-- Copyright 1995 by 3Com Corporation. All rights reserved.
|
|
-- MIB file name: a3Com-ipx
|
|
-- available in these 3Com devices: NETBuilder bridge/routers
|
|
-- For support or more info, check 3Com's web page at http://www.3com.com
|
|
|
|
--
|
|
--
|
|
-- This MIB is for 3Com intermediate systems that support IPX
|
|
--
|
|
-- The 3Com Enterprise Products Proprietary MIB Extensions
|
|
--
|
|
-- Copyright 3Com Corporation, 1993. All rights reserved.
|
|
--
|
|
-- changes FOR software release 7.0 (r2 of MIB):
|
|
-- 20-oct-93: kxy added support for IPX WAN (incremental update) feature
|
|
-- 13-dec-93: kxy deprecated a3ipxRipControlMapOpt
|
|
-- 20-dec-93: ehk returned a3ipxRipControlMapOpt
|
|
--
|
|
-- changes for software release 7.1 (r3 of MIB):
|
|
-- 01-apr-94: kxy added a3ipxPreferredSvrTable
|
|
--
|
|
--
|
|
--
|
|
-- changes for software release 8.0 (r4 of MIB):
|
|
-- 20-may-94: kxy changed a3ipxSmdsGaAddress such that
|
|
-- all zeros is returned if no SMDS address has
|
|
-- been assigned.
|
|
-- 22-may-94: kxy updated mib to conform to ipx_changes.
|
|
-- Specifically: o ipx*Control objects were made port specific
|
|
-- o ipxRipControl was split into talk ctl and
|
|
-- listen ctl
|
|
-- o control over Sap talk and listen was added
|
|
-- o control over x25 queue size, VC limit and
|
|
-- VC timer was removed.
|
|
-- 24-may-94: dch : a3ipxRipUpdateTime and a3ipxSapUpdateTime to be
|
|
-- port-specific. deprecated a3ipxUpdateTime.
|
|
--
|
|
-- 25-may-94: kxy now, a3ipxRouteTable only displays the primary
|
|
-- routes. Also, when routes are added, it will accept only
|
|
-- primary routes.
|
|
--
|
|
-- 07-jul-94: kgo : to support IPX DOD spoofing, added new table,
|
|
-- a3ipxSpoofCtlTable (a3ComIPX 11) and its component
|
|
-- objects.
|
|
--
|
|
-- 07-jul-94: dch : moved IpxWan/NoIpxWan to be under -ipx CONTrol,
|
|
-- instead of -nrip CONTrol, add HoldTimeMultiplier
|
|
-- under -nrip and -sap.
|
|
--
|
|
-- 29-jul-94: dch : added a3ipxX25configProfId for -IPX X25PROFileid
|
|
-- also rename a3ipxRipHoldTimeMultiple to
|
|
-- a3ipxRipHoldTimeFactor and a3ipxSapHoldTimeMultiple
|
|
-- to a3ipxSapHoldTimeFactor
|
|
-- 10-nov-94: dch : a3ipxRipHoldTimeFactor and a3ipxSapHoldTimeFactor
|
|
-- now have range (1..24) and default 3.
|
|
--
|
|
-- changes for software release 8.2 (r5 of MIB):
|
|
-- 20-mar-95: kxy: Added a3ipxDefMetricHops and a3ipxDefMetricTicks to
|
|
-- a3ipxPortconfigTable. This is needed to support the
|
|
-- IPX Default Route feature. Also added a3ipxRipCtl and
|
|
-- a3ipxSapCtl, and deprecated a3ipxSapCtlTalk,
|
|
-- a3ipxSapCtlListen, a3ipxRipCtlTalk, and
|
|
-- a3ipxRipCtlListen
|
|
--
|
|
|
|
A3Com-IPX-r5-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises
|
|
FROM RFC1155-SMI
|
|
PhysAddress, DisplayString
|
|
FROM RFC1213-MIB
|
|
MacAddress
|
|
FROM RFC1286-MIB
|
|
OBJECT-TYPE
|
|
FROM RFC-1212;
|
|
|
|
--
|
|
-- This MIB is for 3Com products that implement IPX routing
|
|
--
|
|
|
|
a3Com OBJECT IDENTIFIER ::= { enterprises 43 }
|
|
brouterMIB OBJECT IDENTIFIER ::= { a3Com 2 }
|
|
a3ComIPX OBJECT IDENTIFIER ::= { brouterMIB 7 }
|
|
|
|
SMDSAddress ::= OCTET STRING (SIZE (8))
|
|
-- the 60-bit SMDS address, preceded by 4 bits with the
|
|
-- following values:
|
|
-- "1100" when representing an individual address
|
|
-- "1110" when representing a group address
|
|
|
|
RowStatus ::= INTEGER {
|
|
active(1),
|
|
notInService(2),
|
|
notReady(3),
|
|
createAndGo(4),
|
|
createAndWait(5),
|
|
destroy(6)
|
|
}
|
|
|
|
--This data type, which has the same semantics as the RowStatus
|
|
--textual convention used in SNMPv2, is used to add and
|
|
--delete entries from a table.
|
|
--
|
|
--The tables in this MIB allow a subset of the functionality
|
|
--provided by the RowStatus textual convention. In particular
|
|
--row creation is allowed using only the createAndGo method.
|
|
--
|
|
--That is, when adding entries to this table, this object
|
|
--must be set to createAndGo(4). The instance identifier
|
|
--for this object will define the values of the columns
|
|
--that make up the index.
|
|
--
|
|
--In the same PDU, the appropriate remaining columns
|
|
--of that row must be set as well. The agent
|
|
--will immediately set the value of this object to
|
|
--active(1) if the row is correct. If not, the agent
|
|
--will refuse the SET request and return an
|
|
--error code.
