NSCRTV-HFCEMS-ANALOG-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
enterprises
|
||
FROM RFC1155-SMI
|
||
DisplayString
|
||
FROM SNMPv2-TC ;
|
||
nscrtvRoot OBJECT IDENTIFIER ::= { enterprises 17409 }
|
||
|
||
-- DESCRIPTION
|
||
-- "NscrtvRoot definition of the National Radio and Television Standardization Technical Committee MIB root nodes"
|
||
|
||
nscrtvHFCemsTree OBJECT IDENTIFIER ::= { nscrtvRoot 1 }
|
||
|
||
-- DESCRIPTION
|
||
-- "NscrtvHFCemsTree definition HFC network equipment management system MIB root nodes,"
|
||
-- "All HFC network equipment management system should be in the MIB definition of nodes"
|
||
|
||
propertyIdent OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 1}
|
||
|
||
-- DESCRIPTION
|
||
-- "Attribute (Property) MIB branch nodes logo"
|
||
-- "See Appendix C"
|
||
|
||
alarmsIdent OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 2}
|
||
|
||
-- DESCRIPTION
|
||
-- "¸æ¾¯(Alarms)MIBµÄ·ÖÖ§½Úµã±êʶ Alarms MIB branch nodes logo"
|
||
-- "See Appendix D"
|
||
|
||
commonIdent OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 3}
|
||
|
||
-- DESCRIPTION
|
||
-- "Utility (Common) MIB branch nodes logo"
|
||
-- "See Appendix E"
|
||
|
||
oswIdent OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 15}
|
||
|
||
-- DESCRIPTION
|
||
-- "Optical switch MIB branch node identifier."
|
||
|
||
--**********************************************************************************************
|
||
-- analog MIB
|
||
--**********************************************************************************************
|
||
analogPropertyTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AnalogPropertyEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Simulation parameters attribute table."
|
||
::= { propertyIdent 1 }
|
||
|
||
analogPropertyEntry OBJECT-TYPE
|
||
SYNTAX AnalogPropertyEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Attribute Table simulation parameters head.OID purpose as a table index, the coding method is 'length + OID.' OID before two members of the '130' is based on '1' and '3' respectively coding, and not ordinary OID encoding (0x2B)."
|
||
INDEX { analogParameterOID }
|
||
::= { analogPropertyTable 1 }
|
||
|
||
AnalogPropertyEntry ::= SEQUENCE {
|
||
analogParameterOID
|
||
OBJECT IDENTIFIER,
|
||
alarmEnable
|
||
OCTET STRING,
|
||
analogAlarmState
|
||
INTEGER,
|
||
analogAlarmHIHI
|
||
INTEGER,
|
||
analogAlarmHI
|
||
INTEGER,
|
||
analogAlarmLO
|
||
INTEGER,
|
||
analogAlarmLOLO
|
||
INTEGER,
|
||
analogAlarmDeadband
|
||
INTEGER
|
||
}
|
||
|
||
analogParameterOID OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"index"
|
||
|
||
::= { analogPropertyEntry 1 }
|
||
|
||
alarmEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm enable control byte, the corresponding position for the'1 'that allow alarm,'0' a ban warning
|
||
Bit 0: Alarm enable low
|
||
Bit 1: Alarm enable low
|
||
Bit 2: Alarm enable high
|
||
Bit 3: Alarm enable high
|
||
Bit 4 ~ 7 reservations should be 0
|
||
This object should be stored in nonvolatile memory."
|
||
|
||
::= { analogPropertyEntry 2 }
|
||
|
||
analogAlarmState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
aasNominal (1),
|
||
aasHIHI (2),
|
||
aasHI (3),
|
||
aasLO (4),
|
||
aasLOLO (5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The parameters of the current state of alarm."
|
||
::= { analogPropertyEntry 3 }
|
||
|
||
analogAlarmHIHI OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The parameters of the current state of alarm."
|
||
::= { analogPropertyEntry 4 }
|
||
|
||
analogAlarmHI OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"HI high alarm threshold value. This object should be stored in non-volatile memory"
|
||
::= { analogPropertyEntry 5 }
|
||
|
||
analogAlarmLO OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"LO low alarm threshold value. This object should be stored in nonvolatile memory"
|
||
::= { analogPropertyEntry 6 }
|
||
|
||
analogAlarmLOLO OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm LOLO very low threshold value. This object should be stored in nonvolatile memory."
|
||
::= { analogPropertyEntry 7 }
|
||
|
||
analogAlarmDeadband OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Dead-alarm threshold value. After the warning, parameter values should be restored to the alarm threshold and alarm threshold and the difference between the absolute value greater than the value of dead zone, the alarm can be removed.This object should be stored in nonvolatile memory."
