-- This file is corresponding to Release 9.1.10.101 from 2014/08/11 00:00:00
|
|
|
|
|
|
-- (C)opyright 1991-2014 bintec elmeg GmbH, All Rights Reserved
|
|
-- $RCSfile: mibsec,v $
|
|
-- $Revision: 1.55 $
|
|
|
|
BIANCA-BRICK-SEC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Counter, enterprises
|
|
FROM RFC1155-SMI
|
|
|
|
DisplayString
|
|
FROM RFC1158-MIB
|
|
|
|
BitValue, HexValue
|
|
FROM BINTEC-MIB
|
|
|
|
OBJECT-TYPE
|
|
FROM RFC-1212;
|
|
|
|
bintec OBJECT IDENTIFIER ::= { enterprises 272 }
|
|
bintecsec OBJECT IDENTIFIER
|
|
::= { bintec 254 }
|
|
biboAdmAdminCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"The Community name used for admin access"
|
|
DEFVAL { "bintec" }
|
|
::= { bintecsec 1 }
|
|
|
|
biboAdmReadCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"The Community name used for read-only access."
|
|
DEFVAL { "public" }
|
|
::= { bintecsec 2 }
|
|
|
|
biboAdmWriteCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"The Community name used for read-write access."
|
|
DEFVAL { "public" }
|
|
::= { bintecsec 3 }
|
|
|
|
biboAdmLicenseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BiboAdmLicenseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the licenses, purchased for this
|
|
BIANCA/BRICK. Each entry describes a license. Each
|
|
license can enable one or more features of the
|
|
BIANCA/BRICK, when the activation key is correct.
|
|
Please Note, that a license is only valid for the
|
|
BIANCA/BRICK it has been purchased for."
|
|
::= { bintecsec 4 }
|
|
|
|
biboAdmLicenseEntry OBJECT-TYPE
|
|
SYNTAX BiboAdmLicenseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
INDEX { biboAdmLicenseKey }
|
|
::= { biboAdmLicenseTable 1 }
|
|
|
|
BiboAdmLicenseEntry ::=
|
|
SEQUENCE {
|
|
biboAdmLicenseSerialNumber INTEGER,
|
|
biboAdmLicenseMask INTEGER,
|
|
biboAdmLicenseKey DisplayString,
|
|
biboAdmLicenseState INTEGER,
|
|
|
|
biboAdmLicenseSerialId DisplayString,
|
|
biboAdmLicenseHwSerial DisplayString,
|
|
biboAdmLicenseLicType INTEGER
|
|
}
|
|
|
|
biboAdmLicenseSerialNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..999999)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"This object specifies the serial number of the license in
|
|
case of a numerical license (together with 'Mask' and 'Key')."
|
|
::= { biboAdmLicenseEntry 1 }
|
|
|
|
biboAdmLicenseMask OBJECT-TYPE
|
|
SYNTAX INTEGER (0..8388607)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"The LicenseMask is a bitfield, that specifies the different
|
|
features enabled by the license. (only used on a numerical
|
|
license)."
|
|
::= { biboAdmLicenseEntry 2 }
|
|
|
|
biboAdmLicenseKey OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"This object contains the activation key. A license is only
|
|
valid, if the activation key is correct."
|
|
::= { biboAdmLicenseEntry 3 }
|
|
|
|
biboAdmLicenseState OBJECT-TYPE
|
|
SYNTAX INTEGER { ok(1), not-ok(2), delete(3), internal-ok(4),
|
|
internal-erase(5), not-supported(6) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"To delete a license from the system, this object has
|
|
to be set to delete. In case of an 'internal-ok' license the
|
|
license can be erased from the modules EEPROM, if it is set
|
|
to 'internal-erase'.
|
|
The state will be 'not-supported' if a license refers to
|
|
a feature which is not supported by the image loaded.
|
|
With 'delete' it is only deleted from the main board
|
|
flash memory."
