Observium_CE/mibs/hh3c/HH3C-MAC-INFORMATION-MIB

601 lines
21 KiB
Plaintext

-- ============================================================================
-- Copyright (c) 2004-2022 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: The purpose of this MIB file is to provide the definition of
-- the MAC Information general configuration.
-- Reference:
-- Version: V1.3
-- History:
-- V1.0 2007-12-28
-- Initial version, created by gejianzhuang
-- V1.1 2009-08-13
-- Add 'hh3cMACInformationTrapObjectsExt' by gejianzhuang
-- V1.2 2013-05-02
-- Add 'hh3cMACInformationMovedTrap' by yangjie
-- V1.3 2022-08-08
-- Add 'hh3cMACInformationMovedRsmTrap'
-- And 'hh3cMACInfoVsiMovedTrap'
-- And 'hh3cMACInfoVsiMovedRsmTrap'
-- And 'hh3cMACInfoTrapMsgMovedVsi'
-- And 'hh3cMACInfoTrapMsgMovedFmIfName'
-- And 'hh3cMACInfoTrapMsgMovedToIfName' by wangyuqing
-- ============================================================================
HH3C-MAC-INFORMATION-MIB DEFINITIONS ::= BEGIN
IMPORTS
hh3cCommon
FROM HH3C-OID-MIB
Unsigned32, Counter32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Integer32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, MacAddress
FROM SNMPv2-TC
ifIndex
FROM IF-MIB;
-- Node definitions
hh3cMACInformation MODULE-IDENTITY
LAST-UPDATED "202208081800Z" -- AUG 08, 2022 at 18:00 GMT
ORGANIZATION
"New H3C Technologies Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Technologies Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip: 100085"
DESCRIPTION
"This MIB file is to provide the definition of the MAC Information
general configuration. MAC Information feature is used to
make that the changed MAC information in the monitored device is
knowable in remote monitoring device."
REVISION "202208081800Z"
DESCRIPTION
"Add the objects of hh3cMACInformationMovedRsmTrap, hh3cMACInfoVsiMovedTrap,
hh3cMACInfoVsiMovedRsmTrap, hh3cMACInfoTrapMsgMovedVsi, hh3cMACInfoTrapMsgMovedFmIfName
and hh3cMACInfoTrapMsgMovedToIfName."
REVISION "200712281912Z"
DESCRIPTION
"The initial version of this MIB file."
::= { hh3cCommon 87 }
Hh3cMACInfoWorkMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The working mode of the MAC Information feature."
SYNTAX INTEGER
{
trap(1),
syslog(2)
}
hh3cMACInformationObjects OBJECT IDENTIFIER ::= { hh3cMACInformation 1 }
hh3cMACInformationMibGlobal OBJECT IDENTIFIER ::= { hh3cMACInformationObjects 1 }
hh3cMACInformationMIBTableTroop OBJECT IDENTIFIER ::= { hh3cMACInformationObjects 2 }
hh3cMACInformationMibTrap OBJECT IDENTIFIER ::= { hh3cMACInformationObjects 3 }
hh3cMACInformationMibTrapExt OBJECT IDENTIFIER ::= { hh3cMACInformationObjects 4 }
hh3cMACInformationEnabled OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value is a global setting. The feature will not work until the
value is set to enabled(1). If the value is set to disabled(2),
the feature will stop working even there are interfaces that have
been enabled the feature."
DEFVAL { disabled }
::= { hh3cMACInformationMibGlobal 1 }
hh3cMACInformationcSendInterval OBJECT-TYPE
SYNTAX Unsigned32(1..20000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum interval that the device generate syslogs or traps.
The unit is second."
DEFVAL { 1 }
::= { hh3cMACInformationMibGlobal 2 }
hh3cMACInformationLearntMACNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MAC addresses that learnt by the device since the
hh3cMACInformationEnabled is set to enabled(1) and hh3cMACLearntEnable
is set to enabled(1) at least on one interface. If the hh3cMACInformationEnabled
is set to disabled(2), the object will always return 0."
::= { hh3cMACInformationMibGlobal 3 }
hh3cMACInformationRemovedMACNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MAC addresses that removed by the device since the
hh3cMACInformationEnabled is set to enabled(1) and hh3cMACRemovedEnable
is set to enabled(1) at least on one interface. If the hh3cMACInformationEnabled
is set to disabled(2), the object will always return 0."
