ADTRAN-GENTSCAN-MIB
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
-- ADTRAN Proprietary and Confidential
|
|
--
|
|
-- TITLE: The ADTRAN Generic TSCAN MIB
|
|
-- PRODUCTS: 1181413Lx
|
|
-- VERSION: 1.0
|
|
-- AUTHOR: Brian Slack
|
|
-- DATE: 03/06/10
|
|
--
|
|
-- This MIB defines the TSCAN management information for the 3rd gen or higher Single Port
|
|
-- H4TUC access module for a Total Access 3000 shelf.
|
|
|
|
--
|
|
-- Contact Information:
|
|
-- CND Tech Support
|
|
-- Postal: ADTRAN, Inc.
|
|
-- 901 Explorer Blvd.
|
|
-- Huntsville, AL 35806
|
|
-- Tel: +1 800 726-8663
|
|
-- Fax: +1 256 963 6217
|
|
-- E-mail: support@adtran.com
|
|
--
|
|
-- HISTORY:
|
|
-- 03/06/10 bcs First edition.
|
|
-- 03/06/18 bcs Added adGenTSCANLS1 and adGenTSCANLS2. Changed the number of block used
|
|
-- to send the TSCAN data. Modified the descriptions and names.
|
|
-- 03/06/20 bcs Added idle as a return value to adGenTSCANTscanDataStatus. Corrected date
|
|
-- structure for the previous history item.
|
|
-- 04/03/11 kle Changed the read-write attributes on all items except
|
|
-- adGenTSCANAccumTscanData to read-only.
|
|
-- 07/10/02 jlb Converted to SNMPv2
|
|
-- 09/08/03 twc Added adGenTSCANLastTime and adGenTSCANRepeaterIndex
|
|
-- 11/06/09 crh Added extra blocks of bad taps for extended reach TSCAN
|
|
-- 11/19/09 crh Added adGenTSCANHybridConfig
|
|
-- 12/03/09 gmj Added adGenTSCANFullRangeRate to allow all valid rates to be set for TSCAN
|
|
|
|
IMPORTS
|
|
Integer32,
|
|
Unsigned32,
|
|
TimeTicks,
|
|
OBJECT-TYPE,
|
|
MODULE-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
ifIndex
|
|
FROM IF-MIB
|
|
adEShdslInvIndex
|
|
FROM ADTRAN-SHDSL-MIB
|
|
adGenHDSL,
|
|
adGenHDSLID
|
|
FROM ADTRAN-GENHDSL-MIB;
|
|
|
|
adGenTSCANMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201209050000Z"
|
|
ORGANIZATION "Adtran, Inc."
|
|
CONTACT-INFO
|
|
"CND Tech Support
|
|
Postal: ADTRAN, Inc.
|
|
901 Explorer Blvd.
|
|
Huntsville, AL 35806
|
|
Tel: +1 800 726-8663
|
|
Fax: +1 256 963 6217
|
|
E-mail: support@adtran.com"
|
|
DESCRIPTION
|
|
"This MIB defines the objects for the TSCAN MIB."
|
|
|
|
REVISION "201209050000Z"
|
|
DESCRIPTION "Added adGenTSCANRepeaterTable and adGenTSCANRepeaterPortTable."
|
|
|
|
REVISION "200907300000Z"
|
|
DESCRIPTION "Created"
|
|
::= { adGenHDSLID 1 }
|
|
|
|
-- OBJECT IDENTIFIERS
|
|
|
|
adGenTSCANmg OBJECT IDENTIFIER ::= { adGenHDSL 1 }
|
|
|
|
adGenTSCANProv OBJECT IDENTIFIER ::= { adGenTSCANmg 1 }
|
|
|
|
adGenTSCANMibConformance OBJECT IDENTIFIER ::= { adGenTSCANmg 2 }
|
|
adGenTSCANMibGroups OBJECT IDENTIFIER ::= { adGenTSCANMibConformance 1 }
|
|
|
|
adGenTSCANRepeater OBJECT IDENTIFIER ::= { adGenTSCANmg 3 }
|
|
|
|
--###############################################################
|
|
-- T S C A N
|
|
--###############################################################
|
|
|
|
adGenTSCANProvTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenTSCANProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TSCAN Prov table."
