-- Copyright (c) 2002-2011 Broadcom Corporation
|
|
--
|
|
-- This program is the proprietary software of Broadcom Corporation and/or
|
|
-- its licensors, and may only be used, duplicated, modified or distributed
|
|
-- pursuant to the terms and conditions of a separate, written license
|
|
-- agreement executed between you and Broadcom (an "Authorized License").
|
|
-- Except as set forth in an Authorized License, Broadcom grants no license
|
|
-- (express or implied), right to use, or waiver of any kind with respect to
|
|
-- the Software, and Broadcom expressly reserves all rights in and to the
|
|
-- Software and all intellectual property rights therein. IF YOU HAVE NO
|
|
-- AUTHORIZED LICENSE, THEN YOU HAVE NO RIGHT TO USE THIS SOFTWARE IN ANY WAY,
|
|
-- AND SHOULD IMMEDIATELY NOTIFY BROADCOM AND DISCONTINUE ALL USE OF THE
|
|
-- SOFTWARE.
|
|
--
|
|
-- Except as expressly set forth in the Authorized License,
|
|
--
|
|
-- 1. This program, including its structure, sequence and organization,
|
|
-- constitutes the valuable trade secrets of Broadcom, and you shall use all
|
|
-- reasonable efforts to protect the confidentiality thereof, and to use this
|
|
-- information only in connection with your use of Broadcom integrated circuit
|
|
-- products.
|
|
--
|
|
-- 2. TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE SOFTWARE IS PROVIDED
|
|
-- "AS IS" AND WITH ALL FAULTS AND BROADCOM MAKES NO PROMISES, REPRESENTATIONS
|
|
-- OR WARRANTIES, EITHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, WITH
|
|
-- RESPECT TO THE SOFTWARE. BROADCOM SPECIFICALLY DISCLAIMS ANY AND ALL
|
|
-- IMPLIED WARRANTIES OF TITLE, MERCHANTABILITY, NONINFRINGEMENT, FITNESS FOR
|
|
-- A PARTICULAR PURPOSE, LACK OF VIRUSES, ACCURACY OR COMPLETENESS, QUIET
|
|
-- ENJOYMENT, QUIET POSSESSION OR CORRESPONDENCE TO DESCRIPTION. YOU ASSUME
|
|
-- THE ENTIRE RISK ARISING OUT OF USE OR PERFORMANCE OF THE SOFTWARE.
|
|
--
|
|
-- 3. TO THE MAXIMUM EXTENT PERMITTED BY LAW, IN NO EVENT SHALL BROADCOM
|
|
-- OR ITS LICENSORS BE LIABLE FOR (i) CONSEQUENTIAL, INCIDENTAL, SPECIAL,
|
|
-- INDIRECT, OR EXEMPLARY DAMAGES WHATSOEVER ARISING OUT OF OR IN ANY WAY
|
|
-- RELATING TO YOUR USE OF OR INABILITY TO USE THE SOFTWARE EVEN IF BROADCOM
|
|
-- HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES; OR (ii) ANY AMOUNT IN
|
|
-- EXCESS OF THE AMOUNT ACTUALLY PAID FOR THE SOFTWARE ITSELF OR U.S. $1,
|
|
-- WHICHEVER IS GREATER. THESE LIMITATIONS SHALL APPLY NOTWITHSTANDING ANY
|
|
-- FAILURE OF ESSENTIAL PURPOSE OF ANY LIMITED REMEDY.
|
|
--
|
|
--****************************************************************************
|
|
-- Filename: brcm-cm-engineering.mib
|
|
-- Author: Kevin O'Neal
|
|
-- Creation Date: 22-october-2002
|
|
--
|
|
--****************************************************************************
|
|
-- Description:
|
|
--
|
|
-- private MIB for cablemodem factory
|
|
--
|
|
--****************************************************************************
|
|
-- Revision History:
|
|
--
|
|
--****************************************************************************
|
|
|
|
BRCM-CM-ENGINEERING-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Integer32,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
TruthValue, RowPointer
|
|
FROM SNMPv2-TC
|
|
TenthdBmV,
|
|
TenthdB
|
|
FROM DOCS-IF-MIB
|
|
cableDataEngineering
|
|
FROM BRCM-CABLEDATA-ENGINEERING-MIB
|
|
cmDsCalOffsetIndex
|
|
FROM BRCM-CM-FACTORY-MIB;
|
|
|
|
cablemodemEngineering MODULE-IDENTITY
|
|
LAST-UPDATED "201104140000Z"
|
|
ORGANIZATION "Broadcom Corporation"
|
|
CONTACT-INFO
|
|
" BANANA-CABLEDATA
|
|
(cableData branch of the
|
|
Broadcom Assigned Numbers and Naming Authority)
|
|
Broadcom Corporation
|
|
|
|
Postal: 4385 River Green Parkway
|
|
Duluth, GA 30096
|
|
USA
|
|
|
|
Tel: +1 770 232-0018
|
|
|
|
E-mail: banana-cabledata@broadcom.com"
|
|
DESCRIPTION
|
|
"Broadcom proprietary MIB for management and configuration
|
|
of cablemodem objects used in engineering and development."
|
|
REVISION "201104140000Z"
|
|
DESCRIPTION
|
|
"Added object cmDsCalPhySymbolRate."
|
|
REVISION "201010200000Z"
|
|
DESCRIPTION
|
|
"Updated value ranges on cmDsCalTunerIndex, cmDsCalPhyTuner and
|
|
cmDsCalPhyTunerChannel."
|
|
REVISION "200910060000Z"
|
|
DESCRIPTION
|
|
"Added cmEngrBpi objects.
|
|
Removed DEFVAL from cmDsCalTunerType object to fix compiler warning."
|
|
REVISION "200904030000Z"
|
|
DESCRIPTION
|
|
"Added object cmUsCalDiplexer."
|
|
REVISION "200811030000Z"
|
|
DESCRIPTION
|
|
"Added objects cmDsCalPhyFrequency and cmDsCalPhyFrequencyError."
|
|
REVISION "200809230000Z"
|
|
DESCRIPTION
|
|
"Added cmDsCalTunerTable and cmDsCalPhyTable in support of systems
|
|
which support multiple DS phys per tuner."
|
|
REVISION "200702050000Z"
|
|
DESCRIPTION
|
|
"Module description was updated.
|
|
Compilability issues were cleaned up:
|
|
- Chronological order of revision history was corrected.
|
|
- Revision dates were updated to post-Y2K format.
|
|
- Range restrictions were added to objects cmDsCalTunerCoefIndex,
|
|
cmDsCalIFCoefIndex, cmDsCalFineCoefIndex, cmDsCalEqCoefIndex, and
|
|
cmUsCalControlIndex."
