ADTRAN-GENATM-MIB
|
|
|
|
-- TITLE: The ADTRAN ATM MIB
|
|
-- PRODUCT: Products supporting ATM
|
|
-- VERSION: 1.0
|
|
-- DATE: 12/28/11
|
|
-- AUTHOR: Gilbert Fernandez
|
|
-- STATUS: PRELIMINARY
|
|
|
|
-- This MIB defines the object identifier (OID) for the
|
|
-- ADTRAN SHARED CND SYSTEM MIB objects
|
|
|
|
-- HISTORY:
|
|
-- 12/28/11 glf STATUS: PRELIMINARY.
|
|
|
|
-- ******************************************************************************************
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
--==================================================================================================================
|
|
-- IMPORTS
|
|
--==================================================================================================================
|
|
IMPORTS
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
MODULE-IDENTITY,
|
|
Unsigned32,
|
|
Integer32,
|
|
Gauge32
|
|
FROM SNMPv2-SMI
|
|
sysName
|
|
FROM SNMPv2-MIB
|
|
OBJECT-GROUP,
|
|
NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
adGenAtm,
|
|
adGenAtmID
|
|
FROM ADTRAN-SHARED-CND-SYSTEM-MIB
|
|
adGenSlotInfoIndex
|
|
FROM ADTRAN-GENSLOT-MIB
|
|
;
|
|
|
|
--==================================================================================================================
|
|
-- MODULE IDENTITY
|
|
--==================================================================================================================
|
|
adGenAtmIdentity MODULE-IDENTITY
|
|
LAST-UPDATED "201112280000Z"
|
|
ORGANIZATION "Adtran, Inc."
|
|
CONTACT-INFO
|
|
"CND Tech Support
|
|
Postal: ADTRAN, Inc.
|
|
901 Explorer Blvd.
|
|
Huntsville, AL 35806
|
|
Tel: +1 800 726-8663
|
|
Fax: +1 256 963 6217
|
|
E-mail: support@adtran.com"
|
|
DESCRIPTION
|
|
"This MIB defines the objects for the genATM MIB."
|
|
REVISION "201112280000Z"
|
|
DESCRIPTION "Created"
|
|
::= { adGenAtmID 1 }
|
|
|
|
--==================================================================================================================
|
|
-- OBJECT IDENTIFIERS
|
|
--==================================================================================================================
|
|
|
|
adGenAtmStatus OBJECT IDENTIFIER ::= {adGenAtm 1}
|
|
adGenAtmBulkATM OBJECT IDENTIFIER ::= {adGenAtm 2}
|
|
|
|
--==================================================================================================================
|
|
-- ATM Status Tables
|
|
--==================================================================================================================
|
|
|
|
adGenAtmTotalCountStatusTable
|
|
OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenAtmTotalCountStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table contains instances that return the number of Vcls, Vpls, Vcccs, Vpccs, Interworked VCs, and Interworked VPs created"
|
|
::= { adGenAtmStatus 1 }
|
|
|
|
adGenAtmTotalCountStatusEntry OBJECT-TYPE
|
|
SYNTAX AdGenAtmTotalCountStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index is the slot number."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adGenAtmTotalCountStatusTable 1 }
|
|
|
|
AdGenAtmTotalCountStatusEntry ::=
|
|
SEQUENCE {
|
|
adGenAtmTotalCountVcl Integer32,
|
|
adGenAtmTotalCountVpl Integer32,
|
|
adGenAtmTotalCountVccc Integer32,
|
|
adGenAtmTotalCountVpcc Integer32,
|
|
adGenAtmTotalCountVcIntwk Integer32,
|
|
adGenAtmTotalCountVpIntwk Integer32
|
|
}
|
|
|
|
adGenAtmTotalCountVcl OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the total number of Vcls created"
|
|
::= { adGenAtmTotalCountStatusEntry 1 }
|
|
|
|
adGenAtmTotalCountVpl OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the total number of Vpls created"
|
|
::= { adGenAtmTotalCountStatusEntry 2 }
|
|
|
|
adGenAtmTotalCountVccc OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the total number of Vcccs created"
|
|
::= { adGenAtmTotalCountStatusEntry 3 }
|
|
|
|
adGenAtmTotalCountVpcc OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the total number of Vpccs created"
|
|
::= { adGenAtmTotalCountStatusEntry 4 }
|
|
|
|
adGenAtmTotalCountVcIntwk OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the total number of Interwork VCs created"
|
|
::= { adGenAtmTotalCountStatusEntry 5 }
|
|
|
|
adGenAtmTotalCountVpIntwk OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the total number of Interwork VPs created"
|
|
::= { adGenAtmTotalCountStatusEntry 6 }
|
|
|
|
--==================================================================================================================
|
|
-- Bulk ATM table operation
|
|
|
|
-- Request a TLV Instance to read the ATM Tables
|
|
-- adGenATMReserveInstanceBulkATMSlotTable lets you do that
|
|
|
|
-- All filters are defaulted to 0xffffffff until set by the user. The type is defaulted to 0.
|
|
-- Once the user obtains the instance number, the user must set the appropriate filters (type,slot1,port1,vpi1,vci1,node,slot2,port2,vpi2,vci2,stag,ctag)
|
|
-- The user must set the Type and at least one other filter order for the search to occur.
|
|
-- adGenAtmBulkATMFilterTable provides OIDs to do that.
