Observium_CE/mibs/atto/ATTO6500N-MIB

1110 lines
39 KiB
Plaintext

-------------------------------------------------------------------------------
--
-- FILE ATTO 6500N Private SNMP MIB
--
-- DESCRIPTION 6500N SNMP Management Information Base
--
-- THIS PROGRAM AND THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF
-- ATTO TECHNOLOGY, INC. AND SHALL NOT BE REPRODUCED, COPIED, OR USED IN
-- WHOLE OR IN PART OTHER THAN AS PROVIDED FOR IN THE LICENSE AGREEMENT
-- PURSUANT TO WHICH IT WAS FURNISHED.
--
-- COPYRIGHT (c) ATTO TECHNOLOGY, INC. 2013
-- ALL RIGHTS RESERVED.
--
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
-- Standard version
-------------------------------------------------------------------------------
ATTO6500N-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString
FROM SNMPv2-TC
NOTIFICATION-TYPE, OBJECT-TYPE, MODULE-IDENTITY,
enterprises, Integer32
FROM SNMPv2-SMI
DateAndTime, TimeInterval, TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF;
--
-- According to ftp://ftp.isi.edu/in-notes/iana/assignments/enterprise-numbers,
-- ATTO's enterprise number is registered as being 4597.
--
bridge MODULE-IDENTITY
LAST-UPDATED "201304190000Z" -- 19 Apr, 2013
ORGANIZATION "ATTO Technology, Inc."
CONTACT-INFO
"ATTO"
DESCRIPTION
"ATTO 6500N Custom MIB"
REVISION "201304190000Z"
DESCRIPTION
"Corrected table entries, names, types and max-access fields."
REVISION "201304160000Z"
DESCRIPTION
"Modified Trap Definitions"
::= { attoMgmt 3 }
attotech OBJECT IDENTIFIER ::= { enterprises 4547 }
attoProducts OBJECT IDENTIFIER ::= { attotech 1 }
attoMgmt OBJECT IDENTIFIER ::= { attotech 2 }
attoModules OBJECT IDENTIFIER ::= { attotech 3 }
attoAgentCapability OBJECT IDENTIFIER ::= { attotech 4 }
bridgeTraps OBJECT IDENTIFIER ::= { bridge 0 }
bridgeIdentity OBJECT IDENTIFIER ::= { bridge 1 }
bridgeChassis OBJECT IDENTIFIER ::= { bridge 2 }
bridgePorts OBJECT IDENTIFIER ::= { bridge 3 }
bridgeConfig OBJECT IDENTIFIER ::= { bridge 4 }
bridgeTrapInfo OBJECT IDENTIFIER ::= { bridge 5 }
bridgeMIBConformance OBJECT IDENTIFIER ::= { bridge 6 }
bridgeMIBCompliances OBJECT IDENTIFIER ::= { bridgeMIBConformance 1 }
bridgeMIBGroups OBJECT IDENTIFIER ::= { bridgeMIBConformance 2 }
-------------------------------------------------------------------------------
-- TEXTUAL CONVENTIONS
-------------------------------------------------------------------------------
DisplayWWN ::= TEXTUAL-CONVENTION
DISPLAY-HINT "1x "
STATUS current
DESCRIPTION
" A Fibre Channel/SAS World Wide Name."
SYNTAX OCTET STRING (SIZE (8))
QSFPTech ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Defines the various QSFP Technologies."
SYNTAX INTEGER { unknown(-1), optical(1), activecopper(2), passivecopper(3) }
PHYStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Operational state of a SAS phy"
SYNTAX INTEGER { unknown (-1), online(1), offline(2) }
------------------------------------------------------------------------------
-- MIB Compliance Statements
------------------------------------------------------------------------------
bridgeBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The requirements for a bridge implementation."
