288 lines
10 KiB
Plaintext
288 lines
10 KiB
Plaintext
--****************************************************************************
|
|
--
|
|
-- Copyright (c) 2007-2009 Broadcom Corporation
|
|
--
|
|
-- This program is the proprietary software of Broadcom Corporation and/or
|
|
-- its licensors, and may only be used, duplicated, modified or distributed
|
|
-- pursuant to the terms and conditions of a separate, written license
|
|
-- agreement executed between you and Broadcom (an "Authorized License").
|
|
-- Except as set forth in an Authorized License, Broadcom grants no license
|
|
-- (express or implied), right to use, or waiver of any kind with respect to
|
|
-- the Software, and Broadcom expressly reserves all rights in and to the
|
|
-- Software and all intellectual property rights therein. IF YOU HAVE NO
|
|
-- AUTHORIZED LICENSE, THEN YOU HAVE NO RIGHT TO USE THIS SOFTWARE IN ANY WAY,
|
|
-- AND SHOULD IMMEDIATELY NOTIFY BROADCOM AND DISCONTINUE ALL USE OF THE
|
|
-- SOFTWARE.
|
|
--
|
|
-- Except as expressly set forth in the Authorized License,
|
|
--
|
|
-- 1. This program, including its structure, sequence and organization,
|
|
-- constitutes the valuable trade secrets of Broadcom, and you shall use all
|
|
-- reasonable efforts to protect the confidentiality thereof, and to use this
|
|
-- information only in connection with your use of Broadcom integrated circuit
|
|
-- products.
|
|
--
|
|
-- 2. TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE SOFTWARE IS PROVIDED
|
|
-- "AS IS" AND WITH ALL FAULTS AND BROADCOM MAKES NO PROMISES, REPRESENTATIONS
|
|
-- OR WARRANTIES, EITHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, WITH
|
|
-- RESPECT TO THE SOFTWARE. BROADCOM SPECIFICALLY DISCLAIMS ANY AND ALL
|
|
-- IMPLIED WARRANTIES OF TITLE, MERCHANTABILITY, NONINFRINGEMENT, FITNESS FOR
|
|
-- A PARTICULAR PURPOSE, LACK OF VIRUSES, ACCURACY OR COMPLETENESS, QUIET
|
|
-- ENJOYMENT, QUIET POSSESSION OR CORRESPONDENCE TO DESCRIPTION. YOU ASSUME
|
|
-- THE ENTIRE RISK ARISING OUT OF USE OR PERFORMANCE OF THE SOFTWARE.
|
|
--
|
|
-- 3. TO THE MAXIMUM EXTENT PERMITTED BY LAW, IN NO EVENT SHALL BROADCOM
|
|
-- OR ITS LICENSORS BE LIABLE FOR (i) CONSEQUENTIAL, INCIDENTAL, SPECIAL,
|
|
-- INDIRECT, OR EXEMPLARY DAMAGES WHATSOEVER ARISING OUT OF OR IN ANY WAY
|
|
-- RELATING TO YOUR USE OF OR INABILITY TO USE THE SOFTWARE EVEN IF BROADCOM
|
|
-- HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES; OR (ii) ANY AMOUNT IN
|
|
-- EXCESS OF THE AMOUNT ACTUALLY PAID FOR THE SOFTWARE ITSELF OR U.S. $1,
|
|
-- WHICHEVER IS GREATER. THESE LIMITATIONS SHALL APPLY NOTWITHSTANDING ANY
|
|
-- FAILURE OF ESSENTIAL PURPOSE OF ANY LIMITED REMEDY.
|
|
--
|
|
--****************************************************************************
|
|
-- Filename: brcm-cm-emta-mgmt.mib
|
|
-- Author: Kevin O'Neal
|
|
-- Creation Date: August 9, 2007
|
|
--
|
|
--****************************************************************************
|
|
-- Description:
|
|
--
|
|
-- private MIB for runtime (not factory) eMTA management
|
|
--
|
|
--****************************************************************************
|
|
-- Revision History:
|
|
--
|
|
--**************************************************************************
|
|
|
|
BRCM-CM-EMTA-MGMT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
OBJECT-GROUP,
|
|
MODULE-COMPLIANCE,
|
|
NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
cmEmbeddedDevices
|
|
FROM BRCM-CM-MGMT-MIB;
|
|
|
|
cmEmtaMgmt MODULE-IDENTITY
|
|
LAST-UPDATED "200902240000Z"
|
|
ORGANIZATION "Broadcom Corporation"
|
|
CONTACT-INFO
|
|
" BANANA-CABLEDATA
|
|
(cableData branch of the
|
|
Broadcom Assigned Numbers and Naming Authority)
|
|
Broadcom Corporation
|
|
|
|
Postal: 4385 River Green Parkway
|
|
Duluth, GA 30096
|
|
USA
|
|
|
|
Tel: +1 770 232-0018
|
|
|
|
E-mail: banana-cabledata@broadcom.com"
|
|
DESCRIPTION
|
|
"Broadcom MIB for runtime management of CM features which are only
|
|
applicable on a device which contains an embedded PacketCable MTA."
|
|
REVISION "200902240000Z"
|
|
DESCRIPTION
|
|
"Added object cmEmtaPingTestInterval, cmEmtaPingTestFailEMTAThreshold, and
|
|
cmEmtaPingTestFailCMThreshold."
|
|
REVISION "200806121200Z"
|
|
DESCRIPTION
|
|
"Added object cmEmtaSafeReset."
|
|
REVISION "200806120000Z"
|
|
DESCRIPTION
|
|
"Added object cmEmtaRegistrationState."
|
|
REVISION "200708300000Z"
|
|
DESCRIPTION
|
|
"Added objects cmEmtaNonSecureFlowDefaultReadCommunity and
|
|
cmEmtaNonSecureFlowDefaultWriteCommunity."
