CADANT-CMTS-POLICY-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE,
MODULE-IDENTITY,
Integer32,
Unsigned32,
IpAddress,
Counter32,
Counter64
FROM SNMPv2-SMI
TruthValue,
RowStatus,
TimeStamp,
MacAddress,
TEXTUAL-CONVENTION
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
cadPolicy
FROM CADANT-PRODUCTS-MIB
CadExtAclCondition,
CadIfDirection,
CadIpTos,
CadIpTosMask,
CadTcpFlags,
CadAclType,
CadProtocolType,
CadAclString,
InetAddressIPv4or6
FROM CADANT-TC
InterfaceIndex
FROM IF-MIB
InetAddressType,
InetAddress
FROM INET-ADDRESS-MIB
InfoSourceDest
FROM DC-RTM-MIB;
cadPolicyMib MODULE-IDENTITY
LAST-UPDATED "201403260000Z" -- March 26, 2014
ORGANIZATION
"Arris International, Inc."
CONTACT-INFO
"Arris Technical Support
Postal: ARRIS
E-Mail: support@arrisi.com"
DESCRIPTION
"Arris Cadant C4 CMTS policy parameters and constants"
REVISION "201403260000Z" -- March 26, 2014
DESCRIPTION
"Use new default protocol type"
REVISION "201403060000Z" -- March 6, 2014
DESCRIPTION
"Remove cadAclMemorySize and cadAclMemoryRemaining"
REVISION "201305030000Z" -- May 3, 2013
DESCRIPTION
"Change index of cadPolicyPfxListEntry - Add cadPolicyPfxListAfi and
cadPolicyPfxListSafi as part of the index.
Change syntax of cadPolicyPfxListIpAddress from IpAddress to InetAddress
to support both ipv4 and ipv6."
REVISION "201304160000Z" -- April 16, 2013
DESCRIPTION
"Added the following new objects
cadRouteMapSetIpDscp, cadRouteMapIpDscp, cadRouteMapSetRecursiveNextHop,
and cadRouteMapRecursiveNextHop.
Change the range of the following objects from up to 2048 to 64
cadRouteMapId, cadRouteMapTagId, cadLocalPolicyRouteMap, and cadRouteMapClearStats"
REVISION "201112020000Z" -- Dec 2, 2011
DESCRIPTION
"Changed range for cadDistListOutAccessListNum from 1-999 to 0-999"
REVISION "201111080000Z" -- Nov 8, 2011
DESCRIPTION
"Added cadPolicyAccessGroupIpv6AclName and cadDistListOutAccessListName"
REVISION "201008260000Z" -- Aug 26, 2010
DESCRIPTION
"changed the syntax of cadRouteMapClearStats from TruthValue to Integer32"
REVISION "201008110000Z" -- Aug 11, 2010
DESCRIPTION
"changed the range of cadRouteMapTagId and cadRouteMapSeqNum."
REVISION "201007020000Z" -- July 2, 2010
DESCRIPTION
"Add support for policy based routing."
REVISION "201006020000Z"
DESCRIPTION
"Support IPv6 VR Index and IPv6 access numbers in CadDistListOut table."
REVISION "200909140000Z" -- Sep 14, 2009
DESCRIPTION
"change syntax of cadAclSrcIp, cadAclSrcIpMask, cadAclDstIp, cadAclDstIpMask to InetAddressIpv4orv6.
add cadAlvIpAddrType.
rename cadPolicyAccessGroupAclNum to cadPolicyAccessGroupIpv4ActNum
add cadPolicyAccessGroupIpv6AclNum
change syntax of cadAclOrderAclIndex from (1..199) to (1..399)"
REVISION "200803310000Z" -- March 31, 2008
DESCRIPTION
"Remove support for multiple SCM access ACLs"
REVISION "200803170000Z" -- March 17, 2008
DESCRIPTION
"Add support for ACL memory sizes."
REVISION "200704300000Z"
DESCRIPTION
"ACL support for RCM-based CMTS - remove the range of (1300..2699) in aclNumber."
REVISION "200608240000Z"
DESCRIPTION
"ACL support for RCM-based CMTS."
REVISION "200509090000Z"
DESCRIPTION
"Allow setting of cadAclType to remark."
REVISION "200508310000Z"
DESCRIPTION
"Add support for named ACLs and resequencing of ACLs."
REVISION "200506200000Z"
DESCRIPTION
"Allow arbitrary ACL indexes."
REVISION "200506100000Z"
DESCRIPTION
"Remove redundant access list configuration."
REVISION "200506060000Z"
DESCRIPTION
"Add set-fabric-priority-transmit for Multicast QoS for Arris Channel Bonding."
REVISION "200504140000Z"
DESCRIPTION
"Merge with 4.6."
REVISION "200503140000Z"
DESCRIPTION
"Add policy tables from old Netplane MIB."
REVISION "200411290000Z"
DESCRIPTION
"Swap the key order of src and dest protocol in cadDistListOutTable."
REVISION "200411180000Z"
DESCRIPTION
"Add support for network side data plane ACLs."
REVISION "200410260000Z"
DESCRIPTION
"Create table for output distribution lists."
REVISION "200409140000Z"
DESCRIPTION
"Add support for CAR rate limiting feature."
REVISION "200207090000Z"
DESCRIPTION
"Create table for input distribution lists."
REVISION "200205030000Z"
DESCRIPTION
"Create table for SCM access control policy."
::= { cadPolicy 1 }
--
-- Textual conventions used in policies
--
CadPolicyRateLimitAction ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enumeration of rate limiting actions"
SYNTAX INTEGER {
transmit(1),
drop(2),
set-prec-transmit(3),
set-dscp-transmit(4),
set-priority-transmit(5)
}
-- Derived variable types for Netplane policy
--
CadPolicyAction ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Action to be taken for Policy Policy Permit(1) Policy Deny (2) "
SYNTAX Integer32 (1..2)
CadPolicyProtocol ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A value that represents a type of the protocol."