::= { hh3cMACInformationMibGlobal 4 }
hh3cMACInformationTrapSendNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of traps that have been generated. This object is valid
only when the hh3cMACInfomationWorkMode is set to trap(1). If the
hh3cMACInfomationWorkMode is set to syslog(2), the object will always return 0."
::= { hh3cMACInformationMibGlobal 5 }
hh3cMACInformationSyslogSendNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of syslogs that have been generated. This object is valid only
when the hh3cMACInfomationWorkMode is set to syslog(2). If the
hh3cMACInfomationWorkMode is set to trap(1), the object will always return 0."
::= { hh3cMACInformationMibGlobal 6 }
hh3cMACInformationCacheLen OBJECT-TYPE
SYNTAX Unsigned32(0..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum queue lenth used to cache the changed MAC addresses information
in the monitored device. If the value is set to 0, syslog or trap will generate
as soon as there is a MAC address learnt or removed."
DEFVAL { 50 }
::= { hh3cMACInformationMibGlobal 7 }
hh3cMACInfomationWorkMode OBJECT-TYPE
SYNTAX Hh3cMACInfoWorkMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The working mode of MAC Information feature. If the object is
set to trap(1), the device will use trap mode to notify the MAC
address information and all properties of trap interrelated is
valid. If the object is set to syslog(2), the device will use
syslog mode to notify the MAC address information and all
properties of trap interrelated is invalid."
::= { hh3cMACInformationMibGlobal 8}
--hh3cMACInfomationIfTable
hh3cMACInfomationIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cMACInfomationIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to enable or disable the MAC Information feature
on interfaces."
::= { hh3cMACInformationMIBTableTroop 1 }
hh3cMACInfomationIfEntry OBJECT-TYPE
SYNTAX Hh3cMACInfomationIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of hh3cMACInfomationIfTable."
INDEX
{
ifIndex
}
::= { hh3cMACInfomationIfTable 1 }
Hh3cMACInfomationIfEntry ::= SEQUENCE
{
hh3cMACLearntEnable INTEGER,
hh3cMACRemovedEnable INTEGER
}
hh3cMACLearntEnable OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the object is set to enabled(1) on interface, the device
will cache the MAC address information that learnt on the interface."
DEFVAL { disabled }
::= { hh3cMACInfomationIfEntry 1 }
hh3cMACRemovedEnable OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the object is set to enable(1) on interface, the device
will cache the MAC address information that removed on the interface."
DEFVAL { disabled }
::= { hh3cMACInfomationIfEntry 2 }
-- hh3cMACNotificationTrap
hh3cMACInformationTraps OBJECT IDENTIFIER ::= { hh3cMACInformationMibTrap 0 }
hh3cMACInformationChangedTrap NOTIFICATION-TYPE
OBJECTS
{
hh3cMACInfoTrapIndex,
hh3cMACInfoTrapCount,
hh3cMACInfoTrapMsg
}
STATUS current
DESCRIPTION
"When the cached number of MAC address information is reached the
value specified by hh3cMACInformationCacheLen, trap is generated
and is sent to the remote monitoring device. The trap is also
generated when the amount of time elapsed since the previous
notification is greater than the interval value specified by
hh3cMACInformationcSendInterval and there is at least one cached
MAC address information learnt or removed. The object is valid
only when hh3cMACInfomationWorkMode is set to trap(1). When the
hh3cMACInfomationWorkMode is set to syslog(2), No trap will be
generated even hh3cMACInformationEnabled is set to enabled(1) and
the feature is enabled on interface."
::= { hh3cMACInformationTraps 1 }
hh3cMACInformationTrapObjects OBJECT IDENTIFIER ::= { hh3cMACInformationMibTrap 2 }
hh3cMACInfoTrapIndex OBJECT-TYPE
SYNTAX Unsigned32(1..4294967295)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The sequence number of trap information. When it reaches the
maximum value, it should be set to 1."
::= { hh3cMACInformationTrapObjects 1 }
hh3cMACInfoTrapCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The cell number of the current trap information. The trap
message may consists of more than one MAC address information.
Each of the one MAC address information in one trap is called cell."
::= { hh3cMACInformationTrapObjects 2 }
hh3cMACInfoTrapMsg OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..254))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object is the MAC information that learnt or removed
in the monitored device. It can consists of more than
one MAC information in the object.
This object is in the format of '<cell1><cell2>...'. Each
cell consists of 12 octets in the format of
'<operationType><VLAN><MAC><MACtype><ifIndex>'.
<operationType> is the reason type of MAC address changed and have
size of 1 octet. It only supports the following values.
1 - MAC learnt.
2 - MAC removed.
