-- Copyright (C) 2002 by HUAWEI 3Com TECHNOLOGIES. All rights reserved.
--
-- Description: power over ethernet extend mib
-- Reference: POWER-ETHERNET-MIB
-- Version: V1.5
-- History:
-- V1.0 2004-07-24 Created by Gaolong
-- V1.1 2004-09-08 Update file by Gaolong for some syntax errors.
-- V1.2 2004-11-19 Update file by liuhongxu for poe need.
-- add h3cMainPsePriorityMode¡¢h3cPsePowerMaxValue¡¢
-- h3cpsePDChangNotification adjust the objects' sequence of
-- h3cPsePortTable and h3cMainPseTable add the description
-- of MANDATORY-GROUPS in h3cPseCompliance.
-- V1.3 2004-12-16 Update file by liuhongxu for poe profile
-- add h3cPsePortProfile, h3cPseProfilesTable
-- change the name of h3cPseProfileIndex add
-- h3cPseProfileApplyNum. adjust the format of this mib.
-- V1.4 2005-03-29 Update file by Wangzhaoyan for poe pow need.
-- add h3cPOEPowerObjects, h3cPOEThresholdLimitObjs,
-- h3cPOESupModuleInfoObjs, h3cPOEDCOutStateObjects,
-- h3cPOEDCDCOutInfoObjects, h3cPOEACSwitchStateModuleObjs,
-- h3cPOEInCurStateObjects, h3cPOEAlarmStateObjects and the
-- sub-nodes. add 17 traps change the node name from
-- h3cpsePDChangNotification to h3cpsePDChangeNotification
-- change some detail as the suggestion from Wangyingxia and
-- Yangyang. adjust the format of this mib.
-- V1.5 2005-11-21 Update file by Liweizhen for controling the power-management
-- policy of PSE or PD. Add h3cPsePolicyMode, h3cPDPolicyMode,
-- h3cMainPsePowerPriority.
-- Delete some description of h3cPsePortProfileIndex node.
-- Change the description of h3cPseProfilePowerMode node.
-- Change SYNTAX OCTET STRING range for the following nodes:
-- h3cPOEPowerType, h3cPOESupervisionModuleName,
-- h3cPOESMFactorName, h3cPOEModuleHardVerInfo.
-- Adjust the format of this mib.
-- =================================================================
A3COM-HUAWEI-POWER-ETH-EXT-MIB DEFINITIONS ::= BEGIN
IMPORTS
h3cCommon
FROM A3COM-HUAWEI-OID-MIB
pethPsePortGroupIndex, pethPsePortIndex,
pethMainPseGroupIndex, pethPsePortDetectionStatus
FROM POWER-ETHERNET-MIB
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, RowStatus
FROM SNMPv2-TC;
h3cPowerEthernetExt MODULE-IDENTITY
LAST-UPDATED "200407261023Z" -- July 26, 2004 at 10:23 GMT
ORGANIZATION
"Organization."
CONTACT-INFO
"Contact-info."
DESCRIPTION
"Description."
::= { h3cCommon 14 }
--
-- Node definitions
--
h3cPsePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The indexing scheme is taken form that used by
the IETF Power MIB. The same indexing scheme is
used to give continuity in behaviour between
that standard and this extensions definitioin."
::= { h3cPowerEthernetExt 1 }
h3cPsePortEntry OBJECT-TYPE
SYNTAX H3cPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The pethPsePortGroupIndex is imported from the IETF Power MIB
and uniquely identifies the group containing the port to which
power ethernet PSE is connected. Group means (box in the stack,
module in a rack).
The pethPsePortPowerIndex is imported from the IETF Power MIB
and uniquely identifies the power ethernet PSE port within group
pethPseGroupIndex to which the power Ethernet PSE entry is
connected. This value will match the local port number on a
switch."
INDEX { pethPsePortGroupIndex, pethPsePortIndex }
::= { h3cPsePortTable 1 }
H3cPsePortEntry ::=
SEQUENCE {
h3cPsePortFaultDescription
DisplayString,
h3cPsePortPeakPower
Integer32,
h3cPsePortAveragePower
Integer32,
h3cPsePortCurrentPower
Integer32,
h3cPsePortPowerLimit
Integer32,
h3cPsePortProfileIndex
Integer32
}
h3cPsePortFaultDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object supports the fault category of the IETF Power MIB [1]
pethPsePortDetectionStatus object. A textual description
containing more information about the nature of this fault is
provided by this object. Typically this will detail the precise
PoE hardware state which is causing the pethPsePortDetectionStatus
object to be in the 'fault' state.
It is a DisplayString of up to 255 characters."
::= { h3cPsePortEntry 2 }
h3cPsePortPeakPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the peak power which has been consumed by
the port. It is defined as the highest measured value of power
in milliWatts that has been consumed by the port. Its value
is only reset when link is lost, the port is PoE disabled or
when it is manually reset by the user asspecified below.
