184 lines
6.0 KiB
Plaintext
184 lines
6.0 KiB
Plaintext
ADTRAN-GEMINAX-MIB
|
|
-- TITLE: The ADTRAN GEMINAX MIB
|
|
-- PRODUCT: Multiple
|
|
-- VERSION: 0.1
|
|
-- DATE: 2010/06/04
|
|
|
|
-- This MIB defines the object identifiers (OIDs) for the Geminax Max ADSL DSP recovery feature.
|
|
|
|
-- HISTORY:
|
|
-- Date By Descripition Rev
|
|
-- 2010/06/04 jeo First edition (0.1). STATUS: PRELIMINARY
|
|
|
|
--*********************************************************************************************************
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
adGenSlotInfoIndex
|
|
FROM ADTRAN-GENSLOT-MIB
|
|
adGenGeminax,
|
|
adGenGeminaxID
|
|
FROM ADTRAN-SHARED-XDSL-MIB
|
|
;
|
|
|
|
--*********************************************************************************************************
|
|
adGenGeminaxMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201006040000Z"
|
|
ORGANIZATION "ADTRAN, Inc."
|
|
CONTACT-INFO
|
|
"Web: http://www.adtran.com
|
|
E-mail: support@adtran.com"
|
|
DESCRIPTION
|
|
"This is the MIB module that describes
|
|
Geminax recovery option settings"
|
|
::= { adGenGeminaxID 1 }
|
|
|
|
-- OBJECT IDENTIFIERS
|
|
adGenGeminaxMax OBJECT IDENTIFIER ::= { adGenGeminax 1 }
|
|
|
|
-- *************************************************************************
|
|
-- test
|
|
-- ************************************************************************
|
|
adGenGeminaxDiagTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenGeminaxDiagEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information on the Lantiq (Infineon)
|
|
GeminaxMax DSP. Each entry reflects a required
|
|
parameter or action required to perform either the SELT
|
|
or DELT diagnostic test. "
|
|
::= { adGenGeminaxMax 1 }
|
|
|
|
|
|
adGenGeminaxDiagEntry OBJECT-TYPE
|
|
SYNTAX AdGenGeminaxDiagEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table contains configuration parameters for the GeminaxMax DSP.
|
|
The entries are used to configure the recovery option settings."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adGenGeminaxDiagTable 1 }
|
|
|
|
AdGenGeminaxDiagEntry ::=
|
|
SEQUENCE {
|
|
adGenGeminaxErrorClassECF INTEGER,
|
|
adGenGeminaxErrorClassA INTEGER,
|
|
adGenGeminaxErrorClassB INTEGER,
|
|
adGenGeminaxErrorClassC INTEGER,
|
|
adGenGeminaxErrorClassD INTEGER,
|
|
adGenGeminaxErrorClassE INTEGER
|
|
}
|
|
|
|
|
|
adGenGeminaxErrorClassECF OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
logOnly(2),
|
|
softReset(3),
|
|
hardReset(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the action to be taken when a Class ECF error occurs. The following settings are allowed:
|
|
disabled(1) - do nothing,
|
|
logOnly(2) - log the event,
|
|
softReset(3) - trigger a soft reset,
|
|
hardReset(4) - trigger a hard reset"
|
|
::= { adGenGeminaxDiagEntry 1 }
|
|
|
|
adGenGeminaxErrorClassA OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
logOnly(2),
|
|
softReset(3),
|
|
hardReset(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the action to be taken when a Class A error occurs. The following settings are allowed:
|
|
disabled(1) - do nothing,
|
|
logOnly(2) - log the event,
|
|
softReset(3) - trigger a soft reset,
|
|
hardReset(4) - trigger a hard reset"
|
|
::= { adGenGeminaxDiagEntry 2 }
|
|
|
|
adGenGeminaxErrorClassB OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
logOnly(2),
|
|
softReset(3),
|
|
hardReset(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the action to be taken when a Class B error occurs. The following settings are allowed:
|
|
disabled(1) - do nothing,
|
|
logOnly(2) - log the event,
|
|
softReset(3) - trigger a soft reset,
|
|
hardReset(4) - trigger a hard reset"
|
|
::= { adGenGeminaxDiagEntry 3 }
|
|
|
|
adGenGeminaxErrorClassC OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
logOnly(2),
|
|
softReset(3),
|
|
hardReset(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the action to be taken when a Class C error occurs. The following settings are allowed:
|
|
disabled(1) - do nothing,
|
|
logOnly(2) - log the event,
|
|
softReset(3) - trigger a soft reset,
|
|
hardReset(4) - trigger a hard reset"
|
|
::= { adGenGeminaxDiagEntry 4 }
|
|
|
|
adGenGeminaxErrorClassD OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
logOnly(2),
|
|
softReset(3),
|
|
hardReset(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the action to be taken when a Class D error occurs. The following settings are allowed:
|
|
disabled(1) - do nothing,
|
|
logOnly(2) - log the event,
|
|
softReset(3) - trigger a soft reset,
|
|
hardReset(4) - trigger a hard reset"
|
|
::= { adGenGeminaxDiagEntry 5 }
|
|
|
|
adGenGeminaxErrorClassE OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
logOnly(2),
|
|
softReset(3),
|
|
hardReset(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the action to be taken when a Class E error occurs. The following settings are allowed:
|
|
disabled(1) - do nothing,
|
|
logOnly(2) - log the event,
|
|
softReset(3) - trigger a soft reset,
|
|
hardReset(4) - trigger a hard reset"
|
|
::= { adGenGeminaxDiagEntry 6 }
|
|
|
|
|
|
|
|
END
|