Observium_CE/mibs/adva/ADVA-FSPR7-PM-MIB

20991 lines
642 KiB
Plaintext

-- ***************************************************************************
-- ADVA-FSPR7-PM-MIB.txt
--
-- ADVA AG Optical Networking MIB File
--
-- Copyright 2011 ADVA AG Optical Networking.
--
-- All rights reserved.
-- ***************************************************************************
-- MIB Performance Monitoring definitions required for entity management.
ADVA-FSPR7-PM-MIB DEFINITIONS ::= BEGIN
IMPORTS
DateAndTime,
TruthValue
FROM SNMPv2-TC
OBJECT-TYPE,
MODULE-IDENTITY,
Unsigned32,
Integer32
FROM SNMPv2-SMI
fspR7,
Counter64String
FROM ADVA-MIB
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName,
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
entityTerminPointIndexNo1,
entityTerminPointIndexNo2,
entityTerminPointIndexNo3,
entityTerminPointIndexNo4,
entityTerminPointClassName,
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName
FROM ADVA-FSPR7-MIB;
advaFspR7Pm MODULE-IDENTITY
LAST-UPDATED "201410150000Z"
ORGANIZATION "ADVA Optical Networking"
CONTACT-INFO "EMEA Support
Phone : +49 89 89 0665 848
Fax : +49 89 89 0665 22848
Email : support@advaoptical.com
North American Support
Phone : 886 442 ADVA (2382) (toll-free within the US, Canada and Mexico)
Fax : + 1 806 741 8529 (elsewhere)
Email : support-usa@advaoptical.com
Asia Pacific Support
Phone : + 1 866 442 2382 (other toll-free numbers available in some countries)
Email : support-asia@advaoptical.com"
DESCRIPTION "This is a MIB definition for ADVA AG Optical Networking entity management."
REVISION "201410150000Z"
DESCRIPTION "FSP3000 F7 Release 13.2.2 MIB."
REVISION "201409290000Z"
DESCRIPTION "FSP3000 F7 Release 13.2.1 MIB."
REVISION "201312040000Z"
DESCRIPTION "FSP3000 F7 Release 12.2.1 MIB."
REVISION "201308200000Z"
DESCRIPTION "FSP3000 F7 Release 12.1.1 MIB."
::= { fspR7 11 }
pmEqpt
OBJECT IDENTIFIER ::= { advaFspR7Pm 1 }
pmEqptData
OBJECT IDENTIFIER ::= { pmEqpt 1 }
pmEqptDataThreshold
OBJECT IDENTIFIER ::= { pmEqptData 1 }
pmqpteDataRecord
OBJECT IDENTIFIER ::= { pmEqptData 2 }
pmEqptPhysical
OBJECT IDENTIFIER ::= { pmEqpt 2 }
pmEqptPhysValue
OBJECT IDENTIFIER ::= { pmEqptPhysical 1 }
pmEqptPhysThreshold
OBJECT IDENTIFIER ::= { pmEqptPhysical 2 }
pmEqptPhysRecord
OBJECT IDENTIFIER ::= { pmEqptPhysical 3 }
pmDcn
OBJECT IDENTIFIER ::= { advaFspR7Pm 2 }
pmDcnData
OBJECT IDENTIFIER ::= { pmDcn 1 }
pmDcnDataThreshold
OBJECT IDENTIFIER ::= { pmDcnData 1 }
pmDcnDataRecord
OBJECT IDENTIFIER ::= { pmDcnData 2 }
pmDcnPhysical
OBJECT IDENTIFIER ::= { pmDcn 2 }
pmDcnPhysValue
OBJECT IDENTIFIER ::= { pmDcnPhysical 1 }
pmDcnPhysThreshold
OBJECT IDENTIFIER ::= { pmDcnPhysical 2 }
pmDcnPhysRecord
OBJECT IDENTIFIER ::= { pmDcnPhysical 3 }
pmFacility
OBJECT IDENTIFIER ::= { advaFspR7Pm 7 }
pmFacilityData
OBJECT IDENTIFIER ::= { pmFacility 1 }
pmFacilityDataThreshold
OBJECT IDENTIFIER ::= { pmFacilityData 1 }
pmFacilityDataRecord
OBJECT IDENTIFIER ::= { pmFacilityData 2 }
pmFacilityPhysical
OBJECT IDENTIFIER ::= { pmFacility 2 }
pmFacilityPhysValue
OBJECT IDENTIFIER ::= { pmFacilityPhysical 1 }
pmFacilityPhysThreshold
OBJECT IDENTIFIER ::= { pmFacilityPhysical 2 }
pmFacilityPhysRecord
OBJECT IDENTIFIER ::= { pmFacilityPhysical 3 }
pmTerminPoint
OBJECT IDENTIFIER ::= { advaFspR7Pm 10 }
pmTerminPointData
OBJECT IDENTIFIER ::= { pmTerminPoint 1 }
pmTerminPointDataThreshold
OBJECT IDENTIFIER ::= { pmTerminPointData 1 }
pmTerminPointDataRecord
OBJECT IDENTIFIER ::= { pmTerminPointData 2 }
pmTerminPointPhysical
OBJECT IDENTIFIER ::= { pmTerminPoint 2 }
pmTerminPointPhysValue
OBJECT IDENTIFIER ::= { pmTerminPointPhysical 1 }
pmTerminPointPhysThreshold
OBJECT IDENTIFIER ::= { pmTerminPointPhysical 2 }
pmTerminPointPhysRecord
OBJECT IDENTIFIER ::= { pmTerminPointPhysical 3 }
pmOptMux
OBJECT IDENTIFIER ::= { advaFspR7Pm 17 }
pmOptMuxData
OBJECT IDENTIFIER ::= { pmOptMux 1 }
pmOptMuxDataThreshold
OBJECT IDENTIFIER ::= { pmOptMuxData 1 }
pmOptMuxDataRecord
OBJECT IDENTIFIER ::= { pmOptMuxData 2 }
pmOptMuxPhysical
OBJECT IDENTIFIER ::= { pmOptMux 2 }
pmOptMuxPhysValue
OBJECT IDENTIFIER ::= { pmOptMuxPhysical 1 }
pmOptMuxPhysThreshold
OBJECT IDENTIFIER ::= { pmOptMuxPhysical 2 }
pmOptMuxPhysRecord
OBJECT IDENTIFIER ::= { pmOptMuxPhysical 3 }
eqptPhysInstValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF EqptPhysInstValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmEqptPhysValue 1 }
eqptPhysInstValueEntry OBJECT-TYPE
SYNTAX EqptPhysInstValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName
}
::= { eqptPhysInstValueTable 1 }
EqptPhysInstValueEntry ::= SEQUENCE
{ eqptPhysInstValueWattUp Unsigned32,
eqptPhysInstValueWattOut Unsigned32,
eqptPhysInstValueSubTemp Integer32,
eqptPhysInstValueAmpere Unsigned32,
eqptPhysInstValueTemp Integer32,
eqptPhysInstValuePsuAmpere Unsigned32,
eqptPhysInstValuePsuVoltInp Unsigned32,
eqptPhysInstValueTempExt Integer32,
eqptPhysInstValueMaxOutProt Unsigned32,
eqptPhysInstValuePwrUse Unsigned32,
eqptPhysInstValueMaxOutThres Unsigned32,
eqptPhysInstValueLaserTemp Integer32 }
eqptPhysInstValueWattUp OBJECT-TYPE
SYNTAX Unsigned32
UNITS "W"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sum of the install and/or provisioned equipment maximum power conusmption in the shelf excluding PSUs"
::= { eqptPhysInstValueEntry 1 }
eqptPhysInstValueWattOut OBJECT-TYPE
SYNTAX Unsigned32
UNITS "W"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sum of the PSUs maximum output power in the shelf"
::= { eqptPhysInstValueEntry 2 }
eqptPhysInstValueSubTemp OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Submodule Temperature"
::= { eqptPhysInstValueEntry 3 }
eqptPhysInstValueAmpere OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Instantaneous Current"
::= { eqptPhysInstValueEntry 4 }
eqptPhysInstValueTemp OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Instantaneous Temperature"
::= { eqptPhysInstValueEntry 5 }
eqptPhysInstValuePsuAmpere OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Instantaneous Current"
::= { eqptPhysInstValueEntry 6 }
eqptPhysInstValuePsuVoltInp OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Voltage"
::= { eqptPhysInstValueEntry 7 }
eqptPhysInstValueTempExt OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shelf external ambient temperatur"
::= { eqptPhysInstValueEntry 8 }
eqptPhysInstValueMaxOutProt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "W"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sum of the equipment maximum power that can be protected for PSU failure"
::= { eqptPhysInstValueEntry 9 }
eqptPhysInstValuePwrUse OBJECT-TYPE
SYNTAX Unsigned32
UNITS "W"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Equipment power used"
::= { eqptPhysInstValueEntry 10 }
eqptPhysInstValueMaxOutThres OBJECT-TYPE
SYNTAX Unsigned32
UNITS "W"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sum of the PSUs maximum output power in the shelf minus power of the strongest one (if more than one PSU equipped)."
::= { eqptPhysInstValueEntry 11 }
eqptPhysInstValueLaserTemp OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Temperature"
::= { eqptPhysInstValueEntry 12 }
endOfEqptPhysInstValueTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysValue 2 }
endOfPmEqptPhysValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysValue 10000 }
eqptPhysThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF EqptPhysThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmEqptPhysThreshold 1 }
eqptPhysThresholdEntry OBJECT-TYPE
SYNTAX EqptPhysThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName
}
::= { eqptPhysThresholdTable 1 }
EqptPhysThresholdEntry ::= SEQUENCE
{ eqptPhysThresholdTempHigh Integer32,
eqptPhysThresholdTempLow Integer32,
eqptPhysThresholdAmpHigh Unsigned32,
eqptPhysThresholdSubTempHigh Integer32,
eqptPhysThresholdLaserTempHighThres Integer32,
eqptPhysThresholdLaserTempLowThres Integer32 }
eqptPhysThresholdTempHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board Temperature"
::= { eqptPhysThresholdEntry 1 }
eqptPhysThresholdTempLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board Temperature"
::= { eqptPhysThresholdEntry 2 }
eqptPhysThresholdAmpHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fixed Threshold, read only"
::= { eqptPhysThresholdEntry 3 }
eqptPhysThresholdSubTempHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Submodule High Temperature Threshold"
::= { eqptPhysThresholdEntry 4 }
eqptPhysThresholdLaserTempHighThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser temperature fixed high threshold."
::= { eqptPhysThresholdEntry 5 }
eqptPhysThresholdLaserTempLowThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser temperature fixed low threshold."
::= { eqptPhysThresholdEntry 6 }
endOfEqptPhysThresholdTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysThreshold 2 }
endOfPmEqptPhysThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysThreshold 10000 }
ampEqptHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF AmpEqptHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmEqptPhysRecord 1 }
ampEqptHistorical15minEntry OBJECT-TYPE
SYNTAX AmpEqptHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName,
ampEqptHistorical15minNumber
}
::= { ampEqptHistorical15minTable 1 }
AmpEqptHistorical15minEntry ::= SEQUENCE
{ ampEqptHistorical15minNumber Integer32,
ampEqptHistorical15minLow Unsigned32,
ampEqptHistorical15minMean Unsigned32,
ampEqptHistorical15minHigh Unsigned32,
ampEqptHistorical15minValidFlag TruthValue,
ampEqptHistorical15minTimeStamp DateAndTime }
ampEqptHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { ampEqptHistorical15minEntry 1 }
ampEqptHistorical15minLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board or Pluggable Submodule Low Current"
::= { ampEqptHistorical15minEntry 2 }
ampEqptHistorical15minMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board or Pluggable Submodule Mean Current"
::= { ampEqptHistorical15minEntry 3 }
ampEqptHistorical15minHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board or Pluggable Submodule High Current"
::= { ampEqptHistorical15minEntry 4 }
ampEqptHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { ampEqptHistorical15minEntry 5 }
ampEqptHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { ampEqptHistorical15minEntry 6 }
endOfAmpEqptHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysRecord 2 }
ampEqptHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF AmpEqptHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmEqptPhysRecord 3 }
ampEqptHistorical1dayEntry OBJECT-TYPE
SYNTAX AmpEqptHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName,
ampEqptHistorical1dayNumber
}
::= { ampEqptHistorical1dayTable 1 }
AmpEqptHistorical1dayEntry ::= SEQUENCE
{ ampEqptHistorical1dayNumber Integer32,
ampEqptHistorical1dayLow Unsigned32,
ampEqptHistorical1dayMean Unsigned32,
ampEqptHistorical1dayHigh Unsigned32,
ampEqptHistorical1dayValidFlag TruthValue,
ampEqptHistorical1dayTimeStamp DateAndTime }
ampEqptHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { ampEqptHistorical1dayEntry 1 }
ampEqptHistorical1dayLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board or Pluggable Submodule Low Current"
::= { ampEqptHistorical1dayEntry 2 }
ampEqptHistorical1dayMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board or Pluggable Submodule Mean Current"
::= { ampEqptHistorical1dayEntry 3 }
ampEqptHistorical1dayHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board or Pluggable Submodule High Current"
::= { ampEqptHistorical1dayEntry 4 }
ampEqptHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { ampEqptHistorical1dayEntry 5 }
ampEqptHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { ampEqptHistorical1dayEntry 6 }
endOfAmpEqptHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysRecord 4 }
ampEqptHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF AmpEqptHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmEqptPhysRecord 5 }
ampEqptHistorical1weekEntry OBJECT-TYPE
SYNTAX AmpEqptHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName,
ampEqptHistorical1weekNumber
}
::= { ampEqptHistorical1weekTable 1 }
AmpEqptHistorical1weekEntry ::= SEQUENCE
{ ampEqptHistorical1weekNumber Integer32,
ampEqptHistorical1weekLow Unsigned32,
ampEqptHistorical1weekMean Unsigned32,
ampEqptHistorical1weekHigh Unsigned32,
ampEqptHistorical1weekValidFlag TruthValue,
ampEqptHistorical1weekTimeStamp DateAndTime }
ampEqptHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { ampEqptHistorical1weekEntry 1 }
ampEqptHistorical1weekLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board or Pluggable Submodule Low Current"
::= { ampEqptHistorical1weekEntry 2 }
ampEqptHistorical1weekMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board or Pluggable Submodule Mean Current"
::= { ampEqptHistorical1weekEntry 3 }
ampEqptHistorical1weekHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board or Pluggable Submodule High Current"
::= { ampEqptHistorical1weekEntry 4 }
ampEqptHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { ampEqptHistorical1weekEntry 5 }
ampEqptHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { ampEqptHistorical1weekEntry 6 }
endOfAmpEqptHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysRecord 6 }
ampInEqptHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF AmpInEqptHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmEqptPhysRecord 7 }
ampInEqptHistorical15minEntry OBJECT-TYPE
SYNTAX AmpInEqptHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName,
ampInEqptHistorical15minNumber
}
::= { ampInEqptHistorical15minTable 1 }
AmpInEqptHistorical15minEntry ::= SEQUENCE
{ ampInEqptHistorical15minNumber Integer32,
ampInEqptHistorical15minLow Unsigned32,
ampInEqptHistorical15minMean Unsigned32,
ampInEqptHistorical15minHigh Unsigned32,
ampInEqptHistorical15minValidFlag TruthValue,
ampInEqptHistorical15minTimeStamp DateAndTime }
ampInEqptHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { ampInEqptHistorical15minEntry 1 }
ampInEqptHistorical15minLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Low Current"
::= { ampInEqptHistorical15minEntry 2 }
ampInEqptHistorical15minMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Mean Current"
::= { ampInEqptHistorical15minEntry 3 }
ampInEqptHistorical15minHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input High Current"
::= { ampInEqptHistorical15minEntry 4 }
ampInEqptHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { ampInEqptHistorical15minEntry 5 }
ampInEqptHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { ampInEqptHistorical15minEntry 6 }
endOfAmpInEqptHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysRecord 8 }
ampInEqptHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF AmpInEqptHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmEqptPhysRecord 9 }
ampInEqptHistorical1dayEntry OBJECT-TYPE
SYNTAX AmpInEqptHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName,
ampInEqptHistorical1dayNumber
}
::= { ampInEqptHistorical1dayTable 1 }
AmpInEqptHistorical1dayEntry ::= SEQUENCE
{ ampInEqptHistorical1dayNumber Integer32,
ampInEqptHistorical1dayLow Unsigned32,
ampInEqptHistorical1dayMean Unsigned32,
ampInEqptHistorical1dayHigh Unsigned32,
ampInEqptHistorical1dayValidFlag TruthValue,
ampInEqptHistorical1dayTimeStamp DateAndTime }
ampInEqptHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { ampInEqptHistorical1dayEntry 1 }
ampInEqptHistorical1dayLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Low Current"
::= { ampInEqptHistorical1dayEntry 2 }
ampInEqptHistorical1dayMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Mean Current"
::= { ampInEqptHistorical1dayEntry 3 }
ampInEqptHistorical1dayHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input High Current"
::= { ampInEqptHistorical1dayEntry 4 }
ampInEqptHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { ampInEqptHistorical1dayEntry 5 }
ampInEqptHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { ampInEqptHistorical1dayEntry 6 }
endOfAmpInEqptHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysRecord 10 }
ampInEqptHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF AmpInEqptHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmEqptPhysRecord 11 }
ampInEqptHistorical1weekEntry OBJECT-TYPE
SYNTAX AmpInEqptHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName,
ampInEqptHistorical1weekNumber
}
::= { ampInEqptHistorical1weekTable 1 }
AmpInEqptHistorical1weekEntry ::= SEQUENCE
{ ampInEqptHistorical1weekNumber Integer32,
ampInEqptHistorical1weekLow Unsigned32,
ampInEqptHistorical1weekMean Unsigned32,
ampInEqptHistorical1weekHigh Unsigned32,
ampInEqptHistorical1weekValidFlag TruthValue,
ampInEqptHistorical1weekTimeStamp DateAndTime }
ampInEqptHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { ampInEqptHistorical1weekEntry 1 }
ampInEqptHistorical1weekLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Low Current"
::= { ampInEqptHistorical1weekEntry 2 }
ampInEqptHistorical1weekMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Mean Current"
::= { ampInEqptHistorical1weekEntry 3 }
ampInEqptHistorical1weekHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input High Current"
::= { ampInEqptHistorical1weekEntry 4 }
ampInEqptHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { ampInEqptHistorical1weekEntry 5 }
ampInEqptHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { ampInEqptHistorical1weekEntry 6 }
endOfAmpInEqptHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysRecord 12 }
voltInpEqptHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoltInpEqptHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmEqptPhysRecord 13 }
voltInpEqptHistorical15minEntry OBJECT-TYPE
SYNTAX VoltInpEqptHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName,
voltInpEqptHistorical15minNumber
}
::= { voltInpEqptHistorical15minTable 1 }
VoltInpEqptHistorical15minEntry ::= SEQUENCE
{ voltInpEqptHistorical15minNumber Integer32,
voltInpEqptHistorical15minLow Unsigned32,
voltInpEqptHistorical15minMean Unsigned32,
voltInpEqptHistorical15minHigh Unsigned32,
voltInpEqptHistorical15minValidFlag TruthValue,
voltInpEqptHistorical15minTimeStamp DateAndTime }
voltInpEqptHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { voltInpEqptHistorical15minEntry 1 }
voltInpEqptHistorical15minLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Low Voltage"
::= { voltInpEqptHistorical15minEntry 2 }
voltInpEqptHistorical15minMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Mean Voltage"
::= { voltInpEqptHistorical15minEntry 3 }
voltInpEqptHistorical15minHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input High Voltage"
::= { voltInpEqptHistorical15minEntry 4 }
voltInpEqptHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { voltInpEqptHistorical15minEntry 5 }
voltInpEqptHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { voltInpEqptHistorical15minEntry 6 }
endOfVoltInpEqptHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysRecord 14 }
voltInpEqptHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoltInpEqptHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmEqptPhysRecord 15 }
voltInpEqptHistorical1dayEntry OBJECT-TYPE
SYNTAX VoltInpEqptHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName,
voltInpEqptHistorical1dayNumber
}
::= { voltInpEqptHistorical1dayTable 1 }
VoltInpEqptHistorical1dayEntry ::= SEQUENCE
{ voltInpEqptHistorical1dayNumber Integer32,
voltInpEqptHistorical1dayLow Unsigned32,
voltInpEqptHistorical1dayMean Unsigned32,
voltInpEqptHistorical1dayHigh Unsigned32,
voltInpEqptHistorical1dayValidFlag TruthValue,
voltInpEqptHistorical1dayTimeStamp DateAndTime }
voltInpEqptHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { voltInpEqptHistorical1dayEntry 1 }
voltInpEqptHistorical1dayLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Low Voltage"
::= { voltInpEqptHistorical1dayEntry 2 }
voltInpEqptHistorical1dayMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Mean Voltage"
::= { voltInpEqptHistorical1dayEntry 3 }
voltInpEqptHistorical1dayHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input High Voltage"
::= { voltInpEqptHistorical1dayEntry 4 }
voltInpEqptHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { voltInpEqptHistorical1dayEntry 5 }
voltInpEqptHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { voltInpEqptHistorical1dayEntry 6 }
endOfVoltInpEqptHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysRecord 16 }
voltInpEqptHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoltInpEqptHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmEqptPhysRecord 17 }
voltInpEqptHistorical1weekEntry OBJECT-TYPE
SYNTAX VoltInpEqptHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityEqptShelfNo,
entityEqptSlotNo,
entityEqptPortNo,
entityEqptExtNo,
entityEqptClassName,
voltInpEqptHistorical1weekNumber
}
::= { voltInpEqptHistorical1weekTable 1 }
VoltInpEqptHistorical1weekEntry ::= SEQUENCE
{ voltInpEqptHistorical1weekNumber Integer32,
voltInpEqptHistorical1weekLow Unsigned32,
voltInpEqptHistorical1weekMean Unsigned32,
voltInpEqptHistorical1weekHigh Unsigned32,
voltInpEqptHistorical1weekValidFlag TruthValue,
voltInpEqptHistorical1weekTimeStamp DateAndTime }
voltInpEqptHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { voltInpEqptHistorical1weekEntry 1 }
voltInpEqptHistorical1weekLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Low Voltage"
::= { voltInpEqptHistorical1weekEntry 2 }
voltInpEqptHistorical1weekMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input Mean Voltage"
::= { voltInpEqptHistorical1weekEntry 3 }
voltInpEqptHistorical1weekHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU Input High Voltage"
::= { voltInpEqptHistorical1weekEntry 4 }
voltInpEqptHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { voltInpEqptHistorical1weekEntry 5 }
voltInpEqptHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { voltInpEqptHistorical1weekEntry 6 }
endOfVoltInpEqptHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysRecord 18 }
endOfPmEqptPhysRecord OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmEqptPhysRecord 10000 }
dcnPhysInstValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcnPhysInstValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysValue 1 }
dcnPhysInstValueEntry OBJECT-TYPE
SYNTAX DcnPhysInstValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName
}
::= { dcnPhysInstValueTable 1 }
DcnPhysInstValueEntry ::= SEQUENCE
{ dcnPhysInstValuelbcn Unsigned32,
dcnPhysInstValueOpt Integer32,
dcnPhysInstValueOpr Integer32,
dcnPhysInstValueAtRcv Integer32,
dcnPhysInstValueAttRmt Integer32,
dcnPhysInstValuelbcl Unsigned32 }
dcnPhysInstValuelbcn OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Instantaneous Laser Bias Current Normalized"
::= { dcnPhysInstValueEntry 1 }
dcnPhysInstValueOpt OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Instantaneous Optical Power Transmitted (Output)"
::= { dcnPhysInstValueEntry 2 }
dcnPhysInstValueOpr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Optical Input Power Received"
::= { dcnPhysInstValueEntry 3 }
dcnPhysInstValueAtRcv OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attenuation of Receive Fiber"
::= { dcnPhysInstValueEntry 4 }
dcnPhysInstValueAttRmt OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attenuation of Transmit Fiber"
::= { dcnPhysInstValueEntry 5 }
dcnPhysInstValuelbcl OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Level on demand"
::= { dcnPhysInstValueEntry 6 }
endOfDcnPhysInstValueTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysValue 2 }
endOfPmDcnPhysValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysValue 10000 }
dcnPhysThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcnPhysThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysThreshold 1 }
dcnPhysThresholdEntry OBJECT-TYPE
SYNTAX DcnPhysThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName
}
::= { dcnPhysThresholdTable 1 }
DcnPhysThresholdEntry ::= SEQUENCE
{ dcnPhysThresholdOprLow Integer32,
dcnPhysThresholdOprHigh Integer32,
dcnPhysThresholdOptLow Integer32,
dcnPhysThresholdOptHigh Integer32,
dcnPhysThresholdAttRcvLow Integer32,
dcnPhysThresholdAttRcvHigh Integer32 }
dcnPhysThresholdOprLow OBJECT-TYPE
SYNTAX Integer32 (-450..260 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { dcnPhysThresholdEntry 1 }
dcnPhysThresholdOprHigh OBJECT-TYPE
SYNTAX Integer32 (-450..260 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { dcnPhysThresholdEntry 2 }
dcnPhysThresholdOptLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low fixed threshold of the Optical Power Transmitted (output)"
::= { dcnPhysThresholdEntry 3 }
dcnPhysThresholdOptHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High fixed threshold of the Optical Power Transmitted (output)"
::= { dcnPhysThresholdEntry 4 }
dcnPhysThresholdAttRcvLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low Threshold for Attenuation on Receive Fiber."
::= { dcnPhysThresholdEntry 5 }
dcnPhysThresholdAttRcvHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High Threshold for Attenuation on Receive Fiber"
::= { dcnPhysThresholdEntry 6 }
endOfDcnPhysThresholdTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysThreshold 2 }
endOfPmDcnPhysThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysThreshold 10000 }
optDcnHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptDcnHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 1 }
optDcnHistorical15minEntry OBJECT-TYPE
SYNTAX OptDcnHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
optDcnHistorical15minNumber
}
::= { optDcnHistorical15minTable 1 }
OptDcnHistorical15minEntry ::= SEQUENCE
{ optDcnHistorical15minNumber Integer32,
optDcnHistorical15minLow Integer32,
optDcnHistorical15minMean Integer32,
optDcnHistorical15minHigh Integer32,
optDcnHistorical15minValidFlag TruthValue,
optDcnHistorical15minTimeStamp DateAndTime }
optDcnHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { optDcnHistorical15minEntry 1 }
optDcnHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optDcnHistorical15minEntry 2 }
optDcnHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optDcnHistorical15minEntry 3 }
optDcnHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optDcnHistorical15minEntry 4 }
optDcnHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { optDcnHistorical15minEntry 5 }
optDcnHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { optDcnHistorical15minEntry 6 }
endOfOptDcnHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 2 }
optDcnHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptDcnHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 3 }
optDcnHistorical1dayEntry OBJECT-TYPE
SYNTAX OptDcnHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
optDcnHistorical1dayNumber
}
::= { optDcnHistorical1dayTable 1 }
OptDcnHistorical1dayEntry ::= SEQUENCE
{ optDcnHistorical1dayNumber Integer32,
optDcnHistorical1dayLow Integer32,
optDcnHistorical1dayMean Integer32,
optDcnHistorical1dayHigh Integer32,
optDcnHistorical1dayValidFlag TruthValue,
optDcnHistorical1dayTimeStamp DateAndTime }
optDcnHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { optDcnHistorical1dayEntry 1 }
optDcnHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optDcnHistorical1dayEntry 2 }
optDcnHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optDcnHistorical1dayEntry 3 }
optDcnHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optDcnHistorical1dayEntry 4 }
optDcnHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { optDcnHistorical1dayEntry 5 }
optDcnHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { optDcnHistorical1dayEntry 6 }
endOfOptDcnHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 4 }
optDcnHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptDcnHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 5 }
optDcnHistorical1weekEntry OBJECT-TYPE
SYNTAX OptDcnHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
optDcnHistorical1weekNumber
}
::= { optDcnHistorical1weekTable 1 }
OptDcnHistorical1weekEntry ::= SEQUENCE
{ optDcnHistorical1weekNumber Integer32,
optDcnHistorical1weekLow Integer32,
optDcnHistorical1weekMean Integer32,
optDcnHistorical1weekHigh Integer32,
optDcnHistorical1weekValidFlag TruthValue,
optDcnHistorical1weekTimeStamp DateAndTime }
optDcnHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { optDcnHistorical1weekEntry 1 }
optDcnHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optDcnHistorical1weekEntry 2 }
optDcnHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optDcnHistorical1weekEntry 3 }
optDcnHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optDcnHistorical1weekEntry 4 }
optDcnHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { optDcnHistorical1weekEntry 5 }
optDcnHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { optDcnHistorical1weekEntry 6 }
endOfOptDcnHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 6 }
oprDcnHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OprDcnHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 7 }
oprDcnHistorical15minEntry OBJECT-TYPE
SYNTAX OprDcnHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
oprDcnHistorical15minNumber
}
::= { oprDcnHistorical15minTable 1 }
OprDcnHistorical15minEntry ::= SEQUENCE
{ oprDcnHistorical15minNumber Integer32,
oprDcnHistorical15minLow Integer32,
oprDcnHistorical15minMean Integer32,
oprDcnHistorical15minHigh Integer32,
oprDcnHistorical15minValidFlag TruthValue,
oprDcnHistorical15minTimeStamp DateAndTime }
oprDcnHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { oprDcnHistorical15minEntry 1 }
oprDcnHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprDcnHistorical15minEntry 2 }
oprDcnHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprDcnHistorical15minEntry 3 }
oprDcnHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprDcnHistorical15minEntry 4 }
oprDcnHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oprDcnHistorical15minEntry 5 }
oprDcnHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oprDcnHistorical15minEntry 6 }
endOfOprDcnHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 8 }
oprDcnHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OprDcnHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 9 }
oprDcnHistorical1dayEntry OBJECT-TYPE
SYNTAX OprDcnHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
oprDcnHistorical1dayNumber
}
::= { oprDcnHistorical1dayTable 1 }
OprDcnHistorical1dayEntry ::= SEQUENCE
{ oprDcnHistorical1dayNumber Integer32,
oprDcnHistorical1dayLow Integer32,
oprDcnHistorical1dayMean Integer32,
oprDcnHistorical1dayHigh Integer32,
oprDcnHistorical1dayValidFlag TruthValue,
oprDcnHistorical1dayTimeStamp DateAndTime }
oprDcnHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { oprDcnHistorical1dayEntry 1 }
oprDcnHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprDcnHistorical1dayEntry 2 }
oprDcnHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprDcnHistorical1dayEntry 3 }
oprDcnHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprDcnHistorical1dayEntry 4 }
oprDcnHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oprDcnHistorical1dayEntry 5 }
oprDcnHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oprDcnHistorical1dayEntry 6 }
endOfOprDcnHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 10 }
oprDcnHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF OprDcnHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 11 }
oprDcnHistorical1weekEntry OBJECT-TYPE
SYNTAX OprDcnHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
oprDcnHistorical1weekNumber
}
::= { oprDcnHistorical1weekTable 1 }
OprDcnHistorical1weekEntry ::= SEQUENCE
{ oprDcnHistorical1weekNumber Integer32,
oprDcnHistorical1weekLow Integer32,
oprDcnHistorical1weekMean Integer32,
oprDcnHistorical1weekHigh Integer32,
oprDcnHistorical1weekValidFlag TruthValue,
oprDcnHistorical1weekTimeStamp DateAndTime }
oprDcnHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { oprDcnHistorical1weekEntry 1 }
oprDcnHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprDcnHistorical1weekEntry 2 }
oprDcnHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprDcnHistorical1weekEntry 3 }
oprDcnHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprDcnHistorical1weekEntry 4 }
oprDcnHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oprDcnHistorical1weekEntry 5 }
oprDcnHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oprDcnHistorical1weekEntry 6 }
endOfOprDcnHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 12 }
lbcnDcnHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbcnDcnHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 13 }
lbcnDcnHistorical15minEntry OBJECT-TYPE
SYNTAX LbcnDcnHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
lbcnDcnHistorical15minNumber
}
::= { lbcnDcnHistorical15minTable 1 }
LbcnDcnHistorical15minEntry ::= SEQUENCE
{ lbcnDcnHistorical15minNumber Integer32,
lbcnDcnHistorical15minLow Unsigned32,
lbcnDcnHistorical15minMean Unsigned32,
lbcnDcnHistorical15minHigh Unsigned32,
lbcnDcnHistorical15minValidFlag TruthValue,
lbcnDcnHistorical15minTimeStamp DateAndTime }
lbcnDcnHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { lbcnDcnHistorical15minEntry 1 }
lbcnDcnHistorical15minLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnDcnHistorical15minEntry 2 }
lbcnDcnHistorical15minMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnDcnHistorical15minEntry 3 }
lbcnDcnHistorical15minHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnDcnHistorical15minEntry 4 }
lbcnDcnHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { lbcnDcnHistorical15minEntry 5 }
lbcnDcnHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { lbcnDcnHistorical15minEntry 6 }
endOfLbcnDcnHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 14 }
lbcnDcnHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbcnDcnHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 15 }
lbcnDcnHistorical1dayEntry OBJECT-TYPE
SYNTAX LbcnDcnHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
lbcnDcnHistorical1dayNumber
}
::= { lbcnDcnHistorical1dayTable 1 }
LbcnDcnHistorical1dayEntry ::= SEQUENCE
{ lbcnDcnHistorical1dayNumber Integer32,
lbcnDcnHistorical1dayLow Unsigned32,
lbcnDcnHistorical1dayMean Unsigned32,
lbcnDcnHistorical1dayHigh Unsigned32,
lbcnDcnHistorical1dayValidFlag TruthValue,
lbcnDcnHistorical1dayTimeStamp DateAndTime }
lbcnDcnHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { lbcnDcnHistorical1dayEntry 1 }
lbcnDcnHistorical1dayLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnDcnHistorical1dayEntry 2 }
lbcnDcnHistorical1dayMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnDcnHistorical1dayEntry 3 }
lbcnDcnHistorical1dayHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnDcnHistorical1dayEntry 4 }
lbcnDcnHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { lbcnDcnHistorical1dayEntry 5 }
lbcnDcnHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { lbcnDcnHistorical1dayEntry 6 }
endOfLbcnDcnHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 16 }
lbcnDcnHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbcnDcnHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 17 }
lbcnDcnHistorical1weekEntry OBJECT-TYPE
SYNTAX LbcnDcnHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
lbcnDcnHistorical1weekNumber
}
::= { lbcnDcnHistorical1weekTable 1 }
LbcnDcnHistorical1weekEntry ::= SEQUENCE
{ lbcnDcnHistorical1weekNumber Integer32,
lbcnDcnHistorical1weekLow Unsigned32,
lbcnDcnHistorical1weekMean Unsigned32,
lbcnDcnHistorical1weekHigh Unsigned32,
lbcnDcnHistorical1weekValidFlag TruthValue,
lbcnDcnHistorical1weekTimeStamp DateAndTime }
lbcnDcnHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { lbcnDcnHistorical1weekEntry 1 }
lbcnDcnHistorical1weekLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnDcnHistorical1weekEntry 2 }
lbcnDcnHistorical1weekMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnDcnHistorical1weekEntry 3 }
lbcnDcnHistorical1weekHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnDcnHistorical1weekEntry 4 }
lbcnDcnHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { lbcnDcnHistorical1weekEntry 5 }
lbcnDcnHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { lbcnDcnHistorical1weekEntry 6 }
endOfLbcnDcnHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 18 }
atrcvDcnHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtrcvDcnHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 19 }
atrcvDcnHistorical15minEntry OBJECT-TYPE
SYNTAX AtrcvDcnHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
atrcvDcnHistorical15minNumber
}
::= { atrcvDcnHistorical15minTable 1 }
AtrcvDcnHistorical15minEntry ::= SEQUENCE
{ atrcvDcnHistorical15minNumber Integer32,
atrcvDcnHistorical15minLow Integer32,
atrcvDcnHistorical15minMean Integer32,
atrcvDcnHistorical15minHigh Integer32,
atrcvDcnHistorical15minValidFlag TruthValue,
atrcvDcnHistorical15minTimeStamp DateAndTime }
atrcvDcnHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { atrcvDcnHistorical15minEntry 1 }
atrcvDcnHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Attenuation on Receive Fiber"
::= { atrcvDcnHistorical15minEntry 2 }
atrcvDcnHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mean Attenuation on Receive Fiber"
::= { atrcvDcnHistorical15minEntry 3 }
atrcvDcnHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Attenuation on Receive Fiber"
::= { atrcvDcnHistorical15minEntry 4 }
atrcvDcnHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { atrcvDcnHistorical15minEntry 5 }
atrcvDcnHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { atrcvDcnHistorical15minEntry 6 }
endOfAtrcvDcnHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 20 }
atrcvDcnHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtrcvDcnHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 21 }
atrcvDcnHistorical1dayEntry OBJECT-TYPE
SYNTAX AtrcvDcnHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
atrcvDcnHistorical1dayNumber
}
::= { atrcvDcnHistorical1dayTable 1 }
AtrcvDcnHistorical1dayEntry ::= SEQUENCE
{ atrcvDcnHistorical1dayNumber Integer32,
atrcvDcnHistorical1dayLow Integer32,
atrcvDcnHistorical1dayMean Integer32,
atrcvDcnHistorical1dayHigh Integer32,
atrcvDcnHistorical1dayValidFlag TruthValue,
atrcvDcnHistorical1dayTimeStamp DateAndTime }
atrcvDcnHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { atrcvDcnHistorical1dayEntry 1 }
atrcvDcnHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Attenuation on Receive Fiber"
::= { atrcvDcnHistorical1dayEntry 2 }
atrcvDcnHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mean Attenuation on Receive Fiber"
::= { atrcvDcnHistorical1dayEntry 3 }
atrcvDcnHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Attenuation on Receive Fiber"
::= { atrcvDcnHistorical1dayEntry 4 }
atrcvDcnHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { atrcvDcnHistorical1dayEntry 5 }
atrcvDcnHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { atrcvDcnHistorical1dayEntry 6 }
endOfAtrcvDcnHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 22 }
atrcvDcnHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtrcvDcnHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmDcnPhysRecord 23 }
atrcvDcnHistorical1weekEntry OBJECT-TYPE
SYNTAX AtrcvDcnHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
atrcvDcnHistorical1weekNumber
}
::= { atrcvDcnHistorical1weekTable 1 }
AtrcvDcnHistorical1weekEntry ::= SEQUENCE
{ atrcvDcnHistorical1weekNumber Integer32,
atrcvDcnHistorical1weekLow Integer32,
atrcvDcnHistorical1weekMean Integer32,
atrcvDcnHistorical1weekHigh Integer32,
atrcvDcnHistorical1weekValidFlag TruthValue,
atrcvDcnHistorical1weekTimeStamp DateAndTime }
atrcvDcnHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { atrcvDcnHistorical1weekEntry 1 }
atrcvDcnHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Attenuation on Receive Fiber"
::= { atrcvDcnHistorical1weekEntry 2 }
atrcvDcnHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mean Attenuation on Receive Fiber"
::= { atrcvDcnHistorical1weekEntry 3 }
atrcvDcnHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Attenuation on Receive Fiber"
::= { atrcvDcnHistorical1weekEntry 4 }
atrcvDcnHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { atrcvDcnHistorical1weekEntry 5 }
atrcvDcnHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { atrcvDcnHistorical1weekEntry 6 }
endOfAtrcvDcnHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 24 }
endOfPmDcnPhysRecord OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmDcnPhysRecord 10000 }
facilityDataThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF FacilityDataThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataThreshold 1 }
facilityDataThresholdEntry OBJECT-TYPE
SYNTAX FacilityDataThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { facilityDataThresholdTable 1 }
FacilityDataThresholdEntry ::= SEQUENCE
{ facilityDataThresholdESOduHT15min Unsigned32,
facilityDataThresholdESOduHT1day Unsigned32,
facilityDataThresholdSESOduHT15min Unsigned32,
facilityDataThresholdSESOduHT1day Unsigned32,
facilityDataThresholdBBEOduHT15min Counter64String,
facilityDataThresholdBBEOduHT1day Counter64String,
facilityDataThresholdUASOduHT15min Unsigned32,
facilityDataThresholdUASOduHT1day Unsigned32,
facilityDataThresholdESTcmaHT15min Unsigned32,
facilityDataThresholdESTcmaHT1day Unsigned32,
facilityDataThresholdSESTcmaHT15min Unsigned32,
facilityDataThresholdSESTcmaHT1day Unsigned32,
facilityDataThresholdBBETcmaHT15min Counter64String,
facilityDataThresholdBBETcmaHT1day Counter64String,
facilityDataThresholdUASTcmaHT15min Unsigned32,
facilityDataThresholdUASTcmaHT1day Unsigned32,
facilityDataThresholdESTcmbHT15min Unsigned32,
facilityDataThresholdESTcmbHT1day Unsigned32,
facilityDataThresholdSESTcmbHT15min Unsigned32,
facilityDataThresholdSESTcmbHT1day Unsigned32,
facilityDataThresholdBBETcmbHT15min Counter64String,
facilityDataThresholdBBETcmbHT1day Counter64String,
facilityDataThresholdUASTcmbHT15min Unsigned32,
facilityDataThresholdUASTcmbHT1day Unsigned32,
facilityDataThresholdESTcmcHT15min Unsigned32,
facilityDataThresholdESTcmcHT1day Unsigned32,
facilityDataThresholdSESTcmcHT15min Unsigned32,
facilityDataThresholdSESTcmcHT1day Unsigned32,
facilityDataThresholdBBETcmcHT15min Counter64String,
facilityDataThresholdBBETcmcHT1day Counter64String,
facilityDataThresholdUASTcmcHT15min Unsigned32,
facilityDataThresholdUASTcmcHT1day Unsigned32,
facilityDataThresholdESOtuHT15min Unsigned32,
facilityDataThresholdESOtuHT1day Unsigned32,
facilityDataThresholdSESOtuHT15min Unsigned32,
facilityDataThresholdSESOtuHT1day Unsigned32,
facilityDataThresholdBBEOtuHT15min Counter64String,
facilityDataThresholdBBEOtuHT1day Counter64String,
facilityDataThresholdUASOtuHT15min Unsigned32,
facilityDataThresholdUASOtuHT1day Unsigned32,
facilityDataThresholdESFecHT15min Unsigned32,
facilityDataThresholdESFecHT1day Unsigned32,
facilityDataThresholdSESFecHT15min Unsigned32,
facilityDataThresholdSESFecHT1day Unsigned32,
facilityDataThresholdUBEFecHT15min Counter64String,
facilityDataThresholdUBEFecHT1day Counter64String,
facilityDataThresholdCEFecHT15min Counter64String,
facilityDataThresholdCEFecHT1day Counter64String,
facilityDataThresholdBERCEFecHT15min Counter64String,
facilityDataThresholdBERCEFecHT1day Counter64String,
facilityDataThresholdESPcsHT15min Unsigned32,
facilityDataThresholdESPcsHT1day Unsigned32,
facilityDataThresholdDEPcsHT15min Unsigned32,
facilityDataThresholdDEPcsHT1day Unsigned32,
facilityDataThresholdCVPcsHT15min Counter64String,
facilityDataThresholdCVPcsHT1day Counter64String,
facilityDataThresholdESLHT15min Unsigned32,
facilityDataThresholdESLHT1day Unsigned32,
facilityDataThresholdSESLHT15min Unsigned32,
facilityDataThresholdSESLHT1day Unsigned32,
facilityDataThresholdUASLHT15min Unsigned32,
facilityDataThresholdUASLHT1day Unsigned32,
facilityDataThresholdCVLHT15min Counter64String,