|
|
--
|
|
--To modify an existing entry, it must be removed
|
|
--and another entry with the desired changes added.
|
|
--
|
|
--To remove an entry, set the value of this object
|
|
--to destroy(6).
|
|
|
|
|
|
|
|
--
|
|
-- The first group in the MIB is for general, non
|
|
-- port-specific IPX related objects
|
|
--
|
|
a3ipxGeneral OBJECT IDENTIFIER ::= { a3ComIPX 1 }
|
|
a3ipxControl OBJECT IDENTIFIER ::= { a3ipxGeneral 7 }
|
|
|
|
--
|
|
-- IPX Network Number
|
|
--
|
|
|
|
IPXNET ::= OCTET STRING (SIZE(4))
|
|
|
|
|
|
|
|
a3ipxRouteControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"If this object is set to enabled(1), then IPX routing
|
|
is enabled. If this object is set to disabled(2),
|
|
then IPX routing is disabled. Note, if this is disabled(2),
|
|
then RIP is disabled as well (for all Ports).
|
|
|
|
If this is set to disabled(2), then all dynamic routing
|
|
entries will be removed. All entries in the server
|
|
table will be removed as well.
|
|
|
|
NOTE: for NETBuilders running sw version 8.0 and greater,
|
|
this object is no longer supported. a3ipxControlTable
|
|
has replaced its functionality."
|
|
DEFVAL { disabled }
|
|
::= { a3ipxGeneral 1 }
|
|
|
|
a3ipxWanBcastControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"If this object is enabled(1), then the IPX router
|
|
makes copies of all received WAN broadcast packets
|
|
and forwards them to all ports other than the one
|
|
on which that packet was received.
|
|
|
|
NOTE: for NETBuilders running sw version 8.0 and greater,
|
|
this object is no longer supported. a3ipxControlTable
|
|
has replaced its functionality."
|
|
DEFVAL { enabled }
|
|
::= { a3ipxGeneral 2 }
|
|
|
|
a3ipxUpdateTime OBJECT-TYPE
|
|
SYNTAX INTEGER (10..65535)
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This parameter specifies how often the router sends both
|
|
RIP and SAP regular updates to exhange routing and service
|
|
information. This parameter is defined in units of seconds.
|
|
|
|
NOTE: for NETBuilders running sw version 8.0 and greater,
|
|
this object is no longer supported. a3ipxRipUpdateTime
|
|
and a3ipxSapUpdateTime have replaced its functionality."
|
|
DEFVAL { 60 }
|
|
::= { a3ipxGeneral 3 }
|
|
|
|
a3ipxFlushRipSap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
rip (2),
|
|
sap (3),
|
|
both (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to remove dynamic routing and
|
|
or sap entries quickly and efficiently. Setting this
|
|
object to rip (2) causes all dynamically entered routes
|
|
to be removed from a3ipxRouteTable.
|
|
|
|
If this object is set to sap (3), all dynamicaly learned
|
|
sap entries will be removed from a3ipxServerTable.
|
|
|
|
If this object is set to both (4), all dynamic entries
|
|
will be removed from both the routing table (a3ipxRouteTable)
|
|
and the sap table (a3ipxServerTable).
|
|
|
|
If a GET REQUEST is received for this object, other (1)
|
|
will be returned. Setting this object to other (1) will have
|
|
no effect on any routing or sap entries."
|
|
::= { a3ipxGeneral 4 }
|
|
|
|
a3ipxInternalNet OBJECT-TYPE
|
|
SYNTAX IPXNET
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object represents the router's internal network
|
|
number. This is used during IPX WAN negotiation and is
|
|
the basis on which the MASTER/SLAVE selection is made.
|
|
The router with the lowest internal network number
|
|
becomes the SLAVE of the link."
|
|
::= { a3ipxGeneral 5 }
|
|
|
|
a3ipxRouterName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..48))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object specifies the router's symbolic name and
|
|
is used during IPX WAN negotiations to build RIP/SAP
|
|
Information Request/Response packets."
|
|
::= { a3ipxGeneral 6 }
|
|
|
|
--
|
|
-- This table specifies port specific 'control' oriented IPX parameters
|
|
--
|
|
|
|
a3ipxControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ipxControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of port-specific IPX control parmeters.
|
|
This table is used currently to control ipx routing,
|
|
WAN broadcasts, and WAN checksums."
|
|
::= { a3ipxControl 1 }
|
|
|
|
a3ipxControlEntry OBJECT-TYPE
|
|
SYNTAX A3ipxControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry in this table applies control over
|
|
a seperate port."
|
|
INDEX { a3ipxControlPort }
|
|
::= { a3ipxControlTable 1 }
|
|
|
|
A3ipxControlEntry ::=
|
|
SEQUENCE {
|
|
a3ipxControlPort INTEGER,
|
|
a3ipxControlRoute INTEGER,
|
|
a3ipxControlWanBcast INTEGER,
|
|
a3ipxControlChecksum INTEGER,
|
|
a3ipxControlWanOpt INTEGER
|
|
}
|
|
|
|
a3ipxControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX port to which this entry applies."
|
|
::= { a3ipxControlEntry 1 }
|
|
|
|
a3ipxControlRoute OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this object is set to enabled(1), then IPX routing
|
|
is enabled. If this object is set to disabled(2),
|
|
then IPX routing is disabled. Note, if this is disabled(2),
|
|
then RIP is disabled as well (for this Port).
|
|
|
|
If this is set to disabled(2), then all dynamic routing
|
|
entries will be removed. All entries in the server
|
|
table will be removed as well."
