Observium_CE/mibs/adtran/ADTRAN-GENMEVC-MIB

774 lines
26 KiB
Plaintext

ADTRAN-GENMEVC-MIB
-- TITLE: The ADTRAN MEVC MIB
-- PRODUCT: Metro Ethernet Products
-- VERSION: 1.0
-- DATE: 07/21/10
-- AUTHOR: Anil Shah
-- STATUS: PRELIMINARY
-- This MIB defines the object identifiers (OIDs) for the
-- ADTRAN GENMEVC MIB objects
-- HISTORY:
-- 2010/06/17 ams STATUS: PRELIMINARY.
-- 2010/07/21 ams Added a New table to report MEVC creation error. Added MEVC name as
-- a second index to report MEN Port creation error on MEVC. Added a
-- new table to display number of MEVCs on SLOT.
-- 2011/02/16 ams Added VLAN in use table.
--
-- *** DO NOT USE THIS FIELD. ***
-- ******************************************************************************************
DEFINITIONS ::= BEGIN
IMPORTS
adGenMEVC,
adGenMEVCID FROM ADTRAN-SHARED-CND-SYSTEM-MIB
OBJECT-TYPE,
MODULE-IDENTITY,
Integer32 FROM SNMPv2-SMI
DisplayString,
RowStatus,
TimeStamp FROM SNMPv2-TC
ifIndex,
InterfaceIndex FROM IF-MIB
adGenSlotInfoIndex FROM ADTRAN-GENSLOT-MIB
;
adGenMEVCMIB MODULE-IDENTITY
LAST-UPDATED "201501120000Z"
ORGANIZATION "Adtran, Inc."
CONTACT-INFO
"CND Tech Support
Postal: ADTRAN, Inc.
901 Explorer Blvd.
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"This MIB defines the objects for the MEVC MIB."
REVISION "201501120000Z"
DESCRIPTION "Added adGenMEVCIGMPImmediateLeave, adGenMEVCIGMPTimeoutInterval and adGenMEVCIGMPMode in the adGenMEVCTable
Added a New adGenMEVCIGMPTable table."
REVISION "201307030000Z"
DESCRIPTION "Added a adGenMEVCEnhMenPortTable to replace adGenMEVCMenPortTable.
This new table accepts interfaces from multiple slots to be added to MEVC."
REVISION "201108260000Z"
DESCRIPTION "Added Management Entry to MEVC Table."
REVISION "201102160000Z"
DESCRIPTION "Created"
::= { adGenMEVCID 1 }
adGenMEVCEvents OBJECT IDENTIFIER ::= {adGenMEVC 0}
adGenMEVCProvisioning OBJECT IDENTIFIER ::= {adGenMEVC 1}
--==================================================================================================================
adGenMEVCTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenMEVCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEVC provisioning table."
::= { adGenMEVCProvisioning 1 }
adGenMEVCEntry OBJECT-TYPE
SYNTAX AdGenMEVCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the MEVC provisioning table. MEVC entries
are uniquely identified on Slot as well as by the MEvc
Name."
INDEX { adGenSlotInfoIndex, IMPLIED adGenMEVCName }
::= { adGenMEVCTable 1 }
AdGenMEVCEntry ::=
SEQUENCE {
adGenMEVCName
DisplayString,
adGenMEVCRowStatus
RowStatus,
adGenMEVCOperStatus
INTEGER,
adGenMEVCStatus
DisplayString,
adGenMEVCSTagVID
Integer32,
adGenMEVCPreserveCEVlanId
INTEGER,
adGenMEVCMacSwitching
INTEGER,
adGenMEVCNumberOfInterfaces
Integer32,
adGenMEVCLastError
DisplayString,
adGenMevcManagement
INTEGER,
adGenMEVCIGMPImmediateLeave
INTEGER,
adGenMEVCIGMPTimeOutInterval
INTEGER,
adGenMEVCIGMPMode
INTEGER
}
adGenMEVCName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..50))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A user configurable name for the MEVC. Upon creation of the MEVC,
the associated name will default to a unique value."