facilityDataThresholdCVLHT1day Counter64String,
facilityDataThresholdESSHT15min Unsigned32,
facilityDataThresholdESSHT1day Unsigned32,
facilityDataThresholdSESSHT15min Unsigned32,
facilityDataThresholdSESSHT1day Unsigned32,
facilityDataThresholdSEFSSHT15min Unsigned32,
facilityDataThresholdSEFSSHT1day Unsigned32,
facilityDataThresholdCVSHT15min Counter64String,
facilityDataThresholdCVSHT1day Counter64String,
facilityDataThresholdBBEPcsHT15min Counter64String,
facilityDataThresholdBBEPcsHT1day Counter64String }
facilityDataThresholdESOduHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 1 }
facilityDataThresholdESOduHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 2 }
facilityDataThresholdSESOduHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Severely Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 3 }
facilityDataThresholdSESOduHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Severely Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 4 }
facilityDataThresholdBBEOduHT15min OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Background Block Errors 15 Minute Threshold"
::= { facilityDataThresholdEntry 5 }
facilityDataThresholdBBEOduHT1day OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Background Block Errors 1 Day Threshold"
::= { facilityDataThresholdEntry 6 }
facilityDataThresholdUASOduHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Unavailable Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 7 }
facilityDataThresholdUASOduHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Unavailable Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 8 }
facilityDataThresholdESTcmaHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 9 }
facilityDataThresholdESTcmaHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 10 }
facilityDataThresholdSESTcmaHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tandem Connection Monitor A Section Severely Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 11 }
facilityDataThresholdSESTcmaHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tandem Connection Monitor A Section Severely Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 12 }
facilityDataThresholdBBETcmaHT15min OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection A Background Block Errors 15 Minute Threshold"
::= { facilityDataThresholdEntry 13 }
facilityDataThresholdBBETcmaHT1day OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection A Background Block Errors 1 Day Minute Threshold"
::= { facilityDataThresholdEntry 14 }
facilityDataThresholdUASTcmaHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Unavailable Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 15 }
facilityDataThresholdUASTcmaHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Unavailable Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 16 }
facilityDataThresholdESTcmbHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 17 }
facilityDataThresholdESTcmbHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 18 }
facilityDataThresholdSESTcmbHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tandem Connection Monitor B Section Severely Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 19 }
facilityDataThresholdSESTcmbHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tandem Connection Monitor B Section Severely Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 20 }
facilityDataThresholdBBETcmbHT15min OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection B Background Block Errors 15 Minute Threshold"
::= { facilityDataThresholdEntry 21 }
facilityDataThresholdBBETcmbHT1day OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection B Background Block Errors 1 Day Threshold"
::= { facilityDataThresholdEntry 22 }
facilityDataThresholdUASTcmbHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Unavailable Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 23 }
facilityDataThresholdUASTcmbHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Unavailable Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 24 }
facilityDataThresholdESTcmcHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 25 }
facilityDataThresholdESTcmcHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 26 }
facilityDataThresholdSESTcmcHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tandem Connection Monitor C Section Severely Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 27 }
facilityDataThresholdSESTcmcHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tandem Connection Monitor C Section Severely Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 28 }
facilityDataThresholdBBETcmcHT15min OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection C Background Block Errors 15 Minute Threshold"
::= { facilityDataThresholdEntry 29 }
facilityDataThresholdBBETcmcHT1day OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection C Background Block Errors 1 Day Threshold"
::= { facilityDataThresholdEntry 30 }
facilityDataThresholdUASTcmcHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Unavailable Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 31 }
facilityDataThresholdUASTcmcHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Unavailable Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 32 }
facilityDataThresholdESOtuHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 33 }
facilityDataThresholdESOtuHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 34 }
facilityDataThresholdSESOtuHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU Severely Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 35 }
facilityDataThresholdSESOtuHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU Severely Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 36 }
facilityDataThresholdBBEOtuHT15min OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU Background Block Errors 15 Minute Threshold"
::= { facilityDataThresholdEntry 37 }
facilityDataThresholdBBEOtuHT1day OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU Background Block Errors 1 Day Threshold"
::= { facilityDataThresholdEntry 38 }
facilityDataThresholdUASOtuHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU Unavailable Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 39 }
facilityDataThresholdUASOtuHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU Unavailable Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 40 }
facilityDataThresholdESFecHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU FEC Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 41 }
facilityDataThresholdESFecHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU FEC Errored Seconds Day Threshold"
::= { facilityDataThresholdEntry 42 }
facilityDataThresholdSESFecHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU FEC Severely Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 43 }
facilityDataThresholdSESFecHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OTU FEC Severely Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 44 }
facilityDataThresholdUBEFecHT15min OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Uncorrected Block Errors 15 Minute Threshold"
::= { facilityDataThresholdEntry 45 }
facilityDataThresholdUBEFecHT1day OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Uncorrected Block Errors 1 Day Threshold"
::= { facilityDataThresholdEntry 46 }
facilityDataThresholdCEFecHT15min OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"FEC Corrected Errors 15 Minute Threshold"
::= { facilityDataThresholdEntry 47 }
facilityDataThresholdCEFecHT1day OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"FEC Corrected Errors 1 Day Threshold"
::= { facilityDataThresholdEntry 48 }
facilityDataThresholdBERCEFecHT15min OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-18"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bit Error Rate before FEC 15 Minute Threshold"
::= { facilityDataThresholdEntry 49 }
facilityDataThresholdBERCEFecHT1day OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-18"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bit Error Rate before FEC 1 Day Threshold"
::= { facilityDataThresholdEntry 50 }
facilityDataThresholdESPcsHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 51 }
facilityDataThresholdESPcsHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..89400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 52 }
facilityDataThresholdDEPcsHT15min OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Physical Coding Layer Disparity Errors 15 Minute Threshold"
::= { facilityDataThresholdEntry 53 }
facilityDataThresholdDEPcsHT1day OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Physical Coding Layer Disparity Errors 1 Day Threshold"
::= { facilityDataThresholdEntry 54 }
facilityDataThresholdCVPcsHT15min OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Physical Coding Layer 15 Minute Threshold"
::= { facilityDataThresholdEntry 55 }
facilityDataThresholdCVPcsHT1day OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations 1 Day Threshold"
::= { facilityDataThresholdEntry 56 }
facilityDataThresholdESLHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line / Multiplex Section Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 57 }
facilityDataThresholdESLHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line / Multiplex Section Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 58 }
facilityDataThresholdSESLHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line / Multiplex Section Severely Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 59 }
facilityDataThresholdSESLHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line / Multiplex Section Severely Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 60 }
facilityDataThresholdUASLHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line / Multiplex Section Unavailable Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 61 }
facilityDataThresholdUASLHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line / Multiplex Section Unavailable Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 62 }
facilityDataThresholdCVLHT15min OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line / Multiplex Section Coding Violations 15 Minute Threshold"
::= { facilityDataThresholdEntry 63 }
facilityDataThresholdCVLHT1day OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line / Multiplex Section Coding Violations 1 Day Threshold"
::= { facilityDataThresholdEntry 64 }
facilityDataThresholdESSHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Section / Regeneration Section Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 65 }
facilityDataThresholdESSHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Section / Regeneration Section Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 66 }
facilityDataThresholdSESSHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Section / Regenerator Section Severely Errored Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 67 }
facilityDataThresholdSESSHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Section / Regenerator Section Severely Errored Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 68 }
facilityDataThresholdSEFSSHT15min OBJECT-TYPE
SYNTAX Unsigned32 (0..900 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Section Severely Errored Frame Seconds 15 Minute Threshold"
::= { facilityDataThresholdEntry 69 }
facilityDataThresholdSEFSSHT1day OBJECT-TYPE
SYNTAX Unsigned32 (0..86400 | 4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Section Severely Errored Frame Seconds 1 Day Threshold"
::= { facilityDataThresholdEntry 70 }
facilityDataThresholdCVSHT15min OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Section / Regenerator Section Coding Violations 15 Minute Threshold"
::= { facilityDataThresholdEntry 71 }
facilityDataThresholdCVSHT1day OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Section / Regenerator Section Coding Violations 1 Day Threshold"
::= { facilityDataThresholdEntry 72 }
facilityDataThresholdBBEPcsHT15min OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PCS Background Block Errors 15 Minute Threshold"
::= { facilityDataThresholdEntry 73 }
facilityDataThresholdBBEPcsHT1day OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PCS Background Block Errors 1 Day Threshold"
::= { facilityDataThresholdEntry 74 }
endOfFacilityDataThresholdTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataThreshold 2 }
endOfPmFacilityDataThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataThreshold 10000 }
oduFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OduFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 1 }
oduFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX OduFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { oduFacilityCurrent15minTable 1 }
OduFacilityCurrent15minEntry ::= SEQUENCE
{ oduFacilityCurrent15minES Unsigned32,
oduFacilityCurrent15minSES Unsigned32,
oduFacilityCurrent15minBbe Counter64String,
oduFacilityCurrent15minUAS Unsigned32,
oduFacilityCurrent15minElapsedTime Integer32 }
oduFacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Errored Seconds"
::= { oduFacilityCurrent15minEntry 1 }
oduFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Severely Errored Seconds"
::= { oduFacilityCurrent15minEntry 2 }
oduFacilityCurrent15minBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Background Block Errors"
::= { oduFacilityCurrent15minEntry 3 }
oduFacilityCurrent15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Unavailable Seconds"
::= { oduFacilityCurrent15minEntry 4 }
oduFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { oduFacilityCurrent15minEntry 5 }
endOfOduFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 2 }
oduFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OduFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 3 }
oduFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX OduFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { oduFacilityCurrent1dayTable 1 }
OduFacilityCurrent1dayEntry ::= SEQUENCE
{ oduFacilityCurrent1dayES Unsigned32,
oduFacilityCurrent1daySES Unsigned32,
oduFacilityCurrent1dayBbe Counter64String,
oduFacilityCurrent1dayUAS Unsigned32,
oduFacilityCurrent1dayElapsedTime Integer32 }
oduFacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Errored Seconds"
::= { oduFacilityCurrent1dayEntry 1 }
oduFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Severely Errored Seconds"
::= { oduFacilityCurrent1dayEntry 2 }
oduFacilityCurrent1dayBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Background Block Errors"
::= { oduFacilityCurrent1dayEntry 3 }
oduFacilityCurrent1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Unavailable Seconds"
::= { oduFacilityCurrent1dayEntry 4 }
oduFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { oduFacilityCurrent1dayEntry 5 }
endOfOduFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 4 }
oduFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OduFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 5 }
oduFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX OduFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
oduFacilityHistorical15minNumber
}
::= { oduFacilityHistorical15minTable 1 }
OduFacilityHistorical15minEntry ::= SEQUENCE
{ oduFacilityHistorical15minNumber Integer32,
oduFacilityHistorical15minES Unsigned32,
oduFacilityHistorical15minSES Unsigned32,
oduFacilityHistorical15minBbe Counter64String,
oduFacilityHistorical15minUAS Unsigned32,
oduFacilityHistorical15minValidFlag TruthValue,
oduFacilityHistorical15minTimeStamp DateAndTime }
oduFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { oduFacilityHistorical15minEntry 1 }
oduFacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Errored Seconds"
::= { oduFacilityHistorical15minEntry 2 }
oduFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Severely Errored Seconds"
::= { oduFacilityHistorical15minEntry 3 }
oduFacilityHistorical15minBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Background Block Errors"
::= { oduFacilityHistorical15minEntry 4 }
oduFacilityHistorical15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Unavailable Seconds"
::= { oduFacilityHistorical15minEntry 5 }
oduFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oduFacilityHistorical15minEntry 6 }
oduFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oduFacilityHistorical15minEntry 7 }
endOfOduFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 6 }
oduFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OduFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 7 }
oduFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX OduFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
oduFacilityHistorical1dayNumber
}
::= { oduFacilityHistorical1dayTable 1 }
OduFacilityHistorical1dayEntry ::= SEQUENCE
{ oduFacilityHistorical1dayNumber Integer32,
oduFacilityHistorical1dayES Unsigned32,
oduFacilityHistorical1daySES Unsigned32,
oduFacilityHistorical1dayBbe Counter64String,
oduFacilityHistorical1dayUAS Unsigned32,
oduFacilityHistorical1dayValidFlag TruthValue,
oduFacilityHistorical1dayTimeStamp DateAndTime }
oduFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { oduFacilityHistorical1dayEntry 1 }
oduFacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Errored Seconds"
::= { oduFacilityHistorical1dayEntry 2 }
oduFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Severely Errored Seconds"
::= { oduFacilityHistorical1dayEntry 3 }
oduFacilityHistorical1dayBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Background Block Errors"
::= { oduFacilityHistorical1dayEntry 4 }
oduFacilityHistorical1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Unavailable Seconds"
::= { oduFacilityHistorical1dayEntry 5 }
oduFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oduFacilityHistorical1dayEntry 6 }
oduFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oduFacilityHistorical1dayEntry 7 }
endOfOduFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 8 }
tcmAFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmAFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 9 }
tcmAFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX TcmAFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { tcmAFacilityCurrent15minTable 1 }
TcmAFacilityCurrent15minEntry ::= SEQUENCE
{ tcmAFacilityCurrent15minES Unsigned32,
tcmAFacilityCurrent15minSES Unsigned32,
tcmAFacilityCurrent15minBbe Counter64String,
tcmAFacilityCurrent15minUAS Unsigned32,
tcmAFacilityCurrent15minElapsedTime Integer32 }
tcmAFacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Errored Seconds"
::= { tcmAFacilityCurrent15minEntry 1 }
tcmAFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Severely Errored Seconds"
::= { tcmAFacilityCurrent15minEntry 2 }
tcmAFacilityCurrent15minBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Background Block Errors"
::= { tcmAFacilityCurrent15minEntry 3 }
tcmAFacilityCurrent15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Unavailable Seconds"
::= { tcmAFacilityCurrent15minEntry 4 }
tcmAFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { tcmAFacilityCurrent15minEntry 5 }
endOfTcmAFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 10 }
tcmAFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmAFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 11 }
tcmAFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX TcmAFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { tcmAFacilityCurrent1dayTable 1 }
TcmAFacilityCurrent1dayEntry ::= SEQUENCE
{ tcmAFacilityCurrent1dayES Unsigned32,
tcmAFacilityCurrent1daySES Unsigned32,
tcmAFacilityCurrent1dayBbe Counter64String,
tcmAFacilityCurrent1dayUAS Unsigned32,
tcmAFacilityCurrent1dayElapsedTime Integer32 }
tcmAFacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Errored Seconds"
::= { tcmAFacilityCurrent1dayEntry 1 }
tcmAFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Severely Errored Seconds"
::= { tcmAFacilityCurrent1dayEntry 2 }
tcmAFacilityCurrent1dayBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Background Block Errors"
::= { tcmAFacilityCurrent1dayEntry 3 }
tcmAFacilityCurrent1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Unavailable Seconds"
::= { tcmAFacilityCurrent1dayEntry 4 }
tcmAFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { tcmAFacilityCurrent1dayEntry 5 }
endOfTcmAFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 12 }
tcmAFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmAFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 13 }
tcmAFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX TcmAFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
tcmAFacilityHistorical15minNumber
}
::= { tcmAFacilityHistorical15minTable 1 }
TcmAFacilityHistorical15minEntry ::= SEQUENCE
{ tcmAFacilityHistorical15minNumber Integer32,
tcmAFacilityHistorical15minES Unsigned32,
tcmAFacilityHistorical15minSES Unsigned32,
tcmAFacilityHistorical15minBbe Counter64String,
tcmAFacilityHistorical15minUAS Unsigned32,
tcmAFacilityHistorical15minValidFlag TruthValue,
tcmAFacilityHistorical15minTimeStamp DateAndTime }
tcmAFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { tcmAFacilityHistorical15minEntry 1 }
tcmAFacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Errored Seconds"
::= { tcmAFacilityHistorical15minEntry 2 }
tcmAFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Severely Errored Seconds"
::= { tcmAFacilityHistorical15minEntry 3 }
tcmAFacilityHistorical15minBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Background Block Errors"
::= { tcmAFacilityHistorical15minEntry 4 }
tcmAFacilityHistorical15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Unavailable Seconds"
::= { tcmAFacilityHistorical15minEntry 5 }
tcmAFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { tcmAFacilityHistorical15minEntry 6 }
tcmAFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { tcmAFacilityHistorical15minEntry 7 }
endOfTcmAFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 14 }
tcmAFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmAFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 15 }
tcmAFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX TcmAFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
oduFacilityHistorical1dayNumber
}
::= { tcmAFacilityHistorical1dayTable 1 }
TcmAFacilityHistorical1dayEntry ::= SEQUENCE
{ tcmAFacilityHistorical1dayNumber Integer32,
tcmAFacilityHistorical1dayES Unsigned32,
tcmAFacilityHistorical1daySES Unsigned32,
tcmAFacilityHistorical1dayBbe Counter64String,
tcmAFacilityHistorical1dayUAS Unsigned32,
tcmAFacilityHistorical1dayValidFlag TruthValue,
tcmAFacilityHistorical1dayTimeStamp DateAndTime }
tcmAFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { tcmAFacilityHistorical1dayEntry 1 }
tcmAFacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Errored Seconds"
::= { tcmAFacilityHistorical1dayEntry 2 }
tcmAFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Severely Errored Seconds"
::= { tcmAFacilityHistorical1dayEntry 3 }
tcmAFacilityHistorical1dayBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Background Block Errors"
::= { tcmAFacilityHistorical1dayEntry 4 }
tcmAFacilityHistorical1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring A Unavailable Seconds"
::= { tcmAFacilityHistorical1dayEntry 5 }
tcmAFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { tcmAFacilityHistorical1dayEntry 6 }
tcmAFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { tcmAFacilityHistorical1dayEntry 7 }
endOfTcmAFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 16 }
tcmBFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmBFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 17 }
tcmBFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX TcmBFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { tcmBFacilityCurrent15minTable 1 }
TcmBFacilityCurrent15minEntry ::= SEQUENCE
{ tcmBFacilityCurrent15minES Unsigned32,
tcmBFacilityCurrent15minSES Unsigned32,
tcmBFacilityCurrent15minBbe Counter64String,
tcmBFacilityCurrent15minUAS Unsigned32,
tcmBFacilityCurrent15minElapsedTime Integer32 }
tcmBFacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Errored Seconds"
::= { tcmBFacilityCurrent15minEntry 1 }
tcmBFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Severely Errored Seconds"
::= { tcmBFacilityCurrent15minEntry 2 }
tcmBFacilityCurrent15minBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Background Block Errors"
::= { tcmBFacilityCurrent15minEntry 3 }
tcmBFacilityCurrent15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Unavailable Seconds"
::= { tcmBFacilityCurrent15minEntry 4 }
tcmBFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { tcmBFacilityCurrent15minEntry 5 }
endOfTcmBFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 18 }
tcmBFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmBFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 19 }
tcmBFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX TcmBFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { tcmBFacilityCurrent1dayTable 1 }
TcmBFacilityCurrent1dayEntry ::= SEQUENCE
{ tcmBFacilityCurrent1dayES Unsigned32,
tcmBFacilityCurrent1daySES Unsigned32,
tcmBFacilityCurrent1dayBbe Counter64String,
tcmBFacilityCurrent1dayUAS Unsigned32,
tcmBFacilityCurrent1dayElapsedTime Integer32 }
tcmBFacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Errored Seconds"
::= { tcmBFacilityCurrent1dayEntry 1 }
tcmBFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Severely Errored Seconds"
::= { tcmBFacilityCurrent1dayEntry 2 }
tcmBFacilityCurrent1dayBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Background Block Errors"
::= { tcmBFacilityCurrent1dayEntry 3 }
tcmBFacilityCurrent1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Unavailable Seconds"
::= { tcmBFacilityCurrent1dayEntry 4 }
tcmBFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { tcmBFacilityCurrent1dayEntry 5 }
endOfTcmBFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 20 }
tcmBFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmBFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 21 }
tcmBFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX TcmBFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
tcmBFacilityHistorical15minNumber
}
::= { tcmBFacilityHistorical15minTable 1 }
TcmBFacilityHistorical15minEntry ::= SEQUENCE
{ tcmBFacilityHistorical15minNumber Integer32,
tcmBFacilityHistorical15minES Unsigned32,
tcmBFacilityHistorical15minSES Unsigned32,
tcmBFacilityHistorical15minBbe Counter64String,
tcmBFacilityHistorical15minUAS Unsigned32,
tcmBFacilityHistorical15minValidFlag TruthValue,
tcmBFacilityHistorical15minTimeStamp DateAndTime }
tcmBFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { tcmBFacilityHistorical15minEntry 1 }
tcmBFacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Errored Seconds"
::= { tcmBFacilityHistorical15minEntry 2 }
tcmBFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Severely Errored Seconds"
::= { tcmBFacilityHistorical15minEntry 3 }
tcmBFacilityHistorical15minBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Background Block Errors"
::= { tcmBFacilityHistorical15minEntry 4 }
tcmBFacilityHistorical15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Unavailable Seconds"
::= { tcmBFacilityHistorical15minEntry 5 }
tcmBFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { tcmBFacilityHistorical15minEntry 6 }
tcmBFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { tcmBFacilityHistorical15minEntry 7 }
endOfTcmBFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 22 }
tcmBFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmBFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 23 }
tcmBFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX TcmBFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
tcmBFacilityHistorical1dayNumber
}
::= { tcmBFacilityHistorical1dayTable 1 }
TcmBFacilityHistorical1dayEntry ::= SEQUENCE
{ tcmBFacilityHistorical1dayNumber Integer32,
tcmBFacilityHistorical1dayES Unsigned32,
tcmBFacilityHistorical1daySES Unsigned32,
tcmBFacilityHistorical1dayBbe Counter64String,
tcmBFacilityHistorical1dayUAS Unsigned32,
tcmBFacilityHistorical1dayValidFlag TruthValue,
tcmBFacilityHistorical1dayTimeStamp DateAndTime }
tcmBFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { tcmBFacilityHistorical1dayEntry 1 }
tcmBFacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Errored Seconds"
::= { tcmBFacilityHistorical1dayEntry 2 }
tcmBFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Severely Errored Seconds"
::= { tcmBFacilityHistorical1dayEntry 3 }
tcmBFacilityHistorical1dayBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Background Block Errors"
::= { tcmBFacilityHistorical1dayEntry 4 }
tcmBFacilityHistorical1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring B Unavailable Seconds"
::= { tcmBFacilityHistorical1dayEntry 5 }
tcmBFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { tcmBFacilityHistorical1dayEntry 6 }
tcmBFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { tcmBFacilityHistorical1dayEntry 7 }
endOfTcmBFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 24 }
tcmCFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmCFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 25 }
tcmCFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX TcmCFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { tcmCFacilityCurrent15minTable 1 }
TcmCFacilityCurrent15minEntry ::= SEQUENCE
{ tcmCFacilityCurrent15minES Unsigned32,
tcmCFacilityCurrent15minSES Unsigned32,
tcmCFacilityCurrent15minBbe Counter64String,
tcmCFacilityCurrent15minUAS Unsigned32,
tcmCFacilityCurrent15minElapsedTime Integer32 }
tcmCFacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Errored Seconds"
::= { tcmCFacilityCurrent15minEntry 1 }
tcmCFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Severely Errored Seconds"
::= { tcmCFacilityCurrent15minEntry 2 }
tcmCFacilityCurrent15minBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Background Block Errors"
::= { tcmCFacilityCurrent15minEntry 3 }
tcmCFacilityCurrent15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Unavailable Seconds"
::= { tcmCFacilityCurrent15minEntry 4 }
tcmCFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { tcmCFacilityCurrent15minEntry 5 }
endOfTcmCFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 26 }
tcmCFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmCFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 27 }
tcmCFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX TcmCFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { tcmCFacilityCurrent1dayTable 1 }
TcmCFacilityCurrent1dayEntry ::= SEQUENCE
{ tcmCFacilityCurrent1dayES Unsigned32,
tcmCFacilityCurrent1daySES Unsigned32,
tcmCFacilityCurrent1dayBbe Counter64String,
tcmCFacilityCurrent1dayUAS Unsigned32,
tcmCFacilityCurrent1dayElapsedTime Integer32 }
tcmCFacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Errored Seconds"
::= { tcmCFacilityCurrent1dayEntry 1 }
tcmCFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Severely Errored Seconds"
::= { tcmCFacilityCurrent1dayEntry 2 }
tcmCFacilityCurrent1dayBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Background Block Errors"
::= { tcmCFacilityCurrent1dayEntry 3 }
tcmCFacilityCurrent1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Unavailable Seconds"
::= { tcmCFacilityCurrent1dayEntry 4 }
tcmCFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { tcmCFacilityCurrent1dayEntry 5 }
endOfTcmCFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 28 }
tcmCFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmCFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 29 }
tcmCFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX TcmCFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
tcmCFacilityHistorical15minNumber
}
::= { tcmCFacilityHistorical15minTable 1 }
TcmCFacilityHistorical15minEntry ::= SEQUENCE
{ tcmCFacilityHistorical15minNumber Integer32,
tcmCFacilityHistorical15minES Unsigned32,
tcmCFacilityHistorical15minSES Unsigned32,
tcmCFacilityHistorical15minBbe Counter64String,
tcmCFacilityHistorical15minUAS Unsigned32,
tcmCFacilityHistorical15minValidFlag TruthValue,
tcmCFacilityHistorical15minTimeStamp DateAndTime }
tcmCFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { tcmCFacilityHistorical15minEntry 1 }
tcmCFacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Errored Seconds"
::= { tcmCFacilityHistorical15minEntry 2 }
tcmCFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Severely Errored Seconds"
::= { tcmCFacilityHistorical15minEntry 3 }
tcmCFacilityHistorical15minBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Background Block Errors"
::= { tcmCFacilityHistorical15minEntry 4 }
tcmCFacilityHistorical15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Unavailable Seconds"
::= { tcmCFacilityHistorical15minEntry 5 }
tcmCFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { tcmCFacilityHistorical15minEntry 6 }
tcmCFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { tcmCFacilityHistorical15minEntry 7 }
endOfTcmCFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 30 }
tcmCFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcmCFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 31 }
tcmCFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX TcmCFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
tcmCFacilityHistorical1dayNumber
}
::= { tcmCFacilityHistorical1dayTable 1 }
TcmCFacilityHistorical1dayEntry ::= SEQUENCE
{ tcmCFacilityHistorical1dayNumber Integer32,
tcmCFacilityHistorical1dayES Unsigned32,
tcmCFacilityHistorical1daySES Unsigned32,
tcmCFacilityHistorical1dayBbe Counter64String,
tcmCFacilityHistorical1dayUAS Unsigned32,
tcmCFacilityHistorical1dayValidFlag TruthValue,
tcmCFacilityHistorical1dayTimeStamp DateAndTime }
tcmCFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { tcmCFacilityHistorical1dayEntry 1 }
tcmCFacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Errored Seconds"
::= { tcmCFacilityHistorical1dayEntry 2 }
tcmCFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Severely Errored Seconds"
::= { tcmCFacilityHistorical1dayEntry 3 }
tcmCFacilityHistorical1dayBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Background Block Errors"
::= { tcmCFacilityHistorical1dayEntry 4 }
tcmCFacilityHistorical1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU Tandem Connection Monitoring C Unavailable Seconds"
::= { tcmCFacilityHistorical1dayEntry 5 }
tcmCFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { tcmCFacilityHistorical1dayEntry 6 }
tcmCFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { tcmCFacilityHistorical1dayEntry 7 }
endOfTcmCFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 32 }
otuFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OtuFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 33 }
otuFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX OtuFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { otuFacilityCurrent15minTable 1 }
OtuFacilityCurrent15minEntry ::= SEQUENCE
{ otuFacilityCurrent15minES Unsigned32,
otuFacilityCurrent15minSES Unsigned32,
otuFacilityCurrent15minBbe Counter64String,
otuFacilityCurrent15minUAS Unsigned32,
otuFacilityCurrent15minElapsedTime Integer32 }
otuFacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Errored Seconds"
::= { otuFacilityCurrent15minEntry 1 }
otuFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Severely Errored Seconds"
::= { otuFacilityCurrent15minEntry 2 }
otuFacilityCurrent15minBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Background Block Errors"
::= { otuFacilityCurrent15minEntry 3 }
otuFacilityCurrent15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Unavailable Seconds"
::= { otuFacilityCurrent15minEntry 4 }
otuFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { otuFacilityCurrent15minEntry 5 }
endOfOtuFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 34 }
otuFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OtuFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 35 }
otuFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX OtuFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { otuFacilityCurrent1dayTable 1 }
OtuFacilityCurrent1dayEntry ::= SEQUENCE
{ otuFacilityCurrent1dayES Unsigned32,
otuFacilityCurrent1daySES Unsigned32,
otuFacilityCurrent1dayBbe Counter64String,
otuFacilityCurrent1dayUAS Unsigned32,
otuFacilityCurrent1dayElapsedTime Integer32 }
otuFacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Errored Seconds"
::= { otuFacilityCurrent1dayEntry 1 }
otuFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Severely Errored Seconds"
::= { otuFacilityCurrent1dayEntry 2 }
otuFacilityCurrent1dayBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Background Block Errors"
::= { otuFacilityCurrent1dayEntry 3 }
otuFacilityCurrent1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Unavailable Seconds"
::= { otuFacilityCurrent1dayEntry 4 }
otuFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { otuFacilityCurrent1dayEntry 5 }
endOfOtuFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 36 }
otuFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OtuFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 37 }
otuFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX OtuFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
otuFacilityHistorical15minNumber
}
::= { otuFacilityHistorical15minTable 1 }
OtuFacilityHistorical15minEntry ::= SEQUENCE
{ otuFacilityHistorical15minNumber Integer32,
otuFacilityHistorical15minES Unsigned32,
otuFacilityHistorical15minSES Unsigned32,
otuFacilityHistorical15minBbe Counter64String,
otuFacilityHistorical15minUAS Unsigned32,
otuFacilityHistorical15minValidFlag TruthValue,
otuFacilityHistorical15minTimeStamp DateAndTime }
otuFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { otuFacilityHistorical15minEntry 1 }
otuFacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Errored Seconds"
::= { otuFacilityHistorical15minEntry 2 }
otuFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Severely Errored Seconds"
::= { otuFacilityHistorical15minEntry 3 }
otuFacilityHistorical15minBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Background Block Errors"
::= { otuFacilityHistorical15minEntry 4 }
otuFacilityHistorical15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Unavailable Seconds"
::= { otuFacilityHistorical15minEntry 5 }
otuFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { otuFacilityHistorical15minEntry 6 }
otuFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { otuFacilityHistorical15minEntry 7 }
endOfOtuFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 38 }
otuFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OtuFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 39 }
otuFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX OtuFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
otuFacilityHistorical1dayNumber
}
::= { otuFacilityHistorical1dayTable 1 }
OtuFacilityHistorical1dayEntry ::= SEQUENCE
{ otuFacilityHistorical1dayNumber Integer32,
otuFacilityHistorical1dayES Unsigned32,
otuFacilityHistorical1daySES Unsigned32,
otuFacilityHistorical1dayBbe Counter64String,
otuFacilityHistorical1dayUAS Unsigned32,
otuFacilityHistorical1dayValidFlag TruthValue,
otuFacilityHistorical1dayTimeStamp DateAndTime }
otuFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { otuFacilityHistorical1dayEntry 1 }
otuFacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Errored Seconds"
::= { otuFacilityHistorical1dayEntry 2 }
otuFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Severely Errored Seconds"
::= { otuFacilityHistorical1dayEntry 3 }
otuFacilityHistorical1dayBbe OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Background Block Errors"
::= { otuFacilityHistorical1dayEntry 4 }
otuFacilityHistorical1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU Unavailable Seconds"
::= { otuFacilityHistorical1dayEntry 5 }
otuFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { otuFacilityHistorical1dayEntry 6 }
otuFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { otuFacilityHistorical1dayEntry 7 }
endOfOtuFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 40 }
otuFecFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OtuFecFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 41 }
otuFecFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX OtuFecFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { otuFecFacilityCurrent15minTable 1 }
OtuFecFacilityCurrent15minEntry ::= SEQUENCE
{ otuFecFacilityCurrent15minES Unsigned32,
otuFecFacilityCurrent15minSES Unsigned32,
otuFecFacilityCurrent15minCE Counter64String,
otuFecFacilityCurrent15minUBE Counter64String,
otuFecFacilityCurrent15minBERCE Counter64String,
otuFecFacilityCurrent15minElapsedTime Integer32 }
otuFecFacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Errored Seconds"
::= { otuFecFacilityCurrent15minEntry 1 }
otuFecFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Severely Errored Seconds"
::= { otuFecFacilityCurrent15minEntry 2 }
otuFecFacilityCurrent15minCE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Corrected Errors"
::= { otuFecFacilityCurrent15minEntry 3 }
otuFecFacilityCurrent15minUBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Uncorrected Block Errors"
::= { otuFecFacilityCurrent15minEntry 4 }
otuFecFacilityCurrent15minBERCE OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-18"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Error Rate before Foward Error Correction (FEC) calculated from corrected errors"
::= { otuFecFacilityCurrent15minEntry 5 }
otuFecFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { otuFecFacilityCurrent15minEntry 6 }
endOfOtuFecFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 42 }
otuFecFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OtuFecFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 43 }
otuFecFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX OtuFecFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { otuFecFacilityCurrent1dayTable 1 }
OtuFecFacilityCurrent1dayEntry ::= SEQUENCE
{ otuFecFacilityCurrent1dayES Unsigned32,
otuFecFacilityCurrent1daySES Unsigned32,
otuFecFacilityCurrent1dayCE Counter64String,
otuFecFacilityCurrent1dayUBE Counter64String,
otuFecFacilityCurrent1dayBERCE Counter64String,
otuFecFacilityCurrent1dayElapsedTime Integer32 }
otuFecFacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Errored Seconds"
::= { otuFecFacilityCurrent1dayEntry 1 }
otuFecFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Severely Errored Seconds"
::= { otuFecFacilityCurrent1dayEntry 2 }
otuFecFacilityCurrent1dayCE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Corrected Errors"
::= { otuFecFacilityCurrent1dayEntry 3 }
otuFecFacilityCurrent1dayUBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Uncorrected Block Errors"
::= { otuFecFacilityCurrent1dayEntry 4 }
otuFecFacilityCurrent1dayBERCE OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-18"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Error Rate before Foward Error Correction (FEC) calculated from corrected errors"
::= { otuFecFacilityCurrent1dayEntry 5 }
otuFecFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { otuFecFacilityCurrent1dayEntry 6 }
endOfOtuFecFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 44 }
otuFecFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OtuFecFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 45 }
otuFecFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX OtuFecFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
otuFecFacilityHistorical15minNumber
}
::= { otuFecFacilityHistorical15minTable 1 }
OtuFecFacilityHistorical15minEntry ::= SEQUENCE
{ otuFecFacilityHistorical15minNumber Integer32,