|
|
DEFVAL { disabled }
|
|
::= { a3ipxControlEntry 2 }
|
|
|
|
a3ipxControlWanBcast OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this object is enabled(1), then the IPX router
|
|
makes copies of all received WAN broadcast packets
|
|
and forwards them to all ports other than the one
|
|
on which that packet was received."
|
|
DEFVAL { enabled }
|
|
::= { a3ipxControlEntry 3 }
|
|
|
|
a3ipxControlChecksum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this object is set to enabled(1), Checksum will be
|
|
generated and checked on IPX packet over WAN."
|
|
DEFVAL { disabled }
|
|
::= { a3ipxControlEntry 4 }
|
|
|
|
a3ipxControlWanOpt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wan (1),
|
|
noWan(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to enable or disable the IPX WAN
|
|
feature on a specific port. IPX WAN is the protocol
|
|
Novell IPX uses to exchange necessary router to
|
|
router information prior to exchanging IPX RIP and
|
|
SAP information over various WAN links. If this object
|
|
has the value wan(1), the feature is enabled. Otherwise
|
|
it is disabled. This object applies only to WAN ports.
|
|
For software release 7.0, only ports supporting PPP offer
|
|
this feature."
|
|
DEFVAL { noWan }
|
|
::= { a3ipxControlEntry 5 }
|
|
|
|
|
|
--
|
|
-- This next table controls RIP-IPX parameters
|
|
--
|
|
|
|
a3ipxRipControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ipxRipControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of RIP Control parameter entries"
|
|
::= { a3ComIPX 2 }
|
|
|
|
a3ipxRipControlEntry OBJECT-TYPE
|
|
SYNTAX A3ipxRipControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of parameters that determin how IPX updates
|
|
its routing table."
|
|
INDEX { a3ipxRipControlPort }
|
|
::= { a3ipxRipControlTable 1 }
|
|
|
|
A3ipxRipControlEntry ::=
|
|
SEQUENCE {
|
|
a3ipxRipControlPort INTEGER,
|
|
a3ipxRipControlSwitch INTEGER,
|
|
a3ipxRipControlTrigger INTEGER,
|
|
a3ipxRipControlPoison INTEGER,
|
|
a3ipxRipControlMapOpt INTEGER,
|
|
a3ipxRipControlWanOpt INTEGER,
|
|
a3ipxRipControlPerRip INTEGER,
|
|
a3ipxRipControlPerSap INTEGER,
|
|
a3ipxRipControlTalk INTEGER,
|
|
a3ipxRipControlListen INTEGER,
|
|
a3ipxSapControlTalk INTEGER,
|
|
a3ipxSapControlListen INTEGER,
|
|
a3ipxRipCtl INTEGER,
|
|
a3ipxSapCtl INTEGER
|
|
}
|
|
|
|
a3ipxRipControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX port to which this entry applies."
|
|
::= { a3ipxRipControlEntry 1 }
|
|
|
|
a3ipxRipControlSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"If this object is set to enabled(1), IPX RIP exchanges
|
|
RIP information with its neighbors and maintains the
|
|
routing table dynamically. If this object is set to
|
|
disabled(2), dynamic learning is stopped and no
|
|
RIP updates are generated.
|
|
|
|
NOTE: this object is no longer supported by NETBuilders
|
|
running sw version 8.0 and greater. The objects
|
|
a3ipxRipControlTalk, a3ipxRipControlListen,
|
|
a3ipxSapControlTalk, and a3ipxSapControlListen have
|
|
replaced this object's functionality."
|
|
DEFVAL { enabled }
|
|
::= { a3ipxRipControlEntry 2 }
|
|
|
|
a3ipxRipControlTrigger OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this object is set to enabled(1), triggered
|
|
responses are sent when the network topology changes,
|
|
allowing the network to calculate potentially better
|
|
routes. If this object is disabled(2), topology
|
|
change responses are not sent immediately, but are
|
|
included in the regular updates."
|
|
DEFVAL { enabled }
|
|
::= { a3ipxRipControlEntry 3 }
|
|
|
|
a3ipxRipControlPoison OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this object is set to enabled(1), Split Horizon with
|
|
Poison Reverse is performed. If this object is set to
|
|
disabled(2), the router omits routes learned from one
|
|
neighbor in regular updates sent to that neighbor."
|
|
DEFVAL { disabled }
|
|
::= { a3ipxRipControlEntry 4 }
|
|
|
|
a3ipxRipControlMapOpt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oldNbrMap(1),
|
|
newNbrMap(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"X.25 addresses and Frame Relay DLCIs can be mapped in
|
|
two different ways: by using IPX network numbers
|
|
as previously implemented (OldNbrMap) or by using the
|
|
Ethernet address of the remote NETBuilder currently
|
|
implemented (NewNbrMap). This option is set to
|
|
NewNbrMap by default, but OldNbrMap should be selected
|
|
to interoperate with a neighbor running earlier than
|
|
5.0 bridge/router software."
|
|
DEFVAL { newNbrMap }
|
|
::= { a3ipxRipControlEntry 5 }
|
|
|
|
a3ipxRipControlWanOpt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wan (1),
|
|
noWan(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object is used to enable or disable the IPX WAN
|
|
feature on a specific port. IPX WAN is the protocol
|
|
Novell IPX uses to exchange necessary router to
|
|
router information prior to exchanging IPX RIP and
|
|
SAP information over various WAN links. If this object
|
|
has the value wan(1), the feature is enabled. Otherwise
|
|
it is disabled. This object applies only to WAN ports.
|
|
For software release 7.0, only ports supporting PPP offer
|
|
this feature."
