Observium_CE/mibs/ekinops/EKINOPS-PmOSC-MIB

2330 lines
61 KiB
Plaintext
Raw Permalink Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

-- *****************************************************************
-- EKINOPS-PmOSC.TXT: MIB
--
--MIB Part Number:3MI00110AHAD
--MIB Version:01
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
--
-- *****************************************************************
EKINOPS-PmOSC-MIB DEFINITIONS ::= BEGIN
IMPORTS
ekinops,
EkiState,
EkiOnOff,
EkiMode,
EkiProtocol,
EkiApiState,
EkiSynchroMode,
EkiMeasureType
FROM EKINOPS-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32,
Counter32,
IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString
FROM SNMPv2-TC;
modulePmOSC MODULE-IDENTITY
LAST-UPDATED "201605230000Z"
ORGANIZATION "Ekinops"
CONTACT-INFO
"Ekinops
3, rue Blaise Pascal
F-22300 Lannion / FRANCE
Tel : +33 (0)2 96 05 00 30
Fax : +33 (0)2 96 48 62 39
E-mail: support@ekinops.net"
DESCRIPTION
"MIB for the Ekinops PmOsc hardware."
REVISION "200607030000Z"
DESCRIPTION
"Initial Version."
REVISION "200705210000Z"
DESCRIPTION
"OOS functionality insertion."
REVISION "200706280000Z"
DESCRIPTION
"°C change to C."
REVISION "200711210000Z"
DESCRIPTION
"Update Ekinops address, Helps on objects, Ports labels "
REVISION "200905180000Z"
DESCRIPTION
"CondType parameters insertion"
REVISION "201002250000Z"
DESCRIPTION
"Probcause,AlarmType - NMS"
REVISION "201011040000Z"
DESCRIPTION
"Formulas in comments"
REVISION "201207040000Z"
DESCRIPTION
"Minor cosmetic updates"
REVISION "201403270000Z"
DESCRIPTION
"Probcause,AlarmType - NMS completion"
REVISION "201412110000Z"
DESCRIPTION
"Labels cosmetic updates"
REVISION "201605230000Z"
DESCRIPTION
"New AlarmType synthesisAlarm (12)"
::= { ekinops 14 }
--- *****************************************************
--- LEAF LEVEL 2
--- *****************************************************
pmoscalarms OBJECT IDENTIFIER ::= { modulePmOSC 2 }
pmoscAlmOther OBJECT IDENTIFIER ::= { pmoscalarms 1 }
pmoscAlmOtherNurg OBJECT IDENTIFIER ::= { pmoscAlmOther 1 }
pmoscAlmOtherUrg OBJECT IDENTIFIER ::= { pmoscAlmOther 2 }
pmoscAlmOtherCrit OBJECT IDENTIFIER ::= { pmoscAlmOther 3 }
pmoscAlmClient OBJECT IDENTIFIER ::= { pmoscalarms 2 }
pmoscAlmClientNurg OBJECT IDENTIFIER ::= { pmoscAlmClient 1 }
pmoscAlmClientUrg OBJECT IDENTIFIER ::= { pmoscAlmClient 2 }
pmoscAlmClientCrit OBJECT IDENTIFIER ::= { pmoscAlmClient 3 }
pmoscAlmLine OBJECT IDENTIFIER ::= { pmoscalarms 3 }
pmoscAlmLineNurg OBJECT IDENTIFIER ::= { pmoscAlmLine 1 }
pmoscAlmLineUrg OBJECT IDENTIFIER ::= { pmoscAlmLine 2 }
pmoscAlmLineCrit OBJECT IDENTIFIER ::= { pmoscAlmLine 3 }
pmoscmeasures OBJECT IDENTIFIER ::= { modulePmOSC 3 }
pmoscMesrOther OBJECT IDENTIFIER ::= { pmoscmeasures 1 }
pmoscMesrClient OBJECT IDENTIFIER ::= { pmoscmeasures 2 }
pmoscMesrLine OBJECT IDENTIFIER ::= { pmoscmeasures 3 }
pmosccontrolsWrite OBJECT IDENTIFIER ::= { modulePmOSC 6 }
pmoscCtrlOther OBJECT IDENTIFIER ::= { pmosccontrolsWrite 1 }
pmoscCtrlClient OBJECT IDENTIFIER ::= { pmosccontrolsWrite 2 }
pmoscCtrlLine OBJECT IDENTIFIER ::= { pmosccontrolsWrite 3 }
pmoscri OBJECT IDENTIFIER ::= { modulePmOSC 7 }
pmoscConfig OBJECT IDENTIFIER ::= { modulePmOSC 9 }
pmosctraps OBJECT IDENTIFIER ::= { modulePmOSC 10 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pmoscRinvReloadInventory OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reload the inventory: This OID triggers an
inventory reload."
::= { pmoscri 2 }
pmoscRinvHwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module platform description: This OID contains the
description of the Module."
::= { pmoscri 4 }
pmoscRinvSwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW platform description: This OID contains the
description of the Software platform."