|
||
::= { analogPropertyEntry 8 }
|
||
|
||
-- *
|
||
-- * ÀëÉ¢ÊôÐÔ±í
|
||
-- * ÀëÉ¢ÊôÐÔ±íµÄ¼Ç¼ÊýÁ¿Êǹ̶¨µÄ£¬Ã¿¸öÀëÉ¢ÐͲÎÊýµÄÿһ¸öÐèÒª½øÐи澯´¦ÀíµÄÖµÔÚ±í
|
||
-- * Öоù¶ÔÓ¦Ò»Ìõ¼Ç¼¡£Ã¿¸öÀëÉ¢ÐͲÎÊýÔÚÀëÉ¢ÊôÐÔ±íÖÐÖÁÉÙ¶ÔÓ¦ÓÐÒ»Ìõ¼Ç¼¡£
|
||
-- * ÀëÉ¢ÊôÐÔ±íÓÐ2¸öË÷Òý£ºÒ»¸öÊDzÎÊý±êʶ£¨OID£©£¬ÁíÒ»¸öÊÇÀëÉ¢¸æ¾¯Öµ£¨discreteAlarmValue£©¡£
|
||
-- *
|
||
|
||
discretePropertyTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DiscretePropertyEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Discrete Attribute Table"
|
||
::= { propertyIdent 2 }
|
||
|
||
discretePropertyEntry OBJECT-TYPE
|
||
SYNTAX DiscretePropertyEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Attribute Table discrete head. OID coding methods with simulation attribute table."
|
||
INDEX { discreteParameterOID, discreteAlarmValue }
|
||
::= { discretePropertyTable 1 }
|
||
|
||
DiscretePropertyEntry ::= SEQUENCE {
|
||
discreteParameterOID
|
||
OBJECT IDENTIFIER,
|
||
discreteAlarmValue
|
||
INTEGER,
|
||
discreteAlarmEnable
|
||
INTEGER,
|
||
discreteAlarmState
|
||
INTEGER
|
||
}
|
||
|
||
discreteParameterOID OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Attribute Table discrete index 1: Parameters OID"
|
||
::= { discretePropertyEntry 1 }
|
||
|
||
discreteAlarmValue OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Attribute Table discrete index 2: parameter values.When the equipment value of this parameter values, and so will be dealt with a warning"
|
||
::= { discretePropertyEntry 2 }
|
||
|
||
|
||
discreteAlarmEnable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disable (1),
|
||
enableMajor (2),
|
||
enableMinor (3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When the alarm so that it can open the (2 or 3), this parameter allows for alarm processin
|
||
If the alarm so that it can shut down (1), alarm processing will be carried out.
|
||
This object default values for the disable (1).
|
||
This object should be stored in non-volatile memory"
|
||
::= { discretePropertyEntry 3 }
|
||
|
||
discreteAlarmState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
dasNominal(1),
|
||
dasDiscreteMajor(6),
|
||
dasDiscreteMinor(7)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The parameters of the current state of alarm"
|
||
::= { discretePropertyEntry 4 }
|
||
|
||
|
||
|
||
currentAlarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CurrentAlarmEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The current alarm table."
|
||
::= { propertyIdent 3 }
|
||
|
||
currentAlarmEntry OBJECT-TYPE
|
||
SYNTAX CurrentAlarmEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The current warning Table Head. OID coding methods with simulation attribute table"
|
||
INDEX { currentAlarmOID }
|
||
::= { currentAlarmTable 1 }
|
||
|
||
CurrentAlarmEntry ::= SEQUENCE {
|
||
currentAlarmOID
|
||
OBJECT IDENTIFIER,
|
||
currentAlarmState
|
||
INTEGER,
|
||
currentAlarmValue
|
||
INTEGER
|
||
|
||
}
|
||
|
||
currentAlarmOID OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"NE, currently in a state of alarm parameters OID Index, and the alarm in the table attribute parameters OID counterparts."
|
||
::= { currentAlarmEntry 1 }
|
||
|
||
currentAlarmState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
caasHIHI (2),
|
||
caasHI (3),
|
||
caasLO (4),
|
||
caasLOLO (5),
|
||
caasDiscreteMajor (6),
|
||
caasDiscreteMinor (7)
|
||
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Warning parameters of the current state of alarm"
|
||
::= { currentAlarmEntry 2 }
|
||
|
||
currentAlarmValue OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm parameter values."
|
||
::= { currentAlarmEntry 3 }
|
||
|
||
--************************************************************************************************
|
||
-- alarm MIB
|
||
--************************************************************************************************
|
||
alarmLogNumberOfEntries OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm record number of records in the table"
|
||
::= { alarmsIdent 1 }
|
||
|
||
alarmLogLastIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Recently a warning the index of the records."
