Observium_CE/mibs/arris/TI-PRODUCTION-MIB

905 lines
33 KiB
Plaintext

TI-PRODUCTION-MIB DEFINITIONS ::= BEGIN
IMPORTS
MacAddress,
DateAndTime,
DisplayString,
TruthValue
FROM SNMPv2-TC
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32,
Unsigned32,
IpAddress
FROM SNMPv2-SMI
eqName
FROM TI-MANUFACTURER-MIB
DocsisUpstreamType
FROM DOCS-IF-MIB;
modemProduction MODULE-IDENTITY
LAST-UPDATED "200805040000Z"
ORGANIZATION "TEXAS INSTRUMENTS"
CONTACT-INFO
"Igor Stadnik
Postal: TEXAS INSTRUMENTS
Hasadnaot 8, Herzlia 46766,
Israel. "
DESCRIPTION
" This is the private MIB module for the Puma5 Cable Modem Production"
::= { eqName 2 }
-- This MIB module contains the following groups.
modemProdCmSetup OBJECT IDENTIFIER ::= { modemProduction 1}
modemProdCmTest OBJECT IDENTIFIER ::= { modemProduction 2}
-- Production groups
modemProdCmPermanentSetup OBJECT IDENTIFIER ::= { modemProdCmSetup 1}
modemProdCmManufacturingSetup OBJECT IDENTIFIER ::= { modemProdCmSetup 2}
modemProdCmCalibrationSetup OBJECT IDENTIFIER ::= { modemProdCmSetup 3}
modemProdDownstreamCalibration OBJECT IDENTIFIER ::= { modemProdCmCalibrationSetup 1}
modemProdUpstreamTransmit OBJECT IDENTIFIER ::= { modemProdCmCalibrationSetup 2}
modemProdUpstreamCalibration OBJECT IDENTIFIER ::= { modemProdCmCalibrationSetup 3}
-- The access to all MIB objects is self-controlled by modemProdMibAccessControl
-- persistent object. It means that all MIB objects may be accessed in three
-- different access modes: maxaccess, limitedaccess and nonaccessible.
-- In nonaccessible mode the MIB will be unvisible. Objects are grouped to
-- support different behavior in limitedaccess mode. The group access may be
-- controlled by SNMP view.
--
-- maxaccess limited
-- modemProdCmPermanentSetup --------------------------------------
-- modemProdCmCertServerIp RW not-accessible
-- modemProdCmCertFileName RW not-accessible
-- modemProdCmCertKeyFileName RW not-accessible
-- modemProdCmCertFrequencyPlan RW not-accessible
-- modemProdCmCertDownload RW not-accessible
-- modemProdCmCertOperStat R not-accessible
-- modemProdCmManufacturingSetup ----------------------------------
-- modemProdMibAccessControl RW R
-- modemProdSerialNumber R R
-- modemProdMtaEnable RW R
-- modemProdMfgOrganizationName RW R
-- modemProdCvcAccessStart RW R
-- modemProdCodeAccessStart RW R
-- modemProdLanIp RW R
-- modemProdHostIp RW R
-- modemProdIpMask RW R
-- modemProdInterfaceName RW R
-- modemProdCmMacAddress RW R
-- modemProdLanMacAddress RW R
-- modemProdUsbDevMacAddress RW R
-- modemProdUsbHostMacAddress RW R
-- modemProdBaudRate RW R
-- modemProdTunersNumber RW R
-- modemProdDocsisPhyMultFact RW R
-- modemProdTunerType RW R
-- modemProdPgaType RW R
-- modemProdHwRevision RW R
-- modemProdFrequencyPlan RW R
-- modemProdCmCalibrationSetup ----------------------------------
-- modemProdDownstreamCalibration
-- modemProdDsCalibrationOperStatus R not-accessible
-- modemProdDsCalibrationAdminStatus RW not-accessible
-- modemProdPowerCalibrationTable ------------------------------
-- modemProdDsCallIndex not-accessible
-- modemProdDsFrequency RW not-accessible
-- modemProdDsPower RW not-accessible
-- modemProdUpstreamTransmit ----------------------------------
-- modemProdUpTransGain RW not-accessible
-- modemProdUpstreamTransmitTable ----------------------------------
-- modemProdUsTransmitlIndex not-accessible
-- modemProdUsFrequency RW not-accessible
-- modemProdUsModulation RW not-accessible
-- modemProdUsSymbolRate RW not-accessible
-- modemProdUsAttenuation RW not-accessible