|
|
DEFVAL { noWan }
|
|
::= { a3ipxRipControlEntry 6 }
|
|
|
|
a3ipxRipControlPerRip OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
periodicRip (1),
|
|
nonPeriodicRip (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to specify how this router
|
|
generates IPX RIP updates. If this object is set
|
|
to periodicRip(1), the router will generate RIP
|
|
updates periodically. If this object is set to
|
|
nonPeriodicRip(2), the router will generate
|
|
incremental updates. When selecting this option,
|
|
make sure that all participating routers use
|
|
the same option."
|
|
DEFVAL { periodicRip }
|
|
::= { a3ipxRipControlEntry 7 }
|
|
|
|
a3ipxRipControlPerSap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
periodicSap (1),
|
|
nonPeriodicSap (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to specify how this router
|
|
generates IPX SAP updates. If this object is set
|
|
to periodicSap(1), the router will generate SAP
|
|
updates periodically. If this object is set to
|
|
nonPeriodicSap(2), the router will generate
|
|
incremental updates. When selecting this option,
|
|
make sure that all participating routers use
|
|
the same option."
|
|
DEFVAL{ periodicSap }
|
|
::= { a3ipxRipControlEntry 8 }
|
|
|
|
a3ipxRipControlTalk OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object controls the transmission of IPX RIP
|
|
updates on this port. If enabled, IPX RIP updates
|
|
are sent. If disabled, they are not sent."
|
|
DEFVAL { enabled }
|
|
::= { a3ipxRipControlEntry 9 }
|
|
|
|
a3ipxRipControlListen OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object determines if IPX RIP updates are accepted
|
|
over this port. If this object is enabled(1), then the
|
|
IPX router listens to the incoming RIP updates.
|
|
If this object is set to disabled(2), then the IPX
|
|
router does not listen for IPX RIP updates."
|
|
DEFVAL { enabled }
|
|
::= { a3ipxRipControlEntry 10 }
|
|
|
|
a3ipxSapControlTalk OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object controls the transmission of IPX SAP
|
|
updates on this port. If enabled, IPX SAP updates
|
|
are sent. If disabled, they are not sent."
|
|
DEFVAL { enabled }
|
|
::= { a3ipxRipControlEntry 11 }
|
|
|
|
a3ipxSapControlListen OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object determines if IPX SAP updates are accepted
|
|
over this port. If this object is enabled(1), then the
|
|
IPX router listens to the incoming SAP updates.
|
|
If this object is set to disabled(2), then the IPX
|
|
router does not listen for IPX SAP updates."
|
|
DEFVAL { enabled }
|
|
::= { a3ipxRipControlEntry 12 }
|
|
|
|
a3ipxRipCtl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
talkListen (1),
|
|
talkNoListen (2),
|
|
noTalkListen (3),
|
|
noTalkNoListen (4),
|
|
auto (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { a3ipxRipControlEntry 13 }
|
|
|
|
a3ipxSapCtl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
talkListen (1),
|
|
talkNoListen (2),
|
|
noTalkListen (3),
|
|
noTalkNoListen (4),
|
|
auto (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { a3ipxRipControlEntry 14 }
|
|
|
|
|
|
|
|
--
|
|
-- This next table contains a list of IPX addresses that
|
|
-- are reachable across a wide area network
|
|
--
|
|
|
|
a3ipxWaAddrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ipxWaAddrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of IPX entities reachable across a
|
|
wide area network."
|
|
::= { a3ComIPX 3 }
|
|
|
|
a3ipxWaAddrEntry OBJECT-TYPE
|
|
SYNTAX A3ipxWaAddrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry contains the WAN Address of an IPX
|
|
entity. Each entry also contains the IPX port
|
|
over which the entity can be reached."
|
|
INDEX { a3ipxWaAddrEthAddress }
|
|
::= { a3ipxWaAddrTable 1 }
|
|
|
|
A3ipxWaAddrEntry ::= SEQUENCE {
|
|
a3ipxWaAddrEthAddress MacAddress,
|
|
a3ipxWaAddrPort INTEGER,
|
|
a3ipxWaAddrDLType INTEGER,
|
|
a3ipxWaAddrDLAddress PhysAddress,
|
|
a3ipxWaAddrStatus RowStatus
|
|
}
|
|
|
|
a3ipxWaAddrEthAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Ethernet address (IPX Node ID) of a remote IPX entity."
|
|
::= { a3ipxWaAddrEntry 1 }
|
|
|
|
a3ipxWaAddrPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX port through which the IPX entity identified
|
|
by a3ipxWaAddrEthAddress can be reached."
|
|
::= { a3ipxWaAddrEntry 2 }
|
|
|
|
a3ipxWaAddrDLType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
x25 (1),
|
|
frameRelay (2),
|
|
smds (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of address that is returned by
|
|
a3ipxWaAddrDLAddress."
|
|
::= { a3ipxWaAddrEntry 3 }
|
|
|
|
a3ipxWaAddrDLAddress OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The WAN address that is used to reach the IPX entity
|
|
corresponding to this table entry."
|
|
::= { a3ipxWaAddrEntry 4 }
|
|
|
|
a3ipxWaAddrStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to add and delete entries
|
|
in this table. See the notes describing
|
|
RowStatus at the beginning of this MIB."
|
|
::= { a3ipxWaAddrEntry 5 }
|
|
|
|
--
|
|
-- This next table lists the IPX networks attached to an IPX port
|
|
--
|
|
|
|
a3ipxAttachedNetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ipxAttachedNetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of the IPX Network Numbers attached to an IPX port."