|
||
::= { alarmsIdent 2 }
|
||
|
||
alarmLogTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AlarmLogEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm record form, at least support 16 record. Each table in the registration of a new record, the management agent (transponder) managers should send traps news"
|
||
::= { alarmsIdent 3 }
|
||
|
||
alarmLogEntry OBJECT-TYPE
|
||
SYNTAX AlarmLogEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm Sheet Head"
|
||
INDEX { alarmLogIndex }
|
||
::= { alarmLogTable 1 }
|
||
|
||
AlarmLogEntry ::=
|
||
SEQUENCE
|
||
{
|
||
alarmLogIndex
|
||
INTEGER,
|
||
alarmLogInformation
|
||
OCTET STRING
|
||
}
|
||
|
||
alarmLogIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..32767)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The only logo Alarm Index recorded a record in the table, the index value increased from 1 start of each new record, plus 1 until 32767, under a record index of the re-starts at 1. Acting under the management of storage capacity can be the first choice to delete those records, the specific details in this not to achieve requirements."
|
||
::= { alarmLogEntry 1 }
|
||
|
||
alarmLogInformation OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 17..255 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm record information, multi-byte strings, defined as follows:
|
||
Byte 1 ~ 4: Alarm in time (POSIX format, the previous maximum byte)
|
||
Byte 5: Alarm types (enumeration, definitions¼ûºó)
|
||
Byte 6: Alarm value after commonNeStatus
|
||
Byte 7 ~ m: Alarm parameters object identifier (Basic Encoding Rules (ASN.1))
|
||
Byte n ~ z: Alarm parameter values (Basic Encoding Rules (ASN.1))
|
||
Alarm enumerated types:
|
||
1 NOMINAL
|
||
2 HIHI
|
||
3 HI
|
||
4 LO
|
||
5 LOLO
|
||
6 Discrete Major
|
||
7 Discrete Minor"
|
||
::= { alarmLogEntry 2 }
|
||
|
||
alarmText OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This trap targets for the needs of information contained in a text field transponder information is achievable.The field contains the text of the object depends on the definition of alarm parameters, it is uncertain, Provisions of this object can not access."
|
||
|
||
::= { alarmsIdent 4 }
|
||
|
||
hfcAlarmEvent TRAP-TYPE
|
||
ENTERPRISE nscrtvHFCemsTree
|
||
VARIABLES { commonPhysAddress, commonNELogicalID, alarmLogInformation, alarmText }
|
||
DESCRIPTION
|
||
"When detected in the event of alarm information sent this trap, whether bundled alarmText variable parameter under warning object to determine. Some of the parameters only need to bind the alarm first three variables"
|
||
::= 1
|
||
|
||
--***********************************************************************************************
|
||
-- common MIB
|
||
--**********************************************************************************************
|
||
-- *
|
||
-- * Common MIB
|
||
-- *
|
||
commonAdminGroup OBJECT IDENTIFIER ::= { commonIdent 1 }
|
||
commonAdminUseRf OBJECT IDENTIFIER ::= { commonIdent 2 }
|
||
commonAdminUseEthernet OBJECT IDENTIFIER ::= { commonIdent 3 }
|
||
|
||
commonMACGroup OBJECT IDENTIFIER ::= { commonAdminUseRf 1 }
|
||
commonRfGroup OBJECT IDENTIFIER ::= { commonAdminUseRf 2 }
|
||
|
||
commonMacAddress OBJECT IDENTIFIER ::= { commonMACGroup 1 }
|
||
commonBackoffParams OBJECT IDENTIFIER ::= { commonMACGroup 2 }
|
||
commonMacStats OBJECT IDENTIFIER ::= { commonMACGroup 3 }
|
||
|
||
commonAgentGroup OBJECT IDENTIFIER ::= { commonAdminUseEthernet 1 }
|
||
commonDeviceGroup OBJECT IDENTIFIER ::= { commonAdminUseEthernet 2 }
|
||
|
||
-- *************
|
||
-- * NE
|
||
-- *************
|
||
|
||
commonNELogicalID OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..40))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The logic of the designated NE identifier (LogicID), the values and attributes of other unrelated NE.This target value should be stored in non-volatile memory"
|
||
::= { commonAdminGroup 1 }
|
||
|
||
commonNEVendor OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"NE equipment manufacturers¡£"
|
||
::= { commonAdminGroup 2 }
|
||
|
||
commonNEModelNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
""
|
||
::= { commonAdminGroup 3 }
|
||
|
||
commonNESerialNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"NE equipment serial numbers"
|
||
::= { commonAdminGroup 4 }
|
||
|
||
commonNEVendorInfo OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"NE equipment suppliers other special designated information"
|
||
::= { commonAdminGroup 5 }
|
||
|
||
commonNEStatus OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"With 7.5.4 STATRESP PDU in the corresponding parameters Status
|
||
Bit 0: CHNLRQST
|
||
Bit 1: CNTNRM
|
||
Bit 2: CNTCUR
|
||
Bit 3: MAJOR ALARMS
|
||
Bit 4: MINOR ALARMS
|
||
Bit 5: RSVD1
|
||
Bit 6: RSVD2
|
||
Bit 7: RSVD3"
|
||
::= { commonAdminGroup 6 }
|
||
|
||
commonReset OBJECT-TYPE
|
||
SYNTAX INTEGER { reset (1) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Write'1 'will be reset NE equipment, the value will be included in other non-functional. Reading this object return value'1 ', the equipment had no effect¡£"
|
||
::= { commonAdminGroup 7 }
|
||
|
||
commonAlarmDetectionControl OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
detectionDisabled (1),
|
||
detectionEnabled (2),
|
||
detectionEnabledAndRegenerate (3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This object used to control the Alarm Detection NE.When the attribute table or discrete simulation attribute table MIB objects to a set threshold, that alarm has occurred and, as recorded in the latest warning alarm Sheet (alarmLogTable) add one warning traps will also produce.