|
|
DEFVAL { not-ok }
|
|
::= { biboAdmLicenseEntry 4 }
|
|
|
|
biboAdmLicenseSerialId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"This object specifies the serial id string of the license in
|
|
case of string license (together with 'Key')."
|
|
::= { biboAdmLicenseEntry 5 }
|
|
|
|
biboAdmLicenseHwSerial OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"This object contains the device Hardware serial number
|
|
for which the license is purchased for."
|
|
::= { biboAdmLicenseEntry 6 }
|
|
|
|
biboAdmLicenseLicType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ip(1), capi(2), bridge(3), x25(4), ipx(5), stac(6),
|
|
frame-relay(7), tapi(8), ospf(9), extended-lan(10),
|
|
tunneling(11), taf(12), extended-wan(13), leased-line(14),
|
|
e25(29),
|
|
ipsec(33), ipseccb-ipxfer(34), bgp(35),
|
|
uefs(36), siplan(37), siptrunk(38), pim(39),
|
|
call-by-call(40), fax(41), sipout(42), brrp(43),
|
|
wlan-controller(44), terminal-option(45),
|
|
data-encr-accel(46), voice-mail-system(47), pptp(48),
|
|
ethernet(128), bri(129), g703(130), pri(131),
|
|
modem(132), g7032pri(133), slots(134), e3(135),
|
|
serial(136), shdsl(137), vdsl(138)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"The type of licenseable feature."
|
|
::= { biboAdmLicenseEntry 7 }
|
|
|
|
|
|
|
|
biboAdmRadiusSecret OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"The shared secret for RADIUS access."
|
|
DEFVAL { "" }
|
|
::= { bintecsec 5 }
|
|
|
|
biboAdmHttpPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"The password for HTTP access."
|
|
DEFVAL { "bintec" }
|
|
::= { bintecsec 6 }
|
|
|
|
|
|
biboAdmLoginTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BiboAdmLoginEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The biboAdmLoginTable defines additional users and
|
|
their passwords, and the commnd to be executed
|
|
at login."
|
|
::= { bintecsec 7 }
|
|
|
|
biboAdmLoginEntry OBJECT-TYPE
|
|
SYNTAX BiboAdmLoginEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
INDEX { biboAdmLoginUser }
|
|
::= { biboAdmLoginTable 1 }
|
|
|
|
BiboAdmLoginEntry ::=
|
|
SEQUENCE {
|
|
biboAdmLoginUser DisplayString,
|
|
biboAdmLoginPassword DisplayString,
|
|
biboAdmLoginCommand DisplayString,
|
|
biboAdmLoginState INTEGER,
|
|
biboAdmLoginSnmpShellCommand DisplayString,
|
|
biboAdmLoginSNMPAccessLevel INTEGER,
|
|
biboAdmLoginShellAccessLevel INTEGER,
|
|
biboAdmLoginHTTPAccessRights BITS,
|
|
biboAdmLoginGUIAccessLevel INTEGER,
|
|
biboAdmLoginActivityMonAccessLevel INTEGER,
|
|
biboAdmLoginApDiscAccessLevel INTEGER,
|
|
biboAdmLoginHTTPAccessClass INTEGER,
|
|
biboAdmLoginGUIAccessMask HexValue,
|
|
biboAdmLoginGUIWriteAccessMask HexValue,
|
|
biboAdmLoginPasswordChangeRequired INTEGER
|
|
}
|
|
|
|
biboAdmLoginUser OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"This is the login name."
|
|
::= { biboAdmLoginEntry 1 }
|
|
|
|
biboAdmLoginPassword OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"This is the user password."
|
|
::= { biboAdmLoginEntry 2 }
|
|
|
|
biboAdmLoginCommand OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This is the command, which is started at login,
|
|
e.g. sh, telnet. All external commands are possible.
|
|
|
|
Variable got replaced by biboAdmLoginSnmpShellCommand."