|
|
REVISION "200306230000Z"
|
|
DESCRIPTION
|
|
"Added objects to allow dynamic population and de-population of
|
|
the downstream and upstream calibration tables in order to provide
|
|
more efficient RAM management when performing downstream and
|
|
upstream CM characterization."
|
|
REVISION "200304240000Z"
|
|
DESCRIPTION
|
|
"Added cmDsCalFrequencyError object."
|
|
REVISION "200301030000Z"
|
|
DESCRIPTION
|
|
"Added cmHwSTABW2 object."
|
|
REVISION "200212230000Z"
|
|
DESCRIPTION
|
|
"Added AGC control objects. Ho, Ho, Ho."
|
|
REVISION "200212110000Z"
|
|
DESCRIPTION
|
|
"Added more DS cal objects to control and report the results of the
|
|
CM DS characterization routine."
|
|
REVISION "200211110000Z"
|
|
DESCRIPTION
|
|
"Added objects for 33xx hardware control in cmEngrBase and
|
|
populated cmEngrUpstreamCalibration."
|
|
REVISION "200210220000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { cableDataEngineering 2 }
|
|
|
|
-- cmEngrBase: miscellaneous control/state objects for engineering mode
|
|
cmEngrBase OBJECT IDENTIFIER ::= { cablemodemEngineering 1 }
|
|
|
|
cmEngr33xxOpcode OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hardware address or multibyte opcode to access in a 33xx family
|
|
device when executing a cmEngr33xxCommand operation."
|
|
::= { cmEngrBase 1 }
|
|
|
|
cmEngr33xxData OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The data read from or to be written to a 33xx family device when
|
|
executing a cmEngr33xxCommand operation."
|
|
::= { cmEngrBase 2 }
|
|
|
|
cmEngr33xxCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
read(0),
|
|
write(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this value to read(0) will cause a read operation to be
|
|
executed on the multibyte opcode specified in cmEngr33xxOpcode. The
|
|
data read back from the operation will be presented in cmEngr33xxData.
|
|
Setting this value to write(1) will cause the data in cmEngr33xxData
|
|
to be written via the multibyte opcode specified in cmEngr33xxOpcode."
|
|
::= { cmEngrBase 3 }
|
|
|
|
-- cmEngrDownstreamCalibration: used to characterize a family of devices,
|
|
-- typically not necessary for manufacturing of individual units.
|
|
cmEngrDownstreamCalibration OBJECT IDENTIFIER ::= { cablemodemEngineering 2 }
|
|
|
|
--
|
|
-- Tuner Coeficient objects
|
|
--
|
|
|
|
cmDsCalZeroTunerCoefs OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to true(1) will result in all writable objects in
|
|
the cmDsCalTunerCoefTable being set to zero. Sets to false(2) will be
|
|
accepted, but will not result in any action being taken. Reading
|
|
this object always returns false(2)."
|
|
::= { cmEngrDownstreamCalibration 1 }
|
|
|
|
cmDsCalNumTunerCoefs OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the number of tuner coefficients per downstream
|
|
frequency in the cmDsCalTunerCoefTable. Note that the total number
|
|
of entries in this table will be the value of cmDsCalNumOffsets
|
|
(from the BRCM-CM-FACTORY-MIB) multiplied by this value. If this value
|
|
is changed, then the cmDsCalTunerCoefTable will be destroyed and
|
|
rebuilt with the new number of coefficients, but all coefficient values
|
|
will be set to zero."
|
|
::= { cmEngrDownstreamCalibration 2 }
|
|
|
|
cmDsCalTunerCoefTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmDsCalTunerCoefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of tuner coeffiencents to be used when calculating downstream
|
|
power for this device."
|
|
::= { cmEngrDownstreamCalibration 3 }
|
|
|
|
cmDsCalTunerCoefEntry OBJECT-TYPE
|
|
SYNTAX CmDsCalTunerCoefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry defining a tuner coefficient for a given frequency at the
|
|
given index for this device."
|
|
INDEX { cmDsCalOffsetIndex, cmDsCalTunerCoefIndex }
|
|
::= { cmDsCalTunerCoefTable 1 }
|
|
|
|
CmDsCalTunerCoefEntry ::=
|
|
SEQUENCE {
|
|
cmDsCalTunerCoefIndex Integer32,
|
|
cmDsCalTunerCoefFrequency Integer32,
|
|
cmDsCalTunerCoefValue Unsigned32,
|
|
cmDsCalTunerCoefCopyFrom Integer32
|
|
}
|
|
|
|
cmDsCalTunerCoefIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..128)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the instance of this tuner coefficient."
|
|
::= { cmDsCalTunerCoefEntry 1 }
|
|
|
|
cmDsCalTunerCoefFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The downstream frequency at which this instance of
|
|
cmDsCalTunerCoefValue applies. This read-only object is provided here
|
|
for convenience. Value is identical to the value of the read-write
|
|
object cmDsCalOffsetFrequency which may be changed in engineering
|
|
mode if necessary. Changes made to cmDsCalOffsetFrequency will be
|
|
reflected here immediately."
|
|
REFERENCE
|
|
"docsIfDownChannelFrequency from DOCS-IF-MIB"
|
|
::= { cmDsCalTunerCoefEntry 2 }
|
|
|
|
cmDsCalTunerCoefValue OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1000000)
|
|
UNITS "millionth"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this tuner coefficient multiplied by one million.
|
|
For example, a tuner coefficient value of 0.218369 would be
|
|
represented as 218369. This gives a Since tuner coefficients must
|
|
range in value between zero and one, this object will always have a
|
|
value of between zero (0.000000) and one million (1.000000).
|
|
Precision is 1e-6."
|
|
::= { cmDsCalTunerCoefEntry 3 }
|
|
|
|
cmDsCalTunerCoefCopyFrom OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to the value of the first element of an index of
|
|
a row in this table will cause all coefficients for this frequency to
|
|
be copied from the corresponding location in the frequency pointed to
|
|
by the index specified. For example, if cmDsCalTunerCoefCopyFrom.1.1
|
|
is set to 2, then cmDsCalTunerCoefValue.1.1 through
|
|
cmDsCalTunerCoefCopyFrom.1.n will be copied from
|
|
cmDsCalTunerCoefCopyFrom.2.1 through cmDsCalTunerCoefCopyFrom.2.n.
|
|
Reading this object will always return 0."
|
|
::= { cmDsCalTunerCoefEntry 4 }
|
|
|
|
--
|
|
-- IF (Intermediate Frequency) Coeficient objects
|
|
--
|
|
|
|
cmDsCalZeroIFCoefs OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to true(1) will result in all writable objects in
|
|
the cmDsCalIFCoefTable being set to zero. Sets to false(2) will be
|
|
accepted, but will not result in any action being taken. Reading
|
|
this object always returns false(2)."
