2750 lines
102 KiB
Plaintext
2750 lines
102 KiB
Plaintext
-- Copyright (C) 2008-2012 Aricent Group . All Rights Reserved
|
|
|
|
-- $Id: fsqosxtd.mib,v 1.25 2016/07/05 07:38:42 siva Exp $
|
|
|
|
-- ========================================================================== --
|
|
-- DIFF SERVER DATA PATH FLOW --
|
|
-- ========================================================================== --
|
|
--
|
|
-- +==========+ +========+ +==========+
|
|
-- Traffic | | | | +==========+ InProf | |
|
|
-- | | | | | |( green,| |
|
|
-- | Classify | | Pre | | | yellow)| Marking, |
|
|
-- ========>| |===>| Marking|===>| Metering |=======>| |
|
|
-- | | | | +====+=====+ +==>| |
|
|
-- +==========+ +========+ | | +==========+
|
|
-- | | |
|
|
-- OutProfile=====+ |
|
|
-- (red) (soft police) |
|
|
-- | |
|
|
-- | |
|
|
-- | |
|
|
-- (hard police) |
|
|
-- | |
|
|
-- +==========+ |
|
|
-- | pkt drop | |
|
|
-- +==========+ |
|
|
-- |
|
|
-- |
|
|
-- +===============+ +===============+ |
|
|
-- Tx to egress port| |<=====| Queueing / | |
|
|
-- <=============== | Scheduling/ | | Shaping |======+
|
|
-- | Rate-Shaping | | |
|
|
-- +===============+ +===============+
|
|
|
|
-- ========================================================================== --
|
|
|
|
ARICENT-QOS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Unsigned32, MODULE-IDENTITY, OBJECT-TYPE, enterprises, Integer32,
|
|
Counter64 FROM SNMPv2-SMI
|
|
ifIndex FROM IF-MIB
|
|
TEXTUAL-CONVENTION, RowStatus, DisplayString, TruthValue FROM SNMPv2-TC;
|
|
|
|
fsQoSMib MODULE-IDENTITY
|
|
LAST-UPDATED "201209050000Z"
|
|
ORGANIZATION "ARICENT COMMUNICATIONS SOFTWARE"
|
|
CONTACT-INFO "support@aricent.com"
|
|
DESCRIPTION
|
|
"This MIB defines the objects necessary to manage
|
|
a device that uses the Differentiated Services."
|
|
REVISION "201209050000Z"
|
|
DESCRIPTION
|
|
"This MIB defines the objects necessary to manage
|
|
a device that uses the Differentiated Services."
|
|
|
|
::= { enterprises aricent-communication-holding-ltd(29601) iss(2) 6}
|
|
|
|
Dscp ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Differentiated Services Code-Point that may be used for
|
|
marking a traffic stream."
|
|
REFERENCE
|
|
"RFC 2474, RFC 2780"
|
|
SYNTAX Integer32 (0..63)
|
|
|
|
MeterColorMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enums to indicate the color mode of the Meter
|
|
colorAware - the Meter will also consider the Pre-Color
|
|
of the Packet
|
|
colorBlind - the Meter will ignore the Pre-Color of the Packet"
|
|
SYNTAX INTEGER {
|
|
colorAware(1),
|
|
colorBlind(2)
|
|
}
|
|
|
|
MeterType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enums to indicate the meter type :
|
|
SimpleTokenBucket - Two Parameter Token Bucket Meter as described in
|
|
the Informal Differentiated Services Model section
|
|
5.2.3.
|
|
AvgRate - Average Rate Meter as described in the Informal
|
|
Differentiated Services Model section 5.2.1.
|
|
SrTCM - Single Rate Three Color Marker Metering as defined
|
|
by RFC 2697.
|
|
TrTCM - Two Rate Three Color Marker Metering as defined by
|
|
RFC 2698.
|
|
TswTCM - Time Sliding Window Three Color Marker Metering as
|
|
defined by RFC 2859.
|
|
mefDecoupledMeter - Dual bucket meter as defined by RFC 4115.
|
|
mefCoupledMeter - Dual bucket meter as defined by RFC 2697 and
|
|
MEF coupling Flag."
|
|
SYNTAX INTEGER {
|
|
simpleTokenBucket(1),
|
|
avgRate(2),
|
|
srTCM(3),
|
|
trTCM(4),
|
|
tswTCM(5),
|
|
mefDecoupledMeter(6),
|
|
mefCoupledMeter(7)
|
|
}
|
|
|
|
EnableStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "A textual convention to Enable or Disable a MIB contruct."
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
|
|
SchedulerPriority ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Scheduler Priority which a flow should fall in."
|
|
SYNTAX Integer32 (0..15)
|
|
|
|
IndexInteger ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer which may be used as a table index. If 0 then it is invalid"
|
|
SYNTAX Unsigned32 (0..65535)
|
|
|
|
-- ========================================================================== --
|
|
-- groups in the MIB --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSMIBObjects OBJECT IDENTIFIER ::= { fsQoSMib 1 }
|
|
|
|
-- System Object to support system specific scalars.
|
|
fsQoSSystem OBJECT IDENTIFIER ::= { fsQoSMIBObjects 1 }
|
|
|
|
-- Class Table
|
|
fsQoSClass OBJECT IDENTIFIER ::= { fsQoSMIBObjects 2 }
|
|
|
|
-- Policy Table : Meter and Action tables
|
|
fsQoSPolicy OBJECT IDENTIFIER ::= { fsQoSMIBObjects 3 }
|
|
|
|
-- Traffic Management Tables for shaping , managing queues and scheduling them
|
|
fsQoSTrafficMgmt OBJECT IDENTIFIER ::= { fsQoSMIBObjects 4 }
|
|
|
|
-- Stats
|
|
fsQoSStats OBJECT IDENTIFIER ::= { fsQoSMIBObjects 5 }
|
|
|
|
-- Rate Control Table : For CPU port
|
|
fsQosHwCpuRateControl OBJECT IDENTIFIER ::= { fsQoSMIBObjects 6 }
|
|
|
|
fsQoSSystemControl OBJECT-TYPE
|
|
SYNTAX INTEGER { shutdown(0), start(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Starts or shutdowns QoS Module in the system.
|
|
When set as 'start',resources required by QoS module are
|
|
allocated & QoS module starts running.
|
|
When shutdown, all the pools used by QoS module will be
|
|
released to the system."
|
|
::= { fsQoSSystem 1 }
|
|
|
|
fsQoSStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables or Disables QoS Module in the system.
|
|
When set as 'enabled', QoS module programs the hardware
|
|
and starts Protocol Operation.
|
|
When set as 'disabled', it stops protocol operation by
|
|
deleting the hardware configuration.
|
|
If any mib table supports global configurations (less-specific)
|
|
at runtime and H/W supports more-specific configurations,
|
|
then appropriate behaviour may take effect in H/W only after next
|
|
status change of this object."
|
|
DEFVAL { enabled }
|
|
::= { fsQoSSystem 2 }
|
|
|
|
fsQoSTrcFlag OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to enable trace statements in QoS module.
|
|
A four byte integer is used for enabling the trace level.
|
|
Each bit in the four byte integer represents a particular
|
|
trace level.
|
|
The mapping between the bit positions & the trace level is
|
|
as follows:
|
|
0 - Init and Shutdown traces
|
|
1 - Management traces
|
|
2 - Data Path traces
|
|
3 - Control Plane traces
|
|
5 - Traces related to all resources except buffers
|
|
6 - Buffer allocation/release traces
|
|
7 - All Failure traces
|
|
None of the bit is set the Disable the Trace,value(0).
|
|
|
|
The remaining bits are unused. Combination of levels are
|
|
also allowed.
|
|
|
|
For example if the bits 0 and 1 are set, then the trace
|
|
statement related to Init-Shutdown and management
|
|
will be printed.
|
|
|
|
The user has to enter the corresponding integer value for the
|
|
bits set. For example if bits 0 and 1 are to be set ,then user
|
|
has to give the value 3."
|
|
::= { fsQoSSystem 3 }
|
|
|
|
fsQoSRateUnit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
bps(1),
|
|
kbps(2),
|
|
mbps(3),
|
|
gbps(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This Object indicates the unit for the
|
|
Information Rate(CIR,EIR,PIR,PTR,CTR ...)values
|
|
based on target platform.
|
|
This Object specifies the unit alone. Value corresponding
|
|
to this unit should be taken from 'fsQoSRateGranularity'
|
|
Ex 1:
|
|
'fsQoSRateUnit' = kbps
|
|
'fsQoSRateGranularity' = 64
|
|
then this target will accept the Information
|
|
Rate(CIR,EIR,TIR,PTR, CTR ...) values in multiples of 64
|
|
like 64 kbps, 128 kbps ...
|
|
Ex 2:
|
|
'fsQoSRateUnit' = mbps
|
|
'fsQoSRateGranularity' = 64
|
|
then this target will accept the Information
|
|
Rate(CIR,EIR,TIR,PTR, CTR ...) values in multiples of 64
|
|
like 64 mbps, 128 mbps ..."
|
|
|
|
::= { fsQoSSystem 4 }
|
|
|
|
fsQoSRateGranularity OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This Object indicates the acceptable Granularity level
|
|
for configuring the Information Rate(CIR,EIR,PIR,PTR,
|
|
CTR ...)values for a target platform.
|
|
This Object specifies the Integer Value for the
|
|
granularity. Unit for
|
|
this value should be taken from 'fsQoSRateUnit'
|
|
Ex 1:
|
|
'fsQoSRateUnit' = kbps
|
|
'fsQoSRateGranularity' = 64
|
|
then this target will accept the Information
|
|
Rate(CIR,EIR,TIR,PTR, CTR ...) values in multiples of 64
|
|
like 64 kbps, 128 kbps ...
|
|
Ex 2:
|
|
'fsQoSRateUnit' = mbps
|
|
'fsQoSRateGranularity' = 64
|
|
then this target will accept the Information
|
|
Rate(CIR,EIR,TIR,PTR, CTR ...) values in multiples of 64
|
|
like 64 mbps, 128 mbps ..."
|
|
::= { fsQoSSystem 5 }
|
|
|
|
-- ========================================================================== --
|
|
-- Priority Map Table --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSPriorityMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSPriorityMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table to map incoming priority to a regenerated priority.
|
|
This table is used to regenerate port/VLAN priorities for an
|
|
incoming packet. It can be used to directly program priority
|
|
tables in the hardware."
|
|
::= { fsQoSClass 1 }
|
|
|
|
fsQoSPriorityMapEntry OBJECT-TYPE
|
|
SYNTAX FsQoSPriorityMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry to map an incoming priority, drop-precedence to a
|
|
regenerated priority value for an ingress PORT/VLAN. The PORT/VLAN
|
|
indices may take dont-care (0) values as required."
