briCrntPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the BRI facility port."
::= { briCrntPMEntry 11 }
briCrntPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { briCrntPMEntry 12 }
briCrntPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { briCrntPMEntry 13 }
briCrntPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the BRI facility port."
::= { briCrntPMEntry 14 }
briCrntPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { briCrntPMEntry 15 }
briCrntPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { briCrntPMEntry 16 }
briCrntPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the BRI facility port."
::= { briCrntPMEntry 17 }
briCrntPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { briCrntPMEntry 18 }
briCrntPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { briCrntPMEntry 19 }
briCrntPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { briCrntPMEntry 20 }
briCrntPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { briCrntPMEntry 21 }
briCrntPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { briCrntPMEntry 22 }
briCrntPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briCrntPMOPRMinValue
object to 0."
::= { briCrntPMEntry 23 }
briCrntPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { briCrntPMEntry 24 }
briCrntPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { briCrntPMEntry 25 }
briCrntPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { briCrntPMEntry 26 }
briCrntPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briCrntPMOPRMaxValue
object to 0."
::= { briCrntPMEntry 27 }
briCrntPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { briCrntPMEntry 28 }
briCrntPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { briCrntPMEntry 29 }
briCrntPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { briCrntPMEntry 30 }
briCrntPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briCrntPMOPRAvgValue
object to 0."
::= { briCrntPMEntry 31 }
briCrntPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { briCrntPMEntry 32 }
briCrntPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { briCrntPMEntry 33 }
briCrntPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { briCrntPMEntry 34 }
briCrntPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briCrntPMOPTMinValue
object to 0."
::= { briCrntPMEntry 35 }
briCrntPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { briCrntPMEntry 36 }
briCrntPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { briCrntPMEntry 37 }
briCrntPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { briCrntPMEntry 38 }
briCrntPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briCrntPMOPTMaxValue
object to 0."
::= { briCrntPMEntry 39 }
briCrntPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { briCrntPMEntry 40 }
briCrntPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { briCrntPMEntry 41 }
briCrntPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { briCrntPMEntry 42 }
briCrntPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briCrntPMOPTAvgValue
object to 0."
::= { briCrntPMEntry 43 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical Bit Rate Independent (BRI) port
-- Performance Monitoring statistics
-----------------------------------------------------------------------
briHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF BriHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the Bit Rate Independent (BRI) facilities
on the NE."
::= { performance 39 }
briHistPMEntry OBJECT-TYPE
SYNTAX BriHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the BRI historical
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a historical
measurement interval for a given BRI facility."
INDEX { briHistPMShelfIdx,
briHistPMSlotIdx,
briHistPMPortIdx,
briHistPMIntervalTypeIdx,
briHistPMIntervalIdx }
::= { briHistPMTable 1 }
BriHistPMEntry ::= SEQUENCE { briHistPMShelfIdx INTEGER,
briHistPMSlotIdx INTEGER,
briHistPMPortIdx INTEGER,
briHistPMIntervalTypeIdx PMIntervalType,
briHistPMIntervalIdx INTEGER,
briHistPMOPRValue FixedX10,
briHistPMOPRTimeStamp DateAndTime,
briHistPMOPRValidity PMValidity,
briHistPMOPTValue FixedX10,
briHistPMOPTTimeStamp DateAndTime,
briHistPMOPTValidity PMValidity,
briHistPMTempValue INTEGER,
briHistPMTempTimeStamp DateAndTime,
briHistPMTempValidity PMValidity,
briHistPMSupplyVoltageValue FixedX10,
briHistPMSupplyVoltageTimeStamp DateAndTime,
briHistPMSupplyVoltageValidity PMValidity,
briHistPMLBCValue INTEGER,
briHistPMLBCTimeStamp DateAndTime,
briHistPMLBCValidity PMValidity,
briHistPMOPRMinValue FixedX10,
briHistPMOPRMinTimeStamp DateAndTime,
briHistPMOPRMinValidity PMValidity,
briHistPMOPRMinInitialize InitializeCmd,
briHistPMOPRMaxValue FixedX10,
briHistPMOPRMaxTimeStamp DateAndTime,
briHistPMOPRMaxValidity PMValidity,
briHistPMOPRMaxInitialize InitializeCmd,
briHistPMOPRAvgValue FixedX10,
briHistPMOPRAvgTimeStamp DateAndTime,
briHistPMOPRAvgValidity PMValidity,
briHistPMOPRAvgInitialize InitializeCmd,
briHistPMOPTMinValue FixedX10,
briHistPMOPTMinTimeStamp DateAndTime,
briHistPMOPTMinValidity PMValidity,
briHistPMOPTMinInitialize InitializeCmd,
briHistPMOPTMaxValue FixedX10,
briHistPMOPTMaxTimeStamp DateAndTime,
briHistPMOPTMaxValidity PMValidity,
briHistPMOPTMaxInitialize InitializeCmd,
briHistPMOPTAvgValue FixedX10,
briHistPMOPTAvgTimeStamp DateAndTime,
briHistPMOPTAvgValidity PMValidity,
briHistPMOPTAvgInitialize InitializeCmd }
briHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the BRI facility targeted for
PMs is provisioned."
::= { briHistPMEntry 1 }
briHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the BRI facility targeted
for PMs is provisioned."
::= { briHistPMEntry 2 }
briHistPMPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the BRI
facility targeted for PMs is provisioned."
::= { briHistPMEntry 3 }
briHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { briHistPMEntry 4 }
briHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1."
::= { briHistPMEntry 5 }
briHistPMOPRValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power received on the input of the BRI facility
port."
::= { briHistPMEntry 6 }
briHistPMOPRTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power received value."
::= { briHistPMEntry 7 }
briHistPMOPRValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power received
value."
::= { briHistPMEntry 8 }
briHistPMOPTValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The optical power transmitted at the output of the BRI facility
port."
::= { briHistPMEntry 9 }
briHistPMOPTTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the optical power transmitted
value."
::= { briHistPMEntry 10 }
briHistPMOPTValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided optical power
transmitted value."
::= { briHistPMEntry 11 }
briHistPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The temperature measured on the BRI facility port."
::= { briHistPMEntry 12 }
briHistPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { briHistPMEntry 13 }
briHistPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature value."
::= { briHistPMEntry 14 }
briHistPMSupplyVoltageValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "mVolts/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supply voltage measured on the BRI facility port."
::= { briHistPMEntry 15 }
briHistPMSupplyVoltageTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the supply voltage value."
::= { briHistPMEntry 16 }
briHistPMSupplyVoltageValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided supply voltage value."
::= { briHistPMEntry 17 }
briHistPMLBCValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "mAmp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The laser bias current measured on the BRI facility port."
::= { briHistPMEntry 18 }
briHistPMLBCTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the laser bias current value."
::= { briHistPMEntry 19 }
briHistPMLBCValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided laser bias current
value."
::= { briHistPMEntry 20 }
briHistPMOPRMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power received on the input of the transceiver."
::= { briHistPMEntry 21 }
briHistPMOPRMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power received value."
::= { briHistPMEntry 22 }
briHistPMOPRMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power received
value."
::= { briHistPMEntry 23 }
briHistPMOPRMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briHistPMOPRMinValue
object to 0."
::= { briHistPMEntry 24 }
briHistPMOPRMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power received on the input of the transceiver."
::= { briHistPMEntry 25 }
briHistPMOPRMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power received value."
::= { briHistPMEntry 26 }
briHistPMOPRMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power received
value."
::= { briHistPMEntry 27 }
briHistPMOPRMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briHistPMOPRMaxValue
object to 0."
::= { briHistPMEntry 28 }
briHistPMOPRAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power received on the input of the transceiver."
::= { briHistPMEntry 29 }
briHistPMOPRAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power received value."
::= { briHistPMEntry 30 }
briHistPMOPRAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power received
value."
::= { briHistPMEntry 31 }
briHistPMOPRAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briHistPMOPRAvgValue
object to 0."
::= { briHistPMEntry 32 }
briHistPMOPTMinValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum optical power transmitted at the output of the
transceiver."
::= { briHistPMEntry 33 }
briHistPMOPTMinTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the minimum optical power transmitted
value."
::= { briHistPMEntry 34 }
briHistPMOPTMinValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided minimum optical power
transmitted value."
::= { briHistPMEntry 35 }
briHistPMOPTMinInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briHistPMOPTMinValue
object to 0."
::= { briHistPMEntry 36 }
briHistPMOPTMaxValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum optical power transmitted at the output of the
transceiver."
::= { briHistPMEntry 37 }
briHistPMOPTMaxTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the maximum optical power transmitted
value."
::= { briHistPMEntry 38 }
briHistPMOPTMaxValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided maximum optical power
transmitted value."
::= { briHistPMEntry 39 }
briHistPMOPTMaxInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briHistPMOPTMaxValue
object to 0."
::= { briHistPMEntry 40 }
briHistPMOPTAvgValue OBJECT-TYPE
SYNTAX FixedX10
UNITS "dBm/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average optical power transmitted at the output of the
transceiver."
::= { briHistPMEntry 41 }
briHistPMOPTAvgTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the average optical power transmitted
value."
::= { briHistPMEntry 42 }
briHistPMOPTAvgValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided average optical power
transmitted value."
::= { briHistPMEntry 43 }
briHistPMOPTAvgInitialize OBJECT-TYPE
SYNTAX InitializeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to initialize the value of the briHistPMOPTAvgValue
object to 0."
::= { briHistPMEntry 44 }
-----------------------------------------------------------------------
-- Objects used to retrieve current provisioned circuit pack
-- Performance Monitoring statistics
-----------------------------------------------------------------------
cpCrntPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of current performance monitoring statistics collected
for the circuit packs on the NE."
::= { performance 49 }
cpCrntPMEntry OBJECT-TYPE
SYNTAX CpCrntPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the equipment current
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a current
measurement interval for a given circuit pack."
INDEX { cpCrntPMCpTypeIdx,
cpCrntPMShelfIdx,
cpCrntPMSlotIdx,
cpCrntPMIntervalTypeIdx }
::= { cpCrntPMTable 1 }
CpCrntPMEntry ::= SEQUENCE { cpCrntPMCpTypeIdx CpType,
cpCrntPMShelfIdx INTEGER,
cpCrntPMSlotIdx INTEGER,
cpCrntPMIntervalTypeIdx PMIntervalType,
cpCrntPMTempValue INTEGER,
cpCrntPMTempTimeStamp DateAndTime,
cpCrntPMTempValidity PMValidity }
cpCrntPMCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the circuit pack targeted for PM retrieval."
::= { cpCrntPMEntry 1 }
cpCrntPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the circuit pack targeted for
PMs is provisioned."
::= { cpCrntPMEntry 2 }
cpCrntPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the circuit pack
targeted for PMs is provisioned."
::= { cpCrntPMEntry 3 }
cpCrntPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { cpCrntPMEntry 4 }
cpCrntPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The circuit pack temperature."
::= { cpCrntPMEntry 5 }
cpCrntPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { cpCrntPMEntry 6 }
cpCrntPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature
value."
::= { cpCrntPMEntry 7 }
-----------------------------------------------------------------------
-- Objects used to retrieve historical provisioned circuit pack
-- Performance Monitoring statistics
-----------------------------------------------------------------------
cpHistPMTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of historical performance monitoring statistics
collected for the circuit packs on the NE."
::= { performance 50 }
cpHistPMEntry OBJECT-TYPE
SYNTAX CpHistPMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The row entry object of the circuit pack historical
performance monitoring table. Each row of this table contains
a full set of PM statistics and related data for a historical
measurement interval for a given circuit pack."
INDEX { cpHistPMCpTypeIdx,
cpHistPMShelfIdx,
cpHistPMSlotIdx,
cpHistPMIntervalTypeIdx,
cpHistPMIntervalIdx }
::= { cpHistPMTable 1 }
CpHistPMEntry ::= SEQUENCE { cpHistPMCpTypeIdx CpType,
cpHistPMShelfIdx INTEGER,
cpHistPMSlotIdx INTEGER,
cpHistPMIntervalTypeIdx PMIntervalType,
cpHistPMIntervalIdx INTEGER,
cpHistPMTempValue INTEGER,
cpHistPMTempTimeStamp DateAndTime,
cpHistPMTempValidity PMValidity }
cpHistPMCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of the circuit pack targeted for PM retrieval."
::= { cpHistPMEntry 1 }
cpHistPMShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the circuit pack targeted for
PMs is provisioned."
::= { cpHistPMEntry 2 }
cpHistPMSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the circuit pack
targeted for PMs is provisioned."
::= { cpHistPMEntry 3 }
cpHistPMIntervalTypeIdx OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The type of PM bin according to interval length."
::= { cpHistPMEntry 4 }
cpHistPMIntervalIdx OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific PM bin number. The range is 1..96 for 15-minute
bins, and for 1-day historical bins, the value is 1."
::= { cpHistPMEntry 5 }
cpHistPMTempValue OBJECT-TYPE
SYNTAX INTEGER (-32768..32767)
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The circuit pack temperature."
::= { cpHistPMEntry 6 }
cpHistPMTempTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time stamp of the temperature value."
::= { cpHistPMEntry 7 }
cpHistPMTempValidity OBJECT-TYPE
SYNTAX PMValidity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the provided temperature
value."
::= { cpHistPMEntry 8 }
-----------------------------------------------------------------------
-- Objects related to GCC0
------------------------------------------------------------------------
gcc0ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gcc0ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of GCC0 configuration information.
This table contains one row for every provisioned GCC0."
::= { dataComms 4 }
gcc0ConfigEntry OBJECT-TYPE
SYNTAX Gcc0ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row that contains GCC0 configuration
information of an interface. Each instance must
correspond to an instance of an OTN Port
capable of supporting GCC.
Instances of this conceptual row persist across
agent restarts."
INDEX { gcc0ConfigCpTypeIdx,
gcc0ConfigShelfIdx,
gcc0ConfigSlotIdx,
gcc0ConfigPortIdx }
::= { gcc0ConfigTable 1 }
Gcc0ConfigEntry ::= SEQUENCE { gcc0ConfigCpTypeIdx CpType,
gcc0ConfigShelfIdx INTEGER,
gcc0ConfigSlotIdx INTEGER,
gcc0ConfigPortIdx INTEGER,
gcc0ConfigMode INTEGER,
gcc0ConfigAdminStatus AdminStatus,
gcc0ConfigOperStatus OperStatus,
gcc0ConfigOperStatQlfr OperStatQlfr,
gcc0ConfigRowStatus RowStatus }
gcc0ConfigCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of circuit pack provisioned."
::= { gcc0ConfigEntry 1 }
gcc0ConfigShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the gcc0 is provisioned."
::= { gcc0ConfigEntry 2 }
gcc0ConfigSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the gcc0 is provisioned."
::= { gcc0ConfigEntry 3 }
gcc0ConfigPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
gcc0 provisioned."
::= { gcc0ConfigEntry 4 }
gcc0ConfigMode OBJECT-TYPE
SYNTAX INTEGER { fullRate (1),
lowRate (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The desired mode to which the gcc0 is to be provisioned."
DEFVAL { fullRate }
::= { gcc0ConfigEntry 5 }
gcc0ConfigAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the gcc."
DEFVAL { enabled }
::= { gcc0ConfigEntry 6 }
gcc0ConfigOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the gcc."
::= { gcc0ConfigEntry 7 }
gcc0ConfigOperStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual list of qualifiers of the reported operational
status of the gcc."
::= { gcc0ConfigEntry 8 }
gcc0ConfigRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This columnar object is used for creating and deleting a
conceptual row of the gcc0 config table."
::= { gcc0ConfigEntry 9 }
-----------------------------------------------------------------------
-- IPExtInterface_Table
-----------------------------------------------------------------------
ipExtInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF IPExtInterfaceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { dataComms 5 }
ipExtInterfaceTableEntry OBJECT-TYPE
SYNTAX IPExtInterfaceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
pvxL2IntfSwitchIdx,
pvxL2IntfShelfIdx,
pvxL2IntfSlotIdx,
pvxL2IntfPortTypeIdx,
pvxL2IntfPortIdx,
pvxL2IntfSubPortNumber
}
::= { ipExtInterfaceTable 1 }
IPExtInterfaceTableEntry ::= SEQUENCE {
pvxL2IntfSubPortNumber Integer32,
ipExtIntfPrimaryState OperStatus,
ipExtIntfSecondaryState OperStatQlfr,
ipExtIntfCmdPrimaryState OperStatus,
ipExtIntfNumberedStatus TruthValue,
ipExtIntfAddressType InetAddressType,
ipExtIntfAddress InetAddress,
ipExtIntfSubnetMask InetAddress,
ipExtIntfProxyARPStatus TruthValue,
ipExtIntfDescription DisplayString,
ipExtIntfMACAddr MacAddress,
ipExtIntfOperStatus OperStatus,
ipExtIntfType INTEGER,
ipExtIntfBroadcastAddress InetAddress,
ipExtIntfSpeed Gauge32,
ipExtIntfMode DuplexModeType,
ipExtIntfMTUSize Integer32,
ipExtIntfLastChange Integer32,
ipExtIntfGateway InetAddress,
ipExtIntfRowStatus RowStatus }
pvxL2IntfSubPortNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A number indentifying a entity smaller than and contained
in a port. At this time, this value is unused and must be
zero."
::= { ipExtInterfaceTableEntry 1 }
ipExtIntfPrimaryState OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the IP Interface."
::= { ipExtInterfaceTableEntry 2 }
ipExtIntfSecondaryState OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual list of qualifiers for the reported operational
status of the IP Interface"
::= { ipExtInterfaceTableEntry 3 }
ipExtIntfCmdPrimaryState OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { ipExtInterfaceTableEntry 4 }
ipExtIntfNumberedStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Set to true if this is a numbered interface and false
if it is unnumbered."
::= { ipExtInterfaceTableEntry 5 }
ipExtIntfAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of addresses (v4/v6) used in this row of
this MIB. Currently only ipv4 is allowed in this table."
::= { ipExtInterfaceTableEntry 6 }
ipExtIntfAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP Address associated with the interface."
::= { ipExtInterfaceTableEntry 7 }
ipExtIntfSubnetMask OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The sub-net mask associated with the interface."
::= { ipExtInterfaceTableEntry 8 }
ipExtIntfProxyARPStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Not currently implemented."
::= { ipExtInterfaceTableEntry 9 }
ipExtIntfDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A string describing the interface."
::= { ipExtInterfaceTableEntry 10 }
ipExtIntfMACAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address associated with the interface, if
applicable. All zeros for a non-MAC interface."
::= { ipExtInterfaceTableEntry 11 }
ipExtIntfOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { ipExtInterfaceTableEntry 12 }
ipExtIntfType OBJECT-TYPE
SYNTAX INTEGER { optical (1),
electrical (2),
logical (3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value describing the type of interface."
::= { ipExtInterfaceTableEntry 13 }
ipExtIntfBroadcastAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The broadcast address associated with the interface."
::= { ipExtInterfaceTableEntry 14 }
ipExtIntfSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { ipExtInterfaceTableEntry 15 }
ipExtIntfMode OBJECT-TYPE
SYNTAX DuplexModeType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Is the interface full or half-duplex?"
::= { ipExtInterfaceTableEntry 16 }
ipExtIntfMTUSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Maximum Transmission Unit for the interface."
::= { ipExtInterfaceTableEntry 17 }
ipExtIntfLastChange OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { ipExtInterfaceTableEntry 18 }
ipExtIntfGateway OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The gateway IP address associated with the interface."
::= { ipExtInterfaceTableEntry 19 }
ipExtIntfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This columnar object is used for creating and deleting a
conceptual row of the ipExtIntf table."
::= { ipExtInterfaceTableEntry 100 }
-----------------------------------------------------------------------
-- Scalar objects used to contain data transfered in
-- Trap OBJECTS
-----------------------------------------------------------------------
notifObjects OBJECT IDENTIFIER ::= { conditions 1 }
condDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This object is used in Trap messages to indicate the date and
time at which the condition or alarm reported in the Trap
message occurred."
::= { notifObjects 1 }
condReportType OBJECT-TYPE
SYNTAX CondReportType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates if this is a condition (non-alarmed) or an alarm.
This object is used solely for reporting the condition report
type in Trap messages."
::= { notifObjects 2 }
condSeverity OBJECT-TYPE
SYNTAX CondSeverity
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates the severity of the condition or alarm. This object
is used solely for reporting the condition severity in Trap
messages."
::= { notifObjects 3 }
condServiceAffecting OBJECT-TYPE
SYNTAX CondServiceAffecting
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates if the presence of this active condition or alarm
impacts the ability of the equipment to provide service as
expected. This object is used solely for reporting whether or
not a condition is service affecting in Trap messages."
::= { notifObjects 4 }
condDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "A textual decription of the condition or alarm. This object is
used solely for reporting the condition description in Trap
messages."
::= { notifObjects 5 }
condObjectType OBJECT-TYPE
SYNTAX NotifObjectType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Identifies the type of managed object against which the
condition or alarm is raised."
::= { notifObjects 6 }
condCodeType OBJECT-TYPE
SYNTAX NotifCodeType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This object value uniquely identifies the type of condition
or alarm that is raised."
::= { notifObjects 7 }
-----------------------------------------------------------------------
-- Information on standing conditions and alarms that are active on
-- the network element.
-----------------------------------------------------------------------
actCondTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActCondEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all active conditions and alarms raised on
the system."
::= { conditions 2 }
actCondEntry OBJECT-TYPE
SYNTAX ActCondEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains identifying and descriptive attributes for a single
active condition or alarm raised on the network element."
INDEX { actCondNotifIdx,
actCondTableEntryIdx,
actCondInstanceIdx }
::= { actCondTable 1 }
ActCondEntry ::= SEQUENCE { actCondNotifIdx OBJECT IDENTIFIER,
actCondTableEntryIdx OBJECT IDENTIFIER,
actCondInstanceIdx DisplayString,
actCondReportType CondReportType,
actCondDateAndTime DateAndTime,
actCondSeverity CondSeverity,
actCondServiceAffecting CondServiceAffecting,
actCondDescription DisplayString,
actCondObjectType NotifObjectType,
actCondCodeType NotifCodeType }
actCondNotifIdx OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies the type of condition or alarm that is active by
pointing to the NOTIFICATION-TYPE object that corresponds to
the raising event of the condition or alarm."
::= { actCondEntry 1 }
actCondTableEntryIdx OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies the type of resource that is alarmed by pointing to
the corresponding table entry object."
::= { actCondEntry 2 }
actCondInstanceIdx OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies the specific instance of the idenitifed resource
type that is alarmed by providing instance data that applies
to an instance of the table entry object type identified by
actCondTableEntryIdx. The instance data portion of the OID is
mapped to an OCTET string."
::= { actCondEntry 3 }
actCondReportType OBJECT-TYPE
SYNTAX CondReportType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if the table entry is a condition (non-alarmed) or
an alarm."
::= { actCondEntry 4 }
actCondDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time that the condition or alarm reported in the
trap message was raised."
::= { actCondEntry 5 }
actCondSeverity OBJECT-TYPE
SYNTAX CondSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates how severe the condition or alarm is."
::= { actCondEntry 6 }
actCondServiceAffecting OBJECT-TYPE
SYNTAX CondServiceAffecting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if the presence of this active condition or alarm
impacts the ability of the equipment to provide service as
expected."
::= { actCondEntry 7 }
actCondDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual decription of the condition or alarm."
::= { actCondEntry 8 }
actCondObjectType OBJECT-TYPE
SYNTAX NotifObjectType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifies the type of managed object against which the
condition or alarm is raised."
::= { actCondEntry 9 }
actCondCodeType OBJECT-TYPE
SYNTAX NotifCodeType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object value uniquely identifies the type of condition
or alarm that is raised."
::= { actCondEntry 10 }
actCondSummary OBJECT-TYPE
SYNTAX INTEGER { noActiveConditions (1),
nonAlarmedConditionsActive (2),
minorAlarmsActive (3),
majorAlarmsActive (4),
criticalAlarmsActive (5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object summarizes the active alarm/condition status of
the network element. The value of the object returned
indicates the following status data:
- noActiveConditions: there are no active alarms or conditions
on the network element
- nonAlarmedConditionsActive: there is one or more active
conditions on the network element, but none are of alarmable
severity
- minorAlarmsActive: there is one or more active conditions
and/or alarms on the network element, and the highest severity
level alarm is minor
- majorAlarmsActive: there is one or more active conditions
and/or alarms on the network element, and the highest severity
level alarm is major
- criticalAlarmsActive: there is one or more active conditions
and/or alarms on the network element, and the highest severity
level alarm is critical"
::= { conditions 3 }
-----------------------------------------------------------------------
-- Information on alarms that are active on
-- the network element.
-----------------------------------------------------------------------
actAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all active alarms raised on the system."
::= { conditions 4 }
actAlarmEntry OBJECT-TYPE
SYNTAX ActAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains identifying and descriptive attributes for a single
active alarm raised on the system."
INDEX { actAlarmNotifIdx,
actAlarmTableEntryIdx,
actAlarmInstanceIdx }
::= { actAlarmTable 1 }
ActAlarmEntry ::= SEQUENCE { actAlarmNotifIdx OBJECT IDENTIFIER,
actAlarmTableEntryIdx OBJECT IDENTIFIER,
actAlarmInstanceIdx DisplayString,
actAlarmReportType CondReportType,
actAlarmDateAndTime DateAndTime,
actAlarmSeverity CondSeverity,
actAlarmServiceAffecting CondServiceAffecting,
actAlarmDescription DisplayString,
actAlarmObjectType NotifObjectType,
actAlarmCodeType NotifCodeType }
actAlarmNotifIdx OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies the type of alarm that is active by pointing to the
NOTIFICATION-TYPE object that corresponds to the raising event
of the condition or alarm."
::= { actAlarmEntry 1 }
actAlarmTableEntryIdx OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies the type of resource that is alarmed by pointing to
the corresponding table entry object."
::= { actAlarmEntry 2 }
actAlarmInstanceIdx OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies the specific instance of the idenitifed resource
type that is alarmed by providing instance data that applies
to an instance of the table entry object type identified by
actAlarmTableEntryIdx. The instance data portion of the OID is
mapped to an OCTET string."
::= { actAlarmEntry 3 }
actAlarmReportType OBJECT-TYPE
SYNTAX CondReportType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if the table entry is an alarm."
::= { actAlarmEntry 4 }
actAlarmDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time that the alarm reported in the trap message
was raised."
::= { actAlarmEntry 5 }
actAlarmSeverity OBJECT-TYPE
SYNTAX CondSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates how severe the alarm is."
::= { actAlarmEntry 6 }
actAlarmServiceAffecting OBJECT-TYPE
SYNTAX CondServiceAffecting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if the presence of this active alarm impacts the
ability of the equipment to provide service as expected."
::= { actAlarmEntry 7 }
actAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual decription of the alarm."
::= { actAlarmEntry 8 }
actAlarmObjectType OBJECT-TYPE
SYNTAX NotifObjectType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifies the type of managed object against which the
alarm is raised."
::= { actAlarmEntry 9 }
actAlarmCodeType OBJECT-TYPE
SYNTAX NotifCodeType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object value uniquely identifies the type of
alarm that is raised."
::= { actAlarmEntry 10 }
-----------------------------------------------------------------------
-- Objects related to managing the TL1 Users
-- configured on the system.
-----------------------------------------------------------------------
tl1UserTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tl1UserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned user that
can operate the TL1 management interface on the NE. Each row
contains a list of attributes that pertain to a provisioned
TL1 user."
::= { administration 1 }
tl1UserEntry OBJECT-TYPE
SYNTAX Tl1UserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the TL1 user table."
INDEX { tl1UserIdx }
::= { tl1UserTable 1 }
Tl1UserEntry ::= SEQUENCE { tl1UserIdx DisplayString }
tl1UserIdx OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This is the unique user identifier, or UID, that is used for
TL1 access."
::= { tl1UserEntry 1 }
tl1IpLockoutAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..15))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This is an IP address from which TL1 user login attempts have
been temporarily disabled due to an excessive number of failed
user login attempts."
::= { administration 2 }
-----------------------------------------------------------------------
-- Objects related to retrieval of system logs generated by the TL1
-- management interface.
-----------------------------------------------------------------------
tl1LogTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tl1LogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists all the log entries generated by the TL1
interface on the BTI 7000 system."
::= { administration 3 }
tl1LogEntry OBJECT-TYPE
SYNTAX Tl1LogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the TL1 log table."
INDEX { tl1LogIdx }
::= { tl1LogTable 1 }
Tl1LogEntry ::= SEQUENCE { tl1LogIdx Unsigned32,
tl1LogSysName DisplayString,
tl1LogType INTEGER,
tl1LogTypeSpecificLogNum Unsigned32,
tl1LogMsgCode DisplayString,
tl1LogDateAndTime DateAndTime,
tl1LogMessage DisplayString }
tl1LogIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The unique identifier for this log entry. It is the global Log
Id of the entry when viewed through the TL1 interface."
::= { tl1LogEntry 1 }
tl1LogSysName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the BTI 7000 system at the time that the log was
recorded."
::= { tl1LogEntry 2 }
tl1LogType OBJECT-TYPE
SYNTAX INTEGER { alarm (1),
event (2),
dbChange (3),
security (4),
command (5),
rtrvcmd (6) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of log entry."
::= { tl1LogEntry 3 }
tl1LogTypeSpecificLogNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type-specific number for this log."
::= { tl1LogEntry 4 }
tl1LogMsgCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The message code that was issued for this log entry. This
field is relevant to log entries for TL1 autonomous
notifications. For example, the message code may be 'REPT ALM
OC48'. A message code is reported for all log entries of type
alarm, event and dbChange. For logs of type security or
command, the message code is an empty string."
::= { tl1LogEntry 5 }
tl1LogDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The timestamp of the log entry."
::= { tl1LogEntry 6 }
tl1LogMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the main log entry contents. The log entry is enclosed
in double quotations."