|
|
::= { cmEngrDownstreamCalibration 4 }
|
|
|
|
cmDsCalNumIFCoefs OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the number of IF coefficients per downstream
|
|
frequency in the cmDsCalIFCoefTable. Note that the total number
|
|
of entries in this table will be the value of cmDsCalNumOffsets
|
|
(from the BRCM-CM-FACTORY-MIB) multiplied by this value. If this value
|
|
is changed, then the cmDsCalIFCoefTable will be destroyed and
|
|
rebuilt with the new number of coefficients, but all coefficient values
|
|
will be set to zero."
|
|
::= { cmEngrDownstreamCalibration 5 }
|
|
|
|
cmDsCalIFCoefTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmDsCalIFCoefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of intermediate frequency coeffiencents to be used when
|
|
calculating downstream power for this device."
|
|
::= { cmEngrDownstreamCalibration 6 }
|
|
|
|
cmDsCalIFCoefEntry OBJECT-TYPE
|
|
SYNTAX CmDsCalIFCoefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry defining an IF coefficient for a given frequency at the
|
|
given index for this device."
|
|
INDEX { cmDsCalOffsetIndex, cmDsCalIFCoefIndex }
|
|
::= { cmDsCalIFCoefTable 1 }
|
|
|
|
CmDsCalIFCoefEntry ::=
|
|
SEQUENCE {
|
|
cmDsCalIFCoefIndex Integer32,
|
|
cmDsCalIFCoefFrequency Integer32,
|
|
cmDsCalIFCoefValue Integer32,
|
|
cmDsCalIFCoefCopyFrom Integer32
|
|
}
|
|
|
|
cmDsCalIFCoefIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..128)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the instance of this IF coefficient."
|
|
::= { cmDsCalIFCoefEntry 1 }
|
|
|
|
cmDsCalIFCoefFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The downstream frequency at which this instance of
|
|
cmDsCalIFCoefValue applies. This read-only object is provided here
|
|
for convenience. Value is identical to the value of the read-write
|
|
object cmDsCalOffsetFrequency which may be changed in engineering
|
|
mode if necessary. Changes made to cmDsCalOffsetFrequency will be
|
|
reflected here immediately."
|
|
REFERENCE
|
|
"docsIfDownChannelFrequency from DOCS-IF-MIB"
|
|
::= { cmDsCalIFCoefEntry 2 }
|
|
|
|
cmDsCalIFCoefValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "hundred-thousandth"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this IF coefficient multiplied by one hundred thousand.
|
|
For example, an IF coefficent value of -2662.94 would be represented
|
|
as -266294000. This gives an effective range of IF coefficent values
|
|
ranging from -21474.83647 to 21474.83647 and a precision of 1e-5"
|
|
::= { cmDsCalIFCoefEntry 3 }
|
|
|
|
cmDsCalIFCoefCopyFrom OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to the value of the first element of an index of
|
|
a row in this table will cause all coefficients for this frequency to
|
|
be copied from the corresponding location in the frequency pointed to
|
|
by the index specified. For example, if cmDsCalIFCoefCopyFrom.1.1
|
|
is set to 2, then cmDsCalIFCoefValue.1.1 through
|
|
cmDsCalIFCoefCopyFrom.1.n will be copied from
|
|
cmDsCalIFCoefCopyFrom.2.1 through cmDsCalIFCoefCopyFrom.2.n.
|
|
Reading this object will always return 0."
|
|
::= { cmDsCalIFCoefEntry 4 }
|
|
|
|
--
|
|
-- Fine Coeficient objects
|
|
--
|
|
|
|
cmDsCalZeroFineCoefs OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to true(1) will result in all writable objects in
|
|
the cmDsCalFineCoefTable being set to zero. Sets to false(2) will be
|
|
accepted, but will not result in any action being taken. Reading
|
|
this object always returns false(2)."
|
|
::= { cmEngrDownstreamCalibration 7 }
|
|
|
|
cmDsCalNumFineCoefs OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the number of Fine coefficients per downstream
|
|
frequency in the cmDsCalFineCoefTable. Note that the total number
|
|
of entries in this table will be the value of cmDsCalNumOffsets
|
|
(from the BRCM-CM-FACTORY-MIB) multiplied by this value. If this value
|
|
is changed, then the cmDsCalFineCoefTable will be destroyed and
|
|
rebuilt with the new number of coefficients, but all coefficient values
|
|
will be set to zero."
|
|
::= { cmEngrDownstreamCalibration 8 }
|
|
|
|
cmDsCalFineCoefTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmDsCalFineCoefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of Fine coeffiencents to be used when calculating downstream
|
|
power for this device."
|
|
::= { cmEngrDownstreamCalibration 9 }
|
|
|
|
cmDsCalFineCoefEntry OBJECT-TYPE
|
|
SYNTAX CmDsCalFineCoefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry defining a Fine coefficient for a given frequency at the
|
|
given index for this device."
|
|
INDEX { cmDsCalOffsetIndex, cmDsCalFineCoefIndex }
|
|
::= { cmDsCalFineCoefTable 1 }
|
|
|
|
CmDsCalFineCoefEntry ::=
|
|
SEQUENCE {
|
|
cmDsCalFineCoefIndex Integer32,
|
|
cmDsCalFineCoefFrequency Integer32,
|
|
cmDsCalFineCoefValue Integer32,
|
|
cmDsCalFineCoefCopyFrom Integer32
|
|
}
|
|
|
|
cmDsCalFineCoefIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..128)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the instance of this Fine coefficient."
|
|
::= { cmDsCalFineCoefEntry 1 }
|
|
|
|
cmDsCalFineCoefFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The downstream frequency at which this instance of
|
|
cmDsCalFineCoefValue applies. This read-only object is provided here
|
|
for convenience. Value is identical to the value of the read-write
|
|
object cmDsCalOffsetFrequency which may be changed in engineering
|
|
mode if necessary. Changes made to cmDsCalOffsetFrequency will be
|
|
reflected here immediately."
|
|
REFERENCE
|
|
"docsIfDownChannelFrequency from DOCS-IF-MIB"
|
|
::= { cmDsCalFineCoefEntry 2 }
|
|
|
|
cmDsCalFineCoefValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "millionth"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this fine coefficient multiplied by one million.
|
|
For example, a fine coefficent value of 36.5494 would be represented
|
|
as 36549400. This gives an effective range of fine coefficent values
|
|
ranging from -2147.483647 to 2147.483647 and a precision of 1e-6."