|
|
INDEX { fsQoSPriorityMapID }
|
|
::= { fsQoSPriorityMapTable 1 }
|
|
|
|
FsQoSPriorityMapEntry ::=
|
|
SEQUENCE {
|
|
fsQoSPriorityMapID IndexInteger,
|
|
fsQoSPriorityMapName DisplayString,
|
|
fsQoSPriorityMapIfIndex Unsigned32,
|
|
fsQoSPriorityMapVlanId Unsigned32,
|
|
fsQoSPriorityMapInPriority Integer32,
|
|
fsQoSPriorityMapInPriType INTEGER,
|
|
fsQoSPriorityMapRegenPriority Unsigned32,
|
|
fsQoSPriorityMapRegenInnerPriority Unsigned32,
|
|
fsQoSPriorityMapConfigStatus INTEGER,
|
|
fsQoSPriorityMapStatus RowStatus,
|
|
fsQoSPriorityMapInDEI INTEGER,
|
|
fsQoSPriorityMapRegenColor INTEGER
|
|
}
|
|
|
|
fsQoSPriorityMapID OBJECT-TYPE
|
|
SYNTAX IndexInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The output priority map index for the incoming packet received over
|
|
ingress PORT/VLAN with specified incoming priority. This is unique for
|
|
each entry in the priority-map table."
|
|
::= { fsQoSPriorityMapEntry 1 }
|
|
|
|
|
|
fsQoSPriorityMapName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the Name for the Priority map entry.
|
|
It should be unique in this Table."
|
|
::= { fsQoSPriorityMapEntry 2 }
|
|
|
|
fsQoSPriorityMapIfIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Incoming Port Number. The PORT may take dont-care (0) values
|
|
as required."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPriorityMapEntry 3 }
|
|
|
|
fsQoSPriorityMapVlanId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Vlan Id for Priority regeneration.The VlanId may
|
|
take dont-care (0) values as required."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPriorityMapEntry 4 }
|
|
|
|
fsQoSPriorityMapInPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The incoming Priority value determined for the received frame.
|
|
This value is equivalent to the priority( VLAN (4 bit)/DSCP( 6 bit)
|
|
priority bits) indicated in the received frame, or one of the
|
|
evaluated priorities."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPriorityMapEntry 5 }
|
|
|
|
fsQoSPriorityMapInPriType OBJECT-TYPE
|
|
SYNTAX INTEGER { vlanPri(0),
|
|
ipTos(1),
|
|
ipDscp(2),
|
|
mplsExp(3),
|
|
vlanDEI(4),
|
|
dot1P(5)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Incoming Priority Type is used to Identify the
|
|
'fsQoSPriorityMapInPriority' value is a vlanPri or IP TOS or IP DSCP
|
|
or MPLS EXP or dot1P. If the incoming Priority type is 802.1P, the incoming
|
|
packet priority and drop_eligible can be supported. If incoming DEI
|
|
'fsQoSPriorityMapInDEI' is not set by the administrator, the
|
|
drop_eligible bit is set as 0 by default."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPriorityMapEntry 6 }
|
|
|
|
fsQoSPriorityMapRegenPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Regenerated Priority value determined for the received frame."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPriorityMapEntry 7 }
|
|
|
|
fsQoSPriorityMapRegenInnerPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Regenerated Inner-VLAN (CVLAN) Priority value determined
|
|
for the received frame. It the Values is 8 then this object is not
|
|
configured by user"
|
|
::= { fsQoSPriorityMapEntry 8 }
|
|
|
|
fsQoSPriorityMapConfigStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sysdefault(1),
|
|
management(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the prority map entry. Indicates whether
|
|
entry is configured by management or is a default entry."
|
|
DEFVAL { sysdefault }
|
|
::= { fsQoSPriorityMapEntry 9 }
|
|
|
|
fsQoSPriorityMapStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. All writable objects in this
|
|
row may be modified at any time.
|
|
It can be deleted 'destroy', only if it is not referenced
|
|
by other table; otherwise returns inconsistentValue error.
|
|
For any mib table that supports global configurations (less-specific) at runtime
|
|
and H/W supports more-specific configurations, if a more-specific entry is deleted
|
|
by configuration, then the next less-specific entry gets programmed to H/W"
|
|
::= { fsQoSPriorityMapEntry 10 }
|
|
|
|
fsQoSPriorityMapInDEI OBJECT-TYPE
|
|
SYNTAX INTEGER { false(0),
|
|
true(1)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Drop_eligible bit in the incoming frames.
|
|
Either it can take false(0) or true (1). By default, drop_eligible bit is
|
|
not set."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPriorityMapEntry 11 }
|
|
|
|
fsQoSPriorityMapRegenColor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
green(0), -- Traffic conforms to SLAs
|
|
yellow(1), -- Traffic exceeds the SLAs
|
|
red (2) -- Traffic violates the SLAs
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the regenerated color determined for the received frame."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPriorityMapEntry 12 }
|
|
|
|
-- ========================================================================== --
|
|
-- MultiField ClassMap Table --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSClassMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSClassMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the Multifield Classifier details. It takes input
|
|
from the ACL or priority-map table and outputs a CLASS for the
|
|
traffic-class pattern/match."
|
|
::= { fsQoSClass 2 }
|
|
|
|
fsQoSClassMapEntry OBJECT-TYPE
|
|
SYNTAX FsQoSClassMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Multi-field Classifier entry maps an ACL entry or a priority-map
|
|
to a CLASS of Service."
|
|
INDEX { fsQoSClassMapId }
|
|
::= { fsQoSClassMapTable 1 }
|
|
|
|
-- This table outputs a CLASS for the input FilterId/Priority-MAP.
|
|
FsQoSClassMapEntry ::= SEQUENCE {
|
|
fsQoSClassMapId IndexInteger,
|
|
fsQoSClassMapName DisplayString,
|
|
-- input ACL/Priority-Map ID
|
|
fsQoSClassMapL2FilterId Unsigned32,
|
|
fsQoSClassMapL3FilterId Unsigned32,
|
|
fsQoSClassMapPriorityMapId Unsigned32,
|
|
-- outputs
|
|
fsQoSClassMapCLASS Unsigned32,
|
|
fsQoSClassMapClfrId Unsigned32,
|
|
fsQoSClassMapPreColor INTEGER, -- Color b4 Meter
|
|
fsQoSClassMapStatus RowStatus,
|
|
fsQoSClassMapVlanMapId Unsigned32
|
|
}
|
|
|
|
fsQoSClassMapId OBJECT-TYPE
|
|
SYNTAX IndexInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that enumerates the MultiField Classifier table."
|
|
::= { fsQoSClassMapEntry 1 }
|
|
|
|
fsQoSClassMapName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the Name for the Entry.Multiple ACL/priority-map
|
|
entries can map to the same CLASS. They need to be configured with
|
|
the same ClassMapName."
|
|
::= { fsQoSClassMapEntry 2 }
|
|
|
|
fsQoSClassMapL2FilterId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object specifies the ID of the MAC filter, the details of which
|
|
should be matched against the incoming packet. A valid value of this
|
|
object is not mandatory for the creation of the conceptual row. However,
|
|
L2/L3 FilterId is mutually exclusive to the Priority-Map Id. One
|
|
of them is a mandatory input for an entry."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSClassMapEntry 3 }
|
|
|
|
fsQoSClassMapL3FilterId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object specifies the ID of the IP filter, the details of which
|
|
should be matched against the incoming packet. A valid value of this
|
|
object is not mandatory for the creation of the conceptual row. However,
|
|
L2/L3 FilterId is mutually exclusive to the Priority-Map Id. One
|
|
of them is a mandatory input for an entry."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSClassMapEntry 4 }
|
|
|
|
fsQoSClassMapPriorityMapId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object specifies the priority map ID for mapping incoming priority
|
|
against received packet.A valid value of this
|
|
object is not mandatory for the creation of the conceptual row. However,
|
|
L2/L3 FilterId is mutually exclusive to the Priority-Map Id. One
|
|
of them is a mandatory input for an entry."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSClassMapEntry 5 }
|
|
|
|
fsQoSClassMapCLASS OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the Traffic CLASS to which an incoming frame pattern
|
|
is classified. The administrator needs to define the logical groups
|
|
that represent this CLASS. Multiple ACL/priority-map entries can
|
|
map to the same CLASS value. '0' is not configurable but it is the
|
|
default value."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSClassMapEntry 6 }
|
|
|
|
fsQoSClassMapClfrId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the Classifier Id of teh Classifier in the Standard Qos Entry.
|
|
This used to get the datapath entry pointing to teh CLass-Map with respect to the
|
|
Standard MIB"
|
|
DEFVAL { 0 }
|
|
::= { fsQoSClassMapEntry 7 }
|
|
|
|
|
|
fsQoSClassMapPreColor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (0), -- Traffic is not pre-colored
|
|
green(1), -- Traffic conforms to SLAs
|
|
yellow(2), -- Traffic exceeds the SLAs
|
|
red (3) -- Traffic violates the SLAs
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the color of the packet prior to metering.
|
|
The default Drop-Precedence for the packet can be evaluated
|
|
using this object. This value is overridden by the meter."
|
|
::= { fsQoSClassMapEntry 8 }
|
|
|
|
fsQoSClassMapVlanMapId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the VLAN Map ID for mapping an incoming VLAN
|
|
to an Egress Subscriber Queue. Filter ID/ Priority-Map Id are mutually
|
|
exclusive to the Vlan Map Id. One of them is a mandatory input for a
|
|
class-map entry."
|
|
::= { fsQoSClassMapEntry 9 }
|
|
|
|
|
|
fsQoSClassMapStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. All writable objects in this
|
|
row may be modified only when the row status is not active.
|
|
CreateAndGo not allowed ,it can be deleted 'destroy',
|
|
only if it is not referenced
|
|
by other table; otherwise return inconsistentValue error."
|
|
::= { fsQoSClassMapEntry 10 }
|
|
|
|
-- ========================================================================== --
|
|
-- ClassToPriority Table --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSClassToPriorityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSClassToPriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table assigns local priority values for a input CLASS. This table
|
|
is optional and can be configured as per user requirement. This table
|
|
is provided for easy mapping of CLASS to priority values.
|
|
A set of non-contiguous CLASS values belong to a
|
|
unique Group ( identified by a group name)."
|
|
::= { fsQoSClass 3 }
|
|
|
|
fsQoSClassToPriorityEntry OBJECT-TYPE
|
|
SYNTAX FsQoSClassToPriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry to specify a regenerated priority value for a input CLASS."
|
|
INDEX { fsQoSClassToPriorityCLASS }
|
|
::= { fsQoSClassToPriorityTable 1 }
|
|
|
|
-- This table maps a CLASS to a regenerated priority value.
|
|
FsQoSClassToPriorityEntry ::= SEQUENCE {
|
|
fsQoSClassToPriorityCLASS IndexInteger,
|
|
fsQoSClassToPriorityRegenPri Unsigned32,
|
|
fsQoSClassToPriorityGroupName DisplayString,
|
|
fsQoSClassToPriorityStatus RowStatus
|
|
}
|
|
|
|
fsQoSClassToPriorityCLASS OBJECT-TYPE
|
|
SYNTAX IndexInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the Traffic CLASS to which an incoming frame pattern
|
|
is classified. The administrator needs to define the traffic
|
|
class patterns that represent this CLASS. Multiple
|
|
ACL/priority-map entries can map to the same CLASS value."
