DEFINITIONS ::= BEGIN
-- TITLE: The ADTRAN Total Access 5000 Gen ATM Line Modules
-- PRODUCT: 1187200L1, 1187201L1, 1187210L1, 1187211L1
-- VERSION: 1.0
-- DATE: April 24, 2007
-- This MIB defines the object identifier (OID) for the Total Access
-- 5000 Line Modules containing ATM interfaces.
-- MIBs supported:
-- None
-- HISTORY:
-- Mar. 09, 2007 GLF Added to TACore based of the product specific mib for the ATM Line Modules to use
-- Apr. 22, 2008 AD Add support for VP Switching
-- Apr. 24, 2008 DCC Add support for selecting up to 32 ports for timing
-- Oct. 31, 2008 DCC Add support for bandwidth utilization stats
-- 7/06/2009 jlb Corrected SMICng compile errors
-- 11/20/2009 glf add missing OIDs in the adGenTa5kAtmVpStatusTable that already have RMD support
-- 02/16/2010 glf add Vcl learned count OID (adGenTa5kAtmLMCardVclLearnedCount).
-- 08/17/2010 glf add AAL5 stats to the adGenTa5kAtmVplStatsTable, needed for WebGUI.
-- 01/18/2010 glf add adGenTa5kAtmLMCardCurrentOAMID and adGenTa5kAtmLMCardFutureOAMID to the adGenTa5kAtmLMCardProvTable
-- 01/27/2011 glf filled in missing descriptions
-- DO NOT ADD REVISION INFORMATION HERE
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32, Gauge32, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, TruthValue, MacAddress
FROM SNMPv2-TC
ifIndex
FROM IF-MIB
-- sysName
-- FROM RFC1213-MIB
adGenSlotInfoIndex
FROM ADTRAN-GENSLOT-MIB
atmVclVpi, atmVclVci, atmVplVpi
FROM ATM-MIB
adTrapInformSeqNum
FROM ADTRAN-GENTRAPINFORM-MIB
sysName
FROM SNMPv2-MIB
adGenTa5kAtmLM, adGenTa5kAtmLMID
FROM ADTRAN-GENTA5K-MIB;
-- *********************************************************************************************************
adTa5kAtmLMModuleIdentity MODULE-IDENTITY
LAST-UPDATED "201308050000Z"
ORGANIZATION
"ADTRAN, Inc."
CONTACT-INFO
"CND Tech Support
Postal: ADTRAN, Inc.
901 Explorer Blvd.
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"Total Access 5000 ATM LM MIB"
REVISION "201308050000Z"
DESCRIPTION "Added new OID adGenTa5kAtmPortProvShapingUBR to the adGenTa5kAtmPortProvisioningTable Table."
REVISION "201201300000Z"
DESCRIPTION "Added OIDs to reset DHCP card level PM history and rolling counters."
REVISION "201201040000Z"
DESCRIPTION "Added DHCP Relay Agent PM history counters at the ATM interface and card level"
REVISION "201110070000Z"
DESCRIPTION "Added an OID to provision DHCP Option 82 Circuit ID string for an ATM port"
REVISION "201108310000Z"
DESCRIPTION "Added OID to return cell delineation status for an ATM port"
REVISION "201106010000Z"
DESCRIPTION "Added OIDs to retrieve VCL and VPL connection information"
REVISION "201104140000Z"
DESCRIPTION "Added OIDs for free-rolling counters"
::= { adGenTa5kAtmLMID 1 }
-- OBJECT IDENTIFIERS
adGenTa5kAtmLMConfig OBJECT IDENTIFIER ::= { adGenTa5kAtmLM 1 }
adGenTa5kAtmLMProvisioning OBJECT IDENTIFIER ::= { adGenTa5kAtmLM 2 }
adGenTa5kAtmLMPMStats OBJECT IDENTIFIER ::= { adGenTa5kAtmLM 3 }
adGenTa5kAtmLMVpStatus OBJECT IDENTIFIER ::= { adGenTa5kAtmLM 4 }
adGenTa5kAtmLMAlarmPrefix OBJECT IDENTIFIER ::= { adGenTa5kAtmLM 5 }
adGenTa5kAtmLMAlarm OBJECT IDENTIFIER ::= { adGenTa5kAtmLMAlarmPrefix 0 }
-- *********************************************************************************************************
adGenTa5kAtmLMConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmLMConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM Line Module Configuration"
::= { adGenTa5kAtmLMConfig 1 }
adGenTa5kAtmLMConfigEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmLMConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { adGenSlotInfoIndex}
::= { adGenTa5kAtmLMConfigTable 1 }
AdGenTa5kAtmLMConfigEntry ::=
SEQUENCE {
adGenTa5kAtmLMConfigBootCodeRev DisplayString,
adGenTa5kAtmLMConfigSystemSWRev DisplayString,
adGenTa5kAtmLMConfigBootSysSWRev DisplayString,
adGenTa5kAtmLMConfigMacAddress MacAddress,
adGenTa5kAtmLMConfigFPGARev DisplayString,
adGenTa5kAtmLMConfigCPLDRev DisplayString,
adGenTa5kAtmLMConfigWDDIRev DisplayString,
adGenTa5kAtmLMConfigDPSRev DisplayString
}
adGenTa5kAtmLMConfigBootCodeRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns Code revision for the boot code xxx.xxx format"
::= { adGenTa5kAtmLMConfigEntry 1 }
adGenTa5kAtmLMConfigSystemSWRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns code revision for the application code in the system format xx.xx.xx.xx"
::= { adGenTa5kAtmLMConfigEntry 2 }
adGenTa5kAtmLMConfigBootSysSWRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns code revision for the boot code in the system format xx.xx.xx.xx.xx"
::= { adGenTa5kAtmLMConfigEntry 3 }
adGenTa5kAtmLMConfigMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the MAC address of the card"
::= { adGenTa5kAtmLMConfigEntry 4 }
adGenTa5kAtmLMConfigFPGARev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the FPGA revision"
::= { adGenTa5kAtmLMConfigEntry 5 }
adGenTa5kAtmLMConfigCPLDRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the CPLD Revision"
::= { adGenTa5kAtmLMConfigEntry 6 }
adGenTa5kAtmLMConfigWDDIRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Resturns the WDDI revision"
::= { adGenTa5kAtmLMConfigEntry 7 }
adGenTa5kAtmLMConfigDPSRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the DPS revision"
::= { adGenTa5kAtmLMConfigEntry 8 }
-- *********************************************************************************************************
adGenTa5kAtmPortProvisioningTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmPortProvisioningEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM Port Provisioning"
::= { adGenTa5kAtmLMProvisioning 1}
adGenTa5kAtmPortProvisioningEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmPortProvisioningEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex}
::= { adGenTa5kAtmPortProvisioningTable 1 }
AdGenTa5kAtmPortProvisioningEntry ::=
SEQUENCE {
adGenTa5kAtmPortProvPortID DisplayString,
adGenTa5kAtmPortProvPortType INTEGER,
adGenTa5kAtmPortProvScrambler INTEGER,
adGenTa5kAtmPortProvIdleCellType INTEGER,
adGenTa5kAtmPortProvMaxVccs Integer32,
adGenTa5kAtmPortProvAISRDIGen INTEGER,
adGenTa5kAtmPortProvInterfaceMode INTEGER,
adGenTa5kAtmPortProvDhcpCircuitIdFormat DisplayString,
adGenTa5kAtmPortProvShapingUBR INTEGER
}
adGenTa5kAtmPortProvPortID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"used to set ID of the ATM Port"
::= { adGenTa5kAtmPortProvisioningEntry 1 }
adGenTa5kAtmPortProvPortType OBJECT-TYPE
SYNTAX INTEGER {
uni(1),
nni(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"UNI/NNI provisioning"
::= { adGenTa5kAtmPortProvisioningEntry 2 }
adGenTa5kAtmPortProvScrambler OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"used to enable/disable cell scrambling on an ATM Port"
::= { adGenTa5kAtmPortProvisioningEntry 3 }
adGenTa5kAtmPortProvIdleCellType OBJECT-TYPE
SYNTAX INTEGER {
bellcore(1),
itu(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"used to set the idle cell type on an ATM port"
::= { adGenTa5kAtmPortProvisioningEntry 4 }
adGenTa5kAtmPortProvMaxVccs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum Vccs Allowed on this port"
::= { adGenTa5kAtmPortProvisioningEntry 5 }
adGenTa5kAtmPortProvAISRDIGen OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"used to enable/disable AIS/RDI generation"
::= { adGenTa5kAtmPortProvisioningEntry 6 }
adGenTa5kAtmPortProvInterfaceMode OBJECT-TYPE
SYNTAX INTEGER {
uplink(1),
aggregation(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if this interface is used for uplink or aggregation"
::= { adGenTa5kAtmPortProvisioningEntry 7 }
adGenTa5kAtmPortProvDhcpCircuitIdFormat OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to provision the format of the circuit ID string. This string is used
to provision DHCP Option 82 sub-option 1 cirduit id that will be added to
the DHCP messages.
