-- EKINOPS-Pmops.TXT: MIB
--
--MIB Part Number:3MI00303AFAD
--MIB Version:01
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
--
-- *****************************************************************
EKINOPS-Pmops-MIB DEFINITIONS ::= BEGIN
IMPORTS
ekinops,
EkiState,
EkiOnOff,
EkiMode,
EkiProtocol,
EkiApiState,
EkiSynchroMode,
EkiMeasureType
FROM EKINOPS-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32,
Counter32,
IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString
FROM SNMPv2-TC;
modulePmops MODULE-IDENTITY
LAST-UPDATED "201605230000Z"
ORGANIZATION "Ekinops"
CONTACT-INFO
"Ekinops
3, rue Blaise Pascal
F-22300 Lannion / FRANCE
Tel : +33 (0)2 96 05 00 30
Fax : +33 (0)2 96 48 62 39
E-mail: support@ekinops.net"
DESCRIPTION
"MIB for the Ekinops Pmops hardware."
REVISION "200712110000Z"
DESCRIPTION
"Initial Version."
REVISION "200801230000Z"
DESCRIPTION
"Helps on objects, Ports Labels"
REVISION "200909240000Z"
DESCRIPTION
"CondType parameters insertion"
REVISION "201002260000Z"
DESCRIPTION
"Probcause,AlarmType - NMS"
REVISION "201005270000Z"
DESCRIPTION
"Dummy INV for NMS"
REVISION "201011040000Z"
DESCRIPTION
"Formulas in comments"
REVISION "201012150000Z"
DESCRIPTION
"Formulas in comments"
REVISION "201207040000Z"
DESCRIPTION
"Minor cosmetic updates"
REVISION "201403260000Z"
DESCRIPTION
"Probcause,AlarmType - NMS completion"
REVISION "201411210000Z"
DESCRIPTION
"Labels cosmetic updates"
REVISION "201605230000Z"
DESCRIPTION
"New AlarmType synthesisAlarm (12)"
::= { ekinops 30 }
--- *****************************************************
--- LEAF LEVEL 2
--- *****************************************************
pmopsalarms OBJECT IDENTIFIER ::= { modulePmops 2 }
pmopsAlmOther OBJECT IDENTIFIER ::= { pmopsalarms 1 }
pmopsAlmOtherNurg OBJECT IDENTIFIER ::= { pmopsAlmOther 1 }
pmopsAlmOtherUrg OBJECT IDENTIFIER ::= { pmopsAlmOther 2 }
pmopsAlmOtherCrit OBJECT IDENTIFIER ::= { pmopsAlmOther 3 }
pmopsAlmComa OBJECT IDENTIFIER ::= { pmopsalarms 2 }
pmopsAlmComaNurg OBJECT IDENTIFIER ::= { pmopsAlmComa 1 }
pmopsAlmComaUrg OBJECT IDENTIFIER ::= { pmopsAlmComa 2 }
pmopsAlmComaCrit OBJECT IDENTIFIER ::= { pmopsAlmComa 3 }
pmopsAlmComb OBJECT IDENTIFIER ::= { pmopsalarms 3 }
pmopsAlmCombNurg OBJECT IDENTIFIER ::= { pmopsAlmComb 1 }
pmopsAlmCombUrg OBJECT IDENTIFIER ::= { pmopsAlmComb 2 }
pmopsAlmCombCrit OBJECT IDENTIFIER ::= { pmopsAlmComb 3 }
pmopsmeasures OBJECT IDENTIFIER ::= { modulePmops 3 }
pmopsMesrOther OBJECT IDENTIFIER ::= { pmopsmeasures 1 }
pmopsMesrComa OBJECT IDENTIFIER ::= { pmopsmeasures 2 }
pmopsMesrComb OBJECT IDENTIFIER ::= { pmopsmeasures 3 }
pmopscontrolsWrite OBJECT IDENTIFIER ::= { modulePmops 6 }
pmopsCtrlOther OBJECT IDENTIFIER ::= { pmopscontrolsWrite 1 }
pmopsCtrlComa OBJECT IDENTIFIER ::= { pmopscontrolsWrite 2 }
pmopsCtrlComb OBJECT IDENTIFIER ::= { pmopscontrolsWrite 3 }
pmopsri OBJECT IDENTIFIER ::= { modulePmops 7 }
pmopsriTable OBJECT IDENTIFIER ::= { pmopsri 1 }
pmopsConfig OBJECT IDENTIFIER ::= { modulePmops 9 }
pmopstraps OBJECT IDENTIFIER ::= { modulePmops 10 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
PmopsSwitchMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "different switch mode for port"
SYNTAX INTEGER {
switchManual1(1),
switchManual2(2),
switchAuto(4),
switchAutoRevertive(8)
}
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pmopsRinvReloadInventory OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reload the inventory: This OID triggers an
inventory reload."
::= { pmopsri 2 }
pmopsRinvHwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HW platform description: This OID contains the
description of the Hardware platform."
::= { pmopsri 3 }
pmopsRinvModulePlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module platform description: This OID contains the
description of the Module."
::= { pmopsri 4 }
pmopsRinvSwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW platform description: This OID contains the
description of the Software platform."