SYNTAX INTEGER {
other (1), -- not specified
local (2), -- local interface
netmgmt (3), -- static route
icmp (4), -- result of ICMP Redirect
-- the following are all dynamic
-- routing protocols
egp (5), -- Exterior Gateway Protocol
ggp (6), -- Gateway-Gateway Protocol
hello (7), -- FuzzBall HelloSpeak
rip (8), -- Berkeley RIP or RIP-II
isIs (9), -- Dual IS-IS
esIs (10), -- ISO 9542
ciscoIgrp (11), -- Cisco IGRP
bbnSpfIgp (12), -- BBN SPF IGP
ospf (13), -- Open Shortest Path First
bgp (14), -- Border Gateway Protocol
idpr (15), -- InterDomain Policy Routing
ciscoEigrp (16) -- Cisco EIGRP
}
--
-- The SCM access table
--
cadScmAccessTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadScmAccessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table contains SCM access control list information.
Each physical interface is associated with the access list number defined
as hjpolAccListNumber in hjpolAccListTable of NETPLANE-POLICY-MIB. With
this information, C4 can permit/deny access usnig access list filtering before
the packet reach SCM from the specified physical interface."
::= { cadPolicyMib 1 }
cadScmAccessEntry OBJECT-TYPE
SYNTAX CadScmAccessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row containing information about SCM access list
for each physical interface."
INDEX { cadScmAccIfIndex }
::= { cadScmAccessTable 1 }
CadScmAccessEntry ::= SEQUENCE {
cadScmAccIfIndex InterfaceIndex,
cadScmAccListNumber Integer32,
cadScmAccRowStatus RowStatus
}
cadScmAccIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object identifies a physical layer2 interface, such as
a DOCSIS MAC or a Gigabit/TenGigabit NAM, on which SCM access control is applied"
::= { cadScmAccessEntry 1 }
cadScmAccListNumber OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies entry(or entries) in the
hjpolAccListTable. The identified entry(or entries)
contains SCM access parameters to be used when filtering
traffic from individual interface sent to SCM."
::= { cadScmAccessEntry 2 }
cadScmAccRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control Object for row creation and deletion."
::= { cadScmAccessEntry 3 }
--
-- The distribute-list in table
--
cadDistListInTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadDistListInEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Distribute List In Table"
REFERENCE
""
::= { cadPolicyMib 2 }
cadDistListInEntry OBJECT-TYPE
SYNTAX CadDistListInEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in Distribute List In table"
INDEX {
cadDistListInProtocol,
cadDistListInProtocolProcess,
cadDistListInIfIndex,
cadDistListInAccessListNum
}
::= { cadDistListInTable 1 }
CadDistListInEntry ::= SEQUENCE {
cadDistListInProtocol CadPolicyProtocol,
cadDistListInProtocolProcess Integer32,
cadDistListInIfIndex InterfaceIndex,
cadDistListInAccessListNum Integer32,
cadDistListInAccessListName OCTET STRING,
cadDistListInStatus RowStatus
}
cadDistListInProtocol OBJECT-TYPE
SYNTAX CadPolicyProtocol
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Protocol for which distribute list is applied."
::= { cadDistListInEntry 1 }
cadDistListInProtocolProcess OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VRF for which distribute list is applied."
::= { cadDistListInEntry 2 }
cadDistListInIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interface for which distribute list is applied. The value will be 1
if the distribute list is applied to all interfaces."
::= { cadDistListInEntry 3 }
cadDistListInAccessListNum OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configured distribute in list refers to the access list specified."
::= { cadDistListInEntry 4 }
cadDistListInAccessListName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Name of the access list referred by distribute in list."
::= { cadDistListInEntry 5 }
cadDistListInStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable, used according to row installation and
removal conventions. Once access list specified default row status
is active."
::= { cadDistListInEntry 6 }
--
-- CAR rate limiting
--
cadPolicyRateLimitTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadPolicyRateLimitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of rate limiting policies applied to a physical interface."
::= { cadPolicyMib 4 }
cadPolicyRateLimitEntry OBJECT-TYPE
SYNTAX CadPolicyRateLimitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An ordered list of the rate limit polices"
INDEX {
cadPolicyRateLimitIfIndex,
cadPolicyRateLimitDirection,
cadPolicyRateLimitIndex
}
::= { cadPolicyRateLimitTable 1 }
CadPolicyRateLimitEntry ::= SEQUENCE {
cadPolicyRateLimitIfIndex InterfaceIndex,
cadPolicyRateLimitDirection CadIfDirection,
cadPolicyRateLimitIndex INTEGER,
cadPolicyRateLimitStatus RowStatus,
cadPolicyRateLimitAclType CadAclType,
cadPolicyRateLimitAclNum Integer32,
cadPolicyRateLimitBps Integer32,
cadPolicyRateLimitBurstNormal Integer32,
cadPolicyRateLimitBurstMax Integer32,
cadPolicyRateLimitConformAction CadPolicyRateLimitAction,
cadPolicyRateLimitConformValue INTEGER,
cadPolicyRateLimitExceedAction CadPolicyRateLimitAction,
cadPolicyRateLimitExceedValue INTEGER,
cadPolicyRateLimitClearCounts TruthValue
}
cadPolicyRateLimitIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object identifies a physical layer2 interface, such as
a DOCSIS MAC or a Gigabit/TenGigabit NAM, on which the rate limit policy is applied"
::= { cadPolicyRateLimitEntry 1 }
cadPolicyRateLimitDirection OBJECT-TYPE
SYNTAX CadIfDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Direction of traffic on interface to apply the
rate limit policy"
::= { cadPolicyRateLimitEntry 2 }
cadPolicyRateLimitIndex OBJECT-TYPE
SYNTAX INTEGER(1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of rate limit policy. Policies are applied
in the order specified by this index value"
::= { cadPolicyRateLimitEntry 3 }
cadPolicyRateLimitStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Create and delete table row entries."
::= { cadPolicyRateLimitEntry 4 }
cadPolicyRateLimitAclType OBJECT-TYPE
SYNTAX CadAclType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Type of ACL associated with rate limit policy"
DEFVAL { none }
::= { cadPolicyRateLimitEntry 5 }
cadPolicyRateLimitAclNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ACL number. If the ACL does not exist, then this
is treated as if the ACL type is none, i.e. all
IP traffic matches the policy."
DEFVAL { 0 }
::= { cadPolicyRateLimitEntry 6 }
cadPolicyRateLimitBps OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Average rate, in bits per second (bps)."
DEFVAL { 0 }
::= { cadPolicyRateLimitEntry 7 }
cadPolicyRateLimitBurstNormal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Normal burst size, in bytes.