|
|
::= { a3ComIPX 4 }
|
|
|
|
a3ipxAttachedNetEntry OBJECT-TYPE
|
|
SYNTAX A3ipxAttachedNetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry specifies an IPX network number, assigns
|
|
it to a port, and specifies the header format to
|
|
be used when sending IPX packets to that network.
|
|
On Ethernet ports, up to four different IPX Network
|
|
Numbers may be specified, of which only one may be
|
|
primary. On serial ports, only one IPX Network Number
|
|
may be configured. The header format assigned to a
|
|
serial port is irrelevant. The header format is
|
|
determined, instead, by the owner of the port (X25, ppp,
|
|
etc.)
|
|
|
|
If an attached network number is removed, the server
|
|
entries that are reachable through that network
|
|
will be removed. All routing entries that are
|
|
reachable through that network are removed as well."
|
|
INDEX { a3ipxAttachedNetNumber }
|
|
::= { a3ipxAttachedNetTable 1 }
|
|
|
|
A3ipxAttachedNetEntry ::= SEQUENCE {
|
|
a3ipxAttachedNetNumber IPXNET,
|
|
a3ipxAttachedNetPort INTEGER,
|
|
a3ipxAttachedNetFormat INTEGER,
|
|
a3ipxAttachedNetType INTEGER,
|
|
a3ipxAttachedNetOperState INTEGER,
|
|
a3ipxAttachedNetStatus RowStatus
|
|
}
|
|
|
|
a3ipxAttachedNetNumber OBJECT-TYPE
|
|
SYNTAX IPXNET
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX Network Number associated with this table entry."
|
|
::= { a3ipxAttachedNetEntry 1 }
|
|
|
|
a3ipxAttachedNetPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port to which the IPX Network Number is assigned."
|
|
::= { a3ipxAttachedNetEntry 2 }
|
|
|
|
a3ipxAttachedNetFormat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet (1),
|
|
ieee (2),
|
|
llc (3),
|
|
snap (4),
|
|
ppp (5),
|
|
x25 (6),
|
|
fr (7),
|
|
smds (8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The format of the header used on packets sent to the
|
|
IPX Network Number associated with this table entry.
|
|
|
|
This object can be set to 1, 2, 3, or 4 when adding
|
|
an entry for a LAN interface. For WAN interfaces,
|
|
this object must be set to 5, 6, 7, or 8."
|
|
::= { a3ipxAttachedNetEntry 3 }
|
|
|
|
a3ipxAttachedNetType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primary(1),
|
|
secondary(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When more than one IPX Network Number is assigned to a
|
|
port, one must be labeled the primary number and the
|
|
rest secondary."
|
|
::= { a3ipxAttachedNetEntry 4 }
|
|
|
|
a3ipxAttachedNetOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (1),
|
|
down (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This identifies the current operational
|
|
state of an attached IPX network."
|
|
::= { a3ipxAttachedNetEntry 5 }
|
|
|
|
a3ipxAttachedNetStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to add and delete entries
|
|
in this table. See the notes describing
|
|
RowStatus at the beginning of this MIB."
|
|
::= { a3ipxAttachedNetEntry 6 }
|
|
|
|
|
|
--
|
|
-- This table contains a list of IPX routes
|
|
--
|
|
a3ipxRouteTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ipxRouteEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of IPX routes"
|
|
::= { a3ComIPX 5 }
|
|
|
|
a3ipxRouteEntry OBJECT-TYPE
|
|
SYNTAX A3ipxRouteEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry specifies an IPX route. The destination
|
|
of the route is specified by a3ipxRouteDestNet. The
|
|
next hop of the route is specified by a3ipxRouteAttachedNet
|
|
and a3ipxRouteDLAddress. Note, IPX routing must be
|
|
enabled before routes are exposed via this table."
|
|
INDEX { a3ipxRouteDestNet, a3ipxRouteType }
|
|
::= { a3ipxRouteTable 1 }
|
|
|
|
A3ipxRouteEntry ::= SEQUENCE {
|
|
a3ipxRouteDestNet IPXNET,
|
|
a3ipxRouteAttachedNet IPXNET,
|
|
a3ipxRouteDLType INTEGER,
|
|
a3ipxRouteDLAddress PhysAddress,
|
|
a3ipxRouteHops INTEGER,
|
|
a3ipxRouteType INTEGER,
|
|
a3ipxRouteProto INTEGER,
|
|
a3ipxRouteDelay INTEGER,
|
|
a3ipxRouteStatus RowStatus
|
|
}
|
|
|
|
a3ipxRouteDestNet OBJECT-TYPE
|
|
SYNTAX IPXNET
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX network number of the destination network.
|
|
The value 0xfffffffe is used to represent the
|
|
default route."
|
|
::= { a3ipxRouteEntry 1 }
|
|
|
|
a3ipxRouteAttachedNet OBJECT-TYPE
|
|
SYNTAX IPXNET
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The network number of the directly connected network
|
|
through which the router can reach the destination
|
|
network."
|
|
::= { a3ipxRouteEntry 2 }
|
|
|
|
a3ipxRouteDLType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet (1),
|
|
x25 (2),
|
|
frameRelay (3),
|
|
smds (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of network to which the closest router is
|
|
attached. This value is determined by the value of
|
|
a3ipxRouteAttachedNet."
|
|
::= { a3ipxRouteEntry 3 }
|
|
|
|
a3ipxRouteDLAddress OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Data Link address of the next hop router through which
|
|
the IPX network can be reached. The type of address is
|
|
determined by the value of a3ipxRouteDLType."
|
|
::= { a3ipxRouteEntry 4 }
|
|
|
|
a3ipxRouteHops OBJECT-TYPE
|
|
SYNTAX INTEGER (1..15)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of gateways that a packet has to pass through
|
|
before reaching the destination network. The maximum
|
|
number of hops is 15."