|
|
::= { adGenTSCANProv 1 }
|
|
|
|
adGenTSCANProvEntry OBJECT-TYPE
|
|
SYNTAX AdGenTSCANProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the TSCAN Provisioning table."
|
|
INDEX { ifIndex }
|
|
::= { adGenTSCANProvTable 1 }
|
|
|
|
AdGenTSCANProvEntry ::=
|
|
SEQUENCE {
|
|
adGenTSCANAccumTscanData
|
|
INTEGER,
|
|
adGenTSCANTscanDataStatus
|
|
INTEGER,
|
|
adGenTSCANECTG1B1
|
|
DisplayString,
|
|
adGenTSCANECTG1B2
|
|
DisplayString,
|
|
adGenTSCANECTG1B3
|
|
DisplayString,
|
|
adGenTSCANECTG1B4
|
|
DisplayString,
|
|
adGenTSCANECTG1B5
|
|
DisplayString,
|
|
adGenTSCANECTG1B6
|
|
DisplayString,
|
|
adGenTSCANECTG1B7
|
|
DisplayString,
|
|
adGenTSCANECTG1B8
|
|
DisplayString,
|
|
adGenTSCANECTG1B9
|
|
DisplayString,
|
|
adGenTSCANECTG2B1
|
|
DisplayString,
|
|
adGenTSCANECTG2B2
|
|
DisplayString,
|
|
adGenTSCANECTG2B3
|
|
DisplayString,
|
|
adGenTSCANECTG2B4
|
|
DisplayString,
|
|
adGenTSCANECTG2B5
|
|
DisplayString,
|
|
adGenTSCANECTG2B6
|
|
DisplayString,
|
|
adGenTSCANECTG2B7
|
|
DisplayString,
|
|
adGenTSCANECTG2B8
|
|
DisplayString,
|
|
adGenTSCANECTG2B9
|
|
DisplayString,
|
|
adGenTSCANECTB1B1
|
|
DisplayString,
|
|
adGenTSCANECTB1B2
|
|
DisplayString,
|
|
adGenTSCANECTB1B3
|
|
DisplayString,
|
|
adGenTSCANECTB1B4
|
|
DisplayString,
|
|
adGenTSCANECTB1B5
|
|
DisplayString,
|
|
adGenTSCANECTB1B6
|
|
DisplayString,
|
|
adGenTSCANECTB1B7
|
|
DisplayString,
|
|
adGenTSCANECTB1B8
|
|
DisplayString,
|
|
adGenTSCANECTB1B9
|
|
DisplayString,
|
|
adGenTSCANECTB2B1
|
|
DisplayString,
|
|
adGenTSCANECTB2B2
|
|
DisplayString,
|
|
adGenTSCANECTB2B3
|
|
DisplayString,
|
|
adGenTSCANECTB2B4
|
|
DisplayString,
|
|
adGenTSCANECTB2B5
|
|
DisplayString,
|
|
adGenTSCANECTB2B6
|
|
DisplayString,
|
|
adGenTSCANECTB2B7
|
|
DisplayString,
|
|
adGenTSCANECTB2B8
|
|
DisplayString,
|
|
adGenTSCANECTB2B9
|
|
DisplayString,
|
|
adGenTSCANST1B
|
|
DisplayString,
|
|
adGenTSCANST2B
|
|
DisplayString,
|
|
adGenTSCANLS1
|
|
INTEGER,
|
|
adGenTSCANLS2
|
|
INTEGER,
|
|
adGenTSCANRate
|
|
INTEGER,
|
|
adGenTSCANLastTime
|
|
TimeTicks,
|
|
adGenTSCANRepeaterIndex
|
|
INTEGER,
|
|
adGenTSCANECTB1B10
|
|
DisplayString,
|
|
adGenTSCANECTB1B11
|
|
DisplayString,
|
|
adGenTSCANECTB1B12
|
|
DisplayString,
|
|
adGenTSCANECTB2B10
|
|
DisplayString,
|
|
adGenTSCANECTB2B11
|
|
DisplayString,
|
|
adGenTSCANECTB2B12
|
|
DisplayString,
|
|
adGenTSCANHybridConfig
|
|
INTEGER,
|
|
adGenTSCANFullRangeRate
|
|
Unsigned32
|
|
}
|
|
|
|
adGenTSCANAccumTscanData OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Starts the accumulation of the TSCAN data. Always returns 1 on get."