::= { pmopsri 5 }
pmopsRinvLine1SFP OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the OPS: This OID contains the inventory for the OPS A"
::= { pmopsri 6 }
pmopsRinvLine2SFP OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the OPS: This OID contains the inventory for the OPS B"
::= { pmopsri 7 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synthAlm0 article
--- *****************************************************
pmopsAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmopsAlmOtherCrit 0 }
pmopsAlmDefFuseB OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse B Fail :This OID indicates
that the fuse of the power input
B is in fail condition <Help>
Status of the Fuse B <Condtype>
DEF_FUSE_B <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmsynthAlm0 16 }
pmopsAlmDefFuseA OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse A Fail :This OID indicates
that the fuse of the power input
A is in fail condition <Help>
Status of the Fuse A <Condtype>
DEF_FUSE_A <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmsynthAlm0 15 }
pmopsAlmModuleGlobFailure OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Failure :This OID is set
on detection of a failure originating
from the PM <Condtype> MODULE_GLOB_FAILURE
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmopsAlmsynthAlm0 9 }
--- *****************************************************
--- LEAF for the synthAlm2 article
--- *****************************************************
pmopsAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmopsAlmOtherNurg 2 }
pmopsAlmCorrelatOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Not Used :This OID, when set,
indicates that alarm correlation
is not being performed. <Condtype>
CORRELAT_OFF <Probcause> other
(1) <Alarmtype> other (1) <Polarity>
(2)
"
::= { pmopsAlmsynthAlm2 4 }
pmopsAlmConfTableLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Load :This OID
is at 1 during the loading of
configuration tables in the modules
RAM. <Condtype> CONF_TABLE_LOAD
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmopsAlmsynthAlm2 3 }
pmopsAlmInvUpload OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Inventory Upload :This OID is
at 1 during the uploading of PM
inventory information. <Condtype>
INV_UPLOAD <Probcause> other (1)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmopsAlmsynthAlm2 2 }
pmopsAlmConfTableSave OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Save :This OID
is at 1 during the saving of a
new configuration table in the
module Flash memory. <Condtype>
CONF_TABLE_SAVE <Probcause> other
(1) <Alarmtype> other (1) <Polarity>
(2)
"
::= { pmopsAlmsynthAlm2 1 }
--- *****************************************************
--- LEAF for the synthAlmComa article
--- *****************************************************
pmopsAlmsynthAlmComa OBJECT IDENTIFIER ::= { pmopsAlmComaCrit 8 }
pmopsAlmComaFailAcc OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fail_Acc :This OID indicates a
failure on the OPS A <Condtype>
COMA_FAIL_ACC <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmopsAlmsynthAlmComa 12 }
pmopsAlmComaMeasAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Measure Alarm :This OID indicates
an alarm is present coming out
of OPS A diagnostic monitoring
<Help> This alarm indicates if
a diagnostic monitoring Alarm has
been detected on the OPS A <Condtype>
COMA_MEAS_ALM <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmopsAlmsynthAlmComa 10 }
pmopsAlmComaMeasWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Measure Warning :This OID indicates
a warning is present coming out
of OPS A diagnostic monitoring
<Help> This alarm indicates if
a diagnostic monitoring Warning
has been detected on the OPS A
<Condtype> COMA_MEAS_WNG <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmopsAlmsynthAlmComa 9 }
pmopsAlmComaLocalOos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Out Of Service :This OID indicates
that the OPS A is In Service (1)
of Out or Service (2). <Help>
This status indicates if the OPS
A is in service <Condtype> COMA_LOCAL_OOS
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmopsAlmsynthAlmComa 6 }
pmopsAlmComaHwFailAcc OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
HW_Fail_Acc :This OID indicates
a hardware failure on the OPS A
<Condtype> COMA_HW_FAIL_ACC <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmopsAlmsynthAlmComa 4 }
--- *****************************************************
--- LEAF for the synthAlmComb article
--- *****************************************************
pmopsAlmsynthAlmComb OBJECT IDENTIFIER ::= { pmopsAlmCombCrit 9 }
pmopsAlmCombFailAcc OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fail_Acc :This OID indicates a
failure on the OPS B <Condtype>
COMB_FAIL_ACC <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmopsAlmsynthAlmComb 12 }
pmopsAlmCombMeasAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Measure Alarm :This OID indicates
an alarm is present coming out
of OPS B diagnostic monitoring
<Help> This alarm indicates if
a diagnostic monitoring Alarm has
been detected on the OPS B <Condtype>
COMB_MEAS_ALM <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmopsAlmsynthAlmComb 10 }
pmopsAlmCombMeasWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Measure Warning :This OID indicates
a warning is present coming out
of OPS B diagnostic monitoring
<Help> This alarm indicates
if a diagnostic monitoring Warning
has been detected on the OPS B
<Condtype> COMB_MEAS_WNG <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmopsAlmsynthAlmComb 9 }
pmopsAlmCombLocalOos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Out Of Service :This OID indicates
that the OPS B is In Service (1)
of Out or Service (2). <Help>
This status indicates if the OPS
B is in service <Condtype> COMB_LOCAL_OOS
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmopsAlmsynthAlmComb 6 }
pmopsAlmCombHwFailAcc OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
HW_Fail_Acc :This OID indicates
a hardware failure on the OPS B
<Condtype> COMB_HW_FAIL_ACC <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmopsAlmsynthAlmComb 4 }
--- *****************************************************
--- LEAF for the comaAccessioAlm article
--- *****************************************************
pmopsAlmcomaAccessioAlm OBJECT IDENTIFIER ::= { pmopsAlmComaUrg 16 }
pmopsAlmComaSwitchFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Switch Fail :This OID indicates
the OPS A switch component in in
fail condition <Help> This alarm
indicates if the OPS A swithc is
in fail condition <Condtype> COMA_SWITCH_FAIL
<Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcomaAccessioAlm 8 }
pmopsAlmComaSwitchPosition2 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX2 Selected :This OID indicates
the OPS A selects the RX 2 input
<Help> This status indicates
if the RX2 input is selected on
the OPS A <Condtype> COMA_SWITCH_POSITION_2
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmopsAlmcomaAccessioAlm 6 }
pmopsAlmComaSwitchPosition1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX1 Selected :This OID indicates
the OPS A selects the RX 1 input
<Help> This status indicates
if the RX 1 input is selected