::= { adGenMEVCEntry 1}
adGenMEVCRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or modify or delete an
existing row in the MEVC table."
::= { adGenMEVCEntry 2}
adGenMEVCOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the current operational status of the MEVC."
::= { adGenMEVCEntry 3}
adGenMEVCStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable provides the MEVC status. If there is no error, the MEVC
status will be 'running'. If there is an error and the MEVC cannot be
applied, then adGenMEVCStatus will provide more details about the error."
::= { adGenMEVCEntry 4}
adGenMEVCSTagVID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable specifies the outermost VLAN S-Tag VID for
frames on this MEVC. No two entries in the MEVC Table may
have the same S-Tag VID.
S-Tag values 0 and 4095 are reserved and should not be used.
Set the S-Tag to 4096 for untagged traffic and to 4097 for
priority tagged traffic."
::= { adGenMEVCEntry 5}
adGenMEVCPreserveCEVlanId OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This option provisions whether to preserve the CE VLAN tag
received at the UNI port. Select enabled to push the MEVC tag
onto the CE tag for frames destined for this MEVC. Select
disabled to remove the CE VLAN tag and to add the MEVC tag
for the frames destined for this MEVC."
::= { adGenMEVCEntry 6}
adGenMEVCMacSwitching OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This option provisions whether MAC Switching should be
performed on this MEVC."
::= { adGenMEVCEntry 7}
adGenMEVCNumberOfInterfaces OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the number of interfaces connected to this MEVC."
::= {adGenMEVCEntry 8}
adGenMEVCLastError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string describes the last error experienced
for this particular entry in the table."
::= { adGenMEVCEntry 9 }
adGenMevcManagement OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
local(2),
system(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This option provisions management vlan traffic
switching setting.
Disable - Only non-management Vlan traffic switching.
Local - Management Vlan traffic switched locally.
System - Management Vlan traffic switched through the system."
::= { adGenMEVCEntry 10 }
adGenMEVCIGMPImmediateLeave OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/Disable immediate leave. "
DEFVAL { disabled }
::= { adGenMEVCEntry 11 }
adGenMEVCIGMPTimeOutInterval OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IGMP group membership interval in units of seconds.
If no IGMP join is received for a video group before this
interval expires, then the video group is removed for
the host interface."
DEFVAL { 260 }
::= { adGenMEVCEntry 12 }
adGenMEVCIGMPMode OBJECT-TYPE
SYNTAX INTEGER
{
transparent(1),
snooping(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IGMP Mode associated with this MEVC ."
DEFVAL { transparent }
::= { adGenMEVCEntry 13}
--==================================================================================================================
adGenMEVCLookupTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenMEVCLookupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEVC lookup table."
::= { adGenMEVCProvisioning 2 }
adGenMEVCLookupEntry OBJECT-TYPE
SYNTAX AdGenMEVCLookupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the MEVC lookup table. This table has one
entry for each row in the adGenMEVCTable. This table is
used to find the MEVC name for a given SLOT and S-Tag
VLAN Id."
INDEX { adGenSlotInfoIndex, adGenMEVCLookupSTag }
::= { adGenMEVCLookupTable 1 }
AdGenMEVCLookupEntry ::=
SEQUENCE {
adGenMEVCLookupSTag
Integer32,
adGenMEVCLookupName
DisplayString
}
adGenMEVCLookupSTag OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The S-Tag VLAN Id.
S-Tag values 0, 1, and 4095 are reserved and should not be used.
Set the S-Tag to 4096 for untagged traffic and to 4097 for
priority tagged traffic."
::= { adGenMEVCLookupEntry 1}
adGenMEVCLookupName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the MEVC name associated with the given S-Tag VID."