otuFecFacilityHistorical15minES Unsigned32,
otuFecFacilityHistorical15minSES Unsigned32,
otuFecFacilityHistorical15minCE Counter64String,
otuFecFacilityHistorical15minUBE Counter64String,
otuFecFacilityHistorical15minBERCE Counter64String,
otuFecFacilityHistorical15minValidFlag TruthValue,
otuFecFacilityHistorical15minTimeStamp DateAndTime }
otuFecFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { otuFecFacilityHistorical15minEntry 1 }
otuFecFacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Errored Seconds"
::= { otuFecFacilityHistorical15minEntry 2 }
otuFecFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Severely Errored Seconds"
::= { otuFecFacilityHistorical15minEntry 3 }
otuFecFacilityHistorical15minCE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Corrected Errors"
::= { otuFecFacilityHistorical15minEntry 4 }
otuFecFacilityHistorical15minUBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Uncorrected Block Errors"
::= { otuFecFacilityHistorical15minEntry 5 }
otuFecFacilityHistorical15minBERCE OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-18"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Error Rate before Foward Error Correction (FEC) calculated from corrected errors"
::= { otuFecFacilityHistorical15minEntry 6 }
otuFecFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { otuFecFacilityHistorical15minEntry 7 }
otuFecFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { otuFecFacilityHistorical15minEntry 8 }
endOfOtuFecFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 46 }
otuFecFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OtuFecFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 47 }
otuFecFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX OtuFecFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
otuFecFacilityHistorical1dayNumber
}
::= { otuFecFacilityHistorical1dayTable 1 }
OtuFecFacilityHistorical1dayEntry ::= SEQUENCE
{ otuFecFacilityHistorical1dayNumber Integer32,
otuFecFacilityHistorical1dayES Unsigned32,
otuFecFacilityHistorical1daySES Unsigned32,
otuFecFacilityHistorical1dayCE Counter64String,
otuFecFacilityHistorical1dayUBE Counter64String,
otuFecFacilityHistorical1dayBERCE Counter64String,
otuFecFacilityHistorical1dayValidFlag TruthValue,
otuFecFacilityHistorical1dayTimeStamp DateAndTime }
otuFecFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { otuFecFacilityHistorical1dayEntry 1 }
otuFecFacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Errored Seconds"
::= { otuFecFacilityHistorical1dayEntry 2 }
otuFecFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Severely Errored Seconds"
::= { otuFecFacilityHistorical1dayEntry 3 }
otuFecFacilityHistorical1dayCE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Corrected Errors"
::= { otuFecFacilityHistorical1dayEntry 4 }
otuFecFacilityHistorical1dayUBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Uncorrected Block Errors"
::= { otuFecFacilityHistorical1dayEntry 5 }
otuFecFacilityHistorical1dayBERCE OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-18"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Error Rate before Foward Error Correction (FEC) calculated from corrected errors"
::= { otuFecFacilityHistorical1dayEntry 6 }
otuFecFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { otuFecFacilityHistorical1dayEntry 7 }
otuFecFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { otuFecFacilityHistorical1dayEntry 8 }
endOfOtuFecFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 48 }
fecFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FecFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 49 }
fecFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX FecFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { fecFacilityCurrent15minTable 1 }
FecFacilityCurrent15minEntry ::= SEQUENCE
{ fecFacilityCurrent15minSES Unsigned32,
fecFacilityCurrent15minCE Counter64String,
fecFacilityCurrent15minUBE Counter64String,
fecFacilityCurrent15minBERCE Counter64String,
fecFacilityCurrent15minElapsedTime Integer32 }
fecFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Severely Errored Seconds FEC Monitoring for internal use"
::= { fecFacilityCurrent15minEntry 1 }
fecFacilityCurrent15minCE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Corrected Errors"
::= { fecFacilityCurrent15minEntry 2 }
fecFacilityCurrent15minUBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Uncorrected Block Errors"
::= { fecFacilityCurrent15minEntry 3 }
fecFacilityCurrent15minBERCE OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-18"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Error Rate before Foward Error Correction (FEC) calculated from corrected errors"
::= { fecFacilityCurrent15minEntry 4 }
fecFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { fecFacilityCurrent15minEntry 5 }
endOfFecFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 50 }
fecFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FecFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 51 }
fecFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX FecFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { fecFacilityCurrent1dayTable 1 }
FecFacilityCurrent1dayEntry ::= SEQUENCE
{ fecFacilityCurrent1daySES Unsigned32,
fecFacilityCurrent1dayCE Counter64String,
fecFacilityCurrent1dayUBE Counter64String,
fecFacilityCurrent1dayBERCE Counter64String,
fecFacilityCurrent1dayElapsedTime Integer32 }
fecFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Severely Errored Seconds FEC Monitoring for internal use"
::= { fecFacilityCurrent1dayEntry 1 }
fecFacilityCurrent1dayCE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Corrected Errors"
::= { fecFacilityCurrent1dayEntry 2 }
fecFacilityCurrent1dayUBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Uncorrected Block Errors"
::= { fecFacilityCurrent1dayEntry 3 }
fecFacilityCurrent1dayBERCE OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-18"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Error Rate before Foward Error Correction (FEC) calculated from corrected errors"
::= { fecFacilityCurrent1dayEntry 4 }
fecFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { fecFacilityCurrent1dayEntry 5 }
endOfFecFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 52 }
fecFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FecFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 53 }
fecFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX FecFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
fecFacilityHistorical15minNumber
}
::= { fecFacilityHistorical15minTable 1 }
FecFacilityHistorical15minEntry ::= SEQUENCE
{ fecFacilityHistorical15minNumber Integer32,
fecFacilityHistorical15minSES Unsigned32,
fecFacilityHistorical15minCE Counter64String,
fecFacilityHistorical15minUBE Counter64String,
fecFacilityHistorical15minBERCE Counter64String,
fecFacilityHistorical15minValidFlag TruthValue,
fecFacilityHistorical15minTimeStamp DateAndTime }
fecFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { fecFacilityHistorical15minEntry 1 }
fecFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Severely Errored Seconds FEC Monitoring for internal use"
::= { fecFacilityHistorical15minEntry 2 }
fecFacilityHistorical15minCE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Corrected Errors"
::= { fecFacilityHistorical15minEntry 3 }
fecFacilityHistorical15minUBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Uncorrected Block Errors"
::= { fecFacilityHistorical15minEntry 4 }
fecFacilityHistorical15minBERCE OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-18"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Error Rate before Foward Error Correction (FEC) calculated from corrected errors"
::= { fecFacilityHistorical15minEntry 5 }
fecFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { fecFacilityHistorical15minEntry 6 }
fecFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { fecFacilityHistorical15minEntry 7 }
endOfFecFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 54 }
fecFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FecFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 55 }
fecFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX FecFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
fecFacilityHistorical1dayNumber
}
::= { fecFacilityHistorical1dayTable 1 }
FecFacilityHistorical1dayEntry ::= SEQUENCE
{ fecFacilityHistorical1dayNumber Integer32,
fecFacilityHistorical1daySES Unsigned32,
fecFacilityHistorical1dayCE Counter64String,
fecFacilityHistorical1dayUBE Counter64String,
fecFacilityHistorical1dayBERCE Counter64String,
fecFacilityHistorical1dayValidFlag TruthValue,
fecFacilityHistorical1dayTimeStamp DateAndTime }
fecFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { fecFacilityHistorical1dayEntry 1 }
fecFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Severely Errored Seconds FEC Monitoring for internal use"
::= { fecFacilityHistorical1dayEntry 2 }
fecFacilityHistorical1dayCE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Corrected Errors"
::= { fecFacilityHistorical1dayEntry 3 }
fecFacilityHistorical1dayUBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU FEC Uncorrected Block Errors"
::= { fecFacilityHistorical1dayEntry 4 }
fecFacilityHistorical1dayBERCE OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-18"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Error Rate before Foward Error Correction (FEC) calculated from corrected errors"
::= { fecFacilityHistorical1dayEntry 5 }
fecFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { fecFacilityHistorical1dayEntry 6 }
fecFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { fecFacilityHistorical1dayEntry 7 }
endOfFecFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 56 }
pcs1FacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs1FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 57 }
pcs1FacilityCurrent15minEntry OBJECT-TYPE
SYNTAX Pcs1FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { pcs1FacilityCurrent15minTable 1 }
Pcs1FacilityCurrent15minEntry ::= SEQUENCE
{ pcs1FacilityCurrent15minES Unsigned32,
pcs1FacilityCurrent15minCV Counter64String,
pcs1FacilityCurrent15minSE Unsigned32,
pcs1FacilityCurrent15minElapsedTime Integer32 }
pcs1FacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs1FacilityCurrent15minEntry 1 }
pcs1FacilityCurrent15minCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs1FacilityCurrent15minEntry 2 }
pcs1FacilityCurrent15minSE OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sync Header Errors Physical Coding Layer"
::= { pcs1FacilityCurrent15minEntry 3 }
pcs1FacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { pcs1FacilityCurrent15minEntry 4 }
endOfPcs1FacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 58 }
pcs1FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs1FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 59 }
pcs1FacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX Pcs1FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { pcs1FacilityCurrent1dayTable 1 }
Pcs1FacilityCurrent1dayEntry ::= SEQUENCE
{ pcs1FacilityCurrent1dayES Unsigned32,
pcs1FacilityCurrent1dayCV Counter64String,
pcs1FacilityCurrent1daySE Unsigned32,
pcs1FacilityCurrent1dayElapsedTime Integer32 }
pcs1FacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs1FacilityCurrent1dayEntry 1 }
pcs1FacilityCurrent1dayCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs1FacilityCurrent1dayEntry 2 }
pcs1FacilityCurrent1daySE OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sync Header Errors Physical Coding Layer"
::= { pcs1FacilityCurrent1dayEntry 3 }
pcs1FacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { pcs1FacilityCurrent1dayEntry 4 }
endOfPcs1FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 60 }
pcs1FacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs1FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 61 }
pcs1FacilityHistorical15minEntry OBJECT-TYPE
SYNTAX Pcs1FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
pcs1FacilityHistorical15minNumber
}
::= { pcs1FacilityHistorical15minTable 1 }
Pcs1FacilityHistorical15minEntry ::= SEQUENCE
{ pcs1FacilityHistorical15minNumber Integer32,
pcs1FacilityHistorical15minES Unsigned32,
pcs1FacilityHistorical15minCV Counter64String,
pcs1FacilityHistorical15minSE Unsigned32,
pcs1FacilityHistorical15minValidFlag TruthValue,
pcs1FacilityHistorical15minTimeStamp DateAndTime }
pcs1FacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { pcs1FacilityHistorical15minEntry 1 }
pcs1FacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs1FacilityHistorical15minEntry 2 }
pcs1FacilityHistorical15minCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs1FacilityHistorical15minEntry 3 }
pcs1FacilityHistorical15minSE OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sync Header Errors Physical Coding Layer"
::= { pcs1FacilityHistorical15minEntry 4 }
pcs1FacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { pcs1FacilityHistorical15minEntry 5 }
pcs1FacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { pcs1FacilityHistorical15minEntry 6 }
endOfPcs1FacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 62 }
pcs1FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs1FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 63 }
pcs1FacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX Pcs1FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
pcs1FacilityHistorical1dayNumber
}
::= { pcs1FacilityHistorical1dayTable 1 }
Pcs1FacilityHistorical1dayEntry ::= SEQUENCE
{ pcs1FacilityHistorical1dayNumber Integer32,
pcs1FacilityHistorical1dayES Unsigned32,
pcs1FacilityHistorical1dayCV Counter64String,
pcs1FacilityHistorical1daySE Unsigned32,
pcs1FacilityHistorical1dayValidFlag TruthValue,
pcs1FacilityHistorical1dayTimeStamp DateAndTime }
pcs1FacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { pcs1FacilityHistorical1dayEntry 1 }
pcs1FacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs1FacilityHistorical1dayEntry 2 }
pcs1FacilityHistorical1dayCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs1FacilityHistorical1dayEntry 3 }
pcs1FacilityHistorical1daySE OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sync Header Errors Physical Coding Layer"
::= { pcs1FacilityHistorical1dayEntry 4 }
pcs1FacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { pcs1FacilityHistorical1dayEntry 5 }
pcs1FacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { pcs1FacilityHistorical1dayEntry 6 }
endOfPcs1FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 64 }
pcs2FacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs2FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 65 }
pcs2FacilityCurrent15minEntry OBJECT-TYPE
SYNTAX Pcs2FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { pcs2FacilityCurrent15minTable 1 }
Pcs2FacilityCurrent15minEntry ::= SEQUENCE
{ pcs2FacilityCurrent15minES Unsigned32,
pcs2FacilityCurrent15minDE Unsigned32,
pcs2FacilityCurrent15minCV Counter64String,
pcs2FacilityCurrent15minElapsedTime Integer32 }
pcs2FacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs2FacilityCurrent15minEntry 1 }
pcs2FacilityCurrent15minDE OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Disparity Errors"
::= { pcs2FacilityCurrent15minEntry 2 }
pcs2FacilityCurrent15minCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs2FacilityCurrent15minEntry 3 }
pcs2FacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { pcs2FacilityCurrent15minEntry 4 }
endOfPcs2FacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 66 }
pcs2FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs2FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 67 }
pcs2FacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX Pcs2FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { pcs2FacilityCurrent1dayTable 1 }
Pcs2FacilityCurrent1dayEntry ::= SEQUENCE
{ pcs2FacilityCurrent1dayES Unsigned32,
pcs2FacilityCurrent1dayDE Unsigned32,
pcs2FacilityCurrent1dayCV Counter64String,
pcs2FacilityCurrent1dayElapsedTime Integer32 }
pcs2FacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs2FacilityCurrent1dayEntry 1 }
pcs2FacilityCurrent1dayDE OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Disparity Errors"
::= { pcs2FacilityCurrent1dayEntry 2 }
pcs2FacilityCurrent1dayCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs2FacilityCurrent1dayEntry 3 }
pcs2FacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { pcs2FacilityCurrent1dayEntry 4 }
endOfPcs2FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 68 }
pcs2FacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs2FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 69 }
pcs2FacilityHistorical15minEntry OBJECT-TYPE
SYNTAX Pcs2FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
pcs2FacilityHistorical15minNumber
}
::= { pcs2FacilityHistorical15minTable 1 }
Pcs2FacilityHistorical15minEntry ::= SEQUENCE
{ pcs2FacilityHistorical15minNumber Integer32,
pcs2FacilityHistorical15minES Unsigned32,
pcs2FacilityHistorical15minDE Unsigned32,
pcs2FacilityHistorical15minCV Counter64String,
pcs2FacilityHistorical15minValidFlag TruthValue,
pcs2FacilityHistorical15minTimeStamp DateAndTime }
pcs2FacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { pcs2FacilityHistorical15minEntry 1 }
pcs2FacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs2FacilityHistorical15minEntry 2 }
pcs2FacilityHistorical15minDE OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Disparity Errors"
::= { pcs2FacilityHistorical15minEntry 3 }
pcs2FacilityHistorical15minCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs2FacilityHistorical15minEntry 4 }
pcs2FacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { pcs2FacilityHistorical15minEntry 5 }
pcs2FacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { pcs2FacilityHistorical15minEntry 6 }
endOfPcs2FacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 70 }
pcs2FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs2FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 71 }
pcs2FacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX Pcs2FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
pcs2FacilityHistorical1dayNumber
}
::= { pcs2FacilityHistorical1dayTable 1 }
Pcs2FacilityHistorical1dayEntry ::= SEQUENCE
{ pcs2FacilityHistorical1dayNumber Integer32,
pcs2FacilityHistorical1dayES Unsigned32,
pcs2FacilityHistorical1dayDE Unsigned32,
pcs2FacilityHistorical1dayCV Counter64String,
pcs2FacilityHistorical1dayValidFlag TruthValue,
pcs2FacilityHistorical1dayTimeStamp DateAndTime }
pcs2FacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { pcs2FacilityHistorical1dayEntry 1 }
pcs2FacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs2FacilityHistorical1dayEntry 2 }
pcs2FacilityHistorical1dayDE OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Disparity Errors"
::= { pcs2FacilityHistorical1dayEntry 3 }
pcs2FacilityHistorical1dayCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs2FacilityHistorical1dayEntry 4 }
pcs2FacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { pcs2FacilityHistorical1dayEntry 5 }
pcs2FacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { pcs2FacilityHistorical1dayEntry 6 }
endOfPcs2FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 72 }
pcs3FacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs3FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 73 }
pcs3FacilityCurrent15minEntry OBJECT-TYPE
SYNTAX Pcs3FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { pcs3FacilityCurrent15minTable 1 }
Pcs3FacilityCurrent15minEntry ::= SEQUENCE
{ pcs3FacilityCurrent15minES Unsigned32,
pcs3FacilityCurrent15minCVDE Counter64String,
pcs3FacilityCurrent15minElapsedTime Integer32 }
pcs3FacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs3FacilityCurrent15minEntry 1 }
pcs3FacilityCurrent15minCVDE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations + Disparity Errors"
::= { pcs3FacilityCurrent15minEntry 2 }
pcs3FacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { pcs3FacilityCurrent15minEntry 3 }
endOfPcs3FacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 74 }
pcs3FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs3FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 75 }
pcs3FacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX Pcs3FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { pcs3FacilityCurrent1dayTable 1 }
Pcs3FacilityCurrent1dayEntry ::= SEQUENCE
{ pcs3FacilityCurrent1dayES Unsigned32,
pcs3FacilityCurrent1dayCVDE Counter64String,
pcs3FacilityCurrent1dayElapsedTime Integer32 }
pcs3FacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs3FacilityCurrent1dayEntry 1 }
pcs3FacilityCurrent1dayCVDE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations + Disparity Errors"
::= { pcs3FacilityCurrent1dayEntry 2 }
pcs3FacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { pcs3FacilityCurrent1dayEntry 3 }
endOfPcs3FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 76 }
pcs3FacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs3FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 77 }
pcs3FacilityHistorical15minEntry OBJECT-TYPE
SYNTAX Pcs3FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
pcs3FacilityHistorical15minNumber
}
::= { pcs3FacilityHistorical15minTable 1 }
Pcs3FacilityHistorical15minEntry ::= SEQUENCE
{ pcs3FacilityHistorical15minNumber Integer32,
pcs3FacilityHistorical15minES Unsigned32,
pcs3FacilityHistorical15minCVDE Counter64String,
pcs3FacilityHistorical15minValidFlag TruthValue,
pcs3FacilityHistorical15minTimeStamp DateAndTime }
pcs3FacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { pcs3FacilityHistorical15minEntry 1 }
pcs3FacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs3FacilityHistorical15minEntry 2 }
pcs3FacilityHistorical15minCVDE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations + Disparity Errors"
::= { pcs3FacilityHistorical15minEntry 3 }
pcs3FacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { pcs3FacilityHistorical15minEntry 4 }
pcs3FacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { pcs3FacilityHistorical15minEntry 5 }
endOfPcs3FacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 78 }
pcs3FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs3FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 79 }
pcs3FacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX Pcs3FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
pcs3FacilityHistorical1dayNumber
}
::= { pcs3FacilityHistorical1dayTable 1 }
Pcs3FacilityHistorical1dayEntry ::= SEQUENCE
{ pcs3FacilityHistorical1dayNumber Integer32,
pcs3FacilityHistorical1dayES Unsigned32,
pcs3FacilityHistorical1dayCVDE Counter64String,
pcs3FacilityHistorical1dayValidFlag TruthValue,
pcs3FacilityHistorical1dayTimeStamp DateAndTime }
pcs3FacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { pcs3FacilityHistorical1dayEntry 1 }
pcs3FacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs3FacilityHistorical1dayEntry 2 }
pcs3FacilityHistorical1dayCVDE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations + Disparity Errors"
::= { pcs3FacilityHistorical1dayEntry 3 }
pcs3FacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { pcs3FacilityHistorical1dayEntry 4 }
pcs3FacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { pcs3FacilityHistorical1dayEntry 5 }
endOfPcs3FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 80 }
pcs4FacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs4FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 81 }
pcs4FacilityCurrent15minEntry OBJECT-TYPE
SYNTAX Pcs4FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { pcs4FacilityCurrent15minTable 1 }
Pcs4FacilityCurrent15minEntry ::= SEQUENCE
{ pcs4FacilityCurrent15minES Unsigned32,
pcs4FacilityCurrent15minCV Counter64String,
pcs4FacilityCurrent15minBBE Counter64String,
pcs4FacilityCurrent15minElapsedTime Integer32 }
pcs4FacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs4FacilityCurrent15minEntry 1 }
pcs4FacilityCurrent15minCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs4FacilityCurrent15minEntry 2 }
pcs4FacilityCurrent15minBBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCS Background Block Errors"
::= { pcs4FacilityCurrent15minEntry 3 }
pcs4FacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { pcs4FacilityCurrent15minEntry 4 }
endOfPcs4FacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 82 }
pcs4FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs4FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 83 }
pcs4FacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX Pcs4FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { pcs4FacilityCurrent1dayTable 1 }
Pcs4FacilityCurrent1dayEntry ::= SEQUENCE
{ pcs4FacilityCurrent1dayES Unsigned32,
pcs4FacilityCurrent1dayCV Counter64String,
pcs4FacilityCurrent1dayBBE Counter64String,
pcs4FacilityCurrent1dayElapsedTime Integer32 }
pcs4FacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs4FacilityCurrent1dayEntry 1 }
pcs4FacilityCurrent1dayCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs4FacilityCurrent1dayEntry 2 }
pcs4FacilityCurrent1dayBBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCS Background Block Errors"
::= { pcs4FacilityCurrent1dayEntry 3 }
pcs4FacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { pcs4FacilityCurrent1dayEntry 4 }
endOfPcs4FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 84 }
pcs4FacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs4FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 85 }
pcs4FacilityHistorical15minEntry OBJECT-TYPE
SYNTAX Pcs4FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
pcs4FacilityHistorical15minNumber
}
::= { pcs4FacilityHistorical15minTable 1 }
Pcs4FacilityHistorical15minEntry ::= SEQUENCE
{ pcs4FacilityHistorical15minNumber Integer32,
pcs4FacilityHistorical15minES Unsigned32,
pcs4FacilityHistorical15minCV Counter64String,
pcs4FacilityHistorical15minBBE Counter64String,
pcs4FacilityHistorical15minValidFlag TruthValue,
pcs4FacilityHistorical15minTimeStamp DateAndTime }
pcs4FacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { pcs4FacilityHistorical15minEntry 1 }
pcs4FacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs4FacilityHistorical15minEntry 2 }
pcs4FacilityHistorical15minCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs4FacilityHistorical15minEntry 3 }
pcs4FacilityHistorical15minBBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCS Background Block Errors"
::= { pcs4FacilityHistorical15minEntry 4 }
pcs4FacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { pcs4FacilityHistorical15minEntry 5 }
pcs4FacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { pcs4FacilityHistorical15minEntry 6 }
endOfPcs4FacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 86 }
pcs4FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pcs4FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 87 }
pcs4FacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX Pcs4FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
pcs4FacilityHistorical1dayNumber
}
::= { pcs4FacilityHistorical1dayTable 1 }
Pcs4FacilityHistorical1dayEntry ::= SEQUENCE
{ pcs4FacilityHistorical1dayNumber Integer32,
pcs4FacilityHistorical1dayES Unsigned32,
pcs4FacilityHistorical1dayCV Counter64String,
pcs4FacilityHistorical1dayBBE Counter64String,
pcs4FacilityHistorical1dayValidFlag TruthValue,
pcs4FacilityHistorical1dayTimeStamp DateAndTime }
pcs4FacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { pcs4FacilityHistorical1dayEntry 1 }
pcs4FacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Errored Seconds"
::= { pcs4FacilityHistorical1dayEntry 2 }
pcs4FacilityHistorical1dayCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical Coding Layer Coding Violations"
::= { pcs4FacilityHistorical1dayEntry 3 }
pcs4FacilityHistorical1dayBBE OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCS Background Block Errors"
::= { pcs4FacilityHistorical1dayEntry 4 }
pcs4FacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { pcs4FacilityHistorical1dayEntry 5 }
pcs4FacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { pcs4FacilityHistorical1dayEntry 6 }
endOfPcs4FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 88 }
lFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF LFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 89 }
lFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX LFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { lFacilityCurrent15minTable 1 }
LFacilityCurrent15minEntry ::= SEQUENCE
{ lFacilityCurrent15minES Unsigned32,
lFacilityCurrent15minSES Unsigned32,
lFacilityCurrent15minUAS Unsigned32,
lFacilityCurrent15minCV Counter64String,
lFacilityCurrent15minElapsedTime Integer32 }
lFacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Errored Second"
::= { lFacilityCurrent15minEntry 1 }
lFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Severely Errored Seconds"
::= { lFacilityCurrent15minEntry 2 }
lFacilityCurrent15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Unavailable Seconds"
::= { lFacilityCurrent15minEntry 3 }
lFacilityCurrent15minCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Coding Violations"
::= { lFacilityCurrent15minEntry 4 }
lFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { lFacilityCurrent15minEntry 5 }
endOfLFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 90 }
lFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF LFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 91 }
lFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX LFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { lFacilityCurrent1dayTable 1 }
LFacilityCurrent1dayEntry ::= SEQUENCE
{ lFacilityCurrent1dayES Unsigned32,
lFacilityCurrent1daySES Unsigned32,
lFacilityCurrent1dayUAS Unsigned32,
lFacilityCurrent1dayCV Counter64String,
lFacilityCurrent1dayElapsedTime Integer32 }
lFacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Errored Second"
::= { lFacilityCurrent1dayEntry 1 }
lFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Severely Errored Seconds"
::= { lFacilityCurrent1dayEntry 2 }
lFacilityCurrent1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Unavailable Seconds"
::= { lFacilityCurrent1dayEntry 3 }
lFacilityCurrent1dayCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Coding Violations"
::= { lFacilityCurrent1dayEntry 4 }
lFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { lFacilityCurrent1dayEntry 5 }
endOfLFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 92 }
lFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF LFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 93 }
lFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX LFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
lFacilityHistorical15minNumber
}
::= { lFacilityHistorical15minTable 1 }
LFacilityHistorical15minEntry ::= SEQUENCE
{ lFacilityHistorical15minNumber Integer32,
lFacilityHistorical15minES Unsigned32,
lFacilityHistorical15minSES Unsigned32,
lFacilityHistorical15minUAS Unsigned32,
lFacilityHistorical15minCV Counter64String,
lFacilityHistorical15minValidFlag TruthValue,
lFacilityHistorical15minTimeStamp DateAndTime }
lFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { lFacilityHistorical15minEntry 1 }
lFacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Errored Second"
::= { lFacilityHistorical15minEntry 2 }
lFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Severely Errored Seconds"
::= { lFacilityHistorical15minEntry 3 }
lFacilityHistorical15minUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Unavailable Seconds"
::= { lFacilityHistorical15minEntry 4 }
lFacilityHistorical15minCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Coding Violations"
::= { lFacilityHistorical15minEntry 5 }
lFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { lFacilityHistorical15minEntry 6 }
lFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { lFacilityHistorical15minEntry 7 }
endOfLFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 94 }
lFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF LFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 95 }
lFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX LFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
lFacilityHistorical1dayNumber
}
::= { lFacilityHistorical1dayTable 1 }
LFacilityHistorical1dayEntry ::= SEQUENCE
{ lFacilityHistorical1dayNumber Integer32,
lFacilityHistorical1dayES Unsigned32,
lFacilityHistorical1daySES Unsigned32,
lFacilityHistorical1dayUAS Unsigned32,
lFacilityHistorical1dayCV Counter64String,
lFacilityHistorical1dayValidFlag TruthValue,
lFacilityHistorical1dayTimeStamp DateAndTime }
lFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { lFacilityHistorical1dayEntry 1 }
lFacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Errored Second"
::= { lFacilityHistorical1dayEntry 2 }
lFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Severely Errored Seconds"
::= { lFacilityHistorical1dayEntry 3 }
lFacilityHistorical1dayUAS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Unavailable Seconds"
::= { lFacilityHistorical1dayEntry 4 }
lFacilityHistorical1dayCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line / Multiplex Section Coding Violations"
::= { lFacilityHistorical1dayEntry 5 }
lFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { lFacilityHistorical1dayEntry 6 }
lFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { lFacilityHistorical1dayEntry 7 }
endOfLFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 96 }
sFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF SFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 97 }
sFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX SFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { sFacilityCurrent15minTable 1 }
SFacilityCurrent15minEntry ::= SEQUENCE
{ sFacilityCurrent15minES Unsigned32,
sFacilityCurrent15minSES Unsigned32,
sFacilityCurrent15minSEFS Unsigned32,
sFacilityCurrent15minCV Counter64String,
sFacilityCurrent15minElapsedTime Integer32 }
sFacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section / Regenerator Section Errored Seconds"
::= { sFacilityCurrent15minEntry 1 }
sFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section Severely Errored Seconds"
::= { sFacilityCurrent15minEntry 2 }
sFacilityCurrent15minSEFS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section Severely Errored Frame Seconds"
::= { sFacilityCurrent15minEntry 3 }
sFacilityCurrent15minCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section / Regenator Section Coding Violations"
::= { sFacilityCurrent15minEntry 4 }
sFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { sFacilityCurrent15minEntry 5 }
endOfSFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 98 }
sFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF SFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 99 }
sFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX SFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { sFacilityCurrent1dayTable 1 }
SFacilityCurrent1dayEntry ::= SEQUENCE
{ sFacilityCurrent1dayES Unsigned32,
sFacilityCurrent1daySES Unsigned32,
sFacilityCurrent1daySEFS Unsigned32,
sFacilityCurrent1dayCV Counter64String,
sFacilityCurrent1dayElapsedTime Integer32 }
sFacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section / Regenerator Section Errored Seconds"
::= { sFacilityCurrent1dayEntry 1 }
sFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section Severely Errored Seconds"
::= { sFacilityCurrent1dayEntry 2 }
sFacilityCurrent1daySEFS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section Severely Errored Frame Seconds"
::= { sFacilityCurrent1dayEntry 3 }
sFacilityCurrent1dayCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section / Regenator Section Coding Violations"
::= { sFacilityCurrent1dayEntry 4 }
sFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { sFacilityCurrent1dayEntry 5 }
endOfSFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 100 }
sFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF SFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 101 }
sFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX SFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
sFacilityHistorical15minNumber
}
::= { sFacilityHistorical15minTable 1 }
SFacilityHistorical15minEntry ::= SEQUENCE
{ sFacilityHistorical15minNumber Integer32,
sFacilityHistorical15minES Unsigned32,
sFacilityHistorical15minSES Unsigned32,
sFacilityHistorical15minSEFS Unsigned32,
sFacilityHistorical15minCV Counter64String,
sFacilityHistorical15minValidFlag TruthValue,
sFacilityHistorical15minTimeStamp DateAndTime }
sFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { sFacilityHistorical15minEntry 1 }
sFacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section / Regenerator Section Errored Seconds"
::= { sFacilityHistorical15minEntry 2 }
sFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section Severely Errored Seconds"
::= { sFacilityHistorical15minEntry 3 }
sFacilityHistorical15minSEFS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section Severely Errored Frame Seconds"
::= { sFacilityHistorical15minEntry 4 }
sFacilityHistorical15minCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section / Regenator Section Coding Violations"
::= { sFacilityHistorical15minEntry 5 }
sFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { sFacilityHistorical15minEntry 6 }
sFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { sFacilityHistorical15minEntry 7 }
endOfSFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 102 }
sFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF SFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 103 }
sFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX SFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
sFacilityHistorical1dayNumber
}
::= { sFacilityHistorical1dayTable 1 }
SFacilityHistorical1dayEntry ::= SEQUENCE
{ sFacilityHistorical1dayNumber Integer32,
sFacilityHistorical1dayES Unsigned32,
sFacilityHistorical1daySES Unsigned32,
sFacilityHistorical1daySEFS Unsigned32,
sFacilityHistorical1dayCV Counter64String,
sFacilityHistorical1dayValidFlag TruthValue,
sFacilityHistorical1dayTimeStamp DateAndTime }
sFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { sFacilityHistorical1dayEntry 1 }
sFacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section / Regenerator Section Errored Seconds"
::= { sFacilityHistorical1dayEntry 2 }
sFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section Severely Errored Seconds"
::= { sFacilityHistorical1dayEntry 3 }
sFacilityHistorical1daySEFS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section Severely Errored Frame Seconds"
::= { sFacilityHistorical1dayEntry 4 }
sFacilityHistorical1dayCV OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section / Regenator Section Coding Violations"
::= { sFacilityHistorical1dayEntry 5 }
sFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { sFacilityHistorical1dayEntry 6 }
sFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { sFacilityHistorical1dayEntry 7 }
endOfSFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 104 }
gfpfrFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF GfpfrFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 105 }
gfpfrFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX GfpfrFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { gfpfrFacilityCurrent15minTable 1 }
GfpfrFacilityCurrent15minEntry ::= SEQUENCE
{ gfpfrFacilityCurrent15minGoodFrames Counter64String,
gfpfrFacilityCurrent15minCHecDiscardedFrames Counter64String,
gfpfrFacilityCurrent15minTHecDiscardedFrames Counter64String,
gfpfrFacilityCurrent15minElapsedTime Integer32 }
gfpfrFacilityCurrent15minGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"GFP Valid Frames"
::= { gfpfrFacilityCurrent15minEntry 1 }
gfpfrFacilityCurrent15minCHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Core HEC Discarded Frames"
::= { gfpfrFacilityCurrent15minEntry 2 }
gfpfrFacilityCurrent15minTHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Discarded Frames"
::= { gfpfrFacilityCurrent15minEntry 3 }
gfpfrFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { gfpfrFacilityCurrent15minEntry 4 }
endOfGfpfrFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 106 }
gfpfrFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF GfpfrFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 107 }
gfpfrFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX GfpfrFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { gfpfrFacilityCurrent1dayTable 1 }
GfpfrFacilityCurrent1dayEntry ::= SEQUENCE
{ gfpfrFacilityCurrent1dayGoodFrames Counter64String,
gfpfrFacilityCurrent1dayCHecDiscardedFrames Counter64String,
gfpfrFacilityCurrent1dayTHecDiscardedFrames Counter64String,
gfpfrFacilityCurrent1dayElapsedTime Integer32 }
gfpfrFacilityCurrent1dayGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"GFP Valid Frames"
::= { gfpfrFacilityCurrent1dayEntry 1 }
gfpfrFacilityCurrent1dayCHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Core HEC Discarded Frames"
::= { gfpfrFacilityCurrent1dayEntry 2 }
gfpfrFacilityCurrent1dayTHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Discarded Frames"
::= { gfpfrFacilityCurrent1dayEntry 3 }
gfpfrFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { gfpfrFacilityCurrent1dayEntry 4 }
endOfGfpfrFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 108 }
gfpfrFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF GfpfrFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 109 }
gfpfrFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX GfpfrFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
gfpfrFacilityHistorical15minNumber
}
::= { gfpfrFacilityHistorical15minTable 1 }
GfpfrFacilityHistorical15minEntry ::= SEQUENCE
{ gfpfrFacilityHistorical15minNumber Integer32,
gfpfrFacilityHistorical15minGoodFrames Counter64String,
gfpfrFacilityHistorical15minCHecDiscardedFrames Counter64String,
gfpfrFacilityHistorical15minTHecDiscardedFrames Counter64String,
gfpfrFacilityHistorical15minValidFlag TruthValue,
gfpfrFacilityHistorical15minTimeStamp DateAndTime }
gfpfrFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { gfpfrFacilityHistorical15minEntry 1 }
gfpfrFacilityHistorical15minGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"GFP Valid Frames"
::= { gfpfrFacilityHistorical15minEntry 2 }
gfpfrFacilityHistorical15minCHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Core HEC Discarded Frames"
::= { gfpfrFacilityHistorical15minEntry 3 }
gfpfrFacilityHistorical15minTHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Discarded Frames"
::= { gfpfrFacilityHistorical15minEntry 4 }
gfpfrFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { gfpfrFacilityHistorical15minEntry 5 }
gfpfrFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { gfpfrFacilityHistorical15minEntry 6 }
endOfGfpfrFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 110 }
gfpfrFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF GfpfrFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 111 }
gfpfrFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX GfpfrFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
gfpfrFacilityHistorical1dayNumber
}
::= { gfpfrFacilityHistorical1dayTable 1 }
GfpfrFacilityHistorical1dayEntry ::= SEQUENCE
{ gfpfrFacilityHistorical1dayNumber Integer32,
gfpfrFacilityHistorical1dayGoodFrames Counter64String,
gfpfrFacilityHistorical1dayCHecDiscardedFrames Counter64String,
gfpfrFacilityHistorical1dayTHecDiscardedFrames Counter64String,
gfpfrFacilityHistorical1dayValidFlag TruthValue,
gfpfrFacilityHistorical1dayTimeStamp DateAndTime }
gfpfrFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { gfpfrFacilityHistorical1dayEntry 1 }
gfpfrFacilityHistorical1dayGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"GFP Valid Frames"