TR-101 states that the format of the circuit ID
should be user defineable. The string may contain both fixed
static string elements specified by the user and also variable
and fixed length elements which are populated by the network
element. Variable length elements are specified by enclosing
the names of the variables with a dollar sign '$'. For instance,
a user could specify a circuit id string as follows:
'TA1148-$accessnodeid$ Port: $port$ $vpi$/$vci$'
which would expand to
'TA1148-TID Port: 1 0/35'.
In this implementation, the access-node-id is equivalent to the
system's provisioned TID or SNMP sysName. If this string is
provisioned zero-length, then the default format is used.
The total length of the expanded string MUST NOT exceed
63 characters.
Variables include (but are not limited to) the following:
Variable Name Character Length
accessnodeid Varies
slot 3
port 3
vpi 4
vci 5
If a user defined circuit ID is not desired, this object can
be set to simply 'default' and the default format described in
TR-101 will be used:
access-node-id atm slot/port:vpi.vci"
::= { adGenTa5kAtmPortProvisioningEntry 8}
adGenTa5kAtmPortProvShapingUBR OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if this interface activates ubr shaping"
DEFVAL { disable }
::= { adGenTa5kAtmPortProvisioningEntry 9 }
-- *********************************************************************************************************
adGenTa5kManagementChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kManagementChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Management Provisioning"
::= { adGenTa5kAtmLMProvisioning 2 }
adGenTa5kManagementChannelEntry OBJECT-TYPE
SYNTAX AdGenTa5kManagementChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { adGenSlotInfoIndex}
::= { adGenTa5kManagementChannelTable 1 }
AdGenTa5kManagementChannelEntry ::=
SEQUENCE {
adGenTa5kManagementChannelVpi INTEGER,
adGenTa5kManagementChannelVci INTEGER,
adGenTa5kManagementChannelMode INTEGER,
adGenTa5kManagementChannelEncap INTEGER,
adGenTa5kManagementChannelMultiplex INTEGER,
adGenTa5kManagementChannelEnable INTEGER,
adGenTa5kManagementChannelPort Integer32
}
adGenTa5kManagementChannelVpi OBJECT-TYPE
SYNTAX INTEGER (1..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Vpi of the management channel"
::= { adGenTa5kManagementChannelEntry 1 }
adGenTa5kManagementChannelVci OBJECT-TYPE
SYNTAX INTEGER (1..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Vci of the management channel"
::= { adGenTa5kManagementChannelEntry 2 }
adGenTa5kManagementChannelMode OBJECT-TYPE
SYNTAX INTEGER {
routed(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"used to set the mode of the management channel"
::= { adGenTa5kManagementChannelEntry 3 }
adGenTa5kManagementChannelEncap OBJECT-TYPE
SYNTAX INTEGER {
vcMultiplexRoutedProtocol(1),
vcMultiplexBridgedProtocol8023(2),
vcMultiplexBridgedProtocol8025(3),
vcMultiplexBridgedProtocol8026(4),
vcMultiplexLANemulation8023(5),
vcMultiplexLANemulation8025(6),
llcEncapsulation(7),
multiprotocolFrameRelaySscs(8),
other(9),
unknown(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"used to set the encapsulation type of the management channel"
::= { adGenTa5kManagementChannelEntry 4 }
adGenTa5kManagementChannelMultiplex OBJECT-TYPE
SYNTAX INTEGER {
llc(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { adGenTa5kManagementChannelEntry 5 }
adGenTa5kManagementChannelEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"used to enable/disable the management channel"
::= { adGenTa5kManagementChannelEntry 6 }
adGenTa5kManagementChannelPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"used to set which port is the management channel"
::= { adGenTa5kManagementChannelEntry 7 }
-- *********************************************************************************************************
adGenTa5kAtmLMSWUploadTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmLMSWUploadEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Software Upload"
::= { adGenTa5kAtmLMProvisioning 3}
adGenTa5kAtmLMSWUploadEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmLMSWUploadEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { adGenSlotInfoIndex}
::= { adGenTa5kAtmLMSWUploadTable 1 }
AdGenTa5kAtmLMSWUploadEntry ::=
SEQUENCE {
adGenTa5kAtmLMReboot Integer32
}
adGenTa5kAtmLMReboot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"used to reboot the card"
::= { adGenTa5kAtmLMSWUploadEntry 1 }
-- *********************************************************************************************************
adGenTa5kAtmLMCardProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmLMCardProvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Card Level Provisioning"
::= { adGenTa5kAtmLMProvisioning 4}
adGenTa5kAtmLMCardProvEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmLMCardProvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { adGenSlotInfoIndex}
::= { adGenTa5kAtmLMCardProvTable 1 }
AdGenTa5kAtmLMCardProvEntry ::=
SEQUENCE {
adGenTa5kAtmLMCardProvLearningMode INTEGER,
adGenTa5kAtmLMCardVclLearnedCount Integer32,
adGenTa5kAtmLMCardCurrentOAMID OCTET STRING,
adGenTa5kAtmLMCardFutureOAMID OCTET STRING,
adGenTa5kAtmLMCardResetDHCPPMStats INTEGER,
adGenTa5kAtmLMCardResetDHCPRollingCounters INTEGER
}
adGenTa5kAtmLMCardProvLearningMode OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Learning Mode"
::= { adGenTa5kAtmLMCardProvEntry 1 }
adGenTa5kAtmLMCardVclLearnedCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"returns the number of VCLs learned"
::= { adGenTa5kAtmLMCardProvEntry 2 }
adGenTa5kAtmLMCardCurrentOAMID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Card Level OAM Identification that is currently used"
::= { adGenTa5kAtmLMCardProvEntry 3 }
adGenTa5kAtmLMCardFutureOAMID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object is used to set the OAM ID for the specified access module.
Some access modules must be restarted in order for the new OAM ID to take effect.