|
|
REVISION "200708090000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { cmEmbeddedDevices 1 }
|
|
|
|
--
|
|
-- Placeholder for any future textual conventions
|
|
--
|
|
|
|
--
|
|
-- Placeholder for any future notifications (traps)
|
|
--
|
|
cmEmtaNotification OBJECT IDENTIFIER ::= { cmEmtaMgmt 0 }
|
|
|
|
--
|
|
-- Management objects
|
|
--
|
|
cmEmtaMIBObjects OBJECT IDENTIFIER ::= { cmEmtaMgmt 1 }
|
|
|
|
--
|
|
-- cmEmtaBase - objects for general-purpose CM - eMTA control
|
|
--
|
|
|
|
cmEmtaBase OBJECT IDENTIFIER ::= { cmEmtaMIBObjects 1 }
|
|
|
|
cmEmtaBasicFlowDhcpAccept OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object may be used to expedite the acceptance of the EMTA DHCP
|
|
offer when option 122.6 of the offer indicates basic or hybrid
|
|
provisioning flow.
|
|
|
|
If set to true(1), DHCP offer rule (b) from MTA initialization flow
|
|
MTA2 will not be enforced. This means that the EMTA will not retry
|
|
the DHCP discover process in search of an offer which specifies the
|
|
secure flow, thus resulting in the EMTA becoming operational more
|
|
quickly.
|
|
|
|
It is important to note that in this configuration the CM is in
|
|
violation of the PacketCable provisioning specification."
|
|
REFERENCE
|
|
"PacketCable 1.5 Specification MTA Device Provisioning
|
|
PKT-SP-PROV1.5-I03-070412, section 7.2.1, initialization flow MTA2"
|
|
DEFVAL { false }
|
|
::= { cmEmtaBase 1 }
|
|
|
|
cmEmtaNonSecureFlowDefaultReadCommunity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default community string which will be used for read-only access
|
|
in the EMTA non-secure provisioning flow. When read, this object will
|
|
always return an empty string."
|
|
DEFVAL { "private" }
|
|
::= { cmEmtaBase 2 }
|
|
|
|
cmEmtaNonSecureFlowDefaultWriteCommunity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default community string which will be used for read-write access
|
|
in the EMTA non-secure provisioning flow. When read, this object will
|
|
always return an empty string."
|
|
DEFVAL { "private" }
|
|
::= { cmEmtaBase 3 }
|
|
|
|
cmEmtaRegistrationState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cmScanning(1),
|
|
cmRanging(2),
|
|
cmDhcp(3),
|
|
cmTftp(4),
|
|
cmRegistered(5),
|
|
mtaDhcp(6),
|
|
mtaTftp(7),
|
|
mtaProvisioned(8),
|
|
mtaRsip(9),
|
|
mtaOperational(10),
|
|
mtaRejected(11)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current state of the CM and EMTA provisioning and
|
|
registration process."
|
|
::= { cmEmtaBase 4 }
|
|
|
|
cmEmtaSafeReset OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to true(1) will cause the device to reset only
|
|
when all telephony lines are on-hook. If one or more lines are
|
|
off-hook when the reset is invoked then the reset will be queued and
|
|
will occur once all lines are on-hook. Reading this object returns
|
|
false(2) unless a reset is pending, in which case it returns true(1).
|
|
A pending reset may be cancelled by setting this object to false(2).
|
|
|
|
Note that the behavior of this object is also affected by the values of
|
|
objects emtaPostCallCompletionResetDelay and emtaMaxResetDelay as
|
|
described in the the BRCM-EMTA-MGMT-MIB."
|
|
::= { cmEmtaBase 5 }
|
|
|
|
cmEmtaPingTestInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the time interval, in minutes, that the eMTA should
|
|
perform a ping test from the eMTA stack to the default gateway. If set to
|
|
0, this feature will be disabled."
|
|
DEFVAL {0}
|
|
::= { cmEmtaBase 6 }
|
|
|
|
cmEmtaPingTestFailEMTAThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of consecutive failed ping tests to
|
|
trigger an eMTA reset. If set to 0, this feature will be disabled."
|
|
DEFVAL {0}
|
|
::= { cmEmtaBase 7 }
|
|
|
|
cmEmtaPingTestFailCMThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of consecutive failed ping tests to
|
|
trigger a CM reset and eMTA reset.
|
|
If set to 0, this feature will be disabled."
|
|
DEFVAL {0}
|
|
::= { cmEmtaBase 8 }
|
|
|
|
|
|
--
|
|
-- Conformance definitions
|
|
--
|
|
cmEmtaConformance OBJECT IDENTIFIER ::= { cmEmtaMgmt 2 }
|
|
|
|
--
|
|
-- Compliance Statements
|
|
--
|
|
cmEmtaCompliances OBJECT IDENTIFIER ::= { cmEmtaConformance 1 }
|
|
cmEmtaGroups OBJECT IDENTIFIER ::= { cmEmtaConformance 2 }
|
|
|
|
cmEmtaCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for cablemodem devices which include an
|
|
embedded PacketCable MTA."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
cmEmtaBaseGroup
|
|
}
|
|
::= { cmEmtaCompliances 1 }
|
|
|
|
|
|
cmEmtaBaseGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmEmtaBasicFlowDhcpAccept,
|
|
cmEmtaNonSecureFlowDefaultReadCommunity,
|
|
cmEmtaNonSecureFlowDefaultWriteCommunity,
|
|
cmEmtaRegistrationState,
|
|
cmEmtaSafeReset
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of objects supported by all agents which implement this MIB."
|
|
::= { cmEmtaGroups 1 }
|
|
|
|
END
|
|
|