-- 3Com Switching Systems Remote Polling Management Information Base
|
|
-- Version 1.0.0
|
|
-- January 8, 1998
|
|
|
|
-- 3Com Corporation
|
|
-- 80 Central Street
|
|
-- Boxborough, MA 01719
|
|
-- (978) 264-1400
|
|
--
|
|
-- Change History:
|
|
-- Aug 14, 1998 - tmeiczin Fixed syntax to compile with SMICng
|
|
-- Jun 8, 1998 - gute edits from third review.
|
|
-- May 15, 1998 - gute edits from second review.
|
|
-- Jan 8, 1998 - gute edits from first review.
|
|
--
|
|
-- Revision 1.0.0 Initially created by Flavio Fernandes
|
|
-- Original structure inherited from blend of 3com0019.mib,
|
|
-- WFMIB.asn (Well Fleet) and lbhub-boom.mib
|
|
--
|
|
-- ======================================================================
|
|
--
|
|
-- Interpretation of the Interface Table for Remote Polling
|
|
--
|
|
-- OBJECT VALUE/USE
|
|
--
|
|
-- a3ComPollIndex A unique value, greater than zero for each
|
|
-- remote polling interface.
|
|
-- a3ComPollAddress Network address/hostname of the device to
|
|
-- monitor.
|
|
-- a3ComPollAddressType Method used to interpret device to
|
|
-- monitor's address, which implies on the
|
|
-- protocol to be used. (1)unknown, (2)ip,
|
|
-- (3)ipdotted, (4)ipname, (5)ipx,
|
|
-- (6)appletalk.
|
|
-- a3ComPollCount Number of ping packets to be sent
|
|
-- (0)continuous (1)default (2..9999)other
|
|
-- valid values.
|
|
-- a3ComPollAttempts Number of successful or unsuccessful
|
|
-- packets in sequence to trigger trap (0)trap
|
|
-- disabled/default (1..255) other valid
|
|
-- values.
|
|
-- a3ComPollRate Number of seconds between sending each ping
|
|
-- packet. (0)burst mode (3)default
|
|
-- (1,2,4..5400)other valid values.
|
|
-- a3ComPollResponseTimeOut Max wait time, in m-seconds, for a given
|
|
-- response packet (0)before sending/default
|
|
-- (1..65534)other valid values (65535)longest
|
|
-- timeout.
|
|
-- a3ComPollPacketSize Size, in bytes, of ping packet to be sent
|
|
-- out (0)use default packet size/default.
|
|
-- a3ComPollSourceAddress Local interface's address to receive ping
|
|
-- packets.
|
|
-- a3ComPollMinRoundTripTime Min round trip time value, in ms, of poll
|
|
-- cycle (0)unknown.
|
|
-- a3ComPollAvgRoundTripTime Avg round trip time value, in ms, of poll
|
|
-- cycle (0)unknown.
|
|
-- a3ComPollMaxRoundTripTime Max round trip time value, in ms, of poll
|
|
-- cycle (0)unknown.
|
|
-- a3ComPollFramesSent Number of packets sent.
|
|
-- a3ComPollFramesReceived Number of packets received.
|
|
-- a3ComPollInformation Object that contains any extra information,
|
|
-- interpreted depending on the protocol used.
|
|
-- a3ComPollOwner string with owner information.
|
|
-- a3ComPollReport (1)idle, (2)busy, (3)badArgument,
|
|
-- (4)noResource, (5)nameLookupFailed,
|
|
-- (6)hostAlive, (7)hostUnreachable,
|
|
-- (8)hostNotResponding.
|
|
-- a3ComPollAction (1)noop, (2)activate, (3)deactivate,
|
|
-- (4)reset stats and set default values and
|
|
-- (5)destroy.
|
|
--
|
|
-- a3ComPollNextFreeIndex Value of next available poll index.
|
|
-- a3ComPollTableInformation Object with summary information regarding
|
|
-- entire poll table.
|
|
-- a3ComPollTableActionAll (1)noop, (2)activate, (3)deactivate,
|
|
-- (4)reset stats and set default values and
|
|
-- (5)destroy.
|
|
--
|
|
-- a3ComPollResponseReceived TRAP triggered when disabled device begins
|
|
-- responding.
|
|
-- a3ComPollResponseNotReceived TRAP triggered when enabled device stops
|
|
-- responding.