|
|
::= { fsQoSClassToPriorityEntry 1 }
|
|
|
|
fsQoSClassToPriorityRegenPri OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Regenerated Priority value determined for the input CLASS."
|
|
::= { fsQoSClassToPriorityEntry 2 }
|
|
|
|
fsQoSClassToPriorityGroupName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is for unique identification of the group to which a input
|
|
CLASS belongs."
|
|
::= { fsQoSClassToPriorityEntry 3 }
|
|
|
|
fsQoSClassToPriorityStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. All writable objects in this
|
|
row may be modified only when the row status is not active.
|
|
it can be deleted 'destroy', only if it is not referenced
|
|
by other table; otherwise return inconsistentValue error."
|
|
::= { fsQoSClassToPriorityEntry 4 }
|
|
|
|
-- ========================================================================== --
|
|
-- Meter Table --
|
|
-- ========================================================================== --
|
|
|
|
-- The below is as per RFC 3289 ( std qos diffserv mib).
|
|
|
|
-- This MIB supports a variety of Meters. It includes a specific
|
|
-- definition for Token Bucket Meter, which are but one type of
|
|
-- specification.
|
|
|
|
-- Configuration of various meter parameters is as follows :
|
|
-- AvgRate meter
|
|
-- Average Rate = CIR
|
|
-- Avg. Interval = Interval
|
|
|
|
-- srTCM meters (RFC 2697) can be specified using CIR, CBS and EBS.
|
|
|
|
-- trTCM meters (RFC 2698) can be specified using CIR, CBS, PIR, PBS where
|
|
-- PIR = EIR,
|
|
-- PBS = EBS.
|
|
|
|
-- tswTCM meters (RFC 2859) can be specified using CTR, PTR and Avg. Interval
|
|
-- where
|
|
-- CTR = CIR,
|
|
-- PTR = EIR
|
|
-- Average Interval = Interval.
|
|
|
|
-- MEF based meter bandwidth attributes -
|
|
-- CIR, EIR , CBS, EBS where EBS should mean max burst size.
|
|
-- single bucket parameters - CIR, CBS, EBS
|
|
-- dual bucket parameters - CIR, EIR, CBS and EBS where EIR - max rate
|
|
--
|
|
|
|
fsQoSMeterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSMeterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table enumerates specific meters that a system may use to
|
|
police a stream of traffic. This may include all traffic on an
|
|
interface."
|
|
::= { fsQoSPolicy 1 }
|
|
|
|
fsQoSMeterEntry OBJECT-TYPE
|
|
SYNTAX FsQoSMeterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the meter table describes a single conformance level
|
|
of a meter."
|
|
INDEX { fsQoSMeterId }
|
|
::= { fsQoSMeterTable 1 }
|
|
|
|
FsQoSMeterEntry ::= SEQUENCE {
|
|
fsQoSMeterId IndexInteger,
|
|
fsQoSMeterName DisplayString,
|
|
fsQoSMeterType MeterType,
|
|
fsQoSMeterInterval Unsigned32,
|
|
fsQoSMeterColorMode MeterColorMode,
|
|
fsQoSMeterCIR Unsigned32,
|
|
fsQoSMeterCBS Unsigned32,
|
|
fsQoSMeterEIR Unsigned32,
|
|
fsQoSMeterEBS Unsigned32,
|
|
fsQoSMeterNext Unsigned32,
|
|
fsQoSMeterStatus RowStatus
|
|
}
|
|
|
|
fsQoSMeterId OBJECT-TYPE
|
|
SYNTAX IndexInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that enumerates the Meter entries."
|
|
::= { fsQoSMeterEntry 1 }
|
|
|
|
fsQoSMeterName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the Name for the meter entry.
|
|
It should be unique in this Table."
|
|
::= { fsQoSMeterEntry 2 }
|
|
|
|
fsQoSMeterType OBJECT-TYPE
|
|
SYNTAX MeterType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Metering algorithm associated with the Token Bucket meter."
|
|
::= { fsQoSMeterEntry 3 }
|
|
|
|
fsQoSMeterInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..10000)
|
|
UNITS "microseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time interval used with the token bucket. For:
|
|
1. Average Rate Meter, the Informal Differentiated Services Model
|
|
section 5.2.1, - Delta.
|
|
2. Simple Token Bucket Meter, the Informal Differentiated
|
|
Services Model section 5.1, - time interval t.
|
|
3. RFC 2859 TSWTCM, - AVG_INTERVAL.
|
|
4. RFC 2697 srTCM, RFC 2698 trTCM, - token bucket update time
|
|
interval."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSMeterEntry 4 }
|
|
|
|
fsQoSMeterColorMode OBJECT-TYPE
|
|
SYNTAX MeterColorMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The user defined Meter Color Mode."
|
|
DEFVAL { colorBlind }
|
|
::= { fsQoSMeterEntry 5 }
|
|
|
|
fsQoSMeterCIR OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The committed information rate as per MEF.
|
|
Must be >= 0. CIR must be less than or equal to EIR, if EIR > 0"
|
|
::= { fsQoSMeterEntry 6 }
|
|
|
|
fsQoSMeterCBS OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "Bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The committed burst size as per MEF. Must be > 0 if CIR > 0.
|
|
Maximum allowable size will be jumbo frame size."
|
|
::= { fsQoSMeterEntry 7 }
|
|
|
|
fsQoSMeterEIR OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The excess information rate as per MEF.
|
|
Must be >= 0. EIR must be greater than or equal to CIR,
|
|
if EIR > 0. This is not applicable when MeterType is srtcm."
|
|
::= { fsQoSMeterEntry 8 }
|
|
|
|
fsQoSMeterEBS OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "Bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The excess burst size as per MEF. Must be > 0 if EIR > 0."
|
|
::= { fsQoSMeterEntry 9 }
|
|
|
|
fsQoSMeterNext OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This specifies the meter entry ID to be used for applying the
|
|
second/next level of conformance on the incoming packet. A valid
|
|
value of this object is not mandatory for the creation of an
|
|
entry in the conceptual row."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSMeterEntry 10 }
|
|
|
|
fsQoSMeterStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. All writable objects in this
|
|
row may be modified only of the Entry is not ACTIVE.
|
|
It can be deleted 'destroy', only if it is not referenced
|
|
by other table; otherwise return inconsistentValue error."
|
|
::= { fsQoSMeterEntry 11 }
|
|
|
|
-- ========================================================================== --
|
|
-- Policy-Map Table ( ClassMap To PolicyMap Table ) --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSPolicyMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSPolicyMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table contains the class-map to policy-map details."
|
|
::= { fsQoSPolicy 2 }
|
|
|
|
fsQoSPolicyMapEntry OBJECT-TYPE
|
|
SYNTAX FsQoSPolicyMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry to map a policy for a class-map."
|
|
INDEX { fsQoSPolicyMapId }
|
|
::= { fsQoSPolicyMapTable 1 }
|
|
|
|
FsQoSPolicyMapEntry ::= SEQUENCE {
|
|
fsQoSPolicyMapId IndexInteger,
|
|
fsQoSPolicyMapName DisplayString,
|
|
-- inputs
|
|
fsQoSPolicyMapIfIndex Unsigned32,
|
|
fsQoSPolicyMapCLASS Unsigned32,
|
|
-- outputs
|
|
fsQoSPolicyMapPHBType INTEGER,
|
|
fsQoSPolicyMapDefaultPHB Unsigned32, -- default outgoing priority
|
|
fsQoSPolicyMapMeterTableId Unsigned32, -- meter
|
|
fsQoSPolicyMapFailMeterTableId Unsigned32,
|
|
-- actions
|
|
fsQoSPolicyMapInProfileConformActionId Unsigned32,
|
|
fsQoSPolicyMapInProfileConformActionFlag BITS,
|
|
fsQoSPolicyMapInProfileActionSetPort Unsigned32, -- for conform, exceed actions
|
|
fsQoSPolicyMapConformActionSetIpTOS Unsigned32,
|
|
fsQoSPolicyMapConformActionSetDscp Dscp,
|
|
fsQoSPolicyMapConformActionSetVlanPrio Unsigned32,
|
|
fsQoSPolicyMapConformActionSetVlanDE Unsigned32,
|
|
fsQoSPolicyMapConformActionSetInnerVlanPrio Unsigned32,
|
|
fsQoSPolicyMapConformActionSetMplsExp Unsigned32,
|
|
fsQoSPolicyMapConformActionSetNewCLASS Unsigned32,
|
|
fsQoSPolicyMapInProfileExceedActionId Unsigned32,
|
|
fsQoSPolicyMapInProfileExceedActionFlag BITS,
|
|
fsQoSPolicyMapExceedActionSetIpTOS Unsigned32,
|
|
fsQoSPolicyMapExceedActionSetDscp Dscp,
|
|
fsQoSPolicyMapExceedActionSetInnerVlanPrio Unsigned32,
|
|
fsQoSPolicyMapExceedActionSetVlanPrio Unsigned32,
|
|
fsQoSPolicyMapExceedActionSetVlanDE Unsigned32,
|
|
fsQoSPolicyMapExceedActionSetMplsExp Unsigned32,
|
|
fsQoSPolicyMapExceedActionSetNewCLASS Unsigned32,
|
|
fsQoSPolicyMapOutProfileActionId Unsigned32,
|
|
fsQoSPolicyMapOutProfileActionFlag BITS,
|
|
fsQoSPolicyMapOutProfileActionSetIPTOS Unsigned32,
|
|
fsQoSPolicyMapOutProfileActionSetDscp Dscp,
|
|
fsQoSPolicyMapOutProfileActionSetInnerVlanPrio Unsigned32,
|
|
fsQoSPolicyMapOutProfileActionSetVlanPrio Unsigned32,
|
|
fsQoSPolicyMapOutProfileActionSetVlanDE Unsigned32,
|
|
fsQoSPolicyMapOutProfileActionSetMplsExp Unsigned32,
|
|
fsQoSPolicyMapOutProfileActionSetNewCLASS Unsigned32,
|
|
fsQoSPolicyMapStatus RowStatus,
|
|
fsQoSPolicyMapConformActionSetInnerVlanDE Unsigned32,
|
|
fsQoSPolicyMapExceedActionSetInnerVlanDE Unsigned32,
|
|
fsQoSPolicyMapOutProfileActionSetInnerVlanDE Unsigned32,
|
|
fsQoSPolicyDefaultVlanDE INTEGER
|
|
}
|
|
|
|
fsQoSPolicyMapId OBJECT-TYPE
|
|
SYNTAX IndexInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An index that enumerates the policy-map table entries."
|
|
::= { fsQoSPolicyMapEntry 1 }
|
|
|
|
fsQoSPolicyMapName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This the Name for a policy entry. It should be unique in this Table."
