-- Copyright (c) 2004-2021 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: GIR MIB
-- Reference:
-- Version: V1.0
-- History:
-- V1.0 Initial version, created by wangmeng
-- =====================================================================
HH3C-GIR-MIB DEFINITIONS ::= BEGIN
IMPORTS
hh3cCommon
FROM HH3C-OID-MIB
Integer32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI;
hh3cGir MODULE-IDENTITY
LAST-UPDATED "202107011126Z" -- July 01, 2021 at 11:26 GMT
ORGANIZATION
"New H3C Technologies Co., Ltd."
CONTACT-INFO
"
Platform Team New H3C Tech. Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip:100085
"
DESCRIPTION
"
Graceful insertion and removal (GIR) enables you to gracefully isolate
the device from the network for device maintenance or upgrade.
"
REVISION "202107011126Z"
DESCRIPTION
"The initial revision of this MIB module."
::= { hh3cCommon 205 }
--
-- Node definitions
--
hh3cGirObjects OBJECT IDENTIFIER ::= { hh3cGir 1 }
hh3cGirSystemGroup OBJECT IDENTIFIER ::= { hh3cGirObjects 1 }
hh3cGirSystemMode OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
isolation(2),
shutdown(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Change system mode.
normal-Normal mode(Default).
isolation-Maintenance mode by isolation.
shutdown-Maintenance mode by shutdown.
"
::= { hh3cGirSystemGroup 1 }
hh3cGirRevertDelayTime OBJECT-TYPE
SYNTAX Integer32 (0 | 5..65535)
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Auto change to normal mode after the specified amount of time in
minutes. If 0 is set, no switchback will be performed.
"
DEFVAL { 0 }
::= { hh3cGirSystemGroup 2 }