Observium_CE/mibs/a3com/A3COM-HUAWEI-SNA-DLSW-MIB

1757 lines
56 KiB
Plaintext

-- =============================================================
-- Copyright IETF . All rights reserved.
--
-- Description: This file describes the huawei mib implementation of dlsw
-- Reference: extracted from RFC2024 and modified.
-- Version: V1.3
-- History:
-- for V1.0
-- dlswNodeUpTime is obsolete
-- dlswRemotePeerNumOfTcpSessions is obsolete
-- dlswRemotePeerSetStateToConfig is obsolete
-- dlswCircuitS2Location is obsolete
-- dlswCircuitPriority is obsolete
-- dlswCircuitFCLargestRecvGranted is obsolete
-- dlswCircuitFCLargestSendGranted is obsolete
-- dlswSdlcPortNrziEncoding is obsolete
-- dlswSdlcPortIdleMarkEnable is obsolete
-- the value of dlswRemotePeerKeepAlive is changed from (1-1200) to (1-60000)
-- V1.1 9th Dec 2003
-- a3comoemrouter.mib added
-- V1.2 2004-11-03 updated by lizhiyong
-- Modify IMPORTS clause, imports some types.
-- Delete some comments
-- Delete huawei from IMPORTS clause
-- Rewrite trap object with SMIv2 syntax. Including
-- dlswTrapTConnPartnerReject,
-- dlswTrapTConnChangeState,
-- dlswTrapCircuitChangeState
-- Adding dlswTrapsV2 object for compatible with SNMPv1 trap.
-- Change some INTEGER syntax to Integer32 syntax
-- V1.3 shejunquan 2006-06-28
-- Modify range of 4 nodes. Including
-- dlswNodeConnTimeout,
-- dlswNodeLocalPendTimeout,
-- dlswNodeRemotePendTimeout,
-- dlswNodeSnaCacheTimeout
-- Modify default value of dlswNodeLocalPendTimeout.
-- =============================================================
A3COM-HUAWEI-SNA-DLSW-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString,
TEXTUAL-CONVENTION
FROM SNMPv2-TC
Counter32,
Gauge32,
IpAddress,
TimeTicks,
OBJECT-TYPE,
MODULE-IDENTITY,
NOTIFICATION-TYPE,
Integer32
FROM SNMPv2-SMI
ifIndex
FROM RFC1213-MIB
hwproducts
FROM A3COM-HUAWEI-OID-MIB;
dlsw MODULE-IDENTITY
LAST-UPDATED "200410301551Z"
ORGANIZATION "Huawei-3com Technologies co.,Ltd."
CONTACT-INFO
"Platform Team Beijing Institute Huawei-3com Tech, Inc.
Http://www.huawei-3com.com
E-mail:support@huawei-3com.com "
DESCRIPTION
"private mib for dlsw"
::= { hwproducts 34 }
--======================================
-- Textual convention definitions
--======================================
MacAddressNC ::= TEXTUAL-CONVENTION
DISPLAY-HINT "1x:"
STATUS current
DESCRIPTION
"Represents an 802 MAC address represented in
non-canonical format. That is, the most significant
bit will be transmitted first. If this information
is not available, the value is a zero length string."
SYNTAX OCTET STRING (SIZE (0 | 6))
EndStationLocation ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Representing the location of an end station related
to the managed DLSw node."
SYNTAX INTEGER {
other (1),
internal (2), -- local virtual MAC address
remote (3), -- via DLSw partner
local (4) -- locally attached
}
DlcType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Representing the type of DLC of an end station, if
applicable."
SYNTAX INTEGER {
other (1), -- not assigned yet
na (2), -- not applicable
llc (3), -- 802.2 Logical Link Control
sdlc (4), -- SDLC
qllc (5) -- QLLC
}
LFSize ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The largest size of the INFO field (including DLC header,
not including any MAC-level or framing octets).
64 valid values as defined by the IEEE 802.1D
Addendum are acceptable."
SYNTAX INTEGER {
lfs516(516), lfs1470(1470), lfs1500(1500),
lfs2052(2052), lfs4472(4472), lfs8144(8144),
lfs11407(11407), lfs11454(11454), lfs17800(17800), unknown(65535)
}
CreateLineFlag ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The 'DeleteLine' value means deleting a conceptual row object.
The 'createLine' value means adding a conceptual row object."
SYNTAX INTEGER
{ createLine(1),
deleteLine(2)
}
EntryStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The status of a table entry."
SYNTAX INTEGER
{ valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
--==================================================================
-- DLSw MIB Definition
--==================================================================
-- The DLSw MIB module contains an object part .
