ADTRAN-TA5K-GR909-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- TITLE: The ADTRAN GR909 MIB
|
|
-- PRODUCT: ADTRAN TA5K POTS PRODUCTS
|
|
|
|
-- This MIB defines the object identifier (OID) for the
|
|
-- ADTRAN GR909 MIB objects
|
|
|
|
-- The GR909 MIB defines the table for the GR-909 Loop Tests
|
|
-- 08/13/2009 och Fixed a problem that caused smicng.cmd to fail. adGenGr909BeginTest (define the INTEGER value)
|
|
-- DO NOT MAKE HISTORY COMMENTS HERE!!!! Revision history now in REVISION/DESCRIPTION clauses below
|
|
-- ******************************************************************************************
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
ifIndex
|
|
FROM IF-MIB
|
|
adGenGr909, adGenGr909ID
|
|
FROM ADTRAN-GENTA5K-MIB
|
|
;
|
|
|
|
adGenGr909MIB MODULE-IDENTITY
|
|
LAST-UPDATED "201202030832Z"
|
|
ORGANIZATION
|
|
"ADTRAN, Inc."
|
|
CONTACT-INFO
|
|
"CND Tech Support
|
|
Postal: ADTRAN, Inc.
|
|
901 Explorer Blvd.
|
|
Huntsville, AL 35806
|
|
Tel: +1 800 726-8663
|
|
Fax: +1 256 963 6217
|
|
E-mail: support@adtran.com"
|
|
|
|
DESCRIPTION
|
|
"Generic GR909 MIB"
|
|
|
|
REVISION "201203070000Z"
|
|
DESCRIPTION "PSK - Corrected a missing enum value in adGenGr909IdleNoiseResult OID"
|
|
|
|
REVISION "201202030832Z"
|
|
DESCRIPTION "Added Noise and Load Coil tests."
|
|
|
|
REVISION "200703300832Z"
|
|
DESCRIPTION "Created"
|
|
::= { adGenGr909ID 1 }
|
|
|
|
-- OBJECT IDENTIFIERS
|
|
|
|
adGenGr909Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenGr909Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of GR909 Table info."
|
|
::= { adGenGr909 1 }
|
|
|
|
adGenGr909Entry OBJECT-TYPE
|
|
SYNTAX AdGenGr909Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { ifIndex }
|
|
::= { adGenGr909Table 1 }
|
|
|
|
AdGenGr909Entry ::=
|
|
SEQUENCE {
|
|
adGenGr909HPTResult
|
|
INTEGER,
|
|
adGenGr909FEMFResult
|
|
INTEGER,
|
|
adGenGr909RFaultResult
|
|
INTEGER,
|
|
adGenGr909RingerResult
|
|
INTEGER,
|
|
adGenGr909ROHResult
|
|
INTEGER,
|
|
adGenGr909FVAcTipToGndMeas
|
|
DisplayString,
|
|
adGenGr909FVAcRingToGndMeas
|
|
DisplayString,
|
|
adGenGr909FVDcTipToGndMeas
|
|
DisplayString,
|
|
adGenGr909FVDcRingToGndMeas
|
|
DisplayString,
|
|
adGenGr909FVAcTipToGndResult
|
|
INTEGER,
|
|
adGenGr909FVAcRingToGndResult
|
|
INTEGER,
|
|
adGenGr909FVDcTipToGndResult
|
|
INTEGER,
|
|
adGenGr909FVDcRingToGndResult
|
|
INTEGER,
|
|
adGenGr909LoopImpTipToRingMeas
|
|
DisplayString,
|
|
adGenGr909LoopImpTipToGndMeas
|
|
DisplayString,
|
|
adGenGr909LoopImpRingToGndMeas
|
|
DisplayString,
|
|
adGenGr909LoopImpTipToRingResult
|
|
INTEGER,
|
|
adGenGr909LoopImpTipToGndResult
|
|
INTEGER,
|
|
adGenGr909LoopImpRingToGndResult
|
|
INTEGER,
|
|
adGenGr909RingerMeas
|
|
DisplayString,
|
|
adGenGr909LastTestComplete
|
|
DisplayString,
|
|
adGenGr909LastTestAttempt
|
|
DisplayString,
|
|
adGenGr909LastTestResult
|
|
INTEGER,
|
|
adGenGr909FailureCode
|
|
DisplayString,
|
|
adGenGr909BeginTest
|
|
INTEGER,
|
|
adGenGr909LoopCapTipToRingMeas
|
|
DisplayString,
|
|
adGenGr909LoopCapTipToGndMeas
|
|
DisplayString,
|
|
adGenGr909LoopCapRingToGndMeas
|
|
DisplayString,
|
|
adGenGr909IdleNoiseMeasure
|
|
Integer32,
|
|
adGenGr909IdleNoiseResult
|
|
INTEGER,
|
|
adGenGr909NumLoadCoils
|
|
INTEGER,
|
|
adGenGr909LoadCoilsDistance
|
|
OCTET STRING,
|
|
adGenGr909LoadCoilsResult
|
|
INTEGER,
|
|
adGenGr909TestFlag
|
|
INTEGER,
|
|
adGenGr909TestCapFlag
|
|
INTEGER,
|
|
adGenGr909TestNoiseFlag
|
|
INTEGER,
|
|
adGenGr909TestLoadCoilFlag
|
|
INTEGER
|
|
}
|
|
|
|
adGenGr909HPTResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2),
|
|
na(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This item indicates the result for the HPT test.