To determine if a reboot is required, retrieve both the adGenTa5kAtmLMCardFutureOAMID
and the adGenTa5kAtmLMCardCurrentOAMID after a successful set and compare the returned
values. If the values are different, the access module will have to be rebooted for the
OAM ID to take effect. If the values are equivalent, the OAM ID took effect immediately
and no reboot is required"
::= { adGenTa5kAtmLMCardProvEntry 4 }
adGenTa5kAtmLMCardResetDHCPPMStats OBJECT-TYPE
SYNTAX INTEGER { reset(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set will reset all dhcp card level pm stats"
::= { adGenTa5kAtmLMCardProvEntry 5 }
adGenTa5kAtmLMCardResetDHCPRollingCounters OBJECT-TYPE
SYNTAX INTEGER { reset(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set will reset all dhcp card level rolling
counters"
::= { adGenTa5kAtmLMCardProvEntry 6 }
-- *********************************************************************************************************
-- Loop Timing Table
adGenTa5kAtmLMLoopTimingTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmLMLoopTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to set the Loop A and B timing used to provided timing
to the shelf"
::= { adGenTa5kAtmLMProvisioning 5 }
adGenTa5kAtmLMLoopTimingEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmLMLoopTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { adGenSlotInfoIndex }
::= { adGenTa5kAtmLMLoopTimingTable 1 }
AdGenTa5kAtmLMLoopTimingEntry ::=
SEQUENCE {
adGenTa5kAtmLMLoopTimingA INTEGER,
adGenTa5kAtmLMLoopTimingB INTEGER
}
adGenTa5kAtmLMLoopTimingA OBJECT-TYPE
SYNTAX INTEGER {
loop1(1),
loop2(2),
loop3(3),
loop4(4),
loop5(5),
loop6(6),
loop7(7),
loop8(8),
loop9(9),
loop10(10),
loop11(11),
loop12(12),
loop13(13),
loop14(14),
loop15(15),
loop16(16),
loop17(17),
loop18(18),
loop19(19),
loop20(20),
loop21(21),
loop22(22),
loop23(23),
loop24(24),
loop25(25),
loop26(26),
loop27(27),
loop28(28),
loop29(29),
loop30(30),
loop31(31),
loop32(32),
none(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LoopA Timing Source."
::= { adGenTa5kAtmLMLoopTimingEntry 1 }
adGenTa5kAtmLMLoopTimingB OBJECT-TYPE
SYNTAX INTEGER {
loop1(1),
loop2(2),
loop3(3),
loop4(4),
loop5(5),
loop6(6),
loop7(7),
loop8(8),
loop9(9),
loop10(10),
loop11(11),
loop12(12),
loop13(13),
loop14(14),
loop15(15),
loop16(16),
loop17(17),
loop18(18),
loop19(19),
loop20(20),
loop21(21),
loop22(22),
loop23(23),
loop24(24),
loop25(25),
loop26(26),
loop27(27),
loop28(28),
loop29(29),
loop30(30),
loop31(31),
loop32(32),
none(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LoopB Timing Source."
::= { adGenTa5kAtmLMLoopTimingEntry 2 }
-- *********************************************************************************************************
-- *********************************************************************************************************
adGenTa5kAtmPortStatsCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmPortStatsCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM Port Stats Current"
::= { adGenTa5kAtmLMPMStats 1 }
adGenTa5kAtmPortStatsCurrentEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmPortStatsCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex }
::= { adGenTa5kAtmPortStatsCurrentTable 1 }
AdGenTa5kAtmPortStatsCurrentEntry ::=
SEQUENCE {
adGenTa5kAtmPortStatsCurrentRxCells Counter32,
adGenTa5kAtmPortStatsCurrentRxClp1Cells Counter32,
adGenTa5kAtmPortStatsCurrentRxClp0Cells Counter32,
adGenTa5kAtmPortStatsCurrentRxOamCells Counter32,
adGenTa5kAtmPortStatsCurrentTxCells Counter32,
adGenTa5kAtmPortStatsCurrentTxClp1Cells Counter32,
adGenTa5kAtmPortStatsCurrentTxClp0Cells Counter32,
adGenTa5kAtmPortStatsCurrentTxOamCells Counter32,
adGenTa5kAtmPortStatsCurrentResetStats Integer32,
adGenTa5kAtmPortStatsCurrentRxCellsPercentUtil Gauge32,
adGenTa5kAtmPortStatsCurrentTxCellsPercentUtil Gauge32
}
adGenTa5kAtmPortStatsCurrentRxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for RX cells"
::= { adGenTa5kAtmPortStatsCurrentEntry 1 }
adGenTa5kAtmPortStatsCurrentRxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for RX CLP1 cells"
::= { adGenTa5kAtmPortStatsCurrentEntry 2 }
adGenTa5kAtmPortStatsCurrentRxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for RX CLP0 cells"
::= { adGenTa5kAtmPortStatsCurrentEntry 3 }
adGenTa5kAtmPortStatsCurrentRxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for RX OAM cells"
::= { adGenTa5kAtmPortStatsCurrentEntry 4 }
adGenTa5kAtmPortStatsCurrentTxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for TX cells"
::= { adGenTa5kAtmPortStatsCurrentEntry 5 }
adGenTa5kAtmPortStatsCurrentTxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for TX CLP1 cells"
::= { adGenTa5kAtmPortStatsCurrentEntry 6 }
adGenTa5kAtmPortStatsCurrentTxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for TX CLP0 cells"
::= { adGenTa5kAtmPortStatsCurrentEntry 7 }
adGenTa5kAtmPortStatsCurrentTxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for TX OAM cells"
::= { adGenTa5kAtmPortStatsCurrentEntry 8 }
adGenTa5kAtmPortStatsCurrentResetStats OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A Set will reset all stats on interface "
::= { adGenTa5kAtmPortStatsCurrentEntry 9 }
adGenTa5kAtmPortStatsCurrentRxCellsPercentUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current percentage Utilization on the Rx links
(Divide by hundred to get the actual percentage value). "
::= { adGenTa5kAtmPortStatsCurrentEntry 10 }
adGenTa5kAtmPortStatsCurrentTxCellsPercentUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current percentage Utilization on the Tx links
(Divide by hundred to get the actual percentage value). "
::= { adGenTa5kAtmPortStatsCurrentEntry 11 }
-- *********************************************************************************************************
adGenTa5kAtmPortStatsIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmPortStatsIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM Port Interval Stats"
::= { adGenTa5kAtmLMPMStats 2 }
adGenTa5kAtmPortStatsIntervalEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmPortStatsIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex, adGenTa5kAtmPortStatsIntervalIndex}
::= { adGenTa5kAtmPortStatsIntervalTable 1 }
AdGenTa5kAtmPortStatsIntervalEntry ::=
SEQUENCE {
adGenTa5kAtmPortStatsIntervalIndex Integer32,
adGenTa5kAtmPortStatsIntervalRxCells Counter32,
adGenTa5kAtmPortStatsIntervalRxClp1Cells Counter32,
adGenTa5kAtmPortStatsIntervalRxClp0Cells Counter32,
adGenTa5kAtmPortStatsIntervalRxOamCells Counter32,
adGenTa5kAtmPortStatsIntervalTxCells Counter32,
adGenTa5kAtmPortStatsIntervalTxClp1Cells Counter32,
adGenTa5kAtmPortStatsIntervalTxClp0Cells Counter32,
adGenTa5kAtmPortStatsIntervalTxOamCells Counter32,
adGenTa5kAtmPortStatsIntervalTimeStamp DisplayString,
adGenTa5kAtmPortStatsIntervalRxCellsPercentUtil Gauge32,
adGenTa5kAtmPortStatsIntervalTxCellsPercentUtil Gauge32