MODULE -- This Module --
MANDATORY-GROUPS { bridgeIdentityBasicGroup,
bridgeChassisBasicGroup,
bridgFcPortInfoBasicGroup,
bridgeFcPortStatisicsBasicGroup,
bridgeSasPortInfoBasicGroup,
bridgeSasPortStatisicsBasicGroup,
bridgeConfigBasicGroup,
bridgeTrapInfoBasicGroup,
bridgeTrapsBasicGroup }
::= { bridgeMIBCompliances 1 }
------------------------------------------------------------------------------
-- Units of conformance
------------------------------------------------------------------------------
bridgeIdentityBasicGroup OBJECT-GROUP
OBJECTS { bridgeUniqueId, vendorID, modelName, primaryFirmwareRevision,
primaryFirmwareBuildDate, hardwareVersion,
secondaryFirmwareRevision, secondaryFirmwareBuildDate,
serialNumber, bridgeName }
STATUS current
DESCRIPTION
"The bridge identity information group."
::= { bridgeMIBGroups 1 }
bridgeChassisBasicGroup OBJECT-GROUP
OBJECTS { lastReboot, uptime, lastRebootReason, minimumOperatingTemp,
maximumOperatingTemp, temperatureHighAlertSetting,
temperatureLowAlertSetting, chassisTemperature,
chassisTemperatureStatus, dramSingleBitErrorCount,
chassisThroughputStatus,
fcSFPVendor, fcSFPSerialNum, fcSFPPartNum,
fcSFPDataRateCapability,
sasQSFPVendor, sasQSFPSerialNum,
sasQSFPType, sasQSFPPartNum }
STATUS current
DESCRIPTION
"The bridge chassis information group."
::= { bridgeMIBGroups 2 }
bridgFcPortInfoBasicGroup OBJECT-GROUP
OBJECTS { fcPortPortNumber, fcPortOperationalState,
fcPortAdminState, fcPortDataRateNegotiated,
fcPortConnModeNegotiated, fcPortDataRateConfigured,
fcPortConnModeConfigured, fcPortDataRateCapability,
fcPortNodeName, fcPortPortName,
fcPortPeerName }
STATUS current
DESCRIPTION
"The bridge ports information group."
::= { bridgeMIBGroups 3 }
bridgeFcPortStatisicsBasicGroup OBJECT-GROUP
OBJECTS { fcStatsTxWords,
fcStatsRxWords, fcStatsTimeSinceReset,
fcStatsErrLinkFailure, fcStatsErrLossOfSync,
fcStatsErrInvalidCRC, fcStatsErrInvalidTxWords,
fcStatsErrLipCount, fcStatsErrNOSCount,
fcStatsErrSignalLoss, fcStatsErrPrimitive }
STATUS current
DESCRIPTION
"The bridge ports information group."
::= { bridgeMIBGroups 4 }
bridgeSasPortInfoBasicGroup OBJECT-GROUP
OBJECTS { sasPortPortNumber, sasPortOperationalState,
sasPortPhy1State, sasPortPhy2State,
sasPortPhy3State, sasPortPhy4State,
sasPortAdminState, sasPortDataRateCapability,
sasPortDataRateNegotiated, sasPortAddress }
STATUS current
DESCRIPTION
"The bridge ports information group."
::= { bridgeMIBGroups 5 }
bridgeSasPortStatisicsBasicGroup OBJECT-GROUP
OBJECTS { sasPhyStatsTimeSinceReset, sasPhyStatsErrLinkChanged,
sasPhyStatsErrInvalidCRC, sasPhyStatsErrPhyReset,
sasPhyStatsErrLossOfSync, sasPhyStatsErrDisparityCount,
sasPhyStatsErrInvalidDwords }
STATUS current
DESCRIPTION
"The bridge ports information group."
::= { bridgeMIBGroups 6}
bridgeConfigBasicGroup OBJECT-GROUP
OBJECTS { trapsEnabled, snmpUpdatesEnabled }
STATUS current
DESCRIPTION
"The bridge configuration information group."
::= { bridgeMIBGroups 7 }
bridgeTrapInfoBasicGroup OBJECT-GROUP
OBJECTS { trapMaxClients, trapClientIpAddress, trapClientPort,
trapClientFilter }
STATUS current
DESCRIPTION
"The bridge trap information group."
::= { bridgeMIBGroups 8 }
bridgeTrapsBasicGroup NOTIFICATION-GROUP
NOTIFICATIONS { bridgeTemperatureWarning, fcPortTransition,
sasPortTransition, bridgeThroughputWarning }
STATUS current
DESCRIPTION
"The bridge traps group."