::= { tl1LogEntry 7 }
latestTl1LogNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifies the value of the tl1LogIdx object for the most recently
added entry in the tl1LogTable."
::= { administration 4 }
-----------------------------------------------------------------------
-- Objects related to managing the configured recipients of trap or
-- inform messages generated by the system's SNMP agent.
-----------------------------------------------------------------------
snmpTrapRcvTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnmpTrapRcvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every configured SNMP
trap receiver. Each row contains a list of attributes
that pertain to a provisioned trap receiver. All access to
this table, whether for read, write, or create requests
are restricted to SNMP requests issued with a valid
community string configured with read-write access."
::= { administration 5 }
snmpTrapRcvEntry OBJECT-TYPE
SYNTAX SnmpTrapRcvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the SNMP trap receiver table."
INDEX { snmpTrapRcvIdx }
::= { snmpTrapRcvTable 1 }
SnmpTrapRcvEntry ::= SEQUENCE { snmpTrapRcvIdx DisplayString,
snmpTrapRcvIPAddr IpAddress,
snmpTrapRcvPort INTEGER,
snmpTrapRcvNotifType INTEGER,
snmpTrapRcvVersion INTEGER,
snmpTrapRcvCommunity DisplayString,
snmpTrapRcvTTL HoursAndMinutes,
snmpTrapRcvRowStatus RowStatus }
snmpTrapRcvIdx OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This string serves as a unique trap receiver Id and is
used to index the table."
::= { snmpTrapRcvEntry 1 }
snmpTrapRcvIPAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The IP address of the trap receiver. The setting of this
object is mandatory when creating a new row."
::= { snmpTrapRcvEntry 2 }
snmpTrapRcvPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The port on the specified IP address of the trap receiver."
DEFVAL { 162 }
::= { snmpTrapRcvEntry 3 }
snmpTrapRcvNotifType OBJECT-TYPE
SYNTAX INTEGER { trap (1),
inform (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of notification service to be provided to the
trap receiver. The notification type can be configured
as inform only if the message version specified for the
snmpTrapRcvVersion object is snmpv2c."
DEFVAL { trap }
::= { snmpTrapRcvEntry 4 }
snmpTrapRcvVersion OBJECT-TYPE
SYNTAX INTEGER { snmpV1 (1),
snmpV2c (2),
snmpV3 (3) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of notification service to be provided to the
trap receiver. The notification type can be configured
as inform only if the message version specified for the
snmpTrapRcvVersion object is snmpv2c. The setting of this
object is mandatory when creating a new row."
::= { snmpTrapRcvEntry 5 }
snmpTrapRcvCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The community string inserted into the trap messages
generated for this trap receiver. The setting of this
object is mandatory when creating a new row."
::= { snmpTrapRcvEntry 6 }
snmpTrapRcvTTL OBJECT-TYPE
SYNTAX HoursAndMinutes
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The time-to-live for the trap receiver. When the trap
receiver is created or this object is set, this object
specifies how long the trap receiver is to be configured.
When read, the value returned is the length of time
remaining before the trap receiver is automatically
deleted. The valid range for this object is 000-00 to
099-99. If this object is set to a value of 000-00,
the trap receiver will never auto-delete."
DEFVAL { "000-00" }
::= { snmpTrapRcvEntry 7 }
snmpTrapRcvRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries
in the SNMP trap receiver table."
::= { snmpTrapRcvEntry 100 }
-----------------------------------------------------------------------
-- Objects related to cross connections between optical transceiver
-- facilities on wavelength conversion circuit packs
--
-- A listing of provisioned optical transceiver cross connects is
-- contained in the xcvrXCTable of the BTI 7000 Series MIB. When
-- retrieved, this table provides one row for each provisioned optical
-- transceiver cross connect between two transceiver end ports.
--
-- To create a cross connect, a new row of the xcvrXCTable must be
-- created. To delete a cross connect, the corresponding row of the
-- table must be destroyed.
-----------------------------------------------------------------------
xcvrXCTable OBJECT-TYPE
SYNTAX SEQUENCE OF XcvrXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned cross
connection between optical transceiver facilities on
wavelength translator, regenerator and manager circuit packs."
::= { connections 1 }
xcvrXCEntry OBJECT-TYPE
SYNTAX XcvrXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical transceiver cross
connection table."
INDEX { xcvrXCSrcTypeIdx,
xcvrXCSrcShelfIdx,
xcvrXCSrcSlotIdx,
xcvrXCSrcIdx,
xcvrXCDestTypeIdx,
xcvrXCDestShelfIdx,
xcvrXCDestSlotIdx,
xcvrXCDestIdx }
::= { xcvrXCTable 1 }
XcvrXCEntry ::= SEQUENCE { xcvrXCSrcTypeIdx XcvrType,
xcvrXCSrcShelfIdx INTEGER,
xcvrXCSrcSlotIdx INTEGER,
xcvrXCSrcIdx INTEGER,
xcvrXCDestTypeIdx XcvrType,
xcvrXCDestShelfIdx INTEGER,
xcvrXCDestSlotIdx INTEGER,
xcvrXCDestIdx INTEGER,
xcvrXCType XCType,
xcvrXCRowStatus RowStatus }
xcvrXCSrcTypeIdx OBJECT-TYPE
SYNTAX XcvrType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of wavelength conversion function of the
transceiver port that serves as the source port for the cross
connection."
::= { xcvrXCEntry 1 }
xcvrXCSrcShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the transceiver port that serves as
the source port for the cross connection."
::= { xcvrXCEntry 2 }
xcvrXCSrcSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the transceiver port that serves as
the source port for the cross connection."
::= { xcvrXCEntry 3 }
xcvrXCSrcIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the transceiver port that serves as
the source port for the cross connection."
::= { xcvrXCEntry 4 }
xcvrXCDestTypeIdx OBJECT-TYPE
SYNTAX XcvrType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of wavelength conversion function of the
transceiver port that serves as the destination port for the
cross connection."
::= { xcvrXCEntry 5 }
xcvrXCDestShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the transceiver port that serves as
the destination port for the cross connection."
::= { xcvrXCEntry 6 }
xcvrXCDestSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the transceiver port that serves as
the destination port for the cross connection."
::= { xcvrXCEntry 7 }
xcvrXCDestIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the transceiver port that serves as
the destination port for the cross connection."
::= { xcvrXCEntry 8 }
xcvrXCType OBJECT-TYPE
SYNTAX XCType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of cross connection between the identified source and
destination transceiver ports. This is a mandatory object when
a row of the transceiver cross connect table is created. Only
1-way and 2-way cross-connections are supported on optical
transceiver ports"
::= { xcvrXCEntry 9 }
xcvrXCRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
transceiver cross connection table, which in turn controls the
provisioning and de-provisioning of transceiver cross
connections."
::= { xcvrXCEntry 100 }
-----------------------------------------------------------------------
-- Objects related to cross connections between Virtual Concatenation
-- Group (VCG) entities on Muxponder circuit packs
--
-- A listing of provisioned virtual concatenation group (VCG) cross
-- connects is contained in the vcgXCTable of the BTI 7000 Series MIB.
-- VCG entities are created on the muxponder circuit pack to facilitate
-- the mapping of client facilities into line facility time slots. The
-- client facilities are transported over line facility time slots when
-- the required VCG cross-connects are created. When retrieved, this
-- table provides one row for each provisioned VCG cross connect.
--
-- To create a cross connect, a new row of the vcgXCTable must be
-- created. To delete a cross connect, the corresponding row of the
-- table must be destroyed.
-----------------------------------------------------------------------
vcgXCTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcgXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned cross
connection between VCGs on Muxponder circuit packs."
::= { connections 2 }
vcgXCEntry OBJECT-TYPE
SYNTAX VcgXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the VCG cross connection table."
INDEX { vcgXCSrcShelfIdx,
vcgXCSrcSlotIdx,
vcgXCSrcPortIdx,
vcgXCSrcIdx,
vcgXCDestShelfIdx,
vcgXCDestSlotIdx,
vcgXCDestPortIdx,
vcgXCDestIdx }
::= { vcgXCTable 1 }
VcgXCEntry ::= SEQUENCE { vcgXCSrcShelfIdx INTEGER,
vcgXCSrcSlotIdx INTEGER,
vcgXCSrcPortIdx INTEGER,
vcgXCSrcIdx INTEGER,
vcgXCDestShelfIdx INTEGER,
vcgXCDestSlotIdx INTEGER,
vcgXCDestPortIdx INTEGER,
vcgXCDestIdx INTEGER,
vcgXCType XCType,
vcgXCProtShelfNum INTEGER,
vcgXCProtSlotNum INTEGER,
vcgXCProtPortNum INTEGER,
vcgXCProtNum INTEGER,
vcgXCRowStatus RowStatus }
vcgXCSrcShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the VCG entity that serves as the
source port for the cross connection."
::= { vcgXCEntry 1 }
vcgXCSrcSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the VCG entity that serves as the
source port for the cross connection."
::= { vcgXCEntry 2 }
vcgXCSrcPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the VCG entity that serves as the
source port for the cross connection."
::= { vcgXCEntry 3 }
vcgXCSrcIdx OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the VCG within the identified port that serves
as the source port for the cross connection."
::= { vcgXCEntry 4 }
vcgXCDestShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the VCG entity that serves as the
destination port for the cross connection."
::= { vcgXCEntry 5 }
vcgXCDestSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the VCG entity that serves as the
destination port for the cross connection."
::= { vcgXCEntry 6 }
vcgXCDestPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the VCG entity that serves as the
destination port for the cross connection."
::= { vcgXCEntry 7 }
vcgXCDestIdx OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the VCG within the identified port that serves
as the destination port for the cross connection."
::= { vcgXCEntry 8 }
vcgXCType OBJECT-TYPE
SYNTAX XCType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of cross connection between the identified source and
destination VCG entities. This is a mandatory object when a
row of the VCG cross connect table is created. Only 2-way and
2-way protected cross-connections are supported between VCGs."
::= { vcgXCEntry 9 }
vcgXCProtShelfNum OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the shelf of the VCG entity that serves as the
protection port for the cross connection."
::= { vcgXCEntry 10 }
vcgXCProtSlotNum OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the slot of the VCG entity that serves as the
protection port for the cross connection."
::= { vcgXCEntry 11 }
vcgXCProtPortNum OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the port of the VCG entity that serves as the
protection port for the cross connection."
::= { vcgXCEntry 12 }
vcgXCProtNum OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the VCG within the identified port that serves
as the protection port for the cross connection."
::= { vcgXCEntry 13 }
vcgXCRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
VCG cross connection table, which in turn controls the
provisioning and de-provisioning of VCG cross connections."
::= { vcgXCEntry 100 }
-----------------------------------------------------------------------
-- Objects related to cross connections of SONET STS-N facilities
-- on Muxponder circuit packs
-----------------------------------------------------------------------
stsnXCTable OBJECT-TYPE
SYNTAX SEQUENCE OF StsnXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned cross
connection between SONET STS-N facilities on Muxponder circuit
packs."
::= { connections 3 }
stsnXCEntry OBJECT-TYPE
SYNTAX StsnXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the STS-N cross connection
table."
INDEX { stsnXCStsnTypeIdx,
stsnXCSrcShelfIdx,
stsnXCSrcSlotIdx,
stsnXCSrcPortIdx,
stsnXCSrcIdx,
stsnXCDestShelfIdx,
stsnXCDestSlotIdx,
stsnXCDestPortIdx,
stsnXCDestIdx }
::= { stsnXCTable 1 }
StsnXCEntry ::= SEQUENCE { stsnXCStsnTypeIdx StsnType,
stsnXCSrcShelfIdx INTEGER,
stsnXCSrcSlotIdx INTEGER,
stsnXCSrcPortIdx INTEGER,
stsnXCSrcIdx INTEGER,
stsnXCDestShelfIdx INTEGER,
stsnXCDestSlotIdx INTEGER,
stsnXCDestPortIdx INTEGER,
stsnXCDestIdx INTEGER,
stsnXCType XCType,
stsnXCProtTypeNum StsnType,
stsnXCProtShelfNum INTEGER,
stsnXCProtSlotNum INTEGER,
stsnXCProtPortNum INTEGER,
stsnXCProtNum INTEGER,
stsnXCRowStatus RowStatus }
stsnXCStsnTypeIdx OBJECT-TYPE
SYNTAX StsnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific STS-N rate of the cross-connection."
::= { stsnXCEntry 1 }
stsnXCSrcShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the STS-N facility that serves as
the source end-point for the cross connection."
::= { stsnXCEntry 2 }
stsnXCSrcSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the STS-N facility that serves as
the source end-point for the cross connection."
::= { stsnXCEntry 3 }
stsnXCSrcPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the STS-N facility that serves as
the source end-point for the cross connection."
::= { stsnXCEntry 4 }
stsnXCSrcIdx OBJECT-TYPE
SYNTAX INTEGER (1..192)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the STS-N within the identified port that serves
as the source end-point for the cross connection."
::= { stsnXCEntry 5 }
stsnXCDestShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the STS-N facility that serves as
the destination end-point for the cross connection."
::= { stsnXCEntry 6 }
stsnXCDestSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the STS-N entity that serves as the
destination end-point for the cross connection."
::= { stsnXCEntry 7 }
stsnXCDestPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the STS-N entity that serves as the
destination end-point for the cross connection."
::= { stsnXCEntry 8 }
stsnXCDestIdx OBJECT-TYPE
SYNTAX INTEGER (1..192)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the STS-N within the identified port that serves
as the destination end-point for the cross connection."
::= { stsnXCEntry 9 }
stsnXCType OBJECT-TYPE
SYNTAX XCType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of cross connection between the identified source and
destination STS-N facilities. This is a mandatory object when
a row of the STS-N cross connect table is created. Only 2-way
cross-connections are supported between STS-Ns."
::= { stsnXCEntry 10 }
stsnXCProtTypeNum OBJECT-TYPE
SYNTAX StsnType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The rate of the STS-N facility that serves as the protection
end-point for the cross connection."
::= { stsnXCEntry 11 }
stsnXCProtShelfNum OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the shelf of the STS-N entity that serves as the
protection end-point for the cross connection."
::= { stsnXCEntry 12 }
stsnXCProtSlotNum OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the slot of the STS-N entity that serves as the
protection end-point for the cross connection."
::= { stsnXCEntry 13 }
stsnXCProtPortNum OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the port of the STS-N entity that serves as the
protection end-point for the cross connection."
::= { stsnXCEntry 14 }
stsnXCProtNum OBJECT-TYPE
SYNTAX INTEGER (1..192)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the STS-N within the identified port that serves
as the protection end-point for the cross connection."
::= { stsnXCEntry 15 }
stsnXCRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
STS-N cross connection table, which in turn controls the
provisioning and de-provisioning of STS-N cross connections."
::= { stsnXCEntry 100 }
-----------------------------------------------------------------------
-- Objects related to cross connections of SDH VC-N facilities
-- on Muxponder circuit packs
-----------------------------------------------------------------------
vcnXCTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcnXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned cross
connection between SDH VC-N facilities on Muxponder circuit
packs."
::= { connections 4 }
vcnXCEntry OBJECT-TYPE
SYNTAX VcnXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the VC-N cross connection table."
INDEX { vcnXCVcnTypeIdx,
vcnXCSrcShelfIdx,
vcnXCSrcSlotIdx,
vcnXCSrcPortIdx,
vcnXCSrcIdx,
vcnXCDestShelfIdx,
vcnXCDestSlotIdx,
vcnXCDestPortIdx,
vcnXCDestIdx }
::= { vcnXCTable 1 }
VcnXCEntry ::= SEQUENCE { vcnXCVcnTypeIdx VcnType,
vcnXCSrcShelfIdx INTEGER,
vcnXCSrcSlotIdx INTEGER,
vcnXCSrcPortIdx INTEGER,
vcnXCSrcIdx INTEGER,
vcnXCDestShelfIdx INTEGER,
vcnXCDestSlotIdx INTEGER,
vcnXCDestPortIdx INTEGER,
vcnXCDestIdx INTEGER,
vcnXCType XCType,
vcnXCProtTypeNum VcnType,
vcnXCProtShelfNum INTEGER,
vcnXCProtSlotNum INTEGER,
vcnXCProtPortNum INTEGER,
vcnXCProtNum INTEGER,
vcnXCRowStatus RowStatus }
vcnXCVcnTypeIdx OBJECT-TYPE
SYNTAX VcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific rate of the VC-N cross-connection."
::= { vcnXCEntry 1 }
vcnXCSrcShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the VC-N facility that serves as
the source end-point for the cross connection."
::= { vcnXCEntry 2 }
vcnXCSrcSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the VC-N facility that serves as the
source end-point for the cross connection."
::= { vcnXCEntry 3 }
vcnXCSrcPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the VC-N facility that serves as the
source end-point for the cross connection."
::= { vcnXCEntry 4 }
vcnXCSrcIdx OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the VC-N within the identified port that serves
as the source end-point for the cross connection."
::= { vcnXCEntry 5 }
vcnXCDestShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the VC-N facility that serves as
the destination end-point for the cross connection."
::= { vcnXCEntry 6 }
vcnXCDestSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the VC-N entity that serves as the
destination end-point for the cross connection."
::= { vcnXCEntry 7 }
vcnXCDestPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the VC-N entity that serves as the
destination end-point for the cross connection."
::= { vcnXCEntry 8 }
vcnXCDestIdx OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the VC-N within the identified port that serves
as the destination end-point for the cross connection."
::= { vcnXCEntry 9 }
vcnXCType OBJECT-TYPE
SYNTAX XCType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of cross connection between the identified source and
destination VC-N facilities. This is a mandatory object when a
row of the VC-N cross connect table is created. Only 2-way
cross-connections are supported between VC-Ns."
::= { vcnXCEntry 10 }
vcnXCProtTypeNum OBJECT-TYPE
SYNTAX VcnType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The rate of the VC-N facility that serves as the protection
end-point for the cross connection."
::= { vcnXCEntry 11 }
vcnXCProtShelfNum OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the shelf of the VC-N entity that serves as the
protection end-point for the cross connection."
::= { vcnXCEntry 12 }
vcnXCProtSlotNum OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the slot of the VC-N entity that serves as the
protection end-point for the cross connection."
::= { vcnXCEntry 13 }
vcnXCProtPortNum OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the port of the VC-N entity that serves as the
protection end-point for the cross connection."
::= { vcnXCEntry 14 }
vcnXCProtNum OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the VC-N within the identified port that serves
as the protection end-point for the cross connection."
::= { vcnXCEntry 15 }
vcnXCRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
VC-N cross connection table, which in turn controls the
provisioning and de-provisioning of VC-N cross connections."
::= { vcnXCEntry 100 }
-----------------------------------------------------------------------
-- Objects related to cross connections of OTN ODU-N facilities
-- on Muxponder circuit packs
-----------------------------------------------------------------------
odunXCTable OBJECT-TYPE
SYNTAX SEQUENCE OF OdunXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned cross
connection between OTN ODU-N facilities on Muxponder circuit
packs."
::= { connections 5 }
odunXCEntry OBJECT-TYPE
SYNTAX OdunXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the ODU-N cross connection
table."
INDEX { odunXCOdunTypeIdx,
odunXCSrcShelfIdx,
odunXCSrcSlotIdx,
odunXCSrcPortIdx,
odunXCSrcIdx,
odunXCDestShelfIdx,
odunXCDestSlotIdx,
odunXCDestPortIdx,
odunXCDestIdx }
::= { odunXCTable 1 }
OdunXCEntry ::= SEQUENCE { odunXCOdunTypeIdx OdunType,
odunXCSrcShelfIdx INTEGER,
odunXCSrcSlotIdx INTEGER,
odunXCSrcPortIdx INTEGER,
odunXCSrcIdx INTEGER,
odunXCDestShelfIdx INTEGER,
odunXCDestSlotIdx INTEGER,
odunXCDestPortIdx INTEGER,
odunXCDestIdx INTEGER,
odunXCType XCType,
odunXCProtTypeNum OdunType,
odunXCProtShelfNum INTEGER,
odunXCProtSlotNum INTEGER,
odunXCProtPortNum INTEGER,
odunXCProtNum INTEGER,
odunXCRowStatus RowStatus }
odunXCOdunTypeIdx OBJECT-TYPE
SYNTAX OdunType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific rate of the ODU-N cross-connection."
::= { odunXCEntry 1 }
odunXCSrcShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the ODU-N facility that serves as
the source end-point for the cross connection."
::= { odunXCEntry 2 }
odunXCSrcSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the ODU-N facility that serves as
the source end-point for the cross connection."
::= { odunXCEntry 3 }
odunXCSrcPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the ODU-N facility that serves as
the source end-point for the cross connection."
::= { odunXCEntry 4 }
odunXCSrcIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the ODU-N within the identified port that serves
as the source end-point for the cross connection."
::= { odunXCEntry 5 }
odunXCDestShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the ODU-N facility that serves as
the destination end-point for the cross connection."
::= { odunXCEntry 6 }
odunXCDestSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the ODU-N entity that serves as the
destination end-point for the cross connection."
::= { odunXCEntry 7 }
odunXCDestPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the ODU-N entity that serves as the
destination end-point for the cross connection."
::= { odunXCEntry 8 }
odunXCDestIdx OBJECT-TYPE
SYNTAX INTEGER (1..1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the ODU-N within the identified port that serves
as the destination end-point for the cross connection."
::= { odunXCEntry 9 }
odunXCType OBJECT-TYPE
SYNTAX XCType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of cross connection between the identified source and
destination ODU-N facilities. This is a mandatory object when
a row of the ODU-N cross connect table is created. Only 2-way
cross-connections are supported between ODU-Ns."
::= { odunXCEntry 10 }
odunXCProtTypeNum OBJECT-TYPE
SYNTAX OdunType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The rate of the ODU-N facility that serves as the protection
end-point for the cross connection."
::= { odunXCEntry 11 }
odunXCProtShelfNum OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the shelf of the ODU-N entity that serves as the
protection end-point for the cross connection."
::= { odunXCEntry 12 }
odunXCProtSlotNum OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the slot of the ODU-N entity that serves as the
protection end-point for the cross connection."
::= { odunXCEntry 13 }
odunXCProtPortNum OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the port of the ODU-N entity that serves as the
protection end-point for the cross connection."
::= { odunXCEntry 14 }
odunXCProtNum OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of the ODU-N within the identified port that serves
as the protection end-point for the cross connection."
::= { odunXCEntry 15 }
odunXCRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
ODU-N cross connection table, which in turn controls the
provisioning and de-provisioning of ODU-N cross connections."
::= { odunXCEntry 100 }
-----------------------------------------------------------------------
-- Objects related to protection group pairings between optical
-- transceiver facilities on wavelength conversion circuit packs
--
-- A listing of provisioned protection group pairs is contained in
-- the xcvrProtGrpTable of the BTI 7000 Series MIB. When retrieved,
-- this table provides one row for each transceiver port protection
-- group pair provisioned on the BTI 7000 Series.
--
-- To create a protection group, a new row of the xcvrProtGrpTable must
-- be created. To delete a protection group, the corresponding row of
-- the table must be destroyed.
--
-- The following table lists the objects in each entry of the
-- xcvrProtGrpTable.
-----------------------------------------------------------------------
xcvrProtGrpTable OBJECT-TYPE
SYNTAX SEQUENCE OF XcvrProtGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned protection
group pairing between optical transceiver facilities on the
wavelength translator, regenerator and manager cards."
::= { protection 1 }
xcvrProtGrpEntry OBJECT-TYPE
SYNTAX XcvrProtGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical transceiver
protection group table."
INDEX { xcvrProtGrpWorkTypeIdx,
xcvrProtGrpWorkShelfIdx,
xcvrProtGrpWorkSlotIdx,
xcvrProtGrpWorkIdx,
xcvrProtGrpProtTypeIdx,
xcvrProtGrpProtShelfIdx,
xcvrProtGrpProtSlotIdx,
xcvrProtGrpProtIdx }
::= { xcvrProtGrpTable 1 }
XcvrProtGrpEntry ::= SEQUENCE { xcvrProtGrpWorkTypeIdx XcvrType,
xcvrProtGrpWorkShelfIdx INTEGER,
xcvrProtGrpWorkSlotIdx INTEGER,
xcvrProtGrpWorkIdx INTEGER,
xcvrProtGrpProtTypeIdx XcvrType,
xcvrProtGrpProtShelfIdx INTEGER,
xcvrProtGrpProtSlotIdx INTEGER,
xcvrProtGrpProtIdx INTEGER,
xcvrProtGrpId DisplayString,
xcvrProtGrpRowStatus RowStatus }
xcvrProtGrpWorkTypeIdx OBJECT-TYPE
SYNTAX XcvrType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of wavelength conversion function of the
transceiver port that serves as the working port for the
protection group."
::= { xcvrProtGrpEntry 1 }
xcvrProtGrpWorkShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the transceiver port that serves as
the working port for the protection group."
::= { xcvrProtGrpEntry 2 }
xcvrProtGrpWorkSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the transceiver port that serves as
the working port for the protection group."
::= { xcvrProtGrpEntry 3 }
xcvrProtGrpWorkIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the transceiver port that serves as
the working port for the protection group."
::= { xcvrProtGrpEntry 4 }
xcvrProtGrpProtTypeIdx OBJECT-TYPE
SYNTAX XcvrType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of wavelength conversion function of the
transceiver port that serves as the protection port for the
protection group."
::= { xcvrProtGrpEntry 5 }
xcvrProtGrpProtShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the transceiver port that serves as
the protection port for the protection group."
::= { xcvrProtGrpEntry 6 }
xcvrProtGrpProtSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the transceiver port that serves as
the protection port for the protection group."
::= { xcvrProtGrpEntry 7 }
xcvrProtGrpProtIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the transceiver port that serves as
the protection port for the protection group."
::= { xcvrProtGrpEntry 8 }
xcvrProtGrpId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
transceiver protection group in a manner useful to the user."
DEFVAL { "" }
::= { xcvrProtGrpEntry 9 }
xcvrProtGrpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
transceiver protection group table, which in turn controls
provisioning and deprovisioning of optical transceiver
protection groups."
::= { xcvrProtGrpEntry 100 }
-----------------------------------------------------------------------
-- Objects related to protection group pairings between SONET OC-N
-- facilities on Muxponder circuit packs
-----------------------------------------------------------------------
ocnProtGrpTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcnProtGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned protection
group pairing between SONET OC-N facilities on Muxponder
circuit packs."
::= { protection 2 }
ocnProtGrpEntry OBJECT-TYPE
SYNTAX OcnProtGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the OC-N facility protection
group table."
INDEX { ocnProtGrpWorkTypeIdx,
ocnProtGrpWorkShelfIdx,
ocnProtGrpWorkSlotIdx,
ocnProtGrpWorkPortIdx,
ocnProtGrpProtTypeIdx,
ocnProtGrpProtShelfIdx,
ocnProtGrpProtSlotIdx,
ocnProtGrpProtPortIdx }
::= { ocnProtGrpTable 1 }
OcnProtGrpEntry ::= SEQUENCE { ocnProtGrpWorkTypeIdx OcnType,
ocnProtGrpWorkShelfIdx INTEGER,
ocnProtGrpWorkSlotIdx INTEGER,
ocnProtGrpWorkPortIdx INTEGER,
ocnProtGrpProtTypeIdx OcnType,
ocnProtGrpProtShelfIdx INTEGER,
ocnProtGrpProtSlotIdx INTEGER,
ocnProtGrpProtPortIdx INTEGER,
ocnProtGrpId DisplayString,
ocnProtGrpRowStatus RowStatus }
ocnProtGrpWorkTypeIdx OBJECT-TYPE
SYNTAX OcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific rate of the OC-N facility that serves as the
working facility for the protection group. Currently, only
OCN-N facilities that are OTU-N mapped are supported for protection
grouping."
::= { ocnProtGrpEntry 1 }
ocnProtGrpWorkShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the OC-N facility that serves as
the working facility for the protection group."
::= { ocnProtGrpEntry 2 }
ocnProtGrpWorkSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the OC-N facility that serves as
the working facility for the protection group."
::= { ocnProtGrpEntry 3 }
ocnProtGrpWorkPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the OC-N facility that serves as
the working facility for the protection group."
::= { ocnProtGrpEntry 4 }
ocnProtGrpProtTypeIdx OBJECT-TYPE
SYNTAX OcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific rate of the OC-N facility that serves as the
protection facility for the protection group. Currently, only
OC-N facilities that are OTU-N mapped are supported for protection
grouping."
::= { ocnProtGrpEntry 5 }
ocnProtGrpProtShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the OC-N facility that serves as
the protection facility for the protection group."
::= { ocnProtGrpEntry 6 }
ocnProtGrpProtSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the OC-N facility that serves as
the protection facility for the protection group."
::= { ocnProtGrpEntry 7 }
ocnProtGrpProtPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the OC-N facility that serves as
the protection facility for the protection group."
::= { ocnProtGrpEntry 8 }
ocnProtGrpId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
OC-N protection group in a manner useful to the user."
DEFVAL { "" }
::= { ocnProtGrpEntry 9 }
ocnProtGrpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
OC-N protection group table, which in turn controls
provisioning and deprovisioning of OC-N facility
protection groups."
::= { ocnProtGrpEntry 100 }
-----------------------------------------------------------------------
-- Objects related to protection group pairings between SDH STM-N
-- facilities on Muxponder circuit packs
-----------------------------------------------------------------------
stmnProtGrpTable OBJECT-TYPE
SYNTAX SEQUENCE OF StmnProtGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned protection
group pairing between SDH STM-N facilities on Muxponder
circuit packs."
::= { protection 3 }
stmnProtGrpEntry OBJECT-TYPE
SYNTAX StmnProtGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the STM-N facility protection
group table."