|
|
::= { a3ipxRouteEntry 5 }
|
|
|
|
a3ipxRouteType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primary (1),
|
|
secondary (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX Router allows up to two routes (ie, two separate
|
|
next hop routers) to a specific destination network,
|
|
only one of which will be the primary route. The
|
|
determination of which is primary and which is secondary
|
|
is based on the speed of the physical port used to
|
|
reach the next hop routers. If these are equal, the
|
|
number of hops is used to make this determination.
|
|
|
|
NOTE: NETBuilders running sw version 8.0 and greater
|
|
will only display primary routes, and when routes are
|
|
being added, only primary routes will be accepted."
|
|
::= { a3ipxRouteEntry 6 }
|
|
|
|
a3ipxRouteProto OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
static (2), -- static route
|
|
rip (3) -- dynamic route, learned via RIP
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object specifies how the entry was made."
|
|
::= { a3ipxRouteEntry 7 }
|
|
|
|
a3ipxRouteDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay associated with the route."
|
|
::= { a3ipxRouteEntry 8 }
|
|
|
|
a3ipxRouteStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to add and delete entries
|
|
in this table. See the notes describing
|
|
RowStatus at the beginning of this MIB. Note,
|
|
only statically learned routes may be removed
|
|
via this object. Dynamically learned routes
|
|
may be removed via the object a3ipxFlushRipSap."
|
|
::= { a3ipxRouteEntry 9 }
|
|
|
|
|
|
--
|
|
-- This next table has a list of reachable servers
|
|
--
|
|
a3ipxServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ipxServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of servers reachable via this router"
|
|
::= { a3ComIPX 6 }
|
|
|
|
a3ipxServerEntry OBJECT-TYPE
|
|
SYNTAX A3ipxServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry specifies the reachability of a server.
|
|
The server name is specified by a3ipxServerName. The
|
|
service is fully specified by a3ipxServerName, and
|
|
a3ipxServerType."
|
|
INDEX { a3ipxServerName, a3ipxServerType}
|
|
|
|
::= { a3ipxServerTable 1 }
|
|
|
|
A3ipxServerEntry ::= SEQUENCE {
|
|
a3ipxServerName DisplayString (SIZE (0..47)),
|
|
a3ipxServerType OCTET STRING(SIZE(2)),
|
|
a3ipxServerNet IPXNET,
|
|
a3ipxServerDLAddress MacAddress,
|
|
a3ipxServerSocket OCTET STRING (SIZE(2)),
|
|
a3ipxServerProto INTEGER,
|
|
a3ipxServerStatus RowStatus
|
|
}
|
|
|
|
a3ipxServerName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..47))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the server."
|
|
::= { a3ipxServerEntry 1 }
|
|
|
|
a3ipxServerType OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of service available on the server."
|
|
::= { a3ipxServerEntry 2 }
|
|
|
|
a3ipxServerNet OBJECT-TYPE
|
|
SYNTAX IPXNET
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX network number on which the server resides."
|
|
::= { a3ipxServerEntry 3 }
|
|
|
|
a3ipxServerDLAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Mac address of the server."
|
|
::= { a3ipxServerEntry 4 }
|
|
|
|
a3ipxServerSocket OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The socket number of the service."
|
|
::= { a3ipxServerEntry 5 }
|
|
|
|
a3ipxServerProto OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
static (2),
|
|
sap (3) -- dynamic, learned via sap
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object identifies how the entry was
|
|
made. If the entry was learned via the
|
|
Service Advertisement Protocol, this object will
|
|
have the value sap(3). If the entry was entered
|
|
statically, this object will have the value static(2)."
|
|
::= { a3ipxServerEntry 6 }
|
|
|
|
a3ipxServerStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table currently does not allow entries to
|
|
be added. This object is used to delete entries
|
|
from this table. See the notes describing
|
|
RowStatus at the beginning of this MIB. Note,
|
|
only statically learned service entries may
|
|
be removed via this object. To remove the
|
|
dynamically learned entries, use the object
|
|
a3ipxFlushRipSap."
|
|
::= { a3ipxServerEntry 7 }
|
|
|
|
|
|
--
|
|
-- This next table lists X25 configuration parameters
|
|
-- used for sending IPX packets across an X25 network
|
|
--
|
|
a3ipxX25configTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ipxX25configEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of IPX X25 configuration entries."
|
|
::= { a3ComIPX 7 }
|
|
|
|
a3ipxX25configEntry OBJECT-TYPE
|
|
SYNTAX A3ipxX25configEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry specifies a list of X25 configuration parameters
|
|
applying to an IPX port."
|
|
INDEX { a3ipxX25configPort }
|
|
::= { a3ipxX25configTable 1 }
|
|
|
|
A3ipxX25configEntry ::= SEQUENCE {
|
|
a3ipxX25configPort INTEGER,
|
|
a3ipxX25configPID INTEGER (1..'ff'h),
|
|
a3ipxX25configQueueSize INTEGER (1..128),
|
|
a3ipxX25configVClimit INTEGER (1..63),
|
|
a3ipxX25configVCtimer INTEGER (1..512),
|
|
a3ipxX25configProfId INTEGER (0..128)
|
|
}
|
|
|
|
a3ipxX25configPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port number to which this table entry applies."
|
|
::= { a3ipxX25configEntry 1 }
|
|
|
|
a3ipxX25configPID OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'ff'h)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The protocol ID that is included in all outgoing IPX
|
|
packets sent over the X25 port associated with this
|
|
table entry."