The minimum value is bps divided by 2000. "
DEFVAL { 0 }
::= { cadPolicyRateLimitEntry 8 }
cadPolicyRateLimitBurstMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Excess burst size, in bytes. Must be equal
to or larger than cadPolicyRateLimitBurstNormal"
DEFVAL { 0 }
::= { cadPolicyRateLimitEntry 9 }
cadPolicyRateLimitConformAction OBJECT-TYPE
SYNTAX CadPolicyRateLimitAction
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Action to take on packets that conform to the specified rate limit."
DEFVAL { transmit }
::= { cadPolicyRateLimitEntry 10 }
cadPolicyRateLimitConformValue OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Value to set if action is set-prec-transmit,
set-dscp-transmit or set-priority-transmit. For
set-priority-transmit,the valid value range is 0-7."
DEFVAL { 0 }
::= { cadPolicyRateLimitEntry 11 }
cadPolicyRateLimitExceedAction OBJECT-TYPE
SYNTAX CadPolicyRateLimitAction
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Action to take on packets that exceed to the specified rate limit."
DEFVAL { drop }
::= { cadPolicyRateLimitEntry 12 }
cadPolicyRateLimitExceedValue OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Value to set if action is set-prec-transmit,
set-dscp-transmit or set-priority-transmit. For
set-priority-transmit,the valid value range is 0-7."
DEFVAL { 0 }
::= { cadPolicyRateLimitEntry 13 }
cadPolicyRateLimitClearCounts OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If set to true, clear the counts in the CadPolicyRateLimitStatusEntry.
When read, this field always returns false. The correct way to clear
the counts is to first read them, then set ClearCounts to true."
DEFVAL { false }
::= { cadPolicyRateLimitEntry 14 }
--
-- Counts for rate limiting policy
--
cadPolicyRateLimitStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadPolicyRateLimitStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of counts of rate limiting policies
applied to a physical interface."
::= { cadPolicyMib 5 }
cadPolicyRateLimitStatusEntry OBJECT-TYPE
SYNTAX CadPolicyRateLimitStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Dyanmic status associated with a rate limit policy"
AUGMENTS { cadPolicyRateLimitEntry }
::= { cadPolicyRateLimitStatusTable 1 }
CadPolicyRateLimitStatusEntry ::= SEQUENCE {
cadPolicyRateLimitConformPackets Counter64,
cadPolicyRateLimitConformBytes Counter64,
cadPolicyRateLimitExceedPackets Counter64,
cadPolicyRateLimitExceedBytes Counter64,
cadPolicyRateLimitCurrentBurst Integer32,
cadPolicyRateLimitLastCleared TimeStamp
}
cadPolicyRateLimitConformPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets conforming to the policy rate"
::= { cadPolicyRateLimitStatusEntry 1 }
cadPolicyRateLimitConformBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes conforming to the policy rate"
::= { cadPolicyRateLimitStatusEntry 2 }
cadPolicyRateLimitExceedPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets exceeding to the policy rate"
::= { cadPolicyRateLimitStatusEntry 3 }
cadPolicyRateLimitExceedBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes exceeding to the policy rate"
::= { cadPolicyRateLimitStatusEntry 4 }
cadPolicyRateLimitCurrentBurst OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of bytes in the burst exceeding the average bps rate"
::= { cadPolicyRateLimitStatusEntry 5 }
cadPolicyRateLimitLastCleared OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of SysUptime when the rate limit counters were last cleared."
::= { cadPolicyRateLimitStatusEntry 6 }
--
-- Global ACL support
--
cadPolicyAclTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadPolicyAclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table contains access control list (ACL) information.
Each row corresponds to an access control entry (ACE),
and each ACL may have multiple ACEs that are applied
in order to the packet being inspected."
::= { cadPolicyMib 6 }
cadPolicyAclEntry OBJECT-TYPE
SYNTAX CadPolicyAclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row containing information about SCM access list
for each physical interface."
INDEX { cadAclNumber, cadAclIndex }
::= { cadPolicyAclTable 1 }
CadPolicyAclEntry ::= SEQUENCE {
cadAclNumber Integer32,
cadAclIndex Integer32,
cadAclType CadAclType,
cadAclStatus RowStatus,
cadAclPermit TruthValue,
cadAclProtocol CadProtocolType,
cadAclSrcIp InetAddressIPv4or6,
cadAclSrcIpMask InetAddressIPv4or6,
cadAclSrcPortOp CadExtAclCondition,
cadAclSrcPortLo Integer32,
cadAclSrcPortHi Integer32,
cadAclDstIp InetAddressIPv4or6,
cadAclDstIpMask InetAddressIPv4or6,
cadAclDstPortOp CadExtAclCondition,
cadAclDstPortLo Integer32,
cadAclDstPortHi Integer32,
cadAclProtoType Integer32,
cadAclLogging TruthValue,
cadAclProtoCode Integer32,
cadAclIpTos CadIpTos,
cadAclIpTosMask CadIpTosMask,
cadAclTcpFlags CadTcpFlags,
cadAclTcpFlagsMask CadTcpFlags,
cadAclFragments TruthValue,
cadAclRemark CadAclString,
cadAclIpAddrType InetAddressType
}
cadAclNumber OBJECT-TYPE
SYNTAX Integer32 (1..399)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IPv6 ACL number. IPv6 ACLs are in the range 200-399.
Extended ACL number. Extended ACLs are in the range 100-199.
Standard ACLs are in the range 1-99."
::= { cadPolicyAclEntry 1 }
cadAclIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Order in which this ACE is used in the ACL."
::= { cadPolicyAclEntry 2 }
cadAclType OBJECT-TYPE
SYNTAX CadAclType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether this EACE is used as a standard,
extended, or remark ACL. The rate-limiting type is
not valid for this table. Remark is the only valid
type that can be set, standard and extended are set
by the agent when the ACE is created."
::= { cadPolicyAclEntry 3 }
cadAclStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus used to add and remove ACEs. ACEs that contain
only remarks should have their status set to notInService
and should be created with createAndWait."
::= { cadPolicyAclEntry 4 }
cadAclPermit OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Permit or Deny the packet when matched."