::= { bridgeMIBGroups 9 }
-------------------------------------------------------------------------------
-- OBJECT DEFINITIONS
-------------------------------------------------------------------------------
--
--
-- Bridge Identity
--
bridgeUniqueId OBJECT-TYPE
SYNTAX DisplayWWN
MAX-ACCESS read-only
STATUS current
DESCRIPTION "8-octets uniquely identifying this HW element."
::= { bridgeIdentity 1 }
vendorID OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Vendor ID for this HW element."
::= { bridgeIdentity 2 }
modelName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Product/Model name of this HW element."
::= { bridgeIdentity 3 }
primaryFirmwareRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Build Number, Version Number and Base Version for the firmware on
the primary partition (active firmware image)."
::= { bridgeIdentity 4 }
primaryFirmwareBuildDate OBJECT-TYPE
SYNTAX DateAndTime (SIZE (8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Active firmware image build date and time (no time zone offset)."
::= { bridgeIdentity 5 }
hardwareVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current version of 6500N hardware."
::= { bridgeIdentity 6 }
secondaryFirmwareRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Version Number and Build Number for the firmware on the secondary
partition (backup firmware image)."
::= { bridgeIdentity 7 }
secondaryFirmwareBuildDate OBJECT-TYPE
SYNTAX DateAndTime (SIZE (8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Backup Firmware image build date and time (no time zone offset)."
::= { bridgeIdentity 8 }
serialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number of this HW element."
::= { bridgeIdentity 9 }
bridgeName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "User defined symbolic name assigned to this HW element."
::= { bridgeIdentity 10 }
--
-- Chassis Monitoring
--
lastReboot OBJECT-TYPE
SYNTAX DateAndTime (SIZE (8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Date and time of last reboot."
::= { bridgeChassis 1 }
uptime OBJECT-TYPE
SYNTAX TimeInterval -- Will roll over in 248 days
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Time since last reboot, in units of 0.01 seconds"
::= { bridgeChassis 2 }
lastRebootReason OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Plain text reason for last reboot."
::= { bridgeChassis 3 }
minimumOperatingTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Minimum Safe Operating Temperature, in degrees C"
::= { bridgeChassis 4 }
maximumOperatingTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximum Safe Operating Temperature, in degrees C"
::= { bridgeChassis 5 }
temperatureHighAlertSetting OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "High temperature warning threshold, in degrees C"
::= { bridgeChassis 6 }
temperatureLowAlertSetting OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Low temperature warning threshold, in degrees C"
::= { bridgeChassis 7 }
chassisTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current Chassis Temperature, in degrees C"
::= { bridgeChassis 8 }
chassisTemperatureStatus OBJECT-TYPE
SYNTAX INTEGER { normal(1), warning(2), critical(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current sensor status (normal, warning or critical).
Normal indicates the temperature for this HW element is within
the safe range. Warning indicates that the temperature for this
HW element has passed the warning threshold but is still within
the safe range. Critical indicates that the temperature for this
HW element is not within the safe operating temperature range."
::= { bridgeChassis 9 }
dramSingleBitErrorCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of Single-bit ECC errors since last reboot"
::= { bridgeChassis 10 }
chassisThroughputStatus OBJECT-TYPE
SYNTAX INTEGER { normal(1), warning(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Overall bridge throughput status (normal, warning).
Normal indicates that there is no data bottleneck.
Warning indicates that the aggregate fibre channel
throughput has exceeded 50,000 IOPS."
::= { bridgeChassis 11 }
fcSFPInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF FCSFPInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores configuration information relating to installed FibreChannel SFPs."
::= { bridgeChassis 12 }
sasQSFPInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SASQSFPInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores configuration information relating to installed SAS QSFPs."
::= { bridgeChassis 13 }
--
-- FC SFP Info Table
fcSFPInfoEntry OBJECT-TYPE
SYNTAX FCSFPInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores information about installed fibre channel SFPs."
INDEX { fcSFPIndex }
::= { fcSFPInfoTable 1 }
FCSFPInfoEntry ::= SEQUENCE {
fcSFPIndex Integer32,
fcSFPVendor DisplayString,
fcSFPSerialNum DisplayString,
fcSFPPartNum DisplayString,
fcSFPDataRateCapability INTEGER
}
fcSFPIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Used to index the SFP in the SFP Info table."