on the OPS A <Condtype> COMA_SWITCH_POSITION_1
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmopsAlmcomaAccessioAlm 5 }
pmopsAlmComaLosTx2 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
TX2 Loss Of Signal :This OID indicates
that a LOS is detected on the Transmit
2 of the OPS A <Help> This alarm
indicates if an optical signal
is detected on the TX 2 of the
OPS A <Condtype> COMA_LOS_TX_2
<Probcause> transmitFailure (55)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmopsAlmcomaAccessioAlm 4 }
pmopsAlmComaLosTx1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
TX1 Loss Of Signal :This OID indicates
that a LOS is detected on the Transmit
1 of the OPS A <Help> This alarm
indicates if an optical signal
is detected on the TX 1 of the
OPS A <Condtype> COMA_LOS_TX_1
<Probcause> transmitFailure (55)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmopsAlmcomaAccessioAlm 3 }
pmopsAlmComaLosRx2 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX2 Loss Of Signal :This OID indicates
that a LOS is detected on the Receive
2 of the OPS A <Help> This alarm
indicates if an optical signal
is detected on the RX 2 of the
OPS A <Condtype> COMA_LOS_RX_2
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmopsAlmcomaAccessioAlm 2 }
pmopsAlmComaLosRx1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX1 Loss Of Signal :This OID indicates
that a LOS is detected on the Receive
1 of the OPS A <Help> This alarm
indicates if an optical signal
is detected on the RX 1 of the
OPS A <Condtype> COMA_LOS_RX_1
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmopsAlmcomaAccessioAlm 1 }
--- *****************************************************
--- LEAF for the comaMeasAlm article
--- *****************************************************
pmopsAlmcomaMeasAlm OBJECT IDENTIFIER ::= { pmopsAlmComaUrg 17 }
pmopsAlmComaRx2PwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx2 High Alarm : This OID indicates
that Receive power or the OPS A
is higher than the alarm threshold
of the OPS A <Help> This alarm
indicates if the receive power
on the receive side of the OPS
A is too high <Condtype> COMA_RX2_PWR_HIGH_ALA
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcomaMeasAlm 8 }
pmopsAlmComaRx2PwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx2 Low Alarm :This OID indicates
that Receive power or the OPS A
is lower than the alarm threshold
of the OPS A <Help> This alarm
indicates if the receive power
on the receive side of the OPS
A is too low <Condtype> COMA_RX2_PWR_LOW_ALA
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcomaMeasAlm 7 }
pmopsAlmComaTx2PwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx2 High Alarm : This OID indicates
that Transmit power or the OPS
A is higher than the alarm threshold
of the OPS A <Help> This alarm
indicates if the receive power
on the transmit side of the OPS
A is too high <Condtype> COMA_TX2_PWR_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcomaMeasAlm 6 }
pmopsAlmComaTx2PwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx2 Low Alarm :This OID indicates
that Transmit power or the OPS
A is lower than the alarm threshold
of the OPS A <Help> This alarm
indicates if the receive power
on the transmit side of the OPS
A is too low <Condtype> COMA_TX2_PWR_LOW_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcomaMeasAlm 5 }
pmopsAlmComaRx1PwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx1 High Alarm : This OID indicates
that Receive power or the OPS A
is higher than the alarm threshold
of the OPS A <Help> This alarm
indicates if the receive power
on the receive side of the OPS
A is too high <Condtype> COMA_RX1_PWR_HIGH_ALA
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcomaMeasAlm 4 }
pmopsAlmComaRx1PwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx1 Low Alarm :This OID indicates
that Receive power or the OPS A
is lower than the alarm threshold
of the OPS A <Help> This alarm
indicates if the receive power
on the receive side of the OPS
A is too low <Condtype> COMA_RX1_PWR_LOW_ALA
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcomaMeasAlm 3 }
pmopsAlmComaTx1PwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx1 High Alarm : This OID indicates
that Transmit power or the OPS
A is higher than the alarm threshold
of the OPS A <Help> This alarm
indicates if the receive power
on the transmit side of the OPS
A is too high <Condtype> COMA_TX1_PWR_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcomaMeasAlm 2 }
pmopsAlmComaTx1PwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx1 Low Alarm :This OID indicates
that Transmit power or the OPS
A is lower than the alarm threshold
of the OPS A <Help> This alarm
indicates if the receive power
on the transmit side of the OPS
A is too low <Condtype> COMA_TX1_PWR_LOW_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcomaMeasAlm 1 }
--- *****************************************************
--- LEAF for the comaMeasWng article
--- *****************************************************
pmopsAlmcomaMeasWng OBJECT IDENTIFIER ::= { pmopsAlmComaNurg 18 }
pmopsAlmComaRx2PwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx2 High Warning : This OID indicates
that Receive power or the OPS A
is higher than the warning threshold
of the OPS A <Help> This warning
indicates if the receive power
on the receive side of the OPS
A is too high <Condtype> COMA_RX2_PWR_HIGH_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcomaMeasWng 8 }
pmopsAlmComaRx2PwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx2 Low Warning :This OID indicates
that Receive power or the OPS A
is lower than the warning threshold
of the OPS A <Help> This warning
indicates if the receive power
on the receive side of the OPS
A is too low <Condtype> COMA_RX2_PWR_LOW_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcomaMeasWng 7 }
pmopsAlmComaTx2PwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx2 High Warning : This OID indicates
that Transmit power or the OPS
A is higher than the warning threshold
of the OPS A <Help> This warning
indicates if the receive power
on the transmit side of the OPS
A is too high <Condtype> COMA_TX2_PWR_HIGH_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcomaMeasWng 6 }
pmopsAlmComaTx2PwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx2 Low Warning :This OID indicates
that Transmit power or the OPS
A is lower than the warning threshold
of the OPS A <Help> This warning
indicates if the receive power
on the transmit side of the OPS
A is too low <Condtype> COMA_TX2_PWR_LOW_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcomaMeasWng 5 }
pmopsAlmComaRx1PwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx1 High Warning : This OID indicates
that Receive power or the OPS A
is higher than the warning threshold
of the OPS A <Help> This warning
indicates if the receive power
on the receive side of the OPS
A is too high <Condtype> COMA_RX1_PWR_HIGH_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcomaMeasWng 4 }
pmopsAlmComaRx1PwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx1 Low Warning :This OID indicates
that Receive power or the OPS A
is lower than the warning threshold
of the OPS A <Help> This warning
indicates if the receive power
on the receive side of the OPS