It is a read/write integer value with units of milliWatts.
Writing a value of zero to this object resets its value
to zero. Writing any other value to this object has no
effect on its value and an error is returned."
::= { h3cPsePortEntry 3 }
h3cPsePortAveragePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the average power which has been consumed
by the port. This object is a read/write integer value with
units of milliWatts. Writing a value of zero to this object
resets its value to zero. Writing any other value to this
object has no effect on its value and an error is returned."
::= { h3cPsePortEntry 4 }
h3cPsePortCurrentPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the power currently being consumed by the port.
It is a read only integer value with units of milliWatts."
::= { h3cPsePortEntry 5 }
h3cPsePortPowerLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the power limit set for this port.
The PSE will not supply more than this level of power to the
specified port.
It is a read/write integer value with units of milliWatts."
::= { h3cPsePortEntry 6 }
h3cPsePortProfileIndex OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the power profile which is currently associated
with this port. This object references the corresponding
h3cPseProfileIndex object in the power profiles table. A
value of zero is a special case and indicates that no
power profile is currently associated with this port. When
h3cPseProfileIndex is set to an index of existent profile,
pethPsePortPowerPairs, pethPsePortPowerPriority,
pethPsePortAdminEnable and h3cPsePortPowerLimit will be
set to the same as corresponding value. PethPsePortPowerPairs,
pethPsePortPowerPriority and pethPsePortAdminEnable are objects
of rfc3621-Power-Ethernet.mib."
::= { h3cPsePortEntry 7 }
h3cMainPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { h3cPowerEthernetExt 2 }
h3cMainPseEntry OBJECT-TYPE
SYNTAX H3cMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The pethMainPseGroupIndex is imported from the IETF Power MIB
and uniquely identifies the group containing the port to which
power ethernet PSE is connected. Group means (box in the stack,
module in a rack) and the value 1 MUST be used for non-modular
devices."
INDEX { pethMainPseGroupIndex }
::= { h3cMainPseTable 1 }
H3cMainPseEntry ::=
SEQUENCE {
h3cMainGuaranteedPowerRemaining
Integer32,
h3cMainPsePeakPower
Integer32,
h3cMainPseAveragePower
Integer32,
h3cMainPsePowerLimit
Integer32,
h3cMainPsePriorityMode
INTEGER,
h3cMainPseLegacy
INTEGER,
h3cMainPsePowerPriority
INTEGER
}
h3cMainPsePowerLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the power limit set for the unit as a whole.
The PoE unit will already have a nominal power defined by the
IETF Power MIB [1] pethMainPsePower object. This OPTIONAL object
specifies a further limit to this nominal power value. This may
be useful to control the thermals of the unit, or for internal
testing purposes. One possible use for this object may be to lower
the power consumption of the unit if one or more of the internal
fans have broken. It is a read/write integer value with units of
Watts (note - Watts is chosen instead of milliWatts here since
the IETF Power MIB [1] measures unit based parameters, such as
the pethMainPsePower object, in units of Watts)."
::= { h3cMainPseEntry 1 }
h3cMainPseAveragePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the average power which has been consumed
by the port. It is a read/write integer value with units of
Watts (note - Watts is chosen instead of milliWatts here since
the IETF Power MIB [1] measures unit based parameters, such as
the pethMainPsePower object, in units of Watts). Writing a value
of zero to this object resets its value to zero. Writing any
other value to this object has no effect on its value and an error
is returned."
::= { h3cMainPseEntry 2 }
h3cMainPsePeakPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the peak power which has been consumed for PoE.
It is defined as the highest measured value of power in milliWatts
that has been consumed at any one point in time by the sum of the PoE
ports. Its value is only reset when the unit is powered on or when
it is manually reset by the user as specifiedbelow. It is a read/write
integer value with units of Watts (note - Watts is chosen instead of
milliWatts here since the IETF Power MIB [1] measures unit based
parameters, such as the pethMainPsePower object, in units of Watts).
Writing a value of zero to this object resets its value to zero.
Writing any other value to this object has noeffect on its value
and an error is returned."
::= { h3cMainPseEntry 3 }
h3cMainGuaranteedPowerRemaining OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the amount of power remaining in the guaranteed
power pool. Each time a port is placed into guaranteed mode it
reserves a set amount of power out of the total guaranteed power
pool for the system. This intention of this object is to give the
client of this MIB (whether that be the CLI or the Web interface or
the end user) an indication of how many ports can still be placed
into guaranteed mode. It is a read only integer value with units of
Watts(note - Watts is chosen instead of milliWatts here since the
IETF Power MIB [1] measures unit based parameters,such as the
pethMainPsePower object, in units of Watts)."