::= { fcSFPInfoEntry 1 }
fcSFPVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SFP vendor name"
::= { fcSFPInfoEntry 2 }
fcSFPSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SFP serial number"
::= { fcSFPInfoEntry 3 }
fcSFPPartNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SFP vendor-supplied part number"
::= { fcSFPInfoEntry 4 }
fcSFPDataRateCapability OBJECT-TYPE
SYNTAX INTEGER { gb2(2), gb4(4), gb8(8), gb16(16) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximum data rate capability of the fibre channel SFP."
::= { fcSFPInfoEntry 5 }
--
-- SAS QSFP Info Table
sasQSFPInfoEntry OBJECT-TYPE
SYNTAX SASQSFPInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores information about installed SAS QSFPs."
INDEX { sasQSFPIndex }
::= { sasQSFPInfoTable 1}
SASQSFPInfoEntry ::= SEQUENCE {
sasQSFPIndex Integer32,
sasQSFPVendor DisplayString,
sasQSFPSerialNum DisplayString,
sasQSFPType QSFPTech,
sasQSFPPartNum DisplayString
}
sasQSFPIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Used to index the QSFP in the QSFP Info table."
::= { sasQSFPInfoEntry 1 }
sasQSFPVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "QSFP vendor name"
::= { sasQSFPInfoEntry 2 }
sasQSFPSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "QSFP serial number"
::= { sasQSFPInfoEntry 3 }
sasQSFPType OBJECT-TYPE
SYNTAX QSFPTech
MAX-ACCESS read-only
STATUS current
DESCRIPTION "QSFP type"
::= { sasQSFPInfoEntry 4 }
sasQSFPPartNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "QSFP vendor-supplied part number"
::= { sasQSFPInfoEntry 5 }
--
--
--
-- Bridge Ports
--
fcPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF FCPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores fibre channel specific information for each fibre channel port."
::= { bridgePorts 1 }
fcPortStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcPortStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores fibre channel specific I/O and error statistics
for each fibre channel port."
::= { bridgePorts 2 }
sasPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SASPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores SAS specific information for each
SAS port."
::= { bridgePorts 3 }
sasPhyStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SasPHYStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores SAS specific I/O and error statistics for each SAS PHY."
::= { bridgePorts 4 }
--
-- FcPortEntry table
--
fcPortInfoEntry OBJECT-TYPE
SYNTAX FCPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores state and capability information about
the fibre channel ports."
INDEX { fcPortIndex }
::= { fcPortInfoTable 1}
FCPortInfoEntry ::= SEQUENCE {
fcPortIndex Integer32,
fcPortPortNumber Integer32,
fcPortOperationalState INTEGER,
fcPortAdminState INTEGER,
fcPortDataRateNegotiated INTEGER,
fcPortConnModeNegotiated INTEGER,
fcPortDataRateConfigured INTEGER,
fcPortConnModeConfigured INTEGER,
fcPortDataRateCapability INTEGER,
fcPortNodeName DisplayWWN,
fcPortPortName DisplayWWN,
fcPortPeerName DisplayWWN
}
fcPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Used to index the fibre channel port in the FC Port Entry table."
::= { fcPortInfoEntry 1 }
fcPortPortNumber OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The fibre channel port number."
::= { fcPortInfoEntry 2 }
fcPortOperationalState OBJECT-TYPE
SYNTAX INTEGER { unknown (-1), online(1), offline(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Operational state of the fibre channel port."
::= { fcPortInfoEntry 3 }
fcPortAdminState OBJECT-TYPE
SYNTAX INTEGER { unknown (-1), disabled(1), enabled(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Administrative state of the fibre channel port.
Indicates whether the port is enabled or disabled."
::= { fcPortInfoEntry 4 }
fcPortDataRateNegotiated OBJECT-TYPE
SYNTAX INTEGER { unknown (-1), gb2(2), gb4(4), gb8(8) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current negotiated data rate of fibre channel port."
::= { fcPortInfoEntry 5 }
fcPortConnModeNegotiated OBJECT-TYPE
SYNTAX INTEGER { unknown (-1), loop(1), ptp(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current negotiated mode of the fibre channel port."