|
|
::= { fsQoSPolicyMapEntry 2 }
|
|
|
|
fsQoSPolicyMapIfIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the incoming interface identifier for which the policy
|
|
map is applied. A Valid value of this object is not mandatory for the
|
|
creation of an entry in this table."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 3 }
|
|
|
|
fsQoSPolicyMapCLASS OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the Traffic CLASS for which the policy-map
|
|
needs to be applied. A valid value is not necessary for
|
|
creation of an entry in this table. When this object is configured as
|
|
dont-care(0), it is mandatory that the PolicyMapIfIndex is
|
|
configured. This implies that the policy is interface-specific
|
|
and not CLASS-specific."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 4 }
|
|
|
|
fsQoSPolicyMapPHBType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
vlanPri(1),
|
|
ipTos(2),
|
|
ipDscp(3),
|
|
mplsExp(4),
|
|
dot1P(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "It indicates the PHB type to be used for filling the Default PHB
|
|
for the policy-map entry."
|
|
::= { fsQoSPolicyMapEntry 5 }
|
|
|
|
fsQoSPolicyMapDefaultPHB OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "It indicate the default out going PHB Values for the
|
|
Policy-Map. It may be overriden by the Meter used for the policy-map.
|
|
This value is interpreted by fsQoSPolicyMapPHBType."
|
|
::= { fsQoSPolicyMapEntry 6 }
|
|
|
|
fsQoSPolicyMapMeterTableId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Object refers to a Meter table Id which is the index
|
|
for the Meter table. A Valid value of this object is
|
|
not mandatory for the creation of an entry in this table."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 7 }
|
|
|
|
fsQoSPolicyMapFailMeterTableId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Object refers to a Meter table Id which is the index
|
|
of the Meter pointed to by diffServMeterFailNext.
|
|
A Valid value of this object is not mandatory for the
|
|
creation of an entry in this table."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 8 }
|
|
|
|
|
|
fsQoSPolicyMapInProfileConformActionFlag OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
none(0),
|
|
setFlagPort(1),
|
|
setFlagConfTos(2), -- mark TOS
|
|
setFlagConfDscp(3), -- mark DSCP
|
|
setFlagConfVlanPrio(4), -- mark vlan priority
|
|
setFlagConfVlanDE(5), -- mark vlan DE
|
|
setFlagConfInnerVlanPrio(6), -- mark inner vlan priority
|
|
setFlagConfMplsExp(7), -- mark MPLS exp
|
|
setFlagConfInnerVlanDE(8) -- mark inner vlan DEI
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object defines the action to be performed on the packet,
|
|
when the packets are found to be In profile."
|
|
::= { fsQoSPolicyMapEntry 9 }
|
|
|
|
fsQoSPolicyMapInProfileConformActionId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Object refers to an Action table Id which is the index
|
|
for the Action table. This is for the reference of the StdQos mib.
|
|
where we have to mention an action table for each action.
|
|
A Valid value of this object is
|
|
not mandatory for the creation of an entry in this table."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 10 }
|
|
|
|
|
|
fsQoSPolicyMapInProfileActionSetPort OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object sets the new port value in case the action
|
|
selected by fsQoSPolicyMapInProfileActionFlag is to assign a new
|
|
out port value."
|
|
::= { fsQoSPolicyMapEntry 11 }
|
|
|
|
fsQoSPolicyMapConformActionSetIpTOS OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object sets the new IP TOS value in case the action
|
|
selected by fsQoSPolicyMapInProfileActionFlag is to assign a new
|
|
IP TOS value."
|
|
::= { fsQoSPolicyMapEntry 12 }
|
|
|
|
fsQoSPolicyMapConformActionSetDscp OBJECT-TYPE
|
|
SYNTAX Dscp
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object sets the new DSCP value in case the action
|
|
selected by fsQoSPolicyMapInProfileActionFlag is to assign a new
|
|
DSCP value."
|
|
::= { fsQoSPolicyMapEntry 13 }
|
|
|
|
fsQoSPolicyMapConformActionSetVlanPrio OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..7 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Vlan Priority of the outgoing packet.
|
|
Setting of Vlan Priority is mutually exclusive to setting of Mpls EXP bits.
|
|
So setting the Vlan Priority to a non-zero value is only allowed when MplsExp is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 14 }
|
|
|
|
fsQoSPolicyMapConformActionSetVlanDE OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..1 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the VLAN Drop Eligible Indicator of the outgoing packet.
|
|
This is applicable ONLY when MplsExp is 0"
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 15 }
|
|
|
|
fsQoSPolicyMapConformActionSetInnerVlanPrio OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..7 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Inner Vlan Priority of the outgoing packet."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 16 }
|
|
|
|
fsQoSPolicyMapConformActionSetMplsExp OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..7 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Mpls Experimental bits of the outgoing packet.
|
|
Either Vlan Priority can be set OR Mpls EXP bits
|
|
can be set. So setting the Mpls EXP to a non 0
|
|
value is only allowed when Vlan Prio is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 17 }
|
|
|
|
fsQoSPolicyMapConformActionSetNewCLASS OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the Traffic CLASS to which an incoming frame pattern
|
|
is classified after metering. The priority of the New CLASS should
|
|
be lower as compared to the CLASS assigned prior to metering.
|
|
The administrator needs to ensure that the new CLASS belongs
|
|
to the same logical group as the CLASS assigned prior to metering.
|
|
In cases where lower priority CLASS cannot be assigned, the
|
|
administrator needs to appropriately configure for dropping the packet.
|
|
"
|
|
::= { fsQoSPolicyMapEntry 18 }
|
|
|
|
fsQoSPolicyMapInProfileExceedActionFlag OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
setFlagExcDrop(0),
|
|
setFlagExcTos(1), -- mark for exceed action
|
|
setFlagExcDscp(2),
|
|
setFlagExcVlanPrio(3),
|
|
setFlagExcVlanDE(4),
|
|
setFlagExcInnerVlanPrio(5),
|
|
setFlagExcMplsExp(6),
|
|
setFlagExcInnerVlanDE(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object defines the action to be performed on the packet,
|
|
when the packets are found to be In profile."
|
|
::= { fsQoSPolicyMapEntry 19 }
|
|
|
|
fsQoSPolicyMapInProfileExceedActionId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Object refers to an Action table Id which is the index
|
|
for the Action table. This is for the reference of the StdQos mib.
|
|
where we have to mention an action table for each action.
|
|
A Valid value of this object is
|
|
not mandatory for the creation of an entry in this table."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 20 }
|
|
|
|
|
|
fsQoSPolicyMapExceedActionSetIpTOS OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object sets the new IP TOS value in case the action
|
|
selected by fsQoSPolicyMapInProfileActionFlag is to assign a new
|
|
IP TOS value."
|
|
::= { fsQoSPolicyMapEntry 21 }
|
|
|
|
fsQoSPolicyMapExceedActionSetDscp OBJECT-TYPE
|
|
SYNTAX Dscp
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object sets the new DSCP value in case the action
|
|
selected by fsQoSPolicyMapInProfileActionFlag is to assign a new
|
|
DSCP value."
|
|
::= { fsQoSPolicyMapEntry 22 }
|
|
|
|
fsQoSPolicyMapExceedActionSetInnerVlanPrio OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..7 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Vlan Priority of the outgoing packet.
|
|
Either Vlan Priority can be set OR Mpls EXP bits
|
|
can be set. So setting the Vlan Priority to a non-zero
|
|
value is only allowed when MplsExp is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 23 }
|
|
|
|
fsQoSPolicyMapExceedActionSetVlanPrio OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..7 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Inner-Vlan Priority of the outgoing packet."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 24 }
|
|
|
|
fsQoSPolicyMapExceedActionSetVlanDE OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..1 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the VLAN Drop Eligible Indicator of the outgoing packet.
|
|
This is applicable ONLY when MplsEXP is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 25 }
|
|
|
|
fsQoSPolicyMapExceedActionSetMplsExp OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..7 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Mpls Experimental bits of the outgoing packet.
|
|
Either Vlan Priority can be set OR Mpls EXP bits
|
|
can be set. So setting the Mpls EXP to a non-zero
|
|
value is only allowed when Vlan Prio is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 26 }
|
|
|
|
fsQoSPolicyMapExceedActionSetNewCLASS OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the Traffic CLASS to which an incoming frame pattern
|
|
is classified after metering. The priority of the New CLASS should
|
|
be lower as compared to the CLASS assigned prior to metering.
|
|
The administrator needs to ensure that the new CLASS belongs
|
|
to the same logical group as the CLASS assigned prior to metering.
|
|
In cases where lower priority CLASS cannot be assigned, the
|
|
administrator needs to appropriately configure for dropping the packet.
|
|
"
|
|
::= { fsQoSPolicyMapEntry 27 }
|
|
|
|
fsQoSPolicyMapOutProfileActionFlag OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
setFlagDrop(0), -- packet is dropped
|
|
setFlagTos(1), -- mark IP TOS
|
|
setFlagDscp(2), -- mark DSCP
|
|
setFlagVlanPrio(3), -- mark VLAN priority
|
|
setFlagVlanDE(4), -- mark VLAN DE
|
|
setFlagConfInnerVlanPrio(5), -- mark inner vlan priority
|
|
setFlagMplsExp(6), -- mark MPLS EXP bits
|
|
setFlagConfInnerVlanDE(7) -- mark inner vlan DEI
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object defines the action to be performed on the packet
|
|
when the packets are found to be out of profile."
|
|
::= { fsQoSPolicyMapEntry 28 }
|
|
|
|
fsQoSPolicyMapOutProfileActionId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Object refers to an Action table Id which is the index
|
|
for the Action table. This is for the reference of the StdQos mib.
|
|
where we have to mention an action table for each action.
|
|
A Valid value of this object is
|
|
not mandatory for the creation of an entry in this table."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 29 }
|
|
|
|
|
|
fsQoSPolicyMapOutProfileActionSetIPTOS OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object sets the new IP TOS value in case the action
|
|
selected by fsQoSPolicyMapOutProfileActionFlag is to assign a new
|
|
Ip TOS value."
|
|
::= { fsQoSPolicyMapEntry 30 }
|
|
|
|
fsQoSPolicyMapOutProfileActionSetDscp OBJECT-TYPE
|
|
SYNTAX Dscp
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object sets the new DSCP value in case the action
|
|
selected by fsQoSPolicyMapOutProfileActionFlag is to assign
|
|
a new DSCP value."
|
|
::= { fsQoSPolicyMapEntry 31 }
|
|
|
|
fsQoSPolicyMapOutProfileActionSetInnerVlanPrio OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..7 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Vlan Priority of the outgoing packet.
|
|
Either Vlan Priority can be set OR Mpls EXP bits
|
|
can be set. So setting the Vlan Priority to a non-zero
|
|
value is only allowed when is MplsExp is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 32 }
|
|
|
|
|
|
fsQoSPolicyMapOutProfileActionSetVlanPrio OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..7 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Inner Vlan Priority of the outgoing packet.
|
|
Either Vlan Priority can be set OR Mpls EXP bits
|
|
can be set. So setting the Vlan Priority to a non-zero
|
|
value is only allowed when is MplsExp is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 33 }
|
|
|
|
fsQoSPolicyMapOutProfileActionSetVlanDE OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..1 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the VLAN Drop Eligible Indicator of the outgoing packet.