DEFVAL { false }
::= { cadPolicyAclEntry 5 }
cadAclProtocol OBJECT-TYPE
SYNTAX CadProtocolType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Protocol number to match"
DEFVAL { -1 } -- not used
::= { cadPolicyAclEntry 6 }
cadAclSrcIp OBJECT-TYPE
SYNTAX InetAddressIPv4or6
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source IP address to match"
DEFVAL { '00000000'h }
::= { cadPolicyAclEntry 7 }
cadAclSrcIpMask OBJECT-TYPE
SYNTAX InetAddressIPv4or6
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source IP wildcard mask to match. Default to match anything"
DEFVAL { 'FFFFFFFF'h }
::= { cadPolicyAclEntry 8 }
cadAclSrcPortOp OBJECT-TYPE
SYNTAX CadExtAclCondition
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source port condition (lt,gt,eq,ne) to match."
DEFVAL { na }
::= { cadPolicyAclEntry 9 }
cadAclSrcPortLo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"First Source port number to match. -1 indicates that this
field is not used."
DEFVAL { -1 }
::= { cadPolicyAclEntry 10 }
cadAclSrcPortHi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Second Source port number to match. -1 indicates that this
field is not used."
DEFVAL { -1 }
::= { cadPolicyAclEntry 11 }
cadAclDstIp OBJECT-TYPE
SYNTAX InetAddressIPv4or6
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination IP address to match"
DEFVAL { '00000000'h }
::= { cadPolicyAclEntry 12 }
cadAclDstIpMask OBJECT-TYPE
SYNTAX InetAddressIPv4or6
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination IP wildcard (inverse) mask to match.
Default to match anything."
DEFVAL { 'FFFFFFFF'h }
::= { cadPolicyAclEntry 13 }
cadAclDstPortOp OBJECT-TYPE
SYNTAX CadExtAclCondition
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination port condition (lt,gt,eq,ne) to match."
DEFVAL { na }
::= { cadPolicyAclEntry 14 }
cadAclDstPortLo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"First Destination port number to match. -1 indicates that
this field is not used."
DEFVAL { -1 }
::= { cadPolicyAclEntry 15 }
cadAclDstPortHi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Second Destination port number to match. -1 indicates that
this field is not used"
DEFVAL { -1 }
::= { cadPolicyAclEntry 16 }
cadAclLogging OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Turn on or off the ACE matching log"
DEFVAL { false }
::= { cadPolicyAclEntry 17 }
cadAclProtoType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Sub-protocol qualifiers. For protocol type ICMP, this value
matches the ICMP message type (0 - 255). For IGMP, this
value matches the IGMP message type (0-15). A value of -1
means that this field is not used."
DEFVAL { -1 }
::= { cadPolicyAclEntry 18 }
cadAclProtoCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Sub-protocol qualifiers. For protocol type ICMP, this value
matches the ICMP message type code (0 - 255). A value of -1
indicates this value is not used."
DEFVAL { -1 }
::= { cadPolicyAclEntry 19 }
cadAclIpTos OBJECT-TYPE
SYNTAX CadIpTos
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Matches the TOS field of the IP header."
DEFVAL { 0 }
::= { cadPolicyAclEntry 20 }
cadAclIpTosMask OBJECT-TYPE
SYNTAX CadIpTosMask
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Mask to apply to the IpTos object when finding a mactch
on the TOS field of the IP header. A value of 0 is used
to indicate that the TOS is not used."
DEFVAL { 0 }
::= { cadPolicyAclEntry 21 }
cadAclTcpFlags OBJECT-TYPE
SYNTAX CadTcpFlags
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Matches the flags field of the TCP header."
DEFVAL { {} }
::= { cadPolicyAclEntry 22 }
cadAclTcpFlagsMask OBJECT-TYPE
SYNTAX CadTcpFlags
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Mask to apply to the TcpFlags object when finding a mactch
on the flags field of the TCP header."
DEFVAL { {} }
::= { cadPolicyAclEntry 23 }
cadAclFragments OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether this EACE applies to noninitial fragments
of packets. The default is disabled."
DEFVAL { false }
::= { cadPolicyAclEntry 24 }
cadAclRemark OBJECT-TYPE
SYNTAX CadAclString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The comment associated with the access control entry.
This is only valid for ACEs of type remark."
DEFVAL { ''h }
::= { cadPolicyAclEntry 26 }
cadAclIpAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP Address type"
DEFVAL { ipv4 }
::= { cadPolicyAclEntry 27 }
--
-- The SNMP Community-String Access table
--
cadSnmpCommAccessTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSnmpCommAccessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table contains the access list information associated with the
community string. Each community string defined in snmpCommunithTable
can be configured with one access list number. C4 can permit/deny access
usnig access list filtering. Filtering will occur in software, after
the SNMP traffic passed through the OSE protocol stack and received by
the agent. Standard ACLs will be used to enforce the access restrictions"
::= { cadPolicyMib 7 }
cadSnmpCommAccessEntry OBJECT-TYPE
SYNTAX CadSnmpCommAccessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row containing information about access list filtering
associated with community string."
INDEX { IMPLIED cadSnmpCommAccessName }
::= { cadSnmpCommAccessTable 1 }
CadSnmpCommAccessEntry ::= SEQUENCE {
cadSnmpCommAccessName SnmpAdminString,
cadSnmpCommAccessList Integer32,
cadSnmpCommAccessStatus RowStatus
}
cadSnmpCommAccessName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index value that uniquely identifies an entry in snmpCommunityTable."
::= { cadSnmpCommAccessEntry 1 }
cadSnmpCommAccessList OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies entry (or entries) in the
cadPolicyAclTable. The identified entry (or entries) contains
access parameters to be used when filtering traffic sent to SNMP agent."
DEFVAL { 1 }
::= { cadSnmpCommAccessEntry 2 }
cadSnmpCommAccessStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Control Object for row creation and deletion."
::= { cadSnmpCommAccessEntry 3 }
--
-- Interface Access Group
--
cadPolicyAccessGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadPolicyAccessGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of access group policies applied to a physical interface."