::= { h3cMainPseEntry 4 }
h3cMainPsePriorityMode OBJECT-TYPE
SYNTAX INTEGER {
disconnection(0),
non-disconnection(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the priority mode on slot which must be
enabled firstly. When a new board is inserted, and the power is
over-load, a value of disconnection(0) means that the power will
stop supply to the low priority slot ; A value of non-disconnection(1)
means that the slot still supply when a new board is inserted, and
the power is over-load too."
::= { h3cMainPseEntry 5 }
h3cMainPseLegacy OBJECT-TYPE
SYNTAX INTEGER {
enable(0),
disable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the legacy mode on slot which must be enabled
firstly. Legacy mode: standard or nonstandard PD detection mode."
::= { h3cMainPseEntry 6 }
h3cMainPsePowerPriority OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
high(2),
low(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the priority of the PSE. The priority
will be used by the PSE policy to prevent from power overloading.
If the priority of PSE is set to critical, the PSE will turn into
guaranteed mode. The priority could be used by a control mechanism
that prevents power overloading by disconnecting PSEs with lower
power priority. PSEs that connect devices critical to the
application should be set to higher priority."
::= { h3cMainPseEntry 7 }
-- Power Profile PSE table
h3cPseProfilesTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPseProfilesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of objects representing a set of power profiles.
Power profiles can be applied to PoE ports, which have the
effect of automatically setting the priority, power limit
and PoE enable MIB objects to the values specified in the
power profile."
::= { h3cPowerEthernetExt 7 }
h3cPseProfilesEntry OBJECT-TYPE
SYNTAX H3cPseProfilesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that display and control the Main power of a PSE."
INDEX { h3cPseProfileIndex }
::= { h3cPseProfilesTable 1 }
H3cPseProfilesEntry ::= SEQUENCE {
h3cPseProfileIndex Integer32,
h3cPseProfileName DisplayString,
h3cPseProfilePowerMode INTEGER,
h3cPseProfilePowerLimit Integer32,
h3cPseProfilePriority INTEGER,
h3cPseProfilePairs INTEGER,
h3cPseProfileApplyNum Integer32,
h3cPseProfileRowStatus RowStatus
}
h3cPseProfileIndex OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the profile. This uniquely allow the profile to be
identified."
::= { h3cPseProfilesEntry 1 }
h3cPseProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..15))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Assigns the profile a name with which the settings
can be assiciated with. For example, 'NBX Phone'."
::= { h3cPseProfilesEntry 2 }
h3cPseProfilePowerMode OBJECT-TYPE
SYNTAX INTEGER {
powerDisabled (1),
powerEnabled (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The power mode associated with this power profile. There
are two possible power modes as follows: powerDisabled,
powerEnabled. When a power profile is applied to a PSE port,
this value dictates the settings of the ports pethPsePortPowerPriority
and pethPsePortAdminEnable objects."
::= { h3cPseProfilesEntry 3 }
h3cPseProfilePowerLimit OBJECT-TYPE
SYNTAX Integer32 (0..15400)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The power limit to be applied to the ports h3cPsePortPowerLimit
object when the profile is applied to the PSE port. Expressed in
milliWatts."
::= { h3cPseProfilesEntry 4 }
h3cPseProfilePriority OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
high(2),
low(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the priority of the port from the point of
view of a power management algorithm. The priority that is set
by this variable could be used by a control mechanism that
prevents over current situations by disconnecting first ports
with lower power priority. Ports that connect devices critical
to the operation of the network - like the E911 telephones
ports - should be set to higher priority."
::= { h3cPseProfilesEntry 5 }
h3cPseProfilePairs OBJECT-TYPE
SYNTAX INTEGER {
signal(1),
spare(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Describes or controls the pairs in use. If the value of
pethPsePortPowerPairsControl is true, this object is writable.
A value of signal(1) means that the signal pairs only are in use.
A value of spare(2) means that the spare pairs only are in use."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs"
::= { h3cPseProfilesEntry 6 }
h3cPseProfileApplyNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of this profile which has been applied.
If h3cPseProfileApplyNum is not zero, user can't
change the current line."
::= { h3cPseProfilesEntry 7 }
h3cPseProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this classifier.
If h3cPseProfileApplyNum is not zero, user can't
delete the current line."
::= { h3cPseProfilesEntry 8 }
h3cPseAutoDetectActive OBJECT-TYPE
SYNTAX INTEGER
{
notSupported(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies whether the device auto-detection feature is
active. If this object is set to Active, and a known powered device
is detected, then the port will automatically switch to Auto-Guaranteed
mode. This is a stackwide object (ie. it is not referenced by
group index)."
::= { h3cPowerEthernetExt 3 }
h3cPsePowerMaxValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the max poe power for lanswitch.
The value should between the power currently and the max power."
