ADTRAN-DYNAMIC-COUNTERS-MIB
DEFINITIONS ::= BEGIN
-- TITLE: The ADTRAN CN DYNAMIC COUNTERS MIB
-- PRODUCT: Modules that support dynamic counters (SM, GE, GPON, AE, ...)
-- VERSION: 1.0
-- DATE: Feb 11, 2013
--
-- This MIB Contains tables for dynamic counter creation and reporting on CN products.
--
-- HISTORY: * PLEASE DO NOT ADD ANY REVISION HISTORY HERE! USE REVISION/DESCRIPTION!
--
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, IpAddress, Gauge32, Counter64
FROM SNMPv2-SMI
RowStatus, PhysAddress, DisplayString
FROM SNMPv2-TC
InterfaceIndexOrZero
FROM IF-MIB
adIdentity
FROM ADTRAN-MIB
adGenSlotInfoIndex
FROM ADTRAN-GENSLOT-MIB
adGenDynamicCounter, adGenDynamicCounterID
FROM ADTRAN-SHARED-CND-SYSTEM-MIB;
adGenDynamicCounterMIB MODULE-IDENTITY
LAST-UPDATED "201407310000Z"
ORGANIZATION "ADTRAN, Inc."
CONTACT-INFO
"CND Tech Support
Postal: ADTRAN, Inc.
901 Explorer Blvd.
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"Adtran Dynamic Counter MIB"
REVISION "201407310000Z"
DESCRIPTION "updated adGenDCProfileDiscardReason with none(11)"
REVISION "201406050000Z"
DESCRIPTION "Added adGenDCProfileEgressQueueType,adGenDCProfileEgressQueue,
adGenDCProfileCtagVlanType, adGenDCProfileCtagVlan,
adGenDCProfileCtagPriType, adGenDCProfileCtagPri,
adGenDCProfileEvcMap, adGenDCProfileDiscardReason"
REVISION "201302110000Z"
DESCRIPTION "Creation"
::= { adGenDynamicCounterID 1 }
--
-- Object Hierarchy
--
adGenDynamicCounterTables OBJECT IDENTIFIER ::= { adGenDynamicCounter 1 }
--
-- Textual Conventions
--
--
-- Dynamic Counter Slot Table
--
adGenDCSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenDCSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides information about dynamic counter slot support."
::= { adGenDynamicCounterTables 1 }
adGenDCSlotEntry OBJECT-TYPE
SYNTAX AdGenDCSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides information about dynamic counter slot support."
INDEX { adGenSlotInfoIndex }
::= { adGenDCSlotTable 1 }
AdGenDCSlotEntry ::=
SEQUENCE {
adGenDCSlotSupport BITS,
adGenDCSlotMaxDCProfileIndex Integer32,
adGenDCSlotNextDCProfileIndex Integer32,
adGenDCSlotMaxDCIndex Integer32,
adGenDCSlotNextDCIndex Integer32,
adGenDCSlotClearAllDC INTEGER,
adGenDCSlotLastError DisplayString
}
adGenDCSlotSupport OBJECT-TYPE
SYNTAX BITS {
color (0),
pBit (1),
sTag (2),
destMacByType (3),
destMac (4),
destIpByType (5),
destIp (6),
srcMacByType (7),
srcMac (8),
srcIpByType (9),
srcIp (10),
ipAndMac (11),
destAndSrc (12),
tx (13),
rx (14),
queue (15),
include (16),
exclude (17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the dynamic counter matching types supported
by the slot. Each bit will be set if the matching type
can be used in adGenDCProfileTable. The values are:
color - can use adGenDCProfileColorType
pBit - can use adGenDCProfilePBitType and adGenDCProfilePBit
sTag - can use adGenDCProfileSTagType and adGenDCProfileSTag
destMacByType - can use adGenDCProfileDestMacType
destMac - can use adGenDCProfileDestMacAddress
destIpByType - can use adGenDCProfileDestIpType
destIp - can use adGenDCProfileDestIpAddress
srcMacByType - can use adGenDCProfileSrcMacType
srcMac - can use adGenDCProfileSrcMacAddress
srcIpByType - can use adGenDCProfileSrcIpType
srcIp - can use adGenDCProfileSrcIpAddress
ipAndMac - can match IP and MAC in the same profile
destAndSrc - can match destination and source in the same profile
tx - can count transmit statistics
rx - can count receive statistics
queue - can count queue statistics
include - supports including the match in the counts
exclude - supports excluding the match in the counts
"
::= { adGenDCSlotEntry 1 }
adGenDCSlotMaxDCProfileIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum index value that can be used for the dynamic counter
profile index on this slot."