::= { cadPolicyMib 8 }
cadPolicyAccessGroupEntry OBJECT-TYPE
SYNTAX CadPolicyAccessGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An ordered list of the access group polices"
INDEX { cadPolicyAccessGroupIfIndex, cadPolicyAccessGroupDirection }
::= { cadPolicyAccessGroupTable 1 }
CadPolicyAccessGroupEntry ::= SEQUENCE {
cadPolicyAccessGroupIfIndex InterfaceIndex,
cadPolicyAccessGroupDirection CadIfDirection,
cadPolicyAccessGroupStatus RowStatus,
cadPolicyAccessGroupIpv4AclNum Integer32,
cadPolicyAccessGroupClearCounts TruthValue,
cadPolicyAccessGroupIpv6AclNum Integer32,
cadPolicyAccessGroupIpv6AclName SnmpAdminString
}
cadPolicyAccessGroupIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object identifies a physical layer2 interface, such as
a DOCSIS MAC or a Gigabit/TenGigabit NAM, on which the access group policy is applied"
::= { cadPolicyAccessGroupEntry 1 }
cadPolicyAccessGroupDirection OBJECT-TYPE
SYNTAX CadIfDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Direction of traffic on interface to apply the access
group policy"
::= { cadPolicyAccessGroupEntry 2 }
cadPolicyAccessGroupStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This table supports sets of createAndGo(4) and destroy(6)"
::= { cadPolicyAccessGroupEntry 3 }
cadPolicyAccessGroupIpv4AclNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ACL number. If the ACL does not exist, then this
is treated as if the ACL type is none, i.e. all
IPv4 traffic matches the policy."
DEFVAL { 0 }
::= { cadPolicyAccessGroupEntry 4 }
cadPolicyAccessGroupClearCounts OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If set to true, clear the counts in the CadPolicyAccessGroupStatusEntry.
When read, this field always returns false. The correct way to clear
the counts is to first read them, then set ClearCounts to true."
DEFVAL { false }
::= { cadPolicyAccessGroupEntry 5 }
cadPolicyAccessGroupIpv6AclNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ACL number. If the ACL does not exist, then this
is treated as if the ACL type is none, i.e. all
IPv6 traffic matches the policy."
DEFVAL { 0 }
::= { cadPolicyAccessGroupEntry 6 }
cadPolicyAccessGroupIpv6AclName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ACL name."
DEFVAL { "" }
::= { cadPolicyAccessGroupEntry 7 }
--
-- Counts for access group policy
--
cadPolicyAccessGroupStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadPolicyAccessGroupStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of counts of rate limiting policies
applied to a physical interface."
::= { cadPolicyMib 9 }
cadPolicyAccessGroupStatusEntry OBJECT-TYPE
SYNTAX CadPolicyAccessGroupStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Dyanmic status associated with a rate limit policy"
AUGMENTS { cadPolicyAccessGroupEntry }
::= { cadPolicyAccessGroupStatusTable 1 }
CadPolicyAccessGroupStatusEntry ::= SEQUENCE {
cadPolicyAccessGroupPermitPackets Counter64,
cadPolicyAccessGroupDenyPackets Counter64,
cadPolicyAccessGroupLastCleared TimeStamp
}
cadPolicyAccessGroupPermitPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets conforming to the access group policy permit ACL"
::= { cadPolicyAccessGroupStatusEntry 1 }
cadPolicyAccessGroupDenyPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets conforming to the access group policy deny ACL"
::= { cadPolicyAccessGroupStatusEntry 2 }
cadPolicyAccessGroupLastCleared OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of SysUptime when the access group policy counters
were last cleared."
::= { cadPolicyAccessGroupStatusEntry 3 }
--
-- prefix-list configuration
--
cadPolicyPfxListTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadPolicyPfxListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Prefix List Table"
REFERENCE
""
::= { cadPolicyMib 11 }
cadPolicyPfxListEntry OBJECT-TYPE
SYNTAX CadPolicyPfxListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in Prefix list table"
INDEX {
cadPolicyPfxListNumber,
cadPolicyPfxListName,
cadPolicyPfxListSeqNumber,
cadPolicyPfxListAfi,
cadPolicyPfxListSafi,
cadPolicyPfxListIpAddress,
cadPolicyPfxListIpAddMaskLen,
cadPolicyPfxListMaskGeValue,
cadPolicyPfxListMaskLeValue
}
::= { cadPolicyPfxListTable 1 }
CadPolicyPfxListEntry ::= SEQUENCE {
cadPolicyPfxListNumber Integer32,
cadPolicyPfxListName OCTET STRING,
cadPolicyPfxListSeqNumber Integer32,
cadPolicyPfxListIpAddress InetAddress,
cadPolicyPfxListIpAddMaskLen Integer32,
cadPolicyPfxListMaskGeValue Integer32,
cadPolicyPfxListMaskLeValue Integer32,
cadPolicyPfxListAction CadPolicyAction,
cadPolicyPfxListStatus RowStatus,
cadPolicyPfxListAfi InetAddressType,
cadPolicyPfxListSafi INTEGER
}
cadPolicyPfxListNumber OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Prefix list is identified by number
value of 0 should be passed for this object if prefix list
is configured by name"
::= { cadPolicyPfxListEntry 1 }
cadPolicyPfxListName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of prefix list.Null value is assigned to this
Object if the prefix list is identified by number"
::= { cadPolicyPfxListEntry 2 }
cadPolicyPfxListSeqNumber OBJECT-TYPE
SYNTAX Integer32 (5..2147483645)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A sequence in the prefix list is identified by sequence number.
If no sequence is specified defalut sequence of 5 is assumend. IF
one more sequence is configured sequence number 10 is assigned
(multiples of 5)"
::= { cadPolicyPfxListEntry 3 }
cadPolicyPfxListIpAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the source ipv4 or ipv6 address on which the
filtering needs to be applied"
::= { cadPolicyPfxListEntry 4 }
cadPolicyPfxListIpAddMaskLen OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mask length of the Source IP address"
::= { cadPolicyPfxListEntry 5 }
cadPolicyPfxListMaskGeValue OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the received route matches the source address
and the mask length is greater than the value specified,
apply the specified action to the route"
::= { cadPolicyPfxListEntry 6 }
cadPolicyPfxListMaskLeValue OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value specifies if the received route mask length is less
the value specified here do the action specified (permit/deny)"
::= { cadPolicyPfxListEntry 7 }
cadPolicyPfxListAction OBJECT-TYPE
SYNTAX CadPolicyAction
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"specifies the action to be taken. Possible actions
include permit(1) and deny(2) "
::= { cadPolicyPfxListEntry 8 }
cadPolicyPfxListStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable, used according to
row installation and removal conventions."