::= { fcPortInfoEntry 6 }
fcPortDataRateConfigured OBJECT-TYPE
SYNTAX INTEGER { auto (-1), gb2(2), gb4(4), gb8(8) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Configured data rate of fibre channel port."
::= { fcPortInfoEntry 7 }
fcPortConnModeConfigured OBJECT-TYPE
SYNTAX INTEGER { loop(1), ptp(2), looppreferred(3), ptppreferred(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Configured mode of the fibre channel port."
::= { fcPortInfoEntry 8 }
fcPortDataRateCapability OBJECT-TYPE
SYNTAX INTEGER { gb2(2), gb4(4), gb8(8) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximum data rate capability of the fibre channel port. "
::= { fcPortInfoEntry 9 }
fcPortNodeName OBJECT-TYPE
SYNTAX DisplayWWN
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Fibre channel node name."
::= { fcPortInfoEntry 10 }
fcPortPortName OBJECT-TYPE
SYNTAX DisplayWWN
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Fibre channel port name."
::= { fcPortInfoEntry 11 }
fcPortPeerName OBJECT-TYPE
SYNTAX DisplayWWN
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The port name of the fabric-attached fibre channel peer.
Only valid for a switched fabric. Direct-connected fibre
channel ports will respond with all zeros."
::= { fcPortInfoEntry 12 }
--
-- fcPortStatistics Table
--
-- Most of the fc Port statistics are read-write. Writing a value to any
-- of the statistics counters will clear them all (set the counters to 0).
--
fcPortStatisticsEntry OBJECT-TYPE
SYNTAX FcPortStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores statistics about fibre channel ports."
INDEX { fcStatsIndex }
::= { fcPortStatisticsTable 1 }
FcPortStatisticsEntry ::= SEQUENCE {
fcStatsIndex Integer32,
fcStatsTxWords Unsigned32,
fcStatsRxWords Unsigned32,
fcStatsTimeSinceReset TimeInterval,
fcStatsErrLinkFailure Unsigned32,
fcStatsErrLossOfSync Unsigned32,
fcStatsErrInvalidCRC Unsigned32,
fcStatsErrInvalidTxWords Unsigned32,
fcStatsErrLipCount Unsigned32,
fcStatsErrNOSCount Unsigned32,
fcStatsErrSignalLoss Unsigned32,
fcStatsErrPrimitive Unsigned32
}
fcStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Used to index the fibre channel port in the Fibre Channel Port
Statistics table."
::= { fcPortStatisticsEntry 1 }
fcStatsTxWords OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Number of words transmitted on this fibre channel port."
::= { fcPortStatisticsEntry 2 }
fcStatsRxWords OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Number of words received on this fibre channel port."
::= { fcPortStatisticsEntry 3 }
fcStatsTimeSinceReset OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Amount of time since the fibre channel port statistics were
reset."
::= { fcPortStatisticsEntry 4 }
fcStatsErrLinkFailure OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Number of link failure events on this fibre channel port."
::= { fcPortStatisticsEntry 5 }
fcStatsErrLossOfSync OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of loss of sync events on this fibre channel port."
::= { fcPortStatisticsEntry 6 }
fcStatsErrInvalidCRC OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of frames with invalid CRCs on this fibre channel port."
::= { fcPortStatisticsEntry 7 }
fcStatsErrInvalidTxWords OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of invalid TX word events on this fibre channel port."
::= { fcPortStatisticsEntry 8 }
fcStatsErrLipCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of LIP events on this fibre channel port."
::= { fcPortStatisticsEntry 9 }
fcStatsErrNOSCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of NOS events on this fibre channel port."
::= { fcPortStatisticsEntry 10 }
fcStatsErrSignalLoss OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of loss of signal events on this fibre channel port."
::= { fcPortStatisticsEntry 11 }
fcStatsErrPrimitive OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of primitive sequential protocol errors on this
fibre channel port."
::= { fcPortStatisticsEntry 12 }
--
-- SasPortEntry table
--
sasPortInfoEntry OBJECT-TYPE
SYNTAX SASPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores information about the SAS ports."