::= { adGenMEVCLookupEntry 2}
--==================================================================================================================
adGenMEVCErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenMEVCErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEVC Creation Error table."
::= { adGenMEVCProvisioning 3 }
adGenMEVCErrorEntry OBJECT-TYPE
SYNTAX AdGenMEVCErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the MEVC Creation Error table.
The index, adGenSlotInfoIndex, identifies the SLOT."
INDEX { adGenSlotInfoIndex}
::= { adGenMEVCErrorTable 1 }
AdGenMEVCErrorEntry ::=
SEQUENCE {
adGenMEVCError
DisplayString
}
adGenMEVCError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns information about the last error for the MEVC
create on SLOT. If row creation fails, this string
will provide details about why the row could not be created."
::= { adGenMEVCErrorEntry 1}
--==================================================================================================================
adGenMEVCMenPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenMEVCMenPortEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The MEVC MEN Port table.
NOTE: This table has been deprecated and replaced by
the adGenMEVCEnhMenPortTable. The OIDs within
this table always assume slot and port identified
via ifIndex."
::= { adGenMEVCProvisioning 4 }
adGenMEVCMenPortEntry OBJECT-TYPE
SYNTAX AdGenMEVCMenPortEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in the MEVC MEN Port table. This table can be
used to add or remove MEN Port connections for an MEVC.
The first index, ifIndex, identifies the MEN port.
The second index, adGenProvisionedMEVCName, identifies the MEVC.
NOTE: This table has been deprecated and replaced by
the adGenMEVCEnhMenPortTable. The OIDs within
this table always assume slot and port identified
via ifIndex."
INDEX { ifIndex, adGenProvisionedMEVCName }
::= { adGenMEVCMenPortTable 1 }
AdGenMEVCMenPortEntry ::=
SEQUENCE {
adGenProvisionedMEVCName
OCTET STRING,
adGenMEVCMenPortRowStatus
RowStatus,
adGenMEVCMenPortConnectionType
INTEGER
}
adGenProvisionedMEVCName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..50))
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A user configurable name for the MEVC. Upon creation of the MEVC,
the associated name will default to a unique value.
NOTE: This table has been deprecated and replaced by
the adGenMEVCEnhMenPortTable. The OIDs within
this table always assume slot and port identified
via ifIndex."
::= { adGenMEVCMenPortEntry 1}
adGenMEVCMenPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object is used to create or destroy a MEN Port
connection for an MEVC.
NOTE: This table has been deprecated and replaced by
the adGenMEVCEnhMenPortTable. The OIDs within
this table always assume slot and port identified
via ifIndex."
::= { adGenMEVCMenPortEntry 2}
adGenMEVCMenPortConnectionType OBJECT-TYPE
SYNTAX INTEGER {
root(1),
leaf(2)
}
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This option provisions whether the MEN port is a root
or leaf of the given MEVC.
NOTE: This table has been deprecated and replaced by
the adGenMEVCEnhMenPortTable. The OIDs within
this table always assume slot and port identified
via ifIndex."
DEFVAL { root }
::= { adGenMEVCMenPortEntry 3}
--==================================================================================================================
adGenMEVCMenPortConnectionErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenMEVCMenPortConnectionErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEVC MEN Port Connection Error table."
::= { adGenMEVCProvisioning 5 }
adGenMEVCMenPortConnectionErrorEntry OBJECT-TYPE
SYNTAX AdGenMEVCMenPortConnectionErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the MEVC MEN Port Connection Error table.
The first index, adGenSlotInfoIndex, identifies the SLOT.
The second index, adGenProvisionedMenPortMEVCName, identifies the MEVC"
INDEX { adGenSlotInfoIndex, adGenProvisionedMenPortMEVCName}
::= { adGenMEVCMenPortConnectionErrorTable 1 }
AdGenMEVCMenPortConnectionErrorEntry ::=
SEQUENCE {
adGenProvisionedMenPortMEVCName
OCTET STRING,
adGenMEVCMenPortConnectionError
DisplayString
}
adGenProvisionedMenPortMEVCName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..50))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A user configured name for the MEVC."
