Observium_CE/mibs/adtran/ADTRAN-TA5K-BULK-PM-MIB

145 lines
4.1 KiB
Plaintext

ADTRAN-TA5K-BULK-PM-MIB
DEFINITIONS ::= BEGIN
-- TITLE: The ADTRAN Total Access TA5000 Bulk PM MIB
-- PRODUCT: 1187020L1, 11872xx
-- VERSION: 1.0
-- DATE: July 18, 2007
-- This MIB allows the EMS to get the instance value for bulk PM gets
--
-- MIBs supported:
-- HISTORY:
-- 07/18/07 aed First edition
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32
FROM SNMPv2-SMI
adIdentity,
adIdentityShared,
adProducts,
adMgmt
FROM ADTRAN-MIB
adGenTa5kBulkPM,
adGenTa5kBulkPMID
FROM ADTRAN-GENTA5K-MIB
-- IANAifType
-- FROM IANAifType-MIB
-- sysName
-- FROM RFC1213-MIB
adGenPortInfoIndex
FROM ADTRAN-GENPORT-MIB
adGenSlotInfoIndex
FROM ADTRAN-GENSLOT-MIB;
-- *******************************************************************************
adTa5kBulkPMModuleIdentity MODULE-IDENTITY
LAST-UPDATED "200709200000Z"
ORGANIZATION
"ADTRAN, Inc."
CONTACT-INFO
"CND Tech Support
Postal: ADTRAN, Inc.
901 Explorer Blvd.
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"Total Access 5000 Bulk Performance Monitoring MIB"
::= { adGenTa5kBulkPMID 1 }
-- *******************************************************************************
adTa5kBulkPMSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdTa5kBulkPMSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"..."
::= { adGenTa5kBulkPM 1 }
adTa5kBulkPMSlotEntry OBJECT-TYPE
SYNTAX AdTa5kBulkPMSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index is the slot number."
INDEX { adGenSlotInfoIndex }
::= { adTa5kBulkPMSlotTable 1 }
AdTa5kBulkPMSlotEntry ::=
SEQUENCE {
adTa5kBulkPMSlotInstance Integer32,
adTa5kBulkPM15MinSlotInstance Integer32
}
adTa5kBulkPMSlotInstance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Used to index the Tlv table, each time this is called it
creates an instance for that viewer to read bulk PM data by slot."
::= { adTa5kBulkPMSlotEntry 1 }
adTa5kBulkPM15MinSlotInstance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Used to index the Tlv table, each time this is called it
creates an instance for that viewer to read 15 minute bulk PM data by slot."
::= { adTa5kBulkPMSlotEntry 2 }
-- *******************************************************************************
adTa5kBulkPMPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdTa5kBulkPMPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"..."
::= { adGenTa5kBulkPM 2 }
adTa5kBulkPMPortEntry OBJECT-TYPE
SYNTAX AdTa5kBulkPMPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indexes are the slot number and port number"
INDEX { adGenSlotInfoIndex, adGenPortInfoIndex }
::= { adTa5kBulkPMPortTable 1 }
AdTa5kBulkPMPortEntry ::=
SEQUENCE {
adTa5kBulkPMPortInstance Integer32
}
adTa5kBulkPMPortInstance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Used to index the Tlv table, each time this is called it
creates an instance for that viewer to read bulk PM data by slot and port."
::= { adTa5kBulkPMPortEntry 1 }
END