::= { h3cPowerEthernetExt 5 }
h3cPsePolicyMode OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
priority(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PSE policy only applies to the situation that when a new
board (PSE) is inserted, and the power is overload.
A value of priority(2) means that the power will stop supplying
to the low priority PSE. About PSE priority, please refer to
h3cMainPsePowerPriority. A value of disabled(1) means that the
power will stop supplying to the new inserted PSE. The default
value of this object is disabled(1)."
::= { h3cPowerEthernetExt 9 }
h3cPDPolicyMode OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
priority(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PD policy only applies to the situation that when a new
PD is inserted, and the power of PSE is overload.
A value of priority(2) means that the power will stop supplying
to the low priority port PD. About port priority, please refer
to pethPsePortPowerPriority. A value of disabled(1) means that
the slot stop supplying to the new inserted PD. The default
value of this object is disabled(1)."
::= { h3cPowerEthernetExt 10 }
h3cpseportNotification OBJECT IDENTIFIER ::= { h3cPowerEthernetExt 6 }
-- Notification Control Objects
h3cpsePDChangeNotification NOTIFICATION-TYPE
OBJECTS { pethPsePortDetectionStatus }
STATUS current
DESCRIPTION
"This notification indicates if PD has been inserted or pulled out."
::= { h3cpseportNotification 1 }
h3cPOEDisconnectNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEAlarmModuleInfoIndex, h3cPOEModuleDisconnect }
STATUS current
DESCRIPTION
"This notification indicates the POE power module does not disconnect."
::= { h3cpseportNotification 2 }
h3cPOEInputErrorNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEAlarmModuleInfoIndex, h3cPOEModuleInputError }
STATUS current
DESCRIPTION
"This notification indicates the POE power module input error."
::= { h3cpseportNotification 3 }
h3cPOEOutputErrorNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEAlarmModuleInfoIndex, h3cPOEModuleOutputError }
STATUS current
DESCRIPTION
"This notification indicates the POE power module output error."
::= { h3cpseportNotification 4 }
h3cPOEOverVoltageNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEAlarmModuleInfoIndex, h3cPOEModuleOverVoltage }
STATUS current
DESCRIPTION
"This notification indicates the POE power module overruns the
voltage limit."
::= { h3cpseportNotification 5 }
h3cPOEOverTempNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEAlarmModuleInfoIndex, h3cPOEModuleOverTemp }
STATUS current
DESCRIPTION
"This notification indicates the POE power module overruns the
temperature limit."
::= { h3cpseportNotification 6 }
h3cPOEFanErrorNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEAlarmModuleInfoIndex, h3cPOEModuleFanError }
STATUS current
DESCRIPTION
"This notification indicates the POE power module fan error."
::= { h3cpseportNotification 7 }
h3cPOEModuleShutdownNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEAlarmModuleInfoIndex, h3cPOEModuleShutdown }
STATUS current
DESCRIPTION
"This notification indicates the POE power module is closed."
::= { h3cpseportNotification 8 }
h3cPOECurRestrictedNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEAlarmModuleInfoIndex, h3cPOEModuleCurRestricted }
STATUS current
DESCRIPTION
"This notification indicates the POE power module current is restricted."
::= { h3cpseportNotification 9 }
h3cPOEACSwitchNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEACSwitchStateIndex, h3cPOEACSwitchState }
STATUS current
DESCRIPTION
"This notification indicates the AC input switch alarm of this POE power."
::= { h3cpseportNotification 10 }
h3cPOEACInCurANotification NOTIFICATION-TYPE
OBJECTS { h3cPOEInCurAState }
STATUS current
DESCRIPTION
"This notification indicates the AC input current A alarm state of
this POE power."
::= { h3cpseportNotification 11 }
h3cPOEACInCurBNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEInCurBState }
STATUS current
DESCRIPTION
"This notification indicates the AC input current B alarm state of
this POE power."
::= { h3cpseportNotification 12 }
h3cPOEACInCurCNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEInCurCState }
STATUS current
DESCRIPTION
"This notification indicates the AC input current C alarm state of
this POE power."
::= { h3cpseportNotification 13 }
h3cPOEACSwitchVolABNotification NOTIFICATION-TYPE
OBJECTS { h3cPOESwitchStateVolExIndex, h3cPOESwitchStateInVolAB}
STATUS current
DESCRIPTION
"This notification indicates the AC input voltage AB alarm state of
this POE power."
::= { h3cpseportNotification 14 }
h3cPOEACSwitchVolBCNotification NOTIFICATION-TYPE
OBJECTS { h3cPOESwitchStateVolExIndex, h3cPOESwitchStateInVolBC}
STATUS current
DESCRIPTION
"This notification indicates the AC input voltage BC alarm state of
this POE power."