::= { adGenDCSlotEntry 2 }
adGenDCSlotNextDCProfileIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the next free index for a dynamic counter profile.
Reports 0 if there is no available entry."
::= { adGenDCSlotEntry 3 }
adGenDCSlotMaxDCIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum index value that can be used for the dynamic counter
index on this slot."
::= { adGenDCSlotEntry 4 }
adGenDCSlotNextDCIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the next free index for a dynamic counter.
Reports 0 if there is no available entry."
::= { adGenDCSlotEntry 5 }
adGenDCSlotClearAllDC OBJECT-TYPE
SYNTAX INTEGER {
clearAll (1),
idle (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This will always report idle. To clear all dynamic counter
counts on the slot, write clearAll to this element."
::= { adGenDCSlotEntry 6 }
adGenDCSlotLastError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The details of the last error seen at the slot level,
based on queries to this entry. The main use may be to
report the error when there are no more entries available."
::= { adGenDCSlotEntry 7 }
--
-- Dynamic Counter Profile Configuration Table
--
adGenDCProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenDCProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides information about dynamic counter matching criteria."
::= { adGenDynamicCounterTables 2 }
adGenDCProfileEntry OBJECT-TYPE
SYNTAX AdGenDCProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides information about dynamic counter matching criteria."
INDEX { adGenSlotInfoIndex, adGenDCProfileIndex }
::= { adGenDCProfileTable 1 }
AdGenDCProfileEntry ::=
SEQUENCE {
adGenDCProfileIndex Integer32,
adGenDCProfileRowStatus RowStatus,
adGenDCProfileColorType INTEGER,
adGenDCProfilePBitType INTEGER,
adGenDCProfilePBit INTEGER,
adGenDCProfileSTagType INTEGER,
adGenDCProfileSTag INTEGER,
adGenDCProfileDestMacType INTEGER,
adGenDCProfileDestMacAddress PhysAddress,
adGenDCProfileDestIpType INTEGER,
adGenDCProfileDestIpAddress IpAddress,
adGenDCProfileSrcMacType INTEGER,
adGenDCProfileSrcMacAddress PhysAddress,
adGenDCProfileSrcIpType INTEGER,
adGenDCProfileSrcIpAddress IpAddress,
adGenDCProfileLastError DisplayString,
adGenDCProfileEgressQueueType INTEGER,
adGenDCProfileEgressQueue INTEGER,
adGenDCProfileCtagVlanType INTEGER,
adGenDCProfileCtagVlan INTEGER,
adGenDCProfileCtagPriType INTEGER,
adGenDCProfileCtagPri INTEGER,
adGenDCProfileEvcMap DisplayString,
adGenDCProfileDiscardReason INTEGER
}
adGenDCProfileIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies the index of the dynamic counter profile.
The index will be from 1 to N, where N is the maximum
number of dynamic counters supported by the module."
::= { adGenDCProfileEntry 1 }
adGenDCProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new counter profile and
delete an existing counter profile. To create, write
createAndWait(5) or createAndGo(4) to this element. To
delete, write destroy(6) to this element. The values
for notInService(2) and notReady(3) are not used.
The element will always report active(1), once created."
::= { adGenDCProfileEntry 2 }
adGenDCProfileColorType OBJECT-TYPE
SYNTAX INTEGER {
noMatching (1),
green (2),
yellow (3),
red (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify the color of the traffic to be matched in this
profile. The default is noMatching, which means the
color will not be used in this profile."