|
|
::= { cmDsCalFineCoefEntry 3 }
|
|
|
|
cmDsCalFineCoefCopyFrom OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to the value of the first element of an index of
|
|
a row in this table will cause all coefficients for this frequency to
|
|
be copied from the corresponding location in the frequency pointed to
|
|
by the index specified. For example, if cmDsCalFineCoefCopyFrom.1.1
|
|
is set to 2, then cmDsCalFineCoefValue.1.1 through
|
|
cmDsCalFineCoefCopyFrom.1.n will be copied from
|
|
cmDsCalFineCoefCopyFrom.2.1 through cmDsCalFineCoefCopyFrom.2.n.
|
|
Reading this object will always return 0."
|
|
::= { cmDsCalFineCoefEntry 4 }
|
|
|
|
--
|
|
-- Equalizer Coeficient objects
|
|
--
|
|
|
|
cmDsCalZeroEqCoefs OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to true(1) will result in all writable objects in
|
|
the cmDsCalEqualizerCoefTable being set to zero. Sets to false(2) will be
|
|
accepted, but will not result in any action being taken. Reading
|
|
this object always returns false(2)."
|
|
::= { cmEngrDownstreamCalibration 10 }
|
|
|
|
cmDsCalNumEqCoefs OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the number of equalizer coefficients per downstream
|
|
frequency in the cmDsCalEqualizerCoefTable. Note that the total number
|
|
of entries in this table will be the value of cmDsCalNumOffsets
|
|
(from the BRCM-CM-FACTORY-MIB) multiplied by this value. If this value
|
|
is changed, then the cmDsCalEqualizerCoefTable will be destroyed and
|
|
rebuilt with the new number of coefficients, but all coefficient values
|
|
will be set to zero."
|
|
::= { cmEngrDownstreamCalibration 11 }
|
|
|
|
cmDsCalEqCoefTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmDsCalEqCoefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of equalizer coeffiencents to be used when calculating downstream
|
|
power for this device."
|
|
::= { cmEngrDownstreamCalibration 12 }
|
|
|
|
cmDsCalEqCoefEntry OBJECT-TYPE
|
|
SYNTAX CmDsCalEqCoefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry defining a equalizer coefficient for a given frequency at the
|
|
given index for this device."
|
|
INDEX { cmDsCalOffsetIndex, cmDsCalEqCoefIndex }
|
|
::= { cmDsCalEqCoefTable 1 }
|
|
|
|
CmDsCalEqCoefEntry ::=
|
|
SEQUENCE {
|
|
cmDsCalEqCoefIndex Integer32,
|
|
cmDsCalEqCoefFrequency Integer32,
|
|
cmDsCalEqCoefValue Integer32,
|
|
cmDsCalEqCoefCopyFrom Integer32
|
|
}
|
|
|
|
cmDsCalEqCoefIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..128)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the instance of this equalizer coefficient."
|
|
::= { cmDsCalEqCoefEntry 1 }
|
|
|
|
cmDsCalEqCoefFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The downstream frequency at which this instance of
|
|
cmDsCalEqCoefValue applies. This read-only object is provided here
|
|
for convenience. Value is identical to the value of the read-write
|
|
object cmDsCalOffsetFrequency which may be changed in engineering
|
|
mode if necessary. Changes made to cmDsCalOffsetFrequency will be
|
|
reflected here immediately."
|
|
REFERENCE
|
|
"docsIfDownChannelFrequency from DOCS-IF-MIB"
|
|
::= { cmDsCalEqCoefEntry 2 }
|
|
|
|
cmDsCalEqCoefValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "hundred-thousandth"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this equalizer coefficient multiplied by one hundred
|
|
thousand. For example, an equalizer coefficent value of 4287.95 would
|
|
be represented as 428795000. This gives an effective range of
|
|
equalizer coefficent values ranging from -21474.83647 to 21474.83647
|
|
and a precision of 1e-5."
|
|
::= { cmDsCalEqCoefEntry 3 }
|
|
|
|
cmDsCalEqCoefCopyFrom OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to the value of the first element of an index of
|
|
a row in this table will cause all coefficients for this frequency to
|
|
be copied from the corresponding location in the frequency pointed to
|
|
by the index specified. For example, if cmDsCalEqCoefCopyFrom.1.1 is
|
|
set to 2, then cmDsCalEqCoefValue.1.1 through cmDsCalEqCoefCopyFrom.1.n
|
|
will be copied from cmDsCalEqCoefCopyFrom.2.1 through
|
|
cmDsCalEqCoefCopyFrom.2.n. Reading this object will always return 0."
|
|
::= { cmDsCalEqCoefEntry 4 }
|
|
|
|
cmDsCalNumLDAIxReads OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the number of times the LDAIx registers will be read before doing
|
|
the power calculations. It will average the register values."
|
|
::= { cmEngrDownstreamCalibration 13 }
|
|
|
|
cmDsCalLDAIxReadInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the time (in milliseconds) between each read of the LDAIx
|
|
registers."
|
|
::= { cmEngrDownstreamCalibration 14 }
|
|
|
|
cmDsCalTunerStep OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..800)
|
|
UNITS "hundredth dBmV"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the step size (in dBmV) that was used when sampling the tuner
|
|
table. This influences how the data is interpolated when calculating
|
|
the tuner gain part of actual power level."
|
|
::= { cmEngrDownstreamCalibration 15 }
|
|
|
|
cmDsCalMasterPowerOffset OBJECT-TYPE
|
|
SYNTAX Integer32 (-32700..32700)
|
|
UNITS "hundredth dBmV"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the master offset power value (in dBmV) for the modem. Each
|
|
frequency band in the table has an offset power adjustment that is
|
|
applied to this value when calculating the actual power level."
|
|
::= { cmEngrDownstreamCalibration 16 }
|
|
|
|
cmDsCalCharacterizeNow OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set to true(1), the CM will execute its DS characterization
|
|
routine using the frequency specified by cmDsCalFrequency, and the
|
|
modulation type specified by cmDsCalModulation. Prior to executing the
|
|
DS characterization routine, cmDsCalLockNow must have been set to
|
|
true(1) and the lock must have been successful, as indicated by
|
|
cmDsCalQamLocked and cmDsCalFecLocked both being true(1). The SET
|
|
operation will not return until the routine is complete, so the SNMP
|
|
manager's timeout value may need to be increased to several seconds.
|
|
Once the DS characterization is complete, the resulting data may be
|
|
read from the objects cmDsCalNormalLDAIT, cmDsCalNormalLDAIF,
|
|
cmDsCalNormalLDAII, cmDsCalFrozenLDAIT, cmDsCalFrozenLDAIF,
|
|
cmDsCalFrozenLDAII, cmDsCalFGain, cmDsCalTGain, and cmDsCalIGain.