-- Object part is organized in the following groups:
-- (1) dlswNode information about this DLSw
-- (2) dlswTConn about adjacent DLSw partners
-- (3) dlswInterface about which interfaces DLSw is active on
-- (4) dlswDirectory about any directory of local/remote resources
-- (5) dlswCircuit about established circuits
-- (6) dlswSdlc about SDLC data link switched devices
-- (7) dlswLlc2 about LLC2 data link switched devices
dlswNode OBJECT IDENTIFIER ::= { dlsw 1 }
dlswTConn OBJECT IDENTIFIER ::= { dlsw 2 }
dlswBridgeGroup OBJECT IDENTIFIER ::= { dlsw 3 }
dlswLocDirectory OBJECT IDENTIFIER ::= { dlsw 4 }
dlswCircuit OBJECT IDENTIFIER ::= { dlsw 5 }
dlswSdlc OBJECT IDENTIFIER ::= { dlsw 6 } -- SDLC
dlswLlc2 OBJECT IDENTIFIER ::= { dlsw 7 } -- LLC2
--==================================================================
-- THE NODE GROUP
--==================================================================
--==================================================================
-- DLSw Node Identity
--==================================================================
dlswNodeVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value identifies the particular version of the DLSw
standard supported by this DLSw. The first octet is a
hexadecimal value representing the DLSw standard Version
number of this DLSw, and the second is a hexadecimal value
representing the DLSw standard Release number. This
information is reported in DLSw Capabilities Exchange."
REFERENCE
"DLSW: Switch-to-Switch Protocol RFC 1795"
::= { dlswNode 1 }
dlswNodeVendorID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value identifies the manufacturer's IEEE-assigned
organizationally Unique Identifier (OUI) of this DLSw.
This information is reported in DLSw Capabilities
Exchange."
REFERENCE
"DLSW: Switch-to-Switch Protocol RFC 1795"
::= { dlswNode 2 }
dlswNodeVersionString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string gives product-specific information about
this DLSw (e.g., product name, code release and fix level).
This flows in Capabilities Exchange messages."
REFERENCE
"DLSW: Switch-to-Switch Protocol RFC 1795"
::= { dlswNode 3 }
--==================================================================
-- DLSw Code Capability
--==================================================================
dlswNodeStdPacingSupport OBJECT-TYPE
SYNTAX INTEGER {
none (1), -- does not support DLSw
-- Standard pacing scheme
adaptiveRcvWindow (2), -- the receive window size
-- varies
fixedRcvWindow (3), -- the receive window size
-- remains constant
unknown (65535) -- unknown value
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Circuit pacing, as defined in the DLSw Standard, allows each
of the two DLSw nodes on a circuit to control the amount
of data the other is permitted to send to them. This object
reflects the level of support the DLSw node has for this
protocol. (1) means the node has no support for the standard
circuit pacing flows; it may use RFC 1434+ methods only, or
a proprietary flow control scheme. (2) means the node supports
the standard scheme and can vary the window sizes it grants as
a data receiver. (3) means the node supports the standard
scheme but never varies its receive window size."
::= { dlswNode 4 }
--==================================================================
-- DLSw Node Operational Objects
--==================================================================
dlswNodeStatus OBJECT-TYPE
SYNTAX INTEGER {
active (1),
inactive (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the DLSw part of the system. "
::= { dlswNode 5 }
dlswNodeUpTime OBJECT-TYPE
SYNTAX Integer32
UNITS "second"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The amount of time (in hundredths of a second) since
the DLSw portion of the system was last re-initialized.
That is, if dlswState is in the active state,
the time the dlswState entered the active state.
It will remain zero if dlswState is in the
inactive state."
::= { dlswNode 6 }
dlswNodeVirtualSegmentLFSize OBJECT-TYPE
SYNTAX LFSize
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The largest frame size (including DLC header and info field
but not any MAC-level or framing octets) this DLSw can forward
on any path through itself. This object can represent any box-
level frame size forwarding restriction (e.g., from the use
of fixed-size buffers). Some DLSw implementations will have
no such restriction.
This value will affect the LF size of circuits during circuit
creation. The LF size of an existing circuit can be found in
the RIF (Routing Information Field)."
DEFVAL { lfs1500 }
::= { dlswNode 7 }
--==================================================================
-- DLSw Local Peer
--==================================================================
dlswNodeLocalAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Local peer ip address. "
::= { dlswNode 8 }
dlswNodePriority OBJECT-TYPE
SYNTAX Integer32 (1..5|65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The priority value of local peer. 65535 expresses the value is unknown"
DEFVAL { 5 }
::= { dlswNode 9 }
dlswNodeInitWindow OBJECT-TYPE
SYNTAX Integer32 (1..2000|65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The vlaue of init-window. 65535 expresses the value is unknown"
DEFVAL { 40 }
::= { dlswNode 10 }
dlswNodeKeepAlive OBJECT-TYPE
SYNTAX Integer32 (1..2000|65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The vlaue of keepalive interval. 65535 expresses the value is unknown"
DEFVAL { 30 }
::= { dlswNode 11 }
dlswNodeMaxWindow OBJECT-TYPE
SYNTAX Integer32 (1..2000|65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of max-window. 65535 expresses the value is unknown"
DEFVAL { 255 }
::= { dlswNode 12 }
dlswNodePermitDynamic OBJECT-TYPE
SYNTAX INTEGER {
permitDynamic(1),
forbidDynamic(2),
unknown(65535)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To accept connections from non-configured remote peers when
permit-dynamic is setted. "
DEFVAL { forbidDynamic }
::= { dlswNode 13 }
--==================================================================
-- DLSw node Timer
--==================================================================
dlswNodeConnTimeout OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define connected state timer(The unit is a thousandth of a
second). "
DEFVAL { 300 }
::= { dlswNode 14 }
dlswNodeLocalPendTimeout OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define connected state timer(The unit is a thousandth of a
second)."