::= { h3cpseportNotification 15 }
h3cPOEACSwitchVolCANotification NOTIFICATION-TYPE
OBJECTS { h3cPOESwitchStateVolExIndex, h3cPOESwitchStateInVolCA }
STATUS current
DESCRIPTION
"This notification indicates the AC input voltage CA alarm state of
this POE power."
::= { h3cpseportNotification 16 }
h3cPOEDCOutVolNotification NOTIFICATION-TYPE
OBJECTS { h3cPOEDCOutStateIndex, h3cPOEDCOutDCVolAlarm }
STATUS current
DESCRIPTION
"This notification indicates the DC output alarm of this POE power."
::= { h3cpseportNotification 17 }
h3cPOEShutdownNotification NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This notification indicates the whole POE power has been shutdown."
::= { h3cpseportNotification 18 }
h3cPseComformance OBJECT IDENTIFIER ::= { h3cPowerEthernetExt 4 }
h3cPseCompliances OBJECT IDENTIFIER ::= { h3cPseComformance 1 }
h3cPseCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Description."
MODULE -- this module
MANDATORY-GROUPS { h3cPsePortGroup,
h3cMainPseGroup,
h3cPseScalarGroup,
h3cPsePDNotificationGroup
}
GROUP h3cPseProfilesGroup
DESCRIPTION
"This group is mandatory only for executing POE commands as a batch."
::= { h3cPseCompliances 1 }
h3cPseGroup OBJECT IDENTIFIER ::= { h3cPseComformance 2 }
h3cPsePortGroup OBJECT-GROUP
OBJECTS { h3cPsePortProfileIndex, h3cPsePortPowerLimit, h3cPsePortCurrentPower,
h3cPsePortAveragePower, h3cPsePortPeakPower, h3cPsePortFaultDescription,
h3cMainPsePriorityMode
}
STATUS current
DESCRIPTION
"A collection of objects should be supported at the same time."
::= { h3cPseGroup 1 }
h3cMainPseGroup OBJECT-GROUP
OBJECTS { h3cMainPsePowerLimit, h3cMainPseAveragePower, h3cMainPsePeakPower,
h3cMainGuaranteedPowerRemaining }
STATUS current
DESCRIPTION
"A collection of objects should be supported at the same time."
::= { h3cPseGroup 2 }
h3cPseScalarGroup OBJECT-GROUP
OBJECTS { h3cPseAutoDetectActive, h3cPsePowerMaxValue, h3cPsePolicyMode ,
h3cPDPolicyMode }
STATUS current
DESCRIPTION
"A collection of scalar objects supported."
::= { h3cPseGroup 3 }
h3cPsePDNotificationGroup OBJECT-GROUP
OBJECTS { h3cpsePDChangeNotification }
STATUS current
DESCRIPTION
"PD Change Notification."
::= { h3cPseGroup 4 }
h3cPseProfilesGroup OBJECT-GROUP
OBJECTS { h3cPseProfileName, h3cPseProfilePowerMode,
h3cPseProfilePowerLimit, h3cPseProfilePriority,
h3cPseProfilePairs, h3cPseProfileApplyNum, h3cPseProfileRowStatus}
STATUS current
DESCRIPTION
"A collection of objects should be supported at the same time."
::= { h3cPseGroup 5 }
h3cPOEPowerThresholdLimitGroup OBJECT-GROUP
OBJECTS { h3cPOEThresholdACMimimum, h3cPOEThresholdACMaximum,
h3cPOEThresholdDCMinimum, h3cPOEThresholdDCMaximum }
STATUS current
DESCRIPTION
"Power threshold limits group."
::= { h3cPseGroup 6 }
h3cPOEPowerSupInfoGroup OBJECT-GROUP
OBJECTS { h3cPOEPowerType, h3cPOEPowerModuleNum, h3cPOESupervisionModuleName,
h3cPOESMMajorVersion, h3cPOESMMinorVersion, h3cPOESMFactorName}
STATUS current
DESCRIPTION
"The basic Power information group."
::= { h3cPseGroup 7 }
h3cPOEPowerDCOutStateGroup OBJECT-GROUP
OBJECTS { h3cPOEDCOutStateModuleNum }
STATUS current
DESCRIPTION
"The DC out power state group."
::= { h3cPseGroup 8 }
h3cPOEPowerDCOutInfoGroup OBJECT-GROUP
OBJECTS { h3cPOEDCOutCurNum }
STATUS current
DESCRIPTION
"The power AC input switch information group"
::= { h3cPseGroup 9 }
h3cPOEPowerACSwitchStateModuleGroup OBJECT-GROUP
OBJECTS { h3cPOEACSwitchStateModuleNum}
STATUS current
DESCRIPTION
"PD Change Notification."
::= { h3cPseGroup 10 }
h3cPOEPowerInCurStateGroup OBJECT-GROUP
OBJECTS { h3cPOEInCurStateModuleNum, h3cPOEInCurAState, h3cPOEInCurBState,
h3cPOEInCurCState}
STATUS current
DESCRIPTION
"PD Change Notification."