|
||
If the value of a MIB object is not normal, and the current alarm in the table (currentAlarmTable) will also add a record.DetectionDisabled (1) will stop and simulation Attribute Table / Attribute Table associated discrete alarm detection process, NE will no longer have a warning.
|
||
DetectionEnabled (2) allow the alarm detection, detection from detectionEnabled be set in which the transponder before beginning continue. DetectionEnabledAndRegenerate (3) removal of all information and allow Warning Alarm Detection conducted.
|
||
Attribute Table and discrete simulation attribute table of all alarm attributes will be returned to the alarm before the normal operation of the.
|
||
Any still in a state of alarm attributes will not have a 'return to normal' warning, set this value will remove warning and the current record sheet alarmLogTable Alarm Table currentAlarmTable content.
|
||
DetectionEnabledAndRegenerate role is temporary, as will be set to detectionEnabledAndRegnerate commonAlarmDetectionControl after its SNMP response includes this value, if read beyond this target value, the response to detectionEnabled.DetectionDisabled hfcColdStart or value does not affect the selection of hfcWarmStart traps.Future additional traps in its description unless there are specific provisions in Otherwise they would be free from the impact of this object.
|
||
This object should be stored in nonvolatile memory, the default values for detectionEnabled"
|
||
::= { commonAdminGroup 8 }
|
||
|
||
commonNetworkAddress OBJECT-TYPE
|
||
SYNTAX NetworkAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"NE network IP address, NE produce Trap should include this address. This value should be stored in nonvolatile memory. This value can be registered through the MAC order or through the local interface vendors to set up."
|
||
::= { commonAdminGroup 9 }
|
||
|
||
|
||
commonCheckCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This target for the detection transponder code configuration of the report. The calculation includes detection code transponder (including management equipment) and the physical configuration parameters stored in non-volatile memory of all the parameters. The detection algorithm calculated by the vendor code provisions.
|
||
The object should be kept in the value of non-volatile memory, the response thinks highly activated, will be recalculated and re-testing code and the value prior to the commencement of comparison to determine whether or should haveÒ»¸öhfcColdStart hfcWarmStart traps.
|
||
When write this object (SetRequest), the detection code will be recalculated and fill the SetRequest in response to the GetResponse. At this time, will not produce hfcColdStart or hfcWarmStart traps."
|
||
::= { commonAdminGroup 10 }
|
||
|
||
commonTrapCommunityString OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..64))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Definition of Community Trap string. The default value is' public '"
|
||
::= { commonAdminGroup 11 }
|
||
|
||
commonTamperStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { intact (1), compromised (2) }
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The safety report NE switching equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, compromised expressed alarm"
|
||
::= { commonAdminGroup 12 }
|
||
|
||
commonInternalTemperature OBJECT-TYPE
|
||
SYNTAX INTEGER (-128..127)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"NE equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table"
|
||
::= { commonAdminGroup 13 }
|
||
|
||
commonTime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"NE of the POSIX said that the current time (since at 0:00 on January 1, 1970 since the seconds)."
|
||
::= { commonAdminGroup 14 }
|
||
|
||
commonVarBindings OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This object can be said to receive SNMP information NE variables bundled the largest number of tables. Value: 0 indicated no restrictions on the maximum number bundled"
|
||
::= { commonAdminGroup 15 }
|
||
|
||
commonResetCause OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other (1),
|
||
powerup (2),
|
||
command (3),
|
||
watchdog (4),
|
||
craft (5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"NE said the reasons for the recent reduction."
|
||
::= { commonAdminGroup 16 }
|
||
|
||
commonCraftStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disconnected (1),
|
||
connected (2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"NE local object that this interface (such as RS232 or RS485 interface) state. NE does not necessarily have to support the local interface. NE local interface without affecting the state of its MAC interface functions; If we do not support the local interface, and its value is disconnected."
|
||
::= { commonAdminGroup 17 }
|
||
|
||
commonDeviceOID OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This OID object as a pointer, the equipment was used at MIB (such as Node, two-way amplifier, etc.). "
|
||
::= { commonAdminGroup 18 }
|
||
|
||
commonDeviceId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(32))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The contents of this object by the designated by the equipment vendors, manufacturers and products it contains special ASCII text messages"
|
||
::= { commonAdminGroup 19 }
|
||
|
||
|
||
|
||
-- ****************
|
||
-- * NE PhysAddress
|
||
-- ****************
|
||
|
||
commonPhysAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"NE physical address"
|
||
::= { commonMacAddress 1 }
|
||
|
||
commonMaxMulticastAddresses OBJECT-TYPE
|
||
SYNTAX INTEGER (4..255)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"NE equipment to support the greatest number of multicast addresses."
