ADTRAN-GENAUTOCONFIG-MIB
|
|
|
|
-- TITLE: The ADTRAN Auto-Config MIB
|
|
-- PRODUCT: ADTRAN products supporting Auto-Config
|
|
-- VERSION: 1.0
|
|
-- DATE: 10/13/2014
|
|
-- AUTHOR: Byron Young
|
|
-- STATUS: PRELIMINARY
|
|
|
|
-- This MIB defines the object identifiers (OIDs) for the ADTRAN Auto-Config MIB objects
|
|
|
|
-- ******************************************************************************************
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
InetAddressIPv4,
|
|
InetAddressIPv6
|
|
FROM INET-ADDRESS-MIB
|
|
sysName
|
|
FROM SNMPv2-MIB
|
|
TruthValue,
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
adTrapInformSeqNum
|
|
FROM ADTRAN-GENTRAPINFORM-MIB
|
|
adGenAutoConfig,
|
|
adGenAutoConfigID
|
|
FROM ADTRAN-SHARED-CND-SYSTEM-MIB
|
|
adGenSlotProdPartNumber,
|
|
adGenSlotProdSwVersion
|
|
FROM ADTRAN-GENSLOT-MIB
|
|
;
|
|
|
|
adGenAutoConfigMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201410130000Z"
|
|
ORGANIZATION "Adtran, Inc."
|
|
CONTACT-INFO
|
|
"CND Tech Support
|
|
Postal: ADTRAN, Inc.
|
|
901 Explorer Blvd.
|
|
Huntsville, AL 35806
|
|
Tel: +1 800 726 8663
|
|
Fax: +1 256 963 6217
|
|
E-mail: support@adtran.com"
|
|
DESCRIPTION
|
|
"This MIB defines the objects for the Auto-Config MIB."
|
|
|
|
REVISION "201410130000Z"
|
|
DESCRIPTION "Created"
|
|
|
|
::= { adGenAutoConfigID 1 }
|
|
|
|
adGenAutoConfigEvents OBJECT IDENTIFIER ::= {adGenAutoConfig 0}
|
|
adGenAutoConfigStatus OBJECT IDENTIFIER ::= {adGenAutoConfig 1}
|
|
adGenAutoConfigProvisioning OBJECT IDENTIFIER ::= {adGenAutoConfig 2}
|
|
|
|
adGenAutoConfigEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Auto-Config administrative state. When set to true, the
|
|
Auto-Config feature is enabled on the network element."
|
|
::= {adGenAutoConfigStatus 1}
|
|
|
|
adGenAutoConfigHostIPv4 OBJECT-TYPE
|
|
SYNTAX InetAddressIPv4
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The file server IPv4 address"
|
|
::= {adGenAutoConfigStatus 2}
|
|
|
|
adGenAutoConfigHostIPv6 OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The file server IPv6 address"
|
|
::= {adGenAutoConfigStatus 3}
|
|
|
|
adGenAutoConfigFilename OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Auto-Config filename. This is the first file retrieved and
|
|
parsed by the network element during the Auto-Config sequence.
|
|
This file contains options and filenames that apply to the remainder
|
|
of the Auto-Config sequence. This value provides the filename after
|
|
any variable substitution is performed."
|
|
::= {adGenAutoConfigStatus 4}
|
|
|
|
adGenAutoConfigGroupName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Auto-Config group name. The network element will substitute
|
|
this value in filenames that contain a predefined keyword. This
|
|
can be useful for customization purposes."
|
|
::= {adGenAutoConfigStatus 5}
|
|
|
|
adGenAutoConfigTempConfigFilename OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Auto-Config temporary configuration filename. This is a network
|
|
element configuration file that can exist on the server for troubleshooting
|
|
purposes. The network element will attempt to retrieve configuration files
|
|
in the following order:
|
|
1) temporary config
|
|
2) unit config
|
|
3) base config
|
|
The network element learns this filename via the auto-config file.
|
|
This value provides the filename after any variable substitution is
|
|
performed."
|
|
::= {adGenAutoConfigStatus 6}
|
|
|
|
adGenAutoConfigUnitConfigFilename OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Auto-Config unit configuration filename. This is a network
|
|
element configuration file that can exist on the server for normal
|
|
operation. The network element will attempt to retrieve configuration
|
|
files in the following order:
|
|
1) temporary config
|
|
2) unit config
|
|
3) base config
|
|
The network element learns this filename via the auto-config file.
|
|
This value provides the filename after any variable substitution is
|
|
performed."
|
|
::= {adGenAutoConfigStatus 7}
|
|
|
|
adGenAutoConfigBaseConfigFilename OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Auto-Config base configuration filename. This is a network
|
|
element configuration file that can exist on the server to provide
|
|
a common initial configuration for multiple network elements.
|
|
The network element will attempt to retrieve configuration files in
|
|
the following order:
|
|
1) temporary config
|
|
2) unit config
|
|
3) base config
|
|
The network element learns this filename via the auto-config file.
|
|
This value provides the filename after any variable substitution is
|
|
performed."