<VLAN> is the vlan number that correspond to the MAC address in
MAC address table and has size of 2 octet.
<MAC> is the MAC address and has size of 6 octets.
<MACtype> is the MAC address type and has size of 1 octet. It only
supports the following values.
0 - Unknown
1 - Learnt
2 - Config dynamic
3 - Config static
4 - Blackhole
5 - Security
6 - 802.1x
7 - MAC authentication
8 - Voice VLAN
9 - Reserved
<ifIndex> is the index of the interface where the MAC
address is learnt or removed and has size of 2 octets."
::= { hh3cMACInformationTrapObjects 3 }
-- hh3cMACNotificationTrapExt
hh3cMACInformationTrapsExt OBJECT IDENTIFIER ::= { hh3cMACInformationMibTrapExt 0 }
hh3cMACInformationChangedTrapExt NOTIFICATION-TYPE
OBJECTS
{
hh3cMACInfoTrapVerExt,
hh3cMACInfoTrapIndexExt,
hh3cMACInfoTrapCountExt,
hh3cMACInfoTrapMsgExt
}
STATUS current
DESCRIPTION
"When the cached number of MAC address information is reached the
value specified by hh3cMACInformationCacheLen, trap is generated
and is sent to the remote monitoring device. The trap is also
generated when the amount of time elapsed since the previous
notification is greater than the interval value specified by
hh3cMACInformationcSendInterval and there is at least one cached
MAC address information learnt or removed. The object is valid
only when hh3cMACInfomationWorkMode is set to trap(1). When the
hh3cMACInfomationWorkMode is set to syslog(2), No trap will be
generated even hh3cMACInformationEnabled is set to enabled(1) and
the feature is enabled on interface."
::= { hh3cMACInformationTrapsExt 1 }
hh3cMACInformationMovedTrap NOTIFICATION-TYPE
OBJECTS
{
hh3cMACInfoTrapMsgMovedAddress,
hh3cMACInfoTrapMsgMovedVlan,
hh3cMACInfoTrapMsgMovedFromIf,
hh3cMACInfoTrapMsgMovedToIf,
hh3cMACInfoTrapMsgMovedCount,
hh3cMACInfoTrapMsgChassis,
hh3cMACInfoTrapMsgSlot
}
STATUS current
DESCRIPTION
"When the MAC address has been moved to another interface, trap
is generated and is sent to the remote monitoring device."
::= { hh3cMACInformationTrapsExt 2 }
hh3cMACInformationMovedRsmTrap NOTIFICATION-TYPE
OBJECTS
{
hh3cMACInfoTrapMsgMovedVlan,
hh3cMACInfoTrapMsgChassis,
hh3cMACInfoTrapMsgSlot
}
STATUS current
DESCRIPTION
"In this cycle, this trap information is reported when the MAC address in the VLAN no longer migrates."
::= { hh3cMACInformationTrapsExt 3 }
hh3cMACInfoVsiMovedTrap NOTIFICATION-TYPE
OBJECTS
{
hh3cMACInfoTrapMsgMovedAddress,
hh3cMACInfoTrapMsgMovedVsi,
hh3cMACInfoTrapMsgMovedFmIfName,
hh3cMACInfoTrapMsgMovedToIfName,
hh3cMACInfoTrapMsgMovedCount,
hh3cMACInfoTrapMsgChassis,
hh3cMACInfoTrapMsgSlot
}
STATUS current
DESCRIPTION
"When the MAC address has been moved to another interface in the VSI, trap
is generated and is sent to the remote monitoring device."
::= { hh3cMACInformationTrapsExt 4 }
hh3cMACInfoVsiMovedRsmTrap NOTIFICATION-TYPE
OBJECTS
{
hh3cMACInfoTrapMsgMovedVsi,
hh3cMACInfoTrapMsgChassis,
hh3cMACInfoTrapMsgSlot
}
STATUS current
DESCRIPTION
"In this cycle, this trap information is reported when the MAC address in the VSI no longer migrates."
::= { hh3cMACInformationTrapsExt 5 }
hh3cMACInfoMovedIfBlockTrap NOTIFICATION-TYPE
OBJECTS
{
hh3cMACInfoTrapMsgBlockIfName,
hh3cMACInfoTrapMsgBlockTime,
hh3cMACInfoTrapMsgMovedAddress,
hh3cMACInfoTrapMsgMovedVlan
}
STATUS current
DESCRIPTION
"When the MAC migration suppression function is enabled, the interface is down for a
certain time due to frequent migration, and this trap information is reported."
