Observium_CE/mibs/adtran/ADTRAN-GENBONDING-MIB

388 lines
12 KiB
Plaintext

ADTRAN-GENBONDING-MIB DEFINITIONS ::= BEGIN
-- TITLE: Adtran Generic Bonding MIB
-- DATE: Aug 4, 2006
--
-- REVISION HISTORY: Date Comments
-- 08/04/2006 gdo - Initial release.
-- This MIB defines the generic MIB for the Mini-DSLAM products.
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION,DisplayString, RowStatus
FROM SNMPv2-TC
adGenSlotInfoIndex
FROM ADTRAN-GENSLOT-MIB
adGenBondingID
FROM ADTRAN-GENMINIDSLAM-MIB;
adGenBonding MODULE-IDENTITY
LAST-UPDATED "200608041650Z"
ORGANIZATION "ADTRAN, Inc."
CONTACT-INFO
"CND Tech Support
Postal: ADTRAN, Inc.
901 Explorer Blvd.
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"The MIB module for managing bonding of interfaces."
::= { adGenBondingID 1 }
adGenBondingMib OBJECT IDENTIFIER ::= { adGenBonding 1 }
adGenBondingMibObjects OBJECT IDENTIFIER ::= {adGenBondingMib 1}
adGenBondingMibConformance OBJECT IDENTIFIER ::= { adGenBondingMib 2 }
-- Textual conventions
AdGenBondingPort ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Index value for the bond-able port. This is effectively the same
as the adGenPortInfoIndex. Not all ports can use bonding however,
hence the use of this TC."
SYNTAX Integer32
--
-- The Bonding Group table consists of the number of Bonding groups and a
-- table of Bonding groups.
--
adGenBondingSlotInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenBondingSlotInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bonding Group Slot Information table."
::= { adGenBondingMibObjects 1 }
adGenBondingSlotInfoEntry OBJECT-TYPE
SYNTAX AdGenBondingSlotInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Bonding Group Slot Info table."
INDEX { adGenSlotInfoIndex }
::= { adGenBondingSlotInfoTable 1 }
AdGenBondingSlotInfoEntry ::= SEQUENCE {
adGenBondingGroupNumberNext Integer32,
adGenGenBondingSlotStatus DisplayString
}
adGenBondingGroupNumberNext OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the next available group number for this slot."
::= { adGenBondingSlotInfoEntry 1 }
adGenGenBondingSlotStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Error status messages for bonding groups on a slot."
::= { adGenBondingSlotInfoEntry 2 }
adGenBondingGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenBondingGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bonding Group Configuration table."
::= { adGenBondingMibObjects 2 }
adGenBondingGroupEntry OBJECT-TYPE
SYNTAX AdGenBondingGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Bonding Group table."
INDEX { adGenSlotInfoIndex,
adGenBondingGroupIndex }
::= { adGenBondingGroupTable 1 }
AdGenBondingGroupEntry ::= SEQUENCE {
adGenBondingGroupIndex Integer32,
adGenBondingGroupRowStatus RowStatus,
adGenBondingGroupName DisplayString,
adGenBondingGroupPortsString DisplayString,
adGenBondingGroupNumPorts Integer32
}
adGenBondingGroupIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for the Bonding Group."
::= { adGenBondingGroupEntry 1 }
adGenBondingGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object permits the creation or deletion of rows from
the adGenBondingGroupTable.
To create a new row of the adGenBondingGroupTable, this object
must first be set to createAndGo or createAndWait.
If settable, a successful set of the adGenBondingGroupPortsString
must be performed before the adGenBondingGroupRowStatus of a new
row can be changed to the active state. Optionally, a name may
be given to a row by changing the object adGenBondingGroupName.
The ports associated with a bonding group may only be changed while
the conceptual row's adGenBondingGroupRowStatus object is set to the
'notInService' state.
To remove (delete) an adGenBondingGroupTable entry from this table, set
adGenBondingGroupRowStatus to 'destroy'."
::= { adGenBondingGroupEntry 2 }
adGenBondingGroupName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A user defineable name for the Bonding Group."
::= { adGenBondingGroupEntry 3 }
adGenBondingGroupPortsString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Returns a string with the ports which are a member of this group.
The string is formatted with hyphens and commas where applicable.
Example: '2,3' or '2,5-12'"
::= { adGenBondingGroupEntry 4 }
adGenBondingGroupNumPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ports currently assigned to the group."
::= { adGenBondingGroupEntry 5 }
--
-- The Bonding Ports Table
--
-- The Bonding Ports Table consists of a table of bonded ports. Each row
-- in the table contains status information about a port which is part
-- of a bonding group, and also contains a configuration object to select
-- to which bonding group the port belongs.
--
adGenBondingPortsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenBondingPortsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bonding Port Status and Configuration table."