DEFVAL { 30 }
::= { dlswNode 15 }
dlswNodeRemotePendTimeout OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define connected state timer(The unit is a thousandth of a
second). "
DEFVAL { 30 }
::= { dlswNode 16 }
dlswNodeSnaCacheTimeout OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define connected state timer(The unit is a thousandth of a
second). "
DEFVAL { 120 }
::= { dlswNode 17 }
--==================================================================
-- Transport Connection Table
--==================================================================
dlswRemotePeerTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlswRemotePeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of tcp transport connections. "
::= { dlswTConn 1 }
dlswRemotePeerEntry OBJECT-TYPE
SYNTAX DlswRemotePeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of remote peer information"
INDEX { dlswRemotePeerAddr }
::= { dlswRemotePeerTable 1 }
DlswRemotePeerEntry ::=
SEQUENCE {
dlswRemotePeerAddr
IpAddress,
dlswRemotePeerVersion
OCTET STRING,
dlswRemotePeerVendorID
OCTET STRING,
dlswRemotePeerPaceWindInit
Integer32,
dlswRemotePeerNumOfTcpSessions
Integer32,
dlswRemotePeerVersionString
DisplayString,
dlswRemotePeerIsConfig
INTEGER,
dlswRemotePeerSetStateToConfig
INTEGER,
dlswRemotePeerCost
Integer32,
dlswRemotePeerKeepAlive
Integer32,
dlswRemotePeerLf
LFSize,
dlswRemotePeerTcpQueneMax
Integer32,
dlswRemotePeerHaveBackup
INTEGER,
dlswRemotePeerIsBackup
INTEGER,
dlswRemotePeerBackupAddr
IpAddress,
dlswRemotePeerLinger
Integer32,
dlswRemotePeerLinkState
INTEGER,
dlswRemotePeerRecvPacks
Counter32,
dlswRemotePeerSendPacks
Counter32,
dlswRemotePeerDrops
Counter32,
dlswRemotePeerUptime
Counter32,
dlswRemotePeerEntryStatus
EntryStatus
}
dlswRemotePeerAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The remote peer address for this transport connection. "
::= { dlswRemotePeerEntry 1 }
dlswRemotePeerVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value identifies which version (first octet) and release
(second octet) of the DLSw standard is supported by this
partner DLSw. This information is obtained from a DLSw
capabilities exchange message received from the partner DLSw.
A string of zero length is returned before a Capabilities
Exchange message is received, or if one is never received.
A conceptual row with a dlswTConnOperState of `connected' but
a zero length partner version indicates that the partner is
a non-standard DLSw partner.
If an implementation chooses to keep dlswTConnOperEntrys in
the `disconnected' state, this value should remain unchanged."
::= { dlswRemotePeerEntry 2 }
dlswRemotePeerVendorID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value identifies the IEEE-assigned organizationally
Unique Identifier (OUI) of the maker of this partner
DLSw. This information is obtained from a DLSw
capabilities exchange message received from the partner DLSw.
A string of zero length is returned before a Capabilities
Exchange message is received, or if one is never received.
If an implementation chooses to keep dlswTConnOperEntrys in
the `disconnected' state, this value should remain unchanged."
::= { dlswRemotePeerEntry 3 }
dlswRemotePeerPaceWindInit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the partner initial receive pacing window. This
is our initial send pacing window for all new circuits on this
transport connection, as modified and granted by the first flow
control indication the partner sends on each circuit.
This information is obtained from a DLSw capabilities exchange
message received from the partner DLSw.
A value of zero is returned before a Capabilities
Exchange message is received, or if one is never received.
If an implementation chooses to keep dlswTConnOperEntrys in
the `disconnected' state, this value should remain unchanged."
::= { dlswRemotePeerEntry 4 }
dlswRemotePeerNumOfTcpSessions OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Number of TCP sessionss. "
::= { dlswRemotePeerEntry 5 }
dlswRemotePeerVersionString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value identifies the particular product version (e.g.,
product name, code level, fix level) of this partner DLSw.
The format of the actual version string is vendor-specific.
This information is obtained from a DLSw capabilities exchange
message received from the partner DLSw.
A string of zero length is returned before a Capabilities
Exchange message is received, if one is never received, or
if one is received but it does not contain a version string.
If an implementation chooses to keep dlswTConnOperEntrys in
the `disconnected' state, this value should remain unchanged."
::= { dlswRemotePeerEntry 6 }
dlswRemotePeerIsConfig OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current remote peer is configrured when the value is 'yes'."
::= { dlswRemotePeerEntry 7 }
dlswRemotePeerSetStateToConfig OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"When the value is set 'yes' from 'no', dlswRemotePeerIsConfig
will change from 'no' to 'yes'."