|
|
Pass(1) = The HPT test Passed.
|
|
Fail(2) = The HPT test failed.
|
|
N/A(3) = The HPT test result is not ready."
|
|
::= { adGenGr909Entry 1 }
|
|
|
|
adGenGr909FEMFResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2),
|
|
na(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This item indicates the result for the FEMF test.
|
|
Pass(1) = The FEMF test Passed.
|
|
Fail(2) = The FEMF test failed.
|
|
N/A(3) = The FEMF test result is not ready."
|
|
::= { adGenGr909Entry 2 }
|
|
|
|
adGenGr909RFaultResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2),
|
|
na(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This item indicates the result for the RFault test.
|
|
Pass(1) = The RFault test Passed.
|
|
Fail(2) = The RFault test failed.
|
|
N/A(3) = The RFault test result is not ready."
|
|
::= { adGenGr909Entry 3 }
|
|
|
|
adGenGr909RingerResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2),
|
|
na(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This item indicates the result for the Ringer test.
|
|
Pass(1) = The Ringer test Passed.
|
|
Fail(2) = The Ringer test failed.
|
|
N/A(3) = The Ringer test result is not ready."
|
|
::= { adGenGr909Entry 4 }
|
|
|
|
adGenGr909ROHResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2),
|
|
na(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This item indicates the result for the ROH test.
|
|
Pass(1) = The ROH test Passed.
|
|
Fail(2) = The ROH test failed.
|
|
N/A(3) = The ROH test result is not ready."
|
|
::= { adGenGr909Entry 5 }
|
|
|
|
adGenGr909FVAcTipToGndMeas OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the Foreign Voltage AC
|
|
Tip to Ground measurement."
|
|
::= { adGenGr909Entry 6 }
|
|
|
|
adGenGr909FVAcRingToGndMeas OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the Foreign Voltage AC
|
|
Ring to Ground measurement."
|
|
::= { adGenGr909Entry 7 }
|
|
|
|
adGenGr909FVDcTipToGndMeas OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the Foreign Voltage DC
|
|
Tip to Ground measurement."
|
|
::= { adGenGr909Entry 8 }
|
|
|
|
adGenGr909FVDcRingToGndMeas OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the Foreign Voltage DC
|
|
Ring to Ground measurement."
|
|
::= { adGenGr909Entry 9 }
|
|
|
|
adGenGr909FVAcTipToGndResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result for the Foreign Voltage AC
|
|
Tip to Ground test."
|
|
::= { adGenGr909Entry 10 }
|
|
|
|
adGenGr909FVAcRingToGndResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result for the Foreign Voltage AC
|
|
Ring to Ground test."
|
|
::= { adGenGr909Entry 11 }
|
|
|
|
adGenGr909FVDcTipToGndResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result for the Foreign Voltage DC
|
|
Tip to Ground test."
|
|
::= { adGenGr909Entry 12 }
|
|
|
|
adGenGr909FVDcRingToGndResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result for the Foreign Voltage DC
|
|
Ring to Ground test."
|
|
::= { adGenGr909Entry 13 }
|
|
|
|
adGenGr909LoopImpTipToRingMeas OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the Loop Impedance
|
|
Tip to Ring measurement."
|
|
::= { adGenGr909Entry 14 }
|
|
|
|
adGenGr909LoopImpTipToGndMeas OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the Loop Impedance
|
|
Tip to Ground measurement."
|
|
::= { adGenGr909Entry 15 }
|
|
|
|
adGenGr909LoopImpRingToGndMeas OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the Loop Impedance
|
|
Ring to Ground measurement."
|
|
::= { adGenGr909Entry 16 }
|
|
|
|
adGenGr909LoopImpTipToRingResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result for the Loop Impedance
|
|
Tip to Ring test."
|
|
::= { adGenGr909Entry 17 }
|
|
|
|
adGenGr909LoopImpTipToGndResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result for the Loop Impedance
|
|
Tip to Ground test."