|
|
-- ======================================================================
|
|
|
|
A3COM-SWITCHING-SYSTEMS-POLL-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
DisplayString FROM RFC1213-MIB
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215
|
|
enterprises FROM RFC1155-SMI
|
|
;
|
|
|
|
a3Com OBJECT IDENTIFIER ::= { enterprises 43 }
|
|
switchingSystemsMibs OBJECT IDENTIFIER ::= { a3Com 29 }
|
|
a3ComSwitchingSystemsMib OBJECT IDENTIFIER ::= { switchingSystemsMibs 4 }
|
|
|
|
-- Structure of MIB
|
|
--
|
|
-- The objects are arranged into the following groups:
|
|
--
|
|
-- 3Com switchingSystemsMibs a3ComSwitchingSystemsMib a3ComPoll
|
|
|
|
a3ComPoll OBJECT IDENTIFIER ::= { a3ComSwitchingSystemsMib 22 }
|
|
|
|
-- The 3COM Switching Remote Polling Interface Table
|
|
--
|
|
-- This table is implemented by the 3Com network devices that support
|
|
-- remote polling.
|
|
|
|
a3ComPollTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF A3ComPollEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table is used to provide remote device monitoring facilities.
|
|
|
|
The implementation allows a list of network devices to be set up
|
|
and polled regularly (or only once) by a variety of protocols.
|
|
The table can be configured to inform the management station(s)
|
|
of devices that are not responding to polls or that have started
|
|
to respond after a period of silence.
|
|
|
|
The minimum effort required to do a single poll is
|
|
1. In one packet, write the address and set a3ComPollAction to
|
|
activate(2).
|
|
2. In the next packet, read the a3ComPollReport.
|
|
|
|
The minimum effort required to monitor a device is
|
|
1. In one packet, write the address, set a3ComPollAttempts to 1,
|
|
set a3ComPollCount to 0 and set a3ComPollAction to activate(2).
|
|
2. Wait for traps to come in.
|
|
|
|
A row in this table is created by setting any read-write member,
|
|
indexed by the next available index (a3ComPollNextFreeIndex). This
|
|
method of creation makes the table very user friendly, although
|
|
a bit harder to detect racing conditions. The suggested method for
|
|
racing condition detection is by checking the a3ComPollAddress and
|
|
a3ComPollOwner objects while the a3ComPollReport object is set to
|
|
active. An example of the indexing of this table is a3ComPollRate.2"
|
|
::= { a3ComPoll 1 }
|
|
|
|
a3ComPollEntry OBJECT-TYPE
|
|
SYNTAX A3ComPollEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table used to define device monitoring. A row in this table is
|
|
created by setting any read-write member, indexed by the next
|
|
available index (a3ComPollNextFreeIndex). An entry in this table is
|
|
deleted by setting a3ComPollAction to destroy(5). An example of the
|
|
indexing of this table is a3ComPollRate.2 This method of creation
|
|
makes the table very user friendly, although a bit harder to detect
|
|
racing conditions. The suggested method for racing condition
|
|
detection is by checking the a3ComPollAddress and a3ComPollOwner
|
|
objects while the a3ComPollReport object is set to active."
|
|
INDEX { a3ComPollIndex }
|
|
::= { a3ComPollTable 1 }
|
|
|
|
A3ComPollEntry ::=
|
|
SEQUENCE {
|
|
a3ComPollIndex INTEGER,
|
|
a3ComPollAddress DisplayString,
|
|
a3ComPollAddressType INTEGER,
|
|
a3ComPollCount INTEGER,
|
|
a3ComPollAttempts INTEGER,
|
|
a3ComPollRate INTEGER,
|
|
a3ComPollResponseTimeOut INTEGER,
|
|
a3ComPollPacketSize INTEGER,
|
|
a3ComPollSourceAddress DisplayString,
|
|
a3ComPollMinRoundTripTime INTEGER,
|
|
a3ComPollAvgRoundTripTime INTEGER,
|
|
a3ComPollMaxRoundTripTime INTEGER,
|
|
a3ComPollFramesSent INTEGER,
|
|
a3ComPollFramesReceived INTEGER,
|
|
a3ComPollInformation DisplayString,
|
|
a3ComPollOwner DisplayString,
|
|
a3ComPollReport INTEGER,
|
|
a3ComPollAction INTEGER
|
|
}
|
|
|
|
a3ComPollIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unique identifier of a row in the Poll Table. The actual number
|
|
of rows that can be created on any particular device depends on
|
|
the memory and processing resources available at the time."