::= { dlswRemotePeerEntry 8 }
dlswRemotePeerCost OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The cost for remote peer. "
::= { dlswRemotePeerEntry 9 }
dlswRemotePeerKeepAlive OBJECT-TYPE
SYNTAX Integer32 (1..60000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The keepalive interval value. "
::= { dlswRemotePeerEntry 10 }
dlswRemotePeerLf OBJECT-TYPE
SYNTAX LFSize
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The the largest frame size. "
::= { dlswRemotePeerEntry 11 }
dlswRemotePeerTcpQueneMax OBJECT-TYPE
SYNTAX Integer32 (50..2000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The max tcp queue value. "
::= { dlswRemotePeerEntry 12 }
dlswRemotePeerHaveBackup OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"There is another remote peer whitch is configrued as the
backup of the current remote peer . "
::= { dlswRemotePeerEntry 13 }
dlswRemotePeerIsBackup OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current remote peer is configrued as the
backup of another configured remote peer . "
::= { dlswRemotePeerEntry 14 }
dlswRemotePeerBackupAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is the IP ADDRESS of an configured remote peer of whitch
the current remote peer is configrued as the backup "
::= { dlswRemotePeerEntry 15 }
dlswRemotePeerLinger OBJECT-TYPE
SYNTAX Integer32 (0..1440)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Buckup Peer linger"
DEFVAL { 5 }
::= { dlswRemotePeerEntry 16 }
dlswRemotePeerLinkState OBJECT-TYPE
SYNTAX INTEGER {
connecting (1),
initCapExchange (2),
connected (3),
quiescing (4),
disconnecting (5),
disconnected (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of this tcp transport connection. "
::= { dlswRemotePeerEntry 17 }
dlswRemotePeerRecvPacks OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Switch-to-Switch Protocol (SSP) messages
received on this tcp transport connection."
::= { dlswRemotePeerEntry 18 }
dlswRemotePeerSendPacks OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Switch-to-Switch Protocol (SSP) messages
sent on this tcp transport connection."
::= { dlswRemotePeerEntry 19 }
dlswRemotePeerDrops OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Switch-to-Switch Protocol (SSP) messages
dropped on this tcp transport connection."
::= { dlswRemotePeerEntry 20 }
dlswRemotePeerUptime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time (in seconds ) since this transport
connection last entered the 'connected' state."
::= { dlswRemotePeerEntry 21 }
dlswRemotePeerEntryStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used by the manager to create
or delete the row entry in the dlswRemotePeerTable
following the EntryStatus textual convention. "
::= { dlswRemotePeerEntry 22 }
-- ==================================================================
-- DLSW dlswBridgeGroup GROUP
--==================================================================
dlswBridgeTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlswBridgeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of bridge group whitch has been created."
::= { dlswBridgeGroup 1 }
dlswBridgeEntry OBJECT-TYPE
SYNTAX DlswBridgeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of bridge information"
INDEX { dlswBridgeNum }
::= { dlswBridgeTable 1 }
DlswBridgeEntry ::= SEQUENCE {
dlswBridgeNum Integer32,
dlswBridgeStatus CreateLineFlag
}
dlswBridgeNum OBJECT-TYPE
SYNTAX Integer32 (1..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" This value identifies the bridge number ."
::= { dlswBridgeEntry 1 }
dlswBridgeStatus OBJECT-TYPE
SYNTAX CreateLineFlag
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 'DeleteLine' value means deleting a conceptual row object.
The 'createLine' value means adding a conceptual row object."
::= { dlswBridgeEntry 2 }
--==================================================================
-- DLSW Bridge group number and interface
--==================================================================
dlswBridgeIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlswBridgeIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of interfaces on which DLSw is active."
::= { dlswBridgeGroup 2 }
dlswBridgeIfEntry OBJECT-TYPE
SYNTAX DlswBridgeIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of bridge interface information"
INDEX { ifIndex }
::= { dlswBridgeIfTable 1 }
DlswBridgeIfEntry ::= SEQUENCE {
dlswBridgeIfBriGru Integer32,
dlswBridgeIfName DisplayString,
dlswBridgeIfStatus EntryStatus
}
dlswBridgeIfBriGru OBJECT-TYPE
SYNTAX Integer32 (1..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This value identifies the bridge number attached
to the interface."
::= { dlswBridgeIfEntry 1 }
dlswBridgeIfName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The name of the interface. "
::= { dlswBridgeIfEntry 2 }
dlswBridgeIfStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This value whitch is equal to 'invalid' identifies to
delete a conceptual row "
::= { dlswBridgeIfEntry 3 }
-- ==================================================================
-- DIRECTORY
--
-- ==================================================================
--==================================================================
-- Directory Cache
-- ==================================================================
dlswLocMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlswLocMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains locations of MAC addresses.
They are local and reachable"
::= { dlswLocDirectory 1 }
dlswLocMacEntry OBJECT-TYPE
SYNTAX DlswLocMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information of table"
INDEX { dlswLocMacHashIndex , dlswLocMacHashIndexSeqNum}
::= { dlswLocMacTable 1 }
DlswLocMacEntry ::=
SEQUENCE {
dlswLocMacHashIndex
Integer32,
dlswLocMacHashIndexSeqNum
Integer32,
dlswLocMacMac
MacAddressNC,
dlswLocMacLocalInterfaceName
DisplayString
}
dlswLocMacHashIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The hash value."
::= { dlswLocMacEntry 1 }
dlswLocMacHashIndexSeqNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The sequence num with smae hash value."