A is too low <Condtype> COMA_RX1_PWR_LOW_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcomaMeasWng 3 }
pmopsAlmComaTx1PwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx1 High Warning : This OID indicates
that Transmit power or the OPS
A is higher than the warning threshold
of the OPS A <Help> This warning
indicates if the receive power
on the transmit side of the OPS
A is too high <Condtype> COMA_TX1_PWR_HIGH_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcomaMeasWng 2 }
pmopsAlmComaTx1PwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx1 Low Warning :This OID indicates
that Transmit power or the OPS
A is lower than the warning threshold
of the OPS A <Help> This warning
indicates if the receive power
on the transmit side of the OPS
A is too low <Condtype> COMA_TX1_PWR_LOW_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcomaMeasWng 1 }
--- *****************************************************
--- LEAF for the combAccessioAlm article
--- *****************************************************
pmopsAlmcombAccessioAlm OBJECT IDENTIFIER ::= { pmopsAlmCombUrg 24 }
pmopsAlmCombSwitchFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Switch Fail :This OID indicates
the OPS B switch component in in
fail condition <Help> This alarm
indicates if the OPS B swithc is
in fail condition <Condtype> COMB_SWITCH_FAIL
<Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcombAccessioAlm 8 }
pmopsAlmCombSwitchPosition2 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX2 Selected :This OID indicates
the OPS B selects the RX 2 input
<Help> This status indicates
if the RX2 input is selected on
the OPS B <Condtype> COMB_SWITCH_POSITION_2
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmopsAlmcombAccessioAlm 6 }
pmopsAlmCombSwitchPosition1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX1 Selected :This OID indicates
the OPS B selects the RX 1 input
<Help> This status indicates
if the RX 1 input is selected
on the OPS B <Condtype> COMB_SWITCH_POSITION_1
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmopsAlmcombAccessioAlm 5 }
pmopsAlmCombLosTx2 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
TX2 Loss Of Signal :This OID indicates
that a LOS is detected on the Transmit
2 of the OPS B <Help> This alarm
indicates if an optical signal
is detected on the TX 2 of the
OPS B <Condtype> COMB_LOS_TX_2
<Probcause> transmitFailure (55)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmopsAlmcombAccessioAlm 4 }
pmopsAlmCombLosTx1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
TX1 Loss Of Signal :This OID indicates
that a LOS is detected on the Transmit
1 of the OPS B <Help> This alarm
indicates if an optical signal
is detected on the TX 1 of the
OPS B <Condtype> COMB_LOS_TX_1
<Probcause> transmitFailure (55)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmopsAlmcombAccessioAlm 3 }
pmopsAlmCombLosRx2 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX2 Loss Of Signal :This OID indicates
that a LOS is detected on the Receive
2 of the OPS B <Help> This alarm
indicates if an optical signal
is detected on the RX 2 of the
OPS B <Condtype> COMB_LOS_RX_2
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmopsAlmcombAccessioAlm 2 }
pmopsAlmCombLosRx1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX1 Loss Of Signal :This OID indicates
that a LOS is detected on the Receive
1 of the OPS B <Help> This alarm
indicates if an optical signal
is detected on the RX 1 of the
OPS B <Condtype> COMB_LOS_RX_1
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmopsAlmcombAccessioAlm 1 }
--- *****************************************************
--- LEAF for the combMeasAla article
--- *****************************************************
pmopsAlmcombMeasAla OBJECT IDENTIFIER ::= { pmopsAlmCombUrg 25 }
pmopsAlmCombRx2PwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx2 High Alarm : This OID indicates
that Receive power or the OPS B
is higher than the alarm threshold
of the OPS B <Help> This alarm
indicates if the receive power
on the receive side of the OPS
B is too high <Condtype> COMB_RX2_PWR_HIGH_ALA
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcombMeasAla 8 }
pmopsAlmCombRx2PwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx2 Low Alarm :This OID indicates
that Receive power or the OPS B
is lower than the alarm threshold
of the OPS B <Help> This alarm
indicates if the receive power
on the receive side of the OPS
B is too low <Condtype> COMB_RX2_PWR_LOW_ALA
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcombMeasAla 7 }
pmopsAlmCombTx2PwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx2 High Alarm : This OID indicates
that Transmit power or the OPS
B is higher than the alarm threshold
of the OPS B <Help> This alarm
indicates if the receive power
on the transmit side of the OPS
B is too high <Condtype> COMB_TX2_PWR_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcombMeasAla 6 }
pmopsAlmCombTx2PwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx2 Low Alarm :This OID indicates
that Transmit power or the OPS
B is lower than the alarm threshold
of the OPS B <Help> This alarm
indicates if the receive power
on the transmit side of the OPS
B is too low <Condtype> COMB_TX2_PWR_LOW_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcombMeasAla 5 }
pmopsAlmCombRx1PwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx1 High Alarm : This OID indicates
that Receive power or the OPS B
is higher than the alarm threshold
of the OPS B <Help> This alarm
indicates if the receive power
on the receive side of the OPS
B is too high <Condtype> COMB_RX1_PWR_HIGH_ALA
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcombMeasAla 4 }
pmopsAlmCombRx1PwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx1 Low Alarm :This OID indicates
that Receive power or the OPS B
is lower than the alarm threshold
of the OPS B <Help> This alarm
indicates if the receive power
on the receive side of the OPS
B is too low <Condtype> COMB_RX1_PWR_LOW_ALA
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcombMeasAla 3 }
pmopsAlmCombTx1PwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx1 High Alarm : This OID indicates
that Transmit power or the OPS
B is higher than the alarm threshold
of the OPS B <Help> This alarm
indicates if the receive power
on the transmit side of the OPS
B is too high <Condtype> COMB_TX1_PWR_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcombMeasAla 2 }
pmopsAlmCombTx1PwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx1 Low Alarm :This OID indicates
that Transmit power or the OPS
B is lower than the alarm threshold
of the OPS B <Help> This alarm
indicates if the receive power
on the transmit side of the OPS
B is too low <Condtype> COMB_TX1_PWR_LOW_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcombMeasAla 1 }
--- *****************************************************
--- LEAF for the combMeasWng article
--- *****************************************************
pmopsAlmcombMeasWng OBJECT IDENTIFIER ::= { pmopsAlmCombNurg 26 }
pmopsAlmCombRx2PwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx2 High Warning : This OID indicates
that Receive power or the OPS B
is higher than the warning threshold
of the OPS B <Help> This warning
indicates if the receive power