::= { gfpfrFacilityHistorical1dayEntry 2 }
gfpfrFacilityHistorical1dayCHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Core HEC Discarded Frames"
::= { gfpfrFacilityHistorical1dayEntry 3 }
gfpfrFacilityHistorical1dayTHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Discarded Frames"
::= { gfpfrFacilityHistorical1dayEntry 4 }
gfpfrFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { gfpfrFacilityHistorical1dayEntry 5 }
gfpfrFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { gfpfrFacilityHistorical1dayEntry 6 }
endOfGfpfrFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 112 }
checfrFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChecfrFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 113 }
checfrFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX ChecfrFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { checfrFacilityCurrent15minTable 1 }
ChecfrFacilityCurrent15minEntry ::= SEQUENCE
{ checfrFacilityCurrent15minCoreHecCorrectedFrames Unsigned32,
checfrFacilityCurrent15minTypeHecCorrectedFrames Unsigned32,
checfrFacilityCurrent15minTypeHecDiscardedFrames Counter64String,
checfrFacilityCurrent15minElapsedTime Integer32 }
checfrFacilityCurrent15minCoreHecCorrectedFrames OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Core HEC Corrected Frames"
::= { checfrFacilityCurrent15minEntry 1 }
checfrFacilityCurrent15minTypeHecCorrectedFrames OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Corrected Frames"
::= { checfrFacilityCurrent15minEntry 2 }
checfrFacilityCurrent15minTypeHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Discarded Frames"
::= { checfrFacilityCurrent15minEntry 3 }
checfrFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { checfrFacilityCurrent15minEntry 4 }
endOfChecfrFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 114 }
checfrFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChecfrFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 115 }
checfrFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX ChecfrFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { checfrFacilityCurrent1dayTable 1 }
ChecfrFacilityCurrent1dayEntry ::= SEQUENCE
{ checfrFacilityCurrent1dayCoreHecCorrectedFrames Unsigned32,
checfrFacilityCurrent1dayTypeHecCorrectedFrames Unsigned32,
checfrFacilityCurrent1dayTypeHecDiscardedFrames Counter64String,
checfrFacilityCurrent1dayElapsedTime Integer32 }
checfrFacilityCurrent1dayCoreHecCorrectedFrames OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Core HEC Corrected Frames"
::= { checfrFacilityCurrent1dayEntry 1 }
checfrFacilityCurrent1dayTypeHecCorrectedFrames OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Corrected Frames"
::= { checfrFacilityCurrent1dayEntry 2 }
checfrFacilityCurrent1dayTypeHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Discarded Frames"
::= { checfrFacilityCurrent1dayEntry 3 }
checfrFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { checfrFacilityCurrent1dayEntry 4 }
endOfChecfrFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 116 }
checfrFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChecfrFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 117 }
checfrFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX ChecfrFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
checfrFacilityHistorical15minNumber
}
::= { checfrFacilityHistorical15minTable 1 }
ChecfrFacilityHistorical15minEntry ::= SEQUENCE
{ checfrFacilityHistorical15minNumber Integer32,
checfrFacilityHistorical15minCoreHecCorrectedFrames Unsigned32,
checfrFacilityHistorical15minTypeHecCorrectedFrames Unsigned32,
checfrFacilityHistorical15minTypeHecDiscardedFrames Counter64String,
checfrFacilityHistorical15minValidFlag TruthValue,
checfrFacilityHistorical15minTimeStamp DateAndTime }
checfrFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { checfrFacilityHistorical15minEntry 1 }
checfrFacilityHistorical15minCoreHecCorrectedFrames OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Core HEC Corrected Frames"
::= { checfrFacilityHistorical15minEntry 2 }
checfrFacilityHistorical15minTypeHecCorrectedFrames OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Corrected Frames"
::= { checfrFacilityHistorical15minEntry 3 }
checfrFacilityHistorical15minTypeHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Discarded Frames"
::= { checfrFacilityHistorical15minEntry 4 }
checfrFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { checfrFacilityHistorical15minEntry 5 }
checfrFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { checfrFacilityHistorical15minEntry 6 }
endOfChecfrFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 118 }
checfrFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChecfrFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 119 }
checfrFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX ChecfrFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
checfrFacilityHistorical1dayNumber
}
::= { checfrFacilityHistorical1dayTable 1 }
ChecfrFacilityHistorical1dayEntry ::= SEQUENCE
{ checfrFacilityHistorical1dayNumber Integer32,
checfrFacilityHistorical1dayCoreHecCorrectedFrames Unsigned32,
checfrFacilityHistorical1dayTypeHecCorrectedFrames Unsigned32,
checfrFacilityHistorical1dayTypeHecDiscardedFrames Counter64String,
checfrFacilityHistorical1dayValidFlag TruthValue,
checfrFacilityHistorical1dayTimeStamp DateAndTime }
checfrFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { checfrFacilityHistorical1dayEntry 1 }
checfrFacilityHistorical1dayCoreHecCorrectedFrames OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Core HEC Corrected Frames"
::= { checfrFacilityHistorical1dayEntry 2 }
checfrFacilityHistorical1dayTypeHecCorrectedFrames OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Corrected Frames"
::= { checfrFacilityHistorical1dayEntry 3 }
checfrFacilityHistorical1dayTypeHecDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type Field HEC Discarded Frames"
::= { checfrFacilityHistorical1dayEntry 4 }
checfrFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { checfrFacilityHistorical1dayEntry 5 }
checfrFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { checfrFacilityHistorical1dayEntry 6 }
endOfChecfrFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 120 }
discsBlockFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiscsBlockFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 121 }
discsBlockFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX DiscsBlockFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { discsBlockFacilityCurrent15minTable 1 }
DiscsBlockFacilityCurrent15minEntry ::= SEQUENCE
{ discsBlockFacilityCurrent15minDiscardedSuperblocks Unsigned32,
discsBlockFacilityCurrent15minElapsedTime Integer32 }
discsBlockFacilityCurrent15minDiscardedSuperblocks OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Discarded Super Blocks"
::= { discsBlockFacilityCurrent15minEntry 1 }
discsBlockFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { discsBlockFacilityCurrent15minEntry 2 }
endOfDiscsBlockFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 122 }
discsBlockFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiscsBlockFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 123 }
discsBlockFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX DiscsBlockFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { discsBlockFacilityCurrent1dayTable 1 }
DiscsBlockFacilityCurrent1dayEntry ::= SEQUENCE
{ discsBlockFacilityCurrent1dayDiscardedSuperblocks Unsigned32,
discsBlockFacilityCurrent1dayElapsedTime Integer32 }
discsBlockFacilityCurrent1dayDiscardedSuperblocks OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Discarded Super Blocks"
::= { discsBlockFacilityCurrent1dayEntry 1 }
discsBlockFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { discsBlockFacilityCurrent1dayEntry 2 }
endOfDiscsBlockFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 124 }
discsBlockFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiscsBlockFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 125 }
discsBlockFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX DiscsBlockFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
discsBlockFacilityHistorical15minNumber
}
::= { discsBlockFacilityHistorical15minTable 1 }
DiscsBlockFacilityHistorical15minEntry ::= SEQUENCE
{ discsBlockFacilityHistorical15minNumber Integer32,
discsBlockFacilityHistorical15minDiscardedSuperblocks Unsigned32,
discsBlockFacilityHistorical15minValidFlag TruthValue,
discsBlockFacilityHistorical15minTimeStamp DateAndTime }
discsBlockFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { discsBlockFacilityHistorical15minEntry 1 }
discsBlockFacilityHistorical15minDiscardedSuperblocks OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Discarded Super Blocks"
::= { discsBlockFacilityHistorical15minEntry 2 }
discsBlockFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { discsBlockFacilityHistorical15minEntry 3 }
discsBlockFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { discsBlockFacilityHistorical15minEntry 4 }
endOfDiscsBlockFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 126 }
discsBlockFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiscsBlockFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 127 }
discsBlockFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX DiscsBlockFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
discsBlockFacilityHistorical1dayNumber
}
::= { discsBlockFacilityHistorical1dayTable 1 }
DiscsBlockFacilityHistorical1dayEntry ::= SEQUENCE
{ discsBlockFacilityHistorical1dayNumber Integer32,
discsBlockFacilityHistorical1dayDiscardedSuperblocks Unsigned32,
discsBlockFacilityHistorical1dayValidFlag TruthValue,
discsBlockFacilityHistorical1dayTimeStamp DateAndTime }
discsBlockFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { discsBlockFacilityHistorical1dayEntry 1 }
discsBlockFacilityHistorical1dayDiscardedSuperblocks OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Discarded Super Blocks"
::= { discsBlockFacilityHistorical1dayEntry 2 }
discsBlockFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { discsBlockFacilityHistorical1dayEntry 3 }
discsBlockFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { discsBlockFacilityHistorical1dayEntry 4 }
endOfDiscsBlockFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 128 }
l2PortTxFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2PortTxFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 129 }
l2PortTxFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX L2PortTxFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { l2PortTxFacilityCurrent15minTable 1 }
L2PortTxFacilityCurrent15minEntry ::= SEQUENCE
{ l2PortTxFacilityCurrent15minFramesTrmt Counter64String,
l2PortTxFacilityCurrent15minBytesTrmt Counter64String,
l2PortTxFacilityCurrent15minBroadcastFramesTrmt Counter64String,
l2PortTxFacilityCurrent15minMulticastFramesTrmt Counter64String,
l2PortTxFacilityCurrent15minPauseFramesTrmt Counter64String,
l2PortTxFacilityCurrent15minBytesFrames64Trmt Counter64String,
l2PortTxFacilityCurrent15minBytesFrames65Trmt Counter64String,
l2PortTxFacilityCurrent15minBytesFrames128Trmt Counter64String,
l2PortTxFacilityCurrent15minBytesFrames256Trmt Counter64String,
l2PortTxFacilityCurrent15minBytesFrames512Trmt Counter64String,
l2PortTxFacilityCurrent15minBytesFrames1024Trmt Counter64String,
l2PortTxFacilityCurrent15minBytesFrames1519Trmt Counter64String,
l2PortTxFacilityCurrent15minElapsedTime Integer32 }
l2PortTxFacilityCurrent15minFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { l2PortTxFacilityCurrent15minEntry 1 }
l2PortTxFacilityCurrent15minBytesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { l2PortTxFacilityCurrent15minEntry 2 }
l2PortTxFacilityCurrent15minBroadcastFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Transmitted"
::= { l2PortTxFacilityCurrent15minEntry 3 }
l2PortTxFacilityCurrent15minMulticastFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { l2PortTxFacilityCurrent15minEntry 4 }
l2PortTxFacilityCurrent15minPauseFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { l2PortTxFacilityCurrent15minEntry 5 }
l2PortTxFacilityCurrent15minBytesFrames64Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent15minEntry 6 }
l2PortTxFacilityCurrent15minBytesFrames65Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent15minEntry 7 }
l2PortTxFacilityCurrent15minBytesFrames128Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent15minEntry 8 }
l2PortTxFacilityCurrent15minBytesFrames256Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent15minEntry 9 }
l2PortTxFacilityCurrent15minBytesFrames512Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent15minEntry 10 }
l2PortTxFacilityCurrent15minBytesFrames1024Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent15minEntry 11 }
l2PortTxFacilityCurrent15minBytesFrames1519Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent15minEntry 12 }
l2PortTxFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { l2PortTxFacilityCurrent15minEntry 13 }
endOfL2ProtTxFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 130 }
l2PortTxFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2PortTxFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 131 }
l2PortTxFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX L2PortTxFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { l2PortTxFacilityCurrent1dayTable 1 }
L2PortTxFacilityCurrent1dayEntry ::= SEQUENCE
{ l2PortTxFacilityCurrent1dayFramesTrmt Counter64String,
l2PortTxFacilityCurrent1dayBytesTrmt Counter64String,
l2PortTxFacilityCurrent1dayBroadcastFramesTrmt Counter64String,
l2PortTxFacilityCurrent1dayMulticastFramesTrmt Counter64String,
l2PortTxFacilityCurrent1dayPauseFramesTrmt Counter64String,
l2PortTxFacilityCurrent1dayBytesFrames64Trmt Counter64String,
l2PortTxFacilityCurrent1dayBytesFrames65Trmt Counter64String,
l2PortTxFacilityCurrent1dayBytesFrames128Trmt Counter64String,
l2PortTxFacilityCurrent1dayBytesFrames256Trmt Counter64String,
l2PortTxFacilityCurrent1dayBytesFrames512Trmt Counter64String,
l2PortTxFacilityCurrent1dayBytesFrames1024Trmt Counter64String,
l2PortTxFacilityCurrent1dayBytesFrames1519Trmt Counter64String,
l2PortTxFacilityCurrent1dayElapsedTime Integer32 }
l2PortTxFacilityCurrent1dayFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { l2PortTxFacilityCurrent1dayEntry 1 }
l2PortTxFacilityCurrent1dayBytesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { l2PortTxFacilityCurrent1dayEntry 2 }
l2PortTxFacilityCurrent1dayBroadcastFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Transmitted"
::= { l2PortTxFacilityCurrent1dayEntry 3 }
l2PortTxFacilityCurrent1dayMulticastFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { l2PortTxFacilityCurrent1dayEntry 4 }
l2PortTxFacilityCurrent1dayPauseFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { l2PortTxFacilityCurrent1dayEntry 5 }
l2PortTxFacilityCurrent1dayBytesFrames64Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent1dayEntry 6 }
l2PortTxFacilityCurrent1dayBytesFrames65Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent1dayEntry 7 }
l2PortTxFacilityCurrent1dayBytesFrames128Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent1dayEntry 8 }
l2PortTxFacilityCurrent1dayBytesFrames256Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent1dayEntry 9 }
l2PortTxFacilityCurrent1dayBytesFrames512Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent1dayEntry 10 }
l2PortTxFacilityCurrent1dayBytesFrames1024Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent1dayEntry 11 }
l2PortTxFacilityCurrent1dayBytesFrames1519Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Transmitted"
::= { l2PortTxFacilityCurrent1dayEntry 12 }
l2PortTxFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { l2PortTxFacilityCurrent1dayEntry 13 }
endOfL2PortTxFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 132 }
l2PortTxFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2PortTxFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 133 }
l2PortTxFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX L2PortTxFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
l2PortTxFacilityHistorical15minNumber
}
::= { l2PortTxFacilityHistorical15minTable 1 }
L2PortTxFacilityHistorical15minEntry ::= SEQUENCE
{ l2PortTxFacilityHistorical15minNumber Integer32,
l2PortTxFacilityHistorical15minFramesTrmt Counter64String,
l2PortTxFacilityHistorical15minBytesTrmt Counter64String,
l2PortTxFacilityHistorical15minBroadcastFramesTrmt Counter64String,
l2PortTxFacilityHistorical15minMulticastFramesTrmt Counter64String,
l2PortTxFacilityHistorical15minPauseFramesTrmt Counter64String,
l2PortTxFacilityHistorical15minBytesFrames64Trmt Counter64String,
l2PortTxFacilityHistorical15minBytesFrames65Trmt Counter64String,
l2PortTxFacilityHistorical15minBytesFrames128Trmt Counter64String,
l2PortTxFacilityHistorical15minBytesFrames256Trmt Counter64String,
l2PortTxFacilityHistorical15minBytesFrames512Trmt Counter64String,
l2PortTxFacilityHistorical15minBytesFrames1024Trmt Counter64String,
l2PortTxFacilityHistorical15minBytesFrames1519Trmt Counter64String,
l2PortTxFacilityHistorical15minValidFlag TruthValue,
l2PortTxFacilityHistorical15minTimeStamp DateAndTime }
l2PortTxFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { l2PortTxFacilityHistorical15minEntry 1 }
l2PortTxFacilityHistorical15minFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { l2PortTxFacilityHistorical15minEntry 2 }
l2PortTxFacilityHistorical15minBytesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { l2PortTxFacilityHistorical15minEntry 3 }
l2PortTxFacilityHistorical15minBroadcastFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Transmitted"
::= { l2PortTxFacilityHistorical15minEntry 4 }
l2PortTxFacilityHistorical15minMulticastFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { l2PortTxFacilityHistorical15minEntry 5 }
l2PortTxFacilityHistorical15minPauseFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { l2PortTxFacilityHistorical15minEntry 6 }
l2PortTxFacilityHistorical15minBytesFrames64Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical15minEntry 7 }
l2PortTxFacilityHistorical15minBytesFrames65Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical15minEntry 8 }
l2PortTxFacilityHistorical15minBytesFrames128Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical15minEntry 9 }
l2PortTxFacilityHistorical15minBytesFrames256Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical15minEntry 10 }
l2PortTxFacilityHistorical15minBytesFrames512Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical15minEntry 11 }
l2PortTxFacilityHistorical15minBytesFrames1024Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical15minEntry 12 }
l2PortTxFacilityHistorical15minBytesFrames1519Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical15minEntry 13 }
l2PortTxFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { l2PortTxFacilityHistorical15minEntry 14 }
l2PortTxFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { l2PortTxFacilityHistorical15minEntry 15 }
endOfL2PortTxFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 134 }
l2PortTxFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2PortTxFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 135 }
l2PortTxFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX L2PortTxFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
l2PortTxFacilityHistorical1dayNumber
}
::= { l2PortTxFacilityHistorical1dayTable 1 }
L2PortTxFacilityHistorical1dayEntry ::= SEQUENCE
{ l2PortTxFacilityHistorical1dayNumber Integer32,
l2PortTxFacilityHistorical1dayFramesTrmt Counter64String,
l2PortTxFacilityHistorical1dayBytesTrmt Counter64String,
l2PortTxFacilityHistorical1dayBroadcastFramesTrmt Counter64String,
l2PortTxFacilityHistorical1dayMulticastFramesTrmt Counter64String,
l2PortTxFacilityHistorical1dayPauseFramesTrmt Counter64String,
l2PortTxFacilityHistorical1dayBytesFrames64Trmt Counter64String,
l2PortTxFacilityHistorical1dayBytesFrames65Trmt Counter64String,
l2PortTxFacilityHistorical1dayBytesFrames128Trmt Counter64String,
l2PortTxFacilityHistorical1dayBytesFrames256Trmt Counter64String,
l2PortTxFacilityHistorical1dayBytesFrames512Trmt Counter64String,
l2PortTxFacilityHistorical1dayBytesFrames1024Trmt Counter64String,
l2PortTxFacilityHistorical1dayBytesFrames1519Trmt Counter64String,
l2PortTxFacilityHistorical1dayValidFlag TruthValue,
l2PortTxFacilityHistorical1dayTimeStamp DateAndTime }
l2PortTxFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { l2PortTxFacilityHistorical1dayEntry 1 }
l2PortTxFacilityHistorical1dayFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { l2PortTxFacilityHistorical1dayEntry 2 }
l2PortTxFacilityHistorical1dayBytesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { l2PortTxFacilityHistorical1dayEntry 3 }
l2PortTxFacilityHistorical1dayBroadcastFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Transmitted"
::= { l2PortTxFacilityHistorical1dayEntry 4 }
l2PortTxFacilityHistorical1dayMulticastFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { l2PortTxFacilityHistorical1dayEntry 5 }
l2PortTxFacilityHistorical1dayPauseFramesTrmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { l2PortTxFacilityHistorical1dayEntry 6 }
l2PortTxFacilityHistorical1dayBytesFrames64Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical1dayEntry 7 }
l2PortTxFacilityHistorical1dayBytesFrames65Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical1dayEntry 8 }
l2PortTxFacilityHistorical1dayBytesFrames128Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical1dayEntry 9 }
l2PortTxFacilityHistorical1dayBytesFrames256Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical1dayEntry 10 }
l2PortTxFacilityHistorical1dayBytesFrames512Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical1dayEntry 11 }
l2PortTxFacilityHistorical1dayBytesFrames1024Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical1dayEntry 12 }
l2PortTxFacilityHistorical1dayBytesFrames1519Trmt OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Transmitted"
::= { l2PortTxFacilityHistorical1dayEntry 13 }
l2PortTxFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { l2PortTxFacilityHistorical1dayEntry 14 }
l2PortTxFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { l2PortTxFacilityHistorical1dayEntry 15 }
endOfL2PortTxFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 136 }
l2PortRxFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2PortRxFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 137 }
l2PortRxFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX L2PortRxFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { l2PortRxFacilityCurrent15minTable 1 }
L2PortRxFacilityCurrent15minEntry ::= SEQUENCE
{ l2PortRxFacilityCurrent15minFramesRcv Counter64String,
l2PortRxFacilityCurrent15minBytesRcv Counter64String,
l2PortRxFacilityCurrent15minBroadcastFramesRcv Counter64String,
l2PortRxFacilityCurrent15minMulticastFramesRcv Counter64String,
l2PortRxFacilityCurrent15minCrcErrorsRcv Counter64String,
l2PortRxFacilityCurrent15minUndersizedFramesRcv Counter64String,
l2PortRxFacilityCurrent15minOversizedFramesRcv Counter64String,
l2PortRxFacilityCurrent15minPauseFramesRcv Counter64String,
l2PortRxFacilityCurrent15minBytesFrames64Rcv Counter64String,
l2PortRxFacilityCurrent15minBytesFrames65Rcv Counter64String,
l2PortRxFacilityCurrent15minBytesFrames128Rcv Counter64String,
l2PortRxFacilityCurrent15minBytesFrames256Rcv Counter64String,
l2PortRxFacilityCurrent15minBytesFrames512Rcv Counter64String,
l2PortRxFacilityCurrent15minBytesFrames1024Rcv Counter64String,
l2PortRxFacilityCurrent15minBytesFrames1519Rcv Counter64String,
l2PortRxFacilityCurrent15minInterPackJunkBytesFramesRcv Counter64String,
l2PortRxFacilityCurrent15minElapsedTime Integer32 }
l2PortRxFacilityCurrent15minFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 1 }
l2PortRxFacilityCurrent15minBytesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { l2PortRxFacilityCurrent15minEntry 2 }
l2PortRxFacilityCurrent15minBroadcastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 3 }
l2PortRxFacilityCurrent15minMulticastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 4 }
l2PortRxFacilityCurrent15minCrcErrorsRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { l2PortRxFacilityCurrent15minEntry 5 }
l2PortRxFacilityCurrent15minUndersizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Undersized Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 6 }
l2PortRxFacilityCurrent15minOversizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Oversized Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 7 }
l2PortRxFacilityCurrent15minPauseFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 8 }
l2PortRxFacilityCurrent15minBytesFrames64Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 9 }
l2PortRxFacilityCurrent15minBytesFrames65Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 10 }
l2PortRxFacilityCurrent15minBytesFrames128Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 11 }
l2PortRxFacilityCurrent15minBytesFrames256Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 12 }
l2PortRxFacilityCurrent15minBytesFrames512Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 13 }
l2PortRxFacilityCurrent15minBytesFrames1024Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 14 }
l2PortRxFacilityCurrent15minBytesFrames1519Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Received"
::= { l2PortRxFacilityCurrent15minEntry 15 }
l2PortRxFacilityCurrent15minInterPackJunkBytesFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"InterPackJunk Bytes Frames Received (10Gbit/s only)"
::= { l2PortRxFacilityCurrent15minEntry 16 }
l2PortRxFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { l2PortRxFacilityCurrent15minEntry 17 }
endOfL2PortRxFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 138 }
l2PortRxFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2PortRxFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 139 }
l2PortRxFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX L2PortRxFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { l2PortRxFacilityCurrent1dayTable 1 }
L2PortRxFacilityCurrent1dayEntry ::= SEQUENCE
{ l2PortRxFacilityCurrent1dayFramesRcv Counter64String,
l2PortRxFacilityCurrent1dayBytesRcv Counter64String,
l2PortRxFacilityCurrent1dayBroadcastFramesRcv Counter64String,
l2PortRxFacilityCurrent1dayMulticastFramesRcv Counter64String,
l2PortRxFacilityCurrent1dayCrcErrorsRcv Counter64String,
l2PortRxFacilityCurrent1dayUndersizedFramesRcv Counter64String,
l2PortRxFacilityCurrent1dayOversizedFramesRcv Counter64String,
l2PortRxFacilityCurrent1dayPauseFramesRcv Counter64String,
l2PortRxFacilityCurrent1dayBytesFrames64Rcv Counter64String,
l2PortRxFacilityCurrent1dayBytesFrames65Rcv Counter64String,
l2PortRxFacilityCurrent1dayBytesFrames128Rcv Counter64String,
l2PortRxFacilityCurrent1dayBytesFrames256Rcv Counter64String,
l2PortRxFacilityCurrent1dayBytesFrames512Rcv Counter64String,
l2PortRxFacilityCurrent1dayBytesFrames1024Rcv Counter64String,
l2PortRxFacilityCurrent1dayBytesFrames1519Rcv Counter64String,
l2PortRxFacilityCurrent1dayInterPackJunkBytesFramesRcv Counter64String,
l2PortRxFacilityCurrent1dayElapsedTime Integer32 }
l2PortRxFacilityCurrent1dayFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 1 }
l2PortRxFacilityCurrent1dayBytesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { l2PortRxFacilityCurrent1dayEntry 2 }
l2PortRxFacilityCurrent1dayBroadcastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 3 }
l2PortRxFacilityCurrent1dayMulticastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 4 }
l2PortRxFacilityCurrent1dayCrcErrorsRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { l2PortRxFacilityCurrent1dayEntry 5 }
l2PortRxFacilityCurrent1dayUndersizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Undersized Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 6 }
l2PortRxFacilityCurrent1dayOversizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Oversized Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 7 }
l2PortRxFacilityCurrent1dayPauseFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 8 }
l2PortRxFacilityCurrent1dayBytesFrames64Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 9 }
l2PortRxFacilityCurrent1dayBytesFrames65Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 10 }
l2PortRxFacilityCurrent1dayBytesFrames128Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 11 }
l2PortRxFacilityCurrent1dayBytesFrames256Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 12 }
l2PortRxFacilityCurrent1dayBytesFrames512Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 13 }
l2PortRxFacilityCurrent1dayBytesFrames1024Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 14 }
l2PortRxFacilityCurrent1dayBytesFrames1519Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Received"
::= { l2PortRxFacilityCurrent1dayEntry 15 }
l2PortRxFacilityCurrent1dayInterPackJunkBytesFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"InterPackJunk Bytes Frames Received (10Gbit/s only)"
::= { l2PortRxFacilityCurrent1dayEntry 16 }
l2PortRxFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { l2PortRxFacilityCurrent1dayEntry 17 }
endOfL2PortRxFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 140 }
l2PortRxFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2PortRxFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 141 }
l2PortRxFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX L2PortRxFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
l2PortRxFacilityHistorical15minNumber
}
::= { l2PortRxFacilityHistorical15minTable 1 }
L2PortRxFacilityHistorical15minEntry ::= SEQUENCE
{ l2PortRxFacilityHistorical15minNumber Integer32,
l2PortRxFacilityHistorical15minFramesRcv Counter64String,
l2PortRxFacilityHistorical15minBytesRcv Counter64String,
l2PortRxFacilityHistorical15minBroadcastFramesRcv Counter64String,
l2PortRxFacilityHistorical15minMulticastFramesRcv Counter64String,
l2PortRxFacilityHistorical15minCrcErrorsRcv Counter64String,
l2PortRxFacilityHistorical15minUndersizedFramesRcv Counter64String,
l2PortRxFacilityHistorical15minOversizedFramesRcv Counter64String,
l2PortRxFacilityHistorical15minPauseFramesRcv Counter64String,
l2PortRxFacilityHistorical15minBytesFrames64Rcv Counter64String,
l2PortRxFacilityHistorical15minBytesFrames65Rcv Counter64String,
l2PortRxFacilityHistorical15minBytesFrames128Rcv Counter64String,
l2PortRxFacilityHistorical15minBytesFrames256Rcv Counter64String,
l2PortRxFacilityHistorical15minBytesFrames512Rcv Counter64String,
l2PortRxFacilityHistorical15minBytesFrames1024Rcv Counter64String,
l2PortRxFacilityHistorical15minBytesFrames1519Rcv Counter64String,
l2PortRxFacilityHistorical15minInterPackJunkBytesFramesRcv Counter64String,
l2PortRxFacilityHistorical15minValidFlag TruthValue,
l2PortRxFacilityHistorical15minTimeStamp DateAndTime }
l2PortRxFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { l2PortRxFacilityHistorical15minEntry 1 }
l2PortRxFacilityHistorical15minFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 2 }
l2PortRxFacilityHistorical15minBytesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { l2PortRxFacilityHistorical15minEntry 3 }
l2PortRxFacilityHistorical15minBroadcastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 4 }
l2PortRxFacilityHistorical15minMulticastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 5 }
l2PortRxFacilityHistorical15minCrcErrorsRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { l2PortRxFacilityHistorical15minEntry 6 }
l2PortRxFacilityHistorical15minUndersizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Undersized Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 7 }
l2PortRxFacilityHistorical15minOversizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Oversized Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 8 }
l2PortRxFacilityHistorical15minPauseFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 9 }
l2PortRxFacilityHistorical15minBytesFrames64Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 10 }
l2PortRxFacilityHistorical15minBytesFrames65Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 11 }
l2PortRxFacilityHistorical15minBytesFrames128Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 12 }
l2PortRxFacilityHistorical15minBytesFrames256Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 13 }
l2PortRxFacilityHistorical15minBytesFrames512Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 14 }
l2PortRxFacilityHistorical15minBytesFrames1024Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 15 }
l2PortRxFacilityHistorical15minBytesFrames1519Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Received"
::= { l2PortRxFacilityHistorical15minEntry 16 }
l2PortRxFacilityHistorical15minInterPackJunkBytesFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"InterPackJunk Bytes Frames Received (10Gbit/s only)"
::= { l2PortRxFacilityHistorical15minEntry 17 }
l2PortRxFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { l2PortRxFacilityHistorical15minEntry 18 }
l2PortRxFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { l2PortRxFacilityHistorical15minEntry 19 }
endOfL2PortRxFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 142 }
l2PortRxFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2PortRxFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 143 }
l2PortRxFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX L2PortRxFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
l2PortRxFacilityHistorical1dayNumber
}
::= { l2PortRxFacilityHistorical1dayTable 1 }
L2PortRxFacilityHistorical1dayEntry ::= SEQUENCE
{ l2PortRxFacilityHistorical1dayNumber Integer32,
l2PortRxFacilityHistorical1dayFramesRcv Counter64String,
l2PortRxFacilityHistorical1dayBytesRcv Counter64String,
l2PortRxFacilityHistorical1dayBroadcastFramesRcv Counter64String,
l2PortRxFacilityHistorical1dayMulticastFramesRcv Counter64String,
l2PortRxFacilityHistorical1dayCrcErrorsRcv Counter64String,
l2PortRxFacilityHistorical1dayUndersizedFramesRcv Counter64String,
l2PortRxFacilityHistorical1dayOversizedFramesRcv Counter64String,
l2PortRxFacilityHistorical1dayPauseFramesRcv Counter64String,
l2PortRxFacilityHistorical1dayBytesFrames64Rcv Counter64String,
l2PortRxFacilityHistorical1dayBytesFrames65Rcv Counter64String,
l2PortRxFacilityHistorical1dayBytesFrames128Rcv Counter64String,
l2PortRxFacilityHistorical1dayBytesFrames256Rcv Counter64String,
l2PortRxFacilityHistorical1dayBytesFrames512Rcv Counter64String,
l2PortRxFacilityHistorical1dayBytesFrames1024Rcv Counter64String,
l2PortRxFacilityHistorical1dayBytesFrames1519Rcv Counter64String,
l2PortRxFacilityHistorical1dayInterPackJunkBytesFramesRcv Counter64String,
l2PortRxFacilityHistorical1dayValidFlag TruthValue,
l2PortRxFacilityHistorical1dayTimeStamp DateAndTime }
l2PortRxFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { l2PortRxFacilityHistorical1dayEntry 1 }
l2PortRxFacilityHistorical1dayFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 2 }
l2PortRxFacilityHistorical1dayBytesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { l2PortRxFacilityHistorical1dayEntry 3 }
l2PortRxFacilityHistorical1dayBroadcastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 4 }
l2PortRxFacilityHistorical1dayMulticastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 5 }
l2PortRxFacilityHistorical1dayCrcErrorsRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { l2PortRxFacilityHistorical1dayEntry 6 }
l2PortRxFacilityHistorical1dayUndersizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Undersized Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 7 }
l2PortRxFacilityHistorical1dayOversizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Oversized Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 8 }
l2PortRxFacilityHistorical1dayPauseFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 9 }
l2PortRxFacilityHistorical1dayBytesFrames64Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 10 }
l2PortRxFacilityHistorical1dayBytesFrames65Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 11 }
l2PortRxFacilityHistorical1dayBytesFrames128Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 12 }
l2PortRxFacilityHistorical1dayBytesFrames256Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 13 }
l2PortRxFacilityHistorical1dayBytesFrames512Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 14 }
l2PortRxFacilityHistorical1dayBytesFrames1024Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 15 }
l2PortRxFacilityHistorical1dayBytesFrames1519Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Received"
::= { l2PortRxFacilityHistorical1dayEntry 16 }
l2PortRxFacilityHistorical1dayInterPackJunkBytesFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"InterPackJunk Bytes Frames Received (10Gbit/s only)"
::= { l2PortRxFacilityHistorical1dayEntry 17 }
l2PortRxFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { l2PortRxFacilityHistorical1dayEntry 18 }
l2PortRxFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { l2PortRxFacilityHistorical1dayEntry 19 }
endOfL2PortRxFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 144 }
frRcv1FacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv1FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 145 }
frRcv1FacilityCurrent15minEntry OBJECT-TYPE
SYNTAX FrRcv1FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { frRcv1FacilityCurrent15minTable 1 }
FrRcv1FacilityCurrent15minEntry ::= SEQUENCE
{ frRcv1FacilityCurrent15minGoodFrames Counter64String,
frRcv1FacilityCurrent15minPauseFrames Counter64String,
frRcv1FacilityCurrent15minCrcFrames Counter64String,
frRcv1FacilityCurrent15minDiscardedFrames Counter64String,
frRcv1FacilityCurrent15minBytes Counter64String,
frRcv1FacilityCurrent15minElapsedTime Integer32 }
frRcv1FacilityCurrent15minGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv1FacilityCurrent15minEntry 1 }
frRcv1FacilityCurrent15minPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv1FacilityCurrent15minEntry 2 }
frRcv1FacilityCurrent15minCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv1FacilityCurrent15minEntry 3 }
frRcv1FacilityCurrent15minDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received Frames Discarded"
::= { frRcv1FacilityCurrent15minEntry 4 }
frRcv1FacilityCurrent15minBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv1FacilityCurrent15minEntry 5 }
frRcv1FacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { frRcv1FacilityCurrent15minEntry 6 }
endOfFrRcv1FacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 146 }
frRcv1FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv1FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 147 }
frRcv1FacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX FrRcv1FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { frRcv1FacilityCurrent1dayTable 1 }
FrRcv1FacilityCurrent1dayEntry ::= SEQUENCE
{ frRcv1FacilityCurrent1dayGoodFrames Counter64String,
frRcv1FacilityCurrent1dayPauseFrames Counter64String,
frRcv1FacilityCurrent1dayCrcFrames Counter64String,
frRcv1FacilityCurrent1dayDiscardedFrames Counter64String,
frRcv1FacilityCurrent1dayBytes Counter64String,
frRcv1FacilityCurrent1dayElapsedTime Integer32 }
frRcv1FacilityCurrent1dayGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv1FacilityCurrent1dayEntry 1 }
frRcv1FacilityCurrent1dayPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv1FacilityCurrent1dayEntry 2 }
frRcv1FacilityCurrent1dayCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv1FacilityCurrent1dayEntry 3 }
frRcv1FacilityCurrent1dayDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received Frames Discarded"
::= { frRcv1FacilityCurrent1dayEntry 4 }
frRcv1FacilityCurrent1dayBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv1FacilityCurrent1dayEntry 5 }
frRcv1FacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { frRcv1FacilityCurrent1dayEntry 6 }
endOfFrRcv1FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 148 }
frRcv1FacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv1FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 149 }
frRcv1FacilityHistorical15minEntry OBJECT-TYPE
SYNTAX FrRcv1FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
frRcv1FacilityHistorical15minNumber
}
::= { frRcv1FacilityHistorical15minTable 1 }
FrRcv1FacilityHistorical15minEntry ::= SEQUENCE
{ frRcv1FacilityHistorical15minNumber Integer32,
frRcv1FacilityHistorical15minGoodFrames Counter64String,
frRcv1FacilityHistorical15minPauseFrames Counter64String,
frRcv1FacilityHistorical15minCrcFrames Counter64String,
frRcv1FacilityHistorical15minDiscardedFrames Counter64String,
frRcv1FacilityHistorical15minBytes Counter64String,
frRcv1FacilityHistorical15minValidFlag TruthValue,
frRcv1FacilityHistorical15minTimeStamp DateAndTime }
frRcv1FacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { frRcv1FacilityHistorical15minEntry 1 }
frRcv1FacilityHistorical15minGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv1FacilityHistorical15minEntry 2 }
frRcv1FacilityHistorical15minPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv1FacilityHistorical15minEntry 3 }
frRcv1FacilityHistorical15minCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv1FacilityHistorical15minEntry 4 }
frRcv1FacilityHistorical15minDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received Frames Discarded"
::= { frRcv1FacilityHistorical15minEntry 5 }
frRcv1FacilityHistorical15minBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv1FacilityHistorical15minEntry 6 }
frRcv1FacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { frRcv1FacilityHistorical15minEntry 7 }
frRcv1FacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { frRcv1FacilityHistorical15minEntry 8 }
endOfFrRcv1FacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 150 }
frRcv1FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv1FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 151 }
frRcv1FacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX FrRcv1FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
frRcv1FacilityHistorical1dayNumber
}
::= { frRcv1FacilityHistorical1dayTable 1 }
FrRcv1FacilityHistorical1dayEntry ::= SEQUENCE
{ frRcv1FacilityHistorical1dayNumber Integer32,
frRcv1FacilityHistorical1dayGoodFrames Counter64String,
frRcv1FacilityHistorical1dayPauseFrames Counter64String,
frRcv1FacilityHistorical1dayCrcFrames Counter64String,
frRcv1FacilityHistorical1dayDiscardedFrames Counter64String,
frRcv1FacilityHistorical1dayBytes Counter64String,
frRcv1FacilityHistorical1dayValidFlag TruthValue,
frRcv1FacilityHistorical1dayTimeStamp DateAndTime }
frRcv1FacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { frRcv1FacilityHistorical1dayEntry 1 }
frRcv1FacilityHistorical1dayGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv1FacilityHistorical1dayEntry 2 }
frRcv1FacilityHistorical1dayPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv1FacilityHistorical1dayEntry 3 }
frRcv1FacilityHistorical1dayCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv1FacilityHistorical1dayEntry 4 }
frRcv1FacilityHistorical1dayDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received Frames Discarded"
::= { frRcv1FacilityHistorical1dayEntry 5 }
frRcv1FacilityHistorical1dayBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv1FacilityHistorical1dayEntry 6 }
frRcv1FacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { frRcv1FacilityHistorical1dayEntry 7 }
frRcv1FacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { frRcv1FacilityHistorical1dayEntry 8 }
endOfFrRcv1FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 152 }
frRcv2FacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv2FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 153 }
frRcv2FacilityCurrent15minEntry OBJECT-TYPE