::= { adGenDCProfileEntry 3 }
adGenDCProfilePBitType OBJECT-TYPE
SYNTAX INTEGER {
noMatching (1),
pBit (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify whether the P-Bit is being matched in this
profile. The default is noMatching, which means the
P-Bit will not be used in this profile. If pBit
is set, then the matched P-Bit value is specified in
adGenDCProfilePBit."
::= { adGenDCProfileEntry 4 }
adGenDCProfilePBit OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify a P-Bit value being matched in this
profile when adGenDCProfilePBitType is set to pBit.
This is unused if adGenDCProfilePBitType is set to
anything else. This value defaults to 0."
::= { adGenDCProfileEntry 5 }
adGenDCProfileSTagType OBJECT-TYPE
SYNTAX INTEGER {
noMatching (1),
sTag (2),
allSTags (3),
noSTag (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify whether the S-Tag is being matched in this
profile. The default is noMatching, which means the
S-Tag will not be used in this profile.
If sTag is set, then the matching S-Tag value is
specified in adGenDCProfileSTag.
If allSTags is set, then this will match all packets
that have an S-Tag, regardless of value.
If noSTag is set, then this will match all packets
that do not have an S-Tag."
::= { adGenDCProfileEntry 6 }
adGenDCProfileSTag OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify an S-Tag value being matched in this
profile when adGenDCProfileSTagType is set to sTag.
This is unused if adGenDCProfileSTagType is set to
anything else. This value defaults to 0."
::= { adGenDCProfileEntry 7 }
adGenDCProfileDestMacType OBJECT-TYPE
SYNTAX INTEGER {
noMatching (1),
mac (2),
unicast (3),
multicast (4),
broadcast (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify whether the destination MAC is being matched in
this profile. The default is noMatching, which means the
MAC will not be used in this profile. If mac is set,
then the matched destination MAC value is specified in
adGenDCProfileDestMacAddress.
If unicast is set, then this will match all packets
that have a unicast destination MAC address.
If multicast is set, then this will match all packets
that have a multicast destination MAC address.
If broadcast is set, then this will match all packets
that have a broadcast destination MAC address."
::= { adGenDCProfileEntry 8 }
adGenDCProfileDestMacAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify a destination MAC address being matched in this
profile when adGenDCProfileDestMacType is set to mac.
This is unused if adGenDCProfileDestMacType is set to
anything else. This defaults to all-0's."
::= { adGenDCProfileEntry 9 }
adGenDCProfileDestIpType OBJECT-TYPE
SYNTAX INTEGER {
noMatching (1),
ip (2),
unicast (3),
multicast (4),
any (5),
none (6)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify whether the destination IP is being matched in
this profile. The default is noMatching, which means the
IP will not be used in this profile. If ip is set,
then the matched destination IP value is specified in
adGenDCProfileDestIpAddress.
If unicast is set, then this will match all packets
that have a unicast destination IP address.
If multicast is set, then this will match all packets
that have a multicast destination IP address.
If any is set, then this will match all packets
that have an IP address (i.e. all L3 packets).
If none is set, then this will match all packets
that do not have an IP address (i.e. L2 packets only)."
::= { adGenDCProfileEntry 10 }
adGenDCProfileDestIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify a destination IP address being matched in this
profile when adGenDCProfileDestIpType is set to ip.
This is unused if adGenDCProfileDestIpType is set to
anything else. This defaults to all-0's."
::= { adGenDCProfileEntry 11 }
adGenDCProfileSrcMacType OBJECT-TYPE
SYNTAX INTEGER {
noMatching (1),
mac (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify whether the source MAC is being matched in
this profile. The default is noMatching, which means the
MAC will not be used in this profile. If mac is set,
then the matched source MAC value is specified in
adGenDCProfileSrcMacAddress."
::= { adGenDCProfileEntry 12 }
adGenDCProfileSrcMacAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify a source MAC address being matched in this
profile when adGenDCProfileSrcMacType is set to mac.
This is unused if adGenDCProfileSrcMacType is set to
anything else. This defaults to all-0's."