on the receive side of the OPS
B is too high <Condtype> COMB_RX2_PWR_HIGH_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcombMeasWng 8 }
pmopsAlmCombRx2PwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx2 Low Warning :This OID indicates
that Receive power or the OPS B
is lower than the warning threshold
of the OPS B <Help> This warning
indicates if the receive power
on the receive side of the OPS
B is too low <Condtype> COMB_RX2_PWR_LOW_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcombMeasWng 7 }
pmopsAlmCombTx2PwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx2 High Warning : This OID indicates
that Transmit power or the OPS
B is higher than the warning threshold
of the OPS B <Help> This warning
indicates if the receive power
on the transmit side of the OPS
B is too high <Condtype> COMB_TX2_PWR_HIGH_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcombMeasWng 6 }
pmopsAlmCombTx2PwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx2 Low Warning :This OID indicates
that Transmit power or the OPS
B is lower than the warning threshold
of the OPS B <Help> This warning
indicates if the receive power
on the transmit side of the OPS
B is too low <Condtype> COMB_TX2_PWR_LOW_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcombMeasWng 5 }
pmopsAlmCombRx1PwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx1 High Warning : This OID indicates
that Receive power or the OPS B
is higher than the warning threshold
of the OPS B <Help> This warning
indicates if the receive power
on the receive side of the OPS
B is too high <Condtype> COMB_RX1_PWR_HIGH_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcombMeasWng 4 }
pmopsAlmCombRx1PwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Rx1 Low Warning :This OID indicates
that Receive power or the OPS B
is lower than the warning threshold
of the OPS B <Help> This warning
indicates if the receive power
on the receive side of the OPS
B is too low <Condtype> COMB_RX1_PWR_LOW_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmopsAlmcombMeasWng 3 }
pmopsAlmCombTx1PwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx1 High Warning : This OID indicates
that Transmit power or the OPS
B is higher than the warning threshold
of the OPS B <Help> This warning
indicates if the receive power
on the transmit side of the OPS
B is too high <Condtype> COMB_TX1_PWR_HIGH_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcombMeasWng 2 }
pmopsAlmCombTx1PwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Tx1 Low Warning :This OID indicates
that Transmit power or the OPS
B is lower than the warning threshold
of the OPS B <Help> This warning
indicates if the receive power
on the transmit side of the OPS
B is too low <Condtype> COMB_TX1_PWR_LOW_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmopsAlmcombMeasWng 1 }
--- *****************************************************
--- LEAF for the modInitFailLevel2 article
--- *****************************************************
pmopsAlmmodInitFailLevel2 OBJECT IDENTIFIER ::= { pmopsAlmOtherUrg 70 }
pmopsAlmThreshConfFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Thresh_Conf_Fail : <Condtype>
THRESH_CONF_FAIL <Probcause> other
(1) <Alarmtype> other (1) <Polarity>
(2)
"
::= { pmopsAlmmodInitFailLevel2 7 }
pmopsAlmCalibReadFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Calib_Read_Fail : <Condtype> CALIB_READ_FAIL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmopsAlmmodInitFailLevel2 6 }
pmopsAlmGwIdentFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW_Ident_Fail :This OID indicates
that GW identification has not
been read <Condtype> GW_IDENT_FAIL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmopsAlmmodInitFailLevel2 5 }
pmopsAlmConfReadFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Conf_Read_Fail : <Condtype> CONF_READ_FAIL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmopsAlmmodInitFailLevel2 3 }
pmopsAlmResetHwInitFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Reset_HW_Init_Fail : <Condtype>
RESET_HW_INIT_FAIL <Probcause>
other (1) <Alarmtype> other (1)
<Polarity> (2)
"
::= { pmopsAlmmodInitFailLevel2 2 }
pmopsAlmRegReadFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Reg_Read_Fail : <Condtype> REG_READ_FAIL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmopsAlmmodInitFailLevel2 1 }
--- *****************************************************
--- LEAF for the modInitFailLevel3 article
--- *****************************************************
pmopsAlmmodInitFailLevel3 OBJECT IDENTIFIER ::= { pmopsAlmOtherUrg 71 }
pmopsAlmGwColdBootForced OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW_Cold_Boot_Forced : <Condtype>
GW_COLD_BOOT_FORCED <Probcause>
other (1) <Alarmtype> other (1)
<Polarity> (2)
"
::= { pmopsAlmmodInitFailLevel3 5 }
pmopsAlmOptIdentFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Opt_Ident_Fail : <Condtype> OPT_IDENT_FAIL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmopsAlmmodInitFailLevel3 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synth0 article
--- *****************************************************
pmopsCtrlsynth0 OBJECT IDENTIFIER ::= { pmopsCtrlOther 0 }
pmopsCtrlConfClear OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear Configuration Tables :This
bit clears the configuration tables
from configuration in the flash.
<Help> This control restores
the default configuration of the
module
"
::= { pmopsCtrlsynth0 13 }
pmopsCtrlConfFlash OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write Configuration Tables :This
bit saves the current configuration
of the module as configuration
in the flash. <Help> This control
saves the customer configuration
on the module
"
::= { pmopsCtrlsynth0 9 }
pmopsCtrlConfLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables :When
set this enables loading from flash
configuration1 into the module.
"
::= { pmopsCtrlsynth0 1 }
--- *****************************************************
--- LEAF for the synth4 article
--- *****************************************************
pmopsCtrlsynth4 OBJECT IDENTIFIER ::= { pmopsCtrlOther 4 }
pmopsCtrlCorrelatOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Disable Alarm Correlation :This
OID disables the alarm correlation
in the PM.
"
::= { pmopsCtrlsynth4 2 }
pmopsCtrlCorrelatOn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Enable Alarm Correlation :This
OID enables the alarm correlation
in the PM.
"
::= { pmopsCtrlsynth4 1 }
--- *****************************************************
--- LEAF for the swMgnt article
--- *****************************************************
pmopsCtrlswMgnt OBJECT IDENTIFIER ::= { pmopsCtrlOther 5 }
pmopsCtrlWarmReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Warm Reset :This OID, when
set, causes a warm reset of the
Software. This reset is not traffic
affecting, and the configuration
of the Sofwtare remains unchanged.
<Help> This control initiates
a warm reset of the module.
"
::= { pmopsCtrlswMgnt 3 }
pmopsCtrlColdReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Cold Reset :This OID, when
set, causes a cold reset of the
Software. This reset is traffic
affecting, and the configuration
of Software is reloaded on start-up.
<Help> This control initiates
a cold reset of the module.