::= { dlswLocMacEntry 2 }
dlswLocMacMac OBJECT-TYPE
SYNTAX MacAddressNC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The MAC address. "
::= { dlswLocMacEntry 3 }
dlswLocMacLocalInterfaceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The value is the interface name when
dlswLocMacLocationType is 'local'. "
::= { dlswLocMacEntry 4 }
-- ==================================================================
-- CIRCUIT
-- A circuit is the end-to-end association between two DLSw entities
-- or two DLSw nodes.
-- ==================================================================
-- ==================================================================
-- Circuit Table
-- This table is the DLSw entity's view of circuits.
-- ==================================================================
dlswCircuitTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlswCircuitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is the circuit representation in the DLSw
entity. Virtual data links are used to represent any internal
end stations. There is a conceptual row associated with
each data link. Thus, for circuits without an intervening
transport connection, there are two conceptual rows
for each circuit.
The table consists of the circuits being established,
established, and as an implementation option, circuits that
have been disconnected. For circuits carried over
transport connections, an entry is created after
the CUR_cs was sent or received. For circuits between
two locally attached devices, or internal virtual MAC
addresses, an entry is created when the equivalent of
CUR_cs sent/received status is reached.
End station 1 (S1) and End station 2 (S2) are used to
represent the two end stations of the circuit.
S1 is always an end station which is locally attached.
S2 may be locally attached or remote. If it is locally
attached, the circuit will be represented by two rows indexed
by (A, B) and (B, A) where A & B are the relevant MACs/SAPs.
The table may be used to store the causes of disconnection of
circuits. It is recommended that the oldest disconnected
circuit entry be removed from this table when the memory
space of disconnected circuits is needed."
::= { dlswCircuit 1 }
dlswCircuitEntry OBJECT-TYPE
SYNTAX DlswCircuitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"the list of circuit information"
INDEX { dlswCircuitS1CircuitId }
::= { dlswCircuitTable 1 }
DlswCircuitEntry ::=
SEQUENCE {
dlswCircuitS1CircuitId
Integer32,
dlswCircuitS1Mac
MacAddressNC,
dlswCircuitS1Sap
OCTET STRING,
dlswCircuitS2Mac
MacAddressNC,
dlswCircuitS2Sap
OCTET STRING,
dlswCircuitS1IfIndex
Integer32,
dlswCircuitS1Ifname
DisplayString,
dlswCircuitS1DlcType
DlcType,
dlswCircuitS2Location
EndStationLocation,
dlswCircuitS2TAddress
IpAddress,
dlswCircuitS2CircuitId
Integer32,
dlswCircuitOrigin
INTEGER,
dlswCircuitEntryTime
TimeTicks,
dlswCircuitStateTime
TimeTicks,
dlswCircuitState
INTEGER,
dlswCircuitPriority
INTEGER,
dlswCircuitFCSendGrantedUnits
Integer32,
dlswCircuitFCSendCurrentWndw
Integer32,
dlswCircuitFCRecvGrantedUnits
Integer32,
dlswCircuitFCRecvCurrentWndw
Integer32,
dlswCircuitFCLargestRecvGranted
Gauge32,
dlswCircuitFCLargestSendGranted
Gauge32
}
dlswCircuitS1CircuitId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The Circuit ID assigned by this DLSw node to this circuit.
The first four octets are the DLC port Id, and
the second four octets are the Data Link Correlator.
If the DLSw SSP was not used to establish this circuit,
the value will be a string of zero length."
::= { dlswCircuitEntry 1 }
dlswCircuitS1Mac OBJECT-TYPE
SYNTAX MacAddressNC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC Address of End Station 1 (S1) used for this circuit."
::= { dlswCircuitEntry 2 }
dlswCircuitS1Sap OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SAP at End Station 1 (S1) used for this circuit."
::= { dlswCircuitEntry 3 }
dlswCircuitS2Mac OBJECT-TYPE
SYNTAX MacAddressNC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC Address of End Station 2 (S2) used for this circuit."
::= { dlswCircuitEntry 4 }
dlswCircuitS2Sap OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SAP at End Station 2 (S2) used for this circuit."
::= { dlswCircuitEntry 5 }
dlswCircuitS1IfIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifEntry index of the local interface through which S1
can be reached."
::= { dlswCircuitEntry 6 }
dlswCircuitS1Ifname OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the interface whose Ifdex is dlswCircuitS1IfIndex."
::= { dlswCircuitEntry 7 }
dlswCircuitS1DlcType OBJECT-TYPE
SYNTAX DlcType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DLC protocol in use between the DLSw node and S1."
::= { dlswCircuitEntry 8 }
dlswCircuitS2Location OBJECT-TYPE
SYNTAX EndStationLocation
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The location of End Station 2 (S2).
If the location of End Station 2 is local, the
interface information will be available in the
conceptual row whose S1 and S2 are the S2 and
the S1 of this conceptual row, respectively."
::= { dlswCircuitEntry 9 }
dlswCircuitS2TAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the location of End Station 2 is remote,
this object contains the address of the partner
DLSw, else it will be an OCTET STRING of zero length."
::= { dlswCircuitEntry 10 }
dlswCircuitS2CircuitId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Circuit ID assigned to this circuit by the partner
DLSw node. The first four octets are the DLC port Id, and
the second four octets are the Data Link Correlator.
If the DLSw SSP was not used to establish this circuit,
the value will be a string of zero length."