INDEX { sasPortIndex }
::= { sasPortInfoTable 1}
SASPortInfoEntry ::= SEQUENCE {
sasPortIndex Integer32,
sasPortPortNumber Integer32,
sasPortOperationalState INTEGER,
sasPortPhy1State PHYStatus,
sasPortPhy2State PHYStatus,
sasPortPhy3State PHYStatus,
sasPortPhy4State PHYStatus,
sasPortAdminState INTEGER,
sasPortDataRateCapability INTEGER,
sasPortDataRateNegotiated INTEGER,
sasPortAddress DisplayWWN
}
sasPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Used to index the SAS port in the SAS Port Entry table."
::= { sasPortInfoEntry 1 }
sasPortPortNumber OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The SAS port number."
::= { sasPortInfoEntry 2 }
sasPortOperationalState OBJECT-TYPE
SYNTAX INTEGER { unknown (-1), online(1), offline(2), degraded(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Operational state of this entire SAS port. Degraded state is entered
when fewer than all four PHYs are online. Offline state is entered
when all four PHYs are offline."
::= { sasPortInfoEntry 3 }
sasPortPhy1State OBJECT-TYPE
SYNTAX PHYStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Operational state of SAS PHY 1 of this SAS port."
::= { sasPortInfoEntry 4 }
sasPortPhy2State OBJECT-TYPE
SYNTAX PHYStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Operational state of SAS PHY 2 of this SAS port."
::= { sasPortInfoEntry 5 }
sasPortPhy3State OBJECT-TYPE
SYNTAX PHYStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Operational state of SAS PHY 3 of this SAS port."
::= { sasPortInfoEntry 6 }
sasPortPhy4State OBJECT-TYPE
SYNTAX PHYStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Operational state of SAS PHY 4 of this SAS port."
::= { sasPortInfoEntry 7 }
sasPortAdminState OBJECT-TYPE
SYNTAX INTEGER { unknown (-1), disabled(1), enabled(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Administrative state of this SAS port.
Indicates whether the port is enabled or disabled."
::= { sasPortInfoEntry 8 }
sasPortDataRateCapability OBJECT-TYPE
SYNTAX INTEGER { gb1point5(1), gb3(3), gb6(6) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximum data rate capability of the SAS port."
::= { sasPortInfoEntry 9 }
sasPortDataRateNegotiated OBJECT-TYPE
SYNTAX INTEGER { gb1point5(1), gb3(3), gb6(6) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Current negotiated data rate of this SAS port."
::= { sasPortInfoEntry 10 }
sasPortAddress OBJECT-TYPE
SYNTAX DisplayWWN
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SAS Port Address."
::= { sasPortInfoEntry 11 }
--
-- sasPhyStatistics Table
--
-- Most of the sas phy statistics are read-write. Writing a value to any
-- of the statistics counters will clear them all (set the counters to 0).
--
sasPhyStatisticsEntry OBJECT-TYPE
SYNTAX SasPHYStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores statistics about SAS Phys."
INDEX { sasPhyStatsIndex }
::= { sasPhyStatisticsTable 1 }
SasPHYStatisticsEntry ::= SEQUENCE {
sasPhyStatsIndex Integer32,
sasPhyStatsTimeSinceReset TimeInterval,
sasPhyStatsErrLinkChanged Unsigned32,
sasPhyStatsErrInvalidCRC Unsigned32,
sasPhyStatsErrPhyReset Unsigned32,
sasPhyStatsErrLossOfSync Unsigned32,
sasPhyStatsErrDisparityCount Unsigned32,
sasPhyStatsErrInvalidDwords Unsigned32
}
sasPhyStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Used to index the SAS PHY in the SAS PHY Statistics table."
::= { sasPhyStatisticsEntry 1 }
sasPhyStatsTimeSinceReset OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Amount of time since the SAS PHY statistics were reset on this SAS PHY."
::= { sasPhyStatisticsEntry 2 }
sasPhyStatsErrLinkChanged OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of link changed events on this SAS PHY."
::= { sasPhyStatisticsEntry 3 }
sasPhyStatsErrInvalidCRC OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of Invalid CRC events on this SAS PHY."
::= { sasPhyStatisticsEntry 4 }
sasPhyStatsErrPhyReset OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of Phy Reset events on this SAS PHY."
::= { sasPhyStatisticsEntry 5 }
sasPhyStatsErrLossOfSync OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of loss of sync events on this SAS PHY."
