-- This file is corresponding to Release 9.1.10.101 from 2014/08/11 00:00:00
-- (C)opyright 2002-2014 bintec elmeg GmbH, All Rights Reserved
-- $RCSfile: mibping,v $
-- $Revision: 1.10 $
-- $Id: mibping,v 1.10 2014-02-07 10:37:50 tsbogend Exp $"
BIANCA-BRICK-PING-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, enterprises
FROM RFC1155-SMI
DisplayString
FROM RFC1158-MIB
OBJECT-TYPE
FROM RFC-1212;
bintec OBJECT IDENTIFIER ::= { enterprises 272 }
bibo OBJECT IDENTIFIER ::= { bintec 4 }
biboip OBJECT IDENTIFIER ::= { bibo 5 }
biboping OBJECT IDENTIFIER
::= { biboip 27 }
biboPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF BiboPingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The biboPingTable contains entries which are used
to request the router to ping a target host for test
purposes."
::= { biboping 1 }
biboPingEntry OBJECT-TYPE
SYNTAX BiboPingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Contains parameters for the ping and results of the
operation.
To create a new entry, do an SNMP SET request
including a biboPingIndex value which is not in use.
To delete an existing entry, do an SNMP SET request
including a biboPingStatus value equal to delete (6)."
INDEX { biboPingIndex }
::= { biboPingTable 1 }
BiboPingEntry ::=
SEQUENCE {
biboPingIndex INTEGER,
biboPingStatus INTEGER,
biboPingCompleted INTEGER,
biboPingSourceAddress IpAddress,
biboPingAddress IpAddress,
biboPingPacketCount INTEGER,
biboPingPacketSize INTEGER,
biboPingPacketTimeout INTEGER,
biboPingReceivedPackets INTEGER,
biboPingMinRoundTrip INTEGER,
biboPingMaxRoundTrip INTEGER,
biboPingAvgRoundTrip INTEGER,
biboPingTTL INTEGER,
biboPingTOS INTEGER
}
biboPingIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The unique index of the entry."
DEFVAL { 1 }
::= { biboPingEntry 1 }
biboPingStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
notinservice(2),
notready(3),
createandgo(4),
createandwait(5),
delete(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current status of the entry or a request
to discard it (delete)."
DEFVAL { createandwait }
::= { biboPingEntry 2 }
biboPingCompleted OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The completion status of the ping session."
DEFVAL { false }
::= { biboPingEntry 3 }
biboPingSourceAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The source ip-address for the ping session."
::= { biboPingEntry 4 }
biboPingAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The target ip-address for the ping session."
::= { biboPingEntry 5 }
biboPingPacketCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of ping packets to send. 0 means
continuous send."
DEFVAL { 4 }
::= { biboPingEntry 6 }
biboPingPacketSize OBJECT-TYPE
SYNTAX INTEGER (8..4096)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The size of each ping packet in bytes."
DEFVAL { 64 }
::= { biboPingEntry 7 }
biboPingPacketTimeout OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time in milliseconds to wait for
a reply before deciding the packet is lost."
DEFVAL { 1000 }
::= { biboPingEntry 8 }
biboPingReceivedPackets OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of replies received so far."
DEFVAL { 0 }
::= { biboPingEntry 9 }
biboPingMinRoundTrip OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum round trip time in milliseconds for
all the packets which have been replied to."
DEFVAL { 0 }
::= { biboPingEntry 10 }
biboPingMaxRoundTrip OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum round trip time in milliseconds for
all the packets which have been replied to."
DEFVAL { 0 }
::= { biboPingEntry 11 }
biboPingAvgRoundTrip OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The average round trip time in milliseconds for
all the packets which have been replied to."
DEFVAL { 0 }
::= { biboPingEntry 12 }
biboPingTTL OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The TTL byte value for each packet (0 = IP default)."
DEFVAL { 0 }
::= { biboPingEntry 13 }
biboPingTOS OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The TOS byte value for each packet."
DEFVAL { 0 }
::= { biboPingEntry 14 }
END