::= { dlswCircuitEntry 11 }
dlswCircuitOrigin OBJECT-TYPE
SYNTAX INTEGER {
s1 (1),
s2 (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies which of the two end stations
initiated the establishment of this circuit."
::= { dlswCircuitEntry 12 }
dlswCircuitEntryTime OBJECT-TYPE
SYNTAX TimeTicks
UNITS "hundredths of a second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time (in hundredths of a second) since this
circuit table conceptual row was created."
::= { dlswCircuitEntry 13 }
dlswCircuitStateTime OBJECT-TYPE
SYNTAX TimeTicks
UNITS "hundredths of a second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time (in hundredths of a second) since this
circuit entered the current state."
::= { dlswCircuitEntry 14 }
dlswCircuitState OBJECT-TYPE
SYNTAX INTEGER {
disconnected (1),
circuitStart (2),
resolvePending (3),
circuitPending (4),
circuitEstablished (5),
connectPending (6),
contactPending (7),
connected (8),
disconnectPending (9),
haltPending (10),
haltPendingNoack (11),
circuitRestart (12),
restartPending (13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of this circuit. The agent, implementation
specific, may choose to keep entries for some period of time
after circuit disconnect, so the manager can gather the time
and cause of disconnection.
While all of the specified values may be returned from a GET
operation, the only SETable value is `disconnectPending'.
When this value is set, DLSw should perform the appropriate
action given its previous state (e.g., send HALT_DL if the
state was `connected') to bring the circuit down to the
`disconnected' state. Both the partner DLSw and local end
station(s) should be notified as appropriate.
This MIB provides no facility to re-establish a disconnected
circuit, because in DLSw this should be an end station-driven
function."
::= { dlswCircuitEntry 15 }
dlswCircuitPriority OBJECT-TYPE
SYNTAX INTEGER {
unsupported (1),
low (2),
medium (3),
high (4),
highest (5)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The transmission priority of this circuit as understood by
this DLSw node. This value is determined by the two DLSw
nodes at circuit startup time. If this DLSw node does not
support DLSw circuit priority, the value `unsupported' should
be returned."
::= { dlswCircuitEntry 16 }
--==================================================================
-- Pacing Objects:
-- These objects are applicable if DLSw is using the SSP circuit
-- pacing protocol to control the flow between the two data links
-- in this circuit.
--==================================================================
dlswCircuitFCSendGrantedUnits OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of paced SSP messages that this DLSw is currently
authorized to send on this circuit before it must stop and
wait for an additional flow control indication from the
partner DLSw.
The value zero should be returned if this circuit is not
running the DLSw pacing protocol."
::= { dlswCircuitEntry 17 }
dlswCircuitFCSendCurrentWndw OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current window size that this DLSw is using in its role
as a data sender. This is the value by which this DLSw would
increase the number of messages it is authorized to send, if
it were to receive a flow control indication with the bits
specifying `repeat window'.
The value zero should be returned if this circuit is not
running the DLSw pacing protocol."
::= { dlswCircuitEntry 18 }
dlswCircuitFCRecvGrantedUnits OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of paced SSP messages that this DLSw has
authorized the partner DLSw to send on this circuit before
the partner DLSw must stop and wait for an additional flow
control indication from this DLSw.
The value zero should be returned if this circuit is not
running the DLSw pacing protocol."
::= { dlswCircuitEntry 19 }
dlswCircuitFCRecvCurrentWndw OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current window size that this DLSw is using in its role
as a data receiver. This is the number of additional paced
SSP messages that this DLSw would be authorizing its DLSw
partner to send, if this DLSw were to send a flow control
indication with the bits specifying `repeat window'.
The value zero should be returned if this circuit is not
running the DLSw pacing protocol."
::= { dlswCircuitEntry 20 }
dlswCircuitFCLargestRecvGranted OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The largest receive window size granted by this DLSw during
the current activation of this circuit. This is not the
largest number of messages granted at any time, but the
largest window size as represented by FCIND operator bits.
The value zero should be returned if this circuit is not
running the DLSw pacing protocol."
::= { dlswCircuitEntry 21 }
dlswCircuitFCLargestSendGranted OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The largest send (with respect to this DLSw) window size
granted by the partner DLSw during the current activation of
this circuit.
The value zero should be returned if this circuit is not
running the DLSw pacing protocol."
::= { dlswCircuitEntry 22 }
--==================================================================
-- DLSW SDLC EXTENSION
--==================================================================
dlswSdlcPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlswSdlcPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table defines parameters for the interfaces with the
encapunation of SDLC."