::= { pmoscri 5 }
pmoscRinvPortASFP OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the SFP: This OID contains the inventory for the Port A SFP"
::= { pmoscri 6 }
pmoscRinvPortBSFP OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the SFP: This OID contains the inventory for the Port B SFP"
::= { pmoscri 7 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synthAlm0 article
--- *****************************************************
pmoscAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmoscAlmOtherCrit 0 }
pmoscAlmDefFuseB OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse B Fail :This OID indicates
that the fuse of the power input
B is in fail condition <Help>
Status of the Fuse B <Condtype>
DEF_FUSE_B <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmsynthAlm0 16 }
pmoscAlmDefFuseA OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse A Fail :This OID indicates
that the fuse of the power input
A is in fail condition <Help>
Status of the Fuse A <Condtype>
DEF_FUSE_A <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmsynthAlm0 15 }
pmoscAlmModuleGlobFailure OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Failure :This OID is set
on detection of a failure originating
from the PM <Condtype> MODULE_GLOB_FAILURE
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoscAlmsynthAlm0 9 }
--- *****************************************************
--- LEAF for the synthAlm7 article
--- *****************************************************
pmoscAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmoscAlmLineCrit 7 }
pmoscAlmPortbFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Port B Failure :This OID indicates
a failure on the port B <Condtype>
PORTB_FAIL <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoscAlmsynthAlm7 12 }
pmoscAlmPortbDdmAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm DDM On SFP B :This OID indicates
an alarm is present coming out
of optical interface DDM on port
B <Help> This alarm indicates
if a DDM Alarm has been detected
on the port B transceiver <Condtype>
PORTB_DDM_ALM <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoscAlmsynthAlm7 10 }
pmoscAlmPortbDdmWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning DDM On SFP B :This OID
indicates a warning is present
coming out of optical interface
DDM on port B <Help> This alarm
indicates if a DDM Warning has
been detected on the port B transceiver
<Condtype> PORTB_DDM_WARNING <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoscAlmsynthAlm7 9 }
pmoscAlmPortbLocalOos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B In Service :This OID indicates
that the Port B is In Service (1)
of Out or Service (2) <Help>
This status indicates if the port
B is in service <Condtype> PORTB_LOCAL_OOS
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmoscAlmsynthAlm7 6 }
pmoscAlmPortbLsd OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Laser Shutdown :This OID
indicates the optical output power
is off on port B <Help> This
status indicates if the port B
transceiver laser is ON or OFF
<Condtype> PORTB_LSD <Probcause>
informationalStatus(1000) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoscAlmsynthAlm7 5 }
pmoscAlmPortbHwFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Port B HW Failure :This OID indicates
a hardware failure on the port
B <Condtype> PORTB_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoscAlmsynthAlm7 4 }
pmoscAlmPortbDdmAbsent OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
DDM Supported On SFP B :This OID
indicates that the SFP module B
does not support Digital Diagnostic
Monitoring Functions <Help> This
status indicates if the porr B
transceiver includes the DDM feature
<Condtype> PORTB_DDM_ABSENT <Probcause>
equipmentMalfunction (16) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoscAlmsynthAlm7 2 }
pmoscAlmPortbSfpAbsent OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Absent :This OID indicates
that the SFP module B is not present.
<Help> This alarm indicates if
the port B transceiver is present.
<Condtype> PORTB_SFP_ABSENT <Probcause>
inputOutputDeviceError (24) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
<Event> ObjectCDINV
"
::= { pmoscAlmsynthAlm7 1 }
--- *****************************************************
--- LEAF for the synthAlm8 article
--- *****************************************************
pmoscAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmoscAlmClientCrit 8 }
pmoscAlmPortaFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Port A Failure :This OID indicates
a failure on the port A <Condtype>
PORTA_FAIL <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoscAlmsynthAlm8 12 }
pmoscAlmPortaDdmAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm DDM On SFP A :This OID indicates
an alarm is present coming out
of optical interface DDM on port
A <Help> This alarm indicates
if a DDM Alarm has been detected
on the port A transceiver <Condtype>
PORTA_DDM_ALM <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoscAlmsynthAlm8 10 }
pmoscAlmPortaDdmWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning DDM On SFP A :This OID
indicates a warning is present
coming out of optical interface
DDM on port A <Help> This alarm
indicates if a DDM Warning has
been detected on the port A transceiver
<Condtype> PORTA_DDM_WARNING <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoscAlmsynthAlm8 9 }
pmoscAlmPortaLocalOos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A In Service :This OID indicates
that the Port A is In Service (1)
of Out or Service (2) <Help>
This status indicates if the port
A is in service <Condtype> PORTA_LOCAL_OOS
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmoscAlmsynthAlm8 6 }
pmoscAlmPortaLsd OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Laser Shutdown :This OID
indicates the optical output power
is off on port A <Help> This
status indicates if the port A
transceiver laser is ON or OFF
<Condtype> PORTA_LSD <Probcause>
informationalStatus(1000) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoscAlmsynthAlm8 5 }
pmoscAlmPortaHwFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Port A HW Failure :This OID indicates
a hardware failure on the port
A <Condtype> PORTA_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoscAlmsynthAlm8 4 }
pmoscAlmPortaDdmAbsent OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
DDM Supported On SFP A :This OID
indicates that the SFP module A
does not support Digital Diagnostic
Monitoring Functions <Help> This
status indicates if the port A
transceiver includes the DDM feature
<Condtype> PORTA_DDM_ABSENT <Probcause>
equipmentMalfunction (16) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoscAlmsynthAlm8 2 }
pmoscAlmPortaSfpAbsent OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Absent :This OID indicates
that the SFP module A is not present.