::= { adGenBondingMibObjects 3 }
adGenBondingPortsEntry OBJECT-TYPE
SYNTAX AdGenBondingPortsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Bonding Ports table."
INDEX { adGenSlotInfoIndex,
adGenBondingPortsIndex }
::= { adGenBondingPortsTable 1 }
AdGenBondingPortsEntry ::= SEQUENCE {
adGenBondingPortsIndex AdGenBondingPort,
adGenBondingPortsGroupMembership Integer32 }
adGenBondingPortsIndex OBJECT-TYPE
SYNTAX AdGenBondingPort
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This corresponds to the 'adGenPortInfoIndex' of the interface
on which this port is established."
::= { adGenBondingPortsEntry 1 }
adGenBondingPortsGroupMembership OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The group number this port is assigned to. If the port is not
assigned to any group, or if bonding isn't used on this port assign
the port to group 0 (doesn't exist). Some implementations may
choose to make this object read-only and instead rely on
adGenBondingPortsString to assign ports to a group."
::= { adGenBondingPortsEntry 2 }
--
-- The Bonding Ports Status Table
--
-- The Bonding Status Table consists of a table of bonded ports. Each row
-- contains status information about a port which is part of a bonding group.
-- Unbonded ports do not return any information in this table.
--
adGenBondingPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenBondingPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bonding Port Status table."
::= { adGenBondingMibObjects 4 }
adGenBondingPortStatusEntry OBJECT-TYPE
SYNTAX AdGenBondingPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Bonding Ports table."
INDEX { adGenSlotInfoIndex,
adGenBondingGroupIndex,
adGenBondingPortStatusPortIndex }
::= { adGenBondingPortStatusTable 1 }
AdGenBondingPortStatusEntry ::= SEQUENCE {
adGenBondingPortStatusPortIndex AdGenBondingPort,
adGenBondingPortGroupState INTEGER,
adGenBondingPortDiffDelay Integer32,
adGenBondingPortTxId Integer32,
adGenBondingPortRxId Integer32}
adGenBondingPortStatusPortIndex OBJECT-TYPE
SYNTAX AdGenBondingPort
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This corresponds to the 'adGenPortInfoIndex' of the interface
on which this port is established."
::= { adGenBondingPortStatusEntry 1 }
adGenBondingPortGroupState OBJECT-TYPE
SYNTAX INTEGER {
notProvisioned(1),
notUsable(2),
readyForTraffic(3),
carryingTraffic(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This corresponds to the 'adGenPortInfoIndex' of the interface
on which this port is established."
::= { adGenBondingPortStatusEntry 2 }
adGenBondingPortDiffDelay OBJECT-TYPE
SYNTAX Integer32
UNITS "100 microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential delay for this link."
::= { adGenBondingPortStatusEntry 3 }
adGenBondingPortTxId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit ID used for this link."
::= { adGenBondingPortStatusEntry 4 }
adGenBondingPortRxId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link ID received from the far end by this link."
::= { adGenBondingPortStatusEntry 5 }
-- Conformance Information
adGenBondingMibGroups OBJECT IDENTIFIER ::= { adGenBondingMibConformance 1 }
adGenBondingMibCompliances OBJECT IDENTIFIER ::= { adGenBondingMibConformance 2 }
-- Compliance Statements
adGenBondingMibCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for network elements implementing
the ADTRAN Generic Bonding MIB."
MODULE -- this module
-- Mandatory Part
MANDATORY-GROUPS {
adGenBondingGroupGroup,
adGenBondingPortsGroup,
adGenBondingPortStatusGroup }
-- Compliance Part
OBJECT adGenBondingPortsGroupMembership
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. Some implementations
may choose to rely instead on adGenBondingPortsString
in order to assign ports to a group."
::= { adGenBondingMibCompliances 1 }
-- Units of Conformance
adGenBondingGroupGroup OBJECT-GROUP
OBJECTS {
adGenBondingGroupNumberNext,
adGenBondingGroupRowStatus,
adGenBondingGroupPortsString,
adGenBondingGroupNumPorts }
STATUS current
DESCRIPTION
"A set of objects used in the configuration and
retrieval of status for a bonding group."
::= { adGenBondingMibGroups 1 }
adGenBondingPortsGroup OBJECT-GROUP
OBJECTS {
adGenBondingPortsGroupMembership }
STATUS current
DESCRIPTION
"A set of objects which allow configuration for a
bond-able link."
::= { adGenBondingMibGroups 2 }
adGenBondingPortStatusGroup OBJECT-GROUP
OBJECTS {
adGenBondingPortGroupState,
adGenBondingPortDiffDelay,
adGenBondingPortTxId,
adGenBondingPortRxId }
STATUS current
DESCRIPTION
"A set of objects providing status for a bonded link."
::= { adGenBondingMibGroups 3 }
END