INDEX { stmnProtGrpWorkTypeIdx,
stmnProtGrpWorkShelfIdx,
stmnProtGrpWorkSlotIdx,
stmnProtGrpWorkPortIdx,
stmnProtGrpProtTypeIdx,
stmnProtGrpProtShelfIdx,
stmnProtGrpProtSlotIdx,
stmnProtGrpProtPortIdx }
::= { stmnProtGrpTable 1 }
StmnProtGrpEntry ::= SEQUENCE { stmnProtGrpWorkTypeIdx StmnType,
stmnProtGrpWorkShelfIdx INTEGER,
stmnProtGrpWorkSlotIdx INTEGER,
stmnProtGrpWorkPortIdx INTEGER,
stmnProtGrpProtTypeIdx StmnType,
stmnProtGrpProtShelfIdx INTEGER,
stmnProtGrpProtSlotIdx INTEGER,
stmnProtGrpProtPortIdx INTEGER,
stmnProtGrpId DisplayString,
stmnProtGrpRowStatus RowStatus }
stmnProtGrpWorkTypeIdx OBJECT-TYPE
SYNTAX StmnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific rate of the STM-N facility that serves as the
working facility for the protection group. Currently, only
STM-N facilities that are OTU-N mapped are supported for protection
grouping."
::= { stmnProtGrpEntry 1 }
stmnProtGrpWorkShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the STM-N facility that serves as
the working facility for the protection group."
::= { stmnProtGrpEntry 2 }
stmnProtGrpWorkSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the STM-N facility that serves as
the working facility for the protection group."
::= { stmnProtGrpEntry 3 }
stmnProtGrpWorkPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the STM-N facility that serves as
the working facility for the protection group."
::= { stmnProtGrpEntry 4 }
stmnProtGrpProtTypeIdx OBJECT-TYPE
SYNTAX StmnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific rate of the STM-N facility that serves as the
protection facility for the protection group. Currently, only
STM-N facilities that are OTU-N mapped are supported for protection
grouping."
::= { stmnProtGrpEntry 5 }
stmnProtGrpProtShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the STM-N facility that serves as
the protection facility for the protection group."
::= { stmnProtGrpEntry 6 }
stmnProtGrpProtSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the STM-N facility that serves as
the protection facility for the protection group."
::= { stmnProtGrpEntry 7 }
stmnProtGrpProtPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the STM-N facility that serves as
the protection facility for the protection group."
::= { stmnProtGrpEntry 8 }
stmnProtGrpId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Textual data recorded by the user to describe the provisioned
STM-N protection group in a manner useful to the user."
DEFVAL { "" }
::= { stmnProtGrpEntry 9 }
stmnProtGrpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
STM-N protection group table, which in turn controls
provisioning and deprovisioning of STM-N facility
protection groups."
::= { stmnProtGrpEntry 100 }
-----------------------------------------------------------------------
-- Objects used to perform operations directed at the network element
-- as a whole
-----------------------------------------------------------------------
dbBackupAndRestore OBJECT IDENTIFIER ::= { neOperations 1 }
swUpgrade OBJECT IDENTIFIER ::= { neOperations 2 }
DbBackupAndRestoreCmd ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The MSCP maintains all provisionable data in non-volatile
storage so that configuration settings are retained during
system shutdowns and restarts. The configuration database
is version controlled to facilitate the detection of an
incompatible software load and/or database.
The BTI 7000 Series supports user-initiated backup and
restore operations of the configuration database through the
SNMP Set requests performed on the dbBackupAndRestoreCmd
object with a value corresponding to the required action.
In a backup operation, the database is uploaded to a
user-specified network location (that is, a local PC or a
remote PC) using the file transfer protocol (FTP), or it is
stored locally on the MSCP.
In a restore operation, the database is restored using a
version of the file from an FTP server or locally from the
MSCP. The integrity of the file is validated to ensure that
it matches the current software load on the BTI 7000 Series.
The DbBackupAndRestoreCmd textual convention is the value of
the dbBackupAndRestoreCmd object, which is used to activate a
database backup operation, or the various steps of a database
restore operation. These operations are initiated when a set
request is performed on the dbBackupAndRestoreCmd object with
a value corresponding to the desired action, as explained
below. A get request on this type returns the value noOp.
The valid values for DbBackupAndRestoreCmd that can be used in
a set operation are:
- 'invokeBackup': used to perform a database backup operation.
The operation may be used to perform a local database backup,
or to save the database backup to a remote repository.
- 'loadRestore': used to initiate a database restore
operation. The operation may be the restoration of a local
database backup or of a remote database backup
- 'invokeRestore': continues a database restore operation
after the loadRestore stage has completed. The database being
restored is made active on the SCP circuit pack at this stage.
- 'applyRestore': Obsolete this functionality is now done as
part of the invokeRestore.
- 'commitRestore': is used to complete a database restore
operation and can be used after the applyRestore action
completes
- 'cancelRestore': is used to cancel and back out of a
database restore operation in progress and can be used before
the commitRestore action is called.
In order for the set request on the dbBackupAndRestoreCmd
object to complete successfully, the values of other objects
must be set in the same set request for some of the commands.
The additional objects required to be set along with the
dbBackupAndRestoreCmd object for each DbBackupAndRestoreCmd
value are listed below.
- invokeBackup: must also set dbBackupAndRestoreType. If this
object is set to remote, then the dbBackupAndRestoreAddress,
dbBackupAndRestoreFtpUser and dbBackupAndRestorePswd object
values must also be specified in the set request. The
dbBackupAndRestoreCheckAlm object may optionally be set when
the invokeBackup action is performed. Also when the
dbBackupAndRestoreType is set to remote the
dbBackupAndRestorePath is optional. If not specified the
default name is used.
- loadRestore: must also set dbBackupAndRestoreType. If this
object is set to remote, then the dbBackupAndRestoreAddress,
dbBackupAndRestorePath, dbBackupAndRestoreFtpUser and
dbBackupAndRestorePswd object values must also be specified in
the set request. The dbBackupAndRestoreCheckSysName object may
be set when the loadRestore action is performed, but is not
mandatory.
- invokeRestore: must also set
dbBackupAndRestoreInvokeFilename to confirm the name of the
backed file to be used in the restore operation. Optionally,
the dbBackupAndRestoreCheckAlm object may be set.
- applyRestore, commitRestore, cancelRestore: no additional
object values are required to be included for these set
requests"
SYNTAX INTEGER { noOp (1),
invokeBackup (2),
loadRestore (3),
invokeRestore (4),
-- applyRestore (5), Obsolete as of release 7.3.0.
commitRestore (6),
cancelRestore (7) }
DbBackupAndRestoreType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Indicates the type of database backup operation to be
performed, or the type of database restore operation to be
performed. The meaning of the values are as follows.
- 'local': for a database backup, the backup is made on the NE
itself; for a database restore, the restoration is from a
local database backup file
- 'remote': for a database backup, the backup is made to an
external ftp server; for a database restore, the restoration
is from a database file located on an external ftp server
- 'remoteSftp': for a database backup, the backup is made to an
external sftp server; for a database restore, the restoration
is from a database file located on an external sftp server"
SYNTAX INTEGER { local (1),
remote (2),
remoteSftp (3) }
dbBackupAndRestoreCmd OBJECT-TYPE
SYNTAX DbBackupAndRestoreCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to activate the steps of a database backup
or database restore operation. The description of the
DbBackupAndRestoreCmd textual convention explains the usage of
this object to perform these operations."
::= { dbBackupAndRestore 1 }
dbBackupAndRestoreType OBJECT-TYPE
SYNTAX DbBackupAndRestoreType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to indicate whether a local database, or a
remote database is involved in the backup or restore operation
that is being activated with the dbBackupAndRestoreCmd object,
as explained in the DbBackupAndRestoreType textual
convention."
::= { dbBackupAndRestore 2 }
dbBackupAndRestoreAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP address of an ftp server which the NE database is
backed up to, or restored from. This object is used when the
dbBackupAndRestoreType is set to remote."
::= { dbBackupAndRestore 3 }
dbBackupAndRestorePath OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The directory path on the ftp server where where the NE
database backup is to be saved to, or restored from. This
object is used when the dbBackupAndRestoreType is set to
remote."
::= { dbBackupAndRestore 4 }
dbBackupAndRestoreFtpUser OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The user identifier to be used on the ftp server where the NE
database backup is to be saved to, or restored from. This
object is used when the dbBackupAndRestoreType is set to
remote."
::= { dbBackupAndRestore 5 }
dbBackupAndRestoreFtpPswd OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The password to be used on the ftp server where the NE
database backup is to be saved to, or restored from. This
object is used when the dbBackupAndRestoreType is set to
remote."
::= { dbBackupAndRestore 6 }
dbBackupAndRestoreCheckAlm OBJECT-TYPE
SYNTAX INTEGER { yes (1),
no (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to indicate whether or not the system is
to be checked for active alarms before proceding with a backup
or restore operation. If set to yes, the requested action will
not be performed if alarms are active on the system. If not
specified in the same set request as the dbBackupAndRestoreCmd
object, the value is defaulted to yes."
::= { dbBackupAndRestore 7 }
dbBackupAndRestoreCheckSysName OBJECT-TYPE
SYNTAX INTEGER { yes (1),
no (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to indicate whether or not the system name
of the NE targeted for a database restore operation against
the system name embedded in the database backup file to be
restored. If set to yes, the requested action will not be
performed if system names do not match. If not specified in
the same set request as the dbBackupAndRestoreCmd object, the
value is defaulted to yes."
::= { dbBackupAndRestore 8 }
dbBackupAndRestoreInvokeFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The name of the database backup file that is to be used in a
database restore operation. This object is set along with the
dbBackupAndRestoreCmd object when it is set to invokeRestore,
as a confirmation that the database that is to be restored is
the correct database. In order for the invokeRestore command
to proceed, the value set for this object must match the value
of the dbBackupAndRestoreFilename object."
::= { dbBackupAndRestore 9 }
dbBackupAndRestoreFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the database backup file that is present and ready
to be restored. The value of this field is valid after the
completion of the loadRestore command."
::= { dbBackupAndRestore 10 }
dbBackupAndRestoreResult OBJECT-TYPE
SYNTAX INTEGER { success (1),
failure (2) }
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates if the identified stage of the database backup and
restore process has resulted in success or failure."
::= { dbBackupAndRestore 11 }
SwUpgradeCmd ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "All BTI 7000 Series circuit packs are shipped with
pre-loaded software. At system commissioning, it is not
necessary to start the system by loading software.
However, during the life cycle of the BTI 7000 Series,
it might be necessary to upgrade the system software.
Normally, the system software is upgraded to:
<09> Support the functionality of new circuit packs
<09> Provide new features for existing circuit packs
<09> Add specific software improvements
Performing a system software upgrade on the BTI 7000 Series
is non-service affecting. The upgrade process is designed
for application environments that require that the optical
signals passing through the BTI 7000 Series are not interrupted.
The BTI 7000 Series supports a user-initiated software upgrade
operation through the SNMP Set requests performed on the
swUpgradeCmd object with a value corresponding to the required
action.
The SwUpgradeCmd textual convention is the value of the
swUpgradeCmd object, which is used to activate the various
steps of the software upgrade procedure on the system. These
steps are initiated when a set request is performed on the
swUpgradeCmd object with a value corresponding to the desired
action, as explained below. A get request will return the
value noOp.
The valid values for SwUpgradeCmd that can be used in a set
operation are:
- 'checkUpgrade': used to perform a pre-upgrade check of the
system to ensure that it is ready for the upgrade process, and
that the load files on the server are accessible.
- 'loadUpgrade': used to initiate a system upgrade by
downloading the load files from a remote server to the SCP
software load storage area.
- 'invokeUpgrade': continues a system upgrade operation after
the loadUpgrade stage has completed. First the upgrade load is
installed on all circuit packs in the system, then each card
is rebooted to run the upgrade load.
- 'commitUpgrade': is used to complete a system upgrade
operation and can be used after the invkUpgrade action
completes
- 'cancelUpgrade': is used to cancel and back out of a system
software upgrade operation in progress and can be used before
the cmmtUpgrade action is called.
- 'invokeScpUpgrade': is a special-purpose upgrade step used
in place of the invkUpgrade value when an upgrade is being
performed on an SCP pack only. Such a targeted upgrade is
valid only when an SCP pack is replaced and the new pack
requires a software upgrade to make its software version
consistent with the system
In order for the set request on the swUpgradeCmd object to
complete successfully, the values of other objects must be set
in the same set request for some of the commands. The
additional objects required to be set along with the
swUpgradeCmd object for each SwUpgradeCmd value are listed
below.
- checkUpgrade, loadUpgrade: must also set swUpgradeAddress,
swUpgradePath, swUpgradeFtpUser, swUpgradeFtpPswd and
swUpgradeFileTransferType object values to indicate where
the ftp or sftp server with the upgrade load files is to
be found, along with access parameters.
- invokeUpgrade, invokeScpUpgrade: must also set the
swUpgradeInvokeRelNum object to confirm the software version
that is to be used in the upgrade. The swUpgradeCheckAlm
object may be set, but is not mandatory.
- commitUpgrade, cancelUpgrade: no additional object values
are required to be specified for these set requests."
SYNTAX INTEGER { noOp (1),
checkUpgrade (2),
loadUpgrade (3),
invkUpgrade (4),
cmmtUpgrade (5),
cancUpgrade (6),
invkScpUpgrade (7) }
SwUpgradeFileTransferType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Indicates the protocol of the file transfer.
- 'ftp': an external ftp server is the source for the load
to be transfered.
- 'sftp': an external sftp server is the source for the load
to be transfered."
SYNTAX INTEGER { ftp (1),
sftp (2) }
swUpgradeCmd OBJECT-TYPE
SYNTAX SwUpgradeCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to activate the steps of a software
upgrade procedure on the system. The description of the
SwUpgradeCmd textual convention explains the usage of this
object to perform these operations."
::= { swUpgrade 1 }
swUpgradeAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP address of an ftp or sftp server from which the software
load files for the upgrade are to be downloaded."
::= { swUpgrade 2 }
swUpgradePath OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The directory path on the upgrade load files ftp or sftp server
where the software load files are found."
::= { swUpgrade 3 }
swUpgradeFtpUser OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The user identifier to be used on the ftp or sftp server from
which the upgrade load is downloaded."
::= { swUpgrade 4 }
swUpgradeFtpPswd OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The password to be used on the ftp or sftp server from which
the upgrade load is downloaded."
::= { swUpgrade 5 }
swUpgradeInvokeRelNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The release number of the software upgrade load that is
targeted in a software upgrade invoke operation. This object
must be set along with the swUpgradeCmd object when it is set
to invokeUpgrade or invokeScpUpgrade, as a confirmation that
the software load to be used in the upgrade is the correct
load."
::= { swUpgrade 6 }
swUpgradeCheckAlm OBJECT-TYPE
SYNTAX INTEGER { yes (1),
no (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to indicate whether or not the system is
to be checked for active alarms before proceding with a
software upgrade operation. If set to yes, the requested
action will not be performed if alarms are active on the
system. If not specified in the same set request as the
swUpgradeCmd object, the value is defaulted to yes."
::= { swUpgrade 7 }
swUpgradeActiveRelNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The release number of the software load that is installed on
the system and is currently active."
::= { swUpgrade 8 }
swUpgradeInactiveRelNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The release number of the software load that is installed on
the system and is currently inactive."
::= { swUpgrade 9 }
swUpgradeFileTransferType OBJECT-TYPE
SYNTAX SwUpgradeFileTransferType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to define the file transfer protocol used
to retreive the load from a remote server. The default value is
ftp"
::= { swUpgrade 10 }
-----------------------------------------------------------------------
-- Objects related to performing operations on provisioned circuit packs
--
-- When a circuit pack is restarted on the BTI 7000 Series, the following events
-- occur:
-- <20> Provisioning information is maintained.
-- <20> State information is re-synchronized at start up.
-- <20> Logs are maintained.
-- <20> Historical performance metric (PM) bins are cleared if the MSCP is restarted.
-- <20> Current PM bins are cleared if an amplifier or wavelength conversion circuit
-- pack is restarted.
-- <20> Clock time is kept up to date.
-- <20> Uptime is reset.
-- <20> Traffic is maintained if a warm restart is performed. A cold restart causes the
-- traffic path to be interrupted.
--
-- The cpRestartOpTable is used to perform circuit pack restarts. There is one row in
-- the table for every restartable circuit pack that is provisioned on the system. The
-- circuit pack restart is performed by setting the cpRestartOpCmd for the targeted
-- circuit pack row to perform either a warmRestart or a coldRestart.
--
-- The following table lists the objects in each entry of the cpRestartOpTable.
-----------------------------------------------------------------------
cpRestartOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpRestartOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned restartable
circuit pack on the NE to facilitate the performing of circuit
pack restarts."
::= { cpOperations 1 }
cpRestartOpEntry OBJECT-TYPE
SYNTAX CpRestartOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the circuit pack restart
operation table."
INDEX { cpRestartOpTypeIdx,
cpRestartOpShelfIdx,
cpRestartOpSlotIdx }
::= { cpRestartOpTable 1 }
CpRestartOpEntry ::= SEQUENCE { cpRestartOpTypeIdx CpType,
cpRestartOpShelfIdx INTEGER,
cpRestartOpSlotIdx INTEGER,
cpRestartOpCmd INTEGER }
cpRestartOpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of circuit pack targeted for the restart
operation."
::= { cpRestartOpEntry 1 }
cpRestartOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the circuit pack targeted for
the restart operation is provisioned."
::= { cpRestartOpEntry 2 }
cpRestartOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (0..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the circuit pack targeted for
the restart operation is provisioned. For ESI type circuit
packs, the slot will be 0. For CCM type circuit packs, the slot
can only be 1 or 2."
::= { cpRestartOpEntry 3 }
cpRestartOpCmd OBJECT-TYPE
SYNTAX INTEGER { noOp (1),
warmRestart (2),
coldRestart (3),
powerOn (4)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a circuit pack restart operation as follows.
- warmRestart causes a restart of the main processor only;
traffic is not affected
- coldRestart causes a full circuit pack restart, including
data path
- powerOn causes a circuit pack that has been powered down
due to a high temperature or voltage event to power on.
When this object is read, the value noOp is returned."
::= { cpRestartOpEntry 4 }
-----------------------------------------------------------------------
-- Objects related to performing operations on optical amplifier
-- facilities
--
-- The oaOOBRSDOpTable is used to perform an Override Optical Back Reflection
-- Shutdown operation on an optical amplifier. There is one entry in this table for
-- every provisioned amplifier on which such an operation can be performed. To
-- perform the operation, set the oaOOBRSOOpCmd object for the targeted amplifier
-- to overrideOBRSD.
--
-- The following table lists the objects in each entry of the oaOOBRSDOpTable.
-----------------------------------------------------------------------
oaOOBRSDOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaOOBRSDOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned optical
amplifier on the NE that supports the Override Optical Back
Reflection Shutdown operation."
::= { oaOperations 1 }
oaOOBRSDOpEntry OBJECT-TYPE
SYNTAX OaOOBRSDOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical amplifier override
optical back reflection shutdown operation table."
INDEX { oaOOBRSDOpTypeIdx,
oaOOBRSDOpShelfIdx,
oaOOBRSDOpSlotIdx,
oaOOBRSDOpIdx }
::= { oaOOBRSDOpTable 1 }
OaOOBRSDOpEntry ::= SEQUENCE { oaOOBRSDOpTypeIdx OaType,
oaOOBRSDOpShelfIdx INTEGER,
oaOOBRSDOpSlotIdx INTEGER,
oaOOBRSDOpIdx INTEGER,
oaOOBRSDOpCmd INTEGER,
oaOOBRSDOpTimer INTEGER }
oaOOBRSDOpTypeIdx OBJECT-TYPE
SYNTAX OaType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of optical amplifier."
::= { oaOOBRSDOpEntry 1 }
oaOOBRSDOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the optical amplifier
targeted for the operation is provisioned."
::= { oaOOBRSDOpEntry 2 }
oaOOBRSDOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the optical amplifier
facility targeted for the operation is provisioned."
::= { oaOOBRSDOpEntry 3 }
oaOOBRSDOpIdx OBJECT-TYPE
SYNTAX INTEGER (1..1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
optical amplifier facility has been provisioned."
::= { oaOOBRSDOpEntry 4 }
oaOOBRSDOpCmd OBJECT-TYPE
SYNTAX INTEGER { noOp (1),
overrideOBRSD (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a Override Optical Back Reflection Shutdown
operation when this object is set to overrideOBRSD. When read,
this object returns noOp."
::= { oaOOBRSDOpEntry 5 }
oaOOBRSDOpTimer OBJECT-TYPE
SYNTAX INTEGER (0..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to specify the time duration of an override back
reflection shutdown operation. It is only valid to set the
value of this object in the same set request as for the
oaOOBRSDOpCmd object. Despite the indicated value range, the
actual supported range is 20 to 600. The value 0 is returned
when this object is read, even if an overrideOBRSD operation
is in progress."
::= { oaOOBRSDOpEntry 6 }
-----------------------------------------------------------------------
-- Objects related to performing operations on optical transceiver
-- facilities
--
-- The xcvrLpbkOpTable is used to perform loopback operations on provisioned
-- transceiver port facilities on the wavelength conversion circuit packs. There is one
-- row in the table for each provisioned transceiver port on which a loopback
-- operation can be performed. To perform the loopback operation, set the
-- xcvrLpbkOpCmd object to oprLpbk. To release the loopback, set the
-- xcvrLpbkOpCmd object to rlsLpbk.
--
-- Note: The loopback operation can only be performed on a transceiver port if the
-- xcvrAdminStatus for the port is set to disabled.
--
-- The following table lists the objects in each entry of the xcvrLpbkOpTable.
-----------------------------------------------------------------------
xcvrLpbkOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF XcvrLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned optical
transceiver on the NE to facilitate the performing of
transceiver loopback operations."
::= { xcvrOperations 1 }
xcvrLpbkOpEntry OBJECT-TYPE
SYNTAX XcvrLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical transceiver loopback
operation table."
INDEX { xcvrLpbkOpTypeIdx,
xcvrLpbkOpShelfIdx,
xcvrLpbkOpSlotIdx,
xcvrLpbkOpIdx }
::= { xcvrLpbkOpTable 1 }
XcvrLpbkOpEntry ::= SEQUENCE { xcvrLpbkOpTypeIdx XcvrType,
xcvrLpbkOpShelfIdx INTEGER,
xcvrLpbkOpSlotIdx INTEGER,
xcvrLpbkOpIdx INTEGER,
xcvrLpbkOpCmd INTEGER }
xcvrLpbkOpTypeIdx OBJECT-TYPE
SYNTAX XcvrType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of wavelength conversion function of the
circuit pack of the transceiver port targeted for the loopback
operation."
::= { xcvrLpbkOpEntry 1 }
xcvrLpbkOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the transceiver targeted for the
loopback operation."
::= { xcvrLpbkOpEntry 2 }
xcvrLpbkOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the transceiver targeted for
the loopback operation is provisioned."
::= { xcvrLpbkOpEntry 3 }
xcvrLpbkOpIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
optical transceiver facility has been provisioned."
::= { xcvrLpbkOpEntry 4 }
xcvrLpbkOpCmd OBJECT-TYPE
SYNTAX INTEGER { noOp (1),
oprLpbk (2),
rlsLpbk (3),
oprTerminalLpbk (4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a loopback operation on a transceiver facility
as follows:
- oprLpbk: operates a loopback on the transceiver
- rlsLpbk: causes a previously invoked loopback to be released
- oprTermLpbk: operates a terminal loopback for the transceiver
When read, this object returns noOp."
::= { xcvrLpbkOpEntry 5 }
-----------------------------------------------------------------------
-- Objects related to performing protection switching operations on optical
-- transceiver facilities
--
-- The xcvrProtSwOpTable is used to perform protection switching operations on
-- transceiver port facilities. This table includes a row for every transceiver port
-- provisioned as part of a transceiver protection pair. The protection switch
-- operation is performed by setting the xcvrProtSwOpCmd object to the object value
-- that corresponds to the desired protection switching operation.
--
-- The following table lists the objects in each entry of the xcvrProtSwOpTable.
-----------------------------------------------------------------------
xcvrProtSwOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF XcvrProtSwOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned optical
transceiver on the NE configured to be part of a protection
group pair to facilitate the performing of transceiver
protection switching operations."
::= { xcvrOperations 2 }
xcvrProtSwOpEntry OBJECT-TYPE
SYNTAX XcvrProtSwOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the optical transceiver
protection switching operation table."
INDEX { xcvrProtSwOpTypeIdx,
xcvrProtSwOpShelfIdx,
xcvrProtSwOpSlotIdx,
xcvrProtSwOpIdx }
::= { xcvrProtSwOpTable 1 }
XcvrProtSwOpEntry ::= SEQUENCE { xcvrProtSwOpTypeIdx XcvrType,
xcvrProtSwOpShelfIdx INTEGER,
xcvrProtSwOpSlotIdx INTEGER,
xcvrProtSwOpIdx INTEGER,
xcvrProtSwOpCmd INTEGER }
xcvrProtSwOpTypeIdx OBJECT-TYPE
SYNTAX XcvrType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of wavelength conversion function of the
circuit pack of the transceiver port targeted for the
protection switching operation."
::= { xcvrProtSwOpEntry 1 }
xcvrProtSwOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the transceiver targeted for the
protection switching operation."
::= { xcvrProtSwOpEntry 2 }
xcvrProtSwOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the transceiver targeted
for the protection switching operation is provisioned."
::= { xcvrProtSwOpEntry 3 }
xcvrProtSwOpIdx OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
optical transceiver facility has been provisioned."
::= { xcvrProtSwOpEntry 4 }
xcvrProtSwOpCmd OBJECT-TYPE
SYNTAX ProtSwOpCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a protection switch on a transceiver facility
which is configured to be a part of a protection group, as
described in the ProtSwOpCmd textual convention."
::= { xcvrProtSwOpEntry 5 }
-----------------------------------------------------------------------
-- Objects related to performing loopback operations on SONET OC-N
-- facilities
--
-- The ocnLpbkOpTable is used to perform loopback operations on provisioned
-- SONET OC-N port facilities on muxponder circuit packs. There is one row in the
-- table for each provisioned SONET OC-N port on which a loopback operation can
-- be performed. To perform the loopback operation, set the ocnLpbkOpCmd object
-- to oprFacilityLpbk. To release the loopback, set the ocnLpbkOpCmd object to
-- rlsLpbk.
--
-- Note: The loopback operation can only be performed on an OC-N port if the
-- ocnAdminStatus for the port is set to disabled.
--
-- The following table lists the objects in each entry of the ocnLpbkOpTable.
-----------------------------------------------------------------------
ocnLpbkOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcnLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned OC-N
facility on the NE to facilitate the performing loopback
operations."
::= { ocnOperations 1 }
ocnLpbkOpEntry OBJECT-TYPE
SYNTAX OcnLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the OC-N loopback operation
table."
INDEX { ocnLpbkOpTypeIdx,
ocnLpbkOpShelfIdx,
ocnLpbkOpSlotIdx,
ocnLpbkOpPortIdx }
::= { ocnLpbkOpTable 1 }
OcnLpbkOpEntry ::= SEQUENCE { ocnLpbkOpTypeIdx OcnType,
ocnLpbkOpShelfIdx INTEGER,
ocnLpbkOpSlotIdx INTEGER,
ocnLpbkOpPortIdx INTEGER,
ocnLpbkOpCmd INTEGER }
ocnLpbkOpTypeIdx OBJECT-TYPE
SYNTAX OcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of OC-N signal which is targeted for the
loopback operation."
::= { ocnLpbkOpEntry 1 }
ocnLpbkOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the OC-N facility targeted for the
loopback operation."
::= { ocnLpbkOpEntry 2 }
ocnLpbkOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the OC-N facility targeted for
the loopback operation is provisioned."
::= { ocnLpbkOpEntry 3 }
ocnLpbkOpPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the OC-N
facility targeted for the loopback operation is provisioned."
::= { ocnLpbkOpEntry 4 }
ocnLpbkOpCmd OBJECT-TYPE
SYNTAX INTEGER { noOp (1),
oprFacilityLpbk (2),
rlsLpbk (3),
oprTerminalLpbk (4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a loopback operation on a OC-N facility as
follows:
- oprFacilityLpbk: operates an OC-N facility loopback
- oprTerminalLpbk: operates an OC-N terminal loopback
- rlsLpbk: releases a previously invoked loopback
Note that the terminal loopback can only be operated on a
client OC-N facility. When read, this object returns noOp."
::= { ocnLpbkOpEntry 5 }
ocnProtSwOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcnProtSwOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned SONET OC-N
facility on the NE configured to be part of a protection group
pair to facilitate the performing of OC-N line protection
switching operations."
::= { ocnOperations 2 }
ocnProtSwOpEntry OBJECT-TYPE
SYNTAX OcnProtSwOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the SONET OC-N facility
protection switching operation table."
INDEX { ocnProtSwOpTypeIdx,
ocnProtSwOpShelfIdx,
ocnProtSwOpSlotIdx,
ocnProtSwOpIdx }
::= { ocnProtSwOpTable 1 }
OcnProtSwOpEntry ::= SEQUENCE { ocnProtSwOpTypeIdx OcnType,
ocnProtSwOpShelfIdx INTEGER,
ocnProtSwOpSlotIdx INTEGER,
ocnProtSwOpIdx INTEGER,
ocnProtSwOpCmd INTEGER }
ocnProtSwOpTypeIdx OBJECT-TYPE
SYNTAX OcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific rate of OC-N facility targeted for the
protection switching operation."
::= { ocnProtSwOpEntry 1 }
ocnProtSwOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the OC-N facility targeted for
the protection switching operation."
::= { ocnProtSwOpEntry 2 }
ocnProtSwOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the OC-N facility
targeted for the protection switching operation is
provisioned."
::= { ocnProtSwOpEntry 3 }
ocnProtSwOpIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the OC-N
facility has been provisioned."
::= { ocnProtSwOpEntry 4 }
ocnProtSwOpCmd OBJECT-TYPE
SYNTAX ProtSwOpCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a protection switch on a OC-N facility which
is configured to be a part of a protection group, as described
in the ProtSwOpCmd textual convention."