"
::= { pmopsCtrlswMgnt 2 }
--- *****************************************************
--- LEAF for the comaSwitchMode article
--- *****************************************************
pmopsCtrlcomaSwitchMode OBJECT-TYPE
SYNTAX PmopsSwitchMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Switch Mode :This OID sets the
switch mode of the OPS A <Help>
This control defines the switch
mode of the OPS A (Manual 1, Manual
2, Auto reversive or auto no reversive)
"
::= { pmopsCtrlComa 16 }
--- *****************************************************
--- LEAF for the combSwitchMode article
--- *****************************************************
pmopsCtrlcombSwitchMode OBJECT-TYPE
SYNTAX PmopsSwitchMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Switch Mode :This OID sets the
switch mode of the OPS B <Help>
This control defines the switch
mode of the OPS B (Manual 1, Manual
2, Auto reversive or auto no reversive)
"
::= { pmopsCtrlComb 17 }
--- *****************************************************
--- LEAF for the comaOosMode article
--- *****************************************************
pmopsCtrlcomaOosMode OBJECT IDENTIFIER ::= { pmopsCtrlComa 18 }
pmopsCtrlComaOosMode OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Out Of Service :This OID sets
the OPS A Out of Service <Help>
This controls defines the service
state of the OPS A
"
::= { pmopsCtrlcomaOosMode 1 }
--- *****************************************************
--- LEAF for the combOosMode article
--- *****************************************************
pmopsCtrlcombOosMode OBJECT IDENTIFIER ::= { pmopsCtrlComb 19 }
pmopsCtrlCombOosMode OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Out Of Service :This OID sets
the OPS B Out of Service <Help>
This controls defines the service
state of the OPS B
"
::= { pmopsCtrlcombOosMode 1 }
--- *****************************************************
--- LEAF for the comaRxPwrSetting1 article
--- *****************************************************
pmopsCtrlcomaRxPwrSetting1 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
RX1 Loss Threshold :This OID sets
the LOS detection threshold on
the RX1 of the OPS A (AV=Power/0.005
+ 32768) (Unit = dBm) <Help>
This control defines the LOS threshold
(in dBm) on the RX1 of the OPS
A
"
::= { pmopsCtrlComa 24 }
--- *****************************************************
--- LEAF for the comaRxPwrSetting2 article
--- *****************************************************
pmopsCtrlcomaRxPwrSetting2 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
RX2 Loss Threshold :This OID sets
the LOS detection threshold on
the RX2 of the OPS A (AV=Power/0.005
+ 32768) (Unit = dBm) <Help>
This control defines the LOS threshold
(in dBm) on the RX2 of the OPS
A
"
::= { pmopsCtrlComa 25 }
--- *****************************************************
--- LEAF for the combRxPwrSetting1 article
--- *****************************************************
pmopsCtrlcombRxPwrSetting1 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
RX1 Loss Threshold :This OID sets
the LOS detection threshold on
the RX1 of the OPS B (AV=Power/0.005
+ 32768) (Unit = dBm) <Help>
This control defines the LOS threshold
(in dBm) on the RX1 of the OPS
B
"
::= { pmopsCtrlComb 26 }
--- *****************************************************
--- LEAF for the combRxPwrSetting2 article
--- *****************************************************
pmopsCtrlcombRxPwrSetting2 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
RX2 Loss Threshold :This OID sets
the LOS detection threshold on
the RX2 of the OPS B (AV=Power/0.005
+ 32768) (Unit = dBm) <Help>
This control defines the LOS threshold
(in dBm) on the RX2 of the OPS
B
"
::= { pmopsCtrlComb 27 }
--- *****************************************************
--- LEAF for the ledTest article
--- *****************************************************
pmopsCtrlledTest OBJECT IDENTIFIER ::= { pmopsCtrlOther 64 }
pmopsCtrlLedOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Leds Off :This OID switches off
all the Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to OFF
"
::= { pmopsCtrlledTest 3 }
pmopsCtrlRedLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Red Leds Test :This OID switches
on all the red Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to red
"
::= { pmopsCtrlledTest 2 }
pmopsCtrlGreenLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Green Leds Test :This OID switches
on all the green Leds as a test
feature. <Help> This control
initiates a test leds turning
all the LEDs to green
"
::= { pmopsCtrlledTest 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the comaTxPower1 article
--- *****************************************************
pmopsMesrcomaTxPower1 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
TX1 Power :This OID gives the
transmit power value of the signal
, read on the coupler output 1
(Power=(AV-32768)*0.005) (Unit
= dBm) <Help> This measure gives
the Transmit optical power on the
TX1 of the OPS A
"
::= { pmopsMesrComa 16 }
--- *****************************************************
--- LEAF for the comaTxPower2 article
--- *****************************************************
pmopsMesrcomaTxPower2 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
TX2 Power :This OID gives the
transmit power value of the signal
, read on the coupler output 2
(Power=(AV-32768)*0.005) (Unit
= dBm) <Help> This measure gives
the Transmit optical power on the
TX2 of the OPS A
"
::= { pmopsMesrComa 17 }
--- *****************************************************
--- LEAF for the comaRxPower1 article
--- *****************************************************
pmopsMesrcomaRxPower1 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX1 Power :This OID gives the
receive power value of the signal
, read on the switch input 1 (Power=(AV-32768)*0.005)
(Unit = dBm) <Help> This measure
gives the Receive optical power
on the RX1 of the OPS A
"
::= { pmopsMesrComa 18 }
--- *****************************************************
--- LEAF for the comaRxPower2 article
--- *****************************************************
pmopsMesrcomaRxPower2 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX2 Power :This OID gives the
receive power value of the signal