|
||
::= { commonMacAddress 2 }
|
||
|
||
commonMulticastAddressTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CommonMulticastAddressEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Multicast addresses Table, the value of this object should be stored in nonvolatile memory."
|
||
::= { commonMacAddress 3 }
|
||
|
||
commonMulticastAddressEntry OBJECT-TYPE
|
||
SYNTAX CommonMulticastAddressEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Multicast addresses head table."
|
||
INDEX { commonMulticastAddressIndex }
|
||
::= { commonMulticastAddressTable 1 }
|
||
|
||
CommonMulticastAddressEntry ::=
|
||
SEQUENCE
|
||
{
|
||
commonMulticastAddressIndex
|
||
INTEGER,
|
||
commonMulticastAddressNumber
|
||
OCTET STRING
|
||
}
|
||
|
||
commonMulticastAddressIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..255)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Multicast addresses head table."
|
||
::= { commonMulticastAddressEntry 1 }
|
||
|
||
commonMulticastAddressNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(6))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Multicast address, I / G-1 effective."
|
||
::= { commonMulticastAddressEntry 2 }
|
||
|
||
|
||
commonBackoffPeriod OBJECT-TYPE
|
||
SYNTAX INTEGER (0..16383)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Backoff algorithm benchmark time (ms), initialize the default value of 6 ms.The value of this object should be stored in nonvolatile memory."
|
||
::= { commonBackoffParams 1 }
|
||
|
||
commonACKTimeoutWindow OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"NE awaiting HE overtime to send ACK response time (ms), initialize the default value is 19 ms.The value of this object should be stored in nonvolatile memory."
|
||
::= { commonBackoffParams 2 }
|
||
|
||
commonMaximumMACLayerRetries OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"NE data packets sent the greatest number of re-examination. Initialize the default value is 16.The value of this object should be stored in nonvolatile memory."
|
||
::= { commonBackoffParams 3 }
|
||
|
||
commonMaxPayloadSize OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"From top to bottom line channel packet supported by the largest payload (payload) the length of"
|
||
::= { commonBackoffParams 4 }
|
||
|
||
commonBackoffMinimumExponent OBJECT-TYPE
|
||
SYNTAX INTEGER (0..15)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The standards body of the MAC layer specification definition of the smallest backoff algorithm index value, default values for 6.This value may not exceed commonBackoffMaximumValue value.The value of this object should be stored in nonvolatile memory."
|
||
::= { commonBackoffParams 5 }
|
||
|
||
commonBackoffMaximumExponent OBJECT-TYPE
|
||
SYNTAX INTEGER (0..15)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The body of the MAC layer standard definition of backoff algorithm for standardizing the largest index value, the default value is 15.This value shall be not less than commonBackoffMinimum value.The value of this object should be stored in nonvolatile memory."
|
||
::= { commonBackoffParams 6 }
|
||
|
||
|
||
commonForwardPathLOSEvents OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"LOS downlink channel in the number of reset to 0."
|
||
::= { commonMacStats 1 }
|
||
|
||
commonForwardPathFramingErrors OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Downlink Channel frames wrong number reset to 0."
|
||
::= { commonMacStats 2 }
|
||
|
||
commonForwardPathCRCErrors OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"CRC errors down the number of reset to 0."
|
||
::= { commonMacStats 3 }
|
||
|
||
commonInvalidMacCmds OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Invalid MAC layer order wrong number reset to 0."
|
||
::= { commonMacStats 4 }
|
||
|
||
commonBackwardPathCollisionTimes OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Uplink Packet collision frequency, reset to 0."
|
||
::= { commonMacStats 5 }
|
||
|
||
|
||
|
||
commonReturnPathFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1000000000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Channel uplink frequency units Hz.The value of this object should be stored in non-volatile memory"
|
||
::= { commonRfGroup 1 }
|
||
|
||
commonForwardPathFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1000000000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Downlink frequency channel, flat Hz.The value of this object should be stored in nonvolatile memory."
|
||
::= { commonRfGroup 2 }
|
||
|
||
commonProvisionedReturnPowerLevel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..127)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Upstream channel power levels and units for dBuV.When the internal use of this value will be rounded to the nearest support value. Reading return to this subject when the actual value rather than rounding value.The value of this object should be stored in nonvolatile memory."
|
||
::= { commonRfGroup 3 }
|
||
|
||
commonForwardPathReceiveLevel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..127)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Downlink Channel receive power levels, units dBuV."