::= { cadPolicyPfxListEntry 9 }
cadPolicyPfxListAfi OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the Address Family Identifier (AFI) of the prefix
that will follow. Only IPv4 or IPv6 prefix-list will be supported."
::= { cadPolicyPfxListEntry 10 }
cadPolicyPfxListSafi OBJECT-TYPE
SYNTAX INTEGER {
unicast(1),
multicast(2),
both(3),
mplsBgpVpn(128)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the Subsequent Address Family Identifier (SAFI)
of the prefix that will follow."
::= { cadPolicyPfxListEntry 11 }
-- Distribute list in configuration
-- Distribute List is used to specify filtering
cadPolicyDistListOutTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadPolicyDistListOutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Distribute List Out Table"
REFERENCE
""
::= { cadPolicyMib 12 }
cadPolicyDistListOutEntry OBJECT-TYPE
SYNTAX CadPolicyDistListOutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in Distribute List Out table"
INDEX {
cadPolicyDistListOutSrcProtocol,
cadPolicyDistListOutSrcProtocolProcess,
cadPolicyDistListOutRoutingProtocol,
cadPolicyDistListOutRoutingProcess,
cadPolicyDistListOutAutonomousSystemNum,
cadPolicyDistListOutIfIndex,
cadPolicyDistListOutAccessListNum
}
::= { cadPolicyDistListOutTable 1 }
CadPolicyDistListOutEntry ::= SEQUENCE {
cadPolicyDistListOutSrcProtocol CadPolicyProtocol,
cadPolicyDistListOutSrcProtocolProcess Integer32,
cadPolicyDistListOutRoutingProtocol CadPolicyProtocol,
cadPolicyDistListOutRoutingProcess Integer32,
cadPolicyDistListOutAutonomousSystemNum Integer32,
cadPolicyDistListOutAccessListNum Integer32,
cadPolicyDistListOutAccessListName OCTET STRING,
cadPolicyDistListOutStatus RowStatus,
cadPolicyDistListOutIfIndex InterfaceIndex
}
cadPolicyDistListOutSrcProtocol OBJECT-TYPE
SYNTAX CadPolicyProtocol
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Source Protocol under which distribute list is configured."
::= { cadPolicyDistListOutEntry 1 }
cadPolicyDistListOutSrcProtocolProcess OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Source VRF ID under which distribute list is configured."
::= { cadPolicyDistListOutEntry 2 }
cadPolicyDistListOutRoutingProtocol OBJECT-TYPE
SYNTAX CadPolicyProtocol
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Destination Protocol to which routes need to be sent."
::= { cadPolicyDistListOutEntry 3 }
cadPolicyDistListOutRoutingProcess OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Destination VRF ID under which distribute list is configured."
::= { cadPolicyDistListOutEntry 4 }
cadPolicyDistListOutAutonomousSystemNum OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Autonomous system number of BGP to which routes need to be
redistributed. If destination protocol is BGP appropriate AS
number needs to be filled for this object. Otherwise set a
value of 1 for this object."
::= { cadPolicyDistListOutEntry 5 }
cadPolicyDistListOutAccessListNum OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configured distribute out list refers to the access list
specified. The access list number must be in the range of 1 - 99"
::= { cadPolicyDistListOutEntry 6 }
cadPolicyDistListOutAccessListName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Name of the access list referred by distribute list. The
access list name must be less than 32 characters"
::= { cadPolicyDistListOutEntry 7 }
cadPolicyDistListOutStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable, used according to row installation and
removal conventions. Once access list specified default row status
is UP."
::= { cadPolicyDistListOutEntry 8 }
cadPolicyDistListOutIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interface for which distribute list is applied. The value will be 1
if the distribute list is applied to all interfaces."
::= { cadPolicyDistListOutEntry 9 }
--
-- The distribute-list out table
--
cadDistListOutTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadDistListOutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Distribute List Out Table"
REFERENCE
""
::= { cadPolicyMib 13 }
cadDistListOutEntry OBJECT-TYPE
SYNTAX CadDistListOutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in Distribute List Out table"
INDEX {
cadDistListOutVrIndex,
cadDistListOutDestProtocol,
cadDistListOutSrcProtocol
}
::= { cadDistListOutTable 1 }
CadDistListOutEntry ::= SEQUENCE {
cadDistListOutVrIndex Integer32,
cadDistListOutDestProtocol InfoSourceDest,
cadDistListOutSrcProtocol InfoSourceDest,
cadDistListOutAccessListNum Integer32,
cadDistListOutStatus RowStatus,
cadDistListOutAccessListName SnmpAdminString
}
cadDistListOutVrIndex OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"virtual router index"
::= { cadDistListOutEntry 1 }
cadDistListOutDestProtocol OBJECT-TYPE
SYNTAX InfoSourceDest
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Destination protocol for which distribute list is applied."
::= { cadDistListOutEntry 2 }
cadDistListOutSrcProtocol OBJECT-TYPE
SYNTAX InfoSourceDest
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Source protocol for which distribute list is applied."
::= { cadDistListOutEntry 3 }
cadDistListOutAccessListNum OBJECT-TYPE
SYNTAX Integer32 (0..999)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Access List Number"
::= { cadDistListOutEntry 4 }
cadDistListOutStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable, used according to row installation and
removal conventions. Once access list specified default row status
is active."
::= { cadDistListOutEntry 5 }
cadDistListOutAccessListName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Access List Name"
DEFVAL { "" }
::= { cadDistListOutEntry 6 }
--
-- The ACL name table
--
cadAclNameTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadAclNameEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table maps names to ACL entries.
Each row associates a name with the indexed ACL."
::= { cadPolicyMib 14 }
cadAclNameEntry OBJECT-TYPE
SYNTAX CadAclNameEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row containing name information about an ACL."
INDEX { cadNameAclName, cadNameAclNumber }
::= { cadAclNameTable 1 }
CadAclNameEntry ::= SEQUENCE {
cadNameAclName SnmpAdminString,
cadNameAclNumber Integer32,
cadNameAclStatus RowStatus
}
cadNameAclName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The name of the access control list."
::= { cadAclNameEntry 1 }
cadNameAclNumber OBJECT-TYPE
SYNTAX Integer32 (1..399)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Extended ACL number. Extended ACLs are in the range 100-199.