<Help> This alarm indicates if
the port A transceiver is present.
<Condtype> PORTA_SFP_ABSENT <Probcause>
inputOutputDeviceError (24) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
<Event> ObjectCDINV
"
::= { pmoscAlmsynthAlm8 1 }
--- *****************************************************
--- LEAF for the portaAccessioAlm article
--- *****************************************************
pmoscAlmportaAccessioAlm OBJECT IDENTIFIER ::= { pmoscAlmClientCrit 16 }
pmoscAlmPortaLos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Loss Of Optical Signal On SFP
A :This OID indicates that no
signal is present on the SFP A
<Help> This alarm indicates if
an optical signal is detected on
the port A transceiver input <Condtype>
PORTA_LOS <Probcause> receiveFailure
(41) <Alarmtype> physicalViolation
(9) <Polarity> (2)
"
::= { pmoscAlmportaAccessioAlm 4 }
pmoscAlmPortaLasFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Tx Failed :This OID indicates
that the transmitter fails for
the SFP plugged into the port
A (this alarm reports the transmitter
failure alarm generated by the
SFPs) <Help> This alarm indicates
if the laser of the port A transceiver
is in fail condition <Condtype>
PORTA_LAS_FAIL <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportaAccessioAlm 1 }
--- *****************************************************
--- LEAF for the portaSfpAlmDdm article
--- *****************************************************
pmoscAlmportaSfpAlmDdm OBJECT IDENTIFIER ::= { pmoscAlmClientUrg 18 }
pmoscAlmPortaRxPwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Rx Power High :Alarm indicating
that the SFP input power of port
A is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTA_RX_PWR_HIGH_ALA
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoscAlmportaSfpAlmDdm 16 }
pmoscAlmPortaRxPwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Rx Power Low :Alarm indicating
that the SFP input power of port
A is lower than the threshold value
written in the SFP EEPROM <Condtype>
PORTA_RX_PWR_LOW_ALA <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoscAlmportaSfpAlmDdm 15 }
pmoscAlmPortaTempHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Temp High :Alarm indicating
that the SFP temperature of port
A is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTA_TEMP_HIGH_ALA
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportaSfpAlmDdm 8 }
pmoscAlmPortaTempLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Temp Low :Alarm indicating
that the SFP temperature of port
A is lower than the threshold value
written in the SFP EEPROM <Condtype>
PORTA_TEMP_LOW_ALA <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoscAlmportaSfpAlmDdm 7 }
pmoscAlmPortaTxBiasHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Bias High :Alarm indicating
that the SFP laser bias current
of port A is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTA_TX_BIAS_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportaSfpAlmDdm 4 }
pmoscAlmPortaTxBiasLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Bias Low :Alarm indicating
that the SFP laser bias current
of port A is lower than the threshold
value written in the SFP EEPROM
<Condtype> PORTA_TX_BIAS_LOW_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportaSfpAlmDdm 3 }
pmoscAlmPortaTxPwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Tx Power High :Alarm indicating
that the SFP output power of port
A is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTA_TX_PWR_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportaSfpAlmDdm 2 }
pmoscAlmPortaTxPwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Tx Power Low :Alarm indicating
that the SFP output power of port
A is lower than the threshold value
written in the SFP EEPROM <Condtype>
PORTA_TX_PWR_LOW_ALA <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoscAlmportaSfpAlmDdm 1 }
--- *****************************************************
--- LEAF for the portaSfpWarnDdm article
--- *****************************************************
pmoscAlmportaSfpWarnDdm OBJECT IDENTIFIER ::= { pmoscAlmClientNurg 20 }
pmoscAlmPortaRxPwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Rx Power High Warning :Warning
indicating that the SFP input power
of port A is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTA_RX_PWR_HIGH_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoscAlmportaSfpWarnDdm 16 }
pmoscAlmPortaRxPwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Rx Power Low Warning :Warning
indicating that the SFP input power
of port A is lower than the threshold
value written in the SFP EEPROM
<Condtype> PORTA_RX_PWR_LOW_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoscAlmportaSfpWarnDdm 15 }
pmoscAlmPortaTempHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Temp High Warning :Warning
indicating that the SFP temperature
of port A is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTA_TEMP_HIGH_WNG
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportaSfpWarnDdm 8 }
pmoscAlmPortaTempLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Temp Low Warning :Warning
indicating that the SFP temperature
of port A is lower than the threshold
value written in the SFP EEPROM
<Condtype> PORTA_TEMP_LOW_WNG <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoscAlmportaSfpWarnDdm 7 }
pmoscAlmPortaTxBiasHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Bias High Warning :Warning
indicating that the SFP laser bias
current of port A is higher than
the threshold value written in
the SFP EEPROM <Condtype> PORTA_TX_BIAS_HIGH_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportaSfpWarnDdm 4 }
pmoscAlmPortaTxBiasLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Bias Low Warning :Warning
indicating that the SFP laser bias
current of port A is lower than
the threshold value written in
the SFP EEPROM <Condtype> PORTA_TX_BIAS_LOW_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportaSfpWarnDdm 3 }
pmoscAlmPortaTxPwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Tx Power High Warning :Warning
indicating that the SFP output
power of port A is higher than
the threshold value written in
the SFP EEPROM <Condtype> PORTA_TX_PWR_HIGH_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportaSfpWarnDdm 2 }
pmoscAlmPortaTxPwLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Tx Power Low Warning :Warning
indicating that the SFP output
power of port A is lower than
the threshold value written in
the SFP EEPROM <Condtype> PORTA_TX_PW_LOW_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportaSfpWarnDdm 1 }
--- *****************************************************
--- LEAF for the portbAccessioAlm article
--- *****************************************************
pmoscAlmportbAccessioAlm OBJECT IDENTIFIER ::= { pmoscAlmLineCrit 24 }
pmoscAlmPortbLos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Loss Of Optical Signal On SFP
B :This OID indicates that no
signal is present on the SFP B
<Help> This alarm indicates if
an optical signal is detected on
the port B transceiver input <Condtype>
PORTB_LOS <Probcause> receiveFailure
(41) <Alarmtype> physicalViolation
(9) <Polarity> (2)
"
::= { pmoscAlmportbAccessioAlm 4 }
pmoscAlmPortbLasFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Tx Failed :This OID indicates
that the transmitter fails for
the SFP plugged into the port
A (this alarm reports the transmitter
failure alarm generated by the
SFPs) <Help> This alarm indicates
if the laser of the port B transceiver
is in fail condition <Condtype>
PORTB_LAS_FAIL <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportbAccessioAlm 1 }
--- *****************************************************
--- LEAF for the portbSfpAlmDdm article
--- *****************************************************
pmoscAlmportbSfpAlmDdm OBJECT IDENTIFIER ::= { pmoscAlmLineUrg 26 }
pmoscAlmPortbRxPwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Rx Power High :Alarm indicating
that the SFP input power of port
B is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTB_RX_PWR_HIGH_ALA
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoscAlmportbSfpAlmDdm 16 }
pmoscAlmPortbRxPwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Rx Power Low :Alarm indicating
that the SFP input power of port
B is lower than the threshold value
written in the SFP EEPROM <Condtype>
PORTB_RX_PWR_LOW_ALA <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoscAlmportbSfpAlmDdm 15 }
pmoscAlmPortbTempHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Temp High :Alarm indicating
that the SFP temperature of port
B is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTB_TEMP_HIGH_ALA
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportbSfpAlmDdm 8 }
pmoscAlmPortbTempLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Temp Low :Alarm indicating
that the SFP temperature of port
B is lower than the threshold value
written in the SFP EEPROM <Condtype>
PORTB_TEMP_LOW_ALA <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoscAlmportbSfpAlmDdm 7 }
pmoscAlmPortbTxBiasHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Bias High :Alarm indicating
that the SFP laser bias current
of port B is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTB_TX_BIAS_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportbSfpAlmDdm 4 }
pmoscAlmPortbTxBiasLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Bias Low :Alarm indicating
that the SFP laser bias current
of port B is lower than the threshold
value written in the SFP EEPROM
<Condtype> PORTB_TX_BIAS_LOW_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportbSfpAlmDdm 3 }
pmoscAlmPortbTxPwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Tx Power High :Alarm indicating
that the SFP output power of port
B is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTB_TX_PWR_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportbSfpAlmDdm 2 }
pmoscAlmPortbTxPwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Tx Power Low :Alarm indicating
that the SFP output power of port
B is lower than the threshold value
written in the SFP EEPROM <Condtype>
PORTB_TX_PWR_LOW_ALA <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoscAlmportbSfpAlmDdm 1 }
--- *****************************************************
--- LEAF for the portbSfpWarnDdm article
--- *****************************************************
pmoscAlmportbSfpWarnDdm OBJECT IDENTIFIER ::= { pmoscAlmLineNurg 28 }
pmoscAlmPortbRxPwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Rx Power High Warning :Warning
indicating that the SFP input power
of port B is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTB_RX_PWR_HIGH_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoscAlmportbSfpWarnDdm 16 }
pmoscAlmPortbRxPwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Rx Power Low Warning :Warning
indicating that the SFP input power
of port B is lower than the threshold
value written in the SFP EEPROM
<Condtype> PORTB_RX_PWR_LOW_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoscAlmportbSfpWarnDdm 15 }
pmoscAlmPortbTempHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Temp High Warning :Warning
indicating that the SFP temperature
of port B is higher than the threshold
value written in the SFP EEPROM
<Condtype> PORTB_TEMP_HIGH_WNG
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportbSfpWarnDdm 8 }
pmoscAlmPortbTempLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Temp Low Warning :Warning
indicating that the SFP temperature
of port B is lower than the threshold
value written in the SFP EEPROM
<Condtype> PORTB_TEMP_LOW_WNG <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoscAlmportbSfpWarnDdm 7 }
pmoscAlmPortbTxBiasHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Bias High Warning :Warning
indicating that the SFP laser bias
current of port B is higher than
the threshold value written in
the SFP EEPROM <Condtype> PORTB_TX_BIAS_HIGH_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportbSfpWarnDdm 4 }
pmoscAlmPortbTxBiasLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Bias Low Warning :Warning
indicating that the SFP laser bias
current of port B is lower than
the threshold value written in
the SFP EEPROM <Condtype> PORTB_TX_BIAS_LOW_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportbSfpWarnDdm 3 }
pmoscAlmPortbTxPwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Tx Power High Warning :Warning
indicating that the SFP output
power of port B is higher than
the threshold value written in
the SFP EEPROM <Condtype> PORTB_TX_PWR_HIGH_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportbSfpWarnDdm 2 }
pmoscAlmPortbTxPwLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Tx Power Low Warning :Warning
indicating that the SFP output
power of port B is lower than
the threshold value written in
the SFP EEPROM <Condtype> PORTB_TX_PW_LOW_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoscAlmportbSfpWarnDdm 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synth0 article
--- *****************************************************
pmoscCtrlsynth0 OBJECT IDENTIFIER ::= { pmoscCtrlOther 0 }
pmoscCtrlConfClear OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear Configuration Tables :This
bit clears the configuration tables
from configuration in the flash.
<Help> This control restores
the default configuration of the
module
"
::= { pmoscCtrlsynth0 13 }
pmoscCtrlConfFlash OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write Configuration Tables :This
bit saves the current configuration
of the module as configuration
in the flash. <Help> This control
saves the customer configuration
on the module
"
::= { pmoscCtrlsynth0 9 }
pmoscCtrlConfLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables :When
set this enables loading from flash
configuration1 into the module.
"
::= { pmoscCtrlsynth0 1 }
--- *****************************************************
--- LEAF for the synth4 article
--- *****************************************************
pmoscCtrlsynth4 OBJECT IDENTIFIER ::= { pmoscCtrlOther 4 }
pmoscCtrlCorrelatOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Disable Alarm Correlation :This
OID disables the alarm correlation
in the PM.
"
::= { pmoscCtrlsynth4 2 }
pmoscCtrlCorrelatOn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Enable Alarm Correlation :This
OID enables the alarm correlation
in the PM.
"
::= { pmoscCtrlsynth4 1 }
--- *****************************************************
--- LEAF for the swMgnt article
--- *****************************************************
pmoscCtrlswMgnt OBJECT IDENTIFIER ::= { pmoscCtrlOther 5 }
pmoscCtrlWarmReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Software Warm Reset :This OID,
when set, causes a warm reset of
the Software. This reset is not
traffic affecting, and the configuration
of the Sofwtare remains unchanged.
<Help> This control initiates
a warm reset of the module.
"
::= { pmoscCtrlswMgnt 3 }
pmoscCtrlColdReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Software Cold Reset :This OID,
when set, causes a cold reset of
the Software. This reset is traffic
affecting, and the configuration
of Software is reloaded on start-up.
<Help> This control initiates
a cold reset of the module.
"
::= { pmoscCtrlswMgnt 2 }
--- *****************************************************
--- LEAF for the portaSfpOnoff article
--- *****************************************************
pmoscCtrlportaSfpOnoff OBJECT IDENTIFIER ::= { pmoscCtrlClient 16 }
pmoscCtrlPortaSfpOnoff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
SFP A Optical Laser Shutdown :This
OID switches off the SFP A <Help>
This control defines the laser
state of the port A transceiver
"
::= { pmoscCtrlportaSfpOnoff 1 }
--- *****************************************************
--- LEAF for the portaOosMode article
--- *****************************************************
pmoscCtrlportaOosMode OBJECT IDENTIFIER ::= { pmoscCtrlClient 17 }
pmoscCtrlPortaOosMode OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
SFP A Port Out Of Service :This
OID sets the Port A Out Of Service
<Help> This controls defines
the service state of the port
A
"
::= { pmoscCtrlportaOosMode 1 }
--- *****************************************************
--- LEAF for the portbSfpOnoff article
--- *****************************************************
pmoscCtrlportbSfpOnoff OBJECT IDENTIFIER ::= { pmoscCtrlLine 24 }
pmoscCtrlPortbSfpOnoff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
SFP B Optical Laser Shutdown :This
OID switches off the SFP B <Help>
This control defines the laser
state of the port B transceiver
"
::= { pmoscCtrlportbSfpOnoff 1 }
--- *****************************************************
--- LEAF for the portbOosMode article
--- *****************************************************
pmoscCtrlportbOosMode OBJECT IDENTIFIER ::= { pmoscCtrlLine 25 }
pmoscCtrlPortbOosMode OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
SFP B Port Out Of Service :This
OID sets the Port B Out Of Service
<Help> This controls defines
the service state of the port
B
"
::= { pmoscCtrlportbOosMode 1 }
--- *****************************************************
--- LEAF for the ledTest article
--- *****************************************************
pmoscCtrlledTest OBJECT IDENTIFIER ::= { pmoscCtrlOther 64 }
pmoscCtrlLedOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Leds Off :This OID switches off
all the Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to OFF
"
::= { pmoscCtrlledTest 3 }
pmoscCtrlRedLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Red Leds Test :This OID switches
on all the red Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to red
"
::= { pmoscCtrlledTest 2 }
pmoscCtrlGreenLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Green Leds Test :This OID switches
on all the green Leds as a test
feature. <Help> This control
initiates a test leds turning