|
|
::= { a3ComPollEntry 1 }
|
|
|
|
a3ComPollAddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This DisplayString is the network address of the device to
|
|
monitor. Typically this is an IP, dotted IP format, IP's
|
|
hostname, IPX or AppleTalk. The following formats can be used:
|
|
IP cccc - ipAddress MIB
|
|
IP nnn.nnn.nnn.nnn - dotted format
|
|
IP hostname
|
|
IPX AABBCCDD:AABBCCDDEEFF - network : node
|
|
AppleTalk n[...].n[...] - dotted notation
|
|
|
|
The object a3ComPollAddressType is used to indicate how this
|
|
object will be interpreted.
|
|
|
|
This object may not be modified if the associated a3ComPollReport
|
|
is equal to busy(2). When this object is successfully set,
|
|
a3ComPollReport will be set to idle(1)."
|
|
::= { a3ComPollEntry 2 }
|
|
|
|
a3ComPollAddressType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
ip(2),
|
|
ipdotted(3),
|
|
ipname(4),
|
|
ipx(5),
|
|
appletalk(6)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This defines the method used to interpret the a3ComPollAddress,
|
|
which implies on the protocol to be used.
|
|
|
|
Writing an address to the a3ComPollAddress object causes a default
|
|
a3ComPollAddressType value to be setup. The default value is
|
|
derived from the format of the address - four octets means ip(2),
|
|
four sets of numeric values separated by dot means ipdotted(3), eight
|
|
and twelve octets separated by colon means ipx(5), and two sets of
|
|
numeric values separated by a dot means appletalk(6). If the address
|
|
type cannot be figured out, and this object is not currently set to
|
|
ipname(4), it will then be set to unknown(1). In other words, this
|
|
object will remain unchanged if its current value is ipname(4) and
|
|
a more specific type cannot be given to it. Thus, for the mot part,
|
|
when setting this object manually, that needs to be done after
|
|
setting a3ComPollAddress.
|
|
|
|
For ip hostname(4), this field must be set manually. Furthermore,
|
|
DNS client must be locally enabled to allow for conversion from name
|
|
to ip address.
|
|
|
|
If the requested protocol is not supported or is not compatible
|
|
with the a3ComPollAddress, an error is returned when an attempt is
|
|
made to set a3ComPollAction to activate(2), and a3ComPollReport will
|
|
be set to noResource(4).
|
|
|
|
This object may not be modified if the associated a3ComPollReport
|
|
is equal to busy(2). When this object is successfully set,
|
|
a3ComPollReport will be set to idle(1)."
|
|
DEFVAL { unknown }
|
|
::= { a3ComPollEntry 3 }
|
|
|
|
a3ComPollCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..9999)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This integer is the number of ping packets to be sent out until
|
|
completion of a polling command. If count is set to continuous(0),
|
|
the remote device will be kept monitored and the a3ComPollReport
|
|
will be normally set to busy(2) upon poll activation.
|
|
|
|
This object may not be modified if the associated a3ComPollReport
|
|
is equal to busy(2). When this object is successfully set,
|
|
a3ComPollReport will be set to idle(1)."
|
|
DEFVAL { 1 }
|
|
::= { a3ComPollEntry 4 }
|
|
|
|
a3ComPollAttempts OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of unsuccessful or successful requests necessary before
|
|
deciding that the device is definitely not responding or responding.
|
|
In order to use traps, a value greater than one must be used.
|
|
Conversely, a value of zero, which is the default, would imply that
|
|
traps are disabled.
|
|
|
|
This object may not be modified if the associated a3ComPollReport
|
|
object is equal to busy(2). When this object is successfully set,
|
|
a3ComPollReport will be set to idle(1)."
|
|
DEFVAL { 0 }
|
|
::= { a3ComPollEntry 5 }
|
|
|
|
a3ComPollRate OBJECT-TYPE
|
|
SYNTAX INTEGER (0..5400)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This defines how often, in seconds, a poll packet is sent to
|
|
the device being polled.
|
|
|
|
If burst mode(0) is chosen, then number of packets selected will
|
|
be sent out as fast as possible when the a3ComPollAction is set to
|
|
activate(2).
|
|
|
|
Common values the a3ComPollRate can be set to:
|
|
every 3 seconds (3) default every minute (60)
|
|
every 5 minutes (300) every 15 minutes (900)
|
|
every 30 minutes (1800) every hour (3600)
|
|
|
|
This object may not be modified if the associated a3ComPollReport
|
|
is equal to busy(2). When this object is successfully set,
|
|
a3ComPollReport will be set to idle(1)."
|
|
DEFVAL { 3 }
|
|
::= { a3ComPollEntry 6 }
|
|
|
|
a3ComPollResponseTimeOut OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum wait time, in msecs, for a response packet before deciding
|
|
that no response arrived. This object differs from a3ComPollRate
|
|
as the device have the sending and receiving queues independent,
|
|
making it possible to send ping requests at rates faster than
|
|
receiving.