::= { adGenMEVCMenPortConnectionErrorEntry 1}
adGenMEVCMenPortConnectionError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns information about the last error for the MEVC
MEN Port table on SLOT. If row creation fails, this string
will provide details about why the row could not be created."
::= { adGenMEVCMenPortConnectionErrorEntry 2}
--==================================================================================================================
adGenMEVCMenPortProvisioningTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenMEVCMenPortProvisioningEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEVC MEN Port Provisioning table."
::= { adGenMEVCProvisioning 6 }
adGenMEVCMenPortProvisioningEntry OBJECT-TYPE
SYNTAX AdGenMEVCMenPortProvisioningEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the MEVC MEN Port Provisioning table.
This table can be used to provision a MEN port. The
index for this table is the ifIndex of the MEN port."
INDEX { ifIndex }
::= { adGenMEVCMenPortProvisioningTable 1 }
AdGenMEVCMenPortProvisioningEntry ::=
SEQUENCE {
adGenMEVCMenPortStagDei
INTEGER
}
adGenMEVCMenPortStagDei OBJECT-TYPE
SYNTAX INTEGER {
disabled (1),
enabled (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This option provisions the marking of the DEI bit.
When enabled, the bit functions as the Drop Eligible Indicator.
When disabled, the bit functions as the Canonical Format Indicator."
::= { adGenMEVCMenPortProvisioningEntry 1 }
--==================================================================================================================
adGenMEVCNumberOfMEVCsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenMEVCNumberOfMEVCsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEVC table to display number Of MEVCs associated with the Slot."
::= { adGenMEVCProvisioning 7 }
adGenMEVCNumberOfMEVCsEntry OBJECT-TYPE
SYNTAX AdGenMEVCNumberOfMEVCsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the MEVC Number of MEVCs table.
The index, adGenSlotInfoIndex, identifies the SLOT."
INDEX { adGenSlotInfoIndex }
::= { adGenMEVCNumberOfMEVCsTable 1 }
AdGenMEVCNumberOfMEVCsEntry ::=
SEQUENCE {
adGenMEVCNumberOfMEVCs
Integer32
}
adGenMEVCNumberOfMEVCs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable is used to display number of MEVCs associated
with the Slot."
::= { adGenMEVCNumberOfMEVCsEntry 1}
--==================================================================================================================
adGenVLANInUseLookupTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenVLANInUseLookupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VLAN In Use lookup table."
::= { adGenMEVCProvisioning 8 }
adGenVLANInUseLookupEntry OBJECT-TYPE
SYNTAX AdGenVLANInUseLookupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the VLAN In Use lookup table. This table is use to
determine which VLANs are in use on specific SLOT."
INDEX { adGenSlotInfoIndex }
::= { adGenVLANInUseLookupTable 1 }
AdGenVLANInUseLookupEntry ::=
SEQUENCE {
adGenVLANInUseLookupData
OCTET STRING
}
adGenVLANInUseLookupData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(512))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A binary string is returned, where each VLAN is represented
as a - bit, where 1 is in use, 0 is not in use. This applies
for all 4096 VLANs. Following is how VLANs are represented in
Octet string:
VLAN 0 - Octet byte 1, bit 7(MSB)
VLAN 1 - Octet byte 1, bit 6
VLAN 2 - Octet byte 1, bit 5
....
VLAN 7 - Octet byte 1, bit 0(LSB)
VLAN 8 - Octet byte 2, bit 7(MSB)
....
VLAN 4095 - Octet byte 512, bit 0(LSB)"
::= { adGenVLANInUseLookupEntry 1 }
--==================================================================================================================
adGenMEVCEnhMenPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenMEVCEnhMenPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEVC MEN Port table."