::= { adGenDCProfileEntry 13 }
adGenDCProfileSrcIpType OBJECT-TYPE
SYNTAX INTEGER {
noMatching (1),
ip (2),
any (3),
none (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify whether the source IP is being matched in
this profile. The default is noMatching, which means the
IP will not be used in this profile. If ip is set,
then the matched source IP value is specified in
adGenDCProfileSrcIpAddress.
If any is set, then this will match all packets
that have a source IP address (i.e. all L3 packets).
If none is set, then this will match all packets
that do not have a source IP address (i.e. L2 packets only)."
::= { adGenDCProfileEntry 14 }
adGenDCProfileSrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify a source IP address being matched in this
profile when adGenDCProfileSrcIpType is set to ip.
This is unused if adGenDCProfileSrcIpType is set to
anything else. This defaults to all-0's."
::= { adGenDCProfileEntry 15 }
adGenDCProfileLastError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The details of the last error seen for a profile,
based on queries to this entry."
::= { adGenDCProfileEntry 16 }
adGenDCProfileEgressQueueType OBJECT-TYPE
SYNTAX INTEGER {
noMatching (1),
egressQueue (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify whether the Egress queue is being matched in this
profile.
If egressQueue is set, then the matching egress Queue value is
specified in adGenDCProfileEgressQueue."
DEFVAL { noMatching }
::= { adGenDCProfileEntry 17 }
adGenDCProfileEgressQueue OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Egress queue number."
DEFVAL { 0 }
::= { adGenDCProfileEntry 18 }
adGenDCProfileCtagVlanType OBJECT-TYPE
SYNTAX INTEGER {
noMatching (1),
cTag (2),
allCTags (3),
noCTag (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify whether the C-Tag is being matched in this
profile.
If cTag is set, then the matching C-Tag value is
specified in adGenDCProfileCtagVlan.
If allCTags is set, then this will match all packets
that have an C-Tag, regardless of value.
If noCTag is set, then this will match all packets
that do not have an C-Tag."
DEFVAL { noMatching }
::= { adGenDCProfileEntry 19 }
adGenDCProfileCtagVlan OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Customer VLAN ID used to identify traffic"
DEFVAL { 0 }
::= { adGenDCProfileEntry 20 }
adGenDCProfileCtagPriType OBJECT-TYPE
SYNTAX INTEGER {
noMatching (1),
cTagPri (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify whether the CTag is being matched in this
profile. If cTagPri is set, then the matched CTag
value is specified in adGenDCProfileCtagPri."
DEFVAL { noMatching }
::= { adGenDCProfileEntry 21 }
adGenDCProfileCtagPri OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Priority used by the C-Tag on traffic meeting the match criteria."
DEFVAL { 0 }
::= { adGenDCProfileEntry 22 }
adGenDCProfileEvcMap OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Name of the EVC map. If null string is set, matching is disabled.
Null string will be the default."
::= { adGenDCProfileEntry 23 }
adGenDCProfileDiscardReason OBJECT-TYPE
SYNTAX INTEGER {
noMatching(1),
any(2),
stagMatchFailed(3),
egressRecDrop(4),
forwardingFailed(5),
fullQueue(6),
invalidQueueDrop(7),
lagNotValid(8),
multicastBufferFull(9),
macsaMatchFailed(10),
none(11)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Configures the dynamic counter to count packets that
have been dropped due to one of the enumerated drop criteria.
Discard reason 'none(11)' means that all packets that
are NOT dropped are counted."
DEFVAL { noMatching }
::= { adGenDCProfileEntry 24 }
--
-- Dynamic Counter Configuration Table
--
adGenDCConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenDCConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides information about dynamic counter configuration.
This tables connects a profile and an interface into a
dynamic counter entry."
::= { adGenDynamicCounterTables 3 }
adGenDCConfigEntry OBJECT-TYPE
SYNTAX AdGenDCConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides information about dynamic counter configuration."