|
||
::= { commonRfGroup 4 }
|
||
|
||
commonMaxReturnPower OBJECT-TYPE
|
||
SYNTAX INTEGER (0..127)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The largest upstream channel power levels and units for dBuV.The value of this object should be stored in nonvolatile memory."
|
||
::= { commonRfGroup 5 }
|
||
|
||
|
||
commonAgentBootWay OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
bootDefault (1),
|
||
bootBOOTP (2),
|
||
bootTFTP (3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
""
|
||
::= { commonAgentGroup 1 }
|
||
|
||
commonAgentReset OBJECT-TYPE
|
||
SYNTAX INTEGER { reset(1) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Acting Restart, write'1 'will enable agents to restart, the value will be included in other non-functional. Reading this object return value'1 ', the agent had no effect"
|
||
::= { commonAgentGroup 2 }
|
||
|
||
commonAgentMaxTraps OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Acting detected alarm when sent to the management of the largest number of TRAP, 0 that manufacturers use the default default values"
|
||
::= { commonAgentGroup 3 }
|
||
|
||
commonAgentTrapMinInterval OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Acting TRAP send the minimum spacing units"
|
||
::= { commonAgentGroup 4 }
|
||
|
||
commonAgentTrapMaxInterval OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Acting TRAP send the largest spacing units for"
|
||
::= { commonAgentGroup 5 }
|
||
|
||
commonTrapAck OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 17..255 ) )
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The variables used to notify Snmp agents, it issued the warning Trap has received information management console, do not have to re-hair. The content of the variables in alarmLogInformation MIB and the same warning. Agents received after the adoption of alarmLogInformation management can clearly know the host response is a warning which Trap information, thereby stop the alarm Trap weight of the information."
|
||
::= { commonAgentGroup 6 }
|
||
|
||
commonAgentTrapTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CommonAgentTrapEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Acting Information Table TRAP"
|
||
::= { commonAgentGroup 7 }
|
||
|
||
commonAgentTrapEntry OBJECT-TYPE
|
||
SYNTAX CommonAgentTrapEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Acting Head TRAP Information Table"
|
||
INDEX { commonAgentTrapIndex }
|
||
::= { commonAgentTrapTable 1 }
|
||
|
||
CommonAgentTrapEntry ::= SEQUENCE {
|
||
commonAgentTrapIndex
|
||
INTEGER,
|
||
commonAgentTrapIP
|
||
IpAddress,
|
||
commonAgentTrapCommunity
|
||
DisplayString,
|
||
commonAgentTrapStatus
|
||
INTEGER
|
||
}
|
||
|
||
commonAgentTrapIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"TRAP Table Index"
|
||
::= { commonAgentTrapEntry 1 }
|
||
|
||
commonAgentTrapIP OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When the purpose of the TRAP host's IP address"
|
||
::= { commonAgentTrapEntry 2 }
|
||
|
||
commonAgentTrapCommunity OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..64))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Send the Community string TRAP"
|
||
::= { commonAgentTrapEntry 3 }
|
||
|
||
commonAgentTrapStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
commonAgentTrapEnable (1),
|
||
commonAgentTrapDisable (2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"It said that the opening of TRAP"
|
||
::= { commonAgentTrapEntry 4 }
|
||
|
||
|
||
commonDeviceNum OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The agent said that the current management is the number of devices"
|
||
::= { commonDeviceGroup 1 }
|
||
|
||
commonDeviceInfoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CommonDeviceInfoEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Acting is currently public information management equipment list."
|
||
::= { commonDeviceGroup 2 }
|
||
|
||
commonDeviceInfoEntry OBJECT-TYPE
|
||
SYNTAX CommonDeviceInfoEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Acting is currently public information management equipment list Table Head."
|
||
INDEX { commonDeviceSlot }
|
||
::= { commonDeviceInfoTable 1 }
|
||
|
||
CommonDeviceInfoEntry ::= SEQUENCE {
|
||
commonDeviceSlot
|
||
INTEGER,
|
||
commonDevicesID
|
||
OCTET STRING,
|
||
commonDeviceVendor
|
||
DisplayString,
|
||
commonDeviceModelNumber
|
||
DisplayString,
|
||
commonDeviceSerialNumber
|
||
DisplayString,
|
||
commonDeviceVendorInfo
|
||
DisplayString,
|
||
commonDeviceStatus
|
||
OCTET STRING,
|
||
commonDeviceReset
|
||
INTEGER,
|
||
commonDeviceAlarmDetectionControl
|
||
INTEGER,
|
||
commonDeviceMACAddress
|
||
NetworkAddress,
|
||
commonDeviceTamperStatus
|
||
INTEGER,
|
||
commonDeviceInternalTemperature
|
||
INTEGER,
|
||
commonDeviceResetCause
|
||
INTEGER,
|
||
commonDeviceCraftStatus
|
||
INTEGER,
|
||
commonDevicesOID
|
||
OBJECT IDENTIFIER,
|
||
commonDeviceAcct
|
||
Counter,
|
||
commonDeviceName
|
||
DisplayString,
|
||
commonDeviceMFD
|
||
DisplayString,
|
||
commonDeviceFW
|
||
DisplayString
|
||
}
|
||
|
||
commonDeviceSlot OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Acting is currently under the management of the equipment list of public information table index."