|
|
::= { biboAdmLoginEntry 3 }
|
|
|
|
biboAdmLoginState OBJECT-TYPE
|
|
SYNTAX INTEGER { valid(1), delete(2), invalid(3) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"The variable is used to disable or discard the entry."
|
|
DEFVAL { valid }
|
|
::= { biboAdmLoginEntry 4 }
|
|
|
|
biboAdmLoginSnmpShellCommand OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"This is the command, which is started upon shell login;
|
|
examples are 'telnet <IPaddr>', 'ifstat' or 'ps -ef'.
|
|
All external commands are possible, SNMP as well as all other
|
|
internal commands can be emulated via:
|
|
|
|
sh -c '<cmd>[;<cmd> ... ]'
|
|
|
|
Obsoletes biboAdmLoginCommand."
|
|
::= { biboAdmLoginEntry 5 }
|
|
|
|
biboAdmLoginSNMPAccessLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no-access(1),
|
|
read(2),
|
|
write(3),
|
|
admin(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Define SNMP access level for account.
|
|
Available access levels are:
|
|
no-access(1),
|
|
read(2),
|
|
write(3),
|
|
admin(4)
|
|
They match SNMP communities but for value no-access which
|
|
disables SNMP access for that account.
|
|
|
|
Default value is no-access in order to avoid unintentionally
|
|
granting access rights."
|
|
DEFVAL { no-access }
|
|
::= { biboAdmLoginEntry 6 }
|
|
|
|
biboAdmLoginShellAccessLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Define Shell access level for account.
|
|
Available access levels are 0 and 1, basically switching shell
|
|
access off or on, respectively.
|
|
|
|
Default value is 0 in order to avoid unintentionally granting
|
|
access rights."
|
|
DEFVAL { 0 }
|
|
::= { biboAdmLoginEntry 7 }
|
|
|
|
biboAdmLoginHTTPAccessRights OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
admin(0),
|
|
fci(1),
|
|
maint(2),
|
|
easp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Define HTTP access rights for account which are defined as bit field.
|
|
Available access right bits are currently:
|
|
bit 0: admin - access to any and all pages
|
|
bit 1: fci - access to web configuration interface
|
|
bit 2: maint - access to system maintenance pages
|
|
(update of images, import and export of configurations
|
|
and the like)
|
|
bit 3: easp - access to pages dedicated for use by external
|
|
applications (currently only Dime Manager)
|
|
|
|
If bit 0 (admin) is set, all other bit values are ignored and assumed
|
|
as set (i.e. access allowed). This allows for defining unrestricted access
|
|
in a forward-compatible manner even when new bits should be
|
|
introduced.
|
|
|
|
A value of 0 turns HTTP access off completely.
|
|
Other values grant HTTP access in an application dependent
|
|
manner; each value may be interpreted differently on different
|
|
products.
|
|
|
|
Default value is 0 in order to avoid unintentionally granting
|
|
access rights."
|
|
DEFVAL { { } }
|
|
::= { biboAdmLoginEntry 8 }
|
|
|
|
biboAdmLoginGUIAccessLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS obsolete
|
|
|
|
DESCRIPTION
|
|
"Define GUI access level for account.
|
|
Available access levels reach from 0 to 255.
|
|
|
|
Value 0 turns GUI access off, value 1 defines allmighty
|
|
administrator role.
|
|
Other values grant GUI access in an application dependend
|
|
manner; each value may be interpreted differently on different
|
|
products.
|
|
|
|
Default value is 0 in order to avoid unintentinoally granting
|
|
access rights."
|
|
DEFVAL { 0 }
|
|
::= { biboAdmLoginEntry 9 }
|
|
|
|
biboAdmLoginActivityMonAccessLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Define activitiy monitor access level for account.
|
|
|
|
Value 0 inhibits any means of influencing system by activity
|
|
monitor mechanisms.
|
|
Value 1 grants full access.
|
|
|
|
NOTE:
|
|
This variable is currently only valid for special users
|
|
admin and write (SNMP communities).
|
|
For all other users it is ignored.