-- modemProdUsTransmitionType RW not-accessible
-- modemProdUsBurst RW not-accessible
-- modemProdUpstreamCalibration ----------------------------------
-- modemProdUsCalibrationTableErase RW not-accessible
-- modemProdUsCalibrationModeFactor RW not-accessible
-- modemProdUsCalibrationPowerDelta RW not-accessible
-- modemProdUpstreamCalibrationTable ----------------------------------
-- modemProdUsCalibrationIndex not-accessible
-- modemProdUsCalibrationPower R not-accessible
-- modemProdFrequencyCalibrationTable ----------------------------------
-- modemProdUsFreqCalibrationIndex not-accessible
-- modemProdUsFreqCalibrationPower RW not-accessible
-- modemProdPgaAttenuationTable ----------------------------------
-- modemProdUsPgaAttenIndex not-accessible
-- modemProdUsPgaAttenPower RW not-accessible
-- modemProdCurrentModeFactorTable ----------------------------------
-- modemProdUsCmfIndex not-accessible
-- modemProdUsCmfPower RW not-accessible
-- modemProdUsCalibrationUpdateFlash RW not-accessible
-- modemProdCmPermanentSetup ----------------------------------------------
modemProdCmCertServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows and sets the certificate download server IP Address."
::= { modemProdCmPermanentSetup 1 }
modemProdCmCertFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows and sets the certificate filename."
::= { modemProdCmPermanentSetup 2 }
modemProdCmCertKeyFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows and sets the certificate key filename."
::= { modemProdCmPermanentSetup 3 }
modemProdCmCertFrequencyPlan OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
northAmerican(1),
european(2),
japanese(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows and sets the certificate frequency plan."
::= { modemProdCmPermanentSetup 4 }
modemProdCmCertDownload OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Initiates a certificate download for the selected bank.
All previously certificate download parameters must be predefined.
Always returns False(2), which does nothing."
::= { modemProdCmPermanentSetup 5 }
modemProdCmCertOperStat OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
downloadInProgress(1),
downloadSuccess(2),
downloadFailed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the SW operational process status."
::= { modemProdCmPermanentSetup 6 }
-- modemProdCmManufacturingSetup ----------------------------------------------
modemProdMibAccessControl OBJECT-TYPE
SYNTAX INTEGER {
maxaccess(1),
limitedaccess(2),
nonaccessible(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the SNMP access level for modemProduction Mibs.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 1}
modemProdSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the Serial Number.
The Serial Number is retrieved from serialDate and modemProdCmMacAddress.
MYXXXXXXXX when:
M: month = Jan(1), Feb(2), Mar(3), Apl(4), May(5), Jun(6),
Jul(7), Aug(8), Sep(9), Oct(X), Nov(Y), Dec(Z).
Y: year = 2001(1), 2002(2), 2009(9).
XXXXXXXX: Eight-digit decimal value of the last three bytes
of the CM MAC address.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 2 }
modemProdMtaEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable MTA feature flag.
Set to true(1) to enable MTA flag.
Set to false(2) to disable MTA flag.
The value of this object is stored in the NVRAM."
::= { modemProdCmManufacturingSetup 3 }
modemProdMfgOrganizationName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows the sets CM's MFG Organization Name.
The value of this object is stored in the NVRAM."