|
|
DEFVAL { 'ee'h }
|
|
::= { a3ipxX25configEntry 2 }
|
|
|
|
a3ipxX25configQueueSize OBJECT-TYPE
|
|
SYNTAX INTEGER (1..128)
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The maximum number of packets that can be queued
|
|
for a specific DTE address when the virtual circuit
|
|
or the X25 port is congested.
|
|
|
|
NOTE: this object is no longer supported by NETBuilders
|
|
running sw version 8.0 and greater. The corresponding
|
|
functionality has been replaced by the X25 Profile
|
|
feature. SNMP control over this feature will be
|
|
added at a later date."
|
|
DEFVAL { 2 }
|
|
::= { a3ipxX25configEntry 3 }
|
|
|
|
a3ipxX25configVClimit OBJECT-TYPE
|
|
SYNTAX INTEGER (1..63)
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The maximum number of virtual circuits that can
|
|
be established concurrently for IPX routing.
|
|
|
|
NOTE: this object is no longer supported by NETBuilders
|
|
running sw version 8.0 and greater. The corresponding
|
|
functionality has been replaced by the X25 Profile
|
|
feature. SNMP control over this feature will be
|
|
added at a later date."
|
|
DEFVAL { 2 }
|
|
::= { a3ipxX25configEntry 4 }
|
|
|
|
a3ipxX25configVCtimer OBJECT-TYPE
|
|
SYNTAX INTEGER (1..512)
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The maximum amount of time, in minutes, that can elapse
|
|
when there is no activity on the X25 virtual circuit
|
|
before it is cleared. This applies to the first virtual
|
|
circuit established for a particular DTE address. IF
|
|
more than one virtual circuit is established for the same
|
|
DTE address, all are cleared (except for the first one
|
|
established) when the first virtual circuit is not
|
|
experiencing congestion.
|
|
|
|
NOTE: this object is no longer supported by NETBuilders
|
|
running sw version 8.0 and greater. The corresponding
|
|
functionality has been replaced by the X25 Profile
|
|
feature. SNMP control over this feature will be
|
|
added at a later date."
|
|
DEFVAL { 2 }
|
|
::= { a3ipxX25configEntry 5 }
|
|
|
|
a3ipxX25configProfId OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To specify an X.25 profile that will be used
|
|
when the virtual circuit is set-up to carry
|
|
the IPX traffic. default (0) indicates that
|
|
no x25 profile is specified."
|
|
DEFVAL { 0 }
|
|
::= { a3ipxX25configEntry 6 }
|
|
|
|
--
|
|
-- SMDS Group Address Table
|
|
--
|
|
|
|
a3ipxSmdsGroupAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ipxSmdsGroupAddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of SMDS Group Addresses assigned to IPX Ports."
|
|
::= { a3ComIPX 8 }
|
|
|
|
a3ipxSmdsGroupAddressEntry OBJECT-TYPE
|
|
SYNTAX A3ipxSmdsGroupAddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry specifies the SMDS Group Address assigned
|
|
to an IPX port."
|
|
INDEX { a3ipxSmdsGaIpxPort }
|
|
::= { a3ipxSmdsGroupAddressTable 1 }
|
|
|
|
A3ipxSmdsGroupAddressEntry ::= SEQUENCE {
|
|
a3ipxSmdsGaIpxPort INTEGER,
|
|
a3ipxSmdsGaAddress SMDSAddress
|
|
}
|
|
|
|
a3ipxSmdsGaIpxPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This identifies an IPX port to which the
|
|
SMDS Group Address identified by the corresponding
|
|
instance of a3ipxSmdsGaAddress is associated."
|
|
::= { a3ipxSmdsGroupAddressEntry 1 }
|
|
|
|
a3ipxSmdsGaAddress OBJECT-TYPE
|
|
SYNTAX SMDSAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This identifies an SMDS Group address that
|
|
is used as the IPX multicast address on the
|
|
specified SMDS port. If this object has a value
|
|
of all zeros, then no SMDS Group address is
|
|
defined for this port."
|
|
::= { a3ipxSmdsGroupAddressEntry 2 }
|
|
|
|
--
|
|
-- IPX Preferred Server Table.
|
|
--
|
|
-- This table lists those IPX servers that are offered in
|
|
-- response to a "Get Nearest Server" request.
|
|
--
|
|
|
|
a3ipxPreferredSvrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ipxPreferredSvrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of those IPX servers that are included
|
|
in responses to 'Get Nearest Server' requests.
|
|
Separate lists are kept for each port. When
|
|
a request is receive over a particular port, this
|
|
system will respond with the preferred server
|
|
assigned to that port. If more than one preferred
|
|
server has been assigned to a particular port,
|
|
each server will be offered in a round robin
|
|
fashion. That is, if serverA, serverB, and
|
|
serverC have been assigned to port 1, serverA will
|
|
be offered in response to the first request,
|
|
serverB in response to the second request, and
|
|
so on."
|
|
::= { a3ComIPX 9 }
|
|
|
|
a3ipxPreferredSvrEntry OBJECT-TYPE
|
|
SYNTAX A3ipxPreferredSvrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry specifies an IPX server that will
|
|
be offered when a 'Get Nearest Server' request
|
|
in received over a particular port."
|
|
INDEX { a3ipxPrefSvrPort, a3ipxPrefSvrName }
|
|
::= { a3ipxPreferredSvrTable 1 }
|
|
|
|
A3ipxPreferredSvrEntry ::= SEQUENCE {
|
|
a3ipxPrefSvrPort INTEGER,
|
|
a3ipxPrefSvrName DisplayString (SIZE(0..47)),
|
|
a3ipxPrefSvrStatus RowStatus
|
|
}
|
|
|
|
a3ipxPrefSvrPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This identifies an IPX port to which the
|
|
IPX server identified by the corresponding
|
|
instance of a3ipxPrefSvrName is associated."