|
|
|
|
-- Use the adGenAtmBulkATMSlotInstance OID in adGenAtmBulkATMFilterTable to build the filtered ATM Vccc, Vpcc, Vcl, Vpl, VcIntwk or VpIntwk entries
|
|
-- into TLV data for that instance based on the filters applied/associated with that instance.
|
|
|
|
-- All the above steps must be performed sequentially
|
|
-- The data stored in the TLV can be obtained by walking the OIDs in the TLV table (TLV-MIB).
|
|
--==================================================================================================================
|
|
|
|
--==================================================================================================================
|
|
-- Bulk ATM reserve instance
|
|
--==================================================================================================================
|
|
|
|
adGenAtmReserveInstanceBulkATMSlotTable
|
|
OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenAtmReserveInstanceBulkATMSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table contains instances that are created when there is a request to reserve a Bulk ATM instance"
|
|
::= { adGenAtmBulkATM 1 }
|
|
|
|
adGenAtmReserveInstanceBulkATMSlotEntry OBJECT-TYPE
|
|
SYNTAX AdGenAtmReserveInstanceBulkATMSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index is the slot number."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adGenAtmReserveInstanceBulkATMSlotTable 1 }
|
|
|
|
AdGenAtmReserveInstanceBulkATMSlotEntry ::=
|
|
SEQUENCE {
|
|
adGenAtmReserveInstanceBulkATMSlotInstance Integer32
|
|
}
|
|
|
|
adGenAtmReserveInstanceBulkATMSlotInstance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to index the Tlv table; each time this is called by slot it
|
|
creates an instance for that viewer"
|
|
::= { adGenAtmReserveInstanceBulkATMSlotEntry 1 }
|
|
|
|
--==================================================================================================================
|
|
-- The ATM Filter Table
|
|
--==================================================================================================================
|
|
|
|
adGenAtmBulkATMFilterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenAtmBulkATMFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table contains filters that can be applied on the requested instances"
|
|
::= { adGenAtmBulkATM 2 }
|
|
|
|
adGenAtmBulkATMFilterEntry OBJECT-TYPE
|
|
SYNTAX AdGenAtmBulkATMFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indexes are the slot and instance number"
|
|
INDEX { adGenSlotInfoIndex, adGenAtmBulkATMFilterInstance }
|
|
::= { adGenAtmBulkATMFilterTable 1 }
|
|
|
|
AdGenAtmBulkATMFilterEntry ::=
|
|
SEQUENCE {
|
|
adGenAtmBulkATMFilterInstance Integer32,
|
|
adGenAtmBulkATMFilterType INTEGER,
|
|
adGenAtmBulkATMFilterSlot1 Unsigned32,
|
|
adGenAtmBulkATMFilterPort1 Unsigned32,
|
|
adGenAtmBulkATMFilterVpi1 Unsigned32,
|
|
adGenAtmBulkATMFilterVci1 Unsigned32,
|
|
adGenAtmBulkATMFilterNode Unsigned32,
|
|
adGenAtmBulkATMFilterSlot2 Unsigned32,
|
|
adGenAtmBulkATMFilterPort2 Unsigned32,
|
|
adGenAtmBulkATMFilterVpi2 Unsigned32,
|
|
adGenAtmBulkATMFilterVci2 Unsigned32,
|
|
adGenAtmBulkATMFilterStag Unsigned32,
|
|
adGenAtmBulkATMFilterCtag Unsigned32,
|
|
adGenAtmBulkATMSlotInstance INTEGER
|
|
}
|
|
|
|
adGenAtmBulkATMFilterInstance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to index the Filter table by TLV Instance number."
|
|
::= { adGenAtmBulkATMFilterEntry 1 }
|
|
|
|
adGenAtmBulkATMFilterType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notspecified(0),
|
|
vccc(1),
|
|
vpcc(2),
|
|
vcl(3),
|
|
vpl(4),
|
|
vpintwk(5),
|
|
vcintwk(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the type filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 2 }
|
|
|
|
adGenAtmBulkATMFilterSlot1 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the slot endpoint1 filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 3 }
|
|
|
|
adGenAtmBulkATMFilterPort1 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the port endpoint1 filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 4 }
|
|
|
|
adGenAtmBulkATMFilterVpi1 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the vpi endpoint1 filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 5 }
|
|
|
|
adGenAtmBulkATMFilterVci1 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the vci endpoint1 filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 6 }
|
|
|
|
adGenAtmBulkATMFilterNode OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the node filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 7 }
|
|
|
|
adGenAtmBulkATMFilterSlot2 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the slot endpoint2 filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 8 }
|
|
|
|
adGenAtmBulkATMFilterPort2 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the port endpoint2 filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 9 }
|
|
|
|
adGenAtmBulkATMFilterVpi2 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the vpi endpoint2 filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 10 }
|
|
|
|
adGenAtmBulkATMFilterVci2 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the vci endpoint2 filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 11 }
|
|
|
|
adGenAtmBulkATMFilterStag OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the s-tag filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 12 }
|
|
|
|
adGenAtmBulkATMFilterCtag OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this to set the c-tag filter for a specific Bulk ATM instance of the Tlv table"
|
|
::= { adGenAtmBulkATMFilterEntry 13 }
|
|
|
|
adGenAtmBulkATMSlotInstance OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
updateinstance(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set this OID to 1 to update the instance with bulk ATM data based on filters.
|
|
A get on this OID always returns a 1."
|
|
::= { adGenAtmBulkATMFilterEntry 14 }
|
|
END
|
|
|