|
|
|
|
The value of 0 (default) will be interpreted as a request for
|
|
time-out by the time a new packet is sent, and 65535 as a request for
|
|
maximum wait. Assuming that burst is used and this object is set to
|
|
one, most likely all packets sent will be interpreted as timed out.
|
|
|
|
This object may not be modified if the associated a3ComPollReport
|
|
is equal to busy(2). When this object is successfully set,
|
|
a3ComPollReport will be set to idle(1)."
|
|
DEFVAL { 0 }
|
|
::= { a3ComPollEntry 7 }
|
|
|
|
a3ComPollPacketSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..8191)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Size, in bytes, of ping packet to be sent out. If set to 0, the
|
|
default size for ping packet under the protocol chosen will be used.
|
|
If value given is to too large or too small, the biggest or smallest
|
|
possible packets will be used, respectively, and no errors will be
|
|
issued.
|
|
|
|
This object may not be modified if the associated a3ComPollReport
|
|
is equal to busy(2). When this object is successfully set,
|
|
a3ComPollReport will be set to idle(1)."
|
|
DEFVAL { 0 }
|
|
::= { a3ComPollEntry 8 }
|
|
|
|
a3ComPollSourceAddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This DisplayString is the network address of the local interface
|
|
to receive ping query. Typically this is an IP, IPX or AppleTalk.
|
|
The following formats can be used.
|
|
IP cccc - ipAddress MIB
|
|
IP nnn.nnn.nnn.nnn - dotted format
|
|
IPX AABBCCDD:AABBCCDDEEFF - network : node
|
|
AppleTalk n[...].n[...] - dotted notation
|
|
|
|
If a3ComPollSourceAddress is set to empty, which is the default
|
|
value, the sending device will pick the best interface to receive
|
|
the response for its queries.
|
|
|
|
The object a3ComPollAddressType is used to indicate how this
|
|
object will be interpreted, as well as a3ComPollAddress. An
|
|
exception exists when a3ComPollAddressType is set to ipname(4):
|
|
this object will be parsed as if a3ComPollAddressType was set to
|
|
ip(2) or as ipdotted(3), depending on the length of the object
|
|
value. Therefore, ip name is not supported for a3ComPollSourceAddress.
|
|
|
|
This object may not be modified if the associated a3ComPollReport
|
|
is equal to busy(2). When this object is successfully set,
|
|
a3ComPollReport will be set to idle(1)."
|
|
::= { a3ComPollEntry 9 }
|
|
|
|
a3ComPollMinRoundTripTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum amount of time taken, in msecs, for the round trip of a
|
|
ping packet."
|
|
::= { a3ComPollEntry 10 }
|
|
|
|
a3ComPollAvgRoundTripTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average amount of time taken, in msecs, for the round trip of a
|
|
ping packet."
|
|
::= { a3ComPollEntry 11 }
|
|
|
|
a3ComPollMaxRoundTripTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum amount of time taken, in msecs, for the round trip of a
|
|
ping packet."
|
|
::= { a3ComPollEntry 12 }
|
|
|
|
a3ComPollFramesSent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of ping packets sent to remote device so far."
|
|
::= { a3ComPollEntry 13 }
|
|
|
|
a3ComPollFramesReceived OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of ping packets responded by remote device so far.
|
|
If a3ComPollResponseTimeOut is a non-zero value, and the poll
|
|
response arrives after the specified timeout, this object will
|
|
not increment."
|
|
::= { a3ComPollEntry 14 }
|
|
|
|
a3ComPollInformation OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Depending on the protocol being used, this object contains extra
|
|
information obtained through the device poll. For IP, the value is
|
|
the number of packets that arrived out of sequence. If Apple Talk is
|
|
used, this value represents the number of hops. An empty string,
|
|
which is the default, stands for no extra information available.
|
|
|
|
This object will reset every time a change is observed on
|
|
a3ComPollAddressType."
|
|
::= { a3ComPollEntry 15 }
|
|
|
|
a3ComPollOwner OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RMON OwnerString conventions are used here to
|
|
help control the multi-manager situations."
|
|
::= { a3ComPollEntry 16 }
|
|
|
|
a3ComPollReport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
idle(1),
|
|
busy(2),
|
|
badArgument(3),
|
|
noResource(4),
|
|
nameLookupFailed(5),
|
|
hostAlive(6),
|
|
hostUnreachable(7),
|
|
hostNotResponding(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This integer contains the current status of the poll entry. When
|
|
the state changes from busy to any other, the entry is no longer
|
|
active. In situations where the a3ComPollCount field is set to
|
|
continuous(0), this object will normally be set to busy(2) upon
|
|
successful activation."