|
|
::= { adGenTSCANProvEntry 1 }
|
|
|
|
adGenTSCANTscanDataStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
done (1),
|
|
accumulating (2),
|
|
idle (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the TSCAN data accumulation process."
|
|
::= { adGenTSCANProvEntry 2 }
|
|
|
|
adGenTSCANECTG1B1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L1"
|
|
::= { adGenTSCANProvEntry 3 }
|
|
|
|
adGenTSCANECTG1B2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L1"
|
|
::= { adGenTSCANProvEntry 4 }
|
|
|
|
adGenTSCANECTG1B3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L1"
|
|
::= { adGenTSCANProvEntry 5 }
|
|
|
|
adGenTSCANECTG1B4 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L1"
|
|
::= { adGenTSCANProvEntry 6 }
|
|
|
|
adGenTSCANECTG1B5 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L1"
|
|
::= { adGenTSCANProvEntry 7 }
|
|
|
|
adGenTSCANECTG1B6 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L1"
|
|
::= { adGenTSCANProvEntry 8 }
|
|
|
|
adGenTSCANECTG1B7 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L1"
|
|
::= { adGenTSCANProvEntry 9 }
|
|
|
|
adGenTSCANECTG1B8 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L1"
|
|
::= { adGenTSCANProvEntry 10 }
|
|
|
|
adGenTSCANECTG1B9 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L1"
|
|
::= { adGenTSCANProvEntry 11 }
|
|
|
|
adGenTSCANECTG2B1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L2"
|
|
::= { adGenTSCANProvEntry 12 }
|
|
|
|
adGenTSCANECTG2B2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L2"
|
|
::= { adGenTSCANProvEntry 13 }
|
|
|
|
adGenTSCANECTG2B3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L2"
|
|
::= { adGenTSCANProvEntry 14 }
|
|
|
|
adGenTSCANECTG2B4 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L2"
|
|
::= { adGenTSCANProvEntry 15 }
|
|
|
|
adGenTSCANECTG2B5 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L2"
|
|
::= { adGenTSCANProvEntry 16 }
|
|
|
|
adGenTSCANECTG2B6 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L2"
|
|
::= { adGenTSCANProvEntry 17 }
|
|
|
|
adGenTSCANECTG2B7 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L2"
|
|
::= { adGenTSCANProvEntry 18 }
|
|
|
|
adGenTSCANECTG2B8 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L2"
|
|
::= { adGenTSCANProvEntry 19 }
|
|
|
|
adGenTSCANECTG2B9 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TG information for L2"
|
|
::= { adGenTSCANProvEntry 20 }
|
|
|
|
adGenTSCANECTB1B1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 21 }
|
|
|
|
adGenTSCANECTB1B2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 22 }
|
|
|
|
adGenTSCANECTB1B3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 23 }
|
|
|
|
adGenTSCANECTB1B4 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 24 }
|
|
|
|
adGenTSCANECTB1B5 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 25 }
|
|
|
|
adGenTSCANECTB1B6 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 26 }
|
|
|
|
adGenTSCANECTB1B7 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 27 }
|
|
|
|
adGenTSCANECTB1B8 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 28 }
|
|
|
|
adGenTSCANECTB1B9 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 29 }
|
|
|
|
adGenTSCANECTB2B1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 30 }
|
|
|
|
adGenTSCANECTB2B2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 31}
|
|
|
|
adGenTSCANECTB2B3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 32 }
|
|
|
|
adGenTSCANECTB2B4 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 33}
|
|
|
|
adGenTSCANECTB2B5 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 34 }
|
|
|
|
adGenTSCANECTB2B6 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 35 }
|
|
|
|
adGenTSCANECTB2B7 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 36 }
|
|
|
|
adGenTSCANECTB2B8 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 37 }
|
|
|
|
adGenTSCANECTB2B9 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 38 }
|
|
|
|
adGenTSCANST1B OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ST information for L1"
|
|
::= { adGenTSCANProvEntry 39 }
|
|
|
|
adGenTSCANST2B OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ST information for L2"
|
|
::= { adGenTSCANProvEntry 40 }
|
|
|
|
adGenTSCANLS1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid (1),
|
|
complete (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of current TSCAN data on L1."
|
|
::= { adGenTSCANProvEntry 41 }
|
|
|
|
adGenTSCANLS2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid (1),
|
|
complete (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of current TSCAN data on L2."