|
|
This is applicable ONLY when MplsEXP is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 34 }
|
|
|
|
fsQoSPolicyMapOutProfileActionSetMplsExp OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..7 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Mpls Experimental bits of the outgoing packet.
|
|
Either Vlan Priority can be set OR Mpls EXP bits
|
|
can be set. So setting the Mpls EXP to a non-zero
|
|
value is only allowed when is Vlan Prio is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 35 }
|
|
|
|
fsQoSPolicyMapOutProfileActionSetNewCLASS OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the Traffic CLASS to which an incoming frame pattern
|
|
is classified after metering. The priority of the New CLASS should
|
|
be lower as compared to the CLASS assigned prior to metering.
|
|
The administrator needs to ensure that the new CLASS belongs
|
|
to the same logical group as the CLASS assigned prior to metering. In cases,
|
|
where lower-priority CLASS cannot be assigned, administrator needs to
|
|
appropriately configure for dropping the packet."
|
|
::= { fsQoSPolicyMapEntry 36 }
|
|
|
|
fsQoSPolicyMapStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row."
|
|
::= { fsQoSPolicyMapEntry 37 }
|
|
|
|
fsQoSPolicyMapConformActionSetInnerVlanDE OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..1 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Inner VLAN Drop Eligible Indicator of the outgoing packet.
|
|
Either Inner VLAN DE can be set OR Mpls EXP bits can be set. So setting
|
|
the Inner VLAN DE is only allowed when MplsExp is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 38 }
|
|
|
|
fsQoSPolicyMapExceedActionSetInnerVlanDE OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..1 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Inner VLAN Drop Eligible Indicator of the outgoing packet.
|
|
Either Inner VLAN DE can be set OR Mpls EXP bits can be set. So setting
|
|
the Inner VLAN DE is only allowed when MplsExp is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 39 }
|
|
|
|
fsQoSPolicyMapOutProfileActionSetInnerVlanDE OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..1 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the Inner VLAN Drop Eligible Indicator of the outgoing packet.
|
|
Either Inner VLAN DE can be set OR Mpls EXP bits can be set. So setting
|
|
the Inner VLAN DE is only allowed when MplsExp is 0."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 40 }
|
|
|
|
fsQoSPolicyDefaultVlanDE OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..1 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set the VLAN Drop Eligible Indicator of the outgoing packet."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSPolicyMapEntry 41 }
|
|
|
|
-- ========================================================================== --
|
|
-- Queue Template Table : --
|
|
-- A template to specify the queue parameters ,the policing algo parameters --
|
|
-- applied on the queue. --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSQTemplateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSQTemplateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The queue template table configures the queue attributes.
|
|
The template is re-used for configuring multiple queues."
|
|
::= { fsQoSTrafficMgmt 1 }
|
|
|
|
fsQoSQTemplateEntry OBJECT-TYPE
|
|
SYNTAX FsQoSQTemplateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Each entry in the table is a Queue Template Configuration."
|
|
INDEX { fsQoSQTemplateId }
|
|
::= { fsQoSQTemplateTable 1 }
|
|
|
|
FsQoSQTemplateEntry ::= SEQUENCE {
|
|
fsQoSQTemplateId IndexInteger,
|
|
fsQoSQTemplateName DisplayString,
|
|
fsQoSQTemplateDropType INTEGER,
|
|
fsQoSQTemplateDropAlgoEnableFlag EnableStatus,
|
|
fsQoSQTemplateSize Unsigned32,
|
|
fsQoSQTemplateStatus RowStatus
|
|
}
|
|
|
|
fsQoSQTemplateId OBJECT-TYPE
|
|
SYNTAX IndexInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Queue Template Table Index."
|
|
::= { fsQoSQTemplateEntry 1 }
|
|
|
|
fsQoSQTemplateName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This the Name for a Entry. It should be unique in this Table."
|
|
::= { fsQoSQTemplateEntry 2 }
|
|
|
|
fsQoSQTemplateDropType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
tailDrop(2),
|
|
headDrop(3),
|
|
red(4),
|
|
alwaysDrop(5),
|
|
wred(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of drop algorithm used by this queue template. The value
|
|
other(1)requires further specification in some other MIB module.
|
|
|
|
In the tailDrop(2) algorithm, fsQoSQTemplateSize
|
|
represents the maximum depth of the queue, beyond which all newly
|
|
arriving packets will be dropped.
|
|
|
|
In the headDrop(3) algorithm, if a packet arrives when the current
|
|
depth of the queue, is at fsQoSQTemplateSize , packets
|
|
currently at the head of the queue are dropped to make room for the
|
|
new packet to be enqueued at the tail of the queue.
|
|
|
|
In the random Drop(4) and (6) algorithms, on packet arrival, an Active
|
|
Queue Management algorithm is executed which may randomly drop a
|
|
packet. This algorithm may be proprietary, and it may drop either
|
|
the arriving packet or another packet in the queue.
|
|
For this algorithm, fsQoSQTemplateSize is understood to
|
|
be the absolute maximum size of the queue and additional parameters are
|
|
described in fsQoSRandomDetectCfgTable.
|
|
|
|
The alwaysDrop(5) algorithm is as its name specifies; always
|
|
drop. In this case, the other configuration values in this Entry
|
|
are not meaningful"
|
|
::= { fsQoSQTemplateEntry 3 }
|
|
|
|
fsQoSQTemplateDropAlgoEnableFlag OBJECT-TYPE
|
|
SYNTAX EnableStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enable/disable Drop Algorithm for Congestion Management"
|
|
DEFVAL { disable }
|
|
::= { fsQoSQTemplateEntry 4 }
|
|
|
|
fsQoSQTemplateSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Queue Size. This must be greater than or equal to the
|
|
fsQoSRandomDetectCfgMinAvgThresh and less-than/equal to
|
|
fsQoSRandomDetectCfgMaxAvgThresh if Random Detection is enabled.
|
|
This is depth in bytes of the queue being measured, at
|
|
which a trigger is generated to the dropping algorithm.
|
|
For the tailDrop(2) or headDrop(3) algorithms, this represents
|
|
the depth of the queue, at which the drop action will take place.
|
|
Other algorithms will need to define their own semantics for this
|
|
threshold."
|
|
::= { fsQoSQTemplateEntry 5 }
|
|
|
|
fsQoSQTemplateStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. All writable objects in this
|
|
row may be modified at any time.
|
|
It can be deleted 'destroy', only if it is not referenced
|
|
by other table; otherwise return inconsistentValue error."
|
|
::= { fsQoSQTemplateEntry 6 }
|
|
|
|
-- ========================================================================== --
|
|
-- RED configuration for Q Congestion Management --
|
|
-- The below is configured if RED needs to be enabled in the system. --
|
|
-- fsQoSQTemplateDropSpecific points to an entry in this --
|
|
-- table. --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSRandomDetectCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSRandomDetectCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table to configure parameters for Random Detect Algorithm.
|
|
The table is Indexed by fsQoSQTemplateId and
|
|
Drop Precedence (DP) (0 - 2).
|
|
Each entry represent random detect configurations
|
|
per QueueTemplate per Drop Precedence."
|
|
|
|
::= { fsQoSTrafficMgmt 2 }
|
|
|
|
fsQoSRandomDetectCfgEntry OBJECT-TYPE
|
|
SYNTAX FsQoSRandomDetectCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry in the table is a random drop Configuration."
|
|
INDEX { fsQoSQTemplateId , fsQoSRandomDetectCfgDP }
|
|
::= { fsQoSRandomDetectCfgTable 1 }
|
|
|
|
FsQoSRandomDetectCfgEntry ::=
|
|
SEQUENCE {
|
|
fsQoSRandomDetectCfgDP Integer32,
|
|
fsQoSRandomDetectCfgMinAvgThresh Unsigned32,
|
|
fsQoSRandomDetectCfgMaxAvgThresh Unsigned32,
|
|
fsQoSRandomDetectCfgMaxPktSize Unsigned32,
|
|
fsQoSRandomDetectCfgMaxProb Unsigned32,
|
|
fsQoSRandomDetectCfgExpWeight Unsigned32,
|
|
fsQoSRandomDetectCfgStatus RowStatus,
|
|
fsQoSRandomDetectCfgGain Unsigned32,
|
|
fsQoSRandomDetectCfgDropThreshType INTEGER,
|
|
fsQoSRandomDetectCfgECNThresh Unsigned32,
|
|
fsQoSRandomDetectCfgActionFlag BITS
|
|
}
|
|
|
|
fsQoSRandomDetectCfgDP OBJECT-TYPE
|
|
SYNTAX Integer32(0..5)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The Drop Precedence [Drop Profile]
|
|
0 - low drop precedence[TCP Green Discard]
|
|
1 - medium drop precedence[TCP Yellow Discard]
|
|
2 - high drop precedence[TCP Red Discard]
|
|
3 - [NON-TCP Green Discard]
|
|
4 - [NON-TCP Yellow Discard]
|
|
5 - [NON-TCP Red Discard]"
|
|
::= { fsQoSRandomDetectCfgEntry 1 }
|
|
|
|
fsQoSRandomDetectCfgMinAvgThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum average threshold for the random detect algorithm.
|
|
Below this threshold, packets are admitted into the queue.
|
|
The units are bits in accordance with Traffic Manager.
|
|
This must be less than or equal to the
|
|
fsQoSRandomDetectCfgMaxAvgThresh and the Queue size."
|
|
::= { fsQoSRandomDetectCfgEntry 2 }
|
|
|
|
fsQoSRandomDetectCfgMaxAvgThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum average threshold for the random detect algorithm.
|
|
Above this threshold, packets are discarded before entering
|
|
the queue. The units is bits in accordance with Traffic Manager.
|
|
This must be greater than or equal to the
|
|
fsQoSRandomDetectCfgMinAvgThresh and less than or equal to the
|
|
Queue size."
|
|
::= { fsQoSRandomDetectCfgEntry 3 }
|
|
|
|
fsQoSRandomDetectCfgMaxPktSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Maximum allowed Packet Size. The units is bytes."
|
|
::= { fsQoSRandomDetectCfgEntry 4 }
|
|
|
|
fsQoSRandomDetectCfgMaxProb OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum probability of discarding a packet in units of percentage."
|
|
DEFVAL { 100 }
|
|
::= { fsQoSRandomDetectCfgEntry 5 }
|
|
|
|
fsQoSRandomDetectCfgExpWeight OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..31)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The exponential Weight for determining the average queue size."
|
|
DEFVAL{ 0 }
|
|
::= { fsQoSRandomDetectCfgEntry 6 }
|
|
|
|
fsQoSRandomDetectCfgStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. All writable objects in this
|
|
row may be modified at any time.
|
|
It can be deleted 'destroy', only if it is not referenced
|
|
by other table; otherwise return inconsistentValue error."