::= { dlswSdlc 1 }
dlswSdlcPortEntry OBJECT-TYPE
SYNTAX DlswSdlcPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information of table"
INDEX { ifIndex }
::= { dlswSdlcPortTable 1 }
DlswSdlcPortEntry ::=
SEQUENCE {
dlswSdlcPortSerialName
DisplayString,
dlswSdlcPortEncap
INTEGER,
dlswSdlcPortRole
INTEGER,
dlswSdlcPortVmac
MacAddressNC,
dlswSdlcPortHoldq
Integer32,
dlswSdlcPortK
Integer32,
dlswSdlcPortModule
INTEGER,
dlswSdlcPortN1
Integer32,
dlswSdlcPortN2
Integer32,
dlswSdlcPortPollPauseTimer
Integer32,
dlswSdlcPortSimultaneousEnable
INTEGER,
dlswSdlcPortT1
Integer32,
dlswSdlcPortT2
Integer32,
dlswSdlcPortNrziEncoding
INTEGER,
dlswSdlcPortIdleMarkEnable
INTEGER
}
dlswSdlcPortSerialName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of serial port. "
::= { dlswSdlcPortEntry 1 }
dlswSdlcPortEncap OBJECT-TYPE
SYNTAX INTEGER {
sdlc(1),
ppp(2),
other(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The encapunation of the interface. "
::= { dlswSdlcPortEntry 2 }
dlswSdlcPortRole OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
seconday(2),
norole(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SDLC role of interface. "
DEFVAL { norole }
::= { dlswSdlcPortEntry 3 }
dlswSdlcPortVmac OBJECT-TYPE
SYNTAX MacAddressNC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define virtual mac address. "
::= { dlswSdlcPortEntry 4 }
dlswSdlcPortHoldq OBJECT-TYPE
SYNTAX Integer32 (20..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Size of hold queue."
DEFVAL { 50 }
::= { dlswSdlcPortEntry 5 }
dlswSdlcPortK OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Size of local send window. "
DEFVAL { 7 }
::= { dlswSdlcPortEntry 6 }
dlswSdlcPortModule OBJECT-TYPE
SYNTAX INTEGER {
m8(8),
m128(128)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Size of modulus. "
DEFVAL { m8 }
::= { dlswSdlcPortEntry 7 }
dlswSdlcPortN1 OBJECT-TYPE
SYNTAX Integer32 (1..17680)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max number of bits for incoming frames. "
DEFVAL { 265 }
::= { dlswSdlcPortEntry 8 }
dlswSdlcPortN2 OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of timers to retry an operation. "
DEFVAL { 20 }
::= { dlswSdlcPortEntry 9 }
dlswSdlcPortPollPauseTimer OBJECT-TYPE
SYNTAX Integer32 (1..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time between polls for each secondary SDLC station.
The unit is thousandth of a second. "
DEFVAL { 100 }
::= { dlswSdlcPortEntry 10 }
dlswSdlcPortSimultaneousEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disenable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activate SDLC two-way simultaneous mode. "
DEFVAL { 1 }
::= { dlswSdlcPortEntry 11 }
dlswSdlcPortT1 OBJECT-TYPE
SYNTAX Integer32 (1..60000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time to wait for a reply to a frame. "
DEFVAL { 3000 }
::= { dlswSdlcPortEntry 12 }
dlswSdlcPortT2 OBJECT-TYPE
SYNTAX Integer32 (1..60000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time to wait for a reply used by secondary station. "
DEFVAL { 500 }
::= { dlswSdlcPortEntry 13 }
dlswSdlcPortNrziEncoding OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disenable(2)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Set line code to nrzi encoding mode. "
DEFVAL { enable }
::= { dlswSdlcPortEntry 14 }
dlswSdlcPortIdleMarkEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disenable(2)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Idle in mark mode. "
DEFVAL { enable }
::= { dlswSdlcPortEntry 15 }
dlswSdlcLsTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlswSdlcLsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table defines the virtual MAC addresses for those
SDLC link stations that participate in data link switching."
::= { dlswSdlc 2 }
dlswSdlcLsEntry OBJECT-TYPE
SYNTAX DlswSdlcLsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information of table"
INDEX { ifIndex, dlswSdlcLsAddress}
::= { dlswSdlcLsTable 1 }
DlswSdlcLsEntry ::=
SEQUENCE {
dlswSdlcLsAddress
Integer32,
dlswSdlcLsLocalId
Integer32,
dlswSdlcLsRemoteMac
MacAddressNC,
dlswSdlcLsSsap
Integer32,
dlswSdlcLsDsap
Integer32,
dlswSdlcLsStatus
EntryStatus
}
dlswSdlcLsAddress OBJECT-TYPE
SYNTAX Integer32 (1..254)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Define SDLC address. "
::= { dlswSdlcLsEntry 1 }
dlswSdlcLsLocalId OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The value is XID. "
::= { dlswSdlcLsEntry 2 }
dlswSdlcLsRemoteMac OBJECT-TYPE
SYNTAX MacAddressNC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MAC address to which DLSw should attempt to connect
this link station. If this information is not available,
a length of zero for this object should be returned "
::= { dlswSdlcLsEntry 3 }
dlswSdlcLsSsap OBJECT-TYPE
SYNTAX Integer32 (1..254)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Source SAP of partner. "
::= { dlswSdlcLsEntry 4 }
dlswSdlcLsDsap OBJECT-TYPE
SYNTAX Integer32 (1..254)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Destination SAP of partner. "
::= { dlswSdlcLsEntry 5 }
dlswSdlcLsStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object is used by the manager to create
or delete the row entry in the DlswSdlcLsTable
following the EntryStatus textual convention."
::= { dlswSdlcLsEntry 6 }
--==================================================================
-- DLSW LLC2 EXTENSION
--==================================================================
dlswLlc2PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlswLlc2PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table defines parameters for the interfaces with the
encapunation of Llc2."
