Observium_CE/mibs/h3c/H3C-FC-PING-MIB

359 lines
12 KiB
Plaintext

-- =====================================================================
-- Copyright (c) 2004-2013 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
--
-- Description:
-- This MIB module is for the management of the Fibre Channel
-- Ping functionality.
-- Reference:
-- Version: V1.0
-- History:
-- V1.0 Initial version created by liuyanchao 2013-03-15
-- =====================================================================
H3C-FC-PING-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32
FROM SNMPv2-SMI
RowStatus, TruthValue
FROM SNMPv2-TC
H3cFcVsanIndex, H3cFcAddressType, H3cFcAddress,
H3cFcStartOper
FROM H3C-FC-TC-MIB
h3cSan
FROM H3C-VSAN-MIB;
h3cFcPing MODULE-IDENTITY
LAST-UPDATED "201303150000Z"
ORGANIZATION "Hangzhou H3C Tech. Co., Ltd."
CONTACT-INFO
"Platform Team Hangzhou H3C Tech. Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip:100085"
DESCRIPTION
"This MIB module is for the management of the Fibre Channel
Ping functionality."
REVISION "201303150000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { h3cSan 5 }
h3cFcPingObjects OBJECT IDENTIFIER
::= { h3cFcPing 1 }
h3cFcPingConfigurations OBJECT IDENTIFIER
::= { h3cFcPingObjects 1 }
h3cFcPingStatistics OBJECT IDENTIFIER
::= { h3cFcPingObjects 2 }
h3cFcPingNotifications OBJECT IDENTIFIER
::= { h3cFcPingObjects 3 }
h3cFcPingNotifyPrefix OBJECT IDENTIFIER
::= { h3cFcPingNotifications 0 }
-- FC Ping table
h3cFcPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cFcPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of FC ping entries containing a group of
FC ping requests that need to be executed at the
agent."
::= { h3cFcPingConfigurations 1 }
h3cFcPingEntry OBJECT-TYPE
SYNTAX H3cFcPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A FC ping request entry that need to be executed
at the agent."
INDEX { h3cFcPingIndex }
::= { h3cFcPingTable 1 }
H3cFcPingEntry ::= SEQUENCE {
h3cFcPingIndex Unsigned32,
h3cFcPingVsan H3cFcVsanIndex,
h3cFcPingAddressType H3cFcAddressType,
h3cFcPingAddress H3cFcAddress,
h3cFcPingPacketCount Unsigned32,
h3cFcPingPayloadSize Unsigned32,
h3cFcPingTimeout Unsigned32,
h3cFcPingDelay Unsigned32,
h3cFcPingAgeInterval Unsigned32,
h3cFcPingAdminStatus H3cFcStartOper,
h3cFcPingOperStatus INTEGER,
h3cFcPingTrapOnCompletion TruthValue,
h3cFcPingRowStatus RowStatus
}
h3cFcPingIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of the current FC ping entry. This object
identifies a FC ping request entry uniquely in a
specified VSAN (Virtual Storage Area Network)."
::= { h3cFcPingEntry 1 }
h3cFcPingVsan OBJECT-TYPE
SYNTAX H3cFcVsanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VSAN on which the FC ping request will be
performed. If the corresponding instance value of
h3cFcPingOperStatus is 'inProgress', the object
cannot be modified."
::= { h3cFcPingEntry 2 }
h3cFcPingAddressType OBJECT-TYPE
SYNTAX H3cFcAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of the corresponding instance of
h3cFcPingAddress object."
DEFVAL { fcid }
::= { h3cFcPingEntry 3 }
h3cFcPingAddress OBJECT-TYPE
SYNTAX H3cFcAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The address to which the route will be pinged.
This object will contain an 8 octet long WWN(World Wide Name),
if the value of the associated instance of h3cFcPingAddressType
object is 'wwn'.
This object will contain a 3 octet long Fibre Channel Address ID,
if the value of the associated instance of h3cFcPingAddressType
object is 'fcid'."
::= { h3cFcPingEntry 4 }
h3cFcPingPacketCount OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of FC ping packets to be sent to the
target in this sequence."
DEFVAL { 5 }
::= { h3cFcPingEntry 5 }
h3cFcPingPayloadSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the size of the FC ping packet
payload to be sent to the target in this sequence."