, read on the switch input 2 (Power=(AV-32768)*0.005)
(Unit = dBm) <Help> This measure
gives the Receive optical power
on the RX2 of the OPS A
"
::= { pmopsMesrComa 19 }
--- *****************************************************
--- LEAF for the combTxPower1 article
--- *****************************************************
pmopsMesrcombTxPower1 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
TX1 Power :This OID gives the
transmit power value of the signal
, read on the coupler output 1
(Power=(AV-32768)*0.005) (Unit
= dBm) <Help> This measure gives
the Transmit optical power on the
TX1 of the OPS B
"
::= { pmopsMesrComb 24 }
--- *****************************************************
--- LEAF for the combTxPower2 article
--- *****************************************************
pmopsMesrcombTxPower2 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
TX2 Power :This OID gives the
transmit power value of the signal
, read on the coupler output 2
(Power=(AV-32768)*0.005) (Unit
= dBm) <Help> This measure gives
the Transmit optical power on the
TX2 of the OPS B
"
::= { pmopsMesrComb 25 }
--- *****************************************************
--- LEAF for the combRxPower1 article
--- *****************************************************
pmopsMesrcombRxPower1 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX1 Power :This OID gives the
receive power value of the signal
, read on the switch input 1 (Power=(AV-32768)*0.005)
(Unit = dBm) <Help> This measure
gives the Receive optical power
on the RX1 of the OPS B
"
::= { pmopsMesrComb 26 }
--- *****************************************************
--- LEAF for the combRxPower2 article
--- *****************************************************
pmopsMesrcombRxPower2 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
RX2 Power :This OID gives the
receive power value of the signal
, read on the switch input 2 (Power=(AV-32768)*0.005)
(Unit = dBm) <Help> This measure
gives the Receive optical power
on the RX2 of the OPS B
"
::= { pmopsMesrComb 27 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the table Group lsd
--- *****************************************************
pmopsCfgLsd OBJECT IDENTIFIER ::= { pmopsConfig 1 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmopstablecomaLsd OBJECT IDENTIFIER ::= { pmopsCfgLsd 1 }
--- *****************************************************
--- LEAF for the table Group startUp
--- *****************************************************
pmopsCfgStartUp OBJECT IDENTIFIER ::= { pmopsConfig 2 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmopstablecomaStartup OBJECT IDENTIFIER ::= { pmopsCfgStartUp 1 }
pmopsCfgcomaSwitchMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default setting on OPS A switch
:This register configures the
default switch mode on OPS A
"
::= { pmopstablecomaStartup 2 }
pmopsCfgcomaRxPwrSetting1 OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default setting on OPS A Rx Pwr
1 :This register configures the
default RX1 Loss threshold on the
OPS A (Unit = dBm)
"
::= { pmopstablecomaStartup 3 }
pmopsCfgcomaRxPwrSetting2 OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default setting on OPS A Rx Pwr
2 :This register configures the
default RX2 Loss threshold on the
OPS A (Unit = dBm)
"
::= { pmopstablecomaStartup 4 }
pmopsCfgcomaOosMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Setting on OPS A :This
register configures the default
modes on OPS A
"
::= { pmopstablecomaStartup 5 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmopstablecombStartup OBJECT IDENTIFIER ::= { pmopsCfgStartUp 2 }
pmopsCfgcombSwitchMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default setting on OPS B switch
:This register configures the
default switch mode on OPS B
"
::= { pmopstablecombStartup 2 }
pmopsCfgcombRxPwrSetting1 OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default setting on OPS B Rx Pwr
1 :This register configures the
default RX1 Loss threshold on the
OPS B (Unit = dBm)
"
::= { pmopstablecombStartup 3 }
pmopsCfgcombRxPwrSetting2 OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default setting on OPS B Rx Pwr
2 :This register configures the
default RX2 Loss threshold on the
OPS B (Unit = dBm)
"
::= { pmopstablecombStartup 4 }
pmopsCfgcombOosMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Setting on OPS B :This
register configures the default
modes on OPS B
"
::= { pmopstablecombStartup 5 }
--- *****************************************************
--- LEAF for the table Group labels
--- *****************************************************
pmopsCfgLabels OBJECT IDENTIFIER ::= { pmopsConfig 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmopsCfgLabelclientTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmopsCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmopsCfgLabels 1 }
pmopsCfgLabelclientEntry OBJECT-TYPE
SYNTAX PmopsCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmopsCfgLabelclientIndex }
::= { pmopsCfgLabelclientTable 1 }
PmopsCfgLabelclientEntry ::=
SEQUENCE {
pmopsCfgLabelclientIndex
INTEGER,
pmopsCfgLabelclientPortn
DisplayString
}
pmopsCfgLabelclientIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelclient
table
"
::= { pmopsCfgLabelclientEntry 1 }
pmopsCfgLabelclientPortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the Ports :These registers
configures the default initialisation
settings of the labels of the ports.
"
::= { pmopsCfgLabelclientEntry 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmopsCfgLabellineTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmopsCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmopsCfgLabels 2 }
pmopsCfgLabellineEntry OBJECT-TYPE
SYNTAX PmopsCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmopsCfgLabellineIndex }
::= { pmopsCfgLabellineTable 1 }
PmopsCfgLabellineEntry ::=
SEQUENCE {
pmopsCfgLabellineIndex
INTEGER,
pmopsCfgLabellinePortn
DisplayString
}
pmopsCfgLabellineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelline
table
"
::= { pmopsCfgLabellineEntry 1 }
pmopsCfgLabellinePortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the lines :These registers
configures the default initialisation
settings of the labels of the lines.