SYNTAX FrRcv2FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { frRcv2FacilityCurrent15minTable 1 }
FrRcv2FacilityCurrent15minEntry ::= SEQUENCE
{ frRcv2FacilityCurrent15minGoodFrames Counter64String,
frRcv2FacilityCurrent15minPauseFrames Counter64String,
frRcv2FacilityCurrent15minCrcFrames Counter64String,
frRcv2FacilityCurrent15minBytes Counter64String,
frRcv2FacilityCurrent15minElapsedTime Integer32 }
frRcv2FacilityCurrent15minGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv2FacilityCurrent15minEntry 1 }
frRcv2FacilityCurrent15minPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv2FacilityCurrent15minEntry 2 }
frRcv2FacilityCurrent15minCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv2FacilityCurrent15minEntry 3 }
frRcv2FacilityCurrent15minBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv2FacilityCurrent15minEntry 4 }
frRcv2FacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { frRcv2FacilityCurrent15minEntry 5 }
endOfFrRcv2FacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 154 }
frRcv2FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv2FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 155 }
frRcv2FacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX FrRcv2FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { frRcv2FacilityCurrent1dayTable 1 }
FrRcv2FacilityCurrent1dayEntry ::= SEQUENCE
{ frRcv2FacilityCurrent1dayGoodFrames Counter64String,
frRcv2FacilityCurrent1dayPauseFrames Counter64String,
frRcv2FacilityCurrent1dayCrcFrames Counter64String,
frRcv2FacilityCurrent1dayBytes Counter64String,
frRcv2FacilityCurrent1dayElapsedTime Integer32 }
frRcv2FacilityCurrent1dayGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv2FacilityCurrent1dayEntry 1 }
frRcv2FacilityCurrent1dayPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv2FacilityCurrent1dayEntry 2 }
frRcv2FacilityCurrent1dayCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv2FacilityCurrent1dayEntry 3 }
frRcv2FacilityCurrent1dayBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv2FacilityCurrent1dayEntry 4 }
frRcv2FacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { frRcv2FacilityCurrent1dayEntry 5 }
endOfFrRcv2FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 156 }
frRcv2FacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv2FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 157 }
frRcv2FacilityHistorical15minEntry OBJECT-TYPE
SYNTAX FrRcv2FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
frRcv2FacilityHistorical15minNumber
}
::= { frRcv2FacilityHistorical15minTable 1 }
FrRcv2FacilityHistorical15minEntry ::= SEQUENCE
{ frRcv2FacilityHistorical15minNumber Integer32,
frRcv2FacilityHistorical15minGoodFrames Counter64String,
frRcv2FacilityHistorical15minPauseFrames Counter64String,
frRcv2FacilityHistorical15minCrcFrames Counter64String,
frRcv2FacilityHistorical15minBytes Counter64String,
frRcv2FacilityHistorical15minValidFlag TruthValue,
frRcv2FacilityHistorical15minTimeStamp DateAndTime }
frRcv2FacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { frRcv2FacilityHistorical15minEntry 1 }
frRcv2FacilityHistorical15minGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv2FacilityHistorical15minEntry 2 }
frRcv2FacilityHistorical15minPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv2FacilityHistorical15minEntry 3 }
frRcv2FacilityHistorical15minCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv2FacilityHistorical15minEntry 4 }
frRcv2FacilityHistorical15minBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv2FacilityHistorical15minEntry 5 }
frRcv2FacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { frRcv2FacilityHistorical15minEntry 6 }
frRcv2FacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { frRcv2FacilityHistorical15minEntry 7 }
endOfFrRcv2FacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 158 }
frRcv2FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv2FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 159 }
frRcv2FacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX FrRcv2FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
frRcv2FacilityHistorical1dayNumber
}
::= { frRcv2FacilityHistorical1dayTable 1 }
FrRcv2FacilityHistorical1dayEntry ::= SEQUENCE
{ frRcv2FacilityHistorical1dayNumber Integer32,
frRcv2FacilityHistorical1dayGoodFrames Counter64String,
frRcv2FacilityHistorical1dayPauseFrames Counter64String,
frRcv2FacilityHistorical1dayCrcFrames Counter64String,
frRcv2FacilityHistorical1dayBytes Counter64String,
frRcv2FacilityHistorical1dayValidFlag TruthValue,
frRcv2FacilityHistorical1dayTimeStamp DateAndTime }
frRcv2FacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { frRcv2FacilityHistorical1dayEntry 1 }
frRcv2FacilityHistorical1dayGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv2FacilityHistorical1dayEntry 2 }
frRcv2FacilityHistorical1dayPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv2FacilityHistorical1dayEntry 3 }
frRcv2FacilityHistorical1dayCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv2FacilityHistorical1dayEntry 4 }
frRcv2FacilityHistorical1dayBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv2FacilityHistorical1dayEntry 5 }
frRcv2FacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { frRcv2FacilityHistorical1dayEntry 6 }
frRcv2FacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { frRcv2FacilityHistorical1dayEntry 7 }
endOfFrRcv2FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 160 }
frRcv3FacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv3FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 161 }
frRcv3FacilityCurrent15minEntry OBJECT-TYPE
SYNTAX FrRcv3FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { frRcv3FacilityCurrent15minTable 1 }
FrRcv3FacilityCurrent15minEntry ::= SEQUENCE
{ frRcv3FacilityCurrent15minGoodFrames Counter64String,
frRcv3FacilityCurrent15minPauseFrames Counter64String,
frRcv3FacilityCurrent15minCrcFrames Counter64String,
frRcv3FacilityCurrent15minBytes Counter64String,
frRcv3FacilityCurrent15minBroadcastFramesRcv Counter64String,
frRcv3FacilityCurrent15minMulticastFramesRcv Counter64String,
frRcv3FacilityCurrent15minUndersizedFramesRcv Counter64String,
frRcv3FacilityCurrent15minOversizedFramesRcv Counter64String,
frRcv3FacilityCurrent15minFragmentFramesRcv Counter64String,
frRcv3FacilityCurrent15minJabberFrameRcv Counter64String,
frRcv3FacilityCurrent15minControlFrameRcv Counter64String,
frRcv3FacilityCurrent15minBytesFrames64Rcv Counter64String,
frRcv3FacilityCurrent15minBytesFrames65Rcv Counter64String,
frRcv3FacilityCurrent15minBytesFrames128Rcv Counter64String,
frRcv3FacilityCurrent15minBytesFrames256Rcv Counter64String,
frRcv3FacilityCurrent15minBytesFrames512Rcv Counter64String,
frRcv3FacilityCurrent15minBytesFrames1024Rcv Counter64String,
frRcv3FacilityCurrent15minBytesFrames1519Rcv Counter64String,
frRcv3FacilityCurrent15minElapsedTime Integer32 }
frRcv3FacilityCurrent15minGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv3FacilityCurrent15minEntry 1 }
frRcv3FacilityCurrent15minPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv3FacilityCurrent15minEntry 2 }
frRcv3FacilityCurrent15minCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv3FacilityCurrent15minEntry 3 }
frRcv3FacilityCurrent15minBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv3FacilityCurrent15minEntry 4 }
frRcv3FacilityCurrent15minBroadcastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Received"
::= { frRcv3FacilityCurrent15minEntry 5 }
frRcv3FacilityCurrent15minMulticastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { frRcv3FacilityCurrent15minEntry 6 }
frRcv3FacilityCurrent15minUndersizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Undersized Frames Received"
::= { frRcv3FacilityCurrent15minEntry 7 }
frRcv3FacilityCurrent15minOversizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Oversized Frames Received"
::= { frRcv3FacilityCurrent15minEntry 8 }
frRcv3FacilityCurrent15minFragmentFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fragment Frames Received"
::= { frRcv3FacilityCurrent15minEntry 9 }
frRcv3FacilityCurrent15minJabberFrameRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Jabber Frame"
::= { frRcv3FacilityCurrent15minEntry 10 }
frRcv3FacilityCurrent15minControlFrameRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Control Frames Received"
::= { frRcv3FacilityCurrent15minEntry 11 }
frRcv3FacilityCurrent15minBytesFrames64Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Received"
::= { frRcv3FacilityCurrent15minEntry 12 }
frRcv3FacilityCurrent15minBytesFrames65Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Received"
::= { frRcv3FacilityCurrent15minEntry 13 }
frRcv3FacilityCurrent15minBytesFrames128Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Received"
::= { frRcv3FacilityCurrent15minEntry 14 }
frRcv3FacilityCurrent15minBytesFrames256Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Received"
::= { frRcv3FacilityCurrent15minEntry 15 }
frRcv3FacilityCurrent15minBytesFrames512Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Received"
::= { frRcv3FacilityCurrent15minEntry 16 }
frRcv3FacilityCurrent15minBytesFrames1024Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Received"
::= { frRcv3FacilityCurrent15minEntry 17 }
frRcv3FacilityCurrent15minBytesFrames1519Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Received"
::= { frRcv3FacilityCurrent15minEntry 18 }
frRcv3FacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { frRcv3FacilityCurrent15minEntry 19 }
endOfFrRcv3FacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 162 }
frRcv3FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv3FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 163 }
frRcv3FacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX FrRcv3FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { frRcv3FacilityCurrent1dayTable 1 }
FrRcv3FacilityCurrent1dayEntry ::= SEQUENCE
{ frRcv3FacilityCurrent1dayGoodFrames Counter64String,
frRcv3FacilityCurrent1dayPauseFrames Counter64String,
frRcv3FacilityCurrent1dayCrcFrames Counter64String,
frRcv3FacilityCurrent1dayBytes Counter64String,
frRcv3FacilityCurrent1dayBroadcastFramesRcv Counter64String,
frRcv3FacilityCurrent1dayMulticastFramesRcv Counter64String,
frRcv3FacilityCurrent1dayUndersizedFramesRcv Counter64String,
frRcv3FacilityCurrent1dayOversizedFramesRcv Counter64String,
frRcv3FacilityCurrent1dayFragmentFramesRcv Counter64String,
frRcv3FacilityCurrent1dayJabberFrameRcv Counter64String,
frRcv3FacilityCurrent1dayControlFrameRcv Counter64String,
frRcv3FacilityCurrent1dayBytesFrames64Rcv Counter64String,
frRcv3FacilityCurrent1dayBytesFrames65Rcv Counter64String,
frRcv3FacilityCurrent1dayBytesFrames128Rcv Counter64String,
frRcv3FacilityCurrent1dayBytesFrames256Rcv Counter64String,
frRcv3FacilityCurrent1dayBytesFrames512Rcv Counter64String,
frRcv3FacilityCurrent1dayBytesFrames1024Rcv Counter64String,
frRcv3FacilityCurrent1dayBytesFrames1519Rcv Counter64String,
frRcv3FacilityCurrent1dayElapsedTime Integer32 }
frRcv3FacilityCurrent1dayGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 1 }
frRcv3FacilityCurrent1dayPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 2 }
frRcv3FacilityCurrent1dayCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv3FacilityCurrent1dayEntry 3 }
frRcv3FacilityCurrent1dayBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv3FacilityCurrent1dayEntry 4 }
frRcv3FacilityCurrent1dayBroadcastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 5 }
frRcv3FacilityCurrent1dayMulticastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 6 }
frRcv3FacilityCurrent1dayUndersizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Undersized Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 7 }
frRcv3FacilityCurrent1dayOversizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Oversized Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 8 }
frRcv3FacilityCurrent1dayFragmentFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fragment Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 9 }
frRcv3FacilityCurrent1dayJabberFrameRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Jabber Frame"
::= { frRcv3FacilityCurrent1dayEntry 10 }
frRcv3FacilityCurrent1dayControlFrameRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Control Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 11 }
frRcv3FacilityCurrent1dayBytesFrames64Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 12 }
frRcv3FacilityCurrent1dayBytesFrames65Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 13 }
frRcv3FacilityCurrent1dayBytesFrames128Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 14 }
frRcv3FacilityCurrent1dayBytesFrames256Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 15 }
frRcv3FacilityCurrent1dayBytesFrames512Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 16 }
frRcv3FacilityCurrent1dayBytesFrames1024Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 17 }
frRcv3FacilityCurrent1dayBytesFrames1519Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Received"
::= { frRcv3FacilityCurrent1dayEntry 18 }
frRcv3FacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { frRcv3FacilityCurrent1dayEntry 19 }
endOfFrRcv3FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 164 }
frRcv3FacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv3FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 165 }
frRcv3FacilityHistorical15minEntry OBJECT-TYPE
SYNTAX FrRcv3FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
frRcv3FacilityHistorical15minNumber
}
::= { frRcv3FacilityHistorical15minTable 1 }
FrRcv3FacilityHistorical15minEntry ::= SEQUENCE
{ frRcv3FacilityHistorical15minNumber Integer32,
frRcv3FacilityHistorical15minGoodFrames Counter64String,
frRcv3FacilityHistorical15minPauseFrames Counter64String,
frRcv3FacilityHistorical15minCrcFrames Counter64String,
frRcv3FacilityHistorical15minBytes Counter64String,
frRcv3FacilityHistorical15minBroadcastFramesRcv Counter64String,
frRcv3FacilityHistorical15minMulticastFramesRcv Counter64String,
frRcv3FacilityHistorical15minUndersizedFramesRcv Counter64String,
frRcv3FacilityHistorical15minOversizedFramesRcv Counter64String,
frRcv3FacilityHistorical15minFragmentFramesRcv Counter64String,
frRcv3FacilityHistorical15minJabberFrameRcv Counter64String,
frRcv3FacilityHistorical15minControlFrameRcv Counter64String,
frRcv3FacilityHistorical15minBytesFrames64Rcv Counter64String,
frRcv3FacilityHistorical15minBytesFrames65Rcv Counter64String,
frRcv3FacilityHistorical15minBytesFrames128Rcv Counter64String,
frRcv3FacilityHistorical15minBytesFrames256Rcv Counter64String,
frRcv3FacilityHistorical15minBytesFrames512Rcv Counter64String,
frRcv3FacilityHistorical15minBytesFrames1024Rcv Counter64String,
frRcv3FacilityHistorical15minBytesFrames1519Rcv Counter64String,
frRcv3FacilityHistorical15minValidFlag TruthValue,
frRcv3FacilityHistorical15minTimeStamp DateAndTime }
frRcv3FacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { frRcv3FacilityHistorical15minEntry 1 }
frRcv3FacilityHistorical15minGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv3FacilityHistorical15minEntry 2 }
frRcv3FacilityHistorical15minPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv3FacilityHistorical15minEntry 3 }
frRcv3FacilityHistorical15minCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv3FacilityHistorical15minEntry 4 }
frRcv3FacilityHistorical15minBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv3FacilityHistorical15minEntry 5 }
frRcv3FacilityHistorical15minBroadcastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Received"
::= { frRcv3FacilityHistorical15minEntry 6 }
frRcv3FacilityHistorical15minMulticastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { frRcv3FacilityHistorical15minEntry 7 }
frRcv3FacilityHistorical15minUndersizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Undersized Frames Received"
::= { frRcv3FacilityHistorical15minEntry 8 }
frRcv3FacilityHistorical15minOversizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Oversized Frames Received"
::= { frRcv3FacilityHistorical15minEntry 9 }
frRcv3FacilityHistorical15minFragmentFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fragment Frames Received"
::= { frRcv3FacilityHistorical15minEntry 10 }
frRcv3FacilityHistorical15minJabberFrameRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Jabber Frame"
::= { frRcv3FacilityHistorical15minEntry 11 }
frRcv3FacilityHistorical15minControlFrameRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Control Frames Received"
::= { frRcv3FacilityHistorical15minEntry 12 }
frRcv3FacilityHistorical15minBytesFrames64Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Received"
::= { frRcv3FacilityHistorical15minEntry 13 }
frRcv3FacilityHistorical15minBytesFrames65Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Received"
::= { frRcv3FacilityHistorical15minEntry 14 }
frRcv3FacilityHistorical15minBytesFrames128Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Received"
::= { frRcv3FacilityHistorical15minEntry 15 }
frRcv3FacilityHistorical15minBytesFrames256Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Received"
::= { frRcv3FacilityHistorical15minEntry 16 }
frRcv3FacilityHistorical15minBytesFrames512Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Received"
::= { frRcv3FacilityHistorical15minEntry 17 }
frRcv3FacilityHistorical15minBytesFrames1024Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Received"
::= { frRcv3FacilityHistorical15minEntry 18 }
frRcv3FacilityHistorical15minBytesFrames1519Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Received"
::= { frRcv3FacilityHistorical15minEntry 19 }
frRcv3FacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { frRcv3FacilityHistorical15minEntry 20 }
frRcv3FacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { frRcv3FacilityHistorical15minEntry 21 }
endOfFrRcv3FacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 166 }
frRcv3FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrRcv3FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 167 }
frRcv3FacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX FrRcv3FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
frRcv3FacilityHistorical1dayNumber
}
::= { frRcv3FacilityHistorical1dayTable 1 }
FrRcv3FacilityHistorical1dayEntry ::= SEQUENCE
{ frRcv3FacilityHistorical1dayNumber Integer32,
frRcv3FacilityHistorical1dayGoodFrames Counter64String,
frRcv3FacilityHistorical1dayPauseFrames Counter64String,
frRcv3FacilityHistorical1dayCrcFrames Counter64String,
frRcv3FacilityHistorical1dayBytes Counter64String,
frRcv3FacilityHistorical1dayBroadcastFramesRcv Counter64String,
frRcv3FacilityHistorical1dayMulticastFramesRcv Counter64String,
frRcv3FacilityHistorical1dayUndersizedFramesRcv Counter64String,
frRcv3FacilityHistorical1dayOversizedFramesRcv Counter64String,
frRcv3FacilityHistorical1dayFragmentFramesRcv Counter64String,
frRcv3FacilityHistorical1dayJabberFrameRcv Counter64String,
frRcv3FacilityHistorical1dayControlFrameRcv Counter64String,
frRcv3FacilityHistorical1dayBytesFrames64Rcv Counter64String,
frRcv3FacilityHistorical1dayBytesFrames65Rcv Counter64String,
frRcv3FacilityHistorical1dayBytesFrames128Rcv Counter64String,
frRcv3FacilityHistorical1dayBytesFrames256Rcv Counter64String,
frRcv3FacilityHistorical1dayBytesFrames512Rcv Counter64String,
frRcv3FacilityHistorical1dayBytesFrames1024Rcv Counter64String,
frRcv3FacilityHistorical1dayBytesFrames1519Rcv Counter64String,
frRcv3FacilityHistorical1dayValidFlag TruthValue,
frRcv3FacilityHistorical1dayTimeStamp DateAndTime }
frRcv3FacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { frRcv3FacilityHistorical1dayEntry 1 }
frRcv3FacilityHistorical1dayGoodFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 2 }
frRcv3FacilityHistorical1dayPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 3 }
frRcv3FacilityHistorical1dayCrcFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC Errors"
::= { frRcv3FacilityHistorical1dayEntry 4 }
frRcv3FacilityHistorical1dayBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Received"
::= { frRcv3FacilityHistorical1dayEntry 5 }
frRcv3FacilityHistorical1dayBroadcastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Broadcast Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 6 }
frRcv3FacilityHistorical1dayMulticastFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multicast Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 7 }
frRcv3FacilityHistorical1dayUndersizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Undersized Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 8 }
frRcv3FacilityHistorical1dayOversizedFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Oversized Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 9 }
frRcv3FacilityHistorical1dayFragmentFramesRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fragment Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 10 }
frRcv3FacilityHistorical1dayJabberFrameRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Jabber Frame"
::= { frRcv3FacilityHistorical1dayEntry 11 }
frRcv3FacilityHistorical1dayControlFrameRcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Control Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 12 }
frRcv3FacilityHistorical1dayBytesFrames64Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"64 Byte Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 13 }
frRcv3FacilityHistorical1dayBytesFrames65Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"65-127 Byte Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 14 }
frRcv3FacilityHistorical1dayBytesFrames128Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"128-255 Byte Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 15 }
frRcv3FacilityHistorical1dayBytesFrames256Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"256-511 Byte Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 16 }
frRcv3FacilityHistorical1dayBytesFrames512Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"512-1023 Byte Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 17 }
frRcv3FacilityHistorical1dayBytesFrames1024Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1024-1518 Byte Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 18 }
frRcv3FacilityHistorical1dayBytesFrames1519Rcv OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1519-Max Byte Frames Received"
::= { frRcv3FacilityHistorical1dayEntry 19 }
frRcv3FacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { frRcv3FacilityHistorical1dayEntry 20 }
frRcv3FacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { frRcv3FacilityHistorical1dayEntry 21 }
endOfFrRcv3FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 168 }
dsFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 169 }
dsFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX DsFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { dsFacilityCurrent15minTable 1 }
DsFacilityCurrent15minEntry ::= SEQUENCE
{ dsFacilityCurrent15minDS Unsigned32,
dsFacilityCurrent15minElapsedTime Integer32 }
dsFacilityCurrent15minDS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defect Seconds"
::= { dsFacilityCurrent15minEntry 1 }
dsFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { dsFacilityCurrent15minEntry 2 }
endOfDsFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 170 }
dsFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 171 }
dsFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX DsFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { dsFacilityCurrent1dayTable 1 }
DsFacilityCurrent1dayEntry ::= SEQUENCE
{ dsFacilityCurrent1dayDS Unsigned32,
dsFacilityCurrent1dayElapsedTime Integer32 }
dsFacilityCurrent1dayDS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defect Seconds"
::= { dsFacilityCurrent1dayEntry 1 }
dsFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { dsFacilityCurrent1dayEntry 2 }
endOfDsFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 172 }
dsFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 173 }
dsFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX DsFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
dsFacilityHistorical15minNumber
}
::= { dsFacilityHistorical15minTable 1 }
DsFacilityHistorical15minEntry ::= SEQUENCE
{ dsFacilityHistorical15minNumber Integer32,
dsFacilityHistorical15minDS Unsigned32,
dsFacilityHistorical15minValidFlag TruthValue,
dsFacilityHistorical15minTimeStamp DateAndTime }
dsFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { dsFacilityHistorical15minEntry 1 }
dsFacilityHistorical15minDS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defect Seconds"
::= { dsFacilityHistorical15minEntry 2 }
dsFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { dsFacilityHistorical15minEntry 3 }
dsFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { dsFacilityHistorical15minEntry 4 }
endOfDsFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 174 }
dsFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 175 }
dsFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX DsFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
dsFacilityHistorical1dayNumber
}
::= { dsFacilityHistorical1dayTable 1 }
DsFacilityHistorical1dayEntry ::= SEQUENCE
{ dsFacilityHistorical1dayNumber Integer32,
dsFacilityHistorical1dayDS Unsigned32,
dsFacilityHistorical1dayValidFlag TruthValue,
dsFacilityHistorical1dayTimeStamp DateAndTime }
dsFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { dsFacilityHistorical1dayEntry 1 }
dsFacilityHistorical1dayDS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defect Seconds"
::= { dsFacilityHistorical1dayEntry 2 }
dsFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { dsFacilityHistorical1dayEntry 3 }
dsFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { dsFacilityHistorical1dayEntry 4 }
endOfDsFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 176 }
muxFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF MuxFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 177 }
muxFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX MuxFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { muxFacilityCurrent15minTable 1 }
MuxFacilityCurrent15minEntry ::= SEQUENCE
{ muxFacilityCurrent15minES Unsigned32,
muxFacilityCurrent15minSES Unsigned32,
muxFacilityCurrent15minCrc Unsigned32,
muxFacilityCurrent15minElapsedTime Integer32 }
muxFacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Errored Seconds"
::= { muxFacilityCurrent15minEntry 1 }
muxFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Severely Errored Seconds"
::= { muxFacilityCurrent15minEntry 2 }
muxFacilityCurrent15minCrc OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Cyclic Redundancy Check Errors"
::= { muxFacilityCurrent15minEntry 3 }
muxFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { muxFacilityCurrent15minEntry 4 }
endOfMuxFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 178 }
muxFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF MuxFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 179 }
muxFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX MuxFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { muxFacilityCurrent1dayTable 1 }
MuxFacilityCurrent1dayEntry ::= SEQUENCE
{ muxFacilityCurrent1dayES Unsigned32,
muxFacilityCurrent1daySES Unsigned32,
muxFacilityCurrent1dayCrc Unsigned32,
muxFacilityCurrent1dayElapsedTime Integer32 }
muxFacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Errored Seconds"
::= { muxFacilityCurrent1dayEntry 1 }
muxFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Severely Errored Seconds"
::= { muxFacilityCurrent1dayEntry 2 }
muxFacilityCurrent1dayCrc OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Cyclic Redundancy Check Errors"
::= { muxFacilityCurrent1dayEntry 3 }
muxFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { muxFacilityCurrent1dayEntry 4 }
endOfMuxFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 180 }
muxFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF MuxFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 181 }
muxFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX MuxFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
muxFacilityHistorical15minNumber
}
::= { muxFacilityHistorical15minTable 1 }
MuxFacilityHistorical15minEntry ::= SEQUENCE
{ muxFacilityHistorical15minNumber Integer32,
muxFacilityHistorical15minES Unsigned32,
muxFacilityHistorical15minSES Unsigned32,
muxFacilityHistorical15minCrc Unsigned32,
muxFacilityHistorical15minValidFlag TruthValue,
muxFacilityHistorical15minTimeStamp DateAndTime }
muxFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { muxFacilityHistorical15minEntry 1 }
muxFacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Errored Seconds"
::= { muxFacilityHistorical15minEntry 2 }
muxFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Severely Errored Seconds"
::= { muxFacilityHistorical15minEntry 3 }
muxFacilityHistorical15minCrc OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Cyclic Redundancy Check Errors"
::= { muxFacilityHistorical15minEntry 4 }
muxFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { muxFacilityHistorical15minEntry 5 }
muxFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { muxFacilityHistorical15minEntry 6 }
endOfMuxFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 182 }
muxFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF MuxFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 183 }
muxFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX MuxFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
muxFacilityHistorical1dayNumber
}
::= { muxFacilityHistorical1dayTable 1 }
MuxFacilityHistorical1dayEntry ::= SEQUENCE
{ muxFacilityHistorical1dayNumber Integer32,
muxFacilityHistorical1dayES Unsigned32,
muxFacilityHistorical1daySES Unsigned32,
muxFacilityHistorical1dayCrc Unsigned32,
muxFacilityHistorical1dayValidFlag TruthValue,
muxFacilityHistorical1dayTimeStamp DateAndTime }
muxFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { muxFacilityHistorical1dayEntry 1 }
muxFacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Errored Seconds"
::= { muxFacilityHistorical1dayEntry 2 }
muxFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Severely Errored Seconds"
::= { muxFacilityHistorical1dayEntry 3 }
muxFacilityHistorical1dayCrc OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexer Cyclic Redundancy Check Errors"
::= { muxFacilityHistorical1dayEntry 4 }
muxFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { muxFacilityHistorical1dayEntry 5 }
muxFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { muxFacilityHistorical1dayEntry 6 }
endOfMuxFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 184 }
frTrmt1FacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrTrmt1FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 185 }
frTrmt1FacilityCurrent15minEntry OBJECT-TYPE
SYNTAX FrTrmt1FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { frTrmt1FacilityCurrent15minTable 1 }
FrTrmt1FacilityCurrent15minEntry ::= SEQUENCE
{ frTrmt1FacilityCurrent15minGoodFramesx Counter64String,
frTrmt1FacilityCurrent15minPauseFrames Counter64String,
frTrmt1FacilityCurrent15minBytes Counter64String,
frTrmt1FacilityCurrent15minCrcFramesEgress Counter64String,
frTrmt1FacilityCurrent15minElapsedTime Integer32 }
frTrmt1FacilityCurrent15minGoodFramesx OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { frTrmt1FacilityCurrent15minEntry 1 }
frTrmt1FacilityCurrent15minPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { frTrmt1FacilityCurrent15minEntry 2 }
frTrmt1FacilityCurrent15minBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { frTrmt1FacilityCurrent15minEntry 3 }
frTrmt1FacilityCurrent15minCrcFramesEgress OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress CRC Errored Frames"
::= { frTrmt1FacilityCurrent15minEntry 4 }
frTrmt1FacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { frTrmt1FacilityCurrent15minEntry 5 }
endOfFrTrmt1FacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 186 }
frTrmt1FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrTrmt1FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 187 }
frTrmt1FacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX FrTrmt1FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { frTrmt1FacilityCurrent1dayTable 1 }
FrTrmt1FacilityCurrent1dayEntry ::= SEQUENCE
{ frTrmt1FacilityCurrent1dayGoodFramesx Counter64String,
frTrmt1FacilityCurrent1dayPauseFrames Counter64String,
frTrmt1FacilityCurrent1dayBytes Counter64String,
frTrmt1FacilityCurrent1dayCrcFramesEgress Counter64String,
frTrmt1FacilityCurrent1dayElapsedTime Integer32 }
frTrmt1FacilityCurrent1dayGoodFramesx OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { frTrmt1FacilityCurrent1dayEntry 1 }
frTrmt1FacilityCurrent1dayPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { frTrmt1FacilityCurrent1dayEntry 2 }
frTrmt1FacilityCurrent1dayBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { frTrmt1FacilityCurrent1dayEntry 3 }
frTrmt1FacilityCurrent1dayCrcFramesEgress OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress CRC Errored Frames"
::= { frTrmt1FacilityCurrent1dayEntry 4 }
frTrmt1FacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { frTrmt1FacilityCurrent1dayEntry 5 }
endOfFrTrmt1FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 188 }
frTrmt1FacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrTrmt1FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 189 }
frTrmt1FacilityHistorical15minEntry OBJECT-TYPE
SYNTAX FrTrmt1FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
frTrmt1FacilityHistorical15minNumber
}
::= { frTrmt1FacilityHistorical15minTable 1 }
FrTrmt1FacilityHistorical15minEntry ::= SEQUENCE
{ frTrmt1FacilityHistorical15minNumber Integer32,
frTrmt1FacilityHistorical15minGoodFramesx Counter64String,
frTrmt1FacilityHistorical15minPauseFrames Counter64String,
frTrmt1FacilityHistorical15minBytes Counter64String,
frTrmt1FacilityHistorical15minCrcFramesEgress Counter64String,
frTrmt1FacilityHistorical15minValidFlag TruthValue,
frTrmt1FacilityHistorical15minTimeStamp DateAndTime }
frTrmt1FacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { frTrmt1FacilityHistorical15minEntry 1 }
frTrmt1FacilityHistorical15minGoodFramesx OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { frTrmt1FacilityHistorical15minEntry 2 }
frTrmt1FacilityHistorical15minPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { frTrmt1FacilityHistorical15minEntry 3 }
frTrmt1FacilityHistorical15minBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { frTrmt1FacilityHistorical15minEntry 4 }
frTrmt1FacilityHistorical15minCrcFramesEgress OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress CRC Errored Frames"
::= { frTrmt1FacilityHistorical15minEntry 5 }
frTrmt1FacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { frTrmt1FacilityHistorical15minEntry 6 }
frTrmt1FacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { frTrmt1FacilityHistorical15minEntry 7 }
endOfFrTrmt1FacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 190 }
frTrmt1FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrTrmt1FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 191 }
frTrmt1FacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX FrTrmt1FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
frTrmt1FacilityHistorical1dayNumber
}
::= { frTrmt1FacilityHistorical1dayTable 1 }
FrTrmt1FacilityHistorical1dayEntry ::= SEQUENCE
{ frTrmt1FacilityHistorical1dayNumber Integer32,
frTrmt1FacilityHistorical1dayGoodFramesx Counter64String,
frTrmt1FacilityHistorical1dayPauseFrames Counter64String,
frTrmt1FacilityHistorical1dayBytes Counter64String,
frTrmt1FacilityHistorical1dayCrcFramesEgress Counter64String,
frTrmt1FacilityHistorical1dayValidFlag TruthValue,
frTrmt1FacilityHistorical1dayTimeStamp DateAndTime }
frTrmt1FacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { frTrmt1FacilityHistorical1dayEntry 1 }
frTrmt1FacilityHistorical1dayGoodFramesx OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { frTrmt1FacilityHistorical1dayEntry 2 }
frTrmt1FacilityHistorical1dayPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { frTrmt1FacilityHistorical1dayEntry 3 }
frTrmt1FacilityHistorical1dayBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { frTrmt1FacilityHistorical1dayEntry 4 }
frTrmt1FacilityHistorical1dayCrcFramesEgress OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress CRC Errored Frames"
::= { frTrmt1FacilityHistorical1dayEntry 5 }
frTrmt1FacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { frTrmt1FacilityHistorical1dayEntry 6 }
frTrmt1FacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { frTrmt1FacilityHistorical1dayEntry 7 }
endOfFrTrmt1FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 192 }
sarLinkTrmtFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF SarLinkTrmtFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 193 }
sarLinkTrmtFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX SarLinkTrmtFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { sarLinkTrmtFacilityCurrent15minTable 1 }
SarLinkTrmtFacilityCurrent15minEntry ::= SEQUENCE
{ sarLinkTrmtFacilityCurrent15minES Unsigned32,
sarLinkTrmtFacilityCurrent15minSES Counter64String,
sarLinkTrmtFacilityCurrent15minElapsedTime Integer32 }
sarLinkTrmtFacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Transmit ES"
::= { sarLinkTrmtFacilityCurrent15minEntry 1 }
sarLinkTrmtFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Transmit SES"
::= { sarLinkTrmtFacilityCurrent15minEntry 2 }
sarLinkTrmtFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { sarLinkTrmtFacilityCurrent15minEntry 3 }
endOfSarLinkTrmt1FacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 194 }
sarLinkTrmtFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF SarLinkTrmtFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 195 }
sarLinkTrmtFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX SarLinkTrmtFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { sarLinkTrmtFacilityCurrent1dayTable 1 }
SarLinkTrmtFacilityCurrent1dayEntry ::= SEQUENCE
{ sarLinkTrmtFacilityCurrent1dayES Unsigned32,
sarLinkTrmtFacilityCurrent1daySES Counter64String,
sarLinkTrmtFacilityCurrent1dayElapsedTime Integer32 }
sarLinkTrmtFacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Transmit ES"
::= { sarLinkTrmtFacilityCurrent1dayEntry 1 }
sarLinkTrmtFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Transmit SES"
::= { sarLinkTrmtFacilityCurrent1dayEntry 2 }
sarLinkTrmtFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { sarLinkTrmtFacilityCurrent1dayEntry 3 }
endOfSarLinkTrmt1FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 196 }
sarLinkTrmtFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF SarLinkTrmtFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 197 }
sarLinkTrmtFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX SarLinkTrmtFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
sarLinkTrmtFacilityHistorical15minNumber
}
::= { sarLinkTrmtFacilityHistorical15minTable 1 }
SarLinkTrmtFacilityHistorical15minEntry ::= SEQUENCE
{ sarLinkTrmtFacilityHistorical15minNumber Integer32,
sarLinkTrmtFacilityHistorical15minES Unsigned32,
sarLinkTrmtFacilityHistorical15minSES Counter64String,
sarLinkTrmtFacilityHistorical15minValidFlag TruthValue,
sarLinkTrmtFacilityHistorical15minTimeStamp DateAndTime }
sarLinkTrmtFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { sarLinkTrmtFacilityHistorical15minEntry 1 }
sarLinkTrmtFacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Transmit ES"
::= { sarLinkTrmtFacilityHistorical15minEntry 2 }
sarLinkTrmtFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Transmit SES"
::= { sarLinkTrmtFacilityHistorical15minEntry 3 }
sarLinkTrmtFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { sarLinkTrmtFacilityHistorical15minEntry 4 }
sarLinkTrmtFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { sarLinkTrmtFacilityHistorical15minEntry 5 }
endOfSarLinkTrmt1FacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 198 }
sarLinkTrmtFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF SarLinkTrmtFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 199 }
sarLinkTrmtFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX SarLinkTrmtFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
sarLinkTrmtFacilityHistorical1dayNumber
}
::= { sarLinkTrmtFacilityHistorical1dayTable 1 }
SarLinkTrmtFacilityHistorical1dayEntry ::= SEQUENCE
{ sarLinkTrmtFacilityHistorical1dayNumber Integer32,
sarLinkTrmtFacilityHistorical1dayES Unsigned32,
sarLinkTrmtFacilityHistorical1daySES Counter64String,
sarLinkTrmtFacilityHistorical1dayValidFlag TruthValue,
sarLinkTrmtFacilityHistorical1dayTimeStamp DateAndTime }
sarLinkTrmtFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { sarLinkTrmtFacilityHistorical1dayEntry 1 }
sarLinkTrmtFacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Transmit ES"
::= { sarLinkTrmtFacilityHistorical1dayEntry 2 }
sarLinkTrmtFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Transmit SES"
::= { sarLinkTrmtFacilityHistorical1dayEntry 3 }
sarLinkTrmtFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { sarLinkTrmtFacilityHistorical1dayEntry 4 }
sarLinkTrmtFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { sarLinkTrmtFacilityHistorical1dayEntry 5 }
endOfSarLinkTrmt1FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 200 }
sarLinkRcvFacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF SarLinkRcvFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 201 }
sarLinkRcvFacilityCurrent15minEntry OBJECT-TYPE
SYNTAX SarLinkRcvFacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { sarLinkRcvFacilityCurrent15minTable 1 }
SarLinkRcvFacilityCurrent15minEntry ::= SEQUENCE
{ sarLinkRcvFacilityCurrent15minES Unsigned32,
sarLinkRcvFacilityCurrent15minSES Unsigned32,
sarLinkRcvFacilityCurrent15minElapsedTime Integer32 }
sarLinkRcvFacilityCurrent15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Receive ES"
::= { sarLinkRcvFacilityCurrent15minEntry 1 }
sarLinkRcvFacilityCurrent15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Recive SES"
::= { sarLinkRcvFacilityCurrent15minEntry 2 }
sarLinkRcvFacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { sarLinkRcvFacilityCurrent15minEntry 3 }
endOfSarLinkRcvFacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 202 }
sarLinkRcvFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF SarLinkRcvFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 203 }
sarLinkRcvFacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX SarLinkRcvFacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { sarLinkRcvFacilityCurrent1dayTable 1 }
SarLinkRcvFacilityCurrent1dayEntry ::= SEQUENCE
{ sarLinkRcvFacilityCurrent1dayES Unsigned32,
sarLinkRcvFacilityCurrent1daySES Unsigned32,
sarLinkRcvFacilityCurrent1dayElapsedTime Integer32 }
sarLinkRcvFacilityCurrent1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Receive ES"
::= { sarLinkRcvFacilityCurrent1dayEntry 1 }
sarLinkRcvFacilityCurrent1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Recive SES"
::= { sarLinkRcvFacilityCurrent1dayEntry 2 }
sarLinkRcvFacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { sarLinkRcvFacilityCurrent1dayEntry 3 }
endOfSarLinkRcvFacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 204 }
sarLinkRcvFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF SarLinkRcvFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 205 }
sarLinkRcvFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX SarLinkRcvFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
sarLinkRcvFacilityHistorical15minNumber
}
::= { sarLinkRcvFacilityHistorical15minTable 1 }
SarLinkRcvFacilityHistorical15minEntry ::= SEQUENCE
{ sarLinkRcvFacilityHistorical15minNumber Integer32,
sarLinkRcvFacilityHistorical15minES Unsigned32,
sarLinkRcvFacilityHistorical15minSES Unsigned32,