::= { h3cPseGroup 11 }
h3cPOEPowerAlarmStateGroup OBJECT-GROUP
OBJECTS { h3cPOEAlarmStateModuleNum }
STATUS current
DESCRIPTION
"PD Change Notification."
::= { h3cPseGroup 12 }
ACAlarmState ::= INTEGER {
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)
}
DCAlarmState ::= INTEGER {
normal (1),
underLimit (2),
aboveLimit (3),
fuseBroken (4),
switchOff (5),
otherError (6)
}
SwitchState ::= INTEGER {
on (1),
off (2),
highVoltInput (3),
lowVoltInput (4)
}
ModuleAlarmState ::= INTEGER {
normal (1),
alarm (2)
}
h3cPOEPowerObjects OBJECT IDENTIFIER ::= { h3cPowerEthernetExt 8 }
h3cPOEThresholdLimitObjs OBJECT IDENTIFIER ::= { h3cPOEPowerObjects 1 }
h3cPOEThresholdACMimimum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input threshold AC minimum.
It is a read-write node.
The value of this node is 'OCTET STRING',
it is used to describe a float value.
So this string should fit the following rule:
1. This string should be terminated by '\0';
2. Every characters should be number or radix point;
3. The radix point should occur only once, and it should not
be the first or the last character of the string.
The value of this node should be smaller than 264.0V and larger than 90.0V.
And it should be smaller than the h3cPOEThresholdACMaximum."
::= { h3cPOEThresholdLimitObjs 1 }
h3cPOEThresholdACMaximum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input threshold AC maximum.
It is a read-write node.
The value of this node is 'OCTET STRING',
it is used to describe a float value.
So this string should fit the following rule:
1. This string should be terminated by '\0';
2. Every characters should be number or radix point;
3. The radix point should occur only once, and it should not
be the first or the last character of the string.
It should be smaller than 264.0V and larger than 90.0V.
And it should be larger than the h3cPOEThresholdACMinimum."
::= { h3cPOEThresholdLimitObjs 2 }
h3cPOEThresholdDCMinimum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input threshold DC minimum.
It is a read-write node.
The value of this node is 'OCTET STRING',
it is used to describe a float value.
So this string should fit the following rule:
1. This string should be terminated by '\0';
2. Every characters should be number or radix point;
3. The radix point should occur only once, and it should not
be the first or the last character of the string.
It should be smaller than 47.0V and larger than 45.0V."
::= { h3cPOEThresholdLimitObjs 3 }
h3cPOEThresholdDCMaximum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input threshold DC maximum.
It is a read-write node.
The value of this node is 'OCTET STRING',
it is used to describe a float value.
So this string should fit the following rule:
1. This string should be terminated by '\0';
2. Every characters should be number or radix point;
3. The radix point should occur only once, and it should not
be the first or the last character of the string.
It should be smaller than 57.0V and larger than 55.0V."
::= { h3cPOEThresholdLimitObjs 4 }
h3cPOESupModuleInfoObjs OBJECT IDENTIFIER ::= { h3cPOEPowerObjects 2 }
h3cPOEPowerType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the power."
::= { h3cPOESupModuleInfoObjs 1 }
h3cPOEPowerModuleNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the power modules."
::= { h3cPOESupModuleInfoObjs 2 }
h3cPOESupervisionModuleName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the Supervision Module name on this POE power."
::= { h3cPOESupModuleInfoObjs 3 }
h3cPOESMMajorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the high byte of the monitor module version."
::= { h3cPOESupModuleInfoObjs 4 }
h3cPOESMMinorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the low byte of the monitor module version."
::= { h3cPOESupModuleInfoObjs 5 }
h3cPOESMFactorName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the name of the manufactor."
::= { h3cPOESupModuleInfoObjs 6 }
h3cPOEModuleInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPOEModuleInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of the module information on this POE power."
::= { h3cPOESupModuleInfoObjs 7 }
h3cPOEModuleInfoEntry OBJECT-TYPE
SYNTAX H3cPOEModuleInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the module information on this POE power."
INDEX { h3cPOEModuleIndex }
::= { h3cPOEModuleInfoTable 1 }
H3cPOEModuleInfoEntry ::=
SEQUENCE {
h3cPOEModuleIndex
Integer32,
h3cPOEModuleID
Integer32,
h3cPOEModuleInfoPower
Integer32,
h3cPOEModuleHardVerInfo
OCTET STRING
}
h3cPOEModuleIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of the current module on this POE power.
It is also the index of h3cPOEModuleInfoTable.
The range of this node is from 1 to h3cPOEPowerModuleNum."