::= { adGenMEVCProvisioning 9 }
adGenMEVCEnhMenPortEntry OBJECT-TYPE
SYNTAX AdGenMEVCEnhMenPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the MEVC MEN Port table. This table can be
used to add or remove MEN Port connections for an MEVC.
The first index, identifies slot number associated with MEVC name.
The second index, adGenMEVCMenPortIfIndex, identifies the MEN port.
The third index, adGenProvMEVCName, identifies the MEVC"
INDEX { adGenSlotInfoIndex, adGenMEVCMenPortIfIndex, adGenProvMEVCName }
::= { adGenMEVCEnhMenPortTable 1 }
AdGenMEVCEnhMenPortEntry ::=
SEQUENCE {
adGenMEVCMenPortIfIndex
InterfaceIndex,
adGenProvMEVCName
OCTET STRING,
adGenMEVCEnhMenPortRowStatus
RowStatus,
adGenMEVCEnhMenPortConnectionType
INTEGER
}
adGenMEVCMenPortIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This interface index of the MEN port to be connected to this EVC."
::= { adGenMEVCEnhMenPortEntry 1}
adGenProvMEVCName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..50))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A user configurable name for the MEVC. Upon creation of the MEVC,
the associated name will default to a unique value."
::= { adGenMEVCEnhMenPortEntry 2}
adGenMEVCEnhMenPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create or destroy a MEN Port
connection for an MEVC."
::= { adGenMEVCEnhMenPortEntry 3}
adGenMEVCEnhMenPortConnectionType OBJECT-TYPE
SYNTAX INTEGER {
root(1),
leaf(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This option provisions whether the MEN port is a root
or leaf of the given MEVC."
DEFVAL { root }
::= { adGenMEVCEnhMenPortEntry 4}
--==================================================================================================================
adGenMEVCIGMPTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenMEVCIGMPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The MEVC IGMP table."
::= { adGenMEVCProvisioning 10}
adGenMEVCIGMPEntry OBJECT-TYPE
SYNTAX AdGenMEVCIGMPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the MEVC IGMP table. This table can be
used to enable or disable the interface mode to either
of the igmp host or router . The first index, identifies
slot number associated with the mevc name. The second index,
adGenMEVCIGMPInterfaceIndex, identifies the port. Third index,
adGenMEVCName identifies the mevc name."
INDEX { adGenSlotInfoIndex, adGenMEVCIGMPInterfaceIndex, adGenMEVCIGMPEVCName }
::= { adGenMEVCIGMPTable 1 }
AdGenMEVCIGMPEntry ::=
SEQUENCE {
adGenMEVCIGMPInterfaceIndex InterfaceIndex,
adGenMEVCIGMPEVCName OCTET STRING,
adGenMEVCIGMPInterfaceMode INTEGER,
adGenMEVCIGMPRowStatus RowStatus,
adGenMEVCIGMPLastError DisplayString
}
adGenMEVCIGMPInterfaceIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This interface index of the port on which IGMP mode is configured."
::= { adGenMEVCIGMPEntry 1}
adGenMEVCIGMPEVCName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..50))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A user configurable name for the MEVC. Upon creation of the MEVC,
the associated name will default to a unique value."
::= { adGenMEVCIGMPEntry 2}
adGenMEVCIGMPInterfaceMode OBJECT-TYPE
SYNTAX INTEGER {
host(1),
router(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"host - RFC2236 host facing interface. Enable the interface act as IGMP host.
router - RFC2236 Router facing interface. Enable the interface act as IGMP router."
DEFVAL { host }
::= { adGenMEVCIGMPEntry 3}
adGenMEVCIGMPRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create or modify or destroy a IGMP mode
on interface for an MEVC."
::= { adGenMEVCIGMPEntry 4}
adGenMEVCIGMPLastError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns information about the last error for the MEVC
IGMP table on slot. If row creation fails, this string
will provide details about why the row could not be created."
::= { adGenMEVCIGMPEntry 5 }
END