sarLinkRcvFacilityHistorical15minValidFlag TruthValue,
sarLinkRcvFacilityHistorical15minTimeStamp DateAndTime }
sarLinkRcvFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { sarLinkRcvFacilityHistorical15minEntry 1 }
sarLinkRcvFacilityHistorical15minES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Receive ES"
::= { sarLinkRcvFacilityHistorical15minEntry 2 }
sarLinkRcvFacilityHistorical15minSES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Recive SES"
::= { sarLinkRcvFacilityHistorical15minEntry 3 }
sarLinkRcvFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { sarLinkRcvFacilityHistorical15minEntry 4 }
sarLinkRcvFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { sarLinkRcvFacilityHistorical15minEntry 5 }
endOfSarLinkRcvFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 206 }
sarLinkRcvFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF SarLinkRcvFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 207 }
sarLinkRcvFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX SarLinkRcvFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
sarLinkRcvFacilityHistorical1dayNumber
}
::= { sarLinkRcvFacilityHistorical1dayTable 1 }
SarLinkRcvFacilityHistorical1dayEntry ::= SEQUENCE
{ sarLinkRcvFacilityHistorical1dayNumber Integer32,
sarLinkRcvFacilityHistorical1dayES Unsigned32,
sarLinkRcvFacilityHistorical1daySES Unsigned32,
sarLinkRcvFacilityHistorical1dayValidFlag TruthValue,
sarLinkRcvFacilityHistorical1dayTimeStamp DateAndTime }
sarLinkRcvFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { sarLinkRcvFacilityHistorical1dayEntry 1 }
sarLinkRcvFacilityHistorical1dayES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Receive ES"
::= { sarLinkRcvFacilityHistorical1dayEntry 2 }
sarLinkRcvFacilityHistorical1daySES OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SAR Link Recive SES"
::= { sarLinkRcvFacilityHistorical1dayEntry 3 }
sarLinkRcvFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { sarLinkRcvFacilityHistorical1dayEntry 4 }
sarLinkRcvFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { sarLinkRcvFacilityHistorical1dayEntry 5 }
endOfSarLinkRcvFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 208 }
frTrmt2FacilityCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrTrmt2FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 209 }
frTrmt2FacilityCurrent15minEntry OBJECT-TYPE
SYNTAX FrTrmt2FacilityCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { frTrmt2FacilityCurrent15minTable 1 }
FrTrmt2FacilityCurrent15minEntry ::= SEQUENCE
{ frTrmt2FacilityCurrent15minGoodFramesx Counter64String,
frTrmt2FacilityCurrent15minPauseFrames Counter64String,
frTrmt2FacilityCurrent15minBytes Counter64String,
frTrmt2FacilityCurrent15minCrcFramesEgress Counter64String,
frTrmt2FacilityCurrent15minDiscardedFrames Counter64String,
frTrmt2FacilityCurrent15minElapsedTime Integer32 }
frTrmt2FacilityCurrent15minGoodFramesx OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { frTrmt2FacilityCurrent15minEntry 1 }
frTrmt2FacilityCurrent15minPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { frTrmt2FacilityCurrent15minEntry 2 }
frTrmt2FacilityCurrent15minBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { frTrmt2FacilityCurrent15minEntry 3 }
frTrmt2FacilityCurrent15minCrcFramesEgress OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress CRC Errored Frames"
::= { frTrmt2FacilityCurrent15minEntry 4 }
frTrmt2FacilityCurrent15minDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit Frames Discarded"
::= { frTrmt2FacilityCurrent15minEntry 5 }
frTrmt2FacilityCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { frTrmt2FacilityCurrent15minEntry 6 }
endOfFrTrmt2FacilityCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 210 }
frTrmt2FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrTrmt2FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 211 }
frTrmt2FacilityCurrent1dayEntry OBJECT-TYPE
SYNTAX FrTrmt2FacilityCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { frTrmt2FacilityCurrent1dayTable 1 }
FrTrmt2FacilityCurrent1dayEntry ::= SEQUENCE
{ frTrmt2FacilityCurrent1dayGoodFramesx Counter64String,
frTrmt2FacilityCurrent1dayPauseFrames Counter64String,
frTrmt2FacilityCurrent1dayBytes Counter64String,
frTrmt2FacilityCurrent1dayCrcFramesEgress Counter64String,
frTrmt2FacilityCurrent1dayDiscardedFrames Counter64String,
frTrmt2FacilityCurrent1dayElapsedTime Integer32 }
frTrmt2FacilityCurrent1dayGoodFramesx OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { frTrmt2FacilityCurrent1dayEntry 1 }
frTrmt2FacilityCurrent1dayPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { frTrmt2FacilityCurrent1dayEntry 2 }
frTrmt2FacilityCurrent1dayBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { frTrmt2FacilityCurrent1dayEntry 3 }
frTrmt2FacilityCurrent1dayCrcFramesEgress OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress CRC Errored Frames"
::= { frTrmt2FacilityCurrent1dayEntry 4 }
frTrmt2FacilityCurrent1dayDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit Frames Discarded"
::= { frTrmt2FacilityCurrent1dayEntry 5 }
frTrmt2FacilityCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { frTrmt2FacilityCurrent1dayEntry 6 }
endOfFrTrmt2FacilityCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 212 }
frTrmt2FacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrTrmt2FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 213 }
frTrmt2FacilityHistorical15minEntry OBJECT-TYPE
SYNTAX FrTrmt2FacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
frTrmt2FacilityHistorical15minNumber
}
::= { frTrmt2FacilityHistorical15minTable 1 }
FrTrmt2FacilityHistorical15minEntry ::= SEQUENCE
{ frTrmt2FacilityHistorical15minNumber Integer32,
frTrmt2FacilityHistorical15minGoodFramesx Counter64String,
frTrmt2FacilityHistorical15minPauseFrames Counter64String,
frTrmt2FacilityHistorical15minBytes Counter64String,
frTrmt2FacilityHistorical15minCrcFramesEgress Counter64String,
frTrmt2FacilityHistorical15minDiscardedFrames Counter64String,
frTrmt2FacilityHistorical15minValidFlag TruthValue,
frTrmt2FacilityHistorical15minTimeStamp DateAndTime }
frTrmt2FacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { frTrmt2FacilityHistorical15minEntry 1 }
frTrmt2FacilityHistorical15minGoodFramesx OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { frTrmt2FacilityHistorical15minEntry 2 }
frTrmt2FacilityHistorical15minPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { frTrmt2FacilityHistorical15minEntry 3 }
frTrmt2FacilityHistorical15minBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { frTrmt2FacilityHistorical15minEntry 4 }
frTrmt2FacilityHistorical15minCrcFramesEgress OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress CRC Errored Frames"
::= { frTrmt2FacilityHistorical15minEntry 5 }
frTrmt2FacilityHistorical15minDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit Frames Discarded"
::= { frTrmt2FacilityHistorical15minEntry 6 }
frTrmt2FacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { frTrmt2FacilityHistorical15minEntry 7 }
frTrmt2FacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { frTrmt2FacilityHistorical15minEntry 8 }
endOfFrTrmt2FacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 214 }
frTrmt2FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrTrmt2FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityDataRecord 215 }
frTrmt2FacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX FrTrmt2FacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName,
frTrmt2FacilityHistorical1dayNumber
}
::= { frTrmt2FacilityHistorical1dayTable 1 }
FrTrmt2FacilityHistorical1dayEntry ::= SEQUENCE
{ frTrmt2FacilityHistorical1dayNumber Integer32,
frTrmt2FacilityHistorical1dayGoodFramesx Counter64String,
frTrmt2FacilityHistorical1dayPauseFrames Counter64String,
frTrmt2FacilityHistorical1dayBytes Counter64String,
frTrmt2FacilityHistorical1dayCrcFramesEgress Counter64String,
frTrmt2FacilityHistorical1dayDiscardedFrames Counter64String,
frTrmt2FacilityHistorical1dayValidFlag TruthValue,
frTrmt2FacilityHistorical1dayTimeStamp DateAndTime }
frTrmt2FacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { frTrmt2FacilityHistorical1dayEntry 1 }
frTrmt2FacilityHistorical1dayGoodFramesx OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames Transmitted"
::= { frTrmt2FacilityHistorical1dayEntry 2 }
frTrmt2FacilityHistorical1dayPauseFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pause Frames Transmitted"
::= { frTrmt2FacilityHistorical1dayEntry 3 }
frTrmt2FacilityHistorical1dayBytes OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes Transmitted"
::= { frTrmt2FacilityHistorical1dayEntry 4 }
frTrmt2FacilityHistorical1dayCrcFramesEgress OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress CRC Errored Frames"
::= { frTrmt2FacilityHistorical1dayEntry 5 }
frTrmt2FacilityHistorical1dayDiscardedFrames OBJECT-TYPE
SYNTAX Counter64String
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit Frames Discarded"
::= { frTrmt2FacilityHistorical1dayEntry 6 }
frTrmt2FacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { frTrmt2FacilityHistorical1dayEntry 7 }
frTrmt2FacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { frTrmt2FacilityHistorical1dayEntry 8 }
endOfFrTrmt2FacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 216 }
endOfPmFacilityDataRecord OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityDataRecord 10000 }
facilityPhysInstValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF FacilityPhysInstValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysValue 1 }
facilityPhysInstValueEntry OBJECT-TYPE
SYNTAX FacilityPhysInstValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { facilityPhysInstValueTable 1 }
FacilityPhysInstValueEntry ::= SEQUENCE
{ facilityPhysInstValueOutputPower Integer32,
facilityPhysInstValueInputPower Integer32,
facilityPhysInstValueLaserTemp Integer32,
facilityPhysInstValueLaserBiasCurrentLevel Unsigned32,
facilityPhysInstValuePrbsMaxBER Counter64String,
facilityPhysInstValueAttenuationOfVoa Unsigned32,
facilityPhysInstValueLocalOscTemp Integer32,
facilityPhysInstValuePrbsElapsedTime Unsigned32,
facilityPhysInstValueLocalOscBiasLevel Unsigned32,
facilityPhysInstValuePrbsErrorFreeTime Unsigned32,
facilityPhysInstValuePrbsAvgBER Counter64String,
facilityPhysInstValueLogicalLanesSkew Integer32,
facilityPhysInstValueRoundTripDelay Unsigned32,
facilityPhysInstValueSignalToNoiseRatio Integer32,
facilityPhysInstValueCarrierFreqOffset Integer32,
facilityPhysInstValueLatency Unsigned32,
facilityPhysInstValueDifferentialGroupDelay Integer32,
facilityPhysInstValueLaserBiasCurrentNormalized Unsigned32,
facilityPhysInstValueChromaticDispersion Integer32,
facilityPhysInstValueChromaticDispComp Integer32 }
facilityPhysInstValueOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Instantaneous Optical Power Transmitted (Output)"
::= { facilityPhysInstValueEntry 1 }
facilityPhysInstValueInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Optical Input Power Received"
::= { facilityPhysInstValueEntry 2 }
facilityPhysInstValueLaserTemp OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Temperature"
::= { facilityPhysInstValueEntry 3 }
facilityPhysInstValueLaserBiasCurrentLevel OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Level on demand"
::= { facilityPhysInstValueEntry 4 }
facilityPhysInstValuePrbsMaxBER OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-15"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum measured BER for the PRBS Test signal during monitored time"
::= { facilityPhysInstValueEntry 5 }
facilityPhysInstValueAttenuationOfVoa OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Variable Attenuator attenuation in dB"
::= { facilityPhysInstValueEntry 6 }
facilityPhysInstValueLocalOscTemp OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Instantaneous Rx Laser Temperature (used for Local Oscillator)"
::= { facilityPhysInstValueEntry 7 }
facilityPhysInstValuePrbsElapsedTime OBJECT-TYPE
SYNTAX Unsigned32
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time elapsed since PRBS test monitoring started - reset"
::= { facilityPhysInstValueEntry 8 }
facilityPhysInstValueLocalOscBiasLevel OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Laser Bias Current Level used for Local Oscillator"
::= { facilityPhysInstValueEntry 9 }
facilityPhysInstValuePrbsErrorFreeTime OBJECT-TYPE
SYNTAX Unsigned32
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time elapsed since last PRBS Error detected"
::= { facilityPhysInstValueEntry 10 }
facilityPhysInstValuePrbsAvgBER OBJECT-TYPE
SYNTAX Counter64String
UNITS "1.0E-15"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average BER for the PRBS test signal during the monitored time"
::= { facilityPhysInstValueEntry 11 }
facilityPhysInstValueLogicalLanesSkew OBJECT-TYPE
SYNTAX Integer32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Skew between logical lanes farthest apart"
::= { facilityPhysInstValueEntry 12 }
facilityPhysInstValueRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32 (0..30000000 | 4294967295)
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay"
::= { facilityPhysInstValueEntry 13 }
facilityPhysInstValueSignalToNoiseRatio OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal-to-Noise Ratio measured by the module"
::= { facilityPhysInstValueEntry 14 }
facilityPhysInstValueCarrierFreqOffset OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 GHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier Frequency Offset"
::= { facilityPhysInstValueEntry 15 }
facilityPhysInstValueLatency OBJECT-TYPE
SYNTAX Unsigned32 (0..300000 | 4294967295)
UNITS "0.1 us"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay"
::= { facilityPhysInstValueEntry 16 }
facilityPhysInstValueDifferentialGroupDelay OBJECT-TYPE
SYNTAX Integer32
UNITS "ps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential Group Delay measured and compensated by the module"
::= { facilityPhysInstValueEntry 17 }
facilityPhysInstValueLaserBiasCurrentNormalized OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Instantaneous Laser Bias Current Normalized"
::= { facilityPhysInstValueEntry 18 }
facilityPhysInstValueChromaticDispersion OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation"
::= { facilityPhysInstValueEntry 19 }
facilityPhysInstValueChromaticDispComp OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation"
::= { facilityPhysInstValueEntry 20 }
endOfFacilityPhysInstValueTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysValue 2 }
endOfPmFacilityPhysValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysValue 10000 }
facilityPhysThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF FacilityPhysThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysThreshold 1 }
facilityPhysThresholdEntry OBJECT-TYPE
SYNTAX FacilityPhysThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityFacilityShelfNo,
entityFacilitySlotNo,
entityFacilityPortNo,
entityFacilityExtNo,
entityFacilityClassName
}
::= { facilityPhysThresholdTable 1 }
FacilityPhysThresholdEntry ::= SEQUENCE
{ facilityPhysThresholdOpticalInputPwrLow Integer32,
facilityPhysThresholdOpticalInputPwrHigh Integer32,
facilityPhysThresholdConfigOpticalOutputPwrLow Integer32,
facilityPhysThresholdConfigOpticalOutputPwrHigh Integer32,
facilityPhysThresholdOpticalOutputPwrHigh Integer32,
facilityPhysThresholdOpticalOutputPwrLow Integer32,
facilityPhysThresholdLaserTempHighThres Integer32,
facilityPhysThresholdLaserTempLowThres Integer32,
facilityPhysThresholdRoundTripDelayLowThres Integer32,
facilityPhysThresholdRoundTripDelayHighThres Integer32,
facilityPhysThresholdLatencyLowThres Integer32,
facilityPhysThresholdLatencyHighThres Integer32,
facilityPhysThresholdChromaticDispersionHigh Integer32,
facilityPhysThresholdChromaticDispersionLow Integer32,
facilityPhysThresholdCarrierFreqOffsetLow Integer32,
facilityPhysThresholdCarrierFreqOffsetHigh Integer32,
facilityPhysThresholdDispersionCompensationLowThres Integer32,
facilityPhysThresholdDispersionCompensationHighThres Integer32,
facilityPhysThresholdDifferentialGroupDelayHigh Integer32,
facilityPhysThresholdLogicalLanesSkewHigh Integer32,
facilityPhysThresholdLaserBiasCurrentNormalized Unsigned32,
facilityPhysThresholdLocalOscTempLowThres Integer32,
facilityPhysThresholdLocalOscTempHighThres Integer32,
facilityPhysThresholdSignalToNoiseRatioLow Integer32 }
facilityPhysThresholdOpticalInputPwrLow OBJECT-TYPE
SYNTAX Integer32 (-450..260 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { facilityPhysThresholdEntry 1 }
facilityPhysThresholdOpticalInputPwrHigh OBJECT-TYPE
SYNTAX Integer32 (-450..260 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { facilityPhysThresholdEntry 2 }
facilityPhysThresholdConfigOpticalOutputPwrLow OBJECT-TYPE
SYNTAX Integer32 (-500..300 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configurable threshold of the Optical Power Transmitted (output)"
::= { facilityPhysThresholdEntry 3 }
facilityPhysThresholdConfigOpticalOutputPwrHigh OBJECT-TYPE
SYNTAX Integer32 (-500..300 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configurable high threshold of the Optical Power Transmitted (output)"
::= { facilityPhysThresholdEntry 4 }
facilityPhysThresholdOpticalOutputPwrHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High fixed threshold of the Optical Power Transmitted (output)"
::= { facilityPhysThresholdEntry 5 }
facilityPhysThresholdOpticalOutputPwrLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low fixed threshold of the Optical Power Transmitted (output)"
::= { facilityPhysThresholdEntry 6 }
facilityPhysThresholdLaserTempHighThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser temperature fixed high threshold."
::= { facilityPhysThresholdEntry 7 }
facilityPhysThresholdLaserTempLowThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser temperature fixed low threshold."
::= { facilityPhysThresholdEntry 8 }
facilityPhysThresholdRoundTripDelayLowThres OBJECT-TYPE
SYNTAX Integer32 (0..30000000 | -2147483648)
UNITS "ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configurable low threshold for round trip delay"
::= { facilityPhysThresholdEntry 9 }
facilityPhysThresholdRoundTripDelayHighThres OBJECT-TYPE
SYNTAX Integer32 (1..30000000 | -2147483648)
UNITS "ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configurable high threshold for round trip delay"
::= { facilityPhysThresholdEntry 10 }
facilityPhysThresholdLatencyLowThres OBJECT-TYPE
SYNTAX Integer32 (0..300000 | -2147483648)
UNITS "0.1 us"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configurable low threshold round trip delay"
::= { facilityPhysThresholdEntry 11 }
facilityPhysThresholdLatencyHighThres OBJECT-TYPE
SYNTAX Integer32 (1..300000 | -2147483648)
UNITS "0.1 us"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configurable high threshold for round trip delay"
::= { facilityPhysThresholdEntry 12 }
facilityPhysThresholdChromaticDispersionHigh OBJECT-TYPE
SYNTAX Integer32 (-100000..100000 | -2147483648)
UNITS "ps/nm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation High Threshold"
::= { facilityPhysThresholdEntry 13 }
facilityPhysThresholdChromaticDispersionLow OBJECT-TYPE
SYNTAX Integer32 (-100000..100000 | -2147483648)
UNITS "ps/nm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Low Threshold"
::= { facilityPhysThresholdEntry 14 }
facilityPhysThresholdCarrierFreqOffsetLow OBJECT-TYPE
SYNTAX Integer32 (-32000..32000 | -2147483648)
UNITS "0.001 GHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Carrier Frequency Offset Low TH"
::= { facilityPhysThresholdEntry 15 }
facilityPhysThresholdCarrierFreqOffsetHigh OBJECT-TYPE
SYNTAX Integer32 (-32000..32000 | -2147483648)
UNITS "0.001 GHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Carrier Frequency Offset High TH"
::= { facilityPhysThresholdEntry 16 }
facilityPhysThresholdDispersionCompensationLowThres OBJECT-TYPE
SYNTAX Integer32 (-50000..50000 | -2147483648)
UNITS "ps/nm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Low Threshold"
::= { facilityPhysThresholdEntry 17 }
facilityPhysThresholdDispersionCompensationHighThres OBJECT-TYPE
SYNTAX Integer32 (-50000..50000 | -2147483648)
UNITS "ps/nm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation High Threshold"
::= { facilityPhysThresholdEntry 18 }
facilityPhysThresholdDifferentialGroupDelayHigh OBJECT-TYPE
SYNTAX Integer32 (0..100 | -2147483648)
UNITS "ps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Differential Group Delay High TH"
::= { facilityPhysThresholdEntry 19 }
facilityPhysThresholdLogicalLanesSkewHigh OBJECT-TYPE
SYNTAX Integer32 (0..1000 | -2147483648)
UNITS "ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Skew between logical lanes farthest apart high threshold"
::= { facilityPhysThresholdEntry 20 }
facilityPhysThresholdLaserBiasCurrentNormalized OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized Fixed High Threshold."
::= { facilityPhysThresholdEntry 21 }
facilityPhysThresholdLocalOscTempLowThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Laser unsed for Local Oscillator Temperature Fixed Low Threshold"
::= { facilityPhysThresholdEntry 22 }
facilityPhysThresholdLocalOscTempHighThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Laser used for Local Oscillator Temperature Fixed High Threshold"
::= { facilityPhysThresholdEntry 23 }
facilityPhysThresholdSignalToNoiseRatioLow OBJECT-TYPE
SYNTAX Integer32 (80..160 | -2147483648)
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signal-to-Noise Ratio Low TH"
::= { facilityPhysThresholdEntry 24 }
endOfFacilityPhysThresholdTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysThreshold 2 }
endOfPmFacilityPhysThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysThreshold 10000 }
optFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 1 }
optFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX OptFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
optFacilityHistorical15minNumber
}
::= { optFacilityHistorical15minTable 1 }
OptFacilityHistorical15minEntry ::= SEQUENCE
{ optFacilityHistorical15minNumber Integer32,
optFacilityHistorical15minLow Integer32,
optFacilityHistorical15minMean Integer32,
optFacilityHistorical15minHigh Integer32,
optFacilityHistorical15minValidFlag TruthValue,
optFacilityHistorical15minTimeStamp DateAndTime }
optFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { optFacilityHistorical15minEntry 1 }
optFacilityHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optFacilityHistorical15minEntry 2 }
optFacilityHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optFacilityHistorical15minEntry 3 }
optFacilityHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optFacilityHistorical15minEntry 4 }
optFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { optFacilityHistorical15minEntry 5 }
optFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { optFacilityHistorical15minEntry 6 }
endOfOptFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 2 }
optFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 3 }
optFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX OptFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
optFacilityHistorical1dayNumber
}
::= { optFacilityHistorical1dayTable 1 }
OptFacilityHistorical1dayEntry ::= SEQUENCE
{ optFacilityHistorical1dayNumber Integer32,
optFacilityHistorical1dayLow Integer32,
optFacilityHistorical1dayMean Integer32,
optFacilityHistorical1dayHigh Integer32,
optFacilityHistorical1dayValidFlag TruthValue,
optFacilityHistorical1dayTimeStamp DateAndTime }
optFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { optFacilityHistorical1dayEntry 1 }
optFacilityHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optFacilityHistorical1dayEntry 2 }
optFacilityHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optFacilityHistorical1dayEntry 3 }
optFacilityHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optFacilityHistorical1dayEntry 4 }
optFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { optFacilityHistorical1dayEntry 5 }
optFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { optFacilityHistorical1dayEntry 6 }
endOfOptFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 4 }
optFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 5 }
optFacilityHistorical1weekEntry OBJECT-TYPE
SYNTAX OptFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
optFacilityHistorical1weekNumber
}
::= { optFacilityHistorical1weekTable 1 }
OptFacilityHistorical1weekEntry ::= SEQUENCE
{ optFacilityHistorical1weekNumber Integer32,
optFacilityHistorical1weekLow Integer32,
optFacilityHistorical1weekMean Integer32,
optFacilityHistorical1weekHigh Integer32,
optFacilityHistorical1weekValidFlag TruthValue,
optFacilityHistorical1weekTimeStamp DateAndTime }
optFacilityHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { optFacilityHistorical1weekEntry 1 }
optFacilityHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optFacilityHistorical1weekEntry 2 }
optFacilityHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optFacilityHistorical1weekEntry 3 }
optFacilityHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optFacilityHistorical1weekEntry 4 }
optFacilityHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { optFacilityHistorical1weekEntry 5 }
optFacilityHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { optFacilityHistorical1weekEntry 6 }
endOfOptFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 6 }
oprFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OprFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 7 }
oprFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX OprFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
oprFacilityHistorical15minNumber
}
::= { oprFacilityHistorical15minTable 1 }
OprFacilityHistorical15minEntry ::= SEQUENCE
{ oprFacilityHistorical15minNumber Integer32,
oprFacilityHistorical15minLow Integer32,
oprFacilityHistorical15minMean Integer32,
oprFacilityHistorical15minHigh Integer32,
oprFacilityHistorical15minValidFlag TruthValue,
oprFacilityHistorical15minTimeStamp DateAndTime }
oprFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { oprFacilityHistorical15minEntry 1 }
oprFacilityHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprFacilityHistorical15minEntry 2 }
oprFacilityHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprFacilityHistorical15minEntry 3 }
oprFacilityHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprFacilityHistorical15minEntry 4 }
oprFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oprFacilityHistorical15minEntry 5 }
oprFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oprFacilityHistorical15minEntry 6 }
endOfOprFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 8 }
oprFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OprFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 9 }
oprFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX OprFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
oprFacilityHistorical1dayNumber
}
::= { oprFacilityHistorical1dayTable 1 }
OprFacilityHistorical1dayEntry ::= SEQUENCE
{ oprFacilityHistorical1dayNumber Integer32,
oprFacilityHistorical1dayLow Integer32,
oprFacilityHistorical1dayMean Integer32,
oprFacilityHistorical1dayHigh Integer32,
oprFacilityHistorical1dayValidFlag TruthValue,
oprFacilityHistorical1dayTimeStamp DateAndTime }
oprFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { oprFacilityHistorical1dayEntry 1 }
oprFacilityHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprFacilityHistorical1dayEntry 2 }
oprFacilityHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprFacilityHistorical1dayEntry 3 }
oprFacilityHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprFacilityHistorical1dayEntry 4 }
oprFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oprFacilityHistorical1dayEntry 5 }
oprFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oprFacilityHistorical1dayEntry 6 }
endOfOprFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 10 }
oprFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF OprFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 11 }
oprFacilityHistorical1weekEntry OBJECT-TYPE
SYNTAX OprFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
oprFacilityHistorical1weekNumber
}
::= { oprFacilityHistorical1weekTable 1 }
OprFacilityHistorical1weekEntry ::= SEQUENCE
{ oprFacilityHistorical1weekNumber Integer32,
oprFacilityHistorical1weekLow Integer32,
oprFacilityHistorical1weekMean Integer32,
oprFacilityHistorical1weekHigh Integer32,
oprFacilityHistorical1weekValidFlag TruthValue,
oprFacilityHistorical1weekTimeStamp DateAndTime }
oprFacilityHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { oprFacilityHistorical1weekEntry 1 }
oprFacilityHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprFacilityHistorical1weekEntry 2 }
oprFacilityHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprFacilityHistorical1weekEntry 3 }
oprFacilityHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprFacilityHistorical1weekEntry 4 }
oprFacilityHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oprFacilityHistorical1weekEntry 5 }
oprFacilityHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oprFacilityHistorical1weekEntry 6 }
endOfOprFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 12 }
lbcnFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbcnFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 13 }
lbcnFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX LbcnFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
lbcnFacilityHistorical15minNumber
}
::= { lbcnFacilityHistorical15minTable 1 }
LbcnFacilityHistorical15minEntry ::= SEQUENCE
{ lbcnFacilityHistorical15minNumber Integer32,
lbcnFacilityHistorical15minLow Unsigned32,
lbcnFacilityHistorical15minMean Unsigned32,
lbcnFacilityHistorical15minHigh Unsigned32,
lbcnFacilityHistorical15minValidFlag TruthValue,
lbcnFacilityHistorical15minTimeStamp DateAndTime }
lbcnFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { lbcnFacilityHistorical15minEntry 1 }
lbcnFacilityHistorical15minLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnFacilityHistorical15minEntry 2 }
lbcnFacilityHistorical15minMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnFacilityHistorical15minEntry 3 }
lbcnFacilityHistorical15minHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnFacilityHistorical15minEntry 4 }
lbcnFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { lbcnFacilityHistorical15minEntry 5 }
lbcnFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { lbcnFacilityHistorical15minEntry 6 }
endOfLbcnFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 14 }
lbcnFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbcnFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 15 }
lbcnFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX LbcnFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
lbcnFacilityHistorical1dayNumber
}
::= { lbcnFacilityHistorical1dayTable 1 }
LbcnFacilityHistorical1dayEntry ::= SEQUENCE
{ lbcnFacilityHistorical1dayNumber Integer32,
lbcnFacilityHistorical1dayLow Unsigned32,
lbcnFacilityHistorical1dayMean Unsigned32,
lbcnFacilityHistorical1dayHigh Unsigned32,
lbcnFacilityHistorical1dayValidFlag TruthValue,
lbcnFacilityHistorical1dayTimeStamp DateAndTime }
lbcnFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { lbcnFacilityHistorical1dayEntry 1 }
lbcnFacilityHistorical1dayLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnFacilityHistorical1dayEntry 2 }
lbcnFacilityHistorical1dayMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnFacilityHistorical1dayEntry 3 }
lbcnFacilityHistorical1dayHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnFacilityHistorical1dayEntry 4 }
lbcnFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { lbcnFacilityHistorical1dayEntry 5 }
lbcnFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { lbcnFacilityHistorical1dayEntry 6 }
endOfLbcnFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 16 }
lbcnFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbcnFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 17 }
lbcnFacilityHistorical1weekEntry OBJECT-TYPE
SYNTAX LbcnFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
lbcnFacilityHistorical1weekNumber
}
::= { lbcnFacilityHistorical1weekTable 1 }
LbcnFacilityHistorical1weekEntry ::= SEQUENCE
{ lbcnFacilityHistorical1weekNumber Integer32,
lbcnFacilityHistorical1weekLow Unsigned32,
lbcnFacilityHistorical1weekMean Unsigned32,
lbcnFacilityHistorical1weekHigh Unsigned32,
lbcnFacilityHistorical1weekValidFlag TruthValue,
lbcnFacilityHistorical1weekTimeStamp DateAndTime }
lbcnFacilityHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { lbcnFacilityHistorical1weekEntry 1 }
lbcnFacilityHistorical1weekLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnFacilityHistorical1weekEntry 2 }
lbcnFacilityHistorical1weekMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnFacilityHistorical1weekEntry 3 }
lbcnFacilityHistorical1weekHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Normalized"
::= { lbcnFacilityHistorical1weekEntry 4 }
lbcnFacilityHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { lbcnFacilityHistorical1weekEntry 5 }
lbcnFacilityHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { lbcnFacilityHistorical1weekEntry 6 }
endOfLbcnFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 18 }
rndTrpDlyFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF RndTrpDlyFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 19 }
rndTrpDlyFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX RndTrpDlyFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
rndTrpDlyFacilityHistorical15minNumber
}
::= { rndTrpDlyFacilityHistorical15minTable 1 }
RndTrpDlyFacilityHistorical15minEntry ::= SEQUENCE
{ rndTrpDlyFacilityHistorical15minNumber Integer32,
rndTrpDlyFacilityHistorical15minLow Unsigned32,
rndTrpDlyFacilityHistorical15minMean Unsigned32,
rndTrpDlyFacilityHistorical15minHigh Unsigned32,
rndTrpDlyFacilityHistorical15minValidFlag TruthValue,
rndTrpDlyFacilityHistorical15minTimeStamp DateAndTime }
rndTrpDlyFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { rndTrpDlyFacilityHistorical15minEntry 1 }
rndTrpDlyFacilityHistorical15minLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay low"
::= { rndTrpDlyFacilityHistorical15minEntry 2 }
rndTrpDlyFacilityHistorical15minMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay mean"
::= { rndTrpDlyFacilityHistorical15minEntry 3 }
rndTrpDlyFacilityHistorical15minHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay high"
::= { rndTrpDlyFacilityHistorical15minEntry 4 }
rndTrpDlyFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { rndTrpDlyFacilityHistorical15minEntry 5 }
rndTrpDlyFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { rndTrpDlyFacilityHistorical15minEntry 6 }
endOfRndTrpDlyFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 20 }
rndTrpDlyFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF RndTrpDlyFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 21 }
rndTrpDlyFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX RndTrpDlyFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
rndTrpDlyFacilityHistorical1dayNumber
}
::= { rndTrpDlyFacilityHistorical1dayTable 1 }
RndTrpDlyFacilityHistorical1dayEntry ::= SEQUENCE
{ rndTrpDlyFacilityHistorical1dayNumber Integer32,
rndTrpDlyFacilityHistorical1dayLow Unsigned32,
rndTrpDlyFacilityHistorical1dayMean Unsigned32,
rndTrpDlyFacilityHistorical1dayHigh Unsigned32,
rndTrpDlyFacilityHistorical1dayValidFlag TruthValue,
rndTrpDlyFacilityHistorical1dayTimeStamp DateAndTime }
rndTrpDlyFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { rndTrpDlyFacilityHistorical1dayEntry 1 }
rndTrpDlyFacilityHistorical1dayLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay low"
::= { rndTrpDlyFacilityHistorical1dayEntry 2 }
rndTrpDlyFacilityHistorical1dayMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay mean"
::= { rndTrpDlyFacilityHistorical1dayEntry 3 }
rndTrpDlyFacilityHistorical1dayHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay high"
::= { rndTrpDlyFacilityHistorical1dayEntry 4 }
rndTrpDlyFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { rndTrpDlyFacilityHistorical1dayEntry 5 }
rndTrpDlyFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { rndTrpDlyFacilityHistorical1dayEntry 6 }
endOfRndTrpDlyFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 22 }
rndTrpDlyFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF RndTrpDlyFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 23 }
rndTrpDlyFacilityHistorical1weekEntry OBJECT-TYPE
SYNTAX RndTrpDlyFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
rndTrpDlyFacilityHistorical1weekNumber
}
::= { rndTrpDlyFacilityHistorical1weekTable 1 }
RndTrpDlyFacilityHistorical1weekEntry ::= SEQUENCE
{ rndTrpDlyFacilityHistorical1weekNumber Integer32,
rndTrpDlyFacilityHistorical1weekLow Unsigned32,
rndTrpDlyFacilityHistorical1weekMean Unsigned32,
rndTrpDlyFacilityHistorical1weekHigh Unsigned32,
rndTrpDlyFacilityHistorical1weekValidFlag TruthValue,
rndTrpDlyFacilityHistorical1weekTimeStamp DateAndTime }
rndTrpDlyFacilityHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { rndTrpDlyFacilityHistorical1weekEntry 1 }
rndTrpDlyFacilityHistorical1weekLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay low"
::= { rndTrpDlyFacilityHistorical1weekEntry 2 }
rndTrpDlyFacilityHistorical1weekMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay mean"
::= { rndTrpDlyFacilityHistorical1weekEntry 3 }
rndTrpDlyFacilityHistorical1weekHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay high"
::= { rndTrpDlyFacilityHistorical1weekEntry 4 }
rndTrpDlyFacilityHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { rndTrpDlyFacilityHistorical1weekEntry 5 }
rndTrpDlyFacilityHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { rndTrpDlyFacilityHistorical1weekEntry 6 }
endOfRndTrpDlyFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 24 }
skewFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF SkewFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 25 }
skewFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX SkewFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
skewFacilityHistorical15minNumber
}
::= { skewFacilityHistorical15minTable 1 }
SkewFacilityHistorical15minEntry ::= SEQUENCE
{ skewFacilityHistorical15minNumber Integer32,
skewFacilityHistorical15minLow Integer32,
skewFacilityHistorical15minMean Integer32,
skewFacilityHistorical15minHigh Integer32,
skewFacilityHistorical15minValidFlag TruthValue,
skewFacilityHistorical15minTimeStamp DateAndTime }
skewFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { skewFacilityHistorical15minEntry 1 }
skewFacilityHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Skew between logical lanes farthest apart low"
::= { skewFacilityHistorical15minEntry 2 }
skewFacilityHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Skew between logical lanes farthest apart mean"
::= { skewFacilityHistorical15minEntry 3 }
skewFacilityHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Skew between logical lanes farthest apart high"
::= { skewFacilityHistorical15minEntry 4 }
skewFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { skewFacilityHistorical15minEntry 5 }
skewFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { skewFacilityHistorical15minEntry 6 }
endOfSkewFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 26 }
skewFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF SkewFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 27 }
skewFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX SkewFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
skewFacilityHistorical1dayNumber
}
::= { skewFacilityHistorical1dayTable 1 }
SkewFacilityHistorical1dayEntry ::= SEQUENCE
{ skewFacilityHistorical1dayNumber Integer32,
skewFacilityHistorical1dayLow Integer32,
skewFacilityHistorical1dayMean Integer32,
skewFacilityHistorical1dayHigh Integer32,
skewFacilityHistorical1dayValidFlag TruthValue,
skewFacilityHistorical1dayTimeStamp DateAndTime }
skewFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { skewFacilityHistorical1dayEntry 1 }
skewFacilityHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Skew between logical lanes farthest apart low"
::= { skewFacilityHistorical1dayEntry 2 }
skewFacilityHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Skew between logical lanes farthest apart mean"
::= { skewFacilityHistorical1dayEntry 3 }
skewFacilityHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Skew between logical lanes farthest apart high"
::= { skewFacilityHistorical1dayEntry 4 }
skewFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { skewFacilityHistorical1dayEntry 5 }
skewFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { skewFacilityHistorical1dayEntry 6 }
endOfSkewFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 28 }
skewFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF SkewFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 29 }
skewFacilityHistorical1weekEntry OBJECT-TYPE
SYNTAX SkewFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
skewFacilityHistorical1weekNumber
}
::= { skewFacilityHistorical1weekTable 1 }
SkewFacilityHistorical1weekEntry ::= SEQUENCE
{ skewFacilityHistorical1weekNumber Integer32,
skewFacilityHistorical1weekLow Integer32,
skewFacilityHistorical1weekMean Integer32,
skewFacilityHistorical1weekHigh Integer32,
skewFacilityHistorical1weekValidFlag TruthValue,
skewFacilityHistorical1weekTimeStamp DateAndTime }
skewFacilityHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { skewFacilityHistorical1weekEntry 1 }
skewFacilityHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Skew between logical lanes farthest apart low"
::= { skewFacilityHistorical1weekEntry 2 }
skewFacilityHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Skew between logical lanes farthest apart mean"
::= { skewFacilityHistorical1weekEntry 3 }
skewFacilityHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Skew between logical lanes farthest apart high"
::= { skewFacilityHistorical1weekEntry 4 }
skewFacilityHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { skewFacilityHistorical1weekEntry 5 }
skewFacilityHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { skewFacilityHistorical1weekEntry 6 }
endOfSkewFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 30 }
snrFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnrFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 31 }
snrFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX SnrFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
snrFacilityHistorical15minNumber
}
::= { snrFacilityHistorical15minTable 1 }
SnrFacilityHistorical15minEntry ::= SEQUENCE
{ snrFacilityHistorical15minNumber Integer32,
snrFacilityHistorical15minLow Integer32,
snrFacilityHistorical15minMean Integer32,
snrFacilityHistorical15minHigh Integer32,
snrFacilityHistorical15minValidFlag TruthValue,
snrFacilityHistorical15minTimeStamp DateAndTime }
snrFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { snrFacilityHistorical15minEntry 1 }
snrFacilityHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal-to-Noise Ratio Low"
::= { snrFacilityHistorical15minEntry 2 }
snrFacilityHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal-to-Noise Ratio Mean"
::= { snrFacilityHistorical15minEntry 3 }
snrFacilityHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal-to-Noise Ratio High"
::= { snrFacilityHistorical15minEntry 4 }
snrFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { snrFacilityHistorical15minEntry 5 }
snrFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { snrFacilityHistorical15minEntry 6 }
endOfSnrFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 32 }
snrFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnrFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 33 }
snrFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX SnrFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
snrFacilityHistorical1dayNumber
}
::= { snrFacilityHistorical1dayTable 1 }
SnrFacilityHistorical1dayEntry ::= SEQUENCE
{ snrFacilityHistorical1dayNumber Integer32,
snrFacilityHistorical1dayLow Integer32,
snrFacilityHistorical1dayMean Integer32,
snrFacilityHistorical1dayHigh Integer32,
snrFacilityHistorical1dayValidFlag TruthValue,
snrFacilityHistorical1dayTimeStamp DateAndTime }
snrFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { snrFacilityHistorical1dayEntry 1 }
snrFacilityHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal-to-Noise Ratio Low"
::= { snrFacilityHistorical1dayEntry 2 }
snrFacilityHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal-to-Noise Ratio Mean"
::= { snrFacilityHistorical1dayEntry 3 }
snrFacilityHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal-to-Noise Ratio High"
::= { snrFacilityHistorical1dayEntry 4 }
snrFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { snrFacilityHistorical1dayEntry 5 }
snrFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { snrFacilityHistorical1dayEntry 6 }
endOfSnrFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 34 }
snrFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnrFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 35 }
snrFacilityHistorical1weekEntry OBJECT-TYPE
SYNTAX SnrFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
snrFacilityHistorical1weekNumber
}
::= { snrFacilityHistorical1weekTable 1 }
SnrFacilityHistorical1weekEntry ::= SEQUENCE
{ snrFacilityHistorical1weekNumber Integer32,
snrFacilityHistorical1weekLow Integer32,
snrFacilityHistorical1weekMean Integer32,
snrFacilityHistorical1weekHigh Integer32,
snrFacilityHistorical1weekValidFlag TruthValue,
snrFacilityHistorical1weekTimeStamp DateAndTime }
snrFacilityHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { snrFacilityHistorical1weekEntry 1 }
snrFacilityHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal-to-Noise Ratio Low"
::= { snrFacilityHistorical1weekEntry 2 }
snrFacilityHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal-to-Noise Ratio Mean"
::= { snrFacilityHistorical1weekEntry 3 }
snrFacilityHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal-to-Noise Ratio High"
::= { snrFacilityHistorical1weekEntry 4 }
snrFacilityHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { snrFacilityHistorical1weekEntry 5 }
snrFacilityHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { snrFacilityHistorical1weekEntry 6 }
endOfSnrFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 36 }
cfotFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfotFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 37 }
cfotFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX CfotFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
cfotFacilityHistorical15minNumber
}
::= { cfotFacilityHistorical15minTable 1 }
CfotFacilityHistorical15minEntry ::= SEQUENCE
{ cfotFacilityHistorical15minNumber Integer32,
cfotFacilityHistorical15minLow Integer32,
cfotFacilityHistorical15minMean Integer32,
cfotFacilityHistorical15minHigh Integer32,
cfotFacilityHistorical15minValidFlag TruthValue,
cfotFacilityHistorical15minTimeStamp DateAndTime }
cfotFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { cfotFacilityHistorical15minEntry 1 }
cfotFacilityHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 GHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier Frequency Offset Low"
::= { cfotFacilityHistorical15minEntry 2 }
cfotFacilityHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 GHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier Frequency Offset Mean"
::= { cfotFacilityHistorical15minEntry 3 }
cfotFacilityHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 GHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier Frequency Offset High"
::= { cfotFacilityHistorical15minEntry 4 }
cfotFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { cfotFacilityHistorical15minEntry 5 }
cfotFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { cfotFacilityHistorical15minEntry 6 }
endOfCfotFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 38 }
cfotFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfotFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 39 }
cfotFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX CfotFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
cfotFacilityHistorical1dayNumber
}
::= { cfotFacilityHistorical1dayTable 1 }
CfotFacilityHistorical1dayEntry ::= SEQUENCE
{ cfotFacilityHistorical1dayNumber Integer32,
cfotFacilityHistorical1dayLow Integer32,
cfotFacilityHistorical1dayMean Integer32,
cfotFacilityHistorical1dayHigh Integer32,
cfotFacilityHistorical1dayValidFlag TruthValue,
cfotFacilityHistorical1dayTimeStamp DateAndTime }
cfotFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { cfotFacilityHistorical1dayEntry 1 }
cfotFacilityHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 GHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier Frequency Offset Low"
::= { cfotFacilityHistorical1dayEntry 2 }
cfotFacilityHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 GHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier Frequency Offset Mean"
::= { cfotFacilityHistorical1dayEntry 3 }
cfotFacilityHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 GHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier Frequency Offset High"
::= { cfotFacilityHistorical1dayEntry 4 }
cfotFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { cfotFacilityHistorical1dayEntry 5 }
cfotFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { cfotFacilityHistorical1dayEntry 6 }
endOfCfotFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 40 }
cfotFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfotFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 41 }
cfotFacilityHistorical1weekEntry OBJECT-TYPE
SYNTAX CfotFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
cfotFacilityHistorical1weekNumber
}
::= { cfotFacilityHistorical1weekTable 1 }
CfotFacilityHistorical1weekEntry ::= SEQUENCE
{ cfotFacilityHistorical1weekNumber Integer32,
cfotFacilityHistorical1weekLow Integer32,
cfotFacilityHistorical1weekMean Integer32,
cfotFacilityHistorical1weekHigh Integer32,
cfotFacilityHistorical1weekValidFlag TruthValue,
cfotFacilityHistorical1weekTimeStamp DateAndTime }
cfotFacilityHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { cfotFacilityHistorical1weekEntry 1 }
cfotFacilityHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 GHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier Frequency Offset Low"
::= { cfotFacilityHistorical1weekEntry 2 }
cfotFacilityHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 GHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier Frequency Offset Mean"
::= { cfotFacilityHistorical1weekEntry 3 }
cfotFacilityHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 GHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier Frequency Offset High"
::= { cfotFacilityHistorical1weekEntry 4 }
cfotFacilityHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { cfotFacilityHistorical1weekEntry 5 }
cfotFacilityHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { cfotFacilityHistorical1weekEntry 6 }
endOfCfotFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 42 }
dgdFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF DgdFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 43 }
dgdFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX DgdFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
dgdFacilityHistorical15minNumber
}
::= { dgdFacilityHistorical15minTable 1 }
DgdFacilityHistorical15minEntry ::= SEQUENCE
{ dgdFacilityHistorical15minNumber Integer32,
dgdFacilityHistorical15minLow Integer32,
dgdFacilityHistorical15minMean Integer32,
dgdFacilityHistorical15minHigh Integer32,
dgdFacilityHistorical15minValidFlag TruthValue,
dgdFacilityHistorical15minTimeStamp DateAndTime }
dgdFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { dgdFacilityHistorical15minEntry 1 }
dgdFacilityHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential Group Delay Low"
::= { dgdFacilityHistorical15minEntry 2 }
dgdFacilityHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential Group Delay Mean"
::= { dgdFacilityHistorical15minEntry 3 }
dgdFacilityHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential Group Delay High"
::= { dgdFacilityHistorical15minEntry 4 }
dgdFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { dgdFacilityHistorical15minEntry 5 }
dgdFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { dgdFacilityHistorical15minEntry 6 }
endOfDgdFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 44 }
dgdFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF DgdFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 45 }
dgdFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX DgdFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
dgdFacilityHistorical1dayNumber
}
::= { dgdFacilityHistorical1dayTable 1 }
DgdFacilityHistorical1dayEntry ::= SEQUENCE
{ dgdFacilityHistorical1dayNumber Integer32,
dgdFacilityHistorical1dayLow Integer32,
dgdFacilityHistorical1dayMean Integer32,
dgdFacilityHistorical1dayHigh Integer32,
dgdFacilityHistorical1dayValidFlag TruthValue,
dgdFacilityHistorical1dayTimeStamp DateAndTime }
dgdFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { dgdFacilityHistorical1dayEntry 1 }
dgdFacilityHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential Group Delay Low"
::= { dgdFacilityHistorical1dayEntry 2 }
dgdFacilityHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential Group Delay Mean"
::= { dgdFacilityHistorical1dayEntry 3 }
dgdFacilityHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential Group Delay High"
::= { dgdFacilityHistorical1dayEntry 4 }
dgdFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { dgdFacilityHistorical1dayEntry 5 }
dgdFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { dgdFacilityHistorical1dayEntry 6 }
endOfDgdFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 46 }
dgdFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF DgdFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 47 }
dgdFacilityHistorical1weekEntry OBJECT-TYPE
SYNTAX DgdFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
dgdFacilityHistorical1weekNumber
}
::= { dgdFacilityHistorical1weekTable 1 }
DgdFacilityHistorical1weekEntry ::= SEQUENCE
{ dgdFacilityHistorical1weekNumber Integer32,
dgdFacilityHistorical1weekLow Integer32,
dgdFacilityHistorical1weekMean Integer32,
dgdFacilityHistorical1weekHigh Integer32,
dgdFacilityHistorical1weekValidFlag TruthValue,
dgdFacilityHistorical1weekTimeStamp DateAndTime }
dgdFacilityHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { dgdFacilityHistorical1weekEntry 1 }
dgdFacilityHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential Group Delay Low"
::= { dgdFacilityHistorical1weekEntry 2 }
dgdFacilityHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential Group Delay Mean"
::= { dgdFacilityHistorical1weekEntry 3 }
dgdFacilityHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential Group Delay High"
::= { dgdFacilityHistorical1weekEntry 4 }
dgdFacilityHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { dgdFacilityHistorical1weekEntry 5 }
dgdFacilityHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { dgdFacilityHistorical1weekEntry 6 }
endOfDgdFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 48 }
cdFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF CdFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 49 }
cdFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX CdFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
cdFacilityHistorical15minNumber
}
::= { cdFacilityHistorical15minTable 1 }
CdFacilityHistorical15minEntry ::= SEQUENCE
{ cdFacilityHistorical15minNumber Integer32,
cdFacilityHistorical15minLow Integer32,
cdFacilityHistorical15minMean Integer32,
cdFacilityHistorical15minHigh Integer32,
cdFacilityHistorical15minValidFlag TruthValue,
cdFacilityHistorical15minTimeStamp DateAndTime }
cdFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { cdFacilityHistorical15minEntry 1 }
cdFacilityHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Low"
::= { cdFacilityHistorical15minEntry 2 }
cdFacilityHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Mean"
::= { cdFacilityHistorical15minEntry 3 }
cdFacilityHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation High"
::= { cdFacilityHistorical15minEntry 4 }
cdFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { cdFacilityHistorical15minEntry 5 }
cdFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { cdFacilityHistorical15minEntry 6 }
endOfCdFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 50 }
cdFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF CdFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 51 }
cdFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX CdFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
cdFacilityHistorical1dayNumber
}
::= { cdFacilityHistorical1dayTable 1 }
CdFacilityHistorical1dayEntry ::= SEQUENCE
{ cdFacilityHistorical1dayNumber Integer32,
cdFacilityHistorical1dayLow Integer32,
cdFacilityHistorical1dayMean Integer32,
cdFacilityHistorical1dayHigh Integer32,
cdFacilityHistorical1dayValidFlag TruthValue,
cdFacilityHistorical1dayTimeStamp DateAndTime }
cdFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { cdFacilityHistorical1dayEntry 1 }
cdFacilityHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Low"
::= { cdFacilityHistorical1dayEntry 2 }
cdFacilityHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Mean"
::= { cdFacilityHistorical1dayEntry 3 }
cdFacilityHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation High"
::= { cdFacilityHistorical1dayEntry 4 }
cdFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { cdFacilityHistorical1dayEntry 5 }
cdFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { cdFacilityHistorical1dayEntry 6 }
endOfCdFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 52 }
cdFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF CdFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 53 }
cdFacilityHistorical1weekEntry OBJECT-TYPE
SYNTAX CdFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
cdFacilityHistorical1weekNumber
}
::= { cdFacilityHistorical1weekTable 1 }
CdFacilityHistorical1weekEntry ::= SEQUENCE
{ cdFacilityHistorical1weekNumber Integer32,
cdFacilityHistorical1weekLow Integer32,
cdFacilityHistorical1weekMean Integer32,
cdFacilityHistorical1weekHigh Integer32,
cdFacilityHistorical1weekValidFlag TruthValue,
cdFacilityHistorical1weekTimeStamp DateAndTime }
cdFacilityHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { cdFacilityHistorical1weekEntry 1 }
cdFacilityHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Low"
::= { cdFacilityHistorical1weekEntry 2 }
cdFacilityHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Mean"
::= { cdFacilityHistorical1weekEntry 3 }
cdFacilityHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation High"
::= { cdFacilityHistorical1weekEntry 4 }
cdFacilityHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { cdFacilityHistorical1weekEntry 5 }
cdFacilityHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { cdFacilityHistorical1weekEntry 6 }
endOfCdFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 54 }
latencyFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF LatencyFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 55 }
latencyFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX LatencyFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
latencyFacilityHistorical15minNumber
}
::= { latencyFacilityHistorical15minTable 1 }
LatencyFacilityHistorical15minEntry ::= SEQUENCE
{ latencyFacilityHistorical15minNumber Integer32,
latencyFacilityHistorical15minLow Unsigned32,
latencyFacilityHistorical15minMean Unsigned32,
latencyFacilityHistorical15minHigh Unsigned32,
latencyFacilityHistorical15minValidFlag TruthValue,
latencyFacilityHistorical15minTimeStamp DateAndTime }
latencyFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { latencyFacilityHistorical15minEntry 1 }
latencyFacilityHistorical15minLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 us"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay"
::= { latencyFacilityHistorical15minEntry 2 }
latencyFacilityHistorical15minMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 us"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay"
::= { latencyFacilityHistorical15minEntry 3 }
latencyFacilityHistorical15minHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 us"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay"
::= { latencyFacilityHistorical15minEntry 4 }
latencyFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { latencyFacilityHistorical15minEntry 5 }
latencyFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { latencyFacilityHistorical15minEntry 6 }
endOfLatencyFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 56 }
latencyFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF LatencyFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 57 }
latencyFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX LatencyFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
latencyFacilityHistorical1dayNumber
}
::= { latencyFacilityHistorical1dayTable 1 }
LatencyFacilityHistorical1dayEntry ::= SEQUENCE
{ latencyFacilityHistorical1dayNumber Integer32,
latencyFacilityHistorical1dayLow Unsigned32,
latencyFacilityHistorical1dayMean Unsigned32,
latencyFacilityHistorical1dayHigh Unsigned32,
latencyFacilityHistorical1dayValidFlag TruthValue,
latencyFacilityHistorical1dayTimeStamp DateAndTime }
latencyFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { latencyFacilityHistorical1dayEntry 1 }
latencyFacilityHistorical1dayLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 us"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay"
::= { latencyFacilityHistorical1dayEntry 2 }
latencyFacilityHistorical1dayMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 us"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay"
::= { latencyFacilityHistorical1dayEntry 3 }
latencyFacilityHistorical1dayHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 us"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay"
::= { latencyFacilityHistorical1dayEntry 4 }
latencyFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { latencyFacilityHistorical1dayEntry 5 }
latencyFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { latencyFacilityHistorical1dayEntry 6 }
endOfLatencyFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 58 }
latencyFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF LatencyFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 59 }
latencyFacilityHistorical1weekEntry OBJECT-TYPE
SYNTAX LatencyFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
latencyFacilityHistorical1weekNumber
}
::= { latencyFacilityHistorical1weekTable 1 }
LatencyFacilityHistorical1weekEntry ::= SEQUENCE
{ latencyFacilityHistorical1weekNumber Integer32,
latencyFacilityHistorical1weekLow Unsigned32,
latencyFacilityHistorical1weekMean Unsigned32,
latencyFacilityHistorical1weekHigh Unsigned32,
latencyFacilityHistorical1weekValidFlag TruthValue,
latencyFacilityHistorical1weekTimeStamp DateAndTime }
latencyFacilityHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { latencyFacilityHistorical1weekEntry 1 }
latencyFacilityHistorical1weekLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 us"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay"
::= { latencyFacilityHistorical1weekEntry 2 }
latencyFacilityHistorical1weekMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 us"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay"
::= { latencyFacilityHistorical1weekEntry 3 }
latencyFacilityHistorical1weekHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 us"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured round trip delay"
::= { latencyFacilityHistorical1weekEntry 4 }
latencyFacilityHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { latencyFacilityHistorical1weekEntry 5 }
latencyFacilityHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { latencyFacilityHistorical1weekEntry 6 }
endOfLatencyFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 60 }
cdcFacilityHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF CdcFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 61 }
cdcFacilityHistorical15minEntry OBJECT-TYPE
SYNTAX CdcFacilityHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
cdcFacilityHistorical15minNumber
}
::= { cdcFacilityHistorical15minTable 1 }
CdcFacilityHistorical15minEntry ::= SEQUENCE
{ cdcFacilityHistorical15minNumber Integer32,
cdcFacilityHistorical15minLow Integer32,
cdcFacilityHistorical15minMean Integer32,
cdcFacilityHistorical15minHigh Integer32,
cdcFacilityHistorical15minValidFlag TruthValue,
cdcFacilityHistorical15minTimeStamp DateAndTime }
cdcFacilityHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { cdcFacilityHistorical15minEntry 1 }
cdcFacilityHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Low"
::= { cdcFacilityHistorical15minEntry 2 }
cdcFacilityHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Mean"
::= { cdcFacilityHistorical15minEntry 3 }
cdcFacilityHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation High"
::= { cdcFacilityHistorical15minEntry 4 }
cdcFacilityHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { cdcFacilityHistorical15minEntry 5 }
cdcFacilityHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { cdcFacilityHistorical15minEntry 6 }
endOfCdcFacilityHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 62 }
cdcFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF CdcFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 63 }
cdcFacilityHistorical1dayEntry OBJECT-TYPE
SYNTAX CdcFacilityHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
cdcFacilityHistorical1dayNumber
}
::= { cdcFacilityHistorical1dayTable 1 }
CdcFacilityHistorical1dayEntry ::= SEQUENCE
{ cdcFacilityHistorical1dayNumber Integer32,
cdcFacilityHistorical1dayLow Integer32,
cdcFacilityHistorical1dayMean Integer32,
cdcFacilityHistorical1dayHigh Integer32,
cdcFacilityHistorical1dayValidFlag TruthValue,
cdcFacilityHistorical1dayTimeStamp DateAndTime }
cdcFacilityHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { cdcFacilityHistorical1dayEntry 1 }
cdcFacilityHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Low"
::= { cdcFacilityHistorical1dayEntry 2 }
cdcFacilityHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Mean"
::= { cdcFacilityHistorical1dayEntry 3 }
cdcFacilityHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation High"
::= { cdcFacilityHistorical1dayEntry 4 }
cdcFacilityHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { cdcFacilityHistorical1dayEntry 5 }
cdcFacilityHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { cdcFacilityHistorical1dayEntry 6 }
endOfCdcFacilityHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 64 }
cdcFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF CdcFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmFacilityPhysRecord 65 }
cdcFacilityHistorical1weekEntry OBJECT-TYPE
SYNTAX CdcFacilityHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityDcnShelfNo,
entityDcnSlotNo,
entityDcnPortNo,
entityDcnExtNo,
entityDcnClassName,
cdcFacilityHistorical1weekNumber
}
::= { cdcFacilityHistorical1weekTable 1 }
CdcFacilityHistorical1weekEntry ::= SEQUENCE
{ cdcFacilityHistorical1weekNumber Integer32,
cdcFacilityHistorical1weekLow Integer32,
cdcFacilityHistorical1weekMean Integer32,
cdcFacilityHistorical1weekHigh Integer32,
cdcFacilityHistorical1weekValidFlag TruthValue,
cdcFacilityHistorical1weekTimeStamp DateAndTime }
cdcFacilityHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { cdcFacilityHistorical1weekEntry 1 }
cdcFacilityHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Low"
::= { cdcFacilityHistorical1weekEntry 2 }
cdcFacilityHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation Mean"
::= { cdcFacilityHistorical1weekEntry 3 }
cdcFacilityHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chromatic Dispersion Compensation High"
::= { cdcFacilityHistorical1weekEntry 4 }
cdcFacilityHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { cdcFacilityHistorical1weekEntry 5 }
cdcFacilityHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { cdcFacilityHistorical1weekEntry 6 }
endOfCdcFacilityHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 66 }
endOfPmFacilityPhysRecord OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmFacilityPhysRecord 10000 }
terminPointPhysInstValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF TerminPointPhysInstValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmTerminPointPhysValue 1 }
terminPointPhysInstValueEntry OBJECT-TYPE
SYNTAX TerminPointPhysInstValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityTerminPointIndexNo1,
entityTerminPointIndexNo2,
entityTerminPointIndexNo3,
entityTerminPointIndexNo4,
entityTerminPointClassName
}
::= { terminPointPhysInstValueTable 1 }
TerminPointPhysInstValueEntry ::= SEQUENCE
{ terminPointPhysInstValueFiberConnAttenuation Integer32,
terminPointPhysInstValueInputPower Integer32,
terminPointPhysInstValueOutputPower Integer32 }
terminPointPhysInstValueFiberConnAttenuation OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fiber Connection Attenuation"
::= { terminPointPhysInstValueEntry 1 }
terminPointPhysInstValueInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Optical Input Power Received"
::= { terminPointPhysInstValueEntry 2 }
terminPointPhysInstValueOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Instantaneous Optical Power Transmitted (Output)"
::= { terminPointPhysInstValueEntry 3 }
endOfTerminPointPhysInstValueTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmTerminPointPhysValue 2 }
endOfPmTerminPointPhysical OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmTerminPointPhysValue 10000 }
dsOptMuxCurrent15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsOptMuxCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxDataRecord 1 }
dsOptMuxCurrent15minEntry OBJECT-TYPE
SYNTAX DsOptMuxCurrent15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName
}
::= { dsOptMuxCurrent15minTable 1 }
DsOptMuxCurrent15minEntry ::= SEQUENCE
{ dsOptMuxCurrent15minDS Unsigned32,
dsOptMuxCurrent15minElapsedTime Integer32 }
dsOptMuxCurrent15minDS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defect Seconds"
::= { dsOptMuxCurrent15minEntry 1 }
dsOptMuxCurrent15minElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..9000 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 15Min"
::= { dsOptMuxCurrent15minEntry 2 }
endOfDsOptMuxCurrent15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxDataRecord 2 }
dsOptMuxCurrent1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsOptMuxCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxDataRecord 3 }
dsOptMuxCurrent1dayEntry OBJECT-TYPE
SYNTAX DsOptMuxCurrent1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName
}
::= { dsOptMuxCurrent1dayTable 1 }
DsOptMuxCurrent1dayEntry ::= SEQUENCE
{ dsOptMuxCurrent1dayDS Unsigned32,
dsOptMuxCurrent1dayElapsedTime Integer32 }
dsOptMuxCurrent1dayDS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defect Seconds"
::= { dsOptMuxCurrent1dayEntry 1 }
dsOptMuxCurrent1dayElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..86400 | -2147483648)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed 1Day"
::= { dsOptMuxCurrent1dayEntry 2 }
endOfDsOptMuxCurrent1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxDataRecord 4 }
dsOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxDataRecord 5 }
dsOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX DsOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
dsOptMuxHistorical15minNumber
}
::= { dsOptMuxHistorical15minTable 1 }
DsOptMuxHistorical15minEntry ::= SEQUENCE
{ dsOptMuxHistorical15minNumber Integer32,
dsOptMuxHistorical15minDS Unsigned32,
dsOptMuxHistorical15minValidFlag TruthValue,
dsOptMuxHistorical15minTimeStamp DateAndTime }
dsOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { dsOptMuxHistorical15minEntry 1 }
dsOptMuxHistorical15minDS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defect Seconds"
::= { dsOptMuxHistorical15minEntry 2 }
dsOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { dsOptMuxHistorical15minEntry 3 }
dsOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { dsOptMuxHistorical15minEntry 4 }
endOfDsOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxDataRecord 6 }
dsOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxDataRecord 7 }
dsOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX DsOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
dsOptMuxHistorical1dayNumber
}
::= { dsOptMuxHistorical1dayTable 1 }
DsOptMuxHistorical1dayEntry ::= SEQUENCE
{ dsOptMuxHistorical1dayNumber Integer32,
dsOptMuxHistorical1dayDS Unsigned32,
dsOptMuxHistorical1dayValidFlag TruthValue,
dsOptMuxHistorical1dayTimeStamp DateAndTime }
dsOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { dsOptMuxHistorical1dayEntry 1 }
dsOptMuxHistorical1dayDS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defect Seconds"
::= { dsOptMuxHistorical1dayEntry 2 }
dsOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { dsOptMuxHistorical1dayEntry 3 }
dsOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { dsOptMuxHistorical1dayEntry 4 }
endOfDsOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxDataRecord 8 }
endOfPmOptMuxDataRecord OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxDataRecord 10000 }
optMuxPhysInstValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptMuxPhysInstValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysValue 1 }
optMuxPhysInstValueEntry OBJECT-TYPE
SYNTAX OptMuxPhysInstValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName
}
::= { optMuxPhysInstValueTable 1 }
OptMuxPhysInstValueEntry ::= SEQUENCE
{ optMuxPhysInstValueRemainingTime Unsigned32,
optMuxPhysInstValueLaserBiasCurrentLevelAverage Unsigned32,
optMuxPhysInstValueAttenuation Integer32,
optMuxPhysInstValueLaserBiasCurrentLevel Unsigned32,
optMuxPhysInstValueOscPowerReceived Integer32,
optMuxPhysInstValuePumpLaser1Temp Integer32,
optMuxPhysInstValuePumpLaser2Temp Integer32,
optMuxPhysInstValueAttenuationOfVoa Unsigned32,
optMuxPhysInstValueVariableGain Unsigned32,
optMuxPhysInstValuePumpLaser3Temp Integer32,
optMuxPhysInstValueLaserTemp Integer32,
optMuxPhysInstValueOutputPowerEsmt Integer32,
optMuxPhysInstValuePumpLaserBiasCurrent1 Unsigned32,
optMuxPhysInstValuePumpLaserBiasCurrent2 Unsigned32,
optMuxPhysInstValuePumpLaserBiasCurrent3 Unsigned32,
optMuxPhysInstValueOperatingHours Unsigned32,
optMuxPhysInstValueSubTemp Integer32,
optMuxPhysInstValuePumpLaser4Temp Integer32,
optMuxPhysInstValueTotalGainMeasurement Integer32,
optMuxPhysInstValueCurrentEdfaOpt Integer32,
optMuxPhysInstValuePumpLaserBiasCurrent4 Unsigned32,
optMuxPhysInstValueRxLineAttenuation Integer32,
optMuxPhysInstValueOscGain Unsigned32,
optMuxPhysInstValueBackreflectionPowerReceived Integer32,
optMuxPhysInstValueRamanEstSignalGain Unsigned32,
optMuxPhysInstValueOutputPower Integer32,
optMuxPhysInstValueInputPower Integer32,
optMuxPhysInstValueTxLineAttenuation Integer32,
optMuxPhysInstValueRamanPumpPower Integer32,
optMuxPhysInstValueOscOutputPower Integer32,
optMuxPhysInstValueBackreflectionTx Integer32,
optMuxPhysInstValuePowerPerChannelTx Integer32 }
optMuxPhysInstValueRemainingTime OBJECT-TYPE
SYNTAX Unsigned32
UNITS "min"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time Remaining for Completion of OTDR Measurement. The timer is set by an Operation with parameter 'MEASURE'"
::= { optMuxPhysInstValueEntry 1 }
optMuxPhysInstValueLaserBiasCurrentLevelAverage OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Level averaged over 10 seconds"
::= { optMuxPhysInstValueEntry 2 }
optMuxPhysInstValueAttenuation OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The attenuation in dB from the TRMT of the 1st stage to the RCV of the 2nd stage."
::= { optMuxPhysInstValueEntry 3 }
optMuxPhysInstValueLaserBiasCurrentLevel OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Level on demand"
::= { optMuxPhysInstValueEntry 4 }
optMuxPhysInstValueOscPowerReceived OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received Current"
::= { optMuxPhysInstValueEntry 5 }
optMuxPhysInstValuePumpLaser1Temp OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 1 Temperature"
::= { optMuxPhysInstValueEntry 6 }
optMuxPhysInstValuePumpLaser2Temp OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 2 Temperature"
::= { optMuxPhysInstValueEntry 7 }
optMuxPhysInstValueAttenuationOfVoa OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Variable Attenuator attenuation in dB"
::= { optMuxPhysInstValueEntry 8 }
optMuxPhysInstValueVariableGain OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Variable Gain of EDFA"
::= { optMuxPhysInstValueEntry 9 }
optMuxPhysInstValuePumpLaser3Temp OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 3 Temperature"
::= { optMuxPhysInstValueEntry 10 }
optMuxPhysInstValueLaserTemp OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Temperature"
::= { optMuxPhysInstValueEntry 11 }
optMuxPhysInstValueOutputPowerEsmt OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated Instantaneous Channel Power Transmitted"
::= { optMuxPhysInstValueEntry 12 }
optMuxPhysInstValuePumpLaserBiasCurrent1 OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Level for Laser Pump 1"
::= { optMuxPhysInstValueEntry 13 }
optMuxPhysInstValuePumpLaserBiasCurrent2 OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Level for Laser Pump 2"
::= { optMuxPhysInstValueEntry 14 }
optMuxPhysInstValuePumpLaserBiasCurrent3 OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Level for Laser Pump 3"
::= { optMuxPhysInstValueEntry 15 }
optMuxPhysInstValueOperatingHours OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 h"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Accumulated total of Operating Hours"
::= { optMuxPhysInstValueEntry 16 }
optMuxPhysInstValueSubTemp OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Submodule Temperature"
::= { optMuxPhysInstValueEntry 17 }
optMuxPhysInstValuePumpLaser4Temp OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 4 Temperature"
::= { optMuxPhysInstValueEntry 18 }
optMuxPhysInstValueTotalGainMeasurement OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Gain measured, sum of amplifier gain less other attenuation (such as VOA)."
::= { optMuxPhysInstValueEntry 19 }
optMuxPhysInstValueCurrentEdfaOpt OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total optical output power from the EDFA amplifier."
::= { optMuxPhysInstValueEntry 20 }
optMuxPhysInstValuePumpLaserBiasCurrent4 OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.001 A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Bias Current Level for Laser Pump 4"
::= { optMuxPhysInstValueEntry 21 }
optMuxPhysInstValueRxLineAttenuation OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attenuation of Receive Fiber"
::= { optMuxPhysInstValueEntry 22 }
optMuxPhysInstValueOscGain OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Raman OSC gain"
::= { optMuxPhysInstValueEntry 23 }
optMuxPhysInstValueBackreflectionPowerReceived OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Back Reflection Received Current"
::= { optMuxPhysInstValueEntry 24 }
optMuxPhysInstValueRamanEstSignalGain OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Estimated signal gain"
::= { optMuxPhysInstValueEntry 25 }
optMuxPhysInstValueOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Instantaneous Optical Power Transmitted (Output)"
::= { optMuxPhysInstValueEntry 26 }
optMuxPhysInstValueInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Optical Input Power Received"
::= { optMuxPhysInstValueEntry 27 }
optMuxPhysInstValueTxLineAttenuation OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attenuation of Transmit Fiber"
::= { optMuxPhysInstValueEntry 28 }
optMuxPhysInstValueRamanPumpPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total raman pump power"
::= { optMuxPhysInstValueEntry 29 }
optMuxPhysInstValueOscOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Instantaneous OSC Optical Power Transmitted (Output)"
::= { optMuxPhysInstValueEntry 30 }
optMuxPhysInstValueBackreflectionTx OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Physical Port Backreflection power, measured at Tx Port."
::= { optMuxPhysInstValueEntry 31 }
optMuxPhysInstValuePowerPerChannelTx OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Target output optical power for each channel."
::= { optMuxPhysInstValueEntry 32 }
endOfOptMuxPhysInstValueTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysValue 2 }
endOfPmOptMuxPhysValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysValue 10000 }
optMuxPhysThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptMuxPhysThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysThreshold 1 }
optMuxPhysThresholdEntry OBJECT-TYPE
SYNTAX OptMuxPhysThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName
}
::= { optMuxPhysThresholdTable 1 }
OptMuxPhysThresholdEntry ::= SEQUENCE
{ optMuxPhysThresholdRamanPumpPwrHighThres Integer32,
optMuxPhysThresholdRamanPumpPwrLowThres Integer32,
optMuxPhysThresholdPumpLaser1TempHighThres Integer32,
optMuxPhysThresholdPumpLaser1TempLowThres Integer32,
optMuxPhysThresholdPumpLaser2TempHighThres Integer32,
optMuxPhysThresholdPumpLaser2TempLowThres Integer32,
optMuxPhysThresholdPumpLaser3TempHighThres Integer32,
optMuxPhysThresholdPumpLaser3TempLowThres Integer32,
optMuxPhysThresholdPumpLaser4TempHighThres Integer32,
optMuxPhysThresholdPumpLaser4TempLowThres Integer32,
optMuxPhysThresholdUpperSubTempThres Integer32,
optMuxPhysThresholdbrtxHighConfig Integer32,
optMuxPhysThresholdBrPwrReceivedHighThres Integer32,
optMuxPhysThresholdOpticalInputPwrHigh Integer32,
optMuxPhysThresholdOpticalInputPwrLow Integer32,
optMuxPhysThresholdAprHighThreshold Unsigned32,
optMuxPhysThresholdConfigurableOpticalOutputPwrHigh Integer32,
optMuxPhysThresholdConfigurableOpticalOutputPwrLow Integer32,
optMuxPhysThresholdOpticalOutputPwrHigh Integer32,
optMuxPhysThresholdOpticalOutputPwrLow Integer32,
optMuxPhysThresholdLaserTempHighThres Integer32,
optMuxPhysThresholdLaserTempLowThres Integer32,
optMuxPhysThresholdOscPwrRcvHighThres Integer32,
optMuxPhysThresholdOscPwrRcvLowThres Integer32,
optMuxPhysThresholdAttTxHigh Integer32,
optMuxPhysThresholdAttTxLow Integer32,
optMuxPhysThresholdAttRxHigh Integer32,
optMuxPhysThresholdAttRxLow Integer32 }
optMuxPhysThresholdRamanPumpPwrHighThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Raman Pump Power High threshold"
::= { optMuxPhysThresholdEntry 1 }
optMuxPhysThresholdRamanPumpPwrLowThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Raman Pump Power Low threshold"
::= { optMuxPhysThresholdEntry 2 }
optMuxPhysThresholdPumpLaser1TempHighThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 1 temperature fixed high threshold."
::= { optMuxPhysThresholdEntry 3 }
optMuxPhysThresholdPumpLaser1TempLowThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 1 temperature fixed low threshold."
::= { optMuxPhysThresholdEntry 4 }
optMuxPhysThresholdPumpLaser2TempHighThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 2 temperature fixed high threshold."
::= { optMuxPhysThresholdEntry 5 }
optMuxPhysThresholdPumpLaser2TempLowThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 2 temperature fixed low threshold"
::= { optMuxPhysThresholdEntry 6 }
optMuxPhysThresholdPumpLaser3TempHighThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 3 temperature fixed high threshold"
::= { optMuxPhysThresholdEntry 7 }
optMuxPhysThresholdPumpLaser3TempLowThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 3 temperature fixed low threshold"
::= { optMuxPhysThresholdEntry 8 }
optMuxPhysThresholdPumpLaser4TempHighThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 4 temperature fixed high threshold"
::= { optMuxPhysThresholdEntry 9 }
optMuxPhysThresholdPumpLaser4TempLowThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser 4 temperature fixed low threshold"
::= { optMuxPhysThresholdEntry 10 }
optMuxPhysThresholdUpperSubTempThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Submodule High Temperature Threshold"
::= { optMuxPhysThresholdEntry 11 }
optMuxPhysThresholdbrtxHighConfig OBJECT-TYPE
SYNTAX Integer32 (-300..-180 | -2147483648)
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Backreflection power High Threshold, at Tx Port"
::= { optMuxPhysThresholdEntry 12 }
optMuxPhysThresholdBrPwrReceivedHighThres OBJECT-TYPE
SYNTAX Integer32 (-300..-180 | -2147483648)
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Backreflection Input Received High Threshold"
::= { optMuxPhysThresholdEntry 13 }
optMuxPhysThresholdOpticalInputPwrHigh OBJECT-TYPE
SYNTAX Integer32 (-450..260 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { optMuxPhysThresholdEntry 14 }
optMuxPhysThresholdOpticalInputPwrLow OBJECT-TYPE
SYNTAX Integer32 (-450..260 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { optMuxPhysThresholdEntry 15 }
optMuxPhysThresholdAprHighThreshold OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Automatic Power Reduction High Threshold"
::= { optMuxPhysThresholdEntry 16 }
optMuxPhysThresholdConfigurableOpticalOutputPwrHigh OBJECT-TYPE
SYNTAX Integer32 (-500..300 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configurable high threshold of the Optical Power Transmitted (output)"
::= { optMuxPhysThresholdEntry 17 }
optMuxPhysThresholdConfigurableOpticalOutputPwrLow OBJECT-TYPE
SYNTAX Integer32 (-500..300 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configurable threshold of the Optical Power Transmitted (output)"
::= { optMuxPhysThresholdEntry 18 }
optMuxPhysThresholdOpticalOutputPwrHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High fixed threshold of the Optical Power Transmitted (output)"
::= { optMuxPhysThresholdEntry 19 }
optMuxPhysThresholdOpticalOutputPwrLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low fixed threshold of the Optical Power Transmitted (output)"
::= { optMuxPhysThresholdEntry 20 }
optMuxPhysThresholdLaserTempHighThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser temperature fixed high threshold."
::= { optMuxPhysThresholdEntry 21 }
optMuxPhysThresholdLaserTempLowThres OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser temperature fixed low threshold."
::= { optMuxPhysThresholdEntry 22 }
optMuxPhysThresholdOscPwrRcvHighThres OBJECT-TYPE
SYNTAX Integer32 (-470..-50 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received High Threshold"
::= { optMuxPhysThresholdEntry 23 }
optMuxPhysThresholdOscPwrRcvLowThres OBJECT-TYPE
SYNTAX Integer32 (-470..-50 | -2147483648)
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received Low Threshold"
::= { optMuxPhysThresholdEntry 24 }
optMuxPhysThresholdAttTxHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High Threshold of Attenuation on Transmit Fiber"
::= { optMuxPhysThresholdEntry 25 }
optMuxPhysThresholdAttTxLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low Threshold Attenuation on Transmit Fiber"
::= { optMuxPhysThresholdEntry 26 }
optMuxPhysThresholdAttRxHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High Threshold for Attenuation on Receive Fiber"
::= { optMuxPhysThresholdEntry 27 }
optMuxPhysThresholdAttRxLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low Threshold for Attenuation on Receive Fiber."