|
||
::= { commonDeviceInfoEntry 1 }
|
||
|
||
commonDevicesID OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..40))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Designated equipment manufacturers logo"
|
||
::= { commonDeviceInfoEntry 2 }
|
||
|
||
commonDeviceVendor OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Equipment manufacturers"
|
||
::= { commonDeviceInfoEntry 3 }
|
||
|
||
commonDeviceModelNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Equipment models."
|
||
|
||
::= { commonDeviceInfoEntry 4 }
|
||
|
||
commonDeviceSerialNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The string of equipment."
|
||
::= { commonDeviceInfoEntry 5 }
|
||
|
||
commonDeviceVendorInfo OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Equipment suppliers of other special designated information"
|
||
::= { commonDeviceInfoEntry 6 }
|
||
|
||
commonDeviceStatus OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"
|
||
Bit 0: RSVD0
|
||
Bit 1: RSVD1
|
||
Bit 2: RSVD2
|
||
Bit 3: MAJOR ALARMS
|
||
Bit 4: MINOR ALARMS
|
||
Bit 5: RSVD5
|
||
Bit 6: RSVD6
|
||
Bit 7: RSVD7"
|
||
::= { commonDeviceInfoEntry 7 }
|
||
|
||
commonDeviceReset OBJECT-TYPE
|
||
SYNTAX INTEGER { reset (1) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Write'1 'will be reset equipment, other values will be written into the non-functional. Reading this object return value'1 ', the equipment had no effect."
|
||
::= { commonDeviceInfoEntry 8 }
|
||
|
||
commonDeviceAlarmDetectionControl OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
detectionDisabled (1),
|
||
detectionEnabled (2),
|
||
detectionEnabledAndRegenerate (3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This object used to control equipment alarm detection. "
|
||
::= { commonDeviceInfoEntry 9 }
|
||
|
||
commonDeviceMACAddress OBJECT-TYPE
|
||
SYNTAX NetworkAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Equipment MAC address"
|
||
::= { commonDeviceInfoEntry 10 }
|
||
|
||
commonDeviceTamperStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { intact (1), compromised (2) }
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Report of the safety switch equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, compromised expressed alarm."
|
||
::= { commonDeviceInfoEntry 11 }
|
||
|
||
commonDeviceInternalTemperature OBJECT-TYPE
|
||
SYNTAX INTEGER (-128..127)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table"
|
||
::= { commonDeviceInfoEntry 12 }
|
||
|
||
commonDeviceResetCause OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other (1),
|
||
powerup (2),
|
||
command (3),
|
||
watchdog (4),
|
||
craft (5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Equipment that the reasons for the recent reduction"
|
||
::= { commonDeviceInfoEntry 13 }
|
||
|
||
commonDeviceCraftStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disconnected (1),
|
||
connected (2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This object interface that local equipment (such as RS232 or RS485 interface) state."
|
||
::= { commonDeviceInfoEntry 14 }
|
||
|
||
commonDevicesOID OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Goals identifier string, point to a concrete realization of the equipment"
|
||
::= { commonDeviceInfoEntry 15 }
|
||
|
||
commonDeviceAcct OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Equipment that the accumulated work time, units of s"
|
||
::= { commonDeviceInfoEntry 16 }
|
||
|
||
commonDeviceName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Equipment name"
|
||
::= { commonDeviceInfoEntry 17 }
|
||
|
||
commonDeviceMFD OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(10))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Equipment manufacturing date."