::= { sasPhyStatisticsEntry 6}
sasPhyStatsErrDisparityCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of disparity error events on this SAS PHY."
::= { sasPhyStatisticsEntry 7 }
sasPhyStatsErrInvalidDwords OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Number of invalid DWORD events on this SAS PHY."
::= { sasPhyStatisticsEntry 8 }
--
--
-- Bridge Config
--
trapsEnabled OBJECT-TYPE
SYNTAX INTEGER { disabled(1), enabled(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether traps are enabled or disabled."
::= { bridgeConfig 1 }
snmpUpdatesEnabled OBJECT-TYPE
SYNTAX INTEGER { disabled(1), enabled(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether SNMP updates are enabled or disabled."
::= { bridgeConfig 2 }
-------------------------------------------------------------------------------
-- TRAP DEFINITIONS
-------------------------------------------------------------------------------
trapMaxClients OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum number of SNMP trap recipients supported by this
HW element."
::= { bridgeTrapInfo 1 }
--
-- Trap table definition
--
trapClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stores a row for each IP address/port number configured to receive traps."
::= { bridgeTrapInfo 2 }
trapClientEntry OBJECT-TYPE
SYNTAX TrapClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Ip/Port pair for a specific client."
INDEX { trapClientIndex }
::= { trapClientTable 1 }
TrapClientEntry ::= SEQUENCE {
trapClientIndex Integer32,
trapClientIpAddress DisplayString,
trapClientPort Integer32,
trapClientFilter INTEGER
}
trapClientIndex OBJECT-TYPE
SYNTAX Integer32 (0..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Used to index a trap client in the trapClientTable."
::= { trapClientEntry 1 }
trapClientIpAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of a client registered for traps in
dotted notation."
::= { trapClientEntry 2 }
trapClientPort OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The UDP port to send traps for this trap client. Normally this
would be the standard trap port (162). This object is an index
and must be specified to create a row in this table."
::= { trapClientEntry 3 }
trapClientFilter OBJECT-TYPE
SYNTAX INTEGER {
none (1),
critical (2),
warning (3),
informational (4),
all (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This value defines the trap severity filter for this trap
host. The unit will send traps to this trap client that
have a severity level less than or equal to this value.
The default value of this object is 'warning'."
::= { trapClientEntry 4 }
--
-- Bridge specific traps
--
bridgeTemperatureWarning NOTIFICATION-TYPE
OBJECTS { chassisTemperatureStatus, chassisTemperature }
STATUS current
DESCRIPTION "Supports notification of over/under temperature warnings.
The following information is returned:
tempStatus - the current temperature status
(normal, warning, critical)
Where normal indicates the temperature
is within the safe range. Warning indicates
the warning threshold has been reached.
Critical indicates that the temperature
is outside the safe range.
temperature - current temperature of the sensor
Recommended severity level (for filtering): warning"
::= { bridgeTraps 1 }
fcPortTransition NOTIFICATION-TYPE
OBJECTS { fcPortPortNumber, fcPortOperationalState }
STATUS current
DESCRIPTION "Supports notification of fibre channel port connectivity changes.
The following information is returned:
fcPortPortNumber - the description of the port
fcPortOperationalState - the current port state
Recommended severity level (for filtering): informational"
::= { bridgeTraps 2 }
sasPortTransition NOTIFICATION-TYPE
OBJECTS { sasPortPortNumber, sasPortOperationalState }
STATUS current
DESCRIPTION "Supports notification of SAS port connectivity changes.
The following information is returned:
sasPortPortNumber - the description of the port
sasPortOperationalState - the current port state
Recommended severity level (for filtering): informational"
::= { bridgeTraps 3 }
bridgeThroughputWarning NOTIFICATION-TYPE
OBJECTS { chassisThroughputStatus }
STATUS current
DESCRIPTION "Supports notification of max-throughput warning indicating a
potential data bottleneck. Data throughput is measured as aggregate
completed I/O's per second on the Fibre Channel interfaces.
The following information is returned:
ChassisthroughputStatus - the current throughput status
normal : no data bottleneck.
warning: aggregate fibre channel
throughput has exceeded 50,000 IOPS.
Recommended severity level (for filtering): informational"
::= { bridgeTraps 4 }
END