|
|
|
|
Default value is 0 in order to avoid unintentinoally granting
|
|
access rights."
|
|
DEFVAL { 0 }
|
|
::= { biboAdmLoginEntry 10 }
|
|
|
|
biboAdmLoginApDiscAccessLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Define access level for access point discovery instances.
|
|
|
|
Value 0 inhibits any means of influencing system by access
|
|
point discovery mechanisms.
|
|
Value 1 grants full access.
|
|
|
|
NOTE:
|
|
This variable is currently only valid for special user admin
|
|
(SNMP community).
|
|
For all other users it is ignored.
|
|
|
|
Default value is 0."
|
|
DEFVAL { 0 }
|
|
::= { biboAdmLoginEntry 11 }
|
|
|
|
biboAdmLoginHTTPAccessClass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
user(1),
|
|
admin(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Define SNMP access class for account.
|
|
Available access levels are:
|
|
user(1),
|
|
admin(2),
|
|
|
|
HTTP access class allows HTTP sessions to be classified and
|
|
realize limitation of HTTP sessions while allowing for
|
|
prioritizing sessions over user sessions. This ensures
|
|
manageability of the system even if normal users flood system
|
|
with their requests.
|
|
|
|
Default value is user."
|
|
DEFVAL { user }
|
|
::= { biboAdmLoginEntry 12 }
|
|
|
|
biboAdmLoginGUIAccessMask OBJECT-TYPE
|
|
SYNTAX HexValue
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Define GUI access level bits for account.
|
|
Available access levels bits reach from 0 to 30
|
|
|
|
Value 0 turns GUI access off,
|
|
bit 0 (value 1) is reserved
|
|
bit 1 (value 2) defines almighty administrator role.
|
|
Other values grant GUI access depending on
|
|
biboAdmGuiAccessTable entries. The default behavior (if
|
|
there is no entry in biboAdmGuiAccessTable) is application
|
|
dependent; each value may be interpreted differently on
|
|
different products.
|
|
|
|
Default value is 0 in order to avoid unintentionally granting
|
|
access rights."
|
|
DEFVAL { 0 }
|
|
::= { biboAdmLoginEntry 13 }
|
|
|
|
|
|
biboAdmLoginGUIWriteAccessMask OBJECT-TYPE
|
|
SYNTAX HexValue
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Define GUI write access level bits for account.
|
|
Available write access levels bits reach from 0 to 30
|
|
|
|
Value 0 turns GUI write access off,
|
|
bit 0 (value 1) is reserved
|
|
bit 1 (value 2) defines almighty administrator role.
|
|
Other values grant GUI access depending on
|
|
biboAdmGuiAccessTable entries. The default behavior
|
|
(if there is no entry in biboAdmGuiAccessTable) is
|
|
application dependent; each value may be interpreted
|
|
differently on different products."
|
|
DEFVAL { 0x7FFFFFFE }
|
|
::= { biboAdmLoginEntry 14 }
|
|
|
|
biboAdmLoginPasswordChangeRequired OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"If biboAdmLoginPasswordChangeRequired is set to enabled
|
|
the GUI demands a password change for this user at the
|
|
next login. After the password change GUI sets this value
|
|
to disabled."
|
|
DEFVAL { disabled }
|
|
::= { biboAdmLoginEntry 15 }
|
|
|
|
biboAdmPublicKey OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Generated public key for TAF client access"
|
|
::= { bintecsec 10 }
|
|
|
|
biboAdmPrivateKey OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
""
|
|
::= { bintecsec 11 }
|
|
|
|
biboAdmActMonPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"The password for Activity Monitor access."
|
|
DEFVAL { "" }
|
|
::= { bintecsec 12 }
|
|
|
|
-- bintecsec 13 is used for tacacsp
|
|
|
|
-- biboAdmGuiAccessTable
|
|
biboAdmGuiAccessTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BiboAdmGuiAccessEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The biboAdmGuiAccessTable defines 'required access level' for
|
|
GUI access IDs."