"
::= { pmopsCfgLabellineEntry 3 }
pmopsCfgWriteConfiguration OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write configuration to module:This OID
writes the complete configuration to the module"
::= { pmopsConfig 257 }
--- *****************************************************
--- TRAP OBJECTS
--- *****************************************************
pmopstrapPortNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last port which generates a trap"
::= { pmopstraps 2 }
pmopstrapLineNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last Line which generates a trap"
::= { pmopstraps 3 }
pmopstrapBoardNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last module which generates a trap"
::= { pmopstraps 4 }
--- *****************************************************
--- ComB TRAPS
--- *****************************************************
pmopsComBTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmopsAlmCombMeasWng, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS B Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pmopsAlmCombMeasWng "on", pmopstrapBoardNumber "$2"}
--&MESG "DDM Warning appears on OPS B of PMOPS in slot $2 ($A)"
DESCRIPTION "Not urgent Line default is activated"
::= { pmopstraps 30 }
pmopsComBTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmopsAlmCombMeasWng, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS B Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOPS B Not Urgent ON"}
--&MATCH { pmopsAlmCombMeasWng "on", pmopstrapBoardNumber "$2"}
--&MESG "DDM Warning disappears on OPS B of PMOPS in slot $2 ($A)"
DESCRIPTION "Not urgent Line default disappeared"
::= { pmopstraps 31 }
pmopsComBTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmopsAlmCombMeasAlm, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS B Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pmopsAlmCombMeasAlm "on", pmopstrapBoardNumber "$2"}
--&MESG "DDM Alarms appears on OPS B of PMOPS in slot $2 ($A)"
DESCRIPTION "Urgent Line default is activated"
::= { pmopstraps 32 }
pmopsComBTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmopsAlmCombMeasAlm, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS B Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOPS B Urgent ON"}
--&MATCH { pmopsAlmCombMeasAlm "on", pmopstrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on OPS B of PMOPS in slot $2 ($A)"
DESCRIPTION "Urgent Line default disappeared"
::= { pmopstraps 33 }
pmopsComBTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmopsAlmCombFailAcc , pmopsAlmCombHwFailAcc, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS B Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmopsAlmCombFailAcc "on", pmopsAlmCombHwFailAcc "*", pmopstrapBoardNumber "$3"}
--&MESG "Critical alarm appears on OPS B of PMOPS in Slot $3 ($A)"
--&FILTNAME "PMOPS B HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmopsAlmCombFailAcc "*", pmopsAlmCombHwFailAcc "on", pmopstrapBoardNumber "$3"}
--&MESG "Critical alarm appears on OPS B of PMOPS in Slot $3 ($A)"
DESCRIPTION "Critical Line default is activated"
::= { pmopstraps 34 }
pmopsComBTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmopsAlmCombFailAcc , pmopsAlmCombHwFailAcc, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS B Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOPS B Fail ON" }
--&MATCH { pmopsAlmCombFailAcc "on", pmopsAlmCombHwFailAcc "*", pmopstrapBoardNumber "$3"}
--&MESG "Critical alarm disappears on OPS B of PMOPS in Slot $3 ($A)"
--&FILTNAME "PMOPS B HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmopsAlmCombFailAcc "*", pmopsAlmCombHwFailAcc "on", pmopstrapBoardNumber "$3"}
--&MESG "Critical alarm disappears on OPS B of PMOPS in Slot $3 ($A)"
DESCRIPTION "Critical Line default disappeared"
::= { pmopstraps 35 }
--- *****************************************************
--- ComA TRAPS
--- *****************************************************
pmopsComATrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmopsAlmComaMeasWng, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS A Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pmopsAlmComaMeasWng "on", pmopstrapBoardNumber "$2"}
--&MESG "DDM Warning appears on OPS A of PMOPS in slot $2 ($A)"
DESCRIPTION "Not urgent client default is activated"
::= { pmopstraps 40 }
pmopsComATrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmopsAlmComaMeasWng, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS A Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOPS A Not Urgent ON"}
--&MATCH { pmopsAlmComaMeasWng "on", pmopstrapBoardNumber "$2"}
--&MESG "DDM Warning disappears on OPS A of PMOPS in slot $2 ($A)"
DESCRIPTION "Not urgent client default disappeared"
::= { pmopstraps 41 }
pmopsComATrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmopsAlmComaMeasAlm, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS A Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pmopsAlmComaMeasAlm "on", pmopstrapBoardNumber "$2"}
--&MESG "DDM Alarms appears on OPS A of PMOPS in slot $2 ($A)"
DESCRIPTION "Urgent client default is activated"
::= { pmopstraps 42 }
pmopsComATrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmopsAlmComaMeasAlm, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS A Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOPS A Urgent ON"}
--&MATCH { pmopsAlmComaMeasAlm "on", pmopstrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on OPS A of PMOPS in slot $2 ($A)"
DESCRIPTION "Urgent client default disappeared"
::= { pmopstraps 43 }
pmopsComATrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmopsAlmComaFailAcc, pmopsAlmComaHwFailAcc, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS A Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmopsAlmComaFailAcc "on", pmopsAlmComaHwFailAcc "*", pmopstrapBoardNumber "$3"}
--&MESG "Critical alarm appears on OPS A of PMOPS in Slot $3 ($A)"
--&FILTNAME "PMOPS A HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmopsAlmComaFailAcc "*", pmopsAlmComaHwFailAcc "on", pmopstrapBoardNumber "$3"}
--&MESG "Critical alarm appears on OPS A of PMOPS in Slot $3 ($A)"
DESCRIPTION "Critical client default is activated"
::= { pmopstraps 44 }
pmopsComATrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmopsAlmComaFailAcc, pmopsAlmComaHwFailAcc, pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS A Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOPS A Fail ON" }
--&MATCH { pmopsAlmComaFailAcc "on", pmopsAlmComaHwFailAcc "*", pmopstrapBoardNumber "$3"}
--&MESG "Critical alarm disappears on OPS A of PMOPS in Slot $3 ($A)"
--&FILTNAME "PMOPS A HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmopsAlmComaFailAcc "*", pmopsAlmComaHwFailAcc "on", pmopstrapBoardNumber "$3"}
--&MESG "Critical alarm disappears on OPS A of PMOPS in Slot $3 ($A)"
DESCRIPTION "Critical client default disappeared"
::= { pmopstraps 45 }
--- *****************************************************
--- HW TRAPS
--- *****************************************************
pmopsPowerTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmopsAlmDefFuseB, pmopsAlmDefFuseA , pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS Fuse A Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmopsAlmDefFuseB "*", pmopsAlmDefFuseA "on", pmopstrapBoardNumber "$3"}
--&MESG "Power Input A Fail on PMOPS in Slot $3 ($A)"
--&FILTNAME "PMOPS Fuse B Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmopsAlmDefFuseB "on", pmopsAlmDefFuseA "*", pmopstrapBoardNumber "$3"}
--&MESG "Power Input B Fail on PMOPS in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default is activated"
::= { pmopstraps 50 }
pmopsPowerTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmopsAlmDefFuseB, pmopsAlmDefFuseA , pmopstrapBoardNumber}
STATUS current
--&FILTNAME "PMOPS Fuse A&B Fail OFF"
--&ACTIONS { log, normal}
--&CLEARS { "PMOPS Fuse A Fail ON", "PMOPS Fuse B Fail ON" }
--&MATCH { pmopsAlmDefFuseB "on", pmopsAlmDefFuseA "on", pmopstrapBoardNumber "$3"}
--&MESG "Power Inputs A and B Present on PMOPS in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default disappeared"
::= { pmopstraps 51 }
END