::= { hh3cMACInformationTrapsExt 6 }
hh3cMACInfoMovedIfResumeTrap NOTIFICATION-TYPE
OBJECTS
{
hh3cMACInfoTrapMsgBlockIfName,
hh3cMACInfoTrapMsgBlockTime,
hh3cMACInfoTrapMsgMovedVlan
}
STATUS current
DESCRIPTION
"When the MAC migration suppression function is enabled, the interface is up after
the interface is down for a certain time due to frequent migration, and this trap
information is reported."
::= { hh3cMACInformationTrapsExt 7 }
hh3cMACInformationTrapObjectsExt OBJECT IDENTIFIER ::= { hh3cMACInformationMibTrapExt 2 }
hh3cMACInfoTrapVerExt OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The version of trap information."
::= { hh3cMACInformationTrapObjectsExt 1 }
hh3cMACInfoTrapIndexExt OBJECT-TYPE
SYNTAX Unsigned32(1..4294967295)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The sequence number of trap information. When it reaches the
maximum value, it should be set to 1."
::= { hh3cMACInformationTrapObjectsExt 2 }
hh3cMACInfoTrapCountExt OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The cell number of the current trap information. The trap
message may consists of more than one MAC address information.
Each of the one MAC address information in one trap is called cell."
::= { hh3cMACInformationTrapObjectsExt 3 }
hh3cMACInfoTrapMsgExt OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..254))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object is the MAC information that learnt or removed
in the monitored device. It can consists of more than
one MAC information in the object.
This object is in the format of '<cell1><cell2>...'. Each
cell consists of 14 octets in the format of
'<operationType><VLAN><MAC><MACtype><ifIndex>'.
<operationType> is the reason type of MAC address changed and have
size of 1 octet. It only supports the following values.
1 - MAC learnt.
2 - MAC removed.
<VLAN> is the vlan number that correspond to the MAC address in
MAC address table and has size of 2 octet.
<MAC> is the MAC address and has size of 6 octets.
<MACtype> is the MAC address type and has size of 1 octet. It only
supports the following values.
0 - Unknown
1 - Learnt
2 - Config dynamic
3 - Config static
4 - Blackhole
5 - Security
6 - 802.1x
7 - MAC authentication
8 - Voice VLAN
9 - Reserved
<ifIndex> is the index of the interface where the MAC
address is learnt or removed and has size of 4 octets."
::= { hh3cMACInformationTrapObjectsExt 4 }
hh3cMACInfoTrapMsgMovedAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The MAC address that is moved between interfaces."
::= { hh3cMACInformationTrapObjectsExt 5 }
hh3cMACInfoTrapMsgMovedVlan OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The VLAN number in which the MAC address is moved."
::= { hh3cMACInformationTrapObjectsExt 6}
hh3cMACInfoTrapMsgMovedFromIf OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of the interface from which the MAC address is moved."
::= { hh3cMACInformationTrapObjectsExt 7 }
hh3cMACInfoTrapMsgMovedToIf OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of the interface to which the MAC address is moved."
::= { hh3cMACInformationTrapObjectsExt 8 }
hh3cMACInfoTrapMsgMovedCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The times for which the MAC address has been moved between the
interfaces."
::= { hh3cMACInformationTrapObjectsExt 9 }
hh3cMACInfoTrapMsgMovedVsi OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..31))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The name of VSI in which the MAC address is moved."
::= { hh3cMACInformationTrapObjectsExt 10 }
hh3cMACInfoTrapMsgMovedFmIfName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..255))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The name of the interface from which the MAC address is moved."
::= { hh3cMACInformationTrapObjectsExt 11 }
hh3cMACInfoTrapMsgMovedToIfName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..255))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The name of the interface to which the MAC address is moved."
::= { hh3cMACInformationTrapObjectsExt 12 }
hh3cMACInfoTrapMsgChassis OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The information of chassis ID. If the value is 65535, the device is
not a stacked device ."
::= { hh3cMACInformationTrapObjectsExt 13 }
hh3cMACInfoTrapMsgSlot OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The information of slot."
::= { hh3cMACInformationTrapObjectsExt 14 }
hh3cMACInfoTrapMsgBlockIfName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..255))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The name of the interface."
::= { hh3cMACInformationTrapObjectsExt 15 }
hh3cMACInfoTrapMsgBlockTime OBJECT-TYPE
SYNTAX Unsigned32(30..86400)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The time of MAC migration suppression, and the unit of time is seconds."
::= { hh3cMACInformationTrapObjectsExt 16 }
END