|
|
::= { a3ComPollEntry 17 }
|
|
|
|
a3ComPollAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noop(1),
|
|
activate(2),
|
|
deactivate(3),
|
|
reset(4),
|
|
destroy(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is the trigger for initiating, stopping, resetting and
|
|
destroying a poll entry. In order to read the current status of an
|
|
entry, a3ComPollReport is the object to be queried. If reset(4)
|
|
action is requested, the poll entry will unconditionally be moved
|
|
to the idle(1) state and all objects, except for the pollAddress
|
|
and pollAddressType will be set to initial values. Another object
|
|
that is not affected by reset(4) is the owner object. Activating
|
|
an entry that is in the busy(2) state has no effect."
|
|
DEFVAL { noop }
|
|
::= { a3ComPollEntry 18 }
|
|
|
|
a3ComPollNextFreeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index for the next available remote polling entry in the table."
|
|
::= { a3ComPoll 2 }
|
|
|
|
a3ComPollTableInformation OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object provides a summary on the entire poll table. Internal
|
|
thresholds, such as the maximum number of entries, as well the
|
|
number of entries that can be active simultaneously are commonly
|
|
provided here. Another information that can be given is the list of
|
|
protocols the agent can handle.
|
|
|
|
An empty string for a3ComPollTableInformation stands for no table
|
|
information available."
|
|
::= { a3ComPoll 3 }
|
|
|
|
a3ComPollTableActionAll OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noop(1),
|
|
activate(2),
|
|
deactivate(3),
|
|
reset(4),
|
|
destroy(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object works exactly as a3ComPollAction, except that it
|
|
affects every entry in the table, in one snmp transaction.
|
|
If a3ComPollTableActionAll is called with destroy(5), the table
|
|
is purged."
|
|
DEFVAL { noop }
|
|
::= { a3ComPoll 4 }
|
|
|
|
a3ComPollResponseReceived TRAP-TYPE
|
|
ENTERPRISE a3ComSwitchingSystemsMib
|
|
VARIABLES { a3ComPollAddress, a3ComPollAddressType,
|
|
a3ComPollAttempts, a3ComPollRate,
|
|
a3ComPollFramesSent, a3ComPollFramesReceived }
|
|
DESCRIPTION
|
|
"This trap is generated when the PollTable in the managed agent
|
|
receives replies to a poll after a sequence of unsuccessful polls.
|
|
The number of packets in such sequence is determined from the
|
|
a3ComPollAttempts object. The variables are:
|
|
|
|
a3ComPollAddress - the address of the device polled.
|
|
a3ComPollAddressType - the type of the address above.
|
|
a3ComPollAttempts - number of replies received in sequence before
|
|
this trap was triggered.
|
|
a3ComPollRate - rate at which device is being polled. 0 = burst.
|
|
a3ComPollFramesSent - total number of frames sent.
|
|
a3ComPollFramesReceived - total number of frames received.
|
|
|
|
This event is generated at most once per monitored device per
|
|
operation of a sequence of ping response when the event is first
|
|
observed."
|
|
::= 61
|
|
|
|
a3ComPollResponseNotReceived TRAP-TYPE
|
|
ENTERPRISE a3ComSwitchingSystemsMib
|
|
VARIABLES { a3ComPollAddress, a3ComPollAddressType,
|
|
a3ComPollAttempts, a3ComPollRate,
|
|
a3ComPollFramesSent, a3ComPollFramesReceived }
|
|
DESCRIPTION
|
|
"This trap is generated when the PollTable in the managed agent
|
|
receives no replies to a poll after a sequence of successful polls.
|
|
The number of packets in such sequence is determined from the
|
|
a3ComPollAttempts object. The variables are:
|
|
|
|
a3ComPollAddress - the address of the device polled.
|
|
a3ComPollAddressType - the type of the address above.
|
|
a3ComPollAttempts - number of replies missed in sequence before
|
|
this trap was triggered.
|
|
a3ComPollRate - rate at which device is being polled. 0 = burst.
|
|
a3ComPollFramesSent - total number of frames sent.
|
|
a3ComPollFramesReceived - total number of frames received.
|
|
|
|
This event is generated at most once per monitored device per
|
|
operation of a sequence of ping fails when the event is first
|
|
observed."
|
|
::= 62
|
|
|
|
END
|