|
||
::= { commonDeviceInfoEntry 18 }
|
||
|
||
commonDeviceFW OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Equipment firmware information"
|
||
::= { commonDeviceInfoEntry 19 }
|
||
|
||
|
||
|
||
|
||
|
||
hfcColdStart TRAP-TYPE
|
||
ENTERPRISE nscrtvHFCemsTree
|
||
VARIABLES { commonPhysAddress, commonNELogicalID}
|
||
DESCRIPTION
|
||
"HfcColdStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement may have changed. This trap only after the success of transponder sent registration"
|
||
::= 0
|
||
|
||
hfcWarmStart TRAP-TYPE
|
||
ENTERPRISE nscrtvHFCemsTree
|
||
VARIABLES { commonPhysAddress, commonNELogicalID }
|
||
DESCRIPTION
|
||
"HfcWarmStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement has not changed. This trap only after the completion of transponder sent registration"
|
||
|
||
::= 2
|
||
|
||
|
||
--*********************************************************************************************
|
||
-- Optical Switch MIB
|
||
--*********************************************************************************************
|
||
oswVendorOID OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object provides manufacturers of optical switch MIB expansion. Without the expansion, this should be targeting at the optical switch nodes oswIdent"
|
||
::= { oswIdent 1 }
|
||
oswMode OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..3 )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The work modes of the optical switch:'1' indicates the switch choose route B£»'2' indicates the switch choose route A£»'3' indicates the switch choose any one output route¡£"
|
||
::= { oswIdent 2 }
|
||
|
||
oswSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..65535 )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Optical switch breaking point"
|
||
::= { oswIdent 3 }
|
||
|
||
-- ****************
|
||
-- * ͨµÀ²ÎÊý
|
||
-- ****************
|
||
oswChannelTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF OswChannelEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Optical Switch Information Table"
|
||
::= { oswIdent 4 }
|
||
|
||
oswChannelEntry OBJECT-TYPE
|
||
SYNTAX OswChannelEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Optical Switch Information Table Head"
|
||
INDEX { oswIndex }
|
||
::= { oswChannelTable 1 }
|
||
|
||
OswChannelEntry ::=
|
||
SEQUENCE
|
||
{
|
||
oswUnitTemp
|
||
INTEGER,
|
||
oswInputA
|
||
INTEGER,
|
||
oswInputB
|
||
INTEGER,
|
||
oswOutput1
|
||
INTEGER,
|
||
oswOutput2
|
||
INTEGER
|
||
}
|
||
|
||
oswUnitTemp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Chassis temperature of the Optical switch, unit in 1 centigrade degree."
|
||
::= { oswChannelEntry 1 }
|
||
|
||
oswInputA OBJECT-TYPE
|
||
SYNTAX INTEGER ( -128..127 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The input optical power of route A, unit in 0.1 dBm, this object require entry register in the attribute MIB."
|
||
::= { oswChannelEntry 2 }
|
||
|
||
oswInputB OBJECT-TYPE
|
||
SYNTAX INTEGER ( -128..127 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The input optical power of route B, unit in 0.1 dBm, this object require entry register in the attribute MIB."
|
||
::= { oswChannelEntry 3 }
|
||
|
||
oswOutput1 OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..65535 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The input optical power of route 1, unit in 0.1 dBm, this object require entry register in the attribute MIB."
|
||
::= { oswChannelEntry 4 }
|
||
|
||
oswOutput2 OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..65535 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The input optical power of route 2, unit in 0.1 dBm, this object require entry register in the attribute MIB."
|
||
::= { oswChannelEntry 5 }
|
||
|
||
|
||
-- *****************
|
||
-- * Ö±Á÷µçÔ´
|
||
-- *****************
|
||
|
||
oswNumberDCPowerSupply OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..16 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of internal DC power supply,'0 'indicates the transponder nonsupport this function."
|
||
::= { oswIdent 5 }
|
||
|
||
oswDCPowerSupplyMode OBJECT-TYPE
|
||
SYNTAX INTEGER { loadsharing(1), switchedRedundant(2), aloneSupply(3)}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Power supply work modes: Load and load-sharing, standby switch, or independency power supply. If the equipment has only one DC power supply, this should not be supported."
|
||
::= { oswIdent 6 }
|
||
|
||
oswDCPowerTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF OswDCPowerEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"DC Power Information Table"
|
||
::= { oswIdent 7 }
|
||
|
||
oswDCPowerEntry OBJECT-TYPE
|
||
SYNTAX OswDCPowerEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"DC Power Information Table Head"
|
||
INDEX { oswDCPowerIndex }
|
||
::= { oswDCPowerTable 1 }
|
||
|
||
OswDCPowerEntry ::=SEQUENCE
|
||
{
|
||
oswDCPowerIndex
|
||
INTEGER,
|
||
oswDCPowerVoltage
|
||
INTEGER,
|
||
oswDCPowerCurrent
|
||
INTEGER,
|
||
oswDCPowerName
|
||
DisplayString
|
||
}
|
||
|
||
oswDCPowerIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"DC Power Index, table oswDCPowerTable index"
|
||
::= { oswDCPowerEntry 1 }
|
||
|
||
oswDCPowerVoltage OBJECT-TYPE
|
||
SYNTAX INTEGER ( -32768..32767 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Power supply voltage, unit in 0.1 V, this object require entry register in the attribute MIB."
|
||
::= { oswDCPowerEntry 2 }
|
||
|
||
oswDCPowerCurrent OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..65535 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Power supply current, unit in 0.1 A, this object require entry register in the attribute MIB."
|
||
::= { oswDCPowerEntry 3 }
|
||
|
||
oswDCPowerName OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Mark Power supply name, for example: +5 V DC power supply.
|
||
This field value regulated by the user, it should be marked with the number of the power supply voltage and distinguish the multi-power supplies at least.
|
||
When the object in this table give an alarm, the name of this object should be put into the alarmText target in the hfcAlarmEvent trap.
|
||
"
|
||
::= { oswDCPowerEntry 4 }
|
||
|
||
|
||
END
|