all the LEDs to green
"
::= { pmoscCtrlledTest 1 }
--- *****************************************************
--- LEAF for the moduleOosMode article
--- *****************************************************
pmoscCtrlmoduleOosMode OBJECT IDENTIFIER ::= { pmoscCtrlOther 65 }
pmoscCtrlModuleOosMode OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Out Of Service :This OID sets
the PM Out Of Service <Help>
This control defines the service
state of the complete module
"
::= { pmoscCtrlmoduleOosMode 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the portaTemperature article
--- *****************************************************
pmoscMesrportaTemperature OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Temperature :This OID gives
the temperature of the SFP A, read
from the DDM (Digital Diagnostic
Monitoring) (Temperature = AV/256)
(Unit = C) <Help> This measure
gives the temperature of the port
A transceiver
"
::= { pmoscMesrClient 16 }
--- *****************************************************
--- LEAF for the portaVolt article
--- *****************************************************
pmoscMesrportaVolt OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Power Supply :This OID gives
the voltage of the SFP A, read
from the DDM (Digital Diagnostic
Monitoring) (Voltage = AV/10000)
(Unit = V) <Help> This measure
gives the 3V3 voltage of the port
A transceiver
"
::= { pmoscMesrClient 17 }
--- *****************************************************
--- LEAF for the portaTxBias article
--- *****************************************************
pmoscMesrportaTxBias OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Laser Bias :This OID gives
the bias value of the SFP A, read
from the DDM (Digital Diagnostic
Monitoring) (Bias = AV/500) (Unit
= mA) <Help> This measure gives
the bias of the port A transceiver
"
::= { pmoscMesrClient 18 }
--- *****************************************************
--- LEAF for the portaTxPower article
--- *****************************************************
pmoscMesrportaTxPower OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Tx Power :This OID gives
the transmit power value of the
SFP A, read from the DDM (Digital
Diagnostic Monitoring) (Power
= 10*log(AV)-40) (Unit = dBm)
<Help> This measure gives the
Tx optical power of the port A
transceiver
"
::= { pmoscMesrClient 19 }
--- *****************************************************
--- LEAF for the portaRxPower article
--- *****************************************************
pmoscMesrportaRxPower OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP A Rx Power :This OID gives
the receive power value of the
SFP A, read from the DDM (Digital
Diagnostic Monitoring) (Power =
10*log(AV)-40) (Unit = dBm) <Help>
This measure gives the Rx optical
power of the port A transceiver
"
::= { pmoscMesrClient 20 }
--- *****************************************************
--- LEAF for the portbTemperature article
--- *****************************************************
pmoscMesrportbTemperature OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Temperature :This OID gives
the temperature of the SFP B, read
from the DDM (Digital Diagnostic
Monitoring) (Temperature = AV/256)
(Unit = C) <Help> This measure
gives the temperature of the port
B transceiver
"
::= { pmoscMesrLine 24 }
--- *****************************************************
--- LEAF for the portbVolt article
--- *****************************************************
pmoscMesrportbVolt OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Power Supply :This OID gives
the voltage of the SFP B, read
from the DDM (Digital Diagnostic
Monitoring) (Voltage = AV/10000)
(Unit = V) <Help> This measure
gives the 3V3 voltage of the port
B transceiver
"
::= { pmoscMesrLine 25 }
--- *****************************************************
--- LEAF for the portbTxBias article
--- *****************************************************
pmoscMesrportbTxBias OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Laser Bias :This OID gives
the bias value of the SFP B, read
from the DDM (Digital Diagnostic
Monitoring) (Bias = AV/500) (Unit
= mA) <Help> This measure gives
the bias of the port B transceiver
"
::= { pmoscMesrLine 26 }
--- *****************************************************
--- LEAF for the portbTxPower article
--- *****************************************************
pmoscMesrportbTxPower OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Tx Power :This OID gives
the transmit power value of the
SFP B, read from the DDM (Digital
Diagnostic Monitoring) (Power
= 10*log(AV)-40) (Unit = dBm)
<Help> This measure gives the
Tx optical power of the port B
transceiver
"
::= { pmoscMesrLine 27 }
--- *****************************************************
--- LEAF for the portbRxPower article
--- *****************************************************
pmoscMesrportbRxPower OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SFP B Rx Power :This OID gives
the receive power value of the
SFP B, read from the DDM (Digital
Diagnostic Monitoring) (Power =
10*log(AV)-40) (Unit = dBm) <Help>
This measure gives the Rx optical
power of the port B transceiver
"
::= { pmoscMesrLine 28 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the table Group lsd
--- *****************************************************
pmoscCfgLsd OBJECT IDENTIFIER ::= { pmoscConfig 1 }
--- *****************************************************
--- LEAF for the table Group startUp
--- *****************************************************
pmoscCfgStartUp OBJECT IDENTIFIER ::= { pmoscConfig 2 }
--- *****************************************************
--- LEAF for the table 2111
--- *****************************************************
pmosctableclientStartup OBJECT IDENTIFIER ::= { pmoscCfgStartUp 1 }
pmoscCfgportaSfpCtrl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Port A :This
register configures the default
initialisation settings on port
A.
