Observium_CE/mibs/bintec/BIANCA-X8000-MIBSYS-MIB

329 lines
9.8 KiB
Plaintext

-- This file is corresponding to Release 9.1.10.101 from 2014/08/11 00:00:00
-- (C)opyright 1991-2014 bintec elmeg GmbH, All Rights Reserved
-- $RCSfile: mibsysx8,v $
-- $Revision: 1.8 $
BIANCA-X8000-MIBSYS-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter, enterprises
FROM RFC1155-SMI
DisplayString
FROM RFC1158-MIB
TRAP-TYPE
FROM RFC-1215
OBJECT-TYPE
FROM RFC-1212;
bintec OBJECT IDENTIFIER ::= { enterprises 272 }
bibo OBJECT IDENTIFIER ::= { bintec 4 }
sys OBJECT IDENTIFIER ::= { bibo 17 }
x8 OBJECT IDENTIFIER ::= { sys 3 }
sysX8Config OBJECT IDENTIFIER
::= { x8 1 }
sysX8Traps OBJECT IDENTIFIER ::= { x8 2 }
-- System Status and Configuration
sysX8ConfigPowerSupply1State OBJECT-TYPE
SYNTAX INTEGER { missing(1), off(2), running(3), fail(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shows the state of the power supply."
::= { sysX8Config 1 }
sysX8ConfigPowerSupply1Temp OBJECT-TYPE
SYNTAX INTEGER (0..250)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shows the actual power supply temperature
in the unit Celsius."
::= { sysX8Config 2 }
sysX8ConfigPowerSupply1TempAlarmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..250)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Power supply 1 temperature threshold."
DEFVAL { 40 }
::= { sysX8Config 3 }
sysX8ConfigPowerSupply1TempAlarmTrap OBJECT-TYPE
SYNTAX INTEGER { normal(1), critical(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If the power supply temperature raises above the threshold,
a alarm trap is generated every 60 seconds."
::= { sysX8Config 4 }
sysX8ConfigPowerSupply2State OBJECT-TYPE
SYNTAX INTEGER { missing(1), off(2), running(3), fail(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable show the the state of the power supply."
::= { sysX8Config 5 }
sysX8ConfigPowerSupply2Temp OBJECT-TYPE
SYNTAX INTEGER (0..250)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shows the actual power supply temperature
in the unit Celsius."
::= { sysX8Config 6 }
sysX8ConfigPowerSupply2TempAlarmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..250)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Power supply 2 temperature threshold."
DEFVAL { 40 }
::= { sysX8Config 7 }
sysX8ConfigPowerSupply2TempAlarmTrap OBJECT-TYPE
SYNTAX INTEGER { normal(1), critical(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If the power supply temperature raises above the threshold,
a alarm trap is generated every 60 seconds."
::= { sysX8Config 8 }
sysX8ConfigFanControl OBJECT-TYPE
SYNTAX INTEGER { auto(1), high(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable defines automatic fan control.
In mode 'auto' the fans are automatically adjusted
depending on the current temperature.
In mode 'high' all fans remain at maximum speed."
DEFVAL { high }
::= { sysX8Config 9 }
sysX8ConfigFanVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shows the firmware version of
the fan unit."
::= { sysX8Config 10 }
sysX8ConfigFan1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shows the current turning speed."
::= { sysX8Config 11 }
sysX8ConfigFan2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shows the current turning speed."
::= { sysX8Config 12 }
sysX8ConfigFan3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shows the current turning speed."
::= { sysX8Config 13 }
sysX8ConfigFan4 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shows the current turning speed."
::= { sysX8Config 14 }
---
--- System Status and Configuration Traps
---
sysX8TrapPowerSupply1Missing TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply1State,
sysX8ConfigPowerSupply1Temp,
sysX8ConfigPowerSupply1TempAlarmTrap
}
DESCRIPTION "This trap signifies that the power supply 1
has been removed"
::= 1
sysX8TrapPowerSupply1PowerOff TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply1State,
sysX8ConfigPowerSupply1Temp,
sysX8ConfigPowerSupply1TempAlarmTrap
}
DESCRIPTION "This trap signifies that the power supply 1
has no power-good signal (no power input)"
::= 2
sysX8TrapPowerSupply1PowerFail TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply1State,
sysX8ConfigPowerSupply1Temp,
sysX8ConfigPowerSupply1TempAlarmTrap
}
DESCRIPTION "This trap signifies that the power supply 1
has been in the failure (bad DC output)"
::= 3
sysX8TrapPowerSupply1PowerGood TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply1State,
sysX8ConfigPowerSupply1Temp,
sysX8ConfigPowerSupply1TempAlarmTrap
}
DESCRIPTION "This trap signifies that the power supply 1
is running (supplying power)"
::= 4
sysX8TrapPowerSupply1TempCritical TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply1State,
sysX8ConfigPowerSupply1Temp,
sysX8ConfigPowerSupply1TempAlarmThreshold
}
DESCRIPTION "This trap signifies that the power supply 1 temperature
raises above the critical alarm-threshold"
::= 5
sysX8TrapPowerSupply1TempOk TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply1State,
sysX8ConfigPowerSupply1Temp,
sysX8ConfigPowerSupply1TempAlarmThreshold
}
DESCRIPTION "A normal power supply 1 temperature has been restored."
::= 6
sysX8TrapPowerSupply2Missing TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply2State,
sysX8ConfigPowerSupply2Temp,
sysX8ConfigPowerSupply2TempAlarmThreshold
}
DESCRIPTION "This trap signifies that the power supply 2
has been removed"
::= 7
sysX8TrapPowerSupply2PowerOff TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply2State,
sysX8ConfigPowerSupply2Temp,
sysX8ConfigPowerSupply2TempAlarmThreshold
}
DESCRIPTION "This trap signifies that the power supply 2
has no power-good signal (no power input)"
::= 8
sysX8TrapPowerSupply2PowerFail TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply2State,
sysX8ConfigPowerSupply2Temp,
sysX8ConfigPowerSupply2TempAlarmThreshold
}
DESCRIPTION "This trap signifies that the power supply 2
has been in the failure (bad DC output)"
::= 9
sysX8TrapPowerSupply2PowerGood TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply2State,
sysX8ConfigPowerSupply2Temp,
sysX8ConfigPowerSupply2TempAlarmThreshold
}
DESCRIPTION "This trap signifies that the power supply 2
is running (supplying power)"
::= 10
sysX8TrapPowerSupply2TempCritical TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply2State,
sysX8ConfigPowerSupply2Temp,
sysX8ConfigPowerSupply2TempAlarmThreshold
}
DESCRIPTION "This trap signifies that the power supply 2 temperature
raises above the critical alarm-threshold"
::= 11
sysX8TrapPowerSupply2TempOk TRAP-TYPE
ENTERPRISE sysX8Traps
VARIABLES {
sysDescr,
sysName,
sysX8ConfigPowerSupply2State,
sysX8ConfigPowerSupply2Temp,
sysX8ConfigPowerSupply2TempAlarmThreshold
}
DESCRIPTION "A normal power supply 2 temperature has been restored."
::= 12
END