INDEX { adGenSlotInfoIndex, adGenDCConfigIndex }
::= { adGenDCConfigTable 1 }
AdGenDCConfigEntry ::=
SEQUENCE {
adGenDCConfigIndex Integer32,
adGenDCConfigRowStatus RowStatus,
adGenDCConfigProfile Integer32,
adGenDCConfigInterface InterfaceIndexOrZero,
adGenDCConfigType INTEGER,
adGenDCConfigInterfaceQueue Integer32,
adGenDCConfigInclude INTEGER,
adGenDCConfigLastError DisplayString
}
adGenDCConfigIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the dynamic counter."
::= { adGenDCConfigEntry 1 }
adGenDCConfigRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This element provides the administrative state.
This object is used to create a new dynamic counter,
delete an existing dynamic counter, and to enable/disable
the dynamic counter. To create or delete, write
createAndWait(5) or destroy(6) to this element.
To enable/disable the dynamic counter, write
active(1) or notInService(2) to this element. The
value for createAndGo(4) will not be used. If the
dynamic counter is requested to go inService when it
does not have sufficient information, the request will fail
and the error will be listed in adGenDCConfigLastError."
::= { adGenDCConfigEntry 2 }
adGenDCConfigProfile OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The index of the adGenDCProfile that will be used."
::= { adGenDCConfigEntry 3 }
adGenDCConfigInterface OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IfIndex of the interface that will be used."
::= { adGenDCConfigEntry 4 }
adGenDCConfigType OBJECT-TYPE
SYNTAX INTEGER {
tx (1),
rx (2),
queue (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of the statistics to be gathered, either
tx, rx, or queue statistics. The statistics types
are only supported if indicated in adGenDCSlotSupport.
If queue is specified, the queue number is indicated
in adGenDCConfigInterfaceQueue."
::= { adGenDCConfigEntry 5 }
adGenDCConfigInterfaceQueue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the queue number, if adGenDCConfigType
is set to queue."
::= { adGenDCConfigEntry 6 }
adGenDCConfigInclude OBJECT-TYPE
SYNTAX INTEGER {
include (1),
exclude (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the match to the counter profile
should be included in the counts or excluded from
the counts. The default value is to include them in
the counts. This setting is subject to the settings
in adGenDCSlotSupport."
::= { adGenDCConfigEntry 7 }
adGenDCConfigLastError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The details of the last error seen for a dynamic counter,
based on queries to this entry. This may include
invalid values, reasons for rejecting configuration
items, or reasons the counter cannot go running."
::= { adGenDCConfigEntry 8 }
--
-- Dynamic Counter Status Table
--
adGenDCStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenDCStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides status about the dynamic counter table, including
counts that have been collected."
::= { adGenDynamicCounterTables 4 }
adGenDCStatusEntry OBJECT-TYPE
SYNTAX AdGenDCStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides status about the dynamic counter table, including
counts that have been collected."
INDEX { adGenSlotInfoIndex, adGenDCConfigIndex }
::= { adGenDCStatusTable 1 }
AdGenDCStatusEntry ::=
SEQUENCE {
adGenDCStatusRowStatus RowStatus,
adGenDCStatusOctets Counter64,
adGenDCStatusPkts Counter64,
adGenDCStatusAvgBitsPerSec Gauge32,
adGenDCStatusClear INTEGER
}
adGenDCStatusRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to report the operational status
of the dynamic counters, either inService or notReady."
::= { adGenDCStatusEntry 1 }
adGenDCStatusOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets / bytes counted by this dynamic counter."
::= { adGenDCStatusEntry 2 }
adGenDCStatusPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets counted by this dynamic counter."
::= { adGenDCStatusEntry 3 }
adGenDCStatusAvgBitsPerSec OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average number of bits per second counted on the dynamic counter
during the last 5 minutes."
::= { adGenDCStatusEntry 4 }
adGenDCStatusClear OBJECT-TYPE
SYNTAX INTEGER {
clear (1),
idle (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This will always report idle. To clear the dynamic counter
counts, write clear(1) to this element."
::= { adGenDCStatusEntry 5 }
END