::= { ocnProtSwOpEntry 5 }
-----------------------------------------------------------------------
-- Objects related to performing protection switching on SDH STS-N
-- facilities
--
-- The stsnProtSwOpTable is used to perform protection switching operations on
-- SONET STS-N path facilities. This table includes a row for every SONET STS-N
-- path facility provisioned as part of a SONET STS-N protection pair. The
-- protection switch operation is performed by setting the stsnProtSwOpCmd object
-- to the object value that corresponds to the desired protection switching operation.
--
-- The following table lists the objects in each entry of the stsnProtSwOpTable.
-----------------------------------------------------------------------
stsnProtSwOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF StsnProtSwOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every created SONET STS-N
facility on the system which is part of a protection group
pairing to facilitate the performing of STS-N protection
switching operations."
::= { stsnOperations 1 }
stsnProtSwOpEntry OBJECT-TYPE
SYNTAX StsnProtSwOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the SONET STS-N protection
switching operation table."
INDEX { stsnProtSwOpTypeIdx,
stsnProtSwOpShelfIdx,
stsnProtSwOpSlotIdx,
stsnProtSwOpPortIdx,
stsnProtSwOpIdx }
::= { stsnProtSwOpTable 1 }
StsnProtSwOpEntry ::= SEQUENCE { stsnProtSwOpTypeIdx StsnType,
stsnProtSwOpShelfIdx INTEGER,
stsnProtSwOpSlotIdx INTEGER,
stsnProtSwOpPortIdx INTEGER,
stsnProtSwOpIdx INTEGER,
stsnProtSwOpCmd INTEGER }
stsnProtSwOpTypeIdx OBJECT-TYPE
SYNTAX StsnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of STS-N signal targeted for the protection
switching operation."
::= { stsnProtSwOpEntry 1 }
stsnProtSwOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the STS-N facility targeted for the
protection switching operation."
::= { stsnProtSwOpEntry 2 }
stsnProtSwOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the STS-N facility targeted for the
protection switching operation."
::= { stsnProtSwOpEntry 3 }
stsnProtSwOpPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the STS-N facility targeted for the
protection switching operation."
::= { stsnProtSwOpEntry 4 }
stsnProtSwOpIdx OBJECT-TYPE
SYNTAX INTEGER (1..192)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The sts channel number of the STS-N facility targeted for the
protection switching operation."
::= { stsnProtSwOpEntry 5 }
stsnProtSwOpCmd OBJECT-TYPE
SYNTAX ProtSwOpCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a protection switch on a STS-N facility which
is part of a protection group pairing, as described in the
ProtSwOpCmd textual convention."
::= { stsnProtSwOpEntry 6 }
-----------------------------------------------------------------------
-- Objects related to performing loopback operations on SDH STM-N
-- facilities
--
-- The stmnLpbkOpTable is used to perform loopback operations on provisioned
-- SDH STM-N port facilities on muxponder circuit packs. There is one row in the
-- table for each provisioned SDH STM-N port on which a loopback operation can
-- be performed. To perform the loopback operation, set the stmnLpbkOpCmd object
-- to oprFacilityLpbk. To release the loopback, set the smtnLpbkOpCmd object to
-- rlsLpbk.
--
-- Note: The loopback operation can only be performed on a transceiver port if the
-- stmnAdminStatus for the port is set to disabled.
--
-- The following table lists the objects in each entry of the stmnLpbkOpTable.
-----------------------------------------------------------------------
stmnLpbkOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF StmnLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned STM-N
facility on the NE to facilitate the performing of STM-N
facility loopback operations."
::= { stmnOperations 1 }
stmnLpbkOpEntry OBJECT-TYPE
SYNTAX StmnLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the STM-N loopback operation
table."
INDEX { stmnLpbkOpTypeIdx,
stmnLpbkOpShelfIdx,
stmnLpbkOpSlotIdx,
stmnLpbkOpPortIdx }
::= { stmnLpbkOpTable 1 }
StmnLpbkOpEntry ::= SEQUENCE { stmnLpbkOpTypeIdx StmnType,
stmnLpbkOpShelfIdx INTEGER,
stmnLpbkOpSlotIdx INTEGER,
stmnLpbkOpPortIdx INTEGER,
stmnLpbkOpCmd INTEGER }
stmnLpbkOpTypeIdx OBJECT-TYPE
SYNTAX StmnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of STM-N signal which is targeted for the
loopback operation."
::= { stmnLpbkOpEntry 1 }
stmnLpbkOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the STM-N facility targeted for the
loopback operation."
::= { stmnLpbkOpEntry 2 }
stmnLpbkOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the STM-N facility targeted
for the loopback operation is provisioned."
::= { stmnLpbkOpEntry 3 }
stmnLpbkOpPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the STM-N
facility targeted for the loopback operation is provisioned."
::= { stmnLpbkOpEntry 4 }
stmnLpbkOpCmd OBJECT-TYPE
SYNTAX INTEGER { noOp (1),
oprFacilityLpbk (2),
rlsLpbk (3),
oprTerminalLpbk (4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a loopback operation on a STM-N facility as
follows:
- oprFacilityLpbk: operates an STM-N facility loopback
- oprTerminalLpbk: operates an STM-N terminal loopback
- rlsLpbk: releases a previously invoked loopback
Note that a terminal loopback can only be operated on a client
STM-N facility. When read, this object returns noOp."
::= { stmnLpbkOpEntry 5 }
stmnProtSwOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF StmnProtSwOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned SDH STM-N
facility on the NE configured to be part of a protection group
pair to facilitate the performing of STM-N line protection
switching operations."
::= { stmnOperations 2 }
stmnProtSwOpEntry OBJECT-TYPE
SYNTAX StmnProtSwOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the SDH STM-N facility
protection switching operation table."
INDEX { stmnProtSwOpTypeIdx,
stmnProtSwOpShelfIdx,
stmnProtSwOpSlotIdx,
stmnProtSwOpIdx }
::= { stmnProtSwOpTable 1 }
StmnProtSwOpEntry ::= SEQUENCE { stmnProtSwOpTypeIdx StmnType,
stmnProtSwOpShelfIdx INTEGER,
stmnProtSwOpSlotIdx INTEGER,
stmnProtSwOpIdx INTEGER,
stmnProtSwOpCmd INTEGER }
stmnProtSwOpTypeIdx OBJECT-TYPE
SYNTAX StmnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific rate of STM-N facility targeted for the
protection switching operation."
::= { stmnProtSwOpEntry 1 }
stmnProtSwOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the STM-N faacility targeted for
the protection switching operation."
::= { stmnProtSwOpEntry 2 }
stmnProtSwOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot within which the STM-N facility
targeted for the protection switching operation is
provisioned."
::= { stmnProtSwOpEntry 3 }
stmnProtSwOpIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the STM-N
facility has been provisioned."
::= { stmnProtSwOpEntry 4 }
stmnProtSwOpCmd OBJECT-TYPE
SYNTAX ProtSwOpCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a protection switch on a STM-N facility which
is configured to be a part of a protection group, as described
in the ProtSwOpCmd textual convention."
::= { stmnProtSwOpEntry 5 }
-----------------------------------------------------------------------
-- Objects related to performing protection switching operations on SDH VC-N
-- facilities
--
-- The vcnProtSwOpTable is used to perform protection switching operations on
-- SDH VC-N path facilities. This table includes a row for every SDH VC-N path
-- facility provisioned as part of a VC-N protection pair. The protection switch
-- operation is performed by setting the vcnProtSwOpCmd object to the object value
-- that corresponds to the desired protection switching operation.
--
-- The following table lists the objects in each entry of the vcnProtSwOpTable.
-----------------------------------------------------------------------
vcnProtSwOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcnProtSwOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every created SDH VC-N
facility on the system which is part of a protection group
pairing to facilitate the performing of VC-N protection
switching operations."
::= { vcnOperations 1 }
vcnProtSwOpEntry OBJECT-TYPE
SYNTAX VcnProtSwOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the SDH VC-N protection switching
operation table."
INDEX { vcnProtSwOpTypeIdx,
vcnProtSwOpShelfIdx,
vcnProtSwOpSlotIdx,
vcnProtSwOpPortIdx,
vcnProtSwOpIdx }
::= { vcnProtSwOpTable 1 }
VcnProtSwOpEntry ::= SEQUENCE { vcnProtSwOpTypeIdx VcnType,
vcnProtSwOpShelfIdx INTEGER,
vcnProtSwOpSlotIdx INTEGER,
vcnProtSwOpPortIdx INTEGER,
vcnProtSwOpIdx INTEGER,
vcnProtSwOpCmd INTEGER }
vcnProtSwOpTypeIdx OBJECT-TYPE
SYNTAX VcnType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of VC-N signal targeted for the protection
switching operation."
::= { vcnProtSwOpEntry 1 }
vcnProtSwOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the VC-N facility targeted for the
protection switching operation."
::= { vcnProtSwOpEntry 2 }
vcnProtSwOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot of the VC-N facility targeted for the
protection switching operation."
::= { vcnProtSwOpEntry 3 }
vcnProtSwOpPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port of the VC-N facility targeted for the
protection switching operation."
::= { vcnProtSwOpEntry 4 }
vcnProtSwOpIdx OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The index number of the VC-N facility targeted for the
protection switching operation."
::= { vcnProtSwOpEntry 5 }
vcnProtSwOpCmd OBJECT-TYPE
SYNTAX ProtSwOpCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a protection switch on a VC-N facility which
is part of a protection group pairing, as described in the
ProtSwOpCmd textual convention."
::= { vcnProtSwOpEntry 6 }
-----------------------------------------------------------------------
-- Objects related to performing operations on Gigabit Ethernet
-- facilities
--
-- The geLpbkOpTable is used to perform loopback operations on provisioned
-- Gigabit Ethernet port facilities on muxponder circuit packs. There is one row in
-- the table for each provisioned Gigabit Ethernet port on which a loopback operation
-- can be performed. To perform the loopback operation, set the geLpbkOpCmd
-- object to either oprFacilityLpbk or oprTerminalLpbk. To release the loopback, set
-- the smtnLpbkOpCmd object to rlsLpbk.
--
-- Note: The loopback operation can only be performed on a transceiver port if the
-- geAdminStatus for the port is set to disabled.
--
-- The following table lists the objects in each entry of the geLpbkOpTable.
-----------------------------------------------------------------------
geLpbkOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF GeLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned Gigabit
Ethernet facility on the NE to facilitate the performing of GE
facility loopback operations."
::= { geOperations 1 }
geLpbkOpEntry OBJECT-TYPE
SYNTAX GeLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the Gigabit Ethernet loopback
operation table."
INDEX { geLpbkOpShelfIdx,
geLpbkOpSlotIdx,
geLpbkOpPortIdx }
::= { geLpbkOpTable 1 }
GeLpbkOpEntry ::= SEQUENCE { geLpbkOpShelfIdx INTEGER,
geLpbkOpSlotIdx INTEGER,
geLpbkOpPortIdx INTEGER,
geLpbkOpCmd INTEGER }
geLpbkOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the Gigabit Ethernet facility
targeted for the loopback operation."
::= { geLpbkOpEntry 1 }
geLpbkOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the Gigabit Ethernet facility
targeted for the loopback operation is provisioned."
::= { geLpbkOpEntry 2 }
geLpbkOpPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
Gigabit Ethernet facility targeted for the loopback operation
is provisioned."
::= { geLpbkOpEntry 3 }
geLpbkOpCmd OBJECT-TYPE
SYNTAX INTEGER { noOp (1),
oprFacilityLpbk (2),
oprTerminalLpbk (3),
rlsLpbk (4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a loopback operation on a Gigabit Ethernet
facility as follows:
- oprFacilityLpbk: operates an GE facility loopback
- oprFacilityLpbk: operates an GE terminal loopback
- rlsLpbk: releases a previously invoked loopback
When read, this object returns noOp."
::= { geLpbkOpEntry 4 }
-----------------------------------------------------------------------
-- Objects related to performing operations on Fiber Channel
-- facilities
-----------------------------------------------------------------------
fcLpbkOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned Fiber
Channel facility on the NE to facilitate the performing of FC
facility loopback operations."
::= { fcOperations 1 }
fcLpbkOpEntry OBJECT-TYPE
SYNTAX FcLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the Fiber Channel loopback
operation table."
INDEX { fcLpbkOpShelfIdx,
fcLpbkOpSlotIdx,
fcLpbkOpPortIdx }
::= { fcLpbkOpTable 1 }
FcLpbkOpEntry ::= SEQUENCE { fcLpbkOpShelfIdx INTEGER,
fcLpbkOpSlotIdx INTEGER,
fcLpbkOpPortIdx INTEGER,
fcLpbkOpCmd INTEGER }
fcLpbkOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the Fiber Channel facility targeted
for the loopback operation."
::= { fcLpbkOpEntry 1 }
fcLpbkOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the Fiber Channel facility
targeted for the loopback operation is provisioned."
::= { fcLpbkOpEntry 2 }
fcLpbkOpPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the Fiber
Channel facility targeted for the loopback operation is
provisioned."
::= { fcLpbkOpEntry 3 }
fcLpbkOpCmd OBJECT-TYPE
SYNTAX INTEGER { noOp (1),
oprFacilityLpbk (2),
oprTerminalLpbk (3),
rlsLpbk (4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a loopback operation on a Fiber Channel
facility as follows:
- oprFacilityLpbk: operates an FC facility loopback
- oprFacilityLpbk: operates an FC terminal loopback
- rlsLpbk: releases a previously invoked loopback
When read, this object returns noOp."
::= { fcLpbkOpEntry 4 }
-----------------------------------------------------------------------
-- Objects related to performing operations on Bit Rate Independent
-- (BRI) facilities
-----------------------------------------------------------------------
briLpbkOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF BriLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned
Bit Rate Independent (BRI) facility on the NE to
facilitate the performing of BRI facility loopback
operations."
::= { briOperations 1 }
briLpbkOpEntry OBJECT-TYPE
SYNTAX BriLpbkOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the BRI loopback
operation table."
INDEX { briLpbkOpShelfIdx,
briLpbkOpSlotIdx,
briLpbkOpPortIdx }
::= { briLpbkOpTable 1 }
BriLpbkOpEntry ::= SEQUENCE { briLpbkOpShelfIdx INTEGER,
briLpbkOpSlotIdx INTEGER,
briLpbkOpPortIdx INTEGER,
briLpbkOpCmd INTEGER }
briLpbkOpShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf of the BRI facility targeted
for the loopback operation."
::= { briLpbkOpEntry 1 }
briLpbkOpSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1|3|5|7|9|11|13|15|17|19)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the BRI facility
targeted for the loopback operation is provisioned."
::= { briLpbkOpEntry 2 }
briLpbkOpPortIdx OBJECT-TYPE
SYNTAX INTEGER (3..12)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
BRI facility targeted for the loopback operation is
provisioned."
::= { briLpbkOpEntry 3 }
briLpbkOpCmd OBJECT-TYPE
SYNTAX INTEGER { noOp (1),
oprFacilityLpbk (2),
oprTerminalLpbk (3),
rlsLpbk (4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to perform a loopback operation on a BRI
facility as follows:
- oprFacilityLpbk: operates a BRI facility loopback
- oprFacilityLpbk: operates a BRI terminal loopback
- rlsLpbk: releases a previously invoked loopback
When read, this object returns noOp."
::= { briLpbkOpEntry 4 }
-----------------------------------------------------------------------
-- Objects used to control management operations related to data
-- communications
-----------------------------------------------------------------------
DataCommsPingCmd ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The DataCommsPingCmd textual convention is the value of the
dataCommsPingCmd object which is used to perform a ping
operation over the NE's OSC. The operation is initiated when a
set request is performed on the dataCommsPingCmd object with a
value corresponding to the ping action, as explained below.
The valid values for DataCommsPingCmd that can be used in a
set operation are:
- 'ping', used to trigger the ping operation over the OSC
A value of 'pingInProgress' is returned when the
dataCommsPingCmd object is read in a get operation if the ping
command entered has not yet completed, otherwise 'noOp' is
returned.
In order for the set request on a DataCommsPingCmd object to
complete successfully, the dataCommsPingCmd object, along with
the dataCommdPingAddress and optionally the
dataCommsPingNumAttemps objects must be set in the same set
request for a given row of the table. The purpose of these
objects is:
- dataCommsPingAddress: indicates the IP Address which is the
target of the ping operation
- dataCommsPingNumAttempts: indicates how many ping attempts
are to be made in the ping operation
Once the dataCommsPingCmd operation is completed by way of the
set operation on the dataCommsPingCmd and associated objects,
the result of the operation is checked by performing a get
operation on the dataCommsPingNumSuccesses object. When the
ping operation completes, the value of this object will be set
to the number of the attempted ping trials that resulted in a
successful ping."
SYNTAX INTEGER { noOp (1),
ping (2),
pingInProgress (3) }
-----------------------------------------------------------------------
-- Objects used to perform ping operations
--
-- The dataCommsPingTable is used to perform ping operations from the MSCP
-- circuit pack over the Optical Supervisory Channel (OSC) or a network
-- management interface of the BTI 7000 Series. This table includes a row for every
-- provisioned circuit pack on the BTI 7000 Series from which an IP ping request can
-- be sent.
--
-- The following table lists the objects in each entry of the dataCommsPingTable.
-----------------------------------------------------------------------
dataCommsPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF DataCommsPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned circuit pack
on the NE from which an IP ping request can be sent. This
includes all SCP and OSC type packs."
::= { dataCommsOperations 1 }
dataCommsPingEntry OBJECT-TYPE
SYNTAX DataCommsPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the data comms ping table."
INDEX { dataCommsPingCpTypeIdx,
dataCommsPingShelfIdx,
dataCommsPingSlotIdx }
::= { dataCommsPingTable 1 }
DataCommsPingEntry ::= SEQUENCE { dataCommsPingCpTypeIdx CpType,
dataCommsPingShelfIdx INTEGER,
dataCommsPingSlotIdx INTEGER,
dataCommsPingCmd INTEGER,
dataCommsPingAddress IpAddress,
dataCommsPingNumAttempts INTEGER,
dataCommsPingNumSuccesses INTEGER }
dataCommsPingCpTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object is used to indicate the type of circuit pack from
which the ping operation is to be conducted using the
dataCommsPingCmd object."
::= { dataCommsPingEntry 1 }
dataCommsPingShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object is used to indicate the shelf number containing
the circuit pack from which the ping operation is to be
conducted using the dataCommsPingCmd object."
::= { dataCommsPingEntry 2 }
dataCommsPingSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object is used to indicate the slot number containing the
circuit pack from which the ping operation is to be conducted
using the dataCommsPingCmd object."
::= { dataCommsPingEntry 3 }
dataCommsPingCmd OBJECT-TYPE
SYNTAX DataCommsPingCmd
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to trigger a ping operation from an OSC or
SCP circuit pack. The description of DataCommsPingCmd textual
convention explains the usage of this object to perform the
ping operation."
::= { dataCommsPingEntry 4 }
dataCommsPingAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to indicate the IP Address which is the
target of the ping operation to be conducted using the
dataCommsPingCmd object."
::= { dataCommsPingEntry 5 }
dataCommsPingNumAttempts OBJECT-TYPE
SYNTAX INTEGER ( 1..3 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to indicate how many ping attempts are to
be made in the ping operation to be conducted using the
dataCommsPingCmd object. The default is 3."
::= { dataCommsPingEntry 6 }
dataCommsPingNumSuccesses OBJECT-TYPE
SYNTAX INTEGER ( 0..3 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object is used to indicate how many ping trials attempted
in the ping operation resulted in a successful ping
completion."
::= { dataCommsPingEntry 7 }
-----------------------------------------------------------------------
-- Objects related to provisioning SONET Synchronization Attributes
-----------------------------------------------------------------------
cpSynchronizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpSynchronizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned circuit pack
that supports SONET synchronization configuration."
::= { synchronization 1 }
cpSynchronizationEntry OBJECT-TYPE
SYNTAX CpSynchronizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the circuit pack synchronization
table."
INDEX { cpSynchronizationTypeIdx,
cpSynchronizationShelfIdx,
cpSynchronizationSlotIdx }
::= { cpSynchronizationTable 1 }
CpSynchronizationEntry ::= SEQUENCE { cpSynchronizationTypeIdx CpType,
cpSynchronizationShelfIdx INTEGER,
cpSynchronizationSlotIdx INTEGER,
cpSynchronizationTimingMode INTEGER,
cpSynchronizationPrimRefSrcPortNum INTEGER,
cpSynchronizationPrimRefProtStatus ProtectionStatusType,
cpSynchronizationPrimProtStatQlfr OperStatQlfr,
cpSynchronizationSecRefSrcPortNum INTEGER,
cpSynchronizationSecRefProtStatus ProtectionStatusType,
cpSynchronizationSecProtStatQlfr OperStatQlfr,
cpSynchronizationPrimRefBasicSSM INTEGER,
cpSynchronizationSecRefBasicSSM INTEGER,
cpSynchronizationSwEvtType SyncSwEvtType
}
cpSynchronizationTypeIdx OBJECT-TYPE
SYNTAX CpType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific type of circuit pack provisioned."
::= { cpSynchronizationEntry 1 }
cpSynchronizationShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the shelf on which the circuit pack is
provisioned."
::= { cpSynchronizationEntry 2 }
cpSynchronizationSlotIdx OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the slot in which the circuit pack is
provisioned."
::= { cpSynchronizationEntry 3 }
cpSynchronizationTimingMode OBJECT-TYPE
SYNTAX INTEGER { internal (1),
line (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The timing mode used for SONET synchronization on the pack."
::= { cpSynchronizationEntry 4 }
cpSynchronizationPrimRefSrcPortNum OBJECT-TYPE
SYNTAX INTEGER (0..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The port number of the SONET facility that serves as the
primary timing reference source. When the value is 0, the
primary reference is not configured."
::= { cpSynchronizationEntry 5 }
cpSynchronizationPrimRefProtStatus OBJECT-TYPE
SYNTAX ProtectionStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The protection status of the primary timing reference source."
::= { cpSynchronizationEntry 6 }
cpSynchronizationPrimProtStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual list of qualifiers of the reported protection status
of the primary timing reference source."
::= { cpSynchronizationEntry 7 }
cpSynchronizationSecRefSrcPortNum OBJECT-TYPE
SYNTAX INTEGER (0..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The port number of the SONET facility that serves as the
secondary timing reference source. When the value is 0, the
secondary reference is not configured."
::= { cpSynchronizationEntry 8 }
cpSynchronizationSecRefProtStatus OBJECT-TYPE
SYNTAX ProtectionStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The protection status of the secondary timing reference
source."
::= { cpSynchronizationEntry 9 }
cpSynchronizationSecProtStatQlfr OBJECT-TYPE
SYNTAX OperStatQlfr
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual list of qualifiers of the reported protection status
of the secondary timing reference source."
::= { cpSynchronizationEntry 10 }
cpSynchronizationPrimRefBasicSSM OBJECT-TYPE
SYNTAX INTEGER { yes (1),
no (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable basic Synchronization Status Messaging (SSM)
functionality on the primary timing reference source."
DEFVAL { no }
::= { cpSynchronizationEntry 11 }
cpSynchronizationSecRefBasicSSM OBJECT-TYPE
SYNTAX INTEGER { yes (1),
no (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable basic Synchronization Status Messaging (SSM)
functionality on the primary timing reference source."
DEFVAL { no }
::= { cpSynchronizationEntry 12 }
cpSynchronizationSwEvtType OBJECT-TYPE
SYNTAX SyncSwEvtType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates the type of timing reference switching event that
has occurred on the circuit pack."
::= { cpSynchronizationEntry 13 }
-----------------------------------------------------------------------
-- Objects related to the network topology
--
-- The BTI 7000 Series supports network neighbor entries through the
-- networkNeighborTable.
--
-- The following table lists the objects relating to the
-- networkNeighborTable operation.
-----------------------------------------------------------------------
networkNeighborTable OBJECT-TYPE
SYNTAX SEQUENCE OF NetworkNeighborEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table is used to store information on the network
neighbors of the local network element. Each row contains
information on a specific network neighbor."
::= { topology 1 }
networkNeighborEntry OBJECT-TYPE
SYNTAX NetworkNeighborEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the network neighbor table."
INDEX { networkNeighborIdx }
::= { networkNeighborTable 1 }
NetworkNeighborEntry ::= SEQUENCE { networkNeighborIdx DisplayString,
networkNeighborIPAddr IpAddress,
networkNeighborRowStatus RowStatus }
networkNeighborIdx OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A textual identifier of the network neighbor."
::= { networkNeighborEntry 1 }
networkNeighborIPAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The primary IP Address of the network neighbor."
::= { networkNeighborEntry 2 }
networkNeighborRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
network neighbor table."
::= { networkNeighborEntry 3 }
-----------------------------------------------------------------------
-- OSPF objects
--
-----------------------------------------------------------------------
ospfGeneralTable OBJECT-TYPE
SYNTAX SEQUENCE OF OspfGeneralGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains all of general OSPF parameters
for the network element. The group can be created
and deleted but only one entry can exist in the table."
::= {topology 2}
ospfGeneralGroupEntry OBJECT-TYPE
SYNTAX OspfGeneralGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The list entry for the OSPF General Group parameters."
INDEX { ospfIdx }
::= {ospfGeneralTable 1}
OspfGeneralGroupEntry ::= SEQUENCE { ospfIdx INTEGER,
ospfRouterId IpAddress,
ospfAdminStat INTEGER,
ospfVersionNumber INTEGER,
ospfAreaBdrRtrStatus TruthValue,
ospfRouteRedist INTEGER,
ospfAreaId AreaID,
ospfRowStatus RowStatus }
ospfIdx OBJECT-TYPE
SYNTAX INTEGER (1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index used to identify the OSPF instance in order to
alow for creation and deletion to allow compatibility with
TL1 and CLI interfaces. Note the value is always 1."
DEFVAL { 1 }
::= { ospfGeneralGroupEntry 1 }
ospfRouterId OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A 32-bit integer uniquely identifying the router.
By convention, to ensure uniqueness, this
should default to the value of one of the
router's IP interface addresses.
This object is persistent."
::= { ospfGeneralGroupEntry 2 }
ospfAdminStat OBJECT-TYPE
SYNTAX INTEGER { enabled (1), disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of OSPF in the
router. The value 'enabled' denotes that the
OSPF Process is active on at least one interface;
'disabled' disables it on all interfaces.
This object is persistent."
DEFVAL { enabled }
::= { ospfGeneralGroupEntry 3 }
ospfVersionNumber OBJECT-TYPE
SYNTAX INTEGER { version2 (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current version number of the OSPF protocol is 2."
::= { ospfGeneralGroupEntry 4 }
ospfAreaBdrRtrStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A flag to note whether this router is an Area Border Router."
::= { ospfGeneralGroupEntry 5 }
ospfRouteRedist OBJECT-TYPE
SYNTAX INTEGER { none (1),
static (2),
connected (3),
staticAndConnected(4),
defOrig(5),
defOrigAndStatic(6),
defOrigAndConnected(7),
all(8) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates the extent of route redistribution.
Static - static routes,
Connected - routes connected to the node.
DefOrig - default routes from adjacent nodes."
DEFVAL { none }
::= { ospfGeneralGroupEntry 6 }
ospfAreaId OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The area ID associated with this OSPF item.
Note that although the area ID has the format of an
IP Address it is not actually an IP address."
::= { ospfGeneralGroupEntry 7 }
ospfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of the
ospf General Group parameters."
::= { ospfGeneralGroupEntry 8 }
-----------------------------------------------------------------------
-- OSPF Interface Table
-----------------------------------------------------------------------
ospfIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OspfIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The OSPF Interface Table describes the interfaces
from the viewpoint of OSPF."
::= { topology 3 }
ospfIfEntry OBJECT-TYPE
SYNTAX OspfIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The OSPF interface entry describes one interface
from the viewpoint of OSPF.
Information in this table is persistent and when this object
is written the entity is saved to non-volatile
storage."
INDEX { ospfIfSwitchId,
ospfIfShelfIdx,
ospfIfSlotIdx,
ospfIfType,
ospfIfIdx,
ospfIfSubIdx }
::= { ospfIfTable 1 }
OspfIfEntry ::= SEQUENCE { ospfIfSwitchId INTEGER,
ospfIfShelfIdx INTEGER,
ospfIfSlotIdx INTEGER,
ospfIfType PvxPortType,
ospfIfIdx INTEGER,
ospfIfSubIdx INTEGER,
ospfIfAreaId AreaID,
ospfIfAdminStat INTEGER,
ospfIfRtrPriority INTEGER,
ospfIfTransitDelay INTEGER,
ospfIfRetransInterval INTEGER,
ospfIfHelloInterval INTEGER,
ospfIfRtrDeadInterval INTEGER,
ospfIfMetricValue INTEGER,
ospfIfStatus RowStatus
}
ospfIfSwitchId OBJECT-TYPE
SYNTAX INTEGER (0..11)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the switch id on which the OSPF interface
exists. Set to zero if the switchId a switch Id is not
applicable for identification of the OSPF interface."
DEFVAL {0}
::= { ospfIfEntry 1 }
ospfIfShelfIdx OBJECT-TYPE
SYNTAX INTEGER (1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf on which the OSPF interface exists."
::= { ospfIfEntry 2 }
ospfIfSlotIdx OBJECT-TYPE
SYNTAX INTEGER (0..6)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the slot within the shelf corresponding to
the OSPF interface."
::= { ospfIfEntry 3 }
ospfIfType OBJECT-TYPE
SYNTAX PvxPortType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The type of the interface corresponding to the OSPF
interface. Set to zero if the ospfIfType is not applicable
for identification of the OSPF interface."
DEFVAL { unknown }
::= { ospfIfEntry 4 }
ospfIfIdx OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the interface within the slot corresponding
to the OSPF interface."
::= { ospfIfEntry 5 }
ospfIfSubIdx OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the sub-interface that the OSFP Interface
corresponds to. Set to zero if the ospfIfSubIdx is not
applicable for identification of the OSPF interface. "
DEFVAL {0}
::= { ospfIfEntry 6 }
ospfIfAreaId OBJECT-TYPE
SYNTAX AreaID
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A 32-bit integer uniquely identifying the area
to which the interface connects. Area ID
0.0.0.0 is used for the OSPF backbone."