::= { h3cFcPingEntry 6 }
h3cFcPingTimeout OBJECT-TYPE
SYNTAX Unsigned32 (1..10)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of timeout for this FC ping request."
DEFVAL { 5 }
::= { h3cFcPingEntry 7 }
h3cFcPingDelay OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum amount of time to wait before sending
the next packet in a sequence, after receiving a
response or declaring a timeout for a previously
transmitted packet."
::= { h3cFcPingEntry 8 }
h3cFcPingAgeInterval OBJECT-TYPE
SYNTAX Unsigned32 (500..900)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The interval time after a FC ping test completes
before the entry is aged out."
DEFVAL { 500 }
::= { h3cFcPingEntry 9 }
h3cFcPingAdminStatus OBJECT-TYPE
SYNTAX H3cFcStartOper
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The administrative status of each h3cFcPingEntry.
The object has two values:
enable - Activate the entry.
disable - Deactivate the entry.
When the FC ping entry is executing, this object cannot be
modified. If this object is read at such a time, a value of
'enable' will be returned. When the test finishes, the value
of this object will be set to 'disable'."
DEFVAL { disable }
::= { h3cFcPingEntry 10 }
h3cFcPingOperStatus OBJECT-TYPE
SYNTAX INTEGER {
inProgress(1), -- FC ping in progress
complete(2), -- FC ping complete
disabled(3), -- FC ping disabled
failed(4) -- FC ping failed
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the operational status
of this h3cFcPingEntry.
The value specifications are listed as follows:
inProgress - FC ping is in progress.
complete - FC ping is complete.
disabled - FC ping is disabled.
failed - FC ping has failed due to resource limitations."
::= { h3cFcPingEntry 11 }
h3cFcPingTrapOnCompletion OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates that if h3cFcPingCompletionNotify
notification should be generated or not when the corresponding
ping sequence completes."
DEFVAL { false }
::= { h3cFcPingEntry 12 }
h3cFcPingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this conceptual row."
::= { h3cFcPingEntry 13 }
-- FC Ping Statistics Table
h3cFcPingStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cFcPingStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of FC ping statistics.
This table notes the FC ping statistics of a FC ping test
associated with an entry in the h3cFcPingTable."
::= { h3cFcPingStatistics 1 }
h3cFcPingStatEntry OBJECT-TYPE
SYNTAX H3cFcPingStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A FC ping statistics entry.
An entry will be created automatically in this table when the
h3cFcPingRowStatus of a ping request in the h3cFcPingTable
is set to 'active'.
The entry in this table will have the same indices as the entry
that in the h3cFcPingTable.
An entry in this table will be deleted when the corresponding
entry in the h3cFcPingTable is deleted."
INDEX { h3cFcPingIndex }
::= { h3cFcPingStatTable 1 }
H3cFcPingStatEntry ::= SEQUENCE {
h3cFcPingReqPackets Unsigned32,
h3cFcPingResPackets Unsigned32,
h3cFcPingMinTime Integer32,
h3cFcPingAverageTime Integer32,
h3cFcPingMaxTime Integer32,
h3cFcPingTimeoutNum Unsigned32
}
h3cFcPingReqPackets OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of FC ping packets request in this sequence."
::= { h3cFcPingStatEntry 1 }
h3cFcPingResPackets OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of FC ping packets response in this sequence."
::= { h3cFcPingStatEntry 2 }
h3cFcPingMinTime OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum round trip time of all the packets that
have been sent in this sequence."
::= { h3cFcPingStatEntry 3 }
h3cFcPingAverageTime OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round trip time of all the packets that
have been sent in this sequence."
::= { h3cFcPingStatEntry 4 }
h3cFcPingMaxTime OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum round trip time of all the packets that
have been sent in this sequence."
::= { h3cFcPingStatEntry 5 }
h3cFcPingTimeoutNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of timeouts encountered in this sequence."
::= { h3cFcPingStatEntry 6 }
-- Notifications
h3cFcPingCompletionNotify NOTIFICATION-TYPE
OBJECTS { h3cFcPingIndex,
h3cFcPingVsan,
h3cFcPingAddressType,
h3cFcPingAddress,
h3cFcPingReqPackets,
h3cFcPingResPackets}
STATUS current
DESCRIPTION
"When a FC ping test is finished and the instance of
h3cFcPingTrapOnCompletion associated with the test
is set to 'true', this notification occurred."
::= { h3cFcPingNotifyPrefix 1 }
END