}
adGenTa5kAtmPortStatsIntervalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the 15-minute interval"
::= { adGenTa5kAtmPortStatsIntervalEntry 1 }
adGenTa5kAtmPortStatsIntervalRxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Cells in 15-minute interval"
::= { adGenTa5kAtmPortStatsIntervalEntry 2 }
adGenTa5kAtmPortStatsIntervalRxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Clp1 Cells in 15-minute interval"
::= { adGenTa5kAtmPortStatsIntervalEntry 3 }
adGenTa5kAtmPortStatsIntervalRxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Clp0 Cells in 15-minute interval"
::= { adGenTa5kAtmPortStatsIntervalEntry 4 }
adGenTa5kAtmPortStatsIntervalRxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx OAM Cells in 15-minute interval"
::= { adGenTa5kAtmPortStatsIntervalEntry 5 }
adGenTa5kAtmPortStatsIntervalTxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Cells in 15-minute interval"
::= { adGenTa5kAtmPortStatsIntervalEntry 6 }
adGenTa5kAtmPortStatsIntervalTxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Clp1 Cells in 15-minute interval"
::= { adGenTa5kAtmPortStatsIntervalEntry 7 }
adGenTa5kAtmPortStatsIntervalTxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Clp0 Cells in 15-minute interval"
::= { adGenTa5kAtmPortStatsIntervalEntry 8 }
adGenTa5kAtmPortStatsIntervalTxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx OAM Cells in 15-minute interval"
::= { adGenTa5kAtmPortStatsIntervalEntry 9 }
adGenTa5kAtmPortStatsIntervalTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp of the 15-minute interval"
::= { adGenTa5kAtmPortStatsIntervalEntry 10 }
adGenTa5kAtmPortStatsIntervalRxCellsPercentUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage Utilization for the 15 min interval on the Rx links
(Divide by hundred to get the actual percentage value). "
::= { adGenTa5kAtmPortStatsIntervalEntry 11 }
adGenTa5kAtmPortStatsIntervalTxCellsPercentUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage Utilization for the 15 min interval on the Tx links
(Divide by hundred to get the actual percentage value). "
::= { adGenTa5kAtmPortStatsIntervalEntry 12 }
-- *********************************************************************************************************
adGenTa5kAtmPortStats24hrCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmPortStats24hrCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM Port 24hr Current Stats"
::= { adGenTa5kAtmLMPMStats 3 }
adGenTa5kAtmPortStats24hrCurrentEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmPortStats24hrCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex}
::= { adGenTa5kAtmPortStats24hrCurrentTable 1 }
AdGenTa5kAtmPortStats24hrCurrentEntry ::=
SEQUENCE {
adGenTa5kAtmPortStats24hrCurrentRxCells Counter32,
adGenTa5kAtmPortStats24hrCurrentRxClp1Cells Counter32,
adGenTa5kAtmPortStats24hrCurrentRxClp0Cells Counter32,
adGenTa5kAtmPortStats24hrCurrentRxOamCells Counter32,
adGenTa5kAtmPortStats24hrCurrentTxCells Counter32,
adGenTa5kAtmPortStats24hrCurrentTxClp1Cells Counter32,
adGenTa5kAtmPortStats24hrCurrentTxClp0Cells Counter32,
adGenTa5kAtmPortStats24hrCurrentTxOamCells Counter32
}
adGenTa5kAtmPortStats24hrCurrentRxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Cells in the current 24 hour period"
::= { adGenTa5kAtmPortStats24hrCurrentEntry 1 }
adGenTa5kAtmPortStats24hrCurrentRxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Clp1 Cells in the current 24 hour period"
::= { adGenTa5kAtmPortStats24hrCurrentEntry 2 }
adGenTa5kAtmPortStats24hrCurrentRxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Clp0 Cells the current 24 hour period"
::= { adGenTa5kAtmPortStats24hrCurrentEntry 3 }
adGenTa5kAtmPortStats24hrCurrentRxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx OAM Cells in the current 24 hour period"
::= { adGenTa5kAtmPortStats24hrCurrentEntry 4 }
adGenTa5kAtmPortStats24hrCurrentTxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Cells in the current 24 hour period"
::= { adGenTa5kAtmPortStats24hrCurrentEntry 5 }
adGenTa5kAtmPortStats24hrCurrentTxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Clp1 Cells in the current 24 hour period"
::= { adGenTa5kAtmPortStats24hrCurrentEntry 6 }
adGenTa5kAtmPortStats24hrCurrentTxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Clp0 Cells in the current 24 hour period"
::= { adGenTa5kAtmPortStats24hrCurrentEntry 7 }
adGenTa5kAtmPortStats24hrCurrentTxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx OAM Cells in the current 24 hour period"
::= { adGenTa5kAtmPortStats24hrCurrentEntry 8 }
-- *********************************************************************************************************
adGenTa5kAtmPortStats24hrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmPortStats24hrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM Port 24hr Stats"
::= { adGenTa5kAtmLMPMStats 4 }
adGenTa5kAtmPortStats24hrEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmPortStats24hrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex, adGenTa5kAtmPortStats24hrIndex}
::= { adGenTa5kAtmPortStats24hrTable 1 }
AdGenTa5kAtmPortStats24hrEntry ::=
SEQUENCE {
adGenTa5kAtmPortStats24hrIndex Integer32,
adGenTa5kAtmPortStats24hrRxCells Counter32,
adGenTa5kAtmPortStats24hrRxClp1Cells Counter32,
adGenTa5kAtmPortStats24hrRxClp0Cells Counter32,
adGenTa5kAtmPortStats24hrRxOamCells Counter32,
adGenTa5kAtmPortStats24hrTxCells Counter32,
adGenTa5kAtmPortStats24hrTxClp1Cells Counter32,
adGenTa5kAtmPortStats24hrTxClp0Cells Counter32,
adGenTa5kAtmPortStats24hrTxOamCells Counter32,
adGenTa5kAtmPortStats24hrTimeStamp DisplayString
}
adGenTa5kAtmPortStats24hrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the 24 hour period"
::= { adGenTa5kAtmPortStats24hrEntry 1 }
adGenTa5kAtmPortStats24hrRxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Cells in a 24 hour period"
::= { adGenTa5kAtmPortStats24hrEntry 2 }
adGenTa5kAtmPortStats24hrRxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Clp1 Cells in a 24 hour period"
::= { adGenTa5kAtmPortStats24hrEntry 3 }
adGenTa5kAtmPortStats24hrRxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx Clp0 Cells a 24 hour period"
::= { adGenTa5kAtmPortStats24hrEntry 4 }
adGenTa5kAtmPortStats24hrRxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rx OAM Cells in a 24 hour period"
::= { adGenTa5kAtmPortStats24hrEntry 5 }
adGenTa5kAtmPortStats24hrTxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Cells in a 24 hour period"
::= { adGenTa5kAtmPortStats24hrEntry 6 }
adGenTa5kAtmPortStats24hrTxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Clp1 Cells in a 24 hour period"
::= { adGenTa5kAtmPortStats24hrEntry 7 }
adGenTa5kAtmPortStats24hrTxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Clp0 Cells in a 24 hour period"
::= { adGenTa5kAtmPortStats24hrEntry 8 }