|
|
Always returns false(2) when read."
|
|
::= { cmEngrDownstreamCalibration 17 }
|
|
|
|
cmDsCalNormalLDAIT OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the contents of the LDAIT register after executing the 'normal'
|
|
portion of the CM DS characterization routine."
|
|
::= { cmEngrDownstreamCalibration 18 }
|
|
|
|
cmDsCalNormalLDAIF OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the contents of the LDAIF register after executing the 'normal'
|
|
portion of the CM DS characterization routine."
|
|
::= { cmEngrDownstreamCalibration 19 }
|
|
|
|
cmDsCalNormalLDAII OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the contents of the LDAII register after executing the 'normal'
|
|
portion of the CM DS characterization routine."
|
|
::= { cmEngrDownstreamCalibration 20 }
|
|
|
|
cmDsCalFrozenLDAIT OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the contents of the LDAIT register after executing the 'frozen'
|
|
portion of the CM DS characterization routine."
|
|
::= { cmEngrDownstreamCalibration 21 }
|
|
|
|
cmDsCalFrozenLDAIF OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the contents of the LDAIF register after executing the 'frozen'
|
|
portion of the CM DS characterization routine."
|
|
::= { cmEngrDownstreamCalibration 22 }
|
|
|
|
cmDsCalFrozenLDAII OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the contents of the LDAII register after executing the 'frozen'
|
|
portion of the CM DS characterization routine."
|
|
::= { cmEngrDownstreamCalibration 23 }
|
|
|
|
cmDsCalFGainTap OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the value of the equalizer main tap after executing the F-Gain
|
|
portion of the CM DS characterization routine."
|
|
::= { cmEngrDownstreamCalibration 24 }
|
|
|
|
cmDsCalTGainTap OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the value of the equalizer main tap after executing the T-Gain
|
|
portion of the CM DS characterization routine."
|
|
::= { cmEngrDownstreamCalibration 25 }
|
|
|
|
cmDsCalIGainTap OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the value of the equalizer main tap after executing the I-Gain
|
|
portion of the CM DS characterization routine."
|
|
::= { cmEngrDownstreamCalibration 26 }
|
|
|
|
cmDsCalFrequencyError OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports the amount of frequency error in the downstream signal."
|
|
::= { cmEngrDownstreamCalibration 27 }
|
|
|
|
cmDsCalTunerCoefTablePopulate OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set to true(1), the downstream tuner coefficient data will be
|
|
loaded into the cmDsCalTunerCoefTable. If the table is already
|
|
populated, it will be flushed and re-populated. If the amount of RAM
|
|
available on the device becomes low while populating the table, an
|
|
error code of RESOURCE UNAVAILABLE will be returned, and the table
|
|
population will be incomplete. Setting this object to false(2) will
|
|
flush the cmDsCalTunerCoefTable.
|
|
|
|
When read, this object indicates the current state of the
|
|
cmDsCalTunerCoefTable. A value of true(1) indicates that the table was
|
|
successfully populated. A value of false(2) indicates that the table
|
|
is either unpopulated, or that insufficient RAM was available to
|
|
complete the population and that the table is incomplete."
|
|
::= { cmEngrDownstreamCalibration 28 }
|
|
|
|
cmDsCalIFCoefTablePopulate OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set to true(1), the downstream intermediate frequency coefficient
|
|
data will be loaded into the cmDsCalIFCoefTable. If the table is
|
|
already populated, it will be flushed and re-populated. If the amount
|
|
of RAM available on the device becomes low while populating the table,
|
|
an error code of RESOURCE UNAVAILABLE will be returned, and the table
|
|
population will be incomplete. Setting this object to false(2) will
|
|
flush the cmDsCalIFCoefTable.
|
|
|
|
When read, this object indicates the current state of the
|
|
cmDsCalIFCoefTable. A value of true(1) indicates that the table was
|
|
successfully populated. A value of false(2) indicates that the table
|
|
is either unpopulated, or that insufficient RAM was available to
|
|
complete the population and that the table is incomplete."
|
|
::= { cmEngrDownstreamCalibration 29 }
|
|
|
|
cmDsCalFineCoefTablePopulate OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set to true(1), the downstream fine coefficient data will be
|
|
loaded into the cmDsCalFineCoefTable. If the table is already
|
|
populated, it will be flushed and re-populated. If the amount of RAM
|
|
available on the device becomes low while populating the table, an
|
|
error code of RESOURCE UNAVAILABLE will be returned, and the table
|
|
population will be incomplete. Setting this object to false(2) will
|
|
flush the cmDsCalFineCoefTable.
|
|
|
|
When read, this object indicates the current state of the
|
|
cmDsCalFineCoefTable. A value of true(1) indicates that the table was
|
|
successfully populated. A value of false(2) indicates that the table
|
|
is either unpopulated, or that insufficient RAM was available to
|
|
complete the population and that the table is incomplete."
|
|
::= { cmEngrDownstreamCalibration 30 }
|
|
|
|
cmDsCalEqCoefTablePopulate OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set to true(1), the downstream equalizer coefficient data will be
|
|
loaded into the cmDsCalEqCoefTable. If the table is already
|
|
populated, it will be flushed and re-populated. If the amount of RAM
|
|
available on the device becomes low while populating the table, an
|
|
error code of RESOURCE UNAVAILABLE will be returned, and the table
|
|
population will be incomplete. Setting this object to false(2) will
|
|
flush the cmDsCalEqCoefTable.
|
|
|
|
When read, this object indicates the current state of the
|
|
cmDsCalEqCoefTable. A value of true(1) indicates that the table was
|
|
successfully populated. A value of false(2) indicates that the table
|
|
is either unpopulated, or that insufficient RAM was available to
|
|
complete the population and that the table is incomplete."
|
|
::= { cmEngrDownstreamCalibration 31 }
|
|
|
|
cmDsCalTunerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmDsCalTunerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table used to control all tuners present on this device."
|
|
::= { cmEngrDownstreamCalibration 32 }
|
|
|
|
cmDsCalTunerEntry OBJECT-TYPE
|
|
SYNTAX CmDsCalTunerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry used to control an individual tuner."
|
|
INDEX { cmDsCalTunerIndex }
|
|
::= { cmDsCalTunerTable 1 }
|
|
|
|
CmDsCalTunerEntry ::=
|
|
SEQUENCE {
|
|
cmDsCalTunerIndex Integer32,
|
|
cmDsCalTunerType INTEGER,
|
|
cmDsCalTunerNumChannels Integer32,
|
|
cmDsCalTunerFrequency Integer32,
|
|
cmDsCalTunerTuneNow TruthValue
|
|
}
|
|
|
|
cmDsCalTunerIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the instance of this tuner."