Standard ACLs are in the range 1-99."
::= { cadAclNameEntry 2 }
cadNameAclStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus used to add and remove names for ACLs. When an ACL
is removed, the associated name is also removed."
::= { cadAclNameEntry 3 }
--
-- ACL Control
--
-- This group contains control variables for the ACL policy tables.
--
cadAclControl OBJECT IDENTIFIER ::= { cadPolicyMib 15 }
cadAclOrderAcl OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable always returns false(2) upon reading. When
set to true(1), the ACL identified in cadAclOrderAclIndex
is renumbered with interval cadAclOrderAclInterval."
DEFVAL { false }
::= { cadAclControl 1 }
cadAclOrderAclIndex OBJECT-TYPE
SYNTAX INTEGER(1..399)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable identifies the ACL that should be renumbered."
DEFVAL { 1 }
::= { cadAclControl 2 }
cadAclOrderAclInterval OBJECT-TYPE
SYNTAX INTEGER(1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable specifies the numbering interval used between
each ACE when reordering an ACL."
DEFVAL { 10 }
::= { cadAclControl 3 }
cadAclOrderAclStart OBJECT-TYPE
SYNTAX INTEGER(1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable specifies the index that ACL reordering
will use as the base for the first ACE."
DEFVAL { 10 }
::= { cadAclControl 4 }
cadAclClearIpv4AclCounts OBJECT-TYPE
SYNTAX Integer32(0..199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable specifies the access list number for which
all IPv4 per-entry counts will be cleared.
This number may correspond to an individual access list (1..199).
Setting to '0' will cause the per-entry counts to be cleared for ALL
IPv4 configured access lists.
This variable always returns '0' upon reading"
DEFVAL { 0 }
::= { cadAclControl 5 }
cadAclClearIpv6AclCounts OBJECT-TYPE
SYNTAX Integer32(0 | 200..399)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable specifies the access list number for which
all IPv6 per-entry counts will be cleared.
This number may correspond to an individual access list (200..399).
Setting to '0' will cause the per-entry counts to be cleared for ALL
IPv6 configured access lists.
This variable always returns '0' upon reading"
DEFVAL { 0 }
::= { cadAclControl 6 }
cadPolicyAclExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadPolicyAclExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The cadPolicyAclExtTable augments the cadPolicyAclTable with
a count for total number of times the access list
entry has been matched by all referencing applications."
::= { cadPolicyMib 16 }
cadPolicyAclExtEntry OBJECT-TYPE
SYNTAX CadPolicyAclExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about the policy access list entry."
AUGMENTS { cadPolicyAclEntry }
::= { cadPolicyAclExtTable 1 }
CadPolicyAclExtEntry ::= SEQUENCE {
cadAclEntryCount Counter64
}
cadAclEntryCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of times the access list entry has been matched by all
referencing applications."
::= { cadPolicyAclExtEntry 1 }
--
-- ACL memory sizes
--
-- cadAclMemory OBJECT IDENTIFIER ::= { cadPolicyMib 20 }
--
-- Policy Based Routing
--
cadPolicyRouting OBJECT IDENTIFIER ::= { cadPolicyMib 30 }
--
-- Mapping of Route Map Names to Route Map Ids
--
cadRouteMapTagTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadRouteMapTagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table maps policy route map names to route map entries.
Each row associates a name with the indexed policy route map."
::= { cadPolicyRouting 1 }
cadRouteMapTagEntry OBJECT-TYPE
SYNTAX CadRouteMapTagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row containing name information for a policy route map."
INDEX { cadRouteMapTagName }
::= { cadRouteMapTagTable 1 }
CadRouteMapTagEntry ::= SEQUENCE {
cadRouteMapTagName SnmpAdminString,
cadRouteMapTagId Integer32,
cadRouteMapTagRowStatus RowStatus
}
cadRouteMapTagName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(1..64))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Name to used for this policy route map"
::= { cadRouteMapTagEntry 1 }
cadRouteMapTagId OBJECT-TYPE
SYNTAX Integer32(1..64)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Id used to associate entries in the policy route map table to this name."
::= { cadRouteMapTagEntry 2 }
cadRouteMapTagRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable used according to row installation
and removal convention. In our case, we have simplified this
to the usage of only the following states - active, createAndGo,
and destroy. Other three states notInService, notReady and
createAndWait are not permitted."
::= { cadRouteMapTagEntry 3 }
--
-- Route Map Match table
--
cadRouteMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadRouteMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains policy route map data where each row
contains information about the ACL being used and what
set operations should be applied to the IP packet on a match."
::= { cadPolicyRouting 2 }
cadRouteMapEntry OBJECT-TYPE
SYNTAX CadRouteMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row containing information for a policy route map entry."
INDEX { cadRouteMapId, cadRouteMapSeqNum }
::= { cadRouteMapTable 1 }
CadRouteMapEntry ::= SEQUENCE {
cadRouteMapId Integer32,
cadRouteMapSeqNum Integer32,
cadRouteMapMatchType INTEGER,
cadRouteMapMatchAcl Integer32,
cadRouteMapSetIpPrec TruthValue,
cadRouteMapIpPrec INTEGER,
cadRouteMapSetIpTos TruthValue,
cadRouteMapIpTos INTEGER,
cadRouteMapSetNextHop TruthValue,
cadRouteMapNextHopAddrType InetAddressType,
cadRouteMapNextHop InetAddress,
cadRouteMapSetBackupNextHop TruthValue,
cadRouteMapBackupNextHop InetAddress,
cadRouteMapSetNullInterface TruthValue,
cadRouteMapRowStatus RowStatus,
cadRouteMapSetIpDscp TruthValue,
cadRouteMapIpDscp INTEGER,
cadRouteMapSetRecursiveNextHop TruthValue,
cadRouteMapRecursiveNextHop InetAddress
}
cadRouteMapId OBJECT-TYPE
SYNTAX Integer32(1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Id used to associate entries in the policy route map table."
::= { cadRouteMapEntry 1 }
cadRouteMapSeqNum OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sequence number used to order the match statements."
::= { cadRouteMapEntry 2 }
cadRouteMapMatchType OBJECT-TYPE
SYNTAX INTEGER {
permit(1),
deny(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Type of match to used for this entry. Permit matches
on the provided ACL and then applies the defined set operations
before destination routing. Deny matches on the provided
ACL and then directly routes to the destination without applying
any of the set critera to the packet."