adGenTa5kAtmPortStats24hrTxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx OAM Cells in a 24 hour period"
::= { adGenTa5kAtmPortStats24hrEntry 9 }
adGenTa5kAtmPortStats24hrTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp of 24 hour period (Date)"
::= { adGenTa5kAtmPortStats24hrEntry 10 }
-- *********************************************************************************************************
adGenTa5kAtmVclStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmVclStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM Vcl Stats"
::= { adGenTa5kAtmLMPMStats 5 }
adGenTa5kAtmVclStatsEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmVclStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex, atmVclVpi, atmVclVci}
::= { adGenTa5kAtmVclStatsTable 1 }
AdGenTa5kAtmVclStatsEntry ::=
SEQUENCE {
adGenTa5kAtmVclStatsResetPM Integer32,
adGenTa5kAtmVclStatsRxAIS INTEGER,
adGenTa5kAtmVclStatsRxRDI INTEGER,
adGenTa5kAtmVclStatsGenAISRDI TruthValue,
adGenTa5kAtmVclStatsOamTxLbReqs Integer32,
adGenTa5kAtmVclStatsOamRxLbReqs Integer32,
adGenTa5kAtmVclStatsOamTxLbResps Integer32,
adGenTa5kAtmVclStatsOamRxLbResps Integer32,
adGenTa5kAtmVclStatsOamLbTimeouts Integer32,
adGenTa5kAtmVclStatsOamLbLastResult INTEGER,
adGenTa5kAtmVclStatsConnectionInfo DisplayString
}
adGenTa5kAtmVclStatsResetPM OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset Stats"
::= { adGenTa5kAtmVclStatsEntry 1 }
adGenTa5kAtmVclStatsRxAIS OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2),
na(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True - indicates Rx AIS"
::= { adGenTa5kAtmVclStatsEntry 2 }
adGenTa5kAtmVclStatsRxRDI OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2),
na(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True - indicates Rx RDI"
::= { adGenTa5kAtmVclStatsEntry 3 }
adGenTa5kAtmVclStatsGenAISRDI OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True - indicates Vcl is generating AIS/RDI"
::= { adGenTa5kAtmVclStatsEntry 4 }
adGenTa5kAtmVclStatsOamTxLbReqs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted F5 OAM Loopback Requests"
::= { adGenTa5kAtmVclStatsEntry 5 }
adGenTa5kAtmVclStatsOamRxLbReqs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received F5 OAM Loopback Requests"
::= { adGenTa5kAtmVclStatsEntry 6 }
adGenTa5kAtmVclStatsOamTxLbResps OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted F5 OAM Loopback Responses"
::= { adGenTa5kAtmVclStatsEntry 7 }
adGenTa5kAtmVclStatsOamRxLbResps OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received F5 OAM Loopback Responses"
::= { adGenTa5kAtmVclStatsEntry 8 }
adGenTa5kAtmVclStatsOamLbTimeouts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted F5 OAM Loopback Requests which timed out with no response"
::= { adGenTa5kAtmVclStatsEntry 9 }
adGenTa5kAtmVclStatsOamLbLastResult OBJECT-TYPE
SYNTAX INTEGER {
noneSent(0),
cellOutstanding(1),
responseReceived(2),
timedOut(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result of the last loopback request"
::= { adGenTa5kAtmVclStatsEntry 10 }
adGenTa5kAtmVclStatsConnectionInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCL connection information"
::= { adGenTa5kAtmVclStatsEntry 11 }
-- *********************************************************************************************************
adGenTa5kAtmVplStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmVplStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM Vpl Stats"
::= { adGenTa5kAtmLMPMStats 6 }
adGenTa5kAtmVplStatsEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmVplStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex, atmVplVpi}
::= { adGenTa5kAtmVplStatsTable 1 }
AdGenTa5kAtmVplStatsEntry ::=
SEQUENCE {
adGenTa5kAtmVplStatsResetPM Integer32,
adGenTa5kAtmVplStatsRxAIS INTEGER,
adGenTa5kAtmVplStatsRxRDI INTEGER,
adGenTa5kAtmVplStatsGenAISRDI TruthValue,
adGenTa5kAtmVplStatsOamTxLbReqs Integer32,
adGenTa5kAtmVplStatsOamRxLbReqs Integer32,
adGenTa5kAtmVplStatsOamTxLbResps Integer32,
adGenTa5kAtmVplStatsOamRxLbResps Integer32,
adGenTa5kAtmVplStatsOamLbTimeouts Integer32,
adGenTa5kAtmVplStatsOamLbLastResult INTEGER,
adGenTa5kAtmVplStatsAal5InPkts Counter32,
adGenTa5kAtmVplStatsAal5OutPkts Counter32,
adGenTa5kAtmVplStatsAal5InOctets Counter32,
adGenTa5kAtmVplStatsAal5OutOctets Counter32,
adGenTa5kAtmVplStatsConnectionInfo DisplayString
}
adGenTa5kAtmVplStatsResetPM OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset Stats"
::= { adGenTa5kAtmVplStatsEntry 1 }
adGenTa5kAtmVplStatsRxAIS OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2),
na(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True - indicates Rx AIS"
::= { adGenTa5kAtmVplStatsEntry 2 }
adGenTa5kAtmVplStatsRxRDI OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2),
na(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True - indicates Rx RDI"
::= { adGenTa5kAtmVplStatsEntry 3 }
adGenTa5kAtmVplStatsGenAISRDI OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True - indicates Vpl is generating AIS/RDI"
::= { adGenTa5kAtmVplStatsEntry 4 }
adGenTa5kAtmVplStatsOamTxLbReqs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted F4 OAM Loopback Requests"
::= { adGenTa5kAtmVplStatsEntry 5 }
adGenTa5kAtmVplStatsOamRxLbReqs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received F4 OAM Loopback Requests"
::= { adGenTa5kAtmVplStatsEntry 6 }
adGenTa5kAtmVplStatsOamTxLbResps OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted F4 OAM Loopback Responses"
::= { adGenTa5kAtmVplStatsEntry 7 }
adGenTa5kAtmVplStatsOamRxLbResps OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received F4 OAM Loopback Responses"
::= { adGenTa5kAtmVplStatsEntry 8 }
adGenTa5kAtmVplStatsOamLbTimeouts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted F4 OAM Loopback Requests which timed out with no response"
::= { adGenTa5kAtmVplStatsEntry 9 }
adGenTa5kAtmVplStatsOamLbLastResult OBJECT-TYPE
SYNTAX INTEGER {
noneSent(0),
cellOutstanding(1),
responseReceived(2),
timedOut(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result of the last loopback request"
::= { adGenTa5kAtmVplStatsEntry 10 }
adGenTa5kAtmVplStatsAal5InPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of AAL5 CPCS PDUs received on the AAL5
VPC at the interface identified by the ifIndex."
::= { adGenTa5kAtmVplStatsEntry 11 }
adGenTa5kAtmVplStatsAal5OutPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of AAL5 CPCS PDUs transmitted on the
AAL5 VPC at the interface identified by the
ifIndex."
::= { adGenTa5kAtmVplStatsEntry 12 }
adGenTa5kAtmVplStatsAal5InOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in AAL5 CPCS PDUs
received on the AAL5 VPC at the interface
identified by the ifIndex."
::= { adGenTa5kAtmVplStatsEntry 13 }
adGenTa5kAtmVplStatsAal5OutOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in AAL5 CPCS PDUs
transmitted on the AAL5 VPC at the interface
identified by the ifIndex."