::= { modemProdCmManufacturingSetup 4 }
modemProdCvcAccessStart OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows the CVC Access Start Time into the CM.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 5 }
modemProdCodeAccessStart OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows the Code Access Start Time into the CM.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 6 }
modemProdLanIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows and sets the LAN IP Address.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 7 }
modemProdHostIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows and sets the Host IP Address.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 8 }
modemProdIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows and sets the Host IP Mask.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 9 }
modemProdInterfaceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows and sets interface Name.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 10 }
modemProdCmMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows the 48-bit Cable Modem MAC address.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 11 }
modemProdLanMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows the 48-bit Lan MAC address.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 12 }
modemProdUsbDevMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows the 48-bit USB device MAC address.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 13 }
modemProdUsbHostMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows the 48-bit USB host MAC address.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 14 }
modemProdBaudRate OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
br2400(1),
br4800(2),
br9600(3),
br19200(4),
br38400(5),
br115200(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows and sets the CM baud rate.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 15 }
modemProdTunersNumber OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows and sets the numbers of tuners.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 16 }
modemProdDocsisPhyMultFact OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows and sets the DOCSIS Phy Mult Fact.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 17 }
modemProdTunerType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
mt2060(1),
mt2064(2),
mt2068(3),
mt2170(4),
anadAt1061(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows and sets the CM tuner type.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 18 }
modemProdPgaType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
anadAra2017(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows and sets the CM PGA type.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 19 }
modemProdHwRevision OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows the boot HW major and minor revisions in the form XX.YY, where:
XX: two-digit decimal value of a major revision.
YY: two-digit decimal value of a minor revision.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 20 }
modemProdFrequencyPlan OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
northAmerican(1),
european(2),
japanese(3),
hybrid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows and sets the CM Frequency Plan.
The value of this object is stored into the NVRAM."
::= { modemProdCmManufacturingSetup 21 }
modemProdEnableCli OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the CLI on or off.
Setting to true(1) turns on CLI. Setting to false(2) turns
off CLI. The value is also stored into NV and will be
operational after next reboot. Returns current setting."
::= { modemProdCmManufacturingSetup 22 }
-- modemProdCmCalibrationSetup ----------------------------------
modemProdDsCalibrationOperStatus OBJECT-TYPE
SYNTAX INTEGER {
emptyTable(1),
completeTable(2),
callibrationInProgress(3),
callibrationComplete(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the status of calibration process. An empty value
is returned until all of the requested data is filled.
A ready value indicates that all of the requested data exists
and the CM is ready to start the calibration process."
::= { modemProdDownstreamCalibration 1 }
modemProdDsCalibrationAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
validateAndStart(1),
validateOnly(2),
startOnly(3),
erase(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Operate the downstream calibration table - validate data,
start calibration and erase table."
::= { modemProdDownstreamCalibration 2 }
-- modemProdPowerCalibrationTable ------------------------------
modemProdPowerCalibrationTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModemProdPowerCalibrationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object shows the downstream power calibration table.
The value of this object is stored into the NVRAM."
::= { modemProdDownstreamCalibration 3 }
modemProdPowerCalibrationEntry OBJECT-TYPE
SYNTAX ModemProdPowerCalibrationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains objects describing attributes of
one calibration frequncy and apropriate one calibration power.
An entry in this table exists for each index of frequency
and power vectors."
INDEX { modemProdDsCallIndex }
::= { modemProdPowerCalibrationTable 1 }
ModemProdPowerCalibrationEntry ::= SEQUENCE {
modemProdDsCallIndex INTEGER,
modemProdDsFrequency Integer32,
modemProdDsPower Integer32
}
modemProdDsCallIndex OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is index in frequency and power vectors."
::= { modemProdPowerCalibrationEntry 1 }
modemProdDsFrequency OBJECT-TYPE
SYNTAX Integer32 (80000..1300000)
UNITS "herz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object is frequency value into the vector."
::= { modemProdPowerCalibrationEntry 2 }
modemProdDsPower OBJECT-TYPE
SYNTAX Integer32 (-700..700)
UNITS "0.01 dbmV"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object is power value into the vector."
::= { modemProdPowerCalibrationEntry 3 }
-- modemProdUpstreamTransmit ----------------------------------
modemProdUpTransGain OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shows and sets Program US PGA gain value.
The value of this object is stored in the NVRAM."