::= { h3cPOEModuleInfoEntry 1 }
h3cPOEModuleID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of the current module on this POE power."
::= { h3cPOEModuleInfoEntry 2 }
h3cPOEModuleInfoPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power of the current module on this POE power."
::= { h3cPOEModuleInfoEntry 3 }
h3cPOEModuleHardVerInfo OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hardware version information of the current module on this POE power."
::= { h3cPOEModuleInfoEntry 4 }
h3cPOEDCOutStateObjects OBJECT IDENTIFIER ::= { h3cPOEPowerObjects 3 }
h3cPOEDCOutStateModuleNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module number on this POE power.
It is the maximum of the h3cPOEDCOutStateIndex."
::= { h3cPOEDCOutStateObjects 1 }
h3cPOEDCOutStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPOEDCOutStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of DC output power state on this POE power."
::= { h3cPOEDCOutStateObjects 2 }
h3cPOEDCOutStateEntry OBJECT-TYPE
SYNTAX H3cPOEDCOutStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the DC output power state on this POE power."
INDEX { h3cPOEDCOutStateIndex }
::= { h3cPOEDCOutStateTable 1 }
H3cPOEDCOutStateEntry ::=
SEQUENCE {
h3cPOEDCOutStateIndex
Integer32,
h3cPOEDCOutDCVolAlarm
DCAlarmState
}
h3cPOEDCOutStateIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of the DC output power state on this POE power.
The range of this node is from 1 to h3cPOEDCOutStateModuleNum."
::= { h3cPOEDCOutStateEntry 1 }
h3cPOEDCOutDCVolAlarm OBJECT-TYPE
SYNTAX DCAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DC output alarm of the DC output power state on this POE power.
The value of this node will be the following values:
normal (1),
underLimit (2),
aboveLimit (3),
fuseBroken (4),
switchOff (5),
otherError (6)."
::= { h3cPOEDCOutStateEntry 2 }
h3cPOEDCOutInfoObjects OBJECT IDENTIFIER ::= { h3cPOEPowerObjects 4 }
h3cPOEDCOutCurNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DC output current on this POE power.
It is the maximum of h3cPOEDCOutInfoIndex."
::= { h3cPOEDCOutInfoObjects 1 }
h3cPOEDCOutInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPOEDCOutInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of the DC output information on this POE power."
::= { h3cPOEDCOutInfoObjects 2 }
h3cPOEDCOutInfoEntry OBJECT-TYPE
SYNTAX H3cPOEDCOutInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the DC output information on this POE power."
INDEX { h3cPOEDCOutInfoIndex }
::= { h3cPOEDCOutInfoTable 1 }
H3cPOEDCOutInfoEntry ::=
SEQUENCE {
h3cPOEDCOutInfoIndex
Integer32,
h3cPOEDCOutVol
OCTET STRING,
h3cPOEDCOutInfoLoadCur
OCTET STRING
}
h3cPOEDCOutInfoIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of the DC output information on this POE POWER.
The range of this node is from 1 to h3cPOEDCOutCurNum."
::= { h3cPOEDCOutInfoEntry 1 }
h3cPOEDCOutVol OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DC output voltage of the current DC output on this POE power."
::= { h3cPOEDCOutInfoEntry 2 }
h3cPOEDCOutInfoLoadCur OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total load current of the current DC output on this POE power."
::= { h3cPOEDCOutInfoEntry 3 }
h3cPOEACSwitchStateModuleObjs OBJECT IDENTIFIER ::= { h3cPOEPowerObjects 5 }
h3cPOEACSwitchStateModuleNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the AC swtich state module on this POE power.
It is the maximum of h3cPOEACSwitchStateIndex."
::= { h3cPOEACSwitchStateModuleObjs 1 }
h3cPOEACSwitchStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPOEACSwitchStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of the AC switch state on this POE power."
::= { h3cPOEACSwitchStateModuleObjs 2 }
h3cPOEACSwitchStateEntry OBJECT-TYPE
SYNTAX H3cPOEACSwitchStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the AC switch state on this POE power."
INDEX { h3cPOEACSwitchStateIndex }
::= { h3cPOEACSwitchStateTable 1 }
H3cPOEACSwitchStateEntry ::=
SEQUENCE {
h3cPOEACSwitchStateIndex
Integer32,
h3cPOEACSwitchState
SwitchState
}
h3cPOEACSwitchStateIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of the AC switch state on this POE power.
The range of this node is from 1 to h3cPOEACSwitchStateModuleNum."
::= { h3cPOEACSwitchStateEntry 1 }
h3cPOEACSwitchState OBJECT-TYPE
SYNTAX SwitchState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The AC switch state on this POE power.