|
|
::= { fsQoSRandomDetectCfgEntry 7 }
|
|
|
|
fsQoSRandomDetectCfgGain OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gain defines an increase in drop-probability on each granular
|
|
increase of buffer-occupancy due to received traffic.
|
|
Determines the smoothing that should be applied."
|
|
|
|
::= { fsQoSRandomDetectCfgEntry 8 }
|
|
|
|
fsQoSRandomDetectCfgDropThreshType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
discardpackets(1),
|
|
discardbytes(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"discardpackets(1) sets the WRED drop type to Discard packets.
|
|
discardbytes(2) sets the WRED drop type to discard in terms of bytes.
|
|
Value configured for fsQoSRandomDetectCfgMinAvgThresh and
|
|
fsQoSRandomDetectCfgMaxAvgThresh is interpreted as Packets/Bytes
|
|
based on the this object configuration."
|
|
|
|
DEFVAL { 1 }
|
|
::= { fsQoSRandomDetectCfgEntry 9 }
|
|
|
|
fsQoSRandomDetectCfgECNThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the Queue depth in bytes to stop marking and start dropping
|
|
ECN eligible packets"
|
|
::= { fsQoSRandomDetectCfgEntry 10 }
|
|
|
|
fsQoSRandomDetectCfgActionFlag OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
none(0),
|
|
capavg(1),
|
|
markcongestion(2)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object defines the additional action flags for the WRED profiles,
|
|
Setting the flag to capavg(0) never lets the average queue size be bigger
|
|
than the actual queue size. markcongestion(1) marks the ECN instead of
|
|
dropping.
|
|
Action performed by this Flag configurations is dependent on the underlying
|
|
Platform, if the platform supports this configuration."
|
|
|
|
DEFVAL { 0 }
|
|
::= { fsQoSRandomDetectCfgEntry 11 }
|
|
|
|
-- ========================================================================== --
|
|
-- Shape Template Table --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSShapeTemplateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSShapeTemplateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The shape template table configures the shaper attributes."
|
|
::= { fsQoSTrafficMgmt 3 }
|
|
|
|
fsQoSShapeTemplateEntry OBJECT-TYPE
|
|
SYNTAX FsQoSShapeTemplateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Each entry in the table is a Shape Template Configuration."
|
|
INDEX { fsQoSShapeTemplateId }
|
|
::= { fsQoSShapeTemplateTable 1 }
|
|
|
|
FsQoSShapeTemplateEntry ::= SEQUENCE {
|
|
fsQoSShapeTemplateId IndexInteger,
|
|
fsQoSShapeTemplateName DisplayString,
|
|
fsQoSShapeTemplateCIR Unsigned32,
|
|
fsQoSShapeTemplateCBS Unsigned32,
|
|
fsQoSShapeTemplateEIR Unsigned32,
|
|
fsQoSShapeTemplateEBS Unsigned32,
|
|
fsQoSShapeTemplateStatus RowStatus
|
|
}
|
|
|
|
fsQoSShapeTemplateId OBJECT-TYPE
|
|
SYNTAX IndexInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Shape Template Table Index."
|
|
::= { fsQoSShapeTemplateEntry 1 }
|
|
|
|
fsQoSShapeTemplateName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This the Name for a Shape template Entry.
|
|
It should be unique in this Table."
|
|
::= { fsQoSShapeTemplateEntry 2 }
|
|
|
|
fsQoSShapeTemplateCIR OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The committed information rate for packets through this queue.
|
|
Must be > 0."
|
|
::= { fsQoSShapeTemplateEntry 3 }
|
|
|
|
fsQoSShapeTemplateCBS OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "Bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The committed burst size for packets through this queue.
|
|
Must be > 0 when CIR > 0."
|
|
::= { fsQoSShapeTemplateEntry 4 }
|
|
|
|
fsQoSShapeTemplateEIR OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Excess information rate for packets through this hierarchy.
|
|
Must be >= 0. EIR must be greater than or equal to CIR, if EIR > 0.
|
|
Currently not used, for future use.
|
|
Agent returns EIR = 0 to represent that this row is not configured by
|
|
the manager."
|
|
::= { fsQoSShapeTemplateEntry 5 }
|
|
|
|
fsQoSShapeTemplateEBS OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
UNITS "Bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The excess burst size for packets through this hierarchy.
|
|
Must be > 0 when EIR > 0. Currently not used, for future use.
|
|
Agent returns EBS = 0 to represent that this row is not configured by
|
|
the manager."
|
|
::= { fsQoSShapeTemplateEntry 6 }
|
|
|
|
fsQoSShapeTemplateStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. All writable objects in this
|
|
row may be modified at any time.
|
|
It can be deleted 'destroy', only if it is not referenced
|
|
by other table; otherwise return inconsistentValue error."
|
|
::= { fsQoSShapeTemplateEntry 7 }
|
|
|
|
-- ========================================================================== --
|
|
-- Queue Map Table --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSQMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSQMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Queue MAP table mapping an egress port,
|
|
CLASS of service to a queue."
|
|
::= { fsQoSTrafficMgmt 4 }
|
|
|
|
fsQoSQMapEntry OBJECT-TYPE
|
|
SYNTAX FsQoSQMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Q MAP Entry mapping a CLASS of service or
|
|
RegenPriority from the fsQoSPolicyMapTable to a queue."
|
|
INDEX { ifIndex, fsQoSQMapCLASS, fsQoSQMapRegenPriType,
|
|
fsQoSQMapRegenPriority }
|
|
::= { fsQoSQMapTable 1 }
|
|
|
|
FsQoSQMapEntry ::=
|
|
SEQUENCE {
|
|
fsQoSQMapCLASS Unsigned32,
|
|
fsQoSQMapRegenPriType INTEGER,
|
|
fsQoSQMapRegenPriority Unsigned32,
|
|
fsQoSQMapQId Unsigned32,
|
|
fsQoSQMapStatus RowStatus,
|
|
fsQoSQMapRegenDEI Unsigned32,
|
|
fsQoSQMapRegenColor Unsigned32
|
|
}
|
|
|
|
fsQoSQMapCLASS OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input CLASS ( associated with an incoming packet) that needs
|
|
to be mapped to an outbound queue. This is mutually exclusive to
|
|
the RegenPriority object. CLASS should be 0 while configuring
|
|
RegenPriority specific Q."
|
|
::= { fsQoSQMapEntry 1 }
|
|
|
|
fsQoSQMapRegenPriType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
vlanPri(1),
|
|
ipTos(2),
|
|
ipDscp(3),
|
|
mplsExp(4),
|
|
vlanDEI(5),
|
|
internalPrio(6),
|
|
dot1P(7)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The regenerated-priority type to interpret the value of
|
|
'fsQoSQMapRegenPriority' object. This object should be none
|
|
while configuring CLASS specific Queue.
|
|
|
|
If fsQoSQMapRegenPriType is internalPrio, then packets classified to
|
|
internal priority will be associated to queue with identfier
|
|
fsQoSQMapQId"
|
|
::= { fsQoSQMapEntry 2 }
|
|
|
|
fsQoSQMapRegenPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The regenerated-priority ( for an incoming packet) that needs
|
|
to be mapped to an outbound queue. This is mutually exclusive to
|
|
the CLASS configuration. This object should be 0 while configuring
|
|
CLASS specific Queue."
|
|
::= { fsQoSQMapEntry 3 }
|
|
|
|
fsQoSQMapQId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Queue Identifier that uniquely identifies a queue relative to an
|
|
interface. It could be configured with a unique value in the system."
|
|
::= { fsQoSQMapEntry 4 }
|
|
|
|
fsQoSQMapStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row. All writable objects in this
|
|
row may be modified only when the row status is not active.
|
|
It can be deleted/destroyed independent of other Traffic class tables;
|
|
For any mib table that supports global configurations (less-specific)
|
|
at runtime and H/W supports more-specific configurations,
|
|
if a more-specific entry is deleted by configuration, then the next
|
|
less-specific entry gets programmed to H/W
|
|
|
|
If the fsQoSQMapCLASS associated to this table refers the flow based
|
|
traffic classification, Interface index configuration as part fsQoSQMap
|
|
table is not required. Interface index associated on the L2/L3 filters
|
|
will be applicable for QueueMapping as well.
|
|
|
|
For Vlan based queueing, egress interface should be configured for
|
|
mapping the classified egress vlan traffic to subscriber queues."
|
|
|
|
::= { fsQoSQMapEntry 5 }
|
|
|
|
fsQoSQMapRegenDEI OBJECT-TYPE
|
|
SYNTAX INTEGER { false(0),
|
|
true(1)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Drop_eligible bit in the incoming frames.
|
|
Either it can take false(0) or true (1). By default,
|
|
drop_eligible bit is not set."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSQMapEntry 6 }
|
|
|
|
fsQoSQMapRegenColor OBJECT-TYPE
|
|
SYNTAX INTEGER { green(0), ---Traffic conforms to SLAs
|
|
yellow(1),---Traffic exceeds to SLAs
|
|
red(2) ---Traffic violates to SLAs
|
|
}
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the regenerated color used in COSQ mapping.
|
|
Administrator is not allowed to configure the color for Queue
|
|
Mapping. This object will reflect the color configured
|
|
in Priority Map."
|
|
::= { fsQoSQMapEntry 7 }
|
|
|
|
|
|
|
|
-- ========================================================================== --
|
|
-- Queue Table --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSQTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSQEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table describing the queue parameters"
|
|
::= { fsQoSTrafficMgmt 5 }
|
|
|
|
fsQoSQEntry OBJECT-TYPE
|
|
SYNTAX FsQoSQEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " Q table entry"
|
|
INDEX {ifIndex, fsQoSQId }
|
|
::= { fsQoSQTable 1 }
|
|
|
|
FsQoSQEntry ::=
|
|
SEQUENCE {
|
|
fsQoSQId Unsigned32,
|
|
fsQoSQCfgTemplateId Unsigned32,
|
|
fsQoSQSchedulerId Unsigned32,
|
|
fsQoSQWeight Unsigned32,
|
|
fsQoSQPriority Unsigned32,
|
|
fsQoSQShapeId Unsigned32,
|
|
fsQoSQStatus RowStatus,
|
|
fsQoSQType Unsigned32
|
|
}
|
|
|
|
fsQoSQId OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 1..65535 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Queue Identifier that uniquely identifies the queue
|
|
in the system/port."
|
|
::= { fsQoSQEntry 1 }
|
|
|
|
fsQoSQCfgTemplateId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Queue template Id applied for configuring queue attributes."
|
|
::= { fsQoSQEntry 2 }
|
|
|
|
fsQoSQSchedulerId OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 1..65535 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scheduler identifier that manages the specified queue.
|
|
This identifier is unique relative to an egress interface."
|
|
::= { fsQoSQEntry 3 }
|
|
|
|
fsQoSQWeight OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User assigned weight to the CoS queue.
|
|
The assigned weights are used only when scheduling
|
|
algorithm is a weighted scheduling algorithm."
|
|
DEFVAL { 1 }
|
|
::= { fsQoSQEntry 4 }
|
|
|
|
fsQoSQPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..15)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User assigned priority for the CoS queue.
