Observium_CE/mibs/a3com/A3COM-HUAWEI-T1-MIB

351 lines
12 KiB
Plaintext

-- =============================================================
-- Copyright (c) 2004-2009 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
--
-- Description:
-- Reference: extension of RFC 1213 and RFC 2233
-- Version: V1.1
-- History:
-- V1.0 2004-12-01
-- Initial Version by lizhiyong and fangmin
-- V1.1 2009-06-08 modified by TONGWEI
-- Added h3ct1Table and h3ct1InterfaceTable
-- =============================================================
A3COM-HUAWEI-T1-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32,
Counter32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
ifIndex
FROM RFC1213-MIB
h3cCommon
FROM A3COM-HUAWEI-OID-MIB;
-- =============================================================
-- T1 Module
-- =============================================================
h3cT1 MODULE-IDENTITY
LAST-UPDATED "200906080000Z"
ORGANIZATION
"Hangzhou H3C Technologies Co., Ltd."
CONTACT-INFO
"Platform Team H3C Technologies Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip: 100085"
DESCRIPTION
"This MIB provides T1 interface information that are
excluded by RFC 1213 and RFC 2233"
REVISION "200906081741Z"
DESCRIPTION
"To fix bugs in the MIB file."
REVISION "200412011436Z"
DESCRIPTION
"Initial version of this MIB module."
::= { h3cCommon 29 }
t1InterfaceStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1InterfaceStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains interface packet statistics "
::= { h3cT1 1 }
t1InterfaceStatusEntry OBJECT-TYPE
SYNTAX T1InterfaceStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry contains interface packet statistics.
The index of this Entry is ifIndex defined in ifTable
of RFC1213-MIB"
INDEX { ifIndex }
::= { t1InterfaceStatusTable 1 }
T1InterfaceStatusEntry ::= SEQUENCE {
t1InterfaceInErrs Counter32,
t1InterfaceInRuntsErrs Counter32,
t1InterfaceInGiantsErrs Counter32,
t1InterfaceInCrcErrs Counter32,
t1InterfaceInAlignErrs Counter32,
t1InterfaceInOverRunsErrs Counter32,
t1InterfaceInDribblesErrs Counter32,
t1InterfaceInAbortedSeqErrs Counter32,
t1InterfaceInNoBufferErrs Counter32,
t1InterfaceInFramingErrs Counter32,
t1InterfaceOutputErrs Counter32,
t1InterfaceOutUnderRunErrs Counter32,
t1InterfaceOutCollisonsErrs Counter32,
t1InterfaceOutDeferedErrs Counter32
}
t1InterfaceInErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of error received on this interface"
::= { t1InterfaceStatusEntry 1 }
t1InterfaceInRuntsErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Runts Error(too short packet) received on this interface"
::= { t1InterfaceStatusEntry 2 }
t1InterfaceInGiantsErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Giants Error(too long packet) received on this interface"
::= { t1InterfaceStatusEntry 3 }
t1InterfaceInCrcErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of CRC Error received on this interface"
::= { t1InterfaceStatusEntry 4 }
t1InterfaceInAlignErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Align Error received on this interface"
::= { t1InterfaceStatusEntry 5 }
t1InterfaceInOverRunsErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Over Runs Error received on this interface"
::= { t1InterfaceStatusEntry 6 }
t1InterfaceInDribblesErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of dribble packets received"
::= { t1InterfaceStatusEntry 7 }
t1InterfaceInAbortedSeqErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of AbortedSeq Error received on this interface"
::= { t1InterfaceStatusEntry 8 }
t1InterfaceInNoBufferErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Error (no buffer available)"
::= { t1InterfaceStatusEntry 9 }
t1InterfaceInFramingErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of framing Errors"
::= { t1InterfaceStatusEntry 10 }
t1InterfaceOutputErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of total Error transmited on this interface"
::= { t1InterfaceStatusEntry 11 }
t1InterfaceOutUnderRunErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of UnderRun Error transmited on this interface"
::= { t1InterfaceStatusEntry 12 }
t1InterfaceOutCollisonsErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Collisions Error transmited on this interface"
::= { t1InterfaceStatusEntry 13 }
t1InterfaceOutDeferedErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Deferred Error transmited on this interface"
::= { t1InterfaceStatusEntry 14 }
h3ct1Table OBJECT-TYPE
SYNTAX SEQUENCE OF H3cT1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of T1 interface entries."
::= { h3cT1 2 }
h3ct1Entry OBJECT-TYPE
SYNTAX H3cT1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry contains T1 interface management information."
INDEX { ifIndex }
::= { h3ct1Table 1 }
H3cT1TimeSlot ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Each octet within this value specifies a set of time
slots, with the first octet specifying time slot 1 through
8, the second octet specifying time slots 9 through 16, etc.
Within each octet, the most significant bit represents
the highest numbered time slot, and the least significant bit
represents the lowest numbered time slot. Thus, each time slot
of the T1 is represented by a single bit within the
value of this object. If that bit has a value of '1'
then that time slot is included in the set of time slots;
the time slot is not included if its bit has a value of '0'."
SYNTAX OCTET STRING(SIZE (3))
H3cT1Entry ::= SEQUENCE {
h3ct1Type BITS,
h3ct1Clock INTEGER,
h3ct1FrameFormat INTEGER,
h3ct1LineCode INTEGER,
h3ct1PriSetTimeSlot H3cT1TimeSlot,
h3ct1DChannelIndex Integer32,
h3ct1SubScribLineChannelIndex Integer32
}
h3ct1Type OBJECT-TYPE
SYNTAX BITS {
voice(0)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the type of the T1 interface."
::= { h3ct1Entry 1 }
h3ct1Clock OBJECT-TYPE
SYNTAX INTEGER {
slave(1),
master(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the clock type used on the T1 interface."
DEFVAL { slave }
::= { h3ct1Entry 2 }
h3ct1FrameFormat OBJECT-TYPE
SYNTAX INTEGER {
sf(1),
esf(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the frame format used on the T1 interface."
DEFVAL { esf }
::= { h3ct1Entry 3 }
h3ct1LineCode OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
b8zs(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the line code type used on the T1 interface."
DEFVAL { b8zs }
::= { h3ct1Entry 4 }
h3ct1PriSetTimeSlot OBJECT-TYPE
SYNTAX H3cT1TimeSlot
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a bit-map of PRI time slots used on the T1 interface.
It needs to administratively shut down the D channel of
the T1 interface before cancelling PRI time slots."
::= { h3ct1Entry 5 }
h3ct1DChannelIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the ifIndex of the D channel of the T1 interface."
::= { h3ct1Entry 6 }
h3ct1SubScribLineChannelIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the ifIndex of the subscriber-line channel of the T1 interface."
::= { h3ct1Entry 7 }
h3ct1InterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cT1InterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of channels of T1 interface entries.
Including D channels and subscriber-line channels."
::= { h3cT1 3 }
h3ct1InterfaceEntry OBJECT-TYPE
SYNTAX H3cT1InterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry contains channels of T1 interface management information.
Including D channels and subscriber-line channels."
INDEX { ifIndex }
::= { h3ct1InterfaceTable 1 }
H3cT1InterfaceEntry ::= SEQUENCE {
h3ct1ControllerIndex Integer32
}
h3ct1ControllerIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which T1 interface is this channel belonged to."
::= { h3ct1InterfaceEntry 1 }
END