|
|
::= { adGenTSCANProvEntry 42 }
|
|
|
|
adGenTSCANRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sixteenDS0s(1),
|
|
thirtytwoDS0s(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provisions the rate that TSCAN will run. Currently,
|
|
this applies to SHDSL only. The default is 32."
|
|
::= { adGenTSCANProvEntry 43 }
|
|
|
|
adGenTSCANLastTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timestamp of last valid results for TScan."
|
|
::= { adGenTSCANProvEntry 44 }
|
|
|
|
adGenTSCANRepeaterIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
htuc(1),
|
|
hre1(2),
|
|
hre2(3),
|
|
hre3(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provisions the HTUC or repeater that operation will
|
|
be performed on. Only valid for hdsl4."
|
|
::= { adGenTSCANProvEntry 45 }
|
|
adGenTSCANECTB1B10 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 46 }
|
|
adGenTSCANECTB1B11 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 47 }
|
|
adGenTSCANECTB1B12 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L1"
|
|
::= { adGenTSCANProvEntry 48 }
|
|
adGenTSCANECTB2B10 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 49 }
|
|
adGenTSCANECTB2B11 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 50 }
|
|
adGenTSCANECTB2B12 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block of TB information for L2"
|
|
::= { adGenTSCANProvEntry 51 }
|
|
adGenTSCANHybridConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabled connects the hybrid during TSCAN,
|
|
disabled disconnects the hybrid during TSCAN."
|
|
::= { adGenTSCANProvEntry 52 }
|
|
adGenTSCANFullRangeRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provisions the rate in DS0s that TSCAN will run.
|
|
Currently, this applies to SHDSL only. The default
|
|
is 32. Allows any valid rate to be set."
|
|
::= { adGenTSCANProvEntry 53 }
|
|
|
|
|
|
--###############################################################
|
|
-- R E P E A T E R T S C A N
|
|
--###############################################################
|
|
|
|
adGenTSCANRepeaterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenTSCANRepeaterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TSCAN Repeater table."
|
|
::= { adGenTSCANRepeater 1 }
|
|
|
|
adGenTSCANRepeaterEntry OBJECT-TYPE
|
|
SYNTAX AdGenTSCANRepeaterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the TSCAN Repeater table. This table is used to initiate
|
|
and report results on repeaters in the circuit. Currently, this is only
|
|
for use with SHDSL repeaters."
|
|
INDEX { ifIndex, adEShdslInvIndex }
|
|
::= { adGenTSCANRepeaterTable 1 }
|
|
|
|
AdGenTSCANRepeaterEntry ::=
|
|
SEQUENCE {
|
|
adGenTSCANRepeaterStart
|
|
INTEGER,
|
|
adGenTSCANRepeaterStatus
|
|
INTEGER,
|
|
adGenTSCANRepeaterLastTestCompleted
|
|
DisplayString,
|
|
adGenTSCANRepeaterFault
|
|
INTEGER,
|
|
adGenTSCANRepeaterDistanceInFeet
|
|
Integer32,
|
|
adGenTSCANRepeaterDistanceInMeters
|
|
Integer32,
|
|
adGenTSCANRepeaterRate
|
|
Integer32
|
|
}
|
|
|
|
adGenTSCANRepeaterStart OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Starts the accumulation of the TSCAN data. Always returns 1 on get."
|
|
::= { adGenTSCANRepeaterEntry 1 }
|
|
|
|
adGenTSCANRepeaterStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
done(1),
|
|
accumulatingData(2),
|
|
idle(3),
|
|
error(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the TSCAN status of the selected repeater."
|
|
::= { adGenTSCANRepeaterEntry 2 }
|
|
|
|
adGenTSCANRepeaterLastTestCompleted OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the date/time of the last test ran in a MM/DD/YYYY HH:MM:SS format."
|
|
::= { adGenTSCANRepeaterEntry 3 }
|
|
|
|
adGenTSCANRepeaterFault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
open(1),
|
|
short(2),
|
|
gfi(3),
|
|
singleOpen(4),
|
|
ok(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the fault found during the last test."
|
|
::= { adGenTSCANRepeaterEntry 4 }
|
|
|
|
adGenTSCANRepeaterDistanceInFeet OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the distance, in feet, of the fault found in the last test."