The value of this node will be one of the following values:
on (1),
off (2),
highVoltInput (3),
lowVoltInput (4)"
::= { h3cPOEACSwitchStateEntry 2 }
h3cPOEInCurStateObjects OBJECT IDENTIFIER ::= { h3cPOEPowerObjects 6 }
h3cPOEInCurStateModuleNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DC input current state of the module on this POE power.
It is the maximum of the h3cPOESwitchStateVolExIndex."
::= { h3cPOEInCurStateObjects 1 }
h3cPOEInCurAState OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current A state in the DC input on this POE power.
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { h3cPOEInCurStateObjects 2 }
h3cPOEInCurBState OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current B state in the DC input on this POE power.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { h3cPOEInCurStateObjects 3 }
h3cPOEInCurCState OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current C state in the DC input on this POE power.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { h3cPOEInCurStateObjects 4 }
h3cPOESwitchStateVolExTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPOESwitchStateVolExEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All alarm status of the VOL status.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { h3cPOEInCurStateObjects 5 }
h3cPOESwitchStateVolExEntry OBJECT-TYPE
SYNTAX H3cPOESwitchStateVolExEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The h3cPOESwitchStateVolExIndex will match the number of the VOL status."
INDEX { h3cPOESwitchStateVolExIndex }
::= { h3cPOESwitchStateVolExTable 1 }
H3cPOESwitchStateVolExEntry ::=
SEQUENCE {
h3cPOESwitchStateVolExIndex
Integer32,
h3cPOESwitchStateInVolAB
ACAlarmState,
h3cPOESwitchStateInVolBC
ACAlarmState,
h3cPOESwitchStateInVolCA
ACAlarmState
}
h3cPOESwitchStateVolExIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The object species the index of the VOL status.
The range of this node is from 1 to h3cPOEInCurStateModuleNum."
::= { h3cPOESwitchStateVolExEntry 1 }
h3cPOESwitchStateInVolAB OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the VOL AB alarm in each VOL status.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { h3cPOESwitchStateVolExEntry 2 }
h3cPOESwitchStateInVolBC OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the VOL BC alarm in each VOL status.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { h3cPOESwitchStateVolExEntry 3 }
h3cPOESwitchStateInVolCA OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the VOL CA alarm in each VOL status.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { h3cPOESwitchStateVolExEntry 4 }
h3cPOEAlarmStateObjects OBJECT IDENTIFIER ::= { h3cPOEPowerObjects 7 }
h3cPOEAlarmStateModuleNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the number of the power modules in alarm state."
::= { h3cPOEAlarmStateObjects 1 }
h3cPOEAlarmStateInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cPOEAlarmStateInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All alarm states in the POE power modules."
::= { h3cPOEAlarmStateObjects 2 }
h3cPOEAlarmStateInfoEntry OBJECT-TYPE
SYNTAX H3cPOEAlarmStateInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The h3cPOEAlarmModuleInfoIndex will match the number
of the power module."
INDEX { h3cPOEAlarmModuleInfoIndex }
::= { h3cPOEAlarmStateInfoTable 1 }
H3cPOEAlarmStateInfoEntry ::=
SEQUENCE {
h3cPOEAlarmModuleInfoIndex
Integer32,
h3cPOEModuleDisconnect
ModuleAlarmState,
h3cPOEModuleInputError
ModuleAlarmState,
h3cPOEModuleOutputError
ModuleAlarmState,
h3cPOEModuleOverVoltage
ModuleAlarmState,
h3cPOEModuleOverTemp
ModuleAlarmState,
h3cPOEModuleFanError
ModuleAlarmState,
h3cPOEModuleShutdown
ModuleAlarmState,
h3cPOEModuleCurRestricted
ModuleAlarmState
}
h3cPOEAlarmModuleInfoIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index specifies the index of the H3cPOEAlarmStateInfoEntry table.
The range of this node is from 1 to h3cPOEAlarmStateModuleNum."
::= { h3cPOEAlarmStateInfoEntry 1 }
h3cPOEModuleDisconnect OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The module does not link.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { h3cPOEAlarmStateInfoEntry 2 }
h3cPOEModuleInputError OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
Input error.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { h3cPOEAlarmStateInfoEntry 3 }
h3cPOEModuleOutputError OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
Output error.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { h3cPOEAlarmStateInfoEntry 4 }
h3cPOEModuleOverVoltage OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The voltage is too high.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { h3cPOEAlarmStateInfoEntry 5 }
h3cPOEModuleOverTemp OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The temperature is too high.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { h3cPOEAlarmStateInfoEntry 6 }
h3cPOEModuleFanError OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The fan error.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { h3cPOEAlarmStateInfoEntry 7 }
h3cPOEModuleShutdown OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The module is shutdown.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { h3cPOEAlarmStateInfoEntry 8 }
h3cPOEModuleCurRestricted OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The module limit the current.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { h3cPOEAlarmStateInfoEntry 9 }
END