::= { ospfIfEntry 7 }
ospfIfAdminStat OBJECT-TYPE
SYNTAX INTEGER { enabled (1), disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The OSPF interface's administrative status.
The value formed on the interface, and the interface
will be advertised as an internal route to some area.
The value 'disabled' denotes that the interface is
external to OSPF."
DEFVAL { enabled }
::= { ospfIfEntry 8 }
ospfIfRtrPriority OBJECT-TYPE
SYNTAX INTEGER (0..'FF'h)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The priority of this interface. Used in
multi-access networks, this field is used in
the designated router election algorithm. The
value 0 signifies that the router is not eligible
to become the designated router on this particular
network. In the event of a tie in this value,
routers will use their Router ID as a tie breaker."
DEFVAL { 1 }
::= { ospfIfEntry 9 }
ospfIfTransitDelay OBJECT-TYPE
SYNTAX INTEGER (0..3600)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The estimated number of seconds it takes to
transmit a link state update packet over this
interface. Note that the minimal value SHOULD be
1 second."
DEFVAL { 1 }
::= { ospfIfEntry 10 }
ospfIfRetransInterval OBJECT-TYPE
SYNTAX INTEGER (0..3600)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of seconds between link state advertisement
retransmissions, for adjacencies belonging to this
interface. This value is also used when retransmitting
database description and Link State request packets.
Note that minimal value SHOULD be 1 second."
DEFVAL { 5 }
::= { ospfIfEntry 11 }
ospfIfHelloInterval OBJECT-TYPE
SYNTAX INTEGER ( 1..'FFFF'h )
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The length of time, in seconds, between the Hello packets
that the router sends on the interface. This value must be
the same for all routers attached to a common network."
DEFVAL { 10 }
::= { ospfIfEntry 12 }
ospfIfRtrDeadInterval OBJECT-TYPE
SYNTAX INTEGER ( 0..'7FFFFFFF'h )
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The number of seconds that a router's Hello packets have
not been seen before its neighbors declare the router down.
This should be some multiple of the Hello interval. This
value must be the same for all routers attached to a common
network."
DEFVAL { 40 }
::= { ospfIfEntry 13 }
ospfIfMetricValue OBJECT-TYPE
SYNTAX INTEGER (0..'FFFF'h)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A metric used to identify the 'cost' associated with using
this interface."
DEFVAL { 10 }
::= { ospfIfEntry 14 }
ospfIfStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object permits management of the table by
facilitating actions such as row creation,
construction, and destruction.
The value of this object has no effect on
whether other objects in this conceptual row can be
modified."
::= { ospfIfEntry 15 }
-----------------------------------------------------------------------
-- OSPF LSDB Table
-----------------------------------------------------------------------
ospfLsdbTable OBJECT-TYPE
SYNTAX SEQUENCE OF OspfLsdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The OSPF Process's link state database (LSDB).
The LSDB contains the link state advertisements
from throughout the areas that the device is attached to."
::= { topology 4 }
ospfLsdbEntry OBJECT-TYPE
SYNTAX OspfLsdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A single link state advertisement."
INDEX { ospfLsdbAreaId, ospfLsdbType,
ospfLsdbLsid, ospfLsdbRouterId }
::= { ospfLsdbTable 1 }
OspfLsdbEntry ::= SEQUENCE { ospfLsdbAreaId AreaID,
ospfLsdbType INTEGER,
ospfLsdbLsid IpAddress,
ospfLsdbRouterId IpAddress,
ospfLsdbSequence Integer32,
ospfLsdbAge Integer32,
ospfLsdbChecksum Integer32
}
ospfLsdbAreaId OBJECT-TYPE
SYNTAX AreaID
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 32-bit identifier of the area from which
the LSA was received."
::= { ospfLsdbEntry 1 }
ospfLsdbType OBJECT-TYPE
SYNTAX INTEGER { routerLink (1),
networkLink (2),
summaryLink (3),
asSummaryLink (4),
asExternalLink (5), -- but see ospfAsLsdbTable
multicastLink (6),
nssaExternalLink (7),
areaOpaqueLink (10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of the link state advertisement.
Each link state type has a separate advertisement
format"
::= { ospfLsdbEntry 2 }
ospfLsdbLsid OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Link State ID is an LS Type Specific field
containing either a Router ID or an IP address;
it identifies the piece of the routing domain
that is being described by the advertisement."
::= { ospfLsdbEntry 3 }
ospfLsdbRouterId OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The 32-bit number that uniquely identifies the
originating router in the Autonomous System."
::= { ospfLsdbEntry 4 }
ospfLsdbSequence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The sequence number field is a signed 32-bit
integer. It starts with the value '80000001'h,
or -'7FFFFFFF'h, and increments until '7FFFFFFF'h.
Thus, a typical sequence number will be very negative.
It is used to detect old and duplicate Link State
Advertisements. The space of sequence numbers is linearly
ordered. The larger the sequence number, the more recent
the advertisement."
::= { ospfLsdbEntry 5 }
ospfLsdbAge OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This field is the age of the link state advertisement
in seconds."
::= { ospfLsdbEntry 6 }
ospfLsdbChecksum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This field is the checksum of the complete contents of
the advertisement, excepting the age field. The age field
is excepted so that an advertisement's age can be
incremented without updating the checksum. The checksum
used is the same that is used for ISO connectionless
datagrams; it is commonly referred to as the
Fletcher checksum."
::= { ospfLsdbEntry 7 }
-----------------------------------------------------------------------
-- OSPF Neighbor Table
-----------------------------------------------------------------------
ospfNbrTable OBJECT-TYPE
SYNTAX SEQUENCE OF OspfNbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table describing all non-virtual neighbors
in the locality of the OSPF router."
::= { topology 5 }
ospfNbrEntry OBJECT-TYPE
SYNTAX OspfNbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The information regarding a single neighbor.
Information in this table is persistent and when this object
is written the entity SHOULD save the change to non-volatile
storage."
INDEX { ospfNbrIpAddr, ospfNbrAddressLessIndex }
::= { ospfNbrTable 1 }
OspfNbrEntry ::= SEQUENCE { ospfNbrIpAddr IpAddress,
ospfNbrAddressLessIndex Integer32,
ospfNbrRtrId IpAddress,
ospfNbrOptions Integer32,
ospfNbrPriority DesignatedRouterPriority,
ospfNbrState INTEGER
}
ospfNbrIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "The IP address this neighbor is using in its
IP source address. Note that, on addressless
links, this will not be 0.0.0.0 but the
address of another of the neighbor's interfaces."
::= { ospfNbrEntry 1 }
ospfNbrAddressLessIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "On an interface having an IP address, zero.
On addressless interfaces, the corresponding
value of ifIndex in the Internet Standard MIB.
On row creation, this can be derived from the
instance."
::= { ospfNbrEntry 2 }
ospfNbrRtrId OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A 32-bit integer (represented as a type
IpAddress) uniquely identifying the neighboring
router in the Autonomous System."
::= { ospfNbrEntry 3 }
ospfNbrOptions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A bit mask corresponding to the neighbor's
options field.
Bit 0, if set, indicates that the system will
operate on Type of Service metrics other than
TOS 0. If zero, the neighbor will ignore all
metrics except the TOS 0 metric.
Bit 1, if set, indicates that the associated
area accepts and operates on external
information; if zero, it is a stub area.
Bit 2, if set, indicates that the system is
capable of routing IP multicast datagrams, that is
that it implements the multicast extensions to
OSPF.
Bit 3, if set, indicates that the associated
area is an NSSA. These areas are capable of
carrying type-7 external advertisements, which
are translated into type-5 external advertisements
at NSSA borders."
::= { ospfNbrEntry 4 }
ospfNbrPriority OBJECT-TYPE
SYNTAX DesignatedRouterPriority
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The priority of this neighbor in the designated
router election algorithm. The value 0 signifies
that the neighbor is not eligible to become
the designated router on this particular network."
::= { ospfNbrEntry 5 }
ospfNbrState OBJECT-TYPE
SYNTAX INTEGER { down (1),
attempt (2),
init (3),
twoWay (4),
exchangeStart (5),
exchange (6),
loading (7),
full (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The state of the relationship with this neighbor."
::= { ospfNbrEntry 6 }
-----------------------------------------------------------------------
-- Objects related to provisioned Ethernet facilities
------------------------------------------------------------------------
pvxL2IntfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PVXL2IntfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every provisioned Ethernet
facility on the system. Each row contains a list of attributes
that pertain to the facility."
::= { pvxBridge 3 }
pvxL2IntfEntry OBJECT-TYPE
SYNTAX PVXL2IntfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the ethIntfTable table."
INDEX { pvxL2IntfSwitchIdx,
pvxL2IntfShelfIdx,
pvxL2IntfSlotIdx,
pvxL2IntfPortTypeIdx,
pvxL2IntfPortIdx }
::= { pvxL2IntfTable 1 }
PVXL2IntfEntry ::= SEQUENCE { pvxL2IntfSwitchIdx INTEGER,
pvxL2IntfShelfIdx INTEGER,
pvxL2IntfSlotIdx INTEGER,
pvxL2IntfPortTypeIdx PvxPortType,
pvxL2IntfPortIdx INTEGER,
pvxL2IntfAdminStatus INTEGER,
pvxL2IntfOperStatus OperStatus,
pvxL2IntfType INTEGER,
pvxL2IntfSTpid INTEGER,
pvxL2IntfPvid INTEGER,
pvxL2IntfDefaultPriority INTEGER,
pvxL2IntfAllowedFrames INTEGER,
pvxL2IntfIngressFiltering TruthValue,
pvxL2IntfCtrlFrmProfileId Integer32,
pvxL2IntfMACAddr MacAddress,
pvxL2IntfRateLimit Integer32,
pvxL2IntfCoSProfileId Integer32,
pvxL2IntfIsUNI INTEGER,
pvxL2IntfSchedProfName DisplayString,
pvxL2IntfPriTCMapProfName DisplayString,
pvxL2IntfPCPCodingProfName DisplayString,
pvxL2IntfDscpPHBProfName DisplayString,
pvxL2IntfCtrlFrmProfileName DisplayString,
pvxL2IntfUseDei TruthValue,
pvxL2IntfIngressBandwidthProfile DisplayString,
pvxL2IntfEgressBandwidthProfile DisplayString,
pvxL2IntfTrustIncomingPCP TruthValue,
pvxL2IntfTrustIncomingDscp TruthValue,
pvxL2IntfBcastLimit INTEGER,
pvxL2IntfMcastLimit INTEGER,
pvxL2IntfDlfLimit INTEGER,
pvxL2IntfRowStatus RowStatus }
pvxL2IntfSwitchIdx OBJECT-TYPE
SYNTAX INTEGER(1..11)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the switch id of the provisioned ethernet
facility."
::= {pvxL2IntfEntry 1 }
pvxL2IntfShelfIdx OBJECT-TYPE
SYNTAX INTEGER (0|1|11|21|31)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the shelf id of the provisioned ethernet
facility."
::= {pvxL2IntfEntry 2 }
pvxL2IntfSlotIdx OBJECT-TYPE
SYNTAX INTEGER (0..20)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the instance id of the provisioned ethernet
facility."
::= {pvxL2IntfEntry 3 }
pvxL2IntfPortTypeIdx OBJECT-TYPE
SYNTAX PvxPortType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the instance id of the provisioned ethernet
facility."
::= {pvxL2IntfEntry 4 }
pvxL2IntfPortIdx OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The number of the port on the circuit pack on which the
ethernet facility is provisioned."
::= {pvxL2IntfEntry 5 }
pvxL2IntfAdminStatus OBJECT-TYPE
SYNTAX INTEGER { enabled (1),
disabled (2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of the Ethernet facility."
DEFVAL { enabled }
::= {pvxL2IntfEntry 6 }
pvxL2IntfOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The reported operational status of the Ethernet facility."
::= {pvxL2IntfEntry 7 }
pvxL2IntfType OBJECT-TYPE
SYNTAX INTEGER { pnp (1),
cep (2),
cnpPortbased (3),
cbp (4) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object is used to configure the type of a interface."
DEFVAL { pnp }
::= {pvxL2IntfEntry 8 }
pvxL2IntfSTpid OBJECT-TYPE
SYNTAX INTEGER { uni8100 (1),
nni88a8 (2),
nni9100 (3) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Ethernet type (TPID) of the S-TAG"
DEFVAL { uni8100 }
::= {pvxL2IntfEntry 9 }
pvxL2IntfPvid OBJECT-TYPE
SYNTAX INTEGER (1..4090)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The PVID (port-based VLAN ID) for the port"
::= {pvxL2IntfEntry 10 }
pvxL2IntfDefaultPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object sets the default priority of the interface."
::= {pvxL2IntfEntry 11 }
pvxL2IntfAllowedFrames OBJECT-TYPE
SYNTAX INTEGER { all (1),
vlanTagged (2),
priorityTagged (3) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "TODO: Does this feild need to support OR of the options?"
::= {pvxL2IntfEntry 12 }
pvxL2IntfIngressFiltering OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION "When this is true(1) the device will discard incoming frames
for VLANs which do not include this Port in its Member set.
When false(2), the port will accept all incoming frames.
This control does not affect VLAN independent BPDU frames,
such as GVRP and STP. It does affect VLAN dependent BPDU
frames, such as GMRP."
::= {pvxL2IntfEntry 13 }
pvxL2IntfCtrlFrmProfileId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION ""
::= {pvxL2IntfEntry 14 }
pvxL2IntfMACAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of the interface."
::= { pvxL2IntfEntry 15 }
pvxL2IntfRateLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This represents the interface rate limit in kilobits/s."
::= { pvxL2IntfEntry 16 }
pvxL2IntfCoSProfileId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This represents the Class of service profile for the
interface."
::= { pvxL2IntfEntry 17 }
pvxL2IntfIsUNI OBJECT-TYPE
SYNTAX INTEGER { neither (1),
uni (2),
nni (3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Switch port type. The default value set by the switch is neither."
::= {pvxL2IntfEntry 18 }
pvxL2IntfSchedProfName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The scheduler profile used by the interface."
::= {pvxL2IntfEntry 19 }
pvxL2IntfPriTCMapProfName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The priority to traffic class map profile used by the interface."
::= {pvxL2IntfEntry 20 }
pvxL2IntfPCPCodingProfName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The scheduler profile used by the interface."
::= {pvxL2IntfEntry 21 }
pvxL2IntfDscpPHBProfName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The internal priority setting for DSCP profile used by the interface."
::= {pvxL2IntfEntry 22 }
pvxL2IntfCtrlFrmProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The L2 control frame profile used by the interface."
::= {pvxL2IntfEntry 23 }
pvxL2IntfUseDei OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used by PNP port. By default, it is set to false by the switch."
::= {pvxL2IntfEntry 24 }
pvxL2IntfIngressBandwidthProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The ingress policy map profile used by the interface."
::= {pvxL2IntfEntry 25 }
pvxL2IntfEgressBandwidthProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The egress policy map profile used by the interface."
::= {pvxL2IntfEntry 26 }
pvxL2IntfTrustIncomingPCP OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used by all port type. By default, it is set to true by the switch."
::= {pvxL2IntfEntry 27 }
pvxL2IntfTrustIncomingDscp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used by all port type. By default, it is set to true by the switch."
::= {pvxL2IntfEntry 28 }
pvxL2IntfBcastLimit OBJECT-TYPE
SYNTAX INTEGER (20|40|60|100)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Broadcast rate limit as percentage of the line rate for
the port with default value of 100 (no storm control)."
DEFVAL { 100 }
::= { pvxL2IntfEntry 29 }
pvxL2IntfMcastLimit OBJECT-TYPE
SYNTAX INTEGER (20|40|60|100)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Multicast rate limit as percentage of the line rate for
the port with default value of 100 (no storm control)."
DEFVAL { 100 }
::= { pvxL2IntfEntry 30 }
pvxL2IntfDlfLimit OBJECT-TYPE
SYNTAX INTEGER (20|40|60|100)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Unicast DLF rate limit as percentage of the line rate for
the port with default value of 100 (no storm control)."
DEFVAL { 100 }
::= { pvxL2IntfEntry 31 }
pvxL2IntfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to control the addition and deletion of entries in the
PVX L2 Interface table."
::= {pvxL2IntfEntry 100 }
-----------------------------------------------------------------------
-- Objects used to retrieve error information for failed set requests.
-- These objects can optionally be included in set requests sent to
-- the agent. When the set request fails, the returned objects will
-- contain information to explain the reason for the set failure.
------------------------------------------------------------------------
setErrorInfo OBJECT IDENTIFIER ::= { miscellaneous 1 }
setErrorCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The BTI-specific error code for the set request failure."
::= { setErrorInfo 1 }
setErrorDesc OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A textual description string that explains the reason
for the failed set request."
::= { setErrorInfo 2 }
-----------------------------------------------------------------------
-- Event Notifications Objects
-----------------------------------------------------------------------
trapSeqNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A integer value indicating the place of the trap notification
message within the continual sequence of all notification
messages issued by the system."
::= { notificationObjects 1 }
evtDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The date and time at which an event notification was issued by
the system."
::= { evtNotificationObjects 1 }
tcaIntervalType OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The type of PM bin according to interval length during which a
performance monitoring threshold crossing occurred."
::= { evtNotificationObjects 2 }
tcaDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The date and time of the performance monitoring interval for
which a performance monitoring threshold crossing alert is
generated."
::= { evtNotificationObjects 3 }
tcaMontype OBJECT-TYPE
SYNTAX PMMontype
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Identify the performance monitoring monitored type for which a
threshold crossing alert is generated."
::= { evtNotificationObjects 4 }
tcaValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The measured value of the monitored type for which a
performance monitoring threshold crossing alert is generated."
::= { evtNotificationObjects 5 }
tcaThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The threshold for the monitored type that was exceeded
resulting in the generation of a performance monnitoring
threshold crossing alert."
::= { evtNotificationObjects 6 }
evtDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "A textual decription of the event."
::= { evtNotificationObjects 7 }
evtObjectType OBJECT-TYPE
SYNTAX NotifObjectType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Identifies the type of managed object against which the
event notification is raised."
::= { evtNotificationObjects 8 }
evtCodeType OBJECT-TYPE
SYNTAX NotifCodeType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This object value uniquely identifies the type of event
that has been generated."
::= { evtNotificationObjects 9 }
-----------------------------------------------------------------------
-- Database Change Event Notification Objects
-----------------------------------------------------------------------
dbChangeNotificationsObjects OBJECT IDENTIFIER ::= { dbChangeNotifications 1 }
dbChangeDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The date and time at which a database change notification was
issued by the system."
::= { dbChangeNotificationsObjects 1 }
dbChangeSeqNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "A integer value indicating the place of a database change
notification message within the continual sequence of all
database messages issued by the system."
::= { dbChangeNotificationsObjects 2 }
dbChangeOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "The OID of the object instance whose value has been changed in
the database."
::= { dbChangeNotificationsObjects 3 }
-----------------------------------------------------------------------
-- Condition Notification Control Objects
-----------------------------------------------------------------------
condNotifCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF CondNotifCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains one row for every condition notification
associated with a raise."
::= { condNotifCtrl 1 }
condNotifCtrlEntry OBJECT-TYPE
SYNTAX CondNotifCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the condition notification control
table."
INDEX { condNotifObjId }
::= { condNotifCtrlTable 1 }
CondNotifCtrlEntry ::= SEQUENCE { condNotifObjId OBJECT IDENTIFIER,
condNotifSeverity INTEGER,
condNotifDefaultSeverity INTEGER }
condNotifObjId OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The specific condition notification to set the severity for.
The value must correspond to the raise condition not the clear."
::= { condNotifCtrlEntry 1 }
condNotifSeverity OBJECT-TYPE
SYNTAX CondSeverity
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The severity associated with the condition notification.
- Only certain values are permitted for the set:
default, critial, major, minor, notAlarmed.
- Only certain values are visible for the get:
critial, major, minor, major-minor, notAlarmed"
::= { condNotifCtrlEntry 2 }
condNotifDefaultSeverity OBJECT-TYPE
SYNTAX CondSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The default severity associated with the condition notification.
Only certain of the CondSeverity values are visible:
critial, major, minor, major-minor, notAlarmed"
::= { condNotifCtrlEntry 3 }
-----------------------------------------------------------------------
-- The envCondAttrTable is used to manage environmental alarm
-- configuration.
------------------------------------------------------------------------
envCondAttrTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnvCondAttrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table is used to manage the configuration of
environmental alarm inputs. It contains one row for
each environmental condition input on the NE."
::= { condNotifCtrl 2 }
envCondAttrEntry OBJECT-TYPE
SYNTAX EnvCondAttrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The conceptual row object of the environmental condition
attribute table."
INDEX { envCondAttrHKIIdx }
::= { envCondAttrTable 1 }
EnvCondAttrEntry ::= SEQUENCE { envCondAttrHKIIdx INTEGER,
envCondAttrSeverity CondSeverity,
envCondAttrCodeType EnvNotifCodeType,
envCondAttrDescription DisplayString,
envCondAttrInputType INTEGER }
envCondAttrHKIIdx OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of the housekeeping input which drives the
activation of the environmental condition configured by this
entry of the table."
::= { envCondAttrEntry 1 }
envCondAttrSeverity OBJECT-TYPE
SYNTAX CondSeverity
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The severity reported for the configured environmental
condition when it is raised. The valid values are:
- minor
- major
- critical
- notAlarmed"
::= { envCondAttrEntry 2 }
envCondAttrCodeType OBJECT-TYPE
SYNTAX EnvNotifCodeType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The code for the specific environmental condition that
is reported when the housekeeping input indicates that
the condition is active."
::= { envCondAttrEntry 3 }
envCondAttrDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The textual decription of the environmental condition
that is reported when the condition is raised."
::= { envCondAttrEntry 4 }
envCondAttrInputType OBJECT-TYPE
SYNTAX INTEGER { normallyOpen (1),
normallyClosed (2),
disabled (3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies how the housekeeping input which drives the
reporting of the environmental condition is interpreted."
::= { envCondAttrEntry 5 }
-----------------------------------------------------------------------
-- Event Notification Control Objects
-----------------------------------------------------------------------
eventNotifState OBJECT-TYPE
SYNTAX INTEGER { eventsEnabled (1),
eventsDisabled (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows all events to be either disabled or enabled."
::= { eventNotifCtrl 1 }
-----------------------------------------------------------------------
-----------------------------------------------------------------------
-- Trap Definitions.
-----------------------------------------------------------------------
-----------------------------------------------------------------------
-----------------------------------------------------------------------
-- Event Notifications
--
-- The event trap types, as described in the BTI-7000-MIB, are against equipment
-- (such as, shelf, circuit pack and transceivers) and entities (such as, amplifiers and
-- Optical Supervisory Channel).
--
-- The trap notifications as defined in the BTI-7000-MIB include the following
-- information:
-- <20> Notification type (also known as Trap type in SNMPv1)<29> the name of the trap
-- as it appears in the BTI-7000-MIB
-- <20> Objects (also known as Variables in SNMPv1)<29> additional data values
-- embedded in the trap notification that carry data pertinent to the trap event
-- <20> Description - a general description of the meaning of the trap event
-- <20> Notification OID (also known as the combined Enterprise and Trap fields in
-- SNMPv1) - the notification object identifier is a string of numbers used to
-- identify objects, in this case traps, defined in the BTI-7000-MIB
-----------------------------------------------------------------------
shelfInvPluginEvt NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
shelfInvType,
shelfInvShortName,
shelfInvName,
shelfInvChassisPEC,
shelfInvChassisCLEI,
shelfInvRev,
shelfInvConfig,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A shelf has been detected through the shelf interconnect."
::= { shelfInvEvtNotifications 0 1 }
shelfInvUnpluginEvt NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A previously detected shelf is no longer detected through the
shelf interconnect."
::= { shelfInvEvtNotifications 0 2 }
slotInvPluginEvt NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
slotInvPackShortName,
slotInvPackName,
slotInvPackPEC,
slotInvPackCLEI,
slotInvPackSerialNum,
slotInvPackRev,
slotInvPackMfgDate,
slotInvPackMfgLoc,
slotInvPackTestDate,
slotInvPackTestLoc,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A circuit pack has been inserted into the identified slot."
::= { slotInvEvtNotifications 0 1 }
slotInvUnpluginEvt NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A circuit pack has been removed from the identified slot."
::= { slotInvEvtNotifications 0 2 }
slotInvUpgradeStageResultEvt NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
slotInvUpgradeStage,
slotInvUpgradeResult,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "The software upgrade process on the circuit pack in the
identified slot has completed a stage."
::= { slotInvEvtNotifications 0 3 }
pluggableInvPluginEvt NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
pluggableInvType,
pluggableInvPEC,
pluggableInvCLEI,
pluggableInvVendorName,
pluggableInvVendorOUI,
pluggableInvVendorPartNum,
pluggableInvVendorRev,
pluggableInvVendorSerialNum,
pluggableInvMfgDate,
pluggableInvConnectorType,
pluggableInvMinBitRate,
pluggableInvMaxBitRate,
pluggableInvNomBitRate,
pluggableInvEncoding,
pluggableInvWavelength,
pluggableInvReach,
pluggableInvTxFaultImpl,
pluggableInvLOSImpl,
pluggableInvDDiagImpl,
pluggableInvTxDisableImpl,
pluggableInvMedia,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A pluggable transceiver has been inserted into the identified
port."
::= { pluggableInvEvtNotifications 0 1 }
pluggableInvUnpluginEvt NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A pluggable transceiver has been removed from the identified
port."
::= { pluggableInvEvtNotifications 0 2 }
shelfStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { shelfIdx,
shelfOperStatus,
shelfOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the shelf's operational status or
operational status qualifier."
::= { shelfEvtNotifications 0 1 }
cpStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
cpOperStatus,
cpOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the circuit pack's operational
status or operational status qualifier."
::= { cpEvtNotifications 0 1 }
cpCheckUpgradeResultEvt NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
cpUpgradeResult,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Indicates the result of the check upgrade step of the
system-wide software upgrade process."
::= { cpEvtNotifications 0 2 }
cpUpgradeTransferResultEvt NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
cpUpgradeResult,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Indicates the result of the software download step of the
system-wide software upgrade process."
::= { cpEvtNotifications 0 3 }
cpUpgradeStageResultEvt NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
cpUpgradeStage,
cpUpgradeResult,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "The software upgrade process on the active circuit pack in the
identified slot has completed a stage."
::= { cpEvtNotifications 0 4 }
cpDbBackupResultEvt NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
dbBackupAndRestoreAddress,
dbBackupAndRestorePath,
dbBackupAndRestoreResult,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Indicates the result of an NE database backup operation."
::= { cpEvtNotifications 0 5 }
cpDbRestoreTransferResultEvt NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
dbBackupAndRestoreAddress,
dbBackupAndRestorePath,
dbBackupAndRestoreResult,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Indicates the result of the database download step of the NE
database restore process."
::= { cpEvtNotifications 0 6 }
cpDbInvokeResultEvt NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
dbBackupAndRestoreResult,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Indicates the result of the invoke step of the NE database
restore process."
::= { cpEvtNotifications 0 7 }
-- Obsolete as of release 7.3.0
cpDbApplyResultEvt NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
dbBackupAndRestoreResult,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS obsolete
DESCRIPTION "Indicates the result of the accept step of the NE database
restore process."
::= { cpEvtNotifications 0 8 }
oaStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaOperStatus,
oaOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the optical amplifier's
operational status or operational status qualifier."
::= { oaEvtNotifications 0 1 }
xcvrStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
xcvrOperStatus,
xcvrOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the transceiver's operational
status or operational status qualifier."
::= { xcvrEvtNotifications 0 1 }
xcvrProtSwitchEvt NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
xcvrProtSwEvtType,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A protection switch has occured on the optical transceiver
facility."
::= { xcvrEvtNotifications 0 2 }
xcvrTcaEvt NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
tcaIntervalType,
tcaDateAndTime,
tcaMontype,
tcaValue,
tcaThreshold,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This trap provides a threshold crossing alert for a
performance monitoring statistic on an optical transceiver
port."
::= { xcvrEvtNotifications 0 3 }
amdStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx,
amdOperStatus,
amdOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS obsolete
DESCRIPTION "Notification of a change in the operational status or
operational status qualifier of an active
multiplexer-demultiplexer port."
::= { amdEvtNotifications 0 1 }
oscStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { oscShelfIdx,
oscSlotIdx,
oscIdx,
oscOperStatus,
oscOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the optical supervisory channels's
operational status or operational status qualifier."
::= { dataCommsEvtNotifications 0 1 }
netMgmtStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { netMgmtIdx,
netMgmtOperStatus,
netMgmtOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the network management interface's
operational status or operational status qualifier."
::= { dataCommsEvtNotifications 0 2 }
ocnStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
ocnOperStatus,
ocnOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the operational status or
operational status qualifier of a SONET OC-N facility port."
::= { ocnEvtNotifications 0 1 }
ocnTcaEvt NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
tcaIntervalType,
tcaDateAndTime,
tcaMontype,
tcaValue,
tcaThreshold,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This trap provides a threshold crossing alert for a
performance monitoring statistic on a SONET OC-N facility."
::= { ocnEvtNotifications 0 2 }
ocnProtSwitchEvt NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
ocnProtSwEvtType,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A protection switch has occured on the identified OC-N
facility."
::= { ocnEvtNotifications 0 3 }
stsnProtSwitchEvt NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
stsnProtSwEvtType,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A protection switch has occured on the identified STS-N
channel."
::= { stsnEvtNotifications 0 2 }
stsnTcaEvt NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
tcaIntervalType,
tcaDateAndTime,
tcaMontype,
tcaValue,
tcaThreshold,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This trap provides a threshold crossing alert for a
performance monitoring statistic on a SONET STS-N facility."
::= { stsnEvtNotifications 0 3 }
stmnStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
stmnOperStatus,
stmnOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the operational status or
operational status qualifier of a SDH STM-N facility port."