|
|
The assigned priority is used only when the scheduler uses a
|
|
priority based scheduling algorithm."
|
|
DEFVAL { 1 }
|
|
::= { fsQoSQEntry 5 }
|
|
|
|
fsQoSQShapeId OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..65535 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The shaper identifier that specifies the bandwidth requirements
|
|
for the queue. This object is not mandatory for the
|
|
creation of the row."
|
|
::= { fsQoSQEntry 6 }
|
|
|
|
fsQoSQStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Row Status to Create/Destroy the entry.
|
|
It can be deleted 'destroy', only if it is not referenced
|
|
by other dependent tables; otherwise it returns inconsistentValue error."
|
|
::= { fsQoSQEntry 7 }
|
|
|
|
fsQoSQType OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..2)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the type of the queue.
|
|
1- Unicast queue
|
|
2- Multicast queue
|
|
3- Subscriber queue"
|
|
DEFVAL { 1 }
|
|
::= { fsQoSQEntry 8 }
|
|
|
|
-- ========================================================================== --
|
|
-- Scheduler Table --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSSchedulerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSSchedulerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Scheduler table "
|
|
::= { fsQoSTrafficMgmt 6 }
|
|
|
|
fsQoSSchedulerEntry OBJECT-TYPE
|
|
SYNTAX FsQoSSchedulerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Scheduler table Entry."
|
|
INDEX { ifIndex, fsQoSSchedulerId }
|
|
::= { fsQoSSchedulerTable 1 }
|
|
|
|
FsQoSSchedulerEntry ::=
|
|
SEQUENCE {
|
|
fsQoSSchedulerId Unsigned32,
|
|
fsQoSSchedulerSchedAlgorithm INTEGER,
|
|
fsQoSSchedulerShapeId Unsigned32,
|
|
fsQoSSchedulerHierarchyLevel Unsigned32,
|
|
fsQoSSchedulerGlobalId Unsigned32,
|
|
fsQoSSchedulerStatus RowStatus
|
|
}
|
|
|
|
fsQoSSchedulerId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Scheduler Identifier that uniquely identifies the
|
|
scheduler in the system/egress interface."
|
|
::= { fsQoSSchedulerEntry 1 }
|
|
|
|
fsQoSSchedulerSchedAlgorithm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
strictPriority(1),
|
|
roundRobin(2),
|
|
weightedRoundRobin(3),
|
|
weightedFairQueing(4),
|
|
strictRoundRobin(5),
|
|
strictWeightedRoundRobin(6),
|
|
strictWeightedFairQueing(7),
|
|
deficitRoundRobin(8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the packet scheduling algorithm for the port
|
|
The default is strictPriority(1)."
|
|
DEFVAL { 1 }
|
|
::= { fsQoSSchedulerEntry 2 }
|
|
|
|
fsQoSSchedulerShapeId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The shaper identifier that specifies the bandwidth requirements
|
|
for the scheduler. This object is not mandatory for the
|
|
creation of the conceptual row."
|
|
::= { fsQoSSchedulerEntry 3 }
|
|
|
|
fsQoSSchedulerHierarchyLevel OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the depth of the queue/scheduler hierarchy.
|
|
A value of 0 indicates that there is no hierarchy and that all
|
|
queues/schedulers are port-bound.
|
|
0 - No hierarchy
|
|
1 - S1 schedulers (attached to the egress port)
|
|
2 - S2 schedulers (next level attached to the S1 schecdulers)
|
|
3 - S3 schedulers (attached to the COS queues)"
|
|
DEFVAL {0}
|
|
::= { fsQoSSchedulerEntry 4 }
|
|
|
|
fsQoSSchedulerGlobalId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Scheduler Identifier that uniquely identifies the
|
|
scheduler in the system/egress interface.This object is
|
|
used only for creating Scheduler entry from the
|
|
standard QOS Scheduler table diffServSchedulerTable
|
|
as defined in RFC 3289. The Id corresponds to the
|
|
diffServSchedulerId in RFC 3289. This is added purely
|
|
for the purpose of Save/Restore"
|
|
::= { fsQoSSchedulerEntry 5 }
|
|
|
|
fsQoSSchedulerStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Row Status to Create/Destroy the entry.
|
|
It can be deleted 'destroy', only if it is not referenced
|
|
by other table; otherwise return inconsistentValue error."
|
|
::= { fsQoSSchedulerEntry 6 }
|
|
|
|
-- ========================================================================== --
|
|
-- Hierarchy Table : for hierarchical queuing/scheduling --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSHierarchyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSHierarchyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Hierarchy table for specifying the hierarchy details."
|
|
::= { fsQoSTrafficMgmt 7 }
|
|
|
|
fsQoSHierarchyEntry OBJECT-TYPE
|
|
SYNTAX FsQoSHierarchyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Each entry specifies the queue/scheduler details to be used
|
|
for the next level hierarchy. The interface index associated with
|
|
the NextQ or Next Scheduler is obtained from this table index
|
|
- 'ifIndex'."
|
|
INDEX { ifIndex, fsQoSHierarchyLevel, fsQoSSchedulerId }
|
|
::= { fsQoSHierarchyTable 1 }
|
|
|
|
FsQoSHierarchyEntry ::=
|
|
SEQUENCE {
|
|
fsQoSHierarchyLevel Unsigned32,
|
|
fsQoSHierarchyQNext Unsigned32,
|
|
fsQoSHierarchySchedNext Unsigned32,
|
|
fsQoSHierarchyWeight Unsigned32,
|
|
fsQoSHierarchyPriority SchedulerPriority,
|
|
fsQoSHierarchyStatus RowStatus
|
|
}
|
|
|
|
fsQoSHierarchyLevel OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..10)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the depth of the queue/scheduler hierarchy.
|
|
A value of 0 indicates that there is no hierarchy and that all
|
|
queues/schedulers are port-bound."
|
|
::= { fsQoSHierarchyEntry 1 }
|
|
|
|
fsQoSHierarchyQNext OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of this COSQ is sent to the scheduler attached to the queue.
|
|
For eg.,
|
|
A packet may flow from a cosq to the schedulers in the following way:
|
|
COSQ => S3 => S2 => S1 => Egress port.
|
|
The value of this object could be unique in the system/port.
|
|
A valid value is not mandatory for the creation of the conceptual row.
|
|
This object is used for hierarchical queuing."
|
|
::= { fsQoSHierarchyEntry 2 }
|
|
|
|
fsQoSHierarchySchedNext OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The next-level scheduler to which the scheduler output needs to
|
|
be sent. The value of this object could be unique in the system/port.
|
|
A valid value is not mandatory for the creation of the
|
|
conceptual row. This object is used for hierarchical scheduling."
|
|
::= { fsQoSHierarchyEntry 3 }
|
|
|
|
fsQoSHierarchyWeight OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..1000)
|
|
UNITS "Percentage"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Weight is specified if the Scheduler is connecting to a WFQ of
|
|
another Scheduler. Agent returns Weight = 0 to represent that this
|
|
object is not configured by the manager."
|
|
::= { fsQoSHierarchyEntry 4 }
|
|
|
|
fsQoSHierarchyPriority OBJECT-TYPE
|
|
SYNTAX SchedulerPriority
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Scheduler can connect to any of the Priority of the next-level
|
|
Scheduler. The priority is specified when the scheduler is
|
|
connecting to any of the priorities ( EF, AF, BE) of the
|
|
next level strict-priority scheduler. A value of 0 indicates
|
|
that this value is not configured by manager."
|
|
DEFVAL { 0 }
|
|
::= { fsQoSHierarchyEntry 5 }
|
|
|
|
fsQoSHierarchyStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Row Status to Create/Destroy the entry.
|
|
It can be deleted 'destroy', only if it is not referenced
|
|
by other table; otherwise return inconsistentValue error."
|
|
::= { fsQoSHierarchyEntry 6 }
|
|
|
|
-- ========================================================================== --
|
|
-- Default User Priority Table : for Untagged Packets --
|
|
-- and to specify preference for p-bit over dscp in case of tagged --
|
|
-- packets --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSDefUserPriorityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSDefUserPriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains default user priority for an interfae."
|
|
::= { fsQoSTrafficMgmt 8}
|
|
|
|
fsQoSDefUserPriorityEntry OBJECT-TYPE
|
|
SYNTAX FsQoSDefUserPriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table for configuring default user priority for each port. This is
|
|
used for assigning priority to the untagged packets received on the
|
|
interface."
|
|
INDEX { ifIndex }
|
|
::= { fsQoSDefUserPriorityTable 1 }
|
|
|
|
FsQoSDefUserPriorityEntry ::=
|
|
SEQUENCE {
|
|
fsQoSPortDefaultUserPriority Integer32,
|
|
fsQoSPortPbitPrefOverDscp INTEGER
|
|
}
|
|
|
|
fsQoSPortDefaultUserPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default ingress user priority for this port.
|
|
It will be used to set priority for an untagged Packets."
|
|
::= { fsQoSDefUserPriorityEntry 1 }
|
|
|
|
fsQoSPortPbitPrefOverDscp OBJECT-TYPE
|
|
SYNTAX INTEGER { enabled(1), disabled(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default pbit precedence for a port over DSCP is enabled.
|
|
It will be used to set preferece as P-Bit over DSCP
|
|
for the given tagged port."
|
|
DEFVAL { enabled }
|
|
::= { fsQoSDefUserPriorityEntry 2 }
|
|
|
|
-- ========================================================================== --
|
|
-- Policer Statistics Counters --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSPolicerStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSPolicerStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A list of Policer Statistics."
|
|
::= { fsQoSStats 1 }
|
|
|
|
fsQoSPolicerStatsEntry OBJECT-TYPE
|
|
SYNTAX FsQoSPolicerStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A collection of statistics kept for a particular Policer."
|
|
INDEX { fsQoSMeterId }
|
|
::= { fsQoSPolicerStatsTable 1 }
|
|
|
|
FsQoSPolicerStatsEntry ::=
|
|
SEQUENCE {
|
|
fsQoSPolicerStatsConformPkts Counter64,
|
|
fsQoSPolicerStatsConformOctets Counter64,
|
|
fsQoSPolicerStatsExceedPkts Counter64,
|
|
fsQoSPolicerStatsExceedOctets Counter64,
|
|
fsQoSPolicerStatsViolatePkts Counter64,
|
|
fsQoSPolicerStatsViolateOctets Counter64,
|
|
fsQoSPolicerStatsStatus EnableStatus,
|
|
fsQoSPolicerStatsClearCounter TruthValue
|
|
}
|
|
|
|
fsQoSPolicerStatsConformPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Packets marked down as conforming(Green) traffic
|
|
by this policer."
|
|
::= { fsQoSPolicerStatsEntry 1 }
|
|
|
|
fsQoSPolicerStatsConformOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Octets of traffic marked down as conforming(Green)
|
|
by this policer."
|
|
::= { fsQoSPolicerStatsEntry 2 }
|
|
|
|
fsQoSPolicerStatsExceedPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Packets marked down as exceeding(Yellow) traffic
|
|
by this policer."