::= { optMuxPhysThresholdEntry 28 }
endOfOptMuxPhysThresholdTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysThreshold 2 }
endOfPmOptMuxPhysThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysThreshold 10000 }
brTxOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrTxOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 1 }
brTxOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX BrTxOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
brTxOptMuxHistorical15minNumber
}
::= { brTxOptMuxHistorical15minTable 1 }
BrTxOptMuxHistorical15minEntry ::= SEQUENCE
{ brTxOptMuxHistorical15minNumber Integer32,
brTxOptMuxHistorical15minLow Integer32,
brTxOptMuxHistorical15minMean Integer32,
brTxOptMuxHistorical15minHigh Integer32,
brTxOptMuxHistorical15minValidFlag TruthValue,
brTxOptMuxHistorical15minTimeStamp DateAndTime }
brTxOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { brTxOptMuxHistorical15minEntry 1 }
brTxOptMuxHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backreflection Power Low, measured at Tx Port"
::= { brTxOptMuxHistorical15minEntry 2 }
brTxOptMuxHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backreflection Power Average, measured at Tx Port"
::= { brTxOptMuxHistorical15minEntry 3 }
brTxOptMuxHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backreflection Power High, measured at Tx Port"
::= { brTxOptMuxHistorical15minEntry 4 }
brTxOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { brTxOptMuxHistorical15minEntry 5 }
brTxOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { brTxOptMuxHistorical15minEntry 6 }
endOfBrTxOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 2 }
brTxOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrTxOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 3 }
brTxOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX BrTxOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
brTxOptMuxHistorical1dayNumber
}
::= { brTxOptMuxHistorical1dayTable 1 }
BrTxOptMuxHistorical1dayEntry ::= SEQUENCE
{ brTxOptMuxHistorical1dayNumber Integer32,
brTxOptMuxHistorical1dayLow Integer32,
brTxOptMuxHistorical1dayMean Integer32,
brTxOptMuxHistorical1dayHigh Integer32,
brTxOptMuxHistorical1dayValidFlag TruthValue,
brTxOptMuxHistorical1dayTimeStamp DateAndTime }
brTxOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { brTxOptMuxHistorical1dayEntry 1 }
brTxOptMuxHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backreflection Power Low, measured at Tx Port"
::= { brTxOptMuxHistorical1dayEntry 2 }
brTxOptMuxHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backreflection Power Average, measured at Tx Port"
::= { brTxOptMuxHistorical1dayEntry 3 }
brTxOptMuxHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backreflection Power High, measured at Tx Port"
::= { brTxOptMuxHistorical1dayEntry 4 }
brTxOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { brTxOptMuxHistorical1dayEntry 5 }
brTxOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { brTxOptMuxHistorical1dayEntry 6 }
endOfBrTxOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 4 }
brTxOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrTxOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 5 }
brTxOptMuxHistorical1weekEntry OBJECT-TYPE
SYNTAX BrTxOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
brTxOptMuxHistorical1weekNumber
}
::= { brTxOptMuxHistorical1weekTable 1 }
BrTxOptMuxHistorical1weekEntry ::= SEQUENCE
{ brTxOptMuxHistorical1weekNumber Integer32,
brTxOptMuxHistorical1weekLow Integer32,
brTxOptMuxHistorical1weekMean Integer32,
brTxOptMuxHistorical1weekHigh Integer32,
brTxOptMuxHistorical1weekValidFlag TruthValue,
brTxOptMuxHistorical1weekTimeStamp DateAndTime }
brTxOptMuxHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { brTxOptMuxHistorical1weekEntry 1 }
brTxOptMuxHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backreflection Power Low, measured at Tx Port"
::= { brTxOptMuxHistorical1weekEntry 2 }
brTxOptMuxHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backreflection Power Average, measured at Tx Port"
::= { brTxOptMuxHistorical1weekEntry 3 }
brTxOptMuxHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backreflection Power High, measured at Tx Port"
::= { brTxOptMuxHistorical1weekEntry 4 }
brTxOptMuxHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { brTxOptMuxHistorical1weekEntry 5 }
brTxOptMuxHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { brTxOptMuxHistorical1weekEntry 6 }
endOfBrTxOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 6 }
oscGainOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscGainOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 7 }
oscGainOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX OscGainOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oscGainOptMuxHistorical15minNumber
}
::= { oscGainOptMuxHistorical15minTable 1 }
OscGainOptMuxHistorical15minEntry ::= SEQUENCE
{ oscGainOptMuxHistorical15minNumber Integer32,
oscGainOptMuxHistorical15minLow Unsigned32,
oscGainOptMuxHistorical15minMean Unsigned32,
oscGainOptMuxHistorical15minHigh Unsigned32,
oscGainOptMuxHistorical15minValidFlag TruthValue,
oscGainOptMuxHistorical15minTimeStamp DateAndTime }
oscGainOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { oscGainOptMuxHistorical15minEntry 1 }
oscGainOptMuxHistorical15minLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Gain Low"
::= { oscGainOptMuxHistorical15minEntry 2 }
oscGainOptMuxHistorical15minMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Gain Average"
::= { oscGainOptMuxHistorical15minEntry 3 }
oscGainOptMuxHistorical15minHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Gain High"
::= { oscGainOptMuxHistorical15minEntry 4 }
oscGainOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oscGainOptMuxHistorical15minEntry 5 }
oscGainOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oscGainOptMuxHistorical15minEntry 6 }
endOfOscGainOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 8 }
oscGainOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscGainOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 9 }
oscGainOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX OscGainOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oscGainOptMuxHistorical1dayNumber
}
::= { oscGainOptMuxHistorical1dayTable 1 }
OscGainOptMuxHistorical1dayEntry ::= SEQUENCE
{ oscGainOptMuxHistorical1dayNumber Integer32,
oscGainOptMuxHistorical1dayLow Unsigned32,
oscGainOptMuxHistorical1dayMean Unsigned32,
oscGainOptMuxHistorical1dayHigh Unsigned32,
oscGainOptMuxHistorical1dayValidFlag TruthValue,
oscGainOptMuxHistorical1dayTimeStamp DateAndTime }
oscGainOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { oscGainOptMuxHistorical1dayEntry 1 }
oscGainOptMuxHistorical1dayLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Gain Low"
::= { oscGainOptMuxHistorical1dayEntry 2 }
oscGainOptMuxHistorical1dayMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Gain Average"
::= { oscGainOptMuxHistorical1dayEntry 3 }
oscGainOptMuxHistorical1dayHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Gain High"
::= { oscGainOptMuxHistorical1dayEntry 4 }
oscGainOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oscGainOptMuxHistorical1dayEntry 5 }
oscGainOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oscGainOptMuxHistorical1dayEntry 6 }
endOfOscGainOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 10 }
oscGainOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscGainOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 11 }
oscGainOptMuxHistorical1weekEntry OBJECT-TYPE
SYNTAX OscGainOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oscGainOptMuxHistorical1weekNumber
}
::= { oscGainOptMuxHistorical1weekTable 1 }
OscGainOptMuxHistorical1weekEntry ::= SEQUENCE
{ oscGainOptMuxHistorical1weekNumber Integer32,
oscGainOptMuxHistorical1weekLow Unsigned32,
oscGainOptMuxHistorical1weekMean Unsigned32,
oscGainOptMuxHistorical1weekHigh Unsigned32,
oscGainOptMuxHistorical1weekValidFlag TruthValue,
oscGainOptMuxHistorical1weekTimeStamp DateAndTime }
oscGainOptMuxHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { oscGainOptMuxHistorical1weekEntry 1 }
oscGainOptMuxHistorical1weekLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Gain Low"
::= { oscGainOptMuxHistorical1weekEntry 2 }
oscGainOptMuxHistorical1weekMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Gain Average"
::= { oscGainOptMuxHistorical1weekEntry 3 }
oscGainOptMuxHistorical1weekHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Gain High"
::= { oscGainOptMuxHistorical1weekEntry 4 }
oscGainOptMuxHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oscGainOptMuxHistorical1weekEntry 5 }
oscGainOptMuxHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oscGainOptMuxHistorical1weekEntry 6 }
endOfOscGainOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 12 }
atRcvOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtRcvOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 13 }
atRcvOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX AtRcvOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
atRcvOptMuxHistorical15minNumber
}
::= { atRcvOptMuxHistorical15minTable 1 }
AtRcvOptMuxHistorical15minEntry ::= SEQUENCE
{ atRcvOptMuxHistorical15minNumber Integer32,
atRcvOptMuxHistorical15minLow Integer32,
atRcvOptMuxHistorical15minMean Integer32,
atRcvOptMuxHistorical15minHigh Integer32,
atRcvOptMuxHistorical15minValidFlag TruthValue,
atRcvOptMuxHistorical15minTimeStamp DateAndTime }
atRcvOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { atRcvOptMuxHistorical15minEntry 1 }
atRcvOptMuxHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Attenuation on Receive Fiber"
::= { atRcvOptMuxHistorical15minEntry 2 }
atRcvOptMuxHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mean Attenuation on Receive Fiber"
::= { atRcvOptMuxHistorical15minEntry 3 }
atRcvOptMuxHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Attenuation on Receive Fiber"
::= { atRcvOptMuxHistorical15minEntry 4 }
atRcvOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { atRcvOptMuxHistorical15minEntry 5 }
atRcvOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { atRcvOptMuxHistorical15minEntry 6 }
endOfAtRcvOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 14 }
atRcvOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtRcvOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 15 }
atRcvOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX AtRcvOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
atRcvOptMuxHistorical1dayNumber
}
::= { atRcvOptMuxHistorical1dayTable 1 }
AtRcvOptMuxHistorical1dayEntry ::= SEQUENCE
{ atRcvOptMuxHistorical1dayNumber Integer32,
atRcvOptMuxHistorical1dayLow Integer32,
atRcvOptMuxHistorical1dayMean Integer32,
atRcvOptMuxHistorical1dayHigh Integer32,
atRcvOptMuxHistorical1dayValidFlag TruthValue,
atRcvOptMuxHistorical1dayTimeStamp DateAndTime }
atRcvOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { atRcvOptMuxHistorical1dayEntry 1 }
atRcvOptMuxHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Attenuation on Receive Fiber"
::= { atRcvOptMuxHistorical1dayEntry 2 }
atRcvOptMuxHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mean Attenuation on Receive Fiber"
::= { atRcvOptMuxHistorical1dayEntry 3 }
atRcvOptMuxHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Attenuation on Receive Fiber"
::= { atRcvOptMuxHistorical1dayEntry 4 }
atRcvOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { atRcvOptMuxHistorical1dayEntry 5 }
atRcvOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { atRcvOptMuxHistorical1dayEntry 6 }
endOfAtRcvOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 16 }
atRcvOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtRcvOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 17 }
atRcvOptMuxHistorical1weekEntry OBJECT-TYPE
SYNTAX AtRcvOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
atRcvOptMuxHistorical1weekNumber
}
::= { atRcvOptMuxHistorical1weekTable 1 }
AtRcvOptMuxHistorical1weekEntry ::= SEQUENCE
{ atRcvOptMuxHistorical1weekNumber Integer32,
atRcvOptMuxHistorical1weekLow Integer32,
atRcvOptMuxHistorical1weekMean Integer32,
atRcvOptMuxHistorical1weekHigh Integer32,
atRcvOptMuxHistorical1weekValidFlag TruthValue,
atRcvOptMuxHistorical1weekTimeStamp DateAndTime }
atRcvOptMuxHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { atRcvOptMuxHistorical1weekEntry 1 }
atRcvOptMuxHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Attenuation on Receive Fiber"
::= { atRcvOptMuxHistorical1weekEntry 2 }
atRcvOptMuxHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mean Attenuation on Receive Fiber"
::= { atRcvOptMuxHistorical1weekEntry 3 }
atRcvOptMuxHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Attenuation on Receive Fiber"
::= { atRcvOptMuxHistorical1weekEntry 4 }
atRcvOptMuxHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { atRcvOptMuxHistorical1weekEntry 5 }
atRcvOptMuxHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { atRcvOptMuxHistorical1weekEntry 6 }
endOfAtRcvOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 18 }
brOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 19 }
brOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX BrOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
brOptMuxHistorical15minNumber
}
::= { brOptMuxHistorical15minTable 1 }
BrOptMuxHistorical15minEntry ::= SEQUENCE
{ brOptMuxHistorical15minNumber Integer32,
brOptMuxHistorical15minLow Integer32,
brOptMuxHistorical15minMean Integer32,
brOptMuxHistorical15minHigh Integer32,
brOptMuxHistorical15minValidFlag TruthValue,
brOptMuxHistorical15minTimeStamp DateAndTime }
brOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { brOptMuxHistorical15minEntry 1 }
brOptMuxHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Back Reflection Received"
::= { brOptMuxHistorical15minEntry 2 }
brOptMuxHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Back Reflection Received Average"
::= { brOptMuxHistorical15minEntry 3 }
brOptMuxHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Back Reflection Received High"
::= { brOptMuxHistorical15minEntry 4 }
brOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { brOptMuxHistorical15minEntry 5 }
brOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { brOptMuxHistorical15minEntry 6 }
endOfBrOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 20 }
brOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 21 }
brOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX BrOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
brOptMuxHistorical1dayNumber
}
::= { brOptMuxHistorical1dayTable 1 }
BrOptMuxHistorical1dayEntry ::= SEQUENCE
{ brOptMuxHistorical1dayNumber Integer32,
brOptMuxHistorical1dayLow Integer32,
brOptMuxHistorical1dayMean Integer32,
brOptMuxHistorical1dayHigh Integer32,
brOptMuxHistorical1dayValidFlag TruthValue,
brOptMuxHistorical1dayTimeStamp DateAndTime }
brOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { brOptMuxHistorical1dayEntry 1 }
brOptMuxHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Back Reflection Received"
::= { brOptMuxHistorical1dayEntry 2 }
brOptMuxHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Back Reflection Received Average"
::= { brOptMuxHistorical1dayEntry 3 }
brOptMuxHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Back Reflection Received High"
::= { brOptMuxHistorical1dayEntry 4 }
brOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { brOptMuxHistorical1dayEntry 5 }
brOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { brOptMuxHistorical1dayEntry 6 }
endOfBrOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 22 }
brOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 23 }
brOptMuxHistorical1weekEntry OBJECT-TYPE
SYNTAX BrOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
brOptMuxHistorical1weekNumber
}
::= { brOptMuxHistorical1weekTable 1 }
BrOptMuxHistorical1weekEntry ::= SEQUENCE
{ brOptMuxHistorical1weekNumber Integer32,
brOptMuxHistorical1weekLow Integer32,
brOptMuxHistorical1weekMean Integer32,
brOptMuxHistorical1weekHigh Integer32,
brOptMuxHistorical1weekValidFlag TruthValue,
brOptMuxHistorical1weekTimeStamp DateAndTime }
brOptMuxHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { brOptMuxHistorical1weekEntry 1 }
brOptMuxHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Back Reflection Received"
::= { brOptMuxHistorical1weekEntry 2 }
brOptMuxHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Back Reflection Received Average"
::= { brOptMuxHistorical1weekEntry 3 }
brOptMuxHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Back Reflection Received High"
::= { brOptMuxHistorical1weekEntry 4 }
brOptMuxHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { brOptMuxHistorical1weekEntry 5 }
brOptMuxHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { brOptMuxHistorical1weekEntry 6 }
endOfBrOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 24 }
estSigGainOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF EstSigGainOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 25 }
estSigGainOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX EstSigGainOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
estSigGainOptMuxHistorical15minNumber
}
::= { estSigGainOptMuxHistorical15minTable 1 }
EstSigGainOptMuxHistorical15minEntry ::= SEQUENCE
{ estSigGainOptMuxHistorical15minNumber Integer32,
estSigGainOptMuxHistorical15minLow Unsigned32,
estSigGainOptMuxHistorical15minMean Unsigned32,
estSigGainOptMuxHistorical15minHigh Unsigned32,
estSigGainOptMuxHistorical15minValidFlag TruthValue,
estSigGainOptMuxHistorical15minTimeStamp DateAndTime }
estSigGainOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { estSigGainOptMuxHistorical15minEntry 1 }
estSigGainOptMuxHistorical15minLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated signal gain low"
::= { estSigGainOptMuxHistorical15minEntry 2 }
estSigGainOptMuxHistorical15minMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated signal gain average"
::= { estSigGainOptMuxHistorical15minEntry 3 }
estSigGainOptMuxHistorical15minHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated signal gain high"
::= { estSigGainOptMuxHistorical15minEntry 4 }
estSigGainOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { estSigGainOptMuxHistorical15minEntry 5 }
estSigGainOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { estSigGainOptMuxHistorical15minEntry 6 }
endOfEstSigGainOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 26 }
estSigGainOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF EstSigGainOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 27 }
estSigGainOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX EstSigGainOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
estSigGainOptMuxHistorical1dayNumber
}
::= { estSigGainOptMuxHistorical1dayTable 1 }
EstSigGainOptMuxHistorical1dayEntry ::= SEQUENCE
{ estSigGainOptMuxHistorical1dayNumber Integer32,
estSigGainOptMuxHistorical1dayLow Unsigned32,
estSigGainOptMuxHistorical1dayMean Unsigned32,
estSigGainOptMuxHistorical1dayHigh Unsigned32,
estSigGainOptMuxHistorical1dayValidFlag TruthValue,
estSigGainOptMuxHistorical1dayTimeStamp DateAndTime }
estSigGainOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { estSigGainOptMuxHistorical1dayEntry 1 }
estSigGainOptMuxHistorical1dayLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated signal gain low"
::= { estSigGainOptMuxHistorical1dayEntry 2 }
estSigGainOptMuxHistorical1dayMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated signal gain average"
::= { estSigGainOptMuxHistorical1dayEntry 3 }
estSigGainOptMuxHistorical1dayHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated signal gain high"
::= { estSigGainOptMuxHistorical1dayEntry 4 }
estSigGainOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { estSigGainOptMuxHistorical1dayEntry 5 }
estSigGainOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { estSigGainOptMuxHistorical1dayEntry 6 }
endOfEstSigGainOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 28 }
estSigGainOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF EstSigGainOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 29 }
estSigGainOptMuxHistorical1weekEntry OBJECT-TYPE
SYNTAX EstSigGainOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
estSigGainOptMuxHistorical1weekNumber
}
::= { estSigGainOptMuxHistorical1weekTable 1 }
EstSigGainOptMuxHistorical1weekEntry ::= SEQUENCE
{ estSigGainOptMuxHistorical1weekNumber Integer32,
estSigGainOptMuxHistorical1weekLow Unsigned32,
estSigGainOptMuxHistorical1weekMean Unsigned32,
estSigGainOptMuxHistorical1weekHigh Unsigned32,
estSigGainOptMuxHistorical1weekValidFlag TruthValue,
estSigGainOptMuxHistorical1weekTimeStamp DateAndTime }
estSigGainOptMuxHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { estSigGainOptMuxHistorical1weekEntry 1 }
estSigGainOptMuxHistorical1weekLow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated signal gain low"
::= { estSigGainOptMuxHistorical1weekEntry 2 }
estSigGainOptMuxHistorical1weekMean OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated signal gain average"
::= { estSigGainOptMuxHistorical1weekEntry 3 }
estSigGainOptMuxHistorical1weekHigh OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated signal gain high"
::= { estSigGainOptMuxHistorical1weekEntry 4 }
estSigGainOptMuxHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { estSigGainOptMuxHistorical1weekEntry 5 }
estSigGainOptMuxHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { estSigGainOptMuxHistorical1weekEntry 6 }
endOfEstSigGainOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 30 }
attrmtOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF AttrmtOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 31 }
attrmtOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX AttrmtOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
attrmtOptMuxHistorical15minNumber
}
::= { attrmtOptMuxHistorical15minTable 1 }
AttrmtOptMuxHistorical15minEntry ::= SEQUENCE
{ attrmtOptMuxHistorical15minNumber Integer32,
attrmtOptMuxHistorical15minLow Integer32,
attrmtOptMuxHistorical15minHigh Integer32,
attrmtOptMuxHistorical15minMean Integer32,
attrmtOptMuxHistorical15minValidFlag TruthValue,
attrmtOptMuxHistorical15minTimeStamp DateAndTime }
attrmtOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { attrmtOptMuxHistorical15minEntry 1 }
attrmtOptMuxHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Attenuation on Transmit Fiber"
::= { attrmtOptMuxHistorical15minEntry 2 }
attrmtOptMuxHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Attenuation on Transmit Fiber"
::= { attrmtOptMuxHistorical15minEntry 3 }
attrmtOptMuxHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mean Attenuation on Transmit Fiber"
::= { attrmtOptMuxHistorical15minEntry 4 }
attrmtOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { attrmtOptMuxHistorical15minEntry 5 }
attrmtOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { attrmtOptMuxHistorical15minEntry 6 }
endOfAttrmtOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 32 }
attrmtOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF AttrmtOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 33 }
attrmtOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX AttrmtOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
attrmtOptMuxHistorical1dayNumber
}
::= { attrmtOptMuxHistorical1dayTable 1 }
AttrmtOptMuxHistorical1dayEntry ::= SEQUENCE
{ attrmtOptMuxHistorical1dayNumber Integer32,
attrmtOptMuxHistorical1dayLow Integer32,
attrmtOptMuxHistorical1dayHigh Integer32,
attrmtOptMuxHistorical1dayMean Integer32,
attrmtOptMuxHistorical1dayValidFlag TruthValue,
attrmtOptMuxHistorical1dayTimeStamp DateAndTime }
attrmtOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { attrmtOptMuxHistorical1dayEntry 1 }
attrmtOptMuxHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Attenuation on Transmit Fiber"
::= { attrmtOptMuxHistorical1dayEntry 2 }
attrmtOptMuxHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Attenuation on Transmit Fiber"
::= { attrmtOptMuxHistorical1dayEntry 3 }
attrmtOptMuxHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mean Attenuation on Transmit Fiber"
::= { attrmtOptMuxHistorical1dayEntry 4 }
attrmtOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { attrmtOptMuxHistorical1dayEntry 5 }
attrmtOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { attrmtOptMuxHistorical1dayEntry 6 }
endOfAttrmtOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 34 }
attrmtOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF AttrmtOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 35 }
attrmtOptMuxHistorical1weekEntry OBJECT-TYPE
SYNTAX AttrmtOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
attrmtOptMuxHistorical1weekNumber
}
::= { attrmtOptMuxHistorical1weekTable 1 }
AttrmtOptMuxHistorical1weekEntry ::= SEQUENCE
{ attrmtOptMuxHistorical1weekNumber Integer32,
attrmtOptMuxHistorical1weekLow Integer32,
attrmtOptMuxHistorical1weekHigh Integer32,
attrmtOptMuxHistorical1weekMean Integer32,
attrmtOptMuxHistorical1weekValidFlag TruthValue,
attrmtOptMuxHistorical1weekTimeStamp DateAndTime }
attrmtOptMuxHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { attrmtOptMuxHistorical1weekEntry 1 }
attrmtOptMuxHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Attenuation on Transmit Fiber"
::= { attrmtOptMuxHistorical1weekEntry 2 }
attrmtOptMuxHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Attenuation on Transmit Fiber"
::= { attrmtOptMuxHistorical1weekEntry 3 }
attrmtOptMuxHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mean Attenuation on Transmit Fiber"
::= { attrmtOptMuxHistorical1weekEntry 4 }
attrmtOptMuxHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { attrmtOptMuxHistorical1weekEntry 5 }
attrmtOptMuxHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { attrmtOptMuxHistorical1weekEntry 6 }
endOfAttrmtOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 36 }
pumpPwrOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF PumpPwrOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 37 }
pumpPwrOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX PumpPwrOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
pumpPwrOptMuxHistorical15minNumber
}
::= { pumpPwrOptMuxHistorical15minTable 1 }
PumpPwrOptMuxHistorical15minEntry ::= SEQUENCE
{ pumpPwrOptMuxHistorical15minNumber Integer32,
pumpPwrOptMuxHistorical15minLow Integer32,
pumpPwrOptMuxHistorical15minMean Integer32,
pumpPwrOptMuxHistorical15minHigh Integer32,
pumpPwrOptMuxHistorical15minValidFlag TruthValue,
pumpPwrOptMuxHistorical15minTimeStamp DateAndTime }
pumpPwrOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { pumpPwrOptMuxHistorical15minEntry 1 }
pumpPwrOptMuxHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total raman pump power low"
::= { pumpPwrOptMuxHistorical15minEntry 2 }
pumpPwrOptMuxHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Raman Pump Power Received Average"
::= { pumpPwrOptMuxHistorical15minEntry 3 }
pumpPwrOptMuxHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total raman pump power High"
::= { pumpPwrOptMuxHistorical15minEntry 4 }
pumpPwrOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { pumpPwrOptMuxHistorical15minEntry 5 }
pumpPwrOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { pumpPwrOptMuxHistorical15minEntry 6 }
endOfPumpPwrOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 38 }
pumpPwrOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF PumpPwrOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 39 }
pumpPwrOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX PumpPwrOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
pumpPwrOptMuxHistorical1dayNumber
}
::= { pumpPwrOptMuxHistorical1dayTable 1 }
PumpPwrOptMuxHistorical1dayEntry ::= SEQUENCE
{ pumpPwrOptMuxHistorical1dayNumber Integer32,
pumpPwrOptMuxHistorical1dayLow Integer32,
pumpPwrOptMuxHistorical1dayMean Integer32,
pumpPwrOptMuxHistorical1dayHigh Integer32,
pumpPwrOptMuxHistorical1dayValidFlag TruthValue,
pumpPwrOptMuxHistorical1dayTimeStamp DateAndTime }
pumpPwrOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { pumpPwrOptMuxHistorical1dayEntry 1 }
pumpPwrOptMuxHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total raman pump power low"
::= { pumpPwrOptMuxHistorical1dayEntry 2 }
pumpPwrOptMuxHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Raman Pump Power Received Average"
::= { pumpPwrOptMuxHistorical1dayEntry 3 }
pumpPwrOptMuxHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total raman pump power High"
::= { pumpPwrOptMuxHistorical1dayEntry 4 }
pumpPwrOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { pumpPwrOptMuxHistorical1dayEntry 5 }
pumpPwrOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { pumpPwrOptMuxHistorical1dayEntry 6 }
endOfPumpPwrOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 40 }
pumpPwrOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF PumpPwrOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 41 }
pumpPwrOptMuxHistorical1weekEntry OBJECT-TYPE
SYNTAX PumpPwrOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
pumpPwrOptMuxHistorical1weekNumber
}
::= { pumpPwrOptMuxHistorical1weekTable 1 }
PumpPwrOptMuxHistorical1weekEntry ::= SEQUENCE
{ pumpPwrOptMuxHistorical1weekNumber Integer32,
pumpPwrOptMuxHistorical1weekLow Integer32,
pumpPwrOptMuxHistorical1weekMean Integer32,
pumpPwrOptMuxHistorical1weekHigh Integer32,
pumpPwrOptMuxHistorical1weekValidFlag TruthValue,
pumpPwrOptMuxHistorical1weekTimeStamp DateAndTime }
pumpPwrOptMuxHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { pumpPwrOptMuxHistorical1weekEntry 1 }
pumpPwrOptMuxHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total raman pump power low"
::= { pumpPwrOptMuxHistorical1weekEntry 2 }
pumpPwrOptMuxHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Raman Pump Power Received Average"
::= { pumpPwrOptMuxHistorical1weekEntry 3 }
pumpPwrOptMuxHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total raman pump power High"
::= { pumpPwrOptMuxHistorical1weekEntry 4 }
pumpPwrOptMuxHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { pumpPwrOptMuxHistorical1weekEntry 5 }
pumpPwrOptMuxHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { pumpPwrOptMuxHistorical1weekEntry 6 }
endOfPumpPwrOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 42 }
oscOptOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscOptOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 43 }
oscOptOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX OscOptOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oscOptOptMuxHistorical15minNumber
}
::= { oscOptOptMuxHistorical15minTable 1 }
OscOptOptMuxHistorical15minEntry ::= SEQUENCE
{ oscOptOptMuxHistorical15minNumber Integer32,
oscOptOptMuxHistorical15minLow Integer32,
oscOptOptMuxHistorical15minMean Integer32,
oscOptOptMuxHistorical15minHigh Integer32,
oscOptOptMuxHistorical15minValidFlag TruthValue,
oscOptOptMuxHistorical15minTimeStamp DateAndTime }
oscOptOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { oscOptOptMuxHistorical15minEntry 1 }
oscOptOptMuxHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Optical Output Power Transmitted"
::= { oscOptOptMuxHistorical15minEntry 2 }
oscOptOptMuxHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Optical Output Power Transmitted"
::= { oscOptOptMuxHistorical15minEntry 3 }
oscOptOptMuxHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Optical Output Power Transmitted"
::= { oscOptOptMuxHistorical15minEntry 4 }
oscOptOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oscOptOptMuxHistorical15minEntry 5 }
oscOptOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oscOptOptMuxHistorical15minEntry 6 }
endOfOscOptOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 44 }
oscOptOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscOptOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 45 }
oscOptOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX OscOptOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oscOptOptMuxHistorical1dayNumber
}
::= { oscOptOptMuxHistorical1dayTable 1 }
OscOptOptMuxHistorical1dayEntry ::= SEQUENCE
{ oscOptOptMuxHistorical1dayNumber Integer32,
oscOptOptMuxHistorical1dayLow Integer32,
oscOptOptMuxHistorical1dayMean Integer32,
oscOptOptMuxHistorical1dayHigh Integer32,
oscOptOptMuxHistorical1dayValidFlag TruthValue,
oscOptOptMuxHistorical1dayTimeStamp DateAndTime }
oscOptOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { oscOptOptMuxHistorical1dayEntry 1 }
oscOptOptMuxHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Optical Output Power Transmitted"
::= { oscOptOptMuxHistorical1dayEntry 2 }
oscOptOptMuxHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Optical Output Power Transmitted"
::= { oscOptOptMuxHistorical1dayEntry 3 }
oscOptOptMuxHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Optical Output Power Transmitted"
::= { oscOptOptMuxHistorical1dayEntry 4 }
oscOptOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oscOptOptMuxHistorical1dayEntry 5 }
oscOptOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oscOptOptMuxHistorical1dayEntry 6 }
endOfOscOptOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 46 }
oscOptOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscOptOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 47 }
oscOptOptMuxHistorical1weekEntry OBJECT-TYPE
SYNTAX OscOptOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oscOptOptMuxHistorical1weekNumber
}
::= { oscOptOptMuxHistorical1weekTable 1 }
OscOptOptMuxHistorical1weekEntry ::= SEQUENCE
{ oscOptOptMuxHistorical1weekNumber Integer32,
oscOptOptMuxHistorical1weekLow Integer32,
oscOptOptMuxHistorical1weekMean Integer32,
oscOptOptMuxHistorical1weekHigh Integer32,
oscOptOptMuxHistorical1weekValidFlag TruthValue,
oscOptOptMuxHistorical1weekTimeStamp DateAndTime }
oscOptOptMuxHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { oscOptOptMuxHistorical1weekEntry 1 }
oscOptOptMuxHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Optical Output Power Transmitted"
::= { oscOptOptMuxHistorical1weekEntry 2 }
oscOptOptMuxHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Optical Output Power Transmitted"
::= { oscOptOptMuxHistorical1weekEntry 3 }
oscOptOptMuxHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Optical Output Power Transmitted"
::= { oscOptOptMuxHistorical1weekEntry 4 }
oscOptOptMuxHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oscOptOptMuxHistorical1weekEntry 5 }
oscOptOptMuxHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oscOptOptMuxHistorical1weekEntry 6 }
endOfOscOptOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 48 }
oscPwrOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscPwrOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 49 }
oscPwrOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX OscPwrOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oscPwrOptMuxHistorical15minNumber
}
::= { oscPwrOptMuxHistorical15minTable 1 }
OscPwrOptMuxHistorical15minEntry ::= SEQUENCE
{ oscPwrOptMuxHistorical15minNumber Integer32,
oscPwrOptMuxHistorical15minLow Integer32,
oscPwrOptMuxHistorical15minMean Integer32,
oscPwrOptMuxHistorical15minHigh Integer32,
oscPwrOptMuxHistorical15minValidFlag TruthValue,
oscPwrOptMuxHistorical15minTimeStamp DateAndTime }
oscPwrOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { oscPwrOptMuxHistorical15minEntry 1 }
oscPwrOptMuxHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received Low"
::= { oscPwrOptMuxHistorical15minEntry 2 }
oscPwrOptMuxHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received Average"
::= { oscPwrOptMuxHistorical15minEntry 3 }
oscPwrOptMuxHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received High"
::= { oscPwrOptMuxHistorical15minEntry 4 }
oscPwrOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oscPwrOptMuxHistorical15minEntry 5 }
oscPwrOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oscPwrOptMuxHistorical15minEntry 6 }
endOfOscPwrOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 50 }
oscPwrOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscPwrOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 51 }
oscPwrOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX OscPwrOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oscPwrOptMuxHistorical1dayNumber
}
::= { oscPwrOptMuxHistorical1dayTable 1 }
OscPwrOptMuxHistorical1dayEntry ::= SEQUENCE
{ oscPwrOptMuxHistorical1dayNumber Integer32,
oscPwrOptMuxHistorical1dayLow Integer32,
oscPwrOptMuxHistorical1dayMean Integer32,
oscPwrOptMuxHistorical1dayHigh Integer32,
oscPwrOptMuxHistorical1dayValidFlag TruthValue,
oscPwrOptMuxHistorical1dayTimeStamp DateAndTime }
oscPwrOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { oscPwrOptMuxHistorical1dayEntry 1 }
oscPwrOptMuxHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received Low"
::= { oscPwrOptMuxHistorical1dayEntry 2 }
oscPwrOptMuxHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received Average"
::= { oscPwrOptMuxHistorical1dayEntry 3 }
oscPwrOptMuxHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received High"
::= { oscPwrOptMuxHistorical1dayEntry 4 }
oscPwrOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oscPwrOptMuxHistorical1dayEntry 5 }
oscPwrOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oscPwrOptMuxHistorical1dayEntry 6 }
endOfOscPwrOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 52 }
oscPwrOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscPwrOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 53 }
oscPwrOptMuxHistorical1weekEntry OBJECT-TYPE
SYNTAX OscPwrOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oscPwrOptMuxHistorical1weekNumber
}
::= { oscPwrOptMuxHistorical1weekTable 1 }
OscPwrOptMuxHistorical1weekEntry ::= SEQUENCE
{ oscPwrOptMuxHistorical1weekNumber Integer32,
oscPwrOptMuxHistorical1weekLow Integer32,
oscPwrOptMuxHistorical1weekMean Integer32,
oscPwrOptMuxHistorical1weekHigh Integer32,
oscPwrOptMuxHistorical1weekValidFlag TruthValue,
oscPwrOptMuxHistorical1weekTimeStamp DateAndTime }
oscPwrOptMuxHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { oscPwrOptMuxHistorical1weekEntry 1 }
oscPwrOptMuxHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received Low"
::= { oscPwrOptMuxHistorical1weekEntry 2 }
oscPwrOptMuxHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received Average"
::= { oscPwrOptMuxHistorical1weekEntry 3 }
oscPwrOptMuxHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Supervisory Channel Input Power Received High"
::= { oscPwrOptMuxHistorical1weekEntry 4 }
oscPwrOptMuxHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oscPwrOptMuxHistorical1weekEntry 5 }
oscPwrOptMuxHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oscPwrOptMuxHistorical1weekEntry 6 }
endOfOscPwrOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 54 }
optOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 55 }
optOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX OptOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
optOptMuxHistorical15minNumber
}
::= { optOptMuxHistorical15minTable 1 }
OptOptMuxHistorical15minEntry ::= SEQUENCE
{ optOptMuxHistorical15minNumber Integer32,
optOptMuxHistorical15minLow Integer32,
optOptMuxHistorical15minMean Integer32,
optOptMuxHistorical15minHigh Integer32,
optOptMuxHistorical15minValidFlag TruthValue,
optOptMuxHistorical15minTimeStamp DateAndTime }
optOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { optOptMuxHistorical15minEntry 1 }
optOptMuxHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optOptMuxHistorical15minEntry 2 }
optOptMuxHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optOptMuxHistorical15minEntry 3 }
optOptMuxHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optOptMuxHistorical15minEntry 4 }
optOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { optOptMuxHistorical15minEntry 5 }
optOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { optOptMuxHistorical15minEntry 6 }
endOfOptOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 56 }
optOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 57 }
optOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX OptOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
optOptMuxHistorical1dayNumber
}
::= { optOptMuxHistorical1dayTable 1 }
OptOptMuxHistorical1dayEntry ::= SEQUENCE
{ optOptMuxHistorical1dayNumber Integer32,
optOptMuxHistorical1dayLow Integer32,
optOptMuxHistorical1dayMean Integer32,
optOptMuxHistorical1dayHigh Integer32,
optOptMuxHistorical1dayValidFlag TruthValue,
optOptMuxHistorical1dayTimeStamp DateAndTime }
optOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { optOptMuxHistorical1dayEntry 1 }
optOptMuxHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optOptMuxHistorical1dayEntry 2 }
optOptMuxHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optOptMuxHistorical1dayEntry 3 }
optOptMuxHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optOptMuxHistorical1dayEntry 4 }
optOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { optOptMuxHistorical1dayEntry 5 }
optOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { optOptMuxHistorical1dayEntry 6 }
endOfOptOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 58 }
optOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 59 }
optOptMuxHistorical1weekEntry OBJECT-TYPE
SYNTAX OptOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
optOptMuxHistorical1weekNumber
}
::= { optOptMuxHistorical1weekTable 1 }
OptOptMuxHistorical1weekEntry ::= SEQUENCE
{ optOptMuxHistorical1weekNumber Integer32,
optOptMuxHistorical1weekLow Integer32,
optOptMuxHistorical1weekMean Integer32,
optOptMuxHistorical1weekHigh Integer32,
optOptMuxHistorical1weekValidFlag TruthValue,
optOptMuxHistorical1weekTimeStamp DateAndTime }
optOptMuxHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { optOptMuxHistorical1weekEntry 1 }
optOptMuxHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optOptMuxHistorical1weekEntry 2 }
optOptMuxHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optOptMuxHistorical1weekEntry 3 }
optOptMuxHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Output Power Transmitted"
::= { optOptMuxHistorical1weekEntry 4 }
optOptMuxHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { optOptMuxHistorical1weekEntry 5 }
optOptMuxHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { optOptMuxHistorical1weekEntry 6 }
endOfOptOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 60 }
oprOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF OprOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 61 }
oprOptMuxHistorical15minEntry OBJECT-TYPE
SYNTAX OprOptMuxHistorical15minEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oprOptMuxHistorical15minNumber
}
::= { oprOptMuxHistorical15minTable 1 }
OprOptMuxHistorical15minEntry ::= SEQUENCE
{ oprOptMuxHistorical15minNumber Integer32,
oprOptMuxHistorical15minLow Integer32,
oprOptMuxHistorical15minMean Integer32,
oprOptMuxHistorical15minHigh Integer32,
oprOptMuxHistorical15minValidFlag TruthValue,
oprOptMuxHistorical15minTimeStamp DateAndTime }
oprOptMuxHistorical15minNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 15 minute
interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1."
::= { oprOptMuxHistorical15minEntry 1 }
oprOptMuxHistorical15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprOptMuxHistorical15minEntry 2 }
oprOptMuxHistorical15minMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprOptMuxHistorical15minEntry 3 }
oprOptMuxHistorical15minHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprOptMuxHistorical15minEntry 4 }
oprOptMuxHistorical15minValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oprOptMuxHistorical15minEntry 5 }
oprOptMuxHistorical15minTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oprOptMuxHistorical15minEntry 6 }
endOfOprOptMuxHistorical15minTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 62 }
oprOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OprOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 63 }
oprOptMuxHistorical1dayEntry OBJECT-TYPE
SYNTAX OprOptMuxHistorical1dayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oprOptMuxHistorical1dayNumber
}
::= { oprOptMuxHistorical1dayTable 1 }
OprOptMuxHistorical1dayEntry ::= SEQUENCE
{ oprOptMuxHistorical1dayNumber Integer32,
oprOptMuxHistorical1dayLow Integer32,
oprOptMuxHistorical1dayMean Integer32,
oprOptMuxHistorical1dayHigh Integer32,
oprOptMuxHistorical1dayValidFlag TruthValue,
oprOptMuxHistorical1dayTimeStamp DateAndTime }
oprOptMuxHistorical1dayNumber OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number, which identifies the interval for
which the set of statistics is available. The interval
identified by 1 is the most recently completed 1 day
interval."
::= { oprOptMuxHistorical1dayEntry 1 }
oprOptMuxHistorical1dayLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprOptMuxHistorical1dayEntry 2 }
oprOptMuxHistorical1dayMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprOptMuxHistorical1dayEntry 3 }
oprOptMuxHistorical1dayHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprOptMuxHistorical1dayEntry 4 }
oprOptMuxHistorical1dayValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oprOptMuxHistorical1dayEntry 5 }
oprOptMuxHistorical1dayTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oprOptMuxHistorical1dayEntry 6 }
endOfOprOptMuxHistorical1dayTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 64 }
oprOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX SEQUENCE OF OprOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { pmOptMuxPhysRecord 65 }
oprOptMuxHistorical1weekEntry OBJECT-TYPE
SYNTAX OprOptMuxHistorical1weekEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX {
entityOpticalMuxShelfNo,
entityOpticalMuxSlotNo,
entityOpticalMuxPortNo,
entityOpticalMuxExtNo,
entityOpticalMuxClassName,
oprOptMuxHistorical1weekNumber
}
::= { oprOptMuxHistorical1weekTable 1 }
OprOptMuxHistorical1weekEntry ::= SEQUENCE
{ oprOptMuxHistorical1weekNumber Integer32,
oprOptMuxHistorical1weekLow Integer32,
oprOptMuxHistorical1weekMean Integer32,
oprOptMuxHistorical1weekHigh Integer32,
oprOptMuxHistorical1weekValidFlag TruthValue,
oprOptMuxHistorical1weekTimeStamp DateAndTime }
oprOptMuxHistorical1weekNumber OBJECT-TYPE
SYNTAX Integer32 (1..52)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number 1week"
::= { oprOptMuxHistorical1weekEntry 1 }
oprOptMuxHistorical1weekLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprOptMuxHistorical1weekEntry 2 }
oprOptMuxHistorical1weekMean OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprOptMuxHistorical1weekEntry 3 }
oprOptMuxHistorical1weekHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Input Power Received"
::= { oprOptMuxHistorical1weekEntry 4 }
oprOptMuxHistorical1weekValidFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid Flag"
::= { oprOptMuxHistorical1weekEntry 5 }
oprOptMuxHistorical1weekTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp"
::= { oprOptMuxHistorical1weekEntry 6 }
endOfOprOptMuxHistorical1weekTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 66 }
endOfPmOptMuxPhysRecord OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pmOptMuxPhysRecord 10000 }
END