::= { stmnEvtNotifications 0 1 }
stmnTcaEvt NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
tcaIntervalType,
tcaDateAndTime,
tcaMontype,
tcaValue,
tcaThreshold,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This trap provides a threshold crossing alert for a
performance monitoring statistic on a SDH STM-N facility."
::= { stmnEvtNotifications 0 2 }
stmnProtSwitchEvt NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
stmnProtSwEvtType,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A protection switch has occured on the identified STM-N
facility."
::= { stmnEvtNotifications 0 3 }
vcnProtSwitchEvt NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
vcnProtSwEvtType,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A protection switch has occured on the identified VC-N
channel."
::= { vcnEvtNotifications 0 2 }
vcnTcaEvt NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
tcaIntervalType,
tcaDateAndTime,
tcaMontype,
tcaValue,
tcaThreshold,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This trap provides a threshold crossing alert for a
performance monitoring statistic on a SDH VC-N facility."
::= { vcnEvtNotifications 0 3 }
geStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
geOperStatus,
geOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the operational status or
operational status qualifier of a Gigabit Ethernet facility
port."
::= { geEvtNotifications 0 1 }
geTcaEvt NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
tcaIntervalType,
tcaDateAndTime,
tcaMontype,
tcaValue,
tcaThreshold,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This trap provides a threshold crossing alert for a
performance monitoring statistic on a Gigabit Ethernet
facility."
::= { geEvtNotifications 0 2 }
fcStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
fcOperStatus,
fcOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the operational status or
operational status qualifier of a Fiber Channel facility
port."
::= { fcEvtNotifications 0 1 }
fcTcaEvt NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
tcaIntervalType,
tcaDateAndTime,
tcaMontype,
tcaValue,
tcaThreshold,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This trap provides a threshold crossing alert for a
performance monitoring statistic on a Fiber Channel facility."
::= { fcEvtNotifications 0 2 }
ethL1IFStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
ethIntfOperStatus,
ethIntfOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the operational status or
operational status qualifier of a L1 Ethernet facility
port."
::= { ethPortEvtNotifications 0 1 }
ethL1IFTcaEvt NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
tcaIntervalType,
tcaDateAndTime,
tcaMontype,
tcaValue,
tcaThreshold,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This trap provides a threshold crossing alert for a
performance monitoring statistic on an Ethernet Layer 1
interface facility."
::= { ethPortEvtNotifications 0 2 }
pvxL2IFTcaEvt NOTIFICATION-TYPE
OBJECTS { pvxL2IntfSwitchIdx,
pvxL2IntfShelfIdx,
pvxL2IntfSlotIdx,
pvxL2IntfPortTypeIdx,
pvxL2IntfPortIdx,
tcaIntervalType,
tcaDateAndTime,
tcaMontype,
tcaValue,
tcaThreshold,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This trap provides a threshold crossing alert for a
performance monitoring statistic on a PVX Pack Ethernet Layer 2
interface facility."
::= { pvxL2EvtNotifications 0 2 }
briStatusChangeEvt NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
briOperStatus,
briOperStatQlfr,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "Notification of a change in the operational status or
operational status qualifier of a BRI facility port."
::= { briEvtNotifications 0 1 }
cpSynchronizationSwitchEvt NOTIFICATION-TYPE
OBJECTS { cpSynchronizationTypeIdx,
cpSynchronizationShelfIdx,
cpSynchronizationSlotIdx,
cpSynchronizationSwEvtType,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "A synchronization timing reference switch has occurred
on the identified circuit pack."
::= { cpSynchronizationEvtNotifications 0 1 }
-----------------------------------------------------------------------
-- Condition Notifications
-----------------------------------------------------------------------
-- shelfInvMissingCond and shelfInvMissingClear traps have been
-- replaced by the shelfInvSysCommCond and shelfInvSysCommClear
-- notifications and, as such, have been marked as obsolete
shelfInvMissingCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "An expansion shelf is missing. To clear this condition, attach
an appropriate expansion shelf to the MSCP in the main shelf
of the system."
::= { shelfInvCondNotifications 0 1 }
shelfInvMissingClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "A previously active shelf missing condition has cleared."
::= { shelfInvCondNotifications 0 2 }
shelfInvUnknownCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A shelf is unknown to the system. This condition occurs
because the shelf is unknown to the system (for example, the
the FRU data cannot be read on the expansion shelf interface
(ESI) circuit pack in the expansion shelf). To clear this
condition, connect an appropriate shelf to its associated
MSCP."
::= { shelfInvCondNotifications 0 3 }
shelfInvUnknownClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting ,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active shelf unknown condition has cleared."
::= { shelfInvCondNotifications 0 4 }
-- The shelfInvExpansionShelfCommLOSCond, shelfInvExpansionShelfCommLinkDownCond,
-- and shelfInvExpansionShelfCommDeviceUnsupportedCond traps provide specific
-- shelf communications failure indications and, as such, the shelfInvCommCond
-- and shelfInvCommClear notifications are marked as obsolete
shelfInvCommCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "This condition indicates that a connected expansion shelf has
a communications failure between the multiport system control
processor (MSCP) and the expansion shelf interface (ESI)
circuit packs."
::= { shelfInvCondNotifications 0 5 }
shelfInvCommClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "A previously active shelf communications condition has
cleared."
::= { shelfInvCondNotifications 0 6 }
shelfInvPwrFeedAFailCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a power feed A failure. The system can continue to
function on power feed B. Plan to diagnose and correct the
problem as soon as possible."
::= { shelfInvCondNotifications 0 7 }
shelfInvPwrFeedAFailClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Power feed A condition has cleared."
::= { shelfInvCondNotifications 0 8 }
shelfInvPwrFeedBFailCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a power feed B failure. The system can continue to
function on power feed A. Plan to diagnose and correct the
problem as soon as possible."
::= { shelfInvCondNotifications 0 9 }
shelfInvPwrFeedBFailClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Power feed B condition has cleared."
::= { shelfInvCondNotifications 0 10 }
shelfInvPwrBrownoutCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a system power brownout. As voltage levels decrease,
the amplifiers fail, followed by the MSCP, and then the
cooling unit fails."
::= { shelfInvCondNotifications 0 11 }
shelfInvPwrBrownoutClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active power brownout condition on the shelf has
cleared."
::= { shelfInvCondNotifications 0 12 }
shelfInvSysCommCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "This condition indicates that backplane communication between
the multiport system control processor (MSCP) and the affected
circuit pack is interrupted. Normal OAM&P operations to the
circuit pack, like provisioning and performance monitoring,
are affected while this alarm is active."
::= { shelfInvCondNotifications 0 13 }
shelfInvSysCommClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "A previously active shelf missing condition has cleared."
::= { shelfInvCondNotifications 0 14 }
shelfInvExpansionShelfIdMismatchCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
shelfInvExpectedNEName,
shelfInvExpectedIPAddress,
shelfInvExpectedShelfNum,
shelfInvExpectedMSISerialNum,
shelfInvDiscoveredNEName,
shelfInvDiscoveredIPAddress,
shelfInvDiscoveredShelfNum,
shelfInvDiscoveredMSISerialNum,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the identifying information of the discovered
expansion shelf does not match that of the expected shelf."
::= { shelfInvCondNotifications 0 15 }
shelfInvExpansionShelfIdMismatchClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active expansion shelf identifier mismatch
condition has cleared."
::= { shelfInvCondNotifications 0 16 }
shelfInvExpansionShelfCommLOSCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that a connected expansion shelf has a
loss of signal between the multiport system control processor
(MSCP) and the expansion shelf interface (ESI) circuit packs.
The most likely causes are a fiber cut or a fault with the
Molex connector and cable assembly."
::= { shelfInvCondNotifications 0 17 }
shelfInvExpansionShelfCommLOSClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active expansion shelf communications LOS
condition has cleared."
::= { shelfInvCondNotifications 0 18 }
shelfInvExpansionShelfCommLinkDownCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that a connected expansion shelf has a
communications failure between the multiport system control
processor (MSCP) and the expansion shelf interface (ESI)
circuit packs."
::= { shelfInvCondNotifications 0 19 }
shelfInvExpansionShelfCommLinkDownClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active expansion shelf communications link down
condition has cleared."
::= { shelfInvCondNotifications 0 20 }
shelfInvExpansionShelfCommDeviceUnsupportedCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that an unknown device is connected to
the expansion shelf port of the multiport system control
processor (MSCP) on the main shelf."
::= { shelfInvCondNotifications 0 21 }
shelfInvExpansionShelfCommDeviceUnsupportedClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active expansion shelf communications device
unsupported condition has cleared."
::= { shelfInvCondNotifications 0 22 }
shelfInvTempMaxCond NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the temperature on the identified shelf has
risen above the maximum threshold."
::= { shelfInvCondNotifications 0 23 }
shelfInvTempMaxClear NOTIFICATION-TYPE
OBJECTS { shelfInvIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active shelf inventory maximum temperature
condition has cleared."
::= { shelfInvCondNotifications 0 24 }
slotInvMissingCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Circuit pack is missing. The alarm is triggered for one of
the following reasons: the provisioned circuit pack is missing
from its associated slot a filler circuit pack is missing from
an unprovisioned single-width or doublewidth slot a
single-width circuit pack is provisioned in a double-width
slot To clear this alarm, insert an appropriate single-width
or double-width circuit pack or filler circuit pack in the
associated single-width or double-width slot."
::= { slotInvCondNotifications 0 1 }
slotInvMissingClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack or replaceable unit missing
condition has cleared."
::= { slotInvCondNotifications 0 2 }
slotInvUnknownCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Circuit pack type is unknown to the system. This condition
occurs for the following two reasons: the circuit pack in the
associated slot is unknown to the system (for example, the
circuit pack is not supported by the software release running
on the system) two single-width circuit packs are in a
double-width slot To clear this condition, insert an
appropriate circuit pack in the associated slot."
::= { slotInvCondNotifications 0 3 }
slotInvUnknownClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack or replaceable unit unknown
condition has cleared."
::= { slotInvCondNotifications 0 4 }
slotInvCommCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that backplane communication between the
multiport system control processor (MSCP) and the circuit pack
is interrupted. Normal OAM&P operations to the circuit pack,
like provisioning and performance monitoring, are affected
while this alarm is active. If an amplifier or wavelength
conversion circuit pack has been provisioned already, it
continues to operate normally."
::= { slotInvCondNotifications 0 5 }
slotInvCommClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack communications condition has
cleared."
::= { slotInvCondNotifications 0 6 }
slotInvFailCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a circuit pack failure. The alarm is critical when a
circuit pack is provisioned and that it has fails in its
associated slot."
::= { slotInvCondNotifications 0 7 }
slotInvFailClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack fail condition has cleared."
::= { slotInvCondNotifications 0 8 }
slotInvUpgradeInProgressCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A software upgrade process has begun on the circuit pack in
the identified slot."
::= { slotInvCondNotifications 0 9 }
slotInvUpgradeInProgressClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is an auto upgrade in progress. This alarm is typically
seen when inserting a circuit pack other than a multiport
system control processor (MSCP)."
::= { slotInvCondNotifications 0 10 }
slotInvUpgradeFailureCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a circuit pack upgrade failure."
::= { slotInvCondNotifications 0 11 }
slotInvUpgradeFailureClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack software upgrade failure
condition has cleared."
::= { slotInvCondNotifications 0 12 }
slotInvVersionMismatchCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
slotInvSWVersion,
neSWVersion,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The circuit pack in the indicated slot is running a software
version which is inconsistent with the committed software
version of the system."
::= { slotInvCondNotifications 0 13 }
slotInvVersionMismatchClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack software version mismatch
condition has cleared."
::= { slotInvCondNotifications 0 14 }
slotInvCoolingUnitFailCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A cooling unit failure has occurred. One or more fans have
failed in the cooling unit."
::= { slotInvCondNotifications 0 15 }
slotInvCoolingUnitFailClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active shelf cooling unit failure condition has
cleared."
::= { slotInvCondNotifications 0 16 }
slotInvDspCommCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that communication has failed either
between the DSP and the processor handling backplane
communications on an optical amplifier circuit pack, or
between the variable optical equalizer (VOE) and the processor
handling backplane communications on an active mux/demux
circuit pack Normal OAM&P operations to the circuit pack, like
provisioning and performance monitoring, is affected when this
alarm is active."
::= { slotInvCondNotifications 0 17 }
slotInvDspCommClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active DSP control communications condition has
been cleared."
::= { slotInvCondNotifications 0 18 }
slotInvUnsupportedPackCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A replaceable unit inventory item is unsupported. In this
case, a multiport system control processor (MSCP) circuit pack
is plugged into any slot of the expansion shelf. However,
MSCPs are only supported in slot five of the main shelf."
::= { slotInvCondNotifications 0 19 }
slotInvUnsupportedPackClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active unsupported pack condition has cleared."
::= { slotInvCondNotifications 0 20 }
slotInvCoolingUnitMismatchCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The shelf is plugged in with a wring cooling unit."
::= { slotInvCondNotifications 0 21 }
slotInvCoolingUnitMismatchClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active cooling unit mismatch condition has cleared."
::= { slotInvCondNotifications 0 22 }
slotInvPwrFeedAFuseFailCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a circuit pack failure. The alarm is critical when a
circuit pack is provisioned and that it has fails in its
associated slot."
::= { slotInvCondNotifications 0 23 }
slotInvPwrFeedAFuseFailClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack fail condition has cleared."
::= { slotInvCondNotifications 0 24 }
slotInvPwrFeedBFuseFailCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a circuit pack failure. The alarm is critical when a
circuit pack is provisioned and that it has fails in its
associated slot."
::= { slotInvCondNotifications 0 25 }
slotInvPwrFeedBFuseFailClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack fail condition has cleared."
::= { slotInvCondNotifications 0 26 }
slotInvPowerFailCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a circuit pack failure. The alarm is critical when a
circuit pack is provisioned and that it has fails in its
associated slot."
::= { slotInvCondNotifications 0 27 }
slotInvPowerFailClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack fail condition has cleared."
::= { slotInvCondNotifications 0 28 }
slotInvHiTempAutoShutdownCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a circuit pack failure. The alarm is critical when a
circuit pack is provisioned and that it has fails in its
associated slot."
::= { slotInvCondNotifications 0 29 }
slotInvHiTempAutoShutdownClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack fail condition has cleared."
::= { slotInvCondNotifications 0 30 }
slotInvHTThreshExceededCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a circuit pack failure. The alarm is critical when a
circuit pack is provisioned and that it has fails in its
associated slot."
::= { slotInvCondNotifications 0 31 }
slotInvHTThreshExceededClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack fail condition has cleared."
::= { slotInvCondNotifications 0 32 }
slotInvHTSThreshExceededCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a circuit pack failure. The alarm is critical when a
circuit pack is provisioned and that it has fails in its
associated slot."
::= { slotInvCondNotifications 0 33 }
slotInvHTSThreshExceededClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack fail condition has cleared."
::= { slotInvCondNotifications 0 34 }
slotInvHTASUnsupportedCond NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a circuit pack failure. The alarm is critical when a
circuit pack is provisioned and that it has fails in its
associated slot."
::= { slotInvCondNotifications 0 35 }
slotInvHTASUnsupportedClear NOTIFICATION-TYPE
OBJECTS { slotInvShelfIdx,
slotInvSlotTypeIdx,
slotInvSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack fail condition has cleared."
::= { slotInvCondNotifications 0 36 }
shelfMismatchCond NOTIFICATION-TYPE
OBJECTS { shelfIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The type of the physically detected shelf does not match the
provisioned shelf type."
::= { shelfCondNotifications 0 1 }
shelfMismatchClear NOTIFICATION-TYPE
OBJECTS { shelfIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active shelf type mismatch condition has
cleared."
::= { shelfCondNotifications 0 2 }
shelfMissingCond NOTIFICATION-TYPE
OBJECTS { shelfIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An expansion shelf is missing. To clear this alarm, attach an
appropriate expansion shelf to the MSCP in the main shelf of
the system."
::= { shelfCondNotifications 0 3 }
shelfMissingClear NOTIFICATION-TYPE
OBJECTS { shelfIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active expansion shelf missing condition has
cleared."
::= { shelfCondNotifications 0 4 }
shelfConfigurationMismatchCond NOTIFICATION-TYPE
OBJECTS { shelfIdx,
shelfProvConfig,
shelfDiscConfig,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "The configuration type of the physically detected expansion
shelf does not match the provisioned expansion shelf
configuration type."
::= { shelfCondNotifications 0 5 }
shelfConfigurationMismatchClear NOTIFICATION-TYPE
OBJECTS { shelfIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS deprecated
DESCRIPTION "A previously active expansion shelf configuration mismatch
condition has cleared."
::= { shelfCondNotifications 0 6 }
cpMismatchCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a circuit pack mismatch. There is a mismatch between
the equipment provisioned for the slot and the physical
circuit pack that is inserted in the slot."
::= { cpCondNotifications 0 1 }
cpMismatchClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack type mismatch condition has
cleared."
::= { cpCondNotifications 0 2 }
cpConnectorMismatchCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A connector mismatch alarm occurs on a circuit pack that is
provisioned with a connector type that is different to the one
actually inserted."
::= { cpCondNotifications 0 3 }
cpConnectorMismatchClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical fiber connector type mismatch
condition has cleared."
::= { cpCondNotifications 0 4 }
cpInvalidProvCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The type of circuit pack that is provisioned in a slot that is
invalid for the shelf slot configuration."
::= { cpCondNotifications 0 5 }
cpInvalidProvClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active invalid circuit pack provisioning
condition has cleared."
::= { cpCondNotifications 0 6 }
cpSoftwareBankAFailCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a hardware failure in software bank A storage device.
During this alarm, software backups, upgrades and restores
cannot occur. When the MSCP is rebooting, the LEDs on the MSI
and the MSCP are lit."
::= { cpCondNotifications 0 7 }
cpSoftwareBankAFailClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active software Bank A failure condition has
cleared."
::= { cpCondNotifications 0 8 }
cpSoftwareBankBFailCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a hardware failure in software bank B storage device.
During this alarm, software backups, upgrades, and restores
cannot occur. When the MSCP is rebooting, the LEDs on the MSI
and the MSCP are lit."
::= { cpCondNotifications 0 9 }
cpSoftwareBankBFailClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active software Bank B failure condition has
cleared."
::= { cpCondNotifications 0 10 }
cpUpgradeInProgressCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that a system-wide software upgrade process is in
progress on the NE."
::= { cpCondNotifications 0 11 }
cpUpgradeInProgressClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active system-wide upgrade in progress condition
has cleared."
::= { cpCondNotifications 0 12 }
cpUpgradeFailCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the system-wide upgrade procedure has failed to
complete successfully."
::= { cpCondNotifications 0 15 }
cpUpgradeFailClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active circuit pack upgrade failure condition has
cleared."
::= { cpCondNotifications 0 16 }
cpDbRestoreInProgressCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a database restore in progress on the system."
::= { cpCondNotifications 0 17 }
cpDbRestoreInProgressClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active NE database restore condition has
cleared."
::= { cpCondNotifications 0 18 }
cpDbRecoveryFailCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a database recovery failure. If a new MSCP circuit
pack fails to acquire the database from the system, a database
recovery failure alarm can be triggered after replacing the
MSCP."
::= { cpCondNotifications 0 19 }
cpDbRecoveryFailClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active NE database recovery failure condition has
cleared."
::= { cpCondNotifications 0 20 }
cpFanFeedFailCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A cooling unit feed failure has occurred on a BTI 7030 shelf.
There are two cooling unit power feeds from the SCP to the
cooling unit. If one power feeds fails, a minor alarm is
raised. If both power feed fails, a major alarm is raised."
::= { cpCondNotifications 0 21 }
cpFanFeedFailClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active fan power feed failure condition has
cleared."
::= { cpCondNotifications 0 22 }
cpStorageCardFailCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the database storage card has failed."
::= { cpCondNotifications 0 23 }
cpStorageCardFailClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active database storage card failure condition
has cleared."
::= { cpCondNotifications 0 24 }
cpDbDeletionInProgressCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a database deletion in progress on the system."
::= { cpCondNotifications 0 25 }
cpDbDeletionInProgressClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active NE database deletion condition has
cleared."
::= { cpCondNotifications 0 26 }
cpDegradeCond NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that a failure or degradation has been detected
in one or more physical components on the identified
circuit pack, which may lead to a failure of the pack to
provide service normally."
::= { cpCondNotifications 0 27 }
cpDegradeClear NOTIFICATION-TYPE
OBJECTS { cpTypeIdx,
cpShelfIdx,
cpSlotIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Circuit Pack Degrade condition has
cleared."
::= { cpCondNotifications 0 28 }
oaCaseTempCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaCaseTemp,
oaCaseTempMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A case temperature high threshold is exceeded. A warning is
raised to indicate that the amplifier is nearing its shutdown
threshold. The circuit pack in the associated slot has
exceeded its case temperature high threshold. If the case
temperature continues to rise to its shutdown threshold, the
circuit pack automatically shuts down."
::= { oaCondNotifications 0 1 }
oaCaseTempClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier case temperature
condition has cleared."
::= { oaCondNotifications 0 2 }
oaCaseTempShutdownCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaCaseTemp,
oaCaseTempMaxShutdownTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A case temperature high threshold shutdown has occurred. The
optical amplifier is shutdown and taken out-of-service by the
system. The pump lasers are turned off and there is no
amplification."
::= { oaCondNotifications 0 3 }
oaCaseTempShutdownClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier case temperature
shutdown condition has cleared."
::= { oaCondNotifications 0 4 }
oaLaserMinTempShutdownCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaLaser1Temp,
oaLaser2Temp,
oaLaserTempMinShutdownTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A pump laser temperature low threshold shutdown has occurred.
The optical amplifier is shutdown and taken out-of-service by
the system."
::= { oaCondNotifications 0 5 }
oaLaserMinTempShutdownClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier minimum temperature
shutdown condition has cleared."
::= { oaCondNotifications 0 6 }
oaLaserMaxTempShutdownCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaLaser1Temp,
oaLaser2Temp,
oaLaserTempMaxShutdownTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A pump laser temperature high threshold shutdown has occurred.
The optical amplifier is shutdown and taken out-of-service by
the system."
::= { oaCondNotifications 0 7 }
oaLaserMaxTempShutdownClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier maximum temperature
shutdown condition has cleared."
::= { oaCondNotifications 0 8 }
oaOpticalPwrReceivedMinCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaOpticalPwrReceived,
oaOpticalPwrReceivedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The optical power received (OPR) low threshold is exceeded.
The input signal to an optical amplifier has reached the
optical power received low threshold. If the input signal
drops to below the input sensitivity level, the circuit pack
will degrade in performance."
::= { oaCondNotifications 0 9 }
oaOpticalPwrReceivedMinClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier minimum power received
condition has cleared."
::= { oaCondNotifications 0 10 }
oaOpticalPwrReceivedMaxCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaOpticalPwrReceived,
oaOpticalPwrReceivedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The optical power received (OPR) high threshold is crossed.
The input signal to an optical amplifier has reached the
optical power received high threshold."
::= { oaCondNotifications 0 11 }
oaOpticalPwrReceivedMaxClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier maximum power received
condition has cleared."
::= { oaCondNotifications 0 12 }
oaSSIOpticalPwrReceivedMaxCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaSSIOpticalPwrReceived,
oaSSIOpticalPwrReceivedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A second stage input optical power received (OPR) high
threshold crossing has occurred."
::= { oaCondNotifications 0 13 }
oaSSIOpticalPwrReceivedMaxClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier second stage input
maximum power received condition has cleared."
::= { oaCondNotifications 0 14 }
oaBackReflectionSafetyCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaBackReflectionSafetyTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Optical Back Reflection - High Threshold Safety Override
alarm indicates someone has activated the optical power
received optical back reflection high threshold safety
override (OPR-OBR-HTSO) command to override the automatic
power reduction (APR) feature of the amplifier lasers. This
command overrides the APR feature of the amplifier for 20 to
600 seconds. When the timer expires, the alarm clears."
::= { oaCondNotifications 0 17 }
oaBackReflectionSafetyClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier back reflection safety
condition has cleared."
::= { oaCondNotifications 0 18 }
oaOpticalPwrTransmittedMinCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaOpticalPwrTransmitted,
oaOpticalPwrTransmittedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The optical power transmitted (OPT) low threshold is crossed."
::= { oaCondNotifications 0 19 }
oaOpticalPwrTransmittedMinClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier minimum transmitted
power condition has cleared."
::= { oaCondNotifications 0 20 }
oaOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaOpticalPwrTransmitted,
oaOpticalPwrTransmittedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The optical power transmitted (OPT) high threshold has been
exceeded on the amplifier."
::= { oaCondNotifications 0 21 }
oaOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier maximum transmitted
power condition has cleared."
::= { oaCondNotifications 0 22 }
oaMSInsertionLossCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
oaMSInsertionLoss,
oaMSInsertionLossMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A mid-stage insertion loss high threshold is exceeded for a
mid-stage amplifier."
::= { oaCondNotifications 0 23 }
oaMSInsertionLossClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier midstage insertion loss
condition has cleared."
::= { oaCondNotifications 0 24 }
oaAmplifierConditioningCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is an amplifier conditioning problem. When an amplifier
is initially plugged in, thermo-electric coolers (TEC) work to
control the pump laser temperature to between 16 degrees and
34 degrees Celsius. Until the pump laser temperature is within
range, the amplifier conditioning problem is present. If the
amplifier conditioning problem persists for more than 30
minutes, the condition is cleared and either a laser
temperature low threshold or a laser temperature high
threshold alarm is raised."
::= { oaCondNotifications 0 25 }
oaAmplifierConditioningClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier conditioning condition
has cleared."
::= { oaCondNotifications 0 26 }
oaDspCommCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that communication has failed between the
DSP and the processor handling backplane communications on an
optical amplifier circuit pack. Normal OAM&P operations to the
circuit pack, like provisioning and performance monitoring, is
affected when this alarm is active."
::= { oaCondNotifications 0 27 }
oaDspCommClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical amplifier DSP communications
condition has cleared."
::= { oaCondNotifications 0 28 }
oaBackReflectionSafetyOverrideCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting ,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Optical Back Reflection - High Threshold Safety Override
alarm indicates someone has activated the high threshold
safety override command to override the automatic power
reduction (APR) feature of the amplifier lasers. This command
overrides the APR feature of the amplifier for 20 to 600
seconds. When the timer expires, the alarm clears."
::= { oaCondNotifications 0 41 }
oaBackReflectionSafetyOverrideClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active back reflection safety override condition
has been cleared."
::= { oaCondNotifications 0 42 }
oaBackReflectionHighThresholdCond NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting ,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Optical Amplifier Back Reflection High Threshold alarm
indicates that the measured optical back reflection power has
exceeded the high threshold. This serves as a warning that
optical back reflection is operating at an elevated level, and
that continued increases in the optical back reflection level
may result in an automatic laser safety shutdown."
::= { oaCondNotifications 0 43 }
oaBackReflectionHighThresholdClear NOTIFICATION-TYPE
OBJECTS { oaTypeIdx,
oaShelfIdx,
oaSlotIdx,
oaIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active back reflection high threshold condition
has been cleared."
::= { oaCondNotifications 0 44 }
oscLossOfSignalCond NOTIFICATION-TYPE
OBJECTS { oscShelfIdx,
oscSlotIdx,
oscIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This condition indicates that an SFP transceiver has
experienced an input power drop that is below the manufacturer
s preset threshold."
::= { dataCommsCondNotifications 0 1 }
oscLossOfSignalClear NOTIFICATION-TYPE
OBJECTS { oscShelfIdx,
oscSlotIdx,
oscIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical supervisory channel loss of signal
condition has cleared."
::= { dataCommsCondNotifications 0 2 }
oscSfpMissingCond NOTIFICATION-TYPE
OBJECTS { oscShelfIdx,
oscSlotIdx,
oscIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An SFP transceiver is missing from its associated port in an
MSCP circuit pack. To clear this alarm, insert an appropriate
transceiver in the associated port of the MSCP circuit pack."
::= { dataCommsCondNotifications 0 3 }
oscSfpMissingClear NOTIFICATION-TYPE
OBJECTS { oscShelfIdx,
oscSlotIdx,
oscIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active optical supervisory channel SFP missing
condition has cleared."
::= { dataCommsCondNotifications 0 4 }
pluggableInvUnknownCond NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The SFP or XFP transceiver type is unknown to the system. This
alarm occurs because the transceiver is not supported by the
current software. To clear this alarm, insert a readable SFP
or XFP transceiver in the associated port of the circuit
pack."
::= { pluggableInvCondNotifications 0 1 }
pluggableInvUnknownClear NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Pluggable Inventory Unknown condition has
cleared."
::= { pluggableInvCondNotifications 0 2 }
pluggableInvCommCond NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that communication between a circuit pack
and an inserted small form factor pluggable (SFP) transceiver
is not reliable."
::= { pluggableInvCondNotifications 0 3 }
pluggableInvCommClear NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Pluggable Inventory communications
condition has cleared."
::= { pluggableInvCondNotifications 0 4 }
pluggableInvFailCond NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is an SFP or XFP transceiver failure."
::= { pluggableInvCondNotifications 0 5 }
pluggableInvFailClear NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Pluggable Inventory fail condition has
cleared."
::= { pluggableInvCondNotifications 0 6 }
pluggableInvMismatchCond NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is an SFP mismatch condition active. There is a mismatch
between the SFP transceiver provisioned for a port of a
circuit pack and the physical SFP transceiver that is inserted
in the port."
::= { pluggableInvCondNotifications 0 7 }
pluggableInvMismatchClear NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Pluggable Inventory mismatch condition has
cleared."
::= { pluggableInvCondNotifications 0 8 }
pluggableInvMissingCond NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is an SFP or XFP missing from the indicated port."
::= { pluggableInvCondNotifications 0 9 }
pluggableInvMissingClear NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Pluggable Inventory missing condition has
cleared."