"
::= { pmosctableclientStartup 2 }
pmoscCfgportaOosMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Port A :This
register configures the default
initialisation settings on port
A.
"
::= { pmosctableclientStartup 3 }
--- *****************************************************
--- LEAF for the table 2191
--- *****************************************************
pmosctablelineStartup OBJECT IDENTIFIER ::= { pmoscCfgStartUp 2 }
pmoscCfgportbSfpCtrl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Port B :This
register configures the default
initialisation settings on port
B.
"
::= { pmosctablelineStartup 2 }
pmoscCfgportbOosMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Port B :This
register configures the default
initialisation settings on port
B.
"
::= { pmosctablelineStartup 3 }
--- *****************************************************
--- LEAF for the table Group labels
--- *****************************************************
pmoscCfgLabels OBJECT IDENTIFIER ::= { pmoscConfig 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmoscCfgLabelclientTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmoscCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmoscCfgLabels 1 }
pmoscCfgLabelclientEntry OBJECT-TYPE
SYNTAX PmoscCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmoscCfgLabelclientIndex }
::= { pmoscCfgLabelclientTable 1 }
PmoscCfgLabelclientEntry ::=
SEQUENCE {
pmoscCfgLabelclientIndex
INTEGER,
pmoscCfgLabelclientPortn
DisplayString
}
pmoscCfgLabelclientIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelclient
table
"
::= { pmoscCfgLabelclientEntry 1 }
pmoscCfgLabelclientPortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the Ports :These registers
configures the default initialisation
settings of the labels of the ports.
"
::= { pmoscCfgLabelclientEntry 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmoscCfgLabellineTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmoscCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmoscCfgLabels 2 }
pmoscCfgLabellineEntry OBJECT-TYPE
SYNTAX PmoscCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmoscCfgLabellineIndex }
::= { pmoscCfgLabellineTable 1 }
PmoscCfgLabellineEntry ::=
SEQUENCE {
pmoscCfgLabellineIndex
INTEGER,
pmoscCfgLabellinePortn
DisplayString
}
pmoscCfgLabellineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelline
table
"
::= { pmoscCfgLabellineEntry 1 }
pmoscCfgLabellinePortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the lines :These registers
configures the default initialisation
settings of the labels of the lines.
"
::= { pmoscCfgLabellineEntry 3 }
pmoscCfgWriteConfiguration OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write configuration to module:This OID
writes the complete configuration to the module"
::= { pmoscConfig 257 }
--- *****************************************************
--- TRAP OBJECTS
--- *****************************************************
pmosctrapBoardNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last module which generates a trap"
::= { pmosctraps 4 }
--- *****************************************************
--- GLOBAL TRAPS
--- *****************************************************
pmoscPortaTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortaDdmWarning, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port A Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pmoscAlmPortaDdmWarning "on", pmosctrapBoardNumber "$2"}
--&MESG "DDM Warning appears on Port A of PMOSC in slot $2 ($A)"
DESCRIPTION "Not urgent Port A default is activated"
::= { pmosctraps 30 }
pmoscPortaTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortaDdmWarning, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port A Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOSC Port A Not Urgent ON"}
--&MATCH { pmoscAlmPortaDdmWarning "on", pmosctrapBoardNumber "$2"}
--&MESG "DDM Warning disappears on Port A of PMOSC in slot $2 ($A)"
DESCRIPTION "Not urgent Port A default disappeared"
::= { pmosctraps 31 }
pmoscPortaTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortaDdmAlm, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port A Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pmoscAlmPortaDdmAlm "on", pmosctrapBoardNumber "$2"}
--&MESG "DDM Alarms appears on Port A of PMOSC in slot $2 ($A)"
DESCRIPTION "Urgent Port A default is activated"
::= { pmosctraps 32 }
pmoscPortaTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortaDdmAlm, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port A Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOSC Port A Urgent ON"}
--&MATCH { pmoscAlmPortaDdmAlm "on", pmosctrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on Port A of PMOSC in slot $2 ($A)"
DESCRIPTION "Urgent Port A default disappeared"
::= { pmosctraps 33 }
pmoscPortaTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortaFail, pmoscAlmPortaHwFail, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port A Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmoscAlmPortaFail "on", pmoscAlmPortaHwFail "*", pmosctrapBoardNumber "$3"}
--&MESG "Port A Down on PMOSC in Slot $3 ($A)"