::= { adGenTa5kAtmVplStatsEntry 14 }
adGenTa5kAtmVplStatsConnectionInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPL connection information"
::= { adGenTa5kAtmVplStatsEntry 15 }
-- *********************************************************************************************************
adGenTa5kAtmPortStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmPortStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM Port Stats Free-Rolling Counters"
::= { adGenTa5kAtmLMPMStats 7 }
adGenTa5kAtmPortStatsEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmPortStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex }
::= { adGenTa5kAtmPortStatsTable 1 }
AdGenTa5kAtmPortStatsEntry ::=
SEQUENCE {
adGenTa5kAtmPortStatsRxCells Counter32,
adGenTa5kAtmPortStatsRxClp1Cells Counter32,
adGenTa5kAtmPortStatsRxClp0Cells Counter32,
adGenTa5kAtmPortStatsRxOamCells Counter32,
adGenTa5kAtmPortStatsTxCells Counter32,
adGenTa5kAtmPortStatsTxClp1Cells Counter32,
adGenTa5kAtmPortStatsTxClp0Cells Counter32,
adGenTa5kAtmPortStatsTxOamCells Counter32,
adGenTa5kAtmPortStatsResetStats INTEGER,
adGenTa5kAtmPortStatsCellDelineation TruthValue
}
adGenTa5kAtmPortStatsRxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for RX cells"
::= { adGenTa5kAtmPortStatsEntry 1 }
adGenTa5kAtmPortStatsRxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for RX CLP1 cells"
::= { adGenTa5kAtmPortStatsEntry 2 }
adGenTa5kAtmPortStatsRxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for RX CLP0 cells"
::= { adGenTa5kAtmPortStatsEntry 3 }
adGenTa5kAtmPortStatsRxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for RX OAM cells"
::= { adGenTa5kAtmPortStatsEntry 4 }
adGenTa5kAtmPortStatsTxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for TX cells"
::= { adGenTa5kAtmPortStatsEntry 5 }
adGenTa5kAtmPortStatsTxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for TX CLP1 cells"
::= { adGenTa5kAtmPortStatsEntry 6 }
adGenTa5kAtmPortStatsTxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for TX CLP0 cells"
::= { adGenTa5kAtmPortStatsEntry 7 }
adGenTa5kAtmPortStatsTxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for TX OAM cells"
::= { adGenTa5kAtmPortStatsEntry 8 }
adGenTa5kAtmPortStatsResetStats OBJECT-TYPE
SYNTAX INTEGER { reset(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A Set will reset all rolling
counters on interface "
::= { adGenTa5kAtmPortStatsEntry 9 }
adGenTa5kAtmPortStatsCellDelineation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns cell delineation status:
true = cell delineation,
false = out of cell delineation"
::= { adGenTa5kAtmPortStatsEntry 10 }
-- *********************************************************************************************************
adGenTa5kAtmDhcpStatsCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmDhcpStatsCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Relay Agent Stats Current"
::= { adGenTa5kAtmLMPMStats 8 }
adGenTa5kAtmDhcpStatsCurrentEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmDhcpStatsCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex }
::= { adGenTa5kAtmDhcpStatsCurrentTable 1 }
AdGenTa5kAtmDhcpStatsCurrentEntry ::=
SEQUENCE {
adGenTa5kAtmDhcpStatsCurrentUpstreamFwdPktCnt Counter32,
adGenTa5kAtmDhcpStatsCurrentDownstreamFwdPktCnt Counter32,
adGenTa5kAtmDhcpStatsCurrentUpstreamDiscardPktCnt Counter32,
adGenTa5kAtmDhcpStatsCurrentDownstreamDiscardPktCnt Counter32
}
adGenTa5kAtmDhcpStatsCurrentUpstreamFwdPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for upstream valid DHCP messages processed"
::= { adGenTa5kAtmDhcpStatsCurrentEntry 1 }
adGenTa5kAtmDhcpStatsCurrentDownstreamFwdPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for downstream valid DHCP messages processed"
::= { adGenTa5kAtmDhcpStatsCurrentEntry 2 }
adGenTa5kAtmDhcpStatsCurrentUpstreamDiscardPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for upstream dropped invalid or malformed DHCP messages"
::= { adGenTa5kAtmDhcpStatsCurrentEntry 3 }
adGenTa5kAtmDhcpStatsCurrentDownstreamDiscardPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for downstream dropped invalid or malformed DHCP messages"
::= { adGenTa5kAtmDhcpStatsCurrentEntry 4 }
-- *********************************************************************************************************
adGenTa5kAtmDhcpStatsIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmDhcpStatsIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Relay Agent Interval Stats"
::= { adGenTa5kAtmLMPMStats 9 }
adGenTa5kAtmDhcpStatsIntervalEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmDhcpStatsIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex, adGenTa5kAtmDhcpStatsIntervalIndex}
::= { adGenTa5kAtmDhcpStatsIntervalTable 1 }
AdGenTa5kAtmDhcpStatsIntervalEntry ::=
SEQUENCE {
adGenTa5kAtmDhcpStatsIntervalIndex Integer32,
adGenTa5kAtmDhcpStatsIntervalUpstreamFwdPktCnt Counter32,
adGenTa5kAtmDhcpStatsIntervalDownstreamFwdPktCnt Counter32,
adGenTa5kAtmDhcpStatsIntervalUpstreamDiscardPktCnt Counter32,
adGenTa5kAtmDhcpStatsIntervalDownstreamDiscardPktCnt Counter32,
adGenTa5kAtmDhcpStatsIntervalTimeStamp DisplayString
}
adGenTa5kAtmDhcpStatsIntervalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the 15-minute interval"
::= { adGenTa5kAtmDhcpStatsIntervalEntry 1 }
adGenTa5kAtmDhcpStatsIntervalUpstreamFwdPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upstream valid DHCP messages processed in 15-minute interval"
::= { adGenTa5kAtmDhcpStatsIntervalEntry 2 }
adGenTa5kAtmDhcpStatsIntervalDownstreamFwdPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Downstream valid DHCP messages processed in 15-minute interval"
::= { adGenTa5kAtmDhcpStatsIntervalEntry 3 }
adGenTa5kAtmDhcpStatsIntervalUpstreamDiscardPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upstream dropped invalid or malformed DHCP messages in 15-minute interval"
::= { adGenTa5kAtmDhcpStatsIntervalEntry 4 }
adGenTa5kAtmDhcpStatsIntervalDownstreamDiscardPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Downstream dropped invalid or malformed DHCP messages in 15-minute interval"
::= { adGenTa5kAtmDhcpStatsIntervalEntry 5 }
adGenTa5kAtmDhcpStatsIntervalTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp of the 15-minute interval"
::= { adGenTa5kAtmDhcpStatsIntervalEntry 6 }
-- *********************************************************************************************************
adGenTa5kAtmDhcpStats24hrCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmDhcpStats24hrCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Relay Agent 24hr Current Stats"
::= { adGenTa5kAtmLMPMStats 10 }
adGenTa5kAtmDhcpStats24hrCurrentEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmDhcpStats24hrCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex}
::= { adGenTa5kAtmDhcpStats24hrCurrentTable 1 }
AdGenTa5kAtmDhcpStats24hrCurrentEntry ::=
SEQUENCE {
adGenTa5kAtmDhcpStats24hrCurrentUpstreamFwdPktCnt Counter32,
adGenTa5kAtmDhcpStats24hrCurrentDownstreamFwdPktCnt Counter32,
adGenTa5kAtmDhcpStats24hrCurrentUpstreamDiscardPktCnt Counter32,
adGenTa5kAtmDhcpStats24hrCurrentDownstreamDiscardPktCnt Counter32
}
adGenTa5kAtmDhcpStats24hrCurrentUpstreamFwdPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upstream valid DHCP messages processed in the current 24 hour period"