::= { pluggableInvCondNotifications 0 10 }
pluggableInvUnsupportedCond NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The electrical SFP transceiver type is NOT supported in the given
port. This alarm occurs when an electrical SFP is plugged into a
port that does not support GE. To clear this alarm, remove the
electrical SFP."
::= { pluggableInvCondNotifications 0 11 }
pluggableInvUnsupportedClear NOTIFICATION-TYPE
OBJECTS { pluggableInvShelfIdx,
pluggableInvSlotTypeIdx,
pluggableInvSlotIdx,
pluggableInvPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Pluggable unsupported condition has cleared."
::= { pluggableInvCondNotifications 0 12 }
xcvrMissingCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An SFP or XFP transceiver is missing from its associated port
in a circuit pack."
::= { xcvrCondNotifications 0 1 }
xcvrMissingClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active transceiver port missing condition has
cleared."
::= { xcvrCondNotifications 0 2 }
xcvrMismatchCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a mismatch between the SFP or XFP transceiver
provisioned for a port of a circuit pack and the physical SFP
or XFP transceiver that is inserted in the port. The
provisioned SFP or XFP transceiver must match the transceiver
in the port."
::= { xcvrCondNotifications 0 3 }
xcvrMismatchClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active transceiver port type mismatch condition
has cleared."
::= { xcvrCondNotifications 0 4 }
xcvrRFICond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Remote Fault Indication: The source port to which the
specified destination transceiver port is cross-connected has
a service-affecting fault active against it."
::= { xcvrCondNotifications 0 5 }
xcvrRFIClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active transceiver RFI condition has cleared."
::= { xcvrCondNotifications 0 6 }
xcvrLossOfSignalCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that an SFP transceiver has experienced
an input power drop that is below the preset minimum
threshold."
::= { xcvrCondNotifications 0 7 }
xcvrLossOfSignalClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active transceiver port Loss Of Signal condition
has cleared."
::= { xcvrCondNotifications 0 8 }
xcvrLossOfLockCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that a transceiver port is unable to lock
on the incoming bit stream. This is a result of either: the
provisioned protocol does not match the incoming signal, or
the incoming signal is excessively degraded."
::= { xcvrCondNotifications 0 9 }
xcvrLossOfLockClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active transceiver port Loss Of Lock condition
has cleared."
::= { xcvrCondNotifications 0 10 }
xcvrOpticalPwrReceivedMinCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
xcvrOpticalPwrReceived,
xcvrOpticalPwrReceivedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The optical power received (OPR) low threshold is not met. The
input signal to a transceiver has reached the optical power
received low threshold. If the input signal drops to below the
input sensitivity level, the transceiver degrades in
performance."
::= { xcvrCondNotifications 0 11 }
xcvrOpticalPwrReceivedMinClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active transceiver port minimum power received
condition has cleared."
::= { xcvrCondNotifications 0 12 }
xcvrOpticalPwrReceivedMaxCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
xcvrOpticalPwrReceived,
xcvrOpticalPwrReceivedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The optical power received (OPR) high threshold is exceeded.
The input signal to a transceiver has reached the optical
power received high threshold."
::= { xcvrCondNotifications 0 13 }
xcvrOpticalPwrReceivedMaxClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active transceiver port maximum power received
condition has cleared."
::= { xcvrCondNotifications 0 14 }
xcvrOpticalPwrTransmittedMinCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
xcvrOpticalPwrTransmitted,
xcvrOpticalPwrTransmittedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The optical power transmitted (OPT) is below the low threshold
for the transceiver."
::= { xcvrCondNotifications 0 15 }
xcvrOpticalPwrTransmittedMinClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active transceiver port minimum power transmitted
condition has cleared."
::= { xcvrCondNotifications 0 16 }
xcvrOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
xcvrOpticalPwrTransmitted,
xcvrOpticalPwrTransmittedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The optical power transmitted (OPT) high threshold for a
transceiver is exceeded."
::= { xcvrCondNotifications 0 17 }
xcvrOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active transceiver port maximum power transmitted
condition has cleared."
::= { xcvrCondNotifications 0 18 }
xcvrLossOfFrameCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A transceiver reports a SONET or SDH loss of frame for a
transceiver that is provisioned to receive a SONET or SDH
protocol."
::= { xcvrCondNotifications 0 19 }
xcvrLossOfFrameClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active loss of frame condition has cleared."
::= { xcvrCondNotifications 0 20 }
xcvrLossOfSyncCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that a loss of synchronization condition has been
detected by the transceiver port on the incoming gigabit
ethernet or 10GELAN protocol."
::= { xcvrCondNotifications 0 21 }
xcvrLossOfSyncClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active loss of synchronization condition has
cleared."
::= { xcvrCondNotifications 0 22 }
xcvrLoopbackCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the transceiver has been provisioned to enter
loopback mode."
::= { xcvrCondNotifications 0 27 }
xcvrLoopbackClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active loopback condition on the transceiver has
been cleared."
::= { xcvrCondNotifications 0 28 }
xcvrForcedSwitchToProtectionCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The active transceiver of a protected transceiver pair has
been forced to switch to the Protection transceiver."
::= { xcvrCondNotifications 0 29 }
xcvrForcedSwitchToProtectionClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Forced Switch To Protection condition has
cleared."
::= { xcvrCondNotifications 0 30 }
xcvrForcedSwitchToWorkingCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The active transceiver of a protected transceiver pair has
been forced to switch to the Working transceiver."
::= { xcvrCondNotifications 0 31 }
xcvrForcedSwitchToWorkingClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Forced Switch To Working condition has
cleared."
::= { xcvrCondNotifications 0 32 }
xcvrLockoutProtectionCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Protection transceiver of a protected transceiver pair has
been locked out."
::= { xcvrCondNotifications 0 33 }
xcvrLockoutProtectionClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Lockout Protection condition has cleared."
::= { xcvrCondNotifications 0 34 }
xcvrLockoutWorkingCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Working transceiver of a protected transceiver pair has
been locked out."
::= { xcvrCondNotifications 0 35 }
xcvrLockoutWorkingClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Lockout Working condition has cleared."
::= { xcvrCondNotifications 0 36 }
xcvrTempMaxCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the temperature of the physical transceiver has
risen above the maximum threshold."
::= { xcvrCondNotifications 0 37 }
xcvrTempMaxClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Temperature Exceeded Maximum condition has
cleared."
::= { xcvrCondNotifications 0 38 }
xcvrWavelengthNotAchievableCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the transceiver is not currently able to tune
to the set wavelength."
::= { xcvrCondNotifications 0 39 }
xcvrWavelengthNotAchievableClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Wavelength Not Achievable condition has
cleared."
::= { xcvrCondNotifications 0 40 }
xcvrAlarmIndicationSignalCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An Alarm Indication Signal indication is active on the
transceiver port."
::= { xcvrCondNotifications 0 41 }
xcvrAlarmIndicationSignalClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Alarm Indication Signal condition has
cleared."
::= { xcvrCondNotifications 0 42 }
xcvrTraceMismatchCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
xcvrReceivedTraceLabel,
xcvrExpectedTraceLabel,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This condition indicates that the received trace label on the
transciever port does not match the expected trace label."
::= { xcvrCondNotifications 0 43 }
xcvrTraceMismatchClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Trace Mismatch condition has cleared."
::= { xcvrCondNotifications 0 44 }
xcvrRemoteFaultCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A remote fault indication is active on the traceiver port."
::= { xcvrCondNotifications 0 45 }
xcvrRemoteFaultClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised remote fault indication has cleared."
::= { xcvrCondNotifications 0 46 }
xcvrSignalDegradeCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Signal Degrade BER threshold has been crossed on the
transiever port."
::= { xcvrCondNotifications 0 47 }
xcvrSignalDegradeClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Signal Degrade condition has cleared."
::= { xcvrCondNotifications 0 48 }
xcvrOTNPayloadMismatchCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An OTN payload mismatch is active on the transceiver port
facility."
::= { xcvrCondNotifications 0 49 }
xcvrOTNPayloadMismatchClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OTN payload mismatch condition on the
transceiver port facility has cleared."
::= { xcvrCondNotifications 0 50 }
xcvrLFCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Local Failure: Raised when a port detects and incoming local
failure indication is received."
::= { xcvrCondNotifications 0 51 }
xcvrLFClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active transceiver LF condition has cleared."
::= { xcvrCondNotifications 0 52 }
xcvrOpenConnectionIndicatorCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An Open Connection Indicator is active on the
transceiver port."
::= { xcvrCondNotifications 0 53 }
xcvrOpenConnectionIndicatorClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Open Connection Indicator condition has
cleared."
::= { xcvrCondNotifications 0 54 }
xcvrReceivedLockoutCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Received Lockout indication is active on the
transceiver port."
::= { xcvrCondNotifications 0 55 }
xcvrReceivedLockoutClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Received Lockout condition has
cleared."
::= { xcvrCondNotifications 0 56 }
xcvrBackwardDefectIndicatorCond NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Backward Defect Indicator is active on the
transceiver port."
::= { xcvrCondNotifications 0 57 }
xcvrBackwardDefectIndicatorClear NOTIFICATION-TYPE
OBJECTS { xcvrTypeIdx,
xcvrShelfIdx,
xcvrSlotIdx,
xcvrIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Backward Defect Indicator condition has
cleared."
::= { xcvrCondNotifications 0 58 }
amdLossOfSignalCond NOTIFICATION-TYPE
OBJECTS { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "This condition indicates that an active mux/demux that has
experienced an input power drop that is below the preset
threshold. This can be against either a channel or the
composite line port."
::= { amdCondNotifications 0 1 }
amdLossOfSignalClear NOTIFICATION-TYPE
OBJECTS { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "A previously raised active multiplexer-demultiplexer loss of
signal condition has cleared."
::= { amdCondNotifications 0 2 }
amdOpticalPwrReceivedMinCond NOTIFICATION-TYPE
OBJECTS { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx,
amdOpticalPwrReceived,
amdOpticalPwrReceivedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "Indicates that the input power for the active
multiplexer-demultiplexer facility has fallen below the
minimum threshold."
::= { amdCondNotifications 0 3 }
amdOpticalPwrReceivedMinClear NOTIFICATION-TYPE
OBJECTS { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "A previously raised active multiplexer-demultiplexer minimum
power received condition has cleared."
::= { amdCondNotifications 0 4 }
amdOpticalPwrReceivedMaxCond NOTIFICATION-TYPE
OBJECTS { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx,
amdOpticalPwrReceived,
amdOpticalPwrReceivedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "Indicates that the input power for the active
multiplexer-demultiplexer facility has risen above the maximum
threshold."
::= { amdCondNotifications 0 5 }
amdOpticalPwrReceivedMaxClear NOTIFICATION-TYPE
OBJECTS { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "A previously raised active multiplexer-demultiplexer maximum
power received condition has cleared."
::= { amdCondNotifications 0 6 }
amdTPLNACond NOTIFICATION-TYPE
OBJECTS { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx,
amdOpticalPwrTransmitted,
amdOpticalPwrTransmittedTarget,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "A channel target power level not achieved (TPLNA) condition is
triggered when the output power for a channel of a 32-Channel
DWDM Active Mux/Demux (D32AMD) module is above or below the
target power transmitted level for that channel."
::= { amdCondNotifications 0 7 }
amdTPLNAClear NOTIFICATION-TYPE
OBJECTS { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "A previously raised active target power level not achieved
condition has been cleared."
::= { amdCondNotifications 0 8 }
amdTALNACond NOTIFICATION-TYPE
OBJECTS { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx,
amdOpticalAttentuation,
amdOpticalAttenuationTarget,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "The target attenuation level not achieved (TALNA) condition is
triggered when the attenuation for a 32-Channel DWDM Active
Mux/Demux (D32AMD) is outside the preset attenuation levels
for a composite line."
::= { amdCondNotifications 0 9 }
amdTALNAClear NOTIFICATION-TYPE
OBJECTS { amdTypeIdx,
amdShelfIdx,
amdSlotIdx,
amdLineIdx,
amdPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS obsolete
DESCRIPTION "A previously raised active target attenuation level not
achieved condition has been cleared."
::= { amdCondNotifications 0 10 }
ocnLossOfSignalCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This notification indicates that there is no input signal
detected on the OC-N port."
::= { ocnCondNotifications 0 1 }
ocnLossOfSignalClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This notification indicates that a previously active OC-N Loss
of Signal condition has been cleared."
::= { ocnCondNotifications 0 2 }
ocnXcvrMismatchCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a mismatch between the SFP or XFP transceiver
provisioned for the OC-N facility port and the physical
transceiver that is inserted in the port. The SFP or XFP
transceiver in the port must match the attributes provisioned
for the OC-N facility."
::= { ocnCondNotifications 0 3 }
ocnXcvrMismatchClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OC-N Mismatch condition has cleared."
::= { ocnCondNotifications 0 4 }
ocnOpticalPwrReceivedMinCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
ocnOpticalPwrReceived,
ocnOpticalPwrReceivedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the input power for the OC-N facility has
fallen below the minimum threshold."
::= { ocnCondNotifications 0 5 }
ocnOpticalPwrReceivedMinClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OC-N minimum power recieved condition has
cleared."
::= { ocnCondNotifications 0 6 }
ocnOpticalPwrReceivedMaxCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
ocnOpticalPwrReceived,
ocnOpticalPwrReceivedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the input power for the OC-N facility has risen
above the maximum threshold."
::= { ocnCondNotifications 0 7 }
ocnOpticalPwrReceivedMaxClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OC-N maximum power recieved condition has
cleared."
::= { ocnCondNotifications 0 8 }
ocnOpticalPwrTransmittedMinCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
ocnOpticalPwrTransmitted,
ocnOpticalPwrTransmittedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the output power for the OC-N facility has
fallen below the minimum threshold."
::= { ocnCondNotifications 0 9 }
ocnOpticalPwrTransmittedMinClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OC-N minimum power transmitted condition
has cleared."
::= { ocnCondNotifications 0 10 }
ocnOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
ocnOpticalPwrTransmitted,
ocnOpticalPwrTransmittedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the output power for the OC-N facility has
risen above the maximum threshold."
::= { ocnCondNotifications 0 11 }
ocnOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OC-N maximum power transmitted condition
has cleared."
::= { ocnCondNotifications 0 12 }
ocnLossOfFrameCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An OC-N Loss of Frame condition is active on the port."
::= { ocnCondNotifications 0 13 }
ocnLossOfFrameClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OC-N Loss of Frame condition has cleared."
::= { ocnCondNotifications 0 14 }
ocnSignalDegradeCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
ocnBER,
ocnBERTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A signal degrade condition on the OC-N facility is active.
This indicates that the detected bit error rate exceeds the
degrade threshold."
::= { ocnCondNotifications 0 15 }
ocnSignalDegradeClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OC-N Signal Degrade condition has
cleared."
::= { ocnCondNotifications 0 16 }
ocnAlarmIndicationSignalCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An OC-N Line-level Alarm Indication Signal indication is
active on facility."
::= { ocnCondNotifications 0 17 }
ocnAlarmIndicationSignalClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OC-N Alarm Indication Signal condition has
cleared."
::= { ocnCondNotifications 0 18 }
ocnLoopbackCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the OC-N facility has been provisioned to enter
loopback mode."
::= { ocnCondNotifications 0 19 }
ocnLoopbackClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active loopback condition on the OC-N facility
has been cleared."
::= { ocnCondNotifications 0 20 }
ocnLossOfPrimaryTimingReferenceCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the primary timing reference signal for the
identified OC-N facility is missing or faulty and cannot be
locked on."
::= { ocnCondNotifications 0 21 }
ocnLossOfPrimaryTimingReferenceClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OC-N Loss of Primary Timing Reference
condition has cleared."
::= { ocnCondNotifications 0 22 }
ocnLossOfSecondaryTimingReferenceCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the secondary timing reference signal for the
identified OC-N facility is missing or faulty and cannot be
locked on."
::= { ocnCondNotifications 0 23 }
ocnLossOfSecondaryTimingReferenceClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OC-N Loss of Secondary Timing Reference
condition has cleared."
::= { ocnCondNotifications 0 24 }
ocnOTNPayloadMismatchCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An OTN payload mismatch is active on the facility."
::= { ocnCondNotifications 0 25 }
ocnOTNPayloadMismatchClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OTN payload mismatch condition has
cleared."
::= { ocnCondNotifications 0 26 }
ocnForcedSwitchToProtectionCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The active line of a protected line pair has
been forced to switch to the Protection line."
::= { ocnCondNotifications 0 27 }
ocnForcedSwitchToProtectionClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Forced Switch To Protection condition has
cleared."
::= { ocnCondNotifications 0 28 }
ocnForcedSwitchToWorkingCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The active line of a protected line pair has
been forced to switch to the Working line."
::= { ocnCondNotifications 0 29 }
ocnForcedSwitchToWorkingClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Forced Switch To Working condition has
cleared."
::= { ocnCondNotifications 0 30 }
ocnLockoutProtectionCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Protection line of a protected line pair has
been locked out."
::= { ocnCondNotifications 0 31 }
ocnLockoutProtectionClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Lockout Protection condition has cleared."
::= { ocnCondNotifications 0 32 }
ocnLockoutWorkingCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Working line of a protected line pair has
been locked out."
::= { ocnCondNotifications 0 33 }
ocnLockoutWorkingClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Lockout Working condition has cleared."
::= { ocnCondNotifications 0 34 }
ocnWavelengthNotAchievableCond NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The tunable pluggable cannot be tuned to the provisioned wavelength."
::= { ocnCondNotifications 0 35 }
ocnWavelengthNotAchievableClear NOTIFICATION-TYPE
OBJECTS { ocnTypeIdx,
ocnShelfIdx,
ocnSlotIdx,
ocnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Wavelength Not Achievable condition has
cleared."
::= { ocnCondNotifications 0 36 }
stsnAlarmIndicationSignalCond NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Path-level Alarm Indication Signal indication is active on
the STS-N channel."
::= { stsnCondNotifications 0 1 }
stsnAlarmIndicationSignalClear NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active STS-N Alarm Indication Signal condition
has cleared."
::= { stsnCondNotifications 0 2 }
stsnLossOfPointerCond NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Loss of Pointer condition is active on the STS-N channel."
::= { stsnCondNotifications 0 3 }
stsnLossOfPointerClear NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised STS-N Loss of Pointer condition has
cleared."
::= { stsnCondNotifications 0 4 }
stsnUnequippedCond NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An Unequipped indication has been detected for the STS-N
channel."
::= { stsnCondNotifications 0 5 }
stsnUnequippedClear NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised STS-N Unequipped condition has cleared."
::= { stsnCondNotifications 0 6 }
stsnSignalDegradeCond NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
stsnBER,
stsnBERTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A signal degrade condition on the STS-N channel is active.
This indicates that the detected bit error rate exceeds the
degrade threshold."
::= { stsnCondNotifications 0 7 }
stsnSignalDegradeClear NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised STS-N signal degrade condition has
cleared."
::= { stsnCondNotifications 0 8 }
stsnForcedSwitchToProtectionCond NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The active STS-N channel of a protected STS-N channel pair has
been forced to switch to the Protection transceiver."
::= { stsnCondNotifications 0 9 }
stsnForcedSwitchToProtectionClear NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised STS-N Forced Switch To Protection
condition has cleared."
::= { stsnCondNotifications 0 10 }
stsnForcedSwitchToWorkingCond NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The active STS-N channel of a protected STS-N channel pair has
been forced to switch to the Working transceiver."
::= { stsnCondNotifications 0 11 }
stsnForcedSwitchToWorkingClear NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised STS-N Forced Switch To Working condition
has cleared."
::= { stsnCondNotifications 0 12 }
stsnLockoutProtectionCond NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Protection STS-N channel of a protected STS-N channel pair
has been locked out."
::= { stsnCondNotifications 0 13 }
stsnLockoutProtectionClear NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised STS-N Lockout Protection condition has
cleared."
::= { stsnCondNotifications 0 14 }
stsnLockoutWorkingCond NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Working STS-N channel of a protected STS-N channel pair
has been locked out."
::= { stsnCondNotifications 0 15 }
stsnLockoutWorkingClear NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised STS-N Lockout Working condition has
cleared."
::= { stsnCondNotifications 0 16 }
stsnConcatMismatchCond NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A connection provisioning does not match has been detected for
the STS-N channel."
::= { stsnCondNotifications 0 17 }
stsnConcatMismatchClear NOTIFICATION-TYPE
OBJECTS { stsnTypeIdx,
stsnShelfIdx,
stsnSlotIdx,
stsnPortIdx,
stsnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised STS-N Concat Mismatch condition has
cleared."
::= { stsnCondNotifications 0 18 }
stmnLossOfSignalCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This notification indicates that there is no input signal
detected on the STM-N port."
::= { stmnCondNotifications 0 1 }
stmnLossOfSignalClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This notification indicates that a previously active STM-N
Loss of Signal condition has been cleared."
::= { stmnCondNotifications 0 2 }
stmnXcvrMismatchCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a mismatch between the SFP or XFP transceiver
provisioned for the STM-N facility port and the physical
transceiver that is inserted in the port. The SFP or XFP
transceiver in the port must match the attributes provisioned
for the STM-N facility."
::= { stmnCondNotifications 0 3 }
stmnXcvrMismatchClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active STM-N Mismatch condition has cleared."
::= { stmnCondNotifications 0 4 }
stmnOpticalPwrReceivedMinCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
stmnOpticalPwrReceived,
stmnOpticalPwrReceivedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the input power for the STM-N facility has
fallen below the minimum threshold."
::= { stmnCondNotifications 0 5 }
stmnOpticalPwrReceivedMinClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active STM-N minimum power recieved condition has
cleared."
::= { stmnCondNotifications 0 6 }
stmnOpticalPwrReceivedMaxCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
stmnOpticalPwrReceived,
stmnOpticalPwrReceivedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the input power for the STM-N facility has
risen above the maximum threshold."
::= { stmnCondNotifications 0 7 }
stmnOpticalPwrReceivedMaxClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active STM-N maximum power recieved condition has
cleared."
::= { stmnCondNotifications 0 8 }
stmnOpticalPwrTransmittedMinCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
stmnOpticalPwrTransmitted,
stmnOpticalPwrTransmittedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the output power for the STM-N facility has
fallen below the minimum threshold."
::= { stmnCondNotifications 0 9 }
stmnOpticalPwrTransmittedMinClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active STM-N minimum power transmitted condition
has cleared."
::= { stmnCondNotifications 0 10 }
stmnOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
stmnOpticalPwrTransmitted,
stmnOpticalPwrTransmittedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the output power for the STM-N facility has
risen above the maximum threshold."
::= { stmnCondNotifications 0 11 }
stmnOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active STM-N maximum power transmitted condition
has cleared."
::= { stmnCondNotifications 0 12 }
stmnLossOfFrameCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An STM-N Loss of Frame condition is active on the port."
::= { stmnCondNotifications 0 13 }
stmnLossOfFrameClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active STM-N Loss of Frame condition has
cleared."
::= { stmnCondNotifications 0 14 }
stmnSignalDegradeCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
stmnBER,
stmnBERTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A signal degrade condition on the STM-N facility is active.
This indicates that the detected bit error rate exceeds the
degrade threshold."
::= { stmnCondNotifications 0 15 }
stmnSignalDegradeClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active STM-N Signal Degrade condition has
cleared."
::= { stmnCondNotifications 0 16 }
stmnAlarmIndicationSignalCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An STM-N Line-level Alarm Indication Signal indication is
active on facility."
::= { stmnCondNotifications 0 17 }
stmnAlarmIndicationSignalClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active STM-N Alarm Indication Signal condition
has cleared."
::= { stmnCondNotifications 0 18 }
stmnLoopbackCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the STM-N facility has been provisioned to
enter loopback mode."
::= { stmnCondNotifications 0 19 }
stmnLoopbackClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active loopback condition on the STM-N facility
has been cleared."
::= { stmnCondNotifications 0 20 }
stmnLossOfPrimaryTimingReferenceCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the primary timing reference signal for the
identified STM-N facility is missing or faulty and cannot be
locked on."
::= { stmnCondNotifications 0 21 }
stmnLossOfPrimaryTimingReferenceClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active STM-N Loss of Primary Timing Reference
condition has cleared."
::= { stmnCondNotifications 0 22 }
stmnLossOfSecondaryTimingReferenceCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the secondary timing reference signal for the
identified STM-N facility is missing or faulty and cannot be
locked on."
::= { stmnCondNotifications 0 23 }
stmnLossOfSecondaryTimingReferenceClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active STM-N Loss of Secondary Timing Reference
condition has cleared."
::= { stmnCondNotifications 0 24 }
stmnOTNPayloadMismatchCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An OTN payload mismatch is active on the facility."
::= { stmnCondNotifications 0 25 }
stmnOTNPayloadMismatchClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active OTN payload mismatch condition has
cleared."
::= { stmnCondNotifications 0 26 }
stmnForcedSwitchToProtectionCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The active line of a protected line pair has
been forced to switch to the Protection line."
::= { stmnCondNotifications 0 27 }
stmnForcedSwitchToProtectionClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Forced Switch To Protection condition has
cleared."
::= { stmnCondNotifications 0 28 }
stmnForcedSwitchToWorkingCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The active line of a protected line pair has
been forced to switch to the Working line."
::= { stmnCondNotifications 0 29 }
stmnForcedSwitchToWorkingClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Forced Switch To Working condition has
cleared."
::= { stmnCondNotifications 0 30 }
stmnLockoutProtectionCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Protection line of a protected line pair has
been locked out."
::= { stmnCondNotifications 0 31 }
stmnLockoutProtectionClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Lockout Protection condition has cleared."
::= { stmnCondNotifications 0 32 }
stmnLockoutWorkingCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Working line of a protected line pair has
been locked out."
::= { stmnCondNotifications 0 33 }
stmnLockoutWorkingClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Lockout Working condition has cleared."
::= { stmnCondNotifications 0 34 }
stmnWavelengthNotAchievableCond NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Wavelength Not Achievable condition has cleared."
::= { stmnCondNotifications 0 35 }
stmnWavelengthNotAchievableClear NOTIFICATION-TYPE
OBJECTS { stmnTypeIdx,
stmnShelfIdx,
stmnSlotIdx,
stmnPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Lockout Working condition has cleared."
::= { stmnCondNotifications 0 36 }
vcnAlarmIndicationSignalCond NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Path-level Alarm Indication Signal indication is active on
the VC-N channel."
::= { vcnCondNotifications 0 1 }
vcnAlarmIndicationSignalClear NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active VC-N Alarm Indication Signal condition has
cleared."
::= { vcnCondNotifications 0 2 }
vcnLossOfPointerCond NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Loss of Pointer condition is active on the VC-N channel."
::= { vcnCondNotifications 0 3 }
vcnLossOfPointerClear NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised VC-N Loss of Pointer condition has
cleared."
::= { vcnCondNotifications 0 4 }
vcnUnequippedCond NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An Unequipped indication has been detected for the VC-N
channel."
::= { vcnCondNotifications 0 5 }
vcnUnequippedClear NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised VC-N Unequipped condition has cleared."
::= { vcnCondNotifications 0 6 }
vcnSignalDegradeCond NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
vcnBER,
vcnBERTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A signal degrade condition on the VC-N channel is active. This
indicates that the detected bit error rate exceeds the degrade
threshold."
::= { vcnCondNotifications 0 7 }
vcnSignalDegradeClear NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised VC-N signal degrade condition has
cleared."
::= { vcnCondNotifications 0 8 }
vcnForcedSwitchToProtectionCond NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The active VC-N channel of a protected VC-N channel pair has
been forced to switch to the Protection transceiver."
::= { vcnCondNotifications 0 9 }
vcnForcedSwitchToProtectionClear NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised VC-N Forced Switch To Protection condition
has cleared."
::= { vcnCondNotifications 0 10 }
vcnForcedSwitchToWorkingCond NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The active VC-N channel of a protected VC-N channel pair has
been forced to switch to the Working transceiver."
::= { vcnCondNotifications 0 11 }
vcnForcedSwitchToWorkingClear NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised VC-N Forced Switch To Working condition
has cleared."
::= { vcnCondNotifications 0 12 }
vcnLockoutProtectionCond NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Protection VC-N channel of a protected VC-N channel pair
has been locked out."
::= { vcnCondNotifications 0 13 }
vcnLockoutProtectionClear NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised VC-N Lockout Protection condition has
cleared."
::= { vcnCondNotifications 0 14 }
vcnLockoutWorkingCond NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "The Working VC-N channel of a protected VC-N channel pair has
been locked out."
::= { vcnCondNotifications 0 15 }
vcnLockoutWorkingClear NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised VC-N Lockout Working condition has
cleared."
::= { vcnCondNotifications 0 16 }
vcnConcatMismatchCond NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A connection provisioning does not match has been detected for
the VC-N channel."
::= { vcnCondNotifications 0 17 }
vcnConcatMismatchClear NOTIFICATION-TYPE
OBJECTS { vcnTypeIdx,
vcnShelfIdx,
vcnSlotIdx,
vcnPortIdx,
vcnIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised VC-N Concat Mismatch condition has
cleared."
::= { vcnCondNotifications 0 18 }
geLossOfSignalCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This notification indicates that there is no input signal
detected on the Gigabit Ethernet port."
::= { geCondNotifications 0 1 }
geLossOfSignalClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This notification indicates that a previously active GE Loss
of Signal condition has been cleared."
::= { geCondNotifications 0 2 }
geXcvrMismatchCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a mismatch between the SFP or XFP transceiver
provisioned for the Gigabit Ethernet facility port and the
physical transceiver that is inserted in the port. The SFP or
XFP transceiver in the port must match the attributes
provisioned for the GE facility."
::= { geCondNotifications 0 3 }
geXcvrMismatchClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active GE Mistmatch condition has cleared."
::= { geCondNotifications 0 4 }
geOpticalPwrReceivedMinCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
geOpticalPwrReceived,
geOpticalPwrReceivedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the input power for the Gigabit Ethernet
facility has fallen below the minimum threshold."