|
|
::= { bintecsec 14 }
|
|
|
|
biboAdmGuiAccessEntry OBJECT-TYPE
|
|
SYNTAX BiboAdmGuiAccessEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
INDEX { biboAdmGuiAccessIndex }
|
|
::= { biboAdmGuiAccessTable 1 }
|
|
|
|
BiboAdmGuiAccessEntry ::=
|
|
SEQUENCE {
|
|
biboAdmGuiAccessIndex INTEGER,
|
|
-- biboAdmGuiAccessID DisplayString,
|
|
biboAdmGuiAccessState INTEGER,
|
|
biboAdmGuiAccessRequiredLvlMask HexValue
|
|
}
|
|
|
|
biboAdmGuiAccessIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The GUI access index of the associated id."
|
|
::= { biboAdmGuiAccessEntry 1 }
|
|
|
|
-- biboAdmGuiAccessID OBJECT-TYPE
|
|
-- SYNTAX DisplayString (SIZE (0..50))
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
--
|
|
-- DESCRIPTION
|
|
-- "This is the GUI access id."
|
|
--
|
|
-- ::= { biboAdmGuiAccessEntry 2 }
|
|
|
|
biboAdmGuiAccessState OBJECT-TYPE
|
|
SYNTAX INTEGER { valid(1), delete(2), invalid(3) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Make entry valid/invalid or discard it."
|
|
DEFVAL { valid }
|
|
::= { biboAdmGuiAccessEntry 3 }
|
|
|
|
biboAdmGuiAccessRequiredLvlMask OBJECT-TYPE
|
|
|
|
SYNTAX HexValue
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Define required GUI access level bits.
|
|
Available access levels bits reach from 0 to 30
|
|
Normal behavior: Only users get access to the part of GUI
|
|
which is specified by biboAdmGuiAccessInedx, which have at
|
|
least one bit set in biboAdmLoginGUIAccessMaks which is
|
|
also set in here.
|
|
|
|
System administrator and users which have admin rights
|
|
(bit 1 (2)) in biboAdmLoginGUIAccessLevel have always
|
|
access to any GUI part. This can be overruled by setting
|
|
bit 0 in biboAdmGuiAccessRequiredLevel."
|
|
DEFVAL { 0 }
|
|
::= { biboAdmGuiAccessEntry 4 }
|
|
|
|
|
|
biboAdmGuiAccessLevelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BiboAdmGuiAccessLevelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"This table holds a description for used
|
|
level bits."
|
|
::= { bintecsec 15 }
|
|
|
|
biboAdmGuiAccessLevelEntry OBJECT-TYPE
|
|
SYNTAX BiboAdmGuiAccessLevelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
INDEX { biboAdmGuiAccessLevelBitNr }
|
|
::= { biboAdmGuiAccessLevelTable 1 }
|
|
|
|
BiboAdmGuiAccessLevelEntry ::=
|
|
SEQUENCE {
|
|
biboAdmGuiAccessLevelBitNr INTEGER,
|
|
biboAdmGuiAccessLevelState INTEGER,
|
|
biboAdmGuiAccessLevelDescription DisplayString
|
|
}
|
|
|
|
biboAdmGuiAccessLevelBitNr OBJECT-TYPE
|
|
SYNTAX INTEGER (0..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Access level bit."
|
|
|
|
::= { biboAdmGuiAccessLevelEntry 1 }
|
|
|
|
biboAdmGuiAccessLevelState OBJECT-TYPE
|
|
SYNTAX INTEGER { valid(1), delete(2), invalid(3) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Make entry valid/invalid or discard it."
|
|
DEFVAL { valid }
|
|
::= { biboAdmGuiAccessLevelEntry 2 }
|
|
|
|
biboAdmGuiAccessLevelDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Description for this access level bit."
|
|
|
|
::= { biboAdmGuiAccessLevelEntry 3 }
|
|
|
|
END
|