Observium_CE/mibs/adtran/ADTRAN-AOS-IF

238 lines
7.2 KiB
Plaintext

ADTRAN-AOS-IF DEFINITIONS ::= BEGIN
IMPORTS
Counter64, Gauge32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
CounterBasedGauge64
FROM HCNUM-TC
DisplayString
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
InterfaceIndex, ifIndex
FROM IF-MIB
adIdentity
FROM ADTRAN-MIB
adGenAOSConformance, adGenAOSRouter
FROM ADTRAN-AOS;
adGenAOSIfMib MODULE-IDENTITY
LAST-UPDATED "201803080000Z" -- March 08, 2018 / YYYYMMDDHHMMZ
ORGANIZATION "ADTRAN, Inc."
CONTACT-INFO
"Technical Support Dept.
Postal: ADTRAN, Inc.
901 Explorer Blvdr
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"This MIB module contains statistics of network interfaces required to monitor and analyze the traffic passing through them."
REVISION "201803080000Z" -- March 08, 2018 / YYYYMMDDHHMMZ
DESCRIPTION
"Invalid CE-VLAN-ID Drops Counter added."
REVISION "201708300000Z" -- August 30, 2017 / YYYYMMDDHHMMZ
DESCRIPTION
"First Draft of ADTRAN-AOS-IF MIB module."
::= { adIdentity 10000 53 2 4 }
adGenAOSIf OBJECT IDENTIFIER ::= { adGenAOSRouter 4 }
adGenAOSIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenAOSIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing all interface statistics with their respective indices in accordance with the IF-MIB."
::= { adGenAOSIf 1 }
adGenAOSIfEntry OBJECT-TYPE
SYNTAX AdGenAOSIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The parameters for interfaces."
INDEX { ifIndex }
::= { adGenAOSIfTable 1 }
AdGenAOSIfEntry ::=
SEQUENCE {
adGenAOSIfName DisplayString,
adGenAOSInOctets30s CounterBasedGauge64,
adGenAOSOutOctets30s CounterBasedGauge64,
adGenAOSInPackets30s CounterBasedGauge64,
adGenAOSOutPackets30s CounterBasedGauge64,
adGenAOSInOctets5m CounterBasedGauge64,
adGenAOSOutOctets5m CounterBasedGauge64,
adGenAOSInPackets5m CounterBasedGauge64,
adGenAOSOutPackets5m CounterBasedGauge64,
adGenAOSInUndersizedFrames Gauge32,
adGenAOSInOversizedFrames Gauge32,
adGenAOSInFramesFCS Gauge32,
adGenAOSInInvalidCeVlanIdDrops Counter64
}
adGenAOSIfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the
interface. This string should include the name of the
manufacturer, the product name and the version of the
interface hardware/software."
::= { adGenAOSIfEntry 1 }
adGenAOSInOctets30s OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average of received octets within 30s"
::= { adGenAOSIfEntry 2 }
adGenAOSOutOctets30s OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average of transmitted octets within 30s"
::= { adGenAOSIfEntry 3 }
adGenAOSInPackets30s OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average of received frames within 30s"
::= { adGenAOSIfEntry 4 }
adGenAOSOutPackets30s OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average of transmitted frames within 30s"
::= { adGenAOSIfEntry 5 }
adGenAOSInOctets5m OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average of received octets within 300s"
::= { adGenAOSIfEntry 6 }
adGenAOSOutOctets5m OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average of transmitted octets within 300s"
::= { adGenAOSIfEntry 7 }
adGenAOSInPackets5m OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average of received frames within 300s"
::= { adGenAOSIfEntry 8 }
adGenAOSOutPackets5m OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average of transmitted frames within 300s"
::= { adGenAOSIfEntry 9 }
adGenAOSInUndersizedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received frames that is smaller than 64Bytes/Octets."
::= { adGenAOSIfEntry 10 }
adGenAOSInOversizedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received frames that exceed the configured MTU size."
::= { adGenAOSIfEntry 11 }
adGenAOSInFramesFCS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received frames with CRC failure or defect data packets based on collision."
::= { adGenAOSIfEntry 12 }
adGenAOSInInvalidCeVlanIdDrops OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames dropped which were received with an Invalid CE-VLAN-ID."
::= { adGenAOSIfEntry 13}
------------------------------------------------------------
-- Conformance information
--
adGenAOSIfConformance OBJECT IDENTIFIER
::= { adGenAOSConformance 26 }
adGenAOSIfGroups OBJECT IDENTIFIER
::= { adGenAOSIfConformance 1 }
adGenAOSIfCompliances OBJECT IDENTIFIER
::= { adGenAOSIfConformance 2 }
-- Compliance statements
--
-- Full compliance statement
adGenAOSIfCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which implement
the adGenAOSIf MIB."
MODULE -- this module
GROUP adGenAOSIfStatsGroup
DESCRIPTION
"This optional group defines the notification generated by events."
::= { adGenAOSIfCompliances 1 }
adGenAOSIfStatsGroup OBJECT-GROUP
OBJECTS {
adGenAOSInOctets30s,
adGenAOSOutOctets30s,
adGenAOSInPackets30s,
adGenAOSOutPackets30s,
adGenAOSInOctets5m,
adGenAOSOutOctets5m,
adGenAOSInPackets5m,
adGenAOSOutPackets5m,
adGenAOSInUndersizedFrames,
adGenAOSInOversizedFrames,
adGenAOSInFramesFCS,
adGenAOSInInvalidCeVlanIdDrops
}
STATUS current
DESCRIPTION
"A collection of objects that indicate the octet and packet statistics."
::= { adGenAOSIfGroups 1 }
END