::= { geCondNotifications 0 5 }
geOpticalPwrReceivedMinClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active GE minimum power recieved condition has
cleared."
::= { geCondNotifications 0 6 }
geOpticalPwrReceivedMaxCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
geOpticalPwrReceived,
geOpticalPwrReceivedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the input power for the Gigabity Ethernet
facility has risen above the maximum threshold."
::= { geCondNotifications 0 7 }
geOpticalPwrReceivedMaxClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active GE maximum power recieved condition has
cleared."
::= { geCondNotifications 0 8 }
geOpticalPwrTransmittedMinCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
geOpticalPwrTransmitted,
geOpticalPwrTransmittedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the output power for the Gigabit Ethernet
facility has fallen below the minimum threshold."
::= { geCondNotifications 0 9 }
geOpticalPwrTransmittedMinClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active GE minimum power transmitted condition has
cleared."
::= { geCondNotifications 0 10 }
geOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
geOpticalPwrTransmitted,
geOpticalPwrTransmittedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the output power for the Gigabit Ethernet
facility has risen above the maximum threshold."
::= { geCondNotifications 0 11 }
geOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active GE maximum power transmitted condition has
cleared."
::= { geCondNotifications 0 12 }
geLossOfSyncCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Gigabit Ethernet Loss of Synchronization condition is active
on the port."
::= { geCondNotifications 0 13 }
geLossOfSyncClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Gigabit Ethernet Loss of Synchronization
condition has cleared."
::= { geCondNotifications 0 14 }
geRemotePathFailureCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Gigabit Ethernet Remote Path Failure condition is active on
the port."
::= { geCondNotifications 0 15 }
geRemotePathFailureClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active GE Remote Path Failure condition has
cleared."
::= { geCondNotifications 0 16 }
geLossOfMultiframeCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Loss of Multiframe condition is active against the VCG that
is mapped to the identified Gigabit Ethernet port."
::= { geCondNotifications 0 17 }
geLossOfMultiframeClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised GE Loss of Multiframe condition has
cleared."
::= { geCondNotifications 0 18 }
geLossOfSequenceCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Loss of Sequence condition is active against the VCG that is
mapped to the identified Gigabit Ethernet port."
::= { geCondNotifications 0 19 }
geLossOfSequenceClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active GE Loss of Sequence condition has
cleared."
::= { geCondNotifications 0 20 }
geLossOfAlignmentCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Loss of Alignment condition is active against the VCG that
is mapped to the identified Gigabit Ethernet port."
::= { geCondNotifications 0 21 }
geLossOfAlignmentClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active GE Loss of Alignment condition has
cleared."
::= { geCondNotifications 0 22 }
geLoopbackCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the Gigabit Ethernet facility has been
provisioned to enter loopback mode."
::= { geCondNotifications 0 23 }
geLoopbackClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active GE Loopback condition has cleared."
::= { geCondNotifications 0 24 }
geBandwidthMismatchCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A GE bandwidth mismatch condition is active on the port."
::= { geCondNotifications 0 25 }
geBandwidthMismatchClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active GE bandwidth mismatch condition has
cleared."
::= { geCondNotifications 0 26 }
gePayloadMismatchCond NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A GE payload mismatch condition is active on the port."
::= { geCondNotifications 0 27 }
gePayloadMismatchClear NOTIFICATION-TYPE
OBJECTS { geShelfIdx,
geSlotIdx,
gePortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active GE payload mismatch condition has
cleared."
::= { geCondNotifications 0 28 }
fcLossOfSignalCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This notification indicates that there is no input signal
detected on the Fiber Channel port."
::= { fcCondNotifications 0 1 }
fcLossOfSignalClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This notification indicates that a previously active FC Loss
of Signal condition has been cleared."
::= { fcCondNotifications 0 2 }
fcXcvrMismatchCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a mismatch between the SFP or XFP transceiver
provisioned for the Fiber Channel facility port and the
physical transceiver that is inserted in the port. The SFP or
XFP transceiver in the port must match the attributes
provisioned for the FC facility."
::= { fcCondNotifications 0 3 }
fcXcvrMismatchClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active FC XCVR Mistmatch condition has cleared."
::= { fcCondNotifications 0 4 }
fcOpticalPwrReceivedMinCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
fcOpticalPwrReceived,
fcOpticalPwrReceivedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the input power for the Fiber Channel facility
has fallen below the minimum threshold."
::= { fcCondNotifications 0 5 }
fcOpticalPwrReceivedMinClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active FC minimum power recieved condition has
cleared."
::= { fcCondNotifications 0 6 }
fcOpticalPwrReceivedMaxCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
fcOpticalPwrReceived,
fcOpticalPwrReceivedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the input power for the Fiber Channel facility
has risen above the maximum threshold."
::= { fcCondNotifications 0 7 }
fcOpticalPwrReceivedMaxClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active FC maximum power recieved condition has
cleared."
::= { fcCondNotifications 0 8 }
fcOpticalPwrTransmittedMinCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
fcOpticalPwrTransmitted,
fcOpticalPwrTransmittedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the output power for the Fiber Channel facility
has fallen below the minimum threshold."
::= { fcCondNotifications 0 9 }
fcOpticalPwrTransmittedMinClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active FC minimum power transmitted condition has
cleared."
::= { fcCondNotifications 0 10 }
fcOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
fcOpticalPwrTransmitted,
fcOpticalPwrTransmittedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the output power for the Fiber Channel facility
has risen above the maximum threshold."
::= { fcCondNotifications 0 11 }
fcOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active FC maximum power transmitted condition has
cleared."
::= { fcCondNotifications 0 12 }
fcLossOfSyncCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Fiber Channel Loss of Synchronization condition is active on
the port."
::= { fcCondNotifications 0 13 }
fcLossOfSyncClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Fiber Channel Loss of Synchronization
condition has cleared."
::= { fcCondNotifications 0 14 }
fcRemotePathFailureCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Fiber Channel Remote Path Failure condition is active on the
port."
::= { fcCondNotifications 0 15 }
fcRemotePathFailureClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active FC Remote Path Failure condition has
cleared."
::= { fcCondNotifications 0 16 }
fcLossOfMultiframeCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Loss of Multiframe condition is active against the VCG that
is mapped to the identified Fiber Channel port."
::= { fcCondNotifications 0 17 }
fcLossOfMultiframeClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised FC Loss of Multiframe condition has
cleared."
::= { fcCondNotifications 0 18 }
fcLossOfSequenceCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Loss of Sequence condition is active against the VCG that is
mapped to the identified Fiber Channel port."
::= { fcCondNotifications 0 19 }
fcLossOfSequenceClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active FC Loss of Sequence condition has
cleared."
::= { fcCondNotifications 0 20 }
fcLossOfAlignmentCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Loss of Alignment condition is active against the VCG that
is mapped to the identified Fiber Channel port."
::= { fcCondNotifications 0 21 }
fcLossOfAlignmentClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active FC Loss of Alignment condition has
cleared."
::= { fcCondNotifications 0 22 }
fcLoopbackCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the Fiber Channel facility has been provisioned
to enter loopback mode."
::= { fcCondNotifications 0 23 }
fcLoopbackClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active FC Loopback condition has cleared."
::= { fcCondNotifications 0 24 }
fcBandwidthMismatchCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Fiber Channel bandwidth mismatch condition is active on the
port."
::= { fcCondNotifications 0 25 }
fcBandwidthMismatchClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Fiber Channel bandwidth mismatch condition
has cleared."
::= { fcCondNotifications 0 26 }
fcPayloadMismatchCond NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Fiber Channel payload mismatch condition is active on the
port."
::= { fcCondNotifications 0 27 }
fcPayloadMismatchClear NOTIFICATION-TYPE
OBJECTS { fcShelfIdx,
fcSlotIdx,
fcPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active Fiber Channel payload mismatch condition
has cleared."
::= { fcCondNotifications 0 28 }
tl1UserLockoutCond NOTIFICATION-TYPE
OBJECTS { tl1UserIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A user is locked out of the system. After three incorrect
attempts to login, a user is blocked from attempting to login
again for 60 seconds."
::= { adminCondNotifications 0 1 }
tl1UserLockoutClear NOTIFICATION-TYPE
OBJECTS { tl1UserIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active TL1 User Lockout condition has cleared."
::= { adminCondNotifications 0 2 }
tl1IpLockoutCond NOTIFICATION-TYPE
OBJECTS { tl1IpLockoutAddr,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "After three incorrect attempts to login from the same IP
address, the IP address from which the three attempts are made
is blocked for 60 seconds. When this condition is present in
the actCondTable, the actCondTableEntryIdx will be set to the
networkElement OID and the actCondInstanceIdx will be set to
0."
::= { adminCondNotifications 0 3 }
tl1IpLockoutClear NOTIFICATION-TYPE
OBJECTS { tl1IpLockoutAddr,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting ,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active TL1 IP lockout condition has cleared."
::= { adminCondNotifications 0 4 }
----------------------------------------------
-- L1 ethernet port alarms
----------------------------------------------
olsSFPMissingCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 1 }
olsSFPMissingClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 2 }
olsSFPMismatchCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 3 }
olsSFPMismatchClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 4 }
olsInputLOSCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 5 }
olsInputLOSClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 6 }
olsOpticalPwrReceivedMinCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 7 }
olsOpticalPwrReceivedMinClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 8 }
olsOpticalPwrReceivedMaxCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 9 }
olsOpticalPwrReceivedMaxClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 10 }
olsOpticalPwrTransmittedMinCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 11 }
olsOpticalPwrTransmittedMinClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 12 }
olsOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 13 }
olsOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 14 }
olsTemperatureMaxCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 15 }
olsTemperatureMaxClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 16 }
olsLoopbackCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 17 }
olsLoopbackClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 18 }
olsLossOfSyncCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 19 }
olsLossOfSyncClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 20 }
olsLossOfFrameCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 21 }
olsLossOfFrameClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 22 }
olsAlarmIndicationSignalCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 23 }
olsAlarmIndicationSignalClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 24 }
olsBackwardDefectIndicatorCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 25 }
olsBackwardDefectIndicatorClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 26 }
olsSignalDegradeCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 27 }
olsSignalDegradeClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 28 }
olsOTNPayloadMismatchCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 29 }
olsOTNPayloadMismatchClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 30 }
olsOTUTrailTraceMismatchCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 31 }
olsOTUTrailTraceMismatchClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 32 }
olsRemoteFaultCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A remote fault indication is active on the ethernet interface."
::= { ethPortCondNotifications 0 33 }
olsRemoteFaultClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised remote fault indication has cleared."
::= { ethPortCondNotifications 0 34 }
olsLocalFaultCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A local fault indication is active on the ethernet interface."
::= { ethPortCondNotifications 0 35 }
olsLocalFaultClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised local fault indication has cleared."
::= { ethPortCondNotifications 0 36 }
olsWavelengthNotAchievableCond NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 37 }
olsWavelengthNotAchievableClear NOTIFICATION-TYPE
OBJECTS { ethIntfShelfIdx,
ethIntfSlotIdx,
ethIntfPortTypeIdx,
ethIntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION ""
::= { ethPortCondNotifications 0 38 }
--------------------------------------
-- L2 alarms
--------------------------------------
olsLinkDownCond NOTIFICATION-TYPE
OBJECTS { pvxL2IntfSwitchIdx,
pvxL2IntfShelfIdx,
pvxL2IntfSlotIdx,
pvxL2IntfPortTypeIdx,
pvxL2IntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "PVX L2 port link down."
::= { pvxL2PortCondNotifications 0 1 }
olsLinkDownClear NOTIFICATION-TYPE
OBJECTS { pvxL2IntfSwitchIdx,
pvxL2IntfShelfIdx,
pvxL2IntfSlotIdx,
pvxL2IntfPortTypeIdx,
pvxL2IntfPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "PVX L2 port link down has cleared."
::= { pvxL2PortCondNotifications 0 2 }
--------------------------------------
-- ODU-N alarms
--------------------------------------
odunPayloadMismatchCond NOTIFICATION-TYPE
OBJECTS { odunTypeIdx,
odunShelfIdx,
odunSlotIdx,
odunPortIdx,
odunIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A payload mismatch is active on the ODU-N facility."
::= { odunCondNotifications 0 1 }
odunPayloadMismatchClear NOTIFICATION-TYPE
OBJECTS { odunTypeIdx,
odunShelfIdx,
odunSlotIdx,
odunPortIdx,
odunIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active ODU-N facility payload mismatch condition
has cleared."
::= { odunCondNotifications 0 2 }
odunOpenConnectionIndicatorCond NOTIFICATION-TYPE
OBJECTS { odunTypeIdx,
odunShelfIdx,
odunSlotIdx,
odunPortIdx,
odunIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "An OCI is active on the ODU-N facility."
::= { odunCondNotifications 0 3 }
odunOpenConnectionIndicatorClear NOTIFICATION-TYPE
OBJECTS { odunTypeIdx,
odunShelfIdx,
odunSlotIdx,
odunPortIdx,
odunIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active ODU-N OCI condition has cleared."
::= { odunCondNotifications 0 4 }
--------------------------------------
-- BRI alarms
--------------------------------------
briLossOfSignalCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This notification indicates that there is no input signal
detected on the BRI port."
::= { briCondNotifications 0 1 }
briLossOfSignalClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This notification indicates that a previously active BRI Loss
of Signal condition has been cleared."
::= { briCondNotifications 0 2 }
briXcvrMismatchCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "There is a mismatch between the SFP or XFP transceiver
provisioned for the BRI facility port and the
physical transceiver that is inserted in the port. The SFP or
XFP transceiver in the port must match the attributes
provisioned for the BRI facility."
::= { briCondNotifications 0 3 }
briXcvrMismatchClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active BRI XCVR Mistmatch condition has cleared."
::= { briCondNotifications 0 4 }
briOpticalPwrReceivedMinCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
briOpticalPwrReceived,
briOpticalPwrReceivedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the input power for the BRI facility
has fallen below the minimum threshold."
::= { briCondNotifications 0 5 }
briOpticalPwrReceivedMinClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active BRI minimum power recieved condition has
cleared."
::= { briCondNotifications 0 6 }
briOpticalPwrReceivedMaxCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
briOpticalPwrReceived,
briOpticalPwrReceivedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the input power for the BRI facility
has risen above the maximum threshold."
::= { briCondNotifications 0 7 }
briOpticalPwrReceivedMaxClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active BRI maximum power recieved condition has
cleared."
::= { briCondNotifications 0 8 }
briOpticalPwrTransmittedMinCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
briOpticalPwrTransmitted,
briOpticalPwrTransmittedMinTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the output power for the BRI facility
has fallen below the minimum threshold."
::= { briCondNotifications 0 9 }
briOpticalPwrTransmittedMinClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active BRI minimum power transmitted condition has
cleared."
::= { briCondNotifications 0 10 }
briOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
briOpticalPwrTransmitted,
briOpticalPwrTransmittedMaxTh,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the output power for the BRI facility
has risen above the maximum threshold."
::= { briCondNotifications 0 11 }
briOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active BRI maximum power transmitted condition has
cleared."
::= { briCondNotifications 0 12 }
briLossOfMultiframeCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Loss of Multiframe condition is active against the VCG that
is mapped to the identified BRI port."
::= { briCondNotifications 0 13 }
briLossOfMultiframeClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously raised BRI Loss of Multiframe condition has
cleared."
::= { briCondNotifications 0 14 }
briLossOfSequenceCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Loss of Sequence condition is active against the VCG that is
mapped to the identified BRI port."
::= { briCondNotifications 0 15 }
briLossOfSequenceClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active BRI Loss of Sequence condition has
cleared."
::= { briCondNotifications 0 16 }
briLossOfAlignmentCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A Loss of Alignment condition is active against the VCG that
is mapped to the identified BRI port."
::= { briCondNotifications 0 17 }
briLossOfAlignmentClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active BRI Loss of Alignment condition has
cleared."
::= { briCondNotifications 0 18 }
briLoopbackCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that the BRI facility has been provisioned
to enter loopback mode."
::= { briCondNotifications 0 19 }
briLoopbackClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active BRI Loopback condition has cleared."
::= { briCondNotifications 0 20 }
briBandwidthMismatchCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A BRI bandwidth mismatch condition is active on the
port."
::= { briCondNotifications 0 21 }
briBandwidthMismatchClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active BRI bandwidth mismatch condition
has cleared."
::= { briCondNotifications 0 22 }
briLossOfLockCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that a BRI port is unable to lock
on the incoming bit stream. This is a result of either: the
provisioned protocol does not match the incoming signal, or
the incoming signal is excessively degraded."
::= { briCondNotifications 0 23 }
briLossOfLockClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active BRI loss of lock condition
has cleared."
::= { briCondNotifications 0 24 }
briTxLockingCond NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that a BRI client port is in the
process of locking on the signal in the transmit direction."
::= { briCondNotifications 0 25 }
briTxLockingClear NOTIFICATION-TYPE
OBJECTS { briShelfIdx,
briSlotIdx,
briPortIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active BRI TX locking condition has cleared."
::= { briCondNotifications 0 26 }
--------------------------------------
-- NTP assoc alarms
--------------------------------------
ntpAssocSrvrNotReachableCond NOTIFICATION-TYPE
OBJECTS { ntpClientAssocIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that an NTP server can not be reached.
This is a result of either: an invalid IP address, network
problems or the server is down."
::= { ntpcCondNotifications 0 1 }
ntpAssocSrvrNotReachableClear NOTIFICATION-TYPE
OBJECTS { ntpClientAssocIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active NTP server not reachable condition
has cleared."
::= { ntpcCondNotifications 0 2 }
ntpAssocSrvrNotRespondingCond NOTIFICATION-TYPE
OBJECTS { ntpClientAssocIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that an NTP server is reachable but
is not responding to the NTP requests correctly. This can
be a result of either: the server does not have the service
running or there is a server is having problems."
::= { ntpcCondNotifications 0 3 }
ntpAssocSrvrNotRespondingClear NOTIFICATION-TYPE
OBJECTS { ntpClientAssocIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active NTP server not responding condition
has cleared."
::= { ntpcCondNotifications 0 4 }
ntpAssocAuthenFailedCond NOTIFICATION-TYPE
OBJECTS { ntpClientAssocIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "This alarm indicates that NTP authentication has failed.
This can be a result of either: the key is configured
incorrectly on the client side or the NTP server does not
accept the key."
::= { ntpcCondNotifications 0 5 }
ntpAssocAuthenFailedClear NOTIFICATION-TYPE
OBJECTS { ntpClientAssocIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active NTP authentication failed condition
has cleared."
::= { ntpcCondNotifications 0 6 }
ntpTimeAndDateUpdateEvt NOTIFICATION-TYPE
OBJECTS { ntpOldTimeAndDate,
ntpNewTimeAndDate,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This event occurs when the NTP client updates the system date and time
based on a selected reference clocks source."
::= { ntpcEvtNotifications 0 1 }
ntpTimingRefUpdateEvt NOTIFICATION-TYPE
OBJECTS { ntpRefIP,
ntpRefStratum,
evtDateAndTime,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This event occurs when the NTP client has selected a reference clock
source from a list provided. This is the NTP association list."
::= { ntpcEvtNotifications 0 2 }
--------------------------------------
-- Environmental alarms
--------------------------------------
envAttrUnsupportedCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental alarm detection is
configured against a housekeeping input port which is
located on equipment which does not support the configured
function."
::= { envCondNotifications 0 1 }
envAttrUnsupportedClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental attribute unsupported alarm has cleared."
::= { envCondNotifications 0 2 }
envAirComprCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental air compressor failure
alarm is raised."
::= { envCondNotifications 0 3 }
envAirComprClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental air compressor failure
alarm has cleared."
::= { envCondNotifications 0 4 }
envAirCondCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental air conditioning failure
alarm is raised."
::= { envCondNotifications 0 5 }
envAirCondClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental air conditioning failure
alarm has cleared."
::= { envCondNotifications 0 6 }
envAirDryrCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental air dryer failure
alarm is raised."
::= { envCondNotifications 0 7 }
envAirDryrClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental air dryer failure
alarm has cleared."
::= { envCondNotifications 0 8 }
envBatDschrdCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental battery discharging
alarm is raised."
::= { envCondNotifications 0 9 }
envBatDschrdClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental battery discharging
alarm has cleared."
::= { envCondNotifications 0 10 }
envBatteryCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental battery failure
alarm is raised."
::= { envCondNotifications 0 11 }
envBatteryClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental battery failure
alarm has cleared."
::= { envCondNotifications 0 12 }
envClFanCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental cooling fan failure
alarm is raised."
::= { envCondNotifications 0 13 }
envClFanClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental cooling fan failure
alarm has cleared."
::= { envCondNotifications 0 14 }
envCpMajorCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental centralized power major
alarm is raised."
::= { envCondNotifications 0 15 }
envCpMajorClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental centralized power major
alarm has cleared."
::= { envCondNotifications 0 16 }
envCpMinorCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental centralized power minor
alarm is raised."
::= { envCondNotifications 0 17 }
envCpMinorClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental centralized power minor
alarm has cleared."
::= { envCondNotifications 0 18 }
envDoorOpenCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental door open
alarm is raised."
::= { envCondNotifications 0 19 }
envDoorOpenClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental door open
alarm has cleared."
::= { envCondNotifications 0 20 }
envEngineCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental engine failure
alarm is raised."
::= { envCondNotifications 0 21 }
envEngineClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental engine failure
alarm has cleared."
::= { envCondNotifications 0 22 }
envEngOprgCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental engine operating
alarm is raised."
::= { envCondNotifications 0 23 }
envEngOprgClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental engine operating
alarm has cleared."
::= { envCondNotifications 0 24 }
envExplGsCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental explosive gas
alarm is raised."
::= { envCondNotifications 0 25 }
envExplGsClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental explosive gas
alarm has cleared."
::= { envCondNotifications 0 26 }
envFirDetrCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental fire detector failure
alarm is raised."
::= { envCondNotifications 0 27 }
envFirDetrClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental fire detector failure
alarm has cleared."
::= { envCondNotifications 0 28 }
envFireCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental fire
alarm is raised."
::= { envCondNotifications 0 29 }
envFireClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental fire
alarm has cleared."
::= { envCondNotifications 0 30 }
envFloodCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental flood
alarm is raised."
::= { envCondNotifications 0 31 }
envFloodClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental flood
alarm has cleared."
::= { envCondNotifications 0 32 }
envFuseCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental fuse
alarm is raised."
::= { envCondNotifications 0 33 }
envFuseClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental fuse
alarm has cleared."
::= { envCondNotifications 0 34 }
envGenCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental generator failure
alarm is raised."
::= { envCondNotifications 0 35 }
envGenClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental generator failure
alarm has cleared."
::= { envCondNotifications 0 36 }
envGenericCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental generic
alarm is raised."
::= { envCondNotifications 0 37 }
envGenericClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental generic
alarm has cleared."
::= { envCondNotifications 0 38 }
envHiAirCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental high airflow
alarm is raised."
::= { envCondNotifications 0 39 }
envHiAirClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental high airflow
alarm has cleared."
::= { envCondNotifications 0 40 }
envHiHumCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental high humidity
alarm is raised."
::= { envCondNotifications 0 41 }
envHiHumClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental high humidity
alarm has cleared."
::= { envCondNotifications 0 42 }
envHiTempCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental high temperature
alarm is raised."
::= { envCondNotifications 0 43 }
envHiTempClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental high temperature
alarm has cleared."
::= { envCondNotifications 0 44 }
envHiWindCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental high wind
alarm is raised."
::= { envCondNotifications 0 45 }
envHiWindClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental high wind
alarm has cleared."
::= { envCondNotifications 0 46 }
envHiWtrCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental high water
alarm is raised."
::= { envCondNotifications 0 47 }
envHiWtrClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental high water
alarm has cleared."
::= { envCondNotifications 0 48 }
envIceBuildupCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental ice buildup
alarm is raised."
::= { envCondNotifications 0 49 }
envIceBuildupClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental ice buildup
alarm has cleared."
::= { envCondNotifications 0 50 }
envIntruderCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental intrusion
alarm is raised."
::= { envCondNotifications 0 51 }
envIntruderClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental intrusion
alarm has cleared."
::= { envCondNotifications 0 52 }
envLwBatvgCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental low battery voltage
alarm is raised."
::= { envCondNotifications 0 53 }
envLwBatvgClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental low battery voltage
alarm has cleared."
::= { envCondNotifications 0 54 }
envLwFuelCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental low fuel
alarm is raised."
::= { envCondNotifications 0 55 }
envLwFuelClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental low fuel
alarm has cleared."
::= { envCondNotifications 0 56 }
envLwHumCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental low humidity
alarm is raised."
::= { envCondNotifications 0 57 }
envLwHumClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental low humidity
alarm has cleared."
::= { envCondNotifications 0 58 }
envLwPresCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental low cable pressure
alarm is raised."
::= { envCondNotifications 0 59 }
envLwPresClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental low cable pressure
alarm has cleared."
::= { envCondNotifications 0 60 }
envLwTempCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental low temperature
alarm is raised."
::= { envCondNotifications 0 61 }
envLwTempClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental low temperature
alarm has cleared."
::= { envCondNotifications 0 62 }
envLwWtrCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental low water
alarm is raised."
::= { envCondNotifications 0 63 }
envLwWtrClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental low water
alarm has cleared."
::= { envCondNotifications 0 64 }
envMiscCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental miscellaneous
alarm is raised."
::= { envCondNotifications 0 65 }
envMiscClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental miscellaneous
alarm has cleared."
::= { envCondNotifications 0 66 }
envOpenDrCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental open door
alarm is raised."
::= { envCondNotifications 0 67 }
envOpenDrClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental open door
alarm has cleared."
::= { envCondNotifications 0 68 }
envPowerCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental power failure
alarm is raised."
::= { envCondNotifications 0 69 }
envPowerClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental power failure
alarm has cleared."
::= { envCondNotifications 0 70 }
envPumpCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental pump failure
alarm is raised."
::= { envCondNotifications 0 71 }
envPumpClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental pump failure
alarm has cleared."
::= { envCondNotifications 0 72 }
envRectCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental rectifier failure
alarm is raised."
::= { envCondNotifications 0 73 }
envRectClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental rectifier failure
alarm has cleared."
::= { envCondNotifications 0 74 }
envRectHiCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental rectifier high voltage
alarm is raised."
::= { envCondNotifications 0 75 }
envRectHiClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental rectifier high voltage
alarm has cleared."
::= { envCondNotifications 0 76 }
envRectLoCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental rectifier low voltage
alarm is raised."
::= { envCondNotifications 0 77 }
envRectLoClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental rectifier low voltage
alarm has cleared."
::= { envCondNotifications 0 78 }
envSmokeCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental smoke
alarm is raised."
::= { envCondNotifications 0 79 }
envSmokeClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental smoke
alarm has cleared."
::= { envCondNotifications 0 80 }
envToxicGasCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental toxic gas
alarm is raised."
::= { envCondNotifications 0 81 }
envToxicGasClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental toxic gas
alarm has cleared."
::= { envCondNotifications 0 82 }
envVentnCond NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "Indicates that an environmental ventilation system failure
alarm is raised."
::= { envCondNotifications 0 83 }
envVentnClear NOTIFICATION-TYPE
OBJECTS { envCondAttrHKIIdx,
condReportType,
condDateAndTime,
condSeverity,
condServiceAffecting,
trapSeqNum,
condDescription,
condObjectType,
condCodeType }
STATUS current
DESCRIPTION "A previously active environmental ventilation system failure
alarm has cleared."
::= { envCondNotifications 0 84 }
-----------------------------------------------------------------------
-- Database Change Notifications
--
-- When a provisioning or database change is made on the system, a database change
-- trap is sent, signifying that an update has been made to the persisted database on
-- the system.
--
-- A listing of database change notifications is contained in the
-- following table.
-----------------------------------------------------------------------
dbChangeEvt NOTIFICATION-TYPE
OBJECTS { dbChangeDateAndTime,
dbChangeSeqNum,
dbChangeOID,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This message indicates that a change has been made in the
value of the provisioned object identified by the dbChangeOID
Var-Bind. If multiple objects have been changed in the same
transaction, there will be multiple occurrances of the
dbChangeOID object listed in the Var-Bind list."
::= { dbChangeNotifications 0 2 }
dbChangeSecuEvt NOTIFICATION-TYPE
OBJECTS { dbChangeDateAndTime,
dbChangeSeqNum,
trapSeqNum,
evtDescription,
evtObjectType,
evtCodeType }
STATUS current
DESCRIPTION "This message indicates that a change has been made in the
value of the SNMP community string, SNMP trap reciever, or
Tl1User."
::= { dbChangeNotifications 0 3 }
-----------------------------------------------------------------------
-- LLDP Events
-----------------------------------------------------------------------
pvxLldpRemTablesChangeEvt NOTIFICATION-TYPE
OBJECTS {
pvxL2IntfSwitchIdx }
STATUS current
DESCRIPTION "A pvxLldpRemTablesChangeEvt notification is sent when the value
of pvxLldpStatsRemTablesLastChangeTime changes. It can be
utilized by an NMS to trigger LLDP remote systems table
maintenance polls. Note that transmission of lldpRemTablesChange
notifications are throttled by the agent.
The agent must not generate more than one lldpRemTablesChange
notification-event in the indicated period, where a
'notification-event' is the transmission of a single
notification PDU type to a list of notification destinations.
If additional changes in lldpRemoteSystemsData object
groups occur within the indicated throttling period,
then these trap- events must be suppressed by the
agent.
By default the throttling period is set to 10 seconds."
::= { pvxLldpEvtNotifications 0 1 }
END -- End of BTI-7000-MIB Module, must a /NL character at the end this line!