--&FILTNAME "PMOSC Port A HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoscAlmPortaFail "*", pmoscAlmPortaHwFail "on", pmosctrapBoardNumber "$3"}
--&MESG "Port A Down on PMOSC in Slot $3 ($A)"
DESCRIPTION "Critical Port A default is activated"
::= { pmosctraps 34 }
pmoscPortaTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortaFail, pmoscAlmPortaHwFail, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port A Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOSC Port A Fail ON" }
--&MATCH { pmoscAlmPortaFail "on", pmoscAlmPortaHwFail "*", pmosctrapBoardNumber "$3"}
--&MESG "Port A Up on PMOSC in Slot $3 ($A)"
--&FILTNAME "PMOSC Port A HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoscAlmPortaFail "*", pmoscAlmPortaHwFail "on", pmosctrapBoardNumber "$3"}
--&MESG "Port A Up on PMOSC in Slot $3 ($A)"
DESCRIPTION "Critical Port A default disappeared"
::= { pmosctraps 35 }
--- *****************************************************
--- PORTS TRAPS
--- *****************************************************
pmoscPortbNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortbDdmWarning, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port B Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pmoscAlmPortbDdmWarning "on", pmosctrapBoardNumber "$2"}
--&MESG "DDM Warning appears on Port B of PMOSC in slot $2 ($A)"
DESCRIPTION "Not urgent Port B default is activated"
::= { pmosctraps 40 }
pmoscPortbNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortbDdmWarning, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port B Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOSC Port B Not Urgent ON"}
--&MATCH { pmoscAlmPortbDdmWarning "on", pmosctrapBoardNumber "$2"}
--&MESG "DDM Warning disappears on Port B of PMOSC in slot $2 ($A)"
DESCRIPTION "Not urgent Port B default disappeared"
::= { pmosctraps 41 }
pmoscPortbUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortbDdmAlm, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port B Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pmoscAlmPortbDdmAlm "on", pmosctrapBoardNumber "$2"}
--&MESG "DDM Alarms appears on Port B of PMOSC in slot $2 ($A)"
DESCRIPTION "Urgent Port B default is activated"
::= { pmosctraps 42 }
pmoscPortbUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortbDdmAlm, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port B Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOSC Port B Urgent ON"}
--&MATCH { pmoscAlmPortbDdmAlm "on", pmosctrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on Port B of PMOSC in slot $2 ($A)"
DESCRIPTION "Urgent Port B default disappeared"
::= { pmosctraps 43 }
pmoscPortbCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortbFail, pmoscAlmPortbHwFail, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port B Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmoscAlmPortbFail "on", pmoscAlmPortbHwFail "*", pmosctrapBoardNumber "$3"}
--&MESG "Port B Down on PMOSC in Slot $3 ($A)"
--&FILTNAME "PMOSC Port B HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoscAlmPortbFail "*", pmoscAlmPortbHwFail "on", pmosctrapBoardNumber "$3"}
--&MESG "Port B Down on PMOSC in Slot $3 ($A)"
DESCRIPTION "Critical Port B default is activated"
::= { pmosctraps 44 }
pmoscPortbCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmoscAlmPortbFail, pmoscAlmPortbHwFail, pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Port B Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMOSC Port B Fail ON" }
--&MATCH { pmoscAlmPortbFail "on", pmoscAlmPortbHwFail "*", pmosctrapBoardNumber "$3"}
--&MESG "Port B Up on PMOSC in Slot $3 ($A)"
--&FILTNAME "PMOSC Port B HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoscAlmPortbFail "*", pmoscAlmPortbHwFail "on", pmosctrapBoardNumber "$3"}
--&MESG "Port B Up on PMOSC in Slot $3 ($A)"
DESCRIPTION "Critical Port B default disappeared"
::= { pmosctraps 45 }
--- *****************************************************
--- HW TRAPS
--- *****************************************************
pmoscPowerTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoscAlmDefFuseB, pmoscAlmDefFuseA , pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Fuse A Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmoscAlmDefFuseB "*", pmoscAlmDefFuseA "on", pmosctrapBoardNumber "$3"}
--&MESG "Power Input A Fail on PMOSC in Slot $3 ($A)"
--&FILTNAME "PMOSC Fuse B Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmoscAlmDefFuseB "on", pmoscAlmDefFuseA "*", pmosctrapBoardNumber "$3"}
--&MESG "Power Input B Fail on PMOSC in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default is activated"
::= { pmosctraps 50 }
pmoscPowerTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoscAlmDefFuseB, pmoscAlmDefFuseA , pmosctrapBoardNumber}
STATUS current
--&FILTNAME "PMOSC Fuse A&B Fail OFF"
--&ACTIONS { log, normal}
--&CLEARS { "PMOSC Fuse A Fail ON", "PMOSC Fuse B Fail ON" }
--&MATCH { pmoscAlmDefFuseB "on", pmoscAlmDefFuseA "on", pmosctrapBoardNumber "$3"}
--&MESG "Power Inputs A and B Present on PMOSC in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default disappeared"
::= { pmosctraps 51 }
END