|
|
::= { cmDsCalTunerEntry 1 }
|
|
|
|
cmDsCalTunerType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temic473x(1),
|
|
temic4937(2),
|
|
celISG2000(3),
|
|
celISG2000EU(4),
|
|
celISG3300(5),
|
|
celISG3300EU(6),
|
|
celISG3300DS(7),
|
|
celISG3300DSEU(8),
|
|
panasonicET10(9),
|
|
panasonicET03(10),
|
|
alps(11),
|
|
bcm3400(12),
|
|
temic4706(13),
|
|
bcm3415(14), -- not for use in North America
|
|
alpsEU(15),
|
|
philips1236(16),
|
|
vendor(17),
|
|
bcm3416(18),
|
|
bcm3419(19),
|
|
bcm3418(20),
|
|
bcm3420(21),
|
|
bcm3421(22),
|
|
bcm3422(23),
|
|
bcmInternal(24)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the type of this tuner."
|
|
::= { cmDsCalTunerEntry 2 }
|
|
|
|
cmDsCalTunerNumChannels OBJECT-TYPE
|
|
SYNTAX Integer32 (1..5)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the maximum number of downstream channels which may be
|
|
tuned by this tuner in this application. Note that the value of this
|
|
object depends on the annex mode, because in Annex A each channel is
|
|
8MHz in width, whereas in Annex B each channel is 6MHz in width."
|
|
::= { cmDsCalTunerEntry 3 }
|
|
|
|
cmDsCalTunerFrequency OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1000000000)
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The center frequency to which this tuner will tune when
|
|
cmDsCalTunerTuneNow is set to true(1). Note that a read of this object
|
|
does NOT necessarily indicate that the CM is currently tuned to the
|
|
indicated frequency, since the CM will not tune until
|
|
cmDsCalTunerTuneNow is set to true(1)."
|
|
REFERENCE
|
|
"docsIfDownChannelFrequency from DOCS-IF-MIB"
|
|
::= { cmDsCalTunerEntry 4 }
|
|
|
|
cmDsCalTunerTuneNow OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this object is set to true(1), the tuner will tune to the
|
|
frequency specified by cmDsCalTunerFrequency. Sets
|
|
to false(2) will be rejected with an inconsistentValue error.
|
|
taken. When read, this object returns true(1) if the tuner is
|
|
currently tuned to the specified frequency, false(2) otherwise."
|
|
::= { cmDsCalTunerEntry 5 }
|
|
|
|
cmDsCalPhyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmDsCalPhyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table which allows control over each individual downstream phy
|
|
block present on the device."
|
|
::= { cmEngrDownstreamCalibration 33 }
|
|
|
|
cmDsCalPhyEntry OBJECT-TYPE
|
|
SYNTAX CmDsCalPhyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry allowing control over an individual downstream phy block."
|
|
INDEX { cmDsCalPhyIndex }
|
|
::= { cmDsCalPhyTable 1 }
|
|
|
|
CmDsCalPhyEntry ::=
|
|
SEQUENCE {
|
|
cmDsCalPhyIndex Integer32,
|
|
cmDsCalPhyTuner Integer32,
|
|
cmDsCalPhyTunerChannel Integer32,
|
|
cmDsCalPhyModulation INTEGER,
|
|
cmDsCalPhyLockNow TruthValue,
|
|
cmDsCalPhyQamLocked TruthValue,
|
|
cmDsCalPhyFecLocked TruthValue,
|
|
cmDsCalPhySignalNoise TenthdB,
|
|
cmDsCalPhyPower TenthdBmV,
|
|
cmDsCalPhyFrequency Integer32,
|
|
cmDsCalPhyFrequencyError Integer32,
|
|
cmDsCalPhySymbolRate Integer32
|
|
}
|
|
|
|
cmDsCalPhyIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..12)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the instance of this phy block."
|
|
::= { cmDsCalPhyEntry 1 }
|
|
|
|
cmDsCalPhyTuner OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls which tuner from the cmDsCalTunerTable this phy is mapped to."
|
|
::= { cmDsCalPhyEntry 2 }
|
|
|
|
cmDsCalPhyTunerChannel OBJECT-TYPE
|
|
SYNTAX Integer32 (-8..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls which channel of the tuner identified by cmDsCalPhyTuner is
|
|
mapped to this phy. Values are defined as offsets from the center
|
|
channel of the tuner, which is represented by a value of 0 for this
|
|
object. Note that allowable values for this object are constrained
|
|
by the value of cmDsCalTunerNumChannels for the tuner specified by
|
|
cmDsCalPhyTuner. A value of 0 - denoting the exact center channel -
|
|
is only valid if cmDsCalTunerNumChannels is odd. For even values of
|
|
cmDsCalTunerNumChannels, locking to the exact center frequency will
|
|
not be possible."
|
|
::= { cmDsCalPhyEntry 3 }
|
|
|
|
cmDsCalPhyModulation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
qam64(3),
|
|
qam256(4),
|
|
qam1024(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The modulation type that the CM will attempt to lock under
|
|
when cmDsCalPhyLockNow is set to true. Note that a read of
|
|
this object does NOT necessarily indicate that the CM is
|
|
currently locked under the indicated modulation, since the
|
|
CM will not attempt to lock until cmDsCalPhyLockNow is set to
|
|
true. The enumerated values for this object begin at 3 for
|
|
consistency with the docsIfDownChannelModulation values."
|
|
REFERENCE
|
|
"docsIfDownChannelModulation from DOCS-IF-MIB"
|
|
::= { cmDsCalPhyEntry 4 }
|
|
|
|
cmDsCalPhyLockNow OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this object is set to true(1), the CM will attempt to lock the
|
|
downstream phy according to the parameters specified by the values of
|
|
cmDsCalTunerCenterFrequency, cmDsCalPhyTuner, cmDsCalPhyTunerChannel,
|
|
and cmDsCalPhyModulation. Note that prior to setting this object,
|
|
the instance of cmDsCalTunerTuneNow corresponding to the value of
|
|
cmDsCalPhyTuner must have previously been set to true(1). Sets
|
|
of this object to false(2) will be rejected with an inconsistentValue
|
|
error. When read, this object returns false(2) if no lock has been
|
|
attempted, and true(1) if a lock has been attempted. The success
|
|
or failure of an attempted lock is indicated by the values of objects
|
|
cmDsCalPhyQamLocked and cmDsCalPhyFecLocked."
|
|
::= { cmDsCalPhyEntry 5 }
|
|
|
|
cmDsCalPhyQamLocked OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the last set of cmDsCalPhyLockNow to true resulted
|
|
in the phy acheiving QAM lock. The value of this object is reset
|
|
whenever cmDsCalPhyLockNow is set to true, and its value will always
|
|
indicate the result of the last attempt to lock."