|
|
::= { fsQoSPolicerStatsEntry 3 }
|
|
|
|
fsQoSPolicerStatsExceedOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Octets of traffic marked down as exceeding(Yellow)
|
|
by this policer."
|
|
::= { fsQoSPolicerStatsEntry 4 }
|
|
|
|
fsQoSPolicerStatsViolatePkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Packets marked down as violating(Red) traffic
|
|
by this policer."
|
|
::= { fsQoSPolicerStatsEntry 5 }
|
|
|
|
fsQoSPolicerStatsViolateOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Octets of traffic marked down as violating(Red)
|
|
by this policer."
|
|
::= { fsQoSPolicerStatsEntry 6 }
|
|
|
|
fsQoSPolicerStatsStatus OBJECT-TYPE
|
|
SYNTAX EnableStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status indicating the Policer Statistics is being Enabled/Disabled
|
|
for the specific meter.
|
|
|
|
When statistics collection is set to disabled, stops collecting
|
|
statistics in this table.
|
|
|
|
When statistics collection is set to enabled, starts collecting
|
|
statistics in the table"
|
|
DEFVAL { disable }
|
|
::= {fsQoSPolicerStatsEntry 7 }
|
|
|
|
fsQoSPolicerStatsClearCounter OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Resets all the counter variables to initialization value (zero)."
|
|
DEFVAL {false}
|
|
::= { fsQoSPolicerStatsEntry 8 }
|
|
|
|
-- ========================================================================== --
|
|
-- CoS based Statistics Counters --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSCoSQStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSCoSQStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of class-of-service based Queue Statistics for a COS Queue."
|
|
::= { fsQoSStats 2 }
|
|
|
|
fsQoSCoSQStatsEntry OBJECT-TYPE
|
|
SYNTAX FsQoSCoSQStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of CoS Queue statistics for a particular COS queue."
|
|
INDEX { ifIndex, fsQoSCoSQId }
|
|
::= { fsQoSCoSQStatsTable 1 }
|
|
|
|
FsQoSCoSQStatsEntry ::=
|
|
SEQUENCE {
|
|
fsQoSCoSQId Unsigned32,
|
|
fsQoSCoSQStatsEnQPkts Counter64,
|
|
fsQoSCoSQStatsEnQBytes Counter64,
|
|
fsQoSCoSQStatsDeQPkts Counter64,
|
|
fsQoSCoSQStatsDeQBytes Counter64,
|
|
fsQoSCoSQStatsDiscardPkts Counter64,
|
|
fsQoSCoSQStatsDiscardBytes Counter64,
|
|
fsQoSCoSQStatsOccupancy Counter64,
|
|
fsQoSCoSQStatsCongMgntAlgoDrop Counter64
|
|
}
|
|
|
|
fsQoSCoSQId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The COSQ for which the statistics is being collected."
|
|
::= { fsQoSCoSQStatsEntry 1 }
|
|
|
|
fsQoSCoSQStatsEnQPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of packets enqueued in this CoS Queue."
|
|
::= { fsQoSCoSQStatsEntry 2 }
|
|
|
|
fsQoSCoSQStatsEnQBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of bytes enqueued in this CoS Queue."
|
|
::= { fsQoSCoSQStatsEntry 3 }
|
|
|
|
fsQoSCoSQStatsDeQPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of packets de-queued from this CoS Queue."
|
|
::= { fsQoSCoSQStatsEntry 4 }
|
|
|
|
fsQoSCoSQStatsDeQBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of bytes de-queued from this CoS Queue."
|
|
::= { fsQoSCoSQStatsEntry 5 }
|
|
|
|
fsQoSCoSQStatsDiscardPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of packets discarded from this CoS Queue."
|
|
::= { fsQoSCoSQStatsEntry 6 }
|
|
|
|
fsQoSCoSQStatsDiscardBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of bytes discarded from this CoS Queue."
|
|
::= { fsQoSCoSQStatsEntry 7 }
|
|
|
|
fsQoSCoSQStatsOccupancy OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of bytes currently occupied in the CoS Queue."
|
|
::= { fsQoSCoSQStatsEntry 8 }
|
|
|
|
fsQoSCoSQStatsCongMgntAlgoDrop OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of bytes discarded due to congestion management
|
|
algorithm (RED/WRED) in this CoS Queue."
|
|
::= { fsQoSCoSQStatsEntry 9 }
|
|
|
|
-- Hardware CPU Rate Control Group
|
|
|
|
fsQosHwCpuRateLimitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQosHwCpuRateLimitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table describing the queue parameters for CPU port"
|
|
::= { fsQosHwCpuRateControl 1 }
|
|
|
|
fsQosHwCpuRateLimitEntry OBJECT-TYPE
|
|
SYNTAX FsQosHwCpuRateLimitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " CPU Rate Limit table entry"
|
|
INDEX {fsQosHwCpuQId }
|
|
::= { fsQosHwCpuRateLimitTable 1 }
|
|
|
|
FsQosHwCpuRateLimitEntry ::=
|
|
SEQUENCE {
|
|
fsQosHwCpuQId Unsigned32,
|
|
fsQosHwCpuMinRate Unsigned32,
|
|
fsQosHwCpuMaxRate Unsigned32,
|
|
fsQosHwCpuRowStatus RowStatus
|
|
}
|
|
|
|
fsQosHwCpuQId OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 1..65535 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Queue Identifier that uniquely identifies the queue
|
|
in the system/port."
|
|
::= { fsQosHwCpuRateLimitEntry 1 }
|
|
|
|
fsQosHwCpuMinRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls the minimum transmission rate
|
|
on a cpu port. Min Rate must be less than or equal
|
|
to Max Rate."
|
|
::= { fsQosHwCpuRateLimitEntry 2 }
|
|
|
|
fsQosHwCpuMaxRate OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 1..65535 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls the maximum transmission rate on
|
|
a cpu port. Max Rate must be greater than or equal to
|
|
Min Rate."
|
|
::= { fsQosHwCpuRateLimitEntry 3 }
|
|
|
|
fsQosHwCpuRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of this entry.
|
|
The entry in this table is used when the status of this object
|
|
is SET 'active'. The entry in this table is not used when this
|
|
object is SET 'notInService'."
|
|
::= { fsQosHwCpuRateLimitEntry 4 }
|
|
|
|
fsQoSVlanQueueingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to enable or disable Vlan Based Queueing
|
|
in the system. When set as 'enabled', QoS module programs the
|
|
hardware with the Hierarchical Scheduling Schema for Vlan based
|
|
queueing. When set as 'disabled', it removes the hardware
|
|
configuration."
|
|
DEFVAL { disabled }
|
|
::= { fsQoSSystem 6 }
|
|
|
|
-- ========================================================================== --
|
|
-- Vlan Map Table --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSVlanMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSVlanMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies a table to map incoming VLAN to a specific subscriber queue of a port."
|
|
::= { fsQoSClass 4 }
|
|
|
|
fsQoSVlanMapEntry OBJECT-TYPE
|
|
SYNTAX FsQoSVlanMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies an entry to map an incoming VLAN to a specific
|
|
Subscriber Queue of an Egress PORT. The ifIndex
|
|
value should be of egress member port of the VLAN."
|
|
INDEX { fsQoSVlanMapID }
|
|
::= { fsQoSVlanMapTable 1 }
|
|
|
|
FsQoSVlanMapEntry ::=
|
|
SEQUENCE {
|
|
fsQoSVlanMapID IndexInteger,
|
|
fsQoSVlanMapIfIndex Unsigned32,
|
|
fsQoSVlanMapVlanId Unsigned32,
|
|
fsQoSVlanMapStatus RowStatus
|
|
}
|
|
|
|
fsQoSVlanMapID OBJECT-TYPE
|
|
SYNTAX IndexInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This object specifies the output VLAN map index for the outgoing packets transmitted over
|
|
egress PORT with specified VLAN-id. This is unique for each entry in
|
|
the VLAN-map table."
|
|
::= { fsQoSVlanMapEntry 1 }
|
|
|
|
|
|
fsQoSVlanMapIfIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Egress Port Number. VLAN based subscriber Queuing/Scheduling
|
|
schema will be created on this port."
|
|
::= { fsQoSVlanMapEntry 2 }
|
|
|
|
fsQoSVlanMapVlanId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object specifies the Vlan Id for Subscriber queue mapping. The Vlan Id should
|
|
already be configured on the switch."
|
|
::= { fsQoSVlanMapEntry 3 }
|
|
|
|
fsQoSVlanMapStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the status of this conceptual row. All writable objects in this
|
|
row may be modified at any time.
|
|
It can be deleted 'destroy', only if it is not referenced
|
|
by other table; otherwise returns inconsistentValue error.
|
|
For any mib table that supports global configurations (less-specific) at runtime
|
|
and H/W supports more-specific configurations, if a more-specific entry is deleted
|
|
by configuration, then the next less-specific entry gets programmed to H/W."
|
|
::= { fsQoSVlanMapEntry 4 }
|
|
|
|
-- ========================================================================== --
|
|
-- PCP MODEL SELECTION --
|
|
-- ========================================================================== --
|
|
|
|
fsQoSPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsQoSPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the table containing Qos related Properties specific to an interface.
|
|
Currently, we are using this table for storing Priority Code Point
|
|
encoding and decoding information."
|
|
::= { fsQoSClass 5 }
|
|
|
|
fsQoSPortEntry OBJECT-TYPE
|
|
SYNTAX FsQoSPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the information controlling per port configuration for Priority Code Point
|
|
Encoding and Decoding."
|
|
INDEX { ifIndex , fsQoSPcpPacketType}
|
|
::= { fsQoSPortTable 1 }
|
|
|
|
FsQoSPortEntry ::=
|
|
SEQUENCE {
|
|
fsQoSPcpPacketType INTEGER,
|
|
fsQoSPcpSelRow INTEGER,
|
|
fsQoSPcpRowStatus RowStatus
|
|
}
|
|
fsQoSPcpPacketType OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
dot1P (0),
|
|
ip (1),
|
|
mpls (3)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the incoming packet type for which Priority Code Point
|
|
Encoding and decoding to be applied."
|
|
::= { fsQoSPortEntry 1 }
|
|
|
|
fsQoSPcpSelRow OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
codePoint8P0D (1),
|
|
codePoint7P1D (2),
|
|
codePoint6P2D (3),
|
|
codePoint5P3D (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the row to be used on this port for PCP encoding and PCP decoding
|
|
tables. PCP encoding and PCP decoding on a port will be based on the row
|
|
configured as per this mib object for this port. This can be set for all
|
|
bride port types."
|
|
|
|
::= { fsQoSPortEntry 2 }
|
|
|
|
|
|
fsQoSPcpRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object spcifies the status of this entry.
|
|
The entry in this table is used when the status of this object
|
|
is SET 'active'. The entry in this table is not used when this
|
|
object is SET 'notInService'."
|
|
::= { fsQoSPortEntry 3 }
|
|
|
|
END
|
|
|