|
|
::= { adGenTSCANRepeaterEntry 5 }
|
|
|
|
adGenTSCANRepeaterDistanceInMeters OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the distance, in meters, of the fault found in the last test."
|
|
::= { adGenTSCANRepeaterEntry 6 }
|
|
|
|
adGenTSCANRepeaterRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the SHDSL training rate, in DS0s, used in the last test."
|
|
::= { adGenTSCANRepeaterEntry 7 }
|
|
|
|
|
|
|
|
--###############################################################
|
|
adGenTSCANRepeaterPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenTSCANRepeaterPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TSCAN Repeater Port table."
|
|
::= { adGenTSCANRepeater 2 }
|
|
|
|
adGenTSCANRepeaterPortEntry OBJECT-TYPE
|
|
SYNTAX AdGenTSCANRepeaterPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the TSCAN Repeater Port table. This table is used to control
|
|
and/or report port level information related to running TSCAN on a repeater."
|
|
INDEX { ifIndex }
|
|
|
|
::= { adGenTSCANRepeaterPortTable 1 }
|
|
|
|
AdGenTSCANRepeaterPortEntry ::=
|
|
SEQUENCE {
|
|
adGenTSCANRepeaterPortLastErrorString
|
|
DisplayString
|
|
}
|
|
|
|
adGenTSCANRepeaterPortLastErrorString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the last error encountered when attempting to initiate a TSCAN test
|
|
on a repeater."
|
|
::= { adGenTSCANRepeaterPortEntry 1 }
|
|
|
|
|
|
-- ******************************************************************************************
|
|
-- MIB Groups
|
|
-- ******************************************************************************************
|
|
adGenTSCANGroup OBJECT-GROUP
|
|
OBJECTS
|
|
{
|
|
adGenTSCANAccumTscanData,
|
|
adGenTSCANTscanDataStatus,
|
|
adGenTSCANECTG1B1,
|
|
adGenTSCANECTG1B2,
|
|
adGenTSCANECTG1B3,
|
|
adGenTSCANECTG1B4,
|
|
adGenTSCANECTG1B5,
|
|
adGenTSCANECTG1B6,
|
|
adGenTSCANECTG1B7,
|
|
adGenTSCANECTG1B8,
|
|
adGenTSCANECTG1B9,
|
|
adGenTSCANECTG2B1,
|
|
adGenTSCANECTG2B2,
|
|
adGenTSCANECTG2B3,
|
|
adGenTSCANECTG2B4,
|
|
adGenTSCANECTG2B5,
|
|
adGenTSCANECTG2B6,
|
|
adGenTSCANECTG2B7,
|
|
adGenTSCANECTG2B8,
|
|
adGenTSCANECTG2B9,
|
|
adGenTSCANECTB1B1,
|
|
adGenTSCANECTB1B2,
|
|
adGenTSCANECTB1B3,
|
|
adGenTSCANECTB1B4,
|
|
adGenTSCANECTB1B5,
|
|
adGenTSCANECTB1B6,
|
|
adGenTSCANECTB1B7,
|
|
adGenTSCANECTB1B8,
|
|
adGenTSCANECTB1B9,
|
|
adGenTSCANECTB2B1,
|
|
adGenTSCANECTB2B2,
|
|
adGenTSCANECTB2B3,
|
|
adGenTSCANECTB2B4,
|
|
adGenTSCANECTB2B5,
|
|
adGenTSCANECTB2B6,
|
|
adGenTSCANECTB2B7,
|
|
adGenTSCANECTB2B8,
|
|
adGenTSCANECTB2B9,
|
|
adGenTSCANST1B,
|
|
adGenTSCANST2B,
|
|
adGenTSCANLS1,
|
|
adGenTSCANLS2,
|
|
adGenTSCANRate,
|
|
adGenTSCANLastTime,
|
|
adGenTSCANRepeaterIndex,
|
|
adGenTSCANECTB1B10,
|
|
adGenTSCANECTB1B11,
|
|
adGenTSCANECTB1B12,
|
|
adGenTSCANECTB2B10,
|
|
adGenTSCANECTB2B11,
|
|
adGenTSCANECTB2B12,
|
|
adGenTSCANHybridConfig,
|
|
adGenTSCANFullRangeRate
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide support for TSCAN."
|
|
::= { adGenTSCANMibGroups 1 }
|
|
|
|
|
|
END
|