::= { adGenTa5kAtmDhcpStats24hrCurrentEntry 1 }
adGenTa5kAtmDhcpStats24hrCurrentDownstreamFwdPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Downstream valid DHCP messages processed in the current 24 hour period"
::= { adGenTa5kAtmDhcpStats24hrCurrentEntry 2 }
adGenTa5kAtmDhcpStats24hrCurrentUpstreamDiscardPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upstream dropped invalid or malformed DHCP messages in the current 24 hour period"
::= { adGenTa5kAtmDhcpStats24hrCurrentEntry 3 }
adGenTa5kAtmDhcpStats24hrCurrentDownstreamDiscardPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Downstream dropped invalid or malformed DHCP messages in the current 24 hour period"
::= { adGenTa5kAtmDhcpStats24hrCurrentEntry 4 }
-- *********************************************************************************************************
adGenTa5kAtmDhcpStats24hrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmDhcpStats24hrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Relay Agent 24hr Interval Stats"
::= { adGenTa5kAtmLMPMStats 11 }
adGenTa5kAtmDhcpStats24hrEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmDhcpStats24hrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex, adGenTa5kAtmDhcpStats24hrIndex}
::= { adGenTa5kAtmDhcpStats24hrTable 1 }
AdGenTa5kAtmDhcpStats24hrEntry ::=
SEQUENCE {
adGenTa5kAtmDhcpStats24hrIndex Integer32,
adGenTa5kAtmDhcpStats24hrUpstreamFwdPktCnt Counter32,
adGenTa5kAtmDhcpStats24hrDownstreamFwdPktCnt Counter32,
adGenTa5kAtmDhcpStats24hrUpstreamDiscardPktCnt Counter32,
adGenTa5kAtmDhcpStats24hrDownstreamDiscardPktCnt Counter32,
adGenTa5kAtmDhcpStats24hrTimeStamp DisplayString
}
adGenTa5kAtmDhcpStats24hrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the 24 hour period"
::= { adGenTa5kAtmDhcpStats24hrEntry 1 }
adGenTa5kAtmDhcpStats24hrUpstreamFwdPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upstream valid DHCP messages processed in a 24 hour period"
::= { adGenTa5kAtmDhcpStats24hrEntry 2 }
adGenTa5kAtmDhcpStats24hrDownstreamFwdPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Downstream valid DHCP messages processed in a 24 hour period"
::= { adGenTa5kAtmDhcpStats24hrEntry 3 }
adGenTa5kAtmDhcpStats24hrUpstreamDiscardPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upstream dropped invalid or malformed DHCP messages in a 24 hour period"
::= { adGenTa5kAtmDhcpStats24hrEntry 4 }
adGenTa5kAtmDhcpStats24hrDownstreamDiscardPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Downstream dropped invalid or malformed DHCP messages in a 24 hour period"
::= { adGenTa5kAtmDhcpStats24hrEntry 5 }
adGenTa5kAtmDhcpStats24hrTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp of 24 hour period (Date)"
::= { adGenTa5kAtmDhcpStats24hrEntry 6 }
-- *********************************************************************************************************
adGenTa5kAtmDhcpStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmDhcpStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Relay Agent Stats Free-Rolling Counters"
::= { adGenTa5kAtmLMPMStats 12 }
adGenTa5kAtmDhcpStatsEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmDhcpStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex }
::= { adGenTa5kAtmDhcpStatsTable 1 }
AdGenTa5kAtmDhcpStatsEntry ::=
SEQUENCE {
adGenTa5kAtmDhcpStatsUpstreamFwdPktCnt Counter32,
adGenTa5kAtmDhcpStatsDownstreamFwdPktCnt Counter32,
adGenTa5kAtmDhcpStatsUpstreamDiscardPktCnt Counter32,
adGenTa5kAtmDhcpStatsDownstreamDiscardPktCnt Counter32
}
adGenTa5kAtmDhcpStatsUpstreamFwdPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for upstream valid DHCP messages processed"
::= { adGenTa5kAtmDhcpStatsEntry 1 }
adGenTa5kAtmDhcpStatsDownstreamFwdPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for downstream valid DHCP messages processed"
::= { adGenTa5kAtmDhcpStatsEntry 2 }
adGenTa5kAtmDhcpStatsUpstreamDiscardPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for upstream dropped invalid or malformed DHCP messages"
::= { adGenTa5kAtmDhcpStatsEntry 3 }
adGenTa5kAtmDhcpStatsDownstreamDiscardPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for downstream dropped invalid or malformed DHCP messages"
::= { adGenTa5kAtmDhcpStatsEntry 4 }
-- *********************************************************************************************************
adGenTa5kAtmDhcpPerCardStatsCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmDhcpPerCardStatsCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Relay Agent Card Level Stats Current"
::= { adGenTa5kAtmLMPMStats 13 }
adGenTa5kAtmDhcpPerCardStatsCurrentEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmDhcpPerCardStatsCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { adGenSlotInfoIndex }
::= { adGenTa5kAtmDhcpPerCardStatsCurrentTable 1 }
AdGenTa5kAtmDhcpPerCardStatsCurrentEntry ::=
SEQUENCE {
adGenTa5kAtmDhcpPerCardStatsCurrentUpstreamDroppedPktCnt Counter32,
adGenTa5kAtmDhcpPerCardStatsCurrentDownstreamDroppedPktCnt Counter32
}
adGenTa5kAtmDhcpPerCardStatsCurrentUpstreamDroppedPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for upstream dropped messages due to policing of DHCP messages"
::= { adGenTa5kAtmDhcpPerCardStatsCurrentEntry 1 }
adGenTa5kAtmDhcpPerCardStatsCurrentDownstreamDroppedPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current counter for downstream dropped messages due to policing of DHCP messages"
::= { adGenTa5kAtmDhcpPerCardStatsCurrentEntry 2 }
-- *********************************************************************************************************
adGenTa5kAtmDhcpPerCardStatsIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmDhcpPerCardStatsIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Relay Agent Card Level Interval Stats"
::= { adGenTa5kAtmLMPMStats 14 }
adGenTa5kAtmDhcpPerCardStatsIntervalEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmDhcpPerCardStatsIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { adGenSlotInfoIndex, adGenTa5kAtmDhcpPerCardStatsIntervalIndex}
::= { adGenTa5kAtmDhcpPerCardStatsIntervalTable 1 }
AdGenTa5kAtmDhcpPerCardStatsIntervalEntry ::=
SEQUENCE {
adGenTa5kAtmDhcpPerCardStatsIntervalIndex Integer32,
adGenTa5kAtmDhcpPerCardStatsIntervalUpstreamDroppedPktCnt Counter32,
adGenTa5kAtmDhcpPerCardStatsIntervalDownstreamDroppedPktCnt Counter32,
adGenTa5kAtmDhcpPerCardStatsIntervalTimeStamp DisplayString
}
adGenTa5kAtmDhcpPerCardStatsIntervalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the 15-minute interval"
::= { adGenTa5kAtmDhcpPerCardStatsIntervalEntry 1 }
adGenTa5kAtmDhcpPerCardStatsIntervalUpstreamDroppedPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upstream dropped messages due to policing of DHCP messages in 15-minute interval"
::= { adGenTa5kAtmDhcpPerCardStatsIntervalEntry 2 }
adGenTa5kAtmDhcpPerCardStatsIntervalDownstreamDroppedPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Downstream dropped messages due to policing of DHCP messages in 15-minute interval"
::= { adGenTa5kAtmDhcpPerCardStatsIntervalEntry 3 }
adGenTa5kAtmDhcpPerCardStatsIntervalTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp of the 15-minute interval"
::= { adGenTa5kAtmDhcpPerCardStatsIntervalEntry 4 }
-- *********************************************************************************************************