::= { modemProdUpstreamTransmit 1 }
-- modemProdUpstreamTransmitTable ----------------------------------
modemProdUpstreamTransmitTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModemProdUpstreamTransmitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object shows the upstream transmit table.
The value of this object is stored into the NVRAM."
::= { modemProdUpstreamTransmit 2 }
modemProdUpstreamTransmitEntry OBJECT-TYPE
SYNTAX ModemProdUpstreamTransmitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains objects describing attributes for one
upstream channel.
An entry in this table exists for each upstream channel."
INDEX { modemProdUsTransmitlIndex }
::= { modemProdUpstreamTransmitTable 1 }
ModemProdUpstreamTransmitEntry ::= SEQUENCE {
modemProdUsTransmitlIndex INTEGER,
modemProdUsFrequency Integer32,
modemProdUsModulation INTEGER,
modemProdUsSymbolRate INTEGER,
modemProdUsAttenuation Integer32,
modemProdUsTransmitionType INTEGER,
modemProdUsBurst INTEGER
}
modemProdUsTransmitlIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is index represents Us channel."
::= { modemProdUpstreamTransmitEntry 1 }
modemProdUsFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "herz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set upstream to frequency for selected channel.
The value of this object is stored in the NVRAM."
::= { modemProdUpstreamTransmitEntry 2 }
modemProdUsModulation OBJECT-TYPE
SYNTAX INTEGER {
qpsk(1),
qam8(2),
qam16(3),
qam32(4),
qam64(5),
qam128(6),
qam256(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set upstream modulation for selected channel.
The value of this object is stored in the NVRAM."
::= { modemProdUpstreamTransmitEntry 3 }
modemProdUsSymbolRate OBJECT-TYPE
SYNTAX INTEGER {
sr1(1),
sr2(2),
sr4(3),
sr8(4),
sr16(5),
sr32(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set symbolRate*160Ksymb for selected channel.
The value of this object is stored in the NVRAM."
::= { modemProdUpstreamTransmitEntry 4 }
modemProdUsAttenuation OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set digital gain for selected channel.
The value of this object is stored in the NVRAM."
::= { modemProdUpstreamTransmitEntry 5 }
modemProdUsTransmitionType OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
data(2),
syn(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Program US cont for selected channel.
The value of this object is stored in the NVRAM."
::= { modemProdUpstreamTransmitEntry 6 }
modemProdUsBurst OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit US bursts for selected channel.
The value of this object is stored in the NVRAM."
::= { modemProdUpstreamTransmitEntry 7 }
-- modemProdUpstreamCalibration ----------------------------------
modemProdUsCalibrationTableErase OBJECT-TYPE
SYNTAX INTEGER {
pgaParams(1),
cmfParams(2),
freqParams(3),
allTables(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Erase one or all upstream calibration table."
::= { modemProdUpstreamCalibration 1 }
modemProdUsCalibrationModeFactor OBJECT-TYPE
SYNTAX INTEGER (1..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set upstream calibration current mode factor.
The value of this object is stored in the NVRAM."
::= { modemProdUpstreamCalibration 2 }
modemProdUsCalibrationPowerDelta OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set upstream calibration power delta.
The value of this object is stored in the NVRAM."
::= { modemProdUpstreamCalibration 3 }
-- modemProdUpstreamCalibrationTable ----------------------------------
modemProdUpstreamCalibrationTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModemProdUpstreamCalibrationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object shows the upstream calibration table.
The value of this object is stored into the NVRAM."
::= { modemProdUpstreamCalibration 4 }
modemProdUpstreamCalibrationEntry OBJECT-TYPE
SYNTAX ModemProdUpstreamCalibrationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains objects describing attributes for one
upstream channel.
An entry in this table exists for each upstream channel."
INDEX { modemProdUsCalibrationIndex }
::= { modemProdUpstreamCalibrationTable 1 }
ModemProdUpstreamCalibrationEntry ::= SEQUENCE {
modemProdUsCalibrationIndex INTEGER,
modemProdUsCalibrationPower Integer32
}
modemProdUsCalibrationIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is index represents Us channel."
