Observium_CE/mibs/adtran/ADTRAN-GEMINAX-MIB

184 lines
6.0 KiB
Plaintext

ADTRAN-GEMINAX-MIB
-- TITLE: The ADTRAN GEMINAX MIB
-- PRODUCT: Multiple
-- VERSION: 0.1
-- DATE: 2010/06/04
-- This MIB defines the object identifiers (OIDs) for the Geminax Max ADSL DSP recovery feature.
-- HISTORY:
-- Date By Descripition Rev
-- 2010/06/04 jeo First edition (0.1). STATUS: PRELIMINARY
--*********************************************************************************************************
DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE
FROM SNMPv2-SMI
OBJECT-GROUP
FROM SNMPv2-CONF
adGenSlotInfoIndex
FROM ADTRAN-GENSLOT-MIB
adGenGeminax,
adGenGeminaxID
FROM ADTRAN-SHARED-XDSL-MIB
;
--*********************************************************************************************************
adGenGeminaxMIB MODULE-IDENTITY
LAST-UPDATED "201006040000Z"
ORGANIZATION "ADTRAN, Inc."
CONTACT-INFO
"Web: http://www.adtran.com
E-mail: support@adtran.com"
DESCRIPTION
"This is the MIB module that describes
Geminax recovery option settings"
::= { adGenGeminaxID 1 }
-- OBJECT IDENTIFIERS
adGenGeminaxMax OBJECT IDENTIFIER ::= { adGenGeminax 1 }
-- *************************************************************************
-- test
-- ************************************************************************
adGenGeminaxDiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenGeminaxDiagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information on the Lantiq (Infineon)
GeminaxMax DSP. Each entry reflects a required
parameter or action required to perform either the SELT
or DELT diagnostic test. "
::= { adGenGeminaxMax 1 }
adGenGeminaxDiagEntry OBJECT-TYPE
SYNTAX AdGenGeminaxDiagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains configuration parameters for the GeminaxMax DSP.
The entries are used to configure the recovery option settings."
INDEX { adGenSlotInfoIndex }
::= { adGenGeminaxDiagTable 1 }
AdGenGeminaxDiagEntry ::=
SEQUENCE {
adGenGeminaxErrorClassECF INTEGER,
adGenGeminaxErrorClassA INTEGER,
adGenGeminaxErrorClassB INTEGER,
adGenGeminaxErrorClassC INTEGER,
adGenGeminaxErrorClassD INTEGER,
adGenGeminaxErrorClassE INTEGER
}
adGenGeminaxErrorClassECF OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
logOnly(2),
softReset(3),
hardReset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the action to be taken when a Class ECF error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard reset"
::= { adGenGeminaxDiagEntry 1 }
adGenGeminaxErrorClassA OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
logOnly(2),
softReset(3),
hardReset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the action to be taken when a Class A error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard reset"
::= { adGenGeminaxDiagEntry 2 }
adGenGeminaxErrorClassB OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
logOnly(2),
softReset(3),
hardReset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the action to be taken when a Class B error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard reset"
::= { adGenGeminaxDiagEntry 3 }
adGenGeminaxErrorClassC OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
logOnly(2),
softReset(3),
hardReset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the action to be taken when a Class C error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard reset"
::= { adGenGeminaxDiagEntry 4 }
adGenGeminaxErrorClassD OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
logOnly(2),
softReset(3),
hardReset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the action to be taken when a Class D error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard reset"
::= { adGenGeminaxDiagEntry 5 }
adGenGeminaxErrorClassE OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
logOnly(2),
softReset(3),
hardReset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the action to be taken when a Class E error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard reset"
::= { adGenGeminaxDiagEntry 6 }
END