::= { dlswLlc2 1 }
dlswLlc2PortEntry OBJECT-TYPE
SYNTAX DlswLlc2PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information of table"
INDEX { ifIndex ,dlswBridgeIfBriGru}
::= { dlswLlc2PortTable 1 }
DlswLlc2PortEntry ::=
SEQUENCE {
dlswLLC2PortAckDelayTime
Integer32,
dlswLLC2PortAckMax
Integer32,
dlswLLC2PortLocalWnd
Integer32,
dlswLLC2PortModulus
INTEGER,
dlswLLC2PortN2
Integer32,
dlswLLC2PortT1
Integer32,
dlswLLC2PortTbusyTime
Integer32,
dlswLLC2PortTpfTime
Integer32,
dlswLLC2PortTrejTime
Integer32,
dlswLLC2PortTxqMax
Integer32
}
dlswLLC2PortAckDelayTime OBJECT-TYPE
SYNTAX Integer32 (1..60000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max time allows I-frames incoming without replay ACK. "
DEFVAL { 100 }
::= { dlswLlc2PortEntry 1 }
dlswLLC2PortAckMax OBJECT-TYPE
SYNTAX Integer32 (1..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max number of I-frames received before ACK. "
DEFVAL { 3 }
::= { dlswLlc2PortEntry 2 }
dlswLLC2PortLocalWnd OBJECT-TYPE
SYNTAX Integer32 (1..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max number of I-frames to send before received ACK. "
DEFVAL { 7 }
::= { dlswLlc2PortEntry 3 }
dlswLLC2PortModulus OBJECT-TYPE
SYNTAX INTEGER {
m8(8),
m128(128)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Modulus of LLC2. "
DEFVAL { m128 }
::= { dlswLlc2PortEntry 4 }
dlswLLC2PortN2 OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Retry times of operations. "
DEFVAL { 20 }
::= { dlswLlc2PortEntry 5 }
dlswLLC2PortT1 OBJECT-TYPE
SYNTAX Integer32 (1..60000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Waiting for ACK time after sent a I-frame. "
DEFVAL { 200 }
::= { dlswLlc2PortEntry 6 }
dlswLLC2PortTbusyTime OBJECT-TYPE
SYNTAX Integer32 (1..60000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Waiting time while other LLC2 station is in busy state. "
DEFVAL { 300 }
::= { dlswLlc2PortEntry 7 }
dlswLLC2PortTpfTime OBJECT-TYPE
SYNTAX Integer32 (1..60000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Waiting time after a P frame is sent. "
DEFVAL { 500 }
::= { dlswLlc2PortEntry 8 }
dlswLLC2PortTrejTime OBJECT-TYPE
SYNTAX Integer32 (1..60000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Waiting time after a REJ frame is sent. "
DEFVAL { 500 }
::= { dlswLlc2PortEntry 9 }
dlswLLC2PortTxqMax OBJECT-TYPE
SYNTAX Integer32 (20..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Queue for sending llc2 I-frames. "
DEFVAL { 50 }
::= { dlswLlc2PortEntry 10 }
--==================================================================
-- TRAP GENERATION CONTROL
--==================================================================
dlswTrapControl OBJECT IDENTIFIER ::= { dlswNode 20}
dlswTrapCntlState OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It is used to indicate whether the DLSw is permitted to emit traps. "
::= { dlswTrapControl 1 }
--==================================================================
-- NOTIFICATIONS, i.e., TRAP DEFINITIONS
--==================================================================
dlswTraps OBJECT IDENTIFIER ::= { dlsw 8 }
-- ==================================================================
-- This section defines the well-known notifications sent by
-- DLSW agents.
-- Care must be taken to insure that no particular notification
-- is sent to a single receiving entity more often than once
-- every five seconds.
--
-- Traps includes:
-- (1) Partner rejected (capEx rejection, not in partner list, etc.)
-- (2) DLSw protocol violation (e.g., window size violation, etc.)
-- (3) Transport connection up/down
-- (4) Circuit up/down
-- ==================================================================
--
dlswTrapsV2 OBJECT IDENTIFIER ::= { dlswTraps 0 }
dlswTrapTConnPartnerReject NOTIFICATION-TYPE
OBJECTS { dlswRemotePeerAddr }
STATUS current
DESCRIPTION
"This trap is sent each time a transport connection
is rejected by a partner DLSw during Capabilities
Exchanges. The emission of this trap is controlled
by dlswTrapCntlState."
::= { dlswTrapsV2 1 }
dlswTrapTConnChangeState NOTIFICATION-TYPE
OBJECTS { dlswRemotePeerAddr, dlswRemotePeerLinkState }
STATUS current
DESCRIPTION
"This trap is sent each time a transport connection
changes state. The emission of this trap
is controlled by dlswTrapCntlState."
::= { dlswTrapsV2 2 }
dlswTrapCircuitChangeState NOTIFICATION-TYPE
OBJECTS { dlswCircuitS1CircuitId,dlswCircuitState,dlswCircuitS1Mac,
dlswCircuitS1Sap,dlswCircuitS2Mac, dlswCircuitS2Sap
}
STATUS current
DESCRIPTION
"This trap is sent each time a circuit change
state. The emission of this trap is controlled by
dlswTrapCntlState."
::= { dlswTrapsV2 3 }
END