::= { modemProdUpstreamCalibrationEntry 1 }
modemProdUsCalibrationPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Read reported power of selected channel.
The value of this object is stored in the NVRAM."
::= { modemProdUpstreamCalibrationEntry 2 }
-- modemProdFrequencyCalibrationTable ----------------------------------
modemProdFrequencyCalibrationTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModemProdFrequencyCalibrationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object shows the frecuency calibration table.
The value of this object is stored into the NVRAM."
::= { modemProdUpstreamCalibration 5 }
modemProdFrequencyCalibrationEntry OBJECT-TYPE
SYNTAX ModemProdFrequencyCalibrationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains objects describing attributes for Us
requency vector.
An entry in this table exists for each frequency."
INDEX { modemProdUsFreqCalibrationIndex }
::= { modemProdFrequencyCalibrationTable 1 }
ModemProdFrequencyCalibrationEntry ::= SEQUENCE {
modemProdUsFreqCalibrationIndex Integer32,
modemProdUsFreqCalibrationPower Integer32
}
modemProdUsFreqCalibrationIndex OBJECT-TYPE
SYNTAX Integer32
UNITS "herz"
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is index represents Us frequency.
The value of this object is stored in the NVRAM."
::= { modemProdFrequencyCalibrationEntry 1 }
modemProdUsFreqCalibrationPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBmV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Set power for frequency calibration value.
The value of this object is stored in the NVRAM."
::= { modemProdFrequencyCalibrationEntry 2 }
-- modemProdPgaAttenuationTable ----------------------------------
modemProdPgaAttenuationTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModemProdPgaAttenuationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object shows the PGA attenuation table.
The value of this object is stored into the NVRAM."
::= { modemProdUpstreamCalibration 6 }
modemProdPgaAttenuationEntry OBJECT-TYPE
SYNTAX ModemProdPgaAttenuationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains objects describing attributes for Us
PGA attenuation index."
INDEX { modemProdUsPgaAttenIndex }
::= { modemProdPgaAttenuationTable 1 }
ModemProdPgaAttenuationEntry ::= SEQUENCE {
modemProdUsPgaAttenIndex INTEGER,
modemProdUsPgaAttenPower Integer32
}
modemProdUsPgaAttenIndex OBJECT-TYPE
SYNTAX INTEGER {
pgaAtten0dB(1),
pgaAtten2dB(2),
pgaAtten4dB(3),
pgaAtten8dB(4),
pgaAtten16dB(5),
pgaAtten32dBb(6)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is index represents PGA attenuation.
The value of this object is stored in the NVRAM."
::= { modemProdPgaAttenuationEntry 1 }
modemProdUsPgaAttenPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBmV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Set power for PGA attenuation value.
The value of this object is stored in the NVRAM."
::= { modemProdPgaAttenuationEntry 2 }
-- modemProdCurrentModeFactorTable ----------------------------------
modemProdCurrentModeFactorTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModemProdCurrentModeFactorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object shows the current mode factor table.
The value of this object is stored into the NVRAM."
::= { modemProdUpstreamCalibration 7 }
modemProdCurrentModeFactorEntry OBJECT-TYPE
SYNTAX ModemProdCurrentModeFactorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains objects describing attributes for Us
current mode factor index."
INDEX { modemProdUsCmfIndex }
::= { modemProdCurrentModeFactorTable 1 }
ModemProdCurrentModeFactorEntry ::= SEQUENCE {
modemProdUsCmfIndex INTEGER,
modemProdUsCmfPower Integer32
}
modemProdUsCmfIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is index represents Current Mode Factor.
The value of this object is stored in the NVRAM."
::= { modemProdCurrentModeFactorEntry 1 }
modemProdUsCmfPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBmV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Set power for Current Mode Factor value.
The value of this object is stored in the NVRAM."
::= { modemProdCurrentModeFactorEntry 2 }
modemProdUsCalibrationUpdateFlash OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Update upstream calibration flash.
Always returns False(2), which does nothing."
::= { modemProdUpstreamCalibration 8 }
END