::= { cadRouteMapEntry 3 }
cadRouteMapMatchAcl OBJECT-TYPE
SYNTAX Integer32 (0..199)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ACL used to match the incoming packet. Since IPv4 is the only supported
address type, the ACL number must be an extended or standard ACL. A value 0
implies that no ACL is used and all packets will match this entry."
::= { cadRouteMapEntry 4 }
cadRouteMapSetIpPrec OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the IP Precedence should be changed on the packet
if it matches the ACL and this is a permit type of match."
DEFVAL { false }
::= { cadRouteMapEntry 5 }
cadRouteMapIpPrec OBJECT-TYPE
SYNTAX INTEGER {
routine(0),
priority(1),
immediate(2),
flash(3),
flash-override(4),
critical(5),
internet(6),
network(7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP precedence value that should be used to replace the
existing IP precedence of the matching packet."
DEFVAL { routine }
::= { cadRouteMapEntry 6 }
cadRouteMapSetIpTos OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the IP TOS should be changed on the packet
if it matches the ACL and this is a permit type of match."
DEFVAL { false }
::= { cadRouteMapEntry 7 }
cadRouteMapIpTos OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
min-monetary-cost(1),
max-reliability(2),
max-throughput(4),
min-delay(8)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP TOS value that should be used to replace the
existing IP TOS of the matching packet."
DEFVAL { normal }
::= { cadRouteMapEntry 8 }
cadRouteMapSetNextHop OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the next hop setting should be used to specify
the adjacent next hop router when forwarding the matching packet."
DEFVAL { false }
::= { cadRouteMapEntry 9 }
cadRouteMapNextHopAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The address type of the next hop and backup next hop addresses.
Currently IPv4 is the only supported address type."
DEFVAL { ipv4 }
::= { cadRouteMapEntry 10 }
cadRouteMapNextHop OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The address of the adjacent next hop router to use in forwading
the matching packet. The next hop router address must be the
address of an ajacent router, and the routing table (VRF?) is
used to verify that the address can be directly reached. Only IPv4
addresses are currently supported."
DEFVAL { ''H }
::= { cadRouteMapEntry 11 }
cadRouteMapSetBackupNextHop OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the backup next hop setting should be used to specify
the adjacent next hop router when forwarding the matching packet. This
only would be done if the primary next hop was not set or was unreachable."
DEFVAL { false }
::= { cadRouteMapEntry 12 }
cadRouteMapBackupNextHop OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The address type of a second next hop, that can be used only
if the primary next hop address can not be reached. Only Ipv4
addresses are currently supported."
DEFVAL { ''H }
::= { cadRouteMapEntry 13 }
cadRouteMapSetNullInterface OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If set to true and the packet matches the ACL, it will be dropped."
DEFVAL { false }
::= { cadRouteMapEntry 14 }
cadRouteMapRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable used according to row installation
and removal convention. In our case, we have simplified this
to the usage of only the following states - active, createAndGo,
and destroy. Other three states notInService, notReady and
createAndWait are not permitted."
::= { cadRouteMapEntry 15 }
cadRouteMapSetIpDscp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the IP DSCP should be changed on the packet
if it matches the ACL and this is a permit type of match."
DEFVAL { false }
::= { cadRouteMapEntry 16 }
cadRouteMapIpDscp OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP DSCP value that should be used to replace the
existing IP DSCP of the matching packet."
DEFVAL { 0 }
::= { cadRouteMapEntry 17 }
cadRouteMapSetRecursiveNextHop OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the recursive next hop setting should be used to specify
the next hop for the remote router when forwarding the matching packet."
DEFVAL { false }
::= { cadRouteMapEntry 18 }
cadRouteMapRecursiveNextHop OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The address type of a remote router next hop, that is used to perform a recursive
route lookup. Only Ipv4 addresses are currently supported."
DEFVAL { ''H }
::= { cadRouteMapEntry 19 }
--
-- Route Map Stats table
--
cadRouteMapStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadRouteMapStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains policy route map counts where each row
contains information about the number of packets that match
the specified ACL and were successfully changed with the defined
set operations, as well as those that matched the ACL but failed
the set operations."
::= { cadPolicyRouting 3 }
cadRouteMapStatsEntry OBJECT-TYPE
SYNTAX CadRouteMapStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row containing counts information for a policy route map entry."
INDEX { cadRouteMapId, cadRouteMapSeqNum }
::= { cadRouteMapStatsTable 1 }
CadRouteMapStatsEntry ::= SEQUENCE {
cadRouteMapPktMatched Counter32,
cadRouteMapByteMatched Counter64,
cadRouteMapPktFailed Counter32,
cadRouteMapByteFailed Counter64
}
cadRouteMapPktMatched OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets that match the ACL defined in the route map entry
and where the action was also successful. For matches of type deny, the
packet is routed by destination, and for packets of type match, the packet
is successfully modified and sent."
::= { cadRouteMapStatsEntry 1 }
cadRouteMapByteMatched OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes that match the ACL defined in the route map entry
and where the action was also successful. For matches of type deny, the
packet is routed by destination, and for packets of type match, the packet
is successfully modified and sent."
::= { cadRouteMapStatsEntry 2 }
cadRouteMapPktFailed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets that match the ACL defined in the route map entry
and where the action failed. For route map entries of type match, the
set operation failed."
::= { cadRouteMapStatsEntry 3 }
cadRouteMapByteFailed OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets that match the ACL defined in the route map entry
and where the action failed. For route map entries of type match, the
set operation failed."
::= { cadRouteMapStatsEntry 4 }
--
-- Stats control
--
cadRouteMapClearStats OBJECT-TYPE
SYNTAX Integer32(0..64)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this value will reset all the byte and packet counts for a
route map. A value of 0 indicates no reset is performed."
DEFVAL { 0 }
::= { cadPolicyRouting 4 }
--
-- Local policy routing
--
cadLocalPolicyRouteMap OBJECT-TYPE
SYNTAX Integer32 (0..64)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value contains the mapId of the policy route map to be used
for local policy based routing. A value of 0 indicates no local
policy routing is performed."
DEFVAL { 0 }
::= { cadPolicyRouting 5 }
END -- End of CADANT-CMTS-POLICY-MIB