|
|
::= {adGenAutoConfigStatus 8}
|
|
|
|
adGenAutoConfigFirmwareDefinitionFilename OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Auto-Config firmware definition filename. This file lists
|
|
firmware filename(s) that the network element should retrieve
|
|
during the Auto-Config sequence. The network element learns this
|
|
firmware definition filename via the auto-config file. This value
|
|
provides the filename after any variable substitution is performed."
|
|
::= {adGenAutoConfigStatus 9}
|
|
|
|
adGenAutoConfigRetryCount OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..10 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Auto-Config retry count. When the network element attempts to
|
|
retrieve a file from the server, it will restart the Auto-Config
|
|
sequence if this maximum number of application-layer retries is
|
|
exhausted."
|
|
::= {adGenAutoConfigStatus 10}
|
|
|
|
adGenAutoConfigPollingInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..2592000 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Auto-Config polling interval in seconds. The network element will
|
|
periodically restart the Auto-Config sequence on this interval. A value
|
|
of zero disables the periodic restart of the sequence."
|
|
::= {adGenAutoConfigStatus 11}
|
|
|
|
adGenAutoConfigProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER { tftp(1), ftp(2), sftp(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The file transfer protocol that the network element uses to retrieve
|
|
files from the server during the Auto-Config sequence."
|
|
::= {adGenAutoConfigStatus 12}
|
|
|
|
adGenAutoConfigProtocolPortSFTP OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 1..65535 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TCP port number that applies when the protocol is SFTP."
|
|
::= {adGenAutoConfigStatus 13}
|
|
|
|
adGenAutoConfigLastFailureFilename OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the network element encounters a problem that causes the Auto-Config
|
|
sequence to fail, this value will provide the filename that relates to
|
|
the failure. This value provides the filename after any variable
|
|
substitution is performed."
|
|
::= {adGenAutoConfigStatus 14}
|
|
|
|
adGenAutoConfigLastFailureReason OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the network element encounters a problem that causes the Auto-Config
|
|
sequence to fail, this value will provide a descriptive reason for the
|
|
failure."
|
|
::= {adGenAutoConfigStatus 15}
|
|
|
|
adGenAutoConfigCurrentStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value provides the current status of the Auto-Config subsystem."
|
|
::= {adGenAutoConfigStatus 16}
|
|
|
|
adGenAutoConfigFailureAlmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
info(2),
|
|
alert(3),
|
|
minor(4),
|
|
major(5),
|
|
critical(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm severity for the Auto-Config failure alarm."
|
|
::= {adGenAutoConfigStatus 17}
|
|
|
|
adGenAutoConfigTimeoutAlmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
info(2),
|
|
alert(3),
|
|
minor(4),
|
|
major(5),
|
|
critical(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm severity for the Auto-Config timeout alarm."
|
|
::= {adGenAutoConfigStatus 18}
|
|
|
|
adGenAutoConfigRestart OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
restart(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When Auto-Config is enabled, this value can be set to cause the
|
|
Auto-Config sequence to restart."
|
|
::= {adGenAutoConfigProvisioning 1}
|
|
|
|
adGenAutoConfigFailureAlm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenAutoConfigFailureAlmSeverity,
|
|
adGenSlotProdPartNumber,
|
|
adGenSlotProdSwVersion,
|
|
adGenAutoConfigHostIPv4,
|
|
adGenAutoConfigHostIPv6,
|
|
adGenAutoConfigFilename,
|
|
adGenAutoConfigGroupName,
|
|
adGenAutoConfigTempConfigFilename,
|
|
adGenAutoConfigUnitConfigFilename,
|
|
adGenAutoConfigBaseConfigFilename,
|
|
adGenAutoConfigFirmwareDefinitionFilename,
|
|
adGenAutoConfigLastFailureFilename,
|
|
adGenAutoConfigLastFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates a failure in the Auto-Config sequence
|
|
that may require user intervention to resolve. Possible reasons the
|
|
network element may activate this alarm may include:
|
|
1) A received file is rejected because it is corrupt
|
|
2) A received file is rejected because it does not apply to the
|
|
network element or does not meet minimum requirements
|
|
3) A critical file does not exist on the file server"
|
|
--#TYPE "Status - Alarm"
|
|
--#SUMMARY "Auto-Config Failure"
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenAutoConfigEvents 1}
|
|
|
|
adGenAutoConfigTimeoutAlm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenAutoConfigTimeoutAlmSeverity,
|
|
adGenSlotProdPartNumber,
|
|
adGenSlotProdSwVersion,
|
|
adGenAutoConfigHostIPv4,
|
|
adGenAutoConfigHostIPv6,
|
|
adGenAutoConfigLastFailureFilename
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates the network element has exhausted all of
|
|
its application-layer retries when attempting to retrieve a file from
|
|
the server during the Auto-Config sequence."
|
|
--#TYPE "Status - Alarm"
|
|
--#SUMMARY "Auto-Config Timeout"
|
|
--#SEVERITY WARNING
|
|
--#GENERIC 6
|
|
--#CATEGORY "Informational Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= {adGenAutoConfigEvents 2}
|
|
|
|
END
|