|
|
::= { cmDsCalPhyEntry 6 }
|
|
|
|
cmDsCalPhyFecLocked OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the last set of cmDsCalPhyLockNow to true resulted
|
|
in the phy acheiving FEC lock. The value of this object is reset
|
|
whenever cmDsCalPhyLockNow is set to true, and its value will always
|
|
indicate the result of the last attempt to lock."
|
|
::= { cmDsCalPhyEntry 7 }
|
|
|
|
cmDsCalPhySignalNoise OBJECT-TYPE
|
|
SYNTAX TenthdB
|
|
UNITS "TenthdB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signal/Noise ratio as perceived for this phy."
|
|
REFERENCE
|
|
"Data-Over-Cable Service Interface Specifications: Radio
|
|
Frequency Interface Specification SP-RFIv2.0-I10-051209,
|
|
Tables 4-1 and 4-2"
|
|
::= { cmDsCalPhyEntry 8 }
|
|
|
|
cmDsCalPhyPower OBJECT-TYPE
|
|
SYNTAX TenthdBmV
|
|
UNITS "dBmV"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The received power level for this phy."
|
|
REFERENCE
|
|
"Data-Over-Cable Service Interface Specifications: Radio
|
|
Frequency Interface Specification SP-RFIv2.0-I10-051209,
|
|
Tables 6-16, 6-17."
|
|
::= { cmDsCalPhyEntry 9 }
|
|
|
|
cmDsCalPhyFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports the frequency to which this phy is locked. The value of this
|
|
object will reflect the frequency as calculated according to the
|
|
settings of cmDsCalPhyTuner and cmDsCalPhyTuner, and does not include
|
|
the frequency error as reported by cmDsCalPhyFrequencyError. If
|
|
cmDsCalPhyLockNow has not been set to true(1) then this object will
|
|
report a value of 0."
|
|
::= { cmDsCalPhyEntry 10 }
|
|
|
|
cmDsCalPhyFrequencyError OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports the frequency error for this phy. The actual frequency to
|
|
which the phy is locked will be the sum of the value of this object
|
|
and cmDsCalPhyFrequency. If cmDsCalPhyLockNow has not been set to
|
|
true(1) then this object will report a value of 0."
|
|
::= { cmDsCalPhyEntry 11 }
|
|
|
|
cmDsCalPhySymbolRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "symbols per second"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports the downstream symbol rate for this phy. If cmDsCalPhyLockNow
|
|
has not been set to true(1) then this object will report a value of 0."
|
|
::= { cmDsCalPhyEntry 12 }
|
|
|
|
---
|
|
--- Upstream Calibration engineering objects
|
|
---
|
|
|
|
cmEngrUpstreamCalibration OBJECT IDENTIFIER ::= { cablemodemEngineering 3 }
|
|
|
|
cmUsCalControlStartPower OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
UNITS "dBmV"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the starting power used in the
|
|
cmUsCalControlTable. Changing this value will result in the size of
|
|
the cmUsCalControlTable being altered."
|
|
::= { cmEngrUpstreamCalibration 1 }
|
|
|
|
cmUsCalControlEndPower OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
UNITS "dBmV"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the ending power used in the
|
|
cmUsCalControlTable. Changing this value will result in the size of
|
|
the cmUsCalControlTable being altered."
|
|
::= { cmEngrUpstreamCalibration 2 }
|
|
|
|
cmUsCalControlResolution OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
UNITS "hundredth dBmV"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the resolution used in the
|
|
cmUsCalControlTable. Changing this value will result in the size of
|
|
the cmUsCalControlTable being altered."
|
|
::= { cmEngrUpstreamCalibration 3 }
|
|
|
|
cmUsCalZeroControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If set to true(1), all instances of cmUsCalControlAmpGain and
|
|
cmUsCalControlDacAtten in the cmUsCalControlTable will be set to
|
|
a value of zero. When read, always returns false."
|
|
::= { cmEngrUpstreamCalibration 4 }
|
|
|
|
cmUsCalControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmUsCalControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of control values to be used when calculating upstream
|
|
power for this device."
|
|
::= { cmEngrUpstreamCalibration 5 }
|
|
|
|
cmUsCalControlEntry OBJECT-TYPE
|
|
SYNTAX CmUsCalControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry defining the control values for a given power at the given
|
|
index for this device."
|
|
INDEX { cmUsCalControlIndex }
|
|
::= { cmUsCalControlTable 1 }
|
|
|
|
CmUsCalControlEntry ::=
|
|
SEQUENCE {
|
|
cmUsCalControlIndex Integer32,
|
|
cmUsCalControlPower Integer32,
|
|
cmUsCalControlAmpGain Unsigned32,
|
|
cmUsCalControlDacAtten Unsigned32
|
|
}
|
|
|
|
cmUsCalControlIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..128)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the instance of this pair of control values."
|
|
::= { cmUsCalControlEntry 1 }
|
|
|
|
cmUsCalControlPower OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
UNITS "hundredth dBmV"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the upstream power level which is expected when the
|
|
amp gain and DAC attenuation are programmed as indicated in this
|
|
entry. This value is read-only, its value depends on the values
|
|
set in cmUsCalControlStartPower, cmUsCalControlEndPower, and
|
|
cmUsCalControlResolution."
|
|
::= { cmUsCalControlEntry 2 }
|
|
|
|
cmUsCalControlAmpGain OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the amplifier gain setting used to produce
|
|
an output power equal to the value of this entry's instance of
|
|
cmUsCalControlPower."
|
|
::= { cmUsCalControlEntry 3 }
|
|
|
|
cmUsCalControlDacAtten OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the DAC attenuation setting used to produce
|
|
an output power equal to the value of this entry's instance of
|
|
cmUsCalControlPower."
|
|
::= { cmUsCalControlEntry 4 }
|
|
|
|
cmUsCalOffsetStartFreq OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
UNITS "megahertz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the starting frequency used in the
|
|
cmUsCalOffsetTable. Changing this value will result in the size of
|
|
the cmUsCalOffsetTable being altered."
|
|
::= { cmEngrUpstreamCalibration 6 }
|
|
|
|
cmUsCalOffsetEndFreq OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
UNITS "megahertz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the ending frequency used in the
|
|
cmUsCalOffsetTable. Changing this value will result in the size of
|
|
the cmUsCalOffsetTable being altered."
|
|
::= { cmEngrUpstreamCalibration 7 }
|
|
|
|
cmUsCalOffsetResolution OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
UNITS "hundredth megahertz (10 kHz)"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the resolution used in the
|
|
cmUsCalOffsetTable. Changing this value will result in the size of
|
|
the cmUsCalControlTable being altered."