|
|
::= { adGenGr909Entry 18 }
|
|
|
|
adGenGr909LoopImpRingToGndResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result for the Loop Impedance
|
|
Ring to Ground test."
|
|
::= { adGenGr909Entry 19 }
|
|
|
|
adGenGr909RingerMeas OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the Ringer measurement."
|
|
::= { adGenGr909Entry 20 }
|
|
|
|
adGenGr909LastTestComplete OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last test time the GR909 test was completed."
|
|
::= { adGenGr909Entry 21 }
|
|
|
|
adGenGr909LastTestAttempt OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last test time the GR909 test was completed."
|
|
::= { adGenGr909Entry 22 }
|
|
|
|
adGenGr909LastTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
na(1),
|
|
complete(2),
|
|
fault(3),
|
|
running(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This item indicates the result for the last test.
|
|
N/A(1) = The last test result is not valid.
|
|
Complete(2) = The last test is Complete.
|
|
Fault(3) = The last test had a fault.
|
|
Running(4) = The test is running."
|
|
::= { adGenGr909Entry 23 }
|
|
|
|
adGenGr909FailureCode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Failure Code for the last GR909 test."
|
|
::= { adGenGr909Entry 24 }
|
|
|
|
adGenGr909BeginTest OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
begin(1)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Begin running the GR909 test."
|
|
::= { adGenGr909Entry 25 }
|
|
|
|
adGenGr909LoopCapTipToRingMeas OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the Loop Capacitance
|
|
Tip to Ring measurement."
|
|
::= { adGenGr909Entry 26 }
|
|
|
|
adGenGr909LoopCapTipToGndMeas OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the Loop Capacitance
|
|
Tip to Ground measurement."
|
|
::= { adGenGr909Entry 27 }
|
|
|
|
adGenGr909LoopCapRingToGndMeas OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the Loop Capacitance
|
|
Ring to Ground measurement."
|
|
::= { adGenGr909Entry 28 }
|
|
|
|
adGenGr909IdleNoiseMeasure OBJECT-TYPE
|
|
SYNTAX Integer32 (0..120000)
|
|
UNITS "-0.001 dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Noise on the line."
|
|
::= { adGenGr909Entry 29 }
|
|
|
|
adGenGr909IdleNoiseResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pass(1),
|
|
fail(2),
|
|
na(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the noise measurement test on the line.
|
|
pass(1) = Idle Channel Noise Measurement passed.
|
|
fail(2) = Idle Channel Noise Measurement exceeded threshold.
|
|
na(3) = Idle Channel Measurement results are invalid, because
|
|
test has never been run, was not run in last test
|
|
sweep, or there was a fault during test execution."
|
|
::= { adGenGr909Entry 30 }
|
|
|
|
adGenGr909NumLoadCoils OBJECT-TYPE
|
|
SYNTAX INTEGER (0..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of load coils on the line."
|
|
::= { adGenGr909Entry 31 }
|
|
|
|
adGenGr909LoadCoilsDistance OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns a vector of 32-bit unsigned integers (split into octets)
|
|
containing the measured distance to each detected load coil
|
|
in feet.
|
|
If no load coil is detected then the system will return
|
|
a NULL. If one load coil is detected, then it will return four bytes
|
|
that will contain the distance in feet to that load coil from the node.
|
|
Similarly if a second load coil is detected then eight bytes
|
|
will be returned with the last four bytes containing the distance
|
|
to the second load coil from the node. Since this method allows
|
|
detection of up to 5 load coils, possibly 20 bytes containing the
|
|
distances to each of the coils from the node could be returned.
|
|
|
|
For example, a return of 0x00 00 04 1A 00 00 08 7F corresponds
|
|
to two load coils at distances of 1050 ft. and 2175 ft. from the node."
|
|
|
|
::= { adGenGr909Entry 32 }
|
|
|
|
adGenGr909LoadCoilsResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
invalid(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This item indicates the result for the load coils test.
|
|
Valid(1) = The load coil test results are valid.
|
|
Invalid(2) = The load coil test results are invalid."
|
|
::= { adGenGr909Entry 33 }
|
|
|
|
|
|
adGenGr909TestFlag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use to enable/disable the GR909 line tests."
|
|
::= { adGenGr909Entry 34 }
|
|
|
|
|
|
adGenGr909TestCapFlag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use to enable/disable the capacitance test on the line."
|
|
::= { adGenGr909Entry 35 }
|
|
|
|
|
|
adGenGr909TestNoiseFlag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use to enable/disable the noise test on the line."
|
|
::= { adGenGr909Entry 36 }
|
|
|
|
|
|
adGenGr909TestLoadCoilFlag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use to enable/disable the load coil tests on the line."
|
|
::= { adGenGr909Entry 37 }
|
|
|
|
|
|
END
|