|
|
::= { a3ipxPreferredSvrEntry 1 }
|
|
|
|
a3ipxPrefSvrName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..47))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This identifies an IPX server that is offered
|
|
in response to 'Get Nearest Server' requests
|
|
received over the port identified by a3ipxPrefSvrPort.
|
|
If there exists more than one instance of this
|
|
object for a particular port, each will be
|
|
offered in a round robin fashion."
|
|
::= { a3ipxPreferredSvrEntry 2 }
|
|
|
|
a3ipxPrefSvrStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to add and remove entries
|
|
from this table. See the definition of RowStatus
|
|
at the beginning of this mib module for details."
|
|
::= { a3ipxPreferredSvrEntry 3 }
|
|
|
|
--
|
|
-- This next table lists other port-oriented params
|
|
--
|
|
a3ipxPortconfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ipxPortconfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of port-specific parmeters."
|
|
::= { a3ComIPX 10 }
|
|
|
|
a3ipxPortconfigEntry OBJECT-TYPE
|
|
SYNTAX A3ipxPortconfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry in this table applies the paramater over
|
|
a seperate port."
|
|
INDEX { a3ipxPortconfigPort }
|
|
::= { a3ipxPortconfigTable 1 }
|
|
|
|
A3ipxPortconfigEntry ::= SEQUENCE {
|
|
a3ipxPortconfigPort INTEGER,
|
|
a3ipxRipUpdateTime INTEGER (10..65535),
|
|
a3ipxSapUpdateTime INTEGER (10..65535),
|
|
a3ipxDefMetricHops INTEGER (0..15),
|
|
a3ipxDefMetricTicks INTEGER (1..65535)
|
|
}
|
|
|
|
a3ipxPortconfigPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port number to which this table entry applies."
|
|
::= { a3ipxPortconfigEntry 1 }
|
|
|
|
a3ipxRipUpdateTime OBJECT-TYPE
|
|
SYNTAX INTEGER (10..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies how often the router sends
|
|
RIP regular updates to exhange routing information.
|
|
This parameter is defined in units of seconds."
|
|
DEFVAL { 60 }
|
|
::= { a3ipxPortconfigEntry 2 }
|
|
|
|
a3ipxSapUpdateTime OBJECT-TYPE
|
|
SYNTAX INTEGER (10..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies how often the router sends
|
|
Sap regular updates to exhange and service information.
|
|
This parameter is defined in units of
|
|
seconds."
|
|
DEFVAL { 60 }
|
|
::= { a3ipxPortconfigEntry 3 }
|
|
|
|
a3ipxDefMetricHops OBJECT-TYPE
|
|
SYNTAX INTEGER (0..15)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies the hop value placed in NRIP
|
|
advertisements of the default route. If this object
|
|
has the value 0, the default route is not advertised."
|
|
DEFVAL { 0 }
|
|
::= { a3ipxPortconfigEntry 4 }
|
|
|
|
a3ipxDefMetricTicks OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies the number of ticks placed
|
|
in NLSP advertisements of the default route."
|
|
DEFVAL { 1 }
|
|
::= { a3ipxPortconfigEntry 5 }
|
|
|
|
|
|
--
|
|
-- This next table lists the port-oriented DOD Spoofing params
|
|
--
|
|
a3ipxSpoofCtlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ipxSpoofCtlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of spoof controls for all the ports. Each row,
|
|
represented by a3ipxSpoofCtlEntry, contains the various
|
|
spoof controls that are applicable to a port."
|
|
::= { a3ComIPX 11 }
|
|
|
|
a3ipxSpoofCtlEntry OBJECT-TYPE
|
|
SYNTAX A3ipxSpoofCtlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry represents the various spoof controls
|
|
applicable to a port."
|
|
INDEX { a3ipxSpoofCtlPort }
|
|
::= { a3ipxSpoofCtlTable 1 }
|
|
|
|
A3ipxSpoofCtlEntry ::= SEQUENCE {
|
|
a3ipxSpoofCtlPort INTEGER,
|
|
a3ipxSpoofCtlWatchdog INTEGER
|
|
}
|
|
|
|
a3ipxSpoofCtlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the port number, used as an index
|
|
to a row entry in the table."
|
|
::= { a3ipxSpoofCtlEntry 1 }
|
|
|
|
a3ipxSpoofCtlWatchdog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Used to enable(1) or disable(2) the Spoofing of
|
|
Watchdog packets."
|
|
DEFVAL { enabled }
|
|
::= { a3ipxSpoofCtlEntry 2 }
|
|
|
|
|
|
--
|
|
--
|
|
|
|
a3ipxRipHoldTimeFactor OBJECT-TYPE
|
|
SYNTAX INTEGER (1..24)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies a factor that RIP uses to generate
|
|
a hold time. A holdtime is generated by HoldTimeFactor *
|
|
UpdateTime. A entry in RIP will be aged out if further
|
|
update for it is not received within the hold time."
|
|
DEFVAL { 3 }
|
|
::= { a3ipxGeneral 8 }
|
|
|
|
a3ipxSapHoldTimeFactor OBJECT-TYPE
|
|
SYNTAX INTEGER (1..24)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies a factor that SAP uses to generate
|
|
a hold time. A holdtime is generated by HoldTimeFactor *
|
|
UpdateTime. A entry in SAP will be aged out if further
|
|
update for it is not received within the hold time."
|
|
DEFVAL { 3 }
|
|
::= { a3ipxGeneral 9 }
|
|
|
|
|
|
END
|
|
|