adGenTa5kAtmDhcpPerCardStats24hrCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmDhcpPerCardStats24hrCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Relay Agent Card Level 24hr Current Stats"
::= { adGenTa5kAtmLMPMStats 15 }
adGenTa5kAtmDhcpPerCardStats24hrCurrentEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmDhcpPerCardStats24hrCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { adGenSlotInfoIndex }
::= { adGenTa5kAtmDhcpPerCardStats24hrCurrentTable 1 }
AdGenTa5kAtmDhcpPerCardStats24hrCurrentEntry ::=
SEQUENCE {
adGenTa5kAtmDhcpPerCardStats24hrCurrentUpstreamDroppedPktCnt Counter32,
adGenTa5kAtmDhcpPerCardStats24hrCurrentDownstreamDroppedPktCnt Counter32
}
adGenTa5kAtmDhcpPerCardStats24hrCurrentUpstreamDroppedPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upstream dropped messages due to policing of DHCP messages in the current 24 hour period"
::= { adGenTa5kAtmDhcpPerCardStats24hrCurrentEntry 1 }
adGenTa5kAtmDhcpPerCardStats24hrCurrentDownstreamDroppedPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Downstream dropped messages due to policing of DHCP messages in the current 24 hour period"
::= { adGenTa5kAtmDhcpPerCardStats24hrCurrentEntry 2 }
-- *********************************************************************************************************
adGenTa5kAtmDhcpPerCardStats24hrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmDhcpPerCardStats24hrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Relay Agent Card Level 24hr Interval Stats"
::= { adGenTa5kAtmLMPMStats 16 }
adGenTa5kAtmDhcpPerCardStats24hrEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmDhcpPerCardStats24hrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { adGenSlotInfoIndex, adGenTa5kAtmDhcpPerCardStats24hrIndex}
::= { adGenTa5kAtmDhcpPerCardStats24hrTable 1 }
AdGenTa5kAtmDhcpPerCardStats24hrEntry ::=
SEQUENCE {
adGenTa5kAtmDhcpPerCardStats24hrIndex Integer32,
adGenTa5kAtmDhcpPerCardStats24hrUpstreamDroppedPktCnt Counter32,
adGenTa5kAtmDhcpPerCardStats24hrDownstreamDroppedPktCnt Counter32,
adGenTa5kAtmDhcpPerCardStats24hrTimeStamp DisplayString
}
adGenTa5kAtmDhcpPerCardStats24hrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the 24 hour period"
::= { adGenTa5kAtmDhcpPerCardStats24hrEntry 1 }
adGenTa5kAtmDhcpPerCardStats24hrUpstreamDroppedPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upstream dropped messages due to policing of DHCP messages in a 24 hour period"
::= { adGenTa5kAtmDhcpPerCardStats24hrEntry 2 }
adGenTa5kAtmDhcpPerCardStats24hrDownstreamDroppedPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Downstream dropped messages due to policing of DHCP messages in a 24 hour period"
::= { adGenTa5kAtmDhcpPerCardStats24hrEntry 3 }
adGenTa5kAtmDhcpPerCardStats24hrTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp of 24 hour period (Date)"
::= { adGenTa5kAtmDhcpPerCardStats24hrEntry 4 }
-- *********************************************************************************************************
adGenTa5kAtmDhcpPerCardStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmDhcpPerCardStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Relay Agent Card Level Stats Free-Rolling Counters"
::= { adGenTa5kAtmLMPMStats 17 }
adGenTa5kAtmDhcpPerCardStatsEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmDhcpPerCardStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { adGenSlotInfoIndex }
::= { adGenTa5kAtmDhcpPerCardStatsTable 1 }
AdGenTa5kAtmDhcpPerCardStatsEntry ::=
SEQUENCE {
adGenTa5kAtmDhcpPerCardStatsUpstreamDroppedPktCnt Counter32,
adGenTa5kAtmDhcpPerCardStatsDownstreamDroppedPktCnt Counter32
}
adGenTa5kAtmDhcpPerCardStatsUpstreamDroppedPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for upstream dropped messages due to policing of DHCP messages"
::= { adGenTa5kAtmDhcpPerCardStatsEntry 1 }
adGenTa5kAtmDhcpPerCardStatsDownstreamDroppedPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rolling counter for downstream dropped messages due to policing of DHCP messages"
::= { adGenTa5kAtmDhcpPerCardStatsEntry 2 }
-- *********************************************************************************************************
-- *********************************************************************************************************
adGenTa5kAtmLMErrorVcTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmLMErrorVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing each ATM interface's last Interworked VP Cross Connect Errored VC"
::= { adGenTa5kAtmLMVpStatus 1 }
adGenTa5kAtmLMErrorVcEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmLMErrorVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex }
::= { adGenTa5kAtmLMErrorVcTable 1 }
AdGenTa5kAtmLMErrorVcEntry ::=
SEQUENCE {
adGenTa5kAtmLMRecentErrorVC DisplayString,
adGenTa5kAtmLMRecentErrorVCClear INTEGER
}
adGenTa5kAtmLMRecentErrorVC OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"String that represents the most recent Errored VC on this ATM interface"
::= { adGenTa5kAtmLMErrorVcEntry 1 }
adGenTa5kAtmLMRecentErrorVCClear OBJECT-TYPE
SYNTAX INTEGER{ reset(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"String that represents the most recent Errored VC on this ATM interface"
::= { adGenTa5kAtmLMErrorVcEntry 2 }
-- *********************************************************************************************************
adGenTa5kAtmVpStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenTa5kAtmVpStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM Vpl Status"
::= { adGenTa5kAtmLMVpStatus 2 }
adGenTa5kAtmVpStatusEntry OBJECT-TYPE
SYNTAX AdGenTa5kAtmVpStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table Entry"
INDEX { ifIndex, atmVclVpi, atmVclVci}
::= { adGenTa5kAtmVpStatusTable 1 }
AdGenTa5kAtmVpStatusEntry ::=
SEQUENCE {
adGenTa5kAtmVpStatusVc INTEGER,
adGenTa5kAtmVpStatusVcEncaps INTEGER,
adGenTa5kAtmVpStatusVcDelete INTEGER
}
adGenTa5kAtmVpStatusVc OBJECT-TYPE
SYNTAX INTEGER {
exists(1),
missing(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns exists(1) for a VC that are currently active on an Interworked VP"
::= { adGenTa5kAtmVpStatusEntry 1 }
adGenTa5kAtmVpStatusVcEncaps OBJECT-TYPE
SYNTAX INTEGER {
vcmuxrouted(1),
vcmuxbridged8023(2),
vcmuxbridged8025(3),
vcmuxbridged8026(4),
lanemul8023(5),
lanemul8025(6),
llcencap(7),
framerelay(8),
other(9),
unknown(10),
vcmuxpppoapppoeiw(11),
llcpppoapppoeiw(12),
llcautodiscover(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { adGenTa5kAtmVpStatusEntry 2 }
adGenTa5kAtmVpStatusVcDelete OBJECT-TYPE
SYNTAX INTEGER { delete(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Gets will always return 1, Sets 1 will delete the Vc if it exist"
::= { adGenTa5kAtmVpStatusEntry 3 }
-- *********************************************************************************************************
adGenTa5kAtmLMUnlearnableVCL NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
ifIndex,
adGenTa5kAtmLMRecentErrorVC
}
STATUS current
DESCRIPTION
"TA 5000 ATM Line Module Unlearnable VCL"
--#TYPE "Unlearnable VCL"
--#SUMMARY "The ATM Cell Processor Discovered a VC that it cannot learn"
--#SUMMARY "set at shelf: %s, slot: %d"
--#ARGUMENTS { 1, 2 }
--#SEVERITY INFO
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { adGenTa5kAtmLMAlarm 1 }