|
|
::= { cmEngrUpstreamCalibration 8 }
|
|
|
|
cmUsCalBoardType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
genericUnknownDontCare(0),
|
|
bcm93350AV2US(1),
|
|
bcm93350AV3US(2),
|
|
bcm93350CV0US(3),
|
|
bcm93350iV1aUS(4),
|
|
bcm93350iV1bUS(5),
|
|
bcm93350VV1US(6),
|
|
bcm93352VV0US(7),
|
|
bcm93350AV2Euro(8),
|
|
bcm93350AV3Euro(9),
|
|
bcm93350CV0Euro(10),
|
|
bcm93350iV1aEuro(11),
|
|
bcm93350iV1bEuro(12),
|
|
bcm93350VV1Euro(13),
|
|
bcm93352VV0Euro(14),
|
|
bcm93350CV2US(15),
|
|
bcm93350CV2Euro(16),
|
|
bcm93345I(17),
|
|
bcm93345A(18)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the board revision that the tables have been calibrated for; it
|
|
helps the app warn the user about incorrect configurations (loading a
|
|
table that has been calibrated for a different modem). These values
|
|
are the same as those found in the HAL non-vol settings."
|
|
DEFVAL { genericUnknownDontCare }
|
|
::= { cmEngrUpstreamCalibration 9 }
|
|
|
|
cmUsCalAmpType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lucentATTV4910(1),
|
|
lucentATTV4911(2),
|
|
celISG2000(3),
|
|
anadigicsARA5050(4),
|
|
adi8321(5),
|
|
maxim3510(6),
|
|
celISG3300(7),
|
|
adi8322(8),
|
|
broadcomInternal(9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the upstream amp that the tables have been calibrated for; it
|
|
helps the app warn the user about incorrect configurations. These
|
|
values are the same as those found in the HAL non-vol settings."
|
|
DEFVAL { broadcomInternal }
|
|
::= { cmEngrUpstreamCalibration 10 }
|
|
|
|
cmUsCalAmpGain OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the current value of the amplifier gain, an 8
|
|
bit hardware value."
|
|
::= { cmEngrUpstreamCalibration 11 }
|
|
|
|
cmUsCalDacAtten OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the current value of the DAC attenuator, an 8
|
|
bit hardware value."
|
|
::= { cmEngrUpstreamCalibration 12 }
|
|
|
|
cmUsCalTransmitNow OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cw(1),
|
|
bits23(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set to cw(1), the device will begin transmitting upstream in
|
|
CW mode using the specified amp gain and DAC attenuation values. When
|
|
set to bits23(2), the device will begin transmitting upstream in 23
|
|
bit mode using the specified amp gain and DAC attenuation values."
|
|
::= { cmEngrUpstreamCalibration 13 }
|
|
|
|
cmUsCalControlTablePopulate OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set to true(1), the upstream calibration control data will be
|
|
loaded into the cmUsCalControlTable. If the table is already
|
|
populated, it will be flushed and re-populated. If the amount of RAM
|
|
available on the device becomes low while populating the table, an
|
|
error code of RESOURCE UNAVAILABLE will be returned, and the table
|
|
population will be incomplete. Setting this object to false(2) will
|
|
flush the cmUsCalControlTable.
|
|
|
|
When read, this object indicates the current state of the
|
|
cmUsCalControlTable. A value of true(1) indicates that the table was
|
|
successfully populated. A value of false(2) indicates that the table
|
|
is either unpopulated, or that insufficient RAM was available to
|
|
complete the population and that the table is incomplete."
|
|
::= { cmEngrUpstreamCalibration 14 }
|
|
|
|
cmUsCalDiplexerType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lowSplit(1),
|
|
midSplit(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the diplexer type on this board. The primary
|
|
effect that this setting has is to control the range of frequencies
|
|
used in upstream calibration when operating in annex B mode. A board
|
|
with a lowSplit diplexer will be calibrated over a frequency range of
|
|
5..42 MHz, while a board with a midSplit diplexer will be calibrated
|
|
over a frequency range of 5..85 MHz. This setting does not affect the
|
|
calibration of an annex A board, which will always have a frequency
|
|
range of 5..65 MHz."
|
|
DEFVAL { lowSplit }
|
|
::= { cmEngrUpstreamCalibration 15 }
|
|
|
|
---
|
|
--- Hardware engineering objects
|
|
---
|
|
|
|
cmEngrHardware OBJECT IDENTIFIER ::= { cablemodemEngineering 4 }
|
|
|
|
cmHwDSAGI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IF AGC Control"
|
|
::= { cmEngrHardware 1 }
|
|
|
|
cmHwDSAGT OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RF (Tuner) AGC Control"
|
|
::= { cmEngrHardware 2 }
|
|
|
|
cmHwSTPGA1 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..16777215)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IF PGA Control"
|
|
::= { cmEngrHardware 3 }
|
|
|
|
cmHwSTABW OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AGC Bandwidth Control"
|
|
::= { cmEngrHardware 4 }
|
|
|
|
cmHwSTABW2 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AGC Bandwidth Control 2"
|
|
::= { cmEngrHardware 5 }
|
|
|
|
---
|
|
--- BPI engineering objects
|
|
---
|
|
|
|
cmEngrBpi OBJECT IDENTIFIER ::= { cablemodemEngineering 5 }
|
|
|
|
cmBpiTekEven OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0 | 8 | 16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the BPI Traffic Encryption Key (TEK) EVEN
|
|
Key. The value may be 8 bytes if DES, 16 bytes if AES, or
|
|
0 bytes (empty string) if not configured."
|
|
::= { cmEngrBpi 1 }
|
|
|
|
cmBpiTekOdd OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0 | 8 | 16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the BPI Traffic Encryption Key (TEK) ODD
|
|
Key. The value may be 8 bytes if DES, 16 bytes if AES, or
|
|
0 bytes (empty string) if not configured."
|
|
::= { cmEngrBpi 2 }
|
|
|
|
cmBpiCbcIvEven OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0 | 8 | 16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the BPI Cipher Block Chaining EVEN
|
|
Initialization Vector. The value may be 8 bytes if DES,
|
|
16 bytes if AES, or 0 bytes (empty string) if not configured."
|
|
::= { cmEngrBpi 3 }
|
|
|
|
cmBpiCbcIvOdd OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0 | 8 | 16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the BPI Cipher Block Chaining ODD
|
|
Initialization Vector. The value may be 8 bytes if DES,
|
|
16 bytes if AES, or 0 bytes (empty string) if not configured."
|
